Pool Power Pak II
®

Dual Speed Pump
Models 0-1086-220, 0-1087-220 with Strainer
Assembly and 25 Ft. Cord
Models 0-1086-226, 0-1087-226 with Strainer
Assembly and 3 Ft. Cord
Owner's Guide

PICKUP PHOTO FROM
PREVIOUS OWNER'S GUIDE
P/N 365-1867
11/2000

365-1880

PREPARATION

When installing and using this electrical equipment,
basic safety precautions should always be followed, including the following:

The pump should be connected to a receptalce on a
dedicated circuit protected by a 20 AMP circuit breaker.
DO NOT use a grounding adaptor.
The receptacle must be protected by a Ground Fault
Circuit Interrupter (GFCI) in accordance with Article 68031 of the National Electrical Code (NEC), (Section 68204 of the Canadian Electrical Code (CSA) and local
codes or ordinances. For runs greater than 25 feet,
consult your local licensed electrical contractor.

1. READ AND FOLLOW ALL INSTRUCTIONS.

FOR MODELS 0-1086-226, 0-1087-226 (3 Ft. Cord)

2. WARNING: To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.

Your pump is suppplied with a 3-foot, 3-wire electrical
cord and a 3-prong flanged, twist-lock plug.
The pump electrical cord must be connected to a single
twist lock, grounding type receptalcle that is located a
minimum of 5 feet from the inside pool wall.
A qualified electrical contractor must install this receptacle in accordance with Article 680-6 of the National
Electrical Code (NEC). A Ground Fault Interrupter
(GFCI) must be used. An ON/OFF Switch must be
installed at the receptacle.

IMPORTANT SAFETY INSTRUCTIONS
FOR ALL MODELS:

3. WARNING: Risk of electric shock. Connect only to
a grounding type receptacle protected by a Ground
Fault Interrupter (GFCI).
Contact a qualified electrician if you cannot verify that
the receptacle is protected by a GFCI.
4. Do not bury cord. Locate cord to minimize abuse
from lawn mowers, hedge trimmers, and other
equipment.

Use a Hubbell No. 2310 Receptacle, 20 AMP 125 Volt
A.C. or an equivalent receptalcle that meets NEMA
Configuration L5-20R.

5. WARNING: To reduce the risk of electric shock,
replace damaged cord immediately.

This pump is double insulated and grounded. Dead
metal parts are not in contact with pool water.

6. WARNING: To reduce the risk of electric shock, do
not use an extension cord to connect unit to the
electrical supply; provide a properly located outlet.

CAUTION
1. DO NOT install the pump on a deck, it could fall into
the water, causing severe electrical shock. Do not
install on any surface at, above, or slightly below the
top rail of the pool.

FOR MODELS 0-1086-220, 0-1087-220 (25Ft. Cord)
7. CAUTION: This pump is for use with storable pools
only. Do not use with permanently installed pools. A
storable pool is constructed so it may be readily
disassembled for storage and reassembled to its
original integrity. A permanently installed pool is
constructed in or on the ground or in a building such
that it cannot be readily disassembled for storage.

2. DO NOT allow children or adults to climb, sit, or
stand on the pump unit. They could easily fall.
Position the filter and pump approximately 4 feet
from the pool wall so they may not be used as steps
by children.

FOR MODELS 0-1086-226, 0-1087-226 (3 Ft. Cord)

3. Always keep the water level in your pool between the
water level markers on the skimmer face plate. If the
pump is run with water level too low, the pump seal
may overheat and cause permanent damage to the
pump.

8. CAUTION: This pump is for use with permanently
installed pools and may also be used with hot tubs
and spas if so marked. Do not use with storable
pools. A permanently installed pool is constructed in
or on the ground or in a building such that it cannot
be readily disassembled for storage. A storable pool
is constructed so that it may be readily disassembled
for storage and reassembled to its original integrity.

4. Your Pool Power Pak must sit either in an optional
filter/pump base, on a patio block, or on any firm
surface that slightly elevates the pump off the
ground. This keeps water away from the motor and
prevents the vents of the Power Pak from becoming
blocked, which could cause the motor to overheat.

FOR ALL MODELS:
9. SAVE THESE INSTRUCTIONS.

ELECTRICAL SOURCE
FOR MODELS 0-1086-220, 0-1087-220 (25Ft. Cord)
Your pump is supplied with a 25 foot, 3-wire electrical
cord and a 3-pronged plug. The pump is double insulated and grounded. The pump electrical cord must be
connected to a grounded, 3-wire, 115 VAC electrical
receptacle.
2

POOL POWER PAK II® DUAL SPEED - EXPLODED VIEW
Models with Strainer Assembly & 25 Ft. Cord:
0-1086-220, 0-1087-220
Models with Strainer Assembly & 3 Ft. Cord:
0-1086-226, 0-1087-226

SWITCH ASSEMBLY
36

37

38

39

ITEM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

P/N

QTY

341-1123
324-1018
321-1004
385-1152
1121-1771
300-1150
300-1149
321-1027
1128-1026
308-1040
305-1020
1128-1030
306-1006
1107-1388
1107-1547
330-1027
308-1099
340-1812
340-1813
340-1218
330-1050
1121-1365
1150-1000
1150-1005

1
1
1
2
1
1
1
6
1
1
1
1
1
1
1
4
1
1
1
2
6
1
1
1

DESCRIPTION

ITEM

Insulating Sleeve
1/4"-20 x 1" Bolt
1/4"-20 Hex Nut
Motor Clamp
Top Housing/Decal Assembly
Motor-1 HP w/Slinger
Motor-1-1/2 HP w/Slinger
#10-24 Kep Nut
Pump Backplate Assy.
O-Ring, 1.29 x .013 Wall
Insulator, Ceramic Mating Ring
Ceramic Mating Ring & O-Ring Ass'y
Shaft Seal, 5/8" Diameter
Impeller Assembly, 1HP
Impeller Assembly, 1-1/2
#8 x 1/2" Screw
O-Ring, 5.734 x .139 Wall
Pump Volute
Pump Housing
1/4" Pipe Plug
#10-24 x 1 1/4" Screw
1 & 1-1/2 HP Pump Assembly
Bottom Housing (UL/CSA)
Bottom Housing (NEC/UL)

3

P/N

QTY

26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

348-1026
330-1023
1100-1077
1100-1115
303-1104
303-1120
340-1215
1121-1437
1300-1001
340-1216
308-1167
376-1011
340-1213
308-1046
324-1004
1300-1013
303-1110
303-1350
1100-1691
1100-1078
327-1036

2
6
1
1
1
1
2
1
1
1
1
2
1
1
2
1
1
1
1
1
1

41
42

365-1880
—

1
1

22
23
24
25

DESCRIPTION
Rubber Strip
#8 x 5/8" Screw
Power Cord (UL/CSA)
Power Cord (NEC/UL)
Strain Relief Bushing (UL/CSA)
Strain Relief Bushing (NEC/UL)
Strainer Knob
Strainer Cover w/Decal
Strainer Basket Assy.
Anti-Syphon Rotor
Strainer Gasket
Clip Strainer Body Bolt
Strainer Body
O-Ring, 1.609 x .139 Wall
3/8"-16 x 1 1/2" Bolt
Strainer Assembly
Knurled Ring Nut
Switch
Switch wire Assembly- Blue
Switch Wire Assy
#8 Ext. Tooth Lockwasher (not
shown)
Owner’s Guide
Warranty Card

STRAINER ASSEMBLY INSTALLATION
Press down on the strainer cover while loosening the
two strainer knobs just enough to rotate the cover
counter-clockwise until it stops. Lift off the cover. Inside
the basket you will find assembly screws and instructions for assembling the Strainer to the Power Pak II.
Take care to prevent cross threading. Do not overtighten. The strainer should be snug and in an upright
position when assembled. To replace cover, press
down and rotate clockwise until slots in cover are
completely under knobs. Tighten knobs until cover is
fully seated.

INITIAL START-UP
1. If you have a Doughboy filtration system, follow the
"Initial Start-Up" instructions in the Doughboy Filter
owner's guide.
2. For best results, be sure to select the HIGH
speed switch setting for initial startup, pump
priming, vacuuming, and backwashing the filter.
Use the LOW speed switch setting for surface
skimming and filtering over a longer period of time,
or when energy savings is desired.
3. If this pump has been purchased as a replacement
(and you are not referring to the Doughboy Filter
instructions), the pump will have to be primed after
all hose connections have been made and pool has
been filled to the proper level. To prime the pump,
loosen the pump strainer pot lid to allow air to
escape. Tighten lid when water begins to flow
between strainer pot body and lid. Do not
overtighten.

MAINTENANCE
Make sure the pump is disconnected from the
electrical source before attempting any maintenance
work.

LUBRICATION
Periodically lubricate the O-Ring under the strainer

cover with a NON-PETROLEUM lubricant recommended for A.B.S., Noryl and Acrylic plastics. Consult
your pool dealer for lubricant selections.
If you have any questions or require assistance, contact
your Doughboy pool dealer.

SERVICING SAFETY TIPS
1. ALWAYS TURN “OFF” the main power switch and
the Ground Fault Circuit Interrupter (GFCI) breaker
switch so power is completely off before servicing
your unit.
2. ALWAYS BE SURE THE GROUND UNDER YOUR
FEET AND YOUR BODY IS DRY before you touch
electrical equipment. Failure to heed this warning
may cause personal injury due to severe electrical
shock.
3. ALWAYS have a qualified electrician service your
system if electrical problems occur. This system is
UL listed and must be serviced by a qualified electrician to insure that the electrical integrity is maintained. Failure to do so may cause personal injury
due to severe electrical shock and may void the UL
listing and warranty.
4. ALWAYS have a qualified electrician install a
Ground Fault Circuit Interrupter (GFCI) breaker at
the electrical service or supply panel. Follow GFCI
manufacturer’s operating instructions for testing.
Failure to do so may cause personal injury due to
severe electrical shock.
CAUTION: To reduce the risk of electrical shock,
connect only to grounding type receptacles. A
Ground Fault Circuit Interrupter (GFCI) must be

provided in accordance with local codes or
ordinances.
CAUTION: To reduce the risk of electrical shock,
use only Original Equipment Manufactured (OEM)
replacement parts when servicing.

Change of Design: Doughboy Recreational expressly reserves the right to change or modify the design and construction of any
product in due course of our manufacturing procedures, without incurring any obligation or liability to furnish or install such changes
or modifications on products previously or subsequently sold.

DOUGHBOY RECREATIONAL • 10959 Jersey Blvd., • Rancho Cucamonga, CA 91730
Visit our web site at www.doughboy-pools.com
DB1001-017

Made in the United States of America

Copyright © 2001



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 4
Creator                         : Aldus PageMaker 5.0
Create Date                     : 2002:04:12 12:54:02
Title                           : 
Author                          : Falcon
Producer                        : Acrobat PDFWriter 3.0.1 for Power Macintosh
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu