PETRO METER TCS 3000 Register Operations Manual
User Manual: manual pdf -FilePursuit
Open the PDF directly: View PDF .
Page Count: 41
Download | |
Open PDF In Browser | View PDF |
Catalog Title TCS 3000 REGISTER Catalog Subtitle Setup & Operation Manual Table of Contents Table of Contents Receipt & Inspection Notice Introduction System Specifications TCS 3000 Start Up Navigation Navigation (Continued) Display Icons Select Functions Start Delivery Show Last Delivery Begin or End Shift Duplicate Shift Ticket Re-Print Tickets System Menu Reports Show Prover Status Prover Ticket Meter Info Version Info Memory Status Display Settings Display Settings Printer Settings Enable / Disable Printer Select Printer Enable / Disable Host Clients Address Range Regional Settings Delivery Settings Configure Ticket Configure Ticket (Continued) Accounting Presets Multiple Deliveries Customer ID Display Precision Zero-Flow Timeout Auxiliary Devices External Display External Display (Continued) Air Elimination Additive Injection Pulse Output Connectivity Misc. Settings 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 9 10 10 10 10 10 10 10 11 11 12 12 12 12 12 12 12 13 14 14 14 14 14 15 15 15 15 15 15 16 16 16 W&M Settings Products Product Test Run Recalibrate Product Modify Parameters Product Name Comp. Table Comp. Table Param. Mass Density Pump Control Valve Type Maximum Flow Pulser Type Pulse Estimate Product Units Product Units (Cont.) Hose Volume Begin Recalibration Edit Calibration Add New Product Remove Product System Metrics Temp Probe Meter Information Prover Ticket Reset Totalizers Enable Remote Config Product Settings Product Prices Product Prices (Continued) Activate Product Deactivate Product Preset Timing Preset Timing Air Eliminator Hold Hose Volume Product Lists Advanced Functions System Shutdown System Update Start Up “Must Knows” Inventory How To Daisy Chain Daisy Chain (Continued) Temperature Probe Calibration Trouble Shooting Trouble Shooting (Continued) Trouble Shooting (Continued) Trouble Shooting (Continued) Notes Notes Warranty 2 17 17 17 17 18 18 18 18 19 19 19 20 20 20 20 20 20 21 21 21 22 22 22 22 23 23 23 24 24 24 26 26 26 26 26 26 26 27 27 27 28 29 30 31 32 33 34 35 36 37 37 39 Receipt & Inspection Upon receipt of register shipment, be sure to inspect the packaging and the register assembly for any damage before signing the receipt of the shipment. Notify the delivery company about possible damage and refuse receipt of the shipment. Registers are individually boxed and are protected with static resistant packing material. Each package is identified with the register assembly part number, description, serial number. Verify the register model is the correct model, size, and configuration as ordered. Contact your distributor if there is any discrepancy or question. Register assemblies should be handled with appropriate methods for the size and weight involved. Appropriate clothing and shoes need to be utilized. Transport the register package to the installation site with appropriate transportation methods, careful not to damage the register. Be careful of any loose or protruding staples from the packaging, as they can be very sharp and may potentially cause injury. If foam has been used to protect register, carefully remove top foam layer before attempting to remove register assembly from box. Foam packaging maybe formed around the register assembly making it difficult to remove. Do not lift the register assembly by wires or anything other than the metal body of the register. Do not insert objects or cables into the register unless stated. Removing register assembly from packaging without adhering these warnings may cause serious injury to you and/or the register. Appropriate precautions should be taken regarding any personal, environmental and material compatibility with the end use system. Notice Total Control Systems (TCS) shall not be liable for technical or editorial errors in this manual or omissions from this manual. TCS makes no warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose with respect to this manual and, in no event, shall TCS be liable for special or consequential damages including, but not limited to, loss of production, loss of profits, etc. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time. TCS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any TCS product remains solely with the purchaser and end-user. All rights reserved. No part of this work may be reproduced or copied in any form or by any means – graphic, electronic or mechanical – without first receiving the written permission of Total Control Systems, Fort Wayne, Indiana USA. 3 Introduction The TCS 3000 register is a fully integrated custody transfer flow computer that will control all vehicle delivery operations. The Open Software Architecture provides the option of a simple “Pump & Print” delivery or a custom measurement solution. The TCS 3000 features a 4.5”x 3.5” full color VGA display screen, multiple delivery screens and a flexible mounting with backlit alpha-numeric keypad for the user interface. Available in flexible mounting configurations of 75 or 90 degree displays for meter mounting, and a remote mounting. As an flow computer with open software architecture, there will always be a need to add features to the register as the industry applications evolve. Therefore please be reminded to contact the factory for periodic updates. The TCS 3000 electronic register is a fully integrated flow computer that will control all delivery operations. The modular design and open software architecture provide you with a tailored system that is expandable for future needs. The TCS 3000 features a large easy view VGA screen, alpha-numeric keypad and open printer interface for simple “Pump and Print” deliveries. Software features offer complete flexibility of delivery screen information and view, preset, price/tax, ticket format and password protection. Optional GPS, Bluetooth, Wi-Fi and Cellular capability enables the TCS 3000 to improve your product security and ease access to your delivery data to reduce your operation costs. Many additional features are available (multiple product delivery, additive injection, density/temperature correction, multiple valve & pump control, etc.) to enhance your measurement solution. TCS 3000 - This manual will help guide you with the setup confirmation and calibration of the register. Additional information will be provided for wiring instruction and auxiliary devices to integrate into the register. System Specifications ELECTRICAL Power: 12—24V, 4A DC INPUT A fuse shall be provided in the field to limit the 12VDC power source to 4 amps max. Current: Solid State Relays: 1.4 Amp 12/24 Vdc; Passive Solid State INTERNAL PULSER Pulse Ratio Power Hertz 400:1 PPR; Quadrature 5 Vdc 0 — 5000 Hz EXTERNAL PULSE INPUT Type Power Single or Dual Channel (Quadrature) 5 Vdc ENCLOSURE Aluminum die cast with epoxy powder coat Built to Ingress Protection 66 and Nema 4 ratings Temperature Range: -40 F to 158 F (-40 C to 70 C) Ports: Ten 1/2” NPT UL, cUL threaded connection ports, ATEX Backlit LED Keypad Calibration optical switch, password and mechanical seal UL/cUL Rating Class 1, Division 2, Group C + D The USB0 and USB1 connectors are for maintenance only. To access these connectors, power to the unit is to be Disconnected or the area known to be free of ignitable gas or equivalent. COMMUNICATION Four RS 485 output, 2-wire half duplex, custom protocol; 9600 baud, 8 bit, no parity, 1 stop bit One RS 232 output, 9600 baud; 8 bit, no parity, 1 stop bit 4 WARNINGS: SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS C AND D HAZARDOUS LOCATIONS, OR UNCLASSIFIED LOCATIONS. WARNING– EXPLOSION HAZARD– DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS WARNING– EXPLOSION HAZARD– SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. TCS 3000 Register Start Up: Before placing this register into service you will receive a warning when you turn on the register to calibrate the device before using. It will read as follows: Caution Before Placing this product into service, make sure that the register has been properly calibrated and setup for the type of fluid being measured. This includes calibration factor, compensation type, compensation parameter, product type, valve settings, no flow timeout and others. Refer to the operation manual supplied with the register for instructions. Failure to properly calibrate and setup the register can result in unexpected operation, inaccurate measurements and damage to equipment or property. Navigation Keyboard Functions Start/Enter Key Power Light Stop/Cancel Key Arrow Keys Power Light Allows you to see that there is power to the electronic register. Start/Enter Key Allows you to enter register functions and start deliveries. Stop/Cancel Key Allows you to stop a delivery and cancel an operation. Arrow Keys Allow you to move to different fields on the Register. 5 Navigation Keyboard Functions (Continued) Alpha, Numeric, and Symbol Keys Preset Key Print Key Mode Key Shift Key Preset Key Alpha/Numeric Keys Mode Key Print Key Shift Key Shift & Mode Allows you to PRESET the Price and Tax as well as Gallons into the Register. Allow you to enter different prices, products, etc. into the Register. MODE allows you to select different screens on the Register. Allows you to print. You can print the delivery with or without selecting the STOP key. Allows you to select the Alpha Keys on the Alpha/Numeric Keys. Selecting Shift allows you to use anything on the Key Pad in yellow. Allows you to get into the main Menu screen. Display Icons ICON DESCRIPTION Printer with no ticket. No printer connection Printer ready with Ticket Valve not open Valve(s) open System Settings Weights & Measures AIR Air/Vapor Exhaust 6 Select Function SELECT FUNCTION MENU (Quick Guide) Start Delivery Show Last Delivery Begin or End Shift Duplicate Shift Ticket Re-Print Tickets Non-Printed Delivery Already Printed Delivery Shift Tickets System Menu Reports System Settings W&M Settings Product Settings Advanced Functions Begins delivery transaction. Shows the last delivery on the TCS 3000 screen. Beginning Shift will take a record of Delivery information at the start through the end of the user shift. Duplicate Shift Ticket will print a duplicate of the Begin or End Shift. Will reprint past delivery transactions Prints the last 75 transactions that have not printed. Reprints the last ### of transactions already printed Reprints the last ### of shift tickets. Setup and Configuration MENU’S for TCS 3000 Calibration Log / Identification and Software Version Configuration of System Parameters, Printer and Auxiliary Devices Product Setup and Calibration Product Activation, Price Settings and Device Time Settings System Software Update SELECT FUNCTION — Start Delivery 1) START DELIVERY. Press START to begin delivery transaction. This will reset the register causing the delivery screen to read 0.0. Start your delivery. 2) If a Preset or Customer ID Field is Enabled, the delivery process will begin with prompts requesting data input. See Page 14 for Preset Settings and / or for Customer ID Field to Enable/Disable. 3) If a Multiple Tank Delivery is Enabled, the Operating Driver must Hold the Shift Key down while pressing the START key. When the Multiple Tank Delivery begins, a multiple tank icon will be displayed during delivery. See Page14 for Multiple Tank Delivery to Enable/Disable. 4) Finish the delivery. Press STOP once to PAUSE and twice to STOP. If the Printer is Enabled, the ticket will be printed automatically. If the printer is not Enabled, it will be stored in memory to be retrieved at a later date. 7 Select Function —Show Last SHOW LAST Press START/ENTER to see the last delivery transaction —Begin Shift/End Shift The Shift function records the Time/Date, Meter Identification and the Delivery Data from the beginning of the shift to the end of the shift. NOTE: This function is only accurate as the driver operators that utilize this feature. 1) BEGIN SHIFT Press and hold the SHIFT key, then press the MODE key. 2) END SHIFT Press and hold the SHIFT key, then press the MODE key. 3) After or before each Shift, the display will read Saving and Printing BEGIN or END Shift Ticket. Sample Begin and End Shift Tickets View Inventory View Inventory allows you to select and view the inventory of product in the tank. INVENTORY DISPLAY Displays the inventory and tank size. 8 Select Function SELECT INVENTORY Allows you to use the arrow keys to select the product in order to view the Inventory Details. PRINT INVENTORY REPORT Generates a ticket of the Inventory Report —Duplicate Shift Ticket To print a Duplicate Shift Ticket, navigate down to select the function and press ENTER. —Re-Print Tickets To locate and reprint a past delivery ticket, navigate down to select the function and press ENTER 1) NON PRINTED DELIVERY Will ask how many of the last sequential tickets (that have NOT printed) do you wish to print. Enter quantity and press ENTER. 2) ALREADY PRINTED DELIVERY Will ask how many of the last sequential tickets do you wish to re-print. Enter quantity and press ENTER. 3) SHIFT TICKETS Will ask how many of the last sequential tickets do you wish to re-print. Enter quantity and press ENTER. System Menu (Quick Guide) Report Show Prover Status Prover Ticket Meter Info Version Info View and print calibration, meter information and software Weights & Measures access, calibration and configuration log Print calibration proving ticket Meter identification Operating Firmware and Software System Settings Display Settings Printer Settings Regional Settings Delivery Settings Auxiliary Devices Connectivity Misc. Settings Configuration of system functions Configure display screens and fields Select printer, host ,remote or none Date and Time settings Configure delivery functions like tickets, presets, ID fields, etc. Select and configure auxiliary devices and pulse output Configure register and printer addresses for network data sharing Password settings W&M Settings Products System Metrics Temp Probe Meter Information Prover Ticket Reset Totalizers Enable Remote Config Weights & Measures product setup and calibration Product settings and calibration Unit of measure precision Temperature probe calibration Register, Meter and Truck Identification Print calibration proving ticket Reset system and product totalizers Remote interface configuration Product Settings Product Prices Activate Product Deactivate Product Product Timing Product Lists Product identification for shifts and price/tax Product pricing and taxation Activating onboard products within Shifts Deactivating onboard products outside of Shifts Product preset and auxiliary device timing Listing of active, inactive and uncalibrated products Advanced Functions System Shutdown System Update Administrative Configuration Rebooting of system Software update 9 System Menu —Reports 1) SHOW PROVER STATUS Selecting Show Prover Status allows you to view the last date and time of the last calibration. 2) PROVER TICKET Selecting Prover Ticket allows you to print the prover information from the register. 3) METER INFO Selecting Meter Information allows you to view the Meter Data, such as The Truck ID, Register ID, Meter Make, Meter Model, Meter Version, and the Meter Serial Number. Information must be input within the Weights & Measures menu. 4) VERSION INFO Selecting Version Info allows you to view the Version of Software and Firmware running on the TCS 3000. 5) MEMORY STATUS Selecting Memory Status allows you to view the number and type of tickets printed by the TCS3000. —System Settings 1) DISPLAY SETTINGS DELIVERY SCREENS Select Active Type Configure Type 1 Configure Type 2 Configure Type 3 Active Type allows you to set your DEFAULT display screen. Highlight the type (type 1, 2, or 3) of screen you would like to view during delivery and start-up. Using the arrow keys to move around the screen, highlight the field you would like to change and select ENTER. The field options are in Table 1 below. Using the arrow keys to move around the screen, highlight the field you would like to change and select ENTER. The field options are in Table 1 below. Using the arrow keys to move around the screen, highlight the field you would like to change and select ENTER. The field options are in Table 1 below. Empty No Data Product Name (LPG, Diesel, Av Gas, Etc.) Delivery Gross Non-Compensated Delivery Total Delivery Net Compensated Delivery Total Delivery Volume Amount of Delivery Delivery Total Total Delivered Flowrate Amount Delivered through Per Minute AVG Temperature Average Temperature of Product Temperature Temperature of Product Mass Mass of the Product (e.g. Pounds per Gallon, etc.) Preset Remain Remaining Preset (What is left of the Preset Total) Preset Volume Preset Volume Amount for Delivery Preset Amount Preset Currency Amount for Delivery Density Density of the Product TABLE 1 10 System Menu TYPE 1 TYPE 2 TYPE 3 TYPE 4 * TYPE 4 Only displays delivered volume. CALIBRATION SCREEN Temperature Flowrate Empty Calibration screen will show volume/mass and Temperature Calibration screen will show volume/mass and Flowrate Calibration screen will show volume/mass and nothing else BRIGHTNESS Brightness allows you to set the brightness of the display screen from 100 to 30 percent (brightest to dimmest) settings. NET TOTALIZER Net Totalizer allows you to set whether the Net Totalizer is visible on the display screen. Always Auto Net Totalizer is always visible Net Totalizer is visible only when a product has Automatic Temperature Correction (ATC) enabled on a Product net Totalizer is never visible Never GROSS TOTALIZER Gross Totalizer allows you to set whether the Gross or Volume Totalizer is visible on the display screen. Volume Totalizer Mass Totalizer Volume Totalizer is always visible Mass Totalizer is always visible 2) PRINTER SETTINGS ENABLE/DISABLE PRINTER Enable Disable Allows the printer to operate. Highlight Enable and select ENTER. When the printer is Enabled, a printer icon will appear in the top left portion of the screen. Will not allow the printer to operate. Highlight Disable and select ENTER. When the printer is Disabled, the little printer will disappear in the top left portion of the screen. 11 Weights & Measures SELECT PRINTER Epson TMU 220/295 Citizen CMP30 Printek Blaster Remote None Epson slip or roll printer driver installed Citizen printer driver installed Printek printer driver installed Blaster printer driver installed Selecting Remote will allow you to use a printer remotely when connected to the register through a daisy chain RS485 serial communication. Selecting None will remove the communication for printing PRINTER HOST Printer Host is used when you plan to daisy chain multiple TCS 3000 registers together for a single printer. Host is the primary meter and the Clients are all registers following the Host. Enable/Disable Host To Enable or Disable the Printer Host, highlight Enable or Disable and select ENTER - Enable will allow you to use Printer Host - Disable will not allow you to use Printer Host 3) REGIONAL SETTINGS DATE & TIME Date Format MMMM DD, yyyy MM/dd/yyyy yy/MM/dd dd/mm/yyyy dd/mm/yy Time Format 24 Hour Clock 12 Hour Clock AM/PM Set Date Year — Format YYYY Month — Select Month Date — Select Date Set Time Format time as Hours (input from 24 hr. clock) . Minutes . Seconds (HH.MM.SS) NOTE: a period must be used as your divider DECIMAL SYMBOL Select a ‘.’ period or a ‘,’ comma and press ENTER 4) DELIVERY SETTINGS CONFIGURE TICKETS Select Ticket Type Sets the DEFAULT for the delivery ticket. Choose from the following: CUSTOM1 Allows you to customize the ticket MAXIMUM Allows the maximum amount of space on the ticket. MINIMUM Allows the minimum amount of space to be used on the ticket. ONELINER CUSTOMIZE TICKET Uses one line on the ticket. Customize Ticket allows you to customize the preconfigured information printed on the delivery ticket. Choose from the following: 12 System Menu TCS 3000 Menu Example Prints Total Control Systems TCS 3000 Delivery Ticket (888) 888-8888 Programmable Field ———————————————Start Jun 04, 2012 09:42:09 AM End Jun 04, 2012 09:53:42 AM 3842 Meter 2 ######## Gasoline (Product setup in Prover) Header 1 Header 2 Header 3 Header 4 Header 5 Thick Separator Start Time End Time Truck ID Ticket Number Product Name ProdNet Total Begin ######## ProdNet Totalizer ######## ProdGrs Total Begin ######## ProdGrs Totalizer ######## SysNet Total Begin ######## SysNet Totalizer SysGrs Total. Begin SysGrs Totalizer Delivery Section Customer ID 1 Customer ID 2 Customer ID 3 Customer ID 4 Line Delivery Gross Begin Delivery Gross End Delivery Net Begin Delivery Net End TempComp Line Tempcomp Table Average Temp Gross Delivered Net Delivered Line Unit Price Sale Amount Tax 1 Tax 2 Tax Amount Star Line Amount Due Empty Line Thick Separator System Line 1 System Line 2 Footer 1 Footer 2 Footer 3 Footer 4 Footer 5 ######## ######## ######## —— Delivery —— Programmable Field Programmable Field Programmable Field Programmable Field ######## ######## ######## ######## Volume Corrected to 60F (15C) Table —— i.e. Table 24 AVG Temp. F Gross Gal. Delivered Net Gal. Delivered Unit Price —- i.e. 1.86 ######## Tax 1 —— i.e. Road Tax Tax 2 —— i.e. Sales Tax Tax Amount *********** Amount Due ———— ##.## ######## ————** Duplicate Invoice ** *** Power Loss *** Programmable Field Programmable Field Programmable Field Programmable Field Programmable Field 13 System Menu Add Ticket Type Create a NEW Customized Ticket, then press ENTER to name it. Copy from an Existing Ticket, then press ENTER to name it. NOTE: Any new ticket name must be 3 or more characters long Remove Ticket Type Select ticket to be removed from the system and press ENTER Header Defaults There are FIVE programmable fields for contact information or messages Footer Defaults There are FIVE programmable fields for contact information or messages Shift Ticket Headers There are FOUR programmable fields for contact information or messages Inventory Tickets Header There are FOUR programmable fields for contact information or messages PRESET SETTINGS Enable Preset Utilizing the preset will request a preset amount before a delivery begins. After selection, press ENTER to complete setting. Enable Preset Preset By Price Gross Preset Net Preset Retain Preset Enable or disable preset Enable or disable preset by Price Enable or disable preset in GROSS VOLUME Enable or disable preset in NET CORRECTED VOLUME Enable or disable preset for repeat BATCH presets MULTIPLE DELIVERIES Allows for the user to fill multiple tanks on one (1) single ticket transaction. Simply press and hold the SHIFT key down while pressing the START key to begin the multiple deliveries. If preset is enabled, each tank delivery will prompt the preset amount. CUSTOMER ID OPTIONS The Customer ID Option will provide four (4) separate fields for the user to input prior to the delivery. The Customer Identification is normally used for Tank, Truck, Airplane Tail No., Locomotive, Driver, Customer, etc. Manual entry of data will be required through the alpha-numeric keypad. After selection, press ENTER to complete setting. Customer ID# (1-4) Customer ID# Text Field programmable for identification Request ID# Field requires user to enter an ID Enforce ID# Field requires user to enter an ID in order to operate the system Validate ID# Field validates the ID to ensure the ID is in the database, if invalid the system will be inoperable DISPLAY PRECISION The unit precision can be displayed as a whole, tenth, hundredth or thousands measure ment. After selection, press ENTER to complete setting. 1 1.1 1.11 1.111 Whole Unit Tenth Unit Hundredth Unit Thousands Unit 14 Select Function ZERO FLOW TIMEOUT Feature will complete a delivery transaction if the user does not press the STOP key. Enter whole numbers in Seconds for the timeout setting and press ENTER. NOTE: Factory setting is 180 seconds, 3 minutes after the last pulse transmission to the TCS 3000 register. This feature CANNOT be disabled. For desired extended periods, utilizer a large number to have the Timeout ignored. PAUSE OPTIONS Pause controls how pump control is used. Allow Pause Allow Pause Pauses the pump during the delivery Pause Pump Pause Pump stops the delivery completely during delivery. 5) AUXILIARY DEVICES EXTERNAL DISPLAY The External Display setting is for the specific manufacturers of large LED displays. This setting is for serial communication to an ancillary display that will read the same data that is displayed on the TCS 3000 register. Enable/Disable Enable or disable and press ENTER Configure Select Type: Address: Display Data Test This is a test sequence of numbers to exhibit on external display Red Lion LD is currently the only external display available today Display Address from 1 to 99 and press ENTER Choose the information to display on External Display and press ENTER - Delivery Gross - Delivery Net - Delivery Volume - Delivery Total (Currency) - Flow Rate - Mass AIR ELIMINATOR The Air Eliminator is for the electronic actuation of a solenoid exhaust vent and a down stream valve, when a level sensor switches. AE Enable/Disable AE Detection AE Relay Enable or disable for operation Select Normally Open or Closed for level sensor detection Enable or disable exhaust vent solenoid valve actuation ADDITIVE INJECTOR This feature is not currently enabled 15 Select Function PULSE OUTPUT The solid state pulse frequency transmission of a scalable pulse factor Enable/Disable Enable or disable operation Configure Sets the DEFAULT for pulse transmission output data Delivery Total (Currency) Gross Volume 1 1.1 1.11 1.111 (1 pulse per unit) (10 pulses per unit) (100 pulses per unit) (1000 pulses per unit) Net/Auto Volume 1 (1 pulse per unit) 1.1 (10 pulses per unit) 1.11 (100 pulses per unit) 1.111 (1000 pulses per unit) Pulse Repeater repeats the incoming pulse value Startup Reset Enable or disable and press ENTER RFID READER RFID is for fixed location or fleet refueling External ThinkMagic External is used for remote readers ThinkMagic is for fixed locations CONNECTIVITY Connectivity is used for accessory communication settings Network Settings Interface Address Interface is for handheld communication. An interface is required for this setting. Device Address will assign the TCS 3000 the unique address within the Daisy Chain communication sequence. Primary Host will always be number one (1) and the Client Address range will be two (2) through eight (8). Printer Settings Enable/Disable Select Printer Printer Host Clients Address Range Enable or Disable for operation Select desired printer to be used with the system Enable or Disable a printer host Displays the range between Client and Host in a daisy chain. MISC SETTINGS L1 Password Level one (1) password protection for System Settings. Procedure to set L1 Password is as follows: 1. 2. 3. 4. Highlight L1 Password and press ENTER. Highlight Set Password and press ENTER. Input alphanumeric password and press ENTER. Confirm password entry by resubmitting password, and press ENTER. NOTE: Alphanumeric password must be at least three (3) characters long. 16 Select Function L2 Password Level two (2) password protection for System Settings. Procedure to set L2 Password is as follows: 1. 2. 3. 4. Highlight L2 Password and press ENTER. Highlight Set Password and press ENTER. Input alphanumeric password and press ENTER. Confirm password entry by resubmitting password, and press ENTER. NOTE: Alphanumeric password must be at least three (3) characters long. Access Key Access Key is used to lock or unlock the register keyboard when a Computer or Handheld device is in use. System Mode System Mode is used for databases Default MR1 Used for standard register mode Used for database User DB Update Used to update the database. Weights & Measures Settings NOTE: The Calibration bolt must be removed in order to enter calibration mode. To remove the bolt, unscrew the bolt with a 3mm Hex drive. Place calibration plate and screw in a safe location where it will not be lost. Under the calibration plate you will find a screw. Using the 3mm Hex drive, loosen the calibration screw. You do not need to remove this screw all the way. *If you lose the calibration screw, you will not be able to operate the register.* DO NOT LOSE THE SCREW BEFORE YOU CALIBRATE THE REGISTER YOU MUST ENTER A PRODUCT To Calibrate begin in section ADD NEW on Page 20. *NOTE: ALL PRODUCTS MUST BE CALIBRATED INDIVIDUALLY * PRODUCTS PRODUCT TEST RUN This allows you to run the product after you’ve calibrated in order to verify repeatability. Available Products Highlight the product you are calibrating and select ENTER. START automatically begins the product test run until you press STOP to finish. RECALIBRATE PRODUCT Available Products Highlight the product you want to re-calibrate and select ENTER. *If you need to modify the settings you originally selected for the calibration of a product select MODIFY PARAMETERS, if the settings were correct and you do not need to change them select BEGIN RECALIBRATION.* 17 Weights & Measures A) Modify Parameters Product Name Using the keypad type in the name of the product you are calibrating. If the product listed is correct select ENTER. To change the product name press Enter and input name as desired. Compensation Table Choose the correct Volume Temperature Compensation Table and press ENTER. See TABLE 2 for reference. Comp. Table Param. Input the correct Compensation Table Parameter and press ENTER. See TABLE 2 for reference. NOTE: this list references most common products, not an exhaustive list of every volume correction Product Name API Table Temp. Coefficient Value Range Mean Fuel Oil 6B Gasoline 6B Diesel 6B Kerosene 6B Jet A 6B Jet A-1 6B Av Gas 6B Refined Fuels 6B F Specific Gravity 0 — 85 Liquefied Propane Gas (LPG) 24 F Specific Gravity 0.500 — 0.550 0.510 Gasoline 54B C Density KG/m3 640 — 780 730 Diesel Oil 54B C Density KG/m3 780 — 1074 840 Fuel Oil 54B C Density KG/m3 830 — 900 840 Kerosene / Jet Fuel 54B C Density KG/m3 780 — 840 800 Stoddard Solvent 54B C Density KG/m3 780 — 800 790 Lubricating Oils 54B C Density KG/m3 850 — 905 880 TABLE 2 18 Weights & Measures Mass Density To provide a calculated Mass value, determine the value to input Mass Density and press ENTER. Mass = Density X Volume Unit of Measure Gram/cm3 Gram/Cubic Centimeter Gram/m3 Gram/Cubic Meter Kilogram/m3 Kilogram/Cubic Meter Milligram/m3 Milligram/Cubic Meter Pound/ft3 Pound/Cubic Foot Pound/in3 Pound/Cubic Inch Ton/yard3 Ton/Cubic Yard Pump Control & Timing Enable/Disable Pump Control and select ENTER. - Pump is an Optional Output Control - Enabled means that the pump control will energize whatever element of the truck you’ve connected to. - Disabled means that the pump control is not active and will not energize. Pump Starter to enter the Start Duration time in seconds, then press ENTER. Pump Starter Advance to enter Starter Advance time in Seconds, then press ENTER. Pump Stabilization is used to enter how long you wish the Pump Starter stays powered. Enter value in Seconds and press ENTER. Valve Type Select whether you are using a Single or Dual Stage Valve and press ENTER - A Single Stage valve will energize valve with Solenoid 1. - A Dual Stage valve will energize valve with Solenoids 1 and 2. DUAL -1101 Both S1 and S2 energize at the beginning of delivery and near the end of the delivery S1 shuts off and S2 is still operating. -1001 At the beginning of the delivery the S1 valve opens energizes while the S2 remains closed until near the end of the delivery, then S1 closes and S2 opens. 19 Weights & Measures Maximum Flowrate Input the maximum rated flow of flow meter and press ENTER. NOTE: this value is critical to the Valve actuation! Pulser Type Select the pulse input type (Single or Dual Channel) and press ENTER. Pulser Estimate Manual entry of the Meter Pulse Estimate (Meter Factor). Input pulse value and press ENTER. Product Units Select TCS 3000 register units of measure and press ENTER. Volume: Highlight Volume Unit and press ENTER. GAL L UKG daL mL m3 bbl USA Gallons Liters UK Gallons Dekaliter Milliliter Cubic Meter Barrel NOTE: Selecting Product Unit does not change the Totalizer unit of measure. See Page 21 for changing Totalizer unit of measure. Temperature: Highlight Temperature Unit and press ENTER F Fahrenheit C Celsius K Kelvin Currency: Select the Currency Symbol or Abbreviation and press ENTER. SYMBOL ABBREVIATION $ Dollar USD £ Pound EUR Euro ¥ Euro GBP British Pound Sterling CAD Canadian Dollar MXN Mexican Peso CLP Chilean Peso JPY Japanese Yen BGN Bulgarian Lev CHF Swiss Franc CZK DKK Czech Republic Koruna Danish Krone HUF Hungarian Forint LVL Latvian Lats LTL Lithuanian Litas PLN Polish Zloty RON Romanian Leu SEK Swedish Krona 20 US Dollar Weights & Measures Mass: Highlight the Mass unit and press ENTER. lbs Pounds oz Ounce t Ton kg Kilogram g Gram Hose Volume: Enter unit value for “packing” hose downstream of meter and press ENTER. Value will not display prior to setting and there will be no lost liquid. B) Begin Recalibration *NOTE: ALL PRODUCTS MUST BE CALIBRATED INDIVIDUALLY * Select Begin Recalibration to change the Meter Calibration Value. Press ENTER to begin calibration run. The display will prompt you to press START to begin automatic calibration of the flow meter. Press STOP when finished with a certified Weights & Measures volumetric or gravimetric proving system. Input Prover Value and press ENTER. When finished, a Calibration Summary screen will appear with the Gross Amount, Net Amount, Average Temperature, Compensation Table, Pulse/Second and Pulse/Volume (Meter Calibration Value). Press STOP to continue. Display menu will prompt you to continue with a Test Run? or to finish the calibration. Push SHIFT + START to begin Test Run to validate the Meter Calibration Value. Press STOP to finish. C) Edit Prod. Calibration Allows a manual calibration modification. A “WARNING” screen will then be displayed, press ENTER to continue to change Meter Calibration Value. - Select Product to manually change Meter Calibration Value. Adjust the current Meter Calibration Value by multiplying by the equation below. - Input value and press ENTER, which will display a “MODIFICATION” screen. Press any key to continue. % ERROR = Volume on Prover — Volume on Meter Display X 100 Volume on Meter Display D) Add New Before you can calibrate the register, you must enter a product. Select Add New and use the keypad to enter a product (e.g. LPG, Fuel Oil, Aviation Gasoline, etc.). Once you’ve entered your product, press ENTER. - All parameters for a New Product MUST be entered for the product to be accepted by the TCS 3000. Follow pages 17 through 19, under Modify Parame ters to complete the Add New product setup. Once the new product parameters have been entered, you will be required to calibrate the product. NOTE: A new product MUST be calibrated for it to be available as an Active product. Without calibration, the new product will only be seen in Product Settings LIST. 21 Weights & Measures E) Remove Product To remove an unwanted product from the TCS 3000, select and press ENTER. To confirm product removal, press MODE. NOTE: You must first End Shift and then Deactivate the product under Product Settings. 2) ACCOUNTING Select Accounting to set the Ticket Number. SYSTEM METRICS PRECISION 1 1.1 1.11 1.111 The unit precision can be displayed as a whole, tenth, hundredth or thousands measurement. After selection, press ENTER to complete setting. Whole Unit Tenth Unit Hundredth Unit Thousands Unit SYSTEM TOTALIZERS This function will allow the System Totalizers to be changed to zero (0). Press ENTER to proceed with change. Volume Unit Once the Totalizer has been changed, the display will prompt you to change the Unit of Measure for the Totalizer. Highlight the Unit of Measure and press ENTER. GAL USA Gallons L 4) TEMP PROBE Liters UKG UK Gallons daL Dekaliter mL Milliliter m3 Cubic Meter bbl Barrel This function is used to change the reference temperature of the meter system RTD temperature probe. Highlight Offset Calibration and press ENTER. Highlight Reference Temperature Unit of Measure and press ENTER. F Fahrenheit C Celsius K Kelvin Enter the correct temperature to recalibrate the Reference Temperature and press ENTER. 5) METER INFORMATION Selecting Meter Information allows you to enter the information off of your meter and register. This information is required for the Report Menu on page 10, as well as the Prover Tickets from Meter Calibration. 22 Weights & Measures REGISTER # Highlight Register # and input the TCS 3000 serial number located on the unit. Press ENTER when complete. TRUCK ID Highlight Truck ID to input the truck or tank number. Press ENTER when complete. NOTE: if there are multiple meters daisy chained together, the Truck ID and Meter sequence number should be input here. METER VERSION Highlight Meter Version and enter the manufacture. Press ENTER when complete. METER MAKE Highlight Meter Make and enter the meter manufacturer’s name and Press ENTER when complete. METER MODEL Highlight Meter Model and enter the assembly model number. Press ENTER when complete. METER SERIAL # Highlight Meter Serial # and input the meter serial number of the unit. Press ENTER when complete. SYSTEM ID Highlight System ID and input the system identification. Press ENTER when complete. 6) PROVER TICKET Selecting Prover Ticket allows you to Print the existing Prover Data from the TCS 3000. Select PRINT to print the Prover Ticket. 7) TICKETS CLEANUP Enabling Tickets Cleanup will allow the system to delete the oldest 500 non-printed tickets when there are more than 5000 non-printed tickets stored. *This Might Not Be Legal in Some Countries or States 8) RESET TOTALISERS System and Product Totalizers record the amount of all liquid that has passed through the meter by product. * Please Note * Resetting the Totalizers will reset the TCS 3000 Totalizers to zero. There is no way to recover totalizers once deleted. SYSTEM TOTALIZER System Totalizers record the amount of all liquid that has been measured. End Shift before resetting the System Totalizer. Highlight the System Totalizer and press ENTER. A “WARNING” will appear on the screen that you are about to reset the Totalizers. Press MODE to confirm the Totalizer reset. PRODUCT TOTALIZER Product Totalizers record the amount of liquid for a specific product that has been measured. You must End Shift and Deactivate Product in Product Settings (page 22) before resetting the Product Totalizer. Without doing so, the error “No Active Products” will be displayed. Highlight Product Totalizer and press ENTER. 9) ENABLE REMOTE CONFIG Allows you to connect the TCS 3000 to a F-RAMS handheld device to remotely control the Calibration of the register. - To Enable Remote Config make sure your F-Rams handheld is connected to the TCS 3000 register with the TCS 300859 quick disconnect cable kit). - Highlight Remote Config and select ENTER. This will enable the Remote Config setting and you will be able to calibrate your system. - When finished calibrating, press any key to exit. 23 Select Function —Product Settings 1) INVENTORY Inventory monitors how much product is in a tank. ADD INVENTORY Creates an Inventory “Tank” to be monitored. Here you will Name your Inventory “Tank” Enter in the Tank Capacity and Enter the Current Tank Level **Must be outside of a Shift to do this step** ASSIGN INVENTORY Allows you to Pair an Active Product to the Inventory Tank Created to be Monitored. **This must be done to track inventory levels** **Can be done during a Shift** UPDATE INVENTORY Allows you to correct the Inventory levels by manual entering the proper inventory level. Add to Inventory allows you to add to the current inventory when you are loading “X” amount of product to the tank Set Inventory Value allows you to change the inventory level to a specific amount Filling up the inventory to 100% Tank Capacity Emptying the Inventory to 0%. **Can be done during a Shift** VIEW INVENTORY Allows you to see your total inventory levels of numerous tanks on one display, See Individual inventory details, or print an Inventory Report **Can be done during a Shift** REMOVE INVENTORY Removes the Inventory Tank from being Monitored **Must be outside of a Shift to do this step** Shortcut to Inventory options from Delivery Screen Pressing Shift + Print will allow you to Update, Fill, or Empty Inventory Levels Quickly during a Shift After Adjusting the inventory you will be prompted to provide a Bill of Lading Number 2) PRODUCT PRICES Product Prices allows the price to be set for a specific product. For multiple products, pricing must also be changed. To set pricing, highlight the desired product and press ENTER. NOTE: if you have not changed the Product name, the factory default “DEMO” will be displayed. 24 Select Function UNIT PRICE Highlight Unit Price and press ENTER. Input the price value and press ENTER. TAX 1 NAME Highlight Tax 1 Name and press ENTER. Input tax name and press ENTER. TAX 1 TYPE Highlight Tax 1 Type and press ENTER. Use the navigation arrows to select Tax 1 Type and press ENTER. TAX 1 VALUE Highlight Tax 1 Value and press ENTER. Input tax value and press ENTER. None No tax will be entered. Percent Tax amount value is calculated as a percent (%). Per unit Tax is calculated per unit of measure. TaxTax Tax is calculated on a tax. TAX 2 NAME Highlight Tax 2 Name and press ENTER. Input tax name and press ENTER. TAX 2 TYPE Highlight Tax 2 Type and press ENTER. Use the navigation arrows to select Tax 2 Type and press ENTER. TAX 2 VALUE Highlight Tax 2 Value and press ENTER. Input tax value and press ENTER. None No tax will be entered. Percent Tax amount value is calculated as a percent (%). Per unit Tax is calculated per unit of measure. TaxTax Tax is calculated on a tax. CURRENCY Select the Currency Symbol or Abbreviation and press ENTER SYMBOL $ Dollar USD ABBREVIATION US Dollar £ Pound EUR Euro ¥ Euro GBP British Pound Sterling CAD Canadian Dollar MXN Mexican Peso CLP Chilean Peso JPY Japanese Yen BGN Bulgarian Lev CHF Swiss Franc CZK Czech Republic Koruna DKK Danish Krone HUF Hungarian Forint LVL Latvian Lats LTL Lithuanian Litas PLN Polish Zloty RON Romanian Leu SEK Swedish Krona 25 Select Function PREVIEW PRICING Preview Pricing will show the Product price and taxes. 3) ACTIVATE PRODUCT Activate Product allows you to activate a product for a specific Shift. When liquid in your tank changes, you can change the product and calibration to match. - To Activate a product, highlight the product and press ENTER. 4) DEACTIVATE PRODUCT Deactivate Product allows you to deactivate an active Shift product. When liquid in your tank changes, you can also change the product. 5) PRODUCT TIMING Product Timing allows auxiliary device settings to be changed to suite the needs of the application. Currently set up for Preset Valve, Air Eliminator Hold and Hose Volume. Product Timing is product specific, adjusting the actuation or closure type. PRESET TIMING Preset Timing adjusts the valve closure type for preset or security valves. Highlight the Preset Timing function desired and press ENTER. This will be chosen as your default setting for the specific Product. Full-Auto Full Automatic tune preset shutoff for Solenoid S1 (fast) and S2 (slow) flow valves. Semi-Auto Semi-Automatic tune preset shutoff for Solenoid S2 (slow) flow valve. Highlight Semi Auto and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER. Next Fix Next Fix is an automatic tune shutoff, however it will allow the preset to overrun batch amount. Designed to automatically correct the shutoff on the next preset delivery. Highlight Next Fix and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER. Static Static settings for the Solenoid S1 (fast) and S2 (slow) flow valves. There is no automatic correction for zero point shutoff. Highlight Static and press ENTER. Input Solenoid S1 (fast) flow valve closure and Solenoid S2 (slow) flow valve and press ENTER. AIR ELIMINATOR HOLD When the TCS 3000 senses air, it will actuate the Solenoid S1 and S2 to shut off and open the Auxiliary Relay for the exhaust port to remove air from the system. Highlight Air Eliminator Hold and press Enter. The HOLD (s) is the adjustable setting for the Auxiliary Relay closure in Seconds. Input value in Seconds and press ENTER. STARTUP VOLUME 6) PROUCT LISTS Displays a list of Active, Inactive and Un-Calibrated products on the TCS 3000. To view these Products, highlight the selection and press ENTER. 26 Select Function —Advanced Functions LOCK THE SYSTEM SYSTEM SHUTDOWN System Shutdown Shuts the TCS3000 down. You must cut power to the TCS 3000 and reboot to turn the unit back on. SYSTEM UPDATE System Update allows you to upgrade the TCS 3000 Software. NOTE: Update process does NOT change Weights & Measures settings or parameters. Procedure to upload new software is as follows: 1) Load new software upgrade to a USB thumb drive (dongle). NOTE: The new software upgrade should be the ONLY file on the drive. 2) Open the TCS 3000 register. On the front cover of the register, there are 2 mini-USB connections.. Using a factory supplied USB cable, attach the thumb drive to the USB port closest to the inside of the register. This port is the highest on the circuit board of the two. See Figure 1. 3) Plug the USB cable into the USB port, and then insert the USB thumb drive into the mating cable (see Figure 1). 4) Under Advanced Functions, locate System Update and press ENTER. 5) The screen will display System Update, press MODE to continue with the update. 6) If the thumb drive is not recognized or there is a faulty cable, the display will respond with NO UPDATE DATA error message. 7) Once the file is recognized, the operating system will begin the update process. This should take approximately 4 minutes. NOTE: Do not power down or pull USB thumb drive until the TCS3000 tells you to do so. 8) You may remove the USB cable and close the TCS 3000 register once the Update is Complete. FIGURE 1 Mini USB Port Male Mini USB to Female USB USB Thumb Drive with communication LED 27 “Must Know” & How To Installation Procedure—Daisy Chain Daisy Chain: Daisy Chain is used for linking multiple registers together to use one printer or to link multiple registers to the database. To Daisy Chain the Registers use a two wire 22 gauge shielded cable. Nominate one Register to be the Host. Once you’ve chosen which Register will be the Host the other Registers will be considered the clients. Strip a small amount of wire and run the wire from slot A and B of DAISY CHAIN on the Host Unit to slot A and B of DAISY CHAIN on the Client Unit. To tie the Client to the next Client unit on the Daisy Chain, strip a small amount of wire and run the wire from slot A and B of DAISY CHAIN to slot A and B of the next client’s DAISY CHAIN. B A B A Host The Host will have 2 wires. B A Client 2 Client 2 will have 4 wires. B A Client 3 Client 3 will have 4 wires. Client 4 The Last Client will have 2 wires. B B B B A A A A Continue to Daisy Chain until you have tied the chain together, alternating slots on the Daisy Chain until you’ve reached the end of the chain. The Host and the last Client on the chain will be the only two registers on the chain to have a one wire connection. 28 “Must Know” & How To Daisy Chain for the Printer Connect the Printer to the Host Register. To set the Host : Enable the Printer: SYSTEM MENU → SYSTEM SETTINGS → PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER Select the Printer: PRINTER SETTINGS → SELECT PRINTER → [SELECTED PRINTER] → ENABLE Selecting the Host Register Select Register as Host: PRINTER SETTINGS → DISABLE/ENABLE HOST → ENABLE Select the Client Range: PRINTER SETTINGS → PRINTER HOST → CLIENTS ADDRESS RANGE → CLIENTS RANGE START ADDRESS [ Enter 2 and Select] → CLIENTS RANGE END ADDRESS [ Enter the number of Registers on the Chain and Select] *Please Note the Host is always # 1. The Client always starts at #2* Selecting the Client Register *If you are not using the Daisy Chain for the Printer Please Disregard the Enabling and Selecting the Printer Steps. Enable the Printer:* PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER Select the Printer:* PRINTER SETTINGS → SELECT PRINTER → [REMOTE] → ENABLE SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → ADDRESS → DEVICE ADDRESS [Select the number of the unit you are using ex. 2 if it is the second register on the chain or 3 if it’s the third register on the chain.] To Connect to the Chain: SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → INTERFACE BRIDGE [Only used when there are 2 Registers tied in the chain] → TRANSFER DATA BETWEEN RS232 <-> RS485 INTERFACES ENABLED Continue the Selecting Client Register steps for every Client on the Chain. You may only use the Daisy Chain on five devices at a time. You may not Chain more than five devices together. 29 “Must Know” & How To Installation Procedure—Daisy Chain Modem Daisy Chain: Daisy Chain is used for linking multiple registers together to use one printer or to link multiple registers to the database. To Daisy Chain the Registers use a two wire 22 gauge shielded cable. Nominate one Register to be the Host. Once you’ve chosen which Register will be the Host the other Registers will be considered the clients. Strip a small amount of wire and run the wire from slot A and B of DAISY CHAIN on the Host Unit to slot A and B of DAISY CHAIN on the Client Unit. To tie the Client to the next Client unit on the Daisy Chain, strip a small amount of wire and run the wire from slot A and B of DAISY CHAIN to slot A and B of the next client’s DAISY CHAIN. B A B A Host The Host will have 2 wires. B A Client 2 Client 2 will have 4 wires. B A Client 3 Client 3 will have 4 wires. Client 4 The Last Client will have 2 wires. B B B B A A A A Continue to Daisy Chain until you have tied the chain together, alternating slots on the Daisy Chain until you’ve reached the end of the chain. The Host and the last Client on the chain will be the only two registers on the chain to have a one wire connection. 30 Selecting the Host Register Select Register as Host: PRINTER SETTINGS → DISABLE/ENABLE HOST → ENABLE Select the Client Range: PRINTER SETTINGS → PRINTER HOST → CLIENTS ADDRESS RANGE → CLIENTS RANGE START ADDRESS [ Enter 2 and Select] → CLIENTS RANGE END ADDRESS [ Enter the number of Registers on the Chain and Select] *Please Note the Host is always # 1. The Client always starts at #2* Selecting the Client Register Enable the Printer:* PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER Select the Printer:* PRINTER SETTINGS → SELECT PRINTER → [REMOTE] → ENABLE SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → ADDRESS → DEVICE ADDRESS [Select the number of the unit you are using ex. 2 if it is the second register on the chain or 3 if it’s the third register on the chain.] To Connect to the Chain: SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → INTERFACE BRIDGE [Only used when there are 2 Registers tied in the chain] → TRANSFER DATA BETWEEN RS232 <-> RS485 INTERFACES ENABLED Continue the Selecting Client Register steps for every Client on the Chain. You may only use the Daisy Chain on five devices at a time. You may not Chain more than five devices together. 31 Real Time Inventory How To Manual Inventory How To *Please note, you must End Shift before you may Add or Remove Inventory* Real Time Inventory is for Automatic Tank Levels Only Add Inventory: Add Inventory: While holding Shift select Mode → System Menu → Product Settings → Inventory → Add Inventory →GIVE INVENTORY NAME (Use the Keypad to assign a name, ex. Av Gas, Gasoline, etc.) → Select Unit Volume (Gallons, Liters) → ENTER CAPACITY (Tank Size) → ENTER INVENTORY (Actual Known Inventory) → Press Any Key to Continue While holding Shift select Mode → System Menu → Product Settings → Inventory → Add Inventory →GIVE INVENTORY NAME (Use the Keypad to assign a name, ex. Av Gas, Gasoline, Tank 1, Tank 2, etc.) → Select Unit Volume (Gallons, Liters) → ENTER CAPACITY (Tank Size) → ENTER INVENTORY (Actual Known Inventory) → Press Any Key to Continue Assign Inventory: Assign Inventory: Assign Inventory → Select an Active Product → Assign the Active Product to an Inventory List → Press Any Key to Continue Assign Inventory → Select an Active Product → Assign the Active Product to an Inventory List → Press Any Key to Continue *Please Note You can apply multiple inventories to one meter.* *Please Note You can apply multiple inventories to one meter.* Update Inventory: Update Inventory: Update Inventory → ADD To Inventory → ENTER AMOUNT (Amount added to tank) Update Inventory → Level Meter → Select CH# (Ex. If Product 1 is tied to CH2, then you select LVL2) → Set Inventory Value → ENTER CURRENT VALUE (Current amount of product in the tank) Inventory Update Message → Press Any Key to Continue Fill Up Inventory → Press Any Key to Continue (Resets Inventory to full capacity) *Please Note: Use CH2-6* Empty Inventory → Press Any Key to Continue (Zero’s out tank amount) *Also Note: Level Meter will only update when there is no movement.* To Check the Changes: Remove Inventory: Update Inventory → Level Meter →The LVL# you selected should be highlighted. Remove Inventory → Select Inventory → Press Mode to Confirm *If you enter into this screen and None is highlighted, then the unit does not see the circuit board or the Madison Gauge. Print Inventory Report: View Inventory → Print Inventory Report A ticket will generate if a printer is set up. Bill of Lading: Remove Inventory: Once you have finished in Inventory, select STOP/CANCEL → Remove Inventory → Select Inventory → Press Mode to Confirm ENTER BILL Nr. → START/ENTER Print Inventory Report: Inventory Short Cut View Inventory → Print Inventory Report In the Delivery Screen: Hold down SHIFT and select PRINT (while holding Shift) Bill of Lading: You can enter inventory through the short cut only after you’ve set up and assigned inventory. Once you have finished in Inventory, select STOP/CANCEL → ENTER BILL Nr. → START/ENTER Color Guide: Blue: Operating Volume Yellow: 25% Cautionary Volume 32 Red: 10% Low Volume “Must Know” & How To TEMPERATURE PROBE CALIBRATION HOW TO * The following is based on product(s) you have calibrated. You must select the compensation table and the temperature unit for the product when Calibrating your product in order to Calibrate Temperature.* Press Shift and Mode to enter the Select Function Screen. Use the arrow keys to highlight SYSTEM MENU and Select START/ENTER. *Remove the Calibration Bolt and set in a safe location.* *Note: You will want to take 3 temperature readings during a run to get the average temperature. Use the arrow keys to highlight W&M SETTING. Select START/ENTER. Use the arrow keys to highlight your product. Select START/ENTER. Use the arrow keys to highlight PRODUCT TEST RUN. Select START/ENTER. Use the arrow keys to highlight your product. Select START/ENTER. Enter the Average Temperature Select START/ENTER *Note: The register will display that it is calibrating and is applying the corrections. It will take a minute to calibrate the RTD Probe to the Weights & Measures Probe. When Calibration is done the Register will display the following message: Use the arrow keys to highlight TEMP PROBE select START/ENTER. Repeat the steps if necessary. Selecting TEMP PROBE will take you to Offset Calibration Press START/ENTER (You are now calibrating the TCS3000 Register Temperature Probe to the Weights and Measures Temperature Probe) Use the arrow keys to highlight the Reference Temperature select START/ENTER. 33 Trouble Shooting Trouble Shooting To comply with Weights & Measures requirements, it is necessary to start and stop each delivery with a fully packed hose. Normally, this will be the case. However, there are times where the hose is not fully packed (e.g. after a preset delivery). As such, the hose must be packed and the register zeroed prior to making the next deliver. NOTE: This procedure will not work for an empty or dry hose. If more than 1 gallon or 5 Liters of liquid is required to pack the hose, a delivery ticket must be printed. To pack the hose at the start of a delivery: Press the Start Button, this energizes the solenoids. Allow the pump to pack the hose. TCS 3000 Trouble Shooting Guide The TCS3000 troubleshooting guide covers most common problem situations. Call your Total Controls Service Center for any problems that are not covered in this guide. NOTICE DANGER It may be necessary to break Weights & Measure seals to perform certain troubleshooting steps in this guide. Contact your supervisor or local Weights & Measures authorities for information before breaking any seals. Serious Injury or Death may Result – Fire, Explosion, and Electrical Shock Hazard. Only trained and authorized personnel should perform troubleshooting. Use extreme caution when troubleshooting and taking all electrical measurements. Be sure that equipment is in a well ventilated area and that hazardous or flammable vapors are not and will not be present during testing. If equipment is located in a hazardous environment, it may be necessary to remove the equipment and perform troubleshooting in a safe area. Trouble Shooting Guidelines: 1) Before attempting to troubleshoot the TCS 3000 system, become familiar with the operation and set-up of the specific installation. 2) Make sure all electrical connections are secure and tight. 3) Make sure all terminal blocks are firmly connected. 4) ALWAYS use a good digital multimeter. Voltage levels are critical to proper system operation. Use an accurate, reliable multimeter to test for proper voltages at the start of any service procedure. Voltage requirements are listed under each component. NOTE: Check for proper operating voltages before changing the circuit board. If the circuit board needs to be changed, be sure to remove all power to the TCS 3000. 5) If an error occurs during a delivery, the message will appear on the Display and print on the delivery ticket. The delivery ticket will print an error message that can be useful in troubleshooting. This ticket will automatically print. Examine the prover ticket to make sure all set-up fields are accurate, e.g. pulses per unit volume, temperature coefficient, and base temperature. 6) NEVER remove a terminal block or jumper with the power on. 7) NEVER install a terminal block or jumper with the power on. 34 Trouble Shooting 8) NEVER force a terminal block into its location. 9) NEVER exchange or reposition terminal blocks on the circuit board. 10) In case of a major problem such as a burned or water-damaged circuit board, evaluate possible causes before replacing it and turn the power back on. 11) Isolate the problem before changing the circuit board. 12) Return faulty circuit boards with the proper forms, concisely completed. There may be several probable causes for a system malfunction. Listed on the next 3 pages are several probable causes to aid in returning the system to operation as quickly as possible. The list is not all-inclusive and should only be used as a guide. PROBLEM PROBABLE CAUSE SOLUTION Unit will not power up or there is no display Inadequate supply voltage. +9 to 28 VDC is required for operation 1. With the key in the accessory position, check the battery voltage to the circuit board. Use the negative terminal as DC ground. While the TCS 3000 will power-up at +9VDC, it is recommended that the input be at least +12.6VDC. 2. Check the 7.5A, in-line fuse for continuity. It is located in the accessory power line. Replace if necessary. 3. If the green light blinks fast it is doing what it is supposed to, but then it will go to a slow blink. If you see red, then you do not have enough power on the register. It must see a minimum of 9vdc. 4. If the red light comes on and the unit doesn’t power-up. Check the voltage if the voltage is OK but the temperature is -20 this will indicate that the heater is warming the display to prevent any damage to the VGA display and should come-up shortly Unit blow 7.5A Fuse +12 VDC battery line is shorted to ground 1. For safety reasons, remove the 7.5A, in-line fuse from the accessory power cable. 2. Unscrew the 3 pin power connector. Inspect for stray wire strands and visible shorts. 3. Inspect the full length of the power cable. Look for damaged insulation, which may cause shorting between the cable and ground potential (e.g. truck frame or chassis). If the power cable is damaged, it must be replaced. 4. Replace the 7.5A fuse and re-install the wires into the terminal connector. 5. If the 7.5A blows again, then replace the power cable. 6. If the 7.5A fuse blows after replacing the power cable, then replace the TCS 3000 terminal circuit board. 35 Trouble Shooting PROBLEM PROBABLE CAUSE SOLUTION Power Failure appears on the delivery ticket Power to the TCS 1. Check accessory power cable for damage. Ensure that the power, common 3000 interrupted durand ground wires on power connector are secure. Located on the right hand ing delivery. corner of the terminal board 2. Turn on all truck accessories (headlamps, 2 way radio, heater, etc.). Engage the hose reel and monitor the DV voltage at ## using terminal ## as positive Static Discharge and terminal ## as ground. If the voltage drops below +10VDC, the truck electrical system may not be adequate to handle the current load for the TCS 3000. It may be necessary to upgrade the electrical system to accommodate the 3-amp TCS 3000 current requirements. 3. Verify proper grounding of the TCS 3000. Refer to the TCS 3000 Installation Manual for proper grounding procedures. Epson printer Low voltage to the release light Epson Printer flashes 1. Check the battery voltage for a minimum of +12.6VDC. 2. Under extreme cold conditions, the printer may not operate. Warm up the cab of the vehicle. 3. If the release light continues to flash, replace the Epson 295 Printer. No power indicator lights to the Epson Printer No power to the Epson printer 1. Verify that the power switch is in the ON position. This switch is located on the left-hand side of the Epson 295 Printer. 2. Check the printer power cable to ensure that it is seated properly. If the problem persists, replace the power cable followed by the Epson printer. “Temperatur e Error” appears on the TCS 3000 display Open or shorted circuit between RTD probe and the TCS 3000 1. Check the RTD Probe and terminal block for continuity. 2. Remove terminal block Temp Probe from the circuit board. On the terminal block, measure and record the resistance between the following pins: PIN READING Red to White 100 Ω ±20? 3. If the readings are not within the above tolerances, replace the RTD probe. Product flow Pulser shaft is not does not reg- turning with product ister on TCS flow. Pulse Failure 3000 Pulser Failure, register is not reading gallons or liters 1. Manually spin the pulser shaft and monitor the TCS 3000 display. 2. If the TCS 3000 displays counter increments, this may indicate a mechanical problem. Contact your TCS 3000 Service Center for assistance. 3. If the TCS 3000 display counter does not increment, see Pulser Failure. Missing pulse 1. Check the pulser output. counts. 2. Open the TCS 3000 cover by loosening the two bolts that hold the cover Excessive reversals closed. Using a reliable multimeter, measure the following DC voltages on terminal block is connected to the circuit board. Use terminal as ground referNote: Pulser faults ence. generally occur in a high vibration envi3. TERMINAL PULSER VOLTAGE ronment. TCS is not +0 VDC responsible for puls+5 VDC er failures caused by +3.74 TO 0 VDC TAHA1 WHILE SPININING excessive vibration. +0 TO 3.74 VDC TAHB1 WHILE SPINNING 4 If the following voltages are observed, check for loose pulser wiring connections. If no loose connections are found, replace the encoder. 5 Insert a ticket into the Epson printer. Begin a delivery. With product flowing through the meter, measure the following DC voltages on the terminal block. 6 TERMINAL PULSER VOLTAGE +0 VDC +5 VDC +3.74 to 0 VDC TAHA1 WHILE SPINNING +0 to 3.74 VDC TAHB1 WHILE SPINNING 36 Trouble Shooting PROBLEM PROBABLE CAUSE SOLUTION Valve will not open Solenoids are inac1. Insert a delivery ticket into the Epson printer and start a delivery. tive or inoperative. 2. Start a delivery and listen for the audible clicking sound from the solenoids. Foreign debris in sys- 3. If there is NO audible click form the solenoid, check the voltage to Pin + tem and 0 V of terminal block Solenoid 1. While the TCS 3000 is still in delivery, use a reliable multimeter to measure the following DC voltages on the circuit board. Use 0 pin as a ground or frame ground. 4. If there is an audible click from the solenoid (but still no flow), this may be an indication of a mechanical problem with the main valve or its associate components. Contact your TCS3000 Service Center. TERMINAL SOLENOID 1 for 2 VOLTAGE 9.0 VDC with plug remove VDC 2..0 VDC with solenoid connect 12.0 VDC with the solenoid energized 5. If the above voltages are correct, this may be an indication of a problem with the valve or its associated components. Contact you TCS 3000 Service Center for assistance. 6. If the above voltage are NOT correct, replace the following components with known working units until the problem is resolved: Solenoids 7. TCS 3000 Circuit Boards Product has wrong Name The Register was never calibrated or had the name changed in W&M Settings. Go into prover and calibrate the product or change the Name. Valve doesn’t shut off Valve was never set up or calibrated Select the product and calibrated the valve for zero shutoff. Display is read- Channel A and B are Switch wiring between Channel A and B ing in reverse wired backwards Daisy chain Network Address of communication registers are not in is not working proper sequence Host and Client Addresses are not in proper sequence Totalizers are incorrect 1. Check the RX and TX wiring between registers. 2. Make sure the printer is wired to the primary HOST register. 3. Check the Device Addresses of each register, with the primary HOST as 1 and CLIENTS from 2 to 8. 4. Make sure the primary HOST register has the Client Address Range set to communicate with all the TCS 3000 registers in the daisy chain. Product vs. System Totalizer 1. The Product Totalizer was not reset when the System Totalizer was reset to zero. 2. The ticket is configured to print the Product Totalizer instead of the System Totalizer, or visa-versa. Ticket is configured to show Product To- 3. The ticket is configured to print the Net Compensated Totalizer instead of talizer instead of Systhe Gross Uncompensated Totalizer, or visa-versa. tem Totalizer Net vs. Gross Totalizer Cant begin a delivery because the screen reads “Delivery Not Completed” Last delivery had the printer enabled, but the ticket had not printed. The delivery ticket must be printed when the printer is communicating with the TCS 3000. To move on without the printer, either disable the printer or have the Select Printer changed to None under Printer Settings. You will be able to Re-print Tickets under the Select Function. 37 “Must Know” & How To Start Up “Must Knows” for Setup Configuration & Calibration 1) Each Product must be thoroughly configured and calibrated in W&M Settings. There are many parameters that need to be configured to ensure your system operates properly. Failure to complete the Product Configuration may result in the TCS3000 to not function correctly. 2) Products that have been calibrated may appear either as an Active or Inactive Product. The TCS 3000 must have at least 1 Active Product in order to Begin a Shift and Start a Delivery. Products may only be Activated or Deactivated after a Shift has Ended. 3) The Calibration Screw must be threaded completely into the Calibration setting, or you will not be able to begin a shift or start a delivery. 38 Warranty Information —Warranty Information WARRANTY New 3000 electronic registers, equipment or components manufactured by Total Control Systems, a division of Murray Equipment, Inc. (TCS) with which this warranty is enclosed, are warranted by TCS to the original purchaser only for a period of TWELVE (12) months from installation or eighteen (18) months from the date of shipment, to be free, under normal use and service, from defects in material and workmanship. Defects occurring within the stated warranty period, TCS will repair or replace, at TCS’s option; provided that part or parts are returned to TCS transportation charges prepaid, and TCS’s examination discloses the parts or workmanship to have been defective upon delivery to the purchaser. EXCLUSIONS Warranty does not cover any parts and equipment not manufactured by TCS, but these items may be covered by separate warranties of their respective manufacturers. This warranty does not extend to any equipment that has been subjected to misuse, negligence or accident or if operated in any manner other than in accordance with TCS’s operating instructions and specifications. CLAIM PROCEDURES In order to obtain performance by TCS of its obligations under this warranty, the original purchaser must obtain a Return Goods Authorization (RGA) number from TCS’s customer service department within 30 days of discovery of a purported breach of warranty, but not later than the expiration of the warranty period. Once authorization is received, return the defective meter, piece of equipment, or component covered by this warranty, with transportation charges prepaid, to TCS at the address shown below together with a written statement setting forth the nature of the defect and RGA number. LIMITATIONS THERE ARE NO OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED. TCS SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE. TCS will determine if all parts or meter defect falls within the warranty guidelines and will repair or replace within a reasonable time span. TCS is not responsible for any in or out bound freight. TCS's sole obligation that shall represent the buyer's sole and exclusive remedy shall be to repair or at TCS's option to replace any product or part determined to be defective. In no event shall TCS be liable for any special, direct, indirect, incident, consequential or other damages of similar nature, including without limitation, loss of profits, products, production time, or loss of expenses of any nature incurred by the buyer or any third party. TCS has not authorized on its behalf any representation or warranties to be made, nor any liability to be assumed except as expressly provided herein; there is no other express or implied warranty. DESIGN AND EQUIPMENT CHANGES Any changes in design or improvements added shall not create any obligation to install same on equipment previously sold or ordered. 39 TCS900040 REV. 7 2/24/15 2515 Charleston Place Fort Wayne, IN 46808 Toll Free: (800) 348-4753 Phone: (260) 484-0382 Fax: (260) 484-9230 Email: sales@tcsmeters.com Website: www.tcsmeters.com PETRO Contact Information AFRICA South Africa Factory 1 - 16 Bentonite Street Alrode, Alberton, Johannesburg South Africa P: +27 (0)11 864 7758 F: +27 (0) 11 864 1649 E: sales@petroindustrial.co.za AUSTRALIA Eastern Australia Factory 2, 106 Potassium Street PO Box 407 Narangba QLD 4504 P: 07 3204 9558 F: 07 3293 4852 E: sales@petroindustrial.com.au Western Australia 2 Competition Way Wangara WA 6065 P: 08 6305 0855 F: 08 6305 0319 E: saleswa@petroindustrial.com.au CANADA Alberta Bay A, 233175 Range Road 283 Rocky View, AB T1X 0J9 PO Box 75148 Calgary Alberta T3H 3M1 Canada P: +1 403 998 7190 TOLL FREE: 1855 44 PETRO F: +1 403 770 8065 E: sales@petroind.ca UAE Dubai Office LB17330, Lobby Building 17 Jebel Ali Free Zone PO Box 18602 Dubai, United Arab Emirates P: +971 488 76688 F: +971 488 76932 E: salesuae@petroind.com PETRO petroind.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Erin McIntosh Create Date : 2015:02:26 12:26:46-05:00 Modify Date : 2015:07:14 08:25:44+10:00 Has XFA : No Language : en-US Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Format : application/pdf Creator : Erin McIntosh Creator Tool : Microsoft® Publisher 2013 Metadata Date : 2015:07:14 08:25:44+10:00 Producer : Microsoft® Publisher 2013 Document ID : uuid:c3610e44-3093-694a-98f5-ba17ce0ebabb Instance ID : uuid:4a279cc8-e96f-e347-97ef-cafb7db4d3e2 Page Count : 41EXIF Metadata provided by EXIF.tools