VEEDER ROOT PETRO Gauge TLS350 Serial Interface Manual
User Manual: manual pdf -FilePursuit
Open the PDF directly: View PDF .
Page Count: 704
Download | |
Open PDF In Browser | View PDF |
VEEDER - ROOT SERIAL INTERFACE MANUAL for TLS-300 and TLS-350 UST Monitoring Systems and TLS-350R Environmental & Inventory Management System through Software Versions 020/133/333/433/520 Manual Number 576013-635 Revision AA NOTICE Veeder-Root makes no warranty of any kind with regard to this publication, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. The information contained in this publication may be subject to change without notice. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. ©Veeder-Root 2014. All rights reserved. Serial Interface Manual TLS-300/350/350R Monitoring Systems NOTICE ............................................................................................................................................................................... ii 1.0 INTRODUCTION ................................................................................................................................................... 1 2.0 HARDWARE CONNECTIONS .............................................................................................................................. 1 2.1 RS-232 ............................................................................................................................................................... 1 2.2 EIA RS-232 INTERFACE ................................................................................................................................... 1 2.3 INTERNAL MODEM........................................................................................................................................... 2 3.0 CHARACTER FORMAT AND BAUD RATE .......................................................................................................... 2 4.0 SWITCH SETTINGS .............................................................................................................................................. 2 4.1 DIP SWITCH ...................................................................................................................................................... 2 5.0 COMMAND MESSAGE FORMAT ......................................................................................................................... 3 6.0 RESPONSE MESSAGE FORMAT ........................................................................................................................ 4 6.1 COMPUTER FORMAT ...................................................................................................................................... 4 6.2 DISPLAY FORMAT ............................................................................................................................................ 4 6.3 ASCII FLOATING POINT FORMAT .................................................................................................................. 5 6.3.1 NOTES ....................................................................................................................................................... 5 6.3.2 EXAMPLES ................................................................................................................................................ 6 7.0 FUNCTION CODES AND RESPONSE MESSAGES ............................................................................................ 7 7.1 CONTROL FUNCTIONS ........................................................................................................................................ 9 7.2 OPERATIONAL REPORTS .................................................................................................................................. 37 7.2.1 SYSTEM REPORTS ..................................................................................................................................... 37 7.2.2 IN-TANK REPORTS...................................................................................................................................... 58 7.2.3 SENSOR REPORTS ................................................................................................................................... 101 7.2.4 LINE LEAK REPORTS ................................................................................................................................ 123 7.2.5 MISCELLANEOUS REPORTS ................................................................................................................... 142 7.2.6 I/O DEVICE REPORTS ............................................................................................................................... 145 7.3 SETUP FUNCTIONS & REPORTS .................................................................................................................... 152 7.3.1 SYSTEM SETUP ......................................................................................................................................... 152 7.3.2 COMMUNICATIONS SETUP ...................................................................................................................... 181 7.3.3 WARNING, ALARM, & AUTO-PRINT SETUP ............................................................................................ 202 7.3.4 IN-TANK SETUP ......................................................................................................................................... 244 7.3.5 SENSOR SETUP ........................................................................................................................................ 314 7.3.6 VOLUMETRIC LINE LEAK SETUP ............................................................................................................. 347 7.3.7 PUMP SENSOR SETUP ............................................................................................................................. 366 7.3.8 PRESSURE LINE LEAK SETUP................................................................................................................. 372 7.3.9 RECONCILIATION SETUP ......................................................................................................................... 403 7.3.10 WIRELESS PLLD SETUP ......................................................................................................................... 419 7.3.11 METER MAP & DELIVERY TICKET SETUP ............................................................................................ 435 7.3.12 PUMP MONITOR RELAY SETUP ............................................................................................................ 442 7.3.13 I/O DEVICE SETUP .................................................................................................................................. 448 7.3.14 EEPROM SETUP ...................................................................................................................................... 462 7.3.15 MISCELLANEOUS SETUP ....................................................................................................................... 465 7.4 DIAGNOSTIC REPORTS ................................................................................................................................... 483 7.4.1 SYSTEM DIAGNOSTIC REPORTS ............................................................................................................ 483 7.4.2 IN-TANK DIAGNOSTIC REPORTS ............................................................................................................ 489 7.4.3 SENSOR DIAGNOSTIC REPORTS ........................................................................................................... 519 7.4.4 LINE LEAK DIAGNOSTIC REPORTS ........................................................................................................ 537 7.4.5 RECONCILIATION DIAGNOSTIC REPORTS ............................................................................................ 564 7.5 RECONCILIATION REPORTS ........................................................................................................................... 570 7.6 VARIANCE ANALYSIS REPORTS..................................................................................................................... 585 7.7 IN-STATION DIAGNOSTICS (ISD) .................................................................................................................... 598 7.7.1 ISD REPORTS ............................................................................................................................................ 598 7.7.2 ISD SETUP.................................................................................................................................................. 635 7.7.3 ISD DIAGNOSTIC REPORTS..................................................................................................................... 653 8.0 IFSF DATABASE SUPPORT .................................................................................................................................. 675 8.1 TANK LEVEL GAUGE DATABASE .................................................................................................................... 675 Part No. 576013-635, Revision AA iii Serial Interface Manual TLS-300/350/350R Monitoring Systems 8.2 TANK LEVEL GAUGE ERROR CODE DATABASE .......................................................................................... 676 8.3 TANK PROBE DATABASE ................................................................................................................................ 676 8.4 TANK CONTENTS TABLE DATABASE ............................................................................................................. 678 8.5 TANK TEMPERATURE TABLE DATABASE ..................................................................................................... 678 8.6 TANK PROBE ERROR CODE DATABASE ....................................................................................................... 678 8.7 DATA DOWNLOAD DATABASE........................................................................................................................ 679 8.8 COMMUNICATION SERVICE DATABASE........................................................................................................ 679 9.0 FUNCTION CODE SUMMARY ............................................................................................................................... 680 CONTROL FUNCTIONS (7.1) ................................................................................................................................... 680 OPERATIONAL REPORTS (7.2) .............................................................................................................................. 681 SYSTEM REPORTS (7.2.1) .................................................................................................................................. 681 IN-TANK REPORTS (7.2.2) .................................................................................................................................. 681 SENSOR REPORTS (7.2.3) ................................................................................................................................. 682 LINE LEAK REPORTS (7.2.4) .............................................................................................................................. 683 MISCELLANEOUS REPORTS (7.2.5) .................................................................................................................. 683 I/O DEVICE REPORTS (7.2.6) ............................................................................................................................. 684 SETUP FUNCTIONS & REPORTS (7.3) .................................................................................................................. 684 SYSTEM SETUP (7.3.1) ....................................................................................................................................... 684 COMMUNICATIONS SETUP (7.3.2) .................................................................................................................... 685 WARNING, ALARM, & AUTO-PRINT SETUP (7.3.3) .......................................................................................... 685 IN-TANK SETUP (7.3.4)........................................................................................................................................ 687 SENSOR SETUP (7.3.5) ....................................................................................................................................... 689 VOLUMETRIC LINE LEAK SETUP (7.3.6) ........................................................................................................... 690 PUMP SENSOR SETUP (7.3.7) ........................................................................................................................... 690 PRESSURE LINE LEAK SETUP (7.3.8) ............................................................................................................... 691 RECONCILIATION SETUP (7.3.9) ....................................................................................................................... 691 WIRELESS PLLD SETUP (7.3.10) ....................................................................................................................... 692 METER MAP & DELIVERY TICKET SETUP (7.3.11)........................................................................................... 692 LINE/PLLD/WPLLD SETUP .................................................................................................................................. 693 PUMP MONITOR RELAY SETUP (7.3.12) ........................................................................................................... 693 PRESSURE LINE LEAK SETUP (refer to 7.3.8) ................................................................................................... 693 PUMP SENSOR SETUP (refer to 7.3.7) ............................................................................................................... 693 I/O DEVICE SETUP (7.3.13) ................................................................................................................................. 693 EEPROM SETUP (7.3.14) .................................................................................................................................... 694 MISCELLANEOUS SETUP (7.3.15) ..................................................................................................................... 694 DIAGNOSTIC REPORTS (7.4) ................................................................................................................................. 695 SYSTEM DIAGNOSTIC REPORTS (7.4.1) .......................................................................................................... 695 IN-TANK DIAGNOSTIC REPORTS (7.4.2) ........................................................................................................... 695 SENSOR DIAGNOSTIC REPORTS (7.4.3) .......................................................................................................... 696 LINE LEAK DIAGNOSTIC REPORTS (7.4.4) ....................................................................................................... 696 RECONCILIATION DIAGNOSTIC REPORTS (7.4.5) .......................................................................................... 697 VARIANCE ANALYSIS REPORTS (7.6) ................................................................................................................... 698 IN-STATION DIAGNOSTICS (ISD) (7.7)................................................................................................................... 698 ISD REPORTS (7.7.1) ........................................................................................................................................... 698 ISD SETUP (7.7.2) ................................................................................................................................................ 698 ISD DIAGNOSTIC REPORTS (7.7.3) ................................................................................................................... 699 Part No. 576013-635, Revision AA iv Serial Interface Manual TLS-300/350/350R Monitoring Systems 1.0 INTRODUCTION The serial RS-232 interface is used to connect the system to a controlling computer, a display terminal (CRT) or a printing terminal. A modem can be connected directly to the system to provide telephone line access. NOTE: The software versions for these systems vary depending on when they were purchased and if software upgrades have been installed. The version in which each function code first appeared is indicated in a box next to its description in Section 7. Commands appearing in software versions greater than 100 are only active in systems equipped with an ECPU. 2.0 HARDWARE CONNECTIONS The RS-232 interface is a module accessed via a 25-pin D-connector located on the bottom-left of the console. 2.1 RS-232 The RS-232 D-connector is a panel mount, 25-pin female type, wired in a Data Terminal Equipment (DTE) configuration. A modem (DCE) may be connected directly to the interface using a straightthrough cable. A CRT or printing terminal (DTE) may be connected to the interface by using a null cable which reverses the sense of the transmit/receive signals. The system does not require or activate any handshake signals. RS-232 signals are wired to the female D-connector as follows: PIN 2 3 7 2.2 Transmitted Data Received Data Signal Ground (common return) and Chassis EIA RS-232 INTERFACE The EIA RS-232 interface is designed to connect to modems for transmission of data over telephone lines. It can be used for direct local attachment of terminals if the cable run is no more than 50 feet. In practice, cable runs longer than 50 feet have performed satisfactorily; however, since the RS-232 specification is designed for operation up to 50 feet, direct connect cable runs greater than 50 feet are not warranted for proper operation. Part No. 576013-635, Revision AA 1 Serial Interface Manual TLS-300/350/350R Monitoring Systems 2.3 INTERNAL MODEM The optional internal modem operates at up to 2400 Baud. The modem module contains two RJ11 jacks for phone line connections, and is accessible at the bottom left of the console. 3.0 CHARACTER FORMAT AND BAUD RATE The system receives and sends characters via the RS-232 interface in an ASCII format that is configured via the system front panel keypads. Selections consist of: 1 start bit; 7 or 8 data bits; odd, even or no parity; and 1 or 2 stop bits. Communications rate is selectable: 300, 1200, 2400, 4800 or 9600 baud. The system operates in a full duplex mode. Characters are not echoed when received, and transmitted characters must not be echoed back to the system. Transmit and receive can occur simultaneously, and commands can be stacked in the system buffer (up to 128 characters). 4.0 SWITCH SETTINGS 4.1 DIP SWITCH A four-position DIP switch is located on the CPU board, which is mounted in the right-back of the console printer compartment. The DIP switch is next to the battery switch. The DIP switch positions are assigned as follows: Switch 1 Front Panel Setup Security Enable 2 RS-232 Security Enable 3 Unused 4 Fiscal Height Security Part No. 576013-635, Revision AA 2 Serial Interface Manual TLS-300/350/350R Monitoring Systems 5.0 COMMAND MESSAGE FORMAT All command and response messages are configured in a format which includes a surrounding envelope of control characters and a function code and data field message. The control characters are described in this section while the function codes and data field messages are described in subsequent sections. The system responds to a command message that has the following configuration: SOH Security Code Function Code Data Field SOH is a control-A character (ASCII 01). The RS-232 security code is an optional six-digit code used to limit external serial access to the system for security purposes. It can be set to any unique set of characters using either the front panel switches or the external communication interface setup commands. The system will not respond to a command without the proper security code, if the DIP switch is set to enable RS-232 security. The function code is a six character command code which the system interprets to determine the type of action to take and response to return. System function codes and response messages are defined in subsequent sections. The data field is optional and contains information necessary to perform the selected function (such as setup information). If the system receives a command message string containing a function code that it does not recognize, it will respond with a9999FF1B . The "9999" indicates that the system has not understood the command, while the "FF1B" is the appropriate checksum for the preceding 9999 string. There is one command which does not follow the above format. The escape command is performed by sending an ESC (escape character, ASCII 27), to the system. It is a means to halt a response message at any time before its completion. Part No. 576013-635, Revision AA 3 Serial Interface Manual TLS-300/350/350R Monitoring Systems 6.0 RESPONSE MESSAGE FORMAT There are two types of response message formats: computer (or packed data format) and display format. Each format uses a different surrounding envelope of control characters. 6.1 COMPUTER FORMAT The computer format is a stream of numbers without any formatting characters; i.e., carriage return, line feed, spaces, labels, etc. The message format is as follows: SOH Function Code Data Field && Checksum ETX The function code is identical to the received command message function code. The data field contains the response message which is described in subsequent sections. The "&&" is a fixed tag character which indicates that the checksum immediately follows. The Checksum is a series of four ASCII-hexadecimal characters which provide a check on the integrity of all the characters preceding it, including the control characters. The four characters represent a 16-bit binary count which is the 2's complemented sum of the 8-bit binary representation of the message characters after the parity bit (if enabled) has been cleared. Overflows are ignored. The data integrity check can be done by converting the four checksum characters to the 16-bit binary number and adding the 8-bit binary representation of the message characters to it. The binary result should be zero. ETX is programmable if enabled via the S53100f command. If it is disabled, the ETX is a fixed Control-C character (ASCII 03). Caution should be taken before changing the ETX character, because it affects the transmitted messages on ALL communications ports of the system, and additional host devices may be connected to other ports which expect the ETX to be a Control-C. 6.2 DISPLAY FORMAT The display format is intended for display on a CRT or printer. It includes all the necessary formatting characters such as carriage returns, line feeds, nulls, spaces, labels, etc. The message format is as follows: SOH Function Code Data Field ETX See subsequent sections for a description of the data field response messages. Part No. 576013-635, Revision AA 4 Serial Interface Manual TLS-300/350/350R Monitoring Systems 6.3 ASCII FLOATING POINT FORMAT 6.3.1 NOTES 6.3.1.1 HHHHHHHH (H = 0-9 or A-F) indicates the 8 "nibble" ASCII-Hexadecimal representation of a 4-Byte Floating Point number. Many data parameters are transmitted in this format. 6.3.1.2 The 32-bits are arranged as follows: Byte Nibble 1 2 3 4 S EEE EEEE E MMM MMMM MMMM MMMM MMMM MMMM 1 2 3 4 5 6 7 8 S is the sign bit (0 if positive, 1 if negative). EEE EEEE E represents the 2's exponent. It is a 2's complement value biased by 127 (7F Hex). The exponent can be determined by subtracting 127 from the value of the E field and raising 2 to the resulting power. MMM MMMM MMMM MMMM MMMM MMMM represents the 23-bit mantissa. Since the mantissa describes a value which is greater than or equal to 1.0 and less than 2.0, the 24th bit is always assumed to be equal to 1 and is not transmitted or stored. The value23of the mantissa can be determined by dividing the value of the M field by 8,388,608 (2 ) and adding 1.0. 6.3.1.3 The complete value of the floating point number can then be determined by multiplying the exponent by the mantissa and attaching the appropriate positive or negative sign. 6.3.1.4 By convention, 00 00 00 00 represents the value 0.0 even though it actually converts to 5.8775 x 10-39. 6.3.1.5 The eight "nibbles" are transmitted in sequence from 1 through 8 as shown in section 6.3.1.2. Part No. 576013-635, Revision AA 5 Serial Interface Manual TLS-300/350/350R Monitoring Systems 6.3.2 EXAMPLES 6.3.2.1 3F800000 hex = 0011 1111 1000 0000 0000 0000 0000 0000 bin S = 0 = + (positive) E = 011 1111 1 bin = 7F hex = 127 dec M = 000 0000 0000 0000 0000 0000 bin = 0 hex = 0 dec Exponent = 2(127-127) = 1.0 Mantissa = 1.0 + (0/8,388,608) = 1.0 Decimal Value = +1.0 x 1.0 = 1.0 6.3.2.2 B8D1B717 hex = 1011 1000 1101 0001 1011 0111 0001 0111 bin S = 1 = - (negative) E = 011 1000 1 bin = 71 hex = 113 dec M = 101 0001 1011 0111 0001 0111 bin = 51 B7 17 hex = 5,355,287 dec Exponent = 2(113-127) = 0.0000610352 Mantissa = 1.0 + (5,355,287/8,388,608) = 1.63840 Decimal Value = -0.0000610352 x 1.63840 = -0.0001 6.3.2.3 C2C7FAE1 hex = 1100 0010 1100 0111 1111 1010 1110 0001 bin S = 1 = - (negative) E = 100 0010 1 bin = 85 hex = 133 dec M = 100 0111 1111 1010 1110 0001 bin = 47 FA E1 hex = 4,717,281 dec Exponent = 2(133-127) = 64 Mantissa = 1.0 + (4,717,281/8,388,608) = 1.56234 Decimal Value = -64 x 1.56234 = -99.99 6.3.2.4 461C4000 hex = 0100 0110 0001 1100 0100 0000 0000 0000 bin S = 0 = + (positive) E = 100 0110 0 bin = 8C hex = 140 dec M = 001 1100 0100 0000 0000 0000 bin = 1C 40 00 hex = 1,851,392 dec Exponent = 2(140-127) = 8,192 Mantissa = 1.0 + (1,851,392/8,388,608) = 1.22070 Decimal Value = +8,192 x 1.22070 = 10,000 Part No. 576013-635, Revision AA 6 Serial Interface Manual TLS-300/350/350R Monitoring Systems 7.0 FUNCTION CODES AND RESPONSE MESSAGES All response messages are sent in a format described in previous sections. The function codes and data fields of these message formats are described in this section. The data field response messages are divided into the following major groupings: Function Codes ................................................................................................................. Response Types 001 to 09B .........................................................................................................................Control Functions 101 to 132 ...................................................................................................... Operational Reports (System) 201 to 2E2 ...................................................................................................... Operational Reports (In-tank) 301 to 34C ....................................................................................................... Operational Reports (Sensor) 351 to 389 ................................................................................................. Operational Reports (Line Leak) 391 to 392 ...........................................................................................Operational Reports (Miscellaneous) 401 to 412 ................................................................................................ Operational Reports (I/O Device) 501 to 51E ........................................................................................... Setup Functions & Reports (System) 520 to 531 ........................................................................... Setup Functions & Reports (Communications) 532 to 5E2 ..................................................... Setup Functions & Reports (Warning, Alarm, & Auto-print) 601 to 683 ........................................................................................... Setup Functions & Reports (In-tank) 701 to 74E ............................................................................................Setup Functions & Reports (Sensor) 751 to 7BC .................................................................. Setup Functions & Reports (Volumetric Line Leak) 771 to 7DC ................................................................................ Setup Functions & Reports (Pump Sensor) 774 to 7D9........................................................................ Setup Functions & Reports (Pressure Line Leak) 790 to 79F ............................................................................... Setup Functions & Reports (Reconciliation) 7A0 to 7BE ............................................................................ Setup Functions & Reports (Wireless PLLD) 7B1 to 7B6 ......................................................Setup Functions & Reports (Meter Map & Delivery Ticket) 7C4 to 7C9 .................................................................... Setup Functions & Reports (Pump Monitor Relay) 801 to 813 ..................................................................................... Setup Functions & Reports (I/O Device) 851 to 853 ...................................................................................... Setup Functions & Reports (EEPROM) 881 to 8C4 ............................................................................... Setup Functions & Reports (Miscellaneous) 901 to 908 ....................................................................................................... Diagnostic Reports (System) A01 to A91....................................................................................................... Diagnostic Reports (In-tank) B01 to B4B ...................................................................................................... Diagnostic Reports (Sensor) B50 to B8E .................................................................................................. Diagnostic Reports (Line Leak) B91 to BB1 .......................................................................................... Diagnostic Reports (Reconciliation) C01 to C09 ................................................................................................................ Reconciliation Reports C10 to C25 .......................................................................................................... Variance Analysis Reports V00 to V12................................................................................................. In-Station Diagnostics (Reports) V40 to V52.................................................................................................... In-Station Diagnostics (Setup) V80 to XE0 ......................................................................................... In-Station Diagnostics (Diagnostics) Part No. 576013-635, Revision AA 7 Serial Interface Manual TLS-300/350/350R Monitoring Systems Most response messages can be requested for either a single device (tank, sensor, line, etc.) or all devices. A "TT" in the function code signifies single device number 01 through 16. When "TT" is 00, it signifies all devices. Typically, response messages include information on the active devices only. That is, those devices that are connected and working. However, the system can be forced to send data on inactive devices by using an inactive device number. In this case, if no valid data is available on a device, the message is filled out with question marks (?) in the place of numbers. Computer format response messages do not include any formatting characters such as carriage returns, line feeds, spaces, nulls, labels, etc. Only those characters shown are actually included in the response message. For convenience, the messages are shown in segments and do not actually include any line feeds, carriage returns, etc. Also, the notes to the right and between the message lines are not included in the messages. All number values contained in the response messages retain leading zeroes. Display format response messages include the formatting characters shown. All message lines end with a carriage return, line feed and six nulls. All response messages start and end with at least one blank line. The system function codes and response messages are described in detail in the following sections under the major headings given above. A summary list of all function codes is given at the end of this document. Part No. 576013-635, Revision AA 8 Serial Interface Manual TLS-300/350/350R Monitoring Systems 7.1 CONTROL FUNCTIONS Function Code: 001 Function Type: System Reset Version 1 Command Format: Display: S00100 Computer: s00100 Typical Response Message, Display Format: S00100 MAR 27, 1996 4:47 PM Typical Response Message, Computer Format: s00100YYMMDDHHmm&&CCCC Notes: 1. 2. 3. YYMMDDHHmm - Current Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 9 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 002 Function Type: Clear Power Reset Flag Version 1 Command Format: Display: S00200 Computer: s00200 Typical Response Message, Display Format: S00200 MAR 27, 1996 8:06 PM Typical Response Message, Computer Format: s00200YYMMDDHHmm&&CCCC Notes: 1. 2. 3. YYMMDDHHmm - Current Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 10 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 003 Function Type: Remote Alarm Reset Version 1 Command Format: Display: S00300 Computer: s00300 Typical Response Message, Display Format: S00300 MAR 27, 1996 8:04 PM Typical Response Message, Computer Format: s00300YYMMDDHHmm&&CCCC Notes: 1. 2. 3. YYMMDDHHmm - Current Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 11 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 010 Function Type: Cancel Autodial Computer Mode Session Version 14 Command Format: Display: S01000 Computer: s01000 Typical Response Message, Display Format: S01000 MAR 27, 1996 8:04 PM Typical Response Message, Computer Format: s00300YYMMDDHHmm&&CCCC Notes: 1. 2. 3. YYMMDDHHmm - Current Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 12 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 031 Function Type: Confirm Clear Function Version 10 Command Format: Display: S03100832382 Computer: s03100832382 Typical Response Message, Display Format: S03100 MAR 29, 1996 6:27 PM CONFIRM CLEAR COMPLETE Typical Response Message, Computer Format: s03100YYMMDDHHmm&&CCCC Notes: 1. 2. 3. YYMMDDHHmm - Current Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 13 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 051 Function Type: Clear In-Tank Delivery Reports Version 1 Command Format: Display: S051TT Computer: s051TT Typical Response Message, Display Format: S051TT MAR 29, 1996 6:27 PM DELIVERY REPORTS ERASED Typical Response Message, Computer Format: s051TTYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm TT && CCCC - Current Date and Time Tank Number (Decimal, 00=all) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 14 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 052 Function Type: Start In-Tank Leak Detect Test Version 1 Command Format: Display: S052TT Computer: s052TT Typical Response Message, Display Format: S052TT MAR 27, 1996 TANK 1 6:28 PM PRODUCT LABEL UNLEADED REGULAR LEAK TEST START TEST BY EXTERN INTERFACE Typical Response Message, Computer Format: s052TTYYMMDDHHmmTTk&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time TT - Tank Number (Decimal, 00=all) k - Status Flag 0=OFF 1=ON && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 15 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 053 Function Type: Stop In-Tank Leak Detect Test Version 1 Command Format: Display: S053TT Computer: s053TT Typical Response Message, Display Format: S053TT MAR 29, 1996 TANK 1 6:27 PM PRODUCT LABEL REGULAR UNLEADED LEAK TEST STOP Typical Response Message, Computer Format: s053TTYYMMDDHHmmTTk&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time TT - Tank Number (Decimal, 00=all) k - Status Flag 0=OFF 1=ON && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 16 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 054 Function Type: Delete CSLD Rate Table Version 5 Command Format: Display: S054TT149 Computer: s054TT149 Notes: 1. 2. TT - Tank Number (command valid for single tank only) 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S054TT MAR 29, 1996 6:27 PM T 1:REGULAR UNLEADED CSLD RECORDS DELETED Typical Response Message, Computer Format: s054TTYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm TT && CCCC - Current Date and Time Tank Number Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 17 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 081 Version 7 Function Type: Start Pressure Line Leak Test (3.00 GPH only in V18) Command Format: Display: S081QQ149 Computer: s081QQ149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S081QQ MAR 29, 1996 6:27 PM Q 1:REGULAR UNLEADED STATUS: TEST COMPLETE Typical Response Message, Computer Format: s081QQYYMMDDHHmmQQtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak sensor number (Decimal, 00=All) tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.10 gal/hr 04=test aborted 05=running pump (manual test starting) 06=line lockout 07=disable alarm 08=test pending 09=testing delay 0A=pressure check 0B=testing at 0.20 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 18 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 082 Function Type: Stop Pressure Line Leak Test Version 7 Command Format: Display: S082QQ149 Computer: s082QQ149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S082QQ MAR 29, 1996 6:27 PM Q 1:REGULAR UNLEADED STATUS: TEST COMPLETE Typical Response Message, Computer Format: s082QQYYMMDDHHmmQQtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak sensor number (Decimal, 00=All) tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.10 gal/hr 04=test aborted 05=running pump (manual test starting) 06=line lockout 07=disable alarm 08=test pending 09=testing delay 10=pressure check 11=testing at 0.20 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 19 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 083 Version 10 Function Type: Start WPLLD Line Leak Test (3.00 GPH only in V18) Command Format: Display: S083WW149 Computer: s083WW149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S083WW MAR 27, 1996 3:47 PM W 1:UNLEADED REGULAR STATUS: TEST PENDING Typical Response Message, Computer Format: s083WWYYMMDDHHmmWWtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time WW - WPLLD Line Leak sensor number (Decimal, 00=All) tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.20 gal/hr 04=test aborted 05=line lockout 06=disable alarm 07=test pending 08=test delay 09=testing at 0.10 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 20 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 084 Function Type: Stop WPLLD Line Leak Test Version 10 Command Format: Display: S084WW149 Computer: s084WW149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S084WW MAR 27, 1996 3:48 PM W 1:UNLEADED REGULAR STATUS: TEST ABORTED Typical Response Message, Computer Format: s084WWYYMMDDHHmmWWtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time WW - WPLLD Line Leak sensor number (Decimal, 00=All) tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.20 gal/hr 04=test aborted 05=line lockout 06=disable alarm 07=test pending 08=test delay 09=testing at 0.10 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 21 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 087 Function Type: Start Pressure Line Leak Test by Type Version 18 Command Format: Display: S087QQ149rr Computer: s087QQ149rr Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S087QQ MAR 29, 1999 6:27 PM Q 1:REGULAR UNLEADED 0.2 GPH SCHEDULED STATUS: TEST COMPLETE Typical Response Message, Computer Format: s087QQYYMMDDHHmmQQrrtt&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak sensor number (Decimal, 00=All) rr - Test Type 01=0.10 GPH 02=0.20 GPH 03=3.00 GPH tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.10 gal/hr 04=test aborted 05=running pump (manual test starting) 06=line lockout 07=disable alarm 08=test pending 09=testing delay 0A=pressure check 0B=testing at 0.20 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 22 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 088 Function Type: Start WPLLD Line Leak Test by Type Version 18 Command Format: Display: S088WW149rr Computer: s088WW149rr Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S088WW MAR 29, 1999 6:27 PM W 1:REGULAR UNLEADED 0.2 GPH SCHEDULED STATUS: TEST COMPLETE Typical Response Message, Computer Format: s088WWYYMMDDHHmmWWrrtt&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm - Current Date and Time WW - WPLLD Line Leak sensor number (Decimal, 00=All) rr - Test Type 01=0.10 GPH 02=0.20 GPH 03=3.00 GPH tt - Test status 00=test complete 01=dispensing 02=testing at 3.00 gal/hr 03=testing at 0.20 gal/hr 04=test aborted 05=line lockout 06=disable alarm 07=test pending 08=test delay 09=testing at 0.10 gal/hr && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 23 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 089 Function Type: Pressure Line Leak Pressure Offset Reset Version 19 Command Format: Display: S089QQ149 Computer: s089QQ149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S089QQ JAN 1, 2000 6:27 PM Q 1:REGULAR UNLEADED PRESSURE OFFSET RESET Typical Response Message, Computer Format: s089QQYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm QQ && CCCC - Current Date and Time Pressure Line Leak sensor number (Decimal, 00=All) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 24 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 090 Function Type: WPLLD Line Leak Pressure Offset Reset Version 19 Command Format: Display: S090WW149 Computer: s090WW149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S090WW JAN 1, 2000 6:27 PM W 1:REGULAR UNLEADED PRESSURE OFFSET RESET Typical Response Message, Computer Format: s090WWYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm WW && CCCC - Current Date and Time WPLLD Line Leak sensor number (Decimal, 00=All) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 25 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 091 Function Type: Close Current Shift Version 15 Command Format: Display: S09100 Computer: s09100 Typical Response Message, Display Format: S09100 MAR 27, 1996 8:04 PM CLOSE CURRENT SHIFT: YES Typical Response Message, Computer Format: s09100YYMMDDHHmmff&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm - Current Date and Time ff - Close Current Shift Flag 01=If close accepted && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 26 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 092 Function Type: Start Pressure Line Leak Profile Line Test Version 23 Command Format: Display: S092QQ149 Computer: s092QQ149 Notes: 1. 149 - This verification code must be sent to confirm the comand Typical Response Message, Display Format: I092QQ NOV 14, 2001 10:15 PM START PRESSURE LINE LEAK PROFILE LINE TEST Q 1:UNLEADED REGULAR STATUS: RUNNING PUMP Typical Response Message, Computer Format: s092QQYYMMDDHHmmQQtt QQtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak Sensor Number (Decimal, 00 = all) tt - Test Status 00 = TEST COMPLETE (DONE: BULK MOD 10000) 01 = TURN PUMP ON (RUNNING PUMP) 02 = PUMP ON WAIT (RUNNING PUMP) 03 = PRESSURE 1 WAIT (PUMP OFF) 04 = PRESSURE 2 WAIT (MEASURING Pxx 19.123 PSI) 05 = CALC WAIT TIME (MEASURING Pxx 19.123 PSI) 06 = PRESSURE N WAIT (MEASURING Pxx 19.123 PSI) 07 = EVALUATE PERIOD (MEASURING Pxx 19.123 PSI) 08 = TEST ABORT (ABORTED) && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 27 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 093 Function Type: Stop Pressure Line Leak Profile Line Test Version 23 Command Format: Display: S093QQ149 Computer: s093QQ149 Notes: 1. 149 - This verification code must be sent to confirm the comand Typical Response Message, Display Format: I093QQ NOV 14, 2001 10:15 PM STOP PRESSURE LINE LEAK PROFILE LINE TEST Q 1:UNLEADED REGULAR STATUS: ABORTED Typical Response Message, Computer Format: s093QQYYMMDDHHmmQQtt QQtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak Sensor Number (Decimal, 00 = all) tt - Test Status 00 = TEST COMPLETE (DONE: BULK MOD 10000) 01 = TURN PUMP ON (RUNNING PUMP) 02 = PUMP ON WAIT (RUNNING PUMP) 03 = PRESSURE 1 WAIT (PUMP OFF) 04 = PRESSURE 2 WAIT (MEASURING Pxx 19.123 PSI) 05 = CALC WAIT TIME (MEASURING Pxx 19.123 PSI) 06 = PRESSURE N WAIT (MEASURING Pxx 19.123 PSI) 07 = EVALUATE PERIOD (MEASURING Pxx 19.123 PSI) 08 = TEST ABORT (ABORTED) && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 28 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 094 Version 23 Function Type: Recalculate Pressure Line Leak Profile Bulk Modulus Command Format: Display: S094QQ149 Computer: s094QQ149 Notes: 1. 149 - This verification code must be sent to confirm the comand Typical Response Message, Display Format: I094QQ NOV 14, 2001 10:15 PM RECALCULATE PRESSURE LINE LEAK PROFILE LINE TEST BULK MODULUS Q 1:UNLEADED REGULAR STATUS: DONE: BULK MOD 10000 Typical Response Message, Computer Format: s094QQYYMMDDHHmmQQtt QQtt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time QQ - Pressure Line Leak Sensor Number (Decimal, 00 = all) tt - Test Status 00 = TEST COMPLETE (DONE: BULK MOD 10000) 01 = TURN PUMP ON (RUNNING PUMP) 02 = PUMP ON WAIT (RUNNING PUMP) 03 = PRESSURE 1 WAIT (PUMP OFF) 04 = PRESSURE 2 WAIT (MEASURING Pxx 19.123 PSI) 05 = CALC WAIT TIME (MEASURING Pxx 19.123 PSI) 06 = PRESSURE N WAIT (MEASURING Pxx 19.123 PSI) 07 = EVALUATE PERIOD (MEASURING Pxx 19.123 PSI) 08 = TEST ABORT (ABORTED) && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 29 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 095 Function Type: Start Vacuum Sensor Manual Test Version 24 Command Format: Display: S095SS149 Computer: s095SS149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S095SS FEB 14, 2004 10:15 AM START VACUUM SENSOR MANUAL TEST s 1:VACUUM SENSOR #1 MANUAL TEST STARTED Typical Response Message, Computer Format: s095SSYYMMDDHHmmSStt... SStt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time SS - Smart Sensor Number (Decimal, 00=all) tt - Manual Test Status 00=ABORTED 01=STARTED 02=PENDING && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 30 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 096 Function Type: Stop Vacuum Sensor Manual Evacuation Test Version 24 Command Format: Display: S096SS149 Computer: s096SS149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S096SS FEB 14, 2004 10:15 AM STOP VACUUM SENSOR MANUAL EVACUATION TEST s 1:VACUUM SENSOR #1 MANUAL TEST ABORTED Typical Response Message, Computer Format: s096SSYYMMDDHHmmSStt... SStt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time SS - Smart Sensor Number (Decimal, 00=all) tt - Manual Test Status 00=ABORTED 01=STARTED 02=PENDING && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 31 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 097 Function Type: Start Vacuum Sensor Evacuation Hold Version 24 Command Format: Display: S097SS149 Computer: s097SS149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S097SS FEB 14, 2004 10:15 AM START VACUUM SENSOR EVACUATION HOLD s 1:VACUUM SENSOR #1 EVAC HOLD STARTED EVACUATION STATE: EVAC_HOLD Typical Response Message, Computer Format: s097SSYYMMDDHHmmSSEE... SSEE&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time SS - Smart Sensor Number (Decimal, 00=all) EE - Evacuation State (Hex) 00=Vacuum Ok 01=Evacuation Pending 02=Evacuation Active 03=Evacuation Pending Manual 04=Evacuation Active Manual 05=No Vacuum 06=Evacuation Hold && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 32 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 098 Function Type: Stop Vacuum Sensor Evacuation Hold Version 24 Command Format: Display: S098SS149 Computer: s098SS149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S098SS FEB 14, 2004 10:15 AM STOP VACUUM SENSOR EVACUATION HOLD s 1:VACUUM SENSOR #1 EVAC HOLD ABORTED EVACUATION STATE: VACUUM OK Typical Response Message, Computer Format: s098SSYYMMDDHHmmSSEE... SSEE&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time SS - Smart Sensor Number (Decimal, 00=all) EE - Evacuation State (Hex) 00=Vacuum Ok 01=Evacuation Pending 02=Evacuation Active 03=Evacuation Pending Manual 04=Evacuation Active Manual 05=No Vacuum 06=Evacuation Hold && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 33 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 099 Function Type: Start Mag Sump Leak Test Version 26 Command Format: Display: S099ss149 Computer: s099ss149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S099ss FEB 14, 2004 10:15 AM START MAG SUMP LEAK TEST s 1:SUMP 1 LEAK TEST STARTED Typical Response Message, Computer Format: s099ssYYMMDDHHmmsstt... sstt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time ss - Smart Sensor Number (Decimal, 00=all) tt - Mag Sump Leak Test Status 00=NO TEST DATA AVAILABLE 01=LEAK TEST ABORTED 02=FILL SUMP 03=MEASURING HEIGHT 04=LEAK TEST PASSED && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 34 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 09A Function Type: Start Mag Sump Leak Test Measuring Height Phase Version 26 Command Format: Display: S09Ass149 Computer: s09Ass149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S09Ass FEB 14, 2004 10:15 AM START MAG SUMP LEAK TEST MEASURING HEIGHT PHASE s 1:SUMP 1 STABLILITY PHASE STARTED Typical Response Message, Computer Format: s09AssYYMMDDHHmmsstt... sstt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time ss - Smart Sensor Number (Decimal, 00=all) tt - Mag Sump Leak Test Status 00=NO TEST DATA AVAILABLE 01=LEAK TEST ABORTED 02=FILL SUMP 03=MEASURING HEIGHT 04=LEAK TEST PASSED && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 35 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 09B Function Type: Stop Mag Sump Leak Test Version 26 Command Format: Display: S09Bss149 Computer: s09Bss149 Notes: 1. 149 - This verification code must be sent to confirm the command Typical Response Message, Display Format: S09Bss FEB 14, 2004 10:15 AM STOP MAG SUMP LEAK TEST s 1:SUMP 1 LEAK TEST ABORTED Typical Response Message, Computer Format: s09BssYYMMDDHHmmsstt... sstt&&CCCC Notes: 1. 2. 3. 4. 5. YYMMDDHHmm - Current Date and Time ss - Smart Sensor Number (Decimal, 00=all) tt - Mag Sump Leak Test Status 00=NO TEST DATA AVAILABLE 01=LEAK TEST ABORTED 02=FILL SUMP 03=MEASURING HEIGHT 04=LEAK TEST PASSED && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 36 Serial Interface Manual TLS-300/350/350R Monitoring Systems 7.2 OPERATIONAL REPORTS 7.2.1 SYSTEM REPORTS Function Code: 101 Function Type: System Status Report Version 1 Command Format: Display: I10100 Computer: i10100 Notes: 1. This command will report all active OR unacknowledged alarms and warnings up to the limit of 25 alarms in display format, and 150 alarms in computer format Typical Response Message, Display Format: I10100 JUL 29, 1997 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 9:02 AM 1.... 2.... 3.... 4.... SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL Part No. 576013-635, Revision AA 37 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) Typical Response Message, Computer Format: i10100YYMMDDHHmmAANNTT... AANNTT&&CCCC Notes: 1. 2. YYMMDDHHmm - Current Date and Time AA - Alarm/Warning Category: 00=All Functions Normal 01=System Alarm 02=Tank Alarm 03=Liquid Sensor Alarm 04=Vapor Sensor Alarm 05=Input Alarm 06=Volumetric Line Leak Alarm 07=Groundwater Sensor Alarm 08=Type A Sensor Alarm 12=Type B Sensor Alarm 13=Universal Sensor Alarm 14=Auto-Dial Fax Alarm 18=Mechanical Dispenser Interface Alarm 19=Electronic Dispenser Interface Alarm 20=Product Alarm 21=Pressure Line Leak Alarm 26=Wireless PLLD Alarm 28=Smart Sensor Alarm 29=Modbus Alarm 30=ISD Site Alarm 31=ISD Hose Alarm 32=ISD Vapor Flow Meter Alarm 33=PMC Alarm 34=Pump Relay Monitor Alarm 35=VMCI Dispenser Interface Alarm 36=VMC Alarm 37=APM Alarm (Version 28) (Version 28) (Version 31) 99=Externally Detected Alarm (not reported by Console) Part No. 576013-635, Revision AA 38 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) 3. NN - Alarm Type Number: - If AA is 01 and NN is: 01=Printer out of Paper 02=Printer Error 03=EEPROM Configuration Error 04=Battery Off 05=Too Many Tanks 06=System Security Warning 07=ROM Revision Warning 08=Remote Display Communications Error 09=Autodial Error 10=Software Module Warning 11=Tank Test Shutdown Warning 12=Protective Cover Alarm 13=BIR Shift Close Pending 14=BIR Daily Close Pending 15=PC(H8) Revision Warning 16=System Self Test Error 17=System Clock Incorrect Warning 18=System Device Poll Timeout 19=Maintenance Tracker NVMem Removed 20=Maintenance Tracker Communication Module Removed Part No. 576013-635, Revision AA 39 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) - If AA is 02 and NN is: 01=Tank Setup Data Warning 02=Tank Leak Alarm 03=Tank High Water Alarm 04=Tank Overfill Alarm 05=Tank Low Product Alarm 06=Tank Sudden Loss Alarm 07=Tank High Product Alarm 08=Tank Invalid Fuel Level Alarm 09=Tank Probe Out Alarm 10=Tank High Water Warning 11=Tank Delivery Needed Warning 12=Tank Maximum Product Alarm 13=Tank Gross Leak Test Fail Alarm 14=Tank Periodic Leak Test Fail Alarm 15=Tank Annual Leak Test Fail Alarm 16=Tank Periodic Test Needed Warning 17=Tank Annual Test Needed Warning 18=Tank Periodic Test Needed Alarm 19=Tank Annual Test Needed Alarm 20=Tank Leak Test Active 21=Tank No CSLD Idle Time Warning 22=Tank Siphon Break Active Warning 23=Tank CSLD Rate Increase Warning 24=Tank AccuChart Calibration Warning 25=Tank HRM Reconciliation Warning 26=Tank HRM Reconciliation Alarm 27=Tank Cold Temperature Warning 28=Tank Missing Delivery Ticket Warning 29=Tank/Line Gross Leak Alarm 30=Delivery Density Warning 31=Density Warning 32=Fuel Quality Alarm Part No. 576013-635, Revision AA 40 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) - If AA is 03, 02=Sensor 03=Sensor 04=Sensor 05=Sensor 06=Sensor 07=Sensor 08=Sensor 09=Sensor 10=Sensor - If AA is 05 01=Input 02=Input 03=Input 04, 07, 08, 12, or 13 and NN is: Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm Low Liquid Alarm Liquid Warning and NN is: Setup Data Warning Normal Alarm - If AA is 06 and NN is: 01=VLLD Setup Data Warning 02=VLLD Self Test Alarm 03=VLLD Shutdown Alarm 04=VLLD Leak Test Fail Alarm 05=VLLD Selftest Invalid Warning 06=VLLD Continuous Handle On Warning 07=VLLD Gross Line Test Fail Alarm 08=VLLD Gross Line Selftest Fail Alarm 09=VLLD Gross Pump Test Fail Alarm 10=VLLD Gross Pump Selftest Fail Alarm 11=VLLD Periodic Test Needed Warning 12=VLLD Annual Test Needed Warning 13=VLLD Periodic Test Needed Alarm 14=VLLD Annual Test Needed Alarm 15=VLLD Periodic Line Test Fail Alarm 16=VLLD Periodic Line Selftest Fail Alarm 17=VLLD Periodic Pump Test Fail Alarm 18=VLLD Periodic Pump Selftest Fail Alarm 19=VLLD Annual Line Test Fail Alarm 20=VLLD Annual Line Selftest Fail Alarm 21=VLLD Annual Pump Test Fail Alarm 22=VLLD Annual Pump Selftest Fail Alarm 23=VLLD Pressure Warning 24=VLLD Pressure Alarm 25=VLLD Gross Test Fault Alarm 26=VLLD Periodic Test Fault Alarm 27=VLLD Annual Test Fault Alarm 28=VLLD Fuel Out Alarm - If AA is 14 and NN is: 01=Autodial Setup Data Warning 02=Autodial Failed Alarm 03=Autodial Service Report Warning 04=Autodial Alarm Clear Warning 05=Autodial Delivery Report Warning (Added in V19) (Added in V19) (Added in V19) - If AA is 18, 19 and NN is: 02=DIM Disabled Alarm 03=DIM Communication Failure Alarm 04=DIM Transaction Alarm Part No. 576013-635, Revision AA 41 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) - If AA is 20 and NN is: 01=BIR Setup Data Warning 02=BIR Threshold Alarm 03=BIR Close Shift Warning 04=BIR Close Daily Warning - If AA is 21 and NN is: 01=PLLD Setup Data Warning 02=PLLD Gross Test Fail Alarm 03=PLLD Annual Test Fail Alarm 04=PLLD Periodic Test Needed Warning 05=PLLD Periodic Test Needed Alarm 06=PLLD Sensor Open Alarm 07=PLLD High Pressure Alarm 08=PLLD Shutdown Alarm 09=PLLD High Pressure Warning 10=PLLD Continuous Handle On Warning 11=PLLD Periodic Test Fail Alarm 12=PLLD Annual Test Needed Warning 13=PLLD Annual Test Needed Alarm 14=PLLD Low Pressure Alarm 15=PLLD Sensor Short Alarm 16=PLLD Continuous Handle On Alarm 17=PLLD Fuel Out Alarm 18=PLLD Line Equipment Alarm - If AA is 26 01=WPLLD 02=WPLLD 03=WPLLD 04=WPLLD 05=WPLLD 06=WPLLD 07=WPLLD 08=WPLLD 09=WPLLD 10=WPLLD 11=WPLLD 12=WPLLD 13=WPLLD 14=WPLLD 15=WPLLD 16=WPLLD 17=WPLLD 18=WPLLD Part No. 576013-635, Revision AA and NN is: Setup Data Warning Gross Test Fail Alarm Periodic Test Fail Alarm Periodic Test Needed Warning Periodic Test Needed Alarm Sensor Open Alarm Communications Alarm Shutdown Alarm Continuous Handle On Warning Annual Test Fail Alarm Annual Test Needed Warning Annual Test Needed Alarm High Pressure Warning High Pressure Alarm Sensor Short Alarm Continuous Handle On Alarm Fuel Out Alarm Line Equipment Alarm (Obsolete V19) (Obsolete V19) (Obsolete V19) (Obsolete V19) (Obsolete V19) (Obsolete V19) (Obsolete V19) (Obsolete V19) 42 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) - If AA is 28 01=Smart 02=Smart 03=Smart 04=Smart 05=Smart 06=Smart 07=Smart 08=Smart 09=Smart 10=Smart 11=Smart 12=Smart 13=Smart 14=Smart 15=Smart 16=Smart 17=Smart and NN Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor is: Setup Data Warning Communication Alarm Fault Alarm Fuel Warning Fuel Alarm Water Warning Water Alarm High Liquid Warning High Liquid Alarm Low Liquid Warning Low Liquid Alarm Temperature Warning Relay Active Install Alarm Sensor Fault Warning Vacuum Warning No Vacuum Warning - If AA is 29 and NN is: 01=Improper Setup alarm 02=Communication Loss alarm - If AA is 30 and NN is: 01=Stage 1 Transfer Monitoring Failure warning (ISD only) 02=Containment Monitoring Gross Failure warning (ISD) 03=Containment Monitoring Gross Failure alarm (ISD) 04=Containment Monitoring Degradation Failure warning (ISD only) 05=Containment Monitoring Degradation Failure alarm (ISD only) 06=Containment Monitoring CVLD Failure warning (ISD) 07=Containment Monitoring CVLD Failure alarm (ISD) 08=Vapor Processor Over Pressure Failure warning (ISD only) 09=Vapor Processor Over Pressure Failure alarm (ISD only) 10=Vapor Processor Status Test warning (ISD only) 11=Vapor Processor Status Test alarm (ISD only) 12=Missing Relay Setup alarm (ISD only) 13=Missing Hose Setup alarm (ISD only) 14=Missing Tank Setup alarm (ISD) 15=Missing Vapor Flow Meter alarm (ISD only) 16=Missing Vapor Pressure Sensor alarm (ISD) 17=Missing Vapor Pressure Input alarm (ISD) 18=Setup Fail warning (ISD) 19=Setup Fail alarm (ISD) 20=Sensor Out warning (ISD) 21=Sensor Out alarm (ISD) 22=PC-ISD Offline (ISD) Part No. 576013-635, Revision AA 43 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 101 Notes: (Continued) - If AA is 31 and NN is: 01=Collection Monitoring Gross Failure warning 02=Collection Monitoring Gross Failure alarm 03=Collection Monitoring Degradation Failure warning 04=Collection Monitoring Degradation Failure alarm 05=Flow Performance Hose Blockage Failure warning 06=Flow Performance Hose Blockage Failure alarm 07=Vapor Flow Meter Setup alarm - If AA is 32 and NN is: 01=Locked rotor alarm - If AA is 33 and NN is: 01=Vapor Processor Run Time Fault warning 02=Processor Monitoring Effluent Emissions Failure warning 03=Processor Monitoring Effluent Emissions Failure alarm 04=Processor Monitoring Over Pressure Failure warning 05=Processor Monitoring Over Pressure Failure alarm 06=Processor Monitoring Duty Cycle Failure warning 07=Processor Monitoring Duty Cycle Failure alarm 08=PMC (stand alone mode only) Setup warning - If AA is 34 and NN is: 01=Setup Data Warning 02=Pump Relay Alarm - If AA is 35 and NN is: 01=Setup Data Warning 02=Disabled VMCI Alarm 03=VMC Comm Timeout Alarm - If AA is 36 and NN is: 01=VMC Comm timeout 02=Meter Not Connected 03=FP Shutdown Warning 04=FP Shutdown Alarm (Added in V31) (Obsolete V31) - If AA is 37 and NN is: 01=Gross Over-Pressure Test Warning 02=APM Gross Over-Pressure Test Failure warning 03=APM Gross Over-Pressure Test Failure alarm 04=APM Degradation Over-Pressure Test Failure warning 05=APM Degradation Over-Pressure Test Failure alarm 06=APM Sensor Test Failure warning 07=APM Sensor Test Failure alarm 08=APM Setup Failure warning 09=APM Sensor Out Failure warning 10=APM Sensor Out Failure alarm - If AA is 99 and NN is: 01=Externally Dectected Communication Alarm 02=Communications - Data Reception Timeout 03=Communications - Failed Checksum 04=Communications - Parity Error 05=Modem - Line Busy 06=Modem - No Answer 07=Modem - No Carrier 08=Modem - No Dial Tone 09=Modem - Modem Error 10=Modem - Modem Not Responding 11=Modem - Port Not Available 12=Polling - Could Not Update Queue 13=Polling - Invalid Data Type Requested 4. 5. 6. TT - Tank/Sensor Number && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 44 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 102 Function Type: System Configuration Report Version 1 Command Format: Display: I10200 Computer: i10200 Typical Response Message, Display Format: I10200 JAN 22, 1996 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 3:05 PM 1.... 2.... 3.... 4.... SYSTEM CONFIGURATION SLOT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BOARD TYPE 4 PROBE / G.T. UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED 4 INPUT BOARD UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED COMM 1 FAXMODEM BOARD COMM 2 RS232 SERIAL BD COMM 3 ELEC DISP INT. COMM 4 UNUSED COMM 5 UNUSED COMM 6 UNUSED POWER ON RESET 164040 10191362 10122894 10107912 10115504 10105807 10097749 10102487 40158 15000000 15000000 15000000 15000000 15000000 15000000 15000000 47008 14764 100725 15000000 15000000 15000000 CURRENT 166912 10329900 10209602 10186864 10165331 10165451 10164467 10152837 40158 15000000 15000000 15000000 15000000 15000000 15000000 15000000 47006 14753 100748 15000000 15000000 15000000 Part No. 576013-635, Revision AA 45 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 102 Notes: (Continued) Typical Response Message, Computer Format: i10200YYMMDDHHmmNNSSTTFFFFFFFFCCCCCCCC... SSTTFFFFFFFFCCCCCCCC&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. 8. YYMMDDHHmm - Current Date and Time NN - Number of Modules to Follow (Hex) SS - Slot Number (Hex) TT - Type of Module (Hex): 00=Not used 01=Four Probe Module 02=Vapor Sensor Module 03=Liquid Sensor Module 04=Four Relay Module 05=I/O Combo Module 06=Printer Module 07=RS-232 Module 08=Modem Module 09=Volumetric Line Leak Module 0A=Four Probe w/ Ground Temp Module 0B=Groundwater Sensor Module 0C=Type A Sensor Module 0D=Remote Display Module 10=Type B Sensor Module 11=Universal Sensor Module 12=Fax/Modem (1785) Module 13=Remote/Local Printer Module 14=Pump Sensor Module 15=European RS-232 Module 17=Eight Probe Module 18=Mechanical Dispenser Interface Module 19=Electronic Dispenser Interface Module 1A=Pressure Line Leak Sensor Module 1B=Pressure Line Leak Controller Module 1D=Remote Printer Module 1E=External Fax/Modem Module 1F=RS-485 Module 20=Wireless PLLD AC Interface Module 21=Wireless PLLD Communications Module 22=Wireless PLLD Controller Module 23=Hughes Satellite J-Box Module 24=Fax/Modem (1786) Module 25=Serial Satellite Module 26=Four Probe / Four Liquid Sensor Module 27=Four PLLD Sensor Module 28=SmartSensor(8) Module 29=RS-485 Modbus Module 2B=SmartSensor(7) Module 2C=Four Input Module 2D=MT Comm Module 2E=Pump Relay Monitor Module 2F=VMCI Dispenser Interface Module FFFFFFFF CCCCCCCC && CCCC - (Version (Version (Version (Version 26) 27) 27) 28) Power On Reset (ASCII Hex IEEE float) Current I/O Reading (ASCII Hex IEEE float) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 46 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 111 Function Type: Priority Alarm History Report Version 2 Command Format: Display: I11100 Computer: i11100 Typical Response Message, Display Format: I11100 JUL 29, 1997 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 9:02 AM 1.... 2.... 3.... 4.... PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION W 3 OTHER SPECIAL W 3 OTHER SPECIAL SYSTEM SYSTEM ALARM TYPE WPLLD SHUTDOWN ALM WPLLD SHUTDOWN ALM BATTERY IS OFF BATTERY IS OFF STATE CLEAR ALARM CLEAR ALARM DATE 1-01-96 1-01-96 1-01-96 1-01-96 TIME 8:07AM 8:06AM 8:00AM 8:00AM Typical Response Message, Computer Format: i11100YYMMDDHHmmAAccNNTTSSYYMMDDHHmm... AAccNNTTSSYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. YYMMDDHHmm - Current Date and Time AA - Alarm/Warning Category: See explanation for "AA" in Function i10100 cc - Sensor Category 00=Other 01=Annular 02=Dispenser Pan 03=Monitoring Well 04=STP Sump 05=Piping Sump NN - Alarm Type Number: See explanation for "NN" in Function i10100 TT - Tank/Sensor Number SS - Alarm State 01=Alarm cleared 02=Alarm occurred YYMMDDHHmm - Date/Time Alarm state occurred && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 47 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 112 Function Type: Non-Priority Alarm History Report Version 2 Command Format: Display: I11200 Computer: i11200 Typical Response Message, Display Format: I11200 JAN 22, 1996 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 3:05 PM 1.... 2.... 3.... 4.... NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION SYSTEM SYSTEM T 2 TANK SPECIAL T 2 TANK SPECIAL ALARM TYPE PAPER OUT PAPER OUT INVALID FUEL LEVEL INVALID FUEL LEVEL STATE CLEAR ALARM CLEAR ALARM DATE 12-20-95 12-20-95 12-20-95 12-20-95 TIME 12:01PM 12:00PM 11:59AM 11:59AM Typical Response Message, Computer Format: i11200YYMMDDHHmmAAccNNTTSSYYMMDDHHmm... AAccNNTTSSYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. YYMMDDHHmm - Current Date and Time AA - Alarm/Warning Category: See explanation for "AA" in Function i10100 cc - Sensor Category 00=Other 01=Annular 02=Dispenser Pan 03=Monitoring Well 04=STP Sump 05=Piping Sump NN - Alarm Type Number: See explanation for "NN" in Function i10100 TT - Tank/Sensor Number SS - Alarm State 01=Alarm cleared 02=Alarm occurred YYMMDDHHmm - Date/Time Alarm state occurred && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 48 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 113 Function Type: Active Alarm Report Version 14 Command Format: Display: I11300 Computer: i11300 Notes: 1. This command will report ALL active alarms and warnings regardless of their acknowledgement state. If there are more than can be contained in the non-priority and priority history storage areas, they will be reported here without time and date stamps Typical Response Message, Display Format: I11300 JAN 28, 1996 10:09 AM STATION STATION STATION STATION HEADER HEADER HEADER HEADER 1.... 2.... 3.... 4.... ACTIVE ALARMS REPORT ID CATEGORY SYSTEM T 2 TANK DESCRIPTION SPECIAL ALARM TYPE PAPER OUT INVALID FUEL LEVEL DATE TIME 12-20-95 12:00PM 12-20-95 11:59AM Typical Response Message, Computer Format: i11300YYMMDDHHmma..ab..bc..cd..dAAccNNTTYYMMDDHHmm... AAccNNTTYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm a..a b..b c..c d..d AA - 7. cc - 8. NN - 9. 10. 11. 12. TT YYMMDDHHmm && CCCC - Current Date and Time Station Header 1: 20 ASCII characters Station Header 2: 20 ASCII characters Station Header 3: 20 ASCII characters Station Header 4: 20 ASCII characters Alarm/Warning Category: See explanation for "AA" in Function i10100 Sensor Category 00=Other 01=Annular 02=Dispenser Pan 03=Monitoring Well 04=STP Sump 05=Piping Sump Alarm Type Number: See explanation for "NN" in Function i10100 Tank/Sensor Number Alarm Date and Time Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 49 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 114 Function Type: Cleared Alarm Report Version 19 Command Format: Display: I11400 Computer: i11400 Typical Response Message, Display Format: I11400 JAN 28, 1996 10:09 AM STATION STATION STATION STATION HEADER HEADER HEADER HEADER 1.... 2.... 3.... 4.... CLEARED ALARMS REPORT ID CATEGORY T 4 TANK T 1 TANK SYSTEM DESCRIPTION PRODUCT 4 PRODUCT 1 ALARM TYPE PROBE OUT INVALID FUEL LEVEL PAPER OUT STATE CLEAR CLEAR CLEAR DATE TIME 1-02-96 4:10AM 1-02-96 1:12AM 1-02-96 1:09AM Typical Response Message, Computer Format: i11400YYMMDDHHmma..ab..bc..cd..dAAccNNTTSSYYMMDDHHmm... AAccNNTTSSYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm a..a b..b c..c d..d AA - 7. cc - 8. NN - 9. 10. TT SS - 11. 12. 13. YYMMDDHHmm && CCCC - Current Date and Time Station Header 1: 20 ASCII characters Station Header 2: 20 ASCII characters Station Header 3: 20 ASCII characters Station Header 4: 20 ASCII characters Alarm/Warning Category: See explanation for "AA" in Function i10100 Sensor Category 00=Other 01=Annular 02=Dispenser Pan 03=Monitoring Well 04=STP Sump 05=Piping Sump Alarm Type Number: See explanation for "NN" in Function i10100 Tank/Sensor Number Alarm State 01=Alarm cleared 02=Alarm occurred Clear Alarm Date and Time Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 50 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 115 Function Type: Maintenance Tracker Unacknowledged Alarm Report Version 27 Command Format: Display: I11500 Computer: i11500 Typical Response Message, Display Format: I11500 JUL 29, 2006 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 3:05 PM 1.... 2.... 3.... 4.... MAINTENANCE TRACKER UNACKNOWLEDGED ALARM REPORT ID CATEGORY L12 OTHER L 1 OTHER DESCRIPTION LIQUID SENS 12 LIQUID SENS 1 ALARM TYPE SENSOR OUT SENSOR OUT DATE 7-08-06 7-08-06 TIME 11:12AM 10:10AM Typical Response Message, Computer Format: i11500YYMMDDHHmma..ab..bc..cd..dAAccNNTTYYMMDDHHmm... AaccNNTTYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm a..a b..b c..c d..d AA - 7. cc - 8. NN - 9. 10. 11. 12. TT YYMMDDHHmm && CCCC - Current Date and Time Station Header 1: 20 ASCII characters Station Header 2: 20 ASCII characters Station Header 3: 20 ASCII characters Station Header 4: 20 ASCII characters Alarm/Warning Category: See explanation for "AA" in Function i10100 Sensor Category 00=Other 01=Annular 02=Dispenser Pan 03=Monitoring Well 04=STP Sump 05=Piping Sump Alarm Type Number: See explanation for "NN" in Function i10100 Tank/Sensor Number Maintenance Tracker Alarm Active Date and Time Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 51 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 116 Function Type: Service Report History Version 19 (Obsolete V27) Command Format: Display: I11600 Computer: i11600 Typical Response Message, Display Format: I11600 MAR 26, 1996 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 1:47 PM 1.... 2.... 3.... 4.... SERVICE REPORT DATE/TIME MAR 29, 1996 MAR 28, 1996 FEB 26, 1996 JAN 25, 1996 JAN 23, 1996 8:50 8:50 8:15 2:20 1:48 AM AM AM PM PM ID 1234567890 3482221100 3482221100 3482221100 3482221100 CODE 12345 EABC2 12345 Z1234 12345 Typical Response Message, Computer Format: i11600YYMMDDHHmma..ab..bc..cd..dNNYYMMDDHHmmiiiiiiiiiiccccc... YYMMDDHHmmiiiiiiiiiiccccc&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. YYMMDDHHmm a..a b..b c..c d..d NN YYMMDDHHmm iiiiiiiiii ccccc && CCCC - Current Date and Time Station Header 1: 20 ASCII characters Station Header 2: 20 ASCII characters Station Header 3: 20 ASCII characters Station Header 4: 20 ASCII characters Number of Records to follow (Decimal) Date and Time of entry Service ID entered by Service Contractor (10 alpha/numeric) Service Code entered by Service Contractor (5 alpha/numeric) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 52 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 119 Function Type: Maintenance History Report Version 27 Command Format: Display: I11900YYMMDDYYMMDD OR I11900 Computer: i11900YYMMDDYYMMDD OR i11900 Notes: 1. 2. 3. YYMMDD - Requested Start Date (year, month, day). YYMMDD - Requested End Date (year, month, day). - If the dates are not specified, the most recent 20 records are returned. Typical Response Message, Display Format: I11900 MAR 26, 2006 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 1:47 PM 1.... 2.... 3.... 4.... MAINTENANCE HISTORY TYPE LOGOUT SERVICE CODE SERVICE CODE ALARM ACKNOWLEDGED ALARM ACKNOWLEDGED LOGIN ALARM CLEAR ALARM CLEAR ALARM ACTIVE ALARM ACTIVE MTC ERR ALARM CLEAR ALARM ACTIVE HISTORY DISABLED VLLD TEST WPLLD TEST PLLD TEST TANK TEST HISTORY ENABLED DATE/TIME JAN 09, 2006 11:50 AM JAN 09, 2006 10:27 AM JAN 09, 2006 9:55 AM JAN 09, 2006 8:52 AM JAN 09, 2006 8:52 AM JAN 09, 2006 8:50 AM JAN 08, 2006 7:31 AM JAN 08, 2006 7:30 AM JAN 08, 2006 6:52 AM JAN 08, 2006 6:50 AM JAN 05, 2006 8:30 PM JAN 03, 2006 8:30 AM JAN 03, 2006 6:25 AM JAN 02, 2006 7:25 PM JAN 02, 2006 6:25 PM JAN 02, 2006 3:45 PM JAN 02, 2006 1:45 PM JAN 02, 2006 10:28 AM JAN 01, 2006 6:25 AM Part No. 576013-635, Revision AA DESCRIPTION J SMITH A12345 COLD BOOT SYSTEM 1203 INSTALLED PAPER 1211 L12:SENSOR OUT ALARM L 1:SENSOR OUT ALARM J SMITH A12345 L12:SENSOR OUT ALARM L 1:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SENSOR OUT ALARM L 1:SENSOR OUT ALARM L 1:SENSOR OUT ALARM P W Q T 1 1 1 1 0.2 GPH TEST PASS 0.2 GPH TEST PASS 0.2 GPH TEST PASS PERIODIC TEST PASS 53 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code 119 Notes: (Continued) Typical Response Message, Computer Format: i11900YYMMDDHHmmNNNNNYYMMDDHHmmttXXXXXXYYMMDDHHmmttXXXXXX... YYMMDDHHmmttXXXXXX&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. YYMMDDHHmm NNNNN YYMMDDHHmm tt - Current Date and Time Number of records to Follow (Decimal) Date/time of record Record type (Hex) 01=Maintenance History Enabled 02=Maintenance History Disabled 03=Maintenance Tracker Login 04=Maintenance Tracker Logout 05=Maintenance Tracker Remote Login 06=Maintenance Tracker Remote Logout 07=Maintenance Alarm Active 08=Maintenance Alarm Inactive 09=Maintenance Alarm Acknowledge 0A=Maintenance Alarm Remote Acknowledge 0B=Service Code 0C=Tank Test, 0.20 Gal/Hr Fullest Monthly 0D=PLLD Test, 0.20 Gal/Hr Latest Monthly 0E=WPLLD Test, 0.20 Gal/Hr Latest Monthly 0F=MT Comm Card Removed 10=VLLD Test, 0.20 Gal/Hr Latest Monthly XXXXXX - Six digit data field: 000000= place filler (unused) for types 01, 02 iiiiii= login ID code for types 03, 04, 05, 06 (ASCII, padded with leading zeros) ddttnn= Alarm device #, type, and alarm number for types 07, 08, 09, 0A (Decimal) 00cccc= Four digit service code for type 0B (Decimal, padded with leading zeros) 0000tt= Device # for types 0C, 0D, 0E (Decimal, padded with leading zeros) 000000= Place filler (unused) for type 0F && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 54 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 11A Function Type: Service Report History Version 27 Command Format: Display: I11A00 Computer: i11A00 Typical Response Message, Display Format: I11A00 MAR 26, 2006 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 1:47 PM 1.... 2.... 3.... 4.... SERVICE REPORT DATE/TIME MAR 29, 2006 MAR 28, 2006 FEB 26, 2006 JAN 25, 2006 JAN 23, 2006 8:50 8:50 8:15 2:20 1:48 AM AM AM PM PM LABEL J DOE D SMITH D SMITH D SMITH D SMITH ID A12345 A34822 A34822 A34822 A34822 LABEL INSTALLED PAPER CLEARED PAPER JAM RECONNECT PHONE LN REPLACED PROBE FIX STUCK FLOAT CODE 1211 0204 0503 0304 0305 Typical Response Message, Computer Format: i11A00YYMMDDHHmmNNYYMMDDHHmmiiiiiicccc... YYMMDDHHmmiiiiiicccc&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. YYMMDDHHmm NN YYMMDDHHmm iiiiii cccc && CCCC - Current Date and Time Number of Records to follow (Decimal) Date and Time of entry Service ID entered by Service Contractor (6 alpha/numeric) Service Code entered by Service Contractor (4 numeric) Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 55 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 11B Function Type: Service Notice Session Report Version 28 Command Format: Display: I11B00 Computer: i11B00 Typical Response Message, Display Format: I11B00 APR 10, 2007 STATION STATION STATION STATION HEADER HEADER HEADER HEADER 3:05 PM 1.... 2.... 3.... 4.... SERVICE NOTICE SESSION REPORT START TIME APR 10, 2007 APR 9, 2007 APR 8, 2007 8:00 AM 8:10 AM 8:05 AM END TIME IN PROGRESS APR 9, 2007 APR 8, 2007 9:10 AM 8:45 AM Typical Response Message, Computer Format: i11B00YYMMDDHHmmfYYMMDDHHmmNNYYMMDDHHmmYYMMDDHHmm... YYMMDDHHmmYYMMDDHHmm&&CCCC Notes: 1. 2. 3. 4. 5. 6. 7. 8. YYMMDDHHmm - Current Date and Time f - Service Notice Session Enable 0 = Disabled 1 = Enabled YYMMDDHHmm - Start Date and Time - if Service Notice Session Enable = 0 (Disabled) then Start Date/Time is invalid - if Service Notice Session Enable = 1 (Enabled) then Start Date/Time is valid NN - Number of Service Notice Session Start/End records to follow (Hex) YYMMDDHHmm - Start Date and Time YYMMDDHHmm - End Date and Time && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 56 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 132 Function Type: Fiscal Height Security Report Version 32 Command Format: Display: I13200 Computer: i13200 Typical Response Message, Display Format: I13200 APR 1, 2011 8:03 AM FISCALLY SEALED : NO FISCAL HEIGHT SECURITY : DISABLED FISCAL HEIGHT SECURITY SWITCH : OFF Typical Response Message, Computer Format: i13200YYMMDDHHmmsfp&&CCCC Notes: 1. 2. 3. 4. 5. 6. YYMMDDHHmm - Current Date and Time s - Is Fiscally Sealed 0=No 1=Yes f - Fiscal Height Security Enable/Disable Flag 0=Disabled 1=Enabled p - Fiscal Height Security Switch Position 0=Off 1=On && - Data Termination Flag CCCC - Message Checksum Part No. 576013-635, Revision AA 57 Serial Interface Manual TLS-300/350/350R Monitoring Systems 7.2.2 IN-TANK REPORTS Function Code: 201 Function Type: In-Tank Inventory Report Version 1 Command Format: Display: I201TT Computer: i201TT Typical Response Message, Display Format: I201TT JAN 22, 1996 STATION STATION STATION STATION 3:06 PM HEADER HEADER HEADER HEADER 1.... 2.... 3.... 4.... TANK PRODUCT 1 REGULAR UNLEADED VOLUME TC VOLUME 5329 5413 ULLAGE 4699 HEIGHT 48.97 WATER 0.00 TEMP 37.39 Typical Response Message, Computer Format: i201TTYYMMDDHHmmTTpssssNNFFFFFFFF... TTpssssNNFFFFFFFF&&CCCC Notes: 1. 2. 3. 4. YYMMDDHHmm TT p ssss - 5. 6. NN FFFFFFFF - 7. 8. && CCCC - Current Date and Time Tank Number (Decimal, 00=all) Product Code (one ASCII character [20h-7Eh]) Tank Status Bits: Bit 1 - (LSB) Delivery in Progress Bit 2 - Leak Test in Progress Bit 3 - Invalid Fuel Height Alarm (MAG Probes Only) Bit 4-16 - Unused Number of eight character Data Fields to follow (Hex) ASCII Hex IEEE floats: 1. Volume 2. TC Volume 3. Ullage 4. Height 5. Water 6. Temperature 7. Water Volume Data Termination Flag Message Checksum Part No. 576013-635, Revision AA 58 Serial Interface Manual TLS-300/350/350R Monitoring Systems Function Code: 202 Function Type: In-Tank Delivery Report Version 1 Command Format: Display: