PU 411_012_00 XxA Instruction Manual
User Manual:
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
EN PIC-01 Power Supply Instruction Manual PIC120.241C PIC120.242C PIC240.241C PIC480.241C AC 200-240V / DC 24-28V 5A AC 200-240V / DC 24-28V 5A AC 200-240V / DC 24-28V 10A AC 200-240V / DC 24-28V 20A Before operating the power supply, read this manual thoroughly and retain it for future reference! This device may only be installed and put into operation by qualified personnel. If damage or malfunction should occur during operation, immediately turn power off and send unit to the factory for inspection. The unit does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. This power supply is designed for installation in an enclosure and is intended for general use such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in equipment, where malfunction may cause severe personal injury or threaten human life. Risk of electrical shock, fire, personal injury or death: (1) (2) (3) (4) (5) (6) (7) (8) Do not use the power supply without proper grounding (Protective Earth). Turn power off before working on the device. Protect against inadvertent re-powering. Make sure that the wiring is correct by following all local and national codes. Do not modify or repair the unit. The unit does not contain serviceable parts. Do not open the unit as high voltages are present inside. Use caution to prevent any foreign objects from entering the housing. Do not use in wet locations or in areas where moisture or condensation can be expected. Do not touch during power-on, and immediately after power-off. Hot surfaces may cause burns. Installation Notes - Install the device on a DIN-rail according to EN 60715 with the input terminals on the bottom of the unit. - Do not obstruct air flow as the unit is convection cooled. Ventilation grid must be kept free of any obstructions (min. 40mm on top, 20mm on the bottom, 5mm left and right side). - Do not place heat sources adjacent to the power supply. - Do not use the device in pollution degree 3 environments. - Do not use the device in parallel connection. - The unit is tested and approved for branch circuits up to 30A (UL), 32A (IEC) without additional protection device. If an external fuse is utilized, do not use breakers smaller than 16A B- or 10A C-Characteristic (for PIC240) and not smaller than 10A B- or 6A C-Characteristic (for PIC120, PIC480) to avoid nuisance tripping. - Maximum surrounding air temperature: 70°C / 158°F. - For use in CSA C22.2 No 107 areas: Provide an output disconnecting means and use only in controlled environments. CE Declaration The CE mark is in conformance with the EMC directive and the low-voltage directive (LVD). Headquarters: PULS GmbH, Elektrastr. 6, 81925 Munich, Germany Germany China France Austria +49 89 9278 0 +86 512 62881820 +33 478 668 941 +43 27 64 32 13 www.pulspower.de www.pulspower.cn www.pulspower.fr www.pulspower.at Singapore Switzerland U.K. U.S.A www.pulspower.com +65 6684 2310 +41 56 450 18 10 +44 1525 841001 +1 630 587 9780 www.pulspower.sg www.pulspower.ch www.pulspower.co.uk www.pulspower.us Technical Data 1) PIC120.241C PIC120.242C Output Voltage Output Current nom. nom. Output Power Output Ripple & Noise Voltage 2) Input Voltage Input Frequency Input Current Power Factor Input Inrush Current 3) Efficiency / Power Losses Operational Temperature Range 4) Output Derating Storage Temperature Range Terminals 5) Stranded / solid wire AWG Wire stripping length Tightening torque DC-OK Contact nom. max. nom. nom. typ. typ. typ. typ. nom. nom. nom. nom. nom. nom. nom. EMC Immunity Generic Standard EMC Emission Generic Standard Radiated Emission Conducted Emission Harmonic Input Current Dimensions (WxHxD, without DIN-rail) nom. Weight max. PIC240.241C PIC480.241C DC 24-28V DC 24-28V DC 24-28V 5A at 24V, 10A at 24V, 20A at 24V, 4.3A at 28V 8.6A at 28V 17.1A at 28V 120W 240W 480W 100mVpp 100mVpp 100mVpp ±10% ±10% AC 200-240V AC 200-240V ±10% AC 200-240V 50-60Hz ±6% 50-60Hz ±6% 50-60Hz ±6% 1.1A 2.2A 2.2A 0.54 0.52 0.99 28A peak 48A peak 26A peak 90.5% / 12.6W 91.4% / 22.6W 95.7% / 21.6W -10°C - +70°C -10°C - +70°C -10°C - +70°C 3W/°C (+55°C - +70°C) 6W/°C (+55°C - +70°C) 8W/°C (+55 - +70°C) -40°C - +85°C -40°C - +85°C -40°C - +85°C max. 4mm2/ 6mm2 max. 4mm2/ 6mm2 max. 4mm2/ 6mm2 20-10AWG 20-10AWG 20-10AWG 7mm, 0.28inch 7mm, 0.28inch 7mm, 0.28inch 1Nm, 9lb.in 1Nm, 9lb.in 1Nm, 9lb.in PIC120.241C: Yes 6) Yes 6) Yes 6) PIC120.242C: No IEC 61000-6-1/ -6-2 IEC 61000-6-1/ -6-2 IEC 61000-6-1/ -6-2 IEC 61000-6-3 /-6-4 IEC 61000-6-4 IEC 61000-6-3 /-6-4 EN 55011/22 Class B EN 55011/22 Class B EN 55011/22 Class B EN 55011/22 Class B EN 55011/22 Class B EN 55011/22 Class B IEC 61000-3-2 Class A - IEC 61000-3-2 Class A 39x124x124mm 49x124x124mm 49x124x124mm 350g, 0.77lb 550g, 1.2lb 620g, 1.37lb 1) 2) 3) 4) 5) All parameters are specified at 230Vac, nominal output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 50-Ohm measurement, bandwidth 20MHz At 230Vac, 40°C ambient and cold start. The input inrush current is limited by a NTC and is temperature dependent. The operational temperature range equals the surrounding air temperature measured 2cm below the unit. Use appropriate copper cables, that are designed for a minimum operating temperature of 75°C for ambient temperatures up to 55°C and 90°C for ambient temperatures up to 70°C. Follow national installation codes and regulations! Ensure that all strands of a stranded wire enter the terminal. 6) Contact ratings: 60Vdc 0.3A; 30Vdc 1A; 30Vac, 0.5A; resistive load, min. current 1mA. PU-411.012.00-xxA The information presented in this document is believed to be accurate and may change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : zy Title : Microsoft Word - PU-411_012_00-xxA.doc Create Date : 2016:12:12 11:06:52+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2016:12:12 11:06:52+01:00 Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:d1265984-b4a4-449f-99fb-ea1bfa928fa6 Instance ID : uuid:808b4dfb-a0ce-490a-95b9-93169108b4f2 Page Count : 2 Author : zyEXIF Metadata provided by EXIF.tools