ISO 14001 ISO 9001 Service Manual LC125 Meatwell with LDU15 Controller (Feb ‘04 till July ‘09) then AT1-5 Controller (July ‘09 onwards) Re-Issued October 2010 Original Aug 09 Contents Manual Information & Health & Safety Notes Environmental Management Policy Disposal Requirements Important Controller Change Information Description, Maintenance & Technical Information AT1-5 Controller Information Alarms and Warnings Probe Setting, Parameters & Adjustments AT1-5 Wiring Diagram LDU15 Controller Information Parameters & Electrical Connections LDU15 Wiring Diagram Troubleshooting & Notes 1 2 2 3 3 3 to 4 4 to 5 5 to 6 7 8 9 10 11 to 13 Service Manual Information The products and all information in this manual are subject to change without prior notice. We assume by the information given that the person(s) working on these refrigeration units are fully trained and skilled in all aspects of their workings. Also that they will use the appropriate safety equipment and take or meet precautions where required. The service manual does not cover information on every variation of this unit; neither does it cover the installation or every possible operating or maintenance instruction for the units. Health & Safety Warnings and Information Make sure the power supply is turned off before making any electrical repairs. To minimise shock and fire hazards, please do not plug or unplug the unit with wet hands. During maintenance and cleaning, please unplug the unit where required. Care must be taken when handling or working on the unit as sharp edges may cause personal injury, we recommend the wearing of suitable PPE. Ensure the correct moving and lifting procedures are used when relocating a unit. Do NOT use abrasive cleaning products, only those that are recommended. Never scour any parts of the refrigerator. Scouring pads or chemicals may cause damage by scratching or dulling polished surface finishes. Failure to keep the condenser clean may cause premature failure of the motor/compressor which will NOT be covered under warranty policy. Do NOT touch the cold surfaces in the freezer compartment. Particularly when hands are damp or wet, skin may adhere to these extremely cold surfaces and cause frostbite. Please ensure the appropriate use of safety aids or Personnel Protective Equipment (PPE) are used for you own safety. 1 Environmental Management Policy for Service Manuals and Duets. Product Support and Installation Contractors Foster Refrigerator recognises that its activities, products and services can have an adverse impact upon the environment. The organisation is committed to implementing systems and controls to manage, reduce and eliminate its adverse environmental impacts wherever possible, and has formulated an Environmental Policy outlining our core aims. A copy of the Environmental Policy is available to all contractors and suppliers upon request. The organisation is committed to working with suppliers and contractors where their activities have the potential to impact upon the environment. To achieve the aims stated in the Environmental Policy we require that all suppliers and contractors operate in compliance with the law and are committed to best practice in environmental management. Product Support and Installation contractors are required to: 1. Ensure that wherever possible waste is removed from the client‟s site, where arrangements are in place all waste should be returned to Foster Refrigerator‟s premises. In certain circumstances waste may be disposed of on the client‟s site; if permission is given, if the client has arrangements in place for the type of waste. 2. If arranging for the disposal of your waste, handle, store and dispose of it in such a way as to prevent its escape into the environment, harm to human health, and to ensure the compliance with the environmental law. Guidance is available from the Environment Agency on how to comply with the waste management „duty of care‟. 3. The following waste must be stored of separately from other wastes, as they are hazardous to the environment: refrigerants, polyurethane foam, and oils. 4. When arranging for disposal of waste, ensure a waste transfer note or consignment note is completed as appropriate. Ensure that all waste is correctly described on the waste note and include the appropriate six-digit code from the European Waste Catalogue. Your waste contractor or Foster can provide further information if necessary. 5. Ensure that all waste is removed by a registered waste carrier, a carrier in possession of a waste management licence, or a carrier holding an appropriate exemption. Ensure the person receiving the waste at its ultimate destination is in receipt of a waste management licence or valid exemption. 6. Handle and store refrigerants in such a way as to prevent their emission to atmosphere, and ensure they are disposed of safely and in accordance with environmental law. 7. Make arrangements to ensure all staff who handle refrigerants do so at a level of competence consistent with the City Guilds 2078 Handling Refrigerants qualification or equivalent qualification. 8. Ensure all liquid substances are securely stored to prevent leaks and spill, and are not disposed of to storm drains, foul drain, or surface water to soil. Disposal Requirements If not disposed of properly all refrigerators have components that can be harmful to the environment. All old refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance with national laws and regulations. 2 IMPORTANT CONTROLLER CHANGE INFORMATION AS OF FEB 2004 THIS UNIT HAD THE LDU15 (00-555357) CONTROLLER. ND AS OF 22 JULY 2009 THIS HAS NOW BEEN REPLACED WITH AN AT1-5 (00-556223) CONTROLLER. PLEASE NOTE THAT IF YOU ARE REPLACING THE LDU15 CONTROLLER TO THE NEW AT1-5 CONTROLLER YOU WILL ALSO HAVE TO REPLACE THE AIR PROBE WITH SN4K150P1 (00-556187). This manual provides information on both controllers. Meatwell Description This is a one piece foam shell with a skin evaporator and bottom mount condensing system. The condensing system uses R134a refrigerant. The cabinet is designed for the storage of frozen products and is top loading. It is fitted with four 60mm castors, rubber bumpers to each corner and a front smash bar is available as an added option (but fitted as standard to Burger King units). Routine Maintenance In order to keep the unit operating reliably and efficiently periodical cleaning of the condenser is necessary. (The frequency being determined by site conditions) This operation is to be carried out with the unit turned OFF. We advise the use of a soft long haired brush on the outside of the condenser taking care not to damage the fins. Warning: Condenser fins have sharp edges so care must be taken to avoid injury Technical Information Temperature Set Point Refrigerant Refrigerant Charge Capillary Power Supply -21ºC R134A 180grms 4.4mts x 042 230/50/1 Controller Information for models using the LAE AT1-5BS6E-FS1 Controller (00-556223) Operation Guidelines – Please note the unit has a rest time of 10mins before start up will begin. Initial Start Up Start Up & self Test: The indication is only displayed during the first three seconds following the mains electrical power being applied to the unit. During this period the controller performs a self-check. Once the self-check has been completed OFF will be displayed. Press and hold for three seconds. The unit will start and the air temperature will be displayed. Check temperature set point. To make adjustments to the set point it is necessary to access the parameter and alter SPL and SPH accordingly. 3 Check set point by pressing the To increase set point press button + until required temperature is displayed. To decrease set point press + until required temperature is displayed. Exit from set up occurs after 10 seconds if no button is pressed. Manual Defrost To initiate a manual defrost press and hold dEF will be displayed release . . On completion of the defrost REC will be displayed until the cabinet temperature is achieved and then it will revert to displaying the normal cabinet temperature. Set Unit to Standby Press , in the display OFF will show This indication is displayed while the unit is not operating but with mains power applied to the unit. This mode may be used for internal cleaning regimes and short periods when the unit is not required. For extended periods of inactivity the mains supply should be isolated. Alarm and Warnings High Temperature Alarm HI Will be displayed. The alarm will sound but can be silenced by pressing any of the buttons, however it will return after the pre-set designated period. The unit will return to normal operating temperature and will automatically cancel the alarm. Possible Causes: The evaporator fan is not working; there is a restricted airflow through the air duct. The evaporator is iced up or the compressor is not working. Low Temperature Alarm. LO Will be displayed. The alarm will sound but can be silenced by pressing any of the buttons, however it will return after the pre-set designated period. The unit will return to normal operating temperature and will automatically cancel the alarm Possible Causes: Controller is faulty (not switching compressor off). The compressors secondary relay will not deenergise (low temperature models). Air Temperature Probe Failure E1 Will be displayed. The alarm will sound but can be silenced by pressing any button. There is no further action that can be taken by the user in this instance. During this period the unit will continue to operate but have a reduced performance. Action: Replace Probe. Information Menu Pressing and releasing activates the information menu. From this menu you can display the temperature relating to T1 (air probe), T2 (evaporator probe, if fitted) and T3 (condenser probe, if fitted). The maximum temperature (THI) and the minimum temperature (TLO) the cabinet has achieved since it was last re-set. The total operating time of the condenser (CND) since it was last cleaned, and the keyboard status (LOC). The information to be displayed can be selected sequentially by pressing 4 repeatedly or scrolling through the menu using the Once selected press or buttons. to display the value. Exit from the info menu by pressing pressed. or it will automatically exit after 6 seconds if no buttons are To reset the temperature settings recorded in THI and TLO and the hours counted in CND, access the info menu press to display the value plus simultaneously for resetting to be completed. To check the LOC status scroll through to LOC, press to display status – YES to lock keys. – NO to leave keys accessible. NOTE: with the keys locked it is not possible to turn the unit OFF or ON or to check the set point. Parameter Setting and Adjustment It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained. The parameters are accessed by pressing the following keys in succession and keeping them pressed for 5 seconds. + After this period the first parameter ‘SCL’ will be displayed. Press button to pass from one parameter to the next and Press to display the value followed by Exit from set up is by pressing or button to go back. to change it. or automatic if no buttons are pressed for 30 seconds. Probe Identification The probe fitted to this controller is the 10k NTC type (LAE SN4K15P1, Part number 00-556187) with red letter identification. LAE NTC10K Temperature Resistance Table Temperature(°C) Temperature(°C) R-mid (K) -25 87.559 -5 -20 68.237 0 -15 53.65 5 -10 42.506 10 R-mid (K) 33.892 27.219 21.63 17.926 5 Temperature(°C) 15 20 25 30 R-mid (K) 14.674 12.081 10 8.315 LAE AT1-5BS6E-FS1 Controller Parameter List Mnem. SCL SPL SPH SP C-H HYS CRT CT1 CT2 CSD DFR DLI DTO DTY DDY ATM ALA(’R) AHA(‘R) ALR AHR ATD ADO ACC SB DS OAU INP OS1 T2 OS2 TLD SIM ADR Definition Readout Scale Minimum Set Point (1) Maximum Set Point (1) Set Point (1) Refrigeration / Heating Thermostat Hysteresis Minimum Compressor Rest Time Compressor Run with T1 Failure Compressor Stop With T1 Failure Compressor Stop Delay From Door Opening Defrost Frequency / 24h Defrost End Temperature Maximum Defrost Duration Defrost Type Defrost Display Control Alarm Threshold Control Low Temperature Alarm Threshold High Temperature Alarm Threshold Low Temperature Alarm Differential High Temperature Alarm Differential Alarm Temperature Delay Door Alarm Delay Condenser Cleaning Period Button 0/1 Enabling Door Switch Enabling AUX Output Control SN4 / ST1 T1 (air) Probe Offset T2 (evaporator) Probe Enabling T2 (evaporator) Probe Offset Delay for Minimum / Maximum Temperature Storage Display Slowdown Unit Peripheral Address 6 Min Max 1ºC ; 2 ºC ; F º -50 SPH SPL 120 SPL SPH REF HEA 1 100 0 30 0 30 0 30 0 30 0 24 -30 30 1 120 OFF; ELE; GAS 0 60 NON; ABS; REL -50 (-120) +120 (0) -50 (0) +120 (120) -12 0 0 12 0 120 0 30 0 52 YES NO YES NO NON;0-1:LGT;FAN;AL1 SN4; ST1 -125 125 YES NO -125 125 1 30 0 100 1 255 Default 2 -5 5 0 REF 3 3 3 6 1 3 6 20 ELE 10 ABS -50 120 30 5 0 YES NO LGT SN4 0 NO 0 5 0 1 Dim flag ºC ºC ºC flag ºK min min min min 1/24 ºC min Flag Min flag ºC/ ºK ºC/ ºK ºK ºK min min wks flag flag flag flag ºK flag ºK min exp exp Setting 2 ºC -21 -21 -21 REF 3 10 7 3 1 0 15 20 OFF 20 REL -25 -10 -5 5 90 5 0 YES NO NON SN4 0 NO 0 5 50 1 LC125 Wiring Diagram with the LAE AT1-5BS6E-FS1 Controller 7 Controller Information for models using the LDU 151E-BG Controller (00-555357) When the controller is switched on a single line appears on the display for 3 seconds to indicate the autotest period. After this period the air temperature measured by the T1 probe is displayed. It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained. lae LDU 15 Controller aux set aux Check temperature set point. Check set point by pressing the “set” button To increase set point press “set” + To decrease set point press “set” + Factory Temperature Set Point -21°C. Exit from set up occurs after 10 seconds if no button is pressed. Manual Defrost. To initiate a manual defrost press buttons and simultaneously. Controller Set Up. + “set” + The parameters are accessed by pressing the following keys in succession them pressed for 3 seconds. Access to the parameters has been achieved with the first parameter SCL being displayed. To pass from one parameter to the next press either the or key. To display the value press. “set” To change the value press “set” + to increase, or “set” + to decrease. Exit from set up by pressing “aux” or is automatic after 30 seconds if no buttons are pressed. Alarms and Warnings HI High Temperature Alarm LO Low Temperature Alarm E1 T1 Probe Failure DF Defrosting in Progress CLN Condenser 8 and keeping Parameters for Cabinets with the LDU15 1E-B Controller Display SCL SPL SPH SP HYS CRT CDC DFR DTO DDY ATL ATH ATD ACC OAU BAU OS1 SIM ADR LDU151E-B Default Values 2°C 05 01 03 3 10 20 4 20 1 -5 5 60 05 30 05 00 00 01 Parameter Readout Scale Minimum Temperature Set Point Maximum Temperature Set Point Effective Temperature Set Point Hysteresis Compressor Rest Time (minutes) Compressor Regulation with T1 Fail Defrosting Frequency (/24 hours) Defrosting Duration (minutes) Defrost Display Control Low Alarm Differential High Alarm Differential Temperature Alarm Delay (minutes) Condenser Clean Interval Auxiliary Output Mode of Operation Auxiliary Button Mode of Operation T1 Offset Display Slowdown Address LDU 151E-BG Electrical Connections DATA AUX T1 1 11 2 3 4 5 6 7 PWR 9 8 9 10 LC 125 2°C -25 -15 -21 +3 0 7 0 20 1 -10 10 90 0 NON NON 00 00 01 Wiring Diagram for Models Using the LDU15 Controller 10 Troubleshooting Problem Compressor will not start Possible Cause No voltage in socket Electrical conductor or wires may be cut Defective electrical component: thermostat, relay, thermal protector etc Replace defective component Measure ohmic resistance of main and auxiliary winding using ohmmeter. Compare with correct values Compressor stuck Change compressor Controller is set at a very cold position Controller does not disconnect the condensing unit Control contacts are stuck closed Defective or incorrect temperature control The temperature is not cold enough Use voltmeter to check Use ohmmeter to check for continuity Compressor motor has a winding open or shorted Temperature control contacts are open Incorrect wiring Fuse blown or circuit breaker tripped. Power cord unplugged Controller set too high Cabinet in defrost cycle The temperature is too cold Solution Repair or replace the contacts Check wiring diagram and correct Replace fuse or reset circuit breaker Plug in power cord. Set controller to lower temperature. Wait for defrost cycle to finish Set to warmer position and check if the compressor stops according to controllers operating range. Check the insulation of the thermostat. If problem persists, change the thermostat Change the control. Check amperage load Determine correct control and replace. Controller is set at a very warm position Adjust to colder setting Condenser is dirty Clean condenser The refrigerator has been placed at an inadequate location The unit must not be near stoves, walls that are exposed to the sun, or places that lack sufficient air flow. Compressor is inefficient or there is a high pressure due to the air in the system If there is air in the system, purge and recharge Iced up evaporator coil Restriction in system The refrigerator has been used improperly Check temperature control, refrigerant charge, and defrost mechanism. Remove all ice manually and start over. Locate exact point of restriction and correct The shelves must never be covered with any type of plastic or other material that will block the circulation of cold air within the refrigerator. Too many door openings Advise user to decrease if possible Excessive heat load placed in cabinet Advise user not to put in products that are too hot. 11 The refrigerator has been overcharged with the refrigerant gas The refrigerant gas is leaking The evaporator and/or condenser fans are not working Blocking air flow Fuse blown or circuit breaker tripped Electrical Shocks Noise Wires or electrical components are in direct contact with metallic parts. Check for appropriate insulation on the connections of each component. The refrigerator is not properly levelled Check if the noise goes away after you level the refrigerator The condenser is not fastened correctly. Copper tubing is in contact with metal The evaporator and/or condenser fans are loose Compressor has an internal noise Loose part(s) Extreme condensation inside the refrigerator Controller is set at a very cold position The outside environment‟s relative humidity is very high (over 75%) The refrigerator door wont shut completely The refrigerator had been placed at an inadequate location No illumination (Glass door models only) Check to see if condensation or ice crystals have formed on the suction line. If so, charge with the correct amount of gas. Find the location of gas leak in order to seal and replace the defective component. Change the drier. Perform a good vacuum and recharge unit. Check electrical connections and make sure that the fan blade isn‟t stuck. Replace the fan motor if it doesn‟t work. Re-arrange product to allow for proper air flow. Make sure there is at least four inches of clearance from evaporator. Replace fuse or reset circuit breaker. The light switch is “off” position False contact on the light switch, the fluorescent tube, or the ballast Light switch, ballast and/or fluorescent tube are damaged 12 While the compressor is working, check to see if metal parts are in contact with one another and/or if the screws that fasten the condenser are tightened. Check if the fans are securely fastened. Also, check if the fan blades are loose, broken or crooked. If so, change the faulty blade. If the noise persists after all other measures have been taken, it may be originating from the compressor. Locate and tighten loose part(s) Set the controller to a warmer position & check to see if compressor stops as should. This type of occurrence is caused by local climatic conditions and not by the refrigeration unit. Check the door and/or the magnetic gasket. Adjust the door hinges if needed; replace the gasket if broken. The unit must not be near sources that produce too much heat. Press the light switch to “on” position Inspect all connections Replace the damaged component. Condensing unit runs for long periods of time Excessive amount of warm product placed in cabinet Prolonged door opening or door ajar Door gasket(s) not sealing properly Advise user to leave adequate time for products to cool down Advise user to ensure doors are closed when not in use and to avoid opening doors for long periods of time. Ensure gaskets are snapped in completely. Remove gasket and wash with soap and water. Check condition of gasket & replace if necessary Dirty condenser coil Clean condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost. Make sure thermostat is not set too cold. Ensure that door gasket(s) are sealing properly. Select manual defrost and ensure system works. Notes 13 Foster European Operations France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com Germany Foster Refrigerator Gmbh, Tel: (49) 781 990 7840. Fax (49) 781 990 7844. Email: info@foster-gmbh.de Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU Tel: 0843 216 8833 Fax: 0843 216 4707 Website: www.fosterrefrigerator.co.uk Email: support@foster-uk.com a Division of „ITW (UK) Ltd‟ LCU15/LDU15 & ATI-5/SM 10/10 14
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 15 Language : en-US Tagged PDF : Yes Title : Author : kevin.nicholls Creator : Microsoft® Office Word 2007 Create Date : 2010:12:16 09:23:24 Modify Date : 2010:12:16 09:23:24 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools