MDV24 MFV24 Opman

User Manual: MDV24

Open the PDF directly: View PDF PDF.
Page Count: 16

DownloadMDV24 MFV24 Opman
Open PDF In BrowserView PDF
Operation Manual, Parts Directory and Price List

MFV24
Reach-In Mug Chillers

MFV24-SS(L)
with optional casters

This manual applies to MFV24 models manufactured prior to SN404144876N and
July 10, 2013. For MFV24 models manufactured after, please see the Front Venting
Self-Contained Coolers and Mug Frosters manual.
Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com
Rev 02-13-18

© 2010 Glastender, Inc.

Index
Installation
Introduction............................................................................... 1
Utility requirements and connections....................................... 1
Uncrating and start-up instructions........................................... 1
Operation................................................................................... 1
Cleaning instructions................................................................ 2
Floor sealing instructions.......................................................... 2
Electrical and refrigeration specifications................................ 2
Service and Parts
Terms and Conditions............................................................... 3
Warranty statement................................................................. 12
Wiring Diagram........................................................................... 4
Parts and Service
Compressor and condenser related parts...............................5-6
Evaporator and related parts..................................................... 7
Electrical components............................................................... 8
Shelving and related parts......................................................... 9
Doors, tops and related parts.................................................. 10
Refrigeration compartment covers......................................... 11

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Installation
Introduction
This manual describes the operational features of the Reach-In Mug Chiller model MFV24. Please review this information
before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for
selecting Glastender, Inc. products.

Utility Requirements and Connections
• Electrical:

115 Volt AC, 1 Phase, 60 Hz, 8.55 Full Load Amps. A separate 15 Amp circuit is recommended. A 6-foot
grounded cord is included.

• Plumbing:

Automatic condensate evaporator is included. No drain connection required.

Uncrating and Start-Up Instructions
All Reach-In Mug Chiller models are shipped in one carton. These steps should be followed:
1.
2.
3.
4.
5.
6.
7.

If legs or casters are included, bolt them to the base with the bolts provided.
Unwrap power cord from base.
Position the Reach-In Mug Chiller and level and/or seal as required (see page 2).
Install shelves.
Plug into 115 volt AC outlet.
Load with mugs, glasses, plates, etc.
Your Glastender Reach-In Mug Chiller is now ready for use.

Operation
The Reach-In Mug Chiller is designed to chill mugs, glasses, plates, etc. that will appear “frosted” when removed. The operating
temperature range of 0°F(-18°C) to 35°F(2°C).
The Reach-In Mug Chiller should be filled with dry, room-temperature mugs, glasses, plates, etc. to allow maximum chilling.
During business hours, the Reach-In Mug Chiller can be loaded with additional dry, room-temperature mugs, glasses, plates,
etc. Allow 30 minutes for chilling.
The Reach-In Mug Chiller includes an automatic defrost system. Defrosting will occur every six hours for approximately 20
minutes. During the defrost cycle, the fan inside the Reach-In Mug Chiller will turn off and a small amount of mist may appear
if the door is opened.
There is also a manual defrost system controlled by a switch located on the front left bottom of the Reach-In Mug Chiller. This
is used when there is ice or snow accumulation inside. An end-of-the-day or weekly schedule can be established for the activation of this manual defrost cycle.
When the manual defrost switch is pushed, a light will turn on and the Reach-In Mug Chiller will go into a six-hour defrost.
After six hours, the Reach-In Mug Chiller will resume normal operation.
If the manual defrost switch is accidentally pushed, the defrost cycle can be terminated by unplugging the power cord for
three seconds.

1

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Installation
Cleaning Instructions
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,
since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if
not removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto
the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature failure, since alcohol and moisture build-up breaks down the gasket material.

Sealing Reach-In Mug Chiller Base to Floor
To comply with NSF & health codes. The Reach-In Mug Chiller base must be sealed to the floor using NSF listed sealant.
Place a bead of sealant along outer edges of the base and remove excess with disposable towel.

Electrical and Refrigeration Specifications
Model
(L-to-R length)
24”

Electrical
115V, 1Ph., 60 Hz., 8.55 Amp

Refrigerant
Type Charge
R404A

9.75oz.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Design
Pressure
High Low
350

175
2

Terms and Conditions
Prices:
All prices are LIST. Applicable taxes will be added.
Quotations:
Unless otherwise stated, quotations are effective for 30 days only.
Acceptance:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in
Saginaw, Michigan. Possession of the Product Directory and Price List
is not an offer to sell.
Shipments:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or
Collect if shipped directly to you. Prepay and Add to Invoice freight
terms are available upon request. The approximate shipping weights of
all products are listed with the prices. Partial shipments will be made
unless otherwise specified by the customer. Surface freight classifications are:
• GT-24/GT-30/GW24 Glasswashers - Class 175
• GT-18 Glasswashers - Class 250
• All Underbar Equipment - Class 175
• Bar Die Orders – Class 250
• Portable Bars - Class 175
• Remote refrigerators (i.e., no compressor) or dry storage back bar
equipment - Class 175
• Self-contained refrigeration equipment - Class 150
• Ice Display Units (IDU and GDU) - Class 85
• Lighted Liquor Displays - Class 85
• Beer line chillers and beer towers (beverage dispensing equipment)
- Class 92.5
• Bottle Disintegration System - Class 150
• Ice Cream Freezers - Class 77.5
All small items are evaluated to see the most cost effective means for
shipment. Many small items ship via UPS or FedEx; however, when
dimensional weight is excessive, LTL carriers are the most cost effective
choice. Spare parts orders received before 1:00 PM EST can usually be
shipped the same day.
The order department is happy to assist with routing or shipping questions.

Delivery:
The majority of equipment is manufactured to order and typically ships
within three to six weeks after complete order information is received by
the factory. In-stock equipment typically ships within two to three days
of the factory receiving complete order information.
Returns:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Authorization number must be issued by the factory in
advance for any items that are returnable. The number MUST be noted
on the outside of the returned package. Returns must be received within
90 days of the issue date. Shipping charges must be prepaid. A minimum 20% restocking charge will be applied to all authorized returns if
received in new, unused condition in the original packaging.
The above conditions apply to spare part returns, except spare part
returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts.
Loss or Damage:
For customer routed shipments, Glastender, Inc. is not responsible for
any loss, damage, or delay of merchandise during shipment. Such transit
claims must be filed with the carrier. Merchandise must be examined on
arrival. If shortages occur, Glastender, Inc. must be notified in writing
within five (5) days of delivery to honor any shortage claim. Glastender
will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon
receipt. Failure to do so may result in losses at the customer’s expense.
Custom Orders:
Custom orders must be paid in advance and are not subject to cancellation.
Laminates:
Some products include common, readily available plastic laminates of
the customer’s selection. There may be an additional charge if uncommon varieties are ordered.
12/14/17

Payment Terms:
Cash should be included with all orders unless credit terms have been
arranged. To establish credit, banking and trade references are required.
A convenient credit application is available upon request. Payment via
credit card is not our normal means of receiving payment. Visa and
MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than
$500 will incur a 3% convenience fee on the total transaction amount.

3

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Wiring Diagram
W

W

1
P

P

5

W

2

7

W

2

OPTIONAL
GLASS DOOR
HEATER
FOR MFV-24

3
BL

A

W

B

5

4
O

W

O

W
P

NEUTRAL

4

GROUND
POWER

1

8
2
M

B

6

9

W

OPENS ABOVE +45°F

W

7

W/R

B

BR

3

B

115 VOLT
15 AMP. SERVICE
RECOMMENDED

R

11
P

10

5

W

1
P

4

P
2

3

W

LEGEND

B

W
12

B = Black
BL = Blue
BR = Brown
O = Orange
R = Red
P = Purple
W = White
W/R = White W/ Red

14
5
1

S

C

M

2
M
13

ELECTRICAL RATINGS

6

115V, Single Phase, 60Hz, 3 wire.
All wires are 16 Gauge

15

3
7.60 AMP
Compressor
Condensing Unit Fan Motor .82 AMP
Evaporator Fan Motor
.53 AMP
TOTAL AMPS
8.85

