LBF Sales Brochure

User Manual: LBF Sales Brochure

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadLBF Sales Brochure
Open PDF In BrowserView PDF
the LBF range
Our high efficiency gas fired
balanced flue storage
water heaters

Technical

Specification
LBF range
Water Heater Model
Nominal Input (Net)
Nominal Input (Gross)
Gas Flow Rate
(Natural Gas)
Nominal Output
Efficiency
(Part L2 Gross CV)
NOx Emission,
(corrected to 0% O2)
NOx Emission,
(corrected to 0% O2)
Storage Losses

kW
kW
m3/hr
kW
%

High output LBF range

LBF-80

LBF-120

LBF-150

LBF-180

LBF-220

LBF-300

LBF-400

160-LBF

240-LBF

320-LBF

382-LBF

5
5.6

5
5.6

18
20

19
21.1

28.5
31.7

31
34.5

31
34.5

44
48.9

66
73.3

88
97.7

106
117.7

0.53
4.7

0.53
4.7

1.9
16.7

2
17.5

3.01
25.8

3.28
28

3.28
28

4.54
38.7

6.8
59.4

8.4
78.3

10.93
93.3

79.63

79.63

76.26

76.93

77.21

77.06

77.06

78.47

80.25

79.48

78.63

84

84

113

95

68

65

65

171

146

172

173

148

148

198

168

120

115

115

301

257

303

305

0.0884
87
76
72

0.0633
87
76
72

0.0536
298
262
256

0.0472
317
279
268

0.0409
477
420
395

0.0343
518
456
428

0.0298
518
456
428

0.0326
749
659
592

0.0326
1149
1011
909

0.0326
1517
1335
1198

0.0292
1808
1591
1428

Recovery rate @ 44o C
Recovery rate @ 50o C
Recovery rate @ 56o C

ppm
mg/
kWh
kWh
/I/day
l/hr
l/hr
l/hr

Dimensions (Height)*
Dimensions (Width)
Dimensions (Depth)

mm
mm
mm

1040
450
460

1400
450
460

1925
520
520

2125
520
520

1665
720
720

2015
720
720

2365
720
720

1780
720
1140

1780
720
1140

1780
720
1140

2005
720
1140

Water Content
Weight (Empty)
Weight (Full)
Flow Connection
Return Connection
Gas Connection
Flue Diameter
(Concentric)
Flue Diameter
(Twin-pipe)
Flue Diameter
(Conventional)
Electrical Requirements
Power Consumption

Litre
Kgs
Kgs
BSP
BSP
BSP

75
49
124
½”
½”
3/8”

115
74
189
½”
½”
3/8”

145
100
245
¾”
¾”
½”

175
110
195
¾”
¾”
½”

220
202
422
1 ¼”
1 ¼”
½”

300
245
545
1 ¼”
1 ¼”
½”

400
286
686
1 ¼”
1 ¼”
½”

276
340
616
1 ½”
1 ½”
¾”

276
340
616
1 ½”
1 ½”
¾”

276
345
641
1 ½”
1 ½”
¾”

350
381
727
1 ½”
1 ½”
¾”

mm

38/60

38/60

60/100

60/100

60/100

60/100

60/100

100/150

100/150

130/200

130/200

mm

38/60

38/60

80/80

80/80

80/80

80/80

80/80

n/a

n/a

n/a

n/a

mm

n/a

n/a

n/a

n/a

n/a

100

100

130

130

W

26

26

62

62

n/a
n/a
230V/1PH/50HZ
62
62

62

460

460

460

460

CO2 - Flue Gas
Maximum Flue Gas
Temperature
Waterside Pressure
Loss @10o C
Max. Outlet Temp.
Maximum
Working Pressure

%

6

6

6

6

6

6

6

6

6

6

6

C

99

89

196

177

200

194

168

220

220

220

220

kPa
C

77

77

80

80

not applicable
80
80

80

82

82

82

82

6

6

6

6

6

10.3

10.3

10.3

10.3

o

o

bar

Note:* LBF range - dimension to top of flue fan housing
High output LBF range - dimension to top of flue spigot

6

6

Lochinvar

LBF balanced flue water heaters
LBF room sealed balanced flue water heaters offer all the advantages of Lochinvar’s
traditional Knight and Charger high efficiency gas fired storage water heaters, but
with the added benefit of having a concentric balanced flue. LBF water heaters draw
air for combustion directly from outside, ensuring safe and reliable operation and
offering significant installation cost savings when compared with conventionally
flued units. They are particularly suitable for use in areas of negative pressure such
as, for example, kitchens, eliminating potential 'spillage' that may be created where
extractor fans are installed.
Lochinvar LBF water heaters feature baffled
flueways for maximum heat transfer. Custom
designed steel baffles are suspended within
the flueways increasing the amount of heat
transferred from the products of combustion
to the water.

Models
LBF-80 | LBF-120

These combustion products are taken into
a common header and discharged via the
fan-assisted, concentric balanced flue,
either horizontally or vertically.

These two models are extremely compact,
wall mounted and have a flue diameter of
only 60mm.
Storage capacities are 75 litres and 115 litres
respectively and both have a recovery rate of
76 litres/hour based upon a temperature
rise of 50o C

All models can be installed using either
horizontal or vertical flue assemblies. A basic
flue kit is available from Lochinvar, as well as
additional flue components including bends
and flue pipe.

The LBF80 and LBF120 are particularly
suitable for smaller commercial and
industrial applications providing low
volume, instant hot water.

All models feature automatic ignition as
standard and the facility to interface with
building management systems is also available.
The vitreous-enamelled steel tank is insulated in
expanded polyurethane to reduce heat losses.

LBF-80 and LBF-120 water heaters

Features
• Wall mounted-saving on valuable

With storage capacities from 75 litres
to 400 litres and recovery rates from 76 to
1591 litres/hour based upon a temperature
rise of 50o C Lochinvar LBF water heaters offer
a highly efficient solution for a wide variety
of commercial and industrial applications.

•
•
•
•
•

H

floor space
Automatic ignition
Stainless steel burner
Room sealed fan assisted flue
A wide range of ancillaries offering installation flexibility
(refer to back page for details).
Available for Natural Gas or LPG

F

A
E
B
250
D

G

Top view

P

Front view

J

C

K

Models
LBF-150 | LBF-180
LBF-220 | LBF-300 | LBF-400
These five models offer storage capacities
from 145 to 400 litres and recovery rates
from 262 to 456 litres/hour based upon
a temperature rise of 50o C.
LBF water heaters are very compact,
with models LBF150 and LBF180 having
a footprint of only 520mm x 520mm. This
along with the flueing options with all five
models provides increased siting flexibility.
Concentric flue runs of up to 3m horizontal
or 2m vertical are possible and up to
6m horizontal or vertical if using a twin
pipe assembly.
Additional flue components
are available as ancillary options.

LBF-150 and LBF-180
water heaters
LBF-220, LBF-300 and LBF-400 water heaters

Features
•
•
•
•
•

Automatic ignition
Stainless steel burner
Room sealed fan assisted flue
A wide range of ancillaries - offering
installation flexibility
(refer to back page for details)
Available for Natural Gas or LPG

I
H

D

C

G

Top view

LBF-80 LBF-120

N
Cold inlet

Gas
inlet

LBF water heaters - dimensions (mm)
Model

Hot outlet

B

LBF-150 LBF-180 LBF-220 LBF-300 LBF-400

A

1040

1400

1925

2125

1665

2015

2365

B

895

1255

1700

1900

1350

1700

2050

C

450

450

520

520

720

720

720

D

460

460

520

520

720

720

720

E

895

1255

1750

1950

1495

1840

2190

F

60

60

100

100

100

100

100

G

500

500

500

500

500

500

500

H

200

200

200

200

200

200

200

I

n/a

n/a

50

50

50

50

50

J

50

50

200

200

50

50

50

K

50

50

300

300

200

200

200

L

n/a

n/a

420

420

470

470

470

M

n/a

n/a

390

395

565

565

565

N

n/a

n/a

1620

1825

1300

1655

2000

O

n/a

n/a

460

465

570

570

570

P

500

500

n/a

n/a

n/a

n/a

n/a

L

M

RH side view
F

A

B
E

50
O

K

J

Front view

the LBF range

| Our high efficiency gas fired balanced flue storage water heaters

High output LBF range
Models 160-LBF | 240-LBF
320-LBF | 382-LBF
E
I

The high output LBF range comprises four
models with storage capacities of 276 or
350 litres. Recovery rates from 659 to 1591
litres/hour based upon a temperature rise
of 50o C are achievable from these highly
efficient water heaters.

Features
• Automatic ignition
• Stainless steel burner
• Room sealed concentric
•

Concentric flue runs of up to 6m horizontal or
7m vertical are possible providing increased
siting flexibility and installation cost savings
when compared with conventionally flued units

•

High output LBF water heaters dimensions (mm)
Model

H

C

L

M

fan assisted flue
A wide range of
ancillaries - offering
installation flexibility
(refer to back page
for details)
Available for
Natural Gas or LPG

I

H

F

Top view

160-LBF 240-LBF 320-LBF 382-LBF

A

1780

1780

1780

2005

B

720

720

720

720

C

1140

1140

1140

1140

D

2055

2055

1955

2180

E

150

150

200

200

F

730

730

730

730

G

1168

1168

1168

1168

H

305

305

305

305

I

305

305

305

305

J

355

355

355

355

K

130

130

130

130

L

500

500

500

500

M

825

825

825

825

N

1307

1307

1307

1535

O

530

530

530

530

G

Hot outlet
Gas inlet

LBF range
Each 90o bend and 45o bend is
equivalent to 1m flue distance
High output LBF range
Each 90o bend is equivalent to 1m flue
distance and each 45o bend is equivalent
to 0.5m flue distance.

D
A

Cold inlet
N

O
J

B

High output LBF
water heater

Flue installation
When calculating the length
of your flue installation the
following should be taken into
consideration;

K

Front view

LBF water heater
ancillary options
• Flame failure relay
• Unvented system kits
• Direct storage vessels
• Correx® non sacrificial electrical anodes
• Horizontal or vertical room sealed
concentric flue assemblies
• Room sealed twin pipe flue assemblies
(not available on high output LBF models)
• De-stratification pump kit

Drawings
Dimensional drawings for all models are
available as hard copy or CAD files, that can be
downloaded from our website
www.lochinvar.ltd.uk.

Lochinvar Ltd
7 Lombard Way
The MXL Centre
Banbury
Oxon
OX16 4TJ
Tel: +44 (0) 1295 269981
Fax: +44 (0) 1295 271640
Email: sales@lochinvar.ltd.uk

www.lochinvar.ltd.uk

Dakota Hotel, Nottingham
Hot water for the 92 bedroom hotel supplied
by 3 x high output LBF water heaters.

Morrisons Supermarkets

Designed & produced by Cafécreate

Hot water supplied by our LBF and high
output LBF range of water heaters.

Lochinvar Limited reserve the right to
change specifications without prior notice.
cc6841LO | LBF | November 2009



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Author                          : Mark Dodgson
Create Date                     : 2009:11:18 14:18:02Z
Modify Date                     : 2009:11:23 13:05:02Z
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : Layout 1
Creator                         : Mark Dodgson
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Creator Tool                    : QuarkXPress(R) 7.31
Metadata Date                   : 2009:11:23 13:05:02Z
Document ID                     : uuid:b7029c2f-34f3-4f6e-b97b-7b74f6719aa8
Instance ID                     : uuid:748b5d6f-f4d3-48f6-b816-18aa829e4b05
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu