E650 Series 3 (ZMD310AT/CT) Landis Technical Data
User Manual: Home
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
Electricity Meters IEC/MID Industrial+Commercial ZMD310AT/CT E650 Series 3 (ZMD310AT/CT) Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E650 series 3, the latest generation of ZxD300 meters. These meters feature a new hardware platform, combining modern technology with proven functions. Date: 06.04.2010 Filename: D000030104 E650 ZMD300xT series 3 Technical Data D000030104 d 2/6 The E650 directly connected I&C meters record active and reactive energy consumption in all threephase four-wire and three-phase three-wire networks. Range E650 meters are the answer to a wide range of specific needs: from the reliable commercial meter to the complex measuring device with comprehensive additional functionality for sophisticated data acquisition and flexible tariff control of large industrial customers. E650 Series 3 – ZMD310AT/CT Communication AT/CT-type meters are equipped with modular communication units which provide the right choice for the best data channel at all times. «Plug+Play» modules also offer you full freedom of choice for deployment of new communication technologies. Installation support The monitoring of voltage, current, demand and power factor supports the installation. Technical specifications MID-specific Data General Voltage Current (for class B) Nominal voltage Un Minimum current Imin 3 x 220/380 V to 240/415 V 3 x 110/190 V to 133/230 V Voltage range 80% to 115% Un Nominal frequency fn tolerance 50 or 60 Hz ± 2% 0.5, 1.0, 1.5, 2.0 A Maximum current Imax 120 A ZMD310AT/CT to EN 50470-3 class B Measurement Behaviour Starting current Ist IEC-specific Data 0.02, 0.04, 0.06, 0.08 A General Current selectable: 5, 10, 20 or 40 A Maximum current Imax metrological selectable: 40, 60, 80, 100 or 120 A thermal 120 A Short circuit ≤ 10 ms 5000 A Measurement Accuracy ZMD310xT active energy, to IEC 62053-21 reactive energy, to IEC 62053-23 class 1 accuracy 1% Starting current according to IEC 0.4% Ib typical 0.3% Ib The startup of the meter is controlled by the starting power and not by the starting current. Starting power in M-circuit nominal voltage x starting current Operating Behaviour Voltage failure (Power Down) bridging time data storage switch off 0.5 s after another 0.2 s after approx. 2.5 s Voltage restoration (Power Up) function standby 3 phases after 2 s function standby 1 phase after 5 s detection of energy direction and phase voltage after 2 to 3 s Power Consumption Measurement Behaviour © Landis+Gyr AG Transitional current Itr Measurement Accuracy Frequency Base current Ib 0.25, 0.5, 0.75, 1.0 A single phase Power consumption per phase in voltage circuit phase voltage 110 V 240 V active power (typical) 0.5 W 0.7 W apparent power (typical) 1.0 VA 1.7 VA Power consumption per phase in current circuit phase current 10 A apparent power (typical) 0.03 VA D000030104 d – E650 Series 3 (ZMD310AT/CT) – Technical Data 3/6 Display Environmental Influences Temperature range operation storage to IEC 62052-11 –25 °C to +70 °C –40 °C to +85 °C Temperature coefficient range –25 °C to +70 °C average value (typical) ± 0.012% per K at cosϕ=1 (from 0.05 Ib to Imax) ± 0.02% per K at cosϕ=0.5 (from 0.1 Ib to Imax) ± 0.03% per K Impermeability to IEC 60529 IP51 Electromagnetic Compatibility Electrostatic discharges contact discharge to IEC 61000-4-2 15 kV Electromagnetic RF fields 80 MHz to 2 GHz to IEC 61000-4-3 10 and 30 V/m Radio interference suppression according to IEC/CISPR 22 class B Fast transient burst test to IEC 61000-4-4 current and voltage circuits under load according to IEC 62053-21/23 4 kV auxiliary circuits > 40 V 2 kV Fast transient surge test current and voltage circuits auxiliary circuits > 40 V to IEC 61000-4-5 4 kV 1 kV Insulation Strength Insulation strength 4 kV at 50 Hz during 1 min. Impulse voltage 1.2/50 μs current and voltage circuits auxiliary circuits > 40 V to IEC 62052-11 8 kV 6 kV Protection class ll to IEC 62052-11 Calendar Clock Calendar Type Gregorian or Persian (Jalaali) Accuracy Backup time (power reserve) with supercap charging time for max. backup time with battery (optional) battery type < 5 ppm Characteristics type LCD liquid crystal display digit size in value field 8 mm number of digits in value field up to 8 digit size in index field 6 mm number of digits in index field up to 8 Inputs and Outputs Control inputs control voltage US input current 100 to 240 VAC < 2 mA ohmic at 230 VAC Output contacts type solid state relay voltage 12 to 240 VAC/DC max. current 100 mA max. switching frequency (pulse length 20 ms) 25 Hz Optical test outputs type number meter constant active and reactive energy red LED 2 selectable Communication Interface Optical interface to IEC 62056-21 type serial, bidirectional, half-duplex max. transmission rate 9600 bps protocols IEC 62056-21 and dlms Communication units Exchangeable communciation units for various applications Additional Power Supply (optional) On Extension Board 045x nominal voltage range tolerance frequency max. power consumption 100 to 240 VAC/DC 80 to 115% Un 50 or 60 Hz 6.8 W On Extension Board 046x nominal voltage range tolerance max. power consumption 12 to 24 VDC 80 to 115% Un 3.5 W > 20 days 300 h 10 years CR-P2 D000030104 d – E650 Series 3 (ZMD310AT/CT) – Technical Data © Landis+Gyr AG 4/6 Weight and Dimensions Connections Weight approx. 1.5 kg External dimensions width height (with short terminal cover) height (with standard terminal cover) height (with extended hook) depth Suspension triangle height (with extended hook) height (suspension eyelet open) height (suspension eyelet covered) width Terminal cover short standard long GSM ZxB-type 80 mm ZxB-type 110 mm ADP1 adapter RCR/FTY adapter © Landis+Gyr AG 177 mm 244 mm 281.5 mm 305.5 mm 75 mm 230 mm 206 mm 190 mm 150 mm no free space 40 mm free space 60 mm free space 60 mm free space 80 mm free space 110 mm free space Phase Connections type screw type terminals diameter for Imax ≤ 80 A 8.5 mm diameter for Imax > 80 A 9.5 mm minimal conductor cross section 4 mm2 2 max. cross section cable 35 mm (up to 120 A) max. cross section strand 25 mm2 (up to 80 A) screw head Pozidrive Combi No. 2 screw dimension M6 x 14 max. screw head diameter ≤ 6.6 mm tightening torque < 3 Nm Other Connections type screwless spring-type terminal max. current of voltage outputs 1A max. voltage of inputs 250 V Material Housing Polycarbonate, partly glass-fibre reinforced D000030104 d – E650 Series 3 (ZMD310AT/CT) – Technical Data 5/6 Meter Dimensions (standard terminal cover) extended hook: 230 190 40 26 standard hook: 206 75 150 177 Terminal Dimensions 9.5 15.3 Ø or .5 Ø8 19.75 19 14.5 14.5 14.5 14.5 14.5 14.5 16 13 16 16 13 13 12 13.5 Spacings of terminal openings Spacings of terminal stampings for smaller conductors Terminal Layout Inputs and/or output contacts of extension board U1 L1 U2 U3 L2 Pulse inputs Communication interfaces Communication unit Control inputs and output contacts Voltage outputs N L3 N Phase connections D000030104 d – E650 Series 3 (ZMD310AT/CT) – Technical Data © Landis+Gyr AG 6/6 ZMD 3 10 C T 44 4207 S3a Network Type ZMD 3-phase 4 wire network (M-circuit) Connection Type 3 Direct connection Accuracy Class 10 Active energy class 1 (IEC), B (MID) Measured Quantities C A Active and reactive energy Active energy Construction T With exchangeable communication units Tariffication 21 24 41 44 Energy rates, external rate control via control inputs Energy rates, internal rate control via time switch (additionally possible via control inputs) Energy and demand rates, external rate control via control inputs Energy and demand rates, internal rate control via time switch (additionally possible via control inputs) All versions with 3 control inputs and 2 output contacts Additional functions 060x 240x 420x 045x 046x 6 outputs 2 control inputs, 4 outputs 4 control inputs, 2 outputs 4 outputs, auxiliary power supply 100 to 240 VAC 4 outputs, auxiliary power supply 12 to 24 VDC xxx0 xxx2 xxx7 xxx9 no additional functions DC-magnet-detection load profile DC-magnet-detection and load profile Series 3 Copyright © 2009, Landis+Gyr. All rights reserved. Subject to change without notice. Landis+Gyr AG Feldstrasse 1 CH-6301 Zug Switzerland Phone: +41 41 935 6000 www.landisgyr.com © Landis+Gyr AG D000030104 d – E650 Series 3 (ZMD310AT/CT) – Technical Data
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Producer : Acrobat Distiller 8.2.0 (Windows) Company : Landis+Gyr AG Source Modified : D:20100407074332 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2010:04:07 09:44:30+02:00 Create Date : 2010:04:07 09:44:01+02:00 Metadata Date : 2010:04:07 09:44:30+02:00 Document ID : uuid:975c8cdc-8661-45f6-aaf1-760b6a32b6b8 Instance ID : uuid:aa5ef3ab-918e-4425-990a-aa251aad230b Subject : 106 Format : application/pdf Creator : Karl Spendel Title : E650 Series 3 (ZMD310AT/CT) Description : Technical Data Headline : Technical Data Page Count : 6 Page Layout : OneColumn Author : Karl SpendelEXIF Metadata provided by EXIF.tools