16
COMPRESSOR WIRING

ITEM

1/26/95

GT#

MT#

RELAY, EVAPORATOR FAN, 115v, MUG FROSTER

GT-034907
GT-034105

07000171
07000166

MOTOR, EVAPORATOR FAN, 115v

GT-035107

06001445
07000621

GT-035026
GT-035114

07000175
06001449

GT-033000
GT-033413

06001397
07000165

GT-034704
GT-033401

07000169
07000257

GT-033001
GT-031207

07000156
07000128

GT-034112
GT-032206

07000168
06001380

1

DESCRIPTION
LIGHT, MANUAL DEFROST, RED, 125v

2
3
4

THERMOSTAT

5

COMPRESSOR, 1/3 hp, R404a, (TECUMSEH) AFTER 01/2002

6

CONDENSER, FAN MOTOR, 6W

7

DEFROST TIMER, AUTOMATIC, 115v 6-HOUR, PARAGON

8

SENSOR, DEFROST

9

DEFROST HEATER, 115v

10

SWITCH, MANUAL DEFROST, START AND CYCLE TEST

11

MANUAL DEFROST TIMER, 6 HOUR

12

OVERLOAD PROTECTOR, 1/3hp R404a, TECUMSEH

13

RELAY, 1/3hp R404a, TECUMSEH COMPRESSOR

14
15

START CAPACITOR, 1/3hp R404a, TECUMSEH COMPRESSOR
FAN BLADE, CONDENSER, 5 BLADE

16

EVAPORATOR FAN BLADE, 5 BLADE, BLACK

GT-032803

07000155

GT-032804

09000298

Mug Froster
MFV Wiring

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

4

Compressor and Condenser Related Parts
9

13

1

16
15

14
17
18

2

20
10
19

12
23
2

21

22
5

4

3

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

11

Compressor and Condenser Related Parts
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.

Part No.

Old Part No.

Description

07000173
07000151
06001414
07000127
07000175
06001380
07000168
07000128
06001449
07000155
06001321
07000179
07000152
06001445
09000298
07000133
07000953
08000078
08000125
07000235
06001345
06001385
06001313

GT-035008
GT-032203
GT-034103
GT-031205
GT-035026
GT-032206
GT-034112
GT-031207
GT-035114
GT-032803
GT-031515
GT-035714
GT-032302
GT-035107
GT-032804

1/3 HP Aspera compressor, R404A (prior to 01/00)
$450.00
Start Capacitor, Aspera 1/3 HP R404A compressor
25.00
Relay for 1/3 HP Aspera, R404A compressor
14.00
Overload protector, Aspera 1/3 HP R404A compressor
15.00
1/3 HP Tecumseh compressor, R404A (after 01/00)
375.00
Start Capacitor, for Tecumseh 1/3 HP R404A compressor
40.00
Relay for Tecumseh 1/3 HP R404A compressor
32.25
Overload protector, for Tecumseh 1/3 HP R404A compressor
12.00
Motor, condenser fan, 6W
100.00
Fan blade, condenser, 5 blade (metal)
12.00
Bracket, condenser fan motor mounting (metal)
5.00
Nut, condenser fan blade mounting
1.00
Fan shroud, condenser
15.00
Motor, circulation fan
45.00
Fan blade, circulation fan, five blade (black plastic)
5.00
Bracket, circulation fan motor
20.00
Accumulator, suction line
30.00
Condenser coil
145.00
Pan, condensate
60.00
Wicking material, 4", consists of 11 pieces
14.00
Tubing, drain, clear plastic, 1/2" ID x 5/8" OD, per foot
1.45
Filter dryer, 1/4" x 1/4"
20.00
Condensing unit power cord
20.00

GT-032607
GT-038006
GT-038203
GT-031716
GT-031400

Price

6
5

8

7

Tecumseh 1/3 HP Compressor

Tecumseh 1/3 HP Compressor

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

6

Evaporator and Related Parts
Part No.

07000380
07000504
06001445
07000310
09000298
07000153
07000362
07000134
07000621
07000165
07000169
07000228
07000365
12. 07000141
13. 07000182
07000364
07000183
07000360
07000724
14. 06001574
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.

12

Old Part No.

GT-035107
GT-031514
GT-032804
GT-032303
GT-031516
GT-033413
GT-034704
GT-037420
GT-031549
GT-036100
GT-036101

GT-038833

Description

Evaporator coil replacement kit, prior to SN 404105086N
$180.00
Evaporator coil SN 404105068N and after
160.00
Fan motor, evaporator
45.00
Bracket, evaporator fan motor
14.00
Fan blade, evaporator, 5 blade (black plastic)
5.00
24.00
Evaporator fan box back, prior to SN 404105086N
24.00
Evaporator fan box back, SN 404105086N and after
Temperature control mounting bracket, prior to SN 404105086N
10.00
Thermostat, includes knob, plate, and tubing
70.00
Defrost sensor
35.00
Defrost heater
60.00
Evaporator housing, prior to SN 404105086N
60.00
Evaporator housing, SN 404105086N and after
60.00
Evaporator mounting bracket
12.00
Cover, front, evaporator, prior to SN 404105086N
54.00
Cover, front, evaporator, SN 404105086N and after
54.00
Cover, bottom, evaporator, prior to SN 404105086N
42.00
Cover, bottom, evaporator, SN 404105086N and after
42.00
Tubing, capillary, .049x64"
20.00
10-32" x 1/2" thumbscrew (4 required) (2 req prior to SN 404105086N) 2.00

Unit prior to
SN 404105086N

14

8

Price

SN 404105068N
and after

11

5

4
3

13

2
7
6

10

1

9
7

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Electrical Components
Part No.

Old Part No.

Description

Price

$35.00
40.00

GT-031608
GT-033000
GT-033001
GT-033301
GT-033302
GT-033304
GT-033401
GT-034105
GT-034907

Power cord, exterior, 132" long
Replacement power cord assembly,
includes (06001572, 01000669, 06009527)
Decal, control module
Automatic defrost
Manual defrost timer (6 hr)
Receptacle, 3 wire, mate-n-lok
Receptacle, 6 wire, mate-n-lok
Receptacle, compressor
Manual defrost switch
Evaporator fan relay
Manual defrost light, red

1. 06009527
07000599
2.
3.
4.
5.
6.
7.
8.
9.
10.

07000246
06001397
07000156
01000547
06001634
06001409
07000257
07000166
07000171

7.00
32.00
90.00
1.00
1.50
5.00
20.00
65.00
10.00

9

3

3

9

2

5

8

6

4

10
7

4
1
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

8

220 Volt Electrical Parts
Part No.

07000281
06001793
06001794
06001795
06001451
06001448
07000170
06001398
07000157
14000086
07000167

Description

Price

Compressor, 1/3 HP, 220/50Hz, R404A
Start capacitor, for 1/3 HP R404A and R22 compressor, 220/50Hz
Relay, compressor, 1/3 HP, 220V/50Hz, R404A
Overload for 1/3 HP R404A compressor, 220/50Hz
Motor, condenser fan, 9 watt, 220V 50/60 Hz
Motor, evaporator fan, 220V
Defrost heater, 220V
Defrost timer, automatic, 220V, 50 cycle
Defrost timer, manual, 220V, 50 cycle, 6 hour
Light, red, 220V
Relay, evaporator fan, 220V

$750.00
25.00
10.00
15.00
120.00
57.00
115.00
43.00
140.00
12.00
72.50

Shelving and Related Parts
1.
2.
3.
4.
5.

Part No.

Old Part No.

Description

Price

07000139
07000140
07000159
07000160
07000226
06001574

GT-031547
GT-031548
GT-033104
GT-033105
GT-036943
GT-038833

8" shelf bracket (2 required)
14" shelf bracket (2 required)
Shelf, 19-5/8" x 19-5/8", bottom & middle (2 required)
Shelf, 9-13/16" x 19-5/8", top (1 required)
Shelf kit (07000159 = 2, 07000160 = 1)
10-32" x 1/2" thumbscrew, ss

1

$10.00
16.00
50.00
35.00
135.00
2.00

4

3

2

5

MFV24 = 2

Entire Shelving kits for: MFV24 = 07000226

9

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

MFV24 = 1

Doors, Tops, and Related Parts
Part No.

1. 06001462
06001653
07000218
2. 07000219
07000220
07000221
07000963

Old Part No. Description

Price

GT-035402
GT-035401
GT-036260
GT-036261
GT-036262
GT-036263
07000372/3*

Door handle, mirror finish stainless steel
Door handle, polished brass
Door, black vinyl-clad
Door, stainless steel
Door, unlaminated
Door, laminated
Door, glass, black, triple pane (* replaces 07000372 and
07000373, heated glass doors)
07000964 07000374/5* Door, glass, stainless, triple pane (* replaces 07000374 and
07000375, heated glass doors)
07000966 07000376 * Door, glass, laminate, triple pane, right (* Heated door, discontinued)
07000965 07000377 * Door, glass, laminate, triple pane, left (* Heated door, discontinued)
3. 06001710 GT-038121 Top, stainless steel
07000265 GT-038122 Top, laminated
06001536 GT-036602 Door lock, stainless
06004009
Key, #806, for stainless cooler door lock (06001536)
06001535 GT-036601 Door lock, brass
06004010
Key, #606, for brass cooler door lock (06001535)
4. 07000356
Lock bracket
5. 06001363 GT-032105 Hinge set and brackets, right (complete with screws)
06001364 GT-032106 Hinge set and brackets, left (complete with screws)
07000267 GT-032109 Lock bracket for wood door
06001365 GT-032107 Hinge set and brackets, for wood door, right (complete with screws)
07000268 GT-032108 Hinge set and brackets, for wood door, left (complete with screws)
6. 06001569 GT-038495 Bushing, cooler door hinge, (black)
7. 06001485 GT-036012 Washer, nylon, cooler door hinge
8. 07000131* GT-031325 Gasket, door, MFV24, black, 23½" x 24" OD (*Heated glass door)
06003713
Gasket, door, 22-1/2" x 23" OD, triple pane glass door, after 03/2017

$60.00
110.00
308.00
408.00
308.00
440.00
688.00

738.00
808.00
808.00
240.00
385.00
36.00
4.00
43.00
4.00
5.00
35.00
35.00
5.00
40.00
40.00
1.00
1.00
42.00
42.00

3

4

1

6

7

2

5
8
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

10

Refrigeration Compartment Covers
Part No.

07000204
1. 07000205
2. 07000206
07000207
3. 07000784
07000785
4. 07000786
07000783

Old Part No.

Description

Price

GT-036163
GT-036165
GT-036166
GT-036167

Front, black vinyl-clad
Front, stainless steel
Back, black vinyl-clad
Back, stainless steel
Side, left, stainless steel
Side, left, black vinyl-clad
Side, right, stainless steel
Side, right, black vinyl-clad

$33.00
48.00
40.00
80.00
80.00
40.00
80.00
40.00

Front view

Front view

3

1

Rear view

2

11

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

4

Warranty Statement
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
Glastender, Inc. warrants all products to be free of defects in material and workmanship. One-year labor and parts warranty applies to
all glasswashers, self-contained refrigeration models, and BDS model
bottle disintegration units. In established areas, a start up is included
with GT-24 and GT-30 model glasswashers. Warranty is effective for
one year from the date of installation or up to 18 months from date of
factory shipment, whichever occurs sooner. Glastender, Inc. will replace
any part or assembly found defective under normal use and service.

SECOND YEAR EXTENDED PARTS & LABOR WARRANTY:

For warranty labor claims beyond 15 months from the date of factory
shipment, proof of date of installation or occupancy must be provided.
Authorization for labor must be obtained from Glastender within the
warranty period and prior to the service being performed.

EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE
OR NON-INFRINGEMENT.

Labor warranty applies to the United States and Canada only.
Remote refrigeration models and beer line chillers include a one-year
parts warranty only. There is no labor warranty on these products.
Field replacement parts not covered under the original warranty include
a 90-day part warranty from the date of installation.
FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY:
Glastender will warrant to the original user the compressor for all selfcontained refrigeration models for an additional four years following the
regular one-year warranty period. This plan applies to the compressor
only.
A completed warranty claim form MUST accompany all returned defective parts or assemblies. Upon request, a defective part or assembly must
be returned to Glastender, Inc., Saginaw, Michigan, with all transportation and delivery charges prepaid. Warranty repairs or replacements
will be shipped FOB factory in Saginaw, Michigan. Reimbursement for
applicable freight charges covers ground service only.
Glastender provides in-warranty repairs during a service company’s
regular working days and hours. There is no provision for payment
of a premium rate during “overtime” hours. When warranty service is
requested during other than normal working hours, the end user will be
charged the premium portion of the overtime rate.
The warranty covers substantiated travel expenses for up to 2 hours /
100 miles round trip up to a maximum of $150. Any additional costs
due to installations that require extra work, time, or travel to gain access
for service are the sole responsibility of the equipment purchaser. Any
exceptions to these travel and access limitations must be pre-approved
by a factory representative.
The warranty does not cover door gaskets, chemical tubing, pump
squeeze tubing, and/or any equipment subjected to accidents, freight
damage, alterations from the original design, improper power and/or
plumbing hookups, improper chemical use, general misuse, or lack
of routine required maintenance as determined by Glastender, Inc.
Installation, normal control adjustments, general maintenance, correcting an installation error, or service calls that reveal the unit is functioning normally will not be reimbursed under warranty.
Condenser coils on self-contained refrigeration products must be
cleaned regularly. Failure to provide adequate air flow to a refrigeration
unit will void the warranty.
Glastender shall not be liable for loss of use, revenue, or profit, or for
any other indirect, incidental, special, or consequential damage including, but not limited to, product spoilage or loss.
This warranty is conditioned upon Glastender receiving notice of any
defect subject to this warranty within sixty (60) days of its discovery
by the end user or dealer. All products are warranted only for the initial
place of installation. Removal of a product automatically terminates
this warranty.

Glastender’s one-year parts and labor warranty on self-contained refrigeration units, excluding beer line chillers, can be extended to two years
with the purchase of a two year parts and labor warranty. Specify part
number EWR2 ($150 net price) when ordering.
EXPORT WARRANTY - One year parts only.
EXCLUSION OF WARRANTIES

LIMITATION
OF
REMEDIES
AND
DAMAGES
If Buyer makes a valid and timely claim as outlined above, Glastender’s
liability and Buyer’s remedies under this agreement will be limited solely
to labor charges authorized and/or replacement or credit, at Glastender’s
option, with respect to Products returned at Buyer’s expense within thirty (30) days after warranty repair. GLASTENDER’S LIABILITY WILL
IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE
PRICE OF THE RETURNED PRODUCTS. GLASTENDER
WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING,
BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED
UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF
PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR
INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS’
INCORPORATION INTO OR BECOMING A COMPONENT OF
ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY
NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR
TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS
AGREEMENT.
GOVERNING LAW - JURISDICTION
The terms and conditions of an order are to be governed and construed
according to the laws of the State of Michigan, without regard to conflict
of laws principles. Buyer hereby consents to the jurisdiction and venue
of the courts located in Saginaw County, Michigan.
No representative, distributor, dealer, or any other person is authorized
to modify this warranty. This warranty replaces all other written or
verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement
means that prices, specifications, and policies are subject to change
without notice. Questions regarding this warranty should be directed to
Glastender’s Warranty Administrator.
04-19-17

IMPORTANT!!
Attention Service Companies
Please review the important warranty information on this page. If you
believe a service call should be covered by the factory, please call
the factory for authorization between 8AM and 5PM EST, Monday
through Friday.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

12

UNPARA LLELED UNDERBAR DESIGN & ENGINEERING

Expect more

more flexibility

more features

Glastender has the most complete line of bar equipment and
the ability to manufacture custom units, giving you virtually
unlimited design flexibility. Each piece of equipment is
engineered with features that enhance your efficiency, ease
your maintenance, and prolong the life of your investment.
The flexibility you want. The features you need.
Glastender. Expect more.

GLASSWASHERS • COCKTAIL STAT IONS • CO OLERS • FROST ERS • BEER SYST EMS



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2018:02:13 09:10:49-05:00
Modify Date                     : 2018:02:13 09:10:52-05:00
Metadata Date                   : 2018:02:13 09:10:52-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Version ID                      : 1
Instance ID                     : uuid:c0fba292-d4dd-4070-9dbf-a88babee6e44
Original Document ID            : adobe:docid:indd:cbc45535-f149-11dd-8774-e962fe4e45a8
Document ID                     : xmp.id:D5CBA0A5C710E811BC28D2A6B784F58D
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:D4CBA0A5C710E811BC28D2A6B784F58D
Derived From Document ID        : xmp.did:F2EA4FE42BB4E31191F2ED943286B989
Derived From Original Document ID: adobe:docid:indd:cbc45535-f149-11dd-8774-e962fe4e45a8
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2018:02:13 09:10:49-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 16
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu