PRICE LIST
User Manual: PRICE LIST
Open the PDF directly: View PDF .
Page Count: 208
Download | |
Open PDF In Browser | View PDF |
Smith Brothers Stores Ltd Suppliers to Building Services Head Office & Accounts Unit V2 Winchester Avenue, Blaby, Leicester, LE8 4GZ Tel: 0116 222 7330 Fax: 0116 222 7331 email: head.office@sbs.co.uk Branch Locations Bristol Leeds Unit 1 Alpha Park, Units 9/10 Cala Trading Estate, Unit 1 Quantum Business Park, Bevan Way, Smethwick, Ashton Vale Road, Pontefract Road, Stourton, West Midlands, B66 1BZ Bristol, BS3 2HA Leeds, LS10 1AX Tel: 0121 555 1900 Tel: 0117 947 1111 Tel: 0113 201 4222 Fax: 0121 555 1901 Fax: 0117 947 1122 Fax: 0113 201 4223 email: birmingham@sbs.co.uk email: bristol@sbs.co.uk email: leeds@sbs.co.uk Leicester London Northampton 99 Commercial Square, Units 3 & 4 Eurocourt, Unit 3 Reynoldston Close, Freemans Common Industrial Estate, Oliver Close, West Thurrock, Brackmills Industrial Estate, Leicester, LE2 7SR Essex, RM20 3EE Northampton, NN4 7BX Tel: 0116 222 7355 Tel: 01708 689 900 Tel: 01604 763 621 Fax: 0116 244 0430 Fax: 01708 689 901 Fax: 01604 760 903 email: leicester@sbs.co.uk email: london@sbs.co.uk email: northampton@sbs.co.uk Oldham Peterborough Southampton Unit N Oldham Central Trading Park Empson Road Unit 3 St Georges Industrial Estate Coulton Close Eastern Industry Goodwood Road, Boyatt Wood Oldham OL1 4EB Peterborough PE1 5UP Eastleigh SO50 4NT Tel: 0161 621 6288 Tel: 01733 311 711 Tel: 02380 623 070 Fax: 0161 621 6289 Fax: 01733 345 293 Fax: 02380 614 320 email: oldham@sbs.co.uk email: peterborough@sbs.co.uk email: southampton@sbs.co.uk Cardiff Heathrow Unit 2 Dominions Way Industrial Unit 2 Pier Road, Estate, Newport Road, Feltham, Greater London, Cardiff, CF24 1RF TW14 0TW Tel: 02921 671 250 Tel: 0203 8565 620 Fax: 02921 671 251 email: cardiff@sbs.co.uk Registered Office: Batten Street, Aylestone Road, Leicester. LE2 7PB A Member of the Smith Brothers (Leicester) Limited Group of Companies Registration No 962846 Fax: 0203 8565 630 email: heathrow@sbs.co.uk Daikin UK Price List Update: Valid from 1st January 2017 Birmingham Daikin UK Price List R3ON2EVETNS Update: Valid from 1st January 2017 I NOWRE SPL TED M O S E L E C I TS N AND AIR U SKY TOO Residential, Commercial and Industrial Smith Brothers Stores Ltd SBS is one of the oldest and largest independent merchants operating from within the U.K. directly focusing on supplying to the commercial and industrial mechanical services sector. The core business has specialised in the distribution of pipework, valves and all associated fittings for over 100 years. In recent years we were appointed as a Daikin partner dealer and we have complemented this with an extensive air conditioning ancillary range of products. Currently operating from eleven branches, along with a separate Head Office in Leicester, more are planned for the very near future. SBS should be the number one choice for the mechanical services air conditioning contractor who relies on quality of service combined with competitive pricing. With 100 years of experience, comes expertise and credibility. Conditions Capacity Conditions Unit cooling and heating capacities shown within this price list are based on the following conditions: Nominal cooling Ambient = 35°C Internal = 27°C db 19°C wb Nominal heating Ambient = 7°C db 6°C wb Internal = 20°C db Seasonal Efficiency Split and Sky Air Systems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency UK cooling Ambient = 30°C Internal = 22°C db 16°C wb For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year. Heat Source VRV (ESEER) Unless otherwise indicated, all units within this price list are air-cooled. This digital price book update reflects the planned +4% price increase, as communicated to customers in our letter dated 1 October 2016. Please note that, in order to keep our pricing simple, we have rounded to the nearest pound, therefore the exact price increase may be fractionally different to +4% on individual items. ESEER is defined as the European Seasonal Energy Efficiency Ratio and is a measure of the performance of the outdoor unit only. Nominal Efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP. Nominal Efficiencies are used for systems above 12kW. It is not possible to compare Nominal and Seasonal Efficiency ratings due to the different calculation methods used. Daikin UK Price List Update Contents New for 2016 2 Split, Sky Air Heat Pumps 5 VRV 55 Ventilation 109 Heating 113 Refrigeration 163 Applied 171 Services & Training 193 Discount Rating Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference. Split, Sky Air Heat Pumps VRV Ventilation MY DISCOUNT MY DISCOUNT MY DISCOUNT % % % Heating Refrigeration Applied MY DISCOUNT MY DISCOUNT MY DISCOUNT % % % Price List Update: Valid from 1st January 2017 1 New for 2016 FOR EASY ACCESS TO ALL DAIKIN UK CATALOGUES, DATASHEETS, INSTALLATION AND OPERATION MANUALS, LOG INTO THE NEW DAIKIN BUSINESS PORTAL FROM 1 APRIL 2016: MY.DAIKIN.CO.UK BOOK TRAINING NOW AT WWW.DAIKINTRAINING.CO.UK Daikin extends R32 range even further to include more Splits and Sky Air cassette UPDATE FOR 2016 Our range of split and Sky Air systems using the next generation of refrigerants offers: > Lower global warming potential > Higher efficiencies > Lower refrigerant charge Total range now available: > Ururu Sarara > Emura > FTXM High Inverter > Multi units > Duct for multi applications (FDXM-F) > Sky Air Smart HiCOP Cassette Page 6 - 11 Daikin unique Under Ceiling Cassette is now available for connection to Classic Allows even more applications to be served by this truly unique product ideal for solid ceilings Page 33 BRC1E53A controller for duty rotation NEW FOR 2016 Duty rotation standby and back-up for IT applications, works with the new indoor units > Wall mounted FAQ-C9 > Ceiling suspended FHQ-CB Page 49 I W I- F O L TR CO N A P P V IA Remote App control for VRV and Sky Air – and an upgrade for the Split App Ideal for customers who want remote control of their air conditioning system, the VRV and Sky Air Wi-Fi adapter ensures customers can return to the perfect environment. For VRV and Sky Air For Split Page 105 2 Residential, Commercial and Industrial Intelligent Tablet Controller – ideal for single and multistore retail estates or light commercial applications Table t This cloud based control solution with remote access possibilities enables access to fault controls, off-site control and energy management: > Wi-Fi and cloud based control of SkyAir or VRV equipment > Connects directly to Daikin DIII-Net protocol > Single or Multi-site web interface > Web based energy management system Page 104 NEW FOR 2016 Increased piping limitations on VRV IV HR > Indoor to indoor unit maximum height difference has been increased to 30m to give even more system design flexibility > Please ask you sales person to undertake a selection VRV IV Branch selector boxes with pre-fitted valves To further increase the flexibility of the BS boxes, we are now able to offer the full range of multi BS boxes with valves pre fitted. > The benefit of having valves pre-installed on the boxes saves considerable time and effort on site > NEW indoor units can be added without having to remove refrigerant from the rest of the system, so you can avoid having to pump down / vac out / recharge the whole system and save hours when altering systems Page 68 Page 97 Weather proof enclosures for VAM Total Heat Exchangers If you need to install a VAM unit outside of a building, they need to be weatherproofed as they are designed for installation internally. We can offer fully weatherproofed housings for the VAM range which are rated IP46 to make them suitable for outdoor installation. The VAM units are fitted into the enclosure and delivered to site for fuss free installation. Page 111 Daikin UK offer a customised service where we can repaint units to any specified RAL or BS finish > C ustomers sometimes require visible units to be less obtrusive, whether for aesthetic or planning reasons or to meet a specific colour requirement > Available for VRV, Split, Sky Air and all other units as required Page 41 / 69 Strip down and rebuild service – ask for your unit to be dismantled and reassembled for installation in those difficult to access locations > Daikin engineers will strip down and package the unit, organise delivery to the kerb-side > Daikin engineers will then attend site to rebuild, pressure test, and vacuum and charge the unit ready for connection to the rest of the system Page 69 Price List Update: Valid from 1st January 2017 3 NEW FOR 2016 LT Integrated Hydrobox & DHW (floor standing) NEW Netatmo for domestic heating FOR 2016 The smart thermostat, available from January 2016, gives homeowners with Daikin Altherma air-to-water heat pumps the option to control their heating temperature via a smartphone app. Increases the quality and consistency of installations whilst decreasing the complexity and installation time thanks to the compact integration of all the indoor components in a single enclosure. Page 123 Page 138 Industrial refrigeration condensing unit with screw compressor > H igh efficiency inverter controlled compressor, economiser and high performance condenser > Easy to install , ready to connect evaporator > Capacity up to 450 kW on MT and 170 kW LT (@+32°C) Page 170 NEW FOR 2016 > > > > Modular AHU with DX or water packaged solution High efficiency fan motors (IE4) and heat recovery exchangers Full VRV IV or ERQ condenser connection compatibility Complete package with integrated controls Monitoring and control through Daikin ITM Modular Heat Wheel 1200-1500m3/h Launched Modular Plate 1200-1500m3/h Dec 16 NEW FOR 2016 Aircooled DC inverter screw series – Gen 2 TZ series > Introduction of Microchannel coils as standard > Compressors with DC electrical motor & Gen 2 Variable Volume Ratio (VVR) 170-700kW Launched 720-1100kW Launched 1130-1800kW April 17 Page 190 - 192 NEW FOR 2016 Watercooled inverter screw series > AC Inverter driven screw compressors > Market leading full and partload efficiency in its class (best ESEER level) 450-1800kW Launched 4 Residential, Commercial and Industrial NEW FOR 2016 BLDC high static ducted FCU & controller > Completes BLDC range line-up – Low, Medium & High pressure > Provides wider operating range per model at reduced noise levels > NEW FWECSA controller with master/slave networking on RS485 450-1800kW Launched SPLIT, SKY AIR HEAT PUMPS Daikin UK Price List Update Split, Sky Air Heat Pumps Another First From Daikin: R32 6 R32 Wall Mounted Split Systems 7 R32 Multi Systems 10 R32 Sky Air Hi COP Cassette 11 Sky Air Roundflow Cassette 12 Enhanced Capital Allowance (ECA) Scheme 12 R410A Pair Applications 13 Wall Mounted Split Systems 13 Floor Standing Split Systems 18 Ceiling Suspended Split Systems 24 Cassette Split Systems 28 Under Ceiling Cassette Split Systems 32 Ducted Split Systems 35 Multi Applications 40 Multi Split Systems 40 Twin, Triple, Double Twin Systems 43 Infrastructure Cooling 48 Sky Air – Duty Rotation 49 Air Curtains 50 Central Ducted 52 Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 Reasons for change Daikin products using R32 There are a number of options for the next generation refrigerant gas, to meet future legislation and reduce the environmental impact of air conditioning, heat pumps and refrigeration. The choices are generally accepted to be R32, R410A, HFO blends, CO2, and hydrocarbons, including R290 and R600. The 2016 line-up of R32 products has 4 types of split systems. Three are wall mounts, including a brand new FTXM with SEER efficiencies of up to 8.53. We also include a Roundflow cassette: the FCAHG. Daikin’s work with R32 Because of its superior energy efficiency and low GWP, R32 is Daikin’s preferred next generation refrigerant for air conditioners and heat pumps. Its first domestic air conditioners using R32 were introduced to Japan in 2012 and there have been sales in excess of 4 million systems since then. Ururu Sarara (FTXZ) R32 in brief Wall mount (FTXM) Roundflow Cassette (FCAHG) Emura (FTXJ) R32 is already used in HVAC equipment, as it makes up 50% of R410A. It has a global warming potential (GWP) of 675, which is one third that of R410A (2,088). It’s more energy efficient, resulting in a lower refrigerant charge and offering the potential to manufacture smaller units. As a single component refrigerant, it is also easier to reuse and recycle. Like many low GWP refrigerants, R32 is mildly flammable, requiring some new tools and procedures during installation. It is also easier to handle because it doesn’t fractionate when being charged as a vapour. Daikin now also offer a multi-system on R32 for up to five indoor units. These are connectable to the Emura, FTXM or new slim Ducted R32 multi-fancoil: > > > > Ururu Sarara (FTXZ) – see page 7 Emura (FTXJ) – see page 8 Wall mount (FTXM) – see page 9 Roundflow Cassette (FCAHG) – see page 11 Installation and equipment Installation of R32 systems is very similar to R410A systems, although slightly different equipment is required. These include: Using R32 in a split system delivers: > Lower GWP > Higher efficiencies > Smaller refrigerant charge > Gauge manifold > Recovery pump > Electronic leak tester These are available from a number of key manufacturers. Please contact your local stockist. Refrigerant performance Refrigerant Charge SPLIT, SKY AIR HEAT PUMPS Another First From Daikin: R32 1.6 1.2 R22 Tooling R410A R32 Manifold Scale Vacuum pump Leak detector Recovery unit Ventilation * Warnings Recovery bottle Current tool Current Current Current Current Recommended Blue marks 40 bar, right thread Different scale Current Current Different Different Necessary (fan) Blue+Red marks (p16) 48 bar, left thread * when installed in a plant room 0.8 R-410A R32 0.4 0 2.5 3.0 3.5 Energy Efficiency Ratio 6 Refrigerant GWP R22 R410A R32 1,910 2,088 675 Residential, Commercial and Industrial Based on 3.5kW Wall Mount Contact Daikin Training to arrange an R32 Training Course covering: > Daikin’s range of R32 equipment > Installation, equipment & handing of R32 www.daikintraining.co.uk SPLIT, SKY AIR HEAT PUMPS FTXZ-N / RXZ-N Wall Mounted Ururu Sarara (with R32 refrigerant) Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low / S Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low / S Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details FTXZ25N FTXZ35N FTXZ50N 2.79 2.39 2.50 3.60 A+++ 2.50 9.54 92 A+++ 3.50 5.90 831 6.10 / 5.80 A/A 205 0.180 / 0.125 / 0.090 / 0.067 3.90 2.88 3.50 5.00 A+++ 3.50 9.00 136 A+++ 4.50 5.73 1100 5.30 / 5.00 A/A 330 0.200 / 0.140 / 0.090 / 0.067 295 798 372 15 42 / 35 / 27 / 19 57 5.58 3.77 5.00 6.30 A+++ 5.00 8.60 203 A+++ 5.60 5.50 1427 4.55 / 4.47 A/A 550 0.250 / 0.153 / 0.110 / 0.077 RXZ35N RXZ50N 15 38 / 33 / 26 / 19 54 RXZ25N Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Holding Charge Sound Pressure (Cooling) High Sound Power Air Flow Rate High ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m kg dBA dBA m3/sec 1.80 2.8 16 1/4 (6.4) / 3/8 (9.5) 10 8 10 1.34 46 59 0.516 15 47 / 38 / 30 / 23 60 693 x 795 x 300 50 1ph 2.80 4.4 16 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 10 8 10 1.34 48 61 0.573 4.80 6.2 16 1/4 (6.4) / 3/8 (9.5) 10 8 10 1.34 49 63 0.673 ● ● ● £345.00 £938.00 £1,283.00 £405.00 £1,085.00 £1,490.00 £531.00 £1,142.00 £1,673.00 FTXZ / RXZ systems use R32 refrigerant Accessories: Notes: Accessory Ref Description Trade Price BRP069A42 KRP413A1S KRP928A2S KLIC-DD RTD-RA KPMH974A42 KPMH974A402 KPMJ942A4 KPMJ983A4L KPMH950A4L K.CWB90-2 K.DT1 Wi-fi adaptor to connection on on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Hose for humidification (8m length) Humidification hose extension set (2m length) Humidification hose extension joints (10 pieces) L-shaped joints for humidification hose (10 pieces) L-shaped cuffs for humidification hose (10 pieces) Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm £52.00 £78.00 £137.00 £171.00 £157.00 £144.00 £49.00 £37.00 £108.00 £37.00 £37.00 £56.00 i) All fan coils supplied with infrared remote control ARC477A1 ii) The supplied humidifying hose is 8m in length iii) Minimum ambient operating temperatures: RXZ Cooling Heating -10°C -20°C Features: > Complete climate control withe dehumidification, ventilation, air purification and heating & cooling in ONE system > Very high efficiency solution, thanks to Ururu technology & R32 refrigerant > Self cleaning filters ensure optimum air quality & efficiency of operation > Infrared remote controller with backlit display, or optional Online Control via smartphone or tablet > 3 area intelligent eye ensures air is directed away from people in the room, and switches unit to energy-efficient mode if no-one is detected I W I- F O L TR CO N A P P V IA Price List Update: Valid from 1st January 2017 7 SPLIT, SKY AIR HEAT PUMPS FTXJ-MW/S / RXJ-M Wall Mounted – Emura (with R32 refrigerant) Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate Dimensions Weight Sound Pressure Sound Power Matt Crystal White UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption Energy Label EER / COP Annual Energy Consumption High / Low / Silent kW kW kW kW Height Width Depth mm mm mm kg dBA dBA High / Low / Silent Cooling kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details Interconnection Wiring Piping Connections Pipework Sound Pressure Sound Power Air Flow Rate (cooling) FTXJ25MW FTXJ35MW FTXJ50MW FTXJ20MS 2.25 1.84 2.00 2.50 A+++ 2.30 8.73 92 A++ 2.10 4.60 638 A/A 4.64 / 5.00 248 0.148 / 0.073 / 0.043 2.35 3.42 1.88 2.51 2.50 3.50 3.40 4.00 A+++ A++ 2.40 3.50 8.64 7.19 97 170 A++ A++ 2.70 3.00 4.60 4.60 822 913 A/A A/A 4.73 / 4.57 4.09 / 4.04 254 428 0.148 / 0.073 / 0.182 / 0.080 / 0.044 0.048 303 998 212 12 12 38 / 25 / 19 45 / 26 / 20 54 59 4.69 3.09 5.00 5.80 A++ 4.80 7.02 239 A+ 4.60 4.28 1505 A/A 3.35 / 3.65 716 0.182 / 0.113 / 0.060 2.25 1.84 2.00 2.50 A+++ 2.30 8.73 92 A++ 2.10 4.60 638 A/A 4.64 / 5.00 248 0.148 / 0.073 / 0.043 12 45 / 35 / 32 60 12 38 / 25 / 19 54 RXJ50M RXJ20M 12 38 / 25 / 19 54 RXJ20M Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High / Silent High mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/Sec ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price Brushed Aluminium FTXJ20MW 2.67 2.6 10 1/4 (6.4) / 3/8 (9.5) 20 15 10 0.72 46 / 43 61 0.575 RXJ25M RXJ35M 550 x 765 x 285 34 1ph 2.82 4.18 3.6 4.6 10 10 3+E / 1.5 1/4 (6.4) / 1/4 (6.4) / 3/8 (9.5) 3/8 (9.5) 20 20 15 15 10 10 20 0.72 0.72 46 / 43 48 / 45 61 63 0.575 0.616 735 x 825 x 315 47 6.43 6.9 15 2.67 2.6 10 1/4 (6.4) / 1/2 (12.7) 30 20 10 1/4 (6.4) / 3/8 (9.5) 20 15 10 1.3 48 / 45 63 0.830 0.72 46 / 43 61 0.575 FTXJ25MS FTXJ35MS 2.35 3.42 1.88 2.51 2.50 3.50 3.40 4.00 A+++ A++ 2.40 3.50 8.64 7.19 97 170 A++ A++ 2.70 3.00 4.60 4.60 822 913 A/A A/A 4.73 / 4.57 4.09 / 4.04 254 428 0.148 / 0.073 / 0.182 / 0.080 / 0.044 0.048 303 998 212 12 12 38 / 25 / 19 45 / 26 / 20 54 59 RXJ25M FTXJ50MS 4.69 3.09 5.00 5.80 A++ 4.80 7.02 239 A+ 4.60 4.28 1505 A/A 3.35 / 3.65 716 0.182 / 0.113 / 0.060 12 45 / 35 / 32 60 RXJ35M 550 x 765 x 300 34 1ph 2.82 4.18 3.6 4.6 10 10 3+E / 1.5 1/4 (6.4) / 1/4 (6.4) / 3/8 (9.5) 3/8 (9.5) 20 20 15 15 10 10 20 0.72 0.72 46 / 43 48 / 45 61 63 0.575 0.616 RXJ50M 735 x 825 x 315 48 6.43 6.9 15 1/4 (6.4) / 1/2 (12.7) 30 20 10 1.1 48 / 45 63 0.830 ● ● ● ● ● ● ● ● £273.00 £498.00 £771.00 £288.00 £525.00 £813.00 £323.00 £609.00 £932.00 £426.00 £821.00 £1,247.00 £326.00 £498.00 £824.00 £343.00 £525.00 £868.00 £384.00 £609.00 £993.00 £508.00 £821.00 £1,329.00 FTXJ / RXJ systems use R32, for R410A version see page 13 Accessories: Notes: Accessory Ref Description Trade Price BRC073 BRCW901A03 BRCW901A08 KRP413A1S KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.CGS K.CGM Optional Wired Remote controller: BRC1E53 style 3m connection cable for BRC073 8m connection cable for BRC073 Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £83.00 £17.00 £22.00 £78.00 £137.00 £171.00 £157.00 £37.00 £56.00 £223.00 £308.00 i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller ARC466A1 iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures: RXJ Features: > Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round > It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling > Stylish, low-profile design > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > NEW Improved titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low 8 Residential, Commercial and Industrial Cooling Heating -10°C -15°C I W I- F O L TR CO N A P P V IA WI-FI ADAPTOR NOW INCLUDED AS STANDARD SPLIT, SKY AIR HEAT PUMPS FTXM-M / RXM-M Wall Mounted – Standard Inverter (with R32 refrigerant) Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Weight Sound Pressure Sound Power (Cooling) UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption Energy Label EER / COP Annual Energy Consumption High / Low / Silent kW kW kW kW Height Width Depth mm mm mm kg dBA dBA High / Low / Silent kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details FTXM20M FTXM25M FTXM35M FTXM42M FTXM50M FTXM60M FTXM71M 1.95 1.65 2.00 2.50 A+++ 2.00 8.53 83 A+++ 2.30 5.10 632 A/A 4.57 / 5.00 219 0.185 / 0.100 / 0.073 2.44 1.82 2.50 3.40 A+++ 2.50 8.52 103 A+++ 2.40 5.10 659 A/A 4.50 / 5.00 278 0.185 / 0.103 / 0.073 3.42 2.56 3.50 4.00 A+++ 3.40 8.51 140 A+++ 2.50 5.10 686 A/A 4.23 / 4.04 402 0.210 / 0.107 / 0.077 4.11 2.85 4.20 5.40 A++ 4.20 7.50 196 A++ 4.00 4.60 1217 A/A 3.75 / 4.12 560 0.210 / 0.118 / 0.077 4.56 3.14 5.00 5.80 A++ 5.00 7.33 239 A++ 4.60 4.60 1400 A/A 3.68 / 4.00 682 0.275/ 0.193 / 0.172 TBC TBC 7.10 8.20 A++ 6.80 6.11 390 A 6.20 6.20 2278 B/D 3.03 / 3.19 1174 0.285 / 0.200 / 0.178 41 / 25 / 19 57 45 / 29 / 19 60 45 / 30 / 21 60 44 / 36 / 32 59 TBC TBC 6.00 7.00 A++ 6.00 6.90 304 A+ 4.60 4.60 1498 A/A 3.39 / 3.61 885 0.285 / 0.200 / 0.178 295 1040 300 14.5 46 / 37 / 34 60 RXM25M RXM35M RXM42M RXM50M RXM60M RXM71M 44 735 x 870 x 320 44 7.72 6.6 TBC 9.19 9.5 TBC 272 811 294 10 41 / 25 / 19 57 RXM20M Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Sound Power (Cooling) Air Flow Rate (Cooling) High ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec 20 15 10 30 15 10 0.76 46 / 59 0.600 550 x 765 x 285 32 1ph 2.47 3.7 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 20 0.76 46 / 59 0.600 0.76 49 / 61 0.600 1.30 48 / 44 63 0.848 ● ● ● ● £160.00 £454.00 £614.00 £172.00 £496.00 £668.00 £197.00 £575.00 £772.00 £221.00 £648.00 £869.00 32 1.95 3.7 10 20 15 10 32 44 4.23 4.4 10 4.97 6.8 20 735 x 825 x 300 44 1ph 6.48 6.6 20 3+E / 2.5 1/4 (6.4) / 1/2 (12.7) 30 15 10 20 1.40 48 / 44 63 0.840 30 15 10 47 / 38 / 35 60 3+E / 2.5 1/4 (6.4) / 5/8 (15.7) 30 15 10 1.50 48 / 44 63 0.840 1.70 47 / 64 1.122 ● ● ● £306.00 £722.00 £1,028.00 £312.00 £770.00 £1,082.00 £416.00 £1,054.00 £1,470.00 FTXM / RXM systems use R32, for R410A version see page 14 Accessories: Notes: Accessory Ref Description Trade Price BRC073 BRP069A42 BRCW901A03 BRCW901A08 KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.DT2 K.CGS K.CGM Optional Wired Remote controller: BRC1E53 style Wifi adaptor for connection to on-line controller 3m connection cable for BRC073 8m connection cable for BRC073 Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £83.00 £52.00 £17.00 £22.00 £137.00 £171.00 £157.00 £37.00 £56.00 £61.00 £223.00 £308.00 i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures: RXM Cooling Heating -10°C -15°C Features: > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > NEW Air purification using Flash Streamer technology to remove odour & bacteria > 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low I W I- F O L TR CO N A P P V IA Price List Update: Valid from 1st January 2017 9 SPLIT, SKY AIR HEAT PUMPS I W I- F O L TR CO N A P P V IA Multi Series Outdoor unit Capacity Dimensions Weight Electrical Details Refrigerant Circuit Sound power level Sound pressure level Piping Limits Piping Connections *2MXM40M *2MXM50M *3MXM40N Nominal Cooling kW Nominal Heating kW Unit HeightxWidthxDepth mm Unit kg Power Supply Phase / Frequency / Voltage Running Current (cooling) amps Starting Current amps Fuse Rating amps Refrigerant Type Refrigerant Charge kg Cooling dBA Cooling Nom. dBA Heating Nom. dBA Maximum Length m Maximum Vertical Rise IU-OU m Liquid inches (mm) Gas inches (mm) Operation range Cooling Heating Air Flow Rate (Cooling) Cooling 4.0 5.0 4.4 5.7 550x765x285 36 41 4.6 16 R32 0.88 60 48 50 20 15 1/4 (6.4) 2 x 3/8 (9.5) Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB High / Nom / Super low m3/sec Number of connected indoor units * preliminary data Connectable indoor units 2MXM40M 2MXM50M 3MXM40N 3MXM52N 3MXM68N 4MXM68N 4MXM80N 5MXM90N 6.3 16 R32 1.15 60 46 48 20 15 1/4 (6.4) 3/8 (9.5) 1/2 (12.7) 0.617 / 0.567 / 0.567 2 0.700 / 0.700 / 0.400 3 £1,038.00 £1,149.00 £1,082.00 Wall mounted *Daikin Emura FTXJ-MW/S 20 25 35 50 20 25 *FTXM-M 35 42 50 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l *3MXM68N *4MXM68N *4MXM80N *5MXM90N 5.2 6.8 6.8 8.0 9.0 6.8 8.6 8.6 9.6 10.4 735x 958 x340 735x958 x340 735x958x340 57 57 62 63 67 68 1~ / 50 / 220-240 Refer to Multi Combination Tables 4.1 4.6 9.8 8.3 11.2 11.8 32 32 32 32 32 32 R32 R32 R32 R32 R32 R32 1.80 1.80 1.80 2.00 2.40 2.40 59 59 61 61 61 64 46 46 48 48 49 52 47 47 48 48 49 52 25 25 25 25 25 25 15 15 15 15 15 15 3 x 1/4 (6.4) 3 x 1/4 (6.4) 3 x 1/4 (6.4) 4 x 1/4 (6.4) 4 x 1/4 (6.4) 5 x 1/4 (6.4) 1 x 3/8 (9.5) 1 x 3/8 (9.5) 1 x 3/8 (9.5) 2 x 3/8 (9.5) 1 x 3/8 (9.5) 2 x 3/8 (9.5) 2 x 1/2 (12.7) 2 x 1/2 (12.7) 2 x 1/2 (12.7) 2 x 1/2 (12.7) 1 x 1/2 (12.7) 1 x 1/2 (12.7) 2 x 5/8 (15.7) 2 x 5/8 (15.7) 0.600 / 0.550 / 0.500 2 Trade Condensing Unit Price *3MXM52N 4.0 4.6 60 71 -10~46 -15~24 0.700 / 0.700 0.775 / 0.708 / 0.400 / 0.402 3 3 £1,203.00 £1,703.00 0.818 / 0.753 / 0.402 4 0.818 / 0.818 / 0.402 5 £1,837.00 £2,069.00 £2,227.00 Concealed ceiling *FDXM-F 25 35 50 60 l l l l l l l l l l l l l l l l l l l l l l l l l l l l 0.775 / 0.708 / 0.402 4 l Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units. The online tool has four simple steps: > select number of rooms > select capacity per room > select capacity of outdoor > select type of indoor & input pipe run & level difference It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor unit and generates a report showing full energy label for specific combination and pictures of all equipment selected. This can be used by installers to select Multi systems, and also to show end-users the configuration of the system. Go to www.daikineurope.com/multiselection Multi Split Fan Coils R32 Emura Wall Mounted Fan Coil Units Trade Fan Coil Unit Price FTXJ20MW FTXJ25MW FTXJ35MW FTXJ50MW FTXJ20MS FTXJ25MS FTXJ35MS FTXJ50MS £273.00 £288.00 £323.00 £426.00 £326.00 £343.00 £384.00 £508.00 R32 Wall Mounted Fan Coil Units Trade Fan Coil Unit Price FTXM20M FTXM25M FTXM35M FTXM42M FTXM50M FTXM60M FTXM71M £160.00 £172.00 £197.00 £221.00 £306.00 £312.00 £416.00 R32 Slim Ducted Fan Coil Units Trade Fan Coil Unit Price FDXM25F £331.00 FDXM35F £380.00 FDXM50F £418.00 FDXM60F £466.00 Slim Ducted – for use with R32 Multi Indoor unit Dimensions Weight Air filter Fan - Air flow rate Unit Unit Type Cooling Heating Fan - External static pressure FDXM High/Nom./Low High/Nom./Low Nom Sound power level Cooling Heating Sound pressure level Cooling High/Nom./Low Heating High/Nom./Low Piping connections Liquid Gas Power supply Phase / Frequency / Voltage Control systems Infrared remote control Wired remote control * preliminary data 10 *25F HeightxWidthxDepth mm kg Residential, Commercial and Industrial m³/sec m³/sec Pa dBA dBA dBA dBA inches (mm) inches (mm) Hz / V *35F *50F 200x750x620 21 0.145/0.133/0.122 0.145/0.133/0.122 30 Removable / washable / mildew proof 0.200/0.183/0.167 0.267/0.247/0.225 0.267/0.247/0.225 40 53 53 35/33/27 35/33/27 1/4 (6.4) 3/8 (9.5) *60F 200x1,150x620 30 55 55 38/36/30 56 56 38/35/30 38/36/30 1/4 (6.4) 3/8 (9.5) 1/4 (6.4) 1/2 (12.7) 1~ / 50 / 230 1/4 (6.4) 1/2 (12.7) 1~ / 50 / 220-240 BRC4C65 BRC1E53 SPLIT, SKY AIR HEAT PUMPS FCAHG-F / RZAG-L High COP Roundflow Cassette – Seasonal Smart (R32) Indoor Units Single Phase Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency Energy Label EER / COP Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / night quite mode Sound Power (Cooling) Nom Air Flow Rate (Cooling) High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg FCAHG71F FCAHG100F FCAHG125F FCAHG140F 7.76 5.32 6.80 7.50 A++ 6.80 7.35 324 A+ 4.54 4.54 1743 A/A 4.09 / 4.80 831 0.353 / 0.270 / 0.203 288(348) 840 (950) 840 (950) 25 (30.5) 36 / 33 / 29 53 10.80 7.44 9.50 10.80 A++ 9.50 7.35 452 A++ 4.64 4.80 2753 A/A 4.42 / 4.99 1075 0.538 / 0.428 / 0.317 288 (348) 840 (950) 840 (950) 26 (31.4) 44 / 39 / 33 61 13.60 9.30 12.00 13.50 A++ 12.0 6.94 605 A++ 4.63 4.63 2879 A/A 4.00 / 4.00 1500 0.558 / 0.445 / 0.332 288 (348) 840 (950) 840 (950) 26 (31.4) 45 / 40 / 35 61 14.90 10.25 13.40 15.50 A/A 3.35 / 4.12 2000 0.558 / 0.455 / 0.352 288 (348) 840 (950) 840 (950) 26 (31.4) 45 / 41 / 37 61 RZAG71LV1 RZAG100LV1 RZAG125LV1 RZAG140LV1 95 1430 x 940 x 320 95 95 26.4 4 32 26.4 4 32 85 30 30 85 30 30 990 x 940 x 320 69 1ph A A A inches m m m g/m kg dBA dBA m3/sec 16.5 4 20 26.3 4 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 55 30 30 2.6 48 / 43 64 0.983 £819.00 £1,239.00 £2,058.00 85 30 30 Refer to Installation Manual 3.6 3.6 49 / 45 51 / 45 64 66 1.167 1.167 £926.00 £1,575.00 £2,501.00 £1,012.00 £1,733.00 £2,745.00 3.6 52 / 45 67 1.167 £1,215.00 £1,978.00 £3,193.00 FCAHG / RZAG systems use R32, for R410A version see page 28 Accessories: Accessory Ref BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDQ55B140 1&2 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL Notes: Description Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ Trade Price £158.00 £323.00 £167.00 £103.00 £94.00 £243.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £47.00 £61.00 £308.00 £369.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7FA532F Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £148.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures: RZAG Cooling Heating -15°C -20°C Features: > The FCAHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Optional Fresh Air intake (up to 20%) possible > Re-use of existing R22 and R407C piping possible > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard Price List Update: Valid from 1st January 2017 11 SPLIT, SKY AIR HEAT PUMPS Sky Air Roundflow Cassette One cassette, 3 options: Daikin’s Roundflow Cassette range has a solution for all your needs: > Price > Performance > Highest Efficiency > > > > > Pair applications 30m pipe run -5 / -15°C operating range in cooling / heating A/A Energy Labels R22 replacement technology FCQG-F Series cassette BYFQ140D Roundflow decoration panel BRC1E52 remote control > > > > > Pair, twin, triple, double twin applications 50m pipe run -15 / -15°C operating range in cooling / heating A+/A+ Energy Labels R22 replacement technology > > > > > > Pair, twin, triple, double twin applications 75m pipe run -15 / -20°C operating range in cooling / heating Up to A++/A+ Energy Labels All capacities ECA Eligible R22 replacement technology Enhanced Capital Allowance (ECA) Scheme The Enhanced Capital Allowance (ECA) scheme provides businesses with enhanced tax relief for investment in energy-saving equipment that meets specified Government criteria. It allows 100% of the investment to be written off against taxable profit in the year the investment is made. The Energy Technology List (ETL) is a definitive list of all the products that qualify for the ECA, typically by meeting or exceeding efficiency standards. For DX, the list includes approximately the top 20% most efficient air conditioning systems and is updated regularly to ensure that it includes the most energy efficient products currently available. 12 Residential, Commercial and Industrial Daikin now has a website that allows customers to check whether selected equipment is efficient enough to be eligible to claim Enhanced Capital Allowances. Go to www.daikin.co.uk/eca to check: > Split > Sky Air > VRV The website also allows you to create a Certificate of Eligibility for your equipment selection that can be used to support a claim for ECA. Certain types of equipment are listed on the ECA website. To check eligibility of the following equipment types, please go to www.etl.decc.gov.uk/etl/site.htm > Biddle Air Curtains (Split and VRV) > Ventilation (VAMs) > Control Options (RTD20) > Chillers The ETL website should also be used to check equipment eligibility for Split, Sky Air & VRV equipment purchased before August 2014. SPLIT, SKY AIR HEAT PUMPS FTXG-LW/S / RXG-L Wall Mounted – Emura Indoor Units Matt Crystal White FTXG20LW Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low / Silent kW kW kW kW Height Width Depth mm mm mm kg dBA dBA Weight Sound Pressure (Cooling) High / Low / Silent Sound Power kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details 2.25 1.84 2.00 2.50 A+++ 2.30 8.52 94 A++ 2.10 4.60 639 4.59 / 5 A/A 250 0.148 / 0.073 / 0.043 12 38 / 25 / 19 54 RXG20L Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power (Cooling) Air Flow Rate High ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec 2.70 2.8 16 20 15 10 1.05 46 / 43 61 0.575 FTXG25LW FTXG35LW 2.35 3.42 1.88 2.51 2.50 3.50 3.40 4.00 A+++ A++ 2.40 3.50 8.50 7.00 99 175 A++ A++ 2.70 3.00 4.60 4.60 821 913 4.59 / 4.42 3.97 / 4.06 A/A A/A 261 441 0.148 / 0.073 / 0.182 / 0.080 / 0.043 0.048 303 998 212 12 12 38 / 25 / 19 45 / 26 / 20 54 59 RXG25L RXG35L 550 x 765 x 285 35 1ph 2.80 4.80 4.4 5.5 16 16 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 20 15 15 10 10 20 1.05 1.05 46 / 43 48 / 44 61 63 0.575 0.616 Silver FTXG50LW FTXG20LS 4.69 3.09 5.00 5.80 A++ 4.80 6.70 251 A+ 4.60 4.24 1519 3.53 / 3.65 A/A 680 0.182 / 0.113 / 0.060 2.25 1.84 2.00 2.50 A+++ 2.30 8.52 94 A++ 2.10 4.60 639 4.59 / 5 A/A 250 0.148 / 0.073 / 0.043 12 46 / 35 / 32 60 12 38 / 25 / 19 54 RXG50L RXG20L 735 x 825 x 300 48 6.20 7.4 20 2.70 2.8 16 1/4 (6.4) / 1/2 (12.7) 30 20 10 20 15 10 1.6 48 / 44 63 0.830 1.05 46 / 43 61 0.575 FTXG25LS FTXG35LS 2.35 3.42 1.88 2.51 2.50 3.50 3.40 4.00 A+++ A++ 2.40 3.50 8.50 7.00 99 175 A++ A++ 2.70 3.00 4.60 4.60 821 913 4.59 / 4.42 3.97 / 4.06 A/A A/A 261 441 0.148 / 0.073 / 0.182 / 0.080 / 0.043 0.048 303 998 212 12 12 38 / 25 / 19 45 / 26 / 20 54 59 RXG25L FTXG50LS 4.69 3.09 5.00 5.80 A++ 4.80 6.70 251 A+ 4.60 4.24 1519 3.53 / 3.65 A/A 680 0.182 / 0.113 / 0.060 12 46 / 35 / 32 60 RXG35L RXG50L 550 x 765 x 285 35 1ph 2.80 4.80 4.4 5.5 16 16 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 20 15 15 10 10 20 1.05 1.05 46 / 43 48 / 44 61 63 0.575 0.616 735 x 825 x 300 48 6.20 7.4 20 1/4 (6.4) / 1/2 (12.7) 30 20 10 1.6 48 / 44 63 0.830 ● ● ● ● ● ● ● ● £273.00 £498.00 £771.00 £288.00 £525.00 £813.00 £323.00 £609.00 £932.00 £426.00 £821.00 £1,247.00 £326.00 £498.00 £824.00 £343.00 £525.00 £868.00 £384.00 £609.00 £993.00 £508.00 £821.00 £1,329.00 Accessories: Notes: Accessory Ref Description Trade Price BRC073 BRCW901A03 BRCW901A08 BRP069A41 KRP413A1S KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.CGS K.CGM Optional Wired Remote controller: BRC1E53 style 3m connection cable for BRC073 8m connection cable for BRC073 Wifi adaptor for connection to on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £83.00 £17.00 £22.00 £40.00 £78.00 £137.00 £171.00 £157.00 £37.00 £56.00 £223.00 £308.00 i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller ARC466A1 iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Control option is either hard-wired remote, or Wi-Fi adaptor v) Minimum ambient operating temperatures: RXG Cooling Heating -10°C -15°C Features: > Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round > It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling > Stylish, low-profile design > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible I W I- F O L TR CO N A P P V IA Price List Update: Valid from 1st January 2017 13 SPLIT, SKY AIR HEAT PUMPS FTXS-K/G / RXS-L/F Wall Mounted – Standard Inverter Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low / Silent kW kW kW kW Height Width Depth mm mm mm kg dBA dBA Weight Sound Pressure (Cooling) High / Nom / Low / Silent Sound Power kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price FTXS-K series FTXS-G series FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71G 1.95 1.65 2.00 2.50 A++ 2.00 7.40 95 A++ 2.30 4.77 675 4.65 / 4.72 A/A 228 0.147 / 0.078 / 0.065 289 780 215 8 40 / 32 / 24 / 19 58 2.44 1.82 2.50 3.40 A++ 2.50 7.90 111 A++ 2.50 4.78 732 4.21 / 4.67 A/A 297 0.152 / 0.083 / 0.065 289 780 215 8 41 / 33 / 25 / 19 58 3.42 2.56 3.50 4.00 A++ 3.50 7.47 164 A++ 3.50 4.85 1039 3.89 / 4.76 A/A 450 0.187 / 0.097 / 0.068 298 900 215 11 45 / 37 / 29 / 19 59 4.11 2.85 4.20 5.40 A++ 4.20 6.80 216 A+ 4.00 4.20 1334 3.35 / 4.12 A/A 627 0.187 / 0.117 / 0.068 298 900 215 11 45 / 39 / 33 / 21 59 4.56 3.14 5.00 5.80 A++ 5.00 6.80 257 A+ 4.60 4.20 1535 3.32 / 4 A/A 753 0.198 / 0.123 / 0.075 298 900 215 11 46 / 40 / 34 / 23 60 5.86 3.87 6.00 7.00 A 6.00 5.58 376 A 4.80 3.89 1728 3.02 / 3.43 B/B 995 0.267 / 0.188 / 0.168 290 1050 250 12 45 / 41 / 36 / 33 60 6.94 4.65 7.10 8.20 A 7.10 5.23 475 A 6.50 3.50 2593 3.02 / 3.22 B/C 1175 0.287 / 0.192 / 0.175 290 1050 250 12 46 / 42 / 37 / 34 63 RXS20L3 RXS25L3 RXS35L3 RXS42L RXS50L RXS60L 550 x 765 x 285 34 2.30 2.4 10 20 15 10 1.0 46 / 43 59 0.558 550 x 765 x 285 34 34 1ph 3.10 4.10 3.3 4.3 10 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 20 15 15 10 10 20 1.0 1.2 46 / 43 48 / 44 59 61 0.558 0.600 735 x 825 x 300 39 47 RXS71F8 48 770 x 900 x 320 71 8.80 9.4 20 10.49 11.7 20 1ph 5.70 6.6 20 20 15 10 1.3 48 / 44 61 0.621 6.30 6.8 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 30 20 20 10 10 20 1.7 1.5 48 / 44 49 / 46 62 62 0.848 0.835 ● ● ● ● ● £160.00 £454.00 £614.00 £172.00 £496.00 £668.00 £197.00 £575.00 £772.00 £221.00 £648.00 £869.00 £306.00 £722.00 £1,028.00 Accessories: £312.00 £770.00 £1,082.00 1/4 (6.4) / 5/8 (15.9) 30 20 10 2.3 52 / 49 65 0.910 £416.00 £1,054.00 £1,470.00 Notes: Accessory Ref Description Trade Price KRP980A1 BRC073 BRP069A42 BRCW901A03 BRCW901A08 KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.DT2 K.CGS K.CGM S21 adaptor for FTXS20K & 25K for ALL control options Optional Wired Remote controller: BRC1E53 style Wifi adaptor for connection to on-line controller 3m connection cable for BRC073 8m connection cable for BRC073 Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £52.00 £83.00 £52.00 £17.00 £22.00 £137.00 £171.00 £157.00 £37.00 £56.00 £61.00 £223.00 £308.00 i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Control option is either hard-wired remote, or Wi-Fi adaptor v) FTXS-K and FTXS-G have different style casing vi) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C Features: > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible 14 Residential, Commercial and Industrial I W I- F O L TR CO N A P P V IA SPLIT, SKY AIR HEAT PUMPS FTX-KV / RX-K Wall Mounted – Low Inverter Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate Dimensions Weight Sound Pressure Sound Power FTX20KV UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low / S Low Height Width Depth High / Nom / Low / S Low kW kW kW kW kW kWh kW kWh kWh m3/min mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Interconnection Wiring Piping Connections Pipework Sound Pressure Sound Power Air Flow Rate (Cooling) FTX25KV RX20K Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High High Trade Fan Coil Price Trade Condensing Unit Price Total System Price FTX35KV FTX50KV FTX60KV FTX71KV 1.95 2.44 3.42 4.89 5.86 6.93 1.65 1.82 2.56 3.42 4.00 4.73 2.00 2.50 3.50 5.00 6.00 7.10 2.50 3.40 4.00 6.00 7.00 8.20 A++ A++ A++ A++ A++ A 2.00 2.50 3.50 5.00 6.00 7.10 6.66 6.55 6.44 6.59 6.76 5.25 105 134 190 266 311 473 A++ A++ A++ A+ A+ A 2.20 2.40 2.80 4.60 4.80 6.20 4.65 4.61 4.64 4.10 4.10 3.81 662 729 845 1570 1640 2227 3.98 / 4.77 3.78 / 4.36 3.43 / 4.02 3.58 / 3.80 3.65 / 3.63 2.61 / 3.19 A/A A/A A/A A/A A/A 251 331 510 698 822 1360 0.165 / 0.096 / 0.080 0.173 / 0.101 / 0.080 0.196 / 0.105 / 0.081 0.266 / 0.185 / 0.168 0.293 / 0.203 / 0.186 0.293 / 0.203 / 0.186 286 286 286 295 295 295 770 770 770 990 990 990 225 225 225 263 263 263 8 8 8 13.5 13.5 13.5 39 / 33 / 25 / 20 40 / 33 / 26 / 20 43 / 34 / 27 / 20 43 / 39 / 34 / 31 45 / 41 / 36 / 33 46 / 42 / 37 / 34 55 55 59 59 60 62 mm kg RX25K A A A 2.17 3.0 16 inches (mm) m m m g/m kg dBA dBA m3/sec 15 12 10 20 0.74 46 60 0.486 550 x 658 x 275 28 1ph 2.87 3.7 16 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 15 12 10 20 0.74 46 60 0.486 £112.00 £333.00 £445.00 £124.00 £356.00 £480.00 RX35K RX50K RX60K RX71K 4.44 5.2 16 6.11 7.0 20 15 12 10 20 1.00 48 62 0.460 30 20 10 20 1.13 47 61 1.063 735 x 870 x 320 49 1 ph 7.21 9.9 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 20 1.45 49 63 1.045 £141.00 £414.00 £555.00 £229.00 £539.00 £768.00 £233.00 £575.00 £808.00 44 Accessories: 49 11.67 9.9 20 30 20 10 20 1.45 52 66 TBC £311.00 £826.00 £1,137.00 Notes: Accessory Ref Description Trade Price BRC073 BRP069A42 BRCW901A03 BRCW901A08 K.CWB90-2 K.DT1 K.DT2 K.CGS K.CGM Optional Wired Remote controller: BRC1E53 style Wifi adaptor for connection to on-line controller 3m connection cable for BRC073 8m connection cable for BRC073 Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £83.00 £52.00 £17.00 £22.00 £37.00 £56.00 £61.00 £223.00 £308.00 i) All fan coils supplied as standard with infrared remote controller ii) All fan coil units standard with auto restart after power failure iii) Minimum ambient operating temperatures: RX Cooling Heating -10°C -15°C Features: > > > > > > > Wireless remote controller with daily timer Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting Fan speed: 5 fan speeds can be selected, high to super low Suitable for multi model applications Re-use of existing R22 and R407C piping possible I W I- F O L TR CO N A P P V IA Price List Update: Valid from 1st January 2017 15 SPLIT, SKY AIR HEAT PUMPS FAQ-C9 / RZQG-L Wall Mounted – Seasonal Smart Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nominal mm kg 3 Phase FAQ71C9 FAQ100C9 FAQ71C9 FAQ100C9 7.76 5.32 6.80 7.50 A++ 6.80 6.43 371 A+ 6.33 4.02 2205 3.4 / 3.7 A/A 1000 0.300 / 0.267 / 0.233 290 1050 238 13 45 / 42 / 40 61 10.80 7.44 9.50 10.80 A++ 9.50 6.11 545 A+ 10.20 4.01 3562 3.62 / 3.61 A/A 1315 0.433 / 0.383 / 0.317 340 1200 240 17 49 / 45 / 41 65 7.76 5.32 6.80 7.50 A++ 6.80 6.43 371 A+ 6.33 4.02 2205 3.4 / 3.7 A/A 1000 0.300 / 0.267 / 0.233 290 1050 238 13 45 / 42 / 40 61 10.80 7.44 9.50 10.80 A++ 9.50 6.11 545 A+ 10.20 4.01 3562 3.62 / 3.61 A/A 1315 0.433 / 0.383 / 0.317 340 1200 240 17 49 / 45 / 41 65 RZQG71L9V1 RZQG100L9V1 RZQG71L8Y1 RZQG100L8Y1 990 x 940 x 320 69 1430 x 940 x 320 95 990 x 940 x 320 80 1430 x 940 x 320 101 10.75 4 32 3.07 4 16 1ph A A A 8.17 4 20 inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price 3ph 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 30 30 4.04 4 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 30 30 50 30 30 Refer to Installation Manual 2.9 4.0 48 / 43 50 / 45 64 66 0.983 1.166 75 30 30 Refer to Installation Manual 2.9 4.0 48 / 43 50 / 45 64 66 0.983 1.116 ● ● ● ● £779.00 £1,239.00 £2,018.00 £841.00 £1,575.00 £2,416.00 £779.00 £1,277.00 £2,056.00 £841.00 £1,648.00 £2,489.00 For Comms Rooms & Duty Rotation see page 48 - 49 Accessories: Notes: Accessory Ref Description Trade Price BRC7EB518 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL Wireless remote controller Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £158.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £47.00 £61.00 £308.00 £369.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7EB518 Trade price will be reduced by £79.00 if ordered instead of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG RZQSG Features: > > > > > > > > > Fan speed: 3 fan speeds available on all capacities Automatic airflow volume control sets fan speed based on difference between set and room temperatures Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart) DIII net compatibility as standard Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet) Suitable for Twin, Triple and Double Twin applications 16 Residential, Commercial and Industrial Cooling Heating -15°C -15°C -20°C -15°C SPLIT, SKY AIR HEAT PUMPS FAQ-C9 / RZQSG-L Wall Mounted – Seasonal Classic Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power (Cooling) kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power (Cooling) Air Flow Rate (Cooling) Nominal Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg 3 Phase FAQ71C9 FAQ100C9 FAQ100C9 7.28 4.99 6.80 7.50 A+ 6.80 5.81 410 A 6.33 3.90 2273 3.21 / 3.61 A/A 1060 0.300 / 0.267 / 0.233 290 1050 238 13 45 / 42 / 40 61 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 6.81 4.01 2378 3.01 / 3.41 B/B 1580 0.433 / 0.383 / 0.317 340 1200 240 17 49 / 45 / 41 65 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 6.81 4.01 2378 3.01 / 3.41 B/B 1580 0.433 / 0.383 / 0.317 340 1200 240 17 49 / 45 / 41 65 RZQSG71L3V1 RZQSG100L9V1 RZQSG100L8Y1 770 x 900 x 320 67 990 x 940 x 320 72 2.75 49 / 47 65 0.866 2.9 53 / 49 70 1.266 990 x 940 x 320 82 3ph 4.86 4 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 30 30 Refer to Installation Manual 2.9 53 / 49 70 1.266 £779.00 £853.00 £1,632.00 £841.00 £1,181.00 £2,022.00 £841.00 £1,217.00 £2,058.00 1ph A A A inches (mm) m m m g/m kg dBA dBA m3/sec 8.66 4 20 12.91 4 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 15 30 50 30 30 Refer to Installation Manual Price List Update: Valid from 1st January 2017 17 SPLIT, SKY AIR HEAT PUMPS FVXG-K / RXG-L Stylish Floor Standing Cased – Nexura Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low / Silent Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low / Silent Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible FVXG25K FVXG35K FVXG50K 2.44 1.93 2.50 3.40 A++ 2.50 6.53 134 A++ 2.80 4.65 842 4.63 / 4.42 A/A 270 0.148 / 0.148 / 0.088 / 0.075 600 950 215 22 38 / 32 / 26 / 23 52 3.42 2.37 3.50 4.50 A++ 3.50 6.48 189 A+ 3.10 4.00 1087 3.72 / 3.75 A/A 470 0.155 / 0.155 / 0.088 / 0.075 600 950 215 22 39 / 33 / 27 / 24 52 4.81 3.17 5.00 5.80 A+ 5.00 5.41 324 A+ 4.60 4.18 1543 3.31 / 3.69 A/A 755 0.177 / 0.177 / 0.122 / 0.100 600 950 215 22 44 / 40 / 36 / 32 58 RXG25L RXG35L RXG50L 550 x 765 x 300 35 735 x 825 x 315 48 35 1ph 4.64 5.5 10 2.68 4.4 10 6.04 7.4 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 1.05 46 / 43 61 0.575 20 15 10 20 1.05 48 / 44 63 0.616 1.60 48 / 44 63 0.830 ● Trade Fan Coil Price Trade Condensing Unit Price Total System Price £657.00 £525.00 £1,182.00 £707.00 £609.00 £1,316.00 Accessories: £774.00 £821.00 £1,595.00 Notes: Accessory Ref Description Trade Price BRC073 BRP069A42 BRCW901A03 BRCW901A08 KRP413A1S KRP928A2S KLIC-DD RTD-RA BKS028 K.CWB90-2 K.DT1 K.CGS K.CGM Optional Wired Remote controller: BRC1E53 style Wifi adaptor for on-line controller 3m connection cable for BRC073 8m connection cable for BRC073 Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Leg for floor-standing installation Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £83.00 £52.00 £17.00 £22.00 £78.00 £137.00 £171.00 £157.00 £409.00 £37.00 £56.00 £223.00 £308.00 i) All fan coils supplied as standard with infrared remote controller ARC466AZ ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Control option is either hard-wired remote, or Wi-Fi adaptor v) Minimum ambient operating temperatures: RXG Cooling Heating -10°C -15°C Features: > Radiant Heat panel provides radiator-like warming at the touch of a button > Energy efficient units: full range A class energy labels > Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting I W I- F O L TR > Extremely quiet in operation: down to 19dBA sound pressure level CO N A P P V IA > Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops, so you can sleep more comfortably > Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to ensure a harmonized temperature > Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list). Ideal for installation beneath a window > Suitable for multi model applications > Re-use of existing R22 and R407 piping possible 18 Residential, Commercial and Industrial SPLIT, SKY AIR HEAT PUMPS FVXS-F / RXS-L Floor Standing Cased Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low / Silent Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low / Silent Sound Power High kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power High Air Flow Rate (Cooling) High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec FVXS25F FVXS35F FVXS50F 2.44 1.87 2.50 3.40 A+ 2.50 5.74 152 A+ 2.60 4.56 798 4.12 / 4.42 A/A 303 0.137 / 0.137 / 0.080 / 0.068 600 700 210 14 38 / 32 / 26 / 23 52 3.42 2.34 3.50 4.50 A+ 3.50 5.60 219 A 2.90 3.93 1033 3.30 / 3.78 A/A 530 0.142 / 0.142 / 0.082 / 0.075 600 700 210 14 39 / 33 / 27 / 24 52 4.89 3.21 5.00 5.80 A+ 5.00 5.89 297 A 4.20 3.80 1546 3.23 / 3.63 A/A 775 0.178 / 0.178 / 0.130 / 0.110 600 700 210 14 44 / 40 / 36 / 32 60 RXS25L3 RXS35L3 RXS50L 550 x 765 x 285 34 550 x 765 x 285 34 1ph 4.70 4.3 10 735 x 825 x 300 47 3.30 3.3 10 6.80 6.8 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 1.0 46 / 43 59 0.558 20 15 10 20 1.2 48 / 44 61 0.600 £544.00 £496.00 £1,040.00 £587.00 £575.00 £1,162.00 Accessories: 1.7 48 / 44 62 0.848 £641.00 £722.00 £1,363.00 Notes: Accessory Ref Description Trade Price BRP069A42 KRP413A1S KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.CGS K.CGM Wifi adaptor for on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £52.00 £78.00 £137.00 £171.00 £157.00 £37.00 £56.00 £223.00 £308.00 i) All fan coils supplied as standard with infrared remote controller ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C Features: > > > > > > > > Extremely quiet, energy efficient and can be installed against the wall or recessed Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature I W I- F O L TR Suitable for multi model applications CO N A P P V IA Re-use of existing R22 and R407C piping possible Price List Update: Valid from 1st January 2017 19 SPLIT, SKY AIR HEAT PUMPS FLXS-B / RXS-L Flexi-Floor or Ceiling Mounted Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low / Silent Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low / Silent Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High / Super low mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec Trade Fan Coil Price Trade Condensing Unit Price Total System Price FLXS25B FLXS35B9 FLXS50B 2.44 1.65 2.50 3.40 A 2.50 5.19 169 A 2.50 3.80 921 3.85 / 3.54 A/B 325 0.127 / 0.127 / 0.100 / 0.087 490 1050 200 16 37 / 34 / 31 / 28 51 3.34 2.14 3.50 4.00 B 3.50 4.87 252 A 2.90 3.80 1068 2.88 / 3.57 B/B 608 0.143 / 0.127 / 0.110 / 0.093 490 1050 200 16 38 / 35 / 32 / 29 53 4.82 3.16 4.90 6.10 A 4.90 5.25 326 A 4.20 3.80 1546 2.85 / 3.35 C/C 860 0.190 / 0.190 / 0.142 / 0.125 490 1050 200 17 47 / 43 / 39 / 36 60 RXS25L3 RXS35L3 RXS50L 550 x 765 x 285 34 550 x 765 x 285 34 1ph 5.10 4.3 10 735 x 825 x 300 47 3.60 3.3 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 1.0 46 / 43 59 0.558 / 0.502 20 15 10 20 1.2 48 / 44 61 0.600 / 0.502 £392.00 £496.00 £888.00 £440.00 £575.00 £1,015.00 7.60 6.8 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 FLXS60B Only available in multi module combinations 0.200 / 0.178 / 0.155 / 0.138 490 1050 200 17 48 / - / 41 / 39 60 Only available in multi module combinations 1.7 48 / 44 62 0.848 / 0.815 £478.00 £722.00 £1,200.00 Accessories: £526.00 see multi section see multi section Notes: Accessory Ref Description Trade Price KRP413A1S KRP928A2S KLIC-DD RTD-RA K.CWB90-2 K.DT1 K.CGS K.CGM Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £78.00 £137.00 £171.00 £157.00 £37.00 £56.00 £223.00 £308.00 Features: i) All fan coils supplied as standard with infrared remote controller ii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C > Can be installed EITHER as ceiling mounted OR wall unit > Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling suspended installation > Home Leave setting maintains pre-set temperature during periods of extended absence > Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible 20 Residential, Commercial and Industrial SPLIT, SKY AIR HEAT PUMPS FNQ-A / RXS-L Concealed Floor Standing Indoor Units Vertical Ducted Capacity Seasonal Efficiency (EN14825 COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) External Static Pressure Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low High / Nominal Height (with legs) Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High kW kW kW kW kW kWh kW kWh kWh m3/sec Pa mm mm mm kg dBA dBA mm kg FNQ25A FNQ35A FNQ50A FNQ60A 2.54 1.89 2.40 3.20 A+ 2.60 5.63 162 A+ 2.80 4.24 925 3.77 / 4.00 A/A 345 0.145 / 0.133 / 0.122 3.32 2.26 3.40 4.00 A+ 3.40 5.65 211 A+ 2.90 4.05 1002 3.06 / 3.48 B/B 556 0.145 / 0.133 / 0.122 4.89 3.66 5.00 5.80 A+ 5.00 5.72 306 A+ 4.00 4.09 1369 3.35 / 3.34 A/C 746 0.267 / 0.247 / 0.225 5.86 4.11 6.00 7.00 A 6.00 5.51 381 A+ 4.60 4.16 1548 2.68 / 3.11 D/D 1119 0.225 / 0.247 / 0.025 48 / 30 620 (720) 750 200 23 33 / 31 / 28 53 49 / 40 620 (720) 1150 200 30 36 / 33 / 30 56 RXS25L3 550 x 765 x 285 34 RXS35L3 550 x 765 x 285 34 2.90 3.3 10 4.70 4.3 10 RXS50L 735 x 825 x 300 47 RXS60L 735 x 825 x 300 48 6.30 6.8 20 9.40 10.2 20 1ph A A A inches (mm) m m m g/m kg dBA dBA m3/sec Trade Fan Coil Price Trade Condensing Unit Price Total System Price 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 20 15 10 20 15 10 30 20 10 30 20 10 1.0 46 / 43 59 0.558 1.2 48 / 44 61 0.600 1.7 48 / 44 61 0.848 1.5 49 / 46 62 0.836 £424.00 £496.00 £920.00 £524.00 £575.00 £1,099.00 £610.00 £722.00 £1,332.00 £672.00 £770.00 £1,442.00 20 Accessories: Notes: Accessory Ref Description Trade Price BRC4C65 BRC2E53C Wireless remote controller Wired Simplified remote controller (without auto swing) Recessed simplified remote (see page 100 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £158.00 £83.00 £188.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £56.00 £223.00 £308.00 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.DT1 K.CGS K.CGM i) Fan-coils supplied with BRC1E53A hard wired remote ii) All fan coil units standard with auto restart after power failure iii) Fan-coils supplied as standard with air filter iv) FNQ-A supplied with 100mm high legs for optional mounting v) Minimum ambient operating temperature: RXS Cooling Heating -10°C -15°C Features: > > > > > Requires very little installation space Low height makes it ideal for installation beneath window Connect to multi for residential solution Connect to Sky Air for twin, triple or double applications External static pressure of up to 49Pa Price List Update: Valid from 1st January 2017 21 SPLIT, SKY AIR HEAT PUMPS FVQ-C / RZQG-L Floor Standing – Seasonal Smart Indoor Units Single Phase FVQ71C Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions FVQ100C FVQ125C 3 Phase FVQ140C FVQ71C FVQ100C Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nominal mm kg 990 x 940 x 320 69 1430 x 940 x 320 95 A A A 8.26 4 20 10.18 4 32 1430 x 940 x 320 95 1430 x 940 x 320 95 990 x 940 x 320 80 1430 x 940 x 320 101 15.29 4 32 17.04 4 32 3.11 4 16 3.83 4 20 1ph inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible 50 30 30 2.9 48 / 43 64 0.983 £1,039.00 £1,239.00 £2,278.00 1430 x 940 x 320 101 1430 x 940 x 320 101 5.75 4 20 6.41 4 20 3ph 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 / 45 51 / 45 66 67 1.166 1.166 75 30 30 50 30 30 4.0 52 / 45 69 1.400 2.9 48 / 43 64 0.983 ● Trade Fan Coil Price Trade Condensing Unit Price Total System Price 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 / 45 51 / 45 66 67 1.166 1.166 75 30 30 4.0 52 / 45 69 1.400 ● £1,142.00 £1,575.00 £2,717.00 £1,260.00 £1,733.00 £2,993.00 £1,355.00 £1,978.00 £3,333.00 £1,039.00 £1,277.00 £2,316.00 Accessories: £1,142.00 £1,648.00 £2,790.00 £1,260.00 £1,813.00 £3,073.00 £1,355.00 £2,083.00 £3,438.00 Notes: Accessory Ref Description Trade Price KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £96.00 £198.00 £245.00 £262.00 £193.00 £37.00 £47.00 £61.00 £308.00 £369.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) All fan coil units standard with auto restart after power failure iii) Minimum ambient operating temperatures: RZQG RZQSG Features: Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms A wired BRC1E53A remote controller is mounted on the front of the unit (standard) Controllable horizontal air-blow patterns, via remote control Very efficient for use in rooms with high ceilings Fan speed: 2 fan speeds can be selected, high or low Re-use of existing R22 and R407C piping possible Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) DIII net compatibility as standard 22 FVQ140C RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 Height x Width x Depth Weight Electrical Details > > > > > > > > > > FVQ125C 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50 A++ A+ A+ A++ A+ A+ 6.80 9.50 12.00 6.80 9.50 12.00 6.31 5.61 5.61 6.31 5.61 5.61 378 593 749 378 593 749 A+ A+ A A+ A+ A 6.33 11.30 11.30 6.33 11.30 11.30 4.05 4.20 3.87 4.05 4.20 3.87 2189 3767 4088 2189 3767 4088 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61 A/A A/A A/A A/A A/A A/A A/A A/A 1010 1245 1870 2085 1010 1245 1870 2085 0.300 / 0.267 / 0.467 / 0.417 / 0.467 / 0.433 / 0.500 / 0.467 / 0.300 / 0.267 / 0.467 / 0.417 / 0.467 / 0.433 / 0.500 / 0.467 / 0.233 0.367 0.400 0.433 0.233 0.367 0.400 0.433 1850 1850 1850 1850 1850 1850 1850 1850 600 600 600 600 600 600 600 600 270 350 350 350 270 350 350 350 39 47 47 47 39 47 47 47 43 / 41 / 38 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48 43 / 41 / 38 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48 55 62 63 65 55 62 63 65 Residential, Commercial and Industrial Cooling Heating -15°C -15°C -20°C -15°C SPLIT, SKY AIR HEAT PUMPS FVQ-C / RZQSG-L Floor Standing – Seasonal Classic Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details 3 Phase FVQ71C FVQ100C FVQ125C FVQ140C FVQ100C FVQ125C FVQ140C 7.28 4.99 6.80 7.50 A 6.80 5.50 433 A 6.33 3.86 2296 3.21 / 3.61 A/A 1059 0.300 / 0.267 / 0.233 1850 600 270 39 43 / 41 / 38 55 10.80 7.44 9.50 10.80 A 9.50 5.50 605 A+ 7.60 4.01 2654 3.21 / 3.61 A/A 1480 0.467 / 0.417 / 0.367 1850 600 350 47 50 / 47 / 44 62 13.60 9.30 12.00 13.50 A 12.00 5.50 764 A 7.60 3.85 2764 2.81 / 3.41 C/B 2135 0.467 / 0.433 / 0.400 1850 600 350 47 51 / 48 / 46 60 14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 0.500 / 0.467 / 0.433 1850 600 350 47 53 / 51 / 48 63 10.80 7.44 9.50 10.80 A 9.50 5.50 605 A+ 7.60 4.01 2654 3.21 / 3.61 A/A 1480 0.467 / 0.417 / 0.367 1850 600 350 47 50 / 47 / 44 59 13.60 9.30 12.00 13.50 A 12.00 5.50 764 A 7.60 3.85 2764 2.81 / 3.41 C/B 2135 0.467 / 0.433 / 0.400 1850 600 350 47 51 / 48 / 46 60 14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 0.500 / 0.467 / 0.433 1850 600 350 47 53 / 51 / 48 63 RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec 770 x 900 x 320 72 8.66 4 20 50 15 30 2.75 49 / 49 65 0.833 £1,039.00 £853.00 £1,892.00 990 x 940 x 320 74 1ph 12.10 17.45 4 4 32 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 / 49 54 / 49 70 70 1.266 1.283 £1,142.00 £1,181.00 £2,323.00 £1,260.00 £1,295.00 £2,555.00 1430 x 940 x 320 104 18.19 4 32 50 30 30 4.0 53 / 49 69 1.383 £1,355.00 £1,442.00 £2,797.00 990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.55 6.56 6.84 4 4 4 20 20 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 / 49 54 / 49 53 / 49 70 70 69 1.266 1.283 1.383 £1,142.00 £1,217.00 £2,359.00 £1,260.00 £1,334.00 £2,594.00 £1,355.00 £1,486.00 £2,841.00 Price List Update: Valid from 1st January 2017 23 SPLIT, SKY AIR HEAT PUMPS FHQ-CB / RZQG-L Ceiling Suspended – Seasonal Smart Indoor Units Single Phase FHQ71CB Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power (Cooling) Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nominal kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA FHQ100CB 3 Phase FHQ125CB FHQ140CB FHQ71CB FHQ100CB FHQ125CB RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320 69 95 80 101 1ph 3ph A 7.27 10.18 14.63 16.55 2.74 3.83 5.50 6.23 A 4 4 4 4 4 4 4 4 A 20 32 32 32 16 20 20 20 3+E / 1.5 3+E / 1.5 inches (mm) 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9) m 50 75 75 75 50 75 75 75 m 30 30 30 30 30 30 30 30 m 30 30 30 30 30 30 30 30 g/m Refer to Installation Manual Refer to Installation Manual kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 dBA 48 / 43 50 / 45 51 / 45 52 / 45 48 / 43 50 / 45 51 / 45 52 / 45 dBA 64 66 67 69 64 66 67 69 m3/sec 0.983 1.166 1.166 1.400 0.983 1.166 1.166 1.400 mm kg ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price ● ● ● £963.00 £1,239.00 £2,202.00 £1,023.00 £1,575.00 £2,598.00 £1,279.00 £1,733.00 £3,012.00 £1,518.00 £1,978.00 £3,496.00 ● ● ● £963.00 £1,277.00 £2,240.00 £1,023.00 £1,648.00 £2,671.00 £1,279.00 £1,813.00 £3,092.00 Accessories: £1,518.00 £2,083.00 £3,601.00 Notes: Accessory Ref Description Trade Price BRC7G53 EKRORO4 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.CWB140-2 K.DT2 K.CGS K.CGM K.CGL KDDQ50A140 KAFP501A80 KAFP501A160 Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ Fresh air intake kit for up to 20% fresh air Long life filter for 71 Class Long Life filter for 100, 125 & 140 Class £158.00 £30.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £47.00 £61.00 £223.00 £308.00 £369.00 £165.00 £121.00 £155.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7GA53 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG RZQSG Features: > Suitable for ceiling heights of up to 3.8m without loss of capacity > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology > Forced off: The optional forced off enables the unit to switch off automatically, for example when a window is opened > Re-use of existing R22 and R407C piping possible 24 FHQ140CB 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50 A++ A++ A+ A++ A++ A+ 6.80 9.50 12.00 6.80 9.50 12.00 6.86 6.11 6.01 6.95 6.11 6.01 347 545 699 347 545 699 A+ A++ A+ A+ A++ A+ 7.60 11.30 14.13 7.60 11.30 14.13 4.32 4.61 4.23 4.32 4.61 4.23 2463 3431 4677 2462 3431 4677 3.82 / 4.13 3.81 / 4.15 3.52 / 3.89 3.31 / 3.63 3.82 / 4.13 3.81 / 4.15 3.52 / 3.89 3.31 / 3.63 A/A A/A A/A A/A A/A A/A A/A A/A 890 1245 1790 2025 890 1245 1790 2025 0.342 / 0.283 / 0.467 / 0.400 / 0.517 / 0.450 / 0.567 / 0.483 / 0.342 / 0.283 / 0.467 / 0.400 / 0.517 / 0.450 / 0.567 / 0.483 / 0.233 0.333 0.383 0.400 0.233 0.333 0.383 0.400 235 235 235 235 235 235 235 235 1270 1590 1590 1590 1270 1590 1590 1590 690 690 690 690 690 690 690 690 32 38 38 38 32 38 38 38 38 / 36 / 34 42 / 38 / 34 44 / 41 / 37 46 / 42 / 38 38 / 36 / 34 42 / 38 / 34 44 / 41 / 37 46 / 42 / 38 55 60 62 64 55 60 62 64 Residential, Commercial and Industrial > Suitable for Twin, Triple and Double Twin applications > Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard Cooling Heating -15°C -15°C -20°C -15°C SPLIT, SKY AIR HEAT PUMPS FHQ-CB / RZQSG-L Ceiling Suspended – Seasonal Classic Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power (Cooling) kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details 3 Phase FHQ71CB FHQ100CB FHQ125CB FHQ140CB FHQ100CB FHQ125CB FHQ140CB 7.28 4.99 6.80 7.50 A+ 6.80 5.61 425 A 7.60 3.90 2727 3.46 / 4.00 A/A 983 0.342 / 0.283 / 0.233 235 1270 690 32 38 / 36 / 34 55 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A 7.60 3.91 2722 3.21 / 3.61 A/A 1480 0.467 / 0.400 / 0.333 235 1590 690 38 42 / 38 / 34 60 13.60 9.30 12.00 13.50 A+ 12.00 5.61 749 A+ 7.60 4.01 2654 2.89 / 3.62 C/A 2075 0.517 / 0.450 / 0.383 235 1590 690 38 44 / 41 / 37 62 14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 0.567 / 0.483 / 0.400 235 1590 690 38 46 / 42 / 38 64 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A 7.60 3.91 2722 3.21 / 3.61 A/A 1480 0.467 / 0.400 / 0.333 235 1590 690 38 42 / 38 / 34 60 13.60 9.30 12.00 13.50 A+ 12.00 5.61 749 A+ 7.60 4.01 2654 2.89 / 3.62 C/A 2075 0.517 / 0.450 / 0.383 235 1590 690 38 44 / 41 / 37 62 14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 0.567 / 0.483 / 0.400 235 1590 690 38 46 / 42 / 38 64 RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg 770 x 900 x 320 67 72 990 x 940 x 320 8.05 4 20 12.10 4 32 74 1430 x 940 x 320 95 16.96 4 32 18.19 4 32 1ph A A A inches (mm) m m m g/m kg dBA dBA m3/sec 50 15 30 2.75 49 / 49 65 0.866 £963.00 £853.00 £1,816.00 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 / 49 54 / 49 70 70 1.266 1.283 £1,023.00 £1,181.00 £2,204.00 £1,279.00 £1,295.00 £2,574.00 50 30 30 4.0 53 / 49 69 1.383 £1,518.00 £1,442.00 £2,960.00 990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.52 6.34 6.80 4 4 4 20 20 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 / 49 54 / 49 53 / 49 70 70 69 1.266 1.283 1.383 £1,023.00 £1,217.00 £2,240.00 £1,279.00 £1,334.00 £2,613.00 £1,518.00 £1,486.00 £3,004.00 Price List Update: Valid from 1st January 2017 25 SPLIT, SKY AIR HEAT PUMPS FHQ-CB / RXS-L Ceiling Suspended Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible FHQ35CB FHQ50CB FHQ60CB 3.32 2.58 3.40 4.00 A++ 3.40 6.18 193 A+ 3.10 4.43 981 3.58 / 4.08 A/A 475 0.233 / 0.192 / 0.167 235 960 690 24 36 / 34 / 31 53 4.92 3.52 5.00 6.00 A+ 5.00 5.87 298 A 4.35 3.86 1578 3.18 / 3.35 B/C 785 0.250 / 0.200 / 0.167 235 960 690 25 37 / 35 / 32 54 5.57 3.93 5.70 7.20 A+ 5.70 6.02 332 A 4.71 3.87 1705 3.26 / 3.32 A/C 875 0.325 / 0.250 / 0.250 235 1270 690 31 37 / 35 / 33 54 RXS35L3 RXS50L RXS60L 550 x 765 x 285 34 735 x 825 x 300 47 1ph 7.3 6.8 20 735 x 825 x 300 48 4.1 4.3 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 1.2 48 / 44 61 0.600 7.8 10.2 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 20.0 1.7 48 / 44 62 0.848 30 20 10 1.5 49 / 46 62 0.836 £751.00 £722.00 £1,473.00 £824.00 £770.00 £1,594.00 ● Trade Fan Coil Price Trade Condensing Unit Price Total System Price £693.00 £575.00 £1,268.00 Accessories: Notes: Accessory Ref Description Trade Price BRC7G53 EKRORO4 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.DT1 K.CGS K.CGM KDDQ50A140 KAFP501A80 KAFP501A160 Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. Energy control PCB for Sky Air and VRV. KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 Fresh air intake kit for up to 20% fresh air Long life filter for 71 Class Long Life filter for 100, 125 & 140 Class £158.00 £30.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £56.00 £223.00 £308.00 £165.00 £121.00 £155.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7GA53 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RXS Features: > > > > > Suitable for ceiling heights of up to 3.8m without loss of capacity Vertical auto-swing function of flaps ensures efficient air and temperature distribution Forced off: The optional forced off feature enables the unit to switch off automatically, for example when a window is opened Re-use of existing R22 and R407C piping possible Suitable for Twin, Triple and Double Twin applications 26 Residential, Commercial and Industrial Cooling Heating -10°C -15°C Refrigerant Indoor Model Ururu Sarara Emura (Silver) R32 Wall Mount Emura (White) FTXM (Standard Inverter) Emura (Silver) Emura (White) FTXS (Standard Inverter) Wall Mount FTX (Low Inverter) Smart Single Phase Smart Three Phase Classic Single Phase Classic Three Phase Nexura (Stylish Floor Standing Cased) FVXS (Floor Standing Cased) Smart Single Phase R410A Smart Three Phase Floor Standing Classic Single Phase Classic Three Phase Flexi (FLXS) Concealed Floor Standing (FNQ) Smart Single Phase Smart Three Phase Ceiling Suspended Classic Single Phase Classic Three Phase RXS Capacity 2.5kW 3.5kW 5.0kW 2.0kW 2.5kW 3.5kW 5.0kW 2.0kW 2.5kW 3.5kW 5.0kW 2.0kW 2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW 2.0kW 2.5kW 3.5kW 5.0kW 2.0kW 2.5kW 3.5kW 5.0kW 2.0kW 2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW 2.0kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 7.1kW 10.0kW 7.1kW 10.0kW 7.1kW 10.0kW 10.0kW 2.5kW 3.5kW 5.0kW 2.5kW 3.5kW 5.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 10.0kW 12.5kW 14.0kW 2.5kW 3.5kW 5.0kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 10.0kW 12.5kW 14.0kW 3.5kW 5.0kW 6.0kW Order Code SB.FTXZ25N/RXZN SB.FTXZ35N/RXZN SB.FTXZ50N/RXZN SB.FTXJ20MS/RXJM SB.FTXJ25MS/RXJM SB.FTXJ35MS/RXJM SB.FTXJ50MS/RXJM SB.FTXJ20MW/RXJM SB.FTXJ25MW/RXJM SB.FTXJ35MW/RXJM SB.FTXJ50MW/RXJM SB.FTXM20M/RXMM SB.FTXM25M/RXMM SB.FTXM35M/RXMM SB.FTXM42M/RXMM SB.FTXM50M/RXMM SB.FTXM60M/RXMM SB.FTXM71M/RXMM SB.FTXG20LS_WIFI/R SB.FTXG25LS_WIFI/R SB.FTXG35LS_WIFI/R SB.FTXG50LS_WIFI/R SB.FTXG20LW_WIFI/R SB.FTXG25LW_WIFI/R SB.FTXG35LW_WIFI/R SB.FTXG50LW_WIFI/R SB.FTXS20K/RXSL3 SB.FTXS25K/RXSL3 SB.FTXS35K/RXSL3 SB.FTXS42K/RXSL SB.FTXS50K/RXSL SB.FTXS560G/RXSL SB.FTXS71G/RXSF8 SB.FTX20KV/RXK SB.FTX25KV/RXK SB.FTX35KV/RXK SB.FTX50KV/RXK SB.FTX60KV/RXK SB.FTX71KV/RXK SB.FAQ71C9_F/GLV SB.FAQ100C9_F/GLV SB.FAQ71C9_F/GLY SB.FAQ100C9_F/GLY SB.FAQ71C9_F/SLV SB.FAQ100C9_F/SLV SB.FAQ100C9_F/SLY SB.FVXG25K/RXGL SB.FVXG35K/RXGL SB.FVXG50K/RXGL SB.FVXS25F/RXSL3 SB.FVXS35F/RXSL3 SB.FVXS50F/RXSL SB.FVQ71C_F/GLV SB.FVQ100C_F/GLV SB.FVQ125C_F/GLV SB.FVQ140C_F/GLV SB.FVQ71C_F/GLY SB.FVQ100C_F/GLY SB.FVQ125C_F/GLY SB.FVQ140C_F/GLY SB.FVQ71C_F/SLV SB.FVQ100C_F/SLV SB.FVQ125C_F/SLV SB.FVQ140C_F/SLV SB.FVQ100C_F/SLY SB.FVQ125C_F/SLY SB.FVQ140C_F/SLY SB.FLXS25B/RXSL3 SB.FLXS35B9/RXSL3 SB.FLXS50B/RXSL SB.FNQ25A_F/RXSL3 SB.FNQ35A_F/RXSL3 SB.FNQ5OA_F/RXSL SB.FNQ60A_F/RXSL SB.FHQ71CB_F/GLV SB.FHQ100CB_F/GLV SB.FHQ125CB_F/GLV SB.FHQ140CB_F/GLV SB.FHQ71CB_F/GLY SB.FHQ100CB_F/GLY SB.FHQ125CB_F/GLY SB.FHQ140CB_F/GLY SB.FHQ71CB_F/SLV SB.FHQ100CB_F/SLV SB.FHQ125CB_F/SLV SB.FHQ140CB_F/SLV SB.FHQ100CB_F/SLY SB.FHQ125CB_F/SLY SB.FHQ140CB_F/SLY SB.FHQ35CB_F/RXSL3 SB.FHQ5OCB_F/RXSL SB.FHQ60CB_F/RXSL Product Codes Included FTXZ25N x 1 & RXZ25N x 1 FTXZ35N x 1 & RXZ35N x 1 FTXZ50N x 1 & RXZ50N x 1 RXJ20M & FTXJ20MS RXJ25M & FTXJ25MS RXJ35M & FTXJ35MS RXJ50M & FTXJ50MS RXJ20M & FTXJ20MW RXJ25M & FTXJ25MW RXJ35M & FTXJ35MW RXJ50M & FTXJ50MW RXM20M & FTXM20M RXM25M & FTXM25M RXM35M & FTXM35M RXM42M & FTXM42M RXM50M & FTXM50M RXM60M & FTXM60M RXM71M & FTXM71M BRP069A41 x 1 & FTXG20LS x 1 & RXG20L x 1 BRP069A41 x 1 & FTXG25LS x 1 & RXG25L x 1 BRP069A41 x 1 & FTXG35LS x 1 & RXG35L x 1 BRP069A41 x 1 & FTXG50LS x 1 & RXG50L x 1 BRP069A41 x 1 & FTXG20LW x 1 & RXG20L x 1 BRP069A41 x 1 & FTXG25LW x 1 & RXG25L x 1 BRP069A41 x 1 & FTXG35LW x 1 & RXG35L x 1 BRP069A41 x 1 & FTXG50LW x 1 & RXG50L x 1 FTXS20K x 1 & RXS20L3 x 1 FTXS25K x 1 & RXS25L3 x 1 FTXS35K x 1 & RXS35L3 x 1 FTXS42K x 1 & RXS42L x 1 FTXS50K x 1 & RXS50L x 1 FTXS60G x 1 & RXS60L x 1 FTXS71G x 1 & RXS71F8 x 1 RX20K & FTX20KV RX25K & FTX25KV RX35K & FTX35KV RX50K & FTX50KV RX60K & FTX60KV RX71K & FTX71KV BRC1E53A x 1 & FAQ71C x 1 & RZQG71L9V1 x 1 BRC1E53A x 1 & FAQ100C x 1 & RZQG100L9V1 x 1 BRC1E53A x 1 & FAQ71C x 1 & RZQG71L8Y1 x 1 BRC1E53A x 1 & FAQ100C x 1 & RZQG100L8Y1 x 1 BRC1E53A x 1 & FAQ71C x 1 & RZQSG71L3V1 x 1 BRC1E53A x 1 & FAQ100C x 1 & RZQSG100L9V1 x 1 BRC1E53A x 1 & FAQ100C x 1 & RZQSG100L8Y1 x 1 FVXG25K x 1 & RXG25L x 1 FVXG35K x 1 & RXG35L x 1 FVXG50K x 1 & RXG50L x 1 FVXS25F x 1 & RXS25L3 x 1 FVXS35F x 1 & RXS35L3 x 1 FVXS50F x 1 & RXS50L x 1 BRC1E53A x 1 & FVQ71C x 1 & RZQG71L9V1 x 1 BRC1E53A x 1 & FVQ100C x 1 & RZQG100L9V1 x 1 BRC1E53A x 1 & FVQ125C x 1 & RZQG125L9V1 x 1 BRC1E53A x 1 & FVQ140C x 1 & RZQG140L9V1 x 1 BRC1E53A x 1 & FVQ71C x 1 & RZQG71L8Y1 x 1 BRC1E53A x 1 & FVQ100C x 1 & RZQG100L8Y1 x 1 BRC1E53A x 1 & FVQ125C x 1 & RZQG125L8Y1 x 1 BRC1E53A x 1 & FVQ140C x 1 & RZQG140LY1 x 1 BRC1E53A x 1 & FVQ71C x 1 & RZQSG71L3V1 x 1 BRC1E53A x 1 & FVQ100C x 1 & RZQSG100L9V1 x 1 BRC1E53A x 1 & FVQ125C x 1 & RZQSG125L9V1 x 1 BRC1E53A x 1 & FVQ140C x 1 & RZQSG140L9V1 x 1 BRC1E53A x 1 & FVQ100C x 1 & RZQSG100L8Y1 x 1 BRC1E53A x 1 & FVQ125C x 1 & RZQSG125L8Y1 x 1 BRC1E53A x 1 & FVQ140C x 1 & RZQSG140LY1 x 1 FLXS25B x 1 & RXS25L3 x 1 FLXS35B9 x 1 & RXS35L3 x 1 FLXS50B x 1 & RXS50L x 1 BRC1E53A x 1 & FNQ25A x 1 & RXS25L3 x 1 BRC1E53A x 1 & FNQ35A x 1 & RXS35L3 x 1 BRC1E53A x 1 & FNQ50A x 1 & RXS50L x 1 BRC1E53A x 1 & FNQ60A x 1 & RXS60L x 1 BRC1E53A x 1 & FHQ71CB x 1 & RZQG71L9V1 x 1 BRC1E53A x 1 & FHQ100CB x 1 & RZQG100L9V1 x 1 BRC1E53A x 1 & FHQ125CB x 1 & RZQG125L9V1 x 1 BRC1E53A x 1 & FHQ140CB x 1 & RZQG140L9V1 x 1 BRC1E53A x 1 & FHQ71CB x 1 & RZQG71L8Y1 x 1 BRC1E53A x 1 & FHQ100CB x 1 & RZQG100L8Y1 x 1 BRC1E53A x 1 & FHQ125CB x 1 & RZQG125L8Y1 x 1 BRC1E53A x 1 & FHQ140CB x 1 & RZQG140LY1 x 1 BRC1E53A x 1 & FHQ71CB x 1 & RZQSG71L3V1 x 1 BRC1E53A x 1 & FHQ100CB x 1 & RZQSG100L9V1 x 1 BRC1E53A x 1 & FHQ125CB x 1 & RZQSG125L9V1 x 1 BRC1E53A x 1 & FHQ140CB x 1 & RZQSG140L9V1 x 1 BRC1E53A x 1 & FHQ100CB x 1 & RZQSG100L8Y1 x 1 BRC1E53A x 1 & FHQ125CB x 1 & RZQSG125L8Y1 x 1 BRC1E53A x 1 & FHQ140CB x 1 & RZQSG140LY1 x 1 BRC1E53A x 1 & FHQ35CB x 1 & RXS35L3 x 1 BRC1E53A x 1 & FHQ50CB x 1 & RXS50L x 1 BRC1E53A x 1 & FHQ60CB x 1 & RXS60L x 1 List Price £1,335.00 £1,551.00 £1,741.00 £866.00 £912.00 £1,044.00 £1,397.00 £811.00 £854.00 £980.00 £1,311.00 £646.00 £700.00 £811.00 £914.00 £1,082.00 £1,137.00 £1,544.00 £864.00 £908.00 £1,033.00 £1,369.00 £811.00 £853.00 £972.00 £1,287.00 £614.00 £668.00 £772.00 £869.00 £1,028.00 £1,082.00 £1,470.00 £445.00 £480.00 £555.00 £768.00 £808.00 £1,137.00 £2,018.00 £2,416.00 £2,056.00 £2,489.00 £1,632.00 £2,022.00 £2,058.00 £1,182.00 £1,316.00 £1,595.00 £1,040.00 £1,162.00 £1,363.00 £2,278.00 £2,717.00 £2,993.00 £3,333.00 £2,316.00 £2,790.00 £3,073.00 £3,438.00 £1,892.00 £2,323.00 £2,555.00 £2,797.00 £2,359.00 £2,594.00 £2,841.00 £888.00 £1,015.00 £1,200.00 £920.00 £1,099.00 £1,332.00 £1,442.00 £2,202.00 £2,598.00 £3,012.00 £3,496.00 £2,240.00 £2,671.00 £3,092.00 £3,601.00 £1,816.00 £2,204.00 £2,574.00 £2,960.00 £2,240.00 £2,613.00 £3,004.00 £1,268.00 £1,473.00 £1,594.00 Price List Update: Valid from 1st January 2017 27 SPLIT, SKY AIR HEAT PUMPS To simplify the order process, you may want to use the Order Code from table below. Each code includes all products for a system (eg remote controllers, indoor units) & means you no longer need to order individual materials. SPLIT, SKY AIR HEAT PUMPS FCQHG-F / RZQG-L High COP Roundflow Cassette – Seasonal Smart Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Dimensions (with Decoration Panel) kW kW kW kW kW kWh kW kWh kWh m3/sec Single Phase 3 Phase FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG71F FCQHG100F FCQHG125F FCQHG140F 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50 A++ A++ A++ A++ A++ A++ 6.80 9.50 12.00 6.80 9.50 12.00 7.00 7.00 6.61 7.00 7.00 6.61 340 475 636 340 475 636 A+ A++ A++ A+ A++ A++ 7.60 11.30 12.66 7.60 11.30 12.66 4.54 4.80 4.63 4.54 4.80 4.63 2344 3296 3829 2344 3296 3829 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.12 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.14 A/A A/A A/A A/A A/A A/A A/A A/A 830 1075 1500 2000 830 1075 1500 2000 0.353 / 0.270 / 0.538 / 0.428 / 0.558 / 0.445 / 0.558 / 0.455 / 0.353 / 0.270 / 0.538 / 0.428 / 0.558 / 0.445 / 0.558 / 0.455 / 0.203 0.317 0.332 0.352 0.203 0.317 0.332 0.352 288(348) 288 (348) 288 (348) 288 (348) 288(348) 288 (348) 288 (348) 288 (348) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 25 (30.4) 26 (31.4) 26 (31.4) 26 (31.4) 25 (30.4) 26 (31.4) 26 (31.4) 26 (31.4) 36 / 33 / 29 44 / 39 / 33 45 / 40 / 35 45 / 41 / 37 36 / 33 / 29 44 / 39 / 33 45 / 40 / 35 45 / 41 / 37 53 61 61 61 53 61 61 61 Height Width Depth Weight (with Decoration Panel) Sound Pressure (Cooling) High / Nom / Low Sound Power mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320 69 95 80 101 1ph 3ph A 6.78 8.79 12.26 16.35 2.55 3.31 4.61 6.15 A 4 4 4 4 4 4 4 4 A 20 32 32 32 16 20 20 20 3+E / 1.5 3+E / 1.5 inches (mm) 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9) m 50 75 75 75 50 75 75 75 m 30 30 30 30 30 30 30 30 m 30 30 30 30 30 30 30 30 g/m Refer to Installation Manual Refer to Installation Manual kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 dBA 48 / 43 50 / 45 51 / 45 52 / 45 48 / 43 50 / 45 51 / 45 52 / 45 dBA 64 66 67 69 64 66 67 69 m3/sec 0.983 1.166 1.166 1.400 0.983 1.166 1.166 1.400 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nom mm kg ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price ● ● ● ● ● ● ● ● £819.00 £1,239.00 £2,058.00 £926.00 £1,575.00 £2,501.00 £1,012.00 £1,733.00 £2,745.00 £1,215.00 £1,978.00 £3,193.00 £819.00 £1,277.00 £2,096.00 £926.00 £1,648.00 £2,574.00 £1,012.00 £1,813.00 £2,825.00 £1,215.00 £2,083.00 £3,298.00 Accessories: Accessory Ref BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDP55C160-1 (suction chamber) KDDQ55B140-2 (connecting chamber) KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL Notes: Description Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit Trade Price £158.00 £323.00 £167.00 £103.00 £94.00 £243.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £47.00 £61.00 £308.00 £369.00 iv) All fan coils suppled as standard with BYCQ140D Decoration panel Features: ii) BRC7FA532F Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £148.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures: RZQG RZQSG AZQS Residential, Commercial and Industrial Heating -20°C -15°C -15°C vii) FCQG-F / FCQHG-F compatible with RZQG / RZQSG viii) FCQG-F / FCQHG-F are same price > The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Optional Fresh Air intake (up to 20%) possible > Suitable for Twin, Triple and Double Twin applications (Smart & Classic) > Re-use of existing R22 and R407C piping possible > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard 28 Cooling -15°C -15°C -5°C SPLIT, SKY AIR HEAT PUMPS FCQG-F / RZQSG-L Compact Roundflow Cassette – Seasonal Classic Indoor Units Single Phase FCQG71F Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate (Cooling) High / Nom / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure (Cooling) High / Nom / Low Sound Power Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High kW kW kW kW FCQG100F 3 Phase FCQG125F FCQG140F FCQG100F FCQG125F FCQG140F 7.28 10.80 13.60 14.90 10.80 13.60 14.90 4.99 7.44 9.30 10.25 7.44 9.30 10.25 6.80 9.50 12.00 13.40 9.50 12.00 13.40 7.50 10.80 13.50 15.50 10.80 13.50 15.50 A++ A++ A A++ A 6.80 9.50 12.00 9.50 12.00 6.10 6.50 5.30 6.50 5.30 390 512 793 512 793 A+ A+ A+ A+ A+ 6.33 7.60 8.03 7.60 8.03 4.10 4.10 4.01 4.10 4.01 2162 2596 2804 2596 2804 3.21 / 3.61 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41 A/A A/B A/B B/B A/B A/B B/B 1060 1440 1870 2225 1440 1870 2225 0.250 / 0.202 / 0.152 0.380 / 0.293 / 0.207 0.433 / 0.320 / 0.207 0.267 / 0.320 / 0.207 0.380 / 0.293 / 0.207 0.433 / 0.320 / 0.207 0.267 / 0.320 / 0.207 246 (306) 246 (306) 246 (306) 246 (306) 246 (306) 204 (264) 246 (306) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 33 / 31 / 28 37 / 33 / 29 41 / 35 / 29 41 / 35 / 29 37 / 33 / 29 41 / 35 / 29 41 / 35 / 29 51 54 58 58 54 58 58 kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320 72 75 95 82 101 1ph 3ph A 8.66 11.77 15.29 18.19 4.40 5.72 6.80 A 4 4 4 4 4 4 4 A 20 32 32 32 20 20 20 3+E / 1.5 3+E / 1.5 inches (mm) 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9) m 50 50 50 50 50 50 50 m 15 30 30 30 30 30 30 m 30 30 30 30 30 30 30 g/m Refer to Installation Manual Refer to Installation Manual kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0 dBA 49 / 49 53 / 49 54 / 49 53 / 49 53 / 49 54 / 49 53 / 49 dBA 65 70 70 69 70 70 69 m3/sec 0.866 1.266 1.283 1.383 1.266 1.283 1.383 mm kg ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price ● ● £819.00 £853.00 £1,672.00 £926.00 £1,181.00 £2,107.00 ● £1,012.00 £1,295.00 £2,307.00 £1,215.00 £1,442.00 £2,657.00 £926.00 £1,217.00 £2,143.00 £1,012.00 £1,334.00 £2,346.00 £1,215.00 £1,486.00 £2,701.00 One cassette, 3 options: Daikin’s Roundflow Cassette range has a solution for all your needs: > Price > Performance > Highest Efficiency > > > > > Pair applications 30m pipe run -5 / -15°C operating range in cooling / heating A/A Energy Labels R22 replacement technology FCQG-F Series cassette BYFQ140D Roundflow decoration panel BRC1E52 remote control > > > > > Pair, twin, triple, double twin applications 50m pipe run -15 / -15°C operating range in cooling / heating A+/A+ Energy Labels R22 replacement technology > > > > > > Pair, twin, triple, double twin applications 75m pipe run -15 / -20°C operating range in cooling / heating Up to A++/A+ Energy Labels All capacities ECA Eligible R22 replacement technology Price List Update: Valid from 1st January 2017 29 SPLIT, SKY AIR HEAT PUMPS FCQG-F / AZQS-B Compact Roundflow Cassette – Seasonal Inverter Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Dimensions (with Decoration Panel) Height Width Depth Weight (with Decoration Panel) Sound Pressure (Cooling) High / Nom / Low Sound Power FCQG100F FCQG125F FCQG140F FCQG100F FCQG125F FCQG140F mm mm mm kg dBA dBA 7.28 4.99 6.80 7.50 A+ 6.80 5.70 418 A 6.33 4.00 2116 B/A 3.11 / 3.61 1093 0.250 / 0.202 / 0.152 204 (264) 840 (950) 840 (950) 21 (26.4) 33 / 31 / 28 51 10.80 7.44 9.50 10.80 A 9.50 5.50 605 A 7.60 3.85 2764 A/B 3.21 / 3.50 1480 0.380 / 0.293 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 33 / 29 54 13.60 9.30 12.10 13.50 B/B 3.10 / 3.41 1952 0.433 / 0.320 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 35 / 29 58 14.90 10.25 13.40 15.50 C/B 2.81 / 3.30 2313 0.267 / 0.320 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 35 / 29 58 10.80 7.44 9.50 10.80 A 9.50 5.50 605 A 7.60 3.85 2764 A/B 3.21 / 3.50 1480 0.380 / 0.293 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 33 / 29 54 13.60 9.30 12.10 13.50 B/B 3.10 / 3.41 1952 0.433 / 0.320 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 35 / 29 58 14.90 10.25 13.40 15.50 C/B 2.81 / 3.30 2313 0.267 / 0.320 / 0.207 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 35 / 29 58 AZQS71BV1 AZQS100B8V1 AZQS125B8V1 AZQS140B8V1 AZQS100BY1 AZQS125BY1 AZQS140BY1 mm kg 770 x 900 x 320 72 kW kW kW kW kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nominal 3 Phase FCQG71F A A A 8.66 4 20 inches (mm) m m m g/m kg dBA dBA m3/sec Trade Fan Coil Price Trade Condensing Unit Price Total System Price 30 15 30 2.75 49 / 43 65 0.866 £819.00 £743.00 £1,562.00 990 x 940 x 320 75 1ph 11.77 15.29 4 4 32 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 30 30 15 15 30 30 Refer to Installation Manual 2.9 2.9 53 / 49 54 / 49 70 70 1.266 1.283 £926.00 £914.00 £1,840.00 1430 x 940 x 320 95 £1,012.00 £1,026.00 £2,038.00 18.19 4 32 30 15 30 4.0 53 / 49 69 1.383 £1,215.00 £1,149.00 £2,364.00 990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.40 5.72 6.80 4 4 4 20 20 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 30 30 30 15 15 15 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 / 49 54 / 49 53 / 49 70 70 69 1.266 1.283 1.383 £926.00 £964.00 £1,890.00 £1,012.00 £1,080.00 £2,092.00 £1,215.00 £1,211.00 £2,426.00 One cassette, 3 options: Daikin’s Roundflow Cassette range has a solution for all your needs: > Price > Performance > Highest Efficiency > > > > > 30 Pair applications 30m pipe run -5 / -15°C operating range in cooling / heating A/A Energy Labels R22 replacement technology Residential, Commercial and Industrial FCQG-F Series cassette BYFQ140D Roundflow decoration panel BRC1E52 remote control > > > > > Pair, twin, triple, double twin applications 50m pipe run -15 / -15°C operating range in cooling / heating A+/A+ Energy Labels R22 replacement technology > > > > > > Pair, twin, triple, double twin applications 75m pipe run -15 / -20°C operating range in cooling / heating Up to A++/A+ Energy Labels All capacities ECA Eligible R22 replacement technology SPLIT, SKY AIR HEAT PUMPS FCQG-F / RXS-L Compact Roundflow Cassette Indoor Units Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate (Cooling) High / Nom / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure (Cooling) High / Nom / Low Sound Power Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec FCQG35F FCQG50F FCQG60F 3.32 2.29 3.40 4.20 A++ 3.50 6.35 193 A++ 3.32 4.90 949 3.74 / 3.5 A/B 455 0.208 / 0.177 / 0.145 204 (264) 840 (950) 840 (950) 18 (23.4) 31 / 29 / 27 49 4.89 3.26 5.00 6.00 A++ 5.00 6.48 270 A++ 4.36 4.29 1426 3.55 / 3.7 A/A 705 0.210 / 0.178 / 0.145 204 (264) 840 (950) 840 (950) 19 (24.4) 31 / 29 / 27 49 5.57 3.67 5.70 7.00 A++ 5.70 6.22 321 A+ 4.71 4.00 1646 3.48 / 3.52 A/B 820 0.227 / 0.187 / 0.145 204 (264) 840 (950) 840 (950) 19 (24.4) 33 / 31 / 28 51 RXS35L3 550 x 765 x 285 34 RXS50L 735 x 825 x 300 47 1ph 6.30 6.80 20 RXS60L 735 x 825 x 300 48 4.00 4.30 10 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 20 15 10 20 1.2 48 / 44 61 0.600 7.40 10.2 20 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 30 20 10 20 1.7 48 / 44 62 0.848 ● ● £711.00 £575.00 £1,286.00 £728.00 £722.00 £1,450.00 Accessories: 30 20 10 20 1.5 49 / 46 62 0.836 £773.00 £770.00 £1,543.00 Notes: Accessory Ref Description Trade Price BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDP55C160-1 (suction chamber) KDDQ55B140-2 (connecting chamber) KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.DT1 K.CGM Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit £158.00 £323.00 £167.00 £103.00 £94.00 £243.00 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 42-71 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £56.00 £308.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7FA532F Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £148.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C Features: > FCQG is a compact cassette designed to suit installation in narrower ceiling voids > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Suitable for Twin, Triple and Double Twin applications > Re-use of existing R22 and R407C piping possible > DIII net compatibility as standard Price List Update: Valid from 1st January 2017 31 SPLIT, SKY AIR HEAT PUMPS FUQ-C / RZQG-L Under Ceiling Cassette – Seasonal Smart Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power FUQ100C FUQ125C FUQ71C FUQ100C FUQ125C mm mm mm kg dBA dBA 7.76 5.32 6.80 7.50 A++ 6.80 6.50 367 A+ 7.60 4.20 2534 4.05 / 4.08 A/A 840 0.383 / 0.325 / 1.933 198 950 950 25 41 / 38 / 35 59 10.80 7.44 9.50 10.80 A++ 9.50 6.11 545 A+ 11.30 4.50 3516 3.86 / 3.95 A/A 1230 0.517 / 0.425 / 0.333 198 950 950 26 46 / 42 / 39 64 13.60 9.30 12.00 13.50 A+ 12.00 5.61 749 A+ 14.13 4.44 4456 3.39 / 3.42 A/A 1770 0.542 / 0.442 / 0.342 198 950 950 26 47 / 43 / 40 65 7.76 5.32 6.80 7.50 A++ 6.80 6.50 367 A+ 7.60 4.20 2534 4.05 / 4.08 A/A 840 0.383 / 0.325 / 1.933 198 950 950 25 41 / 38 / 35 59 10.80 7.44 9.50 10.80 A++ 9.50 6.11 545 A+ 11.30 4.50 3516 3.86 / 3.95 A/A 1230 0.517 / 0.425 / 0.333 198 950 950 26 46 / 42 / 39 64 13.60 9.30 12.00 13.50 A+ 12.00 5.61 749 A+ 14.13 4.44 4456 3.39 / 3.42 A/A 1770 0.542 / 0.442 / 0.342 198 950 950 26 47 / 43 / 40 65 RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 mm kg 990 x 940 x 320 69 kW kW kW kW kW kWh kW kWh kWh m3/sec Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) Nom 3 Phase FUQ71C A A A inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price 1430 x 940 x 320 95 2.9 48 / 43 64 0.983 1ph 9.52 4 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 30 30 Refer to Installation Manual 4.0 50 / 45 66 1.166 ● ● £892.00 £1,239.00 £2,131.00 £978.00 £1,575.00 £2,553.00 6.83 4 20 50 30 30 990 x 940 x 320 80 14.06 4 32 2.57 4 16 75 30 30 50 30 30 4.0 51 / 45 67 1.166 2.9 48 / 43 64 0.983 3ph 3.58 4 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 30 30 Refer to Installation Manual 4.0 50 / 45 66 1.166 ● ● £892.00 £1,277.00 £2,169.00 £978.00 £1,648.00 £2,626.00 £1,079.00 £1,733.00 £2,812.00 Accessories: 5.29 4 20 75 30 30 4.0 51 / 45 67 1.166 £1,079.00 £1,813.00 £2,892.00 Notes: Accessory Ref Description Trade Price BRC7C58 EKRORO5 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £158.00 £30.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £47.00 £61.00 £308.00 £369.00 Features: > The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology > Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit to be installed in a corner or small room > 3 step fan-speed > Suitable for Twin, Triple and Double Twin applications > Re-use of existing R22 and R407C piping possible > Comms, computer and server room cooling possible with EDP setting > Selectable evaporating & condensing temperature for greater operating efficiency 32 1430 x 940 x 320 101 Residential, Commercial and Industrial i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC7C58 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG Cooling Heating -15°C -20°C FOR 2016 FUQ-C / RZQSG-L Under Ceiling Cassette – Seasonal Classic Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate Dimensions Weight Sound Pressure Sound Power Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low kW kW kW kW kW kWh kW kWh kWh m3/min mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Interconnection Wiring Piping Connections Pipework Sound Pressure Sound Power Air Flow Rate (Cooling) SPLIT, SKY AIR HEAT PUMPS NEW Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Nom / Night Quiet High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches m m m g/m kg dBA dBA m3/Sec 3 Phase FUQ71C FUQ100C FUQ125C FUQ100C FUQ125C 7.28 4.99 6.80 7.50 A+ 6.80 5.81 410 A+ 6.33 3.90 2273 3.21 / 3.61 A/A 1060 0.383 / 0.325 / 0.193 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 7.60 4.01 2653 3.21 / 3.61 A/A 1480 0.517 / 0.425 / 0.333 198 950 950 13.60 9.30 12.00 13.50 A 12.0 5.30 793 A 7.60 3.85 2763 2.65 / 3.41 D/B 2265 0.542 / 0.442 / 0.342 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 7.60 4.01 2653 3.21 / 3.61 A/A 1480 0.517 / 0.425 / 0.333 13.60 9.30 12.00 13.50 A 12.0 5.30 793 A 7.60 3.85 2763 2.65 / 3.41 D/B 2265 0.542 / 0.442 / 0.342 198 950 950 26 25 41 / 38 / 35 59 46 / 42 / 39 64 47 / 43 / 40 65 46 / 42 / 39 64 47 / 43 / 40 65 RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG100L8Y1 RZQSG125L8Y1 770 x 900 x 320 67 26 990 x 940 x 320 2.75 49 / 49 65 0.866 72 1ph 11.32 4 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 30 30 Refer to Installation Manual 2.9 53 / 49 70 1.266 2.9 54 / 49 70 1.283 £892.00 £853.00 £1,745.00 £978.00 £1,181.00 £2,159.00 £1,079.00 £1,295.00 £2,374.00 8.32 4 20 50 15 30 990 x 940 x 320 82 3ph 74 16.46 4 32 4.22 4 20 5.90 4 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 30 30 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 / 49 54 / 49 70 70 1.266 1.283 £978.00 £1,217.00 £2,195.00 £1,079.00 £1,334.00 £2,413.00 Notes: i) Minimum ambient operating temperatures: RZQSG Cooling Heating -15°C -15°C Price List Update: Valid from 1st January 2017 33 SPLIT, SKY AIR HEAT PUMPS FFQ-C / RXS-L 600x600 Fully Flat Cassette Indoor Units Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Seasonal Efficiency (EN14825) Pdesign COOLING SEER Annual Energy Consumption Energy Label Seasonal Efficiency (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate (Cooling) High / Nom / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High mm kg White Silver FFQ25C FFQ35C FFQ50C FFQ60C 2.44 1.81 2.50 3.20 A++ 2.50 6.11 143 A+ 2.31 4.24 763 4.53 / 3.90 A/A 276 0.150 / 0.133 / 0.108 260 (306) 575 (620) 575 (620) 16 (18.8) 31 / 28.5 / 25 48 3.32 2.28 3.40 4.00 A++ 3.40 6.32 188 A+ 3.10 4.10 1059 3.78 / 3.50 A/B 460 0.167 / 0.142 / 0.108 260 (306) 575 (620) 575 (620) 16 (18.8) 34 / 30.5 / 25 51 4.62 3.40 4.70 5.50 A+ 5.00 5.93 295 A 3.84 3.90 1378 3.21 / 3.49 A/B 780 0.200 / 0.167 / 0.125 260 (306) 575 (620) 575 (620) 17.5 (20.2) 39 / 34 / 27 56 5.72 4.20 5.80 7.00 A+ 5.70 5.71 349 A+ 3.96 4.04 1373 3.02 / 3.41 B/B 945 0.242 / 0.208 / 0.158 260 (306) 575 (620) 575 (620) 17.5 (20.2) 43 / 40 / 32 60 RXS25L3 RXS35L3 RXS50L RXS60L 550 x 765 x 285 34 550 x 765 x 285 34 735 x 825 x 300 47 735 x 825 x 300 48 4.00 3.3 10 4.00 4.3 10 6.90 6.8 20 8.30 10.2 20 1ph A A A inches (mm) m m m g/m kg dBA dBA m3/sec ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price 3+E / 1.5 1/4 (6.4) / 3/8 (9.5) 3+E / 1.5 1/4 (6.4) / 1/2 (12.7) 20 15 10 20 15 10 1.0 46 / 43 61 0.588 1.2 48 / 44 61 0.600 30 20 10 30 20 10 1.7 48 / 44 62 0.848 1.5 49 / 46 62 0.836 £797.00 £722.00 £1,519.00 £842.00 £770.00 £1,612.00 20 ● ● £662.00 £496.00 £1,158.00 £724.00 £575.00 £1,299.00 Accessories: Notes: Accessory Ref Description Trade Price BYFQ60CW BYFQ60CS BYFQ60B3 BRYQ60AW BRYQ60AS BRC7F530W BRC7F530S BRC7EB530W BDBHQ44C60 KRP4A53/UK.FB2 KRP1B57/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE K.CWB90-2 K.DT1 K.CGS K.CGM Fully Flat Cassette Decoration Panel - White Fully Flat Cassette Decoration Panel - Sliver Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks) [compatible with previous model FXZQ-M9] Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions Wireless remote controller for White Ceiling Decoration Panel Wireless remote controller for Silver Ceiling Decoration Panel Wireless remote for Fully Flat Cassette Old Style Decoration Panel Sealing member for decoration panel-FFQ, FXZQ Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Adaptor PCB for Interlock to fresh air fan Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £206.00 £206.00 £177.00 £103.00 £103.00 £158.00 £158.00 £158.00 £95.00 £96.00 £104.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £37.00 £56.00 £223.00 £308.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) Infrared remote Trade price will be reduced by £79.00 if ordered instead of BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYFQ60CW White fully flat decoration panel v) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C Features: > > > > > > > Installed into suspended ceiling grids without cutting surrounding tiles Home Leave setting maintains pre-set temperature during periods of extended absence Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling 3 fan speeds can be selected: high, medium and low Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications Re-use of existing R22 and R407C piping possible 34 Residential, Commercial and Industrial SPLIT, SKY AIR HEAT PUMPS FBQ-D & FDXS-F / RXS-L Built in DC Ducted & Slim Concealed Ceiling Unit Indoor Units DC Ducted FDBQ25B Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) External Static Pressure Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low kW kW kW kW High / Nom Height Width Depth Pa mm mm mm kg dBA dBA Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kWh kW kWh kWh m3/sec FBQ35D RXS35L3 Height x Width x Depth Interconnection Wiring Piping Connections Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) High / Silent Operation Sound Power Air Flow Rate (Cooling) High FBQ60D FDXS25F FDXS50F9 FDXS60F RXS50L RXS60L RXS25L3 RXS35L3 RXS50L RXS60L mm kg 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 34 47 48 34 34 47 48 1ph (refer to databook) 1ph A 4.6 7.2 9.2 3.90 4.90 7.10 9.20 A 4.3 6.8 10.2 3.3 4.3 6.8 10.2 A 10 20 20 10 10 20 20 3+E / 1.5 3+E / 1.5 3+E / 1.5 3+E / 1.5 Multi inches (mm) combinations 1/4 (6.4) / 1/4 (6.4) / 1/2 (12.7) 1/4 (6.4) / 3/8 (9.5) 1/4 (6.4) / 1/2 (12.7) 3/8 (9.5) only m 20 30 30 20 20 30 30 m 15 20 20 15 15 20 20 m 10 10 10 10 10 10 10 g/m 20 20 kg 1.2 1.7 1.5 1.0 1.2 1.7 1.5 dBA 48 / 44 48 / 44 49 / 46 46 / 43 48 / 44 48 / 44 49 / 46 dBA 61 61 62 59 61 61 62 m3/sec 0.600 0.848 0.836 0.558 0.600 0.484 0.836 ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price ● ● £536.00 £575.00 £1,111.00 £563.00 £722.00 £1,285.00 £624.00 £770.00 £1,394.00 £410.00 £496.00 £906.00 Accessories: £459.00 £575.00 £1,034.00 £497.00 £722.00 £1,219.00 £545.00 £770.00 £1,315.00 Notes: Accessory Ref Description Trade Price BRC4C65 BRC2E52C Wireless remote controller Wired Simplified remote controller Recessed simplified remote (see page 100 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Supply air plenum for FBQ35D / FBQ50D (2 x 200mm spigots) Supply air plenum for FBQ60D (2 x 200mm spigots) Supply air plenum for FBQ60D (3 x 200mm spigots) Supply air plenum for FDXS25/35F (2 x 150mm spigots) Supply air plenum for FDXS60F & FDXS50F (4 x 150mm spigots) Return air plenum for FBQ35D / FBQ50D (2 x 200mm spigots) Return air plenum for FBQ60D (2 x 200mm spigots) Return air plenum for FBQ60D (3 x 200mm spigots) Return air plenum for FDXS25/35F (2 x 150mm spigots) Return air plenum for FDXS60F & FDXS50F (4 x 150mm spigots) Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 £158.00 £83.00 £188.00 £96.00 £198.00 £245.00 £262.00 £193.00 £42.00 £93.00 £97.00 £75.00 £82.00 £87.00 £70.00 £88.00 £82.00 £89.00 £97.00 £79.00 £101.00 £37.00 £56.00 £223.00 £308.00 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.SF2 UK.SF3 UK.SF3A UK.SAF5 UK.SAF7 UK.RC2 UK.RC3 UK.RC3A UK.RAC5 UK.RAC7 K.CWB90-2 K.DT1 K.CGS K.CGM FDXS35F 3.32 4.89 5.57 2.35 3.32 4.81 5.86 2.93 3.55 4.09 1.81 2.26 3.08 3.97 3.40 5.00 5.70 2.40 3.40 5.00 6.00 4.00 5.50 7.00 3.20 4.00 5.80 7.00 A++ A++ A+ A+ A A+ A 3.40 5.00 5.70 2.40 3.40 5.00 6.00 6.17 6.21 5.86 5.63 5.21 5.72 5.51 Multi 193 282 340 149 228 306 381 combinations only A+ A+ A+ A+ A A A 2.90 4.40 4.60 2.60 2.90 4.00 4.60 4.07 4.06 4.01 4.24 3.88 3.93 3.80 998 1517 1606 858 1047 1425 1693 3.99 / 4.02 3.52 / 3.83 3.45 / 3.71 3.74 / 4.00 2.96 / 3.48 3.03 / 3.1 2.91 / 3.21 A/A B/A B/A A/A A/B B/D C/C 426 710 826 325 574 825 1030 0.108 / - / 0.250 / 0.208 / 0.250 / 0.208 / 0.300 / 0.250 / 0.145 / 0.145 / 0.145 / 0.145 / 0.200 / 0.200 / 0.267 / 0.000 / 0.175 0.175 0.208 0.122 0.122 0.167 0.225 0.087 150 / 30 30.0 30.0 40.0 40.0 230 245 200 652 700 1000 750 1150 502 800 620 17 28 35 21 30 35 / - / 28 35 / 32 / 29 35 / 32 / 29 30 / 28 / 25 35 / 33 / 27 35 / 33 / 27 38 / 36 / 30 38 / 36 / 30 55 60 60 55 53 53 55 56 Outdoor Units Dimensions Weight Electrical Details Slim Ducted FBQ50D i) FBQ & FDXS fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures: RXS Cooling Heating -10°C -15°C vi) The FBQ35D fan coil requires a separate 1ph power supply. Refer to install manual for details Features: > Fan speed: 5 fan speeds can be selected, high to super low > Connection to multi outdoor possible > Re-use of existing R22 and R407C piping possible Price List Update: Valid from 1st January 2017 35 SPLIT, SKY AIR HEAT PUMPS FBQ-D / RZQG-L Built in DC Ducted – Seasonal Smart Indoor Units Single Phase FBQ71D Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) External Static Pressure Dimensions UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low High / Nom Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW 3 Phase FBQ125D FBQ140D FBQ71D mm kg 990 x 940 x 320 69 kWh kW kWh kWh m3/sec A A A inches (mm) m m m g/m kg dBA dBA m3/sec 7.93 4 20 50 30 30 2.9 48 / 43 64 0.983 1430 x 940 x 320 95 1ph 9.97 12.87 4 4 32 32 3+E / 1.5 3/8 ( 9.5) / 5/8 (15.9) 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 / 45 51 / 45 66 67 1.166 1.166 95 ● Trade Fan Coil Price Trade Condensing Unit Price Total System Price £895.00 £1,239.00 £2,134.00 95 990 x 940 x 320 80 16.43 4 32 2.98 4 16 75 30 30 50 30 30 4.0 52 / 45 69 1.400 2.9 48 / 43 64 0.983 £1,282.00 £1,978.00 £3,260.00 £895.00 £1,277.00 £2,172.00 ● £935.00 £1,575.00 £2,510.00 £1,106.00 £1,733.00 £2,839.00 1430 x 940 x 320 101 3ph 3.75 4.84 4 4 20 20 3+E / 1.5 3/8 ( 9.5) / 5/8 (15.9) 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 / 45 51 / 45 66 67 1.166 1.166 ● Accessories: 6.18 4 20 75 30 30 4.0 52 / 45 69 1.400 ● £935.00 £1,648.00 £2,583.00 £1,106.00 £1,813.00 £2,919.00 £1,282.00 £2,083.00 £3,365.00 Notes: Accessory Ref Description Trade Price BRC4C65 BRC2E52C Wireless remote controller Wired Simplified remote controller (without auto swing) Recessed simplified remote (see page 100 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. Energy control PCB for Sky Air and VRV. KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Supply air plenum for FBQ71D (2 x 200 spigots) Supply air plenum for FBQ71D (3 x 200mm spigots) Supply air plenum for FBQ100 - 125D (4 x 200mm spigots) Return air plenum for FBQ71D (2 x 200mm spigots) Return air plenum for FBQ71D (3 x 200mm spigots) Return air plenum for FBQ100 - 125D (4 x 200mm spigots) Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £158.00 £83.00 £188.00 £96.00 £236.00 £198.00 £262.00 £193.00 £42.00 £93.00 £97.00 £82.00 £87.00 £108.00 £89.00 £97.00 £121.00 £37.00 £47.00 £61.00 £308.00 £369.00 i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures: RZQG RZQSG Features: New chassis with height of 245mm makes the FBQ-D one of the slimmest medium static ducted units on the market Increased external static pressure up to 150 Pa Flexibility to set the required fan curve manually or to automatically select the correct fan curve, assuring comfort at all times Top efficiency, highest Energy label ranking in the market 36 FBQ140D Pa mm mm mm kg dBA dBA kW ECA Eligible > > > > FBQ125D RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.SF3 UK.SF3A UK.SF4 UK.RC3 UK.RC3A UK.RC4 K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL FBQ100D 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50 A++ A+ A++ A++ A+ A++ 6.80 9.50 12.00 6.80 9.50 12.00 6.16 5.87 6.11 6.16 5.87 6.11 386 566 687 386 566 687 A+ A++ A+ A+ A++ A+ 6.00 11.30 12.70 6.00 11.30 12.71 4.31 4.78 4.28 4.31 4.78 4.28 1949 3310 4154 1949 3310 4154 3.60 / 4.01 3.81 / 4.41 3.31 / 3.90 3.35 / 3.60 3.60 / 4.01 3.81 / 4.41 3.31 / 3.90 3.35 / 3.60 A/A A/A A/A A/B A/A A/A A/A A/B 944 1217 1813 2000 944 1217 1813 2000 0.300 / 0.250 / 0.483 / 0.433 / 0.567 / 0.483 / 0.567 / 0.483 / 0.300 / 0.250 / 0.483 / 0.433 / 0.567 / 0.483 / 0.567 / 0.483 / 0.208 0.383 0.392 0.393 0.208 0.383 0.392 0.393 150 / 30 150 / 40 150 / 50 150 / 30 150 / 40 150 / 50 245 245 1000 1400 1000 1400 800 800 35 46 35 46 30 / 28 / 25 34 / 32 / 30 37 / 35 / 32 30 / 28 / 25 34 / 32 / 30 37 / 35 / 32 56 58 62 62 56 58 62 62 Outdoor Units Dimensions Weight Electrical Details FBQ100D Residential, Commercial and Industrial Cooling Heating -15°C -15°C -20°C -15°C SPLIT, SKY AIR HEAT PUMPS FBQ-D / RZQSG-L Built in DC Ducted – Seasonal Classic Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate (Cooling) External Static Pressure Dimensions Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom / Low High / Nom Height Width Depth Weight Sound Pressure (Cooling) High / Nom / Low Sound Power kW kW kW kW kW kWh kW kWh kWh m3/sec Pa mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details FBQ71D FBQ100D 7.28 4.99 6.80 7.50 A+ 6.80 5.84 408 A+ 6.00 4.01 2095 3.43 / 3.92 A/A 991 0.300 / 0.250 / 0.208 150 / 30 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 7.60 4.15 2564 3.35 / 3.67 A/A 1418 0.483 / 0.433 / 0.383 150 / 40 3 Phase FBQ125D FBQ140D 13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A 12.00 5.47 768 A+ 7.60 4.01 2653 3.23 / 3.63 3.06 / 3.40 A/A B/B 1858 2190 0.567 / 0.483 / 0.567 / 0.483 / 0.392 0.393 150 / 50 FBQ100D 10.80 7.44 9.50 10.80 A+ 9.50 5.61 593.00 A+ 7.60 4.15 2564 3.35 / 3.67 A/A 1418 0.483 / 0.433 / 0.383 150 / 40 245 1000 1400 800 35 30 / 28 / 25 56 46 34 / 32 / 30 58 37 / 35 / 32 62 62 34 / 32 / 30 58 FBQ125D FBQ140D 13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A 12.00 5.47 768.00 A+ 7.60 4.01 2653 3.23 / 3.63 3.06 / 3.40 A/A B/B 1858 2190 0.567 / 0.483 / 0.567 / 0.483 / 0.392 0.393 150 / 50 245 1400 800 46 37 / 35 / 32 62 RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High Trade Fan Coil Price Trade Condensing Unit Price Total System Price mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec 770 x 900 x 320 72 8.46 4 20 50 15 30 2.75 49 / 49 65 0.866 £895.00 £853.00 £1,748.00 990 x 940 x 320 75 1ph 11.73 15.29 4 4 32 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 / 49 54 / 49 70 70 1.266 1.283 £935.00 £1,181.00 £2,116.00 £1,106.00 £1,295.00 £2,401.00 1430 x 940 x 320 95 18.15 4 32 50 30 30 4.0 53 / 49 69 1.383 £1,282.00 £1,442.00 £2,724.00 990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.39 5.72 6.79 4 4 4 20 20 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 / 49 54 / 49 53 / 49 70 70 69 1.266 1.283 1.383 £935.00 £1,217.00 £2,152.00 £1,106.00 £1,334.00 £2,440.00 £1,282.00 £1,486.00 £2,768.00 Price List Update: Valid from 1st January 2017 37 SPLIT, SKY AIR HEAT PUMPS FDQ-C / RZQG / RZQSG / RZQ-C Concealed Ceiling Unit - Ultra High Static – Seasonal Smart, Classic & Super Inverter Indoor Units Capacity Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency Air Flow Rate External Static Pressure Dimensions Weight Sound Pressure Sound Power UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Nom High / Nominal Height Width Depth High / Low kW kW kW kW kW kWh kW kWh kWh m3/sec Pa mm mm mm kg dBA dBA Outdoor Units Dimensions Weight Electrical Details Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High mm kg A A A inches (mm) m m m g/m kg dBA dBA m3/sec Trade Fan Coil Price Trade Condensing Unit Price Total System Price Single Phase 3 Phase Single Phase 3 Phase FDQ125C FDQ125C FDQ125C FDQ125C FDQ200B FDQ250B 13.60 9.30 12.00 13.50 A+ 12.00 5.81 723 A+ 12.71 4.21 4227 3.75 / 3.83 A/A 1600 0.650 / 0.467 200 / 50 300 1400 700 45 40 / 33 66 13.60 9.30 12.00 13.50 A+ 12.00 5.81 723 A+ 12.71 4.21 4227 3.75 / 3.83 A/A 1600 0.650 / 0.467 200 / 50 300 1400 700 45 40 / 33 66 13.60 9.30 12.00 13.50 A 12.00 5.20 807 A 7.60 3.90 2729 3.21 / 3.51 A/B 1870 0.650 / 0.467 200 / 50 300 1400 700 45 40 / 33 66 13.60 9.30 12.00 13.50 A 12.00 5.20 807 A 7.60 3.90 2729 3.21 / 3.51 A/B 1600 0.650 / 0.467 200 / 50 300 1400 700 45 40 / 33 66 19.40 16.30 20.00 23.00 3.21 / 3.41 A/B 3115 1.150 / 1.150 250 / 250 450 1400 900 89 45 / 45 81 23.50 20.70 25.00 27.00 2.81 / 3.21 C/C 4290 1.483 / 1.483 250 / 250 450 1400 900 94 47 / 47 82 RZQG125L9V1 RZQG125L8Y1 RZQSG125L9V1 RZQSG125L8Y1 RZQ200C RZQ250C 1430 x 940 x 320 95 1ph - see notes 14.80 4 32 1430 x 940 x 320 990 x 940 x 320 101 75 3ph - see notes 1ph - see notes 4.89 17.30 4 4 20 32 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 75 50 30 30 30 30 Refer to Installation Manual 4.0 2.9 51 / 45 54 / 49 67 70 1.166 1.283 75 30 30 4.0 51 / 45 67 1.166 £1,210.00 £1,733.00 £2,943.00 £1,210.00 £1,813.00 £3,023.00 £1,210.00 £1,295.00 £2,505.00 990 x 940 x 320 82 3ph - see notes 5.72 4 20 50 30 30 2.9 54 / 49 70 1.283 1680 x 930 x 765 1680 x 930 x 765 183 184 3ph - see notes 4.61 6.35 4 4 25 25 3+E / 1.5 3/8 (9.5) / 7/8 (22.2) 1/2 (12.7) / 7/8 (22.2) 100 100 30 30 30 30 Refer to Installation Manual 8.3 9.3 57 / 57 / 78 78 2.850 2.850 £1,210.00 £1,334.00 £2,544.00 Accessories: £1,545.00 £2,417.00 £3,962.00 £1,910.00 £2,610.00 £4,520.00 Notes: Accessory Ref Description Trade Price BRC4C65 EKRORO3 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KRCS01-1 KLIC-DI DTA112B51 K.CWB90-2 K.CWB140-2 K.DT2 K.CGL Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV Remote room mounted temperature sensor KNX Interface for Sky Air and VRV systems Adaptor PCB for interface to Daikin centralised control systems Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 100-140 including RXYSQ £158.00 £30.00 £96.00 £198.00 £245.00 £262.00 £48.00 £193.00 £93.00 £37.00 £47.00 £61.00 £369.00 Features: > High static units for longer ducted runs > Up to 250Pa External Static Pressure > Auto balancing air flow / ESP on commissioning > Comms, computer and server room cooling possible (Seasonal Smart only) > Super inverter technology: reduces power consumption by up to 70% compared to non inverter units > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart only) 38 Super Inverter (3 phase) Residential, Commercial and Industrial i) All fan coils supplied as standard with BRC1E53A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £79.00 if ordered in place of the BRC1E53A iii) Replacement technology not applicable to RZQ200 and RZQ250 iv) All fan coil units standard with auto restart after power failure v) All fan coils supplied as standard with air filter vi) Minimum ambient operating temperatures: RZQG RZQSG RZQ Cooling -15°C -15°C -5°C Heating -20°C -15°C -15°C vii) FDQ Fan Coil unit requires a separate 15 amp power supply Indoor Model Smart Single Phase Hi-COP Cassette Smart Three Phase Smart Single Phase Smart Three Phase Classic Single Phase Roundflow Classic Three Phase Inverter Single Phase Inverter Three Phase RXS Smart Single Phase Smart Three Phase Under Ceiling Cassette (FUQ) Classic Single Phase Classic Three Phase Fully Flat Cassette (FFQ) RXS Smart Single Phase Smart Three Phase Ducted Classic Single Phase Classic Three Phase RXS Slim Ducted High Static Ducted RXS Smart Single Phase Smart Three Phase Classic Single Phase Classic Three Phase RZQ-C Capacity Order Code Product Codes Included List Price 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 10.0kW 12.5kW 14.0kW 3.5kW 5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 7.1kW 10.0kW 12.5kW 7.1kW 10.0kW 12.5kW 10.0kW 12.5kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 7.1kW 10.0kW 12.5kW 14.0kW 10.0kW 12.5kW 14.0kW 3.5kW 5.0kW 6.0kW 2.5kW 3.5kW 5.0kW 6.0kW 12.5kW 12.5kW 12.5kW 12.5kW 20kW 25kW SB.FCQHG71F_FP/GLY SB.FCQHG100F_FP/GLY SB.FCQHG125F_FP/GLY SB.FCQHG140F_FP/GLY SB.FCQHG71F_FP/GLY SB.FCQHG100F_FP/GLY SB.FCQHG125F_FP/GLY SB.FCQHG140F_FP/GLY SB.FCQG71F_FP/GLV SB.FCQG100F_FP/GLV SB.FCQG125F_FP/GLV SB.FCQG140F_FP/GLV SB.FCQG71F_FP/GLY SB.FCQG100F_FP/GLY SB.FCQG125F_FP/GLY SB.FCQG140F_FP/GLY SB.FCQG71F_FP/SLV SB.FCQG100F_FP/SLV SB.FCQG125F_FP/SLV SB.FCQG140F_FP/SLV SB.FCQG100F_FP/SLY SB.FCQG125F_FP/SLY SB.FCQG140F_FP/SLY SB.FCQG71F_FP/AZQSV SB.FCQG100F_FP/AZQSV SB.FCQG125F_FP/AZQSV SB.FCQG140F_FP/AZQSV SB.FCQG100F_FP/AZQSY SB.FCQG125F_FP/AZQSY SB.FCQG140F_FP/AZQSY SB.FCQG35F_FP/RXSL3 SB.FCQG50F_FP/RXSL SB.FCQG60F_FP/RXSL SB.FUQ71C_F/GLV SB.FUQ100C_F/GLV SB.FUQ125C_F/GLV SB.FUQ71C_F/GLY SB.FUQ100C_F/GLY SB.FUQ125C_F/GLY SB.FUQ71C_F/SLV SB.FUQ100C_F/SLV SB.FUQ125C_F/SLV SB.FUQ100C_F/SLY SB.FUQ125C_F/SLY SB.FFQ25C_F/RXSL3 SB.FFQ35C_F/RXSL3 SB.FFQ5OC_F/RXSL SB.FFQ60C_F/RXSL SB.FBQ71D_F/GLV SB.FBQ100D_F/GLV SB.FBQ125D_F/GLV SB.FBQ140D_F/GLV SB.FBQ71D_F/GLY SB.FBQ100D_F/GLY SB.FBQ125D_F/GLY SB.FBQ140D_F/GLY SB.FBQ71D_F/SLV SB.FBQ100D_F/SLV SB.FBQ125D_F/SLV SB.FBQ140D_F/SLV SB.FBQ100D_F/SLY SB.FBQ125D_F/SLY SB.FBQ140D_F/SLY SB.FBQ35D_F/RXSL3 SB.FBQ5OD_F/RXSL SB.FBQ60D_F/RXSL SB.FDXS25F_F/RXSL3 SB.FDXS35F_F/RXSL3 SB.FDXS5OF9_F/RXSL SB.FDXS60F_F/RXSL SB.FDQ125C_F/GLV SB.FDQ125C_F/GLY SB.FDQ125C_F/SLV SB.FDQ125C_F/SLY SB.FDQ200B_F/RZQ SB.FDQ250B_F/RZQ BRC1E53A + BYCQ140D + FCQHG71F + RZQG71L9V1 BRC1E53A + BYCQ140D + FCQHG100F + RZQG100L9V1 BRC1E53A + BYCQ140D + FCQHG125F + RZQG125L9V1 BRC1E53A + BYCQ140D + FCQHG140F + RZQG140L9V1 BRC1E53A + BYCQ140D + FCQHG71F + RZQG71L8Y1 BRC1E53A + BYCQ140D + FCQHG100F + RZQG100L8Y1 BRC1E53A + BYCQ140D + FCQHG125F + RZQG125L8Y1 BRC1E53A + BYCQ140D + FCQHG140F + RZQG140LY1 BRC1E53A + BYCQ140D + FCQG71F + RZQG71L9V1 BRC1E53A + BYCQ140D + FCQG100F + RZQG100L9V1 BRC1E53A + BYCQ140D + FCQG125F + RZQG125L9V1 BRC1E53A + BYCQ140D + FCQG140F + RZQG140L9V1 BRC1E53A + BYCQ140D + FCQG71F + RZQG71L8Y1 BRC1E53A + BYCQ140D + FCQG100F + RZQG100L8Y1 BRC1E53A + BYCQ140D + FCQG125F + RZQG125L8Y1 BRC1E53A + BYCQ140D + FCQG140F + RZQG140LY1 BRC1E53A + BYCQ140D + FCQG71F + RZQSG71L3V1 BRC1E53A + BYCQ140D + FCQG100F + RZQSG100L9V1 BRC1E53A + BYCQ140D + FCQG125F + RZQSG125L9V1 BRC1E53A + BYCQ140D + FCQG140F + RZQSG140L9V1 BRC1E53A + BYCQ140D + FCQG100F + RZQSG100L8Y1 BRC1E53A + BYCQ140D + FCQG125F + RZQSG125L8Y1 BRC1E53A + BYCQ140D + FCQG140F + RZQSG140LY1 BRC1E53A + BYCQ140D + FCQG71F + AZQS71BV1 BRC1E53A + BYCQ140D + FCQG100F + AZQS100B8V1 BRC1E53A + BYCQ140D + FCQG125F + AZQS125B8V1 BRC1E53A + BYCQ140D + FCQG140F + AZQS140B8V1 BRC1E53A + BYCQ140D + FCQG100F + AZQS100BY1 BRC1E53A + BYCQ140D + FCQG125F + AZQS125BY1 BRC1E53A + BYCQ140D + FCQG140F + AZQS140BY1 BRC1E53A + BYCQ140D + FCQG35F + RXS35L3 BRC1E53A + BYCQ140D + FCQG50F + RXS50L BRC1E53A + BYCQ140D + FCQG60F + RXS60L BRC1E53A + FUQ71C + RZQG71L9V1 BRC1E53A + FUQ100C + RZQG100L9V1 BRC1E53A + FUQ125C + RZQG125L9V1 BRC1E53A + FUQ71C + RZQG71L8Y1 BRC1E53A + FUQ100C + RZQG100L8Y1 BRC1E53A + FUQ125C + RZQG125L8Y1 BRC1E53A + FUQ71C + RZQSG71L3V1 BRC1E53A + FUQ100C + RZQSG100L9V1 BRC1E53A + FUQ125C + RZQSG125L9V1 BRC1E53A + FUQ100C + RZQSG100L8Y1 BRC1E53A + FUQ125C + RZQSG125L8Y1 BRC1E53A + BYFQ60CW + FFQ25C + RXS35L3 BRC1E53A + BYFQ60CW + FFQ35C + RXS35L3 BRC1E53A + BYFQ60CW + FFQ50C + RXS50L BRC1E53A + BYFQ60CW + FFQ60C + RXS60L BRC1E53A + FBQ71D + RZQG71L9V1 BRC1E53A + FBQ100D + RZQG100L9V1 BRC1E53A + FBQ125D + RZQG125L9V1 BRC1E53A + FBQ140D + RZQG140L9V1 BRC1E53A + FBQ71D + RZQG71L8Y1 BRC1E53A + FBQ100D + RZQG100L8Y1 BRC1E53A + FBQ125D + RZQG125L8Y1 BRC1E53A + FBQ140D + RZQG140LY1 BRC1E53A + FBQ71D + RZQSG71L3V1 BRC1E53A + FBQ100D + RZQSG100L9V1 BRC1E53A + FBQ125D + RZQSG125L9V1 BRC1E53A + FBQ125D + RZQSG125L9V1 BRC1E53A + FBQ100D + RZQSG100L8Y1 BRC1E53A + FBQ125D + RZQSG125L8Y1 BRC1E53A + FBQ140D + RZQSG140LY1 BRC1E53A + FBQ35D + RXS35L3 BRC1E53A + FBQ50D + RXS50L BRC1E53A + FBQ60D + RXS60L BRC1E53A + FDXS25F + RXS35L3 BRC1E53A + FDXS35F + RXS35L3 BRC1E53A + FDXS50F9 + RXS50L BRC1E53A + FDXS60F + RXS60L BRC1E53A + FDQ125C + RZQG125L9V1 BRC1E53A + FDQ125C + RZQG125L8Y1 BRC1E53A + FDQ125C + RZQSG125L9V1 BRC1E53A + FDQ125C + RZQSG125L8Y1 BRC1E53A + FDQ200B + RZQ200C BRC1E53A + FDQ250D + RZQ250C £2,058.00 £2,501.00 £2,745.00 £3,193.00 £2,058.00 £2,501.00 £2,745.00 £3,193.00 £2,058.00 £2,501.00 £2,745.00 £3,193.00 £2,096.00 £2,574.00 £2,825.00 £3,298.00 £1,672.00 £2,107.00 £2,307.00 £2,657.00 £2,143.00 £2,346.00 £2,701.00 £1,562.00 £1,840.00 £2,038.00 £2,364.00 £1,890.00 £2,092.00 £2,426.00 £1,286.00 £1,450.00 £1,543.00 £2,131.00 £2,553.00 £2,812.00 £2,169.00 £2,626.00 £2,892.00 £1,745.00 £2,159.00 £2,374.00 £2,195.00 £2,413.00 £1,237.00 £1,299.00 £1,519.00 £1,612.00 £2,134.00 £2,510.00 £2,839.00 £3,260.00 £2,172.00 £2,583.00 £2,919.00 £3,365.00 £1,748.00 £2,116.00 £2,401.00 £2,401.00 £2,152.00 £2,440.00 £2,768.00 £1,111.00 £1,285.00 £1,394.00 £985.00 £1,034.00 £1,219.00 £1,315.00 £2,943.00 £3,023.00 £2,505.00 £2,544.00 £4,041.00 £4,599.00 Price List Update: Valid from 1st January 2017 39 SPLIT, SKY AIR HEAT PUMPS To simplify the order process, you may want to use the Order Code from table below. Each code includes all products for a system (eg remote controllers, indoor units) & means you no longer need to order individual materials. SPLIT, SKY AIR HEAT PUMPS I W I- F O L TR CO N A P P V IA Multi Series Multi Series Inverters offer the ability to connect up to five fan coils to one outdoor unit. With the MXS range it is possible to install indoor units throughout a house or small commercial premises and only use one outdoor unit. Each indoor unit will have its own controller and will be able to operate in heating or cooling. Heating & cooling Connectable Indoor Units Wall mounted FTXG-L CTXS-K Floor standing FTXS-K FTXS-G FTX-KV FVXG-K FVXS-F Flexi type Roundflow cassette Fully flat cassette FLXS-B(9) FCQG-F FFQ-C Concealed ceiling FDXS-F(9) Ceiling Concealed suspended floor standing FDBQ-B/FBQ-D FHQ-C FNQ-A 20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60 25 35 50 60 2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units. The online tool has four simple steps: > select number of rooms > select capacity per room > select capacity of outdoor > select type of indoor & input pipe run & level difference It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor unit and generates a report showing full energy label for specific combination and pictures of all equipment selected. This can be used by installers to select Multi systems, and also to show end-users the configuration of the system. Go to www.daikineurope.com/multiselection Multi Split & Mini VRV Fan Coils Emura Wall Mounted Fan Coil Units Trade Fan Coil Unit Price FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS £273.00 £288.00 £323.00 £426.00 £326.00 £343.00 £384.00 £508.00 Wall Mounted Standard Inverter Fan Coil Units Trade Fan Coil Unit Price CTXS15K £152.00 FTXS20K £160.00 FTXS25K £172.00 Wall Mounted Low Inverter Fan Coil Units Trade Fan Coil Unit Price FTX20KV £112.00 FTX25KV £124.00 FTX35KV £141.00 Flexi Fan Coil Units Trade Fan Coil Unit Price FLXS25B £392.00 FLXS35B9 £440.00 FLXS50B £478.00 Nexura Floor Standing Fan Coil Units Trade Fan Coil Unit Price FVXG25K £657.00 FVXG35K £707.00 FVXG50K £774.00 Floor Standing Cased Fan Coil Units Trade Fan Coil Unit Price FVXS25F £544.00 FVXS35F £587.00 FVXS50F £641.00 Compact Roundflow Cassette Fan Coil Units Trade Fan Coil Unit Price FCQG35F £711.00 FCQG50F £728.00 FCQG60F £773.00 600 x 600 Fully Flat Cassette Fan Coil Units Trade Fan Coil Unit Price FFQ25C £662.00 FFQ35C £724.00 FFQ50C £797.00 Ceiling Suspended Fan Coil Units Trade Fan Coil Unit Price FHQ35CB £693.00 FHQ50CB £751.00 FHQ60CB £824.00 Concealed Ceiling Fan Coil Units Trade Fan Coil Unit Price FDBQ25B £441.00 FBQ35D £536.00 FBQ50D £563.00 FBQ60D £624.00 Slim Concealed Ceiling Fan Coil Units Trade Fan Coil Unit Price FDXS25F £410.00 FDXS35F £459.00 FDXS50F9 £497.00 FDXS60F £545.00 Concealed Floor Standing Unit Trade Fan Coil Unit Price FNQ25A £424.00 FNQ35A £524.00 FNQ50A £610.00 FNQ60A £672.00 40 Residential, Commercial and Industrial FTXS35K £197.00 FTXS42K £221.00 FTXS50K £306.00 FTXS60G £312.00 FTXS71G £416.00 FLXS60B £526.00 Notes: FFQ60C £842.00 i) Accessories for fan coils - refer to pair system pages ii) All fan coil units standard with auto restart after power failure iii) All fan coil units supplied as standard with remote controller iv) FDXS fan coil units supplied as standard with air filter v) 2MXS40-50H can only be used with FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS, FNQ, FFQ-C fan coil units vi) One wifi adaptor per fan coil for online control SPLIT, SKY AIR HEAT PUMPS MXS-E/F/G/H/K Multi Series Inverters Outdoor Units Capacity Dimensions Weight Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating Height Width Depth Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Nom Maximum Length Maximum Vertical Rise Liquid Gas Number of Connected Indoor Units Air Flow Rate (Cooling) Nom Trade Condensing Unit Price kW kW mm mm mm kg Phase Hz V amps amps amps kg dBA m m inches (mm) inches (mm) m3/sec 2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E 4.00 4.40 550 765 285 38 5.00 5.70 550 765 285 42 4.00 4.60 735 936 300 49 5.20 6.80 735 936 300 49 6.80 8.60 735 936 300 58 6.80 8.60 735 936 300 58 8.00 9.60 770 900 320 72 9.00 10.40 770 900 320 73 4 20 4 20 4 20 2.6 48 61 60 15 4x 1/4 (6.4) 2x 3/8 (9.5) 2x 1/2 (12.7) 3.0 52 66 75 15 5x 1/4 (6.4) 2x3/8 (9.5) 1/2 (12.7) 2x 5/8 (15.9) 5 0.908 £2,227.00 1ph 50 230 Refer to Multi Combination Tables 4 4 20 20 R410A 2.0 2.6 46 48 59 61 50 60 15 15 3x 1/4 (6.4) 3x 1/4 (6.4) 2x 3/8 (9.5) 3/8 (9.5) 1/2 (12.7) 2x 1/2 (12.7) 4 16 4 16 4 16 1.2 47 62 30 15 2x 1/4 (6.4) 2x 3/8 (9.5) 1.6 48 63 30 15 2x 1/4 (6.4) 3/8 (9.5) 1/2 (12.7) 2.0 46 59 50 15 3x 1/4 (6.4) 2x 3/8 (9.5) 1/2 (12.7) 2 0.55 2 0.567 3 0.75 3 0.75 3 0.823 4 0.823 3.0 48 62 70 15 4x 1/4 (6.4) 3/8 (9.5) 1/2 (12.7) 2x 5/8 (15.9) 4 0.908 £1,038.00 £1,149.00 £1,082.00 £1,203.00 £1,703.00 £1,837.00 £2,069.00 Accessories: Notes: Accessory Ref Description Trade Price K.CWB90-2 K.DT1 K.DT2 K.CGM Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 £37.00 £56.00 £61.00 £308.00 i) Minimum ambient operating temperatures: 2MXS40, 50 3MXS40, 52, 68 4MXS68, 80 5MXS90 Cooling Heating 10°C -10°C -10°C -10°C -15°C -15°C -15°C -15°C Painted Units Customers sometimes require visible units to be less obtrusive, whether for aesthetic or planning reasons. Daikin UK offer a customised service where we can repaint our units to any specified RAL or BS finish. Our repainting service is done in house in our purpose built facility and includes removing base paint to give a uniform, long lasting and professional finish. We have repainted fan coils, decoration panels, BS boxes and all types of condensers for a number of clients. PRICE ON APPLICATION Lead time: 2-3 weeks Applicable units: All When asking for a quotation or ordering, please state the unit you require along with the finish requirements e.g. colour, pattern etc. Please note: The stated lead times are a guide, this can be influenced by the design and complexity of the requirement. Price List Update: Valid from 1st January 2017 41 VRV IV Condensing Unit – Low Height Compact Mini VRV Outdoor Units Capacity Power Input 50Hz Nominal Cooling Nominal Heating Cooling Heating EER COP Dimensions Height x Width x Depth Weight Refrigerant Circuit Refrigerant Type Sound Pressure (Nom) Cooling Sound Power (Nom) Cooling Maximum No of Connectable Units Electrical Details Power Supply Running Current Starting Current Fuse Rating Piping Limits Total Piping length Maximum Length Maximum Vertical Rise Piping Connections Liquid Gas Capacity Index Limit RXYSCQ4TV1 RXYSCQ5TV1 12.1 12.1 3.43 3.18 3.53 3.81 14.0 14.0 4.26 3.91 3.29 3.58 kW kW kW kW mm kg 823 x 940 x 460 94 94 R410A dBA dBA 51 68 8 Phase / Hz / V amps amps amps m m m inch (mm) inch (mm) Trade Condensing Unit Price 52 69 10 1 / 50 / 230 19.0 4 32 300 70 (90 equivalent) 30 3/8 (9.5) 5/8 (15.9) 50~130 3/8 (9.5) 5/8 (15.9) 62.5~162.5 £2,561.00 £2,878.00 823mm high > New low height Mini VRV, making complying with planning restrictions in towns and cities easier > Compact – Only 823mm high > Lightweight – for simple installation > Variable Refrigerant temperature – Enhanced efficiency > In addition to VRV fan coils, low height Mini VRV is connectable to: Stylish indoor units – Emura and Nexura – as well as Air Handling Units and Biddle Air curtains > Single phase Less than 1m Features: Parapet wall SPLIT, SKY AIR HEAT PUMPS VRV IV S-Series RXYSCQ-T Roof BPMK Mini VRV for Residential Applications > Multi Series Inverters can connect up to five indoor units from across the split range > Up to nine indoor units can be connected to a single Mini-VRV outdoor unit. To allow connection of the split indoor units, the system will need two or three port BPMK boxes > BPMK boxes open up the full range of split indoor unit style – from the stylish Emura to the radiant heat of the Nexura > For full details of the expanded range of capacities in the Mini-VRV range, including the new low height S series, refer to page 70 Daikin’s range of split indoor units Dimensions Weight Total Indoor Capacity Connectable Units Electrical Details Height x Width x Depth Piping Limits Piping Connections Indoor Piping Connections Outdoor BPMKS967A2 mm kg kW Power Supply Power Input kW Maximum Total - outdoor to BPMK box Distance from BPMK to indoor Liquid Inches (mm) Gas Inches (mm) Liquid Inches (mm) Gas Inches (mm) Trade List Price BPMKS967A3 180 x 650 x 350 7.5 14.2 2 8.0 20.8 3 1~ 220 - 240V, 50 Hz 0.01 55 15 2 x 1/4 (6.4) 2 x 5/8 (15.9) 1 x 3/8 (9.5) 1 / 3/4 (19.0) 0.01 55 15 3 x 1/4 (6.4) 3 x 5/8 (15.9) 1 x 3/8 (9.5) 1 / 3/4 (19.0) £371.00 £396.00 Accessories: Notes: Accessory Ref Description Trade Price KHRQ22M20T R410A 2 Pipe refnet joint £30.00 42 Residential, Commercial and Industrial i) Mini-VRV units are subject to VRV discount level. Split indoor units bought to connect to mini VRV are still subject to Split discount levels. BPMK Boxes are bought at accessories discount levels. SPLIT, SKY AIR HEAT PUMPS RZQ-C Super Inverter Outdoor Units Capacity Super Inverter Nominal Cooling Nominal Heating EER COP Annual energy consumption Dimensions Height Width Depth Weight Electrical Details Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High / Nom* RZQ200C 20.0 23.0 3.21 3.41 3115 1680 930 765 183 kW kW kWh mm mm mm kg RZQ250C 24.1 26.4 2.81 3.21 4290 1680 930 765 184 3ph data book A A A 4 25 4 25 3+E / 1.5 inches (mm) m m m g/m kg dBA 3/8 (9.5) / 7/8 (22.2) 100 30 30 1/2 (12.7) / 7/8 (22.2) 100 30 30 Refer to Installation Manual m3/sec Trade Condensing Unit Price 8.3 57 / 78 2.85* 9.3 57 / 78 2.85* £2,417.00 £2,610.00 Possible Combinations Twin, Triple and Double Twin Outdoor Units Outdoor 20kW Twin RZQ200C Three Phase 20kW Triple RZQ200C Three Phase 20kW Triple RZQ200C Three Phase 20kW Double Twin RZQ200C Three Phase 25kW Twin RZQ250C Three Phase 25kW Double Twin RZQ250C Three Phase Indoor Type Material Remote Refnet System Price Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette Hi-COP Cassette Under Ceiling Cassette Ceiling Suspended Ducted Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing 2 x FCQG100F 2 x FCQHG100F 2 x FUQ100C 2 x FAQ100C9 2 x FHQ100C 2 x FBQ100D 3 x FCQG60F 3 x FFQ60C 3 x FHQ60C 3 x FBQ60D 3 x FDXS60F 3 x FNQ60A 3 x FCQG71F 3 x FCQHG71F 3 x FUQ71C 3 x FAQ71CB 3 x FHQ71C 3 x FBQ71D 4 x FCQG50F 4 x FFQ50C 4 x FHQ50C 4 x FBQ50D 4 x FDXS50F9 4 x FNQ50A 2 x FCQG125F 2 x FCQHG125F 2 x FUQ125C 2 x FHQ125C 2 x FBQ125D 4 x FCQG60F 4 x FFQ60C 4 x FHQ60C 4 x FBQ60D 4 x FDXS60F 4 x FNQ60A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 1 x KHRQ250H7 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T £4,220.00 £4,220.00 £4,324.00 £4,050.00 £4,414.00 £4,238.00 £4,662.00 £4,869.00 £4,815.00 £4,215.00 £3,978.00 £4,359.00 £4,800.00 £4,800.00 £5,019.00 £4,680.00 £5,232.00 £5,028.00 £5,182.00 £5,458.00 £5,274.00 £4,522.00 £4,258.00 £4,710.00 £4,585.00 £4,585.00 £4,719.00 £5,119.00 £4,773.00 £5,555.00 £5,831.00 £5,759.00 £4,959.00 £4,643.00 £5,151.00 Price List Update: Valid from 1st January 2017 43 SPLIT, SKY AIR HEAT PUMPS RZQG-L Seasonal Smart Outdoor Units Dimensions Height Width Depth Weight Electrical Details Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High / Nom* Seasonal Smart Seasonal Smart Single Phase 3 Phase RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 mm 990 1430 1430 1430 990 1430 1430 1430 mm 940 940 940 940 940 940 940 940 mm 320 320 320 320 320 320 320 320 kg 78 102 102 102 80 101 101 101 1ph 3ph A data book data book A 4 4 4 4 4 4 4 4 A 20 32 32 32 16 20 20 20 3+E / 1.5 inches (mm) 3/8 (9.5) / 5/8 (15.9) m 50 75 75 75 50 75 75 75 m 30 m 30 g/m Refer to Installation Manual kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 dBA 48 / 43 50 / 45 51 / 45 52 / 45 48 / 43 50 / 45 51 / 45 52 / 45 64 66 67 69 64 66 67 69 m3/sec 0.983 1.167 1.167 1.400 0.983 1.167 1.167 1.400 Trade Condensing Unit Price £1,239.00 £1,575.00 £1,733.00 £1,978.00 £1,277.00 £1,648.00 £1,813.00 £2,083.00 Possible Combinations Twin, Triple and Double Twin Outdoor Units Outdoor RZQG71L9V1 Single Phase 7.1kW Twin RZQG71L8Y1 Three Phase RZQG100L9V1 Single Phase 10kW Twin RZQG100L8Y1 Three Phase RZQG100L9V1 Single Phase 10kW Triple RZQG100L8Y1 Three Phase RZQG125L9V1 Single Phase 12kW Twin RZQG125L8Y1 Three Phase 44 Residential, Commercial and Industrial Indoor Type Material Remote Refnet System Price Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing 2 x FCQG35F 2 x FFQ35C 2 x FHQ35CB 2 x FBQ35D 2 x FDXS35F 2 x FNQ35A 2 x FCQG35F 2 x FFQ35C 2 x FHQ35CB 2 x FBQ35D 2 x FDXS35F 2 x FNQ35A 2 x FCQG50F 2 x FFQ50C 2 x FHQ50CB 2 x FBQ50D 2 x FDXS50F9 2 x FNQ50A 2 x FCQG50F 2 x FFQ50C 2 x FHQ50CB 2 x FBQ50D 2 x FDXS50F9 2 x FNQ50A 3 x FCQG35F 3 x FFQ35C 3 x FHQ35CB 3 x FBQ35D 3 x FDXS35F 3 x FNQ35A 3 x FCQG35F 3 x FFQ35C 3 x FHQ35CB 3 x FBQ35D 3 x FDXS35F 3 x FNQ35A 2 x FCQG60F 2 x FFQ60C 2 x FHQ60CB 2 x FBQ60D 2 x FDXS60F 2 x FNQ60A 2 x FCQG60F 2 x FFQ60C 2 x FHQ60CB 2 x FBQ60D 2 x FDXS60F 2 x FNQ60A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T £2,612.00 £2,638.00 £2,576.00 £2,262.00 £2,108.00 £2,238.00 £2,650.00 £2,676.00 £2,614.00 £2,300.00 £2,146.00 £2,276.00 £2,982.00 £3,120.00 £3,028.00 £2,652.00 £2,520.00 £2,746.00 £3,055.00 £3,193.00 £3,101.00 £2,725.00 £2,593.00 £2,819.00 £3,615.00 £3,654.00 £3,561.00 £3,090.00 £2,859.00 £3,054.00 £3,688.00 £3,727.00 £3,634.00 £3,163.00 £2,932.00 £3,127.00 £3,230.00 £3,368.00 £3,332.00 £2,932.00 £2,774.00 £3,028.00 £3,310.00 £3,448.00 £3,412.00 £3,012.00 £2,854.00 £3,108.00 RZQG125L9V1 Single Phase 12kW Triple RZQG125L8Y1 Three Phase RZQG125L9V1 Single Phase 12kW Double Twin RZQG125L8Y1 Three Phase RZQG140L9V1 Single Phase 14kW Twin RZQG140LY1 Three Phase RZQG140L9V1 Single Phase 14kW Triple RZQG140LY1 Three Phase RZQG140L9V1 Single Phase 14kW Double Twin RZQG140LY1 Three Phase Indoor Type Material Remote Refnet System Price Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F9 3 x FNQ50A 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F9 3 x FNQ50A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 2 x FCQG71F 2 x FCQHG71F 2 x FUQ71C 2 x FAQ71C9 2 x FHQ71CB 2 x FBQ71D 2 x FCQG71F 2 x FCQHG71F 2 x FUQ71C 2 x FAQ71C9 2 x FHQ71CB 2 x FBQ71D 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F9 3 x FNQ50A 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F 3 x FNQ50A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T £3,824.00 £4,031.00 £3,893.00 £3,329.00 £3,131.00 £3,470.00 £3,904.00 £4,111.00 £3,973.00 £3,409.00 £3,211.00 £3,550.00 £4,430.00 £4,482.00 £4,358.00 £3,730.00 £3,422.00 £3,682.00 £4,510.00 £4,562.00 £4,438.00 £3,810.00 £3,502.00 £3,762.00 £3,567.00 £3,567.00 £3,713.00 £3,487.00 £3,855.00 £3,719.00 £3,672.00 £3,672.00 £3,818.00 £3,592.00 £3,960.00 £3,824.00 £4,069.00 £4,276.00 £4,138.00 £3,574.00 £3,376.00 £3,715.00 £4,174.00 £4,381.00 £4,243.00 £3,679.00 £3,481.00 £3,820.00 £4,675.00 £4,727.00 £4,603.00 £3,975.00 £3,667.00 £3,927.00 £4,780.00 £4,832.00 £4,708.00 £4,080.00 £3,772.00 £4,032.00 SPLIT, SKY AIR HEAT PUMPS Outdoor Accessories: Accessory Ref Description Trade Price KHRQ22M20T KHRQ127H KHRQ250H7 K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL R410A 2 Pipe Refnet Joint Triple Refnet Joint - RZQS71~140,RZQ100~140 Triple Refnet Joint - RZQ200~250 Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £30.00 £65.00 £84.00 £37.00 £47.00 £61.00 £308.00 £369.00 Notes: i) Accessories for fan coils and condensing units - refer to pair system pages Maximum Fuse size for Twin, Triple and Double Twin Outdoor Units Outdoor Units Power 71 100 125 140 200 RZQG & RZQSG Single Phase 20 amp 32 amp 32 amp 32 amp - - Three Phase 16 amp 20 amp 20 amp 20 amp - - Three Phase - - - - 20amp 20amp RZQ-C 250 Note: Max fuse size based on current price list series indoor units. Refer to data-book for more details. Price List Update: Valid from 1st January 2017 45 SPLIT, SKY AIR HEAT PUMPS RZQSG-L Seasonal Classic Outdoor Units Dimensions Height Width Depth Weight Electrical Details Power Supply Running Current Starting Current Max Fuse Size Interconnection Wiring Core / Cable size Piping Connections Liquid / Gas Pipework Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge Sound Pressure (Cooling) Nom / Night Quiet Sound Power Air Flow Rate (Cooling) High mm mm mm kg A A A inches (mm) m m m g/m kg dBA m3/sec Trade Condensing Unit Price RZQSG71L3V1 770 900 320 67 4 20 50 2.75 49 / 49 65 0.870 £853.00 Seasonal Classic Seasonal Classic Single Phase 3 Phase RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 990 990 1430 990 990 940 940 940 940 940 320 320 320 320 320 81 81 102 82 82 1ph 3ph data book data book 4 4 4 4 4 32 32 32 20 20 3+E / 1.5 3/8 (9.5) / 5/8 (15.9) 50 50 50 50 50 30 30 Refer to Installation Manual 2.9 2.9 4.0 2.9 2.9 53 / 49 54 / 49 53 / 49 53 / 49 54 / 49 69 70 69 69 70 1.270 1.280 1.380 1.270 1.280 £1,181.00 £1,295.00 £1,442.00 £1,217.00 £1,334.00 RZQSG140LY1 1430 940 320 101 4 20 50 4.0 53 / 49 69 1.380 £1,486.00 Possible Combinations Twin, Triple and Double Twin Outdoor Units Outdoor 7.1kW Twin RZQSG71L3V1 Single Phase RZQSG100L9V1 Single Phase 10kW Twin RZQSG100L8Y1 Three Phase RZQSG100L9V1 Single Phase 10kW Triple RZQSG100L8Y1 Three Phase RZQSG125L9V1 Single Phase 12kW Twin RZQSG125L8Y1 Three Phase 46 Residential, Commercial and Industrial Indoor Type Material Remote Refnet System Price Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing 2 x FCQG35F 2 x FFQ35C 2 x FHQ35CB 2 x FBQ35D 2 x FDXS35F 2 x FNQ35A 2 x FCQG50F 2 x FFQ50C 2 x FHQ50CB 2 x FBQ50D 2 x FDXS50F9 2 x FNQ50A 2 x FCQG50F 2 x FFQ50C 2 x FHQ50CB 2 x FBQ50D 2 x FDXS50F9 2 x FNQ50A 3 x FCQG35F 3 x FFQ35C 3 x FHQ35CB 3 x FBQ35D 3 x FDXS35F 3 x FNQ35A 3 x FCQG35F 3 x FFQ35C 3 x FHQ35CB 3 x FBQ35D 3 x FDXS35F 3 x FNQ35A 2 x FCQG60F 2 x FFQ60C 2 x FHQ60CB 2 x FBQ60D 2 x FDXS60F 2 x FNQ60A 2 x FCQG60F 2 x FFQ60C 2 x FHQ60CB 2 x FBQ60D 2 x FDXS60F 2 x FNQ60A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T £2,226.00 £2,252.00 £2,190.00 £1,876.00 £1,722.00 £1,852.00 £2,588.00 £2,726.00 £2,634.00 £2,258.00 £2,126.00 £2,352.00 £2,624.00 £2,762.00 £2,670.00 £2,294.00 £2,162.00 £2,388.00 £3,221.00 £3,260.00 £3,167.00 £2,696.00 £2,465.00 £2,660.00 £3,257.00 £3,296.00 £3,203.00 £2,732.00 £2,501.00 £2,696.00 £2,792.00 £2,930.00 £2,894.00 £2,494.00 £2,336.00 £2,590.00 £2,831.00 £2,969.00 £2,933.00 £2,533.00 £2,375.00 £2,629.00 RZQSG125L9V1 Single Phase 12kW Triple RZQSG125L8Y1 Three Phase RZQSG125L9V1 Single Phase 12kW Double Twin RZQSG125L8Y1 Three Phase RZQSG140L9V1 Single Phase 14kW Twin RZQSG140LY1 Three Phase RZQSG140L9V1 Single Phase 14kW Triple RZQSG140LY1 Three Phase RZQSG140L9V1 Single Phase 14kW Double Twin RZQSG140LY1 Three Phase Indoor Type Material Remote Refnet System Price Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette Hi-COP Cassette Under Ceiling Cassette Wall Mount Ceiling Suspended Ducted Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing Cassette 600 x 600 Fully Flat Cassette Ceiling Suspended Ducted Slim Duct Concealed Floor Standing 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F9 3 x FNQ50A 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F 3 x FNQ50A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 2 x FCQG71F 2 x FCQHG71F 2 x FUQ71C 2 x FAQ71C9 2 x FHQ71CB 2 x FBQ71D 2 x FCQG71F 2 x FCQHG71F 2 x FUQ71C 2 x FAQ71C9 2 x FHQ71CB 2 x FBQ71D 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F9 3 x FNQ50A 3 x FCQG50F 3 x FFQ50C 3 x FHQ50CB 3 x FBQ50D 3 x FDXS50F 3 x FNQ50A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 4 x FCQG35F 4 x FFQ35C 4 x FHQ35CB 4 x FBQ35D 4 x FDXS35F 4 x FNQ35A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x BRC1E53A 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ22M20T 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 1 x KHRQ127H 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T 3 x KHRQ22M20T £3,386.00 £3,593.00 £3,455.00 £2,891.00 £2,693.00 £3,032.00 £3,425.00 £3,632.00 £3,494.00 £2,930.00 £2,732.00 £3,071.00 £3,992.00 £4,044.00 £3,920.00 £3,292.00 £2,984.00 £3,244.00 £4,031.00 £4,083.00 £3,959.00 £3,331.00 £3,023.00 £3,283.00 £3,031.00 £3,031.00 £3,177.00 £2,951.00 £3,319.00 £3,183.00 £3,075.00 £3,075.00 £3,221.00 £2,995.00 £3,363.00 £3,227.00 £3,533.00 £3,740.00 £3,602.00 £3,038.00 £2,840.00 £3,179.00 £3,577.00 £3,784.00 £3,646.00 £3,082.00 £2,884.00 £3,223.00 £4,139.00 £4,191.00 £4,067.00 £3,439.00 £3,131.00 £3,391.00 £4,183.00 £4,235.00 £4,111.00 £3,483.00 £3,175.00 £3,435.00 SPLIT, SKY AIR HEAT PUMPS Outdoor Accessories: Accessory Ref Description Trade Price KHRQ22M20T KHRQ127H KHRQ250H7 K.CWB90-2 K.CWB140-2 K.DT2 K.CGM K.CGL R410A 2 Pipe Refnet Joint Triple Refnet Joint - RZQS71~140, RZQ100~140 Triple Refnet Joint - RZQ200~250 Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ £30.00 £65.00 £84.00 £37.00 £47.00 £61.00 £308.00 £369.00 Notes: i) Accessories for fan coils and condensing units - refer to pair system pages Maximum Fuse size for Twin, Triple and Double Twin Outdoor Units Outdoor Units Power 71 100 125 140 200 RZQG & RZQSG Single Phase 20 amp 32 amp 32 amp 32 amp - - Three Phase 16 amp 20 amp 20 amp 20 amp - - Three Phase - - - - 20amp 20amp RZQ-C 250 Note: Max fuse size based on current price list series indoor units. Refer to data-book for more details. Price List Update: Valid from 1st January 2017 47 Server rooms & IT applications have some key differences to comfort cooling applications. Daikin has developed specific infrastructure cooling equipment to ensure efficient, reliable 24 hour cooling – now with ErP compliant Energy Labels. Comfort cooling Infrastructure cooling > 60-70% temperature control > 30-40% humidity control > 80-90% temperature control > 10-20% humidity control - Humidity is present - Balanced sensible and latent capacity - No or limited humidity - Pure sensible capacity How do comfort systems perform in infrastructure cooling applications? traditional solution dedicated solution Symmetric indoor-outdoor system combination Boosted capacity indoor system combination 12Te 10 kW RH% 12 Te 55 kW RH% 12 12 50 10 55 35 6 6 30 4 4 25 Time Relative Humidity: Capacity: Evaporating temp: 8 40 35 6 30 4 Capacity 4 8 40 Capacity 6 8 sensible capacity increase 45 Evaporating Temperature 8 Between 20-40% 50 10 10 45 Evaporating Temperature SPLIT, SKY AIR HEAT PUMPS Infrastructure Cooling 25 Time improved solution reduces over time reduced Boosted capacity indoors increase the heat transfer capacity at drops to compensate reduced capacity low relative humidity too low Te can lead to freeze-up Allows the system to operate with higher Te, guaranteeing prevention, causing system downtime continuous operation and reducing unwanted dehumidification Infrastructure cooling systems, with larger capacity indoor units can deliver higher sensible capacities Nominal Capacity Comfort Cooling Pairing Indoor Outdoor 22°C set point / 11C WB (35% RH) <25°C ambient Total Capacity / Sensible Capacity Sensible Ratio 22°C Set point / 16 WB (54% RH) 30°C ambient Total Capacity / Sensible Capacity Sensible Ratio Comfort Cooling Infrastructure Cooling Comfort Cooling Infrastructure Cooling Comfort Cooling Infrastructure Cooling 6.8kW 71 / 71 FAQ71C9 RZQG71L9V1 6.8kW 71 / 100 FAQ100C9 RZQG71L9V1 9.5kW 100 / 100 FHQ100CB RZQG100L9V1 9.5kW 100 / 140 FHQ140CB RZQG100L9V1 13.5kW 125 / 125 FHQ125CB RZQG125L9V1 12.0kW 125 / 140 FHQ140CB RZQG125L9V1 n/a 6.02 / 6.02 n/a 7.48 / 7.48 n/a 9.34 / 9.34 n/a 100% n/a 100% n/a 100% 7.76 / 5.32 7.8 / 5.71 10.8 / 7.44 9.70 / 7.54 13.6 / 9.3 12.12 / 9.00 69% 73% 69% 78% 68% 74% Daikin’s infrastructure cooling solution can deliver pure sensible capacity in low relative humidity applications. The solution uses indoor units of larger capacity than outdoor units, all with ErP Energy Labels. To make selection simple, tables are available showing total & sensible capacity at: > Ambient range in cooling from -15°C to +40°C > Dry build temperature range from 16°C to 27°C > Wet bulb temperature range from 11°C to 16°C For selection advice & capacity tables, please talk to your local Daikin office. 48 Residential, Commercial and Industrial FOR 2016 SPLIT, SKY AIR HEAT PUMPS NEW Sky Air – Duty Rotation In a infrastructure cooling application, it is normal to have a standby air conditioning unit(s). The standby unit will automatically operate in the event of a fault with one of the duty units. It is also normal to rotate the operation of the duty and standby units to ensure equal use of all units. Single remote controller required for up to 16 groups NEW BRC1E53A Remote Controller Daikins’ latest generation of hard wired remote controller now supports automatic duty rotation and standby operation on fault. > One controller for up to 16 systems > Programmable duty rotation changeover period > Automatic operation of standby unit on fault Model Description Related Fan Coil Trade Price BRC1E53A Premium wired remote controller with duty rotation function FBQ-D, FAQ-C9, FHQ-CB £79.00 RTD-10 Interface A single interface per group to carry out automatic duty rotation and standby operation on fault or high temperature. > Programmable duty rotation changeover period > Automatic operation of standby unit on fault and fixed high temperature > Dual level alarm volt free contact output 1 off RTD-10 and 1 off BRC1E53A required per group. Control of up to 8 groups possible Model Description Related Fan Coil Trade Price RTD-10 Control interface with duty rotation function All units with P1/P2 interface* £219.00 Automatic Changeover A single control panel to carry out automatic duty rotation and standby operation on fault or high temperature. > > > > > > 24hr duty rotation changeover period Automatic operation of standby unit on fault and adjustable high temperature Visual indication of unit status Fire alarm & condense pump interlocks Volt free contact alarm output Built-in remote controllers and interface PCBs Model Description Related Fan Coil Trade Price UK.PANEL 2SKYAIR UK.PANEL 3SKYAIR UK.PANEL 4SKYAIR Changeover panel for 2 SkyAir systems Changeover panel for 3 SkyAir systems Changeover panel for 4 SkyAir systems All units with P1/P2 interface* All units with P1/P2 interface* All units with P1/P2 interface* £1,801.00 £2,084.00 £3,354.00 * All SkyAir units, all VRV units and some Split units. For Split units check exact unit specification for compatibility Price List Update: Valid from 1st January 2017 49 Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways. In conjunction with Biddle, Daikin ERQ heat pump air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin ERQ heat pump inverter technology. Features and benefits: > Energy savings up to 72% compared with electric air curtains > Short payback times – less than 1.5 years > Wide capacity range for maximum application potential plus flexible control options > R-410A refrigerant, single and 3 phase > Wide operation range: -20~15.5°C in heating > Air curtain rectifier technology – deep penetrating airstream > Constant air velocity technology – all year round efficiency > European patent > 1.0, 1.5, 2.0 and 2.5 metre door widths > Door heights of up to 3.7 metres > C hoice of colour RAL9010:White or RAL9006:Grey Using a combination of rectifier technology, air velocity and temperature control, Daikin ERQ heat pump air curtains deliver greater comfort to staff and customers alike, all year round, in all weathers. BIDDLE AIR CURTAINS & ERQ PAIRS ARE LISTED ON ECA – For product listing refer to: https://etl.decc.gov.uk/etl/site/etl.html F = Free hanging model C = Cassette model R = Recessed model Biddle Comfort air curtain range Selection 3.7m 4m Maximum door height (m) SPLIT, SKY AIR HEAT PUMPS CYQS/M/L - DK - F/C/R 3.2m 2.8m 2.7m 3m 1) U se the Door Height graph to determine the Air Curtain size relevant to your application 3.1m 2.35m 2.3m 2.0m 2.5m 2m 2) W hen you know the size (S/M/L), refer to specific tables to select the model for your required door width 1m S M S L M L S M L 3) S elect outdoor unit to pair door curtain, based on efficiency and power source Installation condition Ideal for doors in a shopping centre or revolving door entrance S For more exposed doors with some direct wind, suitable for ground floor applications For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level Biddle Standard Air Curtain (Small) – Door height 2m to 2.7m Maximum Door Width Mounting Height *2 Max / Min Model Name Type Heating Capacity Delta T Inlet = room temperature Power Input (50Hz) Fan only / Heating Dimensions Height Width Depth Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply m m *=F speed 3 kW speed 3 °K kW mm mm mm kg mm speed 3 m3/sec speed 3 dBA inch (mm) Phase / Hz / V Trade Unit Price 270 1,500 590 66 1.50 2.7 / 2.0 CYQS150DK80*BN *=C 9.00 15 0.35 / 0.35 270 1,500 821 83 white RAL9010 420 0.485 49 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 £3,025.00 £3,025.00 2.00 2.7 / 2.0 CYQS200DK100*BN *=C 11.60 15 0.46 / 0.46 270 2,000 821 102 white RAL9010 420 0.647 50 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 *=R *=F 270 1,548 561 88 270 2,000 590 83 £3,188.00 £3,680.00 £3,680.00 2.50 2.7 / 2.0 CYQS250DK140*BN *=C 16.20 16 0.58 / 0.58 270 2,500 821 129 white RAL9010 420 0.808 51 R-410A 3/8 (9.5) / 3/4 (19) 1 / 50 / 230 *=R *=F 270 2,048 561 108 270 2,500 590 107 £3,990.00 £4,131.00 £4,131.00 50 Residential, Commercial and Industrial ERQ100AV1 ERQ100 AV1 ERQ125AV1 / AW1 270 2,548 561 137 £4,471.00 * 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed Condensing Unit Selection for Small Door Curtain Standard Efficiency Improved Efficiency High Efficiency *=R ERQ125AV1 / AW1 ERQ140AV1 ERQ200AV1 SPLIT, SKY AIR HEAT PUMPS M Biddle Standard Air Curtain (Medium) – Door height 2.3m to 3.2m Maximum Door Width m 1.00 1.50 2.00 2.5 Mounting Height *2 Max / Min m 3.2 / 2.3 3.2 / 2.3 3.2 / 2.3 3.2 / 2.3 Model Name CYQM100DK80*BN Type *=F Heating Capacity Delta T Inlet = room temperature Power Input (50Hz) Fan only / Heating Dimensions Height Width Depth Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply speed 3 kW speed 3 °K kW mm mm mm kg mm speed 3 m3/sec speed 3 dBA inch (mm) Phase / Hz / V Trade Unit Price *=C CYQM150DK80*BN *=R 9.20 17 0.37 / 0.37 270 270 270 1,000 1,000 1,048 590 821 561 57 68 66 white RAL9010 420 0.446 50 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 *=F *=C *=R 11.00 14 0.56 / 0.56 270 270 270 1,500 1,500 1,548 590 821 561 73 88 93 white RAL9010 420 0.669 51 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 CYQM200DK100*BN *=F *=C CYQM250DK140*BN *=R 13.40 13 0.75 / 0.75 270 270 270 2,000 2,000 2,048 590 821 561 94 111 117 white RAL9010 420 0.892 53 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 *=F *=C *=R 19.90 15 0.94 / 0.94 270 270 270 2,500 2,500 2,548 590 821 561 108 136 144 white RAL9010 420 1.115 54 R-410A 3/8 (9.5) / 3/4 (19) 1 / 50 / 230 £2,933.00 £2,933.00 £3,027.00 £4,773.00 £4,773.00 £4,927.00 £4,376.00 £4,376.00 £4,685.00 £5,009.00 £5,009.00 £5,343.00 * 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed Condensing Unit Selection form Medium Door Curtain Standard Efficiency Improved Efficiency High Efficiency L ERQ100AV1 ERQ100AV1 ERQ125AV1 / AW1 ERQ100AV1 ERQ125AV1 / AW1 ERQ140AV1 ERQ200AW1 ERQ250AW1 Biddle Standard Air Curtain (Large) – Door height 2.5m to 3.7m Maximum Door Width m 1.00 1.50 2.00 2.5 Mounting Height *2 Max / Min m 3.7 / 2.5 3.7 / 2.5 3.7 / 2.5 3.7 / 2.5 Model Name CYQL100DK125*BN Type *=F Heating Capacity Delta T Inlet = room temperature Power Input (50Hz) Fan only / Heating Dimensions Height Width Depth Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply speed 3 kW speed 3 °K kW mm mm mm kg mm speed 3 m3/sec speed 3 dBA inch (mm) Phase / Hz / V Trade Unit Price *=C CYQL150DK200*BN *=R 15.60 15 0.75 / 0.75 370 370 370 1,000 1,000 1,048 774 1105 745 76 81 83 white RAL9010 520 0.861 53 R-410A 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 *=F *=C *=R 23.30 15 1.13 / 1.13 370 370 370 1,500 1,500 1,548 774 1105 745 100 118 141 white RAL9010 520 1.292 54 R-410A 3/8 (9.5) / 3/4 (19) 1 / 50 / 230 CYQL200DK250*BN *=F *=C CYQL250DK250*BN *=R 29.40 14 1.50 / 1.50 370 370 370 2,000 2,000 2,048 774 1105 745 126 151 155 white RAL9010 520 1.722 56 R-410A 3/8 (9.5) / 7/8 (22.2) 1 / 50 / 230 *=F *=C *=R 31.10 12 1.88 / 1.88 370 370 370 2,500 2,500 2,548 774 1105 745 157 190 196 white RAL9010 520 2.153 57 R-410A 3/8 (9.5) / 7/8 (22.2) 1 / 50 / 230 £3,346.00 £3,346.00 £3,356.00 £4,773.00 £4,773.00 £4,927.00 £5,925.00 £5,925.00 £6,233.00 £6,915.00 £6,915.00 £7,297.00 * 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed Condensing Unit Selection for Large Door Curtain Standard Efficiency Improved Efficiency High Efficiency ERQ125AV1 / AW1 ERQ140AV1 ERQ200AW1 ERQ200AW1 ERQ250AW1 ERQ250AW1 ERQ250AW1 ERQ Condensing Units Single Phase Dimensions Height Width Depth Weight Pipe Run Airflow Direction Trade Unit Price mm mm mm kg m 3 Phase ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1 1345 900 320 120 55 Side blow 1345 900 320 120 55 Side blow 1345 900 320 120 55 Side blow 1680 635 765 159 55 Top blow 1680 930 765 187 55 Top blow 1680 930 765 240 55 Top blow £1,595.00 £1,778.00 £2,131.00 £1,813.00 £3,130.00 £3,261.00 Accessories for all Door Curtains Notes: Accessory Ref Description Trade Price BRC1E53A KRCS01-1 RTD-20/UK.FB2 Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock Remote room mounted temperature sensor Energy control PCB for Sky Air and VRV £79.00 £48.00 £262.00 i) To calculate the price for a complete system, add together the prices for door curtain, ERQ and remote controller. 1 off CYQL100DK125FBN £3,346.00 1 off 1 off ERQ125AV1 BRC1E52 £1,778.00 £79.00 Total £5,203.00 Price List Update: Valid from 1st January 2017 51 SPLIT, SKY AIR HEAT PUMPS Central Ducted Solutions Even without the benefit of individual room control, the system can provide a flexible energy saving answer over traditional methods through the incorporation of inverter control and heat pump technology. For central ducted distribution systems Daikin has the solution for providing cooling and heating of the air, enabling optimal comfort and efficiency. The following pages include Packaged Heat Pump Rooftop systems, with optional economisers, to heat pump condensing units and connection kits for use with other manufacturers heating and cooling coils. Air handling unit Liquid pipe Liquid pipe Gas pipe Gas pipe Field supply EV kit Control box F1,F2 communication DDC control (control w) Air Cooled Heat Pump Inverter Condensing Unit Kit for DX Coil Flexible control possibilities: Control w: Full external control from 3rd party temperature controller with volt free remote enable contact and linear variable capacity control output (3rd party DDC Controller required). A range of R410A inverter condensing units for application with air handling units: > Inverter controlled heat pump units > Large capacity range (from 6.3 to 61.6 kW) > Ventilation and air conditioning in 1 solution > EKEXV-kit & control boxes are designed for outdoor installation and can be wall mounted > Per EKEXV-kit/control box, only 1 air handling unit coil can be connected > Outdoor unit operation range: -5°CDB ~ 43°CDB in cooling > For connectivity to VRV IV systems, please consult with your local Daikin representative Outdoor unit Trade Unit Price 3ph ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1 Trade Acc. Price £1,595.00 £1,778.00 £2,131.00 £1,813.00 £3,130.00 £3,261.00 Control z (BRC1D52 required): Control via Daikin BRC1D52 remote controller and return air or remote sensor (KRCS01-1 optional). A volt free remote enable contact is required to confirm fan operation status. For re-circ applications only. Control box control z Expansion Valve Kit control y, w control y, w class 63 EKEQDCB EKEQFCBA EKEQMCBA EKEXV63 1ph Control y: External control from 3rd party temperature controller with volt free remote enable contact. Fixed evaporating temperature selection, range: +3°C to +10°C. P P P P P P P P P P P P £326.00 £376.00 class 80 EKEXV80 class 100 class 125 class 140 class 200 class 250 VRV only P P P P - P P P P P - P P P P P P P P P P P P P P P VRV only VRV only £580.00 £73.00 £75.00 £82.00 £89.00 £103.00 £123.00 £137.00 £152.00 £167.00 For all AHU application selections with ERQ and VRV systems, please consult with a member of Daikin staff to ensure correct selection and AHU coil design parameters. Residential, Commercial and Industrial class 500 P P P - P: Pair Combination depending on air handling units coils volume 52 class 400 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500 SPLIT, SKY AIR HEAT PUMPS ERAD-E Large Condensing Units Large Condensing Unit (Standard Noise Level) ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS Capacity EER Refrigerant Dimensions Weight Electrical Details Nominal Cooling kW 121 2.89 144 2.82 165 2.87 196 3.01 219 2.97 Length Height Width mm mm mm kg V Hz ph 2170 2.27 1290 1564 2170 2.27 1290 1587 3070 2.27 1290 1698 3070 2.27 1290 1739 3070 2.27 1290 1886 252 3.29 306 3.3 370 3.03 435 2.96 488 3.03 3070 2.27 1290 1928 3070 2220 2240 2355 3070 2220 2240 2559 3070 2220 2240 2642 3070 2220 2240 2677 POA POA POA POA POA R134a Power Supply 400 50 3 Trade Unit Price POA POA POA POA POA Large Condensing Unit (Low Noise Level) ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL Capacity EER Refrigerant Dimensions Weight Electrical Details Nominal Cooling kW 116 2.74 137 2.61 159 2.76 187 2.82 209 2.83 Length Height Width mm mm mm kg V Hz ph 2170 2.27 1290 1712 2170 2.27 1290 1738 3070 2.27 1290 1851 3070 2.27 1290 1897 3070 2.27 1290 2046 243 3.11 295 3.22 352 2.88 409 2.72 462 2.76 3070 2.27 1290 2091 3070 2220 2240 2534 3070 2220 2240 2741 3070 2220 2240 2834 3070 2220 2240 2873 POA POA POA POA POA R134a Power Supply Trade Unit Price 400 50 3 POA POA POA POA POA Features: ERAD-E are a range of cooling only R134a condensing units for pair application with air handling units > Large capacity range 100 kW to 410 kW > Superior control logic using the new MicroTech III controller > Single circuit units > Screw compressor with capacity control down to 25% > Available in both standard and low noise configurations Please contact your sales office for further information on these products UATYQ Rooftop Packaged Unit – Heat Pump UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 Capacity Dimensions Weight Air Flow Rate External Static Air Flow Rate Refrigerant Sound Power Level Drain size Electrical Details Nominal Cooling Nominal Heating Height Width Depth Indoor Indoor Outdoor kW kW mm mm mm kg m3/sec Pa m3/sec 27.34 24.91 1150 1638 2063 445 1.55 147 0 35.58 34.79 1028 2209 2113 580 2.03 147 0 44.72 41.79 1130 2209 2113 610 2.67 147 0 55.69 53.93 1048 2209 2670 830 3.167 206 0 66.82 61.69 1302 2209 2670 880 3.417 206 0 72.60 69.61 1302 2209 2670 1020 3.883 206 0 UATYPC10AY1 UATYPC12AY1 101.10 102.30 1974 2252 3180 1510 5.20 109.60 126.30 1974 2252 3180 1600 5.90 - 0 R410A Outdoor Power Supply Running Current Starting Current Max Fuse Size dBA mm V Hz Phase A A A Trade Unit Price Economiser 82 83 0 R407C 83 87 90 90 80 80 41.6 144 50 £10,598.00 46.5 148 50 £11,341.00 74.2 175 , 215 125 £15,142.00 82.9 215x2 125 £16,449.00 25.4 (OD) 400 50 3ph 20.5 118 32 £5,229.00 26.4 93 40 £5,444.00 33.1 123 40 £8,957.00 39.4 137 50 £9,856.00 ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1 Trade Unit Price £922.00 £969.00 £1,016.00 £1,065.00 £1,120.00 £1,175.00 Notes: i) Minimum Ambient operating conditions UATYQ250~700 UATYPC10~12 Cooling Heating 0°C 20°C -15°C -15°C ii) Supplied with remote controller as standard v) Please check stock & delivery period for all model sizes iii) Economiser option is supplied as a kit for site assembly vi) Standard delivery for all units does not include off-loading to kerbside iv) Low ambient kit for models UATYPC available on request vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site viii) All other units require crane or HIAB. Prices for HIAB available on request Price List Update: Valid from 1st January 2017 53 SPLIT, SKY AIR HEAT PUMPS VRV Daikin UK Price List Update VRV Indoor Units 56 VRV Fan Coil Units 56 Hot Water Connection 63 Air Curtains 66 Outdoor Condensing Units 68 VRV Condensing Unit Services 68 VRV Condensing Units – S-series (Mini) 70 VRV Condensing Units – i-series 74 VRV Condensing Units – Heat Pump 76 VRV Condensing Units – Heat Recovery 80 VRV Condensing Units – Replacement VRV-Q 84 DNSS Remote Monitoring 90 VRV-Q Warranty 91 Water Cooled VRV 94 Accessories 96 VRV Heat Recovery Branch Selector Boxes 96 Intelligent Manager Building Management System 98 Controls and Apps 100 Refrigerant Leak Detection 107 VRV Cloud Energy Reporting 108 Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 FXFQ-A VRV Fan Coil – Roundflow Cassette Indoor Units Capacity VRV Air Flow Rate Dimensions Weight Decoration Panel Decoration Panel Decoration Panel Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low Height x Width x Depth Model Colour Dimensions H x W x D Weight Model Colour Dimensions H x W x D Weight Model Colour Dimensions H x W x D Weight Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Sound Power Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec mm kg FXFQ20A FXFQ25A 1.80 1.60 2.20 2.50 0.208 0.177 0.147 2.30 1.90 2.80 3.20 0.208 0.177 0.147 19 19 0.3 0.3 31.0 29.0 28.0 49 1/4 (6.4) 1/2 (12.7) 31.0 29.0 28.0 49 1/4 (6.4) 1/2 (12.7) 2.90 3.60 4.50 5.70 7.20 9.00 2.60 3.00 3.60 4.60 5.80 6.90 3.60 4.50 5.60 7.10 9.00 11.20 4.00 5.00 6.30 8.00 10.00 12.50 0.208 0.227 0.250 0.275 0.380 0.442 0.177 0.193 0.213 0.225 0.293 0.325 0.147 0.158 0.175 0.175 0.207 0.207 204x840x840 246x840x840 19 20 21 21 24 24 Roundflow BYCQ140D (standard panel) Pure White (RAL 9010) 50x950x950 5.4 Roundflow with white louvres BYCQ140DW Pure White (RAL 9010) 50x950x950 5.4 Roundflow self cleaning BYCQ140DG Pure White (RAL 9010) 130x950x950 10.3 0.3 0.3 0.4 0.4 0.6 0.8 1 / 50 / 230 5.0 31.0 33.0 33.0 35.0 38.0 43.0 29.0 31.0 31.0 33.0 34.0 37.0 28.0 29.0 29.0 30.0 30.0 30.0 49 51 51 53 55 60 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) £790.00 £806.00 £824.00 mm kg mm kg mm kg amps Phase / Hz / V amps dBA dBA dBA dBA inch (mm) inch (mm) Trade Unit Price FXFQ32A FXFQ40A £890.00 FXFQ50A £934.00 FXFQ63A £985.00 FXFQ80A £1,050.00 FXFQ100A £1,140.00 FXFQ125A 11.30 8.60 14.00 16.00 0.550 0.442 0.332 288x840x840 26 1.3 45.0 41.0 36.0 61 3/8 (9.5) 5/8 (15.9) £1,420.00 Notes: i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item ii) BYCQ140D = pure white panel with grey louvers , BYCQ140DW = pure white standard panel with white louvers, BYCQ140DG = Pure white auto cleaning panel The BYCQ140DW has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt iii) For accessories please refer to pages 96 - 108 FXZQ-A VRV Fan Coil – 600x600 Fully Flat Cassette Indoor Units Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Air Flow Rate High Nom Low Dimensions (with Decoration Panel) HxWxD Weight (with Decoration Panel) Decoration Panel Dimensions Weight Decoration Panel Dimensions Weight Decoration Panel Dimensions Weight Electrical Details Running Current Power Supply Fuse Rating Sound Level Sound Pressure High Nom Low Sound Power Piping Connections Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec mm kg FXZQ15A FXZQ20A 1.40 1.30 1.70 1.90 0.142 0.117 0.108 1.80 1.50 2.20 2.50 0.145 0.125 0.108 15.5 (18.3) mm kg mm kg mm kg amps Phase / Hz / V amps dBA dBA dBA dBA inch (mm) inch (mm) Trade Unit Price 0.3 31.5 28.0 25.5 49 1/4 (6.4) 1/2 (12.7) £750.00 FXZQ25A £767.00 £783.00 Notes: i) Cassette prices include Fully Flat decoration panel in fresh white. Other colour panels available on request. 56 Residential, Commercial and Industrial FXZQ32A FXZQ40A 2.30 2.90 3.60 1.80 2.10 2.90 2.80 3.60 4.50 3.20 4.00 5.00 0.150 0.167 0.192 0.133 0.142 0.158 0.108 0.117 0.133 260 (306) x 575 (620) x 575 (620) 15.5 (18.3) 15.5 (18.3) 16.5 (19.3) 16.5 (19.3) Fully Flat in white (N9.5) BYFQ60CW (standard panel) 46 x 620 x 620 2.8 Fully Flat in white (N9.5) with silver BYFQ60CS (standard panel) 46 x 620 x 620 2.8 Old style panel BYFQ60B3 (White RAL9010) 55 x 700 x 700 2.7 0.3 0.3 0.4 0.4 1 / 50 / 230 5 32.0 33.0 33.5 37.0 29.5 30.0 30.0 32.0 25.5 25.5 26.0 28.0 49 50 51 54 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) ii) Dimensions include control box iii) For accessories please refer to pages 96 - 108 £800.00 £859.00 FXZQ50A 4.50 3.60 5.60 6.30 0.242 0.208 0.167 18.5 (21.3) 0.6 43.0 40.0 33.0 60 1/4 (6.4) 1/2 (12.7) £943.00 FXCQ-A VRV Fan Coil – 2 Way Blow Cassette UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Air Flow Rate High Nom Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Decoration Panel Electrical Details Running Current Power Supply Fuse Rating Sound Level Sound Pressure High Nom Low Piping Connections Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec mm mm mm kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) Trade Unit Price FXCQ20A FXCQ25A FXCQ32A FXCQ40A 1.8 1.7 2.2 2.5 0.175 0.150 0.125 305 (360) 775 (1070) 620 (700) 19 (29) 2.3 2.9 2 2.3 2.8 3.6 3.2 4.0 0.192 0.192 0.158 0.158 0.133 0.133 305 (360) 305 (360) 775 (1070) 775 (1070) 620 (700) 620 (700) 19 (29) 19 (29) BYBCQ40H 0.3 0.3 3.6 2.9 4.5 5.0 0.200 0.175 0.142 305 (360) 775 (1070) 620 (700) 19 (29) FXCQ50A FXCQ63A 32.0 30.0 28.0 1/4 (6.4) 1/2 (12.7) 34.0 31.0 29.0 1/4 (6.4) 1/2 (12.7) 34.0 32.0 30.0 1/4 (6.4) 1/2 (12.7) 4.5 5.7 3.5 4.9 5.6 7.1 6.3 8.0 0.250 0.267 0.217 0.233 0.175 0.192 305 (360) 305 (360) 990 (1285) 990 (1285) 620 (700) 620 (700) 22 (33) 25 (36) BYBCQ63H 0.3 0.4 0.5 1 / 50 / 230 5 36.0 37.0 39.0 33.0 35.0 37.0 31.0 31.0 32.0 1/4 (6.4) 1/4 (6.4) 3/8 (9.5) 1/2 (12.7) 1/2 (12.7) 5/8 (15.9) £890.00 £905.00 £914.00 £1,010.00 0.3 £1,105.00 £1,147.00 FXCQ80A FXCQ125A 7.2 11.3 5.7 8.7 9.0 14.0 10.0 16.0 0.433 0.533 0.375 0.458 0.308 0.375 305 (360) 305 (360) 1445 (1740) 1445 (1740) 620 (700) 620 (700) 33 (46) 38 (51) BYBCQ125H 0.6 1.1 42.0 38.0 33.0 3/8 (9.5) 5/8 (15.9) 46.0 42.0 38.0 3/8 (9.5) 5/8 (15.9) £1,316.00 £1,580.00 Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 96 - 108 FXKQ-MA VRV Fan Coil – 1 Way Blow Corner Cassette Indoor Units Capacity UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Air Flow Rate High Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Decoration Panel Electrical Details Running Current Power Supply Fuse Rating Sound Level Sound Pressure High Low Piping Connections Liquid Gas Trade Unit Price kW kW kW kW m3/sec m3/sec mm mm mm kg amps Phase / Hz / V amps dBA dBA inch (mm) inch (mm) FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA 2.3 2.2 2.8 3.2 0.183 0.150 215 (285) 1110 (1240) 710 (800) 31 (39.5) 2.9 2.5 3.6 4.0 0.183 0.150 215 (285) 1110 (1240) 710 (800) 31 (39.5) BYK45F 0.3 3.6 2.8 4.5 5.0 0.217 0.167 215 (285) 1110 (1240) 710 (800) 31 (39.5) 0.3 5.7 4.5 7.1 8.0 0.300 0.250 215 (285) 1310 (1440) 710 (800) 34 (43.5) BYK71F 0.5 0.3 1 / 50 / 230 5 38.0 33.0 1/4 (6.4) 1/2 (12.7) 38.0 33.0 1/4 (6.4) 1/2 (12.7) 40.0 34.0 1/4 (6.4) 1/2 (12.7) 42.0 37.0 3/8 (9.5) 5/8 (15.9) £985.00 £996.00 £1,088.00 £1,234.00 Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 96 - 108 Price List Update: Valid from 1st January 2017 57 VRV Indoor Units Capacity FXSQ-A VRV Fan Coil – Concealed Ceiling Unit (Medium Static) Indoor Units Capacity VRV Air Flow Rate External Static Pressure Dimensions Weight Electrical Details Sound Level Piping Connections FXSQ15A FXSQ20A FXSQ25A FXSQ32A FXSQ40A FXSQ50A FXSQ63A FXSQ80A FXSQ100A FXSQ125A FXSQ140A UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low High Low Height x Width x Depth kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Sound Power Liquid Gas kg 23.5 23.5 23.5 24.0 28.5 29.0 35.5 36.5 46.0 47.0 amps 0.4 0.4 0.4 0.4 0.8 0.8 0.9 1.0 1.5 2.0 Phase / Hz / V 1 / 50 / 230 amps 5 dBA 29.5 30.0 30.0 31.0 35.0 35.0 33.0 35.0 36.0 39.0 41.5 dBA 28.0 28.0 28.0 29.0 32.0 32.0 30.0 32.0 34.0 36.0 38.0 dBA 25.0 25.0 25.0 26.0 29.0 29.0 27.0 29.0 31.0 33.0 34.0 dBA 54.0 54.0 54.0 55.0 60.0 60.0 59.0 61.0 61.0 64.0 64.0 inches (mm) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) inches (mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) Trade Unit Price 1.4 1.1 1.7 1.9 0.145 0.125 0.108 150 30 1.8 2.3 1.4 1.8 2.2 2.8 2.5 3.2 0.150 0.150 0.125 0.125 0.108 0.108 150 150 30 30 245 x 550 x 800 £604.00 £622.00 2.9 2.3 3.6 4.0 0.158 0.133 0.117 150 30 £639.00 £647.00 3.6 4.5 2.9 3.6 4.5 5.6 5.0 6.3 0.250 0.253 0.208 0.208 0.183 0.183 150 150 30 30 245 x 700 x 800 £689.00 £718.00 5.7 7.2 4.5 5.7 7.1 9.0 8.0 10.0 0.350 0.383 0.300 0.325 0.250 0.267 150 150 30 40 245 x 1000 x 800 £741.00 9.0 11.3 7.2 8.9 11.2 14.0 12.5 16.0 0.533 0.600 0.450 0.525 0.383 0.433 150 150 40 50 245 x 1400 x 800 £845.00 12.9 10.2 16.0 18.0 0.650 0.567 0.467 150 50 245 x 1550 x 800 51.0 1.9 £936.00 £1,072.00 £1,179.00 Notes: i) For accessories please refer to pages 96 - 108 ii) Preliminary Data – May be subject to change FXMQ-P7 Concealed Ceiling Unit (High Static) Indoor Units Capacity Air Flow Rate External Static pressure Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low High Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Sound Power Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm kg amps Phase / Hz / V amps dBA dBA dBA dBA inch (mm) inch (mm) Trade Unit Price Notes: i) For accessories please refer to pages 96 - 108 58 Residential, Commercial and Industrial FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7 4.5 4.1 5.6 6.3 0.300 0.275 0.250 200 100 7.2 6.1 9.0 10.0 0.417 0.375 0.333 200 100 9 7.3 11.2 12.5 0.533 0.458 0.383 200 100 11.3 9.2 14 16 0.650 0.558 0.467 200 100 35 1.4 5.7 4.9 7.1 8.0 0.325 0.297 0.267 200 100 300 x 1000 x 700 35 1.4 46 2.3 46 2.9 41.0 39.0 37.0 61.0 1/4 (6.4) 1/2 (12.7) 42.0 40.0 38.0 64.0 3/8 (9.5) 5/8 (15.9) 35 1.7 1 / 50 / 230 5 43.0 41.0 39.0 67.0 3/8 (9.5) 5/8 (15.9) 43.0 41.0 39.0 65.0 3/8 (9.5) 5/8 (15.9) 44.0 42.0 40.0 70.0 3/8 (9.5) 5/8 (15.9) £1,109.00 £1,162.00 £1,221.00 £1,354.00 £1,549.00 300 x 1400 x 700 FXDQ-A Slim Concealed Ceiling Unit Air Flow Rate External Static Pressure Dimensions Weight Electrical Details Sound Level Piping Connections FXDQ15A UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low High Low Height x Width x Depth kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Liquid Gas kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) Trade Unit Price 1.4 1.3 1.7 1.9 0.125 0.117 0.107 30 10 FXDQ20A FXDQ25A 1.8 2.3 1.6 1.9 2.2 2.8 2.5 3.2 0.133 0.133 0.120 0.120 0.107 0.107 30 30 10 10 200 x 750 x 620 FXDQ32A FXDQ40A FXDQ50A 26 0.5 26 0.5 33.0 31.0 27.0 1/4 (6.4) 1/2 (12.7) 22 0.4 1 / 50 / 230 5 33.0 31.0 27.0 1/4 (6.4) 1/2 (12.7) 34.0 32.0 28.0 1/4 (6.4) 1/2 (12.7) 35.0 33.0 29.0 1/4 (6.4) 1/2 (12.7) 36.0 34.0 30.0 3/8 (9.5) 5/8 (15.9) £621.00 £630.00 £670.00 £697.00 £719.00 22 0.4 22 0.4 32.0 31.0 27.0 1/4 (6.4) 1/2 (12.7) 33.0 31.0 27.0 1/4 (6.4) 1/2 (12.7) £585.00 £603.00 3.6 4.5 2.8 3.5 4.5 5.6 5.0 6.3 0.175 0.208 0.158 0.183 0.142 0.167 44 44 15 15 200 x 950 x 620 FXDQ63A 5.7 4.3 7.1 8.0 0.275 0.242 0.217 44 15 200 x 1150 x 620 29 0.6 22 0.4 2.9 2.2 3.6 4.0 0.133 0.120 0.107 30 10 VRV Indoor Units Capacity Notes: i) For accessories please refer to pages 96 - 108 ii) Fan coils supplied as standard with factory fitted filter FXDQ-M9 Small Concealed Ceiling Unit Indoor Units Capacity Air Flow Rate Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Nom Sound Power Liquid Gas Trade Unit Price kW kW kW kW m3/sec m3/sec mm kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) FXDQ20M9 FXDQ25M9 1.8 1.6 2.2 2.5 0.112 0.087 2.3 1.9 2.8 3.2 0.123 0.097 230 x 652 x 502 17 0.2 17 0.2 1 / 50 / 230 5 37.0 32.0 50 1/4 (6.4) 1/2 (12.7) 37.0 32.0 50 1/4 (6.4) 1/2 (12.7) £603.00 £621.00 Notes: i) For accessories please refer to pages 96 - 108 ii) Fan coils supplied as standard with factory fitted filter Price List Update: Valid from 1st January 2017 59 FXMQ-MB VRV Fan Coil – Concealed Ceiling Unit (Ultra High Static) Indoor Units Capacity VRV Air Flow Rate External Static pressure Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low High Nom Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Low Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm kg amps Phase / Hz / V amps dBA dBA inch (mm) inch (mm) FXMQ200MB FXMQ250MB 18.0 14.9 22.4 25.0 0.967 0.900 0.833 270 160 22.5 18.5 28.0 31.5 1.200 1.117 1.033 270 170 470 x 1380 x 1100 132 10.3 132 10.3 1 / 50 / 230 13 Trade Unit Price 48.0 45.0 3/8 (9.5) 3/4 (19) 48.0 45.0 3/8 (9.5) 7/8 (22.2) £2,706.00 £2,769.00 Notes: i) For accessories please refer to pages 96 - 108 FXAQ-P VRV Fan Coil – Wall Mounted Indoor Units Capacity Air Flow Rate Dimensions Weight Electrical Details Sound Level Piping Connections FXAQ15P UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Low Liquid Gas kW kW kW kW m3/sec m3/sec mm kg amps Phase / Hz / V amps dBA dBA inch (mm) inch (mm) Trade Unit Price Notes: i) For accessories please refer to pages 96 - 108 60 Residential, Commercial and Industrial 1.4 1.4 1.7 1.9 0.117 0.075 11 0.3 FXAQ20P FXAQ25P 1.8 2.3 1.8 2.0 2.2 2.8 2.5 3.2 0.125 0.133 0.075 0.083 290 x 795 x 238 11 11 0.3 0.4 FXAQ32P FXAQ40P FXAQ50P FXAQ63P 2.9 2.4 3.6 4.0 0.142 0.092 3.6 3.3 4.5 5.0 0.200 0.150 5.7 4.6 7.1 8.0 0.317 0.233 14 0.4 4.5 3.7 5.6 6.3 0.250 0.200 290 x 1050 x 238 14 0.5 39.0 34.0 1/4 (6.4) 1/2 (12.7) 42.0 36.0 1/4 (6.4) 1/2 (12.7) 47.0 39.0 3/8 (9.5) 5/8 (15.9) £501.00 £528.00 £582.00 34.0 29.0 1/4 (6.4) 1/2 (12.7) 35.0 29.0 1/4 (6.4) 1/2 (12.7) 36.0 29.0 1/4 (6.4) 1/2 (12.7) 11 0.4 1 / 50 / 230 5 37.5 29.0 1/4 (6.4) 1/2 (12.7) £457.00 £471.00 £483.00 £488.00 14 0.6 FXHQ-A Indoor Units Capacity Air Flow Rate Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec mm kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) Trade Unit Price FXHQ32A FXHQ63A FXHQ100A 2.9 2.3 3.6 4.0 0.233 0.200 0.167 235 x 960 x 690 24 0.8 9 6.3 11.2 12.5 0.492 0.400 0.317 235 x 1590 x 690 39 1.7 36.0 34.0 31.0 1/4 (6.4) 1/2 (12.7) 5.7 4.4 7.1 8.0 0.333 0.283 0.233 235 x 1270 x 690 33 0.8 1 / 50 / 230 5 37.0 35.0 34.0 3/8 (9.5) 5/8 (15.9) £943.00 £1,045.00 £1,296.00 VRV VRV Fan Coil – Ceiling Suspended 44.0 37.0 34.0 3/8 (9.5) 5/8 (15.9) Notes: i) For accessories please refer to pages 96 - 108 FXUQ-A VRV Fan Coil – Under Ceiling Cassette Indoor Units Capacity Air Flow Rate Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Liquid Gas Trade Unit Price kW kW kW kW m3/sec m3/sec m3/sec mm kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) FXUQ71A FXUQ100A 6.4 5.2 8.0 9.0 0.375 0.325 0.267 9.0 7.0 11.2 12.5 0.517 0.433 0.350 198 x 950 x 950 26 0.6 27 1.4 1 / 50 / 230 5 40.0 38.0 36.0 3/8 (9.5) 5/8 (15.9) 47.0 44.0 40.0 3/8 (9.5) 5/8 (15.9) £1,305.00 £1,391.00 Notes: i) For accessories please refer to pages 96 - 108 Price List Update: Valid from 1st January 2017 61 FXLQ-P VRV Fan Coil – Floor Mounted Cased Indoor Units Capacity VRV Air Flow Rate Dimensions Weight Electrical Details Sound Level Piping Connections FXLQ20P UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Low Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Low Liquid Gas kW kW kW kW m3/sec m3/sec mm kg amps Phase / Hz / V amps dBA dBA inch (mm) inch (mm) Trade Unit Price FXLQ25P 1.8 2.3 1.5 1.8 2.2 2.8 2.5 3.2 0.117 0.117 0.100 0.100 600 x 1000 x 232 27 27 0.3 0.3 FXLQ32P FXLQ40P 35.0 32.0 1/4 (6.4) 1/2 (12.7) 35.0 32.0 1/4 (6.4) 1/2 (12.7) 2.9 3.6 2.2 2.7 3.6 4.5 4.0 5.0 0.133 0.183 0.100 0.142 600 x 1140 x 232 32 32 0.6 0.6 1 / 50 / 230 5 35.0 38.0 32.0 33.0 1/4 (6.4) 1/4 (6.4) 1/2 (12.7) 1/2 (12.7) £723.00 £735.00 £749.00 FXLQ50P FXLQ63P 4.5 5.7 3.4 4.2 5.6 7.1 6.3 8.0 0.233 0.267 0.183 0.200 600 x 1420 x 232 38 38 0.6 0.6 39.0 34.0 1/4 (6.4) 1/2 (12.7) 40.0 35.0 3/8 (9.5) 5/8 (15.9) £776.00 £785.00 £831.00 Notes: i) For accessories please refer to pages 96 - 108 FXNQ-A VRV Fan Coil – Concealed Floor Standing Unit Indoor Units Capacity Air Flow Rate External Static Pressure Dimensions Weight Electrical Details Sound Level Piping Connections UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating High Nom Low High Nominal Height x Width x Depth Running Current Power Supply Fuse Rating Sound Pressure High Nom Low Liquid Gas kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm kg amps Phase / Hz / V amps dBA dBA dBA inch (mm) inch (mm) Trade Unit Price FXNQ20A FXNQ25A FXNQ32A FXNQ40A FXNQ50A FXNQ63A 1.8 1.6 2.2 2.5 0.133 0.120 0.107 41 10 2.3 1.9 2.8 3.2 0.133 0.120 0.107 41 10 620 x 750 x 200 23.5 0.4 2.9 2.2 3.6 4.0 0.133 0.120 0.107 42 10 3.6 2.8 4.5 5.0 0.175 0.158 0.142 52 15 4.5 3.5 5.6 6.3 0.208 0.183 0.167 59 15 23.5 0.4 27.5 0.5 27.5 0.5 5.7 4.3 7.1 8 0.275 0.242 0.217 55 15 620 x 1150 x 200 32.0 0.6 23.5 0.4 620 x 950 x 200 1 / 50 / 230 5 30.0 28.5 27.0 1/4 (6.4) 1/2 (12.7) 30.0 28.5 27.0 1/4 (6.4) 1/2 (12.7) 30.0 28.5 27.0 1/4 (6.4) 1/2 (12.7) 32.0 30.0 28.0 1/4 (6.4) 1/2 (12.7) 33.0 31.0 29.0 1/4 (6.4) 1/2 (12.7) 35.0 33.0 32.0 3/8 (9.5) 5/8 (15.9) £675.00 £686.00 £700.00 £725.00 £733.00 £778.00 Increased static pressure – up to 59Pa Notes: i) For accessories please refer to pages 96 - 108 ii) Supplied with removable feet 62 Residential, Commercial and Industrial HXY-A8 Hot Water Generation – VRV Heat Pump Systems VRV Producing hot water from a heat pump system provides extremely low cost heating and cooling of water. Temperatures between 5°C to 45°C can be achieved allowing water temperature control for multiple applications without the need for a separate system. HXY-A8 Features and benefits: > Highly efficient space heating/cooling > Air to water connection to VRV for applications such as underfloor, AHU, low temperature radiators > Leaving water temperature range from 5°C to 45°C without electric heater > Super wide operating range for cold/hot water production from -20°C to +43°C ambient outdoor temperature > S aves time on system design as all water-side components are fully integrated with direct control over leaving water temperature > Saves space with contemporary wall hung design > Requires no gas connection or oil tank Liquid pipe Gas pipe Hot/cold water VRV indoor units Air handling unit VRV IV heat pump Low temp. radiator HXY-A8 Low temperature hydrobox Under floor heating Indoor unit Cooling capacity Heating capacity Casing Dimensions Weight Sound pressure level Operation range Refrigerant Refrigerant circuit Water circuit Power supply Recommended fuses Trade Unit Price Nom. Nom. Colour Material Unit Unit Nom. Heating kW kW Height x Width x Depth Ambient Water side Min.~Max. Min.~Max. Type Liquid Gas Piping connections diameter HXY080A8 HXY125A8 8.0 9.0 12.5 14.0 White Precoated sheet metal 890x480x344 44 -20~24 25~45 R-410A 3/8 (9.5) 5/8 (15.9) G 1”1/4 (female) 1 / 50 / 230 5 mm kg dBA °C °C inch (mm) inch (mm) inch Phase / Hz / V A £1,520.00 £2,132.00 Price List Update: Valid from 1st January 2017 63 HXHD-A8 / HXY-A8 Hot Water Generation – VRV Heat Recovery Systems VRV Producing hot water from a heat recovery VRV system is one of the most energy efficient means of providing hot water within a building. We can provide high and low temperature hot water for bathrooms, wash basins, underfloor heating, radiators and even provide heated water for air handling unit applications. HXHD-A8 (High temperature) Using waste heat to provide hot water means you can provide an additional service to your building from the heat recovery VRV system at very low cost. Features and benefits: For both low temperature and high temperature > Uses heat pump technology to produce hot water efficiently, providing up to 17% savings compared to a gas boiler > Saves time on system design as all water-side components are fully integrated with direct control over leaving water temperature > Requires no gas connection or oil tank HXY-A8 (Low temperature) For low temperature > Highly efficient space heating/cooling > Leaving water temperature range from 5°C to 45°C without electric heater > Super wide operating range for cold/hot water production from -20°C to +43°C ambient outdoor temperature > Saves space with contemporary wall hung design For high temperature > Possibility to connect thermal solar collectors to the domestic hot water tank > Leaving water temperature range from 25°C to 80°C without electric heater > Various control possibilities with weather dependant set point or thermostat control 45°C - 75°C Domestic hot water VRV indoor units VRV heat recovery with connection to heating only hydrobox (REYQ-T) EKHTSU-AC EKHWP-(P)B* 25°C - 75°C Air handling unit BS-Box 45°C - 75°C Low temp. radiator BS-Box Heating only hydrobox for VRV 25°C - 35°C Liquid pipe Gas pipe Discharge gas pipe Hot/cold water BS-Box Hot/cold water *PB for pressurised solar, B with drainback solar. 64 Residential, Commercial and Industrial HXY-A8 Low temperature hydrobox Under floor heating HXHD-A8 / HXY-A8 Hot Water Generation – VRV Heat Recovery Systems Indoor unit HXHD125A8 HXY080A8 High Temperature Dimensions Weight Sound pressure level Operation range Nom. Nom. Colour Material Unit Unit Nom. Night quiet mode Heating Domestic hot water Refrigerant Refrigerant circuit Water circuit Power supply Current kW kW 14.0 Metallic grey 8.0 9.0 12.5 14 White Precoated sheet metal Height x Width x Depth Level 1 Ambient Water side Ambient Water side Type Liquid Gas Piping connections diameter Heating water system Water volume Recommended fuses Trade Unit Price Min.~Max. Min.~Max. Min.~Max. Min.~Max. Min.~Max. mm kg dBA dBA °C °C °CDB °C inch (mm) inch (mm) inch l Phase / Hz / V A 705x600x695 92 42 (1) / 43 (2) 38 (1) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 3/8 (9.5) 1/2 (12.7) G 1” (female) 20~200 1 / 50 / 230 20 890x480x344 44 VRV Cooling Capacity Heating capacity Casing HXY125A8 Low Temperature -20~24 25~45 R-410A 3/8 (9.5) 5/8 (15.9) G 1” 1/4(female) 1 / 50 / 230 5 £2,822.00 £1,520.00 £2,132.00 (1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting Notes: i) Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 80-83) ii) Hydroboxes are inclusive of integral expansion vessel, and pump EKHTSU-AC HT Water Tank Domestic Unvented Hot Water Tank Energy Efficiency Class Standing Heat Loss Water Volume Max Water Temperature Height Width Depth Empty Weight Colour Material Inside Tank Material Outside Casing Piping Connections Water inlet H/E (Diameter) Water outlet H/E Cold Water in Hot water out Trade Unit Price UK.EKHTSU200AC W l °C mm mm mm kg mm mm inch inch UK.EKHTSU260AC Unvented System (Includes EKUHWHTB unvented Kit as shown below) B B 50 63 200 260 75 1335 1610 600 600 695 695 70 78 Metallic grey Stainless Steel Precoated sheet metal 25 (female quick coupling supplied) 25 (female quick coupling supplied) 3/4” (female) 3/4” (female) £1,158.00 £1,312.00 Accessories: Notes: Accessories For Unvented Systems Trade Unit Price EKUHWHTB Included with UK.EKHTSU*AC £289.00 EKFMAHTB Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve, Expansion Vessel, Tundish [G3 Safety Kit for compliance to Part G of section 3 of building regulations] Option for stand alone tank (ie not mounted on top of hydrobox) i) Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 80-83) ii) Hydroboxes are inclusive of integral expansion vessel and pump Price List Update: Valid from 1st January 2017 65 CYVS/M/L - DK - F/C/R In conjunction with Biddle, Daikin VRV IV heat recovery air curtain solutions combines the benefits of the Biddle air curtain technology with the benefits of Daikin VRV IV heat recovery. Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers. Easy and fast installation of these systems not only reduces costs but makes expensive water systems, boilers and gas connections redundant. Integrating a Biddle air curtain with Daikin VRV also eliminates the need to install multiple outdoor units thereby reducing installation time and costs further. This combination enables Daikin to offer its customers the ultimate environmentally conscious TOTAL SOLUTION PACKAGE comprising cooling, heating, outdoor-indoor climate separation and fresh air ventilation. Some air curtains may be ECA compliant please see ECA website for details www.daikin.co.uk/ECA Features and benefits: > > > > > > > > > Provides virtually free air curtain heating via recovered heat from indoor units in cooling mode Connection to the high COP heat recovery system enables COP’s of up to 4.36 Short payback times – less than 3 years Air curtain rectifier technology – deeply penetrating airstream Constant air velocity technology – all year round efficiency European patent 1.0, 1.5, 2.0 and 2.5 metre door widths Door heights of up to 3.7 metres Choice of colour RAL9010:White or RAL9006:Grey F = Free hanging model C = Cassette model R = Recessed model Biddle Comfort air curtain range Selection 3.7m 4m Maximum door height (m) VRV Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways. 3.2m 3m 2.8m 2.7m 3.1m 2.35m 2.0m 2.3m 2.5m 2m 2) W hen you know the size (S/M/L), refer to specific tables to select the model for your required door width 1m S M L S M L S M L Installation condition Ideal for doors in a shopping centre or revolving door entrance 66 1) U se the Door Height graph to determine the Air Curtain size relevant to your application For more exposed doors with some direct wind, suitable for ground floor applications Residential, Commercial and Industrial For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level CYVS/M/L - DK - F/C/R Biddle Standard Air Curtain – SMALL – Door Height 2.7m to 2m Maximum Door Width m Mounting Height *2 Max / Min 1.0 1.5 Model name Heating capacity speed 3 kW Delta T Inlet = room temperature speed 3 °K Power input (50Hz) Fan only / Heating kW Dimensions Height mm Width mm Depth mm kg Casing Colour Minimum requiring ceiling void *=F *=C 270 1,000 590 7.40 15 0.23/0.23 270 1,000 821 56 59 *=R CYVS150DK80*BC *=F *=C 270 1,048 561 270 1,500 590 9.00 15 0.35/0.35 270 1,500 821 61 66 83 CYVS200DK100*BC *=R *=F *=C 270 1,548 561 270 2,000 590 11.60 15 0.46/0.46 270 2,000 821 88 83 102 *=R CYVS250DK140*BC *=F *=C *=R 270 2,048 561 270 2,500 590 16.20 16 0.58/0.58 270 2,500 821 270 2,548 561 108 107 129 137 white RAL9010 mm Fan - Air flow rate Heating speed 3 m3/sec Sound pressure Refrigerant Heating Type speed 3 dBA Piping connections Liquid (OD) / Gas Power supply 2.5 2.7 / 2.0 CYVS100DK80*BC Type Weight 2.0 m 420 420 420 420 0.323 0.485 0.647 0.808 47 49 50 51 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 3/4 (19) R-410A inch (mm) Phase / Hz / V 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 £2,586.00 £2,555.00 £2,663.00 £3,294.00 £3,262.00 £3,444.00 £3,981.00 £3,950.00 £4,268.00 £4,441.00 £4,410.00 £4,758.00 Trade Unit Price M Biddle Standard Air Curtain – MEDIUM – Door Height 3.2m to 2.3m Maximum Door Width m Mounting Height *2 Max / Min 1.0 Model name *=F Heating capacity speed 3 kW Delta T Inlet = room temperature speed 3 °K Power input (50Hz) Fan only / Heating kW Height Width Depth Weight Casing Colour Minimum requiring ceiling void mm mm mm kg Heating speed 3 m3/sec Sound pressure Refrigerant Heating Type speed 3 dBA Piping connections Liquid (OD) / Gas Power supply 2.5 *= R CYVM150DK80*BC *=F *=C CYVM200DK100*BC *=R *=F *=C *=R CYVM250DK140*BC *=F *=C 9.20 11.00 13.40 19.90 17 0.37/0.37 14 0.56/0.56 13 0.75/0.75 15 0.94/0.94 270 1,000 821 270 1,048 561 270 1,500 590 270 1,500 821 57 68 66 73 88 270 1,548 561 270 2,000 590 93 94 white RAL9010 *=R 270 2,000 821 270 2,048 561 270 2,500 590 270 2,500 821 270 2,548 561 111 117 108 136 144 420 420 420 420 0.446 0.669 0.892 1.115 50 51 53 54 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 3/4 (19) R-410A inch (mm) Phase / Hz / V 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9) 1 / 50 / 230 £2,958.00 £2,926.00 £3,036.00 £3,790.00 £3,758.00 £3,924.00 £4,695.00 £4,664.00 £4,980.00 £5,343.00 £5,313.00 £5,654.00 Trade Unit Price L *=C 270 1,000 590 mm Fan - Air flow rate 2.0 3.2 / 2.3 CYVM100DK80*BC Type Dimensions 1.5 m Biddle Standard Air Curtain – LARGE – Door Height 3.7m to 2.5m Maximum Door Width m Mounting Height *2 Max / Min 1.0 1.5 Model name speed 3 kW speed 3 °K kW mm mm mm kg mm speed 3 m3/sec speed 3 dBA 2.5 3.7 / 2.5 CYVL100DK125*BC Type Heating Capacity Delta T Inlet = room temperature Power Input (50Hz) Fan only / Heating Dimensions Height Width Depth Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply 2.0 m *=F *=C 370 1,000 774 76 15.6 15 0.75 / 0.75 370 1,000 1105 81 *=R 370 1,048 745 83 CYVL150DK200*BC *=F *=C 370 1,500 774 100 23.3 15 1.13 / 1.13 370 1,500 1105 118 CYVL200DK250*BC *=R *=F 370 370 1,548 2,000 745 774 141 126 white RAL9010 520 0.861 53 520 1.292 54 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 3/4 (19) *=C 29.4 14 1.50 / 1.50 370 2,000 1105 151 *=R 370 2,048 745 155 CYVL250DK250*BC *=F *=C *=R 370 2,500 774 157 31.1 12 1.88 / 1.88 370 2,500 1105 190 370 2,548 745 196 520 1.722 56 520 2.153 57 3/8 (9.5) / 7/8 (22.2) 3/8 (9.5) / 7/8 (22.2) R-410A inch (mm) Phase / Hz / V 1 / 50 / 230 £3,768.00 £3,729.00 £3,844.00 £5,013.00 £4,975.00 £5,130.00 £6,173.00 £6,133.00 £6,441.00 £7,168.00 £7,130.00 £7,508.00 Trade Unit Price Accessories: Notes: Accessory Ref Description Trade Price BRC1E53A KRCS01-1 RTD-20/UK.FB2 Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock Remote room mounted temperature sensor Energy control PCB for Sky Air and VRV £79.00 £48.00 £262.00 *2: Mounting Height at base of door curtain air outlet F = Free Hanging / C = Cassette / R = Recessed i) Biddle Remote Controller and connection cable included for Fan Speed Control ii) If RTD-20 Connected in Air Curtain mode the Biddle Remote Controller is NOT connected as Fan speed is managed by RTD-20 iii) Code “BC” is for white finish. Aluminium finish “SC”available on request Price List Update: Valid from 1st January 2017 67 VRV S The VRV Total Solution VRV Many buildings today typically operate quite separate systems for heating, cooling, refrigeration and hot water. As a result, a huge amount of energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution for heating, cooling, refrigeration and ventilation. The VRV total solution Air conditioning, refrigeration and cooling IT servers can generate waste heat that can be reused to heat and ventilate other areas of the building or to provide hot water for wash rooms, at a much reduced cost. By understanding the whole building’s heating and cooling needs at the outset, an integrated climate control solution can be delivered that offers much higher energy efficiency levels, thus reducing the carbon impact of a building. This means that all internal and external conditions must be taken into account in the design of the climate control system. NEW Extended piping range > Increased efficiency and versatility. > V RV IV Heat Recovery systems have received an upgraded piping capability which allows fan coils to be spread over 10 floors on the same system. > N ow it is possible to have up to 30m height separation between indoor units, allowing even more versatility than ever before and allowing heat recovery between more floors. Piping Rules Maximum pipe length from Condenser to furthest indoor unit Maximum distance from 1st Refnet joint to furthest fan coil Maximum total pipework length (VRV Fan coils) Maximum difference from indoor unit to its own refnet Maximum Height difference between Outdoor and Indoor Maximum Height difference between indoor units Heat Recovery Heat Pump Mini Compact Mini Standard Mini Extended VRVQ VRV-W 8-54 hp 8-54 hp 4, 5 hp 4, 5, 6 hp 8, 10, 12 hp 8-48 hp 8-30 hp 165m 165m 70m 120m 100m 120m 120m 90m 90m 40m 40m 40m 40m 90m* 1000m 1000m 300m 300m 300m 300m 300m 40m 40m 40m 40m 40m 40m 40m 90m 90m 30m 40-50m* 40-50m* 40-50m* 40-50m* 30m 30m 15m 15m 15m 15m 15m Note: * 40m if condenser is below indoors - 50m if condenser above indoors Not all limitations are shown for every combination of indoor units Some limitations cannot be used together on the same system Some limitations require approval Please contact Daikin UK for more details on pipework design 68 Residential, Commercial and Industrial VRV VRV Services Strip Down and Rebuild Our Strip and Rebuild Service offers you the benefit of time and cost savings, as it means that you can have VRV outdoor units delivered to site in portable components, so they can be transported to the roof without the need for cranes or applying for road closure permissions. PRICE ON APPLICATION Lead time: 3 weeks Applicable condensers: VRV, CVP, Zeas How it works: > Our engineers will strip down and package the components securely in a purpose built container at our workshop > W e then organise delivery to the kerb-side on site where the contractor can unload, lift and manoeuvre the units into place > O ur engineers will then attend site to rebuild, pressure test, and vacuum and charge the unit with refrigerant ready for connection to the rest of the system > If the unit is to be kept on site for any period of time, please ensure the container is kept dry and is not opened. When asking for a quotation or ordering, please state the unit you require and also that you require the strip and rebuild service. Painted Units Customers sometimes require visible units to be less obtrusive, whether for aesthetic or planning reasons. Daikin UK offer a customised service where we can repaint our units to any specified RAL or BS finish. Our repainting service is done in house in our purpose built facility and includes removing base paint to give a uniform, long lasting and professional finish. We have repainted fan coils, decoration panels, BS boxes and all types of condensers for a number of clients. PRICE ON APPLICATION Lead time: 2-3 weeks Applicable units: All When asking for a quotation or ordering, please state the unit you require along with the finish requirements e.g. colour, pattern etc. Please note: The stated lead times are a guide, this can be influenced by the design and complexity of the requirement. Price List Update: Valid from 1st January 2017 69 VRV IV S Series – New Extended Range Now with: VRV Low Height compact 4 & 5 hp 1 Phase > V ariable Refrigerant Temperature > AHU connection > Air curtain connection Standard 4, 5 & 6 hp 1 Phase and 3 Phase 823mm 1615mm Large Capacity 8, 10 & 12 hp 3 Phase 10/12 hp 70 Residential, Commercial and Industrial 8 hp 4/5/6 hp 4/5 hp VRV IV S-series – RXYSCQ-T VRV IV Condensing Unit – Low Height Compact Mini VRV Outdoor Units Power Input 50Hz Nominal Cooling Nominal Heating Cooling (Nom) Heating (Nom) EER (at Nom Capacity) COP (at Nom Capacity) Dimensions Height x Width x Depth Weight Refrigerant Circuit Refrigerant Type Sound Pressure (Nom) Cooling Sound Power (Nom) Cooling Maximum No of Connectable Units Electrical Details Power Supply Running Current Starting Current Fuse Rating Piping Limits Total Piping length Maximum Length Maximum Vertical Rise Piping Connections Liquid Gas Capacity Index Limit RXYSCQ4TV1 RXYSCQ5TV1 12.1 12.1 3.43 3.18 3.53 3.81 14.0 14.0 4.26 3.19 3.29 3.58 kW kW kW kW mm kg 823 x 940 x 460 94 VRV Capacity 94 R410A dBA dBA 51 68 8 Phase / Hz / V amps amps amps m m m inch (mm) inch (mm) Trade Condensing Unit Price 52 69 10 1 / 50 / 230 19.0 4 32 300 70 (90 equivalent) 30 3/8 (9.5) 5/8 (15.9) 50~130 3/8 (9.5) 5/8 (15.9) 62.5~162.5 £2,561.00 £2,878.00 823mm high Less than 1m > New low height Mini VRV, making complying with planning restrictions in towns and cities easier > Compact – only 823mm high > Lightweight – for simple installation > Variable Refrigerant temperature – enhanced efficiency > In addition to VRV fan coils, low height Mini VRV is connectable to: Stylish indoor units – Emura and Nexura – as well as Air Handling Units and Biddle Air Curtains > Single phase Parapet wall Features: Roof Planning issues for small commercial or residential projects in towns and cities can now be easy to overcome with a Low height version of the mini VRV range, available in 4 & 5hp with Variable Refrigerant Temperature. Connectable to products such as Air Curtains, Air Handling Units and the Emura and Nexura fan coils, the Low height Mini VRV range brings a whole new level of versatility to the VRV range. Daikin VRV IV S-series units can be installed discreetly on a balcony thanks to their compact dimensions, offering you air conditioning while being almost unnoticeable. Price List Update: Valid from 1st January 2017 71 VRV IV S-series – RXYSQ-T VRV IV Condensing Units – Standard Mini VRV Outdoor Units VRV Capacity EER (Nom Capacity) COP (Nom Capacity) Dimensions Weight Air Flow Rate Electrical Details Nominal Cooling Nominal Heating kW kW Height x Width x Depth mm kg m3/sec Phase / Hz / V amps amps amps Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Circuit Sound Pressure (Nom) Sound Power (Nom) Piping Limits Piping Connections Maximum Length Liquid Gas RXYSQ4TV1 RXYSQ5TV1 RXYSQ6TV1 RXYSQ4TY1 RXYSQ5TY1 RXYSQ6TY1 12.1 12.1 4.00 4.52 14.0 14.0 3.75 4.28 15.5 15.5 3.40 3.90 12.1 12.1 4.00 4.52 14.0 14.0 3.75 4.28 15.5 15.5 3.40 3.90 4.44 3 / 50 / 380~415 5.55 6.84 1345 x 900 x 320 104 1.767 14.0 1 / 50 / 230 17.3 21.2 4 32 16 R410A dBA dBA m inch (mm) inch (mm) 50 68 51 69 51 70 50 68 51 69 51 70 300 3/8 (9.5) Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 50 - 130 8 5/8 (15.9) 62.5 - 162.5 10 3/4 (19) 70 -182 12 5/8 (15.9) 50 - 130 8 5/8 (15.9) 62.5 - 162.5 10 3/4 (19) 70 -182 12 Trade Condensing Unit Price £2,845.00 £3,197.00 £3,569.00 £2,900.00 £3,287.00 £3,651.00 Technologies Refrigerant-cooled PCB > Reliable cooling because it is not influenced by ambient air temperature > Smaller switchbox for smoother air flow through the heat exchanger increasing heat exchange efficiency with 5% Features Super aero grille The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise. Improved fan blades Old New Vane fixed to rotor Rotor Separate Collision Compressor Air streams collide and generate loss Swing type > no oil separator Vane & rotor are unified resulting in: > Reduced noise level > Longer compressor life > Higher efficiency Air streams are smoothed around V-cut and reduces air flow loss E-Pass heat exchanger Optimising the heat exchanger’s path layout prevents heat being transferred from the overheated gas section to the sub-cooled liquid section which is a more efficient way to use the heat exchanger. Standard heat exchanger I-demand function Limit maximum power consumption. The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption. Power consumption e-Pass heat exchanger Predefined limit In 85 °C In 85 °C 43 °C 55 °C 27 °C 72 55 °C 27 °C 60 °C 50 °C 55 °C Out 45 °C Out 45 °C Residential, Commercial and Industrial Time VRV S-series – RXYSQ-T VRV IV Condensing Unit – High Capacity Mini VRV EER COP Dimensions Weight Air Flow Rate Electrical Details Refrigerant Circuit Sound Pressure (Nom) Sound Power (Nom) Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height x Width x Depth mm kg m3/sec Phase / Hz / V amps amps amps Power Supply Running Current Starting Current Fuse Rating Refrigerant Type RXYSQ8TY1 RXYSQ10TY1 RXYSQ12TY1 22.4 22.4 3.66 4.31 1430x940x320 144 2.333 28.0 28.0 3.4 4.24 33.5 33.5 3.3 4.09 1615x940x460 175 180 3.033 3 / 50 / 380~415 10.7 4 9.6 13.4 25 32 Capacity Index Limit Maximum Number of Connected Indoor Units 3/8 (9.5) 3/4 (19) 100 - 260 17 R410A 55 74 300 3/8 (9.5) 7/8 (22.2) 125 - 325 21 1/2 (12.7) 1 1/8 (28.6) 150 - 390 26 Trade Condensing Unit Price £4,542.00 £4,963.00 £6,077.00 Maximum Length Liquid Gas dBA dBA m inch (mm) inch (mm) 55 73 VRV Outdoor Units Capacity 57 76 Features: > High capacity up to 33.5kW nominal cooling > Horizontal blow casing > Variable Refrigerant Temperature > Connection to stylish split fan coils > Compact installation – reduction in floor space > Available in 8, 10 & 12 hp Planning requirements in built up areas require increasingly more innovative products to overcome restrictions, especially on visibility of plant. By having a smaller footprint and weight than its big brother, the extended high capacity Mini VRV range is easier to hide and can help to maximise the lettable floor area on a design. Mini VRV systems deliver VRV performance in a small, convenient package by offering a compact, horizontal blow, air conditioning solution for projects with lower capacity requirements or where discretion is required due to the planning or aesthetic requirements of the application. Daikin are pleased to announce that Mini VRV systems have received a complete redesign, and with this extension to the range which includes new features to increase performance, convenience and flexibility, Mini VRV from Daikin will become an even more popular choice for residential and smaller capacity Air conditioning applications. 10/12 hp 8 hp Price List Update: Valid from 1st January 2017 73 VRV IV i-series – SB.RKXYQ-T VRV IV Condensing Unit – For Indoor Installation VRV The VRV IV i-series is a truly unique solution for installations where you want a completely invisible solution. The system is installed entirely indoors and only the grilles are visible. So it’s ideal for urban environments, where space and planning restrictions are especially challenging. A cost effective solution Even when it is possible to install an outdoor unit, there are reasons that an indoor installation offers a better solution, such as in areas where there is a mixture of commercial and residential use. With the VRV IV i-series, the units are effectively invisible because they are installed indoors. Thanks to their low operating sound, they are highly suited to densely populated areas such as city centres – and dedicated modes reduce sound further to comply with inner-city noise regulations, so there is no need for costly sound insulation. The VRV IV i-series offers: > A unique VRV indoor solution: the ‘outdoor’ air conditioning unit can now be fitted indoors > Connection with up to 10 indoor units > Seamless integration into surrounding architecture > Total flexibility for any shop location and building type > E asy compliance with planning regulations, the best solution for urban locations > A total solution when combined with ventilation units and Biddle air curtains Nor is there ay need to use a crane for installation on the roof or back of the property as the unit comes in two parts, making the VRV IV i-series easier and more cost effective to install. RDXYQ-T RKXYQ-T i Total Piping length possibilities RKXYQ5 (a) =HM <> CM (b) = CM <> IU (c) = (a) + (b) 5 10 15 20 25 30 135 125 115 105 95 85 140 135 130 125 120 115 HM: Heat Exchanger Module CM: Compressor Module 74 Residential, Commercial and Industrial VRV IV i-series – SB.RKXYQ-T VRV IV Condensing Unit – for indoor installation Unique split unit for indoor installation Compact and easy to hide, the compressor can be installed at floor level, in a back office, storage room, technical area or in a kitchen, while the heat exchanger can be installed in a false ceiling space. This means that the air conditioning system is completely invisible and does not take up expensive commercial floor space. Installation flexibility > Unrivalled flexibility because the unit is split into two elements: the heat exchanger and the compressor > Lightweight units reduce installation time and effort, making it easy for just two people to transport and install > Shorter pipe runs between the indoor units reduces installation costs > V ariable Refrigerant Temperature for best seasonal efficiency & comfort > Patented V-shape heat exchanger for the most compact unit (400 mm high) > Super-efficient centrifugal fans (85% more efficient than equivalent sirocco fan) > Inverter fan can be easily adjusted to the length of ductwork > Optimised shape for higher air flow and static pressure, resulting in much higher efficiencies when compared to standard outdoor units installed indoors Compact compressor unit > Small footprint maximizing usable floor space (600 x 554 mm) > Can easily be mounted in a storage room or back office > Rotating switchbox for easy maintenance > Easy serviceability, all components can be easily reached Outdoor system SB.RKXYQ Capacity range Cooling capacity (nom) Heating capacity (nom) / Heating capacity (max) EER (nom) COP (nom/max) Maximum number of connectable indoor units Indoor index connection Min. / Nom. / Max. Operation range - outdoor air temperature Cooling Heating Temperature around casing Refrigerant Type / GWP Piping connections between Liquid compressor module (CM) Gas and heat exchanger module (HM) Maximum length Max height difference - CM below HM Max height difference - CM above HM Piping connections between compressor Liquid module (CM) and indoor units (IU) Gas Max total piping length (incl. piping to HM) Max length to last IU Max height difference - CM below IU Max height difference - CM above IU Max height difference - IU - IU Nom. HP kW Min.~Max. Min.~Max. °CDB °CWB OD OD kg / TCO2 inch (mm) inch (mm) m m m Heat exchanger module Weight Ducting Sound pressure level (Cooling) Sound Power level (Cooling) Drain pipe Power supply Current 50 Hz RDXYQ Height x Width x Depth Suction size Discharge size Max ESP Nom. air flow Nom / Low sound Nom OD Phase / Frequence / Voltage Maximum Fuse Amps (MFA) mm kg mm mm Pa m³/sec dBa dBa mm Trading Condensing Unit Price Compressor module Dimensions Weight Refrigerant charge Sound pressure level Power supply Power supply Current 50 Hz Trading Condensing Unit Price RKXYQ Height x Width x Depth Phase / Frequence / Voltage Phase / Frequence / Voltage Maximum Fuse Amps (MFA) Nominal running current (RLA) 8T 5 14.0 14.0/16.0 3.2 3.80/3.40 10 62.5 / 125 / 162.5 8 21.4 21.4 / 25.0 2.8 3.60/3.29 17 100 / 200 / 260 -5.0 ~ 46.0 -20.0 ~ 15.5 5.0 ~ 35.0 R-410A / 2087.5 1/2 (12.7) 3/4 (19.1) 30 10 10 3/8 (9.5) 5/8 (15.9) 140 1/2 (12.7) 7/8 (22.2) 30 10 10 3/8 (9.5) 3/4 (19.1) 300 70 (90 equivalent) Trading Condensing Unit Price Dimensions 5T mm kg kg dBa 30 30 15 30 30 15 £4,756.00 £6,930.00 5T 8T 397 x 1456 x 1044 397 x 1456 x 1044 97 1200 x 300 1200 x 300 60 / 150 0.917 47 76 32 (VP25) 1~ / 50 Hz / 220-240V 10 103 1200 x 300 1200 x 300 60 / 150 1.667 55 / 48 81 32 (VP25) 1~ / 50 Hz / 220-240V 10 £2,045.00 £2,980.00 5T 8T 701 x 600 x 554 77 2.0 47 60 3~ / 50 Hz / 380-415V 16 5.8 701 x 760 x 554 105 4.0 48 64 3~ / 50 Hz / 380-415V 20 8.6 £2,711.00 £3,950.00 Price List Update: Valid from 1st January 2017 75 VRV Superior efficiencies RYYQ-T Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P Heat Pump VRV IV VRV 3 revolutionary features: Variable Refrigerant Temperature Customise your VRV for best Seasonal Efficiency and comfort: evolutionary variable refrigerant temperature control > R automatically adapts the system to individual building and climate requirements for greater efficiency and comfort ontinuously adjusts refrigerant temperature to the actual > C temperature and capacity required efault mode optimised by Daikin for UK conditions with > D maximum efficiency and comfort > Delivers annual cost savings of up to 28% VRV configurator Continuous heating during defrost Advanced software for simplified commissioning, servicing, configuration and customisation: The new standard in heating comfort: > S implified commissioning: graphical interface to configure, commission and upload system settings > U nique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems > Delivers uninterrupted heat, even during the defrost cycle > S implified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out > Maintains comfortable indoor climate at all times > Manage systems over multiple sites RYYQ-T (up to 20 hp) VRV IV Heat Pump with Continuous Heating Outdoor Units RYYQ8T8 RYYQ10T RYYQ12T RYYQ14T RYYQ16T RYYQ18T RYYQ20T 22.40 25.00 4.30 7.53* 4.54 1685 x 930 x 765 261 2.700 78 28.00 31.50 3.84 7.2* 4.27 1685 x 930 x 765 268 2.917 78 33.50 37.50 3.73 6.96* 4.12 1685 x 930 x 765 268 3.083 78 45.00 50.00 3.46 6.5* 3.91 1685 x 1240 x 765 364 4.333 78 50.00 56.00 3.40 6.38* 3.89 1685 x 1240 x 765 398 4.183 78 56.00 63.00 3.03 5.67* 3.71 1685 x 1240 x 765 398 4.350 78 8.4 11.5 14.2 20.6 23.4 29.5 20 25 32 40 40 50 5.9 6.0 6.3 10.4 11.7 11.8 58 78 165 58 79 165 61 81 165 64 86 165 65 86 165 66 88 165 Capacity Index Limit Maximum Number of Connected Indoor Units 3/8 (9.5) 3/4 (19.1) 100~260 64 3/8 (9.5) 7/8 (22.2) 125~325 64 1/2 (12.7) 1 1/8 (28.6) 150~390 64 40.00 45.00 3.64 6.83* 4.02 1685 x 1240 x 765 364 3.717 78 3 / 50 / 380~415 17.2 4 32 R410A 10.3 data book 61 81 165 data book 1/2 (12.7) 1 1/8 (28.6) 175~455 64 1/2 (12.7) 1 1/8 (28.6) 200~520 64 5/8 (15.9) 1 1/8 (28.6) 225~585 64 5/8 (15.9) 1 1/8 (28.6) 250~650 64 Trade Condensing Unit Price £4,724.00 £5,162.00 £6,321.00 £7,374.00 £8,511.00 £9,481.00 £10,430.00 Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height x Width x Depth mm High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas kg m3/sec Pa Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). 76 Residential, Commercial and Industrial RYYQ-T (22 to 24 hp) VRV IV Heat Pump with Continuous Heating RYYQ22T RYYQ24T RYMQ10T Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height x Width x Depth mm kg m3/sec Pa Phase / Hz / V amps amps amps High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas RYMQ12T RYMQ8T RYMQ16T 61.50 69.00 3.77 7.07* 4.18 67.40 75.00 3.70 6.81* 4.10 1685 x 930 x 765 195 2.917 78 1685 x 930 x 765 1685 x 930 x 765 195 188 3.083 2.700 78 78 3 / 50 / 380~415 14.2 8.4 4 32 20 R410A 6.3 5.9 databook 61 58 81 78 11.5 25 kg kg dBA dBA m m inch (mm) inch (mm) 6.0 58 79 1685 x 1240 x 765 309 4.333 78 VRV Outdoor Units 20.6 40 10.4 64 86 165 165 databook Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 1 1/8 (28.6) 275~715 64 5/8 (15.9) 1 3/8 (34.9) 300~780 64 Trade Condensing Unit Price £11,483.00 £13,235.00 * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). RYYQ-T (26 to 34 hp) VRV IV Heat Pump with Continuous Heating Outdoor Units RYYQ26T RYYQ28T RYYQ30T RYYQ32T RYYQ34T RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T Capacity EER ESEER COP Dimensions Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps 73.50 82.50 3.68 6.89* 4.06 78.50 87.50 3.57 6.69* 4.00 83.50 93.50 3.52 6.6* 3.98 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 3/8 (34.9) 325~845 64 3/4 (19.1) 1 3/8 (34.9) 350~910 64 1685 1685 930 1240 765 765 195 319 3.083 4.183 78 78 3 / 50 / 380~415 14.2 23.4 4 32 40 R410A 6.3 11.7 data book 61 65 81 86 165 data book 3/4 (19.1) 1 3/8 (34.9) 375~975 64 Trade Condensing Unit Price £13,695.00 £14,832.00 £15,802.00 Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) 1685 930 765 195 3.083 78 1685 1240 765 309 3.717 78 1685 930 765 195 3.083 78 1685 1240 765 309 4.333 78 14.2 17.2 14.2 20.6 32 32 32 40 6.3 10.3 6.3 10.4 61 81 61 81 61 81 64 86 90.00 100.00 3.46 6.5* 3.91 95.00 106.00 3.43 6.44* 3.90 1685 1240 765 309 4.333 78 1685 1240 765 309 4.333 78 1685 1240 765 309 4.333 78 1685 1240 765 319 4.183 78 20.6 20.6 20.6 23.4 40 40 40 40 10.4 10.4 10.4 11.7 64 86 64 86 64 86 65 86 3/4 (19.1) 1 3/8 (34.9) 400~1040 64 3/4 (19.1) 1 3/8 (34.9) 425~1105 64 £17,022.00 £17,992.00 * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Price List Update: Valid from 1st January 2017 77 RYYQ-T (36 to 42 hp) VRV IV Heat Pump with Continuous Heating Outdoor Units RYYQ36T RYYQ38T RYYQ40T RYYQ42T RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T VRV Capacity EER ESEER COP Dimensions Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps 101.00 113.00 3.21 6.02* 3.79 1685 1685 1240 1240 765 765 309 319 4.333 4.350 78 78 1685 930 765 188 2.700 78 106.00 120.00 3.42 6.36* 4.01 1685 930 765 195 2.917 78 1685 1240 765 319 4.350 78 112.00 125.00 3.61 6.74* 4.05 1685 930 765 195 3.083 78 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 5/8 (41.3) 450~1170 64 3/4 (19.1) 1 5/8 (41.3) 475~1235 64 1685 930 765 195 2.917 78 3 / 50 / 380~415 11.5 14.2 4 25 32 R410A 6.0 6.3 data book 58 61 79 81 165 data book 3/4 (19.1) 1 5/8 (41.3) 500~1300 64 Trade Condensing Unit Price £18,941.00 £20,316.00 £20,964.00 Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) 20.6 29.5 8.4 11.5 29.5 40 50 20 25 50 10.4 11.8 5.9 6.0 11.8 64 86 66 88 58 78 58 79 66 88 1685 1240 765 319 4.183 78 1685 930 765 195 2.917 78 118.00 132.00 3.54 6.65* 4.00 1685 1240 765 309 4.333 78 23.4 11.5 20.6 20.6 40 25 40 40 11.7 6.0 10.4 10.4 65 86 58 79 64 86 64 86 1685 1240 765 309 4.333 78 3/4 (19.1) 1 5/8 (41.3) 525~1365 64 £22,184.00 * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). RYYQ-T (44 to 48 hp) VRV IV Heat Pump with Continuous Heating Outdoor Units Capacity RYYQ44T 1685 930 765 195 3.083 78 124.00 138.00 3.54 6.62* 3.98 1685 1240 765 309 4.333 78 1685 1240 765 309 4.333 78 1685 1240 765 309 3.717 78 14.2 20.6 20.6 17.2 32 40 40 32 6.3 10.4 10.4 10.3 61 81 64 86 64 86 61 81 RYMQ16T Trade Condensing Unit Price £23,343.00 £24,396.00 Sound Pressure Sound Power Piping Limits Piping Connections mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps RYMQ14T Capacity Index Limit Maximum Number of Connected Indoor Units Refrigerant Circuit Height Width Depth RYMQ16T 3/4 (19.1) 1 5/8 (41.3) 550~1430 64 Weight Air Flow Rate External Static Pressure Electrical Details kW kW RYMQ16T 130.00 145.00 3.51 6.6* 3.94 1685 1240 765 309 4.333 78 3 / 50 / 380~415 20.6 4 40 R410A 10.4 data book 64 86 165 data book 3/4 (19.1) 1 5/8 (41.3) 575~1495 64 EER ESEER COP Dimensions Nominal Cooling Nominal Heating RYYQ46T RYMQ12T High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) RYYQ48T RYMQ16T RYMQ16T RYMQ16T RYMQ16T 1685 1240 765 309 4.333 78 1685 1240 765 309 4.333 78 135.00 150.00 3.46 6.5* 3.91 1685 1240 765 309 4.333 78 1685 1240 765 309 4.333 78 20.6 20.6 20.6 20.6 40 40 40 40 10.4 10.4 10.4 10.4 64 86 64 86 64 86 64 86 3/4 (19.1) 1 5/8 (41.3) 600~1560 64 £25,533.00 * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). 78 Residential, Commercial and Industrial RYYQ-T (50 to 54 hp) VRV IV Heat Pump with Continuous Heating Capacity RYYQ50T RYYQ52T RYMQ16T RYMQ16T RYMQ18T RYMQ16T 1685 1240 765 319 4.183 78 1685 1240 765 309 4.333 78 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 5/8 (41.3) 625~1625 64 145.00 162.00 3.42 6.42* 3.89 1685 1240 765 319 4.183 78 3 / 50 / 380~415 23.4 4 40 R410A 11.7 data book 65 86 165 data book 3/4 (19.1) 1 5/8 (41.3) 650~1690 64 Trade Condensing Unit Price £26,503.00 £27,473.00 EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps 1685 1240 765 309 4.333 78 140.00 156.00 3.44 6.46* 3.90 1685 1240 765 309 4.333 78 20.6 20.6 23.4 20.6 40 40 40 40 kg kg dBA dBA m m inch (mm) inch (mm) 10.4 10.4 11.7 10.4 64 86 64 86 65 86 64 86 RYMQ18T High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas RYYQ54T RYMQ18T RYMQ18T RYMQ18T RYMQ18T 1685 1240 765 319 4.183 78 1685 1240 765 319 4.183 78 150.00 168.00 3.40 6.38* 3.89 1685 1240 765 319 4.183 78 1685 1240 765 319 4.183 78 23.4 23.4 23.4 23.4 40 40 40 40 11.7 11.7 11.7 11.7 65 86 65 86 65 86 65 86 VRV Outdoor Units 3/4 (19.1) 1 5/8 (41.3) 675~1755 64 £28,443.00 * The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Price List Update: Valid from 1st January 2017 79 REYQ-T (8 to 12 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 8 hp Single 10 hp Single REYQ8T REYQ10T 22.40 22.40 1685 x 930 x 765 210 2.700 28.00 28.00 1685 x 930 x 765 218 2.917 8.9 11.8 20 25 9.7 9.8 58 78 58 79 Capacity Index Limit Maximum Number of Connected Indoor Units 3/8 (9.5) 5/8 (15.9) 3/4 (19.1) 100 ~ 260 64 3/8 (9.5) 3/4 (19.1) 7/8 (22.2) 125 ~ 325 64 3/8 (9.5) 3/4 (19.1) 7/8 (22.2) 125 ~ 325 64 1/2 (12.7) 3/4 (19.1) 1 1/8 (28.6) 150 ~ 390 64 Trade Condensing Unit Price £5,184.00 £5,694.00 £7,114.00 £6,905.00 VRV Capacity Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) 10 hp Multi REMQ5T 12 hp Single REMQ5T REYQ12T 1685 x 930 x 765 198 2.700 33.50 33.50 1685 x 930 x 765 218 3.084 5.3 15.3 20 25 9.7 9.9 58 78 61 81 28.00 28.00 1685 x 930 x 765 198 2.700 3 / 50 / 380~415 5.3 4 20 R410A 9.7 data book 58 78 1000 165 REYQ-T (13 to 16 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 13 hp Multi REYQ8T Capacity Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price 80 Residential, Commercial and Industrial REMQ5T 36.40 33.50 1685 x 930 x 765 1685 x 930 x 765 210 210 2.700 2.700 8.9 5.3 20 20 9.7 9.7 58 78 58 78 1/2 (12.7) 3/4 (19.1) 1 1/8 (28.6) 162.5 ~ 422.5 64 £8,741.00 14 hp Single 16 hp Single REYQ14T REYQ16T 40.00 45.00 40.00 45.00 1685 x 1240 x 765 1685 x 1240 x 765 304 305 3.717 4.334 3 / 50 / 380~415 17.4 21.1 4 32 40 R410A 11.8 11.8 data book 61 64 81 86 1000 165 1/2 (12.7) 1/2 (12.7) 7/8 (22.2) 7/8 (22.2) 1 1/8 (28.6) 1 1/8 (28.6) 175 ~ 455 200 ~ 520 64 64 £8,141.00 £9,593.00 16 hp Multi REYQ8T REYQ8T 45.00 45.00 1685 x 930 x 765 1685 x 930 x 765 210 210 2.700 2.700 8.9 8.9 20 20 9.7 9.7 58 78 58 78 1/2 (12.7) 7/8 (22.2) 1 1/8 (28.6) 200 ~ 520 64 £10,368.00 REYQ-T (18 to 20 hp) VRV IV Condensing Units – Heat Recovery 18 hp Single 18 hp Multi REYQ18T Capacity Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) REYQ8T 50.40 50.40 1685 x 1240 x 765 337 4.184 40 11.8 65 86 Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price £10,665.00 20 hp Multi REYQ20T REYQ10T 51.00 56.00 51.00 56.00 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 210 218 337 2.700 2.917 4.350 3 / 50 / 380~415 8.9 11.8 31.1 4 20 25 50 R410A 9.7 9.8 11.8 data book 58 58 66 78 79 88 1000 165 5/8 (15.9) 5/8 (15.9) 7/8 (22.2) 1 1/8 (28.6) 1 1/8 (28.6) 1 1/8 (28.6) 225 ~ 585 250 ~ 650 64 64 24.6 5/8 (15.9) 7/8 (22.2) 1 1/8 (28.6) 225 ~ 585 64 20 hp Single REYQ10T £10,878.00 REYQ10T 56.00 56.00 1685 x 930 x 765 1685 x 930 x 765 218 218 2.917 2.917 11.8 11.8 25 25 9.8 9.8 58 79 58 79 £11,851.00 VRV Outdoor Units 5/8 (15.9) 1 1/8 (28.6) 1 1/8 (28.6) 250 ~ 650 64 £11,388.00 REYQ-T (22 to 28 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 22 hp Multi REYQ10T Capacity Dimensions Weight Air Flow Rate Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) 24 hp Multi REYQ12T 61.50 61.50 1685 x 930 1685 x 930 x 765 x 765 218 218 2.917 3.084 11.8 15.3 25 25 9.8 9.9 58 79 61 81 Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 1 1/8 (28.6) 1 1/8 (28.6) 275 ~ 715 64 Trade Condensing Unit Price £12,599.00 REYQ8T REYQ16T 26 hp Multi REYQ12T REYQ14T 67.40 73.50 67.40 73.50 1685 x 930 1685 x 1240 1685 x 930 1685 x 1240 x 765 x 765 x 765 x 765 210 305 218 304 2.700 4.334 3.084 3.717 3 / 50 / 380~415 8 21.1 15.3 17.4 4 20 40 25 32 R410A 9.7 11.8 9.9 11.8 data book 58 64 61 61 78 86 81 81 1000 165 5/8 (15.9) 3/4 (19) 1 1/8 (28.6) 1 1/8 (28.6) 1 3/8 (34.9) 1 3/8 (34.9) 300 ~ 780 325 ~ 845 64 64 £14,777.00 £15,046.00 28 hp Multi REYQ12T REYQ16T 78.50 78.50 1685 x 930 1685 x 1240 x 765 x 765 218 305 3.084 4.334 15.3 21.1 25 40 9.9 11.8 61 81 64 86 3/4 (19) 1 1/8 (28.6) 1 3/8 (34.9) 350 ~ 910 64 £16,498.00 Price List Update: Valid from 1st January 2017 81 REYQ-T (30 to 36 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 30 hp Multi REYQ12T Capacity VRV Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) 32 hp Multi REYQ18T 83.90 83.90 1685 x 930 1685 x 1240 x 765 x 765 218 337 3.084 4.184 15.3 24.6 25 40 9.9 11.8 61 81 65 86 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 1/8 (28.6) 1 3/8 (34.9) 375 ~ 975 64 Trade Condensing Unit Price £17,570.00 REYQ16T 34 hp Multi REYQ16T REYQ16T 36 hp Multi REYQ18T 90.00 95.40 90.00 95.40 1685 x 1240 1685 x 1240 1685 x 1240 1685 x 1240 x 765 x 765 x 765 x 765 305 305 305 337 4.334 4.334 4.334 4.184 3 / 50 / 380~415 21.1 21.1 21.1 24.6 4 40 40 40 40 R410A 11.8 11.8 11.8 11.8 data book 64 64 64 65 86 86 86 86 1000 165 3/4 (19.1) 3/4 (19.1) 1 1/8 (28.6) 1 1/8 (28.6) 1 3/8 (34.9) 1 3/8 (34.9) 400 ~ 1040 425 ~ 1105 64 64 £19,186.00 £20,258.00 REYQ16T REYQ20T 101.00 101.00 1685 x 1240 1685 x 1240 x 765 x 765 305 337 4.334 4.350 21.1 31.1 40 50 11.8 11.8 64 86 66 88 3/4 (19.1) 1 1/8 (28.6) 1 5/8 (41.3) 450 ~ 1170 64 £21,444.00 REYQ-T (38 to 42 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 38 hp Multi REYQ12T 1685 x 930 x 765 218 3.084 1685 x 1240 x 765 337 4.184 111.90 111.90 1685 x 930 x 765 8.9 15.3 24.6 11.8 20 25 40 25 9.7 11.8 9.8 65 86 58 79 Capacity Index Limit Maximum Number of Connected Indoor Units 9.9 data book 61 81 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 475 ~ 1235 64 Trade Condensing Unit Price £22,754.00 Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems 82 Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) Residential, Commercial and Industrial REYQ12T 1685 x 930 x 765 106.30 106.30 1685 x 930 x 765 210 2.700 40 hp Multi REYQ10T Capacity REYQ8T 58 78 REYQ18T 218 2.917 218 3.084 3 / 50 / 380~415 15.3 4 25 R410A 9.9 data book 61 81 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 500 ~ 1300 64 £23,264.00 42 hp Multi REYQ18T REYQ10T REYQ16T REYQ16T 1685 x 1240 x 765 305 4.334 1685 x 1240 x 765 337 4.184 1685 x 930 x 765 218 2.917 118.00 118.00 1685 x 1240 x 765 305 4.334 24.6 11.8 21.1 21.1 40 25 40 40 11.8 9.8 11.8 65 86 58 79 11.8 data book 64 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 525 ~ 1365 64 £24,880.00 64 86 REYQ-T (44 to 48 hp) VRV IV Condensing Units – Heat Recovery 44 hp Multi REYQ12T Capacity REYQ14T 218 3.084 1685 x 1240 x 765 305 4.334 1685 x 1240 x 765 319 3.717 15.3 21.1 21.1 17.4 25 40 40 32 9.9 11.8 11.8 64 86 61 81 Capacity Index Limit Maximum Number of Connected Indoor Units 11.8 data book 64 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 550 ~ 1430 64 Trade Condensing Unit Price £26,091.00 Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm 46 hp Multi REYQ16T 123.50 123.50 1685 x 1240 x 765 305 4.334 Dimensions Nominal Cooling Nominal Heating Height x Width x Depth REYQ16T kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) 1685 x 930 x 765 61 81 REYQ16T 130.00 130.00 1685 x 1240 x 765 305 4.334 3 / 50 / 380~415 21.1 4 40 R410A 11.8 data book 64 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 575 ~ 1495 64 48 hp Multi REYQ16T REYQ16T REYQ16T REYQ16T 1685 x 1240 x 765 305 4.334 1685 x 1240 x 765 305 4.334 135.00 135.00 1685 x 1240 x 765 305 4.334 1685 x 1240 x 765 305 4.334 21.1 21.1 21.1 21.1 40 40 40 40 11.8 11.8 11.8 64 86 64 86 11.8 data book 64 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 600 ~ 1560 64 £27,327.00 VRV Outdoor Units 64 86 £28,779.00 REYQ-T (50 to 54 hp) VRV IV Condensing Units – Heat Recovery Outdoor Units 50 hp Multi 52 hp Multi REYQ16T REYQ16T 1685 x 1240 x 765 305 4.334 140.40 140.40 1685 x 1240 x 765 305 4.334 1685 x 1240 x 765 337 4.184 1685 x 1240 x 765 305 4.334 21.1 21.1 24.6 21.1 40 40 40 40 11.8 11.8 11.8 65 86 64 86 Capacity Index Limit Maximum Number of Connected Indoor Units 11.8 data book 64 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 625 ~ 1625 64 Trade Condensing Unit Price £29,851.00 Capacity Dimensions Weight Fan Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Systems Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Total Length Maximum Actual Length Liquid Discharge Gas kW kW mm kg m3/sec Phase / Hz / V amps amps amps kg kg dBA dBA m m inch (mm) inch (mm) inch (mm) 64 86 REYQ18T REYQ16T REYQ18T 145.80 145.80 1685 x 1240 x 765 337 4.184 3 / 50 / 380~415 24.6 4 40 R410A 11.8 data book 65 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 650 ~ 1690 64 £30,923.00 54 hp Multi REYQ18T REYQ18T REYQ18T REYQ18T 1685 x 1240 x 765 337 4.184 1685 x 1240 x 765 337 4.184 151.20 151.20 1685 x 1240 x 765 337 4.184 1685 x 1240 x 765 337 4.184 24.6 24.6 24.6 24.6 40 40 40 40 11.8 11.8 11.8 65 86 65 86 11.8 data book 65 86 1000 165 3/4 (19.1) 1 3/8 (34.9) 1 5/8 (41.3) 675 ~ 1755 64 65 86 £31,995.00 Price List Update: Valid from 1st January 2017 83 RXYQQ-T / RQEQ-P3 Replacement VRV-Q VRV Optimise your business Tackle more projects in less time: New Lower installation costs: Now it's possible to connect VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest & most flexible range of design & installation options available. Due to faster installation. VRV-Q is more cost-effective than replacing the full system with new piping. Offer customers the overall lowest cost solution and improve your competitive edge. Easy as one-two-three: A simple solution: Daikin VRV-Q enables you to handle more projects for more customers in less time and offer them the best price! Everybody wins. Compare installation steps Conventional solution 1 Recover refrigerant 2 Remove units 3 Remove refrigerant pipes VRV-Q 1 Recover refrigerant 2 Remove units Re-use existing piping and wiring 5 Install new units 3 Install new units 6 Leak test 4 Leak test 7 Vacuum drying 5 Vacuum drying 9 Collect contamination 10 Test operation 4 6 Automatic refrigerant charging, cleaning and testing Reuse drain pipes Durable PVC pipes can be easily reused. Only flow tests are required. 4 4 Install new piping/wiring 8 Refrigerant charging The Daikin low-cost upgrade solution Reuse refrigerant pipes Pipes used for R-22 will also work with VRV-Q, thanks to lower operating pressures of the system. 4 Reuse refrigerant branch pipes There are no restrictions when upgrading from a Daikin VRV system. Other VRF systems require branch pipes to withstand pressure up to 3.3 MPa. ! Replace indoor units and BS boxes Contact your local dealer to check compatibility in case you need to keep the indoor units. 4 Reuse remote control wiring Reuse wiring when upgrading from a Daikin VRV system. In other cases, this will depend on the cable type. Up to 45% shorter installation time Customer benefits 4 Reuse indoor-outdoor wiring Restrictions: see remote control wiring. ! Replace outdoor units Always operational Avoid loss of business Replacing now prevents unplanned, lengthy disruption of air conditioning systems. It also avoids loss of business for shops, complaints from guests in hotels, lower working efficiency and loss of tenants in offices. Reduced energy consumption Up to 40% energy saving Quick and easy installation No interruption of daily business while replacing the system thanks to phased-in, fast installation. Comparison of 10hp systems: Lower long-term costs Repairing systems with R-22 has been prohibited since 31 December 2014. Installing a technically advanced Replacement VRV-Q system reduces energy consumption and maintenance costs from day one. 84 Residential, Commercial and Industrial Cooling mode Heating mode R-22 (RSXY-KA7) R-407C (RSXYP-L7) R-410A (RXYQQ-T) Key Guidelines for a Quality Replacement with VRV-Q VRV R22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. However, both new and recycled sources of R22 are now banned. Many systems today are still running on R22. But as R22 is no longer available, now’s the time to replace R22 systems. The good news is that Daikin’s VRV-Q solution delivers significantly higher energy efficiencies, with the potential of saving up to 50%, compared with installing a completely new system. The Daikin low-cost upgrade solution 4 Reuse drain pipes Durable PVC pipes can be easily reused. Only flow tests are required. 4 Reuse refrigerant pipes Pipes used for R-22 will also work with VRV-Q, thanks to lower operating pressures of the system. 4 Reuse refrigerant branch pipes There are no restrictions when upgrading from a Daikin VRV system. Other VRF systems require branch pipes to withstand pressure up to 3.3 MPa. ! Replace indoor units and BS boxes Contact your local dealer to check compatibility in case you need to keep the indoor units. 4 Reuse remote control wiring Reuse wiring when upgrading from a Daikin VRV system. In other cases, this will depend on the cable type. 4 Reuse indoor-outdoor wiring Restrictions: see remote control wiring. ! Replace outdoor units Refrigerant branch pipes Refrigerant oil Refrigerant branch pipes, including those from other manufacturers, Y-refnets, T-refnets and headers, can be reused under the following conditions: Refrigerant piping can be reused if one of the following oils was used: Barrel Freeze, Ethereal, Ester, Ferreol, HAB, MS, Suniso. ✓ Pipes are corrosion-free ✓ Pipes are insulated ✓ Pipes can withstand a pressure up to 3.3 MPa ✓ There are no special components that implement decompression (e.g. oil trap) ✓ Installed copper pipework is in suitable condition (piping thickness will generally meet specifications, since the unique Daikin VRV solution operates at lower pressure levels) Maximum piping lengths and level distances VRV-Q can be installed for piping systems with a total length up to 300m. See data book for further guidelines. Price List Update: Valid from 1st January 2017 85 RXYQQ-T (up to 20 hp) VRV IV-Q Condensing Unit – Heat Pump Outdoor Units RXYQQ8T RXYQQ10T RXYQQ12T RXYQQ14T RXYQQ16T RXYQQ18T RXYQQ20T 22.40 25.00 4.30 7.53* 4.54 1685 930 765 187 2.700 28.00 31.50 3.84 7.20* 4.27 1685 930 765 194 2.917 33.50 37.50 3.73 6.96* 4.12 1685 930 765 194 3.083 45.00 50.00 3.46 6.50* 3.91 1685 1240 765 305 3.883 50.00 56.00 3.40 6.38* 3.89 1685 1240 765 314 4.183 56.00 63.00 3.03 5.67* 3.71 1685 1240 765 314 4.350 8.4 11.5 14.2 20.6 23.4 29.5 20 25 32 40 40 50 5.9 6.0 6.3 10.4 11.7 11.8 58 78 58 79 61 81 64 86 65 86 66 88 Capacity Index Limit Maximum Number of Connected Indoor Units 3/8 (9.5) 3/4 (19.1) 100~260 64 3/8 (9.5) 7/8 (22.2) 125~325 64 1/2 (12.7) 1 1/8 (28.6) 150~390 64 40.00 45.00 3.64 6.83* 4.02 1685 1240 765 306 3.717 78 3 / 50 / 380~415 17.2 4 32 R410A 10.3 data book 61 81 120 50 1/2 (12.7) 1 1/8 (28.6) 175~455 64 1/2 (12.7) 1 1/8 (28.6) 200~520 64 5/8 (15.9) 1 1/8 (28.6) 225~585 64 5/8 (15.9) 1 1/8 (28.6) 250~650 64 Trade Condensing Unit Price £5,281.00 £5,770.00 £6,693.00 £7,809.00 £9,012.00 £10,572.00 £11,608.00 Capacity VRV EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Nom Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) *The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. RXYQQ-T (22 to 28 hp) VRV IV-Q Condensing Unit – Heat Pump Outdoor Units RXYQQ22T RXYQQ10T Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Nom Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) RXYQQ24T RXYQQ12T RXYQQ8T 61.50 69.00 3.78 7.07* 4.19 1685 930 765 194 2.917 RXYQQ16T RXYQQ26T RXYQQ12T 67.40 75.00 3.70 6.81* 4.10 1685 930 765 194 3.083 1685 930 765 187 2.100 11.5 14.2 8.4 25 32 20 6.0 6.3 5.29 58 79 61 81 58 78 RXYQQ28T RXYQQ14T RXYQQ12T 73.50 82.50 3.68 6.89* 4.06 1685 1240 765 305 3.883 1685 930 765 194 3.083 RXYQQ16T 78.50 87.50 3.57 6.69* 4.00 1685 1240 765 306 3.717 1685 930 765 194 3.083 1685 1240 765 305 3.883 17.2 14.2 20.6 32 32 40 10.3 6.3 10.4 61 81 61 81 64 86 78 3 / 50 / 380~415 20.6 14.2 4 40 32 R410A 10.4 6.3 data book 64 61 86 81 120 50 Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 1 1/8 (28.6) 275~715 64 5/8 (15.9) 1 3/8 (34.9) 300~780 64 3/4 (19.1) 1 3/8 (34.9) 325~845 64 3/4 (19.1) 1 3/8 (34.9) 350~910 64 Trade Condensing Unit Price £12,463.00 £14,293.00 £14,502.00 £15,705.00 *The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. 86 Residential, Commercial and Industrial RXYQQ-T (30 to 36 hp) VRV IV-Q Condensing Unit – Heat Pump RXYQQ30T RXYQQ12T Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Nom Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) RXYQQ32T RXYQQ18T RXYQQ16T 83.50 93.50 3.53 6.60* 3.98 1685 930 765 194 3.083 RXYQQ34T RXYQQ16T RXYQQ16T 90.00 100.00 3.50 6.50* 3.90 1685 1240 765 314 4.183 1685 1240 765 305 3.883 14.2 23.4 20.6 32 40 40 6.3 11.7 10.4 61 81 65 86 64 86 RXYQQ36T RXYQQ18T RXYQQ16T 95.00 106.00 3.40 6.44* 3.90 1685 1240 765 305 3.883 1685 1240 765 305 3.883 RXYQQ20T 101.00 113.00 3.20 6.02* 3.80 1685 1240 765 314 4.183 1685 1240 765 305 3.883 1685 1240 765 314 4.350 23.4 20.6 29.5 40 40 50 11.7 10.4 11.8 65 86 64 86 66 88 78 3 / 50 / 380~415 20.6 20.6 4 40 40 R410A 10.4 10.4 data book 64 64 86 86 120 50 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 3/8 (34.9) 375~975 64 3/4 (19.1) 1 3/8 (34.9) 400~1040 64 3/4 (19.1) 1 3/8 (34.9) 425~1105 64 3/4 (19.1) 1 5/8 (41.3) 450~1170 64 Trade Condensing Unit Price £17,265.00 £18,024.00 £19,584.00 £20,620.00 VRV Outdoor Units *The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. RXYQQ-T (38 to 42 hp) VRV IV-Q Condensing Unit – Heat Pump Outdoor Units RXYQQ38T RXYQQ8T Capacity Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 5/8 (41.3) 475~1235 64 111.50 125.00 3.61 6.74* 4.05 1685 930 765 194 3.083 78 3 / 50 / 380~415 14.2 4 32 R410A 6.3 data book 61 81 120 50 3/4 (19.1) 1 5/8 (41.3) 500~1300 64 Trade Condensing Unit Price £22,659.00 £23,035.00 EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg m3/sec Pa Phase / Hz / V amps amps amps RXYQQ40T High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Nom Maximum Length Maximum Vertical Rise Liquid Gas kg kg dBA dBA m m inch (mm) inch (mm) RXYQQ42T RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T 1685 930 765 187 2.100 106.40 119.50 3.43 6.36* 4.00 1685 930 765 194 2.917 1685 1240 765 314 4.350 1685 930 765 194 2.917 8.4 11.5 29.5 11.5 20 25 50 25 5.9 6.0 11.8 6.0 58 78 58 79 66 88 58 79 RXYQQ16T 1685 1240 765 314 4.183 1685 930 765 194 2.917 118.00 131.50 3.54 6.65* 3.99 1685 1240 765 305 3.883 23.4 11.5 20.6 20.6 40 25 40 40 11.7 6.0 10.4 10.4 65 86 58 79 64 86 64 86 1685 1240 765 305 3.883 3/4 (19.1) 1 5/8 (41.3) 525~1365 64 £23,794.00 *The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation). Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. Price List Update: Valid from 1st January 2017 87 RQCEQ-P3 (28.0 to 45.0 kW) VRV III-Q Condensing Unit – Heat Recovery Outdoor Units RQCEQ280P3 RQEQ140P3 Capacity VRV Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Refrigerant Circuit Sound Pressure Piping Limits Nominal Cooling Nominal Heating Height Width Depth High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Maximum Length Maximum Vertical Rise Liquid Gas Discharge kW kW mm mm mm kg m3/sec Pa Phase Hz V amps amps amps kg kg dBA m m inch (mm) inch (mm) inch (mm) RQCEQ360P3 RQEQ140P3 RQEQ180P3 28.00 32.00 1680 635 765 175 1.583 RQCEQ460P3 RQEQ180P3 RQEQ140P3 RQEQ140P3 36.00 40.00 1680 635 765 175 1.583 1680 635 765 175 1.833 78 1680 635 765 175 1.833 1680 635 765 175 1.583 3ph 50 380~415 8.0 5.5 78 5.5 5.5 8.0 4 15 20 10.3 10.3 10.6 54 58 54 20 R410A 10.6 data book 58 1680 635 765 175 1.833 8.0 15 5.5 4 15 10.3 10.3 10.6 54 54 120 58 4 15 20 120 120 Capacity Index Limit Maximum Number of Connected Indoor Units 3/8 (9.5) 7/8 (22.2) 3/4 (19.1) 140~325 21 1/2 (12.7) 1 (25) 3/4 (19.1) 180~422.5 28 1/2 (12.7) 1 1/8 (28.6) 7/8 (22.2) 230~520 34 Trade Condensing Unit Price £6,834.00 £8,788.00 £11,228.00 Piping Connections RQEQ180P3 45.00 52.00 1680 635 765 175 1.583 78 50 Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. RQCEQ-P3 (50.0 to 63.6 kW) VRV III-Q Condensing Unit – Heat Recovery Outdoor Units RQCEQ500P3 RQCEQ540P3 RQCEQ636P3 RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 Capacity Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 1 1/8 (28.6) 7/8 (22.2) 250~585 39 54.00 60.00 1680 635 765 175 1.833 3ph 50 380~415 8.0 4 20 R410A 10.6 data book 58 120 50 5/8 (15.9) 1 1/8 (28.6) 7/8 (22.2) 270~650 43 Trade Condensing Unit Price £12,205.00 £13,182.00 Dimensions Weight Air Flow Rate Electrical Details Refrigerant Circuit Sound Pressure Piping Limits Piping Connections Nominal Cooling Nominal Heating Height Width Depth Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Maximum Length Maximum Vertical Rise Liquid Gas Discharge kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps kg kg dBA m m inch (mm) inch (mm) inch (mm) 1680 635 765 175 1.583 50.00 56.00 1680 635 765 175 1.833 1680 635 765 175 1.833 1680 635 765 175 1.833 8.0 8.0 15 8.0 4 20 20 20 10.3 10.6 10.6 10.6 54 58 58 58 5.5 1680 635 765 175 1.833 1680 635 765 179 1.833 8.0 11.5 20 63.60 67.20 1680 635 765 179 1.833 1680 635 765 179 1.833 11.5 20 11.5 4 20 10.6 11.2 11.2 11.2 58 60 60 60 20 5/8 (15.9) 1 1/8 (28.6) 1 (25) 318~715 47 £15,537.00 Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. 88 Residential, Commercial and Industrial RQCEQ-P3 (71.2 to 74.4 kW) VRV III-Q Condensing Unit – Heat Recovery RQCEQ712P3 RQEQ140P3 Capacity Dimensions Weight Air Flow Rate Electrical Details Refrigerant Circuit Sound Pressure Piping Limits Piping Connections Nominal Cooling Nominal Heating Height Width Depth Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Maximum Length Maximum Vertical Rise Liquid Gas Discharge kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps RQEQ180P3 RQEQ180P3 RQCEQ744P3 RQEQ212P3 RQEQ140P3 RQEQ180P3 71.20 78.40 1680 635 765 175 1.583 1680 635 765 175 1.833 RQEQ212P3 RQEQ212P3 74.40 80.80 1680 635 765 175 1.833 1680 635 765 179 1.833 1680 635 765 175 1.583 1680 635 765 175 1.833 5.5 8.0 1680 635 765 179 1.833 1680 635 765 179 1.833 11.5 11.5 VRV Outdoor Units 3ph 50 350~415 5.5 8.0 8.0 11.5 4 15 4 20 20 20 15 20 20 20 10.3 10.6 11.2 11.2 54 58 60 60 R410A kg kg dBA m m inch (mm) inch (mm) inch (mm) 10.3 10.6 10.6 11.2 data book 54 58 58 60 120 50 Capacity Index Limit Maximum Number of Connected Indoor Units 5/8 (15.9) 1 1/8 (28.6) 1 (25) 356~780 52 3/4 (19.1) 1 3/8 (34.9) 1 (25) 372~845 56 Trade Condensing Unit Price £17,384.00 £18,169.00 Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. RQCEQ-P3 (81.6 to 84.8 kW) VRV III-Q Condensing Unit – Heat Recovery Outdoor Units RQCEQ816P3 RQEQ180P3 Capacity Dimensions Weight Air Flow Rate Electrical Details Refrigerant Circuit Sound Pressure Piping Limits Piping Connections Nominal Cooling Nominal Heating Height Width Depth Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Nom Maximum Length Maximum Vertical Rise Liquid Gas Discharge kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps RQEQ212P3 RQEQ212P3 RQCEQ848P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 81.60 87.20 1680 635 765 175 1.833 1680 635 765 179 1.833 RQEQ212P3 RQEQ212P3 84.80 89.60 1680 635 765 179 1.833 1680 635 765 179 1.833 1680 635 765 179 1.833 1680 635 765 179 1.833 11.5 11.5 1680 635 765 179 1.833 1680 635 765 179 1.833 11.5 11.5 3ph 50 380~415 8.0 11.5 11.5 11.5 4 20 4 20 20 20 20 20 20 20 11.2 11.2 11.2 11.2 60 60 60 60 R410A kg kg dBA m m inch (mm) inch (mm) inch (mm) 10.6 11.2 11.2 11.2 data book 58 60 60 60 120 50 Capacity Index Limit Maximum Number of Connected Indoor Units 3/4 (19.1) 1 3/8 (34.9) 1 1/8 (28.6) 408~910 60 3/4 (19.1) 1 3/8 (34.9) 1 1/8 (28.6) 424~975 64 Trade Condensing Unit Price £19,931.00 £20,716.00 Please see note on page 91 regarding VRV-Q warranty, and contact your local sales office for more information on VRV-Q installation. Price List Update: Valid from 1st January 2017 89 Y E N E R G P TO GS U SAVIN Daikin Network Service System (DNSS) Remote Monitoring and Lifecycle Management 25% VRV DNSS is a remote monitoring system, which will allow you to continuously optimise the running of your Daikin equipment; control your energy consumption (so reduce your Carbon Footprint), extend the life span of your equipment and reduce operational costs. Prevent product malfunctions The DNSS will analyse the data from your equipment every minute of the day and will alert us before the equipment actually breaks down. In this way, failures can be prevented and possible down time reduced to an absolute minimum. Remote diagnostics The DNSS continuously checks the cleanliness of the system filters and heat exchanger. Furthermore, the DNSS manages a wide range of data (pressures, temperatures, running hours, etc.) in order to let your equipment run as efficiently and trouble free as possible. This will also prevent your equipment from using too much energy. E UNIQU N BY O I AT INNOV IKIN A D Extend product lifetime The DNSS is designed to make sure that your equipment is maintained and running as efficiently as possible. This optimisation will extend the lifespan of your equipment. Malfunction messages In the unlikely event of a problem occurring, your regional Daikin UK office will contact you directly. Our engineers, who are dedicated to your installation, will inform you regarding the nature of the problem and will help you towards the next step of solving the problem. Your installation under continuous monitoring > > > > > > > 24/7, 365 days a year remote monitoring Predictive maintenance Improved reliability Improved comfort levels Helps increase efficiency Helps reduce maintenance costs Extends product lifetime Extra value at low cost > A strategy of preventing breakdowns and limiting unnecessary maintenance visits > Efficiently organising site interventions by diagnosing the nature and the extent of the problem before going to site > Innovative technology that helps to optimise your equipment’s potential > Ensures the most comfortable environment in your premises Installation requirements: > DNSS requires an Intelligent Touch Controller or Intelligent Touch Manager to be installed on site, to act as the data relay point > The controller cost is not included in the Commissioning price, but must be purchased separately > A Lan connection must be provided local to the installed controller with the ability to make an outgoing connection to the internet > Alternatively a 3G connection can be supplied by Daikin at an additional cost Commissioning Model Description Trade Price UK.FS-DNSS1-3VRV UK.FS-DNSS4-6VRV UK.FS-DNSS7-9VRV UK.FS-DNSS10-12VRV UK.FS-DNSS13-15VRV UK.FS-DNSS16-18VRV UK.FS-DNSS19-21VRV DNSS is sold at nett price. No discounts will apply DNSS commissioning of 1 to 3 VRV systems DNSS commissioning of 4 to 6 VRV systems DNSS commissioning of 7 to 9 VRV systems DNSS commissioning of 10 to 12 VRV systems DNSS commissioning of 13 to 15 VRV systems DNSS commissioning of 16 to 18 VRV systems DNSS commissioning of 19 to 21 VRV systems £450.00 £500.00 £600.00 £700.00 £800.00 £1,000.00 £1,200.00 90 Residential, Commercial and Industrial Annual monitoring Model Description Trade Price DNSS is sold at nett price. No discounts will apply UK.FS-DNSS/VRV/IND Annual DNSS monitoring of a single £150.00 module VRV system UK.FS-DNSS/VRV/2ND Annual DNSS monitoring of a twin £200.00 module VRV system UK.FS-DNSS/VRV/3ND Annual DNSS monitoring of a triple £250.00 module VRV system VRV-Q Warranty Warranty and site services VRV The warranty for VRV-Q systems operates under different conditions from our standard warranty. To ensure complete suitability of the existing site, a choice of optional warranty and special site services packages are available from Daikin Airconditioning UK Ltd. These choices will ensure the VRV-Q system is designed and commissioned to provide the client with complete ‘peace of mind’ operation. The choices include: a) Pre-order checks on the existing pipework and fan coils installed on the clients’ site to ensure suitability for VRV-Q installation b) Commissioning of the new VRV-Q installation to ensure correct and efficient operation Warranty options for 3 or 5 years are available depending on the qualification criteria and the type of system being installed. Commissioning Log Books should be available for inspection by Daikin Airconditioning UK Ltd if required. The tables below provide an overview of the choices. For full details please contact your local sales office. VRV-Q Warranty Choices 1. VRV-Q combined with new fan coil units Warranty Package Level For Site with New Fan Coils non D1/D1+ Condensing Unit Warranty Period Fan Coil Unit Warranty Period Site Pre-Order Inspection Commissioning D1/D1+ 3 Years 5 Years 3 Years 5 Years By trained approved engineer (1) OR by Daikin Airconditioning UK Ltd (additional cost) By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost) 2. VRV-Q combined with existing fan coil units Warranty Package Level For Site with Existing Fan Coils non D1/D1+ Condensing Unit Warranty Period Existing Fan Coil Unit Warranty Period Site Pre-Order Inspection Commissioning D1/D1+ 3 Years 5 Years 0 Years 0 Years By trained approved engineer (1) (2) OR by Daikin Airconditioning UK Ltd (additional cost) By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost) Notes: (1) (2) Approved engineer to sign commissioning report and be able to identify DAUK official training programme attended, SE19 VRV-Q required Trained approved engineer to collect 2 hours of data per system from the service checker for assessment Daikin Support Options Site pre-order inspection per system* Site pre-inspection (existing fan coils) including 2 hour service checker analysis per system* Daikin commissioning per system* Daikin full day commissioning assistance Cost Code £175.00 £285.00 UK.SFV/N/INSP UK.SFV/E/INSP £400.00 £585.00 UK.SFV/SYCOMM UK.SFV/FULLCOMM *System is defined as a maximum of 3 connected condensers. All prices shown are Net. No further discount can be applied. Price List Update: Valid from 1st January 2017 91 VRV VRV-Q Warranty Detail Approved engineer An approved engineer is an engineer who: 1. Is suitably registered in accordance with F-gas regulations 2. Has successfully completed a Daikin Airconditioning UK Ltd VRV Air Cooled installation and commissioning course within the last 3 years 3. Has completed SE19 VRV-Q course in the past 3 years • Check status of the existing indoor units – necessary if the existing units are to be reused • Check filter condition • Check coil condition • Check fan motor operation – select fan only and check for air movement and for unusual noise and vibration Net price Net price, exclusive of VAT and subject to our standard terms and conditions. No other discounts are applicable. Prices shown for site pre-order inspection and commissioning are for work undertaken during normal working hours between 09:00 and 17:30. Any request for attendance to site out of these hours is subject to additional charges. • Installed pipework details – necessary to check compliance with the manufacturer’s specification and assess install quality. This would highlight any required rectification prior to the installation of the new system • Provide as installed pipework diagrams. If not available, provide as installed pipe work schematics from information gathered on site • Check the distance from the outdoor to the farthest indoor along the pipe work route • Check the distance from the first Refnet fitting to the farthest indoor unit • Check the height difference between the outdoor and the lowest indoor when the outdoor is situated above the indoor units or height difference between the outdoor and the highest indoor if the outdoor is situated below the indoor units • Check the height difference between the highest and the lowest indoor connected to the same system • Provide the lengths of all installed pipe sizes • Check the installation position and angle of the Refnet Joints • Check the condition of the pipe insulation • Check the adequacy of the existing pipe supports Warranty To activate the warranty, the Daikin Airconditioning UK Ltd VRV Commissioning Log Book will need to be fully completed and submitted to Daikin Airconditioning UK Ltd FQS department for checking. Upon receipt and validation that all required details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a confirmation letter that the warranty is activated. Where Daikin Airconditioning UK Ltd will complete the commissioning, we will provide a copy of the Commissioning Log Book to the installation contractor. Except where mentioned above, our standard warranty conditions will apply. If none of the packaged options are chosen, then the warranty will be limited to a standard 12 month parts only cover. Site pre-order inspection Where required, Daikin Airconditioning UK Ltd will attend the site to check the suitability of the existing equipment and pipework for connection to VRV-Q. Where it is not possible to check operation or equipment condition, this will also be highlighted in the final report, and appropriate recommendations made. If an approved engineer carries out the site inspection, then a Daikin Airconditioning UK Ltd supplied form shall be completed and submitted to our FQS department for checking and approval prior to any order being accepted. The pre-order site inspection will include the following items: • Existing system(s) capacity – necessary to estimate required system load for the new system • Record all the model numbers and the serial numbers for the indoor and the outdoor units and indicate actual installed system combinations 92 Residential, Commercial and Industrial • Installed communication and control wiring – necessary to check compliance with the manufacturer’s specification, suitability for the new system and suitability for new controls specification • Check sizes and type of the interconnecting communication cables between indoor units, outdoor units and any central control systems • Check the separation between the power wiring and the installed controls wiring • Power wiring to the outdoor units – necessary to check suitability for the new outdoor units • Check supply voltage • Check number of outlets available adjacent to the outdoor units compound • Check fuse/MCB sizes and types • Check status of the isolators • System health checks – it is important to know if the existing systems are operating to their optimum. If there are issues which may affect the new installation they need to identified and rectified before installation of the new system. A comprehensive list of the operating data can be collected by connecting a VRV Checker to each system and recording a minimum of one hour operation data for analysis. This data should be sent back to Daikin Airconditioning UK Ltd FQS department for analysis • Operate the whole system in cooling for ½ hour and in heating for ½ hour to collect representative data • Send data to Daikin Airconditioning UK Ltd FQS department for analysis • System history check – although the new VRV-Q system is designed to re-use existing pipework and in some cases existing indoor units it is still necessary to know the existing systems operational history to judge its integrity for the new application • Check for presence of leak protection dye and acid level – use total test kit • Ensure that no Acid Away chemical has ever been added to the system refrigerant charge • Existing system controls – investigate currently installed local controls, centralised controls and connection to the third party systems. This is particularly necessary if any existing controls are planned to be re-used Commissioning Dependant on the requirement, either an approved engineer or Daikin Airconditioning UK Ltd will provide system commissioning on the completed installation. As mentioned in the warranty section above, a completed log book will need to be submitted to activate the warranty Commissioning where not provided by Daikin Airconditioning UK Ltd, can only be completed by an approved engineer. Where Daikin Airconditioning UK Ltd provides commissioning as part of the package this shall include: • Check installation of new units – ensure new piping is installed correct to Daikin specification • Check power supplies – local isolators, MCB rating • Fill in model number data, serial numbers etc. to commissioning log book • Initialise VRV System and ensure all units communicate • Set up additional control systems – ITC, Bacnet and provide demonstration • Charge additional refrigerant • Perform “Test” operation – including “Automatic” charging function • Connect service checker and monitor operation – Cool>Heat>Heat Recovery • Complete Commissioning Log Book • Provide additional comments and recommendations if necessary • Leave operation set as required by client DNSS (Daikin Network Service System) Where Daikin Airconditioning UK Ltd provide DNSS this shall include the following items: • Commissioning of DNSS system (on-site service) • GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd) • Remote energy saving service • 24/7 monitoring of VRV operating data • Instant notification of system malfunction (email) 7 days a week • Malfunction prediction service (during office hours 09.00 - 17.30) • Bi-annual energy saving report indicating electricity cost saving and reduction in CO2 emissions • Recommendations to improve operating settings • Issue of a DNSS user pack All of the above will be provided for the warranty period of the VRV (either 3 or 5 years) depending on the package selected. Prior to our site attendance the following shall be completed: • A device compatible with DNSS is installed on site – Daikin Intelligent Manager, Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the price of the monitoring package) • All electrical work is complete and correct (supply wiring type and size – breaker size correct) also F1/F2 communications are installed • A full set of as installed drawings are available – indicating system configurations, installation locations and room references • A power source is installed for the GPRS modem near the control device – this can be powered from a standard socket • A connection to the internet is available – for areas where there is poor GPRS coverage a LAN or analogue phone connection must be installed near the control device. (Installation and rental costs are not included in the price of the monitoring package) • Full access must be made available to the VRV equipment and if any access equipment is required Daikin UK must be informed prior to the site visit • A list of contacts must be issued to Daikin Airconditioning UK Ltd (these are the contacts that should be e-mailed or telephoned in the event of a malfunction or error with the air conditioning system). If these change in the future, information will be given in the user pack for how to notify Daikin Airconditioning UK Ltd of the changes This is an extract from the Daikin publication “Warranty and Site Services Package for VRV-Q”. Please contact your local sales office to receive a copy and obtain further information. Prior to our site attendance the following shall be completed: • All communication wiring is complete and terminated correctly • All electrical work is complete and correct (supply wiring type and size – Breaker size correct) • All systems piping has been pressure tested to 33 Bar • All systems piping has been evacuated to < 5 Torr • All systems piping has been measured and is available for our information • Sufficient additional refrigerant is available on the day Any other works other than those detailed above are excluded. Price List Update: Valid from 1st January 2017 93 VRV VRV-Q Warranty Detail RWEYQ-T8 Water Cooled VRV VRV Water cooled VRV uses water as its source of heat. This enables not just heat recovery on each system, but also heat recovery between different systems, maximising efficiency. Additionally there is no defrost required on these units meaning heating comfort is maintained even during cold spells. Ideal for large buildings VRV-W systems are capable of coping with water pressures of 2MPa and provide pipework lengths of up to 120m length from condenser to fan coils. The new VRV IV features are available on water cooled VRV systems including: > T he standard model is now capable of accepting geothermal water temperatures (Down to -10 Deg C with glycol) > Variable Refrigerant Temperature – delivering far higher efficiency than any other comparable system and ensuring comfort by raising off coil temperatures, Variable Refrigerant Temperature control delivers a leap forwards in VRV technology. > Inverter water pump controller (available on request) onfigurator – Simplified commissioning: graphical interface > C to configure, commission and upload system settings. Manage systems over multiple sites, saves time and reduces errors during set-up and commissioning. onnect to AHU applications and Heat Reclaim Ventilation devices > C > Now it’s even possible to connect VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest & most flexible range of design & installation options available. Water flow control Significantly reduce inverter pump power input by reducing the flow through the VRV-W condenser when at part load. By linking the degree of valve opening to the compressor frequency, the flow rate varies to match the load. Consequently as the flow rate reduces, the inverter pump will slow down and save energy. > Up to 13 steps of flow control available > Available as an option (factory fitted) > 50l/m minimum flow rate Chiller / Boiler Variable water Flow Control Valve Wired connection Inverter Pump 94 Residential, Commercial and Industrial Heat Pump and Heat Recovery RWEYQ-T8 (up to 24 hp) VRV IV Water Cooled Condensing Units Capacity EER COP Dimensions Weight Electrical Details Refrigerant Circuit RWEYQ8T8 RWEYQ10T8 Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg Phase / Hz / V amps amps amps Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge 22.40 25.00 5.07 5.94 1000 780 550 137 7.2 4 20 kg kg Sound Pressure dBA Piping Limits Maximum Length m Maximum Vertical Rise m Liquid inch (mm) Piping Connections Gas (Heat pump) Suction (HR) inch (mm) Gas Discharge (HR only) inch (mm) Drain Outlet Water Inlet & Outlet Capacity Index Limit Maximum Number of Connected Indoor Units 3.5 data book 50 120 50 3/8 (9.52) 3/4 (19.1) 5/8 (15.9) Trade Condensing Unit Price £5,745.00 £7,080.00 100~260 36 RWEYQ16T8 RWEYQ18T8 RWEYQ20T8 RWEYQ24T8 RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 28.00 44.80 50.40 56.00 67.20 31.50 50.00 56.50 63.00 75.00 4.56 5.07 4.77 4.56 5.07 5.25 5.94 5.53 5.25 5.94 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 780 780 780 780 780 780 780 780 780 780 550 550 550 550 550 550 550 550 550 550 137 137 137 137 137 137 137 137 137 137 3 / 50 / 380~415 9.5 14.4 16.7 19.0 21.6 4 4 4 4 4 20 32 32 32 50 R410A 4.2 3.5 3.5 3.5 4.2 4.2 4.2 3.5 3.5 3.5 data book data book data book data book data book 51 53 54 54 55 120 120 120 120 120 50 50 50 50 50 3/8 (9.52) 1/2 (12.7) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 7/8 (22.2) 1 1/8 (28.6) 1 1/8 (28.6) 1 1/8 (28.6) 1 3/8 (34.9) 3/4 (19) 7/8 (22.2) 7/8 (22.2) 7/8 (22.2) 1 1/8 (28.6) ISO 228 - G1 1/2 B Internal thread - Per module ISO 228 - G1 1/4 B External thread - Per module 125~325 200~520 225~585 250~650 300~780 36 36 36 36 36 £11,490.00 £12,825.00 £14,160.00 £17,235.00 Notes: Daikin have introduced the new VRV IV Water Cooled condensing unit to complement the rest of the VRV range. The water cooled system has a number of advantages over an air cooled system: • suitable for tall multi-storied buildings due to no limitations of water piping length • wide operation range with inlet water temperatures of -10°C to + 45°C • suitable for use with open and closed loop ground source systems on request • the system offers greater efficiency in heating mode as there is no defrost cycle required for the water loop • greater efficiencies than air cooled systems Heat Pump and Heat Recovery RWEYQ-T8 (26 to 30 hp) VRV IV Water Cooled Condensing Units Outdoor Units RWEYQ26T8 RWEYQ8T8 Capacity EER COP Dimensions Weight Electrical Details Refrigerant Circuit Nominal Cooling Nominal Heating kW kW Height Width Depth mm mm mm kg Phase / Hz / V amps amps amps Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge kg kg Sound Pressure dBA Piping Limits Maximum Length m Maximum Vertical Rise m Liquid inch (mm) Piping Connections Gas (Heat pump) Suction (HR) inch (mm) Gas Discharge (HR only) inch (mm) Drain Outlet Water Inlet & Outlet Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price 1000 780 550 137 3.5 RWEYQ28T8 RWEYQ30T8 RWEYQ8T8 RWEYQ10T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 72.80 78.40 84.00 81.50 88.00 94.50 4.86 4.69 4.56 5.65 5.43 5.25 1000 1000 1000 1000 1000 1000 1000 1000 780 780 780 780 780 780 780 780 550 550 550 550 550 550 550 550 137 137 137 137 137 137 137 137 3 / 50 / 380~415 23.9 26.2 28.5 4.0 4.0 4.0 50 50 50 R410A 3.5 4.2 3.5 4.2 4.2 4.2 4.2 4.2 data book 55 55 56 120 120 120 50 50 50 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 1 3/8 (34.9) 1 3/8 (34.9) 1 3/8 (34.9) 1 1/8 (28.6) 1 1/8 (28.6) 1 1/8 (28.6) ISO 228 - G1 1/2 B Internal thread - Per module ISO 228 - G1 1/4 B External thread - Per module 325~845 350~910 375~975 36 36 36 £18,570.00 £19,905.00 £21,240.00 Notes: The VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply. The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages. It should be installed in a plant room. Price List Update: Valid from 1st January 2017 95 VRV Outdoor Units BS-Q-A VRV Accessories VRV IV Branch Selector Boxes – Heat Recovery VRV The new VRV IV Heat Recovery series has a new range of BS boxes, which are designed to offer unrivalled flexibility – enabling you to install and adapt the systems in as little time, effort and cost as possible. BS1Q10,16,25A Main features: BS4Q14A BS6,8Q14A BS10,12Q14A BS16Q14A > Unlimited unused ports > Smaller, lighter and quieter than comparable products > Fan coils up to 140 class can be attached to a single port All VRV IV Heat Recovery, VRV III-Q replacement and Water Cooled VRV (RWEYQ-T8) now use VRV IV Multi Boxes. Single Boxes for VRV IV Heat Recovery (REYQ-T / RWEYQ-T8 / RQEQ-P3) Dimensions Weight Total Indoor Capacity Number of Fan Coil Units Electrical Details HxWxD Piping Limits Piping Connections Indoor Piping Connections Outdoor Power Supply Power Input Fuse Rating Level Difference Maximum Length Liquid Gas Liquid Suction Discharge Single Boxes BS1Q10A mm kg Trade Accessory Price Dimensions HxWxD Weight Branches per box Capacity index of each branch Number of Fan Coil Units per branch Total Indoor Capacity Index Total number of Fan Coil units per box Electrical Details Power Supply Power Input Fuse Rating Piping Limits Level Difference Maximum Length Piping Connections Indoor Liquid Gas Piping Connections Outdoor Liquid Suction Discharge BS1Q25A 3/8 (9.5) 5/8 (15.9) 3/8 (9.5) 5/8 (15.9) 1/2 (12.7) £351.00 £387.00 12 15 ~ 100 6 Phase / Hz / V kW amps m m inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Multi Boxes for VRV IV Heat Recovery (REYQ-T / RWEYQ-T8 / RQEQ-P3) BS1Q16A 207 x 388 x 326 12 101 ~ 160 8 1 / 50 / 230 0.005 5 data book data book 3/8 (9.5) 5/8 (15.9) 3/8 (9.5) 5/8 (15.9) 1/2 (12.7) 15 161 ~ 250 8 3/8 (9.5) 7/8 (22.2) 3/8 (9.5) 7/8 (22.2) 3/4 (19.1) £445.00 Multi Boxes BS4Q14AV1B mm kg 298 x 370 x 430 17 4 BS6Q14AV1B BS8Q14AV1B BS10Q14AV1B 298 x 580 x 430 24 6 26 8 BS16Q14AV1B 38 12 298 x 1060 x 430 50 16 50 60 64 0.107 5 0.129 5 0.172 5 35 10 140 or less 5 per branch 400 or less 20 Phase / Hz / V kW amps m m inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) Trade Accessory Price 600 or less 30 750 or less 40 1 / 50 / 230 0.043 5 0.064 5 0.086 5 Data Book 3/8 (9.5) 5/8 (15.9) 3/8 (9.5) 7/8 (22.2) 3/4 (19.1) 3/8 (9.5) 5/8 (15.9) 1/2 (12.7) 1 1/8 (28.6) 3/4 (19.1) 3/8 (9.5) 5/8 (15.9) 1/2 (12.7) 1 1/8 (28.6) 3/4 (19.1) 3/8 (9.5) 5/8 (15.9) 5/8 (15.9) 1 1/8 (28.6) 1 1/8 (28.6) 3/8 (9.5) 5/8 (15.9) 5/8 (15.9) 1 1/8 (28.6) 1 1/8 (28.6) 3/8 (9.5) 5/8 (15.9) 3/4 (19.1) 1 3/8 (34.9) 1 1/8 (28.6) £1,612.00 £2,208.00 £2,904.00 £3,492.00 £4,279.00 £5,209.00 Accessories: Accessory Ref Description Trade Price KHRP26A250T KHFP26M224 KHFP26A100C Junction pipe kit to link two Multi BS ports to connect 20 and 25kW fan coils Stop valve kit for multi BS box future expansion without refrigerant recovery Pipe closing kit for unused ports £292.00 £96.00 £47.00 96 BS12Q14AV1B 298 x 820 x 430 Residential, Commercial and Industrial VRV Accessories VRV IV Branch Selector Boxes with Pre-fitted Valves One of the main benefits of the Daikin VRV multi BS boxes is the flexibility they offer when changing the layout of the system to cater for the changing tenant needs on a building. To further increase the flexibility of the BS boxes, we now offer the full range of multi BS boxes with pre-fitted valves. Having valves pre-installed on the boxes can save considerable time and effort on site. Pre-installed valves allow: VRV > Indoor units to be added without altering system pipework > New units can be added without having to remove refrigerant from the rest of the system • So you can avoid having to pump down / vac out / recharge the whole system • Saves many man hours when altering systems Note: Providing index is not increased above the next pipework threshold or the BS box index limit Model No No. of Ports Original Depth Original Weight *Weight with Valves UK.BS4Q14AV1/FSV UK.BS6Q14AV1/FSV UK.BS8Q14AV1/FSV UK.BS10Q14AV1/FSV UK.BS12Q14AV1/FSV UK.BS16Q14AV1/FSV 4 6 8 10 12 16 mm kg kg 430 BS Box Price Valve Modification Price** 17 22 24 31 26 34 35 45 38 49 50 64 £1,612.00 £266.00 £2,208.00 £372.00 £2,904.00 £478.00 £3,492.00 £584.00 £4,279.00 £690.00 £5,209.00 £902.00 * Approx ** Not subject to standard trade discount RXYSQ, RYYQ, REYQ, RWEYQ VRV Condensing Unit – Refnet Joints For Outdoor Units 2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ Total Capacity of Indoor Units RXYQ5P / RXYSCQ / RXYSQ4-6T RYYQ8-54T / RWEYQ-T Liquid Pipe Suction Pipe Below 62.5 1/4 1/2 KHRQ22M20T £30.00 62.5 to 162.5 3/8 5/8 KHRQ22M20T £30.00 KHRQ22M20T KHRQ22M20T KHRQ22M29T9 KHRQ22M64T KHRQ22M64T KHRQ22M75T KHRQ22M29H KHRQ22M64H KHRQ22M75H BHFQ22P1007 BHFQ22P1517 BHFP22P36C BHFP22P54C £30.00 £30.00 £37.00 £38.00 £38.00 £50.00 £119.00 £145.00 £190.00 £81.00 £159.00 £100.00 £199.00 Below 150 150 to below 200 200 to below 290 290 to below 420 420 to 639 640 and above 3/8 5/8 3/8 3/4 3/8 7/8 1/2 1 1/8 5/8 1 1/8 Please contact your local sales office for selection Refnet Header Refnet Header Refnet Header Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ Condensing Unit Branch Kit - 3 Module RYYQ Condensing Unit Branch Kit - 2 Module RQYQ Condensing Unit Branch Kit - 3 Module RQYQ For Outdoor Units RWEYQ8-30T8 / REYQ-T Trade Price Refnet Selection 3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ Total Capacity of Indoor Units Liquid Pipe Below 150 150 to below 200 200 to below 290 290 to below 420 420 to 639 640 and above 3/8 3/8 3/8 1/2 5/8 Discharge Pipe 1/2 5/8 3/4 3/4 1 1/8 Please contact your local sales office for selection Refnet Header Refnet Header Refnet Header Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ Condensing Unit Branch Kit - 2 Module RQEQ Condensing Unit Branch Kit - 3 Module RQEQ Condensing Unit Branch Kit - 4 Module RQEQ Trade Price Suction Pipe Refnet Selection 5/8 3/4 7/8 1 1/8 1 1/8 KHRQ23M20T KHRQ23M20T KHRQ23M29T9 KHRQ23M64T KHRQ23M64T KHRQ23M75T KHRQ23M29H KHRQ23M64H KHRQ23M75H BHFQ23P907 BHFQ23P1357 BHFP26P36C BHFP26P63C BHFP26P84C £42.00 £42.00 £57.00 £60.00 £60.00 £75.00 £164.00 £198.00 £278.00 £151.00 £305.00 £171.00 £347.00 £460.00 Price List Update: Valid from 1st January 2017 97 NEW Mini Building Management System Mini NEW MiniBuilding BuildingManagement ManagementSystem System NEW Mini Building Management System NEW Mini Building Management System NEW User friendly User friendliness User Userfriendliness friendliness >User Intuitive user interface friendliness Intuitive user interface V isual layout view and direct access to indoor › ››> Intuitive user User friendliness Intuitive userinterface interface lay out view and direct access indoor unit unitlay main functions › ››Visual view and › Visual Intuitive user interface Visual layout out view anddirect directaccess accesstoto toindoor indoorunit unit funtions > A ll functions direct accessible via touch screen main funtions › main Intuitive user interface Visual lay out view and direct access to indoor unit main funtions functions direct accessible via touch screen or viafuntions web interface › ››All functions direct touch › All Visual lay out viewaccessible and directvia access toscreen indoor main All functions direct accessible via touch screen unit via web interface or via web interface main funtions › or All functions direct accessible via touch screen or via web interface › All functions direct accessible via touch screen or via web interface Smart energy management energy management Smart management or viaenergy web interface Smart energy management Smart energy management Monitoring use plan Monitoring ifenergy energy use isaccording according plan › ››> Monitoring if ififenergy use isis toto plan Smart energy management Monitoring energy use isaccording according toto plan detect origins waste Helps detect origins ofenergy waste › ››> Helps toto detect origins ofof waste › Helps Monitoring if energy use isenergy according to plan Helps toto detect origins ofenergy energy waste schedules guarantee correct operation P owerful schedules guarantee correct operation › ››> Powerful schedules guarantee correct › Powerful Monitoring if energy use is according to plan Helps to detect origins of energy waste Powerful schedules guarantee correctoperation operation the year throughout the yearguarantee throughout the year › throughout Helps to detect origins of energy wasteoperation Powerful schedules correct throughout the year energy interlocking A/C operation with other by interlocking operation Save energy › ››> Save energy byby interlocking A/C operation with › Save Powerful schedules guarantee correct operation throughout the year Save energy by interlocking A/CA/C operation withother other equiment such as heating with other equipment such as heating equiment such as heating throughout the year › equiment Save energy by as interlocking such heating A/C operation with other › Save energysuch by interlocking equiment as heating A/C operation with other Flexibility Flexibility equiment such as heating Flexibility Flexibility Flexibility Cross-pillar integration (heating, conditioning, › ›Cross-pillar NEW NEW Cross-pillarintegration integration(heating, (heating,airair airconditioning, conditioning, NEW ›Flexibility systems, refrigeration, handling units) > Cross-pillar integration (heating, air conditioning, conditioning, applied systems, refrigeration, airair units) › applied Cross-pillar integration (heating, air applied systems, refrigeration, airhandling handling units) ››BACnet protocol for 3rd party products integration applied systems, refrigeration, airair handling units) protocol for 3rd integration › BACnet Cross-pillar integration (heating, conditioning, applied systems, refrigeration, air handling units) BACnet protocol for 3rdparty partyproducts products integration ››> I/O for integration of equipment such as lights, for 3rd party products integration B ACnet protocol I/O for integration of equipment such as lights, applied systems, airsuch handling units) › I/O BACnet protocol refrigeration, for 3rd party products for integration of equipment asintegration lights, on WAGO modules >› pumps… I/O for for integration integration of equipment such as as lights, on modules BACnet protocol for 3rd party products integration I/O of equipment such lights, pumps… onWAGO WAGO modules NEW pumps… concept for small large applications pumps etc. WAGO modules › ››Modular concept for small toto applications › Modular I/O for integration of equipment as lights, pumps… onon WAGO modules Modular concept for small tolarge largesuch applications up to 512 indoor unit via one ITM Modular concept formodules small togroups largevia applications › ››> Control up to unit groups pumps… on WAGO › Control Modular for small large applications Control upconcept to512 512indoor indoor unitto groups viaone oneITM ITM and combine multiple ITM via the web interface > 512 indoor unit groups via one ITM C ontrol up to and combine multiple ITM via the web interface › and Modular concept for small to groups large applications Control up tomultiple 512 indoor viainterface one ITM combine ITMunit via the web and combine multiple ITM via the web interface › Control up to 512 indoorITM unit viainterface one ITM and combine multiple viagroups the web Plug play Plug Plug&& &play play Plug & play Plug & play NEW NEW NEW NEW› NEW NEW› Split Split Split Fancoils coils Fan Fan coils Chillersand andAHU AHU Refrigeration Refrigeration Chillers Chillers and AHU Refrigeration Split Fan coils Chillers and AHU Refrigeration Split Fan coils Chillers and AHU Refrigeration Easy servicing and commissioning Easy servicing and combine and multiple ITM via the web interface Easy servicing andcommissioning commissioning Easy servicing and commissioning Remote refrigerant containment check preventing servicing and commissioning › ››Easy Remote refrigerant containment check Easy servicing and commissioning Remote refrigerant containment checkpreventing preventing site visit on site › on Remote refrigerant containment check preventing on sitevisit visit ››> troubleshooting R emote refrigerant containmentcheck checkpreventing Simplifi ed troubleshooting › Simplifi Remote refrigerant containment on site visit Simplified ed troubleshooting ››Save time on commissioning preventing on site visit time on commissioning on site visit › Save Simplifi ed troubleshooting Save time on commissioning to the pre-commissioning tool > Simplified troubleshooting thanks to the pre-commissioning › thanks Simplifi troubleshooting Save time on commissioning tool thanks toed the pre-commissioning tool Auto registration of indoor units S ave time on commissioning thanks › ››> Auto registration of indoor units › Auto Save time on commissioning thanks to the pre-commissioning registration of indoor units tool to the pre-commissioning tool units tool to the pre-commissioning › thanks Auto registration of indoor >› Auto Autoregistration registrationofofindoor indoorunits units › › Functions overview Functions Functionsoverview overview Functions overview Functions overview Functions overview Languages Management Languages Languages 98 Residential, Flexibilityininsize size Flexibility Flexibility in size From6464upuptoto∞∞number number From Flexibility in number size From 64 up to ∞ ofgroups groups of FromFlexibility 64ofup to in number groups ∞size From 64 of upgroups to ∞ number of groups Control Management Management Management Control Control Control Connectable to Connectable Connectabletoto Connectable to English Webaccess access Individualcontrol control - DXSplit, Split,Sky SkyAir, Air, VRV › ›English › ›Web › ›Individual -Connectable DX VRV > DX Split, Sky Air, VRV › Languages English > Web access › Management Web access > Individual control› Control Individual control - DX Split, Sky Air, to VRV French > Power Proportional› ›Power PowerProportional Proportional (2,560 groups) Chillers (via POL638.70 controller) › ›French (2,560 groups) Chillers (via POL638.70 > Chillers (via POL638.70 > Schedule setting (weekly Control Connectable › French English › Power Web access › (2,560 Individual control DXcontroller) Split, Sky Air,to VRVcontroller) › Languages › Management Proportional groups) - -Chillers (via POL638.70 controller) German Distribution (option) Distribution Distribution(option) (option) ›Schedule Schedulesetting setting (Weekly - DaikinAHU AHU › ›German › (Weekly Daikin NEW NEW > Daikin AHU schedule, yearly calender, English ›› Distribution Web access Individual control(Weekly NEW ---Daikin DX Split, SkyPOL638.70 Air, VRV controller) French Power Proportional (2,560 groups) Chillers (via › ›› German (option) › › Schedule setting AHU Italian > Operational history› ›Operational Operationalhistory history schedule,yearly yearly calender, - Fancoils coils › ›Italian >calender, Fan coils NEW- Fan seasonal schedule)schedule, French Power Proportional (2,560 groups) Chillers (via POL638.70 controller) German Distribution (option) › schedule, Schedule setting (Weekly Daikin › ›› Italian › › Operational history yearly calender, ---Fan coilsAHU Spanish (malfunctions, operation seasonalschedule) schedule) - Daikin AlthermaFlex Flextype type (malfunctions, hours, > Daikin Altherma Flex type >operation Interlock control › ›Spanish seasonal Altherma (malfunctions, operation …)…) German Distribution (option) › seasonal Schedule setting (Weekly NEW- Daikin Daikin AHU Italian › (malfunctions, Operational historyhours, schedule, yearly calender, Fan coils › ›› Spanish schedule) ---Daikin Altherma Flex type operation hours, …) > LT and HT hydroboxes hours, …) > Setpoint limitation Dutch ›Interlock Interlockcontrol control - LTand andHTHThydroboxes hydroboxes ›Smart Smartenergy energy management › ›Dutch › LT › management Italian Operational schedule, yearly calender, Fan coils Spanish seasonalcontrol schedule) Daikin Altherma Flex type (malfunctions, operation hours, …) › ›› Dutch › Interlock ---LT and HT hydroboxes › › Smart energyhistory management > Air curtains > Smart energy management > Temperature limit Portuguese Setpointlimitation limitation - Aircurtains curtains - monitorif ifenergy energy useis is › ›Portuguese › ›Setpoint - Air -›monitor use Spanish seasonal schedule) Daikin Flex type operation Dutch Interlocklimitation control LT curtains and Altherma HT hydroboxes Smart energy management › ›› Portuguese › › Setpoint ---Air -(malfunctions, monitor if energy usehours, is …) > WAGO I/O, AO and PI I/O, – monitor if energy useaccording is Temperaturelimit limit - WAGO I/O,AO AOand andPIPI plan › ›Temperature - WAGO toto ›› Dutch Interlock LT HT AO hydroboxes › according Smart energy management Portuguese according to plan according Setpoint control limitation Airand curtains - monitor ifplan energy use is › ›› Temperature limit I/O, and PI to plan > BACnet protocol ----WAGO BACnet protocol - detectorigins originsofofenergy energy System layout BACnet protocol detect System layout NEW NEW › Portuguese ›› Setpoint limitation Air curtains monitor iftoenergy use is Temperature WAGO I/O, AO and PI plan protocol --according detect origins of energy System layout NEW ---BACnet >limit WAGO Interface – detect origins of energy waste Uptoto2,560 2,560unit unitgroups groupscan can waste › ›Up › Temperature limit AO and PI according to plan BACnetI/O, protocol - detect origins of energy layout waste › System Up to 2,560 unit groups can NEW -- WAGO waste ›Setback Setbackfunction function becontrolled controlled WAGO Interface › be WAGO -waste detectfunction origins of energy System layout › be Upcontrolled to 2,560 unit groups can > Setback function › Setback WAGOInterface Interface NEW - BACnet protocol Slidingtemperature temperature (ITMplus plusIntegrator Integrator+temperature +7 iPU 7 iPU Modularintegration integrationofof3rd 3rd › ›Sliding (ITM › ›Modular > Sliding waste › (ITM Up to 2,560 unit groups can Setback function be controlled › › Sliding temperature plus Integrator + 7 iPU › WAGO Modular Interface integration of 3rd (incl.iTM iTMadaptor) adaptor) partyequipment equipment (incl. party ›› Setback function be controlled WAGO Interface Sliding temperature (ITM plusadaptor) Integrator + 7 iPU › party Modular integration of 3rd (incl. iTM equipment Ethernet TCPIP - WAGOcoupler coupler(interface (interface › ›Ethernet TCPIP -› WAGO › Sliding temperature (ITM Integrator integration of 3rd (incl.plus iTM adaptor) + 7 iPU party › Ethernet TCPIP -Modular WAGOequipment coupler (interface betweenWAGO WAGOand andModbus) Modbus) between iTM TCPIP adaptor) party equipment › (incl. Ethernet - WAGO coupler (interface between WAGO and Modbus) - Dimodule module - Di › Ethernet TCPIP WAGO coupler (interface between WAGO and Modbus) - Di module - Domodule module - Do Commercial and Industrial WAGO and Modbus) -Do Di module -between - Aimodule module - Ai Di module Do module ---Ai module - Thermistormodule module - Thermistor Control Systems Control Control Systems Systems Control Systems Control Systems VRV VRV Accessories Mini Building Management System NEW NEW Mini Building Management System Mini Building Management System Check on Check on https://www.youtube.com/ https://www.youtube.com/ DaikinEurope DaikinEurope VRV Accessories System Overview DCM601A51 DCM601A51 with with full full integration integration across across all all product product pillars pillars Price competitive mini BMS Price competitive mini BMS Cross-pillar integration of Daikin products Cross-pillar integration of Daikin products Integration of third party equipment Integration of third party equipment VRV Mini BMS • • • • • • System overview System overview Web Access Web Access Internet Extranet Internet LAN Extranet 3G LAN http interface 3G http interface Integration of third Integration of third party equiqment party equiqment Full control of Daikin Full HVAC-R control of Daikin portfolio HVAC-R portfolio DCM601A51 DCM601A51 ITM plus adaptor line ITM plus adaptor line Di/Pi line Di/Pi200m line Max. Max. 200m Fire alarm Fire alarm Di/Pi port Di/Pi port kWh meter kWh meter Max. 7 adapters Max. 7 adapters DCM601A52 DCM601A52 Direct plug & play connection! Direct plug & play connection! Lighting Lighting Fan Fan Pump Pump Sensor Sensor air curtain, hydrobox, hydrobox, air handling units air handling units Refrigeration Referigeration Referigeration indoor units, indoor units, air curtain, Chillers Chillers andand AHU AHU WAGO WAGO interface interface I/OI/O module module I/OI/O module module BACnet BACnet protocol protocol FanFan coilcoil units units Split Split Multi state objects Multi state objects Elevator Elevator Air handling unit Air handling unit Alarm Alarm 224 224 Price List Update: Valid from 1st January 2017 ECPEN15-200.indd 224 99 12/02/15 11:47 VRV Accessories Remote Controllers (supplied loose) VRV Remote Control Options Model Description Related Fan Coil Trade Price BRC1E53A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock All £79.00 BRC2E52C Premium wired controller with simplified outlook All £83.00 UK.BRC2E/CHR/POL Polished chrome simplified controller, recessed in wall All £188.00 UK.BRC2E/CHR/BRU Brushed chrome simplified controller, recessed in wall All £188.00 UK.BRC2E/BRA/POL Polished brass simplified controller, recessed in wall All £188.00 BRC3E52C Simplified remote controller (without heat/cool button) All £83.00 UK.BRC3E/CHR/POL Polished chrome simplified controller, recessed in wall (without heat/cool button) All £188.00 UK.BRC3E/CHR/BRU Brushed chrome simplified controller, recessed in wall (without heat/cool button) All £188.00 UK.BRC3E/BRA/POL Polished brass simplified controller, recessed in wall (without heat/cool button) All £188.00 BRP7A51/UK.FB2 Digital input adaptor for Key card and Window switch contacts with programmable logic For use with Simplified controllers £88.00 BRC4C61 Wireless remote controller FXKQ-MA £141.00 BRC4C62 Wireless remote controller FXDQ-M9 £141.00 BRC4C65 Wireless remote controller FXMQ-P7, FXLQ-P, FXNQ-A, FXDQ-A, FXSQ-A, FXMQ-MB £158.00 BRC7C58 Wireless remote controller FXUQ-A £158.00 BRC7C52 Wireless remote controller FXCQ-A £158.00 BRC7E618 Wireless remote controller FXAQ-P £141.00 BRC7F530W Wireless remote controller for White Ceiling Decoration Panel FXZQ-A + BYFQ60CW £158.00 BRC7F530S Wireless remote controller for Silver Ceiling Decoration Panel FXZQ-A + BYFQ60CS £158.00 BRC7EB530W Wireless remote for Fully Flat Cassette Old Style Decoration Panel FXZQ-A + BYFQ60B3 £158.00 BRC7FA532F Wireless remote controller FXFQ-A £158.00 BRC7G53 Wireless remote controller FXHQ-A £158.00 VRV Hard Wired Controllers Infra Red controllers 100 Residential, Commercial and Industrial VRV Accessories Control and BMS Interfaces (supplied separately) VRV Control and BMS Interfaces KRP4A53 RTD-NET RTD-10 RTD-20 RTD-HO KLIC-DI System Unit/Group Unit/Group Unit/Group Unit/Group Unit/Group Unit/Group System System System Control Protocol Daikin Daikin Modbus Modbus - Modbus Modbus KNX LONWorks BACnet Modbus 0-10 Volt control - - - - 4 4 - - - - - 4 4 - - 4 4 - - - - - On/Off 4 4 4 4 4 4 4 4 4 4 4 SetPoint Resistance control DMS504B51 DMS502A51 EKMBDXA VRV KRP2A52 Interface Method Control Functions 4 4 4 4 4 4 4 4 4 4 4 Operating Mode - - 4 4 4 4 4 4 4 4 4 Fan Speed - - 4 4 4 4 4 4 4 4 4 Louver Setting - - 4 4 4 4 4 4 - 4 4 VAM Damper control - - 4 4 4 4 - - - - - Control Prohibit / Restrict settings - - 4 4 4 4 4 - 4 4 4 Temperature SetPoint Limits - - 4 4 - 4 4 4 - - 4 Scene Creation - - - - - - - 4 - - - Monitoring Functions 4 4 4 4 - 4 4 4 4 4 4 Temperature Set Point - - 4 4 - 4 4 4 4 4 4 Operating Mode - - 4 4 - 4 4 4 4 4 4 Thermostat On - - 4 4 4 4 4 - 4 4 4 Fan Operation - - 4 4 - 4 4 4 4 4 4 Louvre Position - - 4 4 - 4 4 4 - 4 4 4 4 4 4 4 4 4 4 4 4 4 Fault Code - - 4 4 - 4 4 4 4 4 4 Remote Controller temperature - - 4 4 - 4 4 - 4 4 4 Remote Controller Mode - - 4 4 - 4 4 - - - - Number of Units - - 4 4 - 4 4 - - - - Return Air Temperature (Average/Min/Max) - - 4 4 - 4 4 - 4 4 - Coil In/Out temperature - - 4 4 - 4 4 - - - - Filter Alarm - - 4 4 - 4 4 4 4 4 4 Defrost Operation - - 4 4 4 4 4 - - - 4 Temperature Set Back - - - - - 4 4 - - - - Temperature Setpoint Limitation - - - 4 4 4 4 - - - - Key Card + Window Contact - - - - - 4 4 - - - - Heating Interlock - - - 4 4 - - - - - - Run / Standby - - - - 4 - - - - - - Interface KRP2A52 KRP4A53 RTD-NET RTD-10 RTD-20 RTD-HO KLIC-DI DMS504B51 DMS502A51 EKMBDXA Trade Price £184.00 £70.00 £172.00 £219.00 £236.00 £219.00 £193.00 £1,220.00 £3,924.00 £2,060.00 Mounting Box (FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ) UK.FB2 UK.FB2 UK.FB2 UK.FB2 UK.FB2 UK.FB2 - - - - Trade Price On/Off Fault Integral Functions (BMS system not req’d) Prices Associated Items £26.00 £26.00 £26.00 £26.00 £26.00 £26.00 - - - - Expansion PCB for additional unit connection - - - - - - - - DAM411B51 - Trade Price - - - - - - - - £915.00 Pulse input PCB for KWh meter input - - - - - - - - DAM412B51 - Trade Price - - - - - - - - £487.00 - Price List Update: Valid from 1st January 2017 101 VRV Accessories RTD-20 Control Panels Control Panels have been developed to allow easy installation of the RTD-20 into end-user premises. A typical application would require 1 RTD-20 per zone within a building. The control panels are pre-configured for up-to 8 different zones, making installation and wiring much simpler for the installer. VRV Model Description Trade Price RTD-20 Control Panels are sold at listed price. No discounts will apply. UK.RTD-20/ENCH Enclosure for RTD20 x 1 £318.00 UK.ENC/RTD-20X2 Enclosure for RTD-20 x 2 £797.00 UK.ENC/RTD-20X3 Enclosure for RTD-20 x 3 £1,052.00 UK.ENC/RTD-20X4 Enclosure for RTD-20 x 4 £1,307.00 UK.ENC/RTD-20X5 Enclosure for RTD-20 x 5 £1,640.00 UK.ENC/RTD-20X6 Enclosure for RTD-20 x 6 £1,900.00 UK.ENC/RTD-20X7 Enclosure for RTD-20 x 7 £2,155.00 UK.ENC/RTD-20X8 Enclosure for RTD-20 x 8 £2,410.00 Accessories for RTD-20 Control Panels Description Trade Price UK.RTD-EXTSEN Air Curtain External Sensor £21.00 UK.RTD-INTSEN Internal Sensor for RTD Device £13.00 UK.RTD-CABLE RS485 Cable for wiring RTD Devices 100m Roll £63.00 UK.RTD-PIR/7.5M PIR Sensor & 7.5M Cable Assy £56.00 UK.RTD-PIR/15.0M 7.5m Extension Cable for UK.RTD-PIR/7.5M £22.00 VRV Accessories Centralised Control Solutions Model 102 Description Trade Price DCS601C51 Intelligent touch controller for up to 64 fan coil units £1,707.00 KJB411A Recessed Fixing box for I-Touch controller £72.00 DCS302A52 Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager £108.00 DTA103A51 Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager £318.00 UK.IC Config I-Touch controller - off site configuration charge (please contact your sales office for info/prices) POA Residential, Commercial and Industrial Model Description Trade Price DCM601A51 I-Touch manager central touch screen controller, with integral web server and email function £2,353.00 DCM601A52 I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters £736.00 DCM002A51 Proportional Power Distribution add-on for I-Touch manager. Provides ability for tenant billing £1,832.00 DCM007A51 Open protocol software for BMS Integration £974.00 DCM008A51 Energy Navigator Software for I-Touch manager. For on screen energy monitoring £2,852.00 DCM009A51 BAC Net protocol for 3rd party products £1,252.00 DCS302A52 Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager £108.00 DTA103A51 Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager £318.00 WAGO Interface System Modular interface system for connection to 3rd Party devices such as lights, pumps, PIR sensors, access card readers, etc. Enables the iTM to control external devices and provide customised interlocks for automation and energy saving logic POA UK.IMAN/CONFIG1 I-Manager Off site configuration per FCU £7.00 UK.IMAN/CONFIG2 I-Manager Off site configuration & graphical layout per FCU. (Allow 4 weeks from order to delivery) £10.00 UK.FS1 On site commissioning for PPD or Energy Navigator Software £585.00 UK.IMAN/SITE TRAIN On Site customer training for I Touch Manager System £585.00 Price List Update: Valid from 1st January 2017 103 VRV VRV Accessories Centralised Control Solutions NEW VRV VRV Accessories Centralised Control Solutions Control of air conditioning within a retail environment produces its own set of challenges. The controls are often ‘hidden’ to prevent unauthorised access. This can result in equipment being left continuously operating, heating and cooling clashing and extremes of set point. Tabl e t Hardware Model Description Trade Price DCC601A51 Intelligent Tab Controller, with I/O module and power supply unit £614.00 Z380C Tablet for optional Wi-Fi based local control £255.00 4G-N12 Optional 3G router for Wi-Fi / web based control * £234.00 This can lead to user comfort complaints and excessive energy consumption. Frequently there is only one user who knows how to access the controls, and the maintenance company has no off site access to make adjustments. The solution to these issues is the Daikin Intelligent Tablet Controller. Features and benefits: > > > > > > > > Control of up to 32 indoor units (groups) Control of VRV, SkyAir, Splits, Air curtains & VAM units Intuitive local control via App based interface Control of all unit functions plus scheduling and set point restrictions integral to system Optional web based cloud control for off-site access Optional web based energy management software to automatically reduce wasted energy Optional multi-site control to facility benchmarking and permit control to be ‘pushed through’ to multiple sites in one operation Modular system – sites can be added to the controls package as they become available. Local solution *Supply of a suitable activated Sim and maintenance of the Sim contract is required by the installer. Service packages (annual fee) Description Trade Price ** Remote monitoring and control software for intelligent Tab Controller. Provides web access to intelligent Tab Controller. Energy performance software for intelligent Tab Controller. Provides energy saving control features. Multi-site management software for intelligent Tab Controller. Provides Benchmarking and Trending plus multi-site control. Business package software for LCC. Provides all features of Remote monitoring & control software, Energy performance software & Multi-site management software. POA ** First year subscription included in price of hardware. Annual renewal carried out on-line at listed price - not subject to discount. Online control from any device Alarm Window contact Daikin supplied screen (optional) (for local control) Z380C-1A023A Owner Pulse input or Digital input intelligent Tablet Controller wireless network Daikin supplied router (optional) 4G-N12 Installer/ technical manager Tabl et DCC601A51 Power supply CPU module Daikin network 104 Via internet or Via 3G/4G connection I/O module Split, , HRV, ventilation, air curtains Residential, Commercial and Industrial , From one to ∞ sites POA POA POA NEW VRV Accessories VRV & SkyAir Wi-Fi adapter Wi-Fi adapter VRV For use with VRV & SkyAir Features: Basic Operations > On/Off > Operation mode > Set point & room temperature > Fan speed > Air flow direction > Time clocking Wi-Fi adapter A delay off timer to automatically stop the air conditioning after a fixed number of hours run can be set. In addition multiple time clock schedules can be set. Both of these features can reduce energy wastage. Provide your customers with enhanced control of their air conditioning systems, with the Daikin Wi-Fi adapter and free downloadable App for smart phone or tablet. Occupied (Setback) and unoccupied (Home Leave) can be separately enabled to ensure minimum comfort levels are maintained when the property is empty. Benefits: In the event of an operational issue, the error & associated code will be displayed, to aid in the reinstatement of your system. Manually and automatically control the environment using your smart phone. Individual control of each room as well as control of the property as a whole is available via the group control function. From switching between heat and cooling, setting the required temperature and fan speed, setting minimum comfort levels and time clocking your air conditioning, the climate will be maintained to meet your requirements. An unlimited number of rooms and multiple properties can be controlled by a single account. > M ultiple users – Each user can be given their own account and allocated unit(s). Users can even share access to the same unit(s). > P hone not available – Control is also available via a dedicated web site using a web browser on your tablet or PC. *Broadband internet connection, Wi-Fi connection or Mobile data connection required. Indication of the ambient temperature and a weather forecast for the locale surrounding the property allow the user to adjust the system settings to meet their requirements. Model DKNWSERVER Description Wi-Fi adapter to connect to on-line server* One adapter required per fan coil unless group control of connected fan coils required, then one adapter per group Trade Price £197.00 *No annual charge is required to access this service. Price List Update: Valid from 1st January 2017 105 VRV Accessories Fan Coil Accessories (supplied separately) VRV Model Description Related Unit Trade Price BYCQ140DG Roundflow cassette decoration panel with self cleaning filter FXFQ-A £323.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres FXFQ-A £167.00 BYFQ60CS Fully Flat Cassette Decoration Panel - Silver FXZQ-A £206.00 BYFQ60B3 Fully Flat Cassette Decoration Panel - Old Style (FXZQ-MA style) [compatible with previous model FXZQ-M9] FXZQ-A £177.00 KDBHQ55B140 Sealing member for air discharge outlet FXFQ-A £94.00 BDBHQ44C60 Sealing member for air discharge outlet - Fully Flat cassette FXZQ-A £95.00 KDDP55C160-1 (suction chamber) KDDQ55B140-2 (connecting chamber) Fresh air intake kit for up to 20% fresh air (Not compatible with self-cleaning decoration panel) FXFQ-A £243.00 KDDQ50A140 Fresh air intake kit for up to 20% fresh air FXHQ-A £165.00 UK.RC1 1x200mm Return air spigot FXSQ 15 / 20 / 25 / 32 A £73.00 UK.RC2 2x200mm Return air spigot FXSQ 40 / 50 A £82.00 UK.RC3 2x200mm Return air spigot FXSQ 63 / 80 A £89.00 UK.RC3A 3x200mm Return air spigot FXSQ 63 / 80 A £97.00 UK.RC4 4x200mm Return air spigot FXSQ 100 / 125 A £121.00 UK.SF1 1x200mm Supply air spigot FXSQ 15 / 20 / 25 / 32 A £65.00 UK.SF2 2x200mm Supply air spigot FXSQ 40 / 50 A £75.00 UK.SF3 2x200mm Supply air spigot FXSQ 63 / 80 A £82.00 UK.SF3A 3x200mm Supply air spigot FXSQ 63 / 80 A £87.00 UK.SF4 4x200mm Supply air spigot FXSQ 100 / 125 A £108.00 UK.FF7/P Filter frame and filter FXMQ 100 to 125 £123.00 UK.FF8 Filter frame and filter FXMQ 200 to 250 £152.00 KRCS01-4 Remote room mounted temperature sensor FXFQ-A, FXZQ-A, FXQC-A, FXHQ-A, FXUQ-A, FXSQ-A, FXMQ-P7, FXDQ-A £42.00 KRCS01-1 Remote room mounted temperature sensor FXKQ-MA, FXDQ-P9, FXMQ-MA, FXAQ-P, FXLQ-P, FXNQ-P £48.00 K.RSS Wireless room mounted temperature sensor and receiver All £93.00 RS-SE Service and Configuration Tool for K.RSS All £97.00 Condensing Unit Accessories (supplied separately) Model Description Related Unit Trade Price BRP2A81 Adaptor PCB for Heat Cool selection terminals RYYQ-T £106.00 EBRP2B Adaptor PCB for Heat Cool selection terminals RXYSQ4-6TV1 £54.00 EKCHSC Adaptor Cable for Heat Cool selection terminals RXYSQ4-6TY1 £16.00 KJB111A Fixing box for EBRP2B & EKCHSC RXYSQ4-6T £17.00 KRC19-26 Cool/Heat selector switch for use with BRP2A81, EBRP2B or EKCHSC RYYQ-T, BS1Q-A & RXYSQ4-6T £33.00 EKPCCAB1 VRV Configurator Software Connection Cable. Software available from Daikin Extranet RYYQ-T, REYQ-T, RXYSQ-T & RXYSCQ-T £183.00 K.CGL Condensing Unit Guard size 100-140 including RXYSQ £369.00 Strip & Rebuild of Condensing Units VRV Condensing Units stripped down for delivery to site where lifting into position is difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers and fully retested. POA 106 Residential, Commercial and Industrial VRV Accessories VRV Refrigerant Leak Detection System Refrigerant leak detection systems can be required by the Safety of Building Occupants , BS-EN378. Daikin has a solution that can help meet requirements for leak detection within enclosed spaces. 1) The standard BS-EN378 requires that systems containing R410A refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert building staff such as supervisors, night porters etc. There is no specific requirement for the alarm system to be linked to the refrigerant system to pump down or stop the operation, although this can be configured if required by the client. 3 3 7 Not installed by door 7 7 7 Not installed near bathroom Not installed behind cupboards 7 Not installed near mirrors Refrigerant leak detector position It is recommended that guidance on the selection and installation of these systems is obtained from your local Daikin UK sales office. Model Not installed near windows Bed 150mm above floor level Description Related Unit Trade Price UK.RDEM-Wht White single gang room based refrigerant gas detector. C/W power supply unit and terminals for connection to alarm network or VRV fan coil to force system shut down All £288.00 UK.RDEM-Wht/ Curve Curved white single gang room based refrigerant gas detector. C/W power supply unit and terminals for connection to alarm network or VRV fan coil to force system shut down All £308.00 UK.RDEM-St/St Stainless steel single gang room based refrigerant gas detector. C/W power supply unit and terminals for connection to alarm network or VRV fan coil to force system shut down All £308.00 UK.IMEC-RAD-32 Network alarm hub for connection of up to 32 room alarms c/w web page configuration screen. Hub can be connected in a pyramid formation for connection to a central alarm indicator panel (UK.IAMC) All £1,846.00 UK.IMEC-RAD-64 Network alarm hub for connection of up to 64 room alarms c/w web page configuration screen. Hub can be connected in a pyramid formation for connection to a central alarm indicator panel (UK.IAMC) All £2,548.00 Description Related Unit Trade Price UK.IAM1 Room based refrigerant gas detector with remote room mounted stainless steel facia plate. Provides local audible and visual alarm notification. Terminals for connection to alarm network and optional connection to VRV Fan coil to force system shut down All £291.00 UK.IAM2 Network alarm hub for connection of up to 16 room alarms. Hub can be connected in a pyramid formation of 16 groups back to a single unit for connection to a central alarm indicator panel (UK.IAMC) All £572.00 UK.IAMC Alarm buzzer and lamp panel for mounting in a central building supervisor location All £404.00 Cross connection between the two different ranges of refrigerant leak detectors is not permissible. Model Price List Update: Valid from 1st January 2017 107 VRV Refrigerant Leak Detection Alarm VRV Accessories VRV Cloud Energy Assessment and Reporting VRV Cloud is Daikin’s unique energy usage assessment, optimisation, control and reporting tool. VRV System operational data can also be reported for a complete picture of system performance. Energy assessment Individual VRV system or whole site energy consumption can be accessed and viewed in a graphical form. The data can be viewed as an hourly, daily, monthly or annual graph. The energy consumption can be plotted against the outdoor air temperature or against a target consumption (which can be manually entered or automatically generated). Energy optimisation A target annual energy consumption limit can be set and the system will reduce operational output to meet the target. The target can either be manual set or automatically set via a simple slide bar – calibrated by user comfort level vs energy saving level. Control Access to the on-site touch screen controller is possible remotely. This gives the ability to change operational settings without having to attend site. Reporting Indoor and outdoor unit operational data can be viewed in tabular form. All data, energy usage and operational, can be extracted as a CSV file for incorporation within your own reports. Features and benefits: > > > > Unique Daikin automatic energy optimisation tool Graphical reporting of energy usage Remote access to site operational settings Reduction to energy consumption can be weighed vs user comfort > All data available for incorporation into your own reports. For more information, please contact your Daikin sales engineer. 108 Residential, Commercial and Industrial Daikin UK Price List Update VAM-FC 110 VKM-GB(M) 112 VENTILATION Ventilation For larger ventilation capacities from 2,000m3/hr to 15,000m3/hr see the new Daikin modular AHU on pages 190-192 of the Applied section. Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 Ventilation Achieving high indoor air quality for building occupants is an essential factor in HVAC design, especially in light of building regulations and the high levels of air tightness within modern buildings. VAM-FC Total Heat Exchanger Our popular range of Total Heat Exchangers (VAM) have been updated and are fully compliant with the new lot 6 Ecodesign requirements and rated under the EN 308* testing standard. VAM units recover waste energy from the exhaust airstream to minimise running costs and reduce the carbon footprint of the building. Daikin offers a range of options that enables control of fresh air into commercial and residential spaces. For flow rates of up to 0.556m3/s, our VAM / VKM range of heat recovery ventilation products can efficiently deliver controlled fresh air to meet your design priorities. For larger fresh air requirements, please see our Applied section for our range of packaged air handling units (See page 190-192 for our Modular AHU range). Eliminates up to 73% of the additional heating & cooling loads caused by introducing fresh air. VENTILATION VAM-FC Total Heat Exchanger VAM150FC Dimensions Height Width Depth mm mm mm Weight kg Duct Connection Diameter mm Air Flow Rate Ultra-High m3/hr High m3/hr Low m3/hr Ultra-High m3/sec High m3/sec Low m3/sec External Static Ultra-High Pa Pressure High Pa Low Pa Sound Pressure Ultra-High dBA Level (Heat High dBA Exchange Mode) Low dBA Electrical Details Power Supply V / Hz / Phase Running Current A Max Fuse Size A Trade Unit Price VAM250FC VAM350FC 285 776 525 24 VAM500FC 301 828 816 33 VAM650FC VAM800FC VAM1000FC VAM1500FC 364 1004 868 100 150 140 105 0.042 0.039 0.029 90 87 40 27 26 20.5 150 250 230 155 0.069 0.064 0.043 70 63 25 28.0 26.0 21.0 150 350 320 210 0.097 0.089 0.058 103 93 51 32.0 31.5 23.5 200 500 410 310 0.139 0.114 0.086 83 57 35 33.0 31.5 24.5 0.9 15 0.9 15 0.9 15 1.3 15 51 200 650 545 450 0.181 0.151 0.125 100 73 49 34.5 33.0 27.0 230 / 50 / 1 1.6 15 £448.00 £535.00 £709.00 £907.00 £1,110.00 VAM2000FC 726 1514 54 250 800 725 665 0.222 0.201 0.185 109 94 78 36.0 34.5 31.0 1160 63 250 1000 950 820 0.278 0.264 0.228 147 135 100 36.0 35.0 31.0 868 128 350 1500 1350 1230 0.417 0.375 0.342 116 97 80 39.5 38.0 34.0 1156 145 350 2000 1880 1500 0.556 0.522 0.417 132 118 77 40.0 38.0 35.0 2.5 15 3.0 15 5.0 15 5.0 15 £1,308.00 £1,499.00 £2,290.00 £2,986.00 VAM800FB VAM1000FB VAM1500FB VAM2000FB * For full details of specifications relating to EN308 please see the technical data book. * 2 power supplies required as 2 units bolted together. Optional Accessory Compatibility VAM150FA Inlet Heater Battery+ Air Filter VH1B - VAM250FA VAM350FB VAM500FB VH2B - VAM650FB VH3B EKAFV50F* EKAFV80F* VH4B or VH4/AB EKAFV100F* VH5B 2 x EKAFV100F* =+ Heater battery does NOT require PCB adaptor to connect to VAM * available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections. Optional Inlet Heater Battery Capacity Duct Diameter Trade Unit Price kW mm VH1B VH2B VH3B VH4B VH4/AB VH5B 1 100 £614.00 1 150 £620.00 1 200 £624.00 1.5 250 £676.00 2.5 250 £670.00 2.5 350 £676.00 Accessories: Accessory Ref Description Trade Price BRC1E53A KRP2A52/UK.FB2 RTD-Net/UK.FB2 RTD-20/UK.FB2 BRP4A50 KRP50-2 BRP4A50A EKAFV50F6 EKAFV50F7 EKAFV50F8 EKAFV80F6 EKAFV80F7 EKAFV80F8 EKAFV100F6 EKAFV100F7 EKAFV100F8 BRYMA65 BRYMA100 BRYMA200 Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock System adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Energy control PCB for Sky Air and VRV PCB Adaptor for VAM-A series connection to 3rd party heater PCB Adaptor for VAM-A series connection to humidifier PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier Air filter for VAM350 / 500FB : Medium M6 Air filter for VAM350 / 500FB : Fine F7 Air filter for VAM350 / 500FB : Fine F8 Air filter for VAM650 / 800FB : Medium M6 Air filter for VAM650 / 800FB : Fine F8 Air filter for VAM650 / 800FB : Fine F7 Air filter for VAM1000 / 2000FB : Medium M6 Air filter for VAM1000 / 2000FB : Fine F7 Air filter for VAM1000 / 2000FB : Fine F8 CO2 Sensor for VAM350 / 500 / 650 CO2 Sensor for VAM800 / 1000 CO2 Sensor for VAM1500 / 2000 £79.00 £211.00 £198.00 £262.00 £98.00 £111.00 £123.00 £53.00 £59.00 £64.00 £59.00 £64.00 £71.00 £90.00 £97.00 £102.00 £392.00 £392.00 £392.00 110 Residential, Commercial and Industrial CO2 sensors for VAM-FC range minimise running costs, delivering only the ventilation amounts required to maintain your indoor air quality Notes: i) Please contact your local sales office for required options when combined operation with an air conditioning system is required ii) Optional silencers and high efficiency filters are available. Prices and details on request iii) VKM models must be connected as the slave indoor unit of a standard VRV indoor unit and share the same BRC1D52 remote controller and BS-Q box (If connected to Heat Recovery) iv) UK.VH-CK VAM EHBX24 conversion kit cable included VAM-FC Weather Proof Enclosures for VAM Total Heat Exchangers If you need to install a VAM unit outside of a building then they need to be weatherproofed as they are designed for installation internally. We can offer fully weatherproofed housings for the VAM range which are rated IP46 to make them suitable for outdoor installation. The VAM units are fitted into the enclosure and delivered to site for fuss free installation. Please note: > T he prices quoted are for the enclosure, fitting of the VAM into the enclosure and standard delivery. The VAM unit cost is not included. VENTILATION > P re heaters cannot be used with the VAM weatherproof enclosures. Lead time: 6 weeks Applicable units: All VAM units (not VKM) UK.VAM250/ WPENC *Nett Enclosure Price (excluding VAM unit price) UK.VAM250/ WPENC UK.VAM250/ WPENC £812.00 UK.VAM250/ WPENC UK.VAM250/ WPENC UK.VAM250/ WPENC UK.VAM250/ WPENC UK.VAM250/ WPENC £936.00 £1,066.00 £1,144.00 * Not subject to standard trade discount. Please speak to your local sales engineer to discuss your requirements. Price List Update: Valid from 1st January 2017 111 VKM-GB(M) Total Heat Exchanger with DX Cooling & Heating (and Optional Humidifier) The Total Heat Exchanger removes additional fresh air loads by heating and cooling the air to suit the room setpoint. VKM units work with Daikin VRV indoor units to give a complete air conditioning solution by heating, cooling, cleansing, humidifying and distributing air within a space. Eliminates up to 100% of the additional heating & cooling loads caused by introducing fresh air Total Heat Exchanger with DX Coil (No Humidifier) VENTILATION Power input 50Hz Heat exchange mode Fresh air Cooling conditioning load Heating Dimensions Weight Temperature Exchange Efficiency Fan Air flow rate 50Hz External static pressure - 50Hz Sound pressure level 50Hz Heat exchange mode Duct connection diameter Piping Type connections Liquid Gas Drain Nom. Ultra high High Low Height x Width x Depth Ultra high / High Low Heat exchange mode Ultra high High Low Ultra high High Low Ultra high High Low Ultra high High Low OD OD kW kW kW kW kW mm kg % % m³/h m³/h m³/h m³/s m³/s m³/s Pa Pa Pa dBA dBA dBA mm VKM50GB VKM80GB VKM100GB 0.270 0.230 0.170 4.71 5.58 387 x 1764 x 832 96 76 77.5 500 500 440 0.139 0.139 0.122 0.330 0.280 0.192 7.46 8.79 0.410 0.365 0.230 9.12 10.69 387 x 1764 x 1214 109 78 79 750 750 640 0.208 0.208 0.178 210 170 140 39.0 37.0 35.0 200 160 110 41.1 39.0 37.0 36.5 250 Flare connection 1/4 (6.4) 1/2 (12.7) PT3/4 external thread Inch (mm) Inch (mm) Trade Unit Price 114 74 76.5 950 950 820 0.264 0.264 0.228 150 100 70 41.0 £2,173.00 £2,638.00 £3,137.00 VKM50GBM 0.270 0.230 0.170 4.71 5.58 VKM80GBM 0.330 0.280 0.192 7.46 8.79 Natural evaporating type 4.0 0.02 ~ 0.49 VKM100GBM 0.410 0.365 0.230 9.12 10.69 Total Heat Exchanger with DX Coil and Humidification Power input 50Hz Heat exchange mode Nom. Ultra high High Low Fresh air Cooling conditioning load Heating Humidifier System Amount Feed water pressure Elements Quantity Dimensions Height x Width x Depth Weight Temperature Exchange Efficiency Ultra high / High Low Fan Air flow rate Heat exchange Ultra high 50Hz mode High Low Ultra high High Low External static Ultra high pressure - 50Hz High Low Sound pressure Heat exchange Ultra high level 50Hz mode High Low Connection duct diameter Piping Type connections Liquid OD Gas OD Water supply Drain kW kW kW kW kW kg/h MPa 2.7 mm kg % % m³/h m³/h m³/h m³/s m³/s m³/s Pa Pa Pa dBA dBA dBA mm 387 x 1764 x 832 102 76 77.5 500 500 440 0.139 0.139 0.122 200 150 120 38.0 36.0 34.0 200 5.4 1 120 78 79 750 750 640 0.208 0.208 0.178 205 155 105 40.0 37.5 35.5 125 74 76.5 950 950 820 0.264 0.264 0.228 110 70 60 40.0 38.0 35.5 250 Flare connection 1/4 (6.4) 1/2 (12.7) 1/4 (6.4) PT3/4 external thread Inch (mm) Inch (mm) Inch (mm) Trade Unit Price 2 387 x 1764 x 1214 £2,417.00 £3,016.00 £3,375.00 Notes: i) Options for the VAM FC range are not compatible with the VKM G or VKM GM range 112 Residential, Commercial and Industrial ii) The humidifier in the VKM GM range operates solely in Heating mode and requires a third party humidistat to be connected Daikin UK Price List Update Commercial Heating 114 Altherma Flex Product Overview 114 Altherma Flex De-Centralised 115 Altherma Flex Centralised 116 Domestic Heating 118 Air-to-Water Heat Pump 119 Hybrid Heat Pump 133 Netatmo 138 Solar Thermal 139 Underfloor Heating 153 Heat Pump Convector 160 HEATING Heating As of the 26th September 2015 certain heating products are subject to the Energy Labelling Directive. Please go the following website to download your energy label. www.daikin.co.uk/energylabel Dedicated Heating Line: 0845 641 9070 Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 The Daikin Altherma Flex Heat Pump Series The Daikin Altherma Flex heat pump is ideal for apartment buildings and community heating, providing efficient air-to-water heat pump technology for large residential and commercial buildings. The product can be configured either as a de-centralised or a centralised system: HEATING De-centralised system The hydroboxes can be located in individual dwellings, such as apartments or collective housing, to create a de-centralised system. Each indoor unit can be operated independently, providing each property with individual control of heating, hot water (cooling optional on 50 & 80 class units). The indoor hydrobox units are fully equipped with all the required hydraulic components, so they can be connected easily to the heat distribution system. Individual dwellings can also be equipped with separate domestic hot water tanks, which are designed to stack on top of the indoor units. Centralised system Alternatively, the indoor units can be located together in one central plant area to create a centralised system suitable for a wide range of commercial and large domestic applications. The centralised indoor units offer modular system scalability and capacity to meet the heating demand of the overall building. 114 Residential, Commercial and Industrial Altherma Flex Communal Heat Pump De-Centralised Daikin Altherma Flex type is the first heating system for apartments and collective housing that fully incorporates the use of renewable energy sources, making large residential buildings more environmentally sustainable by increasing energy efficiency – thus delivering lower running costs and CO2 emissions. Altherma Flex Outdoor Units EMRQ Outdoor Units Capacity Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Seasonal space heating efficiency** Domestic hot water heating** Refrigerant Circuit Sound Pressure Piping Limits Piping Connections Nominal Heating Height x Width x Depth High Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating Space heating (Average climate) 55°C Average climate Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Discharge Gas EMRQ8A 22.4 EMRQ10A 28.0 3.167 78.4 331 3.167 78.4 amps amps amps amps Class Efficiency Class hwh Declared load profile 4 7.6 17.1 20 A+ 108 A 93 XL 4 9.9 22.1 25 A+ 104 A 93 XL kg kg dBA m m mm mm mm 10.3 10.6 58 58 9.52 15.9 19.1 100~260 5 £4,956.00 9.52 19.1 22.2 125~325 6 £5,200.00 kW mm kg m3/sec Pa Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price EMRQ12A 33.6 1680 x 1300 x 765 EMRQ14A 39.2 EMRQ16A 44.8 3.500 78.4 3-phase / 400V / 50Hz 4 12.6 22.3 25 A+ 103 A 93 XL R410A 10.8 Refer to Databook 60 100 40 12.7 19.1 28.6 150~390 7 £6,004.00 3.917 78.4 4.000 78.4 4 14.0 32.8 40 A+ 106 A 84 XL 4 16.9 33.0 40 A+ 103 A 93 XL 11.1 11.1 62 63 12.7 22.2 28.6 175~455 9 £7,079.00 12.7 22.2 28.6 200~520 10 £8,342.00 339 * Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio ** With 100% connection ratio combination Indoor Units (Hydrobox) Function Heating Capacity Cooling capacity Capacity Index Dimensions Empty Weight Leaving Water Temperature Range Leaving Water Temperature Range Drain valve Water Pump Expansion Vessel Material Colour Electrical Details kW kW Height x Width x Depth Heating Cooling mm kg °C °C Nominal ESP Heating kPa Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating Refrigerant Pipe Sizes Water Side Pipe Sizes Sound Pressure Level Refrigerant Trade Unit Price Hydro Box amps amps amps amps mm dBA EKHVMRD50AB EKHVMRD80AB EKHVMYD50AB EKHVMYD80AB Heating & Hot water Heating, hot water & cooling 5.6 9 5.6 9 n/a 5 8 50 80 50 80 705 x 600 x 695 92 120 25~80 n/a 5~20 Yes 83.7 58.8 7 litres heating 7 litres heating, 2 litres cooling Precoated sheet metal Metalic Grey 1-phase / 230V / 50Hz 4 6.5 10.9 6.5 10.9 16.5 20 12.7 Gas, 9.52 Liquid 12.7 Gas, 9.52 Liquid, 15.9 Suction 1" Female 40 42 40 42 R134a Cascade £2,579.00 £2,663.00 £3,167.00 £3,261.00 Hot Water Cylinders EKHTSU Accessories: Domestic hot water cylinder Type Max Water Temperature Height Width Depth Empty Weight Colour Material Inside Tank Material Outside Casing Piping Connections All Insulation Heat loss / 24 hour Δt 45°C Energy Efficiency Class Standing Heat Loss Storage Volume Trade Unit Price Accessories for hydrobox RTRNETA3AA (1) EKRP1AHT EKRP1HBA RTD-W UK.FB2 EKCC-W EKCLWS EKRUAHTB (2) EKBUHA6V3 (3) EKBUHA6W1 (3) EKFMAHTB K.FERNOXTF1 K.FERNOXTF1FL UK.FSHEAT/ COMMS (4) °C mm mm mm kg inch mm W L UK.EKHTSU200AC UK.EKHTSU260AC Unvented System (Includes EKUHWHT) 75 1335 1610 600 695 70 78 Metallic grey Stainless Steel Precoated sheet metal 3/4 " 80 1.2 1.5 B B 50 63 200 260 £1,158.00 £1,312.00 Notes: i) ii) iii) iv) Refnet joint prices can be found on page 97 Commissioning assistance should be included for each hydrobox DHW cylinder required for hot water function Supplied with 3 way valve and G3 safety kit (EKUHWHTB) i) ii) iii) iv) HEATING Altherma Flex Indoor Units EKHVMRD / EKHVMYD Hydrobox & cylinder shown in combination * Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio Description Trade price Netatmo thermostat for smartphone Optional PCB for demand control Optional PCB for remote alarm monitoring MODBUS interface for HT hydrobox Fixing box for RTD-W Sequence controller Additional thermistor for sequence controller Remote user interface In line back up heater 6kW, 1-phase, 230V In line back up heater 6kW, 3-phase, 400V Kit for cylinder standalone installation Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) Commissioning assistance per hydrobox 1 to 10 hydroboxes Commissioning assistance per hydrobox 11 to 20 hydroboxes Commissioning assistance per hydrobox >20 hydroboxes Daikin full commissioning £188.00 £108.00 £108.00 £214.00 £26.00 £666.00 £78.00 £164.00 £480.00 £480.00 £289.00 £97.00 £113.00 £240.00 £216.00 £192.00 POA RTRNETA3AA must be ordered alongside EKRP1AHT (1) EKRUAHTB: 1 included with each hydrobox (2) EKBUHA6V3(W1): Also requires EKRP1AHT (3) UK.FSHEAT/COMMS: Commissioning assistance should be included for each hydrobox (4) Price List Update: Valid from 1st January 2017 115 Altherma Flex Communal Heat Pump Centralised Daikin Altherma Flex type is the first centralised heating system for schools, public buildings , hotels, gyms & apartments that fully incorporates the use of renewable energy sources, making large buildings more environmentally sustainable by increasing energy efficiency – thus delivering lower running costs and CO2 emissions. Altherma Flex Outdoor Units EMRQ Outdoor Units Capacity Dimensions Weight Air Flow Rate External Static Pressure Electrical Details Seasonal space heating efficiency** Nominal Heating Height x Width x Depth High Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating Space heating (Average climate) 55°C Domestic hot water heating** Average climate Refrigerant Circuit Refrigerant Type Refrigerant Charge Additional Charge Sound Pressure Piping Limits Piping Connections Maximum Length Maximum Vertical Rise Liquid Discharge Gas EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A 22.4 28.0 33.6 1680 x 1300 x 765 39.2 44.8 190 78.4 331 190 78.4 235 78.4 240 78.4 amps amps amps amps Class Efficiency Class hwh Declared load profile 4 7.6 17.1 20 A+ 108 A 93 XL 4 9.9 22.1 25 A+ 104 A 93 XL 4 14.0 32.8 40 A+ 106 A 84 XL 4 16.9 33.0 40 A+ 103 A 93 XL kg kg dBA m m mm mm mm 10.3 10.6 11.1 11.1 58 58 62 63 9.52 15.9 19.1 100~260 5 9.52 19.1 22.2 125~325 6 210 78.4 3-phase / 400V / 50Hz 4 12.6 22.3 25 A+ 103 A 93 XL R410A 10.8 Refer to Databook 60 100 40 12.7 19.1 28.6 150~390 7 12.7 22.2 28.6 175~455 9 12.7 22.2 28.6 200~520 10 £4,956.00 £5,200.00 £6,004.00 £7,079.00 £8,342.00 kW mm kg m3/min Pa Capacity Index Limit Maximum Number of Connected Indoor Units HEATING Trade Condensing Unit Price 339 * Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio ** With 100% connection ratio combination Altherma Flex Indoor Units EKHBRD Indoor Unit (Hydrobox) Function Heating Capacity Cooling capacity Capacity Index Dimensions Empty Weight Leaving Water Temperature Range Drain valve Water Pump Expansion Vessel Material Colour Electrical Details kW kW Height x Width x Depth EKHBRD 011ADV1 EKHBRD 014ADV1 11 14 100 125 mm kg °C Heating Refrigerant Pipe Sizes Water Side Pipe Sizes Sound Pressure Level Refrigerant amps amps amps amps mm dBA Trade Unit Price Hydro Box EKHBRD 011ADY1 EKHBRD 014ADY1 EKHBRD 016ADY1 14 16 125 140 Heating & Hot water 16 11 n/a 140 100 705 x 600 x 695 145 148 25~80 Yes 92 Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating EKHBRD 016ADV1 11.6 22.5 88 85 92 12 litres Precoated sheet metal Metalic Grey 1-phase / 230V / 50Hz 4 15.1 23.8 25 18.1 23.8 4.3 12.5 88 3-phase / 400V / 50Hz 4 5.6 12.5 16 15.9 Gas, 9.52 Liquid 1” Female 46 43 R134a Cascade 43 45 £3,105.00 £3,160.00 £3,256.00 85 £3,167.00 6.7 12.5 45 46 £3,223.00 £3,320.00 * Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio Pre Selected Combinations Heating capacity (1) A7W35 kW 28.0 31.4 42.0 Heating capacity (2) A-3W65 kW 23.9 26.7 34.3 Outdoor unit Hydroboxes Demand PCBs Refnets Trade Price 1 x EMRQ8 2 x EKHBRD014ADV1 2 x EKRP1AHT 1 x KHRQ22M29T9 £11,529.00 £4,956.00 £6,320.00 £216.00 £37.00 1 x EMRQ10 2 x EKHBRD016ADV1 2 x EKRP1AHT 1 x KHRQ22M29T9 £5,200.00 £6,512.00 £216.00 £37.00 £11,965.00 (1) Heating ambient air temperature 7°C and leaving water temperature 35°C (2) Heating ambient air temperature -3°C and leaving water temperature 65°C, capacity stated net of 1 defrost cycle per hour Notes: i) Refnet joints can be found on page 97 ii) Commissioning assistance should be included per hydrobox 116 Residential, Commercial and Industrial iii) DHW cylinder required for hot water function iv) See page 115 for accessories 1 x EMRQ12 3 x EKHBRD014ADV1 3 x EKRP1AHT 1 x KHRQ22M64H £15,953.00 47.0 38.7 £6,004.00 £9,480.00 £324.00 £145.00 1 x EMRQ14 3 x EKHBRD016ADV1 3 x EKRP1AHT 1 x KHRQ22M64H £17,316.00 £7,079.00 £9,768.00 £324.00 £145.00 HEATING * Daikin Heating Systems HEATING As a leading heating supplier, Daikin’s product portfolio comprises a wide range of highly energy efficient renewable energy systems, providing the right heating solution for any application and requirement. Daikin Altherma air-to-water heat pump is a renewable energy heating and hot water solution, ideally suited for the UK housing market. Using renewable air as a heat source and heat pump technology with Daikin’s advanced inverter compressor technology, Daikin Altherma delivers high seasonal efficiencies, low running costs and reduced carbon emissions compared with traditional systems. Launched in 2006 with over 250,000 installed across Europe, Daikin Altherma is the leading air-to-water heat pump. Daikin Altherma offers the most comprehensive and flexible range of air-to-water heat pumps in the market today, suitable for houses, flats and both new build and refurbishment projects. The range is available in Low Temperature (Split and Monobloc) and High Temperature. Daikin Altherma High Temperature is an industry first system that can deliver water temperatures of up to 80°C, providing an ideal solution for boiler replacement in harder to treat properties. The majority of Daikin Altherma air-to-water heat pumps* are certified by the Microgeneration Certification Scheme (MCS) and the Daikin solar thermal collectors have Solar Keymark approval and therefore are eligible for the domestic RHI. Please check the MCS website for the latest list of accredited Daikin Altherma air-to-water heat pumps. Daikin is at the forefront of the drive for energy efficient heat pump technology, recognising that heat pumps and the use of renewable energy from the surrounding air is the answer to meet the future challenges of energy efficiency and carbon reduction targets. Daikin renewable energy solutions provide a real alternative to current and future problems associated with conventional heating systems such as increasing primary energy costs and unacceptably high environmental impact. Daikin solar thermal systems can be combined with Daikin Altherma to provide a fully integrated renewable energy solution. Daikin Altherma and Daikin solar thermal systems are recognised renewable energy solutions that can reduce hot water energy costs by up to 60% compared with traditional fossil fuel systems. * Except Daikin Altherma Flex Type 118 Residential, Commercial and Industrial MCS HP0006 011-7S1016 F MCS scheme Solar Keymark HEATING Air-to-Water Heat Pump Daikin Altherma air-to-water heat pump is available in the following models: Daikin Altherma Low Temperature Split 4-16kW Daikin Altherma Low Temperature Monobloc 5-16kW > Latest inverter technology, high seasonal efficiencies and low running costs > All key hydraulics built-in, e.g. expansion vessel and circulation pump > Guaranteed operation down to -25°C > Sealed refrigerant circuit with no F-gas needed for installation > Easy to use back lit controller > C ompact wall hung or floor standing integrated indoor unit with front access for easy maintenance > F lexible siting with indoor unit and small outdoor unit which can be sited up to 50m away Daikin Altherma High Temperature 11-16kW > Providing flow temperatures up to 80°C Daikin Altherma Flex Type 22.4-44.8kW * > For commercial heating applications * Except Daikin Altherma Flex Type Price List Update: Valid from 1st January 2017 119 Single Phase ERLQ-CV3 Low Temperature Split Heat Pump (outdoor) Outdoor Units Single Phase Description Trade Unit Price Dimensions Weight Nominal capacity Nominal input COP Seasonal space heating efficiency* Sound pressure / power level Refrigerant charge Piping connections Heating (a/b) Cooling Heating (a/b) Cooling Heating (a/b) Space heating (Average climate) 35°C Cooling Heating Cooling Hot water Heating Cooling R-410A Liquid Gas Max piping length OU to IU Power supply Recommended fuses HEATING ERLQ006CV3 ERLQ008CV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 4kW, 1-phase, 230V 6kW, 1-phase, 230V 8kW, 1-phase, 230V 11kW, 1-phase, 230V 14kW, 1-phase, 230V 16kW, 1-phase, 230V £2,753.00 £3,010.00 £1,128.00 Height x Width x Depth Space heating (Average climate) 55°C EER Operation range ERLQ004CV3 mm kg kW kW kW kW Class Efficiency SCOP Class Efficiency SCOP °C °C °C dBA dBA kg inches inches m £1,151.00 £1,541.00 £2,389.00 735 x 832 x 307 54 4.4 / 4.2 4.17 0.87 / 1.85 1.8 5.04 / 2.27 A++ 178 4.52 A++ 125 3.20 2.32 56 6.0 / 5.12 4.84 1.27 / 2.31 2.07 4.74 / 2.22 A++ 169 4.29 A++ 126 3.22 2.34 -25~25 10~43 -25~35 48 / 61 49 / 63 1.6 1/4 5/8 30 48 / 61 48 / 63 1.45 1345 x 900 x 320 56 7.4 / 6.13 5.36 1.66 / 2.89 2.34 4.45 / 2.12 A++ 171 4.34 A++ 126 3.22 2.29 11.2 / 9.6 11.72 2.43 / 4.57 4.31 4.60 / 2.1 A++ 156 3.98 A+ 120 3.09 2.72 49 / 62 50 / 63 1.6 51 / 64 50 / 64 113 14.5 / 10.8 12.55 3.37 / 5.19 5.08 4.30 / 2.08 A++ 153 3.90 A+ 123 3.16 2.47 -25~35 10~46 -20~35 51 / 64 52 / 66 3.4 3/8 5/8 50 16.0 / 10.9 13.12 3.76 / 5.22 5.73 4.25 / 2.09 A+ 149 3.80 A+ 119 3.06 2.29 52 / 66 54 / 69 1-phase / 230V / 50Hz A 20 40 Three Phase ERLQ-CW1 Low Temperature Split Heat Pump (outdoor) Outdoor Units 3 Phase Description Trade Unit Price Dimensions Weight Nominal capacity Nominal input COP Seasonal space heating efficiency* Height x Width x Depth Heating (a/b) Cooling Heating (a/b) Cooling Heating (a/b) Space heating (Average climate) 35°C Space heating (Average climate) 55°C EER Operation range Sound pressure / power level Refrigerant charge Piping connections Cooling Heating Cooling Hot water Heating Cooling R-410A Liquid Gas Max piping length OU to IU Power supply Recommended fuses mm kg kW kW kW kW Class Efficiency SCOP Class Efficiency SCOP °C °C °C dBA dBA kg inches inches m ERLQ011CW1 ERLQ014CW1 ERLQ016CW1 11kW, 3-phase, 400V 14kW, 3-phase, 400V 16kW, 3-phase, 400V £2,622.00 £3,023.00 1345 x 900 x 320 113 14.5 / 10.8 12.55 3.37 / 5.19 5.08 4.30 / 2.08 A++ 153 3.90 A+ 123 3.16 2.47 -25~35 10~46 -20~35 51 / 64 52 / 66 3.4 3/8 5/8 50 3-phase / 400V / 50Hz 20 £3,305.00 11.2 / 9.6 11.72 2.43 / 4.57 4.31 4.60 / 2.1 A++ 156 3.98 A+ 120 3.09 2.72 51 / 64 50 / 64 A 16.0 / 10.9 13.12 3.76 / 5.22 5.73 4.25 / 2.09 A+ 149 3.80 A+ 119 3.06 2.29 52 / 66 54 / 69 * When combined with matching indoor unit Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit Features: Notes: > This split system consists of an outdoor unit and an indoor hydrobox that can be connected to all standard low temperature radiators and underfloor heating systems > All models have extra features to withstand severe winter conditions i) Some units are available on special request with Blygold treatment to offer additional protection in coastal environments. Please contact your local sales office for further information 120 Residential, Commercial and Industrial Heating Only EHBH Low Temperature Split Hydrobox (wall hung) Indoor Unit (wall hung) Single Phase User interface (must be ordered) Description Combined Trade Unit Price Function Dimensions HxWxD Leaving water Heating temperature range Cooling Pump No. of speeds Expansion vessel volume Water connections Back-up heater 3kW 1ph 230V fuse rating 6kW 1ph 230V 6kW 3ph 400V 9kW 3ph 400V Single phase / 3 Phase* EHBH04CB3V EHBH08CB3V EHBH11CB3V EHBH16CB3V EHBH08CB9W EHBH11CB9W EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 For ERLQ004CV3 For ERLQ006008CV3 For ERLQ011CV3 For ERLQ014016CV3 For ERLQ006008CV3 For ERLQ011CV3/ W1 For ERLQ014016CV3/W1 £1,282.00 Heating Only £1,308.00 Heating Only £1,781.00 Heating Only £1,781.00 Heating Only 890 x 480 x 344 / 381 15 ~ 55 Inverter controlled 10 1 1/4” (female) 16 £1,320.00 Heating Only £1,901.00 Heating Only £1,901.00 Heating Only mm °C °C litres Inch A A A A - EHBH16CB9W 32** 10** 16** Heating and Cooling EHBX Indoor Unit (wall hung) Single Phase Single phase / 3 Phase* EHBX08CB3V EHBX11CB3V EHBX16CB3V EHBX08CB9W EHBX11CB9W User interface (must be ordered) EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 Drain pan kit (must be ordered) EKHBDPC2 EKHBDPC2 EKHBDPC2 EKHBDPC2 EKHBDPC2 EKHBDPC2 EKHBDPC2 For ERLQ004CV3 For ERLQ006008CV3 For ERLQ011CV3 For ERLQ014016CV3 For ERLQ006008CV3 For ERLQ011CV3/ W1 For ERLQ014016CV3/W1 £1,502.00 Reversible £1,533.00 Reversible £2,059.00 Reversible £2,059.00 Reversible 890 x 480 x 344 / 381 15 ~ 55 5 ~ 22 Inverter controlled 10 1 1/4” (female) 16 £1,550.00 Reversible £2,154.00 Reversible £2,154.00 Reversible Description Combined Trade Unit Price Function Dimensions Leaving water Heating temperature range Cooling Pump No. of speeds Expansion vessel volume Water connections Back-up heater 3kW 1ph 230V fuse rating 6kW 1ph 230V 6kW 3ph 400V 9kW 3ph 400V mm °C °C litres Inch A A A A - 32** 10** 16** Accessories: Notes: Accessory Ref Description Trade Price EKRUCBL2 EKRUCBS RTRNETA3AA EKPCCAB3 EKRSC1 KRCS01-1 EKRP1HBA User interface Optional simplified room thermostat Netatmo thermostat for smartphone PC cable – to upload field settings from PC to unit or spare controller Optional remote outdoor temperature sensor (cable not supplied) Optional remote indoor temperature sensor Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation U-beams to mount the outdoor units for ERLQ 004-008 Drainpan and U-beams for outdoor units ERLQ 004-008 Drainpan kit for indoor units EHBX 004-016 Heater mat for drainpan (EKDP008C) Pair of flexi feet to mount the outdoor unit Wall mounting bracket for outdoor units ERLQ 004-008 (90kg, 500mm long) Wall mounting bracket for outdoor units ERLQ 011-016 (140kg, 540mm long) Condensate drip tray for use with K.CWB90-2 Condensate drip tray for use with K.CWB140-2 Outdoor unit guard for ERLQ 004-008 Outdoor unit guard for ERLQ 011-016 Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £88.00 £83.00 £188.00 £188.00 £63.00 £48.00 £108.00 EKFT008CA EKDP008C EKHBDPC2 EKDPH008C K.FF600ASN K.CWB90-2 K.CWB140-2 K.DT1 K.DT2 K.CGM K.CGL K.FERNOXTF1 K.FERNOXTF1FL EHBX16CB9W HEATING EHBX04CB3V i) User interface (EKRUCBL2) must be ordered with every EHBH/X ii) * Back-up heater can be re-wired as 3kW/1ph, 6kW/1ph, 6kW/3ph or 9kW/3ph iii) ** 9W models only iv) Only one optional remote sensor can be installed. Sensor connects to indoor hydrobox £86.00 £121.00 £117.00 £183.00 £49.00 £37.00 £47.00 £56.00 £61.00 £308.00 £369.00 £97.00 £113.00 Features: > Available in heating only or heating/cooling versions > A choice of back-up heaters 3, 6 or 9kW > Heating / cooling hydroboxes must be ordered with drain pan kit Price List Update: Valid from 1st January 2017 121 HEATING NEW LT Integrated Hydrobox & DHW (floor standing) Daikin Altherma low temperature integrated hydrobox increases the quality and consistency of installations whilst decreasing the complexity and installation time thanks to the compact integration of all the indoor components in a single enclosure. Ideal for properties requiring domestic hot water the product is available with 180L or 260L capacities and compatible with the 4-16kW outdoor units. 180L Cylinder Part Number Description Trade Price UK.INTEGRA0418 4kW configuration for heating and hot water containing: £3,770.00 ERLQ004CV3 EHVH04SU18CB6W EKVSU180A EKRUCBL2 4kW outdoor unit 4kW indoor unit (heating only) with inbuilt 180L tank G3 Kit for 180L floor standing indoor unit User Interface £1,128.00 £2,357.00 £197.00 £88.00 UK.INTEGRA0618 6kW configuration for heating and hot water containing: £3,943.00 ERLQ006CV3 EHVH08SU18CB6W EKVSU180A EKRUCBL2 6kW outdoor unit 6kW equivalent indoor unit (heating only) with inbuilt 180L tank G3 Kit for 180L floor standing indoor unit User Interface £1,151.00 £2,507.00 £197.00 £88.00 UK.INTEGRA0818 8kW configuration for heating and hot water containing: £4,333.00 ERLQ008CV3 EHVH08SU18CB6W EKVSU180A EKRUCBL2 8kW outdoor unit 8kW indoor unit (heating only) with inbuilt 180L tank G3 Kit for 180L floor standing indoor unit User Interface £1,541.00 £2,507.00 £197.00 £88.00 Part Number Description HEATING 260L Cylinder Trade Price UK.INTEGRA0626 6kW configuration for heating and hot water containing: £4,100.00 ERLQ006CV3 EHVH08SU26CB6W EKVSU260A EKRUCBL2 6kW outdoor unit 6kW equivalent indoor unit (heating only) with inbuilt 260L tank G3 Kit for 260L floor standing indoor unit User Interface £1,151.00 £2,524.00 £337.00 £88.00 UK.INTEGRA0826 8kW configuration for heating and hot water containing: £4,490.00 ERLQ008CV3 EHVH08SU26CB6W EKVSU260A EKRUCBL2 8kW outdoor unit 8kW indoor unit (heating only) with inbuilt 260L tank G3 Kit for 260L floor standing indoor unit User Interface £1,541.00 £2,524.00 £337.00 £88.00 UK.INTEGRA1126 11kW configuration for heating and hot water containing: £5,792.00 ERLQ011CV3 EHVH11SU26CB6W EKVSU260A EKRUCBL2 11kW outdoor unit 11kW indoor unit (heating only) with inbuilt 260L tank G3 Kit for 260L floor standing indoor unit User Interface £2,389.00 £2,978.00 £337.00 £88.00 UK.INTEGRA1426 14kW configuration for heating and hot water containing: £6,156.00 ERLQ014CV3 EHVH16SU26CB6W EKVSU260A EKRUCBL2 14kW outdoor unit 14kW equivalent indoor unit (heating only) with inbuilt 260L tank G3 Kit for 260L floor standing indoor unit User Interface £2,753.00 £2,978.00 £337.00 £88.00 UK.INTEGRA1626 16kW configuration for heating and hot water containing: £6,413.00 ERLQ016CV3 EHVH16SU26CB6W EKVSU260A EKRUCBL2 16kW outdoor unit 16kW indoor unit (heating only) with inbuilt 260L tank G3 Kit for 260L floor standing indoor unit User Interface £3,010.00 £2,978.00 £337.00 £88.00 Price List Update: Valid from 1st January 2017 123 NEW Single Phase ERLQ-CV3 Low Temperature Split Heat Pump (outdoor) Outdoor Units Single Phase Description Trade Unit Price ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 4kW, 1-phase, 230V For EHVH04SU18CB6W 6kW, 1-phase, 230V For EHVH08SU18-26CB6W 8kW, 1-phase, 230V For EHVH08SU18-26CB6W 11kW, 1-phase, 230V For EHVH11SU26CB6W 14kW, 1-phase, 230V For EHVH16SU26CB6W 16kW, 1-phase, 230V For EHVH16SU26CB6W £1,151.00 £1,541.00 £2,389.00 £2,753.00 £3,010.00 £1,128.00 Dimensions Height x Width x Depth Weight Nominal capacity Heating (a/b) Cooling Heating (a/b) Cooling Heating (a/b) Space heating (Average climate) 35°C Nominal input COP Seasonal space heating efficiency* Space heating (Average climate) 55°C EER Operation range Sound pressure / power level Refrigerant charge Piping connections Cooling Heating Cooling Hot water Heating Cooling R-410A Liquid Gas Max piping length OU to IU Power supply Recommended fuses mm kg kW kW kW kW Class Efficiency SCOP Class Efficiency SCOP °C °C °C dBA dBA kg inches inches m V A 735 x 832 x 307 54 4.4 / 4.2 4.17 0.87 / 1.85 1.8 5.04 / 2.27 A++ 178 4.52 A++ 125 3.20 2.32 1345 x 900 x 320 56 6.0 / 5.12 4.84 1.27 / 2.31 2.07 4.74 / 2.22 A++ 169 4.29 A++ 126 3.22 2.34 -25~25 10~43 -25~35 48 / 61 49 / 63 1.6 1/4 5/8 30 48 / 61 48 / 63 1.45 56 7.4 / 6.13 5.36 1.66 / 2.89 2.34 4.45 / 2.12 A++ 171 4.34 A++ 126 3.23 2.29 11.2 / 9.6 11.72 2.43 / 4.57 4.31 4.60 / 2.1 A++ 156 3.98 A+ 120 3.09 2.72 49 / 62 50 / 63 1.6 51 / 64 50 / 64 113 14.5 / 10.8 12.55 3.37 / 5.19 5.08 4.30 / 2.08 A++ 153 3.90 A+ 123 3.16 2.47 -25~35 10~46 -20~35 51 / 64 52 / 66 3.4 3/8 5/8 50 16.0 / 10.9 13.12 3.76 / 5.22 5.73 4.25 / 2.09 A+ 149 3.80 A+ 119 3.06 2.29 52 / 66 54 / 69 1-phase / 230V / 50Hz 20 40 HEATING * When combined with matching indoor unit Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Sound pressure level measured at 1m from the unit NEW Single Phase EHVH-CB6W Low Temperature (indoor) Indoor Units Single Phase User interface (must be ordered) G3 Kit (must be ordered) Description Dimensions Weight Sound power level Sound pressure level Operating range Domestic hot water Hydraulic characteristics Power supply Back-up heater fuse rating 124 EHVH08SU18CB6W EHVH08SU26CB6W EHVH11SU26CB6W EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKRUCBL2 EKVSU180A EKVSU180A EKVSU260A EKVSU260A EKVSU260A For ERLQ011CV3 For ERLQ014-016CV3 £3,403.00 £3,403.00 For ERLQ004CV3 Combined Trade Unit Price Function Casing EHVH04SU18CB6W Colour Material Height x Width x Depth For ERLQ006-008CV3 £2,642.00 £2,792.00 £2,949.00 EHVH16SU26CB6W Heating only White Pre-coated sheet metal mm kg dBA dBA °C °C Nom. Nom. Space heating DHW Material Water volume l Tapping profile according to EN16147 ERP heat losses W ERP efficiency rating Standing losses @ 60°C kWh/24h Max operating pressure Bar Immersion heater kW Available back up heater kW Water connections DHW inch Water connections space heating inch V 3kW 1ph 230V A 6kW 1ph 230V A Residential, Commercial and Industrial 1,732 x 600 x 728 116 117 126 1,922 x 600 x 728 126 42 28 127 44 30 15°C-55°C 25°C-55°C Stainless steel (EN 1.4521) 180 L L L B C 58 B 1.4 10 2.5 6 G 3/4” (female) G 1”1/4 (female) 1-phase / 230V / 50Hz 16 32 260 L 80 C 1.9 L C Accessories: Notes: Accessory Ref Description Trade Price EKRUCBL2 EKRUCBS EKPCCAB3 RTRNETA3AA EKVSU180A EKVSU260A EKRSC1 KRCS01-1 EKRP1HBA Daikin Altherma user interface Daikin Altherma simplified room thermostat PC cable – to upload field settings from PC to unit Netatmo thermostat for smartphone G3 Kit for 180L floor standing indoor unit G3 kit for 260L floor standing indoor unit Optional remote temperature sensor for outdoor unit* Optional remote temperature sensor for indoor unit* Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation U-beams to mount the outdoor units for ERLQ 004-008 Drainpan and U-beams for outdoor units ERLQ 004-008 Drainpan kit for indoor units EHBX 004-016 Bottom plate heater for ERHQ 011-016 only Flexi-feet pair narrow Wall mounting bracket for outdoor units ERLQ 004-008 Wall mounting bracket for outdoor units ERLQ / ERHQ 011-016 Condensate drip tray for use with UK.CWB90-2 Condensate drip tray for use with UK.CWB140-2 Outdoor unit guard for ERLQ 004-008 Outdoor unit guard for ERLQ/ERHQ 011-016 Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £88.00 £83.00 £188.00 £188.00 £197.00 £337.00 £63.00 £48.00 £108.00 £86.00 £121.00 £117.00 £183.00 £49.00 £37.00 £47.00 £56.00 £61.00 £308.00 £369.00 £97.00 £113.00 HEATING EKFT008CA EKDP008C EKHBDPC2 EKDPH008C K.FF600ASN K.CWB90-2 K.CWB140-2 K.DT1 K.DT2 K.CGM K.CGL K.FERNOXTF1 K.FERNOXTF1FL i) * Only one optional remote sensor can be installed. Sensor connects to indoor hydrobox Price List Update: Valid from 1st January 2017 125 NEW EDLQ Standard Configurations Low Temperature Monobloc Heat Pump (5-7kW) Part Number Description Trade Price UK.MONO5 5kW base configuration for heating and hot water containing: £2,181.00 EDLQ05CV3 EKCB07CV3 EKRUCBL2 5kW outdoor unit (heating only) Wiring centre User interface £1,872.00 £221.00 £88.00 UK.MONO7 7kW base configuration for heating and hot water containing: £2,493.00 EDLQ07CV3 EKCB07CV3 EKRUCBL2 7kW outdoor unit (heating only) Wiring centre User interface £2,184.00 £221.00 £88.00 UK.MONO5GROUND 5kW ground mounted configuration for heating and hot water containing: £2,300.00 EDLQ05CV3 EKCB07CV3 EKRUCBL2 K.FF600ASN K.HOSE750 5kW outdoor unit (heating only) Wiring centre User interface Pair of flexi feet Pair of flexible hoses 750mm £1,872.00 £221.00 £88.00 £49.00 £70.00 7kW ground mounted configuration for heating and hot water containing: £2,612.00 7kW outdoor unit (heating only) Wiring centre User interface Pair of flexi feet Pair of flexible hoses 750mm £2,184.00 £221.00 £88.00 £49.00 £70.00 HEATING UK.MONO7GROUND EDLQ07CV3 EKCB07CV3 EKRUCBL2 K.FF600ASN K.HOSE750 126 Residential, Commercial and Industrial NEW EDLQ Low Temperature Monobloc Heat Pump (5-7kW) Outdoor Unit EDLQ05CV3 User Interface (must be ordered) Description Combined Trade Unit Price Dimensions Weight Capacity Input COP Seasonal space heating efficiency EKRUCBL2 5kW, 1-phase, 230V 7kW, 1-phase, 230V £1,960.00 Height x Width x Depth Heating (a/b) Heating (a/b) Space heating (Average climate) 35°C Space heating (Average climate) 55°C Operation Range EDLQ07CV3 EKRUCBL2 Heating Hot Water Sound pressure/Power level Refrigerant charge R-410A Power supply Recommended Fuses Pump No. of speeds Expansion vessel volume Water connections Diameter Max piping length OU to cylinder mm kg kW kW Class Efficiency SCOP Class Efficiency SCOP °C °C dBA kg £2,272.00 735 × 1085 × 350 76 4.40 / 4.20 0.88 / 1.95 5.00 / 2.15 A++ 172 4.39 A++ 125 3.20 80 7.00 / 6.25 1.55 / 3.09 4.52 / 2.02 A++ 163 4.14 A++ 126 3.22 -25 ~ +25 -25 ~ +35 48 / 61 1.30 49 / 62 1.45 1-phase / 230V / 50Hz Amps 16 20 Inverter Controlled 7 1” (male) 10 litres Inch mm Nominal capacity and nominal input tested according to EN 14511 at the following conditions Heating a: Ambient air temperature 7C and leaving water temperature 35C (A7 W35) Heating b: Ambient air temperature -7C and leaving water temperature 45C (A-7 W45) Sound pressure level measured at 1m from the unit WIRING CENTRE Wiring centre £221.00 Depth Width Height mm mm mm BACK UP HEATER KIT (OPTIONAL) Description Trade Unit Price Power supply Recommended fuses Water connections Depth Width Height kW mm mm mm 3 kW 1ph 230V 6 kW 1ph 230V Diameter Amps Amps inch HEATING Trade Unit Price Nominal rating Dimensions i) User interface (EKRUCBL2) must be ordered with every EDLQ05-07 EKCB07CV3 Description To use with Dimensions Notes: EDLQ05~07CV3 97 340 360 EKMBUHC3V3 EKMBUHC9W1 Back up heater kit (3kW) Back up heater kit (3/6kW) £454.00 £505.00 3 3-6 210 250 560 1-phase / 230V / 50Hz 1-phase / 230V / 50Hz 16 - 32 1” (male) Accessories: Accessory Ref Description Trade Price EKRUCBL2 EKRUCBS RTRNETA3AA EKPCCAB3 EKRSC1 KRCS01-1 EK2CB07CV3 K.FF600ASN K.CWBXL K.DT2 K.HOSE750 K.HOSE750EL User interface Optional simplified room thermostat Netatmo thermostat for smartphone PC cable – to upload field settings from PC to unit or spare controller Optional remote outdoor temperature sensor (see note) Optional remote indoor temperature sensor (see note) Optional Wiring centre - for remote alarm monitoring, run and fault indication and bivalent operation Pair of flexi feet to mount the outdoor unit Wall mounting brackets for outdoor units (250kg, 660mm long) Condensate drip tray for use with K.CWBXL Pair of flexible hoses (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression) Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression) Outdoor unit guard Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £88.00 £83.00 £188.00 £188.00 £63.00 £48.00 £221.00 £49.00 £71.00 £61.00 £70.00 £101.00 K.CG750S K.FERNOXTF1 K.FERNOXTF1FL £286.00 £97.00 £113.00 Notes: i) Only one optional remote sensor can be installed Features: > The small Daikin Altherma Monobloc is ideal for smaller properties > In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary > The optional back-up heater is installed indoors Price List Update: Valid from 1st January 2017 127 Heating Only EDHQ Low Temperature Monobloc Heat Pump (14-16kW) Outdoor Unit Single Phase Description Trade Unit Price Function Dimensions Height x Width x Depth Weight Nominal input EDHQ014BB6W1 EDHQ016BB6W1 14kW, 1-phase, 230V 16kW, 1-phase, 230V 14kW, 3-phase, 400V 16kW, 3-phase, 400V £2,954.00 £3,339.00 £3,120.00 £3,536.00 Heating Only Heating Only Heating Only Heating Only mm Heating (a/b) kW Cooling kW Heating (a/b) kW Cooling kW COP Heating (a/b) Seasonal space heating efficiency Space heating (Average climate) 35°C Space heating (Average climate) 55°C EER 1418 x 1435 x 382 1418 x 1435 x 382 180 14 / 7.72 180 16 / 8.7 14 / 7.72 16 / 8.7 3.29 / 3.76 3.88 / 4.44 3.31 / 3.84 3.81 / 4.39 - - 4.25 / 2.05 4.12 / 1.96 4.23 / 2.01 Class A+ A+ A+ A+ Efficiency 130 123 130 127 SCOP 3.32 3.15 3.31 3.25 Class A+ A+ A+ A+ Efficiency 105 101 110 111 SCOP 2.71 2.6 2.82 Cooling Operation range 4.2 / 1.98 2.85 - -15~35 Heating °C -15~35 Cooling °C - - Hot water °C -15~35 -15~35 Sound pressure / power level Heating dBA Cooling dBA Refrigerant charge (factory) R-410A Back up heater (factory fitted) Recommended fuses Pump 51 / 65 52 / 66 51 / 65 53 / 66 - - kg 2.95 2.95 kW 6 6 1-phase / 230V / 50Hz 3-phase / 400V / 50Hz Power supply HEATING EDHQ016BB6V3 kg Nominal capacity 3 Phase EDHQ014BB6V3 Outdoor unit A 32 20 6kW BUH A 32 20 No. of speeds Expansion vessel volume 2 2 10 10 1 ¼ (female) 1 ¼ (female) 10 10 litres Water connections (diameter) inches Max piping length OU to cylinder m Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit Accessories: Notes: Accessory Ref Description Trade Price EKBPHTH16A EKRP1HBA Bottom plate heater for outdoor units sizes 014-016 (see note) Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation Netatmo thermostat for smartphone Optional wired room thermostatic controller Optional wireless room thermostatic controller Floor temperature sensor for use with wireless room thermostat EKRTR Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £137.00 £108.00 RTRNETA3AA EKRTWA EKRTR EKRTETS K.FERNOXTF1 K.FERNOXTF1FL £188.00 £103.00 £202.00 £14.00 £97.00 £113.00 Features: > The Daikin Altherma Monobloc contains all components and the back-up heater in the outdoor unit > In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary for installation 128 Residential, Commercial and Industrial i) It is strongly recommended to install the bottom plate heater in units that will be installed in a region that will experience prolonged periods below 0°C with very high humidity ii) Every unit is supplied with a controller Heating and Cooling EBHQ Low Temperature Monobloc Heat Pump (14-16kW) Outdoor Unit Single Phase 3 Phase EBHQ014BB6V3 EBHQ016BB6V3 EBHQ014BB6W1 EBHQ016BB6W1 14kW, 1-phase, 230V 16kW, 1-phase, 230V 14kW, 3-phase, 400V 16kW, 3-phase, 400V Trade Unit Price £3,068.00 £3,464.00 £3,235.00 £3,656.00 Function Reversible Reversible Reversible Description mm Heating (a/b) kW 14 / 7.72 16 / 8.7 14 / 7.72 Cooling kW 12.5 13.1 12.5 13.1 Heating (a/b) kW 3.29 / 3.76 3.88 / 4.44 3.3 / 3.84 3.81 / 4.39 Cooling kW Weight Nominal capacity Nominal input 1418 x 1435 x 382 kg COP Heating (a/b) Seasonal space heating efficiency Space heating (Average climate) 35°C Space heating (Average climate) 55°C EER Cooling Operation range Heating 1418 x 1435 x 382 180 180 5.39 5.93 5.06 5.75 4.12 / 1.96 4.23 / 2.01 4.2 / 1.98 Class A+ A+ A+ A+ Efficiency 130 123 130 127 SCOP 3.32 3.15 3.31 3.25 Class A+ A+ A+ A+ Efficiency 105 101 110 111 SCOP 2.71 2.6 2.82 2.85 2.32 2.21 2.47 °C 2.28 -15~35 -15~35 Cooling °C 10~46 10~46 Hot water °C -15~35 -15~35 Heating dBA 51 / 65 52 / 66 51 / 65 Cooling dBA 52 / 66 54 / 69 52 / 66 Refrigerant charge (factory) R-410A kg Back up heater (factory fitted) 53 / 66 54 / 69 2.95 kW Power supply Pump 16 / 8.7 4.25 / 2.05 Sound pressure / power level Recommended fuses Reversible Height x Width x Depth 2.95 6 6 1-phase / 230V / 50Hz 3-phase / 400V / 50Hz Outdoor unit A 32 20 6kW BUH A 32 20 No. of speeds Expansion vessel volume 2 2 10 10 1 ¼ (female) 1 ¼ (female) 10 10 litres Water connections (diameter) inches Max piping length OU to cylinder m HEATING Dimensions Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit EKHWSU Hot Water Cylinder for Low Temperature Split and Monobloc Domestic hot water cylinder Description Trade Unit Price Suitable for Energy efficiency class Standing heat loss (ErP) Storage volume Standing heat loss Max water temperature Booster heater capacity Power supply Recommended fuses Height Diameter Empty weight Material inside cylinder Piping connections (diameter) W L kWh/24h °C kW A mm mm kg Water inlet H/E Water outlet H/E Cold water in Hot water out inch inch inch inch UK.EKHWSU150B3V3 UK.EKHWSU200B3V3 UK.EKHWSU300B3V3 150L unvented cylinder (Including EKUHWBB) 200L unvented cylinder (Including EKUHWBB) 300L unvented cylinder (Including EKUHWBB) £1,107.00 £1,125.00 Unvented systems (EKUHWBB kit included) C 74 200 1.77 85 3 1-phase / 230V / 50Hz 16 1265 580 46 Stainless steel 3/4 (female) 3/4 (female) 3/4 (female) 3/4 (female) £1,236.00 C 65 150 1.55 1015 38 C 91 285 2.19 1715 60 Features: > This stainless steel unvented cylinder is the ideal partner for Daikin Altherma Low Temperature Split and Monobloc heat pumps > Fitted with 3kW immersion heater as standard > Supplied with 3-way valve and G3 safety kit (EKUHWBB) > For vented hot water cylinders, please contact your local sales office Price List Update: Valid from 1st January 2017 129 ERSQ High Temperature Split Heat Pump (outdoor) Outdoor Unit Single Phase Description Trade Unit Price Dimensions 3 Phase ERSQ011AV1 ERSQ014AV1 ERSQ016AV1 ERSQ011AY1 ERSQ014AY1 ERSQ016AY1 11kW, 1-phase, 230V 14kW, 1-phase, 230V 16kW, 1-phase, 230V 11kW, 3-phase, 400V 14kW, 3-phase, 400V 16kW, 3-phase, 400V £2,571.00 £2,901.00 1345 x 900 x 320 £3,134.00 £2,807.00 £2,945.00 1345 x 900 x 320 £3,479.00 Height x Width x Depth mm Nominal capacity Heating (a/b) kW 11 / 11 14 / 14 16 / 16 11 / 11 14 / 14 16 / 16 Nominal input Heating (a/b) kW 3.03 / 3.57 4.07 / 4.66 4.83 / 5.57 3.03 / 3.57 4.07 / 4.66 4.83 / 5.57 COP Heating (a/b) 3.63 / 3.08 3.44 / 3.00 3.31 / 2.88 3.63 / 3.08 3.44 / 3.00 3.31 / 2.88 Seasonal space heating efficiency* Space heating (Average climate) 35°C B B B B B B Efficiency 105 110 112 105 110 112 2.88 Weight kg Class 120 120 SCOP 2.7 2.68 2.88 2.7 2.68 Space heating (Average climate) 55°C Class A+ A+ A+ A+ A+ A+ Efficiency 103 104 102 103 104 102 SCOP 2.65 2.66 2.61 2.65 2.66 2.61 Operation range Heating °C Hot water °C Sound pressure / power level Refrigerant charge Heating R-410A dBA kg Piping connections -20 ~ + 24 -20 ~ + 24 -20 ~ + 35 52 / 68 53 / 69 4.5 -20 ~ + 35 55 / 71 52 / 68 53 / 69 4.5 Liquid inches 3/8 3/8 Gas inches 5/8 5/8 Max piping length OU to IU m Power supply Recommended fuses 50 50 1-phase / 230V / 50Hz 3-phase / 400V / 50Hz 25 16 A * When combined with matching indoor unit Nominal capacity and nominal input tested at the following conditions: a. A7 W45 according to EN14511 55 / 71 b. A7 W65 according to Eurovent rating standard 6/C/003-2006 Features: HEATING > The outdoor unit extracts heat from the ambient air and transfers it to the indoor unit via refrigerant piping > Heating only versions > Order with matching indoor unit EKHBRD High Temperature Split Hydrobox (floor standing) Indoor Unit (floor standing) Single Phase 3 Phase EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1 Description 11kW, 1-phase, 230V Trade Unit Price To use with Dimensions Height x Width x Depth Weight Leaving water temperature range Refrigerant charge (factory) R134a Power supply Recommended fuses Pump No. of speeds Expansion vessel volume Water connections (diameter) 14kW, 1-phase, 230V 16kW, 1-phase, 230V £3,105.00 ERSQ011AV1 mm kg °C kg A litres inch £3,160.00 £3,256.00 ERSQ014AV1 ERSQ016AV1 705 x 600 x 695 144.25 25~80 without electrical heater 3.2 1-phase / 230V / 50Hz 25 Inverter controlled 12 1 (female) 11kW, 3-phase, 400V 14kW, 3-phase, 400V 16kW, 3-phase, 400V £3,167.00 ERSQ011AY1 £3,223.00 £3,320.00 ERSQ014AY1 ERSQ016AY1 705 x 600 x 695 147.25 25~80 without electrical heater 3.2 3-phase / 400V / 50Hz 16 Inverter controlled 12 1 (female) Features: > T he indoor unit receives the heat from the outdoor unit and further increases the temperature up to 80°C, which is ideal for use with existing radiators > It is designed to only be used with the integrated hot water cylinder EKHTSU > For RHI, check maximum design flow temperature carefully Accessories: Accessory Ref RTRNETA3AA EKBPHTH16A EKBUHA6V3 EKBUHA6W1 EKRP1AHT EKRUAHTB EKRP1HBA EKRTWA EKRTR EKRTETS RTD-W K.CWB140-2 K.DT2 K.CGL K.FF600ASN K.FERNOXTF1 K.FERNOXTF1FL 130 Notes: Description Netatmo thermostat for smartphone (also requires EKRP1AHT) Bottom plate heater for outdoor unit sizes 011-016 In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*) Remote user interface Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump Optional wired room thermostatic controller (also requires EKRP1AHT) Optional wireless room thermostatic controller (also requires EKRP1AHT) Floor temperature sensor for use with EKRTR (also requires EKRP1AHT) MODBUS interface for HT hydrobox Wall mounting bracket for outdoor unit ERSQ 011-016 Condensate drip tray for use with K.CWB140-2 Outdoor unit guard for ERSQ 011-016 Pair of flexi feet to mount the outdoor unit Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) Residential, Commercial and Industrial Trade Price £188.00 £137.00 £480.00 £480.00 £108.00 £164.00 £108.00 £103.00 £202.00 £14.00 £214.00 £47.00 £61.00 £369.00 £49.00 £97.00 £113.00 i) Needs to be ordered with EKRP1AHT EKHTSU Hot Water Cylinder for High Temperature Split Domestic hot water cylinder Description Trade Unit Price Suitable for Energy efficiency class Standing heat loss (ErP) Storage volume Max water temperature Standing heat loss Dimensions (cylinder only) Dimensions (cylinder integrated on hydrobox) Empty weight Material inside cylinder Piping connections (diameter) UK.EKHTSU200AC UK.EKHTSU260AC 200L unvented cylinder 260L unvented cylinder £1,158.00 £1,312.00 Unvented systems (including EKUHWHTB) Height x Width x Depth Height x Width x Depth W L °C kWh/24h mm mm kg Water inlet H/E Water outlet H/E Cold water in Hot water out mm mm inch inch B 50 200 B 63 260 75 1.2 1335 x 600 x 695 2010 x 600 x 695 1.5 1610 x 600 x 695 2285 x 600 x 695 70 78 Stainless steel 25 (female quick coupling, supplied, integrated solution) 25 (female quick coupling, supplied, integrated solution) 3/4 (female) 3/4 (female) Accessories: Accessory Ref Description Trade Price EKFMAHTB Kit for standalone installation with floor standing hydrobox £289.00 Features: HEATING > This integrated cylinder is designed for use with Daikin Altherma HT only > The cylinder features fast heat-up and recovery times, and low heat losses > The indoor unit and hot water cylinder are designed to be stacked to save space, or can alternatively be installed next to each other if limited height is available for installation (please order EKFMAHTB) > Supplied with 3-way valve and G3 safety kit (EKUHWHTB) Price List Update: Valid from 1st January 2017 131 Air-to-Water Heat Pump Combination Table Daikin have a full range of air-to-water heat pumps to suit many installation requirements and applications. Use the table below to help select the right combination of equipment. LT Split 4-16kW Outdoor Indoor DHW cylinder or Thermal store or ERLQ004-008 (page 120) EHBH/X04-16 ERLQ011-016 (page 121) LT Monobloc 5-7kW LT Monobloc 14-16kW UK.EKHWSU150-300B or Wiring centre EKCB (page 127) EDLQ05-07 (page 127) Back-up heater (optional) EKMBUH UK.EKHWSU150-300B (page 127) (page 129) EKHWP300-500(P)B or EDHQ/EBHQ014-016 UK.EKHWSU150-300B (page 128 - 129) 132 EKHWP300-500(P)B (page 129) EKHWP300-500(P)B (page 129) HT Split 11-16kW HEATING (page 120) or ERSQ011-016 EKHBRD011-016 UK.EKHTSU200-260AC (page 130) (page 130) (page 131) Residential, Commercial and Industrial EKHWP300-500(P)B Hybrid Heat Pump The Daikin Altherma Hybrid Heat Pump is unique technology. It combines a high efficiency gas combi boiler with a renewable energy air-to-water heat pump, all in one efficient, compact heating system. Daikin Altherma Hybrid heat pump The smart hybrid logic automatically selects the most energy efficient and cost-effective operation based on the user’s energy tariff, at any given temperature to make it the most efficient solution on the market. > S imple easy to use backlit control using energy tariffs for automatic control > S uitable for heating systems requiring flow temperatures up to 80°C > Heat pump capacity: 5 and 8kW > E ligible for RHI when fitted with required heat and electric meters > Single compact indoor unit to minimise space > No DHW tank needed – hot water delivered by combi boiler > A ll key components built in: A-label pump, expansion vessel, pressure relief > B oiler output CH 27kW (80/60) and DHW 33kW (13 l/min at ΔT 35K) > Boiler SEDBUK (2009) rated 89.1% (natural gas) and 90.1% (LPG) > Dedicated training courses available HEATING > S uitable for LPG applications for even higher running cost savings Price List Update: Valid from 1st January 2017 133 EVLQ / EHYHBH / EHYKOMB Daikin Altherma Hybrid Heat Pump System Outdoor Units Dimensions Weight Nominal capacity Nominal input COP Seasonal space heating efficiency* EVLQ05CV3 Height x Width x Depth Heating Heating Heating Space heating (Average climate) 55°C Domestic hot water heating* Average climate Operation range (ambient) Sound pressure / power level Refrigerant charge Piping connections Heating Heating R-410A Liquid Gas Max piping length OU to IU Power supply Recommended fuses mm kg kW kW Class Efficiency SCOP Class hwh Declared load profile °C dBA kg inches inches m EVLQ08CV3 735 x 832 x 307 54 4.4 0.87 5.04 A++ 128 3.28 A 95 XL 56 7.4 1.66 4.45 A++ 127 3.24 A 95 XL -25~25 48 / 61 1.45 49 / 62 1.6 1/4 5/8 20 1-phase / 230V / 50Hz 20 A * When combined with matching indoor unit Indoor Unit and boiler wall hung (1 combined unit) HEATING Indoor Unit (heat pump) Function To use with Dimensions Weight Leaving water temperature range Pump Expansion vessel volume Indoor Unit (boiler) Height x Width x Depth Heating mm kg °C No. of speeds litres Function To use with Dimensions Max dimensions (boiler and heat pump) Weight Capacity (heating) Capacity (hot water) Leaving water temperature range DHW flow rate ΔT 35K Heating connections DHW connections Gas connection IP rating Device type Supply pressure Nox class Flue gas connection Maximum flue length, 60/100 Maximum flue length, 80/125 SEDBUK rating (2009) Height x Width x Depth Height x Width x Depth mm mm Minimum Maximum Minimum Maximum Heating Hot water Hot water Diameter Diameter Diameter kg kW kW kW kW °C °C l/min mm mm mm Natural gas (G20) LPG (G31) mbar mbar m m % Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Sound pressure level measured at 1m from the unit 134 Residential, Commercial and Industrial EHYHBH05AV32 EHYHBH08AV32 Heating Only EVLQ05CV3 Heating Only EVLQ08CV3 1075 x 450 x 164 30 31.2 25~55 Inverter controlled 10 EHYKOMB33AA2 Heating only EHYHBH05AV32 EHYHBH08AV32 710 x 450 x 240 1075 x 450 x 405 36 7.6 27 7.6 32.7 15 ~ 80 40 ~ 65 13.1 22 15 15 IP44 C13, C33 20 30-37 5 60/100 10 29 89.1 (NG) / 90.1 (LPG) EVLQ / EHYHBH / EHYKOMB Daikin Altherma Hybrid Heat Pump System Part Number Description Trade Price UK.HYBRID05B33 Hybrid 5kW pack £3,533.00 EVLQ05CV3 EHYHBH05AV32 EHYKOMB33AA2 EKRUCBL2 EKHY093467 EKVK3A Outdoor unit: 5kW, 1-phase, 230V Hydrobox: 5kW, 1-phase, 230V Hybrid combi boiler: 33/27kW User interface Pipe cover plate Hybrid valve pack £1,128.00 £1,220.00 £1,030.00 £88.00 £20.00 £47.00 Hybrid 8kW pack £4,002.00 This pack contains: UK.HYBRID08B33 This pack contains: EVLQ08CV3 EHYHBH08AV32 EHYKOMB33AA2 EKRUCBL2 EKHY093467 EKVK3A Outdoor unit: 8kW, 1-phase, 230V Hydrobox: 8kW, 1-phase, 230V Hybrid combi boiler: 33/27kW User interface Pipe cover plate Hybrid valve pack £1,541.00 £1,276.00 £1,030.00 £88.00 £20.00 £47.00 Accessories: Accessory Ref Description Trade Price K.HEATMET Heat meter for domestic RHI (for Altherma hybrid only) Class 3 heat meter delivered with body, digital interface and 2 temperature sensors Electric meter for RHI (single phase) IEC Class 1 electric meter to measure the electricity consumption of the Daikin Altherma heat pump LPG conversion kit Flue adapter 80/125 PC cable – to upload field settings from PC to unit or spare controller Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock Optional simplified room thermostat Netatmo thermostat for smartphone Optional remote temperature sensor for outdoor temperature (see note) Optional remote temperature sensor for indoor temperature (see note) U-beams to mount the outdoor unit EVLQ05CV3 Drainpan and U-beams for outdoor unit EVLQ05CV3 Heater mat for drainpan (EKDP008C) Pair of flexi feet to mount the outdoor unit Wall mounting bracket for outdoor unit Condensate drip tray for K.CWB90-2 Outdoor unit guard Fernox magnetic filter 1” Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £177.00 EKHY075787 EKHY090717 EKPCCAB3 EKRP1HBA EKRUCBS RTRNETA3AA EKRSC1* KRCS01-1* EKFT008CA EKDP008C EKDPH008C K.FF600ASN K.CWB90-2 K.DT1 K.CGM K.FERNOXTF1 K.FERNOXTF1FL £113.00 i) * Only one optional remote sensor can be installed £20.00 £20.00 £188.00 £108.00 £83.00 £188.00 £63.00 £48.00 £86.00 £121.00 £183.00 £49.00 £37.00 £56.00 £308.00 £97.00 £113.00 HEATING K.ELECMETV Notes: Features: > Revolutionary hybrid heat pump system with higher efficiency and higher running cost savings than condensing boiler alone > Boiler can be converted to run on LPG > Delivered as a set including outdoor unit, indoor unit, boiler, controller and pipe cover plate > Flues ordered separately Daikin Altherma Hybrid Heat Pump System Hybrid Tank Connection Kits Part Number Description Trade Price EKEPHT3H Daikin thermal store (EKHWP-B) £181.00 This pack contains: 3 way valve (Honeywell) Tank sensor (HT + adapter) 2 x isolation valves T-piece EKHY3PART Third party tank – dry pocket sensor £151.00 This pack contains: 3 way valve (ESBE) Tank sensor (LT) EKHY3PART2 Third party tank – thermostat only £182.00 This pack contains: 3 way valve (ESBE) Wire harness Price List Update: Valid from 1st January 2017 135 Daikin Altherma Hybrid Heat Pump System HEATING Flue Accessories (60/100) 136 Description Quantity per pack Part number Trade Price Horizontal flue kit 60/100 1 EKFGP1292 £43.00 Horizontal flue kit with low profile elbow 60/100 1 EKFGP1293 £54.00 Extension 60/100 x 500mm 1 EKFGP4651 £26.00 Extension 60/100 x 1000mm 1 EKFGP4652 £31.00 Elbow 60/100, 30 degrees 1 EKFGP4664 £34.00 Elbow 60/100, 45 degrees 1 EKFGP4661 £22.00 Elbow 60/100, 87 degrees 1 EKFGP4660 £22.00 Tee with inspection panel 60/100 1 EKFGP4667 £85.00 Wall bracket DN.100 1 EKFGP4631 £6.00 Plume Management Kit (PMK) 1 EKFGP1294 £37.00 Flue deflector 1 EKFGP1295 £14.00 Residential, Commercial and Industrial Daikin Altherma Hybrid Heat Pump System Flue Accessories (60/100) (Continued) Quantity per pack Part number Trade Price PMK elbow, 87 degrees 1 EKFGP1284 £12.00 PMK elbow, 45 degrees 2 EKFGP1285 £20.00 PMK extension, length 1000mm incl. bracket 1 EKFGP1286 £18.00 Vertical roof terminal 60/100 1 EKFGP6837 £62.00 Weather slate (plastic) 60/100 (25-45 degrees) 1 EKFGP7910 £28.00 18-22 degrees 1 EKFGS0518 £94.00 23-27 degrees 1 EKFGS0519 £94.00 43-47 degrees 1 EKFGS0523 £94.00 48-52 degrees 1 EKFGS0524 £94.00 53-57 degrees 1 EKFGS0525 £94.00 Weather slate flat aluminium 60/100 1 EKFGP6940 £20.00 Weather slate flat aluminium 60/100 (0 – 15 degrees) 1 EKFGP1296 £52.00 HEATING Description Weather slate 60/100 Price List Update: Valid from 1st January 2017 137 Netatmo HEATING Y TO EAS EC T N CON WIFI TO Netatmo by Starck Take control of your home’s temperature with the Thermostat for smartphones, tablets, and laptops, designed by Starck. Accessory Trade Unit Price Temperature (setpoint) Wireless Specifications > Once installed, Netatmo gives the user precise remote control of heat output, a weekly schedule reflecting the family’s habits and monthly energy savings reports. This can help you reduce your energy consumption by up to 25% by only heating when you need it. Netatmo Smart Thermostat £188.00 Dimensions Temperature (measures) > W ith all the functionality of a programmable room thermostat, Netatmo may be fixed to a wall or used wirelessly. It is installed together with a user interface on smartphone, tablet or computer. RTRNETA3AA Description Product fiche Netatmo gives homeowners the option to control their heating temperature via an easy to use smartphone app. Height Width Depth Class Contribution Range Accuracy Setpoint range Increment measure Wi-Fi Security Power % °C °C °C °C 83 83 22 IV 2.0 0 ~ 50 ±0.5 5 ~ 30 0.5 802.11b/g/n (2.4GHz) Open/WEP/WPA/WPA2-Personal (TKIP et AES) 3 AAA batteries Netatmo combination tables: Product Series Daikin Altherma air source heat pump EHBH-CB EDLQ-C* EDHQ-BB EKHBRD-AD** EHYHBH-A *Wiring centre EKCB07CV3 **Option PCB type EKRP1AHTA is required 138 Residential, Commercial and Industrial Energy savings Comfort at the right time with Auto-Adapt function Remote control Unique design by Starck Daikin solar systems maximise the use of renewable free energy from the sun through high efficiency flat plate collectors. The Daikin solar thermal system is available in drainback and pressurised options and is designed to work in conjunction with Daikin Altherma air-to-water heat pumps for maximum efficiency. Solar panels are Solar Keymark approved and eligible for the Domestic RHI. Drainback solar system Pressurised solar system > T he drainback solar system is a low maintenance system which does not need antifreeze agents > T he pressurised solar system transfers heat to the unvented cylinder via a specially designed heat exchanger kit. This allows the entire cylinder to be heated by solar energy > It consists of an unpressurised thermal store which can be combined with Daikin Altherma heat pumps or another auxiliary heat source > W ater in the store is pumped to the solar panels, heated and returns to stratify in the Daikin thermal store > W hen solar energy is not available, the solar collectors empty and water drains back to the store > D uring solar heating, the heat pump is disabled to ensure maximum efficiency Standalone solar system > T he standalone solar system combines a pressurised solar system and a twin-coil unvented cylinder and is designed to be combined with an auxiliary gas boiler > Ideal for on-gas retrofit applications Solar pressurised Solar drainback Price List Update: Valid from 1st January 2017 139 HEATING Solar Thermal Solar Panel EKSV / EKSH Type Dimensions Height x Width x Depth Weight Max operating pressure Max standstill temp Information for SAP assessors and for MCS installers Gross / net aperture area Zero loss efficiency Heat loss coefficient (a1) Heat loss coefficient (a2) Solar panel mm kg Bar °C m2 W/m2.K W/m2.K2 Solar pump station Solar controller DHW Thermal Store EKSV21P Vertical 2000 x 1006 x 85 35 6 200 EKSV26P Vertical 2000 x 1300 x 85 42 6 200 EKSH26P Horizontal 1300 x 2000 x 85 42 6 200 2.0 / 1.8 0.784 4.25 0.0072 2.6 / 2.36 0.784 4.25 0.0072 2.6 / 2.36 0.784 4.25 0.0072 Solar Pump Station EKSRD / EKSRP System Dimensions Height x Width x Depth Power supply Solar pump Max pump power consumption Max operating pressure Max pump capacity Temperature range Connections mm W Bar m3/h °C - EKSRDS2A pressurised 410 x 240 x 130 230 / 50Hz Grundfos UPM3 Solar 25-75 22.5 6 2 0-120 (160 short term) 1¼” female for Ø 22 clamping ring bolt (x4) EKSRPS4A drainback 230 x 815 x 142 230 / 50Hz Grundfos UPS 15-145 65 - 162084 60 x 145 x 95 230 / 50Hz 5 Plain text Part of EKSRPS4A 230 / 50Hz 2 Plain text HEATING Solar Controller Dimensions Power supply Max electric consumption Display Height x Width x Depth mm W DHW Thermal Store EKHWP Storage capacity Weight (empty) Weight (filled) Dimensions Height x Width x Depth Max storage temp Heat loss at 60°C Energy efficiency class Standing heat loss Storage volume Coil material Potable water capacity Max operating pressure (potable water) DHW coil area Solar thermal system Information for SAP assessors and for MCS installers Total volume (V) Dedicated solar volume (Vs) Surface area solar heat exchange coil Heating coil capacity Heating coil area Pipe connections Cold and hot water Heating flow / return Solar Thermal output data Volume of hot water at given draw-off rate; without reheating (inlet = 10 °C / outlet = 40 °C / store = 50 °C) Reheat time (Wh) at given draw-off volume (inlet = 10 °C / outlet = 40 °C / store = 50 °C) litres kgs kgs mm °C kWh/24h W L litres Bar m2 140 EKHWP500B EKHWP300PB 500 300 93 64 593 364 1640 x 790 x 790 595 x 615 x 1646 85 85 1.4 1.3 B B 72 64 477 294 Stainless Steel 1.4404 29.0 27.9 6 6 6.0 2.7 27.9 6 5.8 Drainback litres litres m2 litres m2 EKHWP500PB 500 98 598 790 x 790 x 1658 85 1.4 B 72 477 29.0 6 3.8 Pressurised 300 300 N/A 13.2 2.7 Inches Inches Inches 500 500 N/A 18.5 3.8 1” outer thread 1” female / 1” male 1” internal thread 300 300 0.8 13.2 2.7 500 500 1.7 18.5 3.8 1” male 1” female / 1” male 3/4” female and 1” male litres 8 l/min = 184 12 l/min = 153 8 l/min = 364 (1) 12 l/min = 318 (1) 8 l/m = 184 12 l/m = 153 8 l/m = 324 (1) 12 l/m = 282 (1) mins With 8kW heat pump 90 litres = 30 140 litres = 45 EKHWP300B ERLQ004-8 EKDVCPLT3HX EKBH3S ERSQ011-16 EKEPHT3H 16 51 35 With 16kW heat pump 90 litres = 17 140 litres = 25 EKHWP500B ERLQ011-16 EKDVCPLT5H EKBH3S ERSQ011-16 EKEPHT5H 16 51 35 With 8kW heat pump 90 litres = 30 140 litres = 45 EKHWP300PB ERLQ004-8 EKDVCPLT3HX EKBH3S ERSQ011-16 EKEPHT3H 16 51 35 With 16kW heat pump 90 litres = 17 140 litres = 25 EKHWP500PB ERLQ011-16 EKDVCPLT5H EKBH3S ERSQ011-16 EKEPHT5H 16 51 35 DHW Thermal store combination Daikin Altherma LT Connection kit (2) Immersion heater (required) Daikin Altherma HT Connection kit Immersion heater (optional) 1. with immersion heater EKHWP300B 300 59 359 1640 x 615 x 595 85 1.4 B 64 294 2. connection kits include 3 way valve, sensors and isolation valves Residential, Commercial and Industrial Daikin Solar Thermal System Solar Panels, Fixings and Installation Kits (common components) Description Part number Trade Price Solar panel (vertical) – standard (2000 x 1300 x 85mm), aperture area 2.35m2, weight 42kg, water content 1.7 L. Max. 6 bar EKSV26P £421.00 EKSV21P £352.00 EKSH26P £432.00 Kit to couple 2 solar panels Mounting profile connector, expansion joints and double clamping blocks 162016-RTX £36.00 Mounting rail for vertical panels Consisting of mounting profile rails and solar panel securing ties 162066 For EKSV21P (Was 162013) £25.00 162067 For EKSV26P (Was EKSFIXMP130) £31.00 162068 For EKSH26P (Was EKSFIXMP200) £42.00 162036-RTX £72.00 164723 £40.00 164703-RTX £52.00 Note: Max 5 panels Solar panel (vertical) – small (2000 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar Note: Max 5 panels Solar panel (horizontal) – standard (1300 x 2000 x 85mm), aperture area 2.35m2, weight 42kg, water content 2.1 L. Max. 6 bar Note: Different for standard and small panels 4x Support hooks for high profile tiles 4 double height-adjustable roof ties including fixing material for one solar panel HEATING Note: For pressurised systems only Note: Was EKSFIXADP 4x Support hooks for flat tiles (slate) 4 roof ties for flat roofing, e.g. slate, for one solar panel Note: Was EKSFIXADS 4x Support hooks for curved roofings Including fixing material for one solar panel Note: Was EKSFIXWD Price List Update: Valid from 1st January 2017 141 Daikin Solar Thermal System Solar Panels, Fixings and Installation Kits (common components) Description Part number Trade Price 4x Support hooks for sheet metal roofs Including fixing material for one solar panel 164704-RTX £49.00 162019 For EKSV26P £267.00 162017 For EKSV21P £444.00 162020 For EKSV26P £207.00 162018 For EKSV21P £198.00 162058 £398.00 162059 £158.00 162060 £189.00 162061 £130.00 164110-RTX £11.00 EKRP1HBA £108.00 Note: Was EKSFIXBD In-roof installation kit for 2x vertical panels For two solar panels, covering sheets complete with mounting material. Minimum roof angle 15° Note: Different for standard and small panels In-roof extension kit for 1 additional vertical panel For one further solar panel, covering sheets complete with mounting material. Minimum roof angle 15° Note: Different for standard and small panels Flat roof kit for 2x vertical panels Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees HEATING Note: For EKSV26P only Flat roof extension kit for 1 additional vertical panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSV26P only Flat roof kit for 1 horizontal panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSH26P only Flat roof extension kit for 1 additional horizontal panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSH26P only Connection cable to disable heat pump The connection cable is required to connect the solar priority PCB kit to heat pump Note: Need to order EKRP1HBA with this part Was EKS164110 Solar priority PCB kit This enables an interlock between the Daikin solar controller and Altherma heat pumps Note: Need to order 164110-RTX with this part 142 Residential, Commercial and Industrial Daikin Solar Thermal System Solar Pressurised Accessories Description Part number Trade Price 162084 Solar controller Solar differential temperature regulation for the Daikin solar pressurised system. Regulator with graphic display for representation of hydraulic schematics and yield balances. Including return flow and storage tank temperature sensor and housing for wall mounting £199.00 Pump station Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator, ball valves with integrated backflow preventor, Grundfos UPM3 Solar 25-75 pump, safety group with pressure gauge, including insulation and mounting accessories EKSRDS2A £296.00 Hydraulic connection kit (pressurised) Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant heat insulation for the external area, solar panel temperature sensor and end caps EKSRCP £117.00 Connection pipe for solar panel rows Connection kit for connecting two rows of collectors one above the other. Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping 162045 £78.00 162052-RTX £73.00 Thermostatic Mixing Valve Thermal safety device for DHW outlet with a setting range from 35-60°C UK.SPMIXVALVE £93.00 15m solar pressurised pipe Pre-insulated stainless steel flexible flow to panel (16mm) and return from panel (20mm) pipe with sensor cable, order with fittings as shown UK.SP3PIPEP Up to 3 panels (DN16) £285.00 Note: Order connection pack separately 162073 + 162075 was 162021-RTX 162074 + 162076 was 162026-RTX UK.SP5PIPEP 4-5 panels (DN20) £416.00 Solar pipe connectors Connectors to fit 2 pipes together for extension of solar pipe 162071 Up to 25m (DN16) £25.00 162072 Up to 25m (DN20) £20.00 162050 25 litre £58.00 162051-RTX 35 litre £150.00 Antifreeze fluid (glycol, 20L) 20L of pre-mixed solar fluid in a canister, SOL 5F. Functional range up to -28°C HEATING Note: Was EKSCONLCP Note: Was EKSGFL Note: 162071 was 162027-RTX 162072 was 162028-RTX Solar expansion vessel Bracket and flexi hose included for installation Price List Update: Valid from 1st January 2017 143 Daikin Solar Thermal System Solar Drainback Accessories Description Part number Trade Price Solar controller and pump station Unit ready to plug in (230V), with digital differential temperature control system, return flow and storage tank temperature sensors and operating pump EKSRPS4A £433.00 Solar connection pipe Ready to plug in connection pipe between the solar panel and the pump station, consisting of thermally insulated flow pipe to panel (15mm) and return pipe from panel (18mm) with integrated sensor cable. Available in 15 and 20m lengths 164732 15m length £98.00 164733 20m length £117.00 164261-RTX 2.5m £61.00 164262-RTX 5m £70.00 164263 10m £88.00 164264 £77.00 Copper pipe connection kit 164232 Connection kit when connecting onto copper pipe (if Daikin drainback pipe is not used). Consisting of 2m flow and return pipes, push-fit coupling onto 15mm and 18mm copper pipe £56.00 Solar panel row connection kit Connection kit for connecting two rows of collectors one above the other. Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping 162035-RTX £65.00 EKSRCRP Brick red £160.00 EKSRCAP Anthracite £160.00 162037-RTX £104.00 Note: 164732 was EKSCON15 164733 was EKSCON20 Solar connection pipe extension Ready to plug in, including fitting materials and connection fittings. Available in 2.5, 5 and 10m lengths Note: 164261-RTX was EKSCONX25 164262-RTX was EKSCONX50 164263 was EKSCONX100 HEATING Maximum possible length of the connection pipe Number of solar panels Max. length 2 3 4 5 45m 30m 17m 15m Solar flow pipe extension (15mm) UV resistant thermally insulated, length L = 8m, including cable connection fitting for the solar panel sensor line Note: Was EKSCONXV80 Note: Was EKSCONRVP Hydraulic connection kit (on-roof) Connection kit for drainback (on-roof ), includes connection to solar panel, pitched roof flashing, 2m UV resistant insulation, solar panel temperature sensor and endcaps Available in Anthracite or Brick red Hydraulic connection kit (in-roof) Connection kit for drainback (in-roof ), includes connection to solar panel, solar panel temperature sensor and endcaps 144 Residential, Commercial and Industrial Daikin Solar Thermal System Solar Drainback Accessories (Continued) Description Part number Trade Price Hydraulic connection kit (flat roof) Connection kit for drainback (flat roof ), includes connection to solar panel, flat roof penetration, 8.5m UV resistant insulation and solar panel temperature sensor 162038-RTX £202.00 Gravity break set Avoids thermal heat loss from thermal store due to thermo-siphon effect. Advised when piping from heat exchanger is not making a down ward bend at the tank 165070 £8.00 Solar flow setter Flow regulating valve with flow indicator (2-16 l/min). For balancing solar flow in cascade thermal store installations 164102-RTX £55.00 165113 £82.00 Note: For use only with EKHWP* only Secondary circulation kit Connection kit for secondary hot water connections HEATING Note: For use with EKHWP* only Daikin Solar Thermal System Thermal Store for Daikin Altherma High and Low Temperature This is a hot water thermal storage tank and provides instantaneous hot water. The tank serves as a heat storage medium. It can be heated by both Daikin Altherma heat pumps and solar energy, available for both drainback and pressurised applications. Description Part number Trade Price EKHWP300B with connection kit for ERSQ011-016 UK.THERMAL300DBHT £1,206.00 EKHWP500B with connection kit for ERSQ011-016 UK.THERMAL500DBHT £1,467.00 EKHWP300B with connection kit for ERLQ004-008 & EDLQ05-07 and 3kW immersion heater UK.THERMAL300DBLT £1,369.00 EKHWP500B with connection kit for ERLQ011-016 & E(D/B)HQ014-D16 and 3kW immersion heater UK.THERMAL500DBLT £1,660.00 EKHWP300PB with connection kit for ERSQ011-016 UK.THERMAL300PHT £1,297.00 EKHWP500PB with connection kit for ERSQ011-016 UK.THERMAL500PHT £1,652.00 Drainback Solar Thermal store (EKHWP***B) Combination with Daikin Altherma HT Drainback Solar Thermal store (EKHWP***B) Combination with Daikin Altherma LT & MB Pressurised Solar Thermal store (EKHWP***PB) Combination with Daikin Altherma HT Pressurised Solar Thermal store (EKHWP***PB) Combination with Daikin Altherma LT & MB EKHWP300PB with connection kit for ERLQ004-008 & EDLQ05-07 and 3kW immersion heater UK.THERMAL300PLT £1,460.00 EKHWP500PB with connection kit for ERLQ011-016 & E(D/B)HQ014-016 and 3kW immersion heater UK.THERMAL500PLT £1,845.00 Connection elbow enables easy filling and draining of the storage tank 165210 £21.00 165215 £24.00 Note: It is recommended that 165210 and 165215 are ordered with every thermal store Fill and drain connection Note: It is recommended that 165210 and 165215 are ordered with every thermal store Price List Update: Valid from 1st January 2017 145 Daikin Solar Thermal System Solar Standalone Accessories The standalone pressurised solar system is designed for use with auxiliary gas boiler and twin coil cylinder. Available in predefined on-roof and in-roof packs (see page 152) Description Part number Trade Price Solar panel (vertical) – small (2006 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar EKSV21P £352.00 Mounting rail for small panels Consisting of mounting profile rails and securing ties 162066 £25.00 162036-RTX £72.00 164723 £40.00 Pump station Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator, ball valves with integrated backflow preventor, Grundfos UPM3 Solar 25-75 pump, safety group with pressure gauge, including insulation and mounting accessories EKSRDS2A £296.00 Hydraulic connection kit (pressurised) Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant heat insulation for the external area, solar panel temperature sensor and endcaps EKSRCP £117.00 Solar controller for standalone solar Wall mounted, small and compact. Easy to use solar controller with back-lit graphical illuminated display. Auxiliary heat source timer and pump speed control UK.SOLCTRBS4 £199.00 FKU-HWS200TC 200L £500.00* FKU-HWS250TC 250L £525.00* FKU-HWS300TC 300L £570.00* Note: Was 162013 4x Support hooks for high profile tiles 4 double height-adjustable roof ties including fixing material for one solar panel Note: Was EKSFIXADP 4x Support hooks for flat tiles (slate) 4 roof ties for flat roofing, e.g. slate, for one solar panel HEATING Note: Was EKSFIXADS Note: To control auxiliary gas boiler only Twin coil solar cylinder Unvented stainless steel cylinder. Designed for gas boiler auxiliary heating and solar hot water connections. Delivered with full G3 compliance kit including 2-port motorised valve (except expansion vessel - field supply) Note: Further standalone solar components are available to complete the standalone system (see pages 141-143) * Special offer price 146 Residential, Commercial and Industrial Selecting the right Solar System Daikin has a full range of solar thermal solutions including Drainback and Pressurised solutions to suit many installation requirements. Solar systems are available to work with heat pumps or with boilers and offer enhanced DHW energy savings. Use the table below to help select the right kind of solar system for your Daikin heat pump or your existing boiler. Auxiliary heat source Drainback Pressurised HT, LT & Hybrid Heat Pump HT, LT & Hybrid Heat Pump Boiler Thermal Store Thermal Store Twin coil (EKHWP-B) (EKHWP-PB) (FKU) Tank Vertical 2.6m2 Vertical 2.0m2 Vertical 2.6m2 Horizontal 2.6m2 HEATING Solar system Vertical 2.0m2 Panel orientation and size On-roof 3 (page 149) In-roof Flat roof 3 3 (page 152) 3 (page 149) (page 152) 3 7 (page 149) 3 (page 150) 3 (page 151) 3 (page 151) 3 3 (page 150) (page 152) 7 (page 152) 3 (page 151) 3 7 Price List Update: Valid from 1st January 2017 147 Selecting the right Solar Pack Daikin offer solar systems in ready to order packs with all the key components include. After deciding between drainback or pressurised solar, use this table to select the right solar pack for your project. Daikin Solar Thermal System HEATING Solar Packs – Quick Selection Table System type Orientation Fixing type Tile Roof cowl 1 panel pack 2 panel pack 3 panel pack 4 panel pack 5 panel pack Drainback Vertical On-roof Profiled tile Anthracite UK.SP1VPDBA UK.SP2VPDBA UK.SP3VPDBA UK.SP4VPDBA UK.SP5VPDBA Slate/flat tile Anthracite UK.SP1VSDBA UK.SP2VSDBA UK.SP3VSDBA UK.SP4VSDBA UK.SP5VSDBA Profiled tile Red UK.SP1VPDBR UK.SP2VPDBR UK.SP3VPDBR UK.SP4VPDBR UK.SP5VPDBR Slate/flat tile Red UK.SP1VSDBR UK.SP2VSDBR UK.SP3VSDBR UK.SP4VSDBR UK.SP5VSDBR In-roof Profiled/slate/ flat tile - - UK.SP2VIDBA UK.SP3VIDBA UK.SP4VIDBA UK.SP5VIDBA Flat-roof - - UK.SP1VADBA UK.SP2VADBA UK.SP3VADBA UK.SP4VADBA UK.SP5VADBA On-roof Profiled tile - UK.SP1VPP UK.SP2VPP UK.SP3VPP - - Slate/flat tile - UK.SP1VSP UK.SP2VSP UK.SP3VSP In-roof Profiled/slate/ flat tile - - UK.SP2VIP UK.SP3VIP Flat-roof - - UK.SP1VAP UK.SP2VAP UK.SP3VAP On-roof Profiled tile - UK.SP1HPP UK.SP2HPP UK.SP3HPP Slate/flat tile - UK.SP1HSP UK.SP2HSP UK.SP3HSP Flat-roof - - UK.SP1HAP UK.SP2HAP UK.SP3HAP On-roof Profiled tile - UK.V21PP1 UK.V21PP2 UK.V21PP3 - - Slate/flat tile - UK.V21SP1 UK.V21SP2 UK.V21SP3 Profiled/slate/ flat tile - - UK.V21IP2 UK.V21IP3 Pressurised Vertical Horizontal Pressurised (Standalone) Vertical In-roof 148 Residential, Commercial and Industrial Daikin Solar Thermal System Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for concrete / profiled x 4 Mounting rail for panel Hydraulic connection kit (on-roof ) including cowl in either: Solar controller & pump station* Coupling kit for multiple panels Connection cable to disable heat pump Pack price Part number Anthracite / Red EKSRPS4A 162016-RTX 164110-RTX Vertical on-roof slate tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit (on-roof ) including cowl in either: Solar controller & pump station* Coupling kit for multiple panels Connection cable to disable heat pump Pack price Vertical in-roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit (in-roof ) Solar controller & pump station* Coupling kit for multiple panels In-roof kit for 2x vertical panels In-roof extension kit for 1x panel Connection cable to disable heat pump Pack price Vertical flat roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit (flat roof ) including flat roof penetration Solar controller & pump station* Coupling kit for multiple panels Solar flat roof kit for 2xV26P Solar flat roof kit for additional V26P Connection cable to disable heat pump Pack price EKSV26P 162036-RTX 162067 EKSRCAP / EKSRCRP Part number Anthracite / Red 1 panel pack 2 panel pack 3 panel pack 4 panel pack 5 panel pack UK.SP1VPDBA/R Quantity 1 1 1 1 UK.SP2VPDBA/R Quantity 2 2 2 1 UK.SP3VPDBA/R Quantity 3 3 3 1 UK.SP4VPDBA/R Quantity 4 4 4 1 UK.SP5VPDBA/R Quantity 5 5 5 1 1 0 1 £968.00 1 1 1 £1,528.00 1 2 1 £2,088.00 1 3 1 £2,648.00 1 4 1 £3,208.00 1 panel pack 2 panel pack 3 panel pack 4 panel pack 5 panel pack UK.SP1VSDBA/R Quantity 1 1 1 1 UK.SP2VSDBA/R Quantity 2 2 2 1 UK.SP3VSDBA/R Quantity 3 3 3 1 UK.SP4VSDBA/R Quantity 4 4 4 1 UK.SP5VSDBA/R Quantity 5 5 5 1 EKSRPS4A 162016-RTX 164110-RTX 1 0 1 £936.00 1 1 1 £1,464.00 1 2 1 £1,992.00 1 3 1 £2,520.00 1 4 1 £3,048.00 Part number 1 panel pack 2 panel pack 3 panel pack 4 panel pack 5 panel pack Quantity - UK.SP2VIDBA/R Quantity 2 2 1 1 1 1 0 1 £1,755.00 UK.SP3VIDBA/R Quantity 3 3 1 1 2 1 1 1 £2,450.00 UK.SP4VIDBA/R Quantity 4 4 1 1 3 1 2 1 £3,145.00 UK.SP5VIDBA/R Quantity 5 5 1 1 4 1 3 1 £3,840.00 EKSV26P 164723 162067 EKSRCAP / EKSRCRP EKSV26P 162067 162037-RTX EKSRPS4A 162016-RTX 162019 162020 164110-RTX Part number 1 panel pack 2 panel pack 3 panel pack 4 panel pack 5 panel pack EKSV26P 162067 162038-RTX UK.SP1VADBA/R Quantity 1 1 1 UK.SP2VADBA/R Quantity 2 2 1 UK.SP3VADBA/R Quantity 3 3 1 UK.SP4VADBA/R Quantity 4 4 1 UK.SP5VADBA/R Quantity 5 5 1 1 0 1 0 1 £1,496.00 1 1 1 0 1 £1,984.00 1 2 1 1 1 £2,630.00 1 3 1 2 1 £3,276.00 1 4 1 3 1 £3,922.00 EKSRPS4A 162016-RTX 162058 162059 164110-RTX Important: When installing an Daikin Altherma heat pump and Daikin drainback solar system, the following accessories need to be ordered separately: EKHWP-B – Thermal store EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3 EKSCON*** – Solar connection pipe *When installing an integrated ROTEX Gas Compact Unit and Daikin drainback solar system, order 164126 instead of EKSRPS4A Price List Update: Valid from 1st January 2017 149 HEATING Solar Packs – Drainback System for Daikin Altherma Daikin Solar Thermal System Solar Packs – Pressurised System for Daikin Altherma Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Vertical on-roof slate / flat tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price HEATING Horizontal on-roof profiled tile pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Horizontal on-roof slate / flat tile pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Roof brackets for slate/flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Part number EKSV26P 162036-RTX 162067 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162050 164110-RTX Part number EKSV26P 164723 162067 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162050 164110-RTX Part number EKSH26P 162036-RTX 162068 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162050 164110-RTX Part number EKSH26P 164723 162068 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162050 164110-RTX 1 panel pack 2 panel pack 3 panel pack UK.SP1VPP Quantity 1 1 1 1 1 1 1 0 1 1 £1,205.00 UK.SP2VPP Quantity 2 2 2 1 1 1 1 1 1 1 £1,765.00 UK.SP3VPP Quantity 3 3 3 1 1 1 1 2 1 1 £2,325.00 1 panel pack 2 panel pack 3 panel pack UK.SP1VSP Quantity 1 1 1 1 1 1 1 0 1 1 £1,173.00 UK.SP2VSP Quantity 2 2 2 1 1 1 1 1 1 1 £1,701.00 UK.SP3VSP Quantity 3 3 3 1 1 1 1 2 1 1 £2,229.00 1 panel pack 2 panel pack 3 panel pack UK.SP1HPP Quantity 1 1 1 1 1 1 1 0 1 1 £1,227.00 UK.SP2HPP Quantity 2 2 2 1 1 1 1 1 1 1 £1,809.00 UK.SP3HPP Quantity 3 3 3 1 1 1 1 2 1 1 £2,391.00 1 panel pack 2 panel pack 3 panel pack UK.SP1HSP Quantity 1 1 1 1 1 1 1 0 1 1 £1,195.00 UK.SP2HSP Quantity 2 2 2 1 1 1 1 1 1 1 £1,745.00 UK.SP3HSP Quantity 3 3 3 1 1 1 1 2 1 1 £2,295.00 Important: When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately: EKHWP-PB - Thermal store 1620** – Solar pressurised pipe and connectors EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3 150 Residential, Commercial and Industrial Daikin Solar Thermal System Vertical in-roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 Litres) Coupling kit for multiple panels In roof kit for 2 x V26P In roof extension kit for additional V26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Vertical flat roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 Litres) Coupling kit for multiple panels Solar flat roof kit for 2xV26P Solar flat roof kit for additional V26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Horizontal flat roof pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Solar fluid (20 Litres) Coupling kit for multiple panels Solar flat roof kit for H26P Solar flat roof kit for additional H26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price Part number EKSV26P 162067 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162019 162020 162050 164110-RTX Part number EKSV26P 162067 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162058 162059 162050 164110-RTX Part number EKSH26P 162068 EKSRCP 162084 EKSRDS2A 162052-RTX 162016-RTX 162060 162061 162050 164110-RTX (Continued) 2 panel pack 3 panel pack UK.SP2VIP Quantity 2 2 1 1 1 1 1 1 0 1 1 £1,607.00 UK.SP3VIP Quantity 3 3 1 1 1 1 2 1 1 1 1 £2,106.00 1 panel pack* 2 panel pack 3 panel pack UK.SP1VAP Quantity 1 1 1 1 1 1 0 1 0 1 1 £1,531.00 UK.SP2VAP Quantity 2 2 1 1 1 1 1 1 0 1 1 £2,019.00 UK.SP3VAP Quantity 3 3 1 1 1 1 2 1 1 1 1 £2,665.00 1 panel pack 2 panel pack 3 panel pack UK.SP1HAP Quantity 1 1 1 1 1 1 0 1 0 1 1 £1,344.00 UK.SP2HAP Quantity 2 2 1 1 1 1 1 1 1 1 1 £1,984.00 UK.SP3HAP Quantity 3 3 1 1 1 1 2 1 2 1 1 £2,624.00 HEATING Solar Packs – Pressurised System for Daikin Altherma * Important: When ordering the vertical flat roof pack, please be aware the solar flat roof kit is sufficient for two vertical panels, thus some wastage will occur (the wastage is not enough to be used for another panel). Important: When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately: EKHWP-PB - Thermal store 1620** – Solar pressurised pipe and connectors EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3 Price List Update: Valid from 1st January 2017 151 Daikin Solar Thermal System Solar Packs – Standalone Pressurised System for use with Auxiliary Gas Boiler Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Pack price Vertical on-roof slate / flat tile pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Pack price HEATING Vertical in-roof pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) In roof kit for 2 x V21P In roof extension kit for additional V21P Pack price Part number EKSV21P 162036-RTX 162066 EKSRCP UK.SOLCTRBS4 EKSRDS2A 162052-RTX 162016-RTX 162050 Part number EKSV21P 164723 162066 EKSRCP UK.SOLCTRBS4 EKSRDS2A 162052-RTX 162016-RTX 162050 Part number EKSV21P 162066 EKSRCP UK.SOLCTRBS4 EKSRDS2A 162052-RTX 162016-RTX 162050 162017 162018 1 panel pack 2 panel pack 3 panel pack UK.V21PP1 Quantity 1 1 1 1 1 1 1 0 1 £1,047.00 UK.V21PP2 Quantity 2 2 2 1 1 1 1 1 1 £1,460.00 UK.V21PP3 Quantity 3 3 3 1 1 1 1 2 1 £1,873.00 1 panel pack 2 panel pack 3 panel pack UK.V21SP1 Quantity 1 1 1 1 1 1 1 0 1 £1,047.00 UK.V21SP2 Quantity 2 2 2 1 1 1 1 1 1 £1,460.00 UK.V21SP3 Quantity 3 3 3 1 1 1 1 2 1 £1,873.00 2 panel pack 3 panel pack UK.V21IP2 Quantity 2 2 1 1 1 1 1 1 1 0 £1,460.00 UK.V21IP3 Quantity 3 3 1 1 1 1 2 1 1 1 £1,873.00 Important: Packs detailed above are not designed to be used with Daikin Altherma heat pumps. The above packs are designed to be used with an auxiliary gas boiler and twin coil cylinder. To complete the Daikin standalone pressurised solar system, please order twin coil cylinder (FKU-HWS***TC). 152 Residential, Commercial and Industrial HEATING Underfloor Heating ROTEX underfloor heating system is designed to work seamlessly with the Daikin Altherma range to provide high heat pump efficiency and low surface temperatures for the most comfortable room climate. When partnered with heat pumps, UFH with low flow temperatures helps to achieve high heat pump efficiencies and even higher running cost savings. > Energy saving and highly versatile, can be used with heat pumps and condensing boilers > Simple installation with easy to lay components > Additional energy benefits recognised in SAP and MCS > R otex Monopex is ideal for low temperature systems such as heat pumps and is available in a variety of pipe sizes > R otex System 70 is ideal for mixed UFH and radiator systems and commercial heating systems with primary flow temperatures 55 - 70°C For information on Daikin’s underfloor heating design process go to page 156. Price List Update: Valid from 1st January 2017 153 Underfloor Heating System Heat Emission Plate Dual channel aluminium spreader plates for timber suspended or battened floor installations. For joists at 400mm centres. Plate dimensions 1000x390mm Description Length Part number Trade Price Spreader plates For Ø 17mm pipe 10 (3.9m2) 171141 £70.00 Underfloor Heating System Underfloor Heating Pipes HEATING Monopex heating pipes: Thick-walled, linked basic PE-X pipe with oxygen-tight barrier for Monopex low temperature underfloor heating systems. Description Length Part number Trade Price Monopex 14 PE-X 14 x 2 OD For Monopex underfloor heating system 120m 170008 £133.00 240m 170009 £266.00 Monopex 14 ALU thick-walled PE-X 14 x 2 OD Aluminium coating and PE external layer. For Monopex underfloor heating systems 120m 170604 £189.00 240m 170605 £375.00 Monopex 17 PE-X 17 x 2 OD For Monopex underfloor heating system 120m 170029 £148.00 240m 170028 £295.00 600m 170062 £734.00 120m 170030 £170.00 240m 170109 £338.00 400m 170108 £562.00 25m 170053 Ø 19/25mm £15.00 25m 170098 Ø 16/21mm £12.00 75m 170001 Ø 23/28mm £49.00 120m 170068 £207.00 240m 170086 £414.00 120m 170601 £239.00 240m 170602 £476.00 200m 170050 £453.00 Monopex 20 PE-X 20 x 2 OD For Monopex underfloor heating system Protective pipe Black corrugated pipe made of plastic as additional insulation in the area of the manifold and expansion joints DUO heating pipes: Thick-walled linked PE-X basic pipe, with oxygen-tight barrier, and additional highly flexible PE ribbed pipe. For underfloor heating systems operated in direct combination with other heating surfaces, e.g. radiators. DUO 17 PE-X 17/12 x 2 OD For system 70 underfloor heating & heating radiator connection Outer pipe Ø 17mm Inner pipe 12 x 2mm DUO 17 ALU PE-X 17/12 x 2 OD With aluminium coating and PE external layer. For system 70 radiator connection and underfloor heating Outer pipe Ø 17mm Inner pipe 12 x 2mm DUO 25 PE-X 25/18 x 2 OD For system 70 industrial underfloor heating 154 Residential, Commercial and Industrial Underfloor Heating System Manifolds RMX manifold: RMX heating circuit manifold, for underfloor heating systems and radiators. Suitable for the smallest fitting heights. Buy clamping ring sets separately to suit pipe. Description Quantity per pack Part number Trade Price Manifold RMX 2-port 1 172702 £110.00 Manifold RMX 3-port 1 172703 £129.00 Manifold RMX 4-port 1 172704 £152.00 Manifold RMX 5-port 1 172705 £174.00 Manifold RMX 6-port 1 172706 £197.00 Manifold RMX 7-port 1 172707 £220.00 Manifold RMX 8-port 1 172708 £242.00 Manifold RMX 9-port 1 172709 £265.00 Manifold RMX 10-port 1 172710 £288.00 Manifold RMX 11-port 1 172711 £308.00 Manifold RMX 12-port 1 172712 £332.00 RMX actutator (230V) Actuator for RMX manifold and kombi box 1 175145 £18.00 RMX connection set DUO17 2 170312 £8.00 RMX connection set Monopex 14 2 170314 £8.00 RMX connection set Monopex 17 2 170317 £7.00 RMX connection set DUO25 2 170318 £7.00 RMX connection set Monopex 20 2 170320 £7.00 RMX manifold isolating valves 1” 2 175514 £21.00 HEATING Clamping ring set on RMX heating circuit manifold for flow and return per heating circuit HKV manifold: HKV heating circuit manifold, suitable for underfloor heating and radiators, with fast mounting system. Description Quantity per pack Part number Trade Price Manifold HKV 2-port 1 172502 £75.00 Manifold HKV 3-port 1 172503 £90.00 Manifold HKV 4-port 1 172504 £107.00 Manifold HKV 5-port 1 172505 £121.00 Manifold HKV 6-port 1 172506 £143.00 Manifold HKV 7-port 1 172507 £153.00 Manifold HKV 8-port 1 172508 £169.00 Manifold HKV 9-port 1 172509 £183.00 Manifold HKV 10-port 1 172510 £200.00 Manifold HKV 11-port 1 172511 £215.00 Manifold HKV 12-port 1 172512 £232.00 Manifold HKV 13-port 1 172513 £247.00 Manifold HKV 14-port 1 172514 £303.00 HKV actuator (230V) Actuator for HKV manifold and kombi box 1 175110 £21.00 HKV connection set DUO17 2 177012 £7.00 HKV connection set Monopex 14 2 177014 £7.00 HKV connection set Monopex 17 2 177017 £7.00 HKV connection set DUO25 2 177018 £7.00 HKV connection set Monopex 20 2 177020 £8.00 Connection kit for HKV2 to HKV14 Contains 2 x isolating valves (1”), 2 x connection pieces, 2 x filling and draining valves and 2 x temperature gauges 1 175510 £71.00 Clamping ring set on HKV heating circuit manifold for flow and return, per heating circuit Price List Update: Valid from 1st January 2017 155 Underfloor Heating System Manifold Accessories Quantity per pack Part number Trade Price Coupling nipple (3/4”) for combination with 1703** clamping ring sets 2 177227 £8.00 Connection nipple (3/4” PEX x 1/2” male) for combination with 1703** clamping ring sets 2 177327 £6.00 Manifold cabinet up to 7-port 1 174110 £131.00 Manifold cabinet up to 10-port 1 174115 £145.00 Manifold cabinet up to 14-port 1 174120 £166.00 Kombi box Subdivision for distribution room-by-room and controller for max. 2 underfloor heating circuits with system 70 for DUO 17 heating pipe and optionally with a radiator complete in UP case incl. cover plates, without clamping ring set and actuator 1 172415 £99.00 HEATING Description Underfloor Heating (UFH) System Design Process To prepare an accurate bill of materials and quotation for your underfloor heating project, we need to carry out a detailed UFH system design. This will take account of parameters including room heat losses, water flow temperature, floor construction, floor coverings and preferred manifold positions. 156 Residential, Commercial and Industrial If you require an UFH system design, please contact your sales representative or your local branch for assistance. To enable us to carry out the UFH design, you will need to submit: > Autocad drawings – floor plans and elevations > Completed Daikin UFH design request form (available from your local branch) Please allow up to 20 working days from submitting your drawings to receiving your quotation. Once you have placed an order for the UFH materials, we will send you the UFH system design for your approval prior to shipping the materials. Underfloor Heating System Insulating Strips and Installation Accessories Quantity per pack Part number Trade Price Tacker gun Tacker gun for 60mm pipe staples. The tacker gun can be used to secure pipe directly to floor insulation 1 171134 £208.00 Pipe staples 60mm pipe staples for use with tacker gun (171134) and high density insulation with DPM 300 171137 £36.00 Clip rail 1m pieces, pipe centres 50mm 100 171224 £282.00 Clip rail nail KN06 100 171127 £28.00 Edging strip For cement or anhydrite screed. PE foam with welded foil, height 150mm, 8mm thick 25m 171101 £16.00 Edging strip For free-flowing screed PE foam with welded foil, and additional sealing cord. Height 150mm, 10mm thick 25m 171126 £31.00 Combined pipe cutters and stripping pliers RAZ1 1 171110 £55.00 Pipe decoiler RAW 240 for <240m 1 171006 £546.00 Pipe clips 50 171117 For Ø 17-20mm £6.00 171125 For Ø 25mm £9.00 171142 For Ø 14-18mm £16.00 171143 For Ø 20-22mm £20.00 Pipe bend This is recommended to facilitate the bend of the pipe up-to the manifold HEATING Description 10 Price List Update: Valid from 1st January 2017 157 Underfloor Heating System Underfloor Heating Room Controls Basic Range HEATING Note: Cannot be combined with advanced range (see page 159) Description Quantity per pack Part number Trade Price RTR5 control Electronic room temperature control (230V) 1 175117 £21.00 RTK control Room temperature control with heating/cooling function 1 175125 £31.00 FRT wireless control Wireless room temperature control 1 175120 £80.00 Single FRT wireless receiver Receiver FEM1 for 1x FRT 1 175121 £89.00 Multiple FRT wireless receiver Receiver FEM4 for 4x FRT 1 175122 £158.00 Underfloor Heating System Wiring Centres and Accessories Basic Range Note: Cannot be combined with advanced range (see page 159) Description Quantity per pack Part number Trade Price Wiring box for 14x SAT Wiring box 6xRTR and max 14xSAT DIN rail field supplied 1 175131 £64.00 Wiring box extension for 4x SAT Wiring box extension for 175131. Additional 2xRTR and Max 4x SAT DIN rail field supplied 1 175132 £27.00 Pump module for wiring box Provides on/off signal to the heat source 1 175134 £64.00 Note: Can only be combined with wiring box 175131. One required per UFH manifold DIN rail field supplied 158 Residential, Commercial and Industrial Underfloor Heating System Underfloor Heating Room Controls Advanced Range Modern aesthetics, easy to install and greater user comfort Note: Cannot be combined with basic range (see page 158) Description Quantity per pack Part number Trade Price Room thermostat (wired) - Electronic room temperature control (5V) - Adjustment range 5-26°C - Display of heating and cooling mode (red and blue LED) 1 175139 £28.00 Room thermostat (RF) - Electronic room temperature control - Adjustment range 5-26°C - Solar powered (no batteries required) - Allow 24 hours to charge before commissioning 1 175142 £133.00 Underfloor Heating System Wiring Centres and Accessories Advanced Range Modern aesthetics, easy to install and greater user comfort Description Quantity per pack Part number Trade Price Wiring centre - 6 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover DIN rail field supplied 1 175140 £126.00 Wiring centre - 2 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover DIN rail field supplied 1 175141 £62.00 Wiring centre (RF) - 6 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover - Including antenna for wireless communication DIN rail field supplied 1 175143 £237.00 Wiring centre (RF) - 2 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover - Including antenna for wireless communication DIN rail field supplied 1 175144 £157.00 Wiring centre power module To supply power to the wiring centres, including: - Pump input/output for heating and cooling DIN rail field supplied 1 175137 £118.00 Wiring centre clock module - Removable clock module - 2 setback timers for heating circuits 1 175138 £62.00 Note: To be combined with the wiring centre power module Price List Update: Valid from 1st January 2017 159 HEATING Note: Cannot be combined with basic range (see page 158) HEATING Heat Pump Convectors Heat pump convectors can provide both heating and cooling if required and can be used with the Daikin Altherma heat pump to offer a compact and highly efficient solution: > Designed to operate at low flow temperature (35°C) to optimise the efficiency of an air-to-water heat pump > Quiet operation and no draughts > Able to heat and cool > Available in 1.5 and 2kW 160 Residential, Commercial and Industrial FWX / EKV Daikin Heat Pump Convector Indoor Unit FWXV15A FWXV20A Description Cased, low wall mount type, 2-pipe* Cased, low wall mount type, 2-pipe* EKVKHPC EKVKHPC £511.00 £550.00 1.5 1.2 0.98 0.013 0.013 2.0 1.7 1.4 0.015 0.015 Must be ordered with: Combined Trade Unit Price Heating capacity Cooling capacity Power input Total capacity Nom. Total capacity Nom. Sensible capacity Nom. Heating Nom. Cooling Nom. Height x Width x Depth Dimensions Weight Piping connections Drain/OD/Inlet/Outlet Sound pressure level Heating Nom. Cooling Nom. Power supply Phase/Frequency/Voltage kW kW kW kW kW mm kg mm/inch dBA dBA Hz/V 600 x 700 x 210 15 18/G 1/2/G 1/2 19 19 29 29 1-phase / 230V / 50Hz Features: Notes: > The highly efficient, low noise Daikin heat pump convector is designed to provide the maximum comfort and high efficiency in combination with Daikin Altherma heat pumps > The heat pump convector improves system efficiency compared to a combined under floor heating and radiator system and to a fan coil heating system > The Daikin heat pump convector has been designed to work effectively at low temperatures, while retaining a compact size compared to an equivalent output radiator sized for 45°C > The heat pump convector can easily replace existing heat emitters > The unit is very quiet in operation and is ideal for bedroom applications > The unit has a quiet operation mode which can be selected using the remote controller > The sound levels are as low as 18dB(A) on 2kW system and 12dB(A) on 1.5kW system on the quiet mode > Daikin heat pump convectors offer a solution combined with UFH systems to provide heat in areas where UFH is difficult to integrate > It is designed to support heating only and heating / cooling applications > When combined with Daikin Altherma outdoor units, the heat pump convectors can be linked together for total system control, additional comfort and increased efficiency > Additional third party controls are needed to link simple fan coil systems with Daikin Altherma heat pumps > Delivered with individual controller and with 2-way valve > Drain pan is included i) * Please note that EKVKHPC (2 way valve) needs to be ordered as a separate item, but price shown includes the value of this part Price List Update: Valid from 1st January 2017 HEATING Nominal capacity based on following conditions: Heating: indoor temp, 20°CDB; entering water temp. 45°C, water temperature drop 5°C. Cooling: Indoor temp. 27°CDB; entering water temp. 7°C, water temperature rise 5°C. 161 HEATING Daikin UK Price List Update Refrigeration 164 Indoor Units and Biddle Air Curtains 165 Booster Unit 166 ZEAS 167 Multi-ZEAS 168 Accessories for ZEAS and Conveni-Pack 169 Industrial Condensing Units 170 REFRIGERATION Conveni-Pack (CVP) Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 LRYEQ-AY1 Conveni-Pack (CVP) Conveni-Pack is a compact, low noise system which integrates high and low temperature refrigeration along with heating and cooling into one system. It’s a total solution that helps retailers save energy and reduce their environmental impact. Benefits > Optimum efficiency: inverter driven outdoor units match system output to the actual demand in order to reach optimum efficiency under all conditions > Connection flexibility: supports a wide range of refrigeration and cooling cases > Save energy: by recovering the heat extracted from the connected refrigeration appliances and using sophisticated controls, energy savings of up to 50% can be reached compared with conventional 3P systems > Small footprint: along with reduced piping makes the compact Conveni-Pack ideal for densely populated urban areas > Flexible: VRV (Variable Refrigerant Volume) technology for flexible application range. Full range of VRV fan coils available together with air curtains -35°C HEAT RECOVERY > Minimal noise: lowest operating sound level including night set back function Medium temperature refrigeration & air conditioning REFRIGERATION Cooling capacity Heating capacity (2) Dimensions Weight Heat exchanger Fan Fan motor Sound pressure Compressor Operation range Refrigerant Refrigerant oil Piping connections Power supply Voltage range Air conditioning Refrigeration (1) Air conditioning Refrigeration (2) Height x Width x Depth Type Type Quantity Air flow rate Cooling Output Drive Nom. at 10m free field N° of compressors Type Piston displacement Speed Output Starting method Frequency ON/OFF Evaporator Cooling Type Charge Control Type Charged volume Refrigeration Liquid LRYEQ16AY1 Nom. Nom. Nom. Nom. kW kW kW kW mm kg Nom. m³/sec W dBA m³/h rpm W Min.~Max. 50m or less 50~130m Gas 50m or less 50~130m Phase / Frequency / Voltage Min. Max. -10°C °CDB kg l inch (mm) inch (mm) inch (mm) inch (mm) Hz / V % % 14.0 21.8 27.0 21.8 1,680 x 1,240 x 765 370 Cross fin coil Propeller fan 2 3.833 750 Direct drive 42 3 Hermetically sealed scroll compressor 13.34 / 10.53 / 10.53 6,300 / 2,900 / 2,900 2,500 / 3,600 / 4,500 Direct on line (inverter driven) Less than 6 times/hour -20 @ 0~10 R-410A 11.5 Electronic expansion valve Daphne FVC68D 1.7 (*1) / 2.1 (*2) / 2.1 (*3) / 4.0 (*4) 3/8 (9.5) 1/2 (12.70) 1 1/8 (28.60) 1 3/8 (34.90) 3~ / 50 / 380-415 -10 10 (1) Cooling priority mode: evaporating temp. -10°C; outdoor temp. 32°CDB; suction SH 10°C (2) Heat recovery 100% mode: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; refrigeration load 18kW; piping length: 7.5m; level difference: 0m (*1) Compressor 1 (*2) Compressor 2 (*3) Compressor 3 Trade Price 164 Residential, Commercial and Industrial £14,015.00 (*4) Factory charge of unit Indoor Units and Biddle Air Curtains for Connection to Conveni-Pack To respond to all shop requirements for comfort cooling and heating, a wide range of AC indoor units and Biddle air curtains is available. Capacity class (kW) Product name 50 63 71 80 100 125 140 200 250 5.6 6.3 7.1 8.0 9.0 8.0 9.0 10.0 11.2 12.5 14.0 16.0 16.0 18.0 22.4 25.0 28.0 31.5 Page 56 Page 57 Roundflow cassette FXFQ-A 2-way blow ceiling mounted cassette FXCQ-A 1-way blow corner cassette FXKQ-MA See VRV Section Page 57 Concealed ceiling unit (medium static) FXSQ-A Page 58 Concealed ceiling unit (high static) FXMQ-P7 Page 58 Concealed ceiling unit (ultra high static) FXMQ-MB Ceiling suspended unit FXHQ-A Under ceiling cassette unit FXUQ-A Floor mounted cased FXLQ-P Page 62 Concealed floor standing unit FXNQ-A Page 62 Page 60 Page 61 Page 61 REFRIGERATION Model Cooling capacity (kW)1 Heating capacity (kW)2 Please see Fan Coils on pages 56 to 62 for full product details and prices. Capacity class (kW) Model Product Name Heating capacity (kW)2 80 100 7.4 - 11.0 11.6 - 13.4 125 140 200 250 15.6 16.2 - 19.9 23.3 29.4 - 31.1 See VRV Section Biddle air curtain free hanging CYVS-DK Pages 66 & 67 Biddle air curtain cassette CYVM-DK Pages 66 & 67 Biddle air curtain recessed CYVL-DK Pages 66 & 67 1 Nominal cooling capacities are based on: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB, piping length: 7.5m, level difference: 0m 2 Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB / 6°CWB, piping length: 7.5m, level difference: 0m 3 Optional Price List Update: Valid from 1st January 2017 165 LCBKQ-AV19 Booster Unit Benefits > A booster unit allows the connection of freezer showcases/ rooms to ZEAS and Conveni-Pack outdoor units > R educed piping requirements, from 4 to 2 pipes, compared with a conventional system > Low sound mode reduces sound emissions significantly Booster with ZEAS: MEDIUM + LOW TEMPERATURE refrigeration -19°C -20°C 8°C 2°C Booster Booster Booster with Conveni-Pack: MEDIUM + LOW TEMPERATURE refrigeration + space air conditioning + Biddle air curtain -19°C 8°C 2°C REFRIGERATION Booster Low Temperature Refrigeration Nom. Unit Weight Compressor Unit Type Piston displacement m³/h Number of revolutions rpm Output W Starting method Frequency ON/OFF Type Air flow rate Cooling Nom. m³/min Evaporator Cooling Min.~Max. °CDB Ambient temperature Min.~Max. °C Type Control Type Charged volume l Piping length System Booster unit - IU Phase/Frequency/Voltage Hz/V Operation range Refrigerant Refrigerant oil Piping connections Power supply Booster LCBKQ3AV19 Refrigeration capacity Dimensions Fan -20°C Height Width Depth Trade Price kW mm mm mm kg 3.35 480 680 310 47 Hermetically sealed swing compressor 10.16 6,540 1,300 Direct on line (inverter driven) Less than 6 times/hour Propeller fan 1.6 -45~-20 -15~43 R-410A Electronic expansion valve Daphne FVC50K + FVC68D 0.85 / 0.5 30m or less 1~/50/220-240 £2,773.00 (1) Evaporating temp. -35°C; outdoor temp. 32°C; suction SH 10K; saturated temp. to discharge pressure of booster unit -10°C (2) Its functioning relies on fluorinated greenhouse gases 166 Residential, Commercial and Industrial LREQ-BY1 ZEAS Condensing Units When you select a refrigeration condensing unit, you want premium performance with simple installation and maintenance. That’s why you should specify Daikin ZEAS condensing units. A complete solution for refrigeration applications Its small footprint and low sound levels offer installation flexibility, so you can gain larger capacities even in small spaces. What’s more, the ZEAS solution comes fully packaged and programmed, with minimal pipe work required, so installation time and cost is reduced. Compact yet powerful and extremely energy efficient, Daikin ZEAS condensing units offer an industry-leading solution for all kinds of installation projects. ZEAS is an adaptable and controllable solution for all kinds of environments with fluctuating loads such as supermarkets, hotels, restaurants, hospitals and florists, as well as food production facilities such as cold storage, and blast coolers and freezers. All in all, it’s a quality solution that delivers maximum refrigeration capacity with minimal fuss. Delivering all the benefits of inverter controlled VRV technology for commercial refrigeration systems, ZEAS offers a comprehensive product range suitable for low temperature applications of 5.51 to 15.4 kW at -35/+32°C and medium temperature applications of 12.5 to 37.9 kW at -10°C /+32°C. Medium temperature (Te -10°C Tamb +32°C) Low temperature (Te -35°C Tamb +32°C) Annual Energy Consumption Seasonal Energy Performance Ratio Coefficient Performance (Te -10°C Tamb +32°C) Seasonal Annual Energy Consumption efficiency LOW Seasonal Energy Performance Ratio Temperature Coefficient Performance (Te -35°C Tamb +32°C) Dimensions Unit Height x Width x Depth Weight Unit Heat exchanger Type Fan Type Quantity Air flow rate Cooling Nom. Fan motor Output Drive Sound pressure Nom. at 10m free field Compressor Type Piston displacement Speed Output Starting method Operation range Evaporator Min.~Max. Ambient temp. Min.~Max. Refrigerant Type Charge Control Refrigerant oil Type Charged volume Piping Liquid 50m or less connections 50~130m Gas 50m or less 50~130m Power supply Phase/Frequency/Voltage Voltage range Min. Max. Current Nominal running Compressor Cooling current (RLA) - 50Hz Current - 50Hz Trade Price Starting current (MSC) Minimum Ssc value Minimum circuit amps (MCA) Maximum fuse amps (MFA) Total overcurrent amps (TOCA) Full load amps (FLA) Fan motor > Highly efficient packaged refrigeration condensing units > Low noise mode, reducing noise by a further 5 dBA > Optimum efficiency, Inverter driven compressor and condenser fan motors. LREQ5BY1 LREQ6BY1 kW kW kWh/a SEPR COP kWh/a SEPR COP mm kg 12.5 15.2 5.51 6.51 19,907 24,681 3.86 3.79 2.45 2.32 25,547 29,336 1.61 1.65 1.18 1.11 1,680 x 635 x 765 166 m³/sec kW 1.583 dBA m³/h rpm kW °CDB °C kg l inch (mm) inch (mm) inch (mm) inch (mm) Hz/V % % A A kVa A A A A 1.700 LREQ8BY1 LREQ10BY1 LREQ12BY1 19.8 8.33 33,483 3.64 2.26 36,361 1.71 1.08 23.8 10.0 42,794 3.42 2.25 44,054 1.69 1.08 1,680 x 930 x 765 242 Cross fin coil Propeller fan 26.5 10.7 46,337 3.51 2.21 47,872 1.67 1.08 1 2.850 12.8 13.7 74 655 19.3 15 15.6 0.4 £5,921.00 £7,360.00 £8,855.00 LREQ20BY1 33.9 37.9 13.9 15.4 61,683 72,030 3.38 3.23 2.23 2.23 64,882 71,162 1.60 1.61 1.09 1.09 1,680 x 1,240 x 765 331 337 2 2.983 3.183 0.35 0.75 Direct drive 35.0 36.0 37.0 39.0 41.0 Hermetically sealed scroll compressor 11.18 13.85 19.68 23.36 25.27 5,280 6,540 4,320+2,900 6,060+2,900 6,960+2,900 2.6 3.2 2.1 + 3.6 3.0 + 3.6 3.4 + 3.6 Direct on line (inverter driven) -45~10 -20~43 R-410A 5.2 7.9 Electronic expansion valve Daphne FVC68D 1.7 / 2.5 1.7 / 2.5 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 3/8 (9.5) 3/8 (9.5) 1/2 (12.70) 7/8 (22.20) 1 1/8 (28.60) 7/8 (22.20) 1 1/8 (28.60) 3~/50/380-415 -10 10 7.1 9.2 5.3 + 7.5 7.4 + 7.9 9.8 + 8.3 - LREQ15BY1 3.933 0.35 + 0.35 4.000 0.75+0.75 42.0 43.0 32.24 35.8 5,280+2,900+2,900 6,960+2,900+2,900 2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6 11.5 1.7 / 2.1 / 4.0 1/2 (12.70) 1.7 / 2.1 / 4.0 1 3/8 (34.90) 1 3/8 (34.90) 7.0 + 8.2 + 8.2 75 9.5 + 8.4 + 8.4 84 899 22.0 25 31.5 0.9 1,097 24.0 £10,850.00 £11,570.00 761 31.4 945 35.0 40 48.3 0.4 + 0.4 0.7 + 0.7 £16,531.00 £18,766.00 *Operation conditions of outdoor unit: Te = -10°C, outdoor temperature +32°C, suction SH10°C Price List Update: Valid from 1st January 2017 167 REFRIGERATION MT or LT refrigeration condensing unit Refrigeration capacity Seasonal efficiency MEDIUM Temperature ZEAS condensing units offer: LREQ-BY1 Multi-ZEAS Condensing Units The Multi-ZEAS units deliver the higher capacities required for larger supermarkets, food storage and processing plants, while reducing energy consumption by 35%, compared with traditional refrigeration systems. Multi-ZEAS provides a superior solution to the traditional rack systems typically used for bigger capacities, because the units can be connected easily – in master and slave combination – so installation piping is reduced and installation time is much quicker. The new high capacity Multi-ZEAS consists of two 15hp units or two 20hp units. This system offers the perfect solution for multiple refrigeration needs in supermarkets and for applications with fluctuating loads and high energy efficiency requirements, such as blast coolers and freezers, cold storage, food outlets and restaurants. MT or LT refrigeration condensing unit REFRIGERATION System Refrigeration capacity Medium temperature Nom. Low temperature Nom. Dimensions Unit Height x Width x Depth Weight Unit Heat exchanger Type Compressor Type Piston displacement Speed Output Starting method Fan Type Quantity Air flow rate Cooling Nom. Fan motor Output Drive Sound pressure level Nom. at 10m free field Operation range Evaporator Cooling Min.~Max. Ambient temperature Min.~Max. Refrigerant Type Charge Control Refrigerant oil Type Charged volume Piping Liquid 50m or less connections 50~130m Gas 50m or less 50~130m Power supply Phase/Frequency/Voltage Current Nominal running current (RLA) - 50Hz Current - 50Hz Starting current (MSC) Trade Price 168 Residential, Commercial and Industrial kW kW mm kg ZEAS condensing units are far quieter than traditional units, because inverter control keeps fan speeds low while still meeting cooling demand. At night maximum fan speeds can be lowered to reduce noise, with only a limited loss of refrigeration capacity. The ‘plug and play’ units come fully equipped and do not need to be installed in a plant room, so retail space is maximised. All ZEAS units have optimised controls, which can communicate with a third party monitoring system or building management system via Daikin’s powerful Modbus interface. Servicing and maintenance is also simple. LREQ30BY1 LREQ40BY1 LREQ15BY1R x 2 67.8 27.8 (1,680 x 1,240 x 765) x 2 331 x 2 LREQ20BY1R x 2 75.8 29.6 (1,680 x 1,240 x 765) x 2 337 x 2 Cross fin coil Hermetically sealed scroll compressor m³/h rpm W 32.24 x 2 (5,280+2,900+2,900) x 2 (2.6+3.6+3.6) x 2 35.80 x 2 (6,960+2,900+2,900) x 2 Direct online (inverter driven) Propeller fan m³/sec W 2x2 3.833 x 2 (350 x 2) x 2 2x2 4.000 x 2 (750 x 2) x 2 Direct drive dBA °CDB °C 45.0 46.0 -45~10 -20~43 R-410A 11.5 x 2 Electronic expansion valve Daphne FVC68D (1.7+ 2.1+2.1+ 4.0) x 2 kg l 3/4 (19.05) 1 5/8 (41.28) Hz/V A A 3~/50/380~415 (7.0/8.2/8.2) x 2 (9.5/8.4/8.4) x 2 109 115 £32,814.00 £37,284.00 Accessories for ZEAS and Conveni-Pack BHGP26A1 Digital pressure gauge kit The digital measurement display allows you to diagnose a unit at a glance and it can be used with all ZEAS units and Conveni-Pack systems. > D igital measurement display for fixed installation or service applications > Displays high and low pressure > Displays error codes in the event of a fault > Displays up to 32 operating parameters > Displays error code history (last three) > Scrolls and stores output values > Automatically returns to normal operating display mode Discharge pressure display Suction pressure display BHGP26A1 Part No Description Trade Price BHGP26A1 Digital pressure gauge £320.00 MPa display BRR9A1V1 Modbus communication kit The interface allows you to read all the operational parameters and control important values using the Modbus protocol. This unifying component transforms ZEAS and Conveni-Pack into a transparent, customisable refrigeration unit and means that you can create object-specific and energy-optimised shop concepts, including remote monitoring application. Pro-interfaces can be used to connect up to 32 ZEAS units, and are also suitable for use with Conveni-Pack systems and the Booster. Control values > > > > REFRIGERATION The Daikin Modbus Communication Interface lets you fully integrate Daikin ZEAS and Daikin Conveni-Pack systems with building control automation networks and other monitoring systems. T arget evaporation temperature Low pressure level for on and off points Forced stop Error messages can be cancelled remotely Display values > > > > > > Model information and operating status Refrigerant operating pressure and temperatures Electrical operating data and temperatures for components Target values Fan stage and compressor frequency, operating hours Warning and error messages as well as system safety functions Part No Description Trade Price BRR9A1V1 Modbus communication unit £824.00 BRR9A1V1 Price List Update: Valid from 1st January 2017 169 HSH/M/L 31 - HA Industrial Condensing Units with Screw Compressor Condensing unit for industrial refrigeration REFRIGERATION > High energy efficiency: inverter controlled compressor, economiser, high performance condenser > Possibility of having a stand-by compressor > Easy installation, ready to connect evaporators > Integrated starter and control panel with electronic controller > Space saving construction due to the compact design of the condenser coils arranged in a ‘W’ configuration > Low sound operation > Approved according to EN 378: 2008 (Safety and environmental requirements) > Refrigerants: R-404A, R-134a, R-407C, R-507A Optional > > > > ariable speed inverter technology V Variable condenser fan speed Economiser (sub cooler) Optional standby compressor on single compressor systems > Low sound level unit with sound pressure level 64 dBA at 10 metres. Sound reduction kits can be supplied with lower sound level up to 52 dBA at maximum capacity Width Height mm mm mm Weight kg From 2,240 2,235 2,340 2,405 To 4,940 2,235 2,340 4,496 Performance overview LT Economised 2 compressors LT Economised 1 compressor LT Standard 2 compressors Applications > > > > > > Length LT Standard 1 compressor Cold stores Blast chillers Blast freezers Food processing Food distribution centres Large supermarkets MT Economised 2 compressors MT Economised 1 compressor MT Standard 2 compressors MT Standard 1 compressor 0 50 100 150 200 250 300 350 400 450 Capacity at +32°C in kW Part No Description Trade Price HSH/M/L 31 - HA Industrial condensing unit POA 170 Residential, Commercial and Industrial LT Evaporating T = -35°C MT Evaporating T = -10°C Daikin UK Price List Update Applied Daikin Chillers and Condensing Units 172 Daikin Fan Coil Units 180 Daikin Modular Air Handling Units 190 APPLIED Save energy with Daikin ‘Total Inverter Solutions’ Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 Daikin Chillers Whatever your needs in climate control or process chilling, there is a system that has proved its value in many situations – from factories and warehouses to hotels and department stores, APPLIED and even district cooling for residential applications. Daikin’s ranges of air-cooled and water-cooled chillers are designed to suit every application – large or small – offering the ultimate in flexibility and control. The unique combination of advanced technology, experience and reliability make Daikin chillers the ideal choice. Highest efficiency Daikin chillers have nominal cooling capacities of 5kW to 2,000kW (air-cooled) or 13kW to 2,156kW (water-cooled). > Lowest total cost of ownership Worldwide experience A global leader in HVAC solutions, Daikin has the world’s most advanced facilities for air conditioning research and development, meaning that we can manufacture all main chiller components (compressors, fans, condenser coils, software) in-house. Using the latest technology, Daikin achieves industry-leading efficiency and energy-saving operation for outstanding cost saving performance. > Fast payback time > Environment-friendly solutions Quality, reliability > Zero defect policy ensures quality of components and finished products > A ll chillers factory run and subjected to quality audit before shipment > Eurovent and AHRI certification 172 Residential, Commercial and Industrial High Efficiency Inverter Chiller Ranges High efficiency inverter chiller ranges for comfort and process cooling / heating. Why break from tradition? > Seasonal efficiency > Seasonal quietness > Low starting currents > Flexibility for new build or replacement projects High efficiencies both at full load and part load > F actory leak-tested and pre-charged > High serviceability > User-friendly smart controls which can be integrated easily with building management systems > Daikin compressor with in-built inverter and Variable Volume Ratio (VVR) for optimised efficiency > In-house developed software with dynamic condensing pressure management and innovative economiser control logic Rapid return on investment Benefits for the consultant > Payback of three years, compared to a non-inverter unit for comfort cooling applications > Less than one year for process cooling applications > M ultiple options available, e.g. rapid restart, variable speed water pumps, smart energy meter, EC fans > Ideal for both new and retrofit projects: same footprints of non-inverter unit with higher efficiencies and performance Perfect comfort level Benefits for the end user > R apid payback of three years for comfort cooling applications > 50% reduction of energy consumption