MS6252B通用说明书 Mastech MS 6252B Digital Anemometer Manual
User Manual: Mastech-MS-6252B-Digital-Anemometer-Manual
Open the PDF directly: View PDF
.
Page Count: 10
| Download | |
| Open PDF In Browser | View PDF |
MS6252B Digital Anemometer Operation Manual °C °F DP WB MAX MIN % RH VEL FLOW AREA USB m2 ft 2 x10 FPM CMM knots ft/s ft/m CFM CMS m/s km/h ml/h MS6252B Digital Anemometer FUNC MAX MIN UNIT HOLE MODE USB CONTENTS CONTENTS 1. Safety Information...........................1 4. Operating Guidance.........................11 1.1 Preparation........................................1 4.1 Power On/Off...................................11 1.2 Usage................................................1 4.2 Reading hold ...................................11 1.3 Marking.............................................1 4.3 Backlight function.............................12 1.4 Maintenance......................................2 4.4 Wind speed measurement................12 4.5 Wind speed unit selection.................13 2. Description..........................................3 2.1 Part name..........................................3 2.2 Button description..............................6 2.3 Sign definition....................................7 4.6 Area setting......................................13 4.7 Air volume measurement..................13 4.8 Air volume unit selection...................14 4.9 Temperature unit selection................14 3. Specification......................................8 4.10 Temperature mode selection...........14 3.1 General.............................................8 4.11 USB real time data uploading..........14 3.2 Technique data.................................9 4.12 Use tripod connection receptacle.....15 4.13 Replace battery...............................16 5. Attachments............................................16 2. DESCRIPTION FRONT PANEL -This meter is a digital anemometer for measuring the ambient temperature, humidity, dew point temperature, wet bulb temperature, wind speed, and air volume. -This meter is a portable, professional measuring instrument with large-screen LCD and backlight, multi-unit switching functions. -This meter can be used for hand-held or fixed measurement. -This meter has the functions of reading hold, maximum, minimum, etc. -It has a low battery indicator and USB real time data uploading functions. 2.1 Part name 1 2 (1) Fan (2) LCD (3) “FUN” — Function switching button (4) “ ”— Power switch (5) “UNIT” — Unit switching button (6) Maximum/Minimum button (7) “HOLD/MODE” hold display, switch temperature mode (8) “ /USB” — Backlight/USB real time data uploading functions (9) Fan retaining bolt hole (10) Connection hole for fixing measurement bracket (11) Battery housing cover retaining bolt hole (12) Battery cover 03 °C °F DP WB 3 4 5 6 MAX MIN % RH VEL FLOW AREA USB m2 ft 2 x10 7 FPM CMM knots ft/s ft/m CFM CMS m/s km/h ml/h 8 MS6252B Digital Anemometer FUNC MAX MIN UNIT 04 HOLE MODE USB 2.3 Sign definition 3. SPECIFICATION Indicates Auto Power-Off status H Reading hold state VEL Wind speed measurement state FLOW Air volume measurement state AREA Area setting required by air volume DP Indicates that the current mode is dew point temperature mode WB Indicates that the current mode is wet bulb temperature mode °C, °F Temperature unit %RH Relative humidity sign USB Indicates that USB real time data uploading is enabled MAX Displays maximum after entering maximum/minimum mode MIN Displays minimum after entering maximum/minimum mode m² Indicates that the current area setting unit is square meter ft² Indicates that the current area setting unit is square foot CMM Cubic meters per minute CMS Cubic meters per second CFM Cubic meters per minute knots Nautical miles per hour, 1850 meters per hour ft/s Feet per second ft/m Feet per minute m/s Meters per second Km/h Kilometers per hour mil/h Nautical miles per hour Low battery indicator The meter should be recalibrated under the condition of 18°C~28°C, relative humidity <75% every year. 07 3.1 General 3.1.1 Work height: Maximum 2000m 3.1.2 Work mode: Frequency of wind speed conversion 3.1.3 Display: LCD 3.1.4 Maximum show value: 9999 3.1.5 Sampling time: About 0.4s/time. 3.1.6 Low battery indicator: sign displays on LCD. 3.1.7 Work power: 1×9V 6F22 battery. 3.1.8 Operation environment: Relative humidity–0~85%RH, no moisture condensation Temperature–0°C~40°C, no moisture condensation 3.1.9 Detector (fan) operation environment: Relative humidity– 0~95%RH, no moisture condensation. Temperature–-20°C~80°C, no moisture condensation. 3.1.10 Storage environment: Relative humidity– 0~80%RH, no moisture condensation Temperature–-10°C~50°C, no moisture condensation 3.1.11 Dimension: Meter –165LX85 WX38Hmm. 3.1.12 Weight: About 200g 08 enable the USB function of the meter. 5.The PC software displays data and diagrams. 6. Save or print data. ONLINE 4.13 Replacing battery 4.13.1 If the “ ”sign appears, this indicates that the battery should be replaced. 4.13.2 Power off the meter and remove the battery cover. 4.13.3 Replace the old battery. 4.13.4 Install the battery cover properly. 5. ATTACHMENTS (1) Battery 9V, NEDA 1604, 6F22 1pc (2) Detector Bracket Optional (3) Packaging Bag 1pc (4) Operation Manual 1pc (5) CD 1pc 4.12 Using tripod connection receptacle 4.12.1 When necessary, the meter can be fixed on a tripod. 4.12.2 When necessary, the meter can be used by hang. 15 16 HYS006709
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 10 Create Date : 2015:09:11 14:10:17+08:00 Modify Date : 2015:09:11 14:10:17+08:00 Producer : Corel PDF Engine Version 17.1.0.572 Author : Administrator Creator : CorelDRAW X7 Title : MS6252B通用说明书.cdrEXIF Metadata provided by EXIF.tools