12 - 32 Station PDS™ Control
Installation and Operators Manual

March 2004

MW1812A

Chore-Time Warranty

12 - 32 Station PDS™ Control

Chore-Time Warranty
Chore-Time Equipment (“Chore-Time”) warrants each new Chore-Time product manufactured by it to be free
from defects in material or workmanship for one year from and after the date of initial installation by or for the
original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the
Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of
manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or
replacement. Labor costs associated with the replacement or repair of the product are not covered by the
Manufacturer.

Conditions and Limitations
1. The product must be installed by and operated in accordance with the instructions published by the
Manufacturer or Warranty will be void.
2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer.
3. This product must be purchased from and installed by an authorized distributor or certified representative
thereof or the Warranty will be void.
4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper
maintenance shall not be considered defects under the Warranty.
5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry
or commerce are not covered by this Warranty.
The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer
or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein
include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders,
lost income, increased overhead, labor and incidental costs and operational inefficiencies.
THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND
THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO
MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR
QUALITY OF THE PRODUCT FURNISHED HEREUNDER.
Chore-Time Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any
manner or to offer or grant any other warranties for Chore-Time products in addition to those terms expressly
stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer
reserves the right to change models and specifications at any time without notice or obligation to improve previous
models.
Effective: March 2004
Chore-Time Equipment
E-mail P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (877) 730-8825
E-mail: poultry@choretime.com • Internet: http//www.choretime.com

Thank You
The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a

problem should arise, your Chore-Time distributor can supply the necessary information to help you.

1

MW1812A

Contents
Topic

Page

Chore-Time Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
About This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Follow Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Decal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DANGER: Electrical Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Support Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

General Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
The System Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cage System Layout Under 600’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cage System Layout Over 600’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Broiler System Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiple House Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5
6
6

Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Hunter® Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chore-Tronics™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Compressed Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Water Column Gauge Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Air Leak Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Flushing The System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Flushing Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
When to flush the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Flushing for Sediment, Air Locks, and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Flushing After Introduction of Water Treatment or Bird Health Products . . . . . . . . . . . . . . . . . . . . . .13
Flush to Stimulate Birds to Drink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Parts Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

MW1812A

2

About This Manual

12 - 32 Station PDS™ Control

About This Manual
The intent of this manual is to help you in two ways. One is to follow step-by-step in the order of assembly of your
product. The other way is for easy reference if you have questions in a particular area.

Important:
Important:

Read ALL instructions carefully before starting construction.
Pay particular attention to all SAFETY information.

• Metric measurements are shown in millimeters and in brackets, unless otherwise specified. “ “ ” equals inches
and “' ” equals feet in English measurements.
Examples:
1" [25.4]
4' [1 219]
• Optional equipment contains necessary instructions for assembly or operation.
• Very small numbers near an illustration (i.e., 1257-48) are identification of the graphic, not a part number.

Safety Information
Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous
situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or
damaged safety decals immediately.
Using the equipment for purposes other than specified in this manual may cause personal injury and/or damage to
the equipment.

Safety–Alert Symbol
This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the
potential for personal injury. This equipment is designed to be installed and operated as safely
as possible...however, hazards do exist.

Understanding Signal Words
Signal words are used in conjunction with the safety–alert symbol to identify the severity of the warning.
DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or
serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or
serious injury.
CAUTION indicates a hazardous situation which, if not avoided, MAY result in minor or moderate
injury.

3

MW1812A

12 - 32 Station PDS™ Control

Safety Instructions

Safety Instructions
Follow Safety Instructions
Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended
precautions and safe operating practices.
Keep safety signs in good condition. Replace missing or damaged safety signs.

Decal Descriptions
DANGER: Electrical Hazard
Disconnect electrical power before inspecting or servicing equipment
unless maintenance instructions specifically state otherwise.
Ground all electrical equipment for safety.
All electrical wiring must be done by a qualified electrician in accordance
with local and national electric codes.
Ground all non-current carrying metal parts to guard against electrical
shock.
With the exception of motor overload protection, electrical disconnects and
over current protection are not supplied with the equipment.

General
Support Information
The Chore-Time 12-32 Station Pneumatic Drinking System (PDS™) Control is designed to control water line
regulators in a Chore-Time Nipple Watering System. Using this equipment for any other purpose or in a way not
within the operating recommendations specified in this manual will void the warranty and may cause personal
injury.
This manual is designed to provide comprehensive planning and installation information. The Table of Contents
provides a convenient overview of the information in this manual.

General Installation Information
Please read the installation instructions in this manual prior to beginning the installation. This manual provides
the necessary information on the installation, operation and maintenance of the Chore-Time watering equipment
you have purchased.
The 12-32 Station PDS™ Control is available in station increments of 4(ie. 12, 16, 20...). Each station is capable
of controlling up to 2 individual Volumatic™ regulators. For example a 12 station control can regulate and flush
up to 24 individual regulators.
Compressed air must be available and regulated between 6 and 12 psi [41.37 and 68.95 kPa]. Each PDS™ control
consumes a low volume of air. Therefore, one centrally located compressor with a holding tank can easily supply
enough air for multiple PDS™ controls.

MW1812A

4

Below are examples of the Chore-Time Nipple Watering system layouts. These are to be used to show different methods for installing the PDS™ system. Refer
to Parts List Section, page 15 for item part numbers.

Cage System Layout Under 600’

The System Layout

5

The System Layout

Note: 1 regulator per tier
for both lines.

PATENT NO.
5,967,167
6,240,956
6,253,708
INCOMING PRESSURE
12 psi MAX
(82.74 kPa)

CHORE-TIME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD, INDI ANA 46542-2000

Warrant y is void if cover
is not kept closed.

PDS™ CONTROL
Pneumatic Drinking System

ADJUSTMENT
KNOB
INCREASE +

DECREASE
LABEL NO.
2529-812

Figure 1. (6 Row 5 High Cages)

Cage System Layout Over 600’
Note: 1 regulator
for each line.

INCOMING PRESSURE
12 psi MAX
(82.74 kPa)

CHORE-TIME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD , IND IANA 46542-2000

Warranty is void if cover
is not kept closed.

PDS™ CONTROL
Pneumatic Drinking System

ADJUSTMENT
KNOB
INCREASE +

DECREASE
LABEL N O.
2529-812

MW1812A

Figure 2. (3 Row 5 High Cages)

12 - 32 Station PDS™ Control

PATENT NO.
5,967,167
6,240,956
6,253,708

12 - 32 Station PDS™ Control

MW1812A

Broiler System Layout

PATENT NO.
5,967,167
6,240,956
6,253,708
INCOMI NG PRESSURE
12 psi MAX
(82.74 kPa)

CHORE-TI ME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD, INDIANA 46542-2000

Warranty is void if cover
is not kept closed.

PDS™ CONTROL
Pneumatic Drinking System

ADJUSTMENT
KNOB
INCREASE +

DECREASE
LABEL NO.
2529-812

Figure 3. Broiler Layout

Multiple House Layout

PAT ENT NO.
5,967,167
6,240,956
6,253,708

PATENT NO.
5,967 ,167
6,240 ,956
6,253 ,708

PATENT NO.
5,967,167
6,240,956
6,253,708

INCOMING PRESSURE
12 psi MAX
(82.74 kPa)

INC OMING PRESSURE
12 psi MAX
(82.7 4 kPa)

CHORE-T IME EQ UIPMENT

CHORE-T IME EQ UIPMENT

A D IVI SI ON OFC TB I NC.
MI LFORD , IND IAN A 46542-2000

A D I VIS ION OF CTB INC .
MILFORD , IN DI ANA 46542-2000

A DI VI SION OFC TB IN C.
MILFOR D, IN DI ANA 46542-2000

Warra nty is void if cover
is not kept closed.

A D IV ISI ON OF CTB INC.
MI LFORD , IND IAN A 46542-2000

Warranty is void if cover
is not kept closed.

PDS™ CONTROL

Pneumatic Drinking System

INCREASE +
LABEL N O.
2529-812

PDS™ CONTROL

Pneumatic Drinking System

ADJUSTMENT
KNOB
DECREASE

Warra nty is void if cover
is not kept closed.

PDS™ CONTROL

Pneumatic Drinking System

ADJUSTMENT
KNOB

INCOMING PRESSURE
12 psi MAX
(82.74 kPa)

CHO RE -T IME EQUIPMENT

Warranty is void if cover
is not kept closed.

PDS™ CONTROL

INCREASE +

PAT ENT NO.
5,967,167
6,240,956
6,253,708

INCOMING PRESSURE
12 psi MAX
(82.7 4 kPa)

CHORE-TIME EQUIPMENT

Pneumatic Drinking System

ADJUSTMENT
KNOB
DECREASE

INCREASE +
LABEL N O.
2529-812

ADJUSTMENT
KNOB
DECREASE

INCREASE +
LAB EL NO.
2529-812

DECREASE
LABEL N O.
2529-812

Figure 4. (4 House Layout)

6

The System Layout

Air can be run from a central location to supply multiple houses. Air lines can consist of Chore-Time Red tubing (Part No. 45895-500), which will supply a
sufficient air supply, or PVC plumbing.

Installation

12 - 32 Station PDS™ Control

Installation
Locate the control in a convenient location where it can easily be seen and adjusted.
Fasten the control to the wall through the four holes in the corners (mounting hardware not supplied). It is
recommended to use #10 flat head wood screws as mounting hardware.
Connect the PDS control and the Hunter control together with liquid tight connectors and conduit (not supplied),
to allow wires to be run between the controls.

Figure 5. Mounting orientation

Hunter® Control
Caution: Be sure power to the control is still disconnected and no backup battery is
installed!
Install the modules to the Hunter® Control according to the Hunter installation manual.

Wiring
Wire from the circuit breaker to the Hunter control for 120V
•Ground to green wire
•Neutral to blue wire
•120V to black wire
•Brown wire to be capped
Wire from circuit breaker to Hunter control for 240V
•Ground to green wire
•Neutral to blue wire
•240V to blue and brown wires
•Black wire to be capped
With power off to the control connect with 18AWG minimum. Start wiring from any C (common) on Hunter
control then run wires through the conduit to C (common) on the PDS control. Run wire from 1 on Hunter control
to 1 on the PDS control. Continue running wires so the numbered connection in the Hunter control matches the
numbered connection in the PDS control, see figure 6.

Chore-Tronics™
When using Chore-Tronics™ to monitor water consumption, flush water can be automatically subtracted from
the water usage through the meter. To do this connect one wire to common and one wire to P/MV both in
the Hunter control. Run these two wires to a 24VAC Coil Relay (not supplied), from the relay run the two
wires to the Chore-Tronics control, see figure 7.

7

MW1812A

12 - 32 Station PDS™ Control

Installation

Connect Wires With Corresponding Numbers

C
P/MV
SEN

Common Wire Connections

SEN
TEST
REM
AC
AC
GND

Incoming Air Pressure
Regulator Air Pressure
1812-12 12/03

Water Column Pressure

Figure 6. Hunter/PDS Wiring
HUNTER CONTROL

C
P/MV
SEN

24VAC COIL RELAY
(NOT SUPPLIED)

SEN
TEST
REM
AC
AC
GND

OPTIONAL
SECOND I/O BOARD
MODEL 32/40 ONLY

1812-14 2/04

CHORE-TRONICS
CONTROL

Figure 7. Hunter/Chore-Tronics Wiring

Figure 8. Internal Wiring
MW1812A

8

Installation

12 - 32 Station PDS™ Control

Tubing
Route the regulator tubing so any condensation in
the air lines will not run into the control. Allow slack
in the regulator tube leads so that they can be
pinched for maintenance and diagnostic purposes,
see figure 9.
Each regulator tubing lead may be used to supply air
to two nipple line regulator inlets. This will assure
enough flush water volume per line to move air and
sediment down the nipple lines and out. Run each air
supply tube across the ceiling and down the water
supply hose to each of the regulators, attaching it to
the provided hose barb on the bottom of each
regulator, see figure 10. Warming the end of the
tubing will aid in installation.

Incoming Air

Regulator Tubing Lead

Figure 9. Regulator Tube Leads

Caution: Over-Heating of tube end can cause
distortion and leaking.
Air Supply Tube

Compressed Air Supply

Figure 10. Air Supply Routing

Turn the red adjustment knob clockwise (Decrease) until the knob stops turning, see figure 13.
BEFORE connecting the compressed air supply to the control, the compressed air supplied to the PDS™
control, must be regulated between 6 and 12 psi [41.37 and 68.95 kPa]. Failure to do this will result in
damage to the gauges and possibly other components. After the air supplied from the compressor is confirmed
to be between 6 and 12 psi [41.37 and 68.95 kPa], connect the air supply to the incoming pressure line on the PDS
control, see figure 9.
The PDS Control has an air pressure gauge to monitor the incoming air
pressure. Under normal operating conditions, this gauge should show between
6 and 12 psi [41.37 and 68.95 kPa] of air pressure.

Figure 11. Air Pressure

9

MW1812A

12 - 32 Station PDS™ Control

Installation

Water Column Gauge Calibration
Turn the red adjustment knob counter-clockwise (increase) until the water column gauge reads 8 inches, see figure
13.
After installation of the PDS regulators make sure all the water lines are flushed and charged. Then measure the
water column at one of the Volumatic™ regulators and confirm 8 inches of water column. If anything other than
8 inches is measured at the stand tube, the water column gage will need to be re-calibrated to that measurement.
To re-calibrate the water column gauge remove the plastic
cover with a small screwdriver. Then turn the calibration
screw (see figure 12.) until the gauge reads the correct water
column height. Replace the plastic cover on the gauge.

Air Leak Test

Calibration
Screw

Figure 12. Water Column

Check each control and house for air leaks with the water column gauge at 8". To check for air leaks in the control
or the house pinch the incoming air supply tube to shut off the incoming air pressure. Watch the air pressure gauge
on the control, the gauge should not drop any more than 2 psi [13.79 kPa] in 1 minute. If the air pressure does drop
faster than 2 psi [13.79 kPa] in 1 minute, refer to the trouble shooting section on page 14. Repeat this procedure
for every PDS control.

MW1812A

10

Operation

12 - 32 Station PDS™ Control

Operation
Adjusting the water column height in the individual stand
tubes. To adjust the water column height turn the red
adjustment knob counter-clockwise to increase and clock-wise
to decrease (see figure 13.) until the water column gauge reads
the desired water column height.

Note: Individual PDS Volumatic regulators provide a
minimum water column height in
case air pressure is lost. The
regulators CAN NOT be adjusted
below this height regardless of the
water column gauge reading.

Figure 13. Adjusting the water column

Flushing The System
Refer to the Hunter Control manual for specific programing details.
The Hunter control has the capacity to have
four individual programs: "A", "B", "C" and
"D". Only programs "A", "B" or "C" should
be used to control the PDS unit. Once a
station is programmed to run on program
"A", "B" or "C" it can’t be assigned to run in
program "D".
Single stations or all stations may be
manually flushed at any time. Refer to
Programming the Controller section in the
Hunter control manual.
When birds go out it is a good idea to turn
the Hunter control to the off position and
turn the adjustment knob on the PDS control
to the minimum setting.
Each program can have up to eight daily
start times. As long as there are start times
Figure 14. Operating the control
entered for stations in a particular program
that program will run. To maintain multiple programs in the control without all of them running, all the start times
in the undesired programs must be set to off. The unused programs (except the start times) are retained but will
not run until the start times are re-entered. This allows you to program one, two or three separate flushing
sequences. For example, one for summer and one for winter or one for brooding and one for finishing.
Each station can be set to run from a minimum of 1 minute to a maximum of 2 hours in 1 minute intervals. The
actual amount of time it takes to completely change the water in a 3/4" drinker line is dependent on the flow rate
through the line. This flow rate can easily be estimated by putting the regulator into flush and timing how long it
takes to fill a container of known volume at the drain end of the line. Once this time is determined use the formula
below to calculate the flow rate in gallons or liters per minute and then refer to the charts on page 12 to determine
the estimated flush time in minutes for your specific line length.
Volume of Container (Gallons or Liters)
Seconds to Fill Container Divided by 60

=

Flow Rate in Gallons or Liters per Minute

For example, if it takes 185 seconds to fill a 5 gallon container the resulting flow rate would be 1.6 GMP.
5 Gallons
185/60

11

=

5
308

=

1.6 Gallons per Minute.

MW1812A

12 - 32 Station PDS™ Control

Flushing The System

Minutes to Flush and Total Line Capacity
for Chore-Time Nipple Systems

Gallons per Minute
Flow Rate

Water Line Length in Feet
100’

200’

300’

400’

500’

600’

700’

800’

1

3.4

6.8

10.2

13.6

17.0

20.4

23.8

27.2

2

1.7

3.4

5.1

6.8

8.5

10.2

11.9

13.6

3

1.1

2.3

3.4

4.5

5.7

6.8

7.9

9.1

4

0.9

1.7

2.6

3.4

4.3

5.1

6.0

6.8

5

0.7

1.4

2.0

2.7

3.4

4.1

4.8

5.4

6

0.6

1.1

1.7

2.3

2.8

3.4

4.0

4.5

7

0.5

1.0

1.5

1.9

2.4

2.9

3.4

3.9

8

0.4

0.9

1.3

1.7

2.1

2.6

3.0

3.4

Total Line
Capacity
20.4
Gallons

Total Line
Capacity
23.8
Gallons

Total Line
Capacity
27.2
Gallons

180m

210m

240m

Estimated Flush Time in Minutes
Total Line
Capacity
3.4
Gallons

Total Line
Capacity
6.8
Gallons

Total Line
Capacity
10.2
Gallons

Total Line
Capacity
13.6
Gallons

Total Line
Capacity
17.0
Gallons

Gallons of water in one foot of 3/4" Chore-Time water pipe=.034

Liters Per Minute
Flow Rate

Water Line Length in Meters
30m

60m

90m

120m

150m

4

3.2

6.3

9.5

12.7

15.8

19.0

22.2

25.3

6

2.1

4.2

6.3

8.4

10.6

12.7

14.8

16.9

8

1.6

3.2

4.7

6.3

7.9

9.5

11.1

12.7

10

1.3

2.5

3.8

5.1

6.3

7.6

8.9

10.1

12

1.1

2.1

3.2

4.2

5.3

6.3

7.4

8.4

14

0.9

1.8

2.7

3.6

4.5

5.4

6.3

7.2

16

0.8

1.6

2.4

3.2

4.0

4.7

5.5

6.3

18

0.7

1.4

2.1

2.8

3.5

4.2

4.9

5.6

20

0.6

1.3

1.9

2.5

3.2

3.8

4.4

5.1

22

0.6

1.2

1.7

2.3

2.9

3.5

4.0

4.6

24

0.5

1.1

1.6

2.1

2.6

3.2

3.7

4.2

26

0.5

1.0

1.5

1.9

2.4

2.9

3.4

3.9

28

0.5

0.9

1.4

1.8

2.3

2.7

3.2

3.6

30

0.4

0.8

1.3

1.7

2.1

2.5

3.0

3.4

Total
Line
Capacity
12.7
Liters

Total
Line
Capacity
25.3
Liters

Total
Line
Capacity
38.0
Liters

Total
Line
Capacity
76.0
Liters

Total
Line
Capacity
88.6
Liters

Total
Line
Capacity
101.3
Liters

Estimated Flush Time in Minutes
Total
Line
Capacity
50.6
Liters

Total
Line
Capacity
63.3
Liters

Liters of water in one meter of 3/4" (1.90 cm) Chore-Time water pipe=.422
Estimated flush times above are to completely exchange the water in the pipe. The flush time to stimulate bird
drinking may be less, depending on the frequency of flushes.

MW1812A

12

Flushing Recommendations

12 - 32 Station PDS™ Control

Flushing Recommendations
Multiple House Application:
Well capacity typically limits the number of water lines that can be flushed at one time. Flushing should be
staggered so 2 lines per well supply are flushed at the same time.

When to flush the system
Single stations or all stations may be manually flushed at any time. Refer to Programming the Controller section
in the Hunter Control manual.

Flushing for Sediment, Air Locks, and Cleaning
Start by flushing several times per flock. Watch the water coming out of the ends of the water lines. If the water
is clean with little or no air you can flush less often. If the water is discolored and has sediment or large
amounts of air you may want to flush more often until these problems disappear. The sediments could react
with medications, vaccines, and electrolytes. They will also hamper the effects of disinfectants and cleaners
(chlorine and acids).

Flushing After Introduction of Water Treatment or Bird Health Products
After running any type of medication, disinfectant, electrolyte, vitamin, or vaccine, see the chart on page 12 for
estimated flush times. Some products or treatments may require longer flushing time to be completely
removed from the water lines.

Flush to Stimulate Birds to Drink
1. In periods of hot weather flushing will provide cool, fresh water.
2. As birds mature, additional flushing can stimulate the birds to drink more water.

Maintenance
Keep the control box lid closed. The control is not capable of operating in a dusty environment. The loading
regulator vents into the control box. When the control box is sealed the positive internal air pressure keeps dust out

13

MW1812A

12 - 32 Station PDS™ Control

Troubleshooting

.

Troubleshooting
Problem
No water in Regulator Stand Tube.

Water Column does not change on a Regulator.
Water Column to top of Stand Tube.

Compressor suddenly runs more often than
normal.

House seems to leak or lose compressed air too
quickly.

Control unit leaks compressed air.

Regulators do not adjust to the same level.

Correction
1. Water Off.
2. Defective or plugged Regulator.
3. Regulator plumbed backwards.
1. Stand Tube Cap plugged (not venting).
2. Air line to Regulator pinched.
1. Regulator seat worn.
2. Stand Tube Cap plugged.
3. Air Loading Unit putting out too high pressure (defective solenoid).
1. Shut off or pinch off all lines going to the individual controls to find
which house is the problem.
2. Open one line at a time until you find one that causes the compressor
tank to lose air more quickly.
3. See correction for house leak below.
1. Shut off the incoming line to the control and watch the small
INCOMING PRESSURE GAUGE. If the control holds pressure, the
leak is between the air source and that house.
2. With the incoming air off and the gauge indicates that there is a 2
PSI drop or more within 1 minute, the problem is in the control, lines,
or regulators.
3. Shut off or pinch off all lines going out to the regulators and the
incoming line. If the control loses pressure, the problem is inside the
control. See control unit leak below.
4. If the unit holds pressure, release one line at a time to isolate the
cause of the leak.
5. Test line connections and regulator for leaks.
1. Check the vent hole in the red cover of the Air Loading Unit, see
figure 15. Put soapy water over the hole. A small amount of air
coming out is normal (bubble should grow slowly over several
seconds).
2. Put soapy water on all internal hose connections to find leak.
Water in some of the air lines. Drain hose and check for defective
Regulator Diaphragm. This is done by pinching the hose off at the
nipple line regulator and if there is no leak the water column will
remain constant, if the regulator has a leak the water column will
decrease.

Vent Hole
Adjustment
Knob

Figure 15. Vent Hole

MW1812A

14

Parts Listing

15

Parts Listing
PDS™ Control (part no.’s: 46772-12, 46772-16, 46772-20, 46772-24, 46772-28, 46772-32)

15

WIRING AND TUBING
REMOVED FOR CLARITY.

13

14

10

12
11

PATENT NO.
5,967,167
6,240,956
6,253,708
INCOMING PRESSURE
12 psi MAX
(82.74 kPa)

9

CHORE-TIME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD, INDIANA 46542-2000

Warranty is void if cover
is not kept closed.

INCOMING PRESSURE
6-12 psi
(41.37- 68.95 kPa)

8

PDS™ CONTROL
Pneumatic Drinking System

ADJUSTMENT
KNOB
INCREASE +

DECREASE
LABEL NO.
2529-812

16
14

17

5

4
6

13

3

17

7

18
2

20

1

MW1812A

12 - 32 Station PDS™ Control

19

23

22

12 - 32 Station PDS™ Control

MW1812A

21

Item
Description
Part No.
1
Control Box
48583
2
Lower PDS Plate
46333-1
3
Diaphragm
35891
4
8 Station Airloader
44452
5
4 Station Airloader
44451
6
8 Station Airloader W/Knob
48584
7
Seal
34767
8
Flexible Hose
48574
9
Caplug
48588
10
Control Box Lid
42683
11
Control Box Latch
30862
12
Control Box Latch Pivot
30863
13
PSI Gauge
48585
14
Water Column Gauge
44029
15
Panel Hinge
41016
16
PDS Control Decal
2529-812
17
Front Plate
46334-1
18
Neoprene Washer
2955-59
19
Washer
2499
20
Hose Adapter
48586
**21
8 Station Hunter Control
46771-8
**22
4 Station Module
46773-4
**23
8 Station Module
46773-8

**These components are individually boxed.
Contact your nearby Chore-Time distributor
or representative for additional Hunter
Control parts and information.

Parts Listing

16

Made to work.
Built to last.

Contact your nearby Chore-Time distributor or representative for additional parts and information.

CTB Inc.
P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (800) 333-4191
E-mail: poultry@choretime.com • Internet: http//www.choretime.com

Printed in the U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2004:03:02 13:44:35Z
Create Date                     : 2004:03:02 13:44:35Z
Page Count                      : 18
Creation Date                   : 2004:03:02 13:44:35Z
Mod Date                        : 2004:03:02 13:44:35Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : ncripe
Metadata Date                   : 2004:03:02 13:44:35Z
Creator                         : ncripe
Title                           : MW1812.book
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu