Technical Specifications APC Modular Power Distribution Unit APC 144kVA Modular Power Distribution Unit, Isolation Transformer, 480:208V, 72 Poles, 2 Subfeed APC 144kVA Modular Power Distribution Unit, Isolation Transformer, 600:208V, 72 Poles, 2 Subfeed APC 175kVA Modular Power Distribution Unit, Isolation Transformer, 480:415V, 72 Poles, 2 Subfeed Table of Contents Technical Data............................................................................................ 1 Modular PDU Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Power Distribution Modules Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Communication and Management ........................................................... 2 Display Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Menu tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 List Of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Network Management Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Input and Output Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Facility Planning ........................................................................................ 5 Input Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mains Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mains Input Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Maximum Short-Circuit Withstand Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Output Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Recommended Conductor Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 40° Ambient / 3CCC, 150 & 175 kW Modular PDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 30° Ambient / 3CCC, 150 & 175 kW Modular PDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 CB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 JLF361150C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Transformer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Drawings................................................................................................... 12 Options ..................................................................................................... 16 Hardware Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Power Distribution Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APC Power Distribution Modules for 208V Modular PDUs . . . . . . . . . . . . . . . . . . . . Power Distribution Modules continued . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APC Power Distribution Modules for 415V Modular PDUs . . . . . . . . . . . . . . . . . . . . Seismic Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bottom Feed Side Cars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 16 17 17 18 18 Shunt Trip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Configuration Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 990-4806 150/175 kVA Modular PDU Technical Specification i Warranty ................................................................................................... 19 Three Phase Power Products or Cooling Solutions One-Year Factory Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terms of Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-transferable Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assignment of Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drawings, descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii 150/175 kVA Modular PDU Technical Specification 19 19 19 19 19 20 20 990-4806 Technical Data Model Nomenclature Modular PDU Values PD PM Distribution Type PM: Modular Power Distribution Product Type PD: Power Distribution PDPM150G6H 150 G 6 H Power (kVA) Input Voltage Line Frequency Output Voltage 150: 144kVA 175: 175kVA G: 480V L: 600V 5=50Hz 6=60Hz F=208V H=415V Power Distribution Modules Values PDM Product Type 3 Breaker Poles Power Distribution Mode Example PDM3520L2120-1040 990-4806 PDM3520L2120-1040 5 20 Number of Breaker Wires Rating (A) 1 2 3 L2120 1040 Connector Type Cable Length (cm) L5-20 L21-20 L21-30 CS50 IEC 309 60A L6-30R IEC 309 20A IEC 309 (for a complete list, see Power Distribution Module section of Accessories) 20A 30A 40A 50A 60A 3 5 Breaker Poles Number of Wires Breaker Rating (A) Connector Type Cable Length (cm) 3 5 20A L2120 1040 cm 150/175 kVA Modular PDU Technical Specification 1 Communication and Management Display Interface Normal LED Green = no alarms are present. Check Log LED Green = a new event has been added to the log. Warning LED Yellow = there are one or more active warning alarms in the system. Critical LED Red = there are one or more active critical alarms in the system. LCD Screen Displays alarms, status data, instructional help, and configuration items. UP and DOWN keys Used to scroll through menu items. ENTER Press to display new screens, open menu items, and finalize selections. ? - HELP Press to open content-sensitive help. ESC Press to return to the previous screen. Menu tree 2 150/175 kVA Modular PDU Technical Specification 990-4806 List Of Alarms • Low Output Voltage • High Module Current • Min Output Voltage • Maximum Module Current • High Subfeed Current • Modular Distribution Communication • Maximum Subfeed Current • High Total Output Current • Module Breaker Open • Max Total Output Current • High Output Voltage • Output Frequency • Max Output Voltage • Low Module Current • Subfeed Breaker Open • Minimum Module Current • Low Subfeed Current • Transformer Overheating • Minimum Subfeed Current • Low Total Output Current • Cooling Fan Failure • Min Total Output Current Network Management Card The system is equipped with one embedded network management card for remote monitoring and control of an individual Modular Power Distribution Unit (PDU) by connecting it directly to the network. 990-4806 150/175 kVA Modular PDU Technical Specification 3 pdx0420a Input and Output Contacts Note: Input Contacts are “Normally Open” Available Output Contacts: SPST, 1A@30V AST0, AST1, AST2, AST EN, EPO 24V AC/DC + ˗, and EPO CONTACT pair are reserved and not available. Wiring: 12 AWG to 30 AWG is recommended. User Interface Relay Outputs Surge withstand voltage up to 2500VAC, Surge ratings meets FCC Part 68 and Telecordia Compliance • UL - UL 60950-1, 2nd Edition, 2007- 03 -27 • (Information Technology Equipment - Safety - Part 1: General Requirements) • cUL - CSA C22.2 No. 60950-1-07, 2nd Edition, 2007 - 03 • (Information Technology Equipment - Safety - Part 1: General Requirements) • The Conditional Short-Circuit Current Rating was not evaluated by Underwriters Laboratories. 4 150/175 kVA Modular PDU Technical Specification 990-4806 Facility Planning Input Specifications PDPM150G6F PDPM150L6F Grid system 3W + G+GEC Input mains 3 Phase Connection Information: Hardwire: Max Input Conductor Size: 350MCM for Cu Cable 500MCM for Al Cable Disconnect PDPM175G6H Hardwire: Hardwire: Max Input Conductor Size: Max Input Conductor Size: 300MCM (Cu Cable Only) 350MCM for Cu Cable 500MCM for Al Cable Molded Case Circuit Breaker (MCCB) Mains Input Voltage Nominal 480V 600V 480V Nominal Current 178A 141A 214A Maximum Continuous Current with 100% Rated Circuit Breaker 180A 150A 214A 200 A 300 A 1500 A 2100 A Mains Input Current Recommended current rating of input circuit breakers 225 A Mains Input1 Inrush Currents Inrush Current2 2000 A 1 Standard circuit breakers are rated to carry 80% of their current rating continuously. 2 The supply overcurrent protective device must be able to handle the listed transformer inrush currents. Maximum Short-Circuit Withstand Rating PDPM150G6F PDPM150L6F PDPM175G6H Max Short-Circuit 65 kA 50 kA 30 kA Withstand Rating* * The Maximum Short-Circuit Withstand Rating was not evaluated by Underwriters Laboratories. Frequency Nominal 990-4806 60Hz 150/175 kVA Modular PDU Technical Specification 5 Output Specifications Grid System Number of Poles Number of PDMs Overload Protection Full Load Rating Max Continuous Current Nominal Voltage Number of Subfeeds PDPM150G6F 208/120V, 3-pole modules 72 24 yes PDPM150L6F 208/120V, 3-pole modules 72 24 yes PDPM175G6H 415/240V, 3-pole modules 72 24 yes 144KW @ 208V 144KW @ 208V 175KW @ 415V 400A 400A 243A 208Y/120 V 208Y/120 V 2 415Y/240 V PDPM150G6F External to PDU, supplied by others PDPM150L6F External to PDU, supplied by others PDPM175G6H External to PDU, supplied by others 225A 200A 300A Breakers Location OCP Rating Max Input Conductor Size Terminal: Lug Size Terminal: Cable Sizing See the Following Tables: 40° Ambient / 3CCC, 150 & 175 kW Modular PDU 30° Ambient / 3CCC, 150 & 175 kW Modular PDU Terminal Kit (included with PDU): dual lug Terminal Kit (included with PDU): single lug Terminal Kit (included with PDU): dual lug Dual Terminal: Single terminal: Dual Terminal: from 2/0 AWG to 350 kcmil max for Copper, from 1/0 AWG to 300 kcmil max, Copper only. from 2/0 AWG to 350 kcmil max for Copper, from 2/0 AWG to 500 kcmil max for Aluminum. from 2/0 AWG to 500 kcmil max for Aluminum. Recommended Conductor Sizes Note: All wiring must comply with all applicable national and or local electrical codes. Conductor sizing in this manual is based on Table 310-16 of the 2011 National Electrical Code (NEC) with the following assertions: • 90°C conductors (THHN) for 75°C termination • 3 Current Carrying Conductors for Unit Input Circuit Breaker and 4 Current Carrying Conductors for Subfeed Circuit Breaker • An ambient temperature of 30°C • Two conduits for each Subfeed • One Equipment Grounding Conductor for each conduit If the ambient room temperature is greater than 30°C, larger conductors are to be selected in accordance with the correction factors of the NEC. Equipment Grounding Conductors (EGC) are sized in accordance with NEC Article 250-122 and Table 250122. Grounding Electrode Conductors (GEC) are sized in accordance with NEC Article 250-66 and Table 250-66. 6 150/175 kVA Modular PDU Technical Specification 990-4806 The conductor sizes are recommendations for maximum configurations. Even if the load is less than the maximum rating, it is wise to plan for future load increases. If the system is operated at a lower load than its rating and it is desired to supply the system with a lower rated breaker and smaller conductors, conductor ampacities are to be selected in accordance with the NEC. The transformer inrush must betaken into account when sizing the circuit breaker. 40° Ambient / 3CCC, 150 & 175 kW Modular PDU PDPM150G6F 480:208 Cu only: 250kcmil PDPM150L6F 600:208 Cu only: 3/0 AWG 75°C conductor minimum Cu: 4 AWG 90°C conductor minimum Cu: 6 AWG Grounding Electrode Conductor (GEC) Cu: 2 AWG Cu: 2 AWG Output Supplied with Power Distribution Modules Mains Input Φ Equipment Grounding Conductor (EGC) Cu: (2) 300kcmil Φ and N, 3 AWG EGC, GEC not required. Cu: (2) 300kcmil Φ and N, 3 AWG EGC, GEC not required. 4CCC Subfeed Output PDPM175G6H 480:415 Cu: 350kcmil AL: 500kcmil 75°C conductor minimum Cu: 4 AWG Al: 2 AWG Cu: 2 AWG Al: 1/0 AWG Cu: (2) 2/0 AWG Φ and N, 4 AWG EGC, GEC not required. Al: (2) 4/0 AWG Φ and N, 2 AWG EGC, GEC not required. 90°C conductor minimum 90°C conductor minimum 75°C conductor minimum 30° Ambient / 3CCC, 150 & 175 kW Modular PDU PDPM150G6F 480:208 Cu: 4/0 AWG Mains Input Φ A1: 300kcmil 75°C conductor minimum Equipment Grounding Cu: 4 AWG Conductor (EGC) A1: 2 AWG Cu: 2 AWG Grounding Electrode Conductor (GEC) A1: 1/0 AWG Output 4CCC Subfeed Output PDPM150L6F 600:208 Cu: 3/0 AWG 90°C conductor minimum Cu: 6 AWG Cu: 2 AWG PDPM175G6H 480:415 Cu: 300kcmil Al: 400kcmil 75°C conductor minimum Cu: 4 AWG Al: 2 AWG Cu: 2 AWG Al: 1/0 AWG Supplied with Power Distribution Modules Cu: (2) 250kcmil Φ and N, Cu: (2) 250kcmil Φ and N, 3 AWG EGC, 3 AWG EGC, GEC not required. GEC not required. Cu: (2) 2/0 AWG Φ and N, 4 AWG EGC, GEC not required. Al: (2) 350 kcmil Φ and N, 1 AWG EGC, GEC not required. Al: (2) 350 kcmil Φ and N, 1 AWG EGC, GEC not required. Al: (2) 3/0 AWG Φ and N, 2 AWG EGC, GEC not required. 90°C conductor minimum 90°C conductor minimum 75°C conductor minimum Φ = phase, N = neutral (2) = two conductors per phase and neutral (when neutral is required) Subfeed is required to have two conductors per phase & N for full output due to limited wire bend space Cu= Copper conductors, Al= Aluminum conductors CCC = Current Carrying Conductor 990-4806 150/175 kVA Modular PDU Technical Specification 7 CB1 Tripping Curve Type PDPM150G6F 480:208 See ‘STR23SP’ PDPM150L6F 600:208 See ‘JLF361150C’ PDPM175G6H 480:415 See ‘STR23SP’ Merlin Gerin Square D Merlin Gerin STR23SP Merlin Gerin - Trip Units for Compact® NSJ400-NSJ600 Circuit Breakers 10 000 5 000 2 000 Ir = 0.4–1 x In 1 000 500 200 100 50 20 10 5 t(s) 2 Im = 2–9 x Ir 1 .5 .2 .1 .05 Reflex Tripping: t < 10 ms .01 .005 I = 11 x In .002 .001 .5 .7 1 2 3 4 5 7 10 20 30 50 70 100 STR23SP 06153218 .02 200 300 I / Ir 8 150/175 kVA Modular PDU Technical Specification 990-4806 JLF361150C J-Frame 150–250 A (JD, JG, JJ, and JL) Thermal-Magnetic Trip 10000 9000 8000 7000 7000 6000 6000 5000 5000 4000 4000 3000 3000 2000 2000 1500 1500 1000 900 800 1000 900 800 700 700 600 600 500 500 Circuit Breaker Prefix Continuous Ampere Rating 400 400 JD, JG, JJ, JL 150–250 2, 3 8000 9000 10000 7000 6000 5000 4000 3000 2000 800 900 1000 700 600 100 90 80 100 90 80 70 70 60 60 50 50 40 40 30 30 20 20 15 15 10 9 8 10 9 8 7 7 6 6 5 5 4 4 3 3 2 2 1.5 1.5 1 .9 .8 LIMITS LOW SETTING TIME IN SECONDS TIME IN SECONDS Number of Poles 600 All time/current characteristic curve data is based on 40°C ambient cold start. Terminations are made with conductors of appropriate length and ratings. 500 150 Maximum AC Voltage This curve is to be used for application and coordination purposes only. The EZ-AMP overlay feature at the bottom of the page should be used during coordination studies. 400 200 150 CIRCUIT BREAKER INFORMATION 150 200 JD, JG, JJ, JL MOLDED CASE CIRCUIT BREAKERS CHARACTERISTIC TRIP CURVE NO. 50-5 300 300 Curve No. 0050TC0405 June 2004 Drawing No. 48095-050-05 200 MAXIMUM SINGLE-POLE TRIP TIMES AT 25 °C BASED ON NEMA AB-4 2003 300 2011 Schneider Electric All Rights Reserved 1500 80 90 100 70 60 50 40 30 20 15 8 9 10 7 6 5 4 3 2 1.5 .8 .9 1 .7 .6 .5 MULTIPLES OF RATED CURRENT 10000 9000 8000 1 .9 .8 LIMITS HIGH SETTING .7 .7 .6 .6 .5 .5 .4 .4 .3 .3 .2 .2 .15 .15 MAGNETIC TRIP ADJUSTMENT RANGE .1 .09 .08 .1 .09 .08 .07 .07 .06 .06 .05 .05 .04 .04 MAXIMUM CLEARING TIME (AT 50 Hz) (AT 60 Hz) .03 .03 1 CYCLE (50 Hz) .02 1 CYCLE (60 Hz) .015 .02 .015 1/2 .01 .009 .008 CYCLE (50 Hz) 1/2 CYCLE (60 Hz) .007 .01 .009 .008 .007 6000 7000 5000 4000 3000 1500 8000 9000 10000 TM 250 225 200 175 150 MULTIPLES OF RATED CURRENT 2000 800 900 1000 700 600 500 400 300 200 150 80 90 100 70 60 50 40 30 20 15 8 9 10 7 6 5 4 3 2 1.5 .8 .9 1 .7 .005 .6 .006 .005 .5 .006 990-4806 150/175 kVA Modular PDU Technical Specification 9 Environmental PDPM150G6F PDPM150L6F Operating Temp -5 to +40°C (23 to 104°F) Storage Temp -25 to +65°C (-13 to 149°F) Operating Humidity 0 to 95%, non-condensing Storage Humidity 0 to 95%, non-condensing 3,000 m (9,842.5 ft) 15 000 m (50,000 ft) Max Operating Elevation Max Storage Elevation Operating Environment PDPM175G6H Protected from water and conductive contaminants. Storage Environment Full Load Heat Loss @ Nominal Mains Airflow/Cooling Requirement Protected from water and conductive contaminants. 3.128 kW/hr 3.272 kW/hr 3.441 kW/hr (10672.7 BTU/hr) (11164.1 BTU/hr) (11740.7 BTU/hr) Front to rear airflow Transformer Specifications PDPM150G6F PDPM150L6F PDPM175G6H 150kVA Isolated Transformer Delta/Wye 150kVA Isolated Transformer Delta/Wye 175kVA Isolated Transformer Delta/Wye Input Voltage 480V 600V 480V Input Current 180A 150A 214A Size Type Configuration Inrush Current Not to exceed 10X Nominal Input Current Per Phase Output Voltage 208Y/120V 208Y/120V 415Y/240V Output Current 400A 400A 243A Thermal Sensing 180°C 900 lb (409 kg) 3 - 6% 180°C 900 lb (409 kg) 3 - 6% 180°C 1232 lb (560 kg) 3 - 6% 60 Hz 60 Hz 60 Hz 57-63Hz 57-63Hz 57-63Hz <55db @ Im <55db @ Im <55db @ Im Weight Impedance in %IZ Frequency Frequency Range Noise Copper - Each coil to be made from a continuous conductor (wire or foil). Windings 10 Insulation rating 180°C 180°C 180°C Efficiency >98.2% >98.2% >98.5% 150/175 kVA Modular PDU Technical Specification 990-4806 Dimensions PDPM150G6F PDPM150L6F PDPM175G6H Unpackaged Dimensions (H × W × D) 79.0 x 23.6 x 42.1 in. (2007 x 600 x 1069 mm) 79.0 x 23.6 x 42.1 in. (2007 x 600 x 1069 mm) 79.0 x 23.6 x 42.1 in. (2007 x 600 x 1069 mm) Shipping Dimensions (H x W x D) 84.8 x 40 x 48.0 in. 84.8 x 40 x 48.0 in. 84.8 x 40 x 48.0 in. (2153 x 1016 x 1219 mm) (2153 x 1016 x 1219 mm) (2153 x 1016 x 1219 mm) Weight (Unpopulated PDU) 1843.1 lb (836 kg) 1942.3 lb (881 kg) 2074.6 lb (941 kg) Shipping weight (Unpopulated PDU) 1944.5 lb (882 kg) 2043.7 (927 kg) 2176.0 lb (987 kg) Free space around PDU: Minimum Recommended Front Service Clearance* 42.0 in. (1066.8 mm) Minimum Recommended Rear Service Clearance* 36 in. (914.4 mm) Right: 24 in. (609.6 mm) Left: None Required Side Clearance* Minimum Top Ventilation Clearance* 8.25 in. (210 mm) * In establishing and verifying proper clearance, ensure full compliance with all applicable national, state, and local electrical codes. Color Black Input Power Entry Cable Route (Top, Bottom, Both) Top Top Top Output Power Exit Cable Route (Top, Bottom, Both) Top Top Top Conduit Size Size of Roof Hole or Bottom Plate for Conduit 990-4806 Defined by input wiring Hole is punched by customer according to conduit size. 150/175 kVA Modular PDU Technical Specification 11 Drawings Note: These drawings are for reference ONLY - subject to change without notice. Note: A comprehensive set of drawings is available on the APC Web site: www.apc.com 12 150/175 kVA Modular PDU Technical Specification 990-4806 DEVISE RATING (100% Rated) 4 POLE BREAKER 3 POLE BREAKER TYPE MAKE MODEL NJHF36400E20 (100% Rated) 400A, 600V MERLIN GERIN S EE NOTE 7 400A, 600V 3 POLE BREAKER SCHNEIDER ELECTRIC UIB 400A, 600V POWER DISTRIBUTION MODULE MOB SUBFEED BREAKER 400V NJHF36400E20 MERLIN GERIN (100% Rated) NJHS46400E20 MERLIN GERIN (100% Rated) MODULE-X 65kA SYMMETRICAL RATED SHORT CIRCUIT CURRENT 65kA SYMMETRICAL 65kA SYMMETRICAL 10kA SYMMETRICAL 13 150/175 kVA Modular PDU Technical Specification 990-4806 DEVISE 400A, 600V 150A, 600V RATING (100% Rated) 4 POLE BREAKER 3 POLE BREAKER TYPE POWER DISTRIBUTION MODULE 3 POLE BREAKER UIB 400V 400A, 600V MOB SUBFEED BREAKER MODULE-X MAKE MODEL SEE NOTE 7 JLF36150CYE SQUARE D (100% Rated) NJHS46400E20 MERLIN GERIN (100% Rated) NJHF36400E20 MERLIN GERIN (100% Rated) SCHNEIDER ELECTRIC RATED SHORT CIRCUIT CURRENT 50kA SYMMETRICAL 65kA SYMMETRICAL 65kA SYMMETRICAL 10kA SYMMETRICAL 990-4806 150/175 kVA Modular PDU Technical Specification 14 MOB UIB DEVISE 400A, 600V 400A, 600V 400A, 600V RATING (100% Rated) POWER DISTRIBUTION MODULE 3 POLE BREAKER 4 POLE BREAKER 3 POLE BREAKER TYPE SCHNEIDER ELECTRIC MERLIN GERIN MAKE SUBFEED BREAKER 240V MODEL SEE NOTE 7 NJHF36400E20 MERLIN GERIN (100% Rated) NJHS46400E20 MERLIN GERIN (100% Rated) NJHF36400E20 (100% Rated) MODULE-X RATED SHORT CIRCUIT CURRENT 65kA SYMMETRICAL 65kA SYMMETRICAL 65kA SYMMETRICAL 10kA SYMMETRICAL 15 150/175 kVA Modular PDU Technical Specification 990-4806 Options Hardware Options Power Distribution Modules The following APC Power Distribution Modules (PDMs) are intended for, and can be installed in the following 208V Modular PDUs: APC Modular Power Distribution Units PDPM150G6F PDPM150L6F APC Power Distribution Modules for 208V Modular PDUs 208V Power Distribution Modules have black buss plates which match the black 208V PDU backplane. These PDMs require one (1) Modular PDU slot position. # cords Voltage Amperage (Qty) Circuit Breakers PDM1320L5-3P-x 3 120V 20A (3) 1P PDM3520L2120-xxx 1 120V 20A (3) 1P PDM3530L2130-xxx 1 120V 30A (3) 1P PDM3450CS50-xxx 1 208V 50A (1) 3P PDM3460IEC309-xxx 1 208V 60A (1) 3P PDM2330L6-xx-yyy 1 208V 30A (1) 2P Module (Qty) Connector (3) 3-wire NEMA L5-20R (1) 5-wire NEMA L21-20 (1) 5 wire NEMA L21-30 (1) 4 wire CS50 (1) 4 wire (3P+PE) IEC 309 60A (1) 3 wire NEMA L6-30R Notes: Input frequency: 50/60Hz Certifications: UL Listed Cable rating of Power Distribution Modules: TC-ER, DP-1. Approved for under floor usage per NFPA 645.5(E) and 645.5(E)(3) when used in a designated IT Site as defined in NFPA Article 645, Information Technology Equipment. The PDM3460IEC309-xxx PDMs use a 4-wire IEC 309 connector with a 9 o'clock ground position. Unless otherwise noted, 1-cord Power Distribution Modules are available with these cord lengths: 200, 260, 320, 380, 440, 500, 560, 620, 680, 740, 800, 860, 920, 980, 1040, 1680 Unless otherwise noted, all 3-cord Power Distribution Modules are available with these cord lengths: Option 1: PDM with 260, 380, and 500 cm cables Option 2: PDM with 680, 860, and 1040 cm cables Option 3: PDM with three 1680 cm cables 16 150/175 kVA Modular PDU Technical Specification 990-4806 Power Distribution Modules continued The following APC Power Distribution Modules (PDMs) are intended for and can be installed in the following 415V Modular PDUs: APC Modular Power Distribution Units PDPM175G6H APC Power Distribution Modules for 415V Modular PDUs 415V Power Distribution Modules have gray buss plates which match the gray 415V PDU backplane. These PDMs require one (1) Modular PDU slot position. # cords Voltage Amperage (Qty) Circuit Breakers PDM1320IEC-3P-x 3 240V 20A (3) 1P PDM3520IEC309-xxx* 1 240V 20A (3) 1P PDM3540IEC309-xxx 1 240V 40A (3) 1P Module (Qty) Connector (3) 3-wire IEC 309 20A (1) 5-wire IEC 309 (1) 5-wire IEC 309 Notes: Input frequency: 50/60Hz Certifications: UL Listed Cable rating of Power Distribution Modules: TC-ER, DP-1. Approved for under floor usage per NFPA 645.5(E) and 645.5(E)(3) when used in a designated IT Site as defined in NFPA Article 645, Information Technology Equipment. The PDM3520IEC309-xxx and PDM3540IEC309-xxx PDMs use a 5-wire IEC 309 connector with a 6 o'clock ground position. Unless otherwise noted, 1-cord Power Distribution Modules are available with these cord lengths: 200, 260, 320, 380, 440, 500, 560, 620, 680, 740, 800, 860, 920, 980, 1040, 1680 Unless otherwise noted, all 3-cord Power Distribution Modules are available with these cord lengths: Option 1: PDM with 260, 380, and 500 cm cables Option 2: PDM with 680, 860, and 1040 cm cables Option 3: PDM with three 1680 cm cables *PDM3520IEC309-xxx is also available with 80 and 140 cm cord lengths 990-4806 150/175 kVA Modular PDU Technical Specification 17 Seismic Kit Seismic Kit for 300mm Symmetra PX 100, Symmetra PX 250/500, and Modular PDU Frames SYOPT600 Bottom Feed Side Cars Compatible PDUs SKU Description PDPM100SC APC Symmetra PX 100kW Bottom Feed Side Car, 300mm PDPM175G6H PDPM150SC APC 150KVA Modular PDU Bottom Feed Side Car, 300mm PDPM150G6F PDPM150L6F Shunt Trip Square D shunt trip unit models for field installation: S29384 for 24VAC S29382 for 12VAC S29390 for 24VDC S29391 for 30VDC Configuration Options • StruxureWare Data Center Expert • Network Manageable • Seismic bracket kits available • Optional Bottom Feed Side Car for bottom feed input/output 18 150/175 kVA Modular PDU Technical Specification 990-4806 Warranty SCHNEIDER ELECTRIC IT CORPORATION LIMITED FACTORY WARRANTY Three Phase Power Products or Cooling Solutions One-Year Factory Warranty1 The limited warranty provided by Schneider Electric IT Corporation (SE IT) in this Statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business. Terms of Warranty SE IT warrants that the product shall be free from defects in materials and workmanship for a period of one year from the date of product start-up when start-up is performed by SE IT authorized service personnel and occurs within six months of The SE IT shipment date. This warranty covers repairing or replacing any defective parts including on-site labor and travel. In the event that the product fails to meet the foregoing warranty criteria, the warranty covers repairing or replacing defective parts at the sole discretion of SE IT for a period of one year from the shipment date. For SE IT cooling solutions, this warranty does not cover circuit breaker resetting, loss of refrigerant, consumables, or preventive maintenance items. Repair or replacement of a defective product or part thereof does not extend the original warranty period. Any parts furnished under this warranty may be new or factory-remanufactured. Non-transferable Warranty This warranty is extended to the first person, firm, association or corporation (herein referred to by “You” or “Your”) for whom the SE IT product specified herein has been purchased. This warranty is not transferable or assignable without the prior written permission of SE IT. Assignment of Warranties SE IT will assign you any warranties which are made by manufacturers and suppliers of components of the SE IT product and which are assignable. Any such warranties are assigned “AS IS” and SE IT makes no representation as to the effectiveness or extent of such warranties, assumes no responsibility for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components. Drawings, descriptions SE IT warrants for the warranty period and on the terms of the warranty set forth herein that the SE IT product will substantially conform to the descriptions contained in the SE IT Official Published Specifications or any of the drawings certified and agreed to by contract with SE IT if applicable thereto (“Specifications”). It is understood that the Specifications are not warranties of performance and not warranties of fitness for a particular purpose. 1 To determine which factory warranty applies to the SE IT product you purchased, please consult the factory warranties located on the SE IT web site: www.apc.com/products 990-4806 150/175 kVA Modular PDU Technical Specification 19 Exclusions SE IT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation or testing. Further SE IT shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installation, start-up by non-SE IT designated personnel, a change in location or operating use, exposure to the elements, Acts of God, fire, theft, or installation contrary to SE IT recommendations or specifications or in any event if the SEIT serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. SE IT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. SE IT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SE IT RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SE IT SOLE LIABILITY AND PURCHASER’S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SE IT WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL SE IT, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SE IT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES, SPECIFICALLY, SE IT IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NO SALESMAN, EMPLOYEE OR AGENT OF SE IT IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN SE IT OFFICER AND LEGAL DEPARTMENT. Warranty Claims Customers with warranty claims issues may access the SE IT worldwide customer support network through the SE IT web site: support.apc.com. Select your country from the country selection pull-down menu. Open the Support tab at the top of the web page to obtain contact information for customer support in your region. 20 150/175 kVA Modular PDU Technical Specification 990-4806 Worldwide Customer Support Customer support is available at no charge via e-mail or telephone. Contact information is available at www.apc.com/support/contact. © 2013 Schneider Electric, APC and the APC logo are owned by Schneider Electric Industries S.A.S., or its affiliated companies. All other trademarks are property of their respective owners. 990-4806 8/2013
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Language : en XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Creator Tool : FrameMaker 11.0.2 Modify Date : 2013:08:27 13:42:24-05:00 Create Date : 2013:08:27 13:34:20Z Metadata Date : 2013:08:27 13:42:24-05:00 Format : application/pdf Title : untitled Producer : Acrobat Distiller 10.1.7 (Windows) Document ID : uuid:78e0024e-25cc-45f3-a9bc-a5c49d304ced Instance ID : uuid:e0fad004-77b2-4513-aa9c-b483273e2962 Page Mode : UseOutlines Page Count : 26 Creator : FrameMaker 11.0.2EXIF Metadata provided by EXIF.tools