PU 411_012_00 XxA Instruction Manual
User Manual:
Open the PDF directly: View PDF .
Page Count: 2
EN PIC-01
Power Supply
Instruction Manual
PIC120.241C
PIC120.242C
PIC240.241C
PIC480.241C
AC 200-240V / DC 24-28V 5A
AC 200-240V / DC 24-28V 5A
AC 200-240V / DC 24-28V 10A
AC 200-240V / DC 24-28V 20A
Before operating the power supply, read this manual thoroughly and retain it for future reference! This device may only be
installed and put into operation by qualified personnel. If damage or malfunction should occur during operation,
immediately turn power off and send unit to the factory for inspection. The unit does not contain serviceable parts. The
tripping of an internal fuse is caused by an internal defect.
This power supply is designed for installation in an enclosure and is intended for general use such as in industrial control,
office, communication, and instrumentation equipment. Do not use this device in equipment, where malfunction may
cause severe personal injury or threaten human life.
Risk of electrical shock, fire, personal injury or death:
(1) Do not use the power supply without proper grounding (Protective Earth).
(2) Turn power off before working on the device. Protect against inadvertent re-powering.
(3) Make sure that the wiring is correct by following all local and national codes.
(4) Do not modify or repair the unit. The unit does not contain serviceable parts.
(5) Do not open the unit as high voltages are present inside.
(6) Use caution to prevent any foreign objects from entering the housing.
(7) Do not use in wet locations or in areas where moisture or condensation can be expected.
(8) Do not touch during power-on, and immediately after power-off. Hot surfaces may cause burns.
Installation Notes
- Install the device on a DIN-rail according to EN 60715 with the input terminals on the bottom of the unit.
- Do not obstruct air flow as the unit is convection cooled.
Ventilation grid must be kept free of any obstructions (min. 40mm on top, 20mm on the bottom, 5mm left and right side).
- Do not place heat sources adjacent to the power supply.
- Do not use the device in pollution degree 3 environments.
- Do not use the device in parallel connection.
- The unit is tested and approved for branch circuits up to 30A (UL), 32A (IEC) without additional protection device.
If an external fuse is utilized, do not use breakers smaller than 16A B- or 10A C-Characteristic (for PIC240) and not
smaller than 10A B- or 6A C-Characteristic (for PIC120, PIC480) to avoid nuisance tripping.
- Maximum surrounding air temperature: 70°C / 158°F.
- For use in CSA C22.2 No 107 areas: Provide an output disconnecting means and use only in controlled environments.
CE Declaration
The CE mark is in conformance with the EMC directive and the low-voltage directive (LVD).
Headquarters: PULS GmbH, Elektrastr. 6, 81925 Munich, Germany www.pulspower.com
Germany +49 89 9278 0 www.pulspower.de
China +86 512 62881820 www.pulspower.cn
France +33 478 668 941 www.pulspower.fr
Austria +43 27 64 32 13 www.pulspower.at
Singapore +65 6684 2310 www.pulspower.sg
Switzerland +41 56 450 18 10 www.pulspower.ch
U.K. +44 1525 841001 www.pulspower.co.uk
U.S.A +1 630 587 9780 www.pulspower.us
Technical Data 1) PIC120.241C
PIC120.242C
PIC240.241C PIC480.241C
Output Voltage nom. DC 24-28V DC 24-28V DC 24-28V
Output Current nom. 5A at 24V,
4.3A at 28V
10A at 24V,
8.6A at 28V
20A at 24V,
17.1A at 28V
Output Power nom. 120W 240W 480W
Output Ripple & Noise Voltage 2) max. 100mVpp 100mVpp 100mVpp
Input Voltage nom. AC 200-240V ±10% AC 200-240V ±10% AC 200-240V ±10%
Input Frequency nom. 50-60Hz ±6% 50-60Hz ±6% 50-60Hz ±6%
Input Current typ. 1.1A 2.2A 2.2A
Power Factor typ. 0.54 0.52 0.99
Input Inrush Current 3) typ. 28A peak 48A peak 26A peak
Efficiency / Power Losses typ. 90.5%
/
12.6W 91.4% / 22.6W 95.7% / 21.6W
Operational Temperature Range 4) nom. -10°C - +70°C -10°C - +70°C -10°C - +70°C
Output Derating nom. 3W/°C (+55°C - +70°C) 6W/°C (+55°C - +70°C) 8W/°C (+55 - +70°C)
Storage Temperature Range nom. -40°C - +85°C -40°C - +85°C -40°C - +85°C
Terminals 5) Stranded / solid wire
AWG
Wire stripping length
Tightening torque
nom.
nom.
nom.
nom.
max. 4mm2/ 6mm2
20-10AWG
7mm, 0.28inch
1Nm, 9lb.in
max. 4mm2/ 6mm2
20-10AWG
7mm, 0.28inch
1Nm, 9lb.in
max. 4mm2/ 6mm2
20-10AWG
7mm, 0.28inch
1Nm, 9lb.in
DC-OK Contact PIC120.241C: Yes 6)
PIC120.242C: No
Yes 6) Yes 6)
EMC Immunity Generic Standard IEC 61000-6-1/ -6-2 IEC 61000-6-1/ -6-2 IEC 61000-6-1/ -6-2
EMC Emission Generic Standard
Radiated Emission
Conducted Emission
Harmonic Input Current
IEC 61000-6-3 /-6-4
EN 55011/22 Class B
EN 55011/22 Class B
IEC 61000-3-2 Class A
IEC 61000-6-4
EN 55011/22 Class B
EN 55011/22 Class B
-
IEC 61000-6-3 /-6-4
EN 55011/22 Class B
EN 55011/22 Class B
IEC 61000-3-2 Class A
Dimensions (WxHxD, without DIN-rail) nom. 39x124x124mm 49x124x124mm 49x124x124mm
Weight max. 350g, 0.77lb 550g, 1.2lb 620g, 1.37lb
1) All parameters are specified at 230Vac, nominal output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
2) 50-Ohm measurement, bandwidth 20MHz
3) At 230Vac, 40°C ambient and cold start. The input inrush current is limited by a NTC and is temperature dependent.
4) The operational temperature range equals the surrounding air temperature measured 2cm below the unit.
5) Use appropriate copper cables, that are designed for a minimum operating temperature of 75°C for ambient temperatures up to 55°C and
90°C for ambient temperatures up to 70°C.
Follow national installation codes and regulations! Ensure that all strands of a stranded wire enter the terminal.
6) Contact ratings: 60Vdc 0.3A; 30Vdc 1A; 30Vac, 0.5A; resistive load, min. current 1mA.
PU-411.012.00-xxA The information presented in this document is believed to be accurate and may change without notice.