C John Deere 244 J Install

User Manual: John Deere 244 J Install

Open the PDF directly: View PDF PDF.
Page Count: 5

Weighlog 100/200 Installation
Supplement
This supplement will show some of the locations for mounting the equipment included in this scale system.
The installations shown are not required locations they are only intended as a guide.
John Deere 244 J
Head Unit Mounting
The customer mounted the head unit to the dash panel. The back side of the dash has
a reinforcement plate to make the mount solid.
Weighlog 100/200 Installation
Supplement
John Deere 244 J
Load Sensor Mounting
The Pressure Sensor was mounted to the plate towards the front of the machine with the bracket supplied.
Note the loom installed on the hoses to help prevent premature wear.
Load Sensor Installation
This installation was made by using the ORFS Fitting supplied in the kit. The location is at the end
of the hoses coming from the lift cylinder.
Weighlog 100/200 Installation
Supplement
John Deere 244 J
Reference/Direction Sensor
The magnet was mounted using the bracket supplied and bolted to the inside of
the lift arm by drilling and using the flange plate on the lift arm.
Reference/Direction Sensor
The Ref/Dir sensor mounting bracket for this installation was bolted to the plate by drilling 2 holes.
Be sure the mounting will not interfere with the lift arm operation.
Weighlog 100/200 Installation
Supplement
John Deere 244 J
Remote Enter Switch
The remote enter switch needs to be mounted to allow easy access by the operator.
The cable will be routed to the floor and under the mat to the junction box.
Junction Box Mounting
The Junction box was mounted to the right-hand side of the dash panel as shown.
Weighlog 100/200 Installation
Supplement
John Deere 244 J
Wiring and Connections
The cables sensor cables will be routed through the center of the machine to the junction box.
Use the black loom to cover the cables to help prevent premature failure. Use caution when routing cables
through the center piviot of the machine.
Wiring and Connections
Switched power can be found under the panel shown and the cable routed under
the floor mat to the junction box location.