M9217A PXIe Isolated Digitizer 2_channels 16 Bit ±256 V 32 Msa_Ch Memory Data Sheet Brochure
User Manual: M9217A-PXIe-Isolated-Digitizer-2_channels-16-bit-±256-V-32-Msa_Ch-memory-Data-Sheet-Brochure
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Keysight M9217A PXIe Single-Slot 2-Channel Isolated Digitizer Data Sheet Introduction The Keysight Technologies, Inc. M9217A is a PXI Express based, single-slot 2-channel, isolated digitizer that supports up to ±256 V input voltage at 20 MSa/s sampling rate with 16-bit resolution. With its built-in peak voltage protection of up to 400 V, the M9217A is ideal for analyzing high-voltage and transient signals as seen in automotive, mechatronics and aerospace defense applications. Key Features –– ±256 V input voltage –– 2-channel isolated, with ADCs per channel, simultaneously sampled channels –– 20 MSa/s sampling rate at 16-bit resolution –– Built-in 400 V peak voltage protection –– Single PXI express slot –– PXI trigger types supported: PXI TTL / trigger and PXI Star trigger –– IVI-COM, IVI-C, LabVIEW G drivers 03 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet ±256 V input voltage Input channels with the ability to measure waveforms up to 256 V are ideal for analyzing high-voltage and transient signals as seen in automotive and aerospace defense applications. Most oscilloscopes and PXI digitizers have a maximum input range less than 40 Vpk. This also reduces the need to add expensive input signal attenuation and signal conditioning circuitry, saving test development time and money. 2-channel isolated, with ADCs per channel In addition, since the ±256 V input voltage range is combined with 16-bit analog-todigital converters (ADCs), the isolated front-end and low input offset allows voltages from as low as 250 mV to as high as 256 V to be measured simultaneously. The M9217A’s individually isolated 2-channel inputs have been designed for high performance with an A/D converter per channel to ensure the signals you measure are accurately digitized without distortion or additional noise. Channel input range is configurable from ±250 mV up to ±256 V, with a floating voltage up to ±40 V to accommodate differential waveform acquisition. 20 MSa/s sampling rate at 16-Bit resolution The M9217A’s ability to support up to 20 MSa/s sampling rate at 16-bit resolution enables sampling of transient waveforms like injector waveforms (Figure 1). Vpk toff tpw ton < 0.1 us Vdson ~ 600 mV - 800 mV toff ~ 10 us Vpk ~ 70 V - 146 V 200 V (peak) Ringing ton Vdson Figure 1. Sample injector waveform 04 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet Built-in 400 V peak voltage protection To support high voltage and transient signals in automotive, mechatronics and aerospace and defense applications, the M9217A has a built-in peak voltage protection against overvoltage spikes of up to 400 V. 32 MSa/channel with up to 1024 segmented memory Coupled with the memory segmentation feature of up to 1024 records, the M9217A’s 32M sample memory size enables multiple bursts of data to be digitized without the need for re-initialization between bursts. The record size is configured by selecting the total number of samples, including pre-trigger samples. Support for multiple trigger types The M9217A supports different trigger types like PXI trigger bus, PXI Star, external input/ output, channel and software trigger. Configurable trigger delay and trigger hold-off allow you to better define where record data is collected relative to the trigger event. The configurable trigger delay feature allows precise positioning of acquisition relative to the trigger event, while the trigger hold-off feature helps avoid false triggers. The PXI TTL trigger output enables the M9217A digitizer to synchronize to other devices. Multiple M9217A digitizers can be synchronized for higher channel count. IO Libraries Keysight input/output or IO Libraries Suite offers fast and easy connection to instruments. The latest suite version extends that capability to include modular instruments. New support for PXI such as the Keysight IO Libraries Suite helps you display all of the modules in your system. From here, you can view information about the installed software or start the soft front panel of the module. Launch the soft front panel of the module directly from Keysight Connection Expert. Figure 2 shows the M9217A soft front panel. Figure 2. M9217A soft front panel 05 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet Drivers The M9217A digitizer is supplied with a comprehensive portfolio of module drivers, documentation, examples, and software tools to help you quickly develop test systems with your software platform of choice. The module comes with IVICOM, IVI-C, and LabVIEW G software drivers that work in the most popular test and measurement development environments, including LabVIEW and LabWindows/CVI from National Instruments, Microsoft C/C++, C#, and VB.NET. Easy software integration The module software support provides context-sensitive help, complete documentation and code examples that allow a quick module set up and basic acquisition functionalities. These code examples can be easily modified, so that the card can be quickly integrated into a test system. Included are application code examples for LabVIEW, LabWindows/ CVI, Visual Studio C, C++, and C# and Visual Basic. Calibration Intervals The M9217A is factory-calibrated and shipped with a calibration certificate. Calibration is recommended every year in order to verify product performance. M9217A specifications 2-channel isolated digitizer with ADCs per channel and utilizing one PXI express slot. Max sample rate 20 MSa/s Sample resolution 16 bits Input configuration Isolated inputs ( each channel independently isolated) Isolation voltage (low to chassis) +40 V Maximum input range (high to low) +256 Vpk Input impedance 1 MW // 40 pF Input coupling DC or AC AC cutoff frequency < 10 Hz Input ranges ±256 V, ±128 V, ±64 V, ±32 V, ±16 V, ±8 V, ±4V, ±2 V, ±1 V, ±500 mV, ±250 mV Over voltage protection Yes Maximum overvoltage protection ±400 Vppk Analog bandwidth (-3 dB) 20 MHz typical 06 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet Trigger Each trigger event causes acquisition of data into a single record at the configured sample rate. The number of data records is configurable from 1 to 1024. Source Description Immediate Trigger at initiation of acquisition, External SMD connector, TTL input edge (rising edge) PXI_Trig[0:7], PXI_STAR PXI connector XJ4 , TTL input edge (rising edge) DSTARB PXIe connector XJ3, TTL input edge (rising edge) Software Instrument command Channel/edge Selectable level, rising/falling, hysteresis. Channel/window Selectable high and low levels, leaving/entering. Sampling Programmable sample rates 1 kSa/s, 2 kSa/s, 5 kSa/s, 10 kSa/s, 50 kSa/s, 100 kSa/s, 200 kSa/s, 500 kSa/s, 1 MSa/s, 2 MSa/s, 5 MSa/s, 10 MSa/s, 20 MSa/s External event output Trigger Output signal TTL ( rising edge ) Impedance 25 or 50 Ω Pulse width 1 µs Trigger modes Record length 2 to 32 million samples Pre trigger 0 to record length -1 Post trigger Record length-pre-trigger Timestamp triggered event Continuous running timestamp Timestamp resolution 10 ns Trigger delay 0 – 3600 s with 50 ns resolution Trigger hold-off 0 – 10 s with 50 ns resolution Trigger latency 50 ns 1 1. Latency between edge trigger detection and first trigger sample. Accuracy DC accuracy Total specification (% of reading + % of range) 23 °C ±5% Range ±% of reading ±% of range 250 mV 0.1 0.3 500 mV 0.1 0.2 1 V, 2 V 0.1 0.12 4 V, 64 V 0.1 0.3 8 V, 128 V 0.1 0.2 16 V, 32 V, 256 V 0.1 0.12 100,000 reading average @ 1 MSa/s Integral nonlinearity ±5 LSB Differential nonlinearity ±1 LSB 07 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet Dynamic characteristic (typical) Noise power ( typical) Source Range SFDR dBc THD dBc Noise voltage Vrms 1 AC flatness (DC-4 MHz) typical Equivalent S/N dB 2 250 mV, 500 mV, 1 V, 2 V < 0.3 dB relative to 20 kHz 250 mV 71 79 500 mV 77 83 250 mV 0.5 mV 51 4 V, 8 V, 16 V, 32 V < 0.5 dB relative to 20 kHz 0.55 mV 55 128 V < 1.2 dB relative to 20 kHz 1V 81 85 0.5 mV 2V 85 82 1V 0.6 mV 60 4V 70 80 2V 0.9 mV 63 4V 4 mV 56 8V 6.5 mV 58 16 V 8.5 mV 61 32 V 11 mV 65 Measured for input of 1 Mhz 64 V 60 mV 56 128 V 94 mV 58 256 V 120 mV 62 1. 50 Ω source resistance. 2. For -1 dB of full scale range Waveform memory Data memory standard1 32 Msa/ch Random access to readings in multiple record mode Capture multiple records from single trigger source 1. Nominal values. Specific sample max is 30,000,000 Waveform measurements Voltage Peak-to-peak, Minimum, Maximum, High (Top), Low (Base), Amplitude, RMS, Cycle RMS, Average, Cycle Average, Overshoot, Preshoot Time Rise, Fall, Frequency, Period, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle Utilities Calibration cycle 1 year 08 | Keysight | M9217A PXIe Single-Slot 2-Channel Isolated Digitizer - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—onestop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/automotive For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, December 1, 2017 5992-0815EN www.keysight.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36 Create Date : 2017:12:10 09:07:21-08:00 Metadata Date : 2017:12:10 09:07:26-08:00 Modify Date : 2017:12:10 09:07:26-08:00 Creator Tool : Adobe InDesign CC 13.0 (Macintosh) Instance ID : uuid:0f82d37c-7af4-af42-8e44-7411abe6c919 Original Document ID : xmp.did:5259B79ADEA3E311A5169BB3BD84A224 Document ID : xmp.id:17bb5dd9-fa62-4a1f-99ab-94c7fd769c93 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:6217d32b-3b8f-4d77-94aa-c20587e1a7f4 Derived From Document ID : xmp.did:E3E900F7F04FE5119D0ECCEABD99089F Derived From Original Document ID: xmp.did:5259B79ADEA3E311A5169BB3BD84A224 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.0 (Macintosh) History Changed : / History When : 2017:12:10 09:07:21-08:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CC 13.0 (Macintosh)EXIF Metadata provided by EXIF.tools