PETRO METER TCS 3000 Register Operations Manual

User Manual: manual pdf -FilePursuit

Open the PDF directly: View PDF PDF.
Page Count: 41

DownloadPETRO METER TCS 3000 Register Operations Manual
Open PDF In BrowserView PDF
Catalog Title

TCS 3000
REGISTER

Catalog Subtitle

Setup & Operation Manual

Table of Contents
Table of Contents
Receipt & Inspection
Notice
Introduction
System Specifications
TCS 3000 Start Up
Navigation
Navigation (Continued)
Display Icons
Select Functions
Start Delivery
Show Last Delivery
Begin or End Shift
Duplicate Shift Ticket
Re-Print Tickets
System Menu
Reports
Show Prover Status
Prover Ticket
Meter Info
Version Info
Memory Status
Display Settings
Display Settings
Printer Settings
Enable / Disable Printer
Select Printer
Enable / Disable Host
Clients Address Range
Regional Settings
Delivery Settings
Configure Ticket
Configure Ticket (Continued)
Accounting
Presets
Multiple Deliveries
Customer ID
Display Precision
Zero-Flow Timeout
Auxiliary Devices
External Display
External Display (Continued)
Air Elimination
Additive Injection
Pulse Output
Connectivity
Misc. Settings

2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
9
10
10
10
10
10
10
10
11
11
12
12
12
12
12
12
12
13
14
14
14
14
14
15
15
15
15
15
15
16
16
16

W&M Settings
Products
Product Test Run
Recalibrate Product
Modify Parameters
Product Name
Comp. Table
Comp. Table Param.
Mass Density
Pump Control
Valve Type
Maximum Flow
Pulser Type
Pulse Estimate
Product Units
Product Units (Cont.)
Hose Volume
Begin Recalibration
Edit Calibration
Add New Product
Remove Product
System Metrics
Temp Probe
Meter Information
Prover Ticket
Reset Totalizers
Enable Remote Config
Product Settings
Product Prices
Product Prices (Continued)
Activate Product
Deactivate Product
Preset Timing
Preset Timing
Air Eliminator Hold
Hose Volume
Product Lists
Advanced Functions
System Shutdown
System Update
Start Up “Must Knows”
Inventory How To
Daisy Chain
Daisy Chain (Continued)
Temperature Probe Calibration
Trouble Shooting
Trouble Shooting (Continued)
Trouble Shooting (Continued)
Trouble Shooting (Continued)
Notes
Notes
Warranty

2

17
17
17
17
18
18
18
18
19
19
19
20
20
20
20
20
20
21
21
21
22
22
22
22
23
23
23
24
24
24
26
26
26
26
26
26
26
27
27
27
28
29
30
31
32
33
34
35
36
37
37
39

Receipt & Inspection
Upon receipt of register shipment, be sure to inspect the packaging and the register assembly for any damage before signing the receipt of the shipment. Notify the delivery company about possible damage and refuse receipt of
the shipment.

Registers are individually boxed and are protected with static resistant packing material. Each package is identified
with the register assembly part number, description, serial number. Verify the register model is the correct model,
size, and configuration as ordered. Contact your distributor if there is any discrepancy or question.

Register assemblies should be handled with appropriate methods for the size and weight involved. Appropriate
clothing and shoes need to be utilized. Transport the register package to the installation site with appropriate transportation methods, careful not to damage the register.

Be careful of any loose or protruding staples from the packaging, as they can be very sharp and may potentially
cause injury.

If foam has been used to protect register, carefully remove top foam layer before attempting to remove register assembly from box. Foam packaging maybe formed around the register assembly making it difficult to remove. Do
not lift the register assembly by wires or anything other than the metal body of the register. Do not insert objects or
cables into the register unless stated. Removing register assembly from packaging without adhering these warnings may cause serious injury to you and/or the register.

Appropriate precautions should be taken regarding any personal, environmental and material compatibility with the
end use system.

Notice
Total Control Systems (TCS) shall not be liable for technical or editorial errors in this manual or omissions from this manual.
TCS makes no warranties, express or implied, including the implied warranties of merchantability and fitness for a particular
purpose with respect to this manual and, in no event, shall TCS be liable for special or consequential damages including, but
not limited to, loss of production, loss of profits, etc.

The contents of this publication are presented for informational purposes only, and while every effort has been
made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied,
regarding the products or services described herein or their use or applicability. We reserve the right to modify or
improve the designs or specifications of such products at any time.

TCS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper
selection, use and maintenance of any TCS product remains solely with the purchaser and end-user.

All rights reserved. No part of this work may be reproduced or copied in any form or by any means –
graphic, electronic or mechanical – without first receiving the written permission of Total Control Systems,
Fort Wayne, Indiana USA.

3

Introduction
The TCS 3000 register is a fully integrated custody transfer flow computer that will control all vehicle delivery operations.
The Open Software Architecture provides the option of a simple “Pump & Print” delivery or a custom measurement solution. The TCS 3000 features a 4.5”x 3.5” full color VGA display screen, multiple delivery screens and a flexible mounting
with backlit alpha-numeric keypad for the user interface. Available in flexible mounting configurations of 75 or 90 degree
displays for meter mounting, and a remote mounting.
As an flow computer with open software architecture, there will always be a need to add features to the register as the
industry applications evolve. Therefore please be reminded to contact the factory for periodic updates.
The TCS 3000 electronic register is a fully integrated flow computer that will control all delivery operations. The modular
design and open software architecture provide you with a tailored system that is expandable for future needs. The TCS
3000 features a large easy view VGA screen, alpha-numeric keypad and open printer interface for simple “Pump and
Print” deliveries. Software features offer complete flexibility of delivery screen information and view, preset, price/tax,
ticket format and password protection.
Optional GPS, Bluetooth, Wi-Fi and Cellular capability enables the TCS 3000 to improve your product security and ease
access to your delivery data to reduce your operation costs. Many additional features are available (multiple product
delivery, additive injection, density/temperature correction, multiple valve & pump control, etc.) to enhance your measurement solution.
TCS 3000 - This manual will help guide you with the setup confirmation and calibration of the register. Additional information will be provided for wiring instruction and auxiliary devices to integrate into the register.

System Specifications
ELECTRICAL
Power:

12—24V, 4A DC INPUT

A fuse shall be provided in the field to limit the 12VDC power source to 4 amps max.
Current:
Solid State Relays:

1.4 Amp
12/24 Vdc; Passive Solid State

INTERNAL PULSER
Pulse Ratio
Power
Hertz

400:1 PPR; Quadrature
5 Vdc
0 — 5000 Hz

EXTERNAL PULSE INPUT
Type
Power

Single or Dual Channel (Quadrature)
5 Vdc

ENCLOSURE
Aluminum die cast with epoxy powder coat
Built to Ingress Protection 66 and Nema 4 ratings
Temperature Range:
-40 F to 158 F (-40 C to 70 C)
Ports:
Ten 1/2” NPT UL, cUL threaded connection ports, ATEX
Backlit LED Keypad
Calibration optical switch, password and mechanical seal
UL/cUL Rating
Class 1, Division 2, Group C + D
The USB0 and USB1 connectors are for maintenance only. To access these connectors, power to the unit is to be
Disconnected or the area known to be free of ignitable gas or equivalent.
COMMUNICATION
Four RS 485 output, 2-wire half duplex, custom protocol; 9600 baud, 8 bit, no parity, 1 stop bit
One RS 232 output, 9600 baud; 8 bit, no parity, 1 stop bit
4

WARNINGS:
SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS C AND D HAZARDOUS LOCATIONS, OR UNCLASSIFIED
LOCATIONS.
WARNING– EXPLOSION HAZARD– DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS
WARNING– EXPLOSION HAZARD– SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS
1, DIVISION 2.

TCS 3000 Register Start Up:
Before placing this register into service you will receive a warning when you turn on the register
to calibrate the device before using. It will read as follows:
Caution
Before Placing this product into service, make sure that the register
has been properly calibrated and setup for the type of fluid being
measured. This includes calibration factor, compensation type,
compensation parameter, product type, valve settings, no flow
timeout and others. Refer to the operation manual supplied with the
register for instructions. Failure to properly calibrate and setup the
register can result in unexpected operation, inaccurate measurements and damage to equipment or property.

Navigation Keyboard Functions
Start/Enter Key

Power Light

Stop/Cancel Key

Arrow Keys
Power Light

Allows you to see that there is power to the electronic register.

Start/Enter Key

Allows you to enter register functions and start deliveries.

Stop/Cancel Key

Allows you to stop a delivery and cancel an operation.

Arrow Keys

Allow you to move to different fields on the Register.

5

Navigation Keyboard Functions (Continued)
Alpha, Numeric, and Symbol Keys

Preset Key

Print Key

Mode Key

Shift Key

Preset Key
Alpha/Numeric Keys
Mode Key
Print Key
Shift Key
Shift & Mode

Allows you to PRESET the Price and Tax as well as Gallons into the Register.
Allow you to enter different prices, products, etc. into the Register.
MODE allows you to select different screens on the Register.
Allows you to print. You can print the delivery with or without selecting the STOP key.
Allows you to select the Alpha Keys on the Alpha/Numeric Keys. Selecting Shift allows
you to use anything on the Key Pad in yellow.
Allows you to get into the main Menu screen.

Display Icons
ICON

DESCRIPTION
Printer with no ticket.

No printer connection
Printer ready with Ticket
Valve not open
Valve(s) open
System Settings
Weights & Measures

AIR

Air/Vapor Exhaust

6

Select Function

SELECT FUNCTION MENU (Quick Guide)
Start Delivery
Show Last Delivery
Begin or End Shift
Duplicate Shift Ticket
Re-Print Tickets
Non-Printed Delivery
Already Printed Delivery
Shift Tickets
System Menu
Reports
System Settings
W&M Settings
Product Settings
Advanced Functions

Begins delivery transaction.
Shows the last delivery on the TCS 3000 screen.
Beginning Shift will take a record of Delivery information at the start
through the end of the user shift.
Duplicate Shift Ticket will print a duplicate of the Begin or End Shift.
Will reprint past delivery transactions
Prints the last 75 transactions that have not printed.
Reprints the last ### of transactions already printed
Reprints the last ### of shift tickets.
Setup and Configuration MENU’S for TCS 3000
Calibration Log / Identification and Software Version
Configuration of System Parameters, Printer and Auxiliary Devices
Product Setup and Calibration
Product Activation, Price Settings and Device Time Settings
System Software Update

SELECT FUNCTION — Start Delivery
1) START DELIVERY. Press START to begin delivery transaction. This will reset the register causing the
delivery screen to read 0.0. Start your delivery.
2) If a Preset or Customer ID Field is Enabled, the delivery process will begin with prompts requesting data input.
See Page 14 for Preset Settings and / or for Customer ID Field to Enable/Disable.
3) If a Multiple Tank Delivery is Enabled, the Operating Driver must Hold the Shift Key down while pressing the
START key. When the Multiple Tank Delivery begins, a multiple tank icon will be
displayed during delivery. See Page14 for Multiple Tank Delivery to Enable/Disable.
4) Finish the delivery.

Press STOP once to PAUSE and twice to STOP. If the Printer is Enabled, the
ticket will be printed automatically. If the printer is not Enabled, it will be stored in memory
to be retrieved at a later date.

7

Select Function
—Show Last
SHOW LAST

Press START/ENTER to see the last delivery transaction

—Begin Shift/End Shift
The Shift function records the Time/Date, Meter Identification and the Delivery Data from the beginning of the shift to the
end of the shift. NOTE: This function is only accurate as the driver operators that utilize this feature.
1) BEGIN SHIFT
Press and hold the SHIFT key, then press the MODE key.
2) END SHIFT
Press and hold the SHIFT key, then press the MODE key.
3) After or before each Shift, the display will read Saving and Printing BEGIN or END Shift Ticket.

Sample Begin and End Shift Tickets

View Inventory
View Inventory allows you to select and view the inventory of product in the tank.
INVENTORY DISPLAY

Displays the inventory and tank size.

8

Select Function
SELECT INVENTORY

Allows you to use the arrow keys to select the product in order to view the Inventory
Details.

PRINT INVENTORY REPORT Generates a ticket of the Inventory Report

—Duplicate Shift Ticket
To print a Duplicate Shift Ticket, navigate down to select the function and press ENTER.

—Re-Print Tickets
To locate and reprint a past delivery ticket, navigate down to select the function and press ENTER
1) NON PRINTED DELIVERY

Will ask how many of the last sequential tickets (that have NOT printed) do you
wish to print. Enter quantity and press ENTER.

2) ALREADY PRINTED DELIVERY

Will ask how many of the last sequential tickets do you wish to re-print. Enter
quantity and press ENTER.

3) SHIFT TICKETS

Will ask how many of the last sequential tickets do you wish to re-print. Enter
quantity and press ENTER.

System Menu (Quick Guide)
Report

Show Prover Status
Prover Ticket
Meter Info
Version Info

View and print calibration, meter information and software
Weights & Measures access, calibration and configuration log
Print calibration proving ticket
Meter identification
Operating Firmware and Software

System Settings
Display Settings
Printer Settings
Regional Settings
Delivery Settings
Auxiliary Devices
Connectivity
Misc. Settings

Configuration of system functions
Configure display screens and fields
Select printer, host ,remote or none
Date and Time settings
Configure delivery functions like tickets, presets, ID fields, etc.
Select and configure auxiliary devices and pulse output
Configure register and printer addresses for network data sharing
Password settings

W&M Settings
Products
System Metrics
Temp Probe
Meter Information
Prover Ticket
Reset Totalizers
Enable Remote Config

Weights & Measures product setup and calibration
Product settings and calibration
Unit of measure precision
Temperature probe calibration
Register, Meter and Truck Identification
Print calibration proving ticket
Reset system and product totalizers
Remote interface configuration

Product Settings
Product Prices
Activate Product
Deactivate Product
Product Timing
Product Lists

Product identification for shifts and price/tax
Product pricing and taxation
Activating onboard products within Shifts
Deactivating onboard products outside of Shifts
Product preset and auxiliary device timing
Listing of active, inactive and uncalibrated products

Advanced Functions
System Shutdown
System Update

Administrative Configuration
Rebooting of system
Software update
9

System Menu
—Reports
1) SHOW PROVER STATUS
Selecting Show Prover Status allows you to view the last date and time of the last calibration.
2) PROVER TICKET
Selecting Prover Ticket allows you to print the prover information from the register.
3) METER INFO
Selecting Meter Information allows you to view the Meter Data, such as The Truck ID, Register ID, Meter Make, Meter
Model, Meter Version, and the Meter Serial Number. Information must be input within the Weights & Measures menu.
4) VERSION INFO
Selecting Version Info allows you to view the Version of Software and Firmware running on the TCS 3000.
5) MEMORY STATUS
Selecting Memory Status allows you to view the number and type of tickets printed by the TCS3000.

—System Settings
1) DISPLAY SETTINGS
DELIVERY SCREENS
Select Active Type
Configure Type 1
Configure Type 2
Configure Type 3

Active Type allows you to set your DEFAULT display screen. Highlight the type
(type 1, 2, or 3) of screen you would like to view during delivery and start-up.
Using the arrow keys to move around the screen, highlight the field you would like
to change and select ENTER. The field options are in Table 1 below.
Using the arrow keys to move around the screen, highlight the field you would like
to change and select ENTER. The field options are in Table 1 below.
Using the arrow keys to move around the screen, highlight the field you would like
to change and select ENTER. The field options are in Table 1 below.

Empty

No Data

Product Name

(LPG, Diesel, Av Gas, Etc.)

Delivery Gross

Non-Compensated Delivery Total

Delivery Net

Compensated Delivery Total

Delivery Volume

Amount of Delivery

Delivery Total

Total Delivered

Flowrate

Amount Delivered through Per Minute

AVG Temperature

Average Temperature of Product

Temperature

Temperature of Product

Mass

Mass of the Product (e.g. Pounds per Gallon, etc.)

Preset Remain

Remaining Preset (What is left of the Preset Total)

Preset Volume

Preset Volume Amount for Delivery

Preset Amount

Preset Currency Amount for Delivery

Density

Density of the Product

TABLE 1

10

System Menu
TYPE 1

TYPE 2

TYPE 3

TYPE 4

* TYPE 4 Only displays delivered volume.
CALIBRATION SCREEN
Temperature
Flowrate
Empty

Calibration screen will show volume/mass and Temperature
Calibration screen will show volume/mass and Flowrate
Calibration screen will show volume/mass and nothing else

BRIGHTNESS Brightness allows you to set the brightness of the display screen from 100 to 30 percent
(brightest to dimmest) settings.
NET TOTALIZER

Net Totalizer allows you to set whether the Net Totalizer is visible on the display screen.

Always
Auto

Net Totalizer is always visible
Net Totalizer is visible only when a product has Automatic Temperature Correction
(ATC) enabled on a Product
net Totalizer is never visible

Never

GROSS TOTALIZER Gross Totalizer allows you to set whether the Gross or Volume Totalizer is visible on the
display screen.
Volume Totalizer
Mass Totalizer

Volume Totalizer is always visible
Mass Totalizer is always visible

2) PRINTER SETTINGS
ENABLE/DISABLE PRINTER
Enable
Disable

Allows the printer to operate. Highlight Enable and select ENTER. When
the printer is Enabled, a printer icon will appear in the top left portion of the screen.
Will not allow the printer to operate. Highlight Disable and select ENTER. When
the printer is Disabled, the little printer will disappear in the top left portion of the
screen.

11

Weights & Measures
SELECT PRINTER
Epson TMU 220/295
Citizen CMP30
Printek
Blaster
Remote
None

Epson slip or roll printer driver installed
Citizen printer driver installed
Printek printer driver installed
Blaster printer driver installed
Selecting Remote will allow you to use a printer remotely when connected to the
register through a daisy chain RS485 serial communication.
Selecting None will remove the communication for printing

PRINTER HOST
Printer Host is used when you plan to daisy chain multiple TCS 3000 registers together for
a single printer. Host is the primary meter and the Clients are all registers following the
Host.
Enable/Disable Host

To Enable or Disable the Printer Host, highlight Enable or Disable and select
ENTER
- Enable will allow you to use Printer Host
- Disable will not allow you to use Printer Host

3) REGIONAL SETTINGS
DATE & TIME
Date Format

MMMM DD, yyyy
MM/dd/yyyy
yy/MM/dd
dd/mm/yyyy
dd/mm/yy

Time Format

24 Hour Clock
12 Hour Clock AM/PM

Set Date

Year — Format YYYY
Month — Select Month
Date — Select Date

Set Time

Format time as Hours (input from 24 hr. clock) . Minutes . Seconds (HH.MM.SS)
NOTE: a period must be used as your divider

DECIMAL SYMBOL

Select a ‘.’ period or a ‘,’ comma and press ENTER

4) DELIVERY SETTINGS
CONFIGURE TICKETS
Select Ticket Type

Sets the DEFAULT for the delivery ticket. Choose from the following:

CUSTOM1

Allows you to customize the ticket

MAXIMUM

Allows the maximum amount of space on the ticket.

MINIMUM

Allows the minimum amount of space to be used on the ticket.

ONELINER

CUSTOMIZE TICKET

Uses one line on the ticket.

Customize Ticket allows you to customize the preconfigured information printed
on the delivery ticket. Choose from the following:

12

System Menu
TCS 3000 Menu

Example Prints
Total Control Systems
TCS 3000
Delivery Ticket
(888) 888-8888
Programmable Field
———————————————Start Jun 04, 2012 09:42:09 AM
End Jun 04, 2012 09:53:42 AM
3842 Meter 2
########
Gasoline (Product setup in Prover)

Header 1
Header 2
Header 3
Header 4
Header 5
Thick Separator
Start Time
End Time
Truck ID
Ticket Number
Product Name
ProdNet Total Begin

########

ProdNet Totalizer

########

ProdGrs Total Begin

########

ProdGrs Totalizer

########

SysNet Total Begin

########

SysNet Totalizer
SysGrs Total. Begin
SysGrs Totalizer
Delivery Section
Customer ID 1
Customer ID 2
Customer ID 3
Customer ID 4
Line
Delivery Gross Begin
Delivery Gross End
Delivery Net Begin
Delivery Net End
TempComp Line
Tempcomp Table
Average Temp
Gross Delivered
Net Delivered
Line
Unit Price
Sale Amount
Tax 1
Tax 2
Tax Amount
Star Line
Amount Due
Empty Line
Thick Separator
System Line 1
System Line 2
Footer 1
Footer 2
Footer 3
Footer 4
Footer 5

########
########
########
—— Delivery ——
Programmable Field
Programmable Field
Programmable Field
Programmable Field
########
########
########
########
Volume Corrected to 60F (15C)
Table —— i.e. Table 24
AVG Temp. F
Gross Gal. Delivered
Net Gal. Delivered
Unit Price —- i.e. 1.86
########
Tax 1 —— i.e. Road Tax
Tax 2 —— i.e. Sales Tax
Tax Amount
***********
Amount Due ———— ##.##
########
————** Duplicate Invoice **
*** Power Loss ***
Programmable Field
Programmable Field
Programmable Field
Programmable Field
Programmable Field

13

System Menu
Add Ticket Type

Create a NEW Customized Ticket, then press ENTER to name it.
Copy from an Existing Ticket, then press ENTER to name it.
NOTE: Any new ticket name must be 3 or more characters long

Remove Ticket Type

Select ticket to be removed from the system and press ENTER

Header Defaults

There are FIVE programmable fields for contact information or messages

Footer Defaults

There are FIVE programmable fields for contact information or messages

Shift Ticket Headers

There are FOUR programmable fields for contact information or messages

Inventory Tickets Header

There are FOUR programmable fields for contact information or messages

PRESET SETTINGS
Enable Preset Utilizing the preset will request a preset amount before a delivery begins. After selection,
press ENTER to complete setting.
Enable Preset
Preset By Price
Gross Preset
Net Preset
Retain Preset

Enable or disable preset
Enable or disable preset by Price
Enable or disable preset in GROSS VOLUME
Enable or disable preset in NET CORRECTED VOLUME
Enable or disable preset for repeat BATCH presets

MULTIPLE DELIVERIES
Allows for the user to fill multiple tanks on one (1) single ticket transaction.
Simply press and hold the SHIFT key down while pressing the START key
to begin the multiple deliveries.
If preset is enabled, each tank delivery will prompt the preset amount.
CUSTOMER ID OPTIONS
The Customer ID Option will provide four (4) separate fields for the user to input prior to
the delivery. The Customer Identification is normally used for Tank, Truck, Airplane Tail
No., Locomotive, Driver, Customer, etc. Manual entry of data will be required through the
alpha-numeric keypad. After selection, press ENTER to complete setting.
Customer ID# (1-4)
Customer ID# Text
Field programmable for identification
Request ID#
Field requires user to enter an ID
Enforce ID#
Field requires user to enter an ID in order to operate the system
Validate ID#
Field validates the ID to ensure the ID is in the database, if invalid
the system will be inoperable
DISPLAY PRECISION
The unit precision can be displayed as a whole, tenth, hundredth or thousands measure
ment. After selection, press ENTER to complete setting.
1
1.1
1.11
1.111

Whole Unit
Tenth Unit
Hundredth Unit
Thousands Unit

14

Select Function
ZERO FLOW TIMEOUT
Feature will complete a delivery transaction if the user does not press the STOP key.
Enter whole numbers in Seconds for the timeout setting and press ENTER.
NOTE: Factory setting is 180 seconds, 3 minutes after the last pulse transmission to the TCS 3000 register. This feature CANNOT be disabled. For desired extended periods, utilizer a large number to have the
Timeout ignored.
PAUSE OPTIONS
Pause controls how pump control is used.
Allow Pause
Allow Pause Pauses the pump during the delivery
Pause Pump Pause Pump stops the delivery completely during delivery.
5) AUXILIARY DEVICES
EXTERNAL DISPLAY
The External Display setting is for the specific manufacturers of large LED displays. This
setting is for serial communication to an ancillary display that will read the same data that is
displayed on the TCS 3000 register.
Enable/Disable

Enable or disable and press ENTER

Configure

Select Type:
Address:
Display Data

Test

This is a test sequence of numbers to exhibit on external display

Red Lion LD is currently the only external display available today
Display Address from 1 to 99 and press ENTER
Choose the information to display on External Display and press
ENTER
- Delivery Gross
- Delivery Net
- Delivery Volume
- Delivery Total (Currency)
- Flow Rate
- Mass

AIR ELIMINATOR
The Air Eliminator is for the electronic actuation of a solenoid exhaust vent and a down
stream valve, when a level sensor switches.
AE Enable/Disable
AE Detection
AE Relay

Enable or disable for operation
Select Normally Open or Closed for level sensor detection
Enable or disable exhaust vent solenoid valve actuation

ADDITIVE INJECTOR
This feature is not currently enabled

15

Select Function
PULSE OUTPUT
The solid state pulse frequency transmission of a scalable pulse factor
Enable/Disable

Enable or disable operation

Configure

Sets the DEFAULT for pulse transmission output data
Delivery Total (Currency)
Gross Volume
1
1.1
1.11
1.111

(1 pulse per unit)
(10 pulses per unit)
(100 pulses per unit)
(1000 pulses per unit)

Net/Auto Volume
1
(1 pulse per unit)
1.1
(10 pulses per unit)
1.11
(100 pulses per unit)
1.111 (1000 pulses per unit)
Pulse Repeater repeats the incoming pulse value
Startup Reset

Enable or disable and press ENTER

RFID READER
RFID is for fixed location or fleet refueling
External
ThinkMagic

External is used for remote readers
ThinkMagic is for fixed locations

CONNECTIVITY
Connectivity is used for accessory communication settings
Network Settings
Interface
Address

Interface is for handheld communication. An interface is required for this setting.
Device Address will assign the TCS 3000 the unique address within the Daisy
Chain communication sequence. Primary Host will always be number one (1) and
the Client Address range will be two (2) through eight (8).

Printer Settings
Enable/Disable
Select Printer
Printer Host
Clients Address Range

Enable or Disable for operation
Select desired printer to be used with the system
Enable or Disable a printer host
Displays the range between Client and Host in a daisy chain.

MISC SETTINGS
L1 Password
Level one (1) password protection for System Settings.
Procedure to set L1 Password is as follows:
1.
2.
3.
4.

Highlight L1 Password and press ENTER.
Highlight Set Password and press ENTER.
Input alphanumeric password and press ENTER.
Confirm password entry by resubmitting password, and press ENTER.

NOTE: Alphanumeric password must be at least three (3) characters long.

16

Select Function
L2 Password
Level two (2) password protection for System Settings.
Procedure to set L2 Password is as follows:
1.
2.
3.
4.

Highlight L2 Password and press ENTER.
Highlight Set Password and press ENTER.
Input alphanumeric password and press ENTER.
Confirm password entry by resubmitting password, and press ENTER.

NOTE: Alphanumeric password must be at least three (3) characters long.
Access Key
Access Key is used to lock or unlock the register keyboard when a Computer or
Handheld device is in use.
System Mode
System Mode is used for databases
Default
MR1

Used for standard register mode
Used for database

User DB Update
Used to update the database.

Weights & Measures Settings
NOTE: The Calibration bolt must be removed in order to enter calibration mode. To remove the bolt, unscrew the bolt
with a 3mm Hex drive. Place calibration plate and screw in a safe location where it will not be lost. Under the calibration
plate you will find a screw. Using the 3mm Hex drive, loosen the calibration screw. You do not need to remove this
screw all the way.
*If you lose the calibration screw, you will not be able to operate the register.*
DO NOT LOSE THE SCREW
BEFORE YOU CALIBRATE THE REGISTER YOU MUST ENTER A PRODUCT
To Calibrate begin in section ADD NEW on Page 20.

*NOTE: ALL PRODUCTS MUST BE CALIBRATED INDIVIDUALLY *
PRODUCTS
PRODUCT TEST RUN This allows you to run the product after you’ve calibrated in order to verify repeatability.
Available Products

Highlight the product you are calibrating and select ENTER.
START automatically begins the product test run until you press STOP to
finish.

RECALIBRATE PRODUCT
Available Products

Highlight the product you want to re-calibrate and select ENTER.

*If you need to modify the settings you originally selected for the calibration of a product select MODIFY PARAMETERS,
if the settings were correct and you do not need to change them select BEGIN RECALIBRATION.*

17

Weights & Measures
A) Modify Parameters
Product Name

Using the keypad type in the name of the product you are calibrating. If
the product listed is correct select ENTER. To change the product name
press Enter and input name as desired.

Compensation Table

Choose the correct Volume Temperature Compensation Table and press
ENTER. See TABLE 2 for reference.

Comp. Table Param.

Input the correct Compensation Table Parameter and press ENTER. See
TABLE 2 for reference. NOTE: this list references most common products,
not an exhaustive list of every volume correction

Product Name

API Table

Temp.

Coefficient Value

Range

Mean

Fuel Oil

6B

Gasoline

6B

Diesel

6B

Kerosene

6B

Jet A

6B

Jet A-1

6B

Av Gas

6B

Refined Fuels

6B

F

Specific Gravity

0 — 85

Liquefied Propane Gas (LPG)

24

F

Specific Gravity

0.500 — 0.550

0.510

Gasoline

54B

C

Density KG/m3

640 — 780

730

Diesel Oil

54B

C

Density KG/m3

780 — 1074

840

Fuel Oil

54B

C

Density KG/m3

830 — 900

840

Kerosene / Jet Fuel

54B

C

Density KG/m3

780 — 840

800

Stoddard Solvent

54B

C

Density KG/m3

780 — 800

790

Lubricating Oils

54B

C

Density KG/m3

850 — 905

880

TABLE 2
18

Weights & Measures
Mass Density

To provide a calculated Mass value, determine the value to input Mass
Density and press ENTER.
Mass = Density X Volume
Unit of Measure
Gram/cm3

Gram/Cubic Centimeter

Gram/m3

Gram/Cubic Meter

Kilogram/m3

Kilogram/Cubic Meter

Milligram/m3

Milligram/Cubic Meter

Pound/ft3

Pound/Cubic Foot

Pound/in3

Pound/Cubic Inch

Ton/yard3

Ton/Cubic Yard

Pump Control & Timing Enable/Disable Pump Control and select ENTER.
- Pump is an Optional Output Control
- Enabled means that the pump control will energize whatever element of
the truck you’ve connected to.
- Disabled means that the pump control is not active and will not energize.
Pump Starter to enter the Start Duration time in seconds, then press
ENTER.
Pump Starter Advance to enter Starter Advance time in Seconds, then
press ENTER.
Pump Stabilization is used to enter how long you wish the Pump Starter
stays powered. Enter value in Seconds and press ENTER.
Valve Type
Select whether you are using a Single or Dual Stage Valve and press
ENTER
- A Single Stage valve will energize valve with Solenoid 1.
- A Dual Stage valve will energize valve with Solenoids 1 and 2.
DUAL
-1101
Both S1 and S2 energize at the beginning of delivery and near the end of the delivery
S1 shuts off and S2 is still operating.
-1001
At the beginning of the delivery the S1 valve opens energizes while the S2 remains
closed until near the end of the delivery, then S1 closes and S2 opens.

19

Weights & Measures
Maximum Flowrate

Input the maximum rated flow of flow meter and press ENTER.
NOTE: this value is critical to the Valve actuation!

Pulser Type

Select the pulse input type (Single or Dual Channel) and press ENTER.

Pulser Estimate

Manual entry of the Meter Pulse Estimate (Meter Factor). Input pulse
value and press ENTER.

Product Units

Select TCS 3000 register units of measure and press ENTER.
Volume: Highlight Volume Unit and press ENTER.
GAL
L
UKG
daL
mL
m3
bbl

USA Gallons
Liters
UK Gallons
Dekaliter
Milliliter
Cubic Meter
Barrel

NOTE: Selecting Product Unit does not change the Totalizer unit of
measure. See Page 21 for changing Totalizer unit of measure.
Temperature: Highlight Temperature Unit and press ENTER
F

Fahrenheit

C

Celsius

K

Kelvin

Currency: Select the Currency Symbol or Abbreviation and press ENTER.
SYMBOL

ABBREVIATION

$

Dollar

USD

£

Pound

EUR

Euro

¥

Euro

GBP

British Pound Sterling

CAD

Canadian Dollar

MXN

Mexican Peso

CLP

Chilean Peso

JPY

Japanese Yen

BGN

Bulgarian Lev

CHF

Swiss Franc

CZK
DKK

Czech Republic Koruna
Danish Krone

HUF

Hungarian Forint

LVL

Latvian Lats

LTL

Lithuanian Litas

PLN

Polish Zloty

RON

Romanian Leu

SEK

Swedish Krona

20

US Dollar

Weights & Measures
Mass: Highlight the Mass unit and press ENTER.
lbs

Pounds

oz

Ounce

t

Ton

kg

Kilogram

g

Gram

Hose Volume: Enter unit value for “packing” hose downstream of meter
and press
ENTER. Value will not display prior to setting and there will be no lost liquid.
B) Begin Recalibration
*NOTE: ALL PRODUCTS MUST BE CALIBRATED INDIVIDUALLY *
Select Begin Recalibration to change the Meter Calibration Value. Press ENTER
to begin calibration run. The display will prompt you to press START to begin
automatic calibration of the flow meter. Press STOP when finished with a certified
Weights & Measures volumetric or gravimetric proving system. Input Prover Value
and press ENTER.
When finished, a Calibration Summary screen will appear with the Gross Amount,
Net Amount, Average Temperature, Compensation Table, Pulse/Second and
Pulse/Volume (Meter Calibration Value). Press STOP to continue.
Display menu will prompt you to continue with a Test Run? or to finish the
calibration. Push SHIFT + START to begin Test Run to validate the Meter
Calibration Value. Press STOP to finish.
C) Edit Prod. Calibration
Allows a manual calibration modification. A “WARNING” screen will then be
displayed, press ENTER to continue to change Meter Calibration Value.
- Select Product to manually change Meter Calibration Value. Adjust the current
Meter Calibration Value by multiplying by the equation below.
- Input value and press ENTER, which will display a “MODIFICATION” screen.
Press any key to continue.

% ERROR =

Volume on Prover — Volume on Meter Display

X 100

Volume on Meter Display
D) Add New
Before you can calibrate the register, you must enter a product. Select Add New
and use the keypad to enter a product (e.g. LPG, Fuel Oil, Aviation Gasoline, etc.).
Once you’ve entered your product, press ENTER.
- All parameters for a New Product MUST be entered for the product to be
accepted by the TCS 3000. Follow pages 17 through 19, under Modify Parame
ters to complete the Add New product setup. Once the new product parameters
have been entered, you will be required to calibrate the product. NOTE: A new
product MUST be calibrated for it to be available as an Active product. Without
calibration, the new product will only be seen in Product Settings LIST.
21

Weights & Measures
E) Remove Product
To remove an unwanted product from the TCS 3000, select and press ENTER.
To confirm product removal, press MODE. NOTE: You must first End Shift and
then Deactivate the product under Product Settings.
2) ACCOUNTING
Select Accounting to set the Ticket Number.
SYSTEM METRICS
PRECISION
1
1.1
1.11
1.111

The unit precision can be displayed as a whole, tenth, hundredth or thousands measurement.
After selection, press ENTER to complete setting.
Whole Unit
Tenth Unit
Hundredth Unit
Thousands Unit

SYSTEM TOTALIZERS
This function will allow the System Totalizers to be changed to zero (0). Press ENTER to
proceed with change.
Volume Unit

Once the Totalizer has been changed, the display will prompt you to
change the Unit of Measure for the Totalizer. Highlight the Unit of Measure and press
ENTER.
GAL

USA Gallons

L

4) TEMP PROBE

Liters

UKG

UK Gallons

daL

Dekaliter

mL

Milliliter

m3

Cubic Meter

bbl

Barrel

This function is used to change the reference temperature of the meter system RTD
temperature probe. Highlight Offset Calibration and press ENTER.
Highlight Reference Temperature Unit of Measure and press ENTER.
F

Fahrenheit

C

Celsius

K

Kelvin

Enter the correct temperature to recalibrate the Reference Temperature and press ENTER.
5) METER INFORMATION
Selecting Meter Information allows you to enter the information off of your meter and
register. This information is required for the Report Menu on page 10, as well as the
Prover Tickets from Meter Calibration.

22

Weights & Measures
REGISTER #

Highlight Register # and input the TCS 3000 serial number located on the unit. Press
ENTER when complete.

TRUCK ID

Highlight Truck ID to input the truck or tank number. Press ENTER when complete.
NOTE: if there are multiple meters daisy chained together, the Truck ID and Meter
sequence number should be input here.

METER VERSION

Highlight Meter Version and enter the manufacture. Press ENTER when complete.

METER MAKE

Highlight Meter Make and enter the meter manufacturer’s name and Press ENTER
when complete.

METER MODEL

Highlight Meter Model and enter the assembly model number. Press ENTER when
complete.

METER SERIAL #

Highlight Meter Serial # and input the meter serial number of the unit. Press ENTER when
complete.

SYSTEM ID

Highlight System ID and input the system identification. Press ENTER when complete.

6) PROVER TICKET
Selecting Prover Ticket allows you to Print the existing Prover Data from the TCS 3000.
Select PRINT to print the Prover Ticket.
7) TICKETS CLEANUP
Enabling Tickets Cleanup will allow the system to delete the oldest 500 non-printed tickets
when there are more than 5000 non-printed tickets stored.
*This Might Not Be Legal in Some Countries or States
8) RESET TOTALISERS
System and Product Totalizers record the amount of all liquid that has passed
through the meter by product.
* Please Note *
Resetting the Totalizers will reset the TCS 3000 Totalizers to zero. There is no way to recover totalizers once
deleted.
SYSTEM TOTALIZER
System Totalizers record the amount of all liquid that has been measured.
End Shift before resetting the System Totalizer. Highlight the System Totalizer and press
ENTER. A “WARNING” will appear on the screen that you are about to reset the
Totalizers. Press MODE to confirm the Totalizer reset.
PRODUCT TOTALIZER
Product Totalizers record the amount of liquid for a specific product that has been measured.
You must End Shift and Deactivate Product in Product Settings (page 22) before resetting
the Product Totalizer. Without doing so, the error “No Active Products” will be displayed.
Highlight Product Totalizer and press ENTER.
9) ENABLE REMOTE CONFIG
Allows you to connect the TCS 3000 to a F-RAMS handheld device to remotely
control the Calibration of the register.
- To Enable Remote Config make sure your F-Rams handheld is connected to the TCS
3000 register with the TCS 300859 quick disconnect cable kit).
- Highlight Remote Config and select ENTER. This will enable the Remote Config setting
and you will be able to calibrate your system.
- When finished calibrating, press any key to exit.

23

Select Function
—Product Settings
1) INVENTORY
Inventory monitors how much product is in a tank.
ADD INVENTORY
Creates an Inventory “Tank” to be monitored. Here you will Name your Inventory “Tank” Enter in the Tank
Capacity and Enter the Current Tank Level
**Must be outside of a Shift to do this step**
ASSIGN INVENTORY
Allows you to Pair an Active Product to the Inventory Tank Created to be Monitored.
**This must be done to track inventory levels**
**Can be done during a Shift**
UPDATE INVENTORY
Allows you to correct the Inventory levels by manual entering the proper inventory level.





Add to Inventory allows you to add to the current inventory when you are loading “X” amount of product to the tank
Set Inventory Value allows you to change the inventory level to a specific amount
Filling up the inventory to 100% Tank Capacity
Emptying the Inventory to 0%.
**Can be done during a Shift**
VIEW INVENTORY
Allows you to see your total inventory levels of numerous tanks on one display, See Individual inventory
details, or print an Inventory Report
**Can be done during a Shift**
REMOVE INVENTORY
Removes the Inventory Tank from being Monitored
**Must be outside of a Shift to do this step**
Shortcut to Inventory options from Delivery Screen
Pressing Shift + Print will allow you to Update, Fill, or Empty Inventory Levels Quickly during a Shift
After Adjusting the inventory you will be prompted to provide a Bill of Lading Number

2) PRODUCT PRICES
Product Prices allows the price to be set for a specific product. For multiple products,
pricing must also be changed. To set pricing, highlight the desired product and press
ENTER. NOTE: if you have not changed the Product name, the factory default “DEMO” will
be displayed.

24

Select Function
UNIT PRICE

Highlight Unit Price and press ENTER. Input the price value and press ENTER.

TAX 1 NAME

Highlight Tax 1 Name and press ENTER. Input tax name and press ENTER.

TAX 1 TYPE

Highlight Tax 1 Type and press ENTER. Use the navigation arrows to select Tax 1 Type
and press ENTER.

TAX 1 VALUE

Highlight Tax 1 Value and press ENTER. Input tax value and press ENTER.
None
No tax will be entered.
Percent

Tax amount value is calculated as a percent (%).

Per unit

Tax is calculated per unit of measure.

TaxTax

Tax is calculated on a tax.

TAX 2 NAME

Highlight Tax 2 Name and press ENTER. Input tax name and press ENTER.

TAX 2 TYPE

Highlight Tax 2 Type and press ENTER. Use the navigation arrows to select Tax 2 Type
and press ENTER.

TAX 2 VALUE

Highlight Tax 2 Value and press ENTER. Input tax value and press ENTER.

None

No tax will be entered.

Percent

Tax amount value is calculated as a percent (%).

Per unit

Tax is calculated per unit of measure.

TaxTax

Tax is calculated on a tax.

CURRENCY

Select the Currency Symbol or Abbreviation and press ENTER
SYMBOL
$

Dollar

USD

ABBREVIATION
US Dollar

£

Pound

EUR

Euro

¥

Euro

GBP

British Pound Sterling

CAD

Canadian Dollar

MXN

Mexican Peso

CLP

Chilean Peso

JPY

Japanese Yen

BGN

Bulgarian Lev

CHF

Swiss Franc

CZK

Czech Republic Koruna

DKK

Danish Krone

HUF

Hungarian Forint

LVL

Latvian Lats

LTL

Lithuanian Litas

PLN

Polish Zloty

RON

Romanian Leu

SEK

Swedish Krona

25

Select Function
PREVIEW PRICING
Preview Pricing will show the Product price and taxes.
3) ACTIVATE PRODUCT
Activate Product allows you to activate a product for a specific Shift. When liquid in your
tank changes, you can change the product and calibration to match.
- To Activate a product, highlight the product and press ENTER.
4) DEACTIVATE PRODUCT
Deactivate Product allows you to deactivate an active Shift product. When liquid in
your tank changes, you can also change the product.
5) PRODUCT TIMING
Product Timing allows auxiliary device settings to be changed to suite the needs of the
application. Currently set up for Preset Valve, Air Eliminator Hold and Hose Volume.
Product Timing is product specific, adjusting the actuation or closure type.
PRESET TIMING
Preset Timing adjusts the valve closure type for preset or security valves.
Highlight the Preset Timing function desired and press ENTER. This will be chosen as your
default setting for the specific Product.
Full-Auto

Full Automatic tune preset shutoff for Solenoid S1 (fast) and S2 (slow) flow valves.

Semi-Auto

Semi-Automatic tune preset shutoff for Solenoid S2 (slow) flow valve. Highlight Semi Auto
and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.

Next Fix

Next Fix is an automatic tune shutoff, however it will allow the preset to overrun batch
amount. Designed to automatically correct the shutoff on the next preset delivery. Highlight
Next Fix and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.

Static

Static settings for the Solenoid S1 (fast) and S2 (slow) flow valves. There is no automatic
correction for zero point shutoff. Highlight Static and press ENTER. Input Solenoid S1
(fast) flow valve closure and Solenoid S2 (slow) flow valve and press ENTER.

AIR ELIMINATOR HOLD
When the TCS 3000 senses air, it will actuate the Solenoid S1 and S2 to shut off and
open the Auxiliary Relay for the exhaust port to remove air from the system. Highlight Air
Eliminator Hold and press Enter. The HOLD (s) is the adjustable setting for the Auxiliary
Relay closure in Seconds. Input value in Seconds and press ENTER.
STARTUP VOLUME
6) PROUCT LISTS
Displays a list of Active, Inactive and Un-Calibrated products on the TCS 3000. To view
these Products, highlight the selection and press ENTER.

26

Select Function
—Advanced Functions
LOCK THE SYSTEM
SYSTEM SHUTDOWN
System Shutdown Shuts the TCS3000 down. You must cut power to the TCS 3000 and
reboot to turn the unit back on.
SYSTEM UPDATE
System Update allows you to upgrade the TCS 3000 Software. NOTE: Update process
does NOT change Weights & Measures settings or parameters.
Procedure to upload new software is as follows:
1)

Load new software upgrade to a USB thumb drive (dongle).
NOTE: The new software upgrade should be the ONLY file on the drive.

2)

Open the TCS 3000 register. On the front cover of the register, there are 2 mini-USB
connections.. Using a factory supplied USB cable, attach the thumb drive to the USB
port closest to the inside of the register. This port is the highest on the circuit board of the two.
See Figure 1.

3)

Plug the USB cable into the USB port, and then insert the USB thumb drive into the mating cable
(see Figure 1).

4)

Under Advanced Functions, locate System Update and press ENTER.

5)

The screen will display System Update, press MODE to continue with the update.

6)

If the thumb drive is not recognized or there is a faulty cable, the display will respond with NO
UPDATE DATA error message.

7)

Once the file is recognized, the operating system will begin the update process. This should
take approximately 4 minutes.
NOTE: Do not power down or pull USB thumb drive until the TCS3000 tells you to do so.

8)

You may remove the USB cable and close the TCS 3000 register once the Update is Complete.
FIGURE 1

Mini USB Port

Male Mini USB to
Female USB

USB Thumb Drive with
communication LED

27

“Must Know” & How To
Installation Procedure—Daisy Chain

Daisy Chain:
Daisy Chain is used for linking multiple registers together to use one printer or to link multiple registers to the database.

To Daisy Chain the Registers use a two wire 22 gauge shielded cable. Nominate one Register to be the Host.
Once you’ve chosen which Register will be the Host the other Registers will be considered the clients. Strip a small
amount of wire and run the wire from slot A and B of DAISY CHAIN on the Host Unit to slot A and B of DAISY CHAIN on
the Client Unit.
To tie the Client to the next Client unit on the Daisy Chain, strip a small amount of wire and run the wire from slot A
and B of DAISY CHAIN to slot A and B of the next client’s DAISY CHAIN.

B
A

B
A

Host
The Host will have 2 wires.

B
A

Client 2
Client 2 will have 4 wires.

B
A

Client 3
Client 3 will have 4 wires.

Client 4
The Last Client will have 2 wires.

B

B

B

B

A

A

A

A

Continue to Daisy Chain until you have tied the chain together, alternating slots on the Daisy Chain until you’ve
reached the end of the chain. The Host and the last Client on the chain will be the only two registers on the chain to
have a one wire connection.
28

“Must Know” & How To
Daisy Chain for the Printer
Connect the Printer to the Host Register. To set the Host :
Enable the Printer:
SYSTEM MENU → SYSTEM SETTINGS → PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER
Select the Printer:
PRINTER SETTINGS → SELECT PRINTER → [SELECTED PRINTER] → ENABLE
Selecting the Host Register

Select Register as Host:
PRINTER SETTINGS → DISABLE/ENABLE HOST → ENABLE
Select the Client Range:
PRINTER SETTINGS → PRINTER HOST → CLIENTS ADDRESS RANGE → CLIENTS RANGE START ADDRESS [ Enter 2 and
Select] →
CLIENTS RANGE END ADDRESS [ Enter the number of Registers on the Chain and Select]
*Please Note the Host is always # 1. The Client always starts at #2*
Selecting the Client Register
*If you are not using the Daisy Chain for the Printer Please Disregard the Enabling and Selecting the Printer Steps.
Enable the Printer:*
PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER
Select the Printer:*
PRINTER SETTINGS → SELECT PRINTER → [REMOTE] → ENABLE
SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → ADDRESS → DEVICE ADDRESS [Select the
number of the unit you are using ex. 2 if it is the second register on the chain or 3 if it’s the third register on the chain.]
To Connect to the Chain:
SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → INTERFACE BRIDGE [Only used when there
are 2 Registers tied in the chain] → TRANSFER DATA BETWEEN RS232 <-> RS485 INTERFACES ENABLED
Continue the Selecting Client Register steps for every Client on the Chain.

You may only use the Daisy Chain on five devices at a time. You may not Chain more than five devices together.
29

“Must Know” & How To
Installation Procedure—Daisy Chain Modem

Daisy Chain:
Daisy Chain is used for linking multiple registers together to use one printer or to link multiple registers to the database.

To Daisy Chain the Registers use a two wire 22 gauge shielded cable. Nominate one Register to be the Host.
Once you’ve chosen which Register will be the Host the other Registers will be considered the clients. Strip a small
amount of wire and run the wire from slot A and B of DAISY CHAIN on the Host Unit to slot A and B of DAISY CHAIN on
the Client Unit.
To tie the Client to the next Client unit on the Daisy Chain, strip a small amount of wire and run the wire from slot A
and B of DAISY CHAIN to slot A and B of the next client’s DAISY CHAIN.

B
A

B
A

Host
The Host will have 2 wires.

B
A

Client 2
Client 2 will have 4 wires.

B
A

Client 3
Client 3 will have 4 wires.

Client 4
The Last Client will have 2 wires.

B

B

B

B

A

A

A

A

Continue to Daisy Chain until you have tied the chain together, alternating slots on the Daisy Chain until you’ve
reached the end of the chain. The Host and the last Client on the chain will be the only two registers on the chain to
have a one wire connection.
30

Selecting the Host Register
Select Register as Host:
PRINTER SETTINGS → DISABLE/ENABLE HOST → ENABLE
Select the Client Range:
PRINTER SETTINGS → PRINTER HOST → CLIENTS ADDRESS RANGE → CLIENTS RANGE START ADDRESS [ Enter 2 and
Select] →
CLIENTS RANGE END ADDRESS [ Enter the number of Registers on the Chain and Select]
*Please Note the Host is always # 1. The Client always starts at #2*
Selecting the Client Register
Enable the Printer:*
PRINTER SETTINGS → ENABLE/DISABLE PRINTER → ENABLE PRINTER
Select the Printer:*
PRINTER SETTINGS → SELECT PRINTER → [REMOTE] → ENABLE
SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → ADDRESS → DEVICE ADDRESS [Select the
number of the unit you are using ex. 2 if it is the second register on the chain or 3 if it’s the third register on the chain.]
To Connect to the Chain:
SYSTEM SETTINGS → CONNECTIVITY SETTINGS → NETWORK SETTINGS → INTERFACE BRIDGE [Only used when there
are 2 Registers tied in the chain] → TRANSFER DATA BETWEEN RS232 <-> RS485 INTERFACES ENABLED
Continue the Selecting Client Register steps for every Client on the Chain.

You may only use the Daisy Chain on five devices at a time. You may not Chain more than five devices together.

31

Real Time Inventory How To

Manual Inventory How To

*Please note, you must End Shift before you may Add or Remove Inventory*
Real Time Inventory is for Automatic Tank Levels Only

Add Inventory:

Add Inventory:

While holding Shift select Mode → System Menu → Product
Settings → Inventory → Add Inventory →GIVE INVENTORY
NAME (Use the Keypad to assign a name, ex. Av Gas, Gasoline,
etc.) → Select Unit Volume (Gallons, Liters) → ENTER CAPACITY
(Tank Size) → ENTER INVENTORY (Actual Known Inventory) →
Press Any Key to Continue

While holding Shift select Mode → System Menu → Product
Settings → Inventory → Add Inventory →GIVE INVENTORY
NAME (Use the Keypad to assign a name, ex. Av Gas, Gasoline,
Tank 1, Tank 2, etc.) → Select Unit Volume (Gallons, Liters) →
ENTER CAPACITY (Tank Size) → ENTER INVENTORY (Actual
Known Inventory) → Press Any Key to Continue

Assign Inventory:

Assign Inventory:

Assign Inventory → Select an Active Product → Assign the Active Product to an Inventory List → Press Any Key to Continue

Assign Inventory → Select an Active Product → Assign the
Active Product to an Inventory List → Press Any Key to Continue

*Please Note You can apply multiple inventories to one meter.*

*Please Note You can apply multiple inventories to one meter.*

Update Inventory:

Update Inventory:

Update Inventory → ADD To Inventory → ENTER AMOUNT
(Amount added to tank)

Update Inventory → Level Meter → Select CH# (Ex. If Product
1 is tied to CH2, then you select LVL2) →

Set Inventory Value → ENTER CURRENT VALUE (Current
amount of product in the tank)

Inventory Update Message → Press Any Key to Continue
Fill Up Inventory → Press Any Key to Continue (Resets
Inventory to full capacity)

*Please Note: Use CH2-6*

Empty Inventory → Press Any Key to Continue (Zero’s out tank
amount)

*Also Note: Level Meter will only update when there is no
movement.*

To Check the Changes:

Remove Inventory:

Update Inventory → Level Meter →The LVL# you selected
should be highlighted.

Remove Inventory → Select Inventory → Press Mode to Confirm

*If you enter into this screen and None is highlighted, then the
unit does not see the circuit board or the Madison Gauge.

Print Inventory Report:
View Inventory → Print Inventory Report

A ticket will generate if a printer is set up.

Bill of Lading:

Remove Inventory:

Once you have finished in Inventory, select STOP/CANCEL →
Remove Inventory → Select Inventory → Press Mode to Confirm

ENTER BILL Nr. → START/ENTER

Print Inventory Report:

Inventory Short Cut

View Inventory → Print Inventory Report

In the Delivery Screen:
Hold down SHIFT and select PRINT (while holding Shift)

Bill of Lading:

You can enter inventory through the short cut only after you’ve
set up and assigned inventory.

Once you have finished in Inventory, select STOP/CANCEL →
ENTER BILL Nr. → START/ENTER

Color Guide:

Blue: Operating Volume

Yellow: 25% Cautionary Volume
32

Red: 10% Low Volume

“Must Know” & How To
TEMPERATURE PROBE CALIBRATION HOW TO
* The following is based on product(s) you have calibrated. You must select the compensation table and the temperature unit for
the product when Calibrating your product in order to Calibrate Temperature.*
Press Shift and Mode to enter the Select Function
Screen.
Use the arrow keys to highlight SYSTEM MENU and
Select START/ENTER.
*Remove the Calibration Bolt and set in a safe location.*

*Note: You will want to take 3 temperature readings during a
run to get the average temperature.

Use the arrow keys to highlight W&M SETTING.
Select START/ENTER.
Use the arrow keys to highlight your product. Select
START/ENTER.
Use the arrow keys to highlight PRODUCT TEST RUN.
Select START/ENTER.
Use the arrow keys to highlight your product. Select
START/ENTER.

Enter the Average Temperature Select START/ENTER
*Note: The register will display that it is calibrating and is applying the corrections. It will take a minute to calibrate the RTD
Probe to the Weights & Measures Probe.
When Calibration is done the Register will display the following
message:

Use the arrow keys to highlight TEMP PROBE select
START/ENTER.

Repeat the steps if necessary.
Selecting TEMP PROBE will take you to Offset Calibration
Press START/ENTER
(You are now calibrating the TCS3000 Register Temperature
Probe to the Weights and Measures Temperature Probe)
Use the arrow keys to highlight the Reference Temperature
select START/ENTER.

33

Trouble Shooting
Trouble Shooting
To comply with Weights & Measures requirements, it is necessary to start and stop each delivery with a fully packed
hose. Normally, this will be the case. However, there are times where the hose is not fully packed (e.g. after a preset
delivery). As such, the hose must be packed and the register zeroed prior to making the next deliver.
NOTE: This procedure will not work for an empty or dry hose. If more than 1 gallon or 5
Liters of liquid is required to pack the hose, a delivery ticket must be printed.
To pack the hose at the start of a delivery:
Press the Start Button, this energizes the solenoids. Allow the pump to pack the hose.
TCS 3000 Trouble Shooting Guide
The TCS3000 troubleshooting guide covers most common problem situations. Call your Total Controls Service Center
for any problems that are not covered in this guide.
NOTICE

DANGER

It may be necessary to break Weights & Measure seals to
perform certain troubleshooting steps in this guide. Contact your supervisor or local Weights & Measures authorities for information before breaking any seals.

Serious Injury or Death may Result – Fire, Explosion, and
Electrical Shock Hazard.

Only trained and authorized personnel should perform
troubleshooting. Use extreme caution when troubleshooting and taking all electrical measurements. Be sure that
equipment is in a well ventilated area and that hazardous
or flammable vapors are not and will not be present during testing. If equipment is located in a hazardous environment, it may be necessary to remove the equipment
and perform troubleshooting in a safe area.

Trouble Shooting Guidelines:
1) Before attempting to troubleshoot the TCS 3000 system, become familiar with the operation and set-up of the specific
installation.
2) Make sure all electrical connections are secure and tight.
3) Make sure all terminal blocks are firmly connected.
4) ALWAYS use a good digital multimeter. Voltage levels are critical to proper system operation. Use an accurate,
reliable multimeter to test for proper voltages at the start of any service procedure. Voltage requirements are listed
under each component.
NOTE: Check for proper operating voltages before changing the circuit board. If the circuit board needs to be
changed, be sure to remove all power to the TCS 3000.
5) If an error occurs during a delivery, the message will appear on the Display and print on the delivery ticket. The
delivery ticket will print an error message that can be useful in troubleshooting. This ticket will automatically print.
Examine the prover ticket to make sure all set-up fields are accurate, e.g. pulses per unit volume, temperature
coefficient, and base temperature.
6) NEVER remove a terminal block or jumper with the power on.
7) NEVER install a terminal block or jumper with the power on.

34

Trouble Shooting
8) NEVER force a terminal block into its location.
9) NEVER exchange or reposition terminal blocks on the circuit board.
10) In case of a major problem such as a burned or water-damaged circuit board, evaluate possible causes before
replacing it and turn the power back on.
11) Isolate the problem before changing the circuit board.
12) Return faulty circuit boards with the proper forms, concisely completed.
There may be several probable causes for a system malfunction. Listed on the next 3 pages are several probable causes to aid in returning the system to operation as quickly as possible. The list is not all-inclusive and should only be used
as a guide.
PROBLEM

PROBABLE CAUSE

SOLUTION

Unit will not
power up or
there is no
display

Inadequate supply
voltage. +9 to 28
VDC is required for
operation

1. With the key in the accessory position, check the battery voltage to the circuit
board. Use the negative terminal as DC ground. While the TCS 3000 will
power-up at +9VDC, it is recommended that the input be at least +12.6VDC.
2. Check the 7.5A, in-line fuse for continuity. It is located in the accessory power
line. Replace if necessary.
3. If the green light blinks fast it is doing what it is supposed to, but then it will go
to a slow blink. If you see red, then you do not have enough power on the
register. It must see a minimum of 9vdc.
4. If the red light comes on and the unit doesn’t power-up. Check the voltage if
the voltage is OK but the temperature is -20 this will indicate that the heater is
warming the display to prevent any damage to the VGA display and should
come-up shortly

Unit blow
7.5A Fuse

+12 VDC battery line
is shorted to ground

1. For safety reasons, remove the 7.5A, in-line fuse from the accessory power
cable.
2. Unscrew the 3 pin power connector. Inspect for stray wire strands and
visible shorts.
3. Inspect the full length of the power cable. Look for damaged insulation, which
may cause shorting between the cable and ground potential (e.g. truck frame
or chassis). If the power cable is damaged, it must be replaced.
4. Replace the 7.5A fuse and re-install the wires into the terminal connector.
5. If the 7.5A blows again, then replace the power cable.
6. If the 7.5A fuse blows after replacing the power cable, then replace the TCS
3000 terminal circuit board.

35

Trouble Shooting
PROBLEM

PROBABLE CAUSE

SOLUTION

Power Failure appears
on the delivery ticket

Power to the TCS
1. Check accessory power cable for damage. Ensure that the power, common
3000 interrupted durand ground wires on power connector are secure. Located on the right hand
ing delivery.
corner of the terminal board
2. Turn on all truck accessories (headlamps, 2 way radio, heater, etc.). Engage
the hose reel and monitor the DV voltage at ## using terminal ## as positive
Static Discharge
and terminal ## as ground. If the voltage drops below +10VDC, the truck
electrical system may not be adequate to handle the current load for the TCS
3000. It may be necessary to upgrade the electrical system to accommodate
the 3-amp TCS 3000 current requirements.
3. Verify proper grounding of the TCS 3000. Refer to the TCS 3000 Installation
Manual for proper grounding procedures.

Epson printer Low voltage to the
release light Epson Printer
flashes

1. Check the battery voltage for a minimum of +12.6VDC.
2. Under extreme cold conditions, the printer may not operate. Warm up the cab
of the vehicle.
3. If the release light continues to flash, replace the Epson 295 Printer.

No power
indicator
lights to the
Epson Printer

No power to the Epson printer

1. Verify that the power switch is in the ON position. This switch is located on
the left-hand side of the Epson 295 Printer.
2. Check the printer power cable to ensure that it is seated properly. If the problem persists, replace the power cable followed by the Epson printer.

“Temperatur
e Error” appears on the
TCS 3000
display

Open or shorted circuit between RTD
probe and the TCS
3000

1. Check the RTD Probe and terminal block for continuity.
2. Remove terminal block Temp Probe from the circuit board. On the terminal
block, measure and record the resistance between the following pins:
PIN READING
Red to White 100 Ω ±20?
3. If the readings are not within the above tolerances, replace the RTD
probe.

Product flow Pulser shaft is not
does not reg- turning with product
ister on TCS flow. Pulse Failure
3000
Pulser Failure, register
is not reading
gallons or
liters

1. Manually spin the pulser shaft and monitor the TCS 3000 display.
2. If the TCS 3000 displays counter increments, this may indicate a mechanical
problem. Contact your TCS 3000 Service Center for assistance.
3. If the TCS 3000 display counter does not increment, see Pulser Failure.

Missing pulse
1. Check the pulser output.
counts.
2. Open the TCS 3000 cover by loosening the two bolts that hold the cover
Excessive reversals
closed. Using a reliable multimeter, measure the following DC voltages on
terminal block is connected to the circuit board. Use terminal as ground referNote: Pulser faults
ence.
generally occur in a
high vibration envi3. TERMINAL PULSER VOLTAGE
ronment. TCS is not
+0 VDC
responsible for puls+5 VDC
er failures caused by
+3.74 TO 0 VDC TAHA1 WHILE SPININING
excessive vibration.
+0 TO 3.74 VDC TAHB1 WHILE SPINNING
4 If the following voltages are observed, check for loose pulser wiring connections. If no loose connections are found, replace the encoder.
5 Insert a ticket into the Epson printer. Begin a delivery. With product flowing
through the meter, measure the following DC voltages on the terminal block.
6 TERMINAL PULSER VOLTAGE
+0 VDC
+5 VDC
+3.74 to 0 VDC TAHA1 WHILE SPINNING
+0 to 3.74 VDC TAHB1 WHILE SPINNING

36

Trouble Shooting
PROBLEM

PROBABLE CAUSE

SOLUTION

Valve will not
open

Solenoids are inac1. Insert a delivery ticket into the Epson printer and start a delivery.
tive or inoperative.
2. Start a delivery and listen for the audible clicking sound from the solenoids.
Foreign debris in sys- 3. If there is NO audible click form the solenoid, check the voltage to Pin +
tem
and 0 V of terminal block Solenoid 1. While the TCS 3000 is still in delivery, use a reliable multimeter to measure the following DC voltages on the
circuit board. Use 0 pin as a ground or frame ground.
4. If there is an audible click from the solenoid (but still no flow), this may be
an indication of a mechanical problem with the main valve or its associate
components. Contact your TCS3000 Service Center.
TERMINAL SOLENOID 1 for 2 VOLTAGE
9.0 VDC with plug remove VDC
2..0 VDC with solenoid connect
12.0 VDC with the solenoid energized
5. If the above voltages are correct, this may be an indication of a problem
with the valve or its associated components. Contact you TCS 3000 Service Center for assistance.
6. If the above voltage are NOT correct, replace the following components
with known working units until the problem is resolved: Solenoids
7. TCS 3000 Circuit Boards

Product has
wrong Name

The Register was
never calibrated or
had the name
changed in W&M
Settings.

Go into prover and calibrate the product or change the Name.

Valve doesn’t
shut off

Valve was never set
up or calibrated

Select the product and calibrated the valve for zero shutoff.

Display is read- Channel A and B are Switch wiring between Channel A and B
ing in reverse
wired backwards
Daisy chain
Network Address of
communication registers are not in
is not working
proper sequence
Host and Client Addresses are not in
proper sequence
Totalizers are
incorrect

1. Check the RX and TX wiring between registers.
2. Make sure the printer is wired to the primary HOST register.
3. Check the Device Addresses of each register, with the primary HOST as 1
and CLIENTS from 2 to 8.
4. Make sure the primary HOST register has the Client Address Range set to
communicate with all the TCS 3000 registers in the daisy chain.

Product vs. System
Totalizer

1. The Product Totalizer was not reset when the System Totalizer was reset
to zero.
2. The ticket is configured to print the Product Totalizer instead of the System
Totalizer, or visa-versa.
Ticket is configured
to show Product To- 3. The ticket is configured to print the Net Compensated Totalizer instead of
talizer instead of Systhe Gross Uncompensated Totalizer, or visa-versa.
tem Totalizer
Net vs. Gross
Totalizer

Cant begin a
delivery because the
screen reads
“Delivery Not
Completed”

Last delivery had the
printer enabled, but
the ticket had not
printed.

The delivery ticket must be printed when the printer is communicating with the
TCS 3000. To move on without the printer, either disable the printer or have
the Select Printer changed to None under Printer Settings. You will be able to
Re-print Tickets under the Select Function.

37

“Must Know” & How To
Start Up “Must Knows” for Setup Configuration & Calibration
1) Each Product must be thoroughly configured and calibrated in W&M Settings. There are many parameters that need
to be configured to ensure your system operates properly. Failure to complete the Product Configuration may result
in the TCS3000 to not function correctly.
2) Products that have been calibrated may appear either as an Active or Inactive Product. The TCS 3000 must have at
least 1 Active Product in order to Begin a Shift and Start a Delivery. Products may only be Activated or Deactivated
after a Shift has Ended.
3) The Calibration Screw must be threaded completely into the Calibration setting, or you will not be able to begin a
shift or start a delivery.

38

Warranty Information

—Warranty Information
WARRANTY
New 3000 electronic registers, equipment or components manufactured by Total Control Systems, a division
of Murray Equipment, Inc. (TCS) with which this warranty is enclosed, are warranted by TCS to the original
purchaser only for a period of TWELVE (12) months from installation or eighteen (18) months from the date of
shipment, to be free, under normal use and service, from defects in material and workmanship.
Defects occurring within the stated warranty period, TCS will repair or replace, at TCS’s option; provided that
part or parts are returned to TCS transportation charges prepaid, and TCS’s examination discloses the parts
or workmanship to have been defective upon delivery to the purchaser.
EXCLUSIONS

Warranty does not cover any parts and equipment not manufactured by TCS, but these items may be covered
by separate warranties of their respective manufacturers. This warranty does not extend to any equipment
that has been subjected to misuse, negligence or accident or if operated in any manner other than in accordance with TCS’s operating instructions and specifications.
CLAIM PROCEDURES
In order to obtain performance by TCS of its obligations under this warranty, the original purchaser must obtain a Return Goods Authorization (RGA) number from TCS’s customer service department within 30 days of
discovery of a purported breach of warranty, but not later than the expiration of the warranty period. Once
authorization is received, return the defective meter, piece of equipment, or component covered by this warranty, with transportation charges prepaid, to TCS at the address shown below together with a written statement setting forth the nature of the defect and RGA number.
LIMITATIONS
THERE ARE NO OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED. TCS SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE.
TCS will determine if all parts or meter defect falls within the warranty guidelines and will repair or replace
within a reasonable time span. TCS is not responsible for any in or out bound freight. TCS's sole obligation
that shall represent the buyer's sole and exclusive remedy shall be to repair or at TCS's option to replace any
product or part determined to be defective. In no event shall TCS be liable for any special, direct, indirect, incident, consequential or other damages of similar nature, including without limitation, loss of profits, products,
production time, or loss of expenses of any nature incurred by the buyer or any third party. TCS has not authorized on its behalf any representation or warranties to be made, nor any liability to be assumed except as
expressly provided herein; there is no other express or implied warranty.

DESIGN AND EQUIPMENT CHANGES
Any changes in design or improvements added shall not create any obligation to install same on equipment
previously sold or ordered.

39

TCS900040 REV. 7
2/24/15

2515 Charleston Place
Fort Wayne, IN 46808
Toll Free: (800) 348-4753
Phone: (260) 484-0382
Fax: (260) 484-9230
Email: sales@tcsmeters.com
Website: www.tcsmeters.com

PETRO Contact Information
AFRICA
South Africa

Factory 1 - 16 Bentonite Street
Alrode, Alberton, Johannesburg
South Africa
P: +27 (0)11 864 7758
F: +27 (0) 11 864 1649
E: sales@petroindustrial.co.za

AUSTRALIA
Eastern Australia

Factory 2, 106 Potassium Street
PO Box 407
Narangba QLD 4504
P: 07 3204 9558
F: 07 3293 4852
E: sales@petroindustrial.com.au

Western Australia

2 Competition Way
Wangara WA 6065
P: 08 6305 0855
F: 08 6305 0319
E: saleswa@petroindustrial.com.au

CANADA
Alberta

Bay A, 233175 Range Road 283
Rocky View, AB T1X 0J9
PO Box 75148
Calgary Alberta T3H 3M1 Canada
P: +1 403 998 7190
TOLL FREE: 1855 44 PETRO
F: +1 403 770 8065
E: sales@petroind.ca

UAE
Dubai

Office LB17330, Lobby Building 17
Jebel Ali Free Zone
PO Box 18602
Dubai, United Arab Emirates
P: +971 488 76688
F: +971 488 76932
E: salesuae@petroind.com

PETRO
petroind.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Erin McIntosh
Create Date                     : 2015:02:26 12:26:46-05:00
Modify Date                     : 2015:07:14 08:25:44+10:00
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Creator                         : Erin McIntosh
Creator Tool                    : Microsoft® Publisher 2013
Metadata Date                   : 2015:07:14 08:25:44+10:00
Producer                        : Microsoft® Publisher 2013
Document ID                     : uuid:c3610e44-3093-694a-98f5-ba17ce0ebabb
Instance ID                     : uuid:4a279cc8-e96f-e347-97ef-cafb7db4d3e2
Page Count                      : 41
EXIF Metadata provided by EXIF.tools

Navigation menu