Keysight M9217A
PXIe Single-Slot 2-Channel Isolated Digitizer

Data Sheet

Introduction
The Keysight Technologies, Inc. M9217A is a PXI Express based, single-slot 2-channel, isolated
digitizer that supports up to ±256 V input voltage at 20 MSa/s sampling rate with 16-bit resolution.
With its built-in peak voltage protection of up to 400 V, the M9217A is ideal for analyzing high-voltage
and transient signals as seen in automotive, mechatronics and aerospace defense applications.

Key Features
–– ±256 V input voltage
–– 2-channel isolated, with ADCs per channel, simultaneously sampled channels
–– 20 MSa/s sampling rate at 16-bit resolution
–– Built-in 400 V peak voltage protection
–– Single PXI express slot
–– PXI trigger types supported: PXI TTL / trigger and PXI Star trigger
–– IVI-COM, IVI-C, LabVIEW G drivers

03 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

±256 V input voltage
Input channels with the ability to measure waveforms up to 256 V are ideal for analyzing
high-voltage and transient signals as seen in automotive and aerospace defense
applications. Most oscilloscopes and PXI digitizers have a maximum input range less
than 40 Vpk. This also reduces the need to add expensive input signal attenuation and
signal conditioning circuitry, saving test development time and money.

2-channel isolated, with ADCs per channel
In addition, since the ±256 V input voltage range is combined with 16-bit analog-todigital converters (ADCs), the isolated front-end and low input offset allows voltages
from as low as 250 mV to as high as 256 V to be measured simultaneously.
The M9217A’s individually isolated 2-channel inputs have been designed for high
performance with an A/D converter per channel to ensure the signals you measure
are accurately digitized without distortion or additional noise. Channel input range is
configurable from ±250 mV up to ±256 V, with a floating voltage up to ±40 V to accommodate differential waveform acquisition.

20 MSa/s sampling rate at 16-Bit resolution
The M9217A’s ability to support up to 20 MSa/s sampling rate at 16-bit resolution
enables sampling of transient waveforms like injector waveforms (Figure 1).

Vpk

toff

tpw
ton < 0.1 us
Vdson ~ 600 mV - 800 mV
toff ~ 10 us
Vpk ~ 70 V - 146 V
200 V (peak)

Ringing
ton
Vdson
Figure 1. Sample injector waveform

04 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

Built-in 400 V peak voltage protection
To support high voltage and transient signals in automotive, mechatronics and aerospace
and defense applications, the M9217A has a built-in peak voltage protection against
overvoltage spikes of up to 400 V.

32 MSa/channel with up to 1024 segmented memory
Coupled with the memory segmentation feature of up to 1024 records, the M9217A’s
32M sample memory size enables multiple bursts of data to be digitized without the
need for re-initialization between bursts. The record size is configured by selecting the
total number of samples, including pre-trigger samples.

Support for multiple trigger types		
The M9217A supports different trigger types like PXI trigger bus, PXI Star, external input/
output, channel and software trigger. Configurable trigger delay and trigger hold-off
allow you to better define where record data is collected relative to the trigger event.
The configurable trigger delay feature allows precise positioning of acquisition relative to
the trigger event, while the trigger hold-off feature helps avoid false triggers.
The PXI TTL trigger output enables the M9217A digitizer to synchronize to other devices.
Multiple M9217A digitizers can be synchronized for higher channel count.

IO Libraries
Keysight input/output or IO Libraries Suite offers fast and easy connection to instruments. The latest suite version extends that capability to include modular instruments.
New support for PXI such as the Keysight IO Libraries Suite helps you display all of
the modules in your system. From here, you can view information about the installed
software or start the soft front panel of the module. Launch the soft front panel of the
module directly from Keysight Connection Expert. Figure 2 shows the M9217A soft front
panel.

Figure 2. M9217A soft front panel

05 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

Drivers
The M9217A digitizer is supplied with a comprehensive portfolio of module drivers, documentation, examples, and software tools to help you quickly develop test systems with
your software platform of choice. The module comes with IVICOM, IVI-C, and LabVIEW
G software drivers that work in the most popular test and measurement development
environments, including LabVIEW and LabWindows/CVI from National Instruments,
Microsoft C/C++, C#, and VB.NET.

Easy software integration
The module software support provides context-sensitive help, complete documentation
and code examples that allow a quick module set up and basic acquisition functionalities.
These code examples can be easily modified, so that the card can be quickly integrated
into a test system. Included are application code examples for LabVIEW, LabWindows/
CVI, Visual Studio C, C++, and C# and Visual Basic.

Calibration Intervals		
The M9217A is factory-calibrated and shipped with a calibration certificate. Calibration is
recommended every year in order to verify product performance.

M9217A specifications
2-channel isolated digitizer with ADCs per channel and utilizing one PXI express slot.
Max sample rate

20 MSa/s

Sample resolution

16 bits

Input configuration

Isolated inputs ( each channel independently isolated)

Isolation voltage (low to chassis)

+40 V

Maximum input range (high to low)

+256 Vpk

Input impedance

1 MW // 40 pF

Input coupling

DC or AC

AC cutoff frequency

< 10 Hz

Input ranges

±256 V, ±128 V, ±64 V, ±32 V, ±16 V, ±8 V,
±4V, ±2 V, ±1 V, ±500 mV, ±250 mV

Over voltage protection

Yes

Maximum overvoltage protection

±400 Vppk

Analog bandwidth (-3 dB)

20 MHz typical

06 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

Trigger
Each trigger event causes acquisition of data into a single record at the configured sample rate. The
number of data records is configurable from 1 to 1024.
Source

Description

Immediate

Trigger at initiation of acquisition,

External

SMD connector, TTL input edge (rising edge)

PXI_Trig[0:7], PXI_STAR

PXI connector XJ4 , TTL input edge (rising edge)

DSTARB

PXIe connector XJ3, TTL input edge (rising edge)

Software

Instrument command

Channel/edge

Selectable level, rising/falling, hysteresis.

Channel/window

Selectable high and low levels, leaving/entering.

Sampling
Programmable sample rates

1 kSa/s, 2 kSa/s, 5 kSa/s, 10 kSa/s, 50 kSa/s, 100 kSa/s, 200 kSa/s,
500 kSa/s, 1 MSa/s, 2 MSa/s, 5 MSa/s, 10 MSa/s, 20 MSa/s

External event output

Trigger

Output signal

TTL ( rising edge )

Impedance

25 or 50 Ω

Pulse width

1 µs

Trigger modes
Record length

2 to 32 million samples

Pre trigger

0 to record length -1

Post trigger

Record length-pre-trigger

Timestamp triggered event

Continuous running timestamp

Timestamp resolution

10 ns

Trigger delay

0 – 3600 s with 50 ns resolution

Trigger hold-off

0 – 10 s with 50 ns resolution

Trigger latency

50 ns

1

1.

Latency between edge trigger detection and first trigger sample.

Accuracy
DC accuracy
Total specification (% of reading + % of range)
23 °C ±5%
Range

±% of reading

±% of range

250 mV

0.1

0.3

500 mV

0.1

0.2

1 V, 2 V

0.1

0.12

4 V, 64 V

0.1

0.3

8 V, 128 V

0.1

0.2

16 V, 32 V, 256 V

0.1

0.12

100,000 reading average @ 1 MSa/s
Integral nonlinearity

±5 LSB

Differential nonlinearity

±1 LSB

07 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

Dynamic characteristic (typical)

Noise power ( typical)

Source

Range

SFDR dBc

THD dBc

Noise voltage
Vrms

1

AC flatness (DC-4 MHz) typical
Equivalent
S/N dB

2

250 mV, 500 mV,
1 V, 2 V

< 0.3 dB relative to 20 kHz

250 mV

71

79

500 mV

77

83

250 mV

0.5 mV

51

4 V, 8 V, 16 V, 32 V

< 0.5 dB relative to 20 kHz

0.55 mV

55

128 V

< 1.2 dB relative to 20 kHz

1V

81

85

0.5 mV

2V

85

82

1V

0.6 mV

60

4V

70

80

2V

0.9 mV

63

4V

4 mV

56

8V

6.5 mV

58

16 V

8.5 mV

61

32 V

11 mV

65

Measured for input of 1 Mhz

64 V

60 mV

56

128 V

94 mV

58

256 V

120 mV

62

1. 50 Ω source resistance.
2. For -1 dB of full scale range

Waveform memory
Data memory standard1

32 Msa/ch

Random access to readings in multiple record mode Capture multiple records from single trigger
source
1.

Nominal values. Specific sample max is 30,000,000

Waveform measurements
Voltage

Peak-to-peak, Minimum, Maximum, High (Top), Low (Base), Amplitude, RMS,
Cycle RMS, Average, Cycle Average, Overshoot, Preshoot

Time

Rise, Fall, Frequency, Period, Positive Width, Negative Width, Positive Duty
Cycle, Negative Duty Cycle

Utilities
Calibration cycle

1 year

08 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet

Evolving Since 1939
Our unique combination of hardware, software, services, and people can help you
reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight.

myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.keysight.com/find/emt_product_registration
Register your products to get up-to-date product information and
find warranty information.
Keysight Services
www.keysight.com/find/service
Keysight Services can help from acquisition to renewal across your
instrument’s lifecycle. Our comprehensive service offerings—onestop calibration, repair, asset management, technology refresh,
consulting, training and more—helps you improve product quality
and lower costs.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure
your instruments are operating to specification, so you can rely on
accurate measurements.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and
product breadth, combined with channel partner convenience.

www.keysight.com/find/automotive

For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States

(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444

Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries

1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100

Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland

United Kingdom

0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637

For other unlisted countries:
www.keysight.com/find/contactus
(BP-9-7-17)

DEKRA Certified
ISO9001 Quality Management System

www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System

This information is subject to change without notice.
© Keysight Technologies, 2017
Published in USA, December 1, 2017
5992-0815EN
www.keysight.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36
Create Date                     : 2017:12:10 09:07:21-08:00
Metadata Date                   : 2017:12:10 09:07:26-08:00
Modify Date                     : 2017:12:10 09:07:26-08:00
Creator Tool                    : Adobe InDesign CC 13.0 (Macintosh)
Instance ID                     : uuid:0f82d37c-7af4-af42-8e44-7411abe6c919
Original Document ID            : xmp.did:5259B79ADEA3E311A5169BB3BD84A224
Document ID                     : xmp.id:17bb5dd9-fa62-4a1f-99ab-94c7fd769c93
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6217d32b-3b8f-4d77-94aa-c20587e1a7f4
Derived From Document ID        : xmp.did:E3E900F7F04FE5119D0ECCEABD99089F
Derived From Original Document ID: xmp.did:5259B79ADEA3E311A5169BB3BD84A224
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Macintosh)
History Changed                 : /
History When                    : 2017:12:10 09:07:21-08:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CC 13.0 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu