Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers
make saving energy and saving money easy.
n

n

n

O
 ccupancy sensors turn lights on when you enter a room and save
energy by automatically turning them off when room is unoccupied.
V
 acancy sensors save more energy by requiring anyone entering the
room to manually turn on the lights. When the room is unoccupied,
the lights will turn off.

 sing occupancy and vacancy sensors may contribute to LEED
U
certification and help make buildings sustainable.

Pass & Seymour Sensors and Timers help meet
energy codes. They are convenient, easy-to-install,
and compatible with all standard types of lighting.
Sensors add to the comfort, safety and security
of the people who occupy the building.
Timers turn loads off when no longer needed.

Index
Device
Technology
Applications
Residential Vacancy Sensors
Residential Occupancy Sensors
Residential Occupancy/Vacancy Sensors
Commercial Occupancy Sensors
Wall Box
Wall or Ceiling Mount
Ceiling Mount
Ultrasonic Ceiling Mount
Dual Technology Ceiling Mount
Commercial Occupancy/Vacancy Wall Box Sensors
Power Packs & Add-A-Relay
Useful Calculations
Timers
Wall Box Timers

Page Number
M-2
M-3
M-4
M-5
M-6, M-7
M-8
M-11
M-12
M-13
M-14
M-9, M-10
M-15
M-16
M-17, M-18
M-19

M-1

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Technology

Passive Infrared Sensors (PIR)
Using a patented fresnel lens which minimizes optical aberrations, each Pass & Seymour/​
Legrand PIR sensor breaks its coverage area into zones. Upon detecting an infrared energy
change within a zone, one of the elements in the dual-element pyroelectric sensing device of an
occupancy sensor generates a positive pulse. Within milliseconds, the other element produces
a negative pulse and the lights are turned on. Vacancy sensors turn lights off when the room is
vacant for a period of time, or when there is no infrared energy detected within a zone.
Passive infrared sensors are unable to detect occupancy around barriers, and are more
effective when sensing movement across their field of sight rather than towards or away
from it.
All Pass & Seymour/Legrand PIR occupancy sensors feature:
n Patented fresnel lenses with multi-segment design
n Dual-element pyroelectric sensors
n Low-profile design
n Daylight filter systems
n Adjustable settings for time and sensitivity
n Custom Detection Signature Analysis for high immunity to RFI and EMI, and reliability
n Self-adaptive technology is available on some models

Ultrasonic Sensors
Ultrasonic sensors use a multi-directional transmitter/receiver system to broadcast ultrasonic
sound waves generated by a quartz crystal oscillator, and then measure the amount of time it
takes the waves to return. Movement within the area results in the sound waves returning to
the sensor at a slower or faster rate, and thus occupancy is detected.
Ultrasonic sensors broadcast in three dimensions, and are therefore able to detect smaller
movements than PIR sensors. Proper placement of the sensors is essential as sound waves
can escape through open doorways, resulting in false triggering.
While Pass & Seymour/Legrand ultrasonic sensors use special circuitry to filter out air-flow
movement caused by HVAC equipment or fans, sensors should be kept away from breezy
areas. Also, heavy carpeting and other sound-absorbing materials used in the construction of
a room will reduce coverage.
Pass & Seymour/Legrand ultrasonic occupancy sensor features:
n Temperature- and humidity-resistant tuned receivers
n Signal Processing Circuitry
n Solid-state, crystal-controlled transmitter
n Adjustable controls for time and sensitivity

Technology

Dual Technology
Dual Technology sensors combine PIR and Ultrasonic sensing in one device. This minimizes
false ONs and nuisance OFFs. Sensitivity adjustments and user selectable operational
characteristics make dual technology sensors the most versatile, even in the most difficult
installations.
Use dual technology sensors for the most demanding sensor applications. Odd shaped rooms,
lots of partitions, and changing floor plans can be handled best by dual technology sensors.

M-2

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Applications

P&S Model

Catalog
Page #

Best Suited For:

Residential Occupancy Sensors
RW500U
RWU600U

M-5
M-5

Storage rooms, walk-in closets, pantries, garage where no neutral is available
Storage rooms, walk-in closets, pantries, garage where a neutral is available

Residential Vacancy Sensors (T24 Compliant)
RW500B
RWU600B

M-4
M-4

Bedrooms, basements bathrooms, laundry rooms, where no neutral is available
Bedrooms, basements bathrooms, laundry rooms, where a neutral is available

3-Way Residential Occupancy/Vacancy Sensor (T24 Compliant)
RW3U600

M-6	Any room/hall with multiple entrances — allows manual ON/OFF control from both
locations. Can be switched between occupancy and vacancy.

Residential Occupancy/Vacancy Sensor with Dimmer
RWDU500

M-7

Any room where adjustable light level is desired

Commercial Passive Infrared (PIR) Wall Box Sensors
WSP200
OS300S
OSR300S

M-8
Small offices, closets, utility rooms with no partitions or obstructions
M-9
Small offices, closets, small conference rooms with no partitions or obstructions
M-10	Small rooms with two individually-controlled loads or bi-level lighting with
no partitions or obstructions

Commercial Passive Infrared (PIR) Ceiling Sensors
CS500
CS1200

M-12
M-12

Open offices, lunch, utility, storage, and computer rooms with no partitions or obstructions
Larger rooms, up to 1200 sq. ft., with open floor plans, no partitions or obstructions

Commercial Passive Infrared (PIR) Wall or Ceiling Mount Sensors
HS1001
WA1001

M-11
M-11

Hallways, or aisles
Entrances, vestibules, classrooms, for wide-angle applications

Commercial Ultrasonic Ceiling Mount Sensors
CSU600
CSU1100
CSU2200

M-13
M-13
M-13

Offices, computer, meeting, copy, and restrooms
Offices, lunch, break and classrooms, restrooms, and conference rooms
Offices, lunch, break and classrooms, restrooms, conference rooms, halls, storage areas

Commercial Dual Technology Sensors
CSD1000

M-14	Meeting, conference and classrooms, restrooms, dressing rooms, libraries,
interview rooms, testing areas, lunch and break rooms

Timers
RT1
RT12
RT24
97015, 30, 60
97115, 30, 60
97352

M-17
M-18
M-18
M-19
M-19
M-19

Closets, bathroom fans, exhaust fans, heat lamps, bedrooms
Garages, basements, laundry rooms, fans, motors, landscape lights
Exterior lights, landscape lighting, security lighting, holiday lighting
Bathroom fans, heat lamps, guest rooms
Bathroom fans, heat lamps, guest rooms where a hold function is desired
Dual control for bathroom light and fan

Applications

M-3

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Residential Vacancy Sensors
Passive Infrared (PIR)

Features

1.88"

1.69"

2.63"

RW500BLACC4

1.88"

cULus listed.
5-year warranty.
RW500B only
n	Incandescent.
RWU600B only
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp.

California Title 24 compliant.
Replaces a standard light or fan single pole switch.
n Lighted switch for visibility in darkened rooms.
n Manual-ON operation.
n	Fixed 30-minute time delay, no adjustment
necessary.
n	Low-profile styling with uniform color-matched
lens and device.
n Coverage: 180°, max. 600 ft.2 (56m2).
n

n

n

n

						
Catalog 			
Auto Manual
Number
Description
Voltage Load
ON
ON

Selectable
Auto/Man.
ON

Color

Single Pole Vacancy Sensors
RW500BICC4				
No neutral required,
RW500BWCC4
120VAC 25-500W
ideal for bedrooms
RW500BBKCC4
60 Hz
Incandescent
and baths
RW500BLACC4
			

No
No
No
No

Yes
Yes
Yes
Yes

No
No
No
No

Ivory
White
Black
Lt. Almond

RWU600BICC4				
Neutral required,
RWU600BWCC4
120VAC 0-600W
ideal for bedrooms
RWU600BBKCC4
60 Hz
All
and baths
RWU600BLACC4
			

No
No
No
No

Yes
Yes
Yes
Yes

No
No
No
No

Ivory
White
Black
Lt. Almond

1.69"

Coverage

Residential Vacancy Sensors

2.63"

RWU600BLACC4

M-4

RW500B Wiring

RWU600B Wiring

Wiring for RW500B does not require a neutral.

Wiring for RWU600B requires a neutral.

All devices listed on this page conform to NEMA WD-1 and WD-6.

Residential Occupancy Sensors
Passive Infrared (PIR)

Features
Replaces a standard light or fan single pole switch.
n Lighted switch for visibility in darkened rooms.
n Automatic-ON operation.
n	Fixed five-minute time delay.
n	Low-profile styling with uniform color-matched
lens and device.
n Coverage: 180°, max. 600 ft.2 (56m2)
n

cULus listed.
n 5-year warranty.
n	Works with most common residential
lighting types
RWU600U only
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
n

						
Selectable
Catalog 			
Auto Manual Auto/Man.
Number
Description
Voltage Load
ON
ON
ON

Color

1.88"

1.69"

2.63"

RW500ULACC4

Single Pole Occupancy Sensors
RW500UICC4				
No neutral required,
RW500UWCC4
120VAC 25-500W
ideal for storage
RW500UBKCC4
60 Hz
Incandescent
and utility rooms
RW500ULACC4
			

Yes
Yes
Yes
Yes

No
No
No
No

No
No
No
No

Ivory
White
Black
Lt. Almond

RWU600UICC4
RWU600UWCC4
RWU600UBKCC4
RWU600ULACC4

Yes
Yes
Yes
Yes

No
No
No
No

No
No
No
No

Ivory
White
Black
Lt. Almond

Neutral required,			
controls most types
120VAC 0-600W
of lighting, ideal for
60 Hz
All
storage & utility rooms			

1.88"

1.69"

2.63"

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Coverage

RWU600ULACC4

RWU600U Wiring

Wiring for RW500U does not require a neutral.

Wiring for RWU600U requires a neutral.

All devices listed on this page conform to NEMA WD-1 and WD-6.

M-5

Residential Occupancy Sensors

RW500U Wiring

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Residential Occupancy/Vacancy Sensors
3-Way Passive Infrared (PIR)

Applications
The RW3U600 has the flexibility to work in a variety of applications including hallways, stairways,
bathrooms, living and dining rooms, and other areas with multiple entries. The RW3U600 vacancy
sensor allows true multi-way operation with automatic ON/OFF control.

Features
California Title 24 compliant.
Occupancy-based control plus multi-way operation.
n	Two or more RW3U600s connected together will
allow enhanced coverage of the controlled space.
n Works with most common residential lighting types.
n	Adjustable time delay of 15 seconds to 30 minutes.
n	Light level sensing prevents automatic ON of lights
when adequate daylight exists.
n	Replaces three-way or four-way switches when used
with other RW3U600s.
n Lighted switch for visibility in darkened rooms.

RW3U600W
shown with
SWP26W

Manual- or automatic-ON operation.
	Adjustable light level setting of 10 to 150 fc
(100 to 1500 lux).
n Coverage: 180°, max. 600 ft.2 (56m2).
n cULus listed.
n 5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp

n

n

n

n

						
Selectable		
Catalog 			
Auto Manual Auto/Man.		
Number
Description
Voltage Load
ON
ON
ON
Color

Light
Level
Sensing

Single Pole/3-Way Occupancy/Vacancy Sensors*

1.5"

RW3U600I
RW3U600W
RW3U600BK
RW3U600LA

2.8"

Light-level sensing for			
optimum operation –
120VAC 0-600W
ideal for rooms with
60Hz
All
multiple entrances			

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Ivory
White
Black
Lt. Almond

Yes
Yes
Yes
Yes

Residential Occupancy/Vacancy Sensors

*In multi-way circuits, unit operates properly when used with other RW3U600 sensors only.
4.8"

Coverage

RW3U600W

RW3U600 Wiring for 3-Way Operation

Product Controls

RW3U600

M-6

All devices listed on this page conform to NEMA WD-1 and WD-6.

Residential Occupancy/Vacancy Sensors
Passive Infrared (PIR) with Dimmer

Features
California Title 24 compliant.
	Replaces standard single pole switch or
incandescent dimmer.
n	Low-profile styling with uniform color-matched
lens and device.
n Lighted pushbutton for visibility in darkened rooms.
n	Manual- or automatic-ON operation.
n	Adjustable time delay from 15 seconds
to 30 minutes.
n Soft start technology to prolong lamp life.

Air gap isolation switch for safe relamping.
	If enabled, light level sensing prevents
automatic-ON when adequate daylight exists.
n	Adjustable light level setting from 10-150 fc
(100-1500 lux) for daylight sensing.
n	Operating conditions: 32°-104°F (0°-40°C),
95% RH, noncondensing.
n Coverage: 180°, max. 600 ft2 (56 m2).
n cULus listed.
n 5-year warranty.

n

n

n

n

						
Selectable
Catalog 			
Auto Manual Auto/Man.
Number
Description
Voltage Load
ON
ON
ON

1.77"

1.73"

Color

2.67"

Occupancy/Vacancy Sensors with Preset Dimmers
RWDU500I
RWDU500W
RWDU500BK
RWDU500LA

Neutral required, ideal			
for living, dining and
120VAC 25-500
family rooms, master
60Hz
Incandescent
bathrooms and bedrooms		

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Ivory
White
Black
Lt. Almond

RWDU500W

Coverage

Black -> HOT (power
from circuit box)

Red -> LOAD (power
to dimmable lamp)

White ->
NEUTRAL

Product Controls

When more that one dimmer is installed
in a multi-gang box, it is necessary
to reduce the maximum load on each
dimmer.
•F
 or an RWDU500 in either end
position of a multi-gang box, reduce
the maximum load by 50W.
•F
 or an RWDU500 in a central position
of a multi-gang box, reduce its
maximum load by 100W. Mounting in
a deep electrical box is recommended.
RWDU500

Green -> GROUND

All devices listed on this page conform to NEMA WD-1 and WD-6.

M-7

Residential Occupancy/Vacancy Sensors

De-rating

RWDU500 Wiring

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors

Occupancy & Vacancy Sensors & Timers

Commercial Occupancy Sensors
Wall Box Passive Infrared (PIR)
1.765"

Features
	Detection Signature Analysis provides high
immunity to RFI and EMI.
n	Compact, decorator design replaces existing
wall switch.
n	Integrated light level sensor works from
10 to 150 footcandles.
n	Compatible with all electronic and magnetic
ballasts, PL lamp ballasts, compact fluorescent.
n	Adjustable time delay of 30 seconds to 30 minutes.
n Dual 120/277VAC operation.
n

2.610"

3.813"
4.125"

3.272"

1.310"

WSP200LA

Catalog
Number

Description

Voltage

30% to 60% energy savings.
Positive detection indicator.
n No minimum load requirement.
n Adjustable sensitivity from 20% to 100%.
n Patented voltage drop protection.
n Patented Zero Crossing Circuitry.
n 180° coverage of up to 900 sq. ft.
n cULus listed.
n 5-year warranty.
n
n

Load

Color

Automatic Wall Switches – 3 Wire Technology
WSP200I			
WSP200W
PIR
120/277VAC;
800W Max. at 120V
WSP200GRY
Occupancy Sensor
60 Hz
1200W Max. at 277V
WSP200LA				

Ivory
White
Gray
Light Almond

Planning a Layout
The WSP200’s 2-level lens provides superior coverage at desktop level by allowing the sensor
to detect vertical as well as horizontal motion. Coverage shown is for walking motion. Under
optimum conditions with a high level of activity and with no barriers or obstacles, coverage can
reach a maximum of 900 square feet. Under a typical, desktop level of activity, when mounted
at 4 feet, coverage is 300 square feet.

Factory settings:
30 min. time delay,
maximum light level
and sensitivity

WSP200

Single Level Lighting
WSP200

M-8

Manual Bi-level Lighting
WSP200
Technical Specifications on Page U-127.
All devices listed on this page conform to NEMA WD-1 and WD-6.

Commercial Occupancy/Vacancy Sensors
Wall Box Passive Infrared (PIR)

Features
	Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n Zero-crossing for long relay life.
n	Vandal-resistant lens combines precise
coverage with durability.
n Choice of Auto-ON or Manual-ON operation.
n	Auto adjustable time delays: automatic, fixed
(5, 10, 15, 20, 25 or 30 minutes), walk-through,
test-mode.
n	Selectable time delay automatically adjusts
for maximum savings.
n	Walk-through mode turns lifts off 3 minutes
after the area is initially occupied – ideal for
brief visits such as mail delivery.
n	Selectable test mode allows quick and
easy adjustments.
n Selectable audible alert for impending shutoff.
n

	In AUTO-ON mode, if the sensor is manually
turned OFF, AUTO-ON will not enable until no
motion is detected for 5 minutes. This prevents the
light from turning ON when it was intended they
remain OFF. Ideal for presentations.
n LED indicates occupancy detection.
n	Built-in light level sensing with simple,
one-step setup.
n	Override mode allows sensor to operate as a
service switch in the unlikely event of a failure.
n	NEMA WD 7 guideline utilized for coverage testing.
n	Sensitivity adjustment: PIR (high/low).
n	Coverage: 180°, up to 1050 sq. ft.;
major motion 35' x 30'; minor motion 20' x 15'.
n cULus listed.
n 5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
n

1.76"
1.83"

2.73"

OS300SW

				
Occupant Selectable
Catalog 			
Warning Auto/Man.
Number
Description
Rating
Load Before OFF
ON
Color

Single-Pole Occupancy/Vacancy Sensors
120/230/277VAC; 50/60 Hz.		
@ 120VAC, 0-800 W ballast
or tungsten, 1/6 hp. 		All
@ 230/277VAC, 0-1200 W ballast.		

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Ivory
White
Gray
Lt. Almond

Coverage

For best performance, Pass & Seymour/Legrand
recommends using this sensor in spaces no
larger than 15' x 20'.

Product Controls

DIP Switch Settings
ON/OFF Button

DIP Switches

Detection LED
PIR Lens

OS300S

Technical Specifications on Page U-127.
All devices listed on this page conform to NEMA WD-1 and WD-6.

M-9

Commercial Occupancy/Vacancy Sensors

OS300SI
Self-adaptive
OS300SW
design remembers
OS300SGRY
ON/OFF cycles
OS300SLA		

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Commercial Occupancy/Vacancy Sensors
Bi-Level Wall Box Passive Infrared (PIR)
Features
	Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n Zero-crossing for long relay life.
n	Vandal-resistant lens combines precise
coverage with durability.
n	Choice of Auto-ON or Manual-ON operation,
selectable for each relay.
n	Auto adjustable time delays: automatic,
fixed (5, 10, 15, 20, 25 or 30 minutes),
walk-through, test-mode.
n	Selectable time delay automatically adjusts
for maximum savings.
n	Selectable walk-through mode turns lights off
three minutes after the room is initially occupied
if no motion is detected after the first 30 seconds.
n	Selectable test mode allows quick and
easy adjustments.
n Selectable audible alert for impending shutoff.
n

1.76"
1.83"

2.73"

OSR300SW

				
Occupant Selectable
Catalog 			
Warning Auto/Man.
Number
Description
Rating
Load Before OFF
ON
Color

Single-Pole Dual-Relay Occupancy/Vacancy Sensors
OSR300SI
Operates both
OSR300SW
circuits of a bi-level
OSR300SGRY lighting system
OSR300SLA		

Commercial Occupancy/Vacancy Sensors

	In AUTO-ON mode, if the sensor is manually
turned OFF, AUTO-ON will not enable until no
motion is detected for 5 minutes. This prevents
the light from turning ON when it was intended
they remain OFF. Ideal for presentations.
n LED indicates occupancy detection.
n	Built-in light level sensing with simple,
one-step setup.
n	Override mode allows sensor to operate as a
service switch in the unlikely event of a failure.
n	NEMA WD 7 guideline utilized for coverage testing.
n Sensitivity adjustment: PIR (high/low).
n	Coverage: 180°, up to 1050 sq. ft.;
major motion 35' x 30'; minor motion 20' x 15'.
n cULus listed.
n 5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp.
n

Coverage

120/230/277VAC; 50/60 Hz.		
@ 120VAC, 0-800 W ballast
All
or tungsten, 1/6 hp.		
@ 230/277VAC, 0-1200 W ballast.		

OSR300S Bi-Level Wiring

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Ivory
White
Gray
Lt. Almond

OSR300S Two Circuit Level Wiring

For best performance, Pass & Seymour/Legrand recommends
using this sensor in spaces no larger than 15' x 20'.

Product Controls

DIP Switch Settings
ON/OFF Button

DIP Switches

Detection LED
PIR Lens

OSR300S

M-10

Technical Specifications on Page U-127.
All devices listed on this page conform to NEMA WD-1 and WD-6.

Commercial Occupancy Sensors
Wall or Ceiling Mount Passive Infrared (PIR)
Features – WA1001 and HS1001
	Detection Signature Analysis provides high immunity
to RFI and EMI.
n 2 coverage patterns to choose from.
n Wall mount or ceiling mount.
n Adjustable sensitivity settings.
n Digital time delay from 15 seconds to 30 minutes.
n	Dual-element, temperature-compensated
pyroelectric sensor.
n

2.034"

LED occupancy detection indicator.
n	Compatible with 120VAC or 277VAC, 60 Hz
lighting systems.
n Class 2 low-voltage device.
n	Positive detection indicator.
n cULus listed.
n 5-year warranty.
n

Catalog 			
Number
Description
Voltage

Current
Draw

Coverage

Color

3.335"

3.367"

WA1001
HS1001

Wall/Ceiling Mount Sensors
WA1001	Wide Angle PIR
Occupancy Sensor

24VDC

8mA

Up to 1200 sq. ft.

White

HS1001	Long Range PIR
Occupancy Sensor

24VDC

8mA

Up to 50 linear ft.

White

Reference Page M-15 for Power Packs.

WA1001

HS1001

Wiring Diagram

For best results, the bracket should
be used in every installation to allow
for greatest flexibility of adjustment.
Brackets are included with each unit.

Technical Specifications on Page U-128 and U-129.

All devices listed on this page
conform to NEMA WD-1
and WD-6.

M-11

Commercial Occupancy Sensors

Detection of motion
toward the sensor
begins at a max. of
50'. Reliable detection
occurs at 35' to 40'.

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Commercial Occupancy Sensors
Ceiling Mount Passive Infrared (PIR)
2.2"

Features
	ASIC technology reduces components and
enhances reliability.
n	Pulse count processing eliminates false offs
without reducing sensitivity.
n	Detection signature analysis eliminates false
triggers and proves immunity to RFI and EMI.
n	Low-profile design ensures a clean and
uncluttered ceiling appearance.
n	User-adjustable time delay from 15 seconds to
30 minutes by two minute increments.
n

3.3"

CS500
CS1200

	Sensitivity is programmed through a DIP switch
and has four settings from minimum to
maximum.
n	Dual-element, temperature compensated pyroelectric sensor.
n	Mounting options: ceiling tile or 3.0 inch round
mudring.
n	Units per power pack: up to 13.
n cULus listed.
n 5-year warranty.
n

				
Catalog				
Number
Description
Rating
Coverage

Override and
Output
Disable
Color

Low-Profile Ceiling Mount Sensors
CS500

PIR Occupancy Sensor

CS1200

PIR Occupancy Sensor

24VDC Input, requires
Power Pack 11mA

360°, 500 sq. ft.

No

White

360°, 1200 sq. ft.

No

White

Reference Page M-15 for Power Packs.
CS500/CS1200 Wiring

DIP Switch Settings

Commercial Occupancy Sensors

Mounting – CS1200

Coverage

Extended Range Lens
(Standard)
CS1200

M-12

High Density Lens
CS500

Technical Specifications on Page U-130.
All devices listed on this page conform to NEMA WD-1 and WD-6.

Commercial Occupancy Sensors
Ultrasonic Ceiling Mount
1.5"

Features
	Advanced signal processing circuitry helps to
eliminate false ONs.
n	Utilizes advanced, omni-directional (360°), Doppler
technology for reliable occupancy detection.
n	Angled transmitter and receiver pairs help
optimize sensitivity while eliminating unwanted
detection from ceiling air movement.
n	Digital DIP switch time delay (15 seconds to
30 minutes).
n

LED indicates occupancy detection.
Reliable solid-state construction.
n	Temperature and humidity resistant 32 kHz
receivers.
n	Mounts to ceiling tiles or box.
n	Units per power pack: up to 4.
n cULus listed.
n 5-year warranty.
n
n

4.8"

CSU600
				
Catalog				
Number
Description
Rating
Coverage

Override and
Output
Disable
Color

1.5"

Ultrasonic Ceiling Mount Sensors

4.8"

CSU600

Ultrasonic
Occupancy Sensor

24VDC Input, requires
Power Pack 27mA

360°, 500 sq. ft.
One-sided

Yes

White

CSU1100

Ultrasonic
Occupancy Sensor

24VDC Input, requires
Power Pack 30mA

360°, 1100 sq. ft.
Two-sided

Yes

White

CSU2200

Ultrasonic
Occupancy Sensor

24VDC Input, requires
Power Pack 30mA

360°, 2200 sq. ft.
Two-sided

Yes

White

Reference Page M-15 for Power Packs.
CSU600/CSU1100/CSU2200 Wiring

CSU1100
CSU2200

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Coverage

White (Neutral)
Red (Line)

Black

Red (Load)

Optional
Switch

Lighting
Load

Blue

Hot

POWER PACK

Black

White

Red

N

Common ( B L K)
+24VDC ( R E D )

Mounting

DIP Switch Settings

Attached to a vibration-free surface. Mount the
sensors with the receivers facing the area of coverage.
Note: Place 4' away from supply ducts, 6' from
horizontal discharge ducts, and 6" from power packs.

Technical Specifications on Page U-131.
All devices listed on this page conform to NEMA WD-1 and WD-6.

M-13

Commercial Occupancy Sensors

Control Output 24VDC ( B L U )

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Commercial Occupancy Sensors
Dual Technology Ceiling Mount
1.02"

Features
	Advanced control logic based on RISC
microcontroller provides:
- Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n	Walk-through mode turns lights off three minutes
after the area is initially occupied – ideal for brief
visits such as mail delivery.
n	Available with built-in light level sensor featuring
simple, one-step setup.
n	Ultrasonic diffusion technology spreads coverage
to a wider area (patented).
n	LEDs indicate occupancy detection.
n	Four occupancy logic options give users the ability
to customize control to meet application needs.
n

4.5"

CSD1000

Ultrasonic frequency of 40 kHz.
	Time delays: automatic, fixed (5, 10, 15, 20, or
30 minutes), walk-through, test-mode.
n	Sensitivity adjustment: reduce sensitivity (for
PIR sensitivity); ultrasonic sensitivity is variable
with trimpot
n	Multi-level, 360° Fresnel lens for superior
occupancy detection.
n	Mounting options: ceiling tile; 4 square junction
box with double gang mudring.
n Units per power pack: up to 4.
n cULus listed.
n 5-year warranty.
n
n

				
Catalog				
Number
Description
Rating
Coverage

Override and
Output
Disable
Color

Low-Profile Ceiling Mount Sensors
Dual Technology
Occupancy Sensor

CSD1000

24VDC Input, requires
Power Pack 35mA

360°, 1000 sq. ft.
Yes
Two-sided		

White

Reference Page M-15 for Power Packs.
CSD1000 Wiring

DIP Switch Settings
White (Neutral)

Red (Line)

Black

Red (Load)

Optional
Switch

Lighting
Load

Blue

Hot

POWER PACK

Black

White

Red

N

Control Output 24VDC ( B LU)
Common ( B LK )

Commercial Occupancy Sensors

+24VDC ( RE D)

Coverage

Mounting
Nut
7/8" (22mm)
hole

Washer
Threaded
Insert
Ceiling
Tile

Space:
Screws:
3mm/(1/8")
103mm (4.1") apart
Ceiling

Rotate
clockwise

M-14

Technical Specifications on Page U-132.
All devices listed on this page conform to NEMA WD-1 and WD-6.

Power Packs & Add-A-Relay

A cost-effective way to power Pass & Seymour/Legrand ®
occupancy sensors.
Pass & Seymour/Legrand power packs consist of a transformer and high-current relay in one small unit.
In addition to a primary high input, power packs have a secondary output of 24VDC, 100mA which
provides operating power to sensors. Upon sensing motion or insufficient light, sensors electrically close
an internal circuit and send 24VDC back to the power packs or Add-A-Relays that control lighting systems.
Unlike power packs, Add-A-Relay does not have transformer power supply, only an isolated relay.
Power packs can switch a maximum 20 Amps of fluorescent lighting. Both power packs and Add-A-Relay
are available for 120 and 277 Volt systems.

2.805"
2.916"

.842"

Features
	Secondary voltage: 24VDC;
Secondary output: 150mA.
n UL-rated 94 V0 plastic enclosure.
n cULus listed.
n 5-year warranty.

Essential to ceiling mount sensor systems.
Self-contained transformer and relay.
n Easy-to-install.
n	Teflon-coated wire leads suitable for plenum
applications.

n

n
n

Catalog 		
Number
Description

Input
Voltage

1.673"

1.634"

PWP2120
PWP2277
AR120/277

Load Ratings (Amps)
Ballast

Incan.

Motor

Output

20
20
20

13
—
13

1HP
1HP
1HP

24VDC; 150mA
24VDC; 150mA
*0

Power Packs & Add-A-Relay
PWP2120
PWP2277
AR120/277

Power Pack
Power Pack
Add-A-Relay

120
277
120/277

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

*Add-A-Relay has a current consumption of 36mA.

Installation
Power packs should be installed in accordance with state, local, and national electrical codes. They are
designed to attach to electrical enclosures with 1/2 inch knockouts. In plenum ceilings, power packs should
be installed in approved electrical enclosures. Most applications require UL listed, 18-22 AWG, 3-conductor,
class 2 cable for low-voltage wiring. For plenum rated ceilings use UL listed plenum-approved cables.
J-Box Installation

Power Pack Schematics

For additional Wiring
Diagrams, see
Pages U-22 & U-23.

Sensor Schematic with Add-A-Relay
Load

Neutral

Load
Red

White

Red

Blue

Black

Black

Red

Hot

Power
Pack

24VDC
Sensor

Switch

All devices listed on this page conform to NEMA WD-1 and WD-6.

Technical Specifications
on Page U-133.

M-15

Power Packs & Add-A-Relay

Ceiling Sensor with Power Pack

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Useful Calculations
Examples of savings and payback
EXAMPLE 1
Large office using a WA1001 Passive Infrared Sensor

Six 88-watt, 3-lamp fixtures = 0.528 kW x $0.086/kWh* = $0.04541/hr
Savings = 35 hours per week
Total hours saved = 1,820 hrs/yr
Annual Savings = $82.65; 5 Year Savings = $413.23
Total estimated cost including power pack: (Product and Labor) = $140.00
Payback = 20.33 months
ROI = $82.65 ÷ $140.00 = 59.03%
EXAMPLE 2
Individual office using a CS500 Automatic Wall Switch

Three 88-watt, 3-lamp fixtures = 0.264 kW x $0.086/kWh* = $0.02270/hr
Savings = 50 hours per week
Total hours saved = 2,600 hrs/yr
Annual Savings = $59.02; 5 Year Savings = $295.10
Total estimated cost: (Product and Labor) = $54.00
Payback = 10.98 months
ROI = $59.02 ÷ $54.00 = 109.30%
EXAMPLE 3
Restroom using a CSU1100 Ultrasonic Occupancy Sensor

Four 88-watt, 3-lamp fixtures = 0.352 kW x $0.086/kWh* = $0.03027/hr
Savings = 75 hours per week
Total hours saved = 3,900 hrs/yr
Annual Savings = $118.05; 5 Year Savings = $590.27
Total estimated cost: (Product and Labor) = $160.00
Payback = 16.26 months
ROI = $118.05 ÷ $160.00 = 73.78%
*Based on 2004 US Government National average cost.

Useful Calculations

Multi-Sensor Installation
For applications requiring more than one sensor, the load per power pack should not
exceed 150mA. Use the following table to calculate the maximum number of sensors per
power pack.
WA1001

CS500/1200

HS1001

CSU600

CSU1100/2200

AR120/277

CSD1000

8mA

11mA

8mA

27mA

30mA

36mA

35mA

Examples:
2 x CSU1100 (30mA) = 60mA 4
This is an acceptable load because it is less than 150mA.
4 x CSU1100 (30mA) + 1 x AR120/277(36mA) = 156mA 7
This is not an acceptable load because it is greater than 150mA.

M-16

Timers

Features
Seven-button preset time switch.
Manual ON/OFF.
n	Adjustable time delay: 1, 5, 10, 20, 30, 60 minutes.
n	Lighted switch for visibility in darkened rooms.
n Controls most types of lighting.

cULus listed.
5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp

n

n

n

n

				
Catalog 			
Number
Description
Rating
Load

TimeRunning-Out
Warning

Color

Digital Timers
RT1I				
RT1W
7-Button Digital Timer, 0-600W, 1/6 hp @ 120VAC 60 Hz
All
RT1BK
Neutral required			
RT1LA				

RT1 Wiring

No
No
No
No

Ivory
White
Black
Light Almond

RT1
shown with
SWP26

1.88"

1.69"

Product Controls
2.63"
Six time selection
buttons with activation
indicator lights

ON/OFF Button

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

RT1

RT1

M-17

Timers

All devices listed on this page conform to NEMA WD-1 and WD-6.

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Timers
Features

	Lighted switch for visibility in darkened rooms.
Works with most common lighting types.
n cULus listed.
n 5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp

Programmable countdown time switch
Manual ON/OFF.
n Digital countdown display.
n	Adjustable time delay from 5-55 minutes
(five-minute increments) to 1-12 hours
(15-minute increments).
n	Audible beep and visible light flash warnings
before automatic-OFF.

RT12
shown with
SWP26

n

n

n

n

				
Catalog 			
Number
Description
Rating
Load

TimeRunning-Out
Warning

Color

Digital Timers

1.88"

RT12I				
RT12W
12-Hour Digital Timer, 0-600W, 1/6 hp @ 120VAC 60 Hz
All
RT12BK Neutral required			
RT12LA				

1.69"

RT12 Wiring

Yes
Yes
Yes
Yes

Ivory
White
Black
Light Almond

Product Controls

2.63"
LCD Display
Lock Bar
Programming Buttons
Slide Down:
ON/OFF Button

RT12

RT12

Features
Manual or programmed ON/OFF switching.
Real time clock with day/date calendar.
n Easy to read LED display.
n	Programming buttons accessible without removing
wall plate.
n	Eight programs can be assigned to any day or
combination of days of the week.
n	Automatically calculates sunrise and sunset times
based on latitude and longitude.
n
n

RT24
shown with
wall plate

	Audible or visual occupant warning
before OFF.
n Power failure memory.
n Zero crossing circuitry.
n cULus listed.
n 5-year warranty.
n	Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
n

				
Catalog 			
Number
Description
Rating
Load

TimeRunning-Out
Warning

Color

Timers

Astronomic Programmable Timers
RT24I		
		
0-800W @ 120V
RT24W
24-Hour
All
0-1200W @ 277V
RT24BK Programmable Timer
1/6 hp @ 120/277V		
RT24LA				
Available Spring 2009.

M-18

Yes
Yes
Yes
Yes

Ivory
White
Black
Light Almond

All devices listed on this page conform to NEMA WD-1 and WD-6.

Wall Box Timers

125, 125-T, 250 & 277VAC, 60 Hz

Applications
Lighting
n Exhaust fans
n

n
n

Whirlpools and spas
Saunas

n
n

Heating and heat lamps
Ventilating and air conditioning

Features
	Units with “Hold” feature may be turned counter-clockwise to
hold the load on without timing function.
n	Turning clockwise causes unit to time load off after desired
time delay.
n Quiet operation.
n Time range from 5 minutes to 12 hours.
n Available with or without hold.
n

Catalog Number

Description

Decorator styling.
n Easily installed.
n Large head screw terminals.
n Accurate to ± 5 percent.
n Motor rated.
n Energy saving.
n

Time Range

97030I
		
97030W
Timeout, No Hold
30 Minutes
97030LA			
97060I
97060W

Timeout, No Hold
60 Minutes
		

97115I
97115W

Timeout, With Hold
15 Minutes
		

97130I
97130W

Timeout, With Hold
30 Minutes
		

97160I
97160W

Timeout, With Hold
60 Minutes
		

2.76"

4.20"

2.62"

3.281"

1.85"

1.80"

97015I
Color

Specification Grade Decorator Rotary Timers
97015I
		
97015W
Timeout, No Hold
15 Minutes
97015LA			

1.30"

1.80"

Ivory
White
Light Almond

Catalog
Number

Replacement Knobs
(without plate)

Ivory
White
Light Almond

PS55A1
PS55B1
PS55G1

Ivory
White

VAC

Ivory
White

Ivory
White
Ivory
White

Color

White
Ivory
Light Almond
Hz

Amp

HP

Occupancy & Vacancy Sensors & Timers

Occupancy & Vacancy Sensors & Timers

Ratings
125
125T
250
277

60
20
60		
60
10
60
10

1
7
1

Features
Eliminates the need for two switches.
Fits standard toggle opening for easy ganging.
n Time range adjustable from 1-60 minutes.
n Easily installed.
n May control one or two loads simultaneously.

Motor rated.
Silent operation.
n Reliable solid-state construction.
n Energy saving.

n

n

n

n

Catalog
Number

Description

Time Range

Rating

1.70"

Color

Specification Grade Toggle Time Delay Switches
Center Off
97352I
97352W

Double Pole,
1-60 Minutes, Adjustable 500W, 1/3 HP, 120VAC, 60 Hz
Double Throw			

	When toggle is up, one or two loads
remain on.
n	When toggle is down, load “A” is off, load
“B” times-off at preset time. In the center
position, both loads are off.
n

4.15"
3.281"

Ivory
White

Wiring Diagram: Single Timed Load Application

1.50"
1.80"

97352I

All devices listed on this
page conform to NEMA
WD-1 and WD-6.

M-19

Wall Box Timers

Operation: Catalog Number 97352

2.70"



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Warning                         : Invalid secondary xref table
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56
Instance ID                     : uuid:dce887fb-e290-4491-ad14-64e4261fa6e0
Document ID                     : adobe:docid:indd:fb31ee38-5635-11dd-819d-9547ca5c7e55
Rendition Class                 : proof:pdf
Derived From Instance ID        : 9630052c-5586-11dd-8f4a-8ea272d0eb60
Derived From Document ID        : adobe:docid:indd:78aabcb0-1758-11dd-a4b2-cc1f050f5bf6
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:B84B16A6450711DD8C7CC7B7AF3F59B0, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:71B7D3FC438311DDB94FF34B2D7B5993, uuid:4A3C068A438311DDB94FF34B2D7B5993, uuid:7955041E438311DDB94FF34B2D7B5993, uuid:79550425438311DDB94FF34B2D7B5993, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:024C29424E6811DDB46CF24FE72B7C74, uuid:024C29404E6811DDB46CF24FE72B7C74, uuid:43C4FB17177911DDB39788115DA64C78, uuid:2CDEFD60177911DDB39788115DA64C78, uuid:6FF524764EA311DD9E4C9061B0F7E607, uuid:6FF524784EA311DD9E4C9061B0F7E607, uuid:024C29464E6811DDB46CF24FE72B7C74, uuid:347343414E6B11DDB46CF24FE72B7C74, uuid:55FE6AE54E9611DD9E4C9061B0F7E607, uuid:43C4FB17177911DDB39788115DA64C78, uuid:2CDEFD60177911DDB39788115DA64C78, uuid:55FE6AE34E9611DD9E4C9061B0F7E607, uuid:024C29464E6811DDB46CF24FE72B7C74, uuid:347343414E6B11DDB46CF24FE72B7C74, uuid:DD0FA2835B3B11DD9C6287C04F9FB7EE, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:07800F00181B11DDA0BF87D1B0AA09A0, uuid:60A350B84DEB11DD9794E03679B979B7, uuid:2749C949692011DDADE782656D226970, uuid:43C4FB17177911DDB39788115DA64C78, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:2749C948692011DDADE782656D226970, uuid:024C29464E6811DDB46CF24FE72B7C74, uuid:347343414E6B11DDB46CF24FE72B7C74, uuid:D0C40E844E9711DD9E4C9061B0F7E607, uuid:2749C94A692011DDADE782656D226970, uuid:2749C94C692011DDADE782656D226970, uuid:2749C94D692011DDADE782656D226970, uuid:17cef1ac-1608-11da-ba6a-daefd94ad797, uuid:20C5BD0A4E5511DDA5B3DE12E3E61098, uuid:4C98F652692211DDADE782656D226970, uuid:2749C94E692011DDADE782656D226970, uuid:4C98F650692211DDADE782656D226970, uuid:4C98F651692211DDADE782656D226970, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:4C98F654692211DDADE782656D226970, uuid:0DFC67124E7E11DDB46CF24FE72B7C74, uuid:4C98F655692211DDADE782656D226970, uuid:4C98F656692211DDADE782656D226970, uuid:539787554E7611DDB46CF24FE72B7C74, uuid:257B98F44E5811DDA5B3DE12E3E61098, uuid:4C98F653692211DDADE782656D226970, uuid:6C1B993E4DE911DD9794E03679B979B7, uuid:AAAD67254E5A11DDA5B3DE12E3E61098, uuid:0DFC67194E7E11DDB46CF24FE72B7C74, uuid:E8B42F40556A11DDB97891E5208F02AF, uuid:1BA7138A693111DDADE782656D226970, uuid:74A4D4044E8011DDB46CF24FE72B7C74, uuid:022EEBA64E8311DDB46CF24FE72B7C74, uuid:74A4D4004E8011DDB46CF24FE72B7C74, uuid:74A4D4084E8011DDB46CF24FE72B7C74, uuid:87A41BF4182F11DDA5ADEC8F030868B6, uuid:1BA7138D693111DDADE782656D226970, uuid:D28BB236184A11DDB64F9D15D405215A, uuid:1BA7138E693111DDADE782656D226970, uuid:1BA7138C693111DDADE782656D226970, uuid:AB3A9EB1556511DD9254A47ABA566B66, uuid:1BA7138B693111DDADE782656D226970, uuid:A0A58582184211DDA5ADEC8F030868B6, uuid:1BA71391693111DDADE782656D226970, uuid:022EEBAD4E8311DDB46CF24FE72B7C74, uuid:1BA7138F693111DDADE782656D226970, uuid:1BA71390693111DDADE782656D226970, uuid:1BA71392693111DDADE782656D226970, uuid:C4E58E76693A11DDADE782656D226970, uuid:fd19d1d6-cc02-11d8-84d1-d58c5f5a3fd8, uuid:DFB30E71185D11DDA5ADEC8F030868B6, uuid:F63D15DA185D11DDA5ADEC8F030868B6, uuid:6FF524704EA311DD9E4C9061B0F7E607, uuid:1913208D4EA911DD9E4C9061B0F7E607, uuid:578BD94F4E9D11DD9E4C9061B0F7E607, uuid:976895A8185C11DDA5ADEC8F030868B6, uuid:758F2BF7185C11DDA5ADEC8F030868B6, uuid:6FF5246E4EA311DD9E4C9061B0F7E607, uuid:FAE379E9692211DD8789938EC78857CB, uuid:ce93f41d-d519-11d9-8a93-aa6ff8c95e3e, uuid:fbec040e-2e95-11da-a5ce-9696038135de
Manifest Reference Document ID  : uuid:B84B16A5450711DD8C7CC7B7AF3F59B0, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:0330984C438211DDB94FF34B2D7B5993, uuid:B0287F848ECC11DCACA68C47F4B577EB, uuid:D3AF29C78ECC11DCACA68C47F4B577EB, uuid:BF8D4A2797D811DB8AF7B13D68D61EAC, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:024C29414E6811DDB46CF24FE72B7C74, uuid:024C293F4E6811DDB46CF24FE72B7C74, uuid:43C4FB16177911DDB39788115DA64C78, uuid:2CDEFD5F177911DDB39788115DA64C78, uuid:6FF524754EA311DD9E4C9061B0F7E607, uuid:6FF524774EA311DD9E4C9061B0F7E607, uuid:024C29454E6811DDB46CF24FE72B7C74, uuid:347343404E6B11DDB46CF24FE72B7C74, uuid:55FE6AE44E9611DD9E4C9061B0F7E607, uuid:43C4FB16177911DDB39788115DA64C78, uuid:2CDEFD5F177911DDB39788115DA64C78, uuid:55FE6AE24E9611DD9E4C9061B0F7E607, uuid:024C29454E6811DDB46CF24FE72B7C74, uuid:347343404E6B11DDB46CF24FE72B7C74, uuid:DD0FA2825B3B11DD9C6287C04F9FB7EE, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:07800EFF181B11DDA0BF87D1B0AA09A0, uuid:60A350B74DEB11DD9794E03679B979B7, uuid:D0C40E7F4E9711DD9E4C9061B0F7E607, uuid:43C4FB16177911DDB39788115DA64C78, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:D0C40E814E9711DD9E4C9061B0F7E607, uuid:024C29454E6811DDB46CF24FE72B7C74, uuid:347343404E6B11DDB46CF24FE72B7C74, uuid:D0C40E834E9711DD9E4C9061B0F7E607, uuid:2861be5d-0996-11da-a34b-000d93b87d58, uuid:0a10da74-09ab-11da-a34b-000d93b87d58, adobe:docid:photoshop:17cef1ab-1608-11da-ba6a-daefd94ad797, uuid:20C5BD094E5511DDA5B3DE12E3E61098, uuid:5397874F4E7611DDB46CF24FE72B7C74, uuid:6FDE423A4E6F11DDB46CF24FE72B7C74, uuid:6FDE423C4E6F11DDB46CF24FE72B7C74, uuid:D0C40E874E9711DD9E4C9061B0F7E607, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:539787564E7611DDB46CF24FE72B7C74, uuid:0DFC67114E7E11DDB46CF24FE72B7C74, uuid:0DFC67134E7E11DDB46CF24FE72B7C74, uuid:539787584E7611DDB46CF24FE72B7C74, uuid:539787544E7611DDB46CF24FE72B7C74, uuid:D39F3EA54E5511DDA5B3DE12E3E61098, uuid:0DFC67154E7E11DDB46CF24FE72B7C74, adobe:docid:photoshop:898d1ec9-14b3-11da-a496-f3fdb0eb55a1, uuid:861708E84E5911DDA5B3DE12E3E61098, uuid:0DFC67184E7E11DDB46CF24FE72B7C74, uuid:74A4D4054E8011DDB46CF24FE72B7C74, uuid:6FF524734EA311DD9E4C9061B0F7E607, uuid:74A4D4034E8011DDB46CF24FE72B7C74, uuid:74A4D4014E8011DDB46CF24FE72B7C74, uuid:0DFC671A4E7E11DDB46CF24FE72B7C74, uuid:74A4D4074E8011DDB46CF24FE72B7C74, uuid:87A41BF3182F11DDA5ADEC8F030868B6, uuid:578BD9464E9D11DD9E4C9061B0F7E607, uuid:D28BB235184A11DDB64F9D15D405215A, uuid:C3A4FA2C184C11DDB64F9D15D405215A, uuid:D28BB239184A11DDB64F9D15D405215A, uuid:AB3A9EB0556511DD9254A47ABA566B66, uuid:E8B42F43556A11DDB97891E5208F02AF, uuid:91659A44184211DDA5ADEC8F030868B6, uuid:578BD94C4E9D11DD9E4C9061B0F7E607, uuid:022EEBAB4E8311DDB46CF24FE72B7C74, uuid:995B71766BF011DBAF34D10E686480AA, uuid:995B71786BF011DBAF34D10E686480AA, uuid:27297D706C0C11DB88AEBACB2B90E081, uuid:58A67166557711DDB97891E5208F02AF, adobe:docid:photoshop:e31f90c3-cc02-11d8-84d1-d58c5f5a3fd8, uuid:DFB30E70185D11DDA5ADEC8F030868B6, uuid:DFB30E78185D11DDA5ADEC8F030868B6, uuid:6FF5246F4EA311DD9E4C9061B0F7E607, uuid:1913208C4EA911DD9E4C9061B0F7E607, uuid:578BD94E4E9D11DD9E4C9061B0F7E607, uuid:758F2BFE185C11DDA5ADEC8F030868B6, uuid:758F2BF6185C11DDA5ADEC8F030868B6, uuid:578BD9504E9D11DD9E4C9061B0F7E607, uuid:FAE379E8692211DD8789938EC78857CB, adobe:docid:photoshop:ce93f41c-d519-11d9-8a93-aa6ff8c95e3e, adobe:docid:photoshop:fbec040d-2e95-11da-a5ce-9696038135de
Create Date                     : 2008:08:12 13:52:40-04:00
Modify Date                     : 2008:08:12 13:53:57-04:00
Metadata Date                   : 2008:08:12 13:53:57-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0.3)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9645 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 19
Creator                         : Adobe InDesign CS3 (5.0.3)
EXIF Metadata provided by EXIF.tools

Navigation menu