12 Clintonville Road Northford, CT 06472 Phone (203) 484-7161 FAX: (203) 484-7118 MS-5210UD/MS-5210UDE Fire Control Communicator Programming, Installation, Maintenance and Operating Instruction Manual Document 5/2/97 #50193 Rev. P/N 50193:D © 1997 Fire•Lite D ECN 97-173 Installation Precautions - Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is energized. Do not attempt to install, service, or operate this unit until this manual is read and understood. CAUTION - System Reacceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 721993 Chapter 7 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. This system meets NFPA requirements for operation at 0-49O C/32-120O F and at a relative humidity of 85% RH (non-condensing) at 30O C/86 O F. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a nominal room temperature of 15-27O C/60-80O F. Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a 10% I.R. drop from the specified device voltage. Fire Alarm System Limitations Like all solid state electronic devices, this system may operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely immune from lightning transients and interferences, proper grounding will reduce susceptibility. Overhead or outside aerial wiring is not recommended, due to an increased susceptibility to nearby lightning strikes. Consult with the Technical Services Department if any problems are anticipated or encountered. Disconnect AC power and batteries prior to removing or inserting circuit boards. Failure to do so can damage circuits. Remove all electronic assemblies prior to any drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, and printed circuit board location. Do not tighten screw terminals more than 9 in-lbs. Over tightening may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal. This system contains static-sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. Use static suppressive packaging to protect electronic assemblies removed from the unit. Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment. FACP operation and reliability depend upon proper installation. While installing a fire alarm system may make lower insurance rates possible, it is not a substitute for fire insurance! An automatic fire alarm system - typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control with remote notification capability can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. Any fire alarm system may fail for a variety of reasons: Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second floor detector, for example, may not sense a first floor or basement fire. Furthermore, all types of smoke detectors - both ionization and photoelectric types, have sensing limitations. No type of smoke detector can sense every kind of fire caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signaling, and/or power. If detectors are not so located, a developing fire may damage the alarm system, crippling its ability to report a fire. Audible warning devices such as bells may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. A fire alarm system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time. Rate-of-Rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Equipment used in the system may not be technically compatible with the control. It is essential to use only equipment listed for service with your control panel. Telephone lines needed to transmit alarm signals from a premise to a central monitoring station may be out of service or temporarily disabled. The most common cause of fire alarm malfunctions, however, is inadequate maintenance. All devices and system wiring should be tested and maintained by professional fire alarm installers following written procedures supplied with each device. System inspection and testing should be scheduled monthly or as required by National and/or local fire codes. Adequate written records of all inspections should be kept. FCC Warning WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which is designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his own expense. Technical Publishing Canadian Requirements This digital apparatus does not exceed the Class A limits for radiation noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. Document PRECAULG.PM6 12/31/96 Table of Contents CHAPTER 1: Product Description ......................................................................................................................... 8 1.1: Product Features .......................................................................................................................................... 8 FIGURE 1-1: Optional DP-5210UD.................................................................................................... 9 FIGURE 1-2: MS-5210UD Panel ........................................................................................................ 10 1.2: Specifications .............................................................................................................................................. 11 1.3: Controls and Indicators ............................................................................................................................... 12 FIGURE 1-3: Display and Keypad ...................................................................................................... 12 1.4: Circuits ........................................................................................................................................................ 12 1.5: Digital Communicator................................................................................................................................. 13 1.6: Components................................................................................................................................................. 14 FIGURE 1-4: Transformer Assemblies ............................................................................................... 14 1.7: Optional Modules ........................................................................................................................................ 15 1.8: Optional Accessories................................................................................................................................... 15 FIGURE 1-5: BB-17F Battery Box ..................................................................................................... 15 FIGURE 1-6: LED-10 Series Annunciator ..........................................................................................16 FIGURE 1-7: AFM-16ATX................................................................................................................. 16 FIGURE 1-8: AFM-16ATF ................................................................................................................. 17 FIGURE 1-9: AFM-16AF.................................................................................................................... 17 FIGURE 1-10: LDM-32F Module ....................................................................................................... 17 FIGURE 1-11: FCPS-24F(E)............................................................................................................... 18 1.9: Telephone Requirements and Warnings ...................................................................................................... 18 1.9.1: Telephone Circuitry:.......................................................................................................................... 18 1.9.2: Digital Communicator: ..................................................................................................................... 19 1.9.3: Telephone Company Rights and Warnings: ...................................................................................... 19 1.9.4: For Canadian Applications................................................................................................................ 19 CHAPTER 2: Installation ................................................................................................................................ ......... 21 2.1: Mounting Options ....................................................................................................................................... 21 2.2: Backbox Mounting ...................................................................................................................................... 21 FIGURE 2-1: Cabinet Dimensions and Knockout Locations.............................................................. 22 FIGURE 2-2: FACP Backbox and Battery Box .................................................................................. 23 2.3: Operating Power.......................................................................................................................................... 24 FIGURE 2-3: Operating Power Connections....................................................................................... 24 2.4: Input Circuits............................................................................................................................................... 25 FIGURE 2-4: Style B Initiating Device Circuit Connections.............................................................. 26 2.5: Output Circuits ............................................................................................................................................ 26 FIGURE 2-5: Auxiliary Power Connections ....................................................................................... 26 FIGURE 2-6: Notification Appliance Circuit Connections................................................................. 27 FIGURE 2-7: Programmable Relay Terminals.................................................................................... 27 2.6: Digital Communicator................................................................................................................................. 28 FIGURE 2-8: Wiring Phone Jacks....................................................................................................... 28 2.7: UL Power-limited Wiring Requirements .................................................................................................... 29 FIGURE 2-9: Typical Wiring Diagram for UL Power-limited Requirements .................................... 29 2.8: Installation of Optional Modules................................................................................................................. 29 FIGURE 2-10: Installation of CAC-10F Module ................................................................................ 30 FIGURE 2-11: Wiring NACs and IDCs for Class A Operation .......................................................... 30 FIGURE 2-12: Installation and Wiring of NAC-REM Module .......................................................... 31 FIGURE 2-13: Remote Printer Connections ....................................................................................... 32 TABLE 2-1: Printer Settings................................................................................................................ 32 FIGURE 2-14: LED-10IM Installation................................................................................................ 33 FIGURE 2-15: Wiring LED-10IM to LED-10 Series ......................................................................... 33 FIGURE 2-16: ABS-8R Enclosure ...................................................................................................... 34 FIGURE 2-17: Wiring LED-10IM to ACM-8RF ................................................................................ 34 3 Table of Contents FIGURE 2-18: Wiring LED-10IM to LDM-32F .................................................................................35 FIGURE 2-19: Wiring LED-10IM to AFM-16ATX ...........................................................................36 CHAPTER 3: Programming Instructions ............................................................................................................... 37 3.1: Entering Program Mode ..............................................................................................................................37 3.2: Switch Functions .........................................................................................................................................38 FIGURE 3-1: Control Panel Keypad ...................................................................................................38 3.3: Program Options..........................................................................................................................................38 3.3.1: Level 1 - Main Panel Options............................................................................................................38 TABLE 3-1: Zone Functions ...............................................................................................................42 TABLE 3-2: Event Code Changes for ID Contact Format ..................................................................44 FIGURE 3-2: Verification Timing Diagram........................................................................................45 3.3.2: Level Two - Event Codes/Transmission Formats..............................................................................47 TABLE 3-3: Event Codes, Primary Central Station Number ..............................................................48 TABLE 3-4: Event Codes, Primary Central Station Number ..............................................................50 TABLE 3-5: Event Codes, Primary Central Station Number ..............................................................53 TABLE 3-6: Event Codes, Secondary Central Station Number ..........................................................55 TABLE 3-7: Event Codes, Secondary Central Station Number ..........................................................57 TABLE 3-8: Event Codes, Secondary Central Station Number ..........................................................60 3.3.3: Level Three - Option Module Selections ..........................................................................................62 3.3.4: Level Four - Upload/Download Option.............................................................................................64 3.3.5: Default Programming ........................................................................................................................66 CHAPTER 4: Operating Instructions ..................................................................................................................... 67 FIGURE 4-1: New and Old Keypad/Display.......................................................................................67 4.1: Switch Functions in Normal Mode..............................................................................................................67 4.2: LED Display and Status LEDs ....................................................................................................................69 FIGURE 4-2: Phone Connectors and LEDs.........................................................................................70 4.3: Operation .....................................................................................................................................................71 4.3.1: Fire Alarm Response .........................................................................................................................71 4.3.2: Fire Alarm Restoral ...........................................................................................................................72 4.3.3: System Supervisory Condition Response .........................................................................................72 4.3.4: System Supervisory Restoral Response ............................................................................................72 4.3.5: Trouble Condition Response .............................................................................................................73 4.3.6: Trouble Condition Restoral ...............................................................................................................74 4.3.7: Process Monitored Alarm Response .................................................................................................74 4.3.8: Process Monitored Alarm Restoral ...................................................................................................74 4.3.9: OFF Normal Reporting .....................................................................................................................75 4.3.10: Zone Disable/Enable .......................................................................................................................75 4.3.11: NAC (bell) Disable/Enable..............................................................................................................75 4.3.12: Fire Drill ..........................................................................................................................................76 4.4: Central Station Communications.................................................................................................................76 TABLE 4-1: Format Selection Addresses (16+42) Programming Level 1..........................................77 TABLE 4-2: Format Selection Address Explanation...........................................................................78 4.4.1: Transmittal Priorities .........................................................................................................................79 TABLE 4-3: Compatible UL Listed Receivers....................................................................................80 CHAPTER 5: Servicing ................................................................................................................................ ............ 81 5.1: Walk Test Mode...........................................................................................................................................81 5.2: History Mode...............................................................................................................................................82 TABLE 5-1: History Mode Messages..................................................................................................83 5.3: Troubleshoot Mode......................................................................................................................................84 5.3.1: Zones .................................................................................................................................................84 5.3.2: AC Line .............................................................................................................................................85 5.3.3: Battery ...............................................................................................................................................85 4 Table of Contents 5.3.4: Telephone Lines ................................................................................................................................ 85 FIGURE 5-1: Handset/Speaker Connection ........................................................................................ 85 5.3.5: NACs 1, 2, 3 and 4 ............................................................................................................................ 86 5.3.6: Resettable Power ............................................................................................................................... 86 5.4: Lamp Test .................................................................................................................................................... 86 5.5: Print Mode................................................................................................................................................... 86 5.6: Printer Output .............................................................................................................................................. 87 CHAPTER 6: Remote Site Upload/Download ........................................................................................................ 88 6.1: Downloading Program: General.................................................................................................................. 88 6.1.1: Security Features ............................................................................................................................... 89 6.2: Downloading Initiated at Control Panel ...................................................................................................... 90 6.3: Downloading Initiated at a Service Terminal .............................................................................................. 91 6.4: Uploading Initiated at a Service Terminal................................................................................................... 91 6.5: Simultaneous Data Transfers....................................................................................................................... 92 Appendix A: Battery Calculations ....................................................................................................................... 93 TABLE A-1: Battery Calculation ....................................................................................................... 93 A.1: Main Power Supply ................................................................................................................................... 94 TABLE A-2: Regulated Load in Standby @24 VDC . ............................................................................. 94 TABLE A-3: Regulated Load in Alarm @24 VDC . ................................................................................ 95 Appendix B: Main Panel Options Program Sheets ............................................................................................ 96 Appendix C: Event Codes/Transmission Format Programming Sheets .......................................................... 101 Appendix D: Ademco Contact ID Format Event Code Descriptions ............................................................... 111 Appendix E: Option Modules Programming Sheets .......................................................................................... 116 Appendix F: Upload/Download Program Sheets ................................................................................................ 118 Appendix G: Wire Requirements ........................................................................................................................ 119 TABLE 6-1: Wire Requirements ......................................................................................................... 119 Appendix H: Operation and Function Modes .................................................................................................... 120 TABLE 6-2: OPERATION MODES................................................................................................... 120 TABLE 6-3: FUNCTION MODES ..................................................................................................... 120 5 This control panel has been designed to comply with standards set forth by the following regulatory agencies: • Underwriters Laboratories Standard UL 864 • NFPA 72 National Fire Alarm Code • CAN/ULC - S527-M87 Standard for Control Units for Fire Alarm Systems Before proceeding, the installer should be familiar with the following documents. NFPA Standards This Fire Alarm Control Panel complies with the following NFPA Standards: NFPA 72 National Fire Alarm Code for Central Station Signaling Systems Protected Premises Unit (Automatic, Manual and Waterflow), Local Fire Alarm Systems and Remote Station Fire Alarm Systems. Underwriters Laboratories Documents: UL 38 Manually Actuated Signaling Boxes UL 217 Smoke Detectors, Single and Multiple Station UL 228 Door Closers–Holders for Fire Protective Signaling Systems UL 268 Smoke Detectors for Fire Protective Signaling Systems UL 268A Smoke Detectors for Duct Applications UL 346 Waterflow Indicators for Fire Protective Signaling Systems UL 464 Audible Signaling Appliances UL 521 Heat Detectors for Fire Protective Signaling Systems UL 864 Standard for Control Units for Fire Protective Signaling Systems UL 1481 Power Supplies for Fire Protective Signaling Systems UL 1638 Visual Signaling Appliances UL 1971 Signaling Devices for Hearing Impaired CAN/ULC - S524-M91 Standard for Installation of Fire Alarm Systems Other: NEC Article 250 Grounding NEC Article 300 Wiring Methods NEC Article 760 Fire Protective Signaling Systems Applicable Local and State Building Codes Requirements of the Local Authority Having Jurisdiction (LAHJ) Fire•Lite Documents Fire•Lite Device Compatibility Document Document #15384 Annunciator Modules Document #15390 AFM-16ATF Annunciator Document #15970 AFM-16AF Annunciator Document #15210 FCPS-24F Field Charger/Power Supply Document #50079 LDM Series Lamp Driver Modules Document #50055 LED-10 Annunciator Document #50361 ACM-8RF Annunciator Control Relay Module Document #50362 PK-5210UD Manual Document #50363 Document #50193 Rev. D 5/2/97 P/N 50193:D 6 MS-5210UD Terminals and Connectors Document #50193 Rev. D 5/2/97 P/N 50193:D 7 Product Description CHAPTER 1 Product Description The MS-5210UD is a combination control panel and digital communicator all on one circuit board. It is a 10-zone panel, which uses conventional input devices. The panel accepts waterflow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include two Notification Appliance Circuits (NACs) expandable to four, two programmable Form-A relays (option module with two Form-C relays can be added), EIA-485 port to interface with remote annunciators and optional remote relay modules plus a printer port. The integral communicator transmits system status (alarms, troubles, AC loss, others) to UL-listed central stations via the public switched telephone network. The control panel has a built-in programmer. It also supervises all wiring, AC voltage, telephone line input voltage/current and battery level. The control panel may be programmed or interrogated off site via the public switched telephone network. Any IBM compatible personal computer with Windows™ 3.1 or greater, with a 1200 baud Hayes™ compatible modem and Fire•Lite Upload/Download software P/N PK-5210UD, may serve as a Service Terminal. This allows downloading of any portion or all of the program and upload of any portion or all of the program, history file, walktest data, current status and system voltages. The MS-5210UDE offers the same features as the MS-5210UD but allows connection to 220/240 VAC input. Note that unless otherwise specified, the term MS-5210UD shall be used in this manual to refer to both the MS-5210UD and the MS-5210UDE Fire Control Communicators. 1.1 Product Features • Selectable as Local Fire Panel of Fire Panel/Communicator • Programmable Zone ID: 2-Wire Smoke; Pull Station; Normally-Open Contact; Supervisory; Supervisory Auto-resettable; Waterflow (silenceable); Waterflow (nonsilenceable); Remote Switch for Reset, Silence, Acknowledge and Drill; Standard and Auto-reset Critical and Noncritical Process Monitoring • 10 Style B (Class B) Initiating Device Circuits (IDCs) • Two NFPA Style Y (Class B) Notification Appliance Circuits (NACs) • CAC-10F Option Module to convert all 10 IDCs to Style D (Class A) and convert two Style Y (Class B) NACs to Style Z (Class A) • • • • • • • • • • • • 8 3.6 amps of system power expandable to 6.6 amps Remote Relay Option Module (ACM-8RF) providing one 5.0 amp relay per zone Built-in Programmer Built-in Voltmeter Telephone Line Active LED Indicators Communication Confirmation (Kissoff) LED Disable report by event Programmable Event Codes 24 Volt Operation Real Time Clock and Calendar Trouble Reminder Alarm Verification Document #50193 Rev.D 5/2/97 P/N 50193:D Product Features • Interfaces with Fire•Lite annunciators (requires LED-10IM Option Module) LED Series Remote Annunciator provides one red alarm and one yellow trouble LED per zone LDM-32F Graphic Annunciator AFM Series LED Annunciators • • • • • • • • • • • • • • • • • Small Size 16.900" (42.9 cm) X 14.500" (36.8 cm) X 4.625" (11.8 cm) History File with 256 Event Storage Silence Inhibit per Notification Appliance Circuit Auto-Silence per Notification Appliance Circuit Touchtone/Rotary Dialing per telephone line Programmable Make/Break Ratio Fuseless Design Printer Interface Module (PRT-24) NAC-REM Option Module adds two Form-C relays and two Style Z (Class A) NACs Print Real-time System Status Print History, Walktest Files, Program Contents and Troubleshoot mode voltages PK-5210UD Upload/Download Software Kit Number of dial attempts (5 minimum, 10 maximum) Programmable Zone Delay (waterflow only) Low AC Voltage Sense One-man silent or audible Walktest Optional Dead Panel Coverplate (DP-5210UD) FIGURE 1-1: Optional DP-5210UD Document #50193 Rev. D 5/2/97 P/N 50193:D 9 Product Features FIGURE 1-2: MS-5210UD Panel 24 VDC Power Notification Programmable Appliance Relays Circuits Class A Converter Module 10 Input Zones LED-10IM Interface Module Connector Transformer Printer Interface Module Connector NAC-REM Expander Module PROM (U14)1 Four Character 7-Segment LED Display Primary & Secondary Phone Lines Transformer Keypad Holds up to 12 AH Batteries, Up to 60 Hrs. of Standby 1 Software for the Fire Control Communicator is located in a PROM inserted in the IC socket labeled U14. The MS-5210UD and MS-5210UDE each contain unique software. For specific panel software information, refer to the MS-5210UD/MS-5210UDE Field Software Change Procedure Document #50479. 10 Document #50193 Rev.D 5/2/97 P/N 50193:D Specifications 1.2 Specifications AC Power - TB1 MS-5210UD: 120 VAC, 60 Hz, 2.3 amps MS-5210UDE: 220/240 VAC, 50 Hz, 1.2 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation Battery (lead acid only) - J1 Maximum Charging Circuit: Normal Flat Charge—27.6V @ 0.8 amp Maximum Charger Capacity: 17 Amp Hour battery (MS-5210UD cabinet holds maximum 12 Amp Hour battery. Larger batteries require Fire•Lite BB-17F or other UL listed battery cabinet) Initiating Device Circuits TB5 and CAC-10F Option Module Detector Zones 1 through 10 Power-limited Circuitry Operation: All zones NFPA Style B - Convert to Style D using CAC-10F Class A Converter Module Normal Operating Voltage: 24 VDC (ripple = 100 mV maximum) Alarm Current: 15 mA Short Circuit Current: 42 mA maximum Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.7K, ½ watt (Part #27072 UL listed) Detector Loop Current is sufficient to ensure operation of one alarmed detector per zone Standby Current: 7.26 mA (includes ELR and 2 mA maximum detector current) Smoke Detector Identifier A Refer to Fire•Lite Device Compatibility Chart for listed compatible devices. Notification Appliance Circuits - TB4 & NAC-REM Option Module (TB2 & TB3) Nonregulated special purpose power, Styles Y & Z supported Power-limited circuitry Operating Voltage Nominal 24 volts Current for all external devices: 3.0 amps expandable to 6.0 amps Current Limit: TB4 via electronic protection, NAC-REM option module (TB2 & TB3) via PTC Maximum signaling current/circuit: TB4 = 3.0 amps. NAC-REM = 1.5 amps. End-of-Line resistor: 4.7K, ½ watt (Part #71252 UL listed) for Notification Appliance Circuits Refer to Fire•Lite Device Compatibility Chart for listed compatible devices Form-A Relays - TB3 TB3 contact rating: 2.0 amps @ 30 VDC (resistive), 5.0 amps @ 125 VAC (resistive) NAC-REM Form-C contact rating: 2.0 amps @ 30 VDC, 0.6 amps @ 125 VAC (resistive) Four-wire Smoke Detector Power - TB2 Terminals 3(+) &4(-) Maximum ripple voltage: 10 mVRMS Operating Voltage nominal 24 volts Up to 500 mA is available for powering 4-wire smoke detectors Power-limited Circuitry. Recommended maximum Standby current is 50 mA1 Refer to Fire•Lite Device Compatibility Chart for compatible listed devices 1. For power supply and battery calculations, refer to Appendix A. Document #50193 Rev. D 5/2/97 P/N 50193:D 11 Controls and Indicators Nonresettable Regulated 24 VDC Power - TB2 Terminals 1(+) & 2(-) Maximum ripple voltage: 10 mVRMS Operating Voltage nominal 24 volts Total DC current available from this output is up to 500 mA Power-limited Circuitry. Recommended maximum Standby current is 150 mA1 Refer to Fire•Lite Device Compatibility Chart for compatible listed devices 1.3 Controls and Indicators Front Panel Switches FIGURE 1-3: Display and Keypad RESET SILENCE MODE Up Arrow (ACK) Down Arrow (ACK) 1st EVENT ENTER/STORE Digits 0 through 9 Letters A through F Displays Alarm - red LED Trouble - yellow LED Supervisory - yellow LED AC Power - green LED Four, Seven Segment Displays - red Primary Phone Line Active - red LED Secondary Phone Line Active - red LED 'Kissoff' Signal from Central Station - green LED Silence - yellow LED Modem - green LED Local Sounder A piezo sounder provides separate and distinct sounds for alarm, trouble, supervisory and critical process monitoring conditions 1.4 Circuits Input Circuits Ten input circuits provide Style B (Class B) configuration standard and may be converted to Style D (Class A) by installing the CAC-10F module. Input circuits may be used as standard fire control panel zones, remote input switches (Acknowledge, Silence, Drill, Reset) or as standard or auto-resettable critical and noncritical process 1. Total current for nonresettable power, four-wire smoke power, and four Notification Appliance Circuits must not exceed 6.0 amps. Total system current in excess of 3.6 amps requires the XRM-24 Transformer (XRM-24E for 220/240 VAC applications) and 12 Amp Hour or 17 Amp Hour batteries. 12 Document #50193 Rev.D 5/2/97 P/N 50193:D Digital Communicator monitoring. All ten Initiating Device Circuits accept Normally-Open contact devices and two-wire smoke detectors. Output Circuits • • • • • • • 24 Volt Resettable Power Output 500 mA 24 Volt Nonresettable Power Output 500 mA Primary Telephone Line Secondary Telephone Line 24 Volt Battery Charger (up to 17 AH batteries) Printer Port EIA-485 Port (interfaces to LED-10 Annunciator, AFM Series and LDM Graphic Series Annunciators and ACM-8RF Remote Relay Module) Notification Appliance Circuits Two Notification Appliance Circuits Style Y (Class B) configurable for Style Z (Class A) using the CAC-10F option module. Relays Two dry Form-A relay contacts programmable for system alarm, system trouble, system supervisory (standard and autoresettable), standard and autoresettable process monitoring or communications failure are provided. Contacts are rated 2.0 amps @ 30 VDC (resistive). Two additional Form-C relay contacts programmable for alarm, trouble, standard and autoresettable supervisory, standard and autoresettable process monitoring or communications fail are available using the NAC-REM (NAC/Relay) option module. Contacts are rated 2.0 amps @ 30 VDC and 0.6 amps at 125 VAC (resistive). Printer Port EIA-232 compatible, fully supervised and programmable for 2400, 4800 and 9600 Baud. Only one printer may be connected to the port. Consult the factory for recommended printers. EIA-485 Port EIA-485 compatible port on the LED-10IM option module supports up to 32 LED-10 Remote Annunciators or 32 sets of ACM-8RF Relay Modules or 32 AFM Series Annunciators or 32 LDM Series Annunciators or any combination of the four devices totalling 32. Telephone Lines Fully supervised at all times, voltage is sensed to 4 volts and current is sensed to 5 mA. Battery Charger Battery Charger will charge up to 17 AH batteries. The MS-5210UD cabinet holds a maximum of 12 AH batteries. The Fire•Lite BB-17F is required to hold 17 AH batteries. The charger is rated for 850 mA maximum current. 1.5 Digital Communicator Two modular phone jacks allow easy connection to telephone lines. Modular jacks are labeled PH1 and PH2 for the Primary and Secondary phone lines. Telephone line 'Active' red LEDs are provided as well as a green 'Kissoff' LED. The integral digital communicator provides the following functions: • • • • Line Seizure - takes control of the phone lines disconnecting any premises phones Off/On Hook - perform on and off-hook status to the phone network Listen for dial tone - 440 hertz tone typical in most networks Dialing the Central Station(s) number - default is Touch-Tone©, programmable to rotary Document #50193 Rev. D 5/2/97 P/N 50193:D 13 Components • For tone burst or touchtone type formats: discern proper 'Ack' and 'Kissoff' tone(s) - the frequency and time duration of the tone(s) varies with the transmission format. The control panel will adjust accordingly • Communicate in the following formats: ✓ 12 Tone Burst Type: 20 pps (3+1, 4+1, 4+2, 3+1 Exp., 4+1 Exp., 4+2 Exp.) ✓ 3 Touchtone Types: 4 + 1 Ademco Express 4 + 2 Ademco Express Ademco Contact ID (Refer to Table 4-3 on page 80). 1.6 Components Main Circuit Board The main circuit board contains the system's CPU, power supply, other primary components and wiring interface connectors. Optional modules plug in and are mounted to the main circuit board. The main circuit board is delivered premounted in the cabinet. Cabinet The cabinet is red with an attractive navy blue front overlay. The backbox measures 16.900" (42.9 cm) X 14.500" (36.8 cm) X 4.625"(11.8 cm) and provides space for two batteries (up to 12 Amp Hours). Also available is an optional dress panel, DP-5210UD, which mounts inside the cabinet. Transformer Assembly FIGURE 1-4: Transformer Assemblies One 100VA transformer is provided standard with the panel. An optional 100VA transformer, XRM-24 (XRM-24E for the MS-5210UDE), is available to provide maximum accessory power. Standard Batteries The cabinet provides space for 12 Amp Hour batteries (larger batteries up to 17 Amp Hour batteries, use the listed Fire•Lite BB-17F battery box). Batteries must be ordered separately 14 Optional XRM-24(E) Document #50193 Rev.D 5/2/97 P/N 50193:D Optional Modules 1.7 Optional Modules LED-10IM The LED-10IM Interface Module provides an EIA-485 port to support the LED-10 Series Remote Annunciator, LDM Series Annunciator, AFM Series Annunciator and ACM-8RF Relay Modules. EIA-485 wiring is supervised for open circuits by this module. The LED-10IM mounts to connector J6 in the upper right corner of the main board. Refer to Figure 2-14, “LED-10IM Installation,” on page 33. ACM-8RF Relay Module The ACM-8RF option module provides eight Form-C relays rated a 5.0 amps each. The Relay Module connects to the EIA-485 port off of the LED-10IM option module. Relays are assigned to each of the 10 Initiating Device Circuits. Refer to Figure 2-17, “Wiring LED-10IM to ACM-8RF,” on page 34, for additional information. PRT-24 Printer Interface Module The Printer Interface Module may be used to connect a printer to the control panel for the purpose of printing a history report, walktest file, troubleshoot report, program entries or current system status. Printers require separate external primary power. Connect the PRT-24 module (with cable) to the serial EIA-232 port on the printer. The module mounts to the J4 connector on the main circuit board. Note that an EDP listed printer must be used if printer will be permanently attached (Refer to Figure 2-13, “Remote Printer Connections,” on page 32). The Baud rate is programmable (“Program Options” on page 38). CAC-10F Module The CAC-10F Module can be used to convert the 10 Style B (Class B) Initiating Device Circuits to 10 Style D (Class A) IDCs and the two Style Y (Class B) Notification Appliance Circuits to two Style Z (Class A) NACs. The CAC-10F module connects to J10 on the main circuit board. (Refer to Figure 2-10 on page 30). NAC-REM Module The NAC-REM (NAC/Relay) Module can be used to add two Style Z (Class A) NACs and two Form-C relays. The module connects to J7 on the main circuit board. (Refer to Figure 2-12 on page 31). 1.8 Optional Accessories Dress Panel A red dead-front dress panel (DP-5210UD) is available as an option (required for Canadian installations). The dress panel restricts access to the system wiring while allowing access to the membrane switch panel. Battery Box FIGURE 1-5: BB-17F Battery Box The Fire•Lite BB-17F battery box may be used to house two batteries greater than 12 Amp Hour to a maximum of 17 Amp Hour. The battery box mounts directly below the cabinet, centered to the main circuit board (Refer to Figure 2-2, “FACP Backbox and Battery Box,” on page 23). The BB-17F is red and is provided with knockouts. PK-5210UD Program Kit The PK-5210UD Program Kit includes three 3½" diskettes plus Instruction Manual P/N 50363. When the software is loaded into an IBM compatible computer, it creates an off-line Service Terminal that allows any MS-5210UD panel to be uploaded or downloaded over standard telephone lines. Requires panel firmware P/N: MS52102.0 or greater. Document #50193 Rev. D 5/2/97 P/N 50193:D 15 Optional Accessories LED-10 Series Annunciator (LED Zone Type Annunciator) The LED-10 Series is a 10 zone LED annunciator which mounts on a 3-gang electrical box and provides LED indication of the following: • • • • • • • Alarm Zones 1 through 10 Trouble Zones 1 through 10 AC Power (green) System Alarm (red) System Trouble (yellow) System Supervisory (yellow) Alarm Silence (yellow) FIGURE 1-6: LED-10 Series Annunciator A local trouble sounder and switches for remote Acknowledge, Silence, Drill and Reset are also provided. Wiring is inherently supervised by the FACP. Slide-in paper labels permit an easy change of zone information. DIP switches allow the enabling and disabling of the local piezo sounder (with approval of local AHJ), enabling and disabling of the mechanical keyswitch which may be used to prevent unauthorized use of the function switches and selection of annunciator receive/transmit mode (Refer to Figure 2-15 on page 33). Note that the LED-10 Series Remote Annunciator requires the use of the LED-10IM Interface Module. AFM Series Annunciators (LED Zone Type) The AFM Series Annunciators remotely display system status. The AFM/AEM-16AT annunciators display zone alarm and trouble status. In addition, they provide remote Acknowledge, Silence, Reset and Drill functions. The AFM Series Annunciators require the use of the LED-10IM Interface Module. For more detailed information, refer to the appropriate AFM Annunciator manual. 16 ✓ AFM-16ATX - The Annunciator Fixed Module-16ATX contains 16 red alarm and 16 yellow trouble LEDs, a system trouble LED, an ON LINE/POWER LED and a local piezo sounder with switches for Acknowledge, Silence, Reset and Drill. The AFM-16ATX is fixed at address '1' and will accept up to 3 AEM-16ATF Expanders. The AFM-16ATX can be mounted in a Fire•Lite ABS-1F or ABF-1F backbox. Refer to the AFM-16ATX Manual for detailed information. Note that only one AFM-16ATX is required to annunciate 10 zones of alarm and trouble, provided '8 Point Shift' function is selected. Refer to Annunciator Manual P/N 15390 for additional information. ✓ AEM-16ATF - The Annunciator Expander Module-16ATF connects to the AFM-16ATX and adds 16 sets of red alarm LEDs and yellow trouble LEDs. Up to three AEM-16ATFs may be added to an AFM-16ATX but only one is required. Note that one AEM-16ATF is required with an AFM-16ATX to annunciate 10 zones of alarm and trouble as well as general system status provided '8 Point Shift' function is not selected. Refer to Annunciator Manual P/N 15390 for additional information. Document #50193 Rev.D 5/2/97 P/N 50193:D FIGURE 1-7: AFM-16ATX Optional Accessories ✓ AFM-16ATF - The Annunciator Fixed Module-16ATF contains 16 red alarm and 16 yellow trouble LEDs, a system trouble LED, an ON LINE/POWER LED and a local piezo sounder with switches for Acknowledge, Silence, Reset and Drill. The AFM-16ATF is fixed at address '1' and communication is via the EIA-485 data line. The AFM-16ATF can be mounted in a Fire•Lite ABS-1F or ABF-1F backbox. Refer to the AFM-16AT Manual for detailed information. ✓ AFM-16AF - The Annunciator Fixed Module-16AF has 16 red alarm LEDs. Multiple annunciators may be used by setting all annunciators to Receive Only, except the last AFM-16AF in line. Each annunciator's address is internally fixed at '1' and communication is via the EIA-485 data line. The Local Silence/Acknowledge switch functions as local lamp test and silence for annunciator piezo. LEDs include On-Line and System Trouble indicators. The AFM-16AF Annunciator can be mounted in a standard 4-gang electrical box. Refer to the AFM-16AF Manual for detailed information. FIGURE 1-8: AFM-16ATF FIGURE 1-9: AFM-16AF LDM Series Lamp Driver Modules (Graphic Annunciator) The LDM Series Lamp Driver Modules, which consist of the LDM-32F master and LDM-E32F expander modules, are used to provide an interface to a custom graphic LED annunciator. The master module provides power and control for a maximum of three expander modules (expander modules are not required when interfacing to the MS-5210UD). The LDM-32F and LDM-E32F have output connectors which are used to drive lamps or LEDs and input connectors which are used for remote switch functions. The LDM Series requires the use of the LED-10IM Interface Module. Refer to the LDM Series Lamp Driver Modules Manual for a complete description. Refer to Figure 2-18, “Wiring LED-10IM to LDM-32F,” on page 35 for wiring details. ✓ LDM-32F - The Lamp Driver Module has 32 alarm lamp/LED driver outputs which sink current to system common (-) on activation. A single positive (+) voltage is required to supply total operating power for all lamps or LEDs when all drivers are activated. The LDM-32F provides a separate driver for system trouble and inputs for a local lamp test switch. A maximum of 16 external control switches may be wired to the LDM-32F. DIP switch SW3 is used to enable or disable the onboard piezo sounder, enable remote switch functions, select a flashing LED function for new alarms and troubles and other functions. Switch SW4 is used to configure the module to annunciate 32 alarms or 16 alarms and 16 troubles. A green ON-LINE LED flashes to indicate ongoing communications with the host FACP. One LDM-32F supports up to three LDM-E32F modules. The LDM-32F is supplied with four standoffs and screws for mounting to a CHS-4L chassis or custom backbox. FIGURE 1-10:LDM-32F Module FCPS-24F(E) Remote Power Supply (System Power Expansion) The FCPS-24F (FCPS-24FE for 220/240 VAC applications) is a compact, remote power supply and battery charger. This remote power supply consists of a filtered 24 VDC output that may be configured to drive up to four Notification Appliance Circuits [four Style Y (Class B) or two Style Z (Class A) and two Style Y (Class B)]. Document #50193 Rev. D 5/2/97 P/N 50193:D 17 Telephone Requirements and Warnings Alternately, the four Notification Appliance Circuits may be used as auxiliary regulated power configured for resettable or nonresettable operation. The FCPS-24F(E) may be used in a number of different applications. It may be used as a remotely mounted power supply and battery charger powering up to four, coded or noncoded, Notification Appliance Circuits. Alternately, any or all of these circuits may be used as 24 VDC output circuits capable of powering four-wire smoke detectors or any device that requires filtered power. These circuits may be configured as resettable or nonresettable outputs to expand FACP auxiliary system power. FIGURE 1-11:FCPS-24F(E) Style Y/Style Z Notification Appliance Circuit or 24 VDC Output #1 Notification Appliance Circuit Control Input #1 (from FACP) Style Y Notification Appliance Circuit or 24 VDC Output #2 Style Y/Style Z Notification Appliance Circuit or 24 VDC Output #3 Notification Appliance Circuit Control Input #2 (from FACP) Style Y Notification Appliance Circuit or 24 VDC Output #4 AC Power Battery Charger Specific Application Power FCPS Trouble Contact Output One of the most common applications for the FCPS-24F(E) remote power supply utilizes the NAC expander mode. In this application, one or two Notification Appliance Circuits (NACs) are connected from the main FACP NAC output(s) to the remote power supply Control Input circuits. When these Control Input circuits activate (due to reverse polarity of the NAC output), the power supply will activate its corresponding outputs. NAC Control Input #1 controls power supply output circuits #1 and #2. NAC Control Input #2 controls output circuits #3 and #4. During the inactive state, the remote power supply supervises its NAC field wiring for short and open circuits. If a fault is detected, the supply will enter a trouble condition and illuminate the corresponding NAC trouble LED (Output Circuits 1-4), however, once the Notification Appliance Circuits are activated, the supervision is disabled and the circuits are no longer supervised. Supervision of other power supply faults such as low battery, Earth Fault, AC loss and battery charger failure will continue and may be monitored via the independent trouble relay contact. If a specific application requires that all four outputs activate at the same time, only one NAC control input from the FACP is necessary. For this application, The Notification Appliance Circuit from the FACP is wired into NAC Control Input #1 of the remote supply and then a pair of wires are connected from NAC Control Output #1 to NAC Control Input #2. Refer to the FCPS-24F(E) Installation, Operation and Application Manual for a complete description and examples of applications. 1.9 Telephone Requirements and Warnings 1.9.1 Telephone Circuitry: Ringer Equivalence Number (REN) = 0.6B Complies with FCC Part 68 Mates with RJ31X Male Connector Supervision Threshold: less than 4.0 volts for 2 minutes The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to 18 Document #50193 Rev.D 5/2/97 P/N 50193:D Telephone Requirements and Warnings the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. 1.9.2 Digital Communicator: Before connecting the control panel to the public switched telephone network, the installation of two RJ31X jacks is necessary. The following information is provided if required by the local telephone company: Manufacturer: Fire•Lite 12 Clintonville Road Northford, CT 06472 Product Model Number: MS-5210UD FCC Registration Number: 1W6USA-74525-AL-E Ringer Equivalence: 0.6B 1.9.3 Telephone Company Rights and Warnings: The telephone company, under certain circumstances, may temporarily discontinue services and/or make changes in its facilities, services, equipment or procedures which may affect the operation of this control panel. The telephone company, however, is required to give advance notice of such changes or interruptions. If the control panel causes harm to the telephone network, the telephone company reserves the right to temporarily discontinue service. Advance notification will be provided, except in cases when advance notice is not practical. In such cases, notification will be provided as soon as possible. The opportunity will be given to correct any problems and to file a complaint. DO NOT CONNECT THIS PRODUCT TO COIN TELEPHONE, GROUND START OR PARTY LINE SERVICES. When the control panel activates, premise phones will be disconnected. Two separate phone lines are required. Do not connect both telephone interfaces to the same telephone line. The control panel must be connected to the public switched telephone network upstream of any private telephone system at the protected premises. An FCC compliant telephone cord must be used with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible RJ31X male modular plug which is Part 68 compliant. 1.9.4 For Canadian Applications The following is excerpted from CP-01 Issue 5: "NOTICE: The Canadian Department of Communication label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing the equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Document #50193 Rev. D 5/2/97 P/N 50193:D 19 Telephone Requirements and Warnings Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate." "The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100." DOC Compliance - "This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications." IC Registration Number: 21325785A Load Number: 2 20 Document #50193 Rev.D 5/2/97 P/N 50193:D Installation CHAPTER 2 2.1 Installation Mounting Options The cabinet may be either semi-flush or surface mounted. The door is removable during the installation period by opening and lifting the door off the pin hinges. The cabinet mounts using two key slots and two additional 0.250" (6.35 mm) diameter holes located in the backbox. The key slots are located at the top of the backbox and the two securing holes at the bottom. Carefully unpack the system and check for shipping damage. Mount the cabinet in a clean, dry, vibration-free area where extreme temperatures are not encountered. The area should be readily accessible with sufficient room to easily install and maintain the panel. Locate the top of the cabinet approximately five feet above the floor with the hinge mounting on the left. Determine the number of conductors required for the devices to be installed. Sufficient knockouts are provided for wiring convenience. Select the appropriate knockout(s) and pull the required conductors into the box. Note that there are no knockouts on the left (hinged) side of the cabinet. All wiring should be in accordance with the National and/or Local codes for fire alarm systems. 2.2 Backbox Mounting ✓ Open the door and lift the door off the pin hinges. ✓ Remove the main PC board assembly by unscrewing the four screws in the corners of the board. Set the board aside in a safe, clean place. Avoid static discharge which may damage the board. ✓ Mark and predrill holes for the top two keyhole mounting bolts using the dimensions illustrated in Figure 2-1. ✓ Install two upper fasteners in the wall with the screw heads protruding. ✓ Using the upper 'keyholes', mount the backbox over the two screws. ✓ Mark and drill the lower two holes. ✓ Mount backbox, install remaining fasteners and tighten. ✓ When the location is dry and free of construction dust, reinstall the main PC board. Document #50193 Rev. D 5/2/97 P/N 50193:D 21 Backbox Mounting Draw wires through the respective knockout locations. FIGURE 2-1: Cabinet Dimensions and Knockout Locations Top Left Side Right Side Bottom 22 Document #50193 Rev.D 5/2/97 P/N 50193:D Backbox Mounting FIGURE 2-2: FACP Backbox and Battery Box TR-4-R Optional BB-17F When batteries larger than 12 Amp Hour are being used, the BB-17F battery box (or equivalent) must be installed. To install the BB-17F: 1. Mount the FACP cabinet to the wall. 2. Remove knockouts on the bottom of the FACP cabinet and top of the BB-17F. 3. Using conduit, hang the BB-17F from the FACP cabinet making sure there is at least ½" of clearance between the two cabinets. 4. Anchor the BB-17F to the wall. Document #50193 Rev. D 5/2/97 P/N 50193:D 23 Operating Power 2.3 ! Operating Power WARNING: Several different sources of power can be connected to this panel. Disconnect all sources of power before servicing. The panel and associated equipment may be damaged by removing and/or inserting cards, modules or interconnecting cables while this unit is energized. Primary Power Source (AC) and Earth Ground Connections AC power connections are made inside the control panel cabinet. The primary power source for the MS-5210UD is 120 VAC, 60 Hz, 2.3 amps and for the MS-5210UDE is 220/240 VAC, 50 Hz, 1.2 amps. Run a pair of wires (with ground conductor) from the protected premises main breaker box to TB1 of the main circuit board. As per the National Electric Code, use 14 AWG (2.00 mm2, 1.6 mm O.D.) or heavier gauge wire with 600V insulation. No other equipment may be connected to this circuit. In addition, this circuit must be provided with overcurrent protection and may not contain any power disconnect devices. A separate Earth Ground connection must be made to ensure proper panel operation and lightning and transient protection. Connect the Earth Ground wire [minimum 14 AWG (2.00 mm2)] to one of the transformer mounting studs. Do not use conduit for the Earth Ground connection since this does not provide reliable protection. Secondary Power Source (Batteries) Observe polarity when connecting the battery. Connect the battery cable to J1 on the main circuit board using the plug-in connector and cable provided. The battery charger is current-limited and capable of recharging sealed lead acid type batteries. The charger shuts off when the system is in alarm. See “Battery Calculations” on page 93 for calculation of the correct battery rating. ! WARNING: Battery contains sulfuric acid which can cause severe burns to the skin and eyes and can destroy fabrics. If contact is made with sulfuric acid, immediately flush the skin or eyes with water for 15 minutes and seek immediate medical attention. FIGURE 2-3: Operating Power Connections Connect Earth Ground Wire to Transformer mounting stud 24 Document #50193 Rev.D 5/2/97 P/N 50193:D Input Circuits 2.4 Input Circuits The control panel has 10 zone input circuits. The maximum loop resistance limit for each input circuit is 100 ohms. All field wiring of each zone is supervised for opens and ground faults. Both conditions are visually and audibly annunciated as well as communicated to a central station. Each zone is a Style B (Class B) Initiating Device Circuit (IDC) designed to accept any Normally-Open contact device and conventional 2-wire, 24 volt smoke detectors. Refer to Figure 2-4, “Style B Initiating Device Circuit Connections,” on page 26, for information on wiring Style B circuits. Use the CAC-10F Option Module (Refer to Figure 2-11, “Wiring NACs and IDCs for Class A Operation,” on page 30) to convert all 10 circuits to Style D (Class A). Each zone is power-limited to 7.26 mA in standby and 42 mA in alarm. The zones may be programmed as shown below. The factory default is 2-wire smoke detector for all zones: • • • • • • • • • • • • • 2-wire Smoke Detector (factory default) Pull Station Normally-Open Contact Device(s) Supervisory Supervisory, auto-resettable Waterflow, silenceable Waterflow, nonsilenceable Reset Silence Drill Acknowledge Auto-resettable critical and noncritical process monitoring Critical and noncritical process monitoring A maximum of five waterflow devices may be used on any circuit programmed as a waterflow zone per NFPA 72. Four-wire smoke detectors may be connected to any zone. Resettable power is provided via TB2 Terminals 3 and 4. Refer to the Fire•Lite Device Compatibility Document for a list of compatible smoke detectors. It is allowable to mix an assortment of device types (i.e. smoke detectors, heat detectors, pull stations, etc.) on any zone. This is not recommended, however, since specific and detailed reports will not be possible (particularly critical when using Contact ID format). For example, the report of general fire alarm versus pull station fire alarm or smoke detector fire alarm could not be distinguished. Note that Process Monitoring refers to circuits which do not specifically tie into elements of the fire system as defined by NFPA codes. With the exception of burglary functions, process monitoring circuits could be used to monitor any nonfire functions such as water temperature, room temperature, door open/closed, gas leakage, chemical leakage, etc. Process Monitoring may be accomplished for Local, Remote and Central Station type services in the following ways: • Central and Remote Station - When a critical process is detected, the DACT will transmit the critical process alarm to the Central or Remote Station. • Local - When a critical process is detected, the relays (fail-safe) programmed to transfer will deenergize. The ACM-8RF Remote Relay Module can only be used with noncritical process monitoring. Document #50193 Rev. D 5/2/97 P/N 50193:D 25 Output Circuits FIGURE 2-4: Style B Initiating Device Circuit Connections Style B (Class B) Initiating Device Circuit (supervised and power-limited). 4.7K, ½watt, P/N: 71252 UL listed. UL listed compatible 2-wire smoke detector Manual Pull Station Heat Detector UL listed compatible 2-wire smoke detector Manual Pull Station Heat Detector Dummy Load all unused circuits (P/N: 71245) 2.5 Output Circuits DC Power Output Connections All DC power outputs are power-limited. FIGURE 2-5: Auxiliary Power Connections Nonresettable Power (500 mA) 24 VDC filtered, regulated, nonresettable power can be obtained from TB2 Terminals 1(+) and 2(-). 4-Wire Smoke Detector Power (500 mA) 24 VDC filtered, regulated, resettable power for 4-wire smoke detectors can be obtained from TB2 Terminals 3(+) and 4(-) Telephone Circuits Provision to connect to two independent telephone lines is available via two telephone jacks labeled PH1 (Primary) and PH2 (Secondary). Telephone line control/command is possible via double line seizure as well as usage of an RJ31X style interconnection. Refer to Figure 2-8, “Wiring Phone Jacks,” on page 28. Notification Appliance Circuits The MS-5210UD provides two Notification Appliance Circuits standard as Style Y (Class B). Each circuit is capable of 3.0 amps of current. Total current drawn from these as well as other DC power outputs cannot exceed 3.6 amps with the standard transformer, 6.0 amps if an optional XRM-24 Transformer (XRM-24E for the MS-5210UDE) is installed. Circuits are supervised and power-limited. Refer to the Fire•Lite Device Compatibility Document for a listing of compatible notification appliances. 26 Document #50193 Rev.D 5/2/97 P/N 50193:D Output Circuits All Notification Appliance Circuits may be programmed as follows: • • • • • • Silenceable Enabled/Disabled Auto Silence, 5 to 30 minutes Nonsilenceable Silence Inhibited March Time, Temporal or California rates. FIGURE 2-6: Notification Appliance Circuit Connections Style Y (Class B) Notification Appliance Circuit (supervised and power-limited). 4.7K ohm, ½ watt. {/N: 71252 UL listed Polarized Bell Polarized Bell Polarized Horn Polarized Horn Polarized Horn Polarized Horn Note: Notification Appliance Circuit polarity shown in alarm state. Dummy Load all unused circuits (P/N: 71245) Standard Relays The control panel provides two Form-A relays rated for 2.0 amps @ 30 VDC (resistive). Two Form-C relays can be added by installing the optional NAC-REM (NAC/Relay) module. FIGURE 2-7: Programmable Relay Terminals Relay connections may be power-limited or nonpower-limited, provided that a minimum of 0.25" is maintained between conductors of power-limited and nonpower-limited circuits. Relays automatically change to Normally Closed (energized) when programmed for activation on Trouble. Document #50193 Rev. D 5/2/97 P/N 50193:D 27 Digital Communicator 2.6 Digital Communicator Two independent telephone lines can be connected to the control panel. Telephone line control/command is made possible via double line seizure as well as usage of an RJ31X style interconnection. It is critical that the panel's digital communicator be located as the first device on the incoming telephone circuit to properly function. The control panel's digital communicator is built into the main circuit board. Connection and wiring of two phone lines is required as shown in Figure 2-8. FIGURE 2-8: Wiring Phone Jacks Primary Lines - Incoming Telco Phone Lines Tip Green Wire Tip Green Wire Ring Red Wire Ring Ring To premise phones Ring Red Wire To premise phones Tip Tip Note: Shorting bars inside RJ31X Jack removed during male plug insertion 7 foot (2.13 m) cables (MCBL-7) not supplied order separately Primary Phone Line PH1 Modular Female Connectors Secondary Phone Line PH-2 Male Plug Connectors 28 Document #50193 Secondary Lines - Incoming Telco Phone Lines Rev.D 5/2/97 P/N 50193:D UL Power-limited Wiring Requirements 2.7 UL Power-limited Wiring Requirements Power-limited and nonpower-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25" (6.35 mm) away from any nonpower-limited circuit wiring. Furthermore, all power-limited and nonpower-limited circuit wiring must enter and exit the cabinet through different knockouts and/or conduits. A typical wiring diagram for the MS-5210UD is illustrated in Figure 2-9. FIGURE 2-9: Typical Wiring Diagram for UL Power-limited Requirements Power-limited Circuit Note that power-limited wiring is connected to terminal block below the installed circuit board Nonpower-limited Circuits Power-limited Circuits Power-limited Circuit AC Power 2.8 Installation of Optional Modules CAC-10F Class A Converter Module The CAC-10F Module can be used to convert the 10 Style B (Class B) Initiating Device Circuits to 10 Style D (Class A) IDCs and the two Style Y (Class B) Notification Appliance Circuits to two Style Z (Class A) NACs. J1 Document #50193 Rev. D 5/2/97 P/N 50193:D 29 Installation of Optional Modules of the module plugs into connector J10 of the MS-5210UD, which is located at the top center of the FACP main circuit board. Install the two supplied metal standoffs in the holes on the main circuit board (refer to Figure 2-10). Carefully align the two connectors and press the CAC-10F module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any pins. Secure the CAC-10F module to the standoffs using the two supplied screws. It is important that the supplied screw and washer be used to secure the module to the metal standoff. This is necessary in order to help protect against electrical transients. FIGURE 2-10:Installation of CAC-10F Module metal standoff J1 - on back of module metal standoff Wire the Style Z (Class A) Notification Appliance Circuits (NACs) using TB4 of the MS-5210UD and TB1 of the CAC-10F module. Wire the Style D (Class A) Initiating Device Circuits (IDCs) using TB5 of the MS-5210UD and TB2 of the CAC-10F module. Make certain to observe polarity when connecting the devices to the circuits. The B+ and A+ terminals must comprise the feed and return for the positive side of a device and the B- and A- terminals must comprise the feed and return for the negative side of a device. To configure any of the zones for Class B when the CAC-10F is installed, simply wire to the B+ and B- inputs on TB5 of the main circuit board and install the EOL resistor across the end of the circuit. Do not wire to the corresponding A+ and A- terminals on TB2 of the CAC-10F module. Refer to Figure 2-10 and Figure 2-11. FIGURE 2-11:Wiring NACs and IDCs for Class A Operation All unused terminals must be jumpered. Jumper A+ to B+ and A- to B-. NAC-REM (NAC/Relay Expander Module) The NAC-REM Module can be used to add two Style Y (Class B) or Style Z (Class A) NACs (1.5 amps maximum each) and two Form-C relays to the MS-5210UD. Connector J1 of the NAC-REM module plugs into connector J7 which is located at the top left corner of the MS-5210UD main circuit board. 30 Document #50193 Rev.D 5/2/97 P/N 50193:D Installation of Optional Modules Install the two supplied metal standoffs into the FACP main circuit board. Ensure that the metal standoff is installed in the position indicated in Figure 2-12. Carefully align the two connectors and press the NAC-REM module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any pins. It is important that the supplied screw and washer be used to secure the module to the metal standoff. This is necessary in order to help protect against electrical transients. FIGURE 2-12:Installation and Wiring of NAC-REM Module NAC #4 Style Y (Class B) supervised and power-limited. 4.7K ohm, ½ watt Part #71252 UL listed. NAC #3 Style Z (Class A) supervised and power-limited. Metal Standoff PRT-24 Printer Interface Module A remote printer may be permanently or temporarily connected to provide a hardcopy printout of normal current system status and activity, program entries, history file, troubleshoot mode voltages and walktest data. The PRT-24 provides an EIA-232 conversion to adapt to most 40 and 80 column printers. ! CAUTION: DO NOT connect a printer to the Fire Alarm Control Communicator if a ground fault exists on the panel. Circuit damage may result. Installation - Remote printers require a separate external primary power source. Also required is the PRT-24 which includes the Printer Interface Module and a 6-foot (1.83 m) interface cable prewired to a DB25 connector. Connect the interface cable to the PRT-24 as illustrated in Figure 2-13. Insert the two supplied standoffs into mounting holes near the J4 connector on the main circuit board. Connect the Printer Interface board to J4 on the main circuit board, press onto standoffs and connect the attached cable to the serial EIA-232 port on the printer. The printer may be placed a maximum of 50 feet (15.24 m) from the panel. Note that a ground fault may occur on the control panel when this connection is made. For this reason, it is important that there be no preexisting ground fault on the panel. For permanent printer connection, a ground fault is not allowed. Document #50193 Rev. D 5/2/97 P/N 50193:D 31 Installation of Optional Modules Printer Configuration - The PRT-24 is required. Also refer to the documentation supplied with your printer. Set the printer's options as listed in Table 2-1 . Baud rate is programmable to 2400, 4800 or 9600. TABLE 2-1: Printer Settings Typical Printer Under the MENU area: COMMUNIC. SETUP: DATA BITS: 7 PARITY: EVEN STOP BIT: 1 STOP BAUD RATE: MUST MATCH FACP SETTING FIGURE 2-13:Remote Printer Connections J1 located on back of PRT-24 board DB-25P Front View PRT-24 connection to main board LED-10IM - EIA-485 Interface Module The LED-10IM Interface Module provides an EIA-485 port to support the LED-10 Series Remote Annunciator, LDM Series Annunciator, AFM Series Annunciator and the ACM-8RF Relay Module. EIA-485 wiring is supervised for open circuits by this module. The LED-10IM mounts to connector J6 in the upper right corner of the main board. Install the two supplied standoffs into the FACP main circuit board. Ensure that the metal standoff is installed in the position indicated in Figure 2-14. Carefully align the two connectors and press the LED-10IM module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any pins. It is 32 Document #50193 Rev.D 5/2/97 P/N 50193:D Installation of Optional Modules important that the supplied screw and washer be used to secure the module to the metal standoff. This is necessary in order to help protect against electrical transients. FIGURE 2-14:LED-10IM Installation metal standoff LED-10 Series Remote LED Annunciator The LED-10 Series Annunciator connects to the MS-5210UD via the LED-10IM Interface Module. It is recommended that overall foil/braided-shielded, twisted pair cable with a maximum length of 6,000 feet (1,800 m) @ 18 AWG (0.75 mm2) be used. Regulated power can be supplied by the MS-5210UD or a remote UL listed filtered, regulated power supply such as the Fire•Lite FCPS-24. FIGURE 2-15:Wiring LED-10IM to LED-10 Series Top View LED-10 Series Annunciator LED-10 Series Annunciator - + EIA-485 Earth Ground - 24 VDC + 24 VDC +24 VDC Earth Ground Shield LED-10IM -24 VDC Document #50193 Rev. D 5/2/97 P/N 50193:D 33 Installation of Optional Modules ACM-8RF Remote Relay Module FIGURE 2-16:ABS-8R Enclosure The ACM-8RF Module provides eight Form-C relays with contacts rated for 5.0 amps. Relays can be assigned to each of the ten Initiating Device Circuits (two ACM-8RF relay modules are required). The module is installed on the EIA-485 line using the LED-10IM Interface Module. Communication wiring is supervised by the FACP. Power for the module must be power-limited. Refer to the ACM-8RF Manual for UL power-limited wiring requirements and switch SW4 receive/transmit selection option. Removable terminal blocks are provided for ease of installation and servicing. DIP switch SW3 allows assignment of relays to FACP IDCs. The ACM-8RF module can be mounted remotely in an ABS-8RF annunciator surface-mount backbox. ACM-8RF Address and SW3 DIP Switch Settings - Each of the ten MS-5210UD IDCs can be assigned to an ACM-8RF relay. Two relay modules are required, with both set to the same address. Use the decade rotary switches to set the address (i.e. for address '01', position the first [left] switch so the arrow points to '0' and the second [right] switch so the arrow points to '1'). “Level Three - Option Module Selections” on page 62, Annunciator Maximum Monitored Address (02-03). ✓ To assign the first eight relays of the first ACM-8RF Relay Module to FACP IDCs 1 through 8, set ACM-8RF SW3 DIP switches 2 and 5 ON and 1, 3, 4, 6, 7 and 8 OFF. ✓ To assign the first two relays of the second ACM-8RF Relay Module to FACP IDCs 9 and 10, set ACM-8RF SW3 DIP switches 3 and 5 ON and 1, 2, 4, 6, 7 and 8 OFF. FIGURE 2-17:Wiring LED-10IM to ACM-8RF ACM-8RF NO C NC To Next Device IN (-) OUT (+) OUT (+) IN (+) SYS COM SYS COM 24 VDC 24 VDC EARTH Left Decade Switch Power-limited 24 VDC LED-10IM 34 Document #50193 Rev.D 5/2/97 P/N 50193:D Right Decade Switch Installation of Optional Modules LDM-32F Lamp Driver Module The Lamp Driver Module is used to provide an interface to a custom graphic annunciator. The LDM-32F has 32 alarm lamp/LED driver outputs which sink current to system common (-) on activation. A single positive (+) voltage is required to supply total operating power for all lamps or LEDs when all drivers are activated. The LDM-32F provides a separate driver for system trouble and inputs for a local lamp test switch. A maximum of 16 external control switches may be wired to the LDM-32F. DIP switch SW3 is used to enable or disable the onboard piezo sounder, enable remote switch functions, select a flashing LED function for new alarms and troubles and other functions. A green ON LINE LED flashes to indicate ongoing communications with the host FACP. The LDM-32F is supplied with four standoffs and screws for mounting to a CHS-4L chassis or custom backbox. The LDM-32F is installed on the EIA-485 line using the LED-10IM Interface Module. Communications wiring is supervised by the FACP. Power for the module must be power-limited. LDM-32F Switch Settings - Use the decade rotary switches to set the address (i.e. for address '02', position switch SW1 [top] so the arrow points to '2' and switch SW2 [bottom] so the arrow points to '0'). FIGURE 2-18:Wiring LED-10IM to LDM-32F To Next Device + EIA-485 + Power-limited 24 VDC Source LDM-32F LED-10IM Document #50193 Rev. D 5/2/97 P/N 50193:D 35 Installation of Optional Modules AFM-16ATX and AFM-16ATF Annunciators The Annunciator Fixed Modules-16ATX and 16ATF each contain 16 red alarm and 16 yellow trouble LEDs, a system trouble LED, an ON LINE/POWER LED and a local piezo sounder with switches for FACP Acknowledge, Silence, Reset and Drill. The AFM-16ATX is fixed at address '1' and is installed on the EIA-485 line using the LED-10IM Interface Module. AFM-16AF Annunciator The Annunciator Fixed Module-16AF has 16 red alarm LEDs. The annunciator address is fixed at '1' and communication is via the EIA-485 line using the LED-10IM Interface Module. The Local Silence/Acknowledge switch functions as a local lamp test and silence for the annunciator piezo sounder. LEDs include ON LINE/POWER and System Trouble. FIGURE 2-19:Wiring LED-10IM to AFM-16ATX To Next Device EIA-485 + + Power-limited 24 VDC Source LED-10IM 36 Document #50193 Rev.D 5/2/97 P/N 50193:D Programming Instructions CHAPTER 3 Programming Instructions This section describes programming the panel from the onboard keyboard or the remote site upload/download software which allows programming the control panel off premises. Programming of the control panel is possible at any time except when an alarm condition is present or during a fire drill. The control panel has been designed for many different types of applications. After examining your specific application, review the programming options and choose the entries best suited for your system. The control panel has a built-in intelligent programmer. All programming selections are stored in nonvolatile Electrically-Erasable Programmable Read-Only Memory (EEPROM). This ensures that the control panel will remember all entries made in programming mode even if both AC and battery power are removed. Invalid entries cause a 'beep' from the onboard piezo sounder. The user must program the primary and secondary phone numbers, account numbers and 24 hour test report times for each central station account and the current time and date. The control panel comes with factory chosen options/features already programmed. Other options/features may be programmed if desired. If all factory default settings are acceptable, programming is complete. Successful entry into Program Mode from the keypad shuts off the fire protection and places the panel into trouble. A 'system off normal' message is transmitted to the central station. Programming via the PK-5210UD upload/download software is accomplished with the fire protection active/on. 3.1 Entering Program Mode Program Mode is divided into four levels: 1. Main Panel Options 2. Event Codes/Transmission Formats 3. Option Module Selections 4. Upload/Download Each level of Program Mode is entered by pressing the MODE key and then keying in the program mode entry code (7764) and pressing the [ENTER/STORE] key. ☛ 7764 spells PROG on a Touch-Tone phone® If an incorrect key is entered, reenter the proper 4-digit code before pressing the [ENTER/STORE] key. Note that as information is entered into the control panel, the digits will scroll across the display from right to left: ---7 --77 -776 7764 You are allowed a pause of up to 10 seconds in between each number while entering the code. After pressing the [ENTER/STORE] key, the control panel will be in Program Mode and will display P--1, with the 1 flashing. If the [ENTER/STORE] key is pressed, Level 1 (Main Panel Options) will be selected for programming. If Level 2 (Event Codes/Transmission Formats), Level 3 (Option Module Selections) or Level 4 (Upload/Download) is keyed in and then the [ENTER/STORE] key pressed, the corresponding Level will be selected for programming. You are allowed up to ten minutes of idle time at this point before starting your programming, otherwise, the control panel will return Document #50193 Rev. D 5/2/97 P/N 50193:D 37 Switch Functions to Normal Mode. You also have a maximum of 10 minutes between any key stroke. All entries made prior to the 10 minute time-out are valid and are stored. Once in any of the four levels of the Programming Mode, the control panel will: • • • • • • • Blink the Trouble LED Activate the trouble relay Disable the Notification Appliance Circuit(s) Disable the alarm relay Display 00_F Ignore all other keys other than those mentioned in this section Continue to communicate any events not previously acknowledged at a central station prior to entering Programming Mode While in any of the four levels of Programming Mode, the first three locations on the left of the display represent the memory address and the last location (farthest right) represents the contents of the memory address. The first address displayed is shown below: 00_F (address)(data) 3.2 Switch Functions The function of each switch in program mode is illustrated below: FIGURE 3-1: Control Panel Keypad No function in Program Mode - Select operating mode - Increment memory address Address entry keys are 0 to 9 - Decrement memory address Once = First memory address Twice = Type any address - Save data, go to next address Data entry keys are 0 to 9 and A to F 3.3 Program Options 3.3.1 Level 1 - Main Panel Options Note that the factory default setting for Location 56 is '0' for Control Panel only. This keeps the communicator off until location 56 is changed to ‘1’ for panel/communicator. Once location 56 is set to ‘1’ and a valid phone number is entered, entry into the program mode will cause transmission of the 'System Off Normal' report. Primary Central Station Phone Number (00-15) The first sixteen addresses, 00-15, are factory set to 'F' (from 00_F to 15_F). Programming is typically done as follows: 38 ✓ If your phone number is 484-7161, press 4. ✓ The display will read 00_4. Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options ✓ Press [ENTER/STORE] to save the entry to memory and increment to the next address 01_F. ✓ Enter the remaining numbers in their respective addresses as shown below: Entry Address 4 8 4 7 1 6 1 F F F F F F F F F 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Valid entries for both the primary and secondary phone numbers are 0 to 9 and A to F with the numeric digits as dialed numbers and the hexadecimal digits representing the following functions: • • • • • • A = * on a Touch-Tone phone keypad B = # on a Touch-Tone phone keypad C = look for secondary dial tone for up to two seconds (then dial anyway) D = three second pause E = five second pause F = end of phone number (Note: F must be entered in all unused phone number locations) Primary Central Station Number Communication Format (16) One location is needed to select the Communication Format to the primary phone number. Address 16 is used for this purpose. The default ( factory setting) for this address is 'E', which is Contact ID Format. You may enter '0' through 'D' in place of the default, then press [ENTER/STORE]. Choose from the list of formats below: 0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK 1: 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK 2: 3+1 Standard 1800 Hz Carrier, 2300 Hz ACK 3: 3+1 Expanded 1800 Hz Carrier, 2300 Hz ACK 4: 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK 5: 3+1 Expanded 1900 Hz Carrier, 1400 Hz ACK 6: 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK 7: 4+1 Expanded 1800 Hz Carrier, 2300 Hz ACK 8: 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK 9: 4+1 Expanded 1900 Hz Carrier, 1400 Hz ACK A: 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK B: 4+2 Expanded 1800 Hz Carrier, 2300 Hz ACK C: 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK D: 4+2 Expanded 1900 Hz Carrier, 1400 Hz ACK E: Contact ID, DTMF, 1400/2300 ACK F: Future use Note: Consult you Central Station for proper selection or consult our factory representatives. For any format chosen, the control panel automatically programs all of the event codes. See Table 3-3 through Table 3-8 . ! CAUTION: Default entries for event codes (as shown in Table 3-3 through Table 3-8 ) are programmed into memory each time address '16' is altered. Be certain to double check entries after programming the zone functions, addresses 64 - 73. Program the format first, then program the zone(s) function. Do not alter while the communicator is active. Primary Central Station Number Account Code (17-20) The four locations at addresses 17-20 default to all '0s'. Valid entries are 0-9 and A-F. The number of digits entered must match the format selection. If programming '2, 3, 4 or 5' into address 16, enter three digits (one digit each in locations 17, 18 and 19 - location 20 is ignored). If programming '0, 1, 6, 7, 8, 9, A, B, C, D or E' into address 16, enter four digits (one digit each in locations 17, 18, 19 and 20). Document #50193 Rev. D 5/2/97 P/N 50193:D 39 Program Options Primary Central Station Number 24 Hour Test Time (21-24) Use military time when entering the 24 hour 'test' time. The 24 hour test report to phone number 1 takes up four locations, from addresses 21-24. The default is 00:00 (12:00 midnight). The limits for each location are as follows (do not use values of A-F as entries): 21: enter 0, 1 or 2 22: enter 0-9 23: enter 0-5 24: enter 0-9 Primary Central Station Number 24/12/8/6 Hour Test Time Interval (25) The test report sent to the Primary phone number may be sent every 6, 8, 12 or 24 hours. If the message is to be sent every 24 hours, leave the factory default entry of ‘0’. If other test report times are needed, enter 1=12hr, 2=8hr or 3=6hr. Secondary Central Station Phone Number (26-41) Programming is similar to programming the primary phone number located at addresses 00 - 15. The defaults are also all 'Fs'. Entry Address F F F F F F F F F F F F F F F F 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Secondary Central Station Number Communication Format (42) Programming is the same as the primary number's Communication Format at address 16. Default entry is 'E', Contact ID Format. Choose one entry from the list below: 0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK 1: 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK 2:3+1 Standard 1800 Hz Carrier, 2300 Hz ACK 3: 3+1 Expanded 1800 Hz Carrier, 2300 Hz ACK 4: 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK 5: 3+1 Expanded 1900 Hz Carrier, 1400 Hz ACK 6: 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK 7: 4+1 Expanded 1800 Hz Carrier, 2300 Hz ACK 8: 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK 9: 4+1 Expanded 1900 Hz Carrier, 1400 Hz ACK A: 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK B: 4+2 Expanded 1800 Hz Carrier, 2300 Hz ACK C: 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK D: 4+2 Expanded 1900 Hz Carrier, 1400 Hz ACK E: Contact ID, DTMF, 1400/2300 ACK F: Future use Note: Consult your Central Station for proper selection or consult our factory representatives. For any format chosen, the control panel automatically programs all of the event codes. See Table 3-3 through Table 3-8 . ! 40 CAUTION: Default entries for event codes (as shown in Table 3-3 through Table 3-8 ) are programmed into memory each time address '42' is altered. Be certain to double check entries after programming the zone functions, addresses 64 - 73. Program the format first, then program the zone(s) function. Do not alter entry while the communicator is active. Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options Secondary Central Station Number Account Code (43-46) Four locations at addresses 43-46 default to all '0s'. Valid entries are 0-9 and A-F. The number of digits entered must match the format selection. If programming '2, 3, 4 or 5' into address 42, enter three digits (one digit each in locations 43, 44 and 45 - location 46 is ignored). If programming '0, 1, 6, 7, 8, 9, A, B, C, D or E' into address 42, enter four digits (one digit each in locations 43, 44, 45 and 46). Secondary Central Station Number 24-Hour Test Time (47-50) Use military time when entering the 24 hour 'test' time. The 24 hour test report to phone number 2 takes up four locations, from addresses 47-50. The default is 00:00 (12:00 midnight). The limits for each location are as follows (do not use values of A-F as entries): 47: enter 0, 1 or 2 48: enter 0-9 49: enter 0-5 50: enter 0-9 Secondary Central Station Number 24/12/8/6 Hour Test Time (51) The test message sent to the Secondary phone number may be sent every 6, 8, 12 or 24 hours. If the message is to be sent every 24 hours, leave the factory default entry of '0'. If other test report times are needed, enter 1=12hr, 2=8hr or 3=6hr. Alarm Presignal (52) Alarm Presignal is used to delay Notification Appliance Circuit(s) activation while allowing for visual verification by a person. Once a zone triggers an alarm, the mainboard piezo sounder and the annunciator piezo sounder turn on steady, the alarm LEDs on the FACP and annunciator flash, the FACP display indicates the activated zone, the annunciator zone LED flashes and the Notification Appliance Circuits are held off for 15 seconds. During this time, if the Silence or Acknowledge switch is pressed, the piezos are silenced and the notification appliances may be held off for up to three minutes. (See Alarm Presignal Delay Timer Address 53-55). After the programmed delay period, the notification appliances will activate if the source of the alarm is not cleared. Presignal does not function for zones defined as Waterflow, Supervisory, Process Monitoring or zones defined as Remote Switches. Factory default is '0' for no alarm presignal. Enter '1' to select alarm presignal. During alarm presignal, access to other modes is prevented and the communicator will not transmit a signal to the central station signifying that the alarm presignal sequence has been initiated. ! CAUTION: ACM-8RF relays will activate during the Alarm Presignal sequence. Alarm Presignal Delay Timer (53-55) The Alarm Presignal Timer is factory set to 120 seconds (2 minutes), with addresses 53=1, 54=2 and 55=0. The timer may be programmed from 0 to 179 seconds. Location 52 must be set to '1'. Communicator/Fire Panel Selection (56) Leaving address 56 at '0' causes the control panel to operate as a fire panel only. Selecting '1' will make it operate as a fire panel/communicator. Backup Reporting (57) Leaving address 57 at '0' means that reports will be transmitted to the secondary Central Station phone number only if attempts to communicate to the primary Central Station phone number are unsuccessful. Programming a '1' causes all reports to be transmitted to both the primary and secondary Central Station phone numbers. Programming a '2' causes reports to go to the first available receiver. ! CAUTION: Do not alter this entry while the communicator is active. Touchtone/Rotary Select for Primary Phone (58) A '0' programmed in this address by the factory triggers Touchtone dialing over the primary phone line. Select '1' for rotary dialing. Document #50193 Rev. D 5/2/97 P/N 50193:D 41 Program Options Make/Break Ratio for Primary Phone (59) Use this address only if you have chosen '1' for address 58. The Make/Break ratio is factory set to '0' which is 67/ 33 ratio, but may be changed to '1' which is 62/38 ratio. Touchtone/Rotary Select for Secondary Phone (60) A '0' programmed in this address by the factory triggers Touchtone dialing over the secondary phone line. Select '1' for rotary dialing. Make/Break Ratio for Secondary Phone (61) Use this address only if you have chosen '1' for address 60. The Make/Break ratio is factory set to '0' which is 67/ 33 ratio, but may be changed to '1' which is a 62/38 ratio. Address (62) Leave entry as default of '0'. Address (63) Leave entry as default of '0'. Zones 1 through 10 Function Selection (64-73) The ten zones on the control panel may be programmed as shown in Table 3-1 . Program entries alter zone function, transmittal priority and, as a result of altering the zone definition, the transmitted event code message is automatically changed. Remote switch entries 9, A, B and C cause the zone function to be altered to match the FACP keypad entries. Initial closure (or shorting) of a switch causes the switch function to occur. The switch must be returned to its normal position. TABLE 3-1: Zone Functions Program Entry Function 0 Operate 2-wire smoke detectors 1 Pull Station 2 Normally-Open Contact Device (heat detector, 4-wire smoke, etc.) 3 Supervisory 4 Supervisory, autoresettable. Self restore function, is not latched by the control panel 5 Waterflow, silenceable. Silencing of Silenceable Notification Appliance Circuits allowed 6 Waterflow, nonsilenceable. Silencing of Silenceable Notification Appliance Circuits not allowed. Must clear waterflow alarm condition and press reset key 7 Critical and noncritical process monitoring 8 Autoresettable process monitoring 9 Remote reset switch1 A Remote silence switch1 B Remote acknowledge switch1 C Remote manual evacuate (drill) switch1 1. For remote switch applications, use Fire•Lite P/N: AKS-1F or equivalent UL listed switch. Zone 1 Function Selection (64) Factory default for zone 1 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. 42 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options Zone 2 Function Selection (65) Factory default for zone 2 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 3 Function Selection (66) Factory default for zone 3 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 4 Function Selection (67) Factory default for zone 4 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 5 Function Selection (68) Factory default for zone 5 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 6 Function Selection (69) Factory default for zone 6 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 7 Function Selection (70) Factory default for zone 7 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 8 Function Selection (71) Factory default for zone 8 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Zone 9 Function Selection (72) Factory default for zone 9 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Document #50193 Rev. D 5/2/97 P/N 50193:D 43 Program Options Zone 10 Function Selection (73) Factory default for zone 10 is '0' for 2-wire smoke detector. Enter '1' for Pull Station; '2' for Normally-Open contact device; '3' for Supervisory; '4' for Supervisory, autoresettable; '5' for Waterflow, silenceable; '6' for Waterflow, nonsilenceable; '7' for critical and noncritical process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; or 'C' for remote manual evacuate (drill) switch. Note: Programming any zone to function as supervisory or supervisory autoresettable will cause the defaulted zone alarm event codes (see note in Table 3-2 ) to be automatically changed. The defaulted code of '1' is changed to '8' for formats 3+1 and 4+1 Standard and Expanded, 4+2 Expanded and 4+1 Express (refer to Table 3-3 and Table 3-6 ). The defaulted codes of 11 through 1A are changed to 81 through 8A accordingly for formats 4+2 Standard and 4+2 Express (refer to Table 3-4 and Table 3-7 ). Programming any zone to function as process monitoring (Zone Function Selections 7 or 8) will cause the alarm event code to be automatically programmed as '0' or '00' which disables the report. Be certain to reprogram the alarm event code for each process monitoring zone. Restoral codes remain unchanged from factory defaults. When using Contact ID Format, zone alarm and zone restoral event codes change automatically as shown in Table 3-2 . Be certain to reprogram alarm event codes when selecting process monitoring functions. Zone fault and disable event codes may also be user programmed (refer to “Ademco Contact ID Format Event Code Descriptions” on page 111). Programming a zone as a remote switch causes no transmission of an alarm or alarm restoral event code. The zone wiring continues to be supervised for opens whereas a short simulates closure of a reset, silence, drill or acknowledge switch. Zone fault and zone restoral codes continue to be transmitted. TABLE 3-2: Event Code Changes for ID Contact Format Zone Function Selection Function Zone Alarm/Restoral Event Code 0 2-wire Smoke 111 1 Pull Station 115 2 N.O. Contact Device 110 3 Supervisory 200 4 Autoresettable Supervisory 200 5 Waterflow (silenceable) 113 6 Waterflow (nonsilenceable) 113 7 Process Monitoring 0001 8 Autoresettable Process Monitoring 0001 9 Reset Switch N/A A Silence Switch N/A B Acknowledge Switch N/A C Drill Switch N/A 1. Be certain to program appropriate process monitoring functions (refer to “Ademco Contact ID Format Event Code Descriptions” on page 111). Waterflow Retard Timer (74-75) A delay may be added prior to declaring a Waterflow type of alarm. Delays up to 89 seconds are allowed. The default for addresses 74 and 75 are '00' (no additional delay). Valid entries for 74 are 0 through 8 and for 75 are 0 through 9. Program an entry into these addresses only if entering a '5' or '6' in any of the addresses 64 through 73. Be careful to include any built-in delays of the waterflow device. Alarm Verification (76) Alarm verification works only on zones programmed as 2-wire smoke detector zones. After detecting an alarm, the panel removes power from all zones for six seconds, resetting all 2-wire smoke detectors. Power is reapplied 44 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options and a 12 second retard period allows detectors to stabilize. During the retard/reset period of 18 seconds, subsequent alarms by the same initiating zone are ignored. An alarm detected on any other 2-wire detector zone during the retard period will cause immediate verified alarms. A subsequent alarm on the initiating zone occurring within the confirmation time will cause a verified alarm. ! CAUTION: Mixing devices on zones designated as 2-wire smoke zones is not recommended. The communicator will not transmit a signal to the central station signifying that alarm verification is in progress. Note that during the alarm verification period, access to other modes of operation is prevented. FIGURE 3-2: Verification Timing Diagram 0 Sec. Detector Alarm Verification ALARM VERIFICATION PERIOD 18 Sec. 6 Sec. RETARD RESET 120 Sec. CONFIRMATION TIME Detector Zone goes into Alarm Alarm Ignored Control Panel Processes Alarm if Same Detector Zone is Still in Alarm 0 Different Detector Zone Alarms 30 60 90 120 Control Panel Immediately Processes Alarm Factory default selection is no verification which is '0'. Entering a '1' enables verification. Consult the Local Authority Having Jurisdiction (LAHJ) prior to altering this address. AC Loss Reporting Delay (77) Enter a digit of 0 - 9 or A - F corresponding to the number of hours to be delayed in reporting the loss of AC power. Factory default is 6 hour delay. The valid entries are '0' = 6 hours, '1' = 7 hours, '2' = 8 hours, '3' = 9 hours, '4' = 10 hours, '5' = 11 hours, '6' = 12 hours, '7' = 15 hours, '8' = 16 hours, '9' = 17 hours, 'A' = 18 hours, 'B' = 19 hours, 'C' = 20 hours, 'D' = 21 hours, 'E' = 22 hours, 'F' = 23 hours. Programmable Relay #1 (78) Relay #1 on TB3 of the MS-5210UD main circuit board can be programmed to activate for any one of seven FACP conditions. The factory default for address 78 is '0' for activation on alarm. Program a '1' for supervisory, '2' for supervisory autoresettable, '3' for trouble, '4' for communication fail, '5' for process monitoring or '6' for process monitoring autoresettable. Programmable Relay #2 (79) Relay #2 on TB3 of the MS-5210UD main circuit board can be programmed to activate for any one of seven FACP conditions. The factory default for address 79 is '3' for activation on trouble. Program a '0' for alarm, '1' for supervisory, '2' for supervisory autoresettable, '4' for communication fail, '5' for process monitoring or '6' for process monitoring autoresettable. Notification Appliance Circuit #1 Enable (80) Notification Appliance Circuit #1 may be programmed as '0' for silenceable, '1' for nonsilenceable or '2' for disabled. Factory default is '0' for silenceable. Note: Consult the Local Authority Having Jurisdiction (LAHJ) prior to altering this address. Silence Inhibit Notification Appliance Circuit #1 (81) Setting address 81 to '1' prohibits silencing of Notification Appliance Circuit #1 for one minute after initiation of an alarm. Factory default is '0' for no silence inhibit of Notification Appliance Circuit #1. Autosilence Notification Appliance Circuit #1 (82) Notification Appliance Circuit #1 may be autosilenced after a programmed time interval between 5 and 30 minutes. Enter '1' for 5 minute autosilence; '2' for 10 minute autosilence; '3' for 15 minute autosilence; '4' for 20 minute autosilence; '5' for 25 minute autosilence; or '6' for 30 minute autosilence. The factory default is '0' for no autosilence. Document #50193 Rev. D 5/2/97 P/N 50193:D 45 Program Options Coding of Notification Appliance Circuit #1 (83) Coding of Notification Appliance Circuit #1 is selectable for the following: '1' for March Time (120ppm); '2' for California (10 seconds On, 5 seconds Off); or '3' for Temporal (½ second On, ½ second Off, ½ second On, ½ second Off, ½ second On, 1½ seconds Off and then repeat). Factory default is '0' for steady (no coding). Notification Appliance Circuit #2 Enable (84) Notification Appliance Circuit #2 may be programmed as '0' for silenceable, '1' for nonsilenceable or '2' for disabled. Factory default is '0' for silenceable. Note: Consult the Local Authority Having Jurisdiction (LAHJ) prior to altering this address. Silence Inhibit Notification Appliance Circuit #2 (85) Setting address 85 to '1' prohibits silencing of Notification Appliance Circuit #2 for one minute after initiation of an alarm. Factory default is '0' for no silence inhibit of Notification Appliance Circuit #2. Autosilence Notification Appliance Circuit #2 (86) Notification Appliance Circuit #2 may be autosilenced after a programmed time interval between 5 and 30 minutes. Enter '1' for 5 minute autosilence; '2' for 10 minute autosilence; '3' for 15 minute autosilence; '4' for 20 minute autosilence; '5' for 25 minute autosilence; or '6' for 30 minute autosilence. The factory default is '0' for no autosilence. Coding of Notification Appliance Circuit #2 (87) Coding of Notification Appliance Circuit #2 is selectable for the following: '1' for March Time (120ppm); '2' for California (10 seconds On, 5 seconds Off); or '3' for Temporal (½ second On, ½ second Off, ½ second On, ½ second Off, ½ second On, 1½ seconds Off and then repeat). Factory default is '0' for steady (no coding). Trouble Reminder (88) Factory default '0' disables the trouble reminder feature. Selecting '1' will cause a reminding beep (after the Silence or Acknowledge switch is pressed) every 15 seconds during an alarm and beep every two minutes during a trouble condition. The beeps from the onboard piezo sounder will occur until the alarm or fault is cleared. Programming the Real-Time Clock and Calendar (89-999) Entering an address greater than 88 will cause a display of the current time. On initial power-up, the clock will start running from the factory setting of 00:01 (military time). The far left digit will be flashing, indicating that this is the first digit to be programmed. Note that the software for the MS-5210UD operates the internal clock based upon 60 Hz. The software for the MS-5210UDE operates the internal clock based upon 50 Hz. • Programming Hours and Minutes - To program the first hour digit, press the corresponding number on the keypad and then press [ENTER/STORE]. For example, to program 08:00 AM, press '0' on the keypad and then [ENTER/STORE]. The digit 2nd from the left will start flashing. Enter the second hour digit and press [ENTER/STORE]. In the previous example, the number '8' would be pressed on the keypad followed by the [ENTER/STORE] key. This completes the Hours setting. The digit 2nd from the right should now be flashing on the display. Select the first digit for the minutes by pressing the corresponding number on the keypad and then the [ENTER/STORE] key. The digit on the far right of the display will now be flashing. Select the second digit for the minutes by pressing the corresponding number on the keypad and then the [ENTER/ STORE] key. The Minutes setting is now complete. If during programming of the time an invalid digit is selected (i.e. 3 or higher for the first digit) the FACP piezo sounder will beep and the digit will continue to blink until a valid entry is made. • Programming Year - After entering the last digit corresponding to minutes (far right digit), the display will read 1996 with the digit '9', second from the right, flashing. Press [ENTER/STORE] if acceptable. To change the year, enter a digit. Entering a zero '0' will change the display to the year 2000. Press the [ENTER/ STORE] key. Repeat for the digit to the far right. 46 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options • Programming Month/Day - After the year is entered, the display will show four digits representing the month and day of the software release date. The month is represented by the two digits on the left and the day by the two digits on the right. The digit on the far left will be flashing. The month and day are set the same way as the hours and minutes. Once the last digit corresponding to the day is entered, the display will show the contents of address '00'. The real time clock/calendar keeps track of leap years automatically. End Programming/Exit to Alternate Program Level Exit Programming Mode by pressing MODE, followed by the 4-digit code corresponding to an alternate mode of operation, then press [ENTER/STORE]. To enter a different Programming Level, press MODE and then press the [ENTER/STORE] key. The display will show P__1 with the '1' flashing. Press the digit (2, 3 or 4) of the Programming Level to be accessed. During Program Mode, if no key is pressed within 10 minutes, the panel will revert to Normal Mode. 3.3.2 Level Two - Event Codes/Transmission Formats Each option of the Program Mode is entered by keying in the program mode entry code (7764) and pressing the [ENTER/STORE] key. ☛ 7764 spells PROG on a Touch-Tone® phone If an incorrect key is entered, reenter the proper 4-digit code before pressing the [ENTER/STORE] key. Your are allowed a pause of up to 10 seconds in between each number while entering the code. After pressing the [ENTER/STORE] key, the control panel will be in Program Mode and display P__1, with the '1' flashing. Press 2 on the keypad and then the [ENTER/STORE] key to select the Event Code/Transmission Formats Level for programming. You are allowed up to ten minutes of idle time at this point before starting your programming, otherwise, the control panel will go back to Normal Mode. You also have a maximum of 10 minutes between any key stroke. All entries made prior to the 10 minutes time-out are valid and are stored. Upon entering the Event Codes/Transmission Formats Level in programming mode, the following will be displayed on the FACP 7-Segment Display. 00_1 (address)(data) The first three locations on the left of the display represent the memory address 00 of the Format Chart previously selected in address 16 of the Main Panel Options section of programming mode. The last location 1 (farthest right) represents the contents of memory address 00 which is the format setting. The only value which can be altered in the Format Charts is the setting which is the last digit to the right. To change the value, key in the new digit. Use the Up and Down Arrow keys to increment to the next address or decrement to the previous address. When desired changes have been completed, exit programming mode by pressing the MODE key, followed by the 4-digit code for an alternate mode and then the [ENTER/STORE] key. To enter a different Programming Level, press MODE and then press the [ENTER/STORE] key. The display will show P__2 with the '2' flashing. Press the digit (1, 3 or 4) of the Programming Level to be accessed. During Program Mode, if no key is pressed within 10 minutes, the panel will revert to Normal Mode. The Format Charts which may be selected in the Main Panel Options (Level 1) section of the Programming Mode are shown on the following pages of this section. Format charts for the Primary and Secondary Central Station Numbers are included. Document #50193 Rev. D 5/2/97 P/N 50193:D 47 Program Options 3+1, 4+1 Express, 4+1 Standard and Expanded, 4+2 Expanded Formats If '0, 2, 3, 4, 5, 6, 7, 8, 9, B or D' are entered for address 16 in Program Mode Level 1, the data shown in Table 33 is automatically programmed for the Primary Central Station phone number event codes. Enter '0' for the setting to disable the report. TABLE 3-3: Event Codes, Primary Central Station Number Address 48 Description Setting 0 Primary # Zone 1 Alarm Code 11 1 Primary # Zone 2 Alarm Code 11 2 Primary # Zone 3 Alarm Code 11 3 Primary # Zone 4 Alarm Code 11 4 Primary # Zone 5 Alarm Code 11 5 Primary # Zone 6 Alarm Code 11 6 Primary # Zone 7 Alarm Code 11 7 Primary # Zone 8 Alarm Code 11 8 Primary # Zone 9 Alarm Code 11 9 Primary # Zone 10 Alarm Code 11 10 Primary # Zone 1 Disabled Code 4 11 Primary # Zone 2 Disabled Code 4 12 Primary # Zone 3 Disabled Code 4 13 Primary # Zone 4 Disabled Code 4 14 Primary # Zone 5 Disabled Code 4 15 Primary # Zone 6 Disabled Code 4 16 Primary # Zone 7 Disabled Code 4 17 Primary # Zone 8 Disabled Code 4 18 Primary # Zone 9 Disabled Code 4 19 Primary # Zone 10 Disabled Code 4 20 Primary # Drill Code 9 21 Primary # AC Fault Code 9 22 Primary # Zone 1 Fault Code F 23 Primary # Zone 2 Fault Code F 24 Primary # Zone 3 Fault Code F 25 Primary # Zone 4 Fault Code F 26 Primary # Zone 5 Fault Code F 27 Primary # Zone 6 Fault Code F 28 Primary # Zone 7 Fault Code F 29 Primary # Zone 8 Fault Code F 30 Primary # Zone 9 Fault Code F 31 Primary # Zone 10 Fault Code F 32 Primary # Earth Fault Code 6 33 Primary # Low Battery Fault Code 6 34 Primary # No Battery Fault Code 6 35 Primary # Telco Primary Line Fault Code 6 36 Primary # Telco Secondary Line Fault Code 6 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-3: Event Codes, Primary Central Station Number Address Description Setting 37 Primary # NAC #1 Fault Code 6 38 Primary # NAC #2 Fault Code 6 39 Primary # NAC #3 Fault Code 6 40 Primary # NAC #4 Fault Code 6 41 Primary # NAC #1 Disable Code 4 42 Primary # NAC #2 Disable Code 4 43 Primary # NAC #3 Disable Code 4 44 Primary # NAC #4 Disable Code 4 45 Primary # Comm Trouble Primary # Code 6 46 Primary # Comm Trouble Secondary # Code 6 47 Primary # Printer Fault Code 6 48 Primary # Annunciator Fault Code 6 49 Primary # 485 Comm Trouble Code 6 50 Primary # System Off Normal Code 6 51 Primary # Zone 1 Alarm Restore Code E 52 Primary # Zone 2 Alarm Restore Code E 53 Primary # Zone 3 Alarm Restore Code E 54 Primary # Zone 4 Alarm Restore Code E 55 Primary # Zone 5 Alarm Restore Code E 56 Primary # Zone 6 Alarm Restore Code E 57 Primary # Zone 7 Alarm Restore Code E 58 Primary # Zone 8 Alarm Restore Code E 59 Primary # Zone 9 Alarm Restore Code E 60 Primary # Zone 10 Alarm Restore Code E 61 Primary # Zone 1 Disabled Restore Code 5 62 Primary # Zone 2 Disabled Restore Code 5 63 Primary # Zone 3 Disabled Restore Code 5 64 Primary # Zone 4 Disabled Restore Code 5 65 Primary # Zone 5 Disabled Restore Code 5 66 Primary # Zone 6 Disabled Restore Code 5 67 Primary # Zone 7 Disabled Restore Code 5 68 Primary # Zone 8 Disabled Restore Code 5 69 Primary # Zone 9 Disabled Restore Code 5 70 Primary # Zone 10 Disabled Restore Code 5 71 Primary # Drill Restore Code 9 72 Primary # AC Fault Restore Code 9 73 Primary # Zone 1 Fault Restore Code D 74 Primary # Zone 2 Fault Restore Code D 75 Primary # Zone 3 Fault Restore Code D 76 Primary # Zone 4 Fault Restore Code D 77 Primary # Zone 5 Fault Restore Code D 78 Primary # Zone 6 Fault Restore Code D 79 Primary # Zone 7 Fault Restore Code D Document #50193 Rev. D 5/2/97 P/N 50193:D 49 Program Options TABLE 3-3: Event Codes, Primary Central Station Number Address Description Setting 80 Primary # Zone 8 Fault Restore Code D 81 Primary # Zone 9 Fault Restore Code D 82 Primary # Zone 10 Fault Restore Code D 83 Primary # Earth Fault Restore Code A 84 Primary #Low Battery Fault Restore Code A 85 Primary # No Battery Fault Restore Code A 86 Primary # Telco Primary Line Fault Restore Code A 87 Primary # Telco Secondary Line Fault Restore Code A 88 Primary # NAC #1 Fault Restore Code A 89 Primary # NAC #2 Fault Restore Code A 90 Primary # NAC #3 Fault Restore Code A 91 Primary # NAC #4 Fault Restore Code A 92 Primary # NAC #1 Disable Restore Code 5 93 Primary # NAC #2 Disable Restore Code 5 94 Primary # NAC #3 Disable Restore Code 5 95 Primary # NAC #4 Disable Restore Code 5 96 Primary # Comm Trouble Primary # Restore Code A 97 Primary # Comm Trouble Secondary # Restore Code A 98 Primary # Printer Fault Restore Code A 99 Primary # Annunciator Fault Restore Code A 100 Primary # 485 Comm Trouble Restore Code A 101 Primary # System Off Normal Restore Code A 102 Primary # System Test Report 9 103 Primary # System Abnormal Test Report F 104 Primary # Request for Up/Download 7 105 Primary # Successful Upload 7 106 Primary # Successful Download 7 107 Primary # Failed Up/Download 7 1. Zones programmed as supervisory alarm transmit as Code 8 instead of Code 1. 4+2 Standard and 4+2 Express Formats If '1, A or C' are entered for address 16 in Program Mode Level 1, the data shown in Table 3-4 is automatically programmed for the Primary Central Station phone number event codes. Enter '00' for the setting to disable the report. TABLE 3-4: Event Codes, Primary Central Station Number Address 50 Description Setting 0-1 Primary # Zone 1 Alarm Code 111 2-3 Primary # Zone 2 Alarm Code 121 4-5 Primary # Zone 3 Alarm Code 131 6-7 Primary # Zone 4 Alarm Code 141 8-9 Primary # Zone 5 Alarm Code 151 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-4: Event Codes, Primary Central Station Number Address Description Setting 10-11 Primary # Zone 6 Alarm Code 161 12-13 Primary # Zone 7 Alarm Code 171 14-15 Primary # Zone 8 Alarm Code 181 16-17 Primary # Zone 9 Alarm Code 191 18-19 Primary # Zone 10 Alarm Code 1A1 20-21 Primary # Zone 1 Disabled Code 41 22-23 Primary # Zone 2 Disabled Code 42 24-25 Primary # Zone 3 Disabled Code 43 26-27 Primary # Zone 4 Disabled Code 44 28-29 Primary # Zone 5 Disabled Code 45 30-31 Primary # Zone 6 Disabled Code 46 32-33 Primary # Zone 7 Disabled Code 47 34-35 Primary # Zone 8 Disabled Code 48 36-37 Primary # Zone 9 Disabled Code 49 38-39 Primary # Zone 10 Disabled Code 4A 40-41 Primary # Drill Code 97 42-43 Primary # AC Fault Code 92 44-45 Primary # Zone 1 Fault Code F1 46-47 Primary # Zone 2 Fault Code F2 48-49 Primary # Zone 3 Fault Code F3 50-51 Primary # Zone 4 Fault Code F4 52-53 Primary # Zone 5 Fault Code F5 54-55 Primary # Zone 6 Fault Code F6 56-57 Primary # Zone 7 Fault Code F7 58-59 Primary # Zone 8 Fault Code F8 60-61 Primary # Zone 9 Fault Code F9 62-63 Primary # Zone 10 Fault Code FA 64-65 Primary # Earth Fault Code 61 66-67 Primary # Low Battery Fault Code 62 68-69 Primary # No Battery Fault Code 63 70-71 Primary # Telco Primary Line Fault Code 64 72-73 Primary # Telco Secondary Line Fault Code 65 74-75 Primary # NAC #1 Fault Code 66 76-77 Primary # NAC #2 Fault Code 67 78-79 Primary # NAC #3 Fault Code 68 80-81 Primary # NAC #4 Fault Code 69 82-83 Primary # NAC #1 Disable Code 4B 84-85 Primary # NAC #2 Disable Code 4C 86-87 Primary # NAC #3 Disable Code 4D 88-89 Primary # NAC #4 Disable Code 4E 90-91 Primary # Comm Trouble Primary # Code 6A 92-93 Primary # Comm Trouble Secondary # Code 6B 94-95 Primary # Printer Fault Code 6C Document #50193 Rev. D 5/2/97 P/N 50193:D 51 Program Options TABLE 3-4: Event Codes, Primary Central Station Number Address 52 Description Setting 96-97 Primary # Annunciator Fault Code 6D 98-99 Primary # 485 Comm Trouble Code 6E 100-101 Primary # System Off Normal Code 6F 102-103 Primary # Zone 1 Alarm Restore Code E1 104-105 Primary # Zone 2 Alarm Restore Code E2 106-107 Primary # Zone 3 Alarm Restore Code E3 108-109 Primary # Zone 4 Alarm Restore Code E4 110-111 Primary # Zone 5 Alarm Restore Code E5 112-113 Primary # Zone 6 Alarm Restore Code E6 114-115 Primary # Zone 7 Alarm Restore Code E7 116-117 Primary # Zone 8 Alarm Restore Code E8 118-119 Primary # Zone 9 Alarm Restore Code E9 120-121 Primary # Zone 10 Alarm Restore Code EA 122-123 Primary # Zone 1 Disabled Restore Code 51 124-125 Primary # Zone 2 Disabled Restore Code 52 126-127 Primary # Zone 3 Disabled Restore Code 53 128-129 Primary # Zone 4 Disabled Restore Code 54 130-131 Primary # Zone 5 Disabled Restore Code 55 132-133 Primary # Zone 6 Disabled Restore Code 56 134-135 Primary # Zone 7 Disabled Restore Code 57 136-137 Primary # Zone 8 Disabled Restore Code 58 138-139 Primary # Zone 9 Disabled Restore Code 59 140-141 Primary # Zone 10 Disabled Restore Code 5A 142-143 Primary # Drill Restore Code 98 144-145 Primary # AC Fault Restore Code 93 146-147 Primary # Zone 1 Fault Restore Code D1 148-149 Primary # Zone 2 Fault Restore Code D2 150-151 Primary # Zone 3 Fault Restore Code D3 152-153 Primary # Zone 4 Fault Restore Code D4 154-155 Primary # Zone 5 Fault Restore Code D5 156-157 Primary # Zone 6 Fault Restore Code D6 158-159 Primary # Zone 7 Fault Restore Code D7 160-161 Primary # Zone 8 Fault Restore Code D8 162-163 Primary # Zone 9 Fault Restore Code D9 164-165 Primary # Zone 10 Fault Restore Code DA 166-167 Primary # Earth Fault Restore Code A1 168-169 Primary #Low Battery Fault Restore Code A2 170-171 Primary # No Battery Fault Restore Code A3 172-173 Primary # Telco Primary Line Fault Restore Code A4 174-175 Primary # Telco Secondary Line Fault Restore Code A5 176-177 Primary # NAC #1 Fault Restore Code A6 178-179 Primary # NAC #2 Fault Restore Code A7 180-181 Primary # NAC #3 Fault Restore Code A8 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-4: Event Codes, Primary Central Station Number Address Description Setting 182-183 Primary # NAC #4 Fault Restore Code A9 184-185 Primary # NAC #1 Disable Restore Code 5B 186-187 Primary # NAC #2 Disable Restore Code 5C 188-189 Primary # NAC #3 Disable Restore Code 5D 190-191 Primary # NAC #4 Disable Restore Code 5E 192-193 Primary # Comm Trouble Primary # Restore Code AA 194-195 Primary # Comm Trouble Secondary # Restore Code AB 196-197 Primary # Printer Fault Restore Code AC 198-199 Primary # Annunciator Fault Restore Code AD 200-201 Primary # 485 Comm Trouble Restore Code AE 201-203 Primary # System Off Normal Restore Code AF 204-205 Primary # System Test Report 99 206-207 Primary # System Abnormal Test Report 91 208-209 Primary # Request for Up/Download 71 210-211 Primary # Successful Upload 72 212-213 Primary # Successful Download 73 214-215 Primary # Failed Up/Download 74 1. Zones programmed as supervisory alarm transmit as 81, 82, 83, 84, 85, 86, 87, 88, 89, 8A (instead of 11, 12, 13, 14, 15, 16, 17, 18, 19, 1A). Ademco Contact ID Format If 'E' is entered for address 16 in Program Mode Level 1, the data shown in Table 3-5 is automatically programmed for the Primary Central Station phone number event codes. Enter '000' for the setting to disable the report. The Setting entry is programmable, the Zone Number cannot be changed. Restoral code settings match the settings shown with the addition of an 'R' code transmitted. Refer to page 111 for additional information. TABLE 3-5: Event Codes, Primary Central Station Number Address 0-2 Description Setting Primary # Zone 1 Alarm Code 111 Zone No. 1 001 1 3-5 Primary # Zone 2 Alarm Code 111 002 6-8 Primary # Zone 3 Alarm Code 1111 003 9-11 Primary # Zone 4 Alarm Code 1111 004 12-14 Primary # Zone 5 Alarm Code 1 111 005 15-17 Primary # Zone 6 Alarm Code 1111 006 18-20 Primary # Zone 7 Alarm Code 1111 007 21-23 Primary # Zone 8 Alarm Code 1111 008 24-26 Primary # Zone 9 Alarm Code 1111 009 27-29 Primary # Zone 10 Alarm Code 1111 010 30-32 Primary # Zone 1 Disabled Code 570 001 33-35 Primary # Zone 2 Disabled Code 570 002 36-38 Primary # Zone 3 Disabled Code 570 003 39-41 Primary # Zone 4 Disabled Code 570 004 42-44 Primary # Zone 5 Disabled Code 570 005 Document #50193 Rev. D 5/2/97 P/N 50193:D 53 Program Options TABLE 3-5: Event Codes, Primary Central Station Number Address Setting Zone No. 45-47 Primary # Zone 6 Disabled Code Description 570 006 48-50 Primary # Zone 7 Disabled Code 570 007 51-53 Primary # Zone 8 Disabled Code 570 008 54-56 Primary # Zone 9 Disabled Code 570 009 57-59 Primary # Zone 10 Disabled Code 570 010 60-62 Primary # Drill Code 604 000 63-65 Primary # AC Fault Code 301 000 66-68 Primary # Zone 1 Fault Code 380 001 69-71 Primary # Zone 2 Fault Code 380 002 72-74 Primary # Zone 3 Fault Code 380 003 75-77 Primary # Zone 4 Fault Code 380 004 78-80 Primary # Zone 5 Fault Code 380 005 81-83 Primary # Zone 6 Fault Code 380 006 84-86 Primary # Zone 7 Fault Code 380 007 87-89 Primary # Zone 8 Fault Code 380 008 90-92 Primary # Zone 9 Fault Code 380 009 93-95 Primary # Zone 10 Fault Code 380 010 96-98 Primary # Earth Fault Code 310 000 99-101 Primary # Low Battery Fault Code 302 000 102-104 Primary # No Battery Fault Code 311 000 105-107 Primary # Telco Primary Line Fault Code 351 000 108-110 Primary # Telco Secondary Line Fault Code 352 000 111-113 Primary # NAC #1 Fault Code 321 001 114-116 Primary # NAC #2 Fault Code 322 002 117-119 Primary # NAC #3 Fault Code 326 003 120-122 Primary # NAC #4 Fault Code 327 004 123-125 Primary # NAC #1 Disable Code 521 001 126-128 Primary # NAC #2 Disable Code 522 002 129-131 Primary # NAC #3 Disable Code 526 003 132-134 Primary # NAC #4 Disable Code 527 004 135-137 Primary # Comm Trouble Primary # Code 354 001 138-140 Primary # Comm Trouble Secondary # Code 354 002 141-143 Primary # Printer Fault Code 336 000 144-146 Primary # Annunciator Fault Code 330 001 147-149 Primary # 485 Comm Trouble Code 330 002 150-152 Primary # System Off Normal Code 308 000 153-155 Primary # System Test Message 602 000 156-158 Primary # System Abnormal Test Message 608 000 159-161 Primary # Upload/Download Request Code 411 000 162-164 Primary # Upload Successful Code 416 000 165-167 Primary # Download Successful Code 412 000 168-170 Primary # Upload/Download Failed Code 413 000 1. Refer to Table 3-1 for list of zone alarm event codes. 54 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options 3+1, 4+1 Express, 4+1 Standard and Expanded, 4+2 Expanded Formats If '0, 2, 3, 4, 5, 6, 7, 8, 9, B or D' are entered for address 42 in Program Mode Level 1, the data shown in Table 3-6 is automatically programmed for the Secondary Central Station phone number event codes. Enter '0' for the setting to disable the report. TABLE 3-6: Event Codes, Secondary Central Station Number Address Description Setting 216 Secondary # Zone 1 Alarm Code 11 217 Secondary # Zone 2 Alarm Code 11 218 Secondary # Zone 3 Alarm Code 11 219 Secondary # Zone 4 Alarm Code 11 220 Secondary # Zone 5 Alarm Code 11 221 Secondary # Zone 6 Alarm Code 11 222 Secondary # Zone 7 Alarm Code 11 223 Secondary # Zone 8 Alarm Code 11 224 Secondary # Zone 9 Alarm Code 11 225 Secondary # Zone 10 Alarm Code 11 226 Secondary # Zone 1 Disabled Code 4 227 Secondary # Zone 2 Disabled Code 4 228 Secondary # Zone 3 Disabled Code 4 229 Secondary # Zone 4 Disabled Code 4 230 Secondary # Zone 5 Disabled Code 4 231 Secondary # Zone 6 Disabled Code 4 232 Secondary # Zone 7 Disabled Code 4 233 Secondary # Zone 8 Disabled Code 4 234 Secondary # Zone 9 Disabled Code 4 235 Secondary # Zone 10 Disabled Code 4 236 Secondary # Drill Code 9 237 Secondary # AC Fault Code 9 238 Secondary # Zone 1 Fault Code F 239 Secondary # Zone 2 Fault Code F 240 Secondary # Zone 3 Fault Code F 241 Secondary # Zone 4 Fault Code F 242 Secondary # Zone 5 Fault Code F 243 Secondary # Zone 6 Fault Code F 244 Secondary # Zone 7 Fault Code F 245 Secondary # Zone 8 Fault Code F 246 Secondary # Zone 9 Fault Code F 247 Secondary # Zone 10 Fault Code F 248 Secondary # Earth Fault Code 6 249 Secondary # Low Battery Fault Code 6 250 Secondary # No Battery Fault Code 6 251 Secondary # Telco Primary Line Fault Code 6 252 Secondary # Telco Secondary Line Fault Code 6 253 Secondary # NAC #1 Fault Code 6 Document #50193 Rev. D 5/2/97 P/N 50193:D 55 Program Options TABLE 3-6: Event Codes, Secondary Central Station Number Address 56 Description Setting 254 Secondary # NAC #2 Fault Code 6 255 Secondary # NAC #3 Fault Code 6 256 Secondary # NAC #4 Fault Code 6 257 Secondary # NAC #1 Disable Code 4 258 Secondary # NAC #2 Disable Code 4 259 Secondary # NAC #3 Disable Code 4 260 Secondary # NAC #4 Disable Code 4 261 Secondary # Comm Trouble Primary # Code 6 262 Secondary # Comm Trouble Secondary # Code 6 263 Secondary # Printer Fault Code 6 264 Secondary # Annunciator Fault Code 6 265 Secondary # 485 Comm Trouble Code 6 266 Secondary # System Off Normal Code 6 267 Secondary # Zone 1 Alarm Restore Code E 268 Secondary # Zone 2 Alarm Restore Code E 269 Secondary # Zone 3 Alarm Restore Code E 270 Secondary # Zone 4 Alarm Restore Code E 271 Secondary # Zone 5 Alarm Restore Code E 272 Secondary # Zone 6 Alarm Restore Code E 273 Secondary # Zone 7 Alarm Restore Code E 274 Secondary # Zone 8 Alarm Restore Code E 275 Secondary # Zone 9 Alarm Restore Code E 276 Secondary # Zone 10 Alarm Restore Code E 277 Secondary # Zone 1 Disabled Restore Code 5 278 Secondary # Zone 2 Disabled Restore Code 5 279 Secondary # Zone 3 Disabled Restore Code 5 280 Secondary # Zone 4 Disabled Restore Code 5 281 Secondary # Zone 5 Disabled Restore Code 5 282 Secondary # Zone 6 Disabled Restore Code 5 283 Secondary # Zone 7 Disabled Restore Code 5 284 Secondary # Zone 8 Disabled Restore Code 5 285 Secondary # Zone 9 Disabled Restore Code 5 286 Secondary # Zone 10 Disabled Restore Code 5 287 Secondary # Drill Restore Code 9 288 Secondary # AC Fault Restore Code 9 289 Secondary # Zone 1 Fault Restore Code D 290 Secondary # Zone 2 Fault Restore Code D 291 Secondary # Zone 3 Fault Restore Code D 292 Secondary # Zone 4 Fault Restore Code D 293 Secondary # Zone 5 Fault Restore Code D 294 Secondary # Zone 6 Fault Restore Code D 295 Secondary # Zone 7 Fault Restore Code D 296 Secondary # Zone 8 Fault Restore Code D Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-6: Event Codes, Secondary Central Station Number Address Description Setting 297 Secondary # Zone 9 Fault Restore Code D 298 Secondary # Zone 10 Fault Restore Code D 299 Secondary # Earth Fault Restore Code A 300 Secondary #Low Battery Fault Restore Code A 301 Secondary # No Battery Fault Restore Code A 302 Secondary # Telco Primary Line Fault Restore Code A 303 Secondary # Telco Secondary Line Fault Restore Code A 304 Secondary # NAC #1 Fault Restore Code A 305 Secondary # NAC #2 Fault Restore Code A 306 Secondary # NAC #3 Fault Restore Code A 307 Secondary # NAC #4 Fault Restore Code A 308 Secondary # NAC #1 Disable Restore Code 5 309 Secondary # NAC #2 Disable Restore Code 5 310 Secondary # NAC #3 Disable Restore Code 5 311 Secondary # NAC #4 Disable Restore Code 5 312 Secondary # Comm Trouble Primary # Restore Code A 313 Secondary # Comm Trouble Secondary # Restore Code A 314 Secondary # Printer Fault Restore Code A 315 Secondary # Annunciator Fault Restore Code A 316 Secondary # 485 Comm Trouble Restore Code A 317 Secondary # System Off Normal Restore Code A 318 Secondary # System Test Report 9 319 Secondary # System Abnormal Test Report F 320 Secondary # Request for Up/Download 7 321 Secondary # Successful Upload 7 322 Secondary # Successful Download 7 323 Secondary # Failed Up/Download 7 1. Zones programmed as supervisory alarm transmit as Code 8 instead of Code 1. 4+2 Standard and 4+2 Express Formats If '1, A or C' are entered for address 42 in Program Mode Level 1, the data shown in Table 3-7 is automatically programmed for the Secondary Central Station phone number event codes. Enter '00' for the setting to disable the report. TABLE 3-7: Event Codes, Secondary Central Station Number Address Description Setting 216-217 Secondary # Zone 1 Alarm Code 111 218-219 Secondary # Zone 2 Alarm Code 121 220-221 Secondary # Zone 3 Alarm Code 131 222-223 Secondary # Zone 4 Alarm Code 141 224-225 Secondary # Zone 5 Alarm Code 151 226-227 Secondary # Zone 6 Alarm Code 161 Document #50193 Rev. D 5/2/97 P/N 50193:D 57 Program Options TABLE 3-7: Event Codes, Secondary Central Station Number Address 58 Description Setting 228-229 Secondary # Zone 7 Alarm Code 171 230-231 Secondary # Zone 8 Alarm Code 181 232-233 Secondary # Zone 9 Alarm Code 191 234-235 Secondary # Zone 10 Alarm Code 1A1 236-237 Secondary # Zone 1 Disabled Code 41 238-239 Secondary # Zone 2 Disabled Code 42 240-241 Secondary # Zone 3 Disabled Code 43 242-243 Secondary # Zone 4 Disabled Code 44 244-245 Secondary # Zone 5 Disabled Code 45 246-247 Secondary # Zone 6 Disabled Code 46 248-249 Secondary # Zone 7 Disabled Code 47 250-251 Secondary # Zone 8 Disabled Code 48 252-253 Secondary # Zone 9 Disabled Code 49 254-255 Secondary # Zone 10 Disabled Code 4A 256-257 Secondary # Drill Code 97 258-259 Secondary # AC Fault Code 92 260-261 Secondary # Zone 1 Fault Code F1 262-263 Secondary # Zone 2 Fault Code F2 264-265 Secondary # Zone 3 Fault Code F3 266-267 Secondary # Zone 4 Fault Code F4 268-269 Secondary # Zone 5 Fault Code F5 270-271 Secondary # Zone 6 Fault Code F6 272-273 Secondary # Zone 7 Fault Code F7 274-275 Secondary # Zone 8 Fault Code F8 276-277 Secondary # Zone 9 Fault Code F9 278-279 Secondary # Zone 10 Fault Code FA 280-281 Secondary # Earth Fault Code 61 282-283 Secondary # Low Battery Fault Code 62 284-285 Secondary # No Battery Fault Code 63 286-287 Secondary # Telco Primary Line Fault Code 64 288-289 Secondary # Telco Secondary Line Fault Code 65 290-291 Secondary # NAC #1 Fault Code 66 292-293 Secondary # NAC #2 Fault Code 67 294-295 Secondary # NAC #3 Fault Code 68 296-297 Secondary # NAC #4 Fault Code 69 298-299 Secondary # NAC #1 Disable Code 4B 300-301 Secondary # NAC #2 Disable Code 4C 302-303 Secondary # NAC #3 Disable Code 4D 304-305 Secondary # NAC #4 Disable Code 4E 306-307 Secondary # Comm Trouble Primary # Code 6A 308-309 Secondary # Comm Trouble Secondary # Code 6B 310-311 Secondary # Printer Fault Code 6C Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-7: Event Codes, Secondary Central Station Number Address Description Setting 312-313 Secondary # Annunciator Fault Code 6D 314-315 Secondary # 485 Comm Trouble Code 6E 316-317 Secondary # System Off Normal Code 6F 318-319 Secondary # Zone 1 Alarm Restore Code E1 320-321 Secondary # Zone 2 Alarm Restore Code E2 322-323 Secondary # Zone 3 Alarm Restore Code E3 324-325 Secondary # Zone 4 Alarm Restore Code E4 326-327 Secondary # Zone 5 Alarm Restore Code E5 328-329 Secondary # Zone 6 Alarm Restore Code E6 330-331 Secondary # Zone 7 Alarm Restore Code E7 332-333 Secondary # Zone 8 Alarm Restore Code E8 334-335 Secondary # Zone 9 Alarm Restore Code E9 336-337 Secondary # Zone 10 Alarm Restore Code EA 338-339 Secondary # Zone 1 Disabled Restore Code 51 340-341 Secondary # Zone 2 Disabled Restore Code 52 342-343 Secondary # Zone 3 Disabled Restore Code 53 344-345 Secondary # Zone 4 Disabled Restore Code 54 346-347 Secondary # Zone 5 Disabled Restore Code 55 348-349 Secondary # Zone 6 Disabled Restore Code 56 350-351 Secondary # Zone 7 Disabled Restore Code 57 352-353 Secondary # Zone 8 Disabled Restore Code 58 354-355 Secondary # Zone 9 Disabled Restore Code 59 356-357 Secondary # Zone 10 Disabled Restore Code 5A 358-359 Secondary # Drill Restore Code 98 360-361 Secondary # AC Fault Restore Code 93 362-363 Secondary # Zone 1 Fault Restore Code D1 364-365 Secondary # Zone 2 Fault Restore Code D2 366-367 Secondary # Zone 3 Fault Restore Code D3 368-369 Secondary # Zone 4 Fault Restore Code D4 370-371 Secondary # Zone 5 Fault Restore Code D5 372-373 Secondary # Zone 6 Fault Restore Code D6 374-375 Secondary # Zone 7 Fault Restore Code D7 376-377 Secondary # Zone 8 Fault Restore Code D8 378-379 Secondary # Zone 9 Fault Restore Code D9 380-381 Secondary # Zone 10 Fault Restore Code DA 382-383 Secondary # Earth Fault Restore Code A1 384-385 Secondary #Low Battery Fault Restore Code A2 386-387 Secondary # No Battery Fault Restore Code A3 388-389 Secondary # Telco Primary Line Fault Restore Code A4 390-391 Secondary # Telco Secondary Line Fault Restore Code A5 392-393 Secondary # NAC #1 Fault Restore Code A6 394-395 Secondary # NAC #2 Fault Restore Code A7 396-397 Secondary # NAC #3 Fault Restore Code A8 Document #50193 Rev. D 5/2/97 P/N 50193:D 59 Program Options TABLE 3-7: Event Codes, Secondary Central Station Number Address Description Setting 398-399 Secondary # NAC #4 Fault Restore Code A9 400-401 Secondary # NAC #1 Disable Restore Code 5B 402-403 Secondary # NAC #2 Disable Restore Code 5C 404-405 Secondary # NAC #3 Disable Restore Code 5D 406-407 Secondary # NAC #4 Disable Restore Code 5E 408-409 Secondary # Comm Trouble Primary # Restore Code AA 410-411 Secondary # Comm Trouble Secondary # Restore Code AB 412-413 Secondary # Printer Fault Restore Code AC 414-415 Secondary # Annunciator Fault Restore Code AD 416-417 Secondary # 485 Comm Trouble Restore Code AE 418-419 Secondary # System Off Normal Restore Code AF 420-421 Secondary # System Test Report 99 422-423 Secondary # System Abnormal Test Report 91 424-425 Secondary # Request for Up/Download 71 426-427 Secondary # Successful Upload 72 428-429 Secondary # Successful Download 73 430-431 Secondary # Failed Up/Download 74 1. Zones programmed as supervisory alarm transmit as 81, 82, 83, 84, 85, 86, 87, 88, 89, 8A. Ademco Contact ID Format If 'E' is entered for address 42 in Program Mode Level 1, the data shown in Table 3-8 is automatically programmed for the Secondary Central Station phone number event codes. Enter '000' for the setting to disable the report. The Setting entry is programmable, the Zone Number cannot be changed. Restoral code settings match the settings shown with the addition of an 'R' code transmitted. Refer to page 101 for additional information. TABLE 3-8: Event Codes, Secondary Central Station Number Address 216-218 60 Description Setting Secondary # Zone 1 Alarm Code Zone No. 1 001 1 111 219-221 Secondary # Zone 2 Alarm Code 111 002 222-224 Secondary # Zone 3 Alarm Code 1111 003 225-227 Secondary # Zone 4 Alarm Code 1111 004 228-230 Secondary # Zone 5 Alarm Code 1111 005 231-233 Secondary # Zone 6 Alarm Code 1111 006 234-236 Secondary # Zone 7 Alarm Code 1111 007 237-239 Secondary # Zone 8 Alarm Code 1 111 008 240-242 Secondary # Zone 9 Alarm Code 1111 009 243-245 Secondary # Zone 10 Alarm Code 1111 010 246-248 Secondary # Zone 1 Disabled Code 570 001 249-251 Secondary # Zone 2 Disabled Code 570 002 252-254 Secondary # Zone 3 Disabled Code 570 003 255-257 Secondary # Zone 4 Disabled Code 570 004 258-260 Secondary # Zone 5 Disabled Code 570 005 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options TABLE 3-8: Event Codes, Secondary Central Station Number Address Description Setting Zone No. 261-263 Secondary # Zone 6 Disabled Code 570 006 264-266 Secondary # Zone 7 Disabled Code 570 007 267-269 Secondary # Zone 8 Disabled Code 570 008 270-272 Secondary # Zone 9 Disabled Code 570 009 273-275 Secondary # Zone 10 Disabled Code 570 010 276-278 Secondary # Drill Code 604 000 279-281 Secondary # AC Fault Code 301 000 282-284 Secondary # Zone 1 Fault Code 380 001 285-287 Secondary # Zone 2 Fault Code 380 002 288-290 Secondary # Zone 3 Fault Code 380 003 291-293 Secondary # Zone 4 Fault Code 380 004 294-296 Secondary # Zone 5 Fault Code 380 005 297-299 Secondary # Zone 6 Fault Code 380 006 300-302 Secondary # Zone 7 Fault Code 380 007 303-305 Secondary # Zone 8 Fault Code 380 008 306-308 Secondary # Zone 9 Fault Code 380 009 309-311 Secondary # Zone 10 Fault Code 380 010 312-314 Secondary # Earth Fault Code 310 000 315-317 Secondary # Low Battery Fault Code 302 000 318-320 Secondary # No Battery Fault Code 311 000 321-323 Secondary # Telco Primary Line Fault Code 351 000 324-326 Secondary # Telco Secondary Line Fault Code 352 000 327-329 Secondary # NAC #1 Fault Code 321 001 330-332 Secondary # NAC #2 Fault Code 322 002 333-335 Secondary # NAC #3 Fault Code 326 003 336-338 Secondary # NAC #4 Fault Code 327 004 339-341 Secondary # NAC #1 Disable Code 521 001 342-344 Secondary # NAC #2 Disable Code 522 002 345-347 Secondary # NAC #3 Disable Code 526 003 348-350 Secondary # NAC #4 Disable Code 527 004 351-353 Secondary # Comm Trouble Primary # Code 354 001 354-356 Secondary # Comm Trouble Secondary # Code 354 002 357-359 Secondary # Printer Fault Code 336 000 360-362 Secondary # Annunciator Fault Code 330 001 363-365 Secondary # 485 Comm Trouble Code 330 002 366-368 Secondary # System Off Normal Code 308 000 369-371 Secondary # System Test Message 602 000 372-374 Secondary # System Abnormal Test Message 608 000 375-377 Secondary # Upload/Download Request Code 411 000 378-380 Secondary # Upload Successful Code 416 000 381-383 Secondary # Download Successful Code 412 000 384-386 Secondary # Upload/Download Failed Code 413 000 1. Refer to Table 3-1 for a list of zone alarm event codes. Document #50193 Rev. D 5/2/97 P/N 50193:D 61 Program Options 3.3.3 Level Three - Option Module Selections Each option of the Program Mode is entered by keying in the program mode entry code (7764) and pressing the [ENTER/STORE] key. ☛ 7764 spells PROG on a Touch-Tone® phone If an incorrect key is entered, reenter the proper 4-digit code before pressing the [ENTER/STORE] key. You are allowed a pause of up to 10 seconds in between each number while entering the code. After pressing the [ENTER/STORE] key, the control panel will be in Program Mode and display P__1, with the '1' flashing. Press 3 on the keypad and then the [ENTER/STORE] key to choose the Option Module Selections. You are allowed up to ten minutes of idle time at this point before starting your programming, otherwise, the control panel will return to Normal Mode. You also have a maximum of 10 minutes between any keystroke. All entries made prior to the 10 minute time-out are valid and are stored. Upon entering the Option Modules Selections in programming mode, the following will be displayed on the FACP 7-Segment Display. 00_0 (address)(data) The first three locations on the left of the display represent the memory address 00 of the first Option Module (CAC-10F Converter Card). The last location 0 (farthest right) represents the contents of memory address '00', which indicates that the card is not installed. To install the card, press '1' on the keypad. Use the Up and Down Arrow keys to increment to the next address or decrement to the previous address. When desired changes have been completed, exit programming mode by pressing the MODE key, followed by the 4-digit code for an alternate mode and then the [ENTER/STORE] key. To enter a different Programming Level, press MODE and then press the [ENTER/STORE] key. The display will show P__3 with the '3' flashing. Press the digit (1, 2 or 4) of the Programming Level to be accessed. During Program Mode, if no key is pressed within 10 minutes, the panel will revert to Normal Mode. Following are the various option modules and their addresses. CAC-10F Class A Converter Card (00) The factory default entry of '0' in address 00 informs the FACP that there is no CAC-10F Class A Converter Card installed in the panel. When a CAC-10F is installed, '1' must be entered for this address. LED-10IM EIA-485 Interface Module (01) The factory default entry of '0' indicates to the panel that an LED-10IM is not installed. Enter a '1' in address 01 if an LED-10IM EIA-485 Interface Module is installed. Annunciator Maximum Monitored Address (02-03) Annunciator addresses may be set from a value of '01' through '32'. Enter the value of the highest or maximum address value selected on any annunciator or ACM-8RF connected to the EIA-485 port off of the LED-10IM module. Devices which may be connected to the EIA-485 port include LDM graphic annunciators, AFM LED type annunciators, LED-10 Series annunciators and ACM-8RF relay modules. Included on the LDM, LED-10 Series and ACM-8RF are switches which select an address from 01 to 32. For each device added or connected to the EIA-485 port via the LED-10IM, select an address on each, with the exception of the ACM-8RF (refer to the applications section of the ACM-8RF Manual). Addresses must be sequential with no gaps allowed. For example, if 13 devices are connected to the EIA-845 port, the maximum monitored address value entered into locations 02-03 must be 02 = '1' and 02 = '3'. If 25 devices are connected to the EIA-485 port, the maximum monitored address entered into locations 02-03 must be 02 = '2' and 03 = '5'. 62 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options All devices connected to the EIA-485 are fully supervised by the FACP. Note that AFM series annunciators occupy address '01'. The address of the AFM series cannot be altered. When using AFM series devices with LDMs, LED-10 Series and ACM-8RFs, be certain that none of the other devices are set to address '01'. Factory default entry is 02 = 0 and 03 = 1. Printer Installed (04) The factory default entry of '0' in address 04 informs the FACP that a printer is not connected to the panel. This entry must be changed to '1' if a printer is connected. The PRT-24 printer interface module must be installed on J4 of the MS-5210UD main circuit board before a printer can be installed. Printer Baud Rate (05) Address 05 is used to set the Baud Rate when a printer is connected to the MS-5210UD. The factory default entry is '0' for 2400 Baud. Enter '1' for 4800 Baud or '2' for 9600 Baud. An entry in address 05 is valid only if a printer has been enabled in address 04. NAC/Relay Option Module (06) A Notification Appliance Circuit/Relay Option (NAC-REM) Module is available which adds two Style Z (Class A) NAC circuits (NACs 3 and 4) and two programmable Form-C relays (Relays 3 and 4). The factory default setting for address 06 is '0' for no module installed. This entry must be changed to '1' if the NAC/Relay module is installed. Programmable Relay 3 Definition (07) This address programs Relay 3 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for Relay 3 is '1' for supervisory. Enter '0' for alarm; '2' for supervisory autoresettable; '3' for trouble; '4' for communication fail; '5' for process monitoring; '6' for autoresettable process monitoring. Programmable Relay 4 Definition (08) This address programs Relay 4 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for Relay 4 is '4' for communication fail. Enter '0' for alarm; '1' for supervisory; '2' for supervisory autoresettable; '3' for trouble; '5' for process monitoring; '6' for autoresettable process monitoring. NAC #3 Type Selection (09) This address programs NAC #3 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #3 is '0' for enabled and silenceable. Enter '1' for enabled and nonsilenceable or '2' for disabled. NAC #3 Silence Inhibit (10) This address is used for the silence inhibit feature on NAC #3 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #3 is '0' for no silence inhibit. Enter '1' to enable the silence inhibit feature for NAC #3. This will prevent the silencing of NAC #3 for one minute following activation of an alarm. NAC #3 Autosilence (11) This address is used for the autosilence feature on NAC #3 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #3 is '0' for no autosilence. If you wish NAC #3 to be automatically silenced after one of the following lengths of time (requires prior approval of Local AHJ), enter '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; or '6' for 30 minutes. NAC #3 Signal Coding (12) This address is used to select coding for NAC #3 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #3 is '0' for steady output (no coding). Enter '1' for March Time coding (120 ppm); '2' for California Time coding (10 secs. On, 5 secs. Off); or '3' for Temporal Time coding (½ sec. On, ½ sec. Off, ½ sec. On, ½ sec. Off, ½ sec. On, 1½ secs. Off, and then repeat sequence). Document #50193 Rev. D 5/2/97 P/N 50193:D 63 Program Options NAC #4 Type Selection (13) This address programs NAC #4 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #4 is '0' for enabled and silenceable. Enter '1' for enabled and nonsilenceable or '2' for disabled. NAC #4 Silence Inhibit (14) This address is used for the silence inhibit feature on NAC #4 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #4 is '0' for no silence inhibit. Enter '1' to enable the silence inhibit feature for NAC #4. This will prevent the silencing of NAC #4 for one minute following activation of an alarm. NAC #4 Autosilence (15) This address is used for the autosilence feature on NAC #4 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #4 is '0' for no autosilence. If you wish NAC #4 to be automatically silenced after one of the following lengths of time (requires prior approval of Local AHJ), enter '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; or '6' for 30 minutes. NAC #4 Signal Coding (16) This address is used to select coding for NAC #4 if the NAC/Relay Option Module has been enabled in address 06. The factory default entry for NAC #4 is '0' for steady output (no coding). Enter '1' for March Time coding (120 ppm); '2' for California Time coding (10 secs. On, 5 secs. Off); or '3' for Temporal Time coding (½ sec. On, ½ sec. Off, ½ sec. On, ½ sec. Off, ½ sec. On, 1½ secs. Off, and then repeat sequence). Canadian Supervisory Annunciation (17) This address, when programmed to a '1', causes the annunciators (LDM, AFM, LED-10 Series) to indicate a supervisory alarm by turning on the appropriate yellow zone LED only. The yellow zone LED blinks at a ½ second ON/½ second OFF rate in alarm. It blinks at a 1 second ON/1 second OFF rate if the supervisory zone is in fault. Should both an alarm and a fault occur on a supervisory zone at the same time, the alarm takes priority and the blink rate is ½ second ON/½ second OFF. The non-Canadian supervisory function will turn on the red zone alarm LED for any type of zone function. The blink rate at the annunciators is 1 second ON/1 second OFF for fire alarm, ½ second ON/½ second OFF for supervisory alarm and ¼ second ON/¼ second OFF for process monitored alarm. The default entry is '0' for non-Canadian supervisory annunciation. Enter '1' for Canadian Supervisory Annunciation. Note: UL and ULC require slide-in labels on all annunciators to be clearly marked as to the function of each zone. ! CAUTION: When selecting this function, be aware that ACM-8RF relays programmed for alarm will not activate for supervisory alarms. 3.3.4 Level Four - Upload/Download Option Each option of the Program Mode is entered by keying in the program mode entry code (7764) and pressing the [ENTER/STORE] key. ☛ 7764 spells PROG on a Touch-Tone® phone If an incorrect key is entered, reenter the proper 4-digit code before pressing the [ENTER/STORE] key. You are allowed a pause of up to 10 seconds in between each number while entering the code. After pressing the [ENTER/STORE] key, the control panel will be in Program Mode and display P__1, with the '1' flashing. Press 4 on the keypad and then the [ENTER/STORE] key to choose the Upload/Download Option. You are allowed up to ten minutes of idle time at this point before starting your programming, otherwise, the control panel will return to Normal Mode. You also have a maximum of 10 minutes between any key stroke. All entries made prior to the 10 minute time-out are valid and are stored. 64 Document #50193 Rev.D 5/2/97 P/N 50193:D Program Options Upon entering the Upload/Download Option in programming mode, the following will be displayed on the FACP LCD. 00_0 (address)(data) The first three locations on the left of the display represent the memory address 00. The last location 0 (farthest right) represents the contents of memory address 00 which is the first digit of the Panel Identification Number. To change the Panel ID Number, key in the first of the four digits for the ID. Increment to the next address and key in the second number. Continue until all digits are programmed. Use the Up and Down Arrow keys to increment to the next address or decrement to the previous address. When desired changes have been completed, exit programming mode by pressing the MODE key, followed by the 4-digit code for an alternate mode and then the [ENTER/STORE] key. To enter a different Programming Level, press MODE and then press the [ENTER/STORE] key. The display will show P__4 with the '4' flashing. Press the digit (1, 2 or 3) of the Programming Level to be accessed. During Program Mode, if no key is pressed within 10 minutes, the panel will revert to Normal Mode. The MS-5210UD can be programmed remotely from a PC using a modem and the telephone line. Information can also be retrieved from the FACP with the same method. The Upload/Download Option allows an operator to set the necessary parameters to allow the uploading and downloading of data between the FACP and PC. Following are the various parameters and their addresses. Panel Identification Number (00-03) The Panel Identification Number is a 4-digit code (valid digits being 0-F) that is used to identify the installed panel. This code is separate form the 8-digit secret code loaded in by the Service Terminal. It is important to program this 4-digit code at the job site the first time that downloading is performed so that the called Service Terminal can identify the control panel. Factory default is '0000'. (Future use). Service Terminal Number 1 Phone Number (04-19) Addresses 04 through 19 are reserved for the Service Terminal Number 1 phone number. Factory default is all Fs. Valid entries are 0-9 plus A, B, C, D and E. Use 'F' to designate the end of the phone number. Ring Count on Primary Phone Line (20-21) Use this address to designate the number of rings allowed on the primary phone line prior to answering an incoming call from a Service Terminal. Factory default is 25 meaning the panel will not answer an incoming call until 25 rings are detected. This entry may be programmed up to a maximum of 25 rings. A setting of 00 prevents the panel from answering incoming calls. FAX/Answer Machine, Primary Phone Line (22) This entry is used when the primary phone line is being shared with a FAX, answering machine or other device. Factory default is '0', no sharing of the primary phone line. An entry of '1' indicates that another device is sharing the primary phone line. The panel will wait for three consecutive calls from the Service Terminal spaced 30 seconds apart, before responding. Service Terminal Number 2 Phone Number (23-38) Addresses 23 through 38 are reserved for the Service Terminal Number 2 phone number. Factory default is all Fs. Valid entries are 0-9 plus A, B, C, D and E. Use 'F' to designate the end of the phone number. Ring Count on Secondary Phone Line (39-40) Use this address to designate the number of rings allowed on the secondary phone line prior to answering an incoming call from a Service Terminal. Factory default is 25, meaning the panel will not answer an incoming call until 25 rings are detected. This entry affects the secondary phone line only. This entry may be programmed up to a maximum of 25 rings. A setting of 00 prevents the panel from answering incoming calls. Document #50193 Rev. D 5/2/97 P/N 50193:D 65 Program Options FAX/Answer Machine, Secondary Phone Line (41) Factory default is '0' for no sharing of the secondary phone line with a FAX, answering machine or other device. An entry of '1' allows the panel to wait for three consecutive calls spaced 30 seconds apart from the Service Terminal before responding. Upload/Download Reports Sent to Secondary Central Station Phone #, Backup or Always (42) Leaving address 42 = 0 means that reports for request for 'upload/download', 'successful upload', 'successful download' and 'failed upload/download' will be sent to the secondary Central Station phone number only if attempts to the primary Central Station phone number are unsuccessful. Programming a '1' causes all reports to be transmitted to both primary and secondary phone numbers. Factory default is '0' for secondary backup only. Enter '1' to transmit to both Central Station phone numbers. Enter '2' to transmit to the first available receiver. ! CAUTION: Do not alter entry while the communicator is active. 3.3.5 Default Programming To return all program entries in all four levels to their factory original settings, perform the following steps only when the system is idle in Normal standby condition: Press the MODE key followed by the 4-digit code 3337 and press the [ENTER/STORE] key. ☛ 3337 spells DEFP (DEFault Programming) on a Touch-Tone® phone. If an incorrect key is entered, reenter the proper 4-digit code before pressing the [ENTER/STORE] key. Within five seconds, repeat this entry by again pressing the MODE key followed by the 4-digit code 3337 and pressing the [ENTER/STORE] key. The display will read 3337 while the E2 nonvolatile memory (storage area for all programming options) is being reprogrammed with the original default settings. When reprogramming is complete, the display will be blank. 66 Document #50193 Rev.D 5/2/97 P/N 50193:D Operating Instructions CHAPTER 4 Operating Instructions FIGURE 4-1: New and Old Keypad/Display New - with ACK lettering Old - without ACK lettering The MS-5210UD has several modes of operation including Normal, Program, Walk Test, Troubleshoot, History, Lamp Test, Print and Upload/Download. There are also four function modes which include Drill, Zone Enable/Disable, NAC Enable/Disable and Default Programming. Upon initial power-up, the system will be in Normal Mode. This section discusses operation of the control panel in the Normal Mode. 4.1 Switch Functions in Normal Mode RESET The System Reset switches reset the system and any smoke detectors. Reset switches may be located on the FACP keypad (illustrated in Figure 4-1), any of the ten zones programmed as a remote reset switch, remotely on any of the LED-10 Series annunciators, the LDM graphic annunciators, or the AFM series annunciators. If any of the System Reset Switches are pressed, the control panel will: ✓ Clear the display and status LEDs ✓ Turn off the Notification Appliance Circuits ✓ Reset all zones by temporarily removing power ✓ Silence the onboard piezo sounder ✓ Store 'reset' message in the History file ✓ Restore all system relays to normal ✓ Temporarily remove power from the resettable power output TB2 Terminals 3 and 4 ✓ Output 'reset' message to printer Any alarm, supervisory or trouble condition that exists after a system reset, will resound the system, reactivating normal system activity. Upon release of a System Reset Switch, the FACP display will read rES_ for 6 seconds. SILENCE Silence switches may be located on the FACP keypad (illustrated in Figure 4-1), any of the ten zones programmed as a remote silence switch, remotely located on any of the LED-10 Series annunciators, the LDM graphic annunciators, or the AFM series annunciators. The Silence Switch performs the same functions as the System Acknowledge switch. In addition, if any of the System Silence switches are pressed, the following will occur: ✓ The silenceable Notification Appliance Circuits will be turned OFF Document #50193 Rev. D 5/2/97 P/N 50193:D 67 Switch Functions in Normal Mode ✓ The main circuit board silence LED will be turned ON ✓ The SILn message will be displayed (where n = NAC #) ✓ The system piezo sounders will be shut OFF ✓ 'NAC #N Silenced' message will be stored in the History file ✓ 'NAC #N Silenced' message will be sent to the printer Upon the occurrence of a subsequent event (alarm or trouble), System Silence is overridden and the control panel will respond to the new event. The System Silence switches will be ignored for nonsilenceable waterflow type alarms. ACKNOWLEDGE/STEP Acknowledge/Step switches (Up/Down arrow keys) are located on newer model FACP keypads (refer to Figure 41), remotely located on any of the LED-10 Series annunciators, the LDM graphic annunciators, or the AFM series annunciators and an option exists that allows any of the ten zones to be programmed to function as a remote Acknowledge switch. The Acknowledge/Step switch silences the system piezo sounders and changes all flashing system LEDs to steady. An acknowledge message is sent to the printer and history files. The Step function permits scrolling through multiple stored events during normal, history and walktest modes. When more than one event exists, the first press of the Acknowledge/Step switch silences the system piezo sounders and changes all flashing system LEDs to steady. The second press of the switch stops the scrolling and holds the event on the display for five seconds. Subsequent pressing of the switch 'steps' through each active event. The Acknowledge/Step switch must be pressed within 15 seconds to prevent NACs from turning on if alarm presignal is selected. For additional information on alarm presignal, refer to “Programming Instructions” on page 37. Note: Software P/N: MS-52102.0 or greater supports the Acknowledge key function at the FACP keypad. DRILL Drill switches may be located on any of the ten zones programmed as a remote drill switch, remotely on any of the LED-10 Series annunciators, the LDM graphic annunciators, or the AFM series annunciators. To perform a drill from any of these switches, the Drill switch must be pressed and held for two seconds (time to prevent accidental activation). The MS-5210UD turns on all NACs and turns off the system silence LEDs. The message shown on the display is dril. The drill message is sent to the printer and history files. The system silence keys will silence all silenceable NACs during a fire drill. To perform a drill from the FACP, press the MODE key followed by the code 3745 then press [ENTER/STORE]. The display will read dril. The alarm relay is not activated. There is an option to transmit the fire drill report code to the Central Station. During a fire drill, the SILENCE key will silence all silenceable NACs and the RESET key restores the panel to normal. All zones remain active during a fire drill. MODE Pressing the Mode switch followed by a valid 4-digit numerical code and [ENTER/STORE] selects one of the six modes of operation. To enter Normal Mode from any other mode press MODE then 6676 [ENTER/STORE]. ☛ 6676 spells NORM on a Touch-Tone® phone. 1st EVENT The 1st Event switch along with the Up Arrow and Down Arrow keys, are used to display any presently active alarm and/or fault conditions present in the system. Press the 1st Event switch at any time to display the first event (alarm and/or trouble) that occurred. DOWN ARROW (ACK) Use the Down Arrow key to view other events (older) that have occurred and are active (not yet cleared). It also acknowledges the event by silencing the local piezo sounder. 68 Document #50193 Rev.D 5/2/97 P/N 50193:D LED Display and Status LEDs UP ARROW (ACK) Use the Up Arrow key to view other events (newer) that have occurred and are active (not yet cleared). It also acknowledges the event by silencing the local piezo sounder. [ENTER/STORE] Refer to the individual mode descriptions in previous sections of this manual. In Normal Mode, this key is used after pressing the MODE key followed by a 4-digit mode code followed by the [ENTER/STORE] key. 4.2 LED Display and Status LEDs LED Display Four 7-Segment red LED characters provide visual annunciation of status, events and messages. A list of messages that may appear on the display in Normal Mode is shown below: d__1 Zone 1 Disabled F__9 Trouble Zone 9 d__2 Zone 2 Disabled F_10 Trouble Zone 10 d__3 Zone 3 Disabled F_85 Annunciator Bus Fault d__4 Zone 4 Disabled F__A Annunciator Fault d__5 Zone 5 Disabled F__E Earth Fault d__6 Zone 6 Disabled F__P Printer Fault d__7 Zone 7 Disabled Lo_b Low Battery d__8 Zone 8 Disabled no_b No Battery d__9 Zone 9 Disabled PH_1 Primary C.S. No. Comm. Fault d_10 Zone 10 Disabled PH_2 Secondary C.S. No. Comm. Fault d_b1 NAC/Bell #1 Disabled bEL1 Bell 1 Fault d_b2 NAC/Bell #2 Disabled bEL2 Bell 2 Fault d_b3 NAC/Bell #3 Disabled bEL3 Bell 3 Fault d_b4 NAC/Bell #4 Disabled bEL4 Bell 4 Fault drLL Fire Drill no_1 Primary Phone Line Fault E__1 Zone 1 Enabled no_2 Secondary Phone Line Fault E__2 Zone 2 Enabled PA_1 Process Monitoring Alarm Zone 1 E__3 Zone 3 Enabled PA_2 Process Monitoring Alarm Zone 2 E__4 Zone 4 Enabled PA_3 Process Monitoring Alarm Zone 3 E__5 Zone 5 Enabled PA_4 Process Monitoring Alarm Zone 4 E__6 Zone 6 Enabled PA_5 Process Monitoring Alarm Zone 5 E__7 Zone 7 Enabled PA_6 Process Monitoring Alarm Zone 6 E__8 Zone 8 Enabled PA_7 Process Monitoring Alarm Zone 7 E__9 Zone 9 Enabled PA_8 Process Monitoring Alarm Zone 8 E_10 Zone 10 Enabled PA_9 Process Monitoring Alarm Zone 9 A__1 Alarm Zone 1 PA10 Process Monitoring Alarm Zone 10 A__2 Alarm Zone 2 SIL1 NAC/Bell #1 Silenced A__3 Alarm Zone 3 SIL2 NAC/Bell #2 Silenced A__4 Alarm Zone 4 SIL3 NAC/Bell #3 Silenced A__5 Alarm Zone 5 SIL4 NAC/Bell #4 Silenced A__6 Alarm Zone 6 SU_1 Supervisory Alarm Zone 1 A__7 Alarm Zone 7 SU_2 Supervisory Alarm Zone 2 A__8 Alarm Zone 8 SU_3 Supervisory Alarm Zone 3 A__9 Alarm Zone 9 SU_4 Supervisory Alarm Zone 4 A_10 Alarm Zone 10 SU_5 Supervisory Alarm Zone 5 F__1 Trouble Zone 1 SU_6 Supervisory Alarm Zone 6 F__2 Trouble Zone 2 SU_7 Supervisory Alarm Zone 7 F__3 Trouble Zone 3 SU_8 Supervisory Alarm Zone 8 F__4 Trouble Zone 4 SU_9 Supervisory Alarm Zone 9 F__5 Trouble Zone 5 SU10 Supervisory Alarm Zone 10 F__6 Trouble Zone 6 _AC_ AC Power Loss F__7 Trouble Zone 7 rES_ System Reset F__8 Trouble Zone 8 Document #50193 Rev. D 5/2/97 P/N 50193:D 69 LED Display and Status LEDs System Fire Alarm LED A red LED that flashes when a fire alarm condition is detected during the alarm presignal period. It turns on steady when the system silence or acknowledge switches are pressed. System Trouble LED A yellow LED that blinks to indicate that a fault or abnormal condition exists and that the fire alarm system may be inoperative. It turns on steady when a system silence or acknowledge switch is pressed. AC Power On LED A green LED that remains on while the AC power supply is within correct limits. If this indicator fails to light under normal conditions, service the system immediately. Supervisory LED A yellow LED that blinks to indicate the need for action in connection with the supervision or maintenance of sprinklers, extinguishing systems or other protective systems. System Silence LED A yellow LED that turns on to indicate that an Alarm or Trouble condition exists in the system, but Notification Appliance Circuits (if programmed as silenceable) and local piezo sounder have been silenced. Primary Line Active LED A red LED that indicates the primary phone line is active. Secondary Line Active LED A red LED that indicates the secondary phone line is active. Kiss-Off LED A green LED that blinks when a Central Station has acknowledged receipt of each transmitted message or when a portion of up or download data has been accepted from a Service Terminal. Modem LED A green LED that stays on steady during modem types of communications. FIGURE 4-2: Phone Connectors and LEDs Kissoff LED Primary Phone Line Primary Active LED Secondary Phone Line Secondary Active LED Modem LED 70 Document #50193 Rev.D 5/2/97 P/N 50193:D Operation 4.3 Operation Normal Mode is the standard mode of operation. In this mode, the panel continuously monitors system status. When no alarm or trouble conditions exist, the display will be blank and all LEDs will be off (except the AC Power LED). The Notification Appliance Circuits will be off, all relays are in their normal state, the onboard piezo sounder will be off and the printer (if connected) will not be printing. The Primary and Secondary Phone Line Active LEDs are off since the communicator is not active. All alarm and system trouble conditions are annunciated on the control panel's display. The control panel will maintain an 'active event list' which will consist of all alarms, supervisory alarms and system troubles currently active and not cleared, requiring immediate service. When the system is cleared and restored to normal, the display will be blank. All alarms and troubles are stored in a history file and may be recalled at any time. Higher priority events take precedence over lower priority events. Display and reporting of System Status is done on a priority basis. Priorities are, from highest to lowest: 1. Alarms 2. Supervisory Alarms 3. System Troubles 4. Process Monitoring Alarms If the events to be displayed consist of alarms and disabled zones only (no troubles), the control panel will scroll them on the display. As each new alarm occurs, it will be displayed immediately on the display for five seconds. After this five second period, the display will scroll all alarms in the system. Pressing the 1st Event key or one of the 'ACK' keys will stop the scrolling. The 1st Event key will also cause the display to show the First alarm that occurred after the panel was last reset, cleared of all active events and placed into normal mode. Operation of the Up and Down arrow keys will display all remaining events in sequence. If events to be displayed include system troubles, only one event is displayed at a time and there is no scrolling. The event displayed is the highest priority. Pressing the 1st Event key will cause the display of the first event that occurred after the panel was last reset, cleared of all active events and placed into normal mode. Operation of the Up and Down arrow keys will display all remaining events in order of their occurrences. 4.3.1 Fire Alarm Response The control panel will, upon detection of an alarm condition, cause the following: • • • • • • • • • • • • Blink the FACP alarm LED (1 second On, 1 second Off) Display the alarm message (i.e. A__1 Alarm on Zone 1) Communicate the alarm to the Central Station Store the alarm in the History File Turn the Notification Appliance Circuits on Turn the piezo sounder on steady Turn on appropriate zone relay output (ACM-8RF) Turn on any system relays (main circuit board) programmed for alarm activation Output alarm message to printer Terminate upload or download communications Blink all remote annunciator general alarm LEDs (1 second On, 1 second Off) Blink all remote annunciator zone alarm LEDs (1 second On, 1 second Off) Note that when any zone is programmed as a supervisory or process monitored zone, it will not be processed in the same manner as a conventional alarm zone. Refer to “System Supervisory Condition Response” on page 72 and “Process Monitored Alarm Response” on page 74 Document #50193 Rev. D 5/2/97 P/N 50193:D 71 Operation 4.3.2 Fire Alarm Restoral The control panel returns to normal after all alarms have been cleared and a system reset switch has been pressed (pull stations have been reset, smoke detectors have reset and no smoke is present, waterflow has stopped). The control panel will perform the following upon restoral of all active alarms: • • • • • • • • • • • Turn off the FACP alarm LED Clear the 4-character display Send all 'Zone Restoral' messages to the Central Station Turn off the Notification Appliance Circuits Turn off the piezo sounder Turn off appropriate zone relay output (ACM-8RF) Turn off any system relays (main circuit board) programmed for alarm activation Output alarm restoral message to printer Terminate upload or download communications Turn off all remote annunciator general alarm LEDs Turn off all remote annunciator zone alarm LEDs 4.3.3 System Supervisory Condition Response Program zones for Supervisory in applications where a waterflow sensing device has been employed and the wiring to the waterflow valve and/or a tamper switch is to be monitored. If the tamper switch has been activated (Normally Open contacts close), a supervisory alarm condition will occur. When a supervisory condition occurs, the control panel will cause the following: • • • • • • • • • • • Blink the FACP supervisory LED (½ second On, ½ second Off) Display the following message: SUXX (XX=Zone Number) Communicate the supervisory condition to the Central Station Store the 'supervisory' message in the History File Pulse system piezo sounders (½ second On, ½ second Off) Turn on appropriate zone relay output (ACM-8RF) Turn on any system relays (main circuit board) programmed for supervisory activation Output system supervisory message to printer Terminate upload or download communications Blink all remote annunciator general supervisory alarm LEDs (½ second On, ½ second Off) Blink all remote annunciator zone supervisory alarm LEDs (½ second On, ½ second Off) 4.3.4 System Supervisory Restoral Response When the supervisory condition has been cleared (condition is restored and the reset switch has been pressed), the control panel will perform the following: • • • • • • 72 Turn off the supervisory LED Clear the display of the 'SUXX' Communicate a supervisory restoral message to the Central Station Shut off system piezo sounders Turn off appropriate zone relay output (ACM-8RF) Turn off any system relays (main circuit board) programmed for supervisory activation Document #50193 Rev.D 5/2/97 P/N 50193:D Operation • • • • Output system supervisory restoral message to printer Terminate upload or download communications Turn off all remote annunciator general supervisory alarm LEDs Turn off all remote annunciator zone supervisory alarm LEDs Note that for any zone programmed for Supervisory autoresettable, the Reset key does not need to be pressed to clear the zone (supervisory condition). 4.3.5 Trouble Condition Response The control panel will perform the following upon detection of one or more trouble conditions: • • • • • Blink the FACP trouble LED (1 second On, 1 second Off) • • • • • Communicate the trouble conditions to the Central Station Blink all annunciator general system trouble LEDs Blink all affected zone trouble LEDs on all system annunciators Activate any FACP trouble relay(s) if programmed for trouble activation Display the appropriate trouble message(s) in priority fashion from the highest priority to the lowest. Note that the Up arrow key, Down arrow key or 1st Event key must be pressed to view the messages. Store the trouble conditions in the History File Sound system piezo sounders at a rate of 1 second On, 1 second Off Output the system trouble messages to the printer Terminate upload or download communications Note that when AC Brownout occurs, the AC LED is turned off and the Trouble LED blinks. Should the brownout condition remain, it will be transmitted to the Central Station after a delay (see Program Address 77 in the Level 1 Main Panel Options section). Possible trouble messages that may appear on the display are as follows: _AC_ d__1 d__2 d__3 d__4 d__5 d__6 d__7 d__8 d__9 d_10 F__1 F__2 F__3 F__4 F__5 F__6 F__7 F__8 F__9 AC Loss (shown only when requested) Zone 1 Disabled F__10 Trouble Zone 10 Zone 2 Disabled d_b1 Bell 1 Disabled Zone 3 Disabled d_b2 Bell 2 Disabled Zone 4 Disabled d_b3 Bell 3 Disabled Zone 5 Disabled d_b4 Bell 4 Disabled Zone 6 Disabled F__A Annunciator Fault Zone 7 Disabled F__P Printer Fault Zone 8 Disabled F__E Earth Fault Zone 9 Disabled Lo_b Low Battery Zone 10 Disabled no_b No Battery Trouble Zone 1 PH_1 Primary C.S. No. Comm. Fault Trouble Zone 2 PH_2 Secondary C.S. No. Comm. Fault Trouble Zone 3 bEL1 Bell 1 Fault Trouble Zone 4 bEL2 Bell 2 Fault Trouble Zone 5 bEL3 Bell 3 Fault Trouble Zone 6 bEL4 Bell 4 Fault Trouble Zone 7 no_1 Primary Phone Line Fault Trouble Zone 8 no_2 Secondary Phone Line Fault Trouble Zone 9 Document #50193 Rev. D 5/2/97 P/N 50193:D 73 Operation 4.3.6 Trouble Condition Restoral The control panel performs the following upon restoral of all trouble conditions: • • • • • • • • • The trouble LED is shut Off FACP trouble relay(s) deactivate if programmed for trouble activation If the trouble was loss of AC power, the control panel will turn on the AC LED upon restoral Clear the FACP display of trouble message(s) Communicate the restored trouble condition(s) to the Central Station Output the system trouble restoral message to the printer Terminate upload or download communications Turn off the system general trouble LED on all system annunciators if all trouble conditions are cleared Turn off all affected zone trouble LEDs on all system annunciators 4.3.7 Process Monitored Alarm Response Upon detection of a critical or noncritical process monitored alarm condition on any zone, the control panel will: • • • • • • • • • Display the alarm message PAXX (where XX = zone number) Communicate the alarm code programmed for the activated zone Store the alarm in the History File Pulse the piezo sounder at a ¼ second On, ¼ second Off Turn on appropriate zone relay output (ACM-8RF) Turn on any system relays (main circuit board) programmed for process alarm activation Output alarm message to printer Terminate upload or download communications Blink all remote annunciator zone alarm LEDs (¼ second On, ¼ second Off) 4.3.8 Process Monitored Alarm Restoral The control panel returns to normal after all alarms have been cleared and a system reset switch has been pressed (process monitored alarm devices reset). The control panel will perform the following upon restoral of all active process monitored alarms: • • • • • • • • • Clear the 4-character display Communicate the alarm restoral code programmed for the activated zone Store the alarm restoral message in the History File Turn off the piezo sounder Turn off appropriate zone relay output (ACM-8RF) Turn off any system relays (main circuit board) programmed for process alarm activation Output alarm restoral message to printer Terminate upload or download communications Turn off all remote annunciator zone alarm LEDs Note that for any zone programmed for autoresettable process monitored alarm, the reset key does not need to be pressed to clear the zone. 74 Document #50193 Rev.D 5/2/97 P/N 50193:D Operation 4.3.9 OFF Normal Reporting Removing the panel from Normal Mode and placing it into Troubleshoot, Walktest or Program Mode causes a transmission of an 'off normal' fault message. Returning the panel to Normal Mode causes a transmission of a 'return to normal' restoral message. 4.3.10 Zone Disable/Enable The zone disable feature may be used to disable any zone in the system. While in Normal Mode or Walktest Mode, zones may be disabled if they are normal, in trouble or alarmed. If the panel is in alarm, the silence switch must be pressed first before zone disable will function in Normal Mode. To disable a zone, press the MODE key once, (the display will go blank). You then have 10 seconds to start entering the code 3472. Next, press the [ENTER/STORE] key. ☛ 3472 spells DISA on a Touch-Tone® phone. A flashing lower case d will appear on the far left of the display. Next, press the zone number to be disabled. The number will appear on the far right display character. Press [ENTER/STORE]. The zone is disabled. All system annunciators will show zone troubles and general trouble status. Note that the trouble relay is activated and the trouble LED blinks. The zone disable message will remain on the display until the zone is reenabled. To reenable a zone, press the MODE key once (the display will go blank). You then have 10 seconds to start entering the code 3622. Next, press the [ENTER/STORE] key. ☛ 3622 spells ENAB on a Touch-Tone® phone. A flashing upper case E will appear on the left of the display. Next, press the zone number to be enabled. The number will appear on the far right display character. Press [ENTER/STORE]. The zone is reenabled. Note that the trouble relay is restored to normal and the FACP trouble LED is off and all system annunciator zone trouble LEDs are off. 4.3.11 NAC (bell) Disable/Enable The NAC/bell disable feature may be used to disable any of the four main panel NAC/bell circuits. While in Normal Mode, NACs may be disabled if they are normal, in trouble or alarmed. To disable an NAC/bell, press the MODE key once (the display will go blank). You then have 10 seconds to start entering the code 3472. Next, press the [ENTER/STORE] key. ☛ 3472 spells DISA on a Touch-Tone® phone. A flashing lower case d will appear on the far left of the display. Next, press the b key followed by the NAC number to be disabled. The b and the NAC number will appear on the far right display characters. Pressing [ENTER/ STORE] will disable the NAC. All system annunciators will show general trouble status and the main panel display will show the NAC disabled message, turn on the system trouble LED and activate relays programmed for system trouble. The NAC disable message will remain on the display until the circuit is reenabled. To reenable an NAC, press the MODE key once (the display will go blank). You then have 10 seconds to start entering the code 3622. Next, press the [ENTER/STORE] key. ☛ 3622 spells ENAB on a Touch-Tone® phone. A flashing upper case E will appear on the left of the display. Next, press the b key followed by the NAC number to be enabled. The b and the NAC number will appear on the far right display characters. Pressing [ENTER/STORE] will reenable the NAC. Note that relays programmed as trouble are restored to normal and the FACP trouble LED is off and all system annunciator general trouble LEDs are off. Document #50193 Rev. D 5/2/97 P/N 50193:D 75 Central Station Communications 4.3.12 Fire Drill The DRILL (manual evacuate) feature turns on all Notification Appliance Circuits (if programmed as enabled) and turns off the silence LED. To perform a fire drill, press the MODE key followed by the code 3745 then the [ENTER/ STORE] key. The display will read drLL. The alarm relay is not activated. There is an option to transmit the fire drill report code to the Central Station. ☛ 3745 spells dril on a Touch-Tone® phone. During a fire drill, the SILENCE key will silence the silenceable Notification Appliance Circuits and the RESET key restores the panel to normal. All zones remain active during a fire drill. 4.4 Central Station Communications The control panel transmits zone and system status reports to central stations via the public switched telephone network. Two supervised telephone line connections are made to interface the control panel to the telephone lines. Two 7-foot (2.13 m) telephone cords P/N MCBL-7 may be used for this purpose. The control panel supervises both telephone lines for proper voltage. A delay of two minutes will occur before a fault in either phone line connection is reported as a trouble. When a fault is detected, an audible trouble signal will sound, the yellow trouble LED will blink, the 4-character display will show either 'no_1' (primary phone line) or 'no_2' (secondary phone line), depending upon which telephone line has the fault, and the trouble condition will be reported to a central station over the remaining good phone line. The control panel comes with line seizure capability provided for both the primary and secondary telephone line interfaces. Any time that the control panel needs to make a call to a central station, line seizure will disconnect any local premises phones sharing the same telephone line. All transmissions to central stations will be sent over the Primary Central Station phone line. In the event of noisy phone lines, transmissions will be sent over the backup Secondary phone line. Two phone numbers must be programmed, the Primary Central Station phone number and the Secondary Central Station phone number. There are three options for transmission to the central station: • All messages are always sent to the Primary Central Station phone number with the Secondary Central Station phone number for emergency backup purposes only. • All reports are sent to both central station phone numbers. • Reports are sent to the first available central station phone number only. If 10 total attempts to communicate are unsuccessful, system relays programmed for Communications Failure will be activated. The FACP will also display 'PH1' for Communicator Failure to the Primary Central Station phone number or 'PH2' for Communicator Failure to the Secondary Central Station phone number. The MS-5210UD meets NFPA 72 National Fire Code reporting requirements for the type of signal, condition and location of the reporting premises. The general priority reporting structure is: 1. Zone Alarms and Restores 2. Zone Trouble and Restores 3. System Troubles and Restores 4. 24-hour test The control panel is capable of reporting detailed messages depending upon the format in use. Table 4-1 shows the reporting structure for all formats. 76 Document #50193 Rev.D 5/2/97 P/N 50193:D Central Station Communications TABLE 4-1: Format Selection Addresses (16+42) Programming Level 1 Format # 0, 2, 4, 6, 8 Format # 3, 5, 7, 9 Report 3+1/4+1/Standard 4+1 Express 3+1/4+1/Expanded Alarm SSS(S) A Alarm Restore SSS(S) RA Zone Trouble (Zone Open) SSS(S) TZ Format # 1, A, C 4+2/Standard 4+2 Express SSS(S) A AAA(A) Z SSS(S) RA RARARA(RA) Z SSS(S) TZ TZTZTZ(TZ) Z SSS(S) RTZ Format # B, D 4+2/Expanded SSSS AA2 SSSS AZ SSSS RARA2 SSSS RAZ SSSS TZTZ2 SSSS TZZ SSSS RTZRTZ2 SSSS RTZZ SSSS TSTS2 SSSS TSY SSSS RTSRTS2 SSSS RTSY SSSS DZDZ2 SSSS DZZ SSSS RDZRDZ2 SSSS RDZZ Zone Trouble Restore SSS(S) RTZ System Trouble SSS(S) TS System Trouble Restore SSS(S) RTS Zone Disable SSS(S) DZ Zone Disable Restore SSS(S) RDZ Bell Disable SSS(S) DB SSS(S) DB SSSS DBDB2 SSSS DBDB2 Bell Disable Restore SSS(S) RB SSS(S) RB SSSS RBRB2 SSSS RBRB2 RTZRTZRTZ(RTZ) Z SSS(S) TS TSTSTS(TS) Y SSS(S) RTS RTSRTSRTS(RTS) Y SSS(S) DZ DZDZDZ(DZ) Z SSS(S) RDZ RDZRDZRDZ(RDZ) Z Low Battery SSS(S) L SSS(S) L SSSS LL2 SSSS LL2 Low Battery Restore SSS(S) RL SSS(S) RL SSSS RLRL2 SSSS RLRL2 No Battery SSS(S) N SSS(S) N SSSS NN2 SSSS NN2 No Battery Restore SSS(S) RN SSS(S) RN SSSS RNRN2 SSSS RNRN2 AC Loss SSS(S) P SSS(S) P SSSS PP2 SSSS PP2 AC Loss Restore SSS(S) RP SSS(S) RP SSSS RPRP2 SSSS RPRP2 Fire Drill SSS(S) Fd SSS(S) Fd SSSS FdFd2 SSSS FdFd2 Fire Drill Restore SSS(S) RFd SSS(S) RFd SSSS RFdRFd2 SSSS RFdRFd2 Supervisory Condition SSS(S) V SSSS VV2 SSSS VZ Supervisory Condition Restore SSS(S) RV SSSS RVRV2 SSSS RVZ SSS(S) V VVV(V) Z SSS(S) RV RVRVRV(RV) Z Test Report SSS(S) X SSS(S) X SSSS XX2 SSSS XX2 Up or Download SSS(S) UD SSS(S) UD SSS UDUD2 SSS UDUD2 Refer to Table 4-2 for an explanation of each letter code in Table 4-1 . Refer to Table 4-3 for a list of compatible receivers. Document #50193 Rev. D 5/2/97 P/N 50193:D 77 Central Station Communications TABLE 4-2: Where: SSS or SSSS A A2 Z RA RA2 TZ TZ2 RTZ RTZ2 TS TS2 RTS RTS2 DZ DZ2 RDZ RDZ2 DB DB2 RB RB2 L L2 RL RL2 N N2 RN RN2 P P2 RP RP2 FD FD2 RFD RFD2 V V2 RV RV2 X X2 Y UD UD2 Format Selection Address Explanation = Subscriber ID = Alarm (1st digit) = Alarm (2nd digit) = Zone Number = Alarm Restore (1st digit) = Alarm Restore (2nd digit) = Zone Trouble (1st digit) = Zone Trouble (2nd digit) = Zone Trouble Restore (1st digit) = Zone Trouble Restore (2nd digit) = System Trouble (1st digit) = System Trouble (2nd digit) = System Trouble Restore (1st digit) = System Trouble Restore (2nd digit) = Zone Disable (1st digit) = Zone Disable (2nd digit) = Zone Disable Restore (1st digit) = Zone Disable Restore (2nd digit) = Bell Disable (1st digit) = Bell Disable (2nd digit) = Bell Disable Restore (1st digit) = Bell Disable Restore (2nd digit) = Low Battery (1st digit) = Low Battery (2nd digit) = Low Battery Restore (1st digit) = Low Battery Restore (2nd digit) = No Battery (1st digit) = No Battery (2nd digit) = No Battery Restore (1st digit) = No Battery Restore (2nd digit) = AC Loss (1st digit) = AC Loss (2nd digit) = AC Loss Restore (1st digit) = AC Loss Restore (2nd digit) = Fire Drill (1st digit) = Fire Drill (2nd digit) = Fire Drill Restore (1st digit) = Fire Drill Restore (2nd digit) = Supervisory Condition (1st digit) = Supervisory Condition (2nd digit) = Supervisory Condition Restore (1st digit) = Supervisory Condition Restore (2nd digit) = Test Report (1st digit) = Test Report (2nd digit) = A Trouble corresponding to the following: 1 = Earth Fault 2 = Not Used 3 = Not Used 4 = Telco Primary Line Fault 5 = Telco Secondary Line Fault 6 = NAC #1 Fault 7 = NAC #2 Fault 8 = NAC #3 Fault 9 = NAC #4 Fault A = Communication Failure to Primary Number B = Communication Failure to Secondary Number C = Printer Fault D = Annunciator Fault E = 485 Communication Failure F = System Off Normal = Upload/Download (1st digit) = Upload/Download (2nd digit) Note that for Expanded Reporting, the control panel automatically adds the digit corresponding to the zone number, and the second digit corresponding to any system trouble condition. Only the first digit is programmable. 78 Document #50193 Rev.D 5/2/97 P/N 50193:D Central Station Communications 4.4.1 Transmittal Priorities The integral communicator transmits highest priority events first. Events in terms of priority are listed below in descending order: 1. Alarms (Highest Priority Level) Pull Stations Waterflow Smoke Detector Other Alarm Types 2. Supervisory Zone 3. System Troubles Zone/NAC Disabled Fire Drill AC Fail (after delay) Zonal faults Earth fault Low battery/No battery Telephone line fault Notification Appliance Circuits fault Communication Trouble Printer Trouble Annunciator Trouble EIA-485 fault System Off Normal Process Monitoring Alarm 4. Restoral Reports Zone Alarm Supervisory Zone(s) enabled Fire Drill AC Zone fault Earth Battery Telephone Line Notification Appliance Circuits Communication Printer Annunciator EIA-485 System Off Normal Process Monitoring Restored 5. System Test (Lowest Priority) Red LEDs are provided on the control panel circuit board to identify which telephone line is activated. Also, a green LED labeled 'Kissoff', will turn on whenever the control panel has successfully transmitted reports to the Central Station. The 'Kissoff' LED may turn on several times during communications with a central station. Document #50193 Rev. D 5/2/97 P/N 50193:D 79 Central Station Communications The following table contains UL listed receivers compatible with the MS-5210UD. 0 4+1 Ademco Express ✔ ✔ 1 4+2 Ademco Express ✔ ✔ ✔(8) 2 3+1/Standard/1800/2300 ✔ ✔ ✔ ✔(4) ✔ 3 3+1/Expanded/1800/2300 ✔ ✔ ✔ ✔(4) 4 3+1/Standard/1900/1400 ✔ ✔ 5 3+1/Expanded/1900/1400 ✔ ✔ 6 4+1/Standard/1800/2300 ✔ ✔ 7 4+1/Expanded/1800/2300 ✔ 8 4+1/Standard/1900/1400 9 Surguard MLR-2 (9) Sescoa 3000R (7) Radionics 6000/6500 (5) Osborne Hoffman Models 1 & 2 FBI CP220FB ITI CS-4000 (3) Format # (Addresses 16 & 42) Silent Knight 9000 (2) Compatible UL Listed Receivers Ademco 685(1) TABLE 4-3: ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔(4) ✔ ✔ ✔ ✔(4) ✔ ✔ ✔ ✔(4) ✔ ✔ ✔ ✔ ✔(4) ✔ ✔ ✔ ✔ ✔ ✔(4) ✔ ✔ ✔ 4+1/Expanded/1900/1400 ✔ ✔ ✔(4) ✔ ✔ ✔ A 4+2/Standard/1800/2300 ✔ ✔ ✔(4) ✔ ✔ ✔ B 4+2/Expanded/1800/2300 ✔ ✔ ✔(4) ✔ ✔ ✔ C 4+2/Standard/1900/1400 ✔ ✔ ✔(4) ✔ ✔ ✔ D 4+2/Expanded/1900/1400 ✔ ✔ ✔(4) ✔ ✔ ✔ E Ademco Contact ID ✔ ✔ ✔ ✔ ✔ ✔(5, 6) ✔(5) ✔(5) ✔ (1) With 685-8 Line Card with Rev 4.4d software. (2) With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. (3) Rev. 4.0 software. (4) FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. (5) Model 6500 with Rev 600 software. (6) Model 6000 with Rev 204 software. (7) With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. (8) Model 2 only. (9) Version 1.62 software. 80 Document #50193 Rev.D 5/2/97 P/N 50193:D Servicing CHAPTER 5 5.1 Servicing Walk Test Mode The MS-5210UD provides the capability to perform a one-man walktest of the system without triggering the communicator, the ACM-8RF zone relays, the system annunciators or the alarm output relay. Walk Test Mode allows for testing of the 10 zones (initiating device circuits). Zones defined as Reset, Acknowledge, Silence, Drill, Autoresettable Process Monitoring or Process Monitoring are not part of the one-man walktest function. Zones defined as Pull Station, Normally-Open Contact, two or four-wire smoke detector, waterflow or supervisory are functionally tested in Walk Test Mode. An audible or silent walktest may be performed. For an audible walktest, the first initiating device activated on a zone will cause the Notification Appliance Circuits to turn on for four seconds. Subsequent device activations on the same zone will cause the Notification Appliance Circuits to turn on for one second. Any smoke detectors that are activated will be reset. Zonal faults (open circuits) will cause the NAC to remain on steadily. Prior to entering Walk Test Mode, check to be certain that all system faults have been cleared. Note that trouble relays will be activated while the control panel is in Walk Test Mode. Placing the control panel into Walk Test Mode will only be possible if the system has no active alarms. Pressing the MODE key followed by the 4-digit code 9255 and then pressing the [ENTER/STORE] key will place the control panel into Walk Test Mode. ☛ 9255 spells WALK on a Touch-Tone® phone. An S will be displayed on the left most character and a flashing 0 on the far right character. For audible walktest, press the [ENTER/STORE] key. For silent walktest, press the 1 key followed by the [ENTER/STORE] key. Once in Walk Test Mode, the control panel will immediately: • Blink the trouble LED • Activate the trouble relay • If an audible walktest is performed, the MS-5210UD will turn on the Notification Appliance Circuits for four seconds for the first alarm on a zone. Subsequent alarms will sound for one second. Troubles cause the NACs to remain on. For a silent walktest, all NAC outputs remain off. • • • • • • Disable the alarm relay Display all alarm conditions as they occur. Display all zone troubles as they occur. Display all system troubles as they occur Transmit 'off normal' message to Central Station(s) Continue to communicate any events not acknowledged at a central station prior to entering Walk Test Mode During Walk Test Mode, zonal activity is displayed in real time as it occurs. At the end of walktesting the system, the display will show the last event that occurred. To view all events stored during walktest, use the Up arrow, Down arrow and 1st Event keys. The Down arrow key moves the walktest list to show older (previous) events. The Up arrow key moves the walktest list to show newer (more recent) events. Pressing the 1st Event key at any time will cause the display of the first event stored upon initial entry into Walk Test Mode. While in Walk Test Mode, the control panel will store up to 256 events in the Walk Test File for later recall and display. A printer may be connected to the panel during walktest. All walktest events are printed in real-time as they occur. Document #50193 Rev. D 5/2/97 P/N 50193:D 81 History Mode Zone disable mode may be used while in Walk Test Mode. Should a faulty device require repair, the zone may be disabled while the repair is performed. This allows the user to return the system to Normal Mode, enabling all other zones. This also prevents triggering of a false alarm. To return the control panel to Normal Mode, press the MODE key followed by the 4- digit code 6676 and then the [ENTER/STORE] key. To go to any other mode, press the MODE key followed by the appropriate 4-digit code and then the [ENTER/STORE] key. To go from silent walktest to audible walktest (or vice versa), press the MODE key followed by the [ENTER/STORE] key. S__0 or S__1 will appear in the display. Simply alter the '0' or '1' entry then press the [ENTER/STORE] key. Any delay between key entries greater than 10 seconds causes the control panel to remain in Walk Test Mode. The control panel will automatically revert back to Normal Mode if no system activity has occurred for 60 minutes. This would include pressing any keys or activity on any zone. Exiting Walk Test Mode leaves the Walk Test file in memory such that it may be printed in Print Mode. Subsequent entries into Walk Test Mode will delete the Walk Test file. During an audible walktest, if a device remains latched in alarm (such as a Pull Station that is not reset after activation), subsequent testing of devices on the same zone will not trigger the NACs. Be certain to reset or clear each device after testing. Note that remote site upload or download is possible when the system is in Walk Test Mode. 5.2 History Mode All Normal Mode events are stored in a History File list for future recall. Recall is possible via the 4-character display or via an optional printer. See the following page for a list and description of each event displayed. This History File list is a first-in, first-out (FIFO) buffer. Only the most recent events may be called up from memory. Old events will be overwritten, i.e. pushed out of the FIFO. The number of stored events is 256. The History File is kept in E2 memory. Complete power loss will not erase the list. Pressing the MODE key followed by the 4-digit code 4478 and then the [ENTER/STORE] key places the control panel into History Mode. The most recent event will be displayed. This will not occur if there are any active alarm conditions present. The fire protection remains active in History Mode. If an alarm occurs, the panel will automatically exit History Mode. ☛ 4478 spells HIST on a Touch-Tone® phone. Once in History Mode, the control panel will: • Display all events as they occurred since the last time the History File list was cleared (the most recent event being displayed first) • Ignore all keys except those mentioned in this section • Continue to communicate any events not previously acknowledged at the Central Station prior to entering History Mode. The Down arrow key moves the History File to show older (previous) events. The Up arrow key moves the History File to show newer (most recent) events. 82 Document #50193 Rev.D 5/2/97 P/N 50193:D History Mode Shown below is the list of messages as they will appear on the display: TABLE 5-1: DISPLAY ACn_ A__! A__2 A__3 A__4 A__5 A__6 A__7 A__8 A__9 A_10 SU_1 SU_2 SU_3 SU_4 SU_5 SU_6 SU_7 SU_8 SU_9 SU10 PA_1 PA_2 PA_3 PA_4 PA_5 PA_6 PA_7 PA_8 PA_9 PA10 _AC_ F__1 F__2 F__3 F__4 F__5 F__6 F__7 F__8 F__9 F_10 bEL1 bEL2 bEL3 bEL4 History Mode Messages EVENT Acknowledge key pressed Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Zone 9 Alarm Zone 10 Alarm Supervisory 1 Alarm Supervisory 2 Alarm Supervisory 3 Alarm Supervisory 4 Alarm Supervisory 5 Alarm Supervisory 6 Alarm Supervisory 7 Alarm Supervisory 8 Alarm Supervisory 9 Alarm Supervisory 10 Alarm Process Alarm Zone 1 Process Alarm Zone 2 Process Alarm Zone 3 Process Alarm Zone 4 Process Alarm Zone 5 Process Alarm Zone 6 Process Alarm Zone 7 Process Alarm Zone 8 Process Alarm Zone 9 Process Alarm Zone 10 AC Loss Zone 1 Fault Zone 2 Fault Zone 3 Fault Zone 4 Fault Zone 5 Fault Zone 6 Fault Zone 7 Fault Zone 8 Fault Zone 9 Fault Zone 10 Fault Bell 1 Fault (open or short) Bell 2 Fault (open or short) Bell 3 Fault (open or short) Bell 4 Fault (open or short) DISPLAY F__E F__A F__P F_85 d__1 d__2 d__3 d__4 d__5 d__6 d__7 d__8 d__9 d_10 drLL E__1 E__2 E__3 E__4 E__5 E__6 E__7 E__8 E__9 E_10 d_b1 d_b2 d_b3 d_b4 E_b1 E_b2 E_b3 E_b4 PH_1 PH_2 no_b Lo_b SILE SIL1 SIL2 SIL3 SIL4 no_1 no_2 rES_ POr_ EVENT Earth Fault Annunciator Fault Printer Fault Annunciator Bus Fault Zone 1 disabled Zone 2 disabled Zone 3 disabled Zone 4 disabled Zone 5 disabled Zone 6 disabled Zone 7 disabled Zone 8 disabled Zone 9 disabled Zone 10 disabled Fire Drill Enable Zone 1 Enable Zone 2 Enable Zone 3 Enable Zone 4 Enable Zone 5 Enable Zone 6 Enable Zone 7 Enable Zone 8 Enable Zone 9 Enable Zone 10 Disable bell 1 Disable bell 2 Disable bell 3 Disable bell 4 Enable bell 1 Enable bell 2 Enable bell 3 Enable bell 4 Primary C.S. Number Communication Fault Secondary C.S. Number Communication Fault No Battery Low Battery Silence Switch Pressed NAC/Bell #1 Silenced NAC/Bell #2 Silenced NAC/Bell #3 Silenced NAC/Bell #4 Silenced Primary Phone Line Fault Secondary Phone Line Fault Reset Switch Pressed Power On Reset (unit was powered off completely, i.e. no AC and no battery) To erase the list from E2 memory, press the SILENCE key twice before exiting the History Mode. A lack of keyboard activity for a period of 10 minutes will cause the control panel to return to Normal Mode. If a printer is connected to the panel, the History File will be printed upon successful entry into History Mode and a list of the most recent 256 events, time and date stamped, will print out. Note that remote site upload or download is possible when the system is in History Mode. Document #50193 Rev. D 5/2/97 P/N 50193:D 83 Troubleshoot Mode 5.3 Troubleshoot Mode In this mode, system voltages may be displayed on the 4-character display. An internal voltmeter measures the voltage present at: ✓ zone inputs ✓ AC power input ✓ battery terminal leads ✓ NAC #1 ✓ NAC #2 ✓ NAC #3 ✓ NAC #4 ✓ Resettable 24 volt power A lack of keyboard activity for a period of 20 minutes will cause the control panel to return to Normal Mode. To enter the Troubleshoot Mode, press the MODE key followed by the 4-digit code 8768 and then the [ENTER/ STORE] key. ☛ 8768 spells TROU on a Touch-Tone® phone. Once in Troubleshoot Mode, the control panel will: • • • • • • • • Blink the FACP trouble LED Blink all remote annunciator LEDs Activate the FACP trouble relays if programmed for trouble operation Disable the Notification Appliance Circuits Output all troubleshoot voltage readings to external printer Disable the alarm relay Transmit the 'off normal' message to the Central Station(s) Continue to communicate any events not yet acknowledged at the Central Station prior to entering Troubleshoot Mode. The Up arrow, Down arrow and 1st Event keys do not function in Troubleshoot Mode. 5.3.1 Zones Pressing 01 through 10, followed by [ENTER/STORE], displays the zone voltage of the selected zone. Listed below are the nominal threshold voltages for each zone: Zone # Normal w/EOL Shorted Open Circuit 1 through 10 23.5V 0.00V 25.4V Readings will vary proportionately, depending upon system load and AC line voltage. 84 Document #50193 Rev.D 5/2/97 P/N 50193:D Troubleshoot Mode 5.3.2 AC Line Pressing A, followed by [ENTER/STORE], displays the AC input voltage as shown below. The AC ON indicator will turn off when the AC line voltage drops below the Low Line threshold, and the trouble LED will turn on. Following is a list of the AC line voltage range: AC Line Voltage Low Line Normal High Line MS-5210UD: 102 VAC 115 VAC 132 VAC MS-5210UDE: 204 VAC 220 VAC 264 VAC 5.3.3 Battery Pressing B, followed by [ENTER/STORE], will display the Battery Voltage. Listed below are the critical battery threshold conditions: Battery Voltage: Normal Low Battery No Battery 27.6V 20.4V <17.4V Note that voltage readings should be taken after allowing 48 hours to charge depleted batteries. If batteries do not show normal readings, replace them. 5.3.4 Telephone Lines Pressing C for touchtone dialing or D for rotary dialing, followed by the [ENTER/STORE] key, causes seizure of the Primary phone line, which in turn lights the red LED, signifying Primary phone line active. After a delay of three seconds, the control panel goes off-hook to acquire a dial tone. The control panel keypad may be used as a telephone touchpad for number dialing. Once the first digit is pressed, the display will move the C or D character one position to the left, while placing the digit to be dialed on the farthest right display position. Continue to press the phone numbers to be dialed. Successive depressions of the [ENTER/STORE] key hangs up and picks up the phone (places the phone on or off the hook). The secondary phone line may be tested by pressing the E key for touchtone dialing or the F key for rotary dialing and then following the same procedure used for the primary phone line. A handset may be temporarily connected across transformer T1 as illustrated in Figure 5-1. The handset, when connected across T1, may be used only as an amplifier/speaker and telephone with the control panel used for number dialing. Note that remote site upload or download is not possible while testing the phone lines in this portion of Troubleshoot Mode. FIGURE 5-1: Handset/Speaker Connection Both Primary and Secondary Lines Document #50193 Rev. D 5/2/97 P/N 50193:D 85 Lamp Test 5.3.5 NACs 1, 2, 3 and 4 • • • • Pressing B1, followed by [ENTER/STORE], displays the voltage on NAC #1. Pressing B2, followed by [ENTER/STORE], displays the voltage on NAC #2. Pressing B3, followed by [ENTER/STORE], displays the voltage on NAC #3. Pressing B4, followed by [ENTER/STORE], displays the voltage on NAC #4. NAC voltage readings are nominally -2.32 volts when an EOL resistor of correct value is in place. A reading of 0.00 volts will appear for a shorted output, -4.50 volts for an open output. Intermediate readings are also possible. 5.3.6 Resettable Power Pressing the RESET key, followed by [ENTER/STORE], displays the resettable 24 volt power. Resettable 24 volt power must read 24 volts, + or - 10%. 5.4 Lamp Test To perform a Lamp Test, press the MODE key followed by the 4-digit code 5267 and then the [ENTER/STORE] key. This will test all system LEDs on the FACP. The LEDs will stay on for five seconds, then the control panel will return to Normal Mode. ☛ 5.5 5267 spells LAMP on a Touch-Tone® phone. Print Mode Refer to Figure 2-13, “Remote Printer Connections,” on page 32 for proper PRT-24 Interface module connection to the main circuit board before proceeding. A printer may be temporarily or permanently connected to the panel. Program address '4' in Program Mode Level 3 to a '1' to enable printer supervision. Once enabled, normal system status as well as panel operations will be printed. If the printer connection is removed, the system trouble LEDs will blink, the system piezo sounders will pulse and the 4-character system LED display will read F__P. Select Printer Mode by pressing the MODE key followed by the code 7746 then pressing the [ENTER/STORE] key. The display will read Prn and the following time and date stamped data will be printed: ✓ Entire program entries ✓ History File ✓ Walktest File ✓ Troubleshoot Mode voltages ✓ Current System Status The fire protection remains active while in print mode. Remote site upload or download is allowed while in Print Mode. An alarm on any zone will take priority, causing the panel to exit Print Mode. 86 Document #50193 Rev.D 5/2/97 P/N 50193:D Printer Output 5.6 Printer Output This section illustrates sample printouts for various panel modes. Real Time Status 06-26-96 14:15:10 Zone 1 Verifying 2-Wire Smoke Detector Active 06-26-1996 Zone 2 2-Wire Smoke Detector Active 06-26-1996 Zone 2 Pull Station Active 06-26-1996 Zone 3 N.O. Contact Device Active 06-26-1996 Zone 4 Supervisory Active 06-26-1996 Zone 5 Waterflow, Silenceable Active 06-26-1996 Zone 6 Process Monitoring Active 06-26-1996 System Silenced 06-26-1996 NAC 1 Silence 06-26-1996 NAC 2 Silence 06-26-1996 Zone 1 Alarm Cleared 06-26-1996 Low Battery Detected 06-26-1996 Normal Battery 06-26-1996 Loss of AC Power 06-26-1996 AC Power Restore 06-26-1996 Drill Mode Entered 06-26-1996 System Reset 06-26-1996 Drill Mode Cleared 06-26-1996 Entering Walktest Mode 06-26-96 Zone 2 Pull Station Active 14:15:20 14:15:24 14:15:29 14:15:34 14:15:37 14:15:45 14:15:49 14:15:53 14:15:56 14:15:59 14:16:03 14:16:09 14:16:15 14:16:19 14:16:42 14:16:51 14:17:25 14:17:33 14:32:15 06-26-1996 14:33:20 Entering Trouble Shoot Mode 06-26-1996 14:47:12 Trouble Shoot Mode Data 06-26-96 14:47:12 Zone 1 Voltage =25.20 Zone 2 Voltage =25.18 Zone 3 Voltage =25.20 Zone 4 Voltage =25.20 Zone 5 Voltage =25.18 Zone 6 Voltage =25.18 Zone 7 Voltage =25.18 Zone 8 Voltage =25.20 Zone 9 Voltage =25.20 Zone 10 Voltage =25.20 AC Line Voltage =120.9 Battery Voltage =27.20 NAC 1 Voltage =-2.09 NAC 2 Voltage =-2.29 Resettable 24 Volts =26.03 Entering Lamp Test Mode 06-26-96 15:03:10 Entering Program Mode 06-26-96 15:08:13 Document #50193 Rev. D 5/2/97 P/N 50193:D 87 Remote Site Upload/Download CHAPTER 6 Remote Site Upload/Download The control panel may be programmed or interrogated off site via the public switched telephone network. Any personal computer with Windows® 3.1 or greater or Windows® 95, with a 1200 Baud Hayes™ compatible modem and Fire•Lite Upload/Download software P/N PK-5210UD, may serve as a Service Terminal. For details on the remote site upload/download software package, refer to the PK-5210UD manual. The Upload/Download software allows the following: • • • • • • • • ! Download of the entire program Download of an individual program item at Levels 1 - 4 Upload of the entire program Upload of an individual program item at Levels 1 - 4 Download of a single program item (such as a Central Station phone number) Upload of the entire program plus History File, Walktest data, current status, system voltages or time & date Real-time upload, either continuous or 'snapshot' (one-time), of current status or system voltages Execution of control panel functions: Trouble Silence, Manual Evacuate, Manual Evacuate Restore, Zone/ NAC Disable, Zone/NAC Enable and Set Time & Date CAUTION: Changes to program entries occur as a result of the downloading process. After successful downloading, make certain to perform the following steps: 1. Print out all programmed data via Print Mode or manually view programmed entries and compare to intended program data. 2. Test all affected panel operations. 3. Immediately correct any problems found. 6.1 Downloading Program: General Any time that the control panel is downloaded, whether initiated at the jobsite or remotely, a secret code (factory default 0000) is verified between the control panel and the Service Terminal. Changing the Secret Code may only be accomplished at the Service Terminal and subsequently loaded into the control panel. Future upload or download requests cause verification of the Secret Code by the control panel before processing of data is allowed. If the Secret Code is not verified, the control panel will terminate the request immediately. While the control panel is communicating with the Service Terminal, the panel's green Modem LED and one of the red Line Seize LEDs will remain on steady. At the conclusion of a successful download transaction, the green 'Kissoff' LED will come on steady for one second. Upon termination of communication, the green Modem LED will turn off and the red Line Seize LED will turn off. In order to download the panel (whether initiated at the jobsite or remotely) the following must be true: ✓ The control panel may be in any mode of operation including Normal, Program, History, Walk Test, Print, Troubleshoot or Lamp Test. It is also possible during any of the function modes including Disable, Enable and Drill. Downloading is not possible if the communicator is active during Central Station communications or while testing the phone lines while in Troubleshoot Mode. ✓ There cannot be any active communications ongoing with a Central Station receiver. ✓ All active events must be successfully 'Kissed-off' by the Central Station(s). The Communicator must be in a standby state with no new information waiting to be transmitted to a central station. Two basic communication mechanisms are supported as follows: 88 Document #50193 Rev.D 5/2/97 P/N 50193:D Downloading Program: General • Download with callback - The Service Terminal calls the control panel. The control panel answers the call, confirms the calling party then hangs up. The Service Terminal then waits for a callback from the control panel. After the control panel calls the Central Station and successfully reports that a request for downloading has been received, the control panel calls the Service Terminal back. Upon secret code verification, data transfers occur. When the data transfers are completed and the Service Terminal disconnects from the control panel, the panel calls the Central Station back to confirm either successful or nonsuccessful results. • Download with callback disabled - The Service Terminal calls the control panel. No hang-up sequence occurs. Data transfers proceed. Note that Callback enable/disable is controlled by the master user at the Service Terminal on a per call basis. With program address location 56 set to '1' in Program Mode Level 1, anytime a download with callback is initiated, the first thing the control panel will do is one of the following: • contact the primary Central Station • contact both the primary and secondary Central Stations • contact the first available Central Station phone number Once contact has been established, the control panel will report a 'request for upload/download' message (depending upon the program entry in Program Level 4 address location 42). Following 'kissoff' of the request by the Central Station(s), the control panel will then call the appropriate Service Terminal and begin the downloading process. With program address location 56 set to '1' in Program Mode Level 1, anytime a download with callback disabled is initiated, the control panel and the Service Terminal will communicate and transfer data without first contacting a Central Station. When the data transfers are completed and the control panel disconnects from the Service Terminal, the control panel will call the Central Station and report one of the following conditions: • Upload/download request received • Upload and/or download successful • Upload/download failed To prevent the 'request for up/download' message(s) from being reported to the Central Station(s), make certain to leave address 56 = 0 or disable all upload/download reports back to both Central Stations. Refer to Table 3-3 through Table 3-8 for additional information. During the downloading process, the fire protection remains active. Should a system trouble or alarm condition occur, the control panel immediately terminates downloading and processes the trouble or alarm locally and transmits the information to the Central Station(s). 6.1.1 Security Features Remote site upload and download with the control panel has been carefully designed to include key security features to ensure proper functionality. The key features are listed and explained below. Secret Code Verification A secret code is stored in the control panel by a Service Terminal to prevent unauthorized access. The secret code is created at the Service Terminal by a Master user and cannot be viewed or changed by anyone other than a Master user. Viewing of the secret code is prohibited at the control panel. Prior to allowing an upload or download of data, the control panel will verify the secret code transmitted by the Service Terminal. Time-out at Control Panel Upon answering an incoming call on either the primary or secondary Central Station phone line, the panel will listen for a modem connection signal. If this signal is not received within 30 seconds, the panel will disconnect the call. Document #50193 Rev. D 5/2/97 P/N 50193:D 89 Downloading Initiated at Control Panel Upon successful connection (i.e. secret code verified and callback completed, if applicable), if no communication occurs within two minutes, the panel will disconnect the call. Callback to Service Terminal Anytime that the panel is remotely requested to allow an upload or download with callback, it will confirm the source of the incoming call, hang-up and call the calling party (Service Terminal phone number) back. Panel Identification Number (future) The panel identification number will be used in the future to identify the panel to the Service Terminal (when the panel calls the Service Terminal) automatically. Calls initiated at the FACP must be coordinated at the Service Terminal manually. Note that the Service Terminal will not pickup the incoming call unless operating on the communications screen. The Service Terminal will not recognize an FACP initiated call unless the secret code is at the factory default settings. Error Checking As each block of data is received by the control panel, it is checked for accuracy. If an error is detected, the block is retransmitted until correct, up to a maximum of four times. If the Secret Code is not verified and four errors occur, the call is disconnected and the report that the upload/download was not successful is called to the Central Station(s). Central Station Acknowledge There is an option whereby the control panel will report to one or both Central Station(s) that a request for uploading or downloading has been received prior to processing the call. This is called the 'callback' option. If the Central Station(s) does not acknowledge receipt of this request, up or downloading is prohibited. If acknowledged by the Central Station(s), another message is transmitted informing the Central Station(s) of one of the following: • downloading was successful • uploading was successful • uploading/downloading was not successful Data Protection/Integrity Options allow programming of single data entries, single programming levels (1 - 4) and the entire programming of all four levels simultaneously. Use caution when selecting programming choices and verify all entries via an upload or manual check at the FACP. Data blocks containing user programming options are protected from partial programming due to faulty phone connections, line noise and other errors. 6.2 Downloading Initiated at Control Panel Before initiating the Download procedure, make certain that the following conditions exist: ✓ control panel is in Normal Mode ✓ Central Station communications are off or Main Panel Options programming location 56 = 0 ✓ the communicator is in the standby state (red Line Seize, green Modem and green Kissoff LEDs are off) Place the control panel into Program Mode and program one or both of the Service Terminal phone numbers. It is also advisable at this time to coordinate this call with the Service Terminal operator to allow the Service Terminal operator to easily identify the incoming call. Exit the Program Mode and return the control panel to Normal Mode. Press the MODE key followed by the 4-digit code 3696 and then the [ENTER/STORE] key. ☛ 90 3696 spells DOWN on a Touch-Tone® phone. Document #50193 Rev.D 5/2/97 P/N 50193:D Downloading Initiated at a Service Terminal The display to the far left will flash the letter S. Press the digit '1' for Service Terminal phone #1 or '2' for Service Terminal phone #2, followed by the [ENTER/STORE] key. The control panel will now call the appropriate Service Terminal phone number. With the Service Terminal set up with the correct download customer file and operating in the communications window, the downloading process may begin. Once the called Service Terminal accepts the incoming call (control panel) and verifies the secret code, the downloading process is allowed to continue. Downloading progresses until all programmed information has been successfully loaded into the control panel. Communication terminates upon the Service Terminal hanging up or upon the FACP hanging up after a two minute time-out following completion of data transfer. 6.3 Downloading Initiated at a Service Terminal Before initiating the Download procedure, make certain that the communicator is in the standby state; red Line Seize, green Modem and green Kissoff LEDs are off. Once an incoming call is accepted/answered by the control panel, the panel will: 1. Establish basic modem connection 2. Verify secret code 3. Verify callback vs. no callback request from the Service Terminal (if callback is requested, panel will perform steps 4 through 10; if no callback is requested, panel will perform only steps 9 and 10) 4. Identify the Service Terminal location 5. Hang-up/disconnect call 6. Call the Central Station(s) and transmit a request for upload/download message (if programmed to do so). If this message is accepted, the control panel will proceed to the next step 7. Return call to Service Terminal 8. Verify secret code 9. Begin downloading 10.Upon completion of download, call-back Central Station(s) and report a successful download or failed upload/ download status (if programmed to do so) 6.4 Uploading Initiated at a Service Terminal Items that may be uploaded from the control panel to a Service Terminal include: • • • • • All or portions of programmed data plus the real-time clock, time and date Entire Walk Test data file in real-time continuous or as a 'snapshot' Troubleshoot system voltages in real-time continuous or as a 'snapshot' Entire 256 event History File Current system status in real-time continuous or as a 'snapshot' Uploading is possible at any time provided the following conditions are true: ✓ The control panel may be in any mode of operation. Uploading is not possible if the communicator is active or while testing the phone lines while in Troubleshoot Mode ✓ There cannot be any active communications ongoing with the Central Station receiver ✓ All active events must be successfully 'kissed-off' by the Central Stations (communicator must be in a standby state with no new information waiting to be transmitted to a Central Station). Once an incoming call is accepted/answered by the control panel, the panel will: Document #50193 Rev. D 5/2/97 P/N 50193:D 91 Simultaneous Data Transfers 1. Establish basic modem connection 2. Verify secret code 3. Verify callback vs. no callback request from the Service Terminal (if callback is requested, the panel performs steps 4 through 10; if no callback is requested, the panel performs only steps 9 and 10) 4. Identify the Service Terminal location 5. Hang-up/disconnect call 6. Call the Central Station(s) and transmit a request for upload/download message (if programmed to do so). If this message is accepted, the control panel will proceed to the next step 7. Return call to Service Terminal 8. Verify secret code 9. Begin uploading 10.Upon completion of upload, call Central Station(s) back and report a successful upload or failed upload/down- load status (if programmed to do so) During the uploading process, the fire protection remains active. Should a system trouble or alarm condition occur, the control panel immediately terminates uploading and processes the trouble or alarm locally and transmits the information to the Central Station(s). 6.5 Simultaneous Data Transfers Uploading and downloading may take place on a single telephone call. Control and selection of the data transaction is coordinated at the Service Terminal. This eliminates multiple phone calls, allows instant verification of download data files and simplifies the overall process. 92 Document #50193 Rev.D 5/2/97 P/N 50193:D Battery Calculations Battery Calculations Appendix A Use the Total Standby and Alarm Load Currents calculated in Table A-2 and Table A-3 for the following battery calculation. Battery Calculation TABLE A-1: Standby Load Current (amps) [ X ] [ Alarm Load Current (amps) [ ] Required Standby Time in Hours (24 or 60 Hours) X = _______________ = _______________ = _______________ X 1.2 _______________ ] Required Alarm Time in Hours (i.e. 5 min. = 0.084 hours) [ ] Add Standby and Alarm Load for Required Ampere Hour Battery Multiply by derating factor of 1.2 Note: 1. 12 Ampere Hour battery can be located in the backbox. 2. Batteries larger than 12 Ampere Hour, up to 17 Ampere Hour, require the BB-17F battery box. Document #50193 Rev. D 5/2/97 P/N 50193:D 93 Battery Calculations A.1 Main Power Supply The MS-5210UD provides regulated power for operating the fire alarm control panel, operating external devices and operating the standby battery. The power for operating external devices is limited. Use Table A-2 (standby or nonalarm) and Table A-3 (alarm) to determine if external loading is within the capabilities of the power supply. Be certain to power 4-wire smoke detectors from TB2, Terminals 3 and 4. In Table A-2 , external devices are connected to TB2 only. Regulated Load in Standby @24 VDC . TABLE A-2: Device Type # of Devices Current (amps) Total Current (amps) Main Circuit Board 1 X 0.138 = LED-10IM (1 max.) X 0.017 = PRT-24 (1 max.) X 0 = CAC-10F (1 max.) X 0.004 = NAC-REM (1 max.) X 0.002 = 2-wire Detector Heads [ ] X [ ]1 = 4-wire Detector Heads [ ] X [ ]1 = Power Supervision Relays2 [ ] X 0.025 0.138 0 = Current Draw from TB2 (nonalarm3) = Sum Column for Standby Load = amps 1. Refer to the Device Compatibility Document for 2-wire smoke detector standby current. 2. Must use compatible listed Power Supervision Relay. 3. The total standby current must include both the resettable (TB2 Terminals 3 & 4) and nonresettable (TB2 Terminals 1 & 2) power. Caution must be taken to ensure that current drawn from these outputs during alarm does not exceed maximum ratings specified (see Table A-2 ). 94 Document #50193 Rev.D 5/2/97 P/N 50193:D Battery Calculations TABLE A-3: Regulated Load in Alarm @24 VDC . Device Type # of Devices Main Circuit Board 1 LED-10IM PRT-24 CAC-10F NAC-REM 2 Current (amps) Total Current (amps) X 0.245 = (1 max.) X 0.017 = (1 max.) X 0 = (1 max.) X 0.020 = (1 max.) X 0.075 = [ ] X [ ] = Power Supervision Relay3 [ ] X 0.025 = Notification Appliances4 [ ] X [ ] = 5 [ ] x [ ] = 4-wire Smoke Detector Notification Appliances Current Draw from TB2 (alarm current) 0.2451 0 2 = Sum Column for Standby Load6 = amps 1. The current shown represents one zone on the Main Circuit Board in alarm. For all ten zones in alarm, the current draw increases to 0.590 amps with communicator off and 0.610 amps with communicator on. 2. Current limitations of terminals: TB2, Terminals 1 and 2 = 0.500 amps, regulated filtered, 24 VDC +/-5%, 120 Hz ripple @ 10 mVRMS, nonresettable power (100 Hz ripple if MS-5210UDE) TB2, Terminals 3 and 4 = 0.500 amps, regulated filtered, 24 VDC +/-5%, 120 Hz ripple @ 10 mVRMS, resettable power (100 Hz ripple if MS-5210UDE) 3. 4. 5. 6. Must use compatible listed Power Supervision Relay Current limitation of Terminal TB4 circuits is 3.0 amps per Notification Appliance Circuit Current limitations of NAC-REM module circuits is 1.5 amps per Notification Appliance Circuit. Total current draw listed above cannot exceed: • 3.6 amps with standard transformer installed (only) • 6.6 amp with both the standard and optional transformers installed Document #50193 Rev. D 5/2/97 P/N 50193:D 95 Main Panel Options Program Sheets Main Panel Options Program Sheets Appendix B ---To enter Programming Level 1, press the MODE key, 7764, '1', [ENTER/STORE] ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Addresses 00 to 15 store the Primary Central Station Phone Number. Enter 'F' to represent the end of number. ❏ Primary Central Station Communication Format: Enter 0 - F. ❏ ❏ ❏ ❏ Primary Central Station Account Code: Valid keys are 0 - F. ❏ ❏ ❏ ❏ Primary Central Station 24-Hour Test Time. Enter military time (i.e. 1400 for 2:00 PM). ❏ Primary Number Test Time Interval. Enter '0' for 24-hour; '1' for 12-hour; '2' for 8-hour; '3' for 6-hour. ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 16 17 18 19 20 21 22 23 24 27 28 29 25 26 30 31 32 33 34 35 36 37 38 39 40 41 Addresses 26 to 41 store the Secondary Central Station Phone Number. Enter 'F' to represent the end of number. ❏ Secondary Central Station Communication Format: Enter 0 - F. ❏ ❏ ❏ ❏ Secondary Central Station Account Code: Valid keys are 0 - F. ❏ ❏ ❏ ❏ Secondary Central Station 24-Hour Test Time. Enter military time (i.e. 1400 for 2:00 PM). ❏ Secondary Number Test Time Interval. Enter '0' for 24-hour; '1' for 12-hour; '2' for 8-hour; '3' for 6-hour. ❏ Alarm Presignal. Enter '0' to disable; '1' to enable. ❏ ❏ ❏ Alarm Presignal Delay Time. Enter 0 - 179 additional seconds (default = 120 seconds). ❏ Communicator/Fire Panel Selection. Enter '0' for fire panel only; '1' for fire panel/communicator operation. ❏ Backup Reporting. Enter '0' to report to secondary phone number as backup only; '1' to report to both primary 42 43 44 45 46 47 48 49 50 54 55 51 52 53 56 57 and secondary phone number for all reports/messages; '2' reports go to first available receiver. ❏ ❏ ❏ ❏ ❏ ❏ 96 58 Touchtone/Rotary Select for Primary Phone. Enter '0' for touchtone dialing; '1' for rotary dialing. 59 Make/Break Ratio for Primary Phone. Enter '0' for 67/33 ratio; '1' for 62/38 ratio. 60 Touchtone/Rotary Select for Secondary Phone. Enter '0' for touchtone dialing; '1' for rotary dialing. 61 Make/Break Ratio for Secondary Phone. Enter '0' for 67/33 ratio; '1' for 62/38 ratio. 62 Future use. 63 Future use. Document #50193 Rev.D 5/2/97 P/N 50193:D Main Panel Options Program Sheets ❏ Zone 1 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. 64 ❏ 65 Zone 2 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. ❏ Zone 3 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. 66 ❏ 67 Zone 4 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. ❏ Zone 5 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. 68 ❏ 69 Zone 6 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. ❏ Zone 7 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. 70 ❏ 71 Zone 8 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. ❏ Zone 9 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. 72 Document #50193 Rev. D 5/2/97 P/N 50193:D 97 Main Panel Options Program Sheets ❏ 73 Zone 10 Function Select. Enter '0' for 2-wire smoke detectors; '1' for pull station; '2' for normally-open contact devices; '3' for supervisory devices; '4' for supervisory devices (autoresettable); '5' for waterflow (silenceable); '6' for waterflow (nonsilenceable); '7' for process monitoring; '8' for autoresettable process monitoring; '9' for remote reset switch; 'A' for remote silence switch; 'B' for remote acknowledge switch; 'C' for remote manual evacuate (drill) switch. ❏ ❏ Waterflow Retard Timer. Enter 0 - 89 additional seconds. ❏ Alarm Verification. Enter '0' for no verification; '1' for verification of all 2-wire smoke zones. ❏ AC Loss Delay. Enter '0' for 6 hours; '1' for 7 hours; '2' for 8 hours; '3' for 9 hours; '4' for 10 hours; '5' for 11 74 75 76 77 hours; '6' for 12 hours; '7' for 15 hours; '8' for 16 hours; '9' for 17 hours; 'A' for 18 hours; 'B' for 19 hours; 'C' for 20 hours; 'D' for 21 hours; 'E' for 22 hours; 'F' for 23 hours. ❏ Programmable Relay #1 Definition. Enter '0' for alarm; '1' for supervisory; '2' for supervisory autoresettable; '3' for trouble; '4' for communications fail; '5' for process monitoring; '6' for process monitoring autoresettable. 78 ❏ Programmable Relay #2 Definition. Enter '0' for alarm; '1' for supervisory; '2' for supervisory autoresettable; '3' for trouble; '4' for communications fail; '5' for process monitoring; '6' for process monitoring autoresettable. 79 ❏ 80 Notification Appliance Circuit #1 Selection. Enter '0' for enabled (silenceable); '1' for enable (nonsilenceable); '2' for disable. ❏ ❏ 81 Silence Inhibit NAC #1. Enter '0' for no silence inhibit; '1' to inhibit silencing of NAC #1 for one minute. Auto Silence NAC #1. Enter '0' for no auto silence; '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; '6' for 30 minutes. 82 ❏ Coding NAC #1. Enter '0' for steady; '1' for March Time (120 ppm); '2' for California (10 seconds On, 5 seconds Off); '3' for Temporal (½ second On, ½ second Off, ½ second On, ½ second Off, ½ second On, 1½ seconds Off). 83 ❏ Notification Appliance Circuit #2 Selection. Enter '0' for enabled (silenceable); '1' for enable (nonsilenceable); '2' for disable. 84 ❏ ❏ 85 Silence Inhibit NAC #2. Enter '0' for no silence inhibit; '1' to inhibit silencing of NAC #2 for one minute. 86 Auto Silence NAC #2. Enter '0' for no auto silence; '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; '6' for 30 minutes. ❏ Coding NAC #2. Enter '0' for steady; '1' for March Time (120 ppm); '2' for California (10 seconds On, 5 seconds Off); '3' for Temporal (½ second On, ½ second Off, ½ second On, ½ second Off, ½ second On, 1½ seconds Off). 87 ❏ 88 98 Trouble Reminder. Enter '0' to disable; '1' to enable. Document #50193 Rev.D 5/2/97 P/N 50193:D Main Panel Options Program Sheets Main Panel Options Programming Sheets (Factory Default Settings) ---To enter Programming Level 1, press the MODE key, 7764, '1', [ENTER/STORE] F F F F F F F F F F F F F F F F ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Addresses 00 to 15 store the Primary Central Station Phone Number. Enter 'F' to represent the end of number. E ❏ Primary Central Station Communication Format: ('E' for Ademco Contact ID Format). 0 0 0 0 ❏ ❏ ❏ ❏ Primary Central Station Account Code. 0 0 0 0 ❏ ❏ ❏ ❏ Primary Central Station 24-Hour Test Time. 0000 = 12:00 midnight. 0 ❏ Primary Central Station Number Test Time Interval. '0' for 24-hour. F F F ❏ F F F F F F F F F F F F F ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 16 17 18 19 20 21 22 23 24 27 28 29 25 26 30 31 32 33 34 35 36 37 38 39 40 41 Addresses 26 to 41 store the Secondary Central Station Phone Number. Enter 'F' to represent the end of number. E ❏ Secondary Central Station Communication Format: ('E' for Ademco Contact ID Format). 0 0 0 0 ❏ ❏ ❏ ❏ Secondary Central Station Account Code. 0 0 0 0 ❏ ❏ ❏ ❏ Secondary Central Station 24-Hour Test Time. 0000 = 12:00 midnight. 0 ❏ Secondary Number Test Time Interval. '0' for 24-hour. 0 ❏ Alarm Presignal. '0' for no alarm presignal. 1 2 0 ❏ ❏ ❏ Alarm Presignal Delay Time. 120 second alarm presignal delay. 0 ❏ Communicator/Fire Panel Selection. '0' for panel only operation. 0 ❏ Backup Reporting. '0' to report to Secondary Central Station phone # as backup only. 0 ❏ Touchtone/Rotary Select for Primary Phone. '0' for touchtone dialing. 0 ❏ Make/Break Ratio for Primary Phone. '0' for 67/33 ratio. 0 ❏ Touchtone/Rotary Select for Secondary Phone. '0' for touchtone dialing. 0 ❏ Make/Break Ratio for Secondary Phone. '0' for 67/33 ratio. 0 ❏ Future use. Leave default of '0'. 0 ❏ Future use. Leave default of '0'. 0 ❏ Zone 1 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 2 Function Select. '0' for 2-wire smoke detector. 0 ❏ Zone 3 Function Select. '0' for 2-wire smoke detectors. 42 43 44 45 46 47 48 49 50 54 55 51 52 53 56 57 58 59 60 61 62 63 64 65 66 Document #50193 Rev. D 5/2/97 P/N 50193:D 99 Main Panel Options Program Sheets 0 ❏ Zone 4 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 5 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 6 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 7 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 8 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 9 Function Select. '0' for 2-wire smoke detectors. 0 ❏ Zone 10 Function Select. '0' for 2-wire smoke detectors. 0 0 ❏ ❏ Waterflow Retard Timer. '00' for no delay. 0 ❏ Alarm Verification. '0' for no verification. 0 ❏ AC Loss Delay. '0' for 6 hours. 0 ❏ Programmable Relay #1 Definition. '0' for alarm. 3 ❏ Programmable Relay #2 Definition. '3' for trouble. 0 ❏ Notification Appliance Circuit #1 Selection. '0' for enabled (silenceable). 0 ❏ Silence Inhibit NAC #1. '0' for no silence inhibit. 0 ❏ Auto Silence NAC #1. '0' for no auto silence. 0 ❏ Coding NAC #1. '0' for steady, no coding. 0 ❏ Notification Appliance Circuit #2 Selection. '0' for enabled (silenceable). 0 ❏ Silence Inhibit NAC #2. '0' for no silence inhibit. 0 ❏ Auto Silence NAC #2. '0' for no auto silence. 0 ❏ Coding NAC #2. '0' for steady, no coding. 0 ❏ Trouble Reminder. '0' to disable, no trouble reminder. 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 100 Document #50193 Rev.D 5/2/97 P/N 50193:D Event Codes/Transmission Format Programming Sheets Event Codes/Transmission Format Programming Sheets Appendix C ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] 4+2 Standard and 4+2 Express Formats Primary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 0 13 26 39 52 65 78 91 104 117 130 143 156 169 182 195 208 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 1 14 27 40 53 66 79 92 105 118 131 144 157 170 183 196 209 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 2 15 28 41 54 67 80 93 106 119 132 145 158 171 184 197 210 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 3 16 29 42 55 68 81 94 107 120 133 146 159 172 185 198 211 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 4 17 30 43 56 69 82 95 108 121 134 147 160 173 186 199 212 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 5 18 31 44 57 70 83 96 109 122 135 148 161 174 187 200 213 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ Document #50193 6 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 7 19 32 45 58 71 84 97 110 123 136 149 162 175 188 201 214 Rev. D 20 33 46 59 72 85 98 111 124 137 150 163 176 189 202 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 8 21 34 47 60 73 86 99 112 125 138 151 164 177 190 203 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 9 22 35 48 61 74 87 100 113 126 139 152 165 178 191 204 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 10 23 36 49 62 75 88 101 114 127 140 153 166 179 192 205 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 11 24 37 50 63 76 89 102 115 128 141 154 167 180 193 206 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 12 25 38 51 64 77 90 103 116 129 142 155 168 181 194 207 215 5/2/97 P/N 50193:D 101 Event Codes/Transmission Format Programming Sheets Event Codes/Transmission Formats Programming Sheets for 4+2 Standard and 4+2 Express Formats Secondary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 216 229 242 255 268 281 294 307 320 333 346 359 372 385 398 411 424 102 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 217 230 243 256 269 282 295 308 321 334 347 360 373 386 399 412 425 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 218 231 244 257 270 283 296 309 322 335 348 361 374 387 400 413 426 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 219 232 245 258 271 284 297 310 323 336 349 362 375 388 401 414 427 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 220 233 246 259 272 285 298 311 324 337 350 363 376 389 402 415 428 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 221 234 247 260 273 286 299 312 325 338 351 364 377 390 403 416 429 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 222 235 248 261 274 287 300 313 326 339 352 365 378 391 404 417 430 Document #50193 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 223 236 249 262 275 288 301 314 327 340 353 366 379 392 405 418 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 224 237 250 263 276 289 302 315 328 341 354 367 380 393 406 419 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 431 Rev.D 5/2/97 P/N 50193:D 225 238 251 264 277 290 303 316 329 342 355 368 381 394 407 420 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 226 239 252 265 278 291 304 317 330 343 356 369 382 395 408 421 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 227 240 253 266 279 292 305 318 331 344 357 370 383 396 409 422 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 228 241 254 267 280 293 306 319 332 345 358 371 384 397 410 423 Event Codes/Transmission Format Programming Sheets ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] Event Codes/Transmission Format Programming Reference Sheet (factory defaults) 4+2 Standard and 4+2 Express Formats Primary Central Station 1 ❏ 7 ❏ 4 ❏ A ❏ F ❏ 1 ❏ 6 ❏ A ❏ E ❏ 8 ❏ 5 ❏ 8 ❏ D ❏ 2 ❏ A ❏ B ❏ 7 ❏ 0 13 26 39 52 65 78 91 104 117 130 143 156 169 182 195 208 1 ❏ 1 ❏ 4 ❏ 9 ❏ 5 ❏ 6 ❏ 8 ❏ 6 ❏ 2 ❏ E ❏ 5 ❏ 9 ❏ 6 ❏ A ❏ 9 ❏ A ❏ 1 ❏ 1 14 27 40 53 66 79 92 105 118 131 144 157 170 183 196 209 1 ❏ 8 ❏ 4 ❏ 7 ❏ F ❏ 2 ❏ 6 ❏ B ❏ E ❏ 9 ❏ 5 ❏ 3 ❏ D ❏ 3 ❏ 5 ❏ C ❏ 7 ❏ 2 15 28 41 54 67 80 93 106 119 132 145 158 171 184 197 210 2 ❏ 1 ❏ 5 ❏ 9 ❏ 6 ❏ 6 ❏ 9 ❏ 6 ❏ 3 ❏ E ❏ 6 ❏ D ❏ 7 ❏ A ❏ B ❏ A ❏ 2 ❏ 3 16 29 42 55 68 81 94 107 120 133 146 159 172 185 198 211 1 ❏ 9 ❏ 4 ❏ 2 ❏ F ❏ 3 ❏ 4 ❏ C ❏ E ❏ A ❏ 5 ❏ 1 ❏ D ❏ 4 ❏ 5 ❏ D ❏ 7 ❏ 4 17 30 43 56 69 82 95 108 121 134 147 160 173 186 199 212 3 ❏ 1 ❏ 6 ❏ F ❏ 7 ❏ 6 ❏ B ❏ 6 ❏ 4 ❏ 5 ❏ 7 ❏ D ❏ 8 ❏ A ❏ C ❏ A ❏ 3 ❏ 5 18 31 44 57 70 83 96 109 122 135 148 161 174 187 200 213 1 ❏ A ❏ 4 ❏ 1 ❏ F ❏ 4 ❏ 4 ❏ D ❏ E ❏ 1 ❏ 5 ❏ 2 ❏ D ❏ 5 ❏ 5 ❏ E ❏ 7 ❏ Document #50193 6 4 ❏ 4 ❏ 7 ❏ F ❏ 8 ❏ 6 ❏ C ❏ 6 ❏ 5 ❏ 5 ❏ 8 ❏ D ❏ 9 ❏ A ❏ D ❏ A ❏ 4 ❏ 7 19 32 45 58 71 84 97 110 123 136 149 162 175 188 201 214 Rev. D 20 33 46 59 72 85 98 111 124 137 150 163 176 189 202 1 ❏ 1 ❏ 4 ❏ 2 ❏ F ❏ 5 ❏ 4 ❏ E ❏ E ❏ 2 ❏ 5 ❏ 3 ❏ D ❏ 6 ❏ 5 ❏ F ❏ 8 21 34 47 60 73 86 99 112 125 138 151 164 177 190 203 5 ❏ 4 ❏ 8 ❏ F ❏ 9 ❏ 6 ❏ D ❏ 6 ❏ 6 ❏ 5 ❏ 9 ❏ D ❏ A ❏ A ❏ E ❏ 9 ❏ 9 22 35 48 61 74 87 100 113 126 139 152 165 178 191 204 1 ❏ 2 ❏ 4 ❏ 3 ❏ F ❏ 6 ❏ 4 ❏ F ❏ E ❏ 3 ❏ 5 ❏ 4 ❏ A ❏ 7 ❏ A ❏ 9 ❏ 10 23 36 49 62 75 88 101 114 127 140 153 166 179 192 205 6 ❏ 4 ❏ 9 ❏ F ❏ A ❏ 6 ❏ E ❏ E ❏ 7 ❏ 5 ❏ A ❏ D ❏ 1 ❏ A ❏ A ❏ 9 ❏ 11 24 37 50 63 76 89 102 115 128 141 154 167 180 193 206 1 ❏ 3 ❏ 4 ❏ 4 ❏ 6 ❏ 7 ❏ 6 ❏ 1 ❏ E ❏ 4 ❏ 9 ❏ 5 ❏ A ❏ 8 ❏ A ❏ 1 ❏ 12 25 38 51 64 77 90 103 116 129 142 155 168 181 194 207 215 5/2/97 P/N 50193:D 103 Event Codes/Transmission Format Programming Sheets Event Codes/Transmission Formats Programming Reference Sheet (factory defaults) for 4+2 Standard and 4+2 Express Formats Secondary Central Station 1 ❏ 7 ❏ 4 ❏ A ❏ F ❏ 1 ❏ 6 ❏ A ❏ E ❏ 8 ❏ 5 ❏ 8 ❏ D ❏ 2 ❏ A ❏ B ❏ 7 ❏ 216 229 242 255 268 281 294 307 320 333 346 359 372 385 398 411 424 104 1 ❏ 1 ❏ 4 ❏ 9 ❏ 5 ❏ 6 ❏ 8 ❏ 6 ❏ 2 ❏ E ❏ 5 ❏ 9 ❏ 6 ❏ A ❏ 9 ❏ A ❏ 1 ❏ 217 230 243 256 269 282 295 308 321 334 347 360 373 386 399 412 425 1 ❏ 8 ❏ 4 ❏ 7 ❏ F ❏ 2 ❏ 6 ❏ B ❏ E ❏ 9 ❏ 5 ❏ 3 ❏ D ❏ 3 ❏ 5 ❏ C ❏ 7 ❏ 218 231 244 257 270 283 296 309 322 335 348 361 374 387 400 413 426 2 ❏ 1 ❏ 5 ❏ 9 ❏ 6 ❏ 6 ❏ 9 ❏ 6 ❏ 3 ❏ E ❏ 6 ❏ D ❏ 7 ❏ A ❏ B ❏ A ❏ 2 ❏ 219 232 245 258 271 284 297 310 323 336 349 362 375 388 401 414 427 1 ❏ 9 ❏ 4 ❏ 2 ❏ F ❏ 3 ❏ 4 ❏ C ❏ E ❏ A ❏ 5 ❏ 1 ❏ D ❏ 4 ❏ 5 ❏ D ❏ 7 ❏ 220 233 246 259 272 285 298 311 324 337 350 363 376 389 402 415 428 3 ❏ 1 ❏ 6 ❏ F ❏ 7 ❏ 6 ❏ B ❏ 6 ❏ 4 ❏ 5 ❏ 7 ❏ D ❏ 8 ❏ A ❏ C ❏ A ❏ 3 ❏ 221 234 247 260 273 286 299 312 325 338 351 364 377 390 403 416 429 1 ❏ A ❏ 4 ❏ 1 ❏ F ❏ 4 ❏ 4 ❏ D ❏ E ❏ 1 ❏ 5 ❏ 2 ❏ D ❏ 5 ❏ 5 ❏ E ❏ 7 ❏ 222 235 248 261 274 287 300 313 326 339 352 365 378 391 404 417 430 Document #50193 4 ❏ 4 ❏ 7 ❏ F ❏ 8 ❏ 6 ❏ C ❏ 6 ❏ 5 ❏ 5 ❏ 8 ❏ D ❏ 9 ❏ A ❏ D ❏ A ❏ 4 ❏ 223 236 249 262 275 288 301 314 327 340 353 366 379 392 405 418 1 ❏ 1 ❏ 4 ❏ 2 ❏ F ❏ 5 ❏ 4 ❏ E ❏ E ❏ 2 ❏ 5 ❏ 3 ❏ D ❏ 6 ❏ 5 ❏ F ❏ 224 237 250 263 276 289 302 315 328 341 354 367 380 393 406 419 5 ❏ 4 ❏ 8 ❏ F ❏ 9 ❏ 6 ❏ D ❏ 6 ❏ 6 ❏ 5 ❏ 9 ❏ D ❏ A ❏ A ❏ E ❏ 9 ❏ 431 Rev.D 5/2/97 P/N 50193:D 225 238 251 264 277 290 303 316 329 342 355 368 381 394 407 420 1 ❏ 2 ❏ 4 ❏ 3 ❏ F ❏ 6 ❏ 4 ❏ F ❏ E ❏ 3 ❏ 5 ❏ 4 ❏ A ❏ 7 ❏ A ❏ 9 ❏ 226 239 252 265 278 291 304 317 330 343 356 369 382 395 408 421 6 ❏ 4 ❏ 9 ❏ F ❏ A ❏ 6 ❏ E ❏ E ❏ 7 ❏ 5 ❏ A ❏ D ❏ 1 ❏ A ❏ A ❏ 9 ❏ 227 240 253 266 279 292 305 318 331 344 357 370 383 396 409 422 1 ❏ 3 ❏ 4 ❏ 4 ❏ 6 ❏ 7 ❏ 6 ❏ 1 ❏ E ❏ 4 ❏ 9 ❏ 5 ❏ A ❏ 8 ❏ A ❏ 1 ❏ 228 241 254 267 280 293 306 319 332 345 358 371 384 397 410 423 Event Codes/Transmission Format Programming Sheets ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] Event Codes/Transmission Format Programming Sheets for All 3+1, All 4+1 and 4+2 Expanded Formats Primary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 0 13 26 39 52 65 78 91 104 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 1 14 27 40 53 66 79 92 105 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 2 15 28 41 54 67 80 93 106 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 3 16 29 42 55 68 81 94 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 4 17 30 43 56 69 82 95 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 5 18 31 44 57 70 83 96 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 6 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 7 19 32 45 58 71 84 97 20 33 46 59 72 85 98 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 8 21 34 47 60 73 86 99 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 9 22 35 48 61 74 87 100 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 10 23 36 49 62 75 88 101 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 11 24 37 50 63 76 89 102 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 12 25 38 51 64 77 90 103 107 Event Codes/Transmission Format Programming Sheets for All 3+1, All 4+1 and 4+2 Expanded Formats Secondary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 216 229 242 255 268 281 294 307 320 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 217 230 243 256 269 282 295 308 321 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 218 231 244 257 270 283 296 309 322 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 219 232 245 258 271 284 297 310 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 220 233 246 259 272 285 298 311 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 221 234 247 260 273 286 299 312 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 222 235 248 261 274 287 300 313 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 223 236 249 262 275 288 301 314 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 224 237 250 263 276 289 302 315 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 225 238 251 264 277 290 303 316 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 226 239 252 265 278 291 304 317 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 227 240 253 266 279 292 305 318 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 228 241 254 267 280 293 306 319 323 Document #50193 Rev. D 5/2/97 P/N 50193:D 105 Event Codes/Transmission Format Programming Sheets ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] Event Codes/Format Programming Reference Sheets Factory Defaults for All 3+1, All 4+1 and 4+2 Expanded Formats Primary Central Station 1 ❏ 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ A ❏ 7 ❏ 0 13 26 39 52 65 78 91 104 1 ❏ 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 1 14 27 40 53 66 79 92 105 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 2 15 28 41 54 67 80 93 106 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 3 16 29 42 55 68 81 94 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 4 17 30 43 56 69 82 95 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ A ❏ A ❏ 5 18 31 44 57 70 83 96 1 ❏ 4 ❏ 6 ❏ 6 ❏ E ❏ 9 ❏ A ❏ A ❏ 6 19 32 45 58 71 84 97 1 ❏ 9 ❏ 6 ❏ 6 ❏ E ❏ 9 ❏ A ❏ A ❏ 1 ❏ 9 ❏ 6 ❏ 6 ❏ E ❏ D ❏ A ❏ A ❏ 7 8 20 21 33 34 46 47 59 60 72 73 85 86 98 99 1 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ A ❏ 9 22 35 48 61 74 87 100 4 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ A ❏ 10 23 36 49 62 75 88 101 4 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ 9 ❏ 11 24 37 50 63 76 89 102 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ A ❏ F ❏ 12 25 38 51 64 77 90 103 107 Event Codes/Format Programming Reference Sheet Factory Defaults for All 3+1, All 4+1 and 4+2 Expanded Formats Secondary Central Station 1 ❏ 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ A ❏ 7 ❏ 216 229 242 255 268 281 294 307 320 106 1 ❏ 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 217 230 243 256 269 282 295 308 321 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 218 231 244 257 270 283 296 309 322 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 7 ❏ 219 232 245 258 271 284 297 310 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ D ❏ 5 ❏ 220 233 246 259 272 285 298 311 1 ❏ 4 ❏ F ❏ 4 ❏ E ❏ 5 ❏ A ❏ A ❏ 221 234 247 260 273 286 299 312 1 ❏ 4 ❏ 6 ❏ 6 ❏ E ❏ 9 ❏ A ❏ A ❏ 222 235 248 261 274 287 300 313 1 ❏ 9 ❏ 6 ❏ 6 ❏ E ❏ 9 ❏ A ❏ A ❏ 223 236 249 262 275 288 301 314 1 ❏ 9 ❏ 6 ❏ 6 ❏ E ❏ D ❏ A ❏ A ❏ 224 237 250 263 276 289 302 315 1 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ A ❏ 323 Document #50193 Rev.D 5/2/97 P/N 50193:D 225 238 251 264 277 290 303 316 4 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ A ❏ 226 239 252 265 278 291 304 317 4 ❏ F ❏ 6 ❏ 6 ❏ 5 ❏ D ❏ A ❏ 9 ❏ 227 240 253 266 279 292 305 318 4 ❏ F ❏ 6 ❏ E ❏ 5 ❏ D ❏ A ❏ F ❏ 228 241 254 267 280 293 306 319 Event Codes/Transmission Format Programming Sheets ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] Event Codes/Transmission Format Programming Sheets for Ademco Contact ID Primary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 0 13 26 39 52 65 78 91 104 117 130 143 156 169 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 1 14 27 40 53 66 79 92 105 118 131 144 157 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 2 15 28 41 54 67 80 93 106 119 132 145 158 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 3 16 29 42 55 68 81 94 107 120 133 146 159 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 4 17 30 43 56 69 82 95 108 121 134 147 160 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 5 18 31 44 57 70 83 96 109 122 135 148 161 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 6 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 7 19 32 45 58 71 84 97 110 123 136 149 162 20 33 46 59 72 85 98 111 124 137 150 163 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 8 21 34 47 60 73 86 99 112 125 138 151 164 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 9 22 35 48 61 74 87 100 113 126 139 152 165 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 10 23 36 49 62 75 88 101 114 127 140 153 166 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 11 24 37 50 63 76 89 102 115 128 141 154 167 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 12 25 38 51 64 77 90 103 116 129 142 155 168 170 Document #50193 Rev. D 5/2/97 P/N 50193:D 107 Event Codes/Transmission Format Programming Sheets Event Codes/Transmission Format Programming Sheets for Ademco Contact ID Secondary Central Station ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 216 229 242 255 268 281 294 307 320 333 346 359 372 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 217 230 243 256 269 282 295 308 321 334 347 360 373 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 218 231 244 257 270 283 296 309 322 335 348 361 374 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 219 232 245 258 271 284 297 310 323 336 349 362 375 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 220 233 246 259 272 285 298 311 324 337 350 363 376 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 221 234 247 260 273 286 299 312 325 338 351 364 377 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 222 235 248 261 274 287 300 313 326 339 352 365 378 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 223 236 249 262 275 288 301 314 327 340 353 366 379 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 224 237 250 263 276 289 302 315 328 341 354 367 380 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 385 108 386 Document #50193 Rev.D 5/2/97 P/N 50193:D 225 238 251 264 277 290 303 316 329 342 355 368 381 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 226 239 252 265 278 291 304 317 330 343 356 369 382 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 227 240 253 266 279 292 305 318 331 344 357 370 383 ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 228 241 254 267 280 293 306 319 332 345 358 371 384 Event Codes/Transmission Format Programming Sheets ---To enter Programming Level 2, press the MODE key, 7764, '2', [ENTER/STORE] Event Codes/Transmission Format Programming Sheet Factory Default for Ademco Contact ID Primary Central Station 1 ❏ 1 ❏ 1 ❏ 5 ❏ 7 ❏ 1 ❏ 3 ❏ 8 ❏ 1 ❏ 3 ❏ 2 ❏ 6 ❏ 6 ❏ 1 ❏ 0 13 26 39 52 65 78 91 104 117 130 143 156 169 1 ❏ 1 ❏ 1 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 6 ❏ 3 ❏ 0 ❏ 3 ❏ 1 14 27 40 53 66 79 92 105 118 131 144 157 1 ❏ 1 ❏ 1 ❏ 0 ❏ 5 ❏ 8 ❏ 0 ❏ 3 ❏ 5 ❏ 6 ❏ 5 ❏ 3 ❏ 8 ❏ 2 15 28 41 54 67 80 93 106 119 132 145 158 1 ❏ 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 1 ❏ 3 ❏ 2 ❏ 0 ❏ 4 ❏ 3 16 29 42 55 68 81 94 107 120 133 146 159 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 7 ❏ 3 ❏ 1 ❏ 4 17 30 43 56 69 82 95 108 121 134 147 160 1 ❏ 1 ❏ 7 ❏ 0 ❏ 5 ❏ 8 ❏ 0 ❏ 3 ❏ 5 ❏ 7 ❏ 3 ❏ 3 ❏ 1 ❏ 5 18 31 44 57 70 83 96 109 122 135 148 161 1 ❏ 1 ❏ 0 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 1 ❏ 2 ❏ 5 ❏ 5 ❏ 0 ❏ 4 ❏ 6 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 4 ❏ 3 ❏ 1 ❏ 7 19 32 45 58 71 84 97 110 123 136 149 162 20 33 46 59 72 85 98 111 124 137 150 163 1 ❏ 1 ❏ 7 ❏ 0 ❏ 6 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 1 ❏ 3 ❏ 0 ❏ 6 ❏ 8 21 34 47 60 73 86 99 112 125 138 151 164 1 ❏ 1 ❏ 0 ❏ 5 ❏ 0 ❏ 0 ❏ 3 ❏ 0 ❏ 1 ❏ 5 ❏ 5 ❏ 8 ❏ 4 ❏ 9 22 35 48 61 74 87 100 113 126 139 152 165 1 ❏ 1 ❏ 5 ❏ 7 ❏ 4 ❏ 3 ❏ 8 ❏ 2 ❏ 3 ❏ 2 ❏ 4 ❏ 6 ❏ 1 ❏ 10 23 36 49 62 75 88 101 114 127 140 153 166 1 ❏ 1 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 2 ❏ 3 ❏ 0 ❏ 2 ❏ 11 24 37 50 63 76 89 102 115 128 141 154 167 1 ❏ 1 ❏ 0 ❏ 5 ❏ 0 ❏ 0 ❏ 3 ❏ 1 ❏ 2 ❏ 5 ❏ 3 ❏ 2 ❏ 4 ❏ 12 25 38 51 64 77 90 103 116 129 142 155 168 170 Document #50193 Rev. D 5/2/97 P/N 50193:D 109 Event Codes/Transmission Format Programming Sheets Event Codes/Transmission Format Programming Sheet Factory Defaults for Ademco Contact ID Secondary Central Station 1 ❏ 1 ❏ 1 ❏ 5 ❏ 7 ❏ 1 ❏ 3 ❏ 8 ❏ 1 ❏ 3 ❏ 2 ❏ 6 ❏ 6 ❏ 1 ❏ 216 229 242 255 268 281 294 307 320 333 346 359 372 385 110 1 ❏ 1 ❏ 1 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 6 ❏ 3 ❏ 0 ❏ 3 ❏ 217 230 243 256 269 282 295 308 321 334 347 360 373 1 ❏ 1 ❏ 1 ❏ 0 ❏ 5 ❏ 8 ❏ 0 ❏ 3 ❏ 5 ❏ 6 ❏ 5 ❏ 3 ❏ 8 ❏ 218 231 244 257 270 283 296 309 322 335 348 361 374 1 ❏ 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 1 ❏ 3 ❏ 2 ❏ 0 ❏ 4 ❏ 219 232 245 258 271 284 297 310 323 336 349 362 375 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 7 ❏ 3 ❏ 1 ❏ 220 233 246 259 272 285 298 311 324 337 350 363 376 1 ❏ 1 ❏ 7 ❏ 0 ❏ 5 ❏ 8 ❏ 0 ❏ 3 ❏ 5 ❏ 7 ❏ 3 ❏ 3 ❏ 1 ❏ 221 234 247 260 273 286 299 312 325 338 351 364 377 1 ❏ 1 ❏ 0 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 1 ❏ 2 ❏ 5 ❏ 5 ❏ 0 ❏ 4 ❏ 222 235 248 261 274 287 300 313 326 339 352 365 378 1 ❏ 1 ❏ 5 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 4 ❏ 3 ❏ 1 ❏ 223 236 249 262 275 288 301 314 327 340 353 366 379 1 ❏ 1 ❏ 7 ❏ 0 ❏ 6 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 1 ❏ 3 ❏ 0 ❏ 6 ❏ 224 237 250 263 276 289 302 315 328 341 354 367 380 1 ❏ 1 ❏ 0 ❏ 5 ❏ 0 ❏ 0 ❏ 3 ❏ 0 ❏ 1 ❏ 5 ❏ 5 ❏ 8 ❏ 4 ❏ 386 Document #50193 Rev.D 5/2/97 P/N 50193:D 225 238 251 264 277 290 303 316 329 342 355 368 381 1 ❏ 1 ❏ 5 ❏ 7 ❏ 4 ❏ 3 ❏ 8 ❏ 2 ❏ 3 ❏ 2 ❏ 4 ❏ 6 ❏ 1 ❏ 226 239 252 265 278 291 304 317 330 343 356 369 382 1 ❏ 1 ❏ 7 ❏ 0 ❏ 3 ❏ 8 ❏ 0 ❏ 3 ❏ 2 ❏ 2 ❏ 3 ❏ 0 ❏ 2 ❏ 227 240 253 266 279 292 305 318 331 344 357 370 383 1 ❏ 1 ❏ 0 ❏ 5 ❏ 0 ❏ 0 ❏ 3 ❏ 1 ❏ 2 ❏ 5 ❏ 3 ❏ 2 ❏ 4 ❏ 228 241 254 267 280 293 306 319 332 345 358 371 384 Ademco Contact ID Format Event Code Descriptions Ademco Contact ID Format Event Code Descriptions Appendix D This appendix describes the various Event Codes and their messages which are available for the Ademco Contact ID Format. The reporting structure for the Ademco Contact ID Format is as follows: SSS 18 QXYZ GG CCC where SSSS = Four digit Subscriber ID Account Code (addresses 17 - 20 and 43 - 46) 18 = Identifies transmission as Contact ID to the receiver at the Central Station Q = Event Qualifier where 1 = New Event and 3 = New Restore XYZ = Event code (shown in Table 3-5 and Table 3-8 ) GG = Group number CCC = Zone number Notes: 1. GG Group Number is fixed at '00' and cannot be changed. 2. CCC Zone Number is transmitted as '001' for zone one up to '010' for zone 10. Ademco Contact ID Reporting Structure A typical printout from a Central Station receiver (such as the Ademco 685) of alarm and trouble reports in the Ademco Contact ID Reporting Structure follows: Time Date Rcvr/Line ID SSSS QXYZ GG CCCC 11:28 03/25 11 7777 E110 00 C001 - general fire alarm on zone one 11:28 03/25 11 7777 E111 00 C002 - smoke detector alarm on zone two 11:28 03/25 11 7777 E380 00 C003 - fault on zone three 11:28 03/25 11 7777 E570 00 C009 - Zone nine disabled 11:28 03/25 11 7777 R110 00 C001 - Zone one alarm restored 11:28 03/25 11 7777 R111 00 C002 - smoke detector zone two restored 11:28 03/25 11 7777 R380 00 C003 - zone three fault restored 11:28 03/25 11 7777 R570 00 C009 - zone nine reenabled 11:28 03/25 11 7777 E158 00 C006 - high temperature, zone six 11:28 03/25 11 7777 E151 00 C007 - gas detected, zone seven Notes: 1. 18, which is used in the reporting structure to identify the transmission as Contact ID, is not printed out in the alarm and trouble report. 2. Q, which is the Event Qualifier for the reporting structure, is printed out in the report as an E for New Event or R for New Restore. Document #50193 Rev. D 5/2/97 P/N 50193:D 111 Ademco Contact ID Format Event Code Descriptions EVENT CODE CLASSIFICATIONS 100 ALARMS Medical Fire Panic Burglary General 24 Hour 200 SUPERVISORY Fire 300 TROUBLES 400 OPEN/CLOSE REMOTE ACCESS System Sounder/Relay System Peripheral Communication Protective Loop Sensor Open/Close Remote Access Access Control System Sounder/Relay System Peripheral Communication EVENT Medical Alarms - 100 100 Medical 101 Pendant transmitter 102 Fail to report in EMERG - Personal Emergency - # EMERG - Personal Emergency - # EMERG - Fail to Check-in - # Fire Alarms - 110 110 Fire Alarm 111 Smoke 112 Combustion 113 Waterflow 114 Heat 115 Pull station 116 Duct 117 Flame 118 Near Alarm FIRE - Fire Alarm - # FIRE - Smoke Detector - # FIRE - Combustion - # FIRE - Waterflow - # FIRE - Heat Sensor - # FIRE - Pull Station - # FIRE - Duct Sensor - # FIRE - Flame Sensor - # FIRE - Near Alarm - # Panic Alarms - 120 120 Panic Alarm 121 Duress 122 Silent 123 Audible PANIC - Panic - # PANIC - Duress PANIC - Silent Panic - # PANIC - Audible Panic - # Burglar Alarms - 130 130 Burglary 131 Perimeter 132 Interior 133 24-Hour 134 Entry/Exit 135 Day/Night 136 Outdoor 137 Tamper 138 Near Alarm BURG - Burglary - # BURG - Perimeter - # BURG - Interior - # BURG - 24-Hour - # BURG - Entry/Exit - # BURG - Day/Night - # BURG - Outdoor - # BURG - Tamper - # BURG - Near Alarm - # General Alarms - 140 140 General Alarm 141 Polling loop open 142 Polling loop short 143 Expansion module failure 144 Sensor tamper 145 Expansion module tamper 112 500 DISABLES/ BYPASSES MESSAGE ALARM - General Alarm - # ALARM - Polling Loop Open - # ALARM - Polling Loop Short - # ALARM - Exp. Module Fail - # ALARM - Sensor Tamper - # ALARM - Exp. Module Tamper - # Document #50193 Rev.D 5/2/97 P/N 50193:D 600 TEST/ MISC. Test Ademco Contact ID Format Event Code Descriptions EVENT 24 Hour Non-Burglary - 150 and 160 150 24-Hour Non-Burg 151 Gas detected 152 Refrigeration 153 Loss of heat 154 Water leakage 155 Foil break 156 Day trouble 157 Low bottled gas level 158 High temp 159 Low temp 161 Loss of air flow MESSAGE ALARM - 24-Hr. Non-Burg - # ALARM - Gas Detected - # ALARM - Refrigeration - # ALARM - Heating System - # ALARM - Eater Leakage - # ALARM - Foil Break - # ALARM - Day Zone - # ALARM - Low Gas Level - # ALARM - High Temperature - # ALARM - Low Temperature - # ALARM - Air Flow - # Fire Supervisory - 200 and 210 200 Fire supervisory 201 Low water pressure 202 Lox CO2 203 Gate valve sensor 204 Low water level 205 Pump activated 206 Pump failure SUPER. - Fire Supervisory - # SUPER. - Low Water Pressure - # SUPER. - Low CO2 SUPER. - Gate Valve - # SUPER. - Low Water Level - # SUPER. - Pump Activation - # SUPER. - Pump Failure - # System Troubles - 300 and 310 300 System trouble 301 AC loss 302 Low system battery 303 RAM checksum bad 304 ROM checksum bad 305 System reset 306 Panel program changed 307 Self-test failure 308 System shutdown 309 Battery test failure 310 Ground fault 311 No battery TROUBLE - System Trouble TROUBLE - AC Power TROUBLE - System Low Battery TROUBLE - Bad RAM Checksum (Restore not applicable) TROUBLE - Bad ROM Checksum (Restore not applicable) TROUBLE - System Reset (Restore not applicable) TROUBLE - Programming Changed (Restore not applicable) TROUBLE - Self Test Failure TROUBLE - System Shutdown TROUBLE - Battery Test Failure TROUBLE - Ground Fault - # TROUBLE - No Battery Sounder/Relay Troubles - 320 320 Sounder/Relay 321 Bell 1 322 Bell 2 323 Alarm relay 324 Trouble relay 325 Reversing 326 Bell 3 327 Bell 4 TROUBLE - Sounder Relay - # TROUBLE - Bell/Siren #1 TROUBLE - Bell/Siren #2 TROUBLE - Alarm Relay TROUBLE - Trouble Relay TROUBLE - Reversing Relay TROUBLE - Bell/Siren #3 TROUBLE - Bell/Siren #4 System Peripheral Troubles - 330 and 340 330 System peripheral TROUBLE - Sys. Peripheral - # 331 Polling loop open TROUBLE - Polling Loop Open 332 Polling loop short TROUBLE - Polling Loop Short 333 Expansion module failure TROUBLE - Exp. Module Fail - # 334 Repeater failure TROUBLE - Repeater Failure - # 335 Local printer paper out TROUBLE - Printer Paper Out 336 Local printer failure TROUBLE - Local Printer Document #50193 Rev. D 5/2/97 P/N 50193:D 113 Ademco Contact ID Format Event Code Descriptions EVENT MESSAGE Communication Troubles - 350 and 360 350 Communication TROUBLE - Communication Trouble 351 Telco 1 fault TROUBLE - Phone Line #1 352 Telco 2 fault TROUBLE - Phone Line #2 353 Long range radio xmitter fault TROUBLE - Radio Transmitter 354 Fail to communicate TROUBLE - Fail to Communicate 355 Loss of radio supervision TROUBLE - Radio Supervision 356 Loss of central polling TROUBLE - Central Radio Polling Protection Loop Troubles - 370 370 Protection loop 371 Protection loop open 372 Protection loop short 373 Fire Trouble TROUBLE - Protection Loop - # TROUBLE - Protection Loop Open - # TROUBLE - Protection Loop Short - # TROUBLE - Fire Loop - # Sensor Troubles - 380 380 Sensor trouble 381 Loss of supervision - RF 382 Loss of supervision - RPM 383 Sensor tamper 384 RF transmitter low battery TROUBLE - Sensor Trouble - # TROUBLE - RF Sensor Supervision - # TROUBLE - RPM Sensor Supervision - # TROUBLE - Sensor Tamper - # TROUBLE - RF Sensor Batt. - # Open/Close - 400 400 Open/Close 401 Open/Close by user 402 Group Open/Close 403 Automatic Open/Close 404 Late Open/Close 405 Deferred Open/Close 406 Cancel 407 Remote arm/disarm 408 Quick arm 409 Keyswitch Open/Close OPENING CLOSING OPENING - User # CLOSING - User # OPENING - Group User # CLOSING - Group User # OPENING - Automatic CLOSING - Automatic OPENING - Late CLOSING - Late Opening not used Closing not used OPENING - Cancel Closing not used OPENING - Remote CLOSING - Remote Opening not applicable CLOSING - Quick arm OPENING - Keyswitch CLOSING - Keyswitch Remote Access - 410 411 Callback request made 412 Success - download/access 413 Unsuccessful access 414 System shutdown 415 Dialer shutdown 416 Success - upload/access REMOTE - Callback Requested REMOTE - Successful Access REMOTE - Unsuccessful Access REMOTE - System Shutdown REMOTE - Dialer Shutdown REMOTE - Successful Access Access Control - 420 421 Access denied 422 Access report by user ACCESS - Access Denied - User # Restore not used ACCESS - Access Gained - User # Restore not used System Disables - 500 and 510 114 Document #50193 Rev.D 5/2/97 P/N 50193:D Restore not applicable Restore not applicable Restore not applicable Restore not applicable Ademco Contact ID Format Event Code Descriptions EVENT Sounder/Relay Disables - 520 520 Sounder/Relay disable 521 Bell 1 disable 522 Bell 2 disable 523 Alarm relay disable 524 Trouble relay disable 525 Reversing relay disable 526 Bell 3 disable 527 Bell 4 disable MESSAGE DISABLE - Sounder/Relay - # DISABLE - Bell/Siren - #1 DISABLE - Bell/Siren - #2 DISABLE - Alarm Relay DISABLE - Trouble Relay DISABLE - Reversing Relay DISABLE - Bell/Siren - #3 DISABLE - Bell/Siren - #4 System Peripheral Disables - 530 and 540 Communication Disables - 550 and 560 551 Dialer disabled DISABLE - Dialer Disable 552 Radio transmitter disabled DISABLE - Radio Disable Bypasses - 570 570 Zone bypass 571 Fire bypass 572 24-Hour zone bypass 573 Burglar bypass 574 Group bypass BYPASS - Zone Bypass - # BYPASS - Fire Bypass - # BYPASS - 24-Hour Bypass - # BYPASS - Burg. Bypass - # BYPASS - Group Bypass - # Test Misc. - 600 601 Manual trigger test 602 Periodic test report 603 Periodic RF transmission 604 Fire test 605 Status report to follow 606 Listen-in to follow 607 Walk test mode 608 System abnormal test TEST - Manually Triggered TEST - Periodic TEST - Periodic Radio TEST - Fire Test STATUS - Status Follows LISTEN - Listen-in Active TEST - Walk Test Mode TEST - System Abnormal Test Document #50193 Rev. D 5/2/97 P/N 50193:D Restore not applicable Restore not applicable Restore not applicable Restore not used Restore not applicable Restore not applicable 115 Option Modules Programming Sheets Appendix E Option Modules Programming Sheets ---To enter Programming Level 3, press the MODE key, 7764, '3', [ENTER/STORE] ❏ ❏ 0 CAC-10F Class A Converter Card installed. Factory default is '0' for card not installed; enter '1' to install card. 1 LED-10IM EIA-485 Interface Module installed. Factory default is '0' for no module installed; enter '1' to install card. ❏ ❏ Annunciator or ACM-8RF maximum monitored address on EIA-485 line. Factory default is address 2 = 0, address 3 = 1. Enter the two digit address set on the switches of the annunciator or ACM-8RF Remote Relay module with the highest (maximum) address. 2 3 ❏ 4 Printer installed. Factory default is '0' for printer not installed; enter '1' to install printer (requires PRT-24 Printer Interface Module. ❏ ❏ ❏ 5 Printer Baud Rate. Factory default is '0' for 2400 Baud; enter '1' for 4800 Baud; '2' for 9600 Baud. 6 NAC/Relay Option Module installed. Factory default is '0' for no module installed; enter '1' to install module. Programmable Relay #3 Definition. This selection determines the panel condition which will cause Relay #3 to activate. Factory default is '1' for supervisory; enter '0' for alarm; '2' for supervisory autoresettable, '3' for trouble; '4' for communication fail; '5' for process monitoring; '6' for autoresettable process monitoring. 7 ❏ 8 Programmable Relay #4 Definition. This selection determines the panel condition which will cause Relay #4 to activate. Factory default is '4' for communication fail; enter '0' for alarm; '1' for supervisory; '2' for supervisory autoresettable; '3' for trouble; '5' for process monitoring; '6' for autoresettable process monitoring. ❏ NAC #3 Type Selection. Factory default is '0' for NAC #3 enabled (silenceable); enter '1' for enabled (nonsilenceable); '2' for disabled. 9 ❏ 10 NAC #3 Silence Inhibit. Factory default is '0' for no silence inhibit; enter '1' to inhibit silencing of NAC #3 for one minute after an alarm. ❏ NAC #3 Autosilence feature which silences signals after a selected period. Factory default is '0' for no autosilence for NAC #3; enter '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; '6' for 30 minutes. 11 ❏ 12 NAC #3 Signal Coding. Factory default is '0' for steady (no coding); '1' for March Time code (120 PPM); '2' for California Time code (10 secs. On, 5 secs. Off); '3' for Temporal Time code (0.5 secs. On, 0.5 secs. Off, 0.5 secs. On, 0.5 secs Off, 0.5 secs. On, 1.5 secs. Off). ❏ NAC #4 Type Selection. Factory default is '0' for NAC #4 enabled (silenceable); enter '1' for enabled (nonsilenceable); '2' for disabled. 13 ❏ 14 NAC #4 Silence Inhibit. Factory default is '0' for no silence inhibit; enter '1' to inhibit silencing of NAC #3 for one minute after an alarm. ❏ NAC #4 Autosilence feature which silences signals after a selected period. Factory default is '0' for no autosilence for NAC #4; enter '1' for 5 minutes; '2' for 10 minutes; '3' for 15 minutes; '4' for 20 minutes; '5' for 25 minutes; '6' for 30 minutes. 15 ❏ 16 NAC #4 Signal Coding. Factory default is '0' for steady (no coding); '1' for March Time code (120 PPM); '2' for California Time code (10 secs. On, 5 secs. Off); '3' for Temporal Time code (0.5 secs. On, 0.5 secs. Off, 0.5 secs. On, 0.5 secs Off, 0.5 secs. On, 1.5 secs. Off). ❏ Canadian Supervisory Annunciation. Factory default is '0' for non-Canadian Supervisory Annunciation; enter '1' for Canadian Supervisory Annunciation. 17 116 Document #50193 Rev.D 5/2/97 P/N 50193:D Option Modules Programming Sheets Option Module Programming Reference Sheets Factory Defaults ---To enter Programming Level 3, press the MODE key, 7764, '3', [ENTER/STORE] 0 ❏ CAC-10F Class A Converter Card not installed. 0 ❏ LED-10IM EIA-485 Interface Module not installed. F 0 1 0 ❏ 1 ❏ 2 3 Maximum annunciator or ACM-8RF monitored address on EIA-485 line. 0 ❏ Printer not installed. 0 ❏ Printer Baud Rate. ('0' = 2400 Baud) 0 ❏ NAC/Relay Option Module not installed. 1 ❏ Programmable Relay #3 Definition. ('1' = supervisory). 4 ❏ Programmable Relay #4 Definition. ('4' = communication fail). 0 ❏ NAC #3 Type Selection. ('0' for NAC #3 enabled (silenceable). 4 5 6 7 8 9 0 ❏ NAC #3 Silence Inhibit. ('0' for no silence inhibit). 0 ❏ NAC #3 Autosilence feature which silences signals after a selected period. ('0' for no autosilence for NAC #3). 0 ❏ NAC #3 Signal Coding. ('0' for steady (no coding). 0 ❏ NAC #4 Type Selection. ('0' for NAC #4 enabled (silenceable). 0 ❏ NAC #4 Silence Inhibit. ('0' for no silence inhibit). 0 ❏ NAC #4 Autosilence feature which silences signals after a selected period. ('0' for no autosilence for NAC #4). 0 ❏ NAC #4 Signal Coding. ('0' for steady (no coding). 0 ❏ Non-Canadian Supervisory Annunciation. 10 11 12 13 14 15 16 17 Document #50193 Rev. D 5/2/97 P/N 50193:D 117 Upload/Download Program Sheets Upload/Download Program Sheets Appendix F ---To enter Programming Level 4, press the MODE key, 7764, '4', [ENTER/STORE] ❏ ❏ ❏ ❏ Panel Identification Number. Valid entries are 0 - F. ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Service Terminal #1 Phone Number. Addresses 4 - 19 store the phone number of Service Terminal #1. Enter 'F' to represent the end of the number. ❏ ❏ 20 21 Ring Count on Primary Phone Line. Enter number of rings prior to panel answering call. Valid entries are 0 - 25 (0 = no answer). Factory default is 25. ❏ FAX/Answer Machine, Primary Phone Line. Enter '0' for no sharing of phone line; '1' for sharing. ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ ❏ 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Service Terminal #2 Phone Number. Addresses 23 - 38 store the phone number of Service Terminal #2. Enter 'F' to represent the end of the number. ❏ ❏ Ring Count on Secondary Phone Line. Enter number of rings prior to panel answering call. Valid entries are 0 - 25 (0 = no answer). Factory default is 25. 39 ❏ ❏ 41 40 FAX/Answer Machine, Secondary Phone Line. Enter '0' for no sharing of phone line; '1' for sharing. Upload/Download Backup Reporting. Enter '0' for Upload/Download reports to go to the Secondary Central Station Phone Number on backup only; '1' for Upload/Download reports to always go to the Secondary; '2' for Upload/Download reports to go to the first available Central Station phone number. 42 Upload/Download Programming Reference Sheets Factory Defaults ---To enter Programming Level 4, press the MODE key, 7764, '4', [ENTER/STORE] 0 ❏ 0 ❏ 0 ❏ 0 ❏ 0 1 2 3 Panel Identification Number. F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F F F ❏ F ❏ ❏ ❏ 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Addresses 4 - 19 store the phone number of Service Terminal #1. Enter 'F' to represent the end of the number. 2 ❏ 5 ❏ Ring Count on Primary Phone Line. 0 FAX/Answer Machine, Primary Phone Line. ('0' for no sharing of phone line). ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ F ❏ 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Addresses 23 - 38 store the phone number of Service Terminal #2. Enter 'F' to represent the end of the number. 2 ❏ 5 ❏ Ring Count on Secondary Phone Line. 0 FAX/Answer Machine, Secondary Phone Line. Enter '0' for no sharing of phone line; '1' for sharing. ❏ 0 Upload/Download Backup Reporting. ('0' for Upload/Download reports to go to the Secondary Central Station ❏ 39 40 41 42 Phone Number on backup only). 118 Document #50193 Rev.D 5/2/97 P/N 50193:D Wire Requirements Appendix G Wire Requirements Connecting external system accessories to the MS-5210UD main circuits must be carefully considered to ensure proper operation. It is important to use the correct type of wire, wire gauge and wire run length per each MS-5210UD circuit. Reference the chart below to specify wire requirements and limitations for each MS-5210UD. TABLE 6-1: Wire Requirements CIRCUIT CONNECTIONS CIRCUIT TYPE WIRE REQUIREMENTS CIRCUIT WIRE TYPE AND FUNCTION LIMITATIONS RECOMMENDED MAX. DISTANCE WIRE GUAGE (FEET) 12 AWG (3.25 mm2) Belden 9583 WPW999 10,000 (3,000 m) Initiating Device Circuit (power-limited) Connects to Initiating Devices Untwisted, unshielded wire 8,000 (2,400 m) (Do not exceed 100 ohms) 4,875 (1,480 m) 3,225 (975 m) 14 AWG (2.00 mm2) Belden 9581 WPW995 16 AWG (1.30 mm2) Belden 9575 WPW991 18 AWG (0.75 mm2) Belden 9574 WPW975 EIA-485 LED-10IM Interface Module (power-limited) EIA-232 (power-limited) 24 VDC Regulated, resettable, nonresettable (power-limited) Connects to annunciator modules and relay module Twisted, shielded pair with a characteristic impedance of 120 ohms 6,000 (1,800 m) 18 AWG (0.75 mm2) PRT-24 output connects to remote printer and PC computer Twisted, shielded pair 50 (15 m) 18 AWG (0.75 mm2) minimum Connects to annunciators and other accessories No more than 1.2 volt drop allowed from supply source to end of any branch Distance limitation set by 1.2 volt maximum line drop 12 AWG (3.25 mm2) - 18 AWG Document #50193 Rev. D 5/2/97 P/N 50193:D (0.75 mm2) 119 Operation and Function Modes Appendix H TABLE 6-2: OPERATION MODES CODE ACTIVITY NOTES 6676 (NORM) Returns to normal operation Fire protection on 7764 (PROG) Enters Program Mode 4 levels of programming may be entered. Fire protection is off. May select silent or audible walktest function. 9255 (WALK) Enters Walktest Mode 4478 (HIST) View History File 8768 (TROU) Activates internal system voltmeter for troubleshooting and diagnosing problems Fire protection is off while voltmeter function is enabled. 7746 (PRIN) Sends status, history file, walktest file, troubleshoot voltages and entire programming selections to printer. Fire protection is on. Requires PRT-24 option module. 5267 (LAMP) Turns on all LEDs on the main PCB and all system annunciators for 5 seconds Fire protection is on. 3696 (DOWN) Allows for downloading the entire program file to the panel TABLE 6-3: 120 Operation and Function Modes Fire protection is off. Use display or printer to view History File. Fire protection is on. Must have service terminal ready. Fire protection remains on. FUNCTION MODES CODE ACTIVITY NOTES 3472 (DISA) Allows disabling of any input zone or NAC 3622 (ENAB) Allows enabling (return to normal) of any zone or NAC May only enable one NAC or zone at a time. 3745 (DRIL) Performs drill function by turning on all NAC outputs Transmission of drill function to central station is defaulted to ON. 3337 (DEFP) Reprograms all entries for Program Levels 1 through 4 to the original factory default settings Entry of code must be performed two times in rapid succession as a safety feature. Use caution when using this feature. Document #50193 May only disable one NAC or zone at a time. Places system into trouble. Rev.D 5/2/97 P/N 50193:D Notes Document #50193 Rev. D 5/2/97 P/N 50193:D 121 Notes 122 Document #50193 Rev.D 5/2/97 P/N 50193:D Notes Document #50193 Rev. D 5/2/97 P/N 50193:D 123 Limited Warranty Fire-Lite® warrants its products to be free from defects in materials and workmanship for eighteen (18) months from the date of manufacture, under normal use and service. Products are date stamped at time of manufacture. The sole and exclusive obligation of Fire-Lite® is to repair or replace, at its option, free of charge for parts and labor, any part which is defective in materials or workmanship under normal use and service. For products not under Fire-Lite® manufacturing date-stamp control, the warranty is eighteen (18) months from date of original purchase by Fire-Lite®'s distributor unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. This warranty is void if the product is altered, repaired or serviced by anyone other than Fire-Lite® or its authorized distributors or if there is a failure to maintain the products and systems in which they operate in a proper and workable manner. In case of defect, secure a Return Material Authorization form from our customer service department. Return product, transportation prepaid, to Fire-Lite®, 12 Clintonville Road, Northford, Connecticut 06472-1653. This writing constitutes the only warranty made by Fire-Lite® with respect to its products. Fire-Lite® does not represent that its products will prevent any loss by fire or otherwise, or that its products will in all cases provide the protection for which they are installed or intended. Buyer acknowledges that Fire-Lite® is not an insurer and assumes no risk for loss or damages or the cost of any inconvenience, transportation, damage, misuse, abuse, accident or similar incident. Fire-Lite ® GIVES NO WARRANTY, EXPRESSED OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. UNDER NO CIRCUMSTANCES SHALL Fire-Lite® BE LIABLE FOR ANY LOSS OF OR DAMAGE TO PROPERTY, DIRECT, INCIDENTAL OR CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR INABILITY TO USE Fire-Lite® PRODUCTS. FURTHERMORE, Fire-Lite® SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF, OR AS A RESULT OF, PERSONAL, COMMERCIAL OR INDUSTRIAL USE OF ITS PRODUCTS. This warranty replaces all previous warranties and is the only warranty made by FireLite®. No increase or alteration, written or verbal, of the obligation of this warranty is authorized. "Fire-Lite" is a registered trademark. 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Technical Publishing Document WARFBG-C.PM6 04/02/96
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 1999:01:06 09:13:38 Producer : Acrobat Distiller 3.01 for Windows Author : Mark Leuck Title : F5210c.pdf Modify Date : 1999:01:06 09:14:30 Page Count : 124 Page Mode : UseThumbsEXIF Metadata provided by EXIF.tools