Portable Data Logger OM SQ2040 Series
User Manual: OM-SQ2040 Series
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Portable Data Logger OM-SQ2040 U 16 True Differential or 32 Single-Ended Universal Analog Inputs for Voltage, Current or Resistance Measurements—Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs U Analog Inputs Can Be Used with Thermistors, Thermocouples, 2, 3 or 4-Wire RTD Temperature Sensors and 4 to 20 mA Signals U User Selectable Logging Rates of Up to 100 Hz on Up to 4 Channels U Download of Internal Data to Removable MMC/SD (Multi Media Card/Secure Digital) Memory U Large Non-Volatile Internal Memory—Data Retention is Virtually Indefinite U Ethernet, Wi-FI (On the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 Communication Ports U Sensor Power and FET Input Connections Alarm Outputs For Use The OM-SQ2040-2F16 data logger With External Devices has two analog to digital converters (A/D’s) which increases logging U Easy Access to Information flexibility over the OM-2020-1F8 Using the 2 Line, 20 Character model. The first corresponds to LCD and Push Button Panel inputs on blocks A, B, C and D and U Calculated Channels Derived the second corresponds to inputs from Real Channels Using on blocks G, H, J and K. Each Advanced Mathematical connection block will accept up Functions to 2 differential inputs or up to 4 single-ended inputs (it is not The OM-SQ2040 Series combines a possible to mix single ended and higher channel count with the same differential inputs on a block). high performance, comprehensive features and universal inputs as the The OM-SQ2040-4F16 data logger OM-SQ2020 in a neat compact and has four analog to digital converters portable instrument. Using multiple (A/D’s) which increases logging 24-bit analog to digital convertors, twin flexibility over the other OM-SQ2020 processors and removable memory and OM-SQ2040 models. The first options provide great flexibility to corresponds to inputs on blocks A handle a wide range of complex and and B, the second corresponds to demanding multi-channel applications. inputs on blocks C and D, the third The OM-SQ2040 series are the ideal corresponds to inputs on blocks G data loggers for industrial, scientific and H and the fourth corresponds research and quality assurance to inputs on blocks J and K. Each applications. The OM-SQ2040 connection block will accept up to provides stand-alone data 2 differential inputs or up to 4 singleacquisition, advanced networked ended inputs (it is not possible to solutions and data analysis straight mix single-ended and differential out-of-the-box. inputs on a block). OM-SQ2040-2F16-WIFI data logger shown smaller than actual size. Concurrent Sampling The OM-SQ2040 series uses multiple analog to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure. Communications Ethernet, Wi-Fi (on the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. 1 This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels. Multiple Configurations Stored in the Logger The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data. Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC. Comprehensive Software Configuration The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. Data logger setup - channel configuration screen Input Channels Analog Input Channel Options OM-SQ2040-2F16 OM-SQ2040-4F16 Analog to Digital Converters 2 4 Differential Single ended 3 or 4 wire 16 32 0 16 32 8 Additional Channels Pulse Event/Digital High Voltage Internal Channels Logging Speeds (2x fast—64 kHz) and (2 x slow—100 Hz) 8 state inputs of 1 x 8 bit binary 2 2 temperature 1 sec to 1 day in sec increments 2, 5, 10, 20 or 100 Hz (20 or 100 HZ only on 2 channels) (2x fast—64 kHz) and (2 x slow—100 Hz) 8 state inputs of 1 x 8 bit binary 2 2 temperature 1 sec to 1 day in sec increments 2, 5, 10, 20 or 100 Hz (20 or 100 HZ only on 4 channels) Standard Ranges for Temperature Channels Each channel can be individually set to any of the ranges listed; Pt100 to IEC751 and JIS1604 and Pt1000 to IEC751 Input Type Range °C Range °F Y & U: Thermistor ** Pt100/P1000* -50 to 150 -200 to 850 -58 to 302 -328 to 15620 * 2-wire only on OM-SQ2040-2F16, 3- or 4-wire on OM-SQ2040-4F16 ** or user-defined thermistor (enter Steinhart-Hart coefficients or RT pairs) Thermocouple Type Range °C Range °F / -200 to 1372 -200 to 400 -200 to 1200 -200 to 1300 -50 to 1768 -328 to 2501 -328 to 752 -328 to 2192 -328 to 2372 -58 to 3214 2 16 to 32 universal analog inputs for recording temperature, current, voltage and resistance OM-SQ2040 data logger, rear view, shown smaller than actual size. USB, Ethernet and RS232 connectivity for quick and easy PC and remote communication and networking Power output for sensor excitation/ external devices Easy to use, removable connector system 2 high voltage channels (20, 40 or 60V) for automotive applications Power supply– internal alkaline batteries or external DC power supply Range of trigger functions via 8 digital inputs; 4 pulse rate/ counter inputs 4 alarm outputs for triggering external devices Standard Ranges for dc Voltage Each voltage channel can be any of the voltage ranges below. Mixed differential and single ended configurations are permitted. Voltage Range Voltage Range High Voltage Input Ranges* -0.075 to 0.075V -0.15 to 015V -0.3 to 0.3V -0.6 to 0.6V -0.6 to 1.6V -0.6 to 2.4V -3.0 to 3.0V -6.0 to 6.0V -6.0 to 12.0V -6.0 to 25.0V 4.0 to 20.0V 4.0 to 40.0V 4.0 to 60.0V * Max of 2 may be selected Standard Ranges for Current and Resistance Channels Each current channel can be any of the current ranges below. Current ranges use differential input channels. Current Range (External 10 Ω Shunt) -30.0 to 30.0 mA 4 to 20 mA Resistance Range 2 Wire 0.0 to 1250.0 Ω 0.0 to 5000.0 Ω 0.0 to 20000.0 Ω 0.0 to 300000.0 Ω Specifications Analog Inputs Accuracy: See table Common Mode Rejection: 100 dB Input Impedance: >1MΩ Linearity: 0.015% Series Mode Line Rejection: 50/60 Hz 100 dB Resistance Range Input Ranges 0.0 to 500.0 Ω 0.0 to 4000.0 Ω Analog Input Connections: Detachable screw terminal blocks Analog—Digital Conversion Type: Sigma-Delta Resolution: 24-bit Sampling Rate: Up to 10, 20* or 100* readings per second per ADC * With mains rejection off Alarm Outputs 4 x open drain FET (18 V 0.1 A) Digital I/O Connections: DB25F connector Calculated Channels Up to 16 virtual channels derived from physical input channels Resolution Up to 6 significant digits Programming/Logger Setup OM-SQ-SOFT or OM-SQ-SOFT-PLUS software Software compatible with XP/VISTA (32-bit & 64-bit)/7 (32-bit & 64-bit) Communication Standard: RS232 (automatic baud rate selection to 115200 baud) Ethernet 10/100 base TCP/IP USB 1.1 and 2.0 compatible Wireless Ethernet: (Wi-Fi); 802.11b, 2.4GHz, 1 to 14 channels Security: Open, WEP (64 or 128bi encryption), WPA or PA2/802.11i Network: Infrastructure only with specified SSID (external power pack required for Wi-Fi connection) 3 Input Channels Accuracy @ 23°C Differential voltage Single-ended voltage High voltage on block F Differential current 2-wire and 3-wire resistance (above 500 Ω) 4-wire resistance 2-wire and 3-wire temperature 4-wire temperature Differential J, K and N thermocouples (above -50°C) * Differential R, S and T thermocouples (above -50°C) * Single-ended J, K and N thermocouples (above -50°C) * Single-ended R, S and T thermocouples (above -50°C) * Pulse count and rate ±(0.025% of reading + 0.005% of full scale) ±(0.025% of reading + 0.005% of full scale) ±(0.075% of reading + 5 mV) ±(0.02% of reading + 0.015% of full scale) ±0.1% of reading ±(0.05% of reading + 0.15 Ω) ±(0.1% of reading + 0.1% of full scale) ±(0.05% of reading + 0.05% of full scale) ±0.075% of full scale ±0.175% of full scale ±0.1% of full scale ±0.225% of full scale ±(0.0011% of reading +1) * Includes cold junction compensation (CJC) error. Data logger held at constant temperature. External Options: GSM, WIFI and PSTN Modems Power Supply Internal: 6 “AA” alkaline batteries (included) External: 10 to 18 Vdc reverse polarity and over-voltage protected Power Consumption @ 9V Sleep Mode: 600 µA Logging: 40 to 130 mA Display and keypad 2 line x 20 character LCD display; battery state and external power indicator; keypad lock Navigate To: Arm/disarm/pause/ continue; meter any channel or alarm; select from up to 6 x pre-stored setups; status/diagnostics/memory/ time and date; download to MMC/SD Operating Environment Temperature: -30 to 65°C (-22 to 149°F) Humidity: 90% at 40°C non-condensing GENERAL Power Output for External Device: Regulated 5 Vdc at 50 mA or logger supply voltage at 100 mA Time and Date: Built-in clock in 3 formats Scaling Data: Displays readings in preferred engineering units Internal Memory: 16 MB (Up to 1,800,000 readings) External Memory: Up to 1 GB— removable MMC/SD (for transferring internal memory and storing setups only) Dimensions: 175 H x 235 W x 95 mm D (6.9 x 9.3 x 3.7") Weight: Approx. 1.2 kg (2.6 lb) Enclosure Material: ABS Memory Modes (Internal Only): Stop when full or overwrite OM-SQ2040-2F16-WIFI data logger shown smaller than actual size. SM Extended Warranty Program OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales respresentative for full details when placing an order. OMEGACARESM covers parts, labor and equivalent loaners. To Order Model No. OM-SQ2040-2F16 OM-SQ2040-4F16 OM-SQ2040-2F16-WIFI OM-SQ2040-4F16-WIFI Description Portable data logger with 2 fast channels Portable data logger with 4 fast channels Portable data logger with 2 fast channels and integrated Wi-Fi networking Portable data logger with 4 fast channels and integrated Wi-Fi networking Comes complete with software, USB cable, wall bracket, 6 “AA” batteries, 10 input terminal blocks, 4 current shunt resistors and operator’s manual. To order data logger with calibration certificate, add suffix “-CAL” to model number. Ordering Example: OM-SQ2040-2F16 portable data logger with 2 fast channels, OM-SQ-SOFT-PLUS software and OCW-1 OMEGACARE 1 year extended warranty for OM-SQ2040-2F16 adds 1 year to standard 1-year warranty. Accessories Model No. OM-SQ-NET-ADAP OM-SQ-GSM-KIT OM-SQ-RF-ADAP OM-SQ-UNIV-ADAP OM-SQ-UNIV-ADAP-1 OM-SQ-CS OM-SQ-SER-CABLE OM-SQ-USB-CABLE OM-SQ-TB3 OM-SQ-TB4 OM-SQ-TB6 OM-SQ-SOFT-PLUS OM-SQ-SOFT-PLUS-LIC Description Serial/ethernet converter kit GSM modem kit Wireless network adaptor Universal power pack Universal power pack with 1 m (3.2') flying lead Spare current shunts (package of 4) OM-SQ data logger to PC serial port cable Spare OM-SQ data logger to PC USB port cable Spare 3-way terminal block with cable restraint Spare 4-way terminal block with cable restraint Spare 6-way terminal block with cable restraint OM-SQ2040 plus software OM-SQ2040 plus software multi-user license 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : omega engineering Title : Portable Data Logger Create Date : 2016:01:15 14:05:39-05:00 Metadata Date : 2016:01:18 09:56:08-05:00 Modify Date : 2016:01:18 09:56:08-05:00 Creator Tool : Adobe InDesign CS5.5 (7.5.2) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 12107 bytes, use -b option to extract), (Binary data 12684 bytes, use -b option to extract) Instance ID : uuid:866a3891-e932-da4c-af3e-7fc9b8070f5c Original Document ID : xmp.did:9466DB9B4B20681180838EA792701FE8 Document ID : xmp.did:9466DB9B4B20681180838EA792701FE8 Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:9466DB9B4B20681180838EA792701FE8, xmp.iid:EC681C4F4C20681180838EA792701FE8, xmp.iid:ED681C4F4C20681180838EA792701FE8, xmp.iid:44A8A4964C20681180838EA792701FE8, xmp.iid:72ABA8864D20681180838EA792701FE8, xmp.iid:4C1760E14D20681180838EA792701FE8, xmp.iid:C004A04C4E20681180838EA792701FE8, xmp.iid:263689B04E20681180838EA792701FE8, xmp.iid:4F19AF094F20681180838EA792701FE8, xmp.iid:635E4C344F20681180838EA792701FE8, xmp.iid:9C8024384F20681180838EA792701FE8, xmp.iid:9D8024384F20681180838EA792701FE8, xmp.iid:877FF31A49206811822A9DB854B6E732, xmp.iid:4D1D3374072068118083A51A680F1FDB, xmp.iid:6FF4BB0A0A2068118083A51A680F1FDB, xmp.iid:B16BA9EA30206811BB8ED2FABBC22568, xmp.iid:1B5C53FB30206811BB8ED2FABBC22568, xmp.iid:5F16E52E10206811822AD16952406AEB, xmp.iid:5F6DCD4D10206811822AD16952406AEB, xmp.iid:652F1109182068118083B327922945CB, xmp.iid:E123AD5B192068118083B327922945CB, xmp.iid:719C8197482068118083E451E97FFFAA, xmp.iid:2AB6C7A5482068118083E451E97FFFAA, xmp.iid:532A2DE8482068118083E451E97FFFAA, xmp.iid:5C67EF72352068118083A0D68FAF2B5D, xmp.iid:C07375441A2068118A6DAAC5BEB78EFE, xmp.iid:70AD6DED1B2068118A6DAAC5BEB78EFE, xmp.iid:97E590172A2068118A6DAAC5BEB78EFE History When : 2012:05:15 16:27:56-04:00, 2012:05:15 16:28:41-04:00, 2012:05:15 16:28:41-04:00, 2012:05:15 16:30:41-04:00, 2012:05:15 16:37:24-04:00, 2012:05:15 16:39:56-04:00, 2012:05:15 16:42:56-04:00, 2012:05:15 16:45:43-04:00, 2012:05:15 16:48:13-04:00, 2012:05:15 16:49:25-04:00, 2012:05:15 16:49:31-04:00, 2012:05:15 16:50:14-04:00, 2012:05:17 16:57:59-04:00, 2012:05:18 08:56:26-04:00, 2012:05:18 09:14:57-04:00, 2012:05:18 15:56:22-04:00, 2012:05:18 15:56:50-04:00, 2012:05:18 16:40:43-04:00, 2012:05:18 16:41:35-04:00, 2013:01:02 12:54:19-05:00, 2013:01:02 13:03:47-05:00, 2014:03:05 17:40:13-05:00, 2014:03:05 17:40:37-05:00, 2014:03:05 17:42:29-05:00, 2015:12:04 15:25:50-05:00, 2015:12:31 12:24:25-05:00, 2015:12:31 12:36:18-05:00, 2015:12:31 14:17:42-05:00 History Software Agent : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Doc Change Count : 335 Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 4 Author : omega engineering Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools