PASS And SEYMOUR Occupancy
User Manual: PASS and SEYMOUR occupancy
Open the PDF directly: View PDF .
Page Count: 19
Occupancy & Vacancy Sensors & Timers
Index
Device Page Number
Technology M-2
Applications M-3
Residential Vacancy Sensors M-4
Residential Occupancy Sensors M-5
Residential Occupancy/Vacancy Sensors M-6, M-7
Commercial Occupancy Sensors
Wall Box M-8
Wall or Ceiling Mount M-11
Ceiling Mount M-12
Ultrasonic Ceiling Mount M-13
Dual Technology Ceiling Mount M-14
Commercial Occupancy/Vacancy Wall Box Sensors M-9, M-10
Power Packs & Add-A-Relay M-15
Useful Calculations M-16
Timers M-17, M-18
Wall Box Timers M-19
M-1
Occupancy & Vacancy Sensors & Timers
Occupancy & Vacancy Sensors & Timers
make saving energy and saving money easy.
n
Occupancy sensors turn lights on when you enter a room and save
energy by automatically turning them off when room is unoccupied.
n
Vacancy sensors save more energy by requiring anyone entering the
room to manually turn on the lights. When the room is unoccupied,
the lights will turn off.
n
Using occupancy and vacancy sensors may contribute to LEED
certification and help make buildings sustainable.
Pass & Seymour Sensors and Timers help meet
energy codes. They are convenient, easy-to-install,
and compatible with all standard types of lighting.
Sensors add to the comfort, safety and security
of the people who occupy the building.
Timers turn loads off when no longer needed.
http://waterheatertimer.org/How-to-wire-switches.html#motion
Technology
M-2
Occupancy & Vacancy Sensors & Timers
Occupancy & Vacancy Sensors & Timers
Technology
Passive Infrared Sensors (PIR)
Using a patented fresnel lens which minimizes optical aberrations, each Pass & Seymour/
Legrand PIR sensor breaks its coverage area into zones. Upon detecting an infrared energy
change within a zone, one of the elements in the dual-element pyroelectric sensing device of an
occupancy sensor generates a positive pulse. Within milliseconds, the other element produces
a negative pulse and the lights are turned on. Vacancy sensors turn lights off when the room is
vacant for a period of time, or when there is no infrared energy detected within a zone.
Passive infrared sensors are unable to detect occupancy around barriers, and are more
effective when sensing movement across their field of sight rather than towards or away
from it.
All Pass & Seymour/Legrand PIR occupancy sensors feature:
n Patented fresnel lenses with multi-segment design
n Dual-element pyroelectric sensors
n Low-profile design
n Daylight filter systems
n Adjustable settings for time and sensitivity
n Custom Detection Signature Analysis for high immunity to RFI and EMI, and reliability
n Self-adaptive technology is available on some models
Ultrasonic Sensors
Ultrasonic sensors use a multi-directional transmitter/receiver system to broadcast ultrasonic
sound waves generated by a quartz crystal oscillator, and then measure the amount of time it
takes the waves to return. Movement within the area results in the sound waves returning to
the sensor at a slower or faster rate, and thus occupancy is detected.
Ultrasonic sensors broadcast in three dimensions, and are therefore able to detect smaller
movements than PIR sensors. Proper placement of the sensors is essential as sound waves
can escape through open doorways, resulting in false triggering.
While Pass & Seymour/Legrand ultrasonic sensors use special circuitry to filter out air-flow
movement caused by HVAC equipment or fans, sensors should be kept away from breezy
areas. Also, heavy carpeting and other sound-absorbing materials used in the construction of
a room will reduce coverage.
Pass & Seymour/Legrand ultrasonic occupancy sensor features:
n Temperature- and humidity-resistant tuned receivers
n Signal Processing Circuitry
n Solid-state, crystal-controlled transmitter
n Adjustable controls for time and sensitivity
Dual Technology
Dual Technology sensors combine PIR and Ultrasonic sensing in one device. This minimizes
false ONs and nuisance OFFs. Sensitivity adjustments and user selectable operational
characteristics make dual technology sensors the most versatile, even in the most difficult
installations.
Use dual technology sensors for the most demanding sensor applications. Odd shaped rooms,
lots of partitions, and changing floor plans can be handled best by dual technology sensors.
Catalog
P&S Model Page # Best Suited For:
Residential Occupancy Sensors
RW500U M-5 Storage rooms, walk-in closets, pantries, garage where no neutral is available
RWU600U M-5 Storage rooms, walk-in closets, pantries, garage where a neutral is available
Residential Vacancy Sensors (T24 Compliant)
RW500B M-4 Bedrooms, basements bathrooms, laundry rooms, where no neutral is available
RWU600B M-4 Bedrooms, basements bathrooms, laundry rooms, where a neutral is available
3-Way Residential Occupancy/Vacancy Sensor (T24 Compliant)
RW3U600 M-6 Any room/hall with multiple entrances — allows manual ON/OFF control from both
locations. Can be switched between occupancy and vacancy.
Residential Occupancy/Vacancy Sensor with Dimmer
RWDU500 M-7 Any room where adjustable light level is desired
Commercial Passive Infrared (PIR) Wall Box Sensors
WSP200 M-8 Small offices, closets, utility rooms with no partitions or obstructions
OS300S M-9 Small offices, closets, small conference rooms with no partitions or obstructions
OSR300S M-10 Small rooms with two individually-controlled loads or bi-level lighting with
no partitions or obstructions
Commercial Passive Infrared (PIR) Ceiling Sensors
CS500 M-12 Open offices, lunch, utility, storage, and computer rooms with no partitions or obstructions
CS1200 M-12 Larger rooms, up to 1200 sq. ft., with open floor plans, no partitions or obstructions
Commercial Passive Infrared (PIR) Wall or Ceiling Mount Sensors
HS1001 M-11 Hallways, or aisles
WA1001 M-11 Entrances, vestibules, classrooms, for wide-angle applications
Commercial Ultrasonic Ceiling Mount Sensors
CSU600 M-13 Offices, computer, meeting, copy, and restrooms
CSU1100 M-13 Offices, lunch, break and classrooms, restrooms, and conference rooms
CSU2200 M-13 Offices, lunch, break and classrooms, restrooms, conference rooms, halls, storage areas
Commercial Dual Technology Sensors
CSD1000 M-14 Meeting, conference and classrooms, restrooms, dressing rooms, libraries,
interview rooms, testing areas, lunch and break rooms
Timers
RT1 M-17 Closets, bathroom fans, exhaust fans, heat lamps, bedrooms
RT12 M-18 Garages, basements, laundry rooms, fans, motors, landscape lights
RT24 M-18 Exterior lights, landscape lighting, security lighting, holiday lighting
97015, 30, 60 M-19 Bathroom fans, heat lamps, guest rooms
97115, 30, 60 M-19 Bathroom fans, heat lamps, guest rooms where a hold function is desired
97352 M-19 Dual control for bathroom light and fan
M-3
ApplicationsOccupancy & Vacancy Sensors & Timers
Occupancy & Vacancy Sensors & Timers
Applications
Residential Vacancy Sensors
M-4
Occupancy & Vacancy Sensors & Timers
Occupancy & Vacancy Sensors & Timers
Residential Vacancy Sensors
Passive Infrared (PIR)
Features
n California Title 24 compliant.
n Replaces a standard light or fan single pole switch.
n Lighted switch for visibility in darkened rooms.
n Manual-ON operation.
n Fixed 30-minute time delay, no adjustment
necessary.
n Low-profile styling with uniform color-matched
lens and device.
n Coverage: 180°, max. 600 ft.2 (56m2).
n cULus listed.
n 5-year warranty.
RW500B only
n Incandescent.
RWU600B only
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp.
RW500BLACC4
1.69"
2.63"
1.88"
1.69"
2.63"
1.88"
RWU600BLACC4
RW500B Wiring
Wiring for RW500B does not require a neutral.
RWU600B Wiring
Wiring for RWU600B requires a neutral.
Coverage
All devices listed on this page conform to NEMA WD-1 and WD-6.
Selectable
Catalog Auto Manual Auto/Man.
Number Description Voltage Load ON ON ON Color
Single Pole Vacancy Sensors
RW500BICC4 No Yes No Ivory
RW500BWCC4 No neutral required, 120VAC 25-500W No Yes No White
RW500BBKCC4 ideal for bedrooms 60 Hz Incandescent No Yes No Black
RW500BLACC4 and baths No Yes No Lt. Almond
RWU600BICC4 No Yes No Ivory
RWU600BWCC4 Neutral required, 120VAC 0-600W No Yes No White
RWU600BBKCC4 ideal for bedrooms 60 Hz All No Yes No Black
RWU600BLACC4 and baths No Yes No Lt. Almond
Coverage
M-5
Residential Occupancy SensorsOccupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Residential Occupancy Sensors
Passive Infrared (PIR)
Features
n Replaces a standard light or fan single pole switch.
n Lighted switch for visibility in darkened rooms.
n Automatic-ON operation.
n Fixed five-minute time delay.
n Low-profile styling with uniform color-matched
lens and device.
n Coverage: 180°, max. 600 ft.2 (56m2)
n cULus listed.
n 5-year warranty.
n Works with most common residential
lighting types
RWU600U only
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
RW500ULACC4
1.69"
2.63"
1.88"
1.69"
2.63"
1.88"
RWU600ULACC4
RW500U Wiring
Wiring for RW500U does not require a neutral.
RWU600U Wiring
Wiring for RWU600U requires a neutral.
Selectable
Catalog Auto Manual Auto/Man.
Number Description Voltage Load ON ON ON Color
Single Pole Occupancy Sensors
RW500UICC4 Yes No No Ivory
RW500UWCC4 No neutral required, 120VAC 25-500W Yes No No White
RW500UBKCC4 ideal for storage 60 Hz Incandescent Yes No No Black
RW500ULACC4 and utility rooms Yes No No Lt. Almond
RWU600UICC4 Neutral required, Yes No No Ivory
RWU600UWCC4 controls most types 120VAC 0-600W Yes No No White
RWU600UBKCC4 of lighting, ideal for 60 Hz All Yes No No Black
RWU600ULACC4 storage & utility rooms Yes No No Lt. Almond
M-6
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Coverage
RW3U600 Wiring for 3-Way Operation
Residential Occupancy/Vacancy Sensors
Occupancy & Vacancy Sensors & Timers
Residential Occupancy/Vacancy Sensors
3-Way Passive Infrared (PIR)
Applications
The RW3U600 has the flexibility to work in a variety of applications including hallways, stairways,
bathrooms, living and dining rooms, and other areas with multiple entries. The RW3U600 vacancy
sensor allows true multi-way operation with automatic ON/OFF control.
Features
n California Title 24 compliant.
n Occupancy-based control plus multi-way operation.
n Two or more RW3U600s connected together will
allow enhanced coverage of the controlled space.
n Works with most common residential lighting types.
n Adjustable time delay of 15 seconds to 30 minutes.
n Light level sensing prevents automatic ON of lights
when adequate daylight exists.
n Replaces three-way or four-way switches when used
with other RW3U600s.
n Lighted switch for visibility in darkened rooms.
n Manual- or automatic-ON operation.
n Adjustable light level setting of 10 to 150 fc
(100 to 1500 lux).
n Coverage: 180°, max. 600 ft.2 (56m2).
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
RW3U600W
shown with
SWP26W
2.8"
4.8"
1.5"
RW3U600W
Product Controls
RW3U600
Selectable Light
Catalog Auto Manual Auto/Man. Level
Number Description Voltage Load ON ON ON Color Sensing
Single Pole/3-Way Occupancy/Vacancy Sensors*
RW3U600I Light-level sensing for Yes Yes Yes Ivory Yes
RW3U600W optimum operation – 120VAC 0-600W Yes Yes Yes White Yes
RW3U600BK ideal for rooms with 60Hz All Yes Yes Yes Black Yes
RW3U600LA multiple entrances Yes Yes Yes Lt. Almond Yes
*In multi-way circuits, unit operates properly when used with other RW3U600 sensors only.
M-7
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Residential Occupancy/Vacancy Sensors
Occupancy & Vacancy Sensors & Timers
Residential Occupancy/Vacancy Sensors
Passive Infrared (PIR) with Dimmer
1.73"
2.67"
1.77"
RWDU500W
Features
n California Title 24 compliant.
n Replaces standard single pole switch or
incandescent dimmer.
n Low-profile styling with uniform color-matched
lens and device.
n Lighted pushbutton for visibility in darkened rooms.
n Manual- or automatic-ON operation.
n Adjustable time delay from 15 seconds
to 30 minutes.
n Soft start technology to prolong lamp life.
n Air gap isolation switch for safe relamping.
n If enabled, light level sensing prevents
automatic-ON when adequate daylight exists.
n Adjustable light level setting from 10-150 fc
(100-1500 lux) for daylight sensing.
n Operating conditions: 32°-104°F (0°-40°C),
95% RH, noncondensing.
n Coverage: 180°, max. 600 ft2 (56 m2).
n cULus listed.
n 5-year warranty.
Selectable
Catalog Auto Manual Auto/Man.
Number Description Voltage Load ON ON ON Color
Occupancy/Vacancy Sensors with Preset Dimmers
RWDU500I Neutral required, ideal Yes Yes Yes Ivory
RWDU500W for living, dining and 120VAC 25-500 Yes Yes Yes White
RWDU500BK family rooms, master 60Hz Incandescent Yes Yes Yes Black
RWDU500LA bathrooms and bedrooms Yes Yes Yes Lt. Almond
RWDU500 Wiring
Green
->
GROUND
Black
->
HOT (power
from circuit box)
White
->
NEUTRAL
Red
->
LOAD (power
to dimmable lamp)
De-rating
When more that one dimmer is installed
in a multi-gang box, it is necessary
to reduce the maximum load on each
dimmer.
• For an RWDU500 in either end
position of a multi-gang box, reduce
the maximum load by 50W.
• For an RWDU500 in a central position
of a multi-gang box, reduce its
maximum load by 100W. Mounting in
a deep electrical box is recommended.
Coverage
Product Controls
RWDU500
Commercial Occupancy Sensors
M-8
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors
Wall Box Passive Infrared (PIR)
Single Level Lighting
WSP200
Manual Bi-level Lighting
WSP200
WSP200
Catalog
Number Description Voltage Load Color
Automatic Wall Switches – 3 Wire Technology
WSP200I Ivory
WSP200W PIR 120/277VAC; 800W Max. at 120V White
WSP200GRY Occupancy Sensor 60 Hz 1200W Max. at 277V Gray
WSP200LA Light Almond
Features
n Detection Signature Analysis provides high
immunity to RFI and EMI.
n Compact, decorator design replaces existing
wall switch.
n Integrated light level sensor works from
10 to 150 footcandles.
n Compatible with all electronic and magnetic
ballasts, PL lamp ballasts, compact fluorescent.
n Adjustable time delay of 30 seconds to 30 minutes.
n Dual 120/277VAC operation.
n 30% to 60% energy savings.
n Positive detection indicator.
n No minimum load requirement.
n Adjustable sensitivity from 20% to 100%.
n Patented voltage drop protection.
n Patented Zero Crossing Circuitry.
n 180° coverage of up to 900 sq. ft.
n cULus listed.
n 5-year warranty.
Planning a Layout
The WSP200’s 2-level lens provides superior coverage at desktop level by allowing the sensor
to detect vertical as well as horizontal motion. Coverage shown is for walking motion. Under
optimum conditions with a high level of activity and with no barriers or obstacles, coverage can
reach a maximum of 900 square feet. Under a typical, desktop level of activity, when mounted
at 4 feet, coverage is 300 square feet.
Factory settings:
30 min. time delay,
maximum light level
and sensitivity
WSP200LA
3.272"
1.765"
3.813"
4.125"
2.610"
1.310"
Technical Specifications on Page U-127.
M-9
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Commercial Occupancy/Vacancy Sensors
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy/Vacancy Sensors
Wall Box Passive Infrared (PIR)
Features
n Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n Zero-crossing for long relay life.
n Vandal-resistant lens combines precise
coverage with durability.
n Choice of Auto-ON or Manual-ON operation.
n Auto adjustable time delays: automatic, fixed
(5, 10, 15, 20, 25 or 30 minutes), walk-through,
test-mode.
n Selectable time delay automatically adjusts
for maximum savings.
n Walk-through mode turns lifts off 3 minutes
after the area is initially occupied – ideal for
brief visits such as mail delivery.
n Selectable test mode allows quick and
easy adjustments.
n Selectable audible alert for impending shutoff.
n In AUTO-ON mode, if the sensor is manually
turned OFF, AUTO-ON will not enable until no
motion is detected for 5 minutes. This prevents the
light from turning ON when it was intended they
remain OFF. Ideal for presentations.
n LED indicates occupancy detection.
n Built-in light level sensing with simple,
one-step setup.
n Override mode allows sensor to operate as a
service switch in the unlikely event of a failure.
n NEMA WD 7 guideline utilized for coverage testing.
n Sensitivity adjustment: PIR (high/low).
n Coverage: 180°, up to 1050 sq. ft.;
major motion 35' x 30'; minor motion 20' x 15'.
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
For best performance, Pass & Seymour/Legrand
recommends using this sensor in spaces no
larger than 15' x 20'.
Occupant Selectable
Catalog Warning Auto/Man.
Number Description Rating Load Before OFF ON Color
Single-Pole Occupancy/Vacancy Sensors
OS300SI Self-adaptive 120/230/277VAC; 50/60 Hz. Yes Yes Ivory
OS300SW design remembers @ 120VAC, 0-800 W ballast All Yes Yes White
OS300SGRY ON/OFF cycles or tungsten, 1/6 hp. Yes Yes Gray
OS300SLA @ 230/277VAC, 0-1200 W ballast. Yes Yes Lt. Almond
OS300SW
1.76"
2.73"
1.83"
DIP Switch Settings
Technical Specifications on Page U-127.
Coverage
Product Controls
OS300S
ON/OFF Button
DIP Switches
Detection LED
PIR Lens
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy/Vacancy Sensors
Bi-Level Wall Box Passive Infrared (PIR)
Occupancy & Vacancy Sensors & TimersCommercial Occupancy/Vacancy Sensors
For best performance, Pass & Seymour/Legrand recommends
using this sensor in spaces no larger than 15' x 20'.
Features
n Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n Zero-crossing for long relay life.
n Vandal-resistant lens combines precise
coverage with durability.
n Choice of Auto-ON or Manual-ON operation,
selectable for each relay.
n Auto adjustable time delays: automatic,
fixed (5, 10, 15, 20, 25 or 30 minutes),
walk-through, test-mode.
n Selectable time delay automatically adjusts
for maximum savings.
n Selectable walk-through mode turns lights off
three minutes after the room is initially occupied
if no motion is detected after the first 30 seconds.
n Selectable test mode allows quick and
easy adjustments.
n Selectable audible alert for impending shutoff.
n In AUTO-ON mode, if the sensor is manually
turned OFF, AUTO-ON will not enable until no
motion is detected for 5 minutes. This prevents
the light from turning ON when it was intended
they remain OFF. Ideal for presentations.
n LED indicates occupancy detection.
n Built-in light level sensing with simple,
one-step setup.
n Override mode allows sensor to operate as a
service switch in the unlikely event of a failure.
n NEMA WD 7 guideline utilized for coverage testing.
n Sensitivity adjustment: PIR (high/low).
n Coverage: 180°, up to 1050 sq. ft.;
major motion 35' x 30'; minor motion 20' x 15'.
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp.
Coverage
Occupant Selectable
Catalog Warning Auto/Man.
Number Description Rating Load Before OFF ON Color
Single-Pole Dual-Relay Occupancy/Vacancy Sensors
OSR300SI Operates both 120/230/277VAC; 50/60 Hz. Yes Yes Ivory
OSR300SW circuits of a bi-level @ 120VAC, 0-800 W ballast All Yes Yes White
OSR300SGRY lighting system or tungsten, 1/6 hp. Yes Yes Gray
OSR300SLA @ 230/277VAC, 0-1200 W ballast. Yes Yes Lt. Almond
OSR300S Bi-Level Wiring OSR300S Two Circuit Level Wiring
M-10
DIP Switch Settings
Technical Specifications on Page U-127.
OSR300SW
1.76"
2.73"
1.83"
Product Controls
OSR300S
ON/OFF Button
DIP Switches
Detection LED
PIR Lens
M-11
Commercial Occupancy SensorsOccupancy & Vacancy Sensors & Timers
All devices listed on this page
conform to NEMA WD-1
and WD-6.
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors
Wall or Ceiling Mount Passive Infrared (PIR)
Features – WA1001 and HS1001
n Detection Signature Analysis provides high immunity
to RFI and EMI.
n 2 coverage patterns to choose from.
n Wall mount or ceiling mount.
n Adjustable sensitivity settings.
n Digital time delay from 15 seconds to 30 minutes.
n Dual-element, temperature-compensated
pyroelectric sensor.
n LED occupancy detection indicator.
n Compatible with 120VAC or 277VAC, 60 Hz
lighting systems.
n Class 2 low-voltage device.
n Positive detection indicator.
n cULus listed.
n 5-year warranty.
WA1001
HS1001
For best results, the bracket should
be used in every installation to allow
for greatest flexibility of adjustment.
Brackets are included with each unit.
2.034"
3.335"
3.367"
HS1001WA1001
Catalog Current
Number Description Voltage Draw Coverage Color
Wall/Ceiling Mount Sensors
WA1001 Wide Angle PIR 24VDC 8mA Up to 1200 sq. ft. White
Occupancy Sensor
HS1001 Long Range PIR 24VDC 8mA Up to 50 linear ft. White
Occupancy Sensor
Reference Page M-15 for Power Packs.
Wiring Diagram
Detection of motion
toward the sensor
begins at a max. of
50'. Reliable detection
occurs at 35' to 40'.
Technical Specifications on Page U-128 and U-129.
Commercial Occupancy Sensors
M-12
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors
Ceiling Mount Passive Infrared (PIR)
CS500
CS1200
2.2"
3.3"
Features
n ASIC technology reduces components and
enhances reliability.
n Pulse count processing eliminates false offs
without reducing sensitivity.
n Detection signature analysis eliminates false
triggers and proves immunity to RFI and EMI.
n Low-profile design ensures a clean and
uncluttered ceiling appearance.
n User-adjustable time delay from 15 seconds to
30 minutes by two minute increments.
n Sensitivity is programmed through a DIP switch
and has four settings from minimum to
maximum.
n Dual-element, temperature compensated pyro-
electric sensor.
n Mounting options: ceiling tile or 3.0 inch round
mudring.
n Units per power pack: up to 13.
n cULus listed.
n 5-year warranty.
Reference Page M-15 for Power Packs.
Mounting – CS1200
Override and
Catalog Output
Number Description Rating Coverage Disable Color
Low-Profile Ceiling Mount Sensors
CS500 PIR Occupancy Sensor 24VDC Input, requires 360°, 500 sq. ft. No White
CS1200 PIR Occupancy Sensor Power Pack 11mA 360°, 1200 sq. ft. No White
DIP Switch Settings
CS500/CS1200 Wiring
Technical Specifications on Page U-130.
Extended Range Lens
(Standard)
CS1200
Coverage
High Density Lens
CS500
M-13
Commercial Occupancy SensorsOccupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors
Ultrasonic Ceiling Mount
CSU1100
CSU2200
1.5"
4.8"
Features
n Advanced signal processing circuitry helps to
eliminate false ONs.
n Utilizes advanced, omni-directional (360°), Doppler
technology for reliable occupancy detection.
n Angled transmitter and receiver pairs help
optimize sensitivity while eliminating unwanted
detection from ceiling air movement.
n Digital DIP switch time delay (15 seconds to
30 minutes).
n LED indicates occupancy detection.
n Reliable solid-state construction.
n Temperature and humidity resistant 32 kHz
receivers.
n Mounts to ceiling tiles or box.
n Units per power pack: up to 4.
n cULus listed.
n 5-year warranty.
Reference Page M-15 for Power Packs.
Override and
Catalog Output
Number Description Rating Coverage Disable Color
Ultrasonic Ceiling Mount Sensors
CSU600 Ultrasonic 24VDC Input, requires 360°, 500 sq. ft. Yes White
Occupancy Sensor Power Pack 27mA One-sided
CSU1100 Ultrasonic 24VDC Input, requires 360°, 1100 sq. ft. Yes White
Occupancy Sensor Power Pack 30mA Two-sided
CSU2200 Ultrasonic 24VDC Input, requires 360°, 2200 sq. ft. Yes White
Occupancy Sensor Power Pack 30mA Two-sided
Control Output 24VDC
Common
+24VDC
Lighting
Load
White (Neutral)
Red (Load)
Red (Line)
White
BlackHot
NPOWER PACK
Red
Black
Blue
Optional
Switch
(BLU)
(RED)
(BLK)
CSU600/CSU1100/CSU2200 Wiring Coverage
Mounting
Attached to a vibration-free surface. Mount the
sensors with the receivers facing the area of coverage.
Note: Place 4' away from supply ducts, 6' from
horizontal discharge ducts, and 6" from power packs.
Technical Specifications on Page U-131.
CSU600
1.5"
4.8"
DIP Switch Settings
All devices listed on this page conform to NEMA WD-1 and WD-6.
Commercial Occupancy Sensors
Occupancy & Vacancy Sensors & Timers
Commercial Occupancy Sensors
Dual Technology Ceiling Mount
CSD1000
1.02"
4.5"
Features
n Advanced control logic based on RISC
microcontroller provides:
- Detection signature processing eliminates false
triggers and provides immunity to RFI and EMI.
n Walk-through mode turns lights off three minutes
after the area is initially occupied – ideal for brief
visits such as mail delivery.
n Available with built-in light level sensor featuring
simple, one-step setup.
n Ultrasonic diffusion technology spreads coverage
to a wider area (patented).
n LEDs indicate occupancy detection.
n Four occupancy logic options give users the ability
to customize control to meet application needs.
n Ultrasonic frequency of 40 kHz.
n Time delays: automatic, fixed (5, 10, 15, 20, or
30 minutes), walk-through, test-mode.
n Sensitivity adjustment: reduce sensitivity (for
PIR sensitivity); ultrasonic sensitivity is variable
with trimpot
n Multi-level, 360° Fresnel lens for superior
occupancy detection.
n Mounting options: ceiling tile; 4 square junction
box with double gang mudring.
n Units per power pack: up to 4.
n cULus listed.
n 5-year warranty.
Reference Page M-15 for Power Packs.
Override and
Catalog Output
Number Description Rating Coverage Disable Color
Low-Profile Ceiling Mount Sensors
CSD1000 Dual Technology 24VDC Input, requires 360°, 1000 sq. ft. Yes White
Occupancy Sensor Power Pack 35mA Two-sided
Control Output 24VDC
Common
+24VDC
Lighting
Load
White (Neutral)
Red (Load)
Red (Line)
White
BlackHot
NPOWER PACK
Red
Black
Blue
Optional
Switch
(BLU)
(RED)
(BLK)
CSD1000 Wiring
Coverage
Occupancy & Vacancy Sensors & Timers
M-14
Technical Specifications on Page U-132.
Mounting
Nut
Washer
7/8" (22mm)
hole Threaded
Insert
Ceiling
Tile
Rotate
clockwise
Ceiling
Screws:
103mm (4.1") apart
Space:
3mm/(1/8")
DIP Switch Settings
M-15
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Power Packs & Add-A-Relay
Power Packs & Add-A-Relay
A cost-effective way to power Pass & Seymour/Legrand®
occupancy sensors.
Pass & Seymour/Legrand power packs consist of a transformer and high-current relay in one small unit.
In addition to a primary high input, power packs have a secondary output of 24VDC, 100mA which
provides operating power to sensors. Upon sensing motion or insufficient light, sensors electrically close
an internal circuit and send 24VDC back to the power packs or Add-A-Relays that control lighting systems.
Unlike power packs, Add-A-Relay does not have transformer power supply, only an isolated relay.
Power packs can switch a maximum 20 Amps of fluorescent lighting. Both power packs and Add-A-Relay
are available for 120 and 277 Volt systems.
Catalog Input Load Ratings (Amps)
Number Description Voltage Ballast Incan. Motor Output
Power Packs & Add-A-Relay
PWP2120 Power Pack 120 20 13 1HP 24VDC; 150mA
PWP2277 Power Pack 277 20 — 1HP 24VDC; 150mA
AR120/277 Add-A-Relay 120/277 20 13 1HP *0
*Add-A-Relay has a current consumption of 36mA.
Installation
Power packs should be installed in accordance with state, local, and national electrical codes. They are
designed to attach to electrical enclosures with 1/2 inch knockouts. In plenum ceilings, power packs should
be installed in approved electrical enclosures. Most applications require UL listed, 18-22 AWG, 3-conductor,
class 2 cable for low-voltage wiring. For plenum rated ceilings use UL listed plenum-approved cables.
PWP2120
PWP2277
AR120/277
1.634"
2.805"
2.916" .842"
1.673"
Power Pack SchematicsJ-Box Installation
Sensor Schematic with Add-A-RelayCeiling Sensor with Power Pack
Neutral
Red
White
BlackHot
Power
Pack
Red
Blue
Switch
Black
Red
Load
Load
24VDC
Sensor
Features
n Essential to ceiling mount sensor systems.
n Self-contained transformer and relay.
n Easy-to-install.
n Teflon-coated wire leads suitable for plenum
applications.
n Secondary voltage: 24VDC;
Secondary output: 150mA.
n UL-rated 94 V0 plastic enclosure.
n cULus listed.
n 5-year warranty.
Technical Specifications
on Page U-133.
For additional Wiring
Diagrams, see
Pages U-22 & U-23.
M-16
Occupancy & Vacancy Sensors & TimersUseful Calculations
Occupancy & Vacancy Sensors & Timers
Useful Calculations
Multi-Sensor Installation
For applications requiring more than one sensor, the load per power pack should not
exceed 150mA. Use the following table to calculate the maximum number of sensors per
power pack.
Examples:
2 x CSU1100 (30mA) = 60mA 4
This is an acceptable load because it is less than 150mA.
4 x CSU1100 (30mA) + 1 x AR120/277(36mA) = 156mA 7
This is not an acceptable load because it is greater than 150mA.
Examples of savings and payback
EXAMPLE 1
Large office using a WA1001 Passive Infrared Sensor
Six 88-watt, 3-lamp fixtures = 0.528 kW x $0.086/kWh* = $0.04541/hr
Savings = 35 hours per week
Total hours saved = 1,820 hrs/yr
Annual Savings = $82.65; 5 Year Savings = $413.23
Total estimated cost including power pack: (Product and Labor) = $140.00
Payback = 20.33 months
ROI = $82.65 ÷ $140.00 = 59.03%
Individual office using a CS500 Automatic Wall Switch
Three 88-watt, 3-lamp fixtures = 0.264 kW x $0.086/kWh* = $0.02270/hr
Savings = 50 hours per week
Total hours saved = 2,600 hrs/yr
Annual Savings = $59.02; 5 Year Savings = $295.10
Total estimated cost: (Product and Labor) = $54.00
Payback = 10.98 months
ROI = $59.02 ÷ $54.00 = 109.30%
EXAMPLE 2
Restroom using a CSU1100 Ultrasonic Occupancy Sensor
Four 88-watt, 3-lamp fixtures = 0.352 kW x $0.086/kWh* = $0.03027/hr
Savings = 75 hours per week
Total hours saved = 3,900 hrs/yr
Annual Savings = $118.05; 5 Year Savings = $590.27
Total estimated cost: (Product and Labor) = $160.00
Payback = 16.26 months
ROI = $118.05 ÷ $160.00 = 73.78%
EXAMPLE 3
*Based on 2004 US Government National average cost.
WA1001 CS500/1200 HS1001 CSU600 CSU1100/2200 AR120/277 CSD1000
8mA 11mA 8mA 27mA 30mA 36mA 35mA
M-17
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Timers
Occupancy & Vacancy Sensors & Timers
Timers
Time-
Catalog Running-Out
Number Description Rating Load Warning Color
Digital Timers
RT1I No Ivory
RT1W 7-Button Digital Timer, 0-600W, 1/6 hp @ 120VAC 60 Hz All No White
RT1BK Neutral required No Black
RT1LA No Light Almond
RT1 Wiring
Features
n Seven-button preset time switch.
n Manual ON/OFF.
n Adjustable time delay: 1, 5, 10, 20, 30, 60 minutes.
n Lighted switch for visibility in darkened rooms.
n Controls most types of lighting.
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
RT1
shown with
SWP26
1.69"
2.63"
1.88"
RT1
Product Controls
RT1
Six time selection
buttons with activation
indicator lights
ON/OFF Button
M-18
Occupancy & Vacancy Sensors & Timers
All devices listed on this page conform to NEMA WD-1 and WD-6.
Timers
Occupancy & Vacancy Sensors & Timers
Timers
RT12 Wiring
Features
n Programmable countdown time switch
n Manual ON/OFF.
n Digital countdown display.
n Adjustable time delay from 5-55 minutes
(five-minute increments) to 1-12 hours
(15-minute increments).
n Audible beep and visible light flash warnings
before automatic-OFF.
n Lighted switch for visibility in darkened rooms.
n Works with most common lighting types.
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
RT12
shown with
SWP26
1.69"
2.63"
1.88"
RT12
Time-
Catalog Running-Out
Number Description Rating Load Warning Color
Digital Timers
RT12I Yes Ivory
RT12W 12-Hour Digital Timer, 0-600W, 1/6 hp @ 120VAC 60 Hz All Yes White
RT12BK Neutral required Yes Black
RT12LA Yes Light Almond
Product Controls
Features
n Manual or programmed ON/OFF switching.
n Real time clock with day/date calendar.
n Easy to read LED display.
n Programming buttons accessible without removing
wall plate.
n Eight programs can be assigned to any day or
combination of days of the week.
n Automatically calculates sunrise and sunset times
based on latitude and longitude.
n Audible or visual occupant warning
before OFF.
n Power failure memory.
n Zero crossing circuitry.
n cULus listed.
n 5-year warranty.
n Load: Incandescent, fluorescent, compact
fluorescent (CFL), magnetic low-voltage (MLV)
and electronic low-voltage (ELV), 1/6 hp
RT12
LCD Display
Lock Bar
Programming Buttons
Slide Down:
ON/OFF Button
Time-
Catalog Running-Out
Number Description Rating Load Warning Color
Astronomic Programmable Timers
RT24I 0-800W @ 120V Yes Ivory
RT24W 24-Hour 0-1200W @ 277V All Yes White
RT24BK Programmable Timer 1/6 hp @ 120/277V Yes Black
RT24LA Yes Light Almond
RT24
shown with
wall plate
Available Spring 2009.
M-19
Occupancy & Vacancy Sensors & Timers Wall Box Timers
All devices listed on this
page conform to NEMA
WD-1 and WD-6.
Occupancy & Vacancy Sensors & Timers
Wall Box Timers
125, 125-T, 250 & 277VAC, 60 Hz
97015I
2.62"
1.80"
4.20"
3.281"
1.30"
2.76"
1.85"
1.80"
Catalog Number Description Time Range Color
Specification Grade Decorator Rotary Timers
97015I Ivory
97015W Timeout, No Hold 15 Minutes White
97015LA Light Almond
97030I Ivory
97030W Timeout, No Hold 30 Minutes White
97030LA Light Almond
97060I Timeout, No Hold 60 Minutes Ivory
97060W White
97115I Timeout, With Hold 15 Minutes Ivory
97115W White
97130I Timeout, With Hold 30 Minutes Ivory
97130W White
97160I Timeout, With Hold 60 Minutes Ivory
97160W White
VAC Hz Amp HP
Ratings
125 60 20 1
125T 60 7
250 60 10 1
277 60 10
Catalog
Number Color
Replacement Knobs
(without plate)
PS55A1 White
PS55B1 Ivory
PS55G1 Light Almond
Applications
n Lighting
n Exhaust fans
n Whirlpools and spas
n Saunas
n Heating and heat lamps
n Ventilating and air conditioning
Features
n Units with “Hold” feature may be turned counter-clockwise to
hold the load on without timing function.
n Turning clockwise causes unit to time load off after desired
time delay.
n Quiet operation.
n Time range from 5 minutes to 12 hours.
n Available with or without hold.
n Decorator styling.
n Easily installed.
n Large head screw terminals.
n Accurate to ± 5 percent.
n Motor rated.
n Energy saving.
Operation:
Catalog Number 97352
n When toggle is up, one or two loads
remain on.
n When toggle is down, load “A” is off, load
“B” times-off at preset time. In the center
position, both loads are off.
Wiring Diagram: Single Timed Load Application
Catalog
Number Description Time Range Rating Color
Specification Grade Toggle Time Delay Switches
Center Off
97352I Double Pole, 1-60 Minutes, Adjustable 500W, 1/3 HP, 120VAC, 60 Hz Ivory
97352W Double Throw White
Features
n Eliminates the need for two switches.
n Fits standard toggle opening for easy ganging.
n Time range adjustable from 1-60 minutes.
n Easily installed.
n May control one or two loads simultaneously.
n Motor rated.
n Silent operation.
n Reliable solid-state construction.
n Energy saving.
97352I
4.15"
1.80"
3.281"
2.70"
1.70"
1.50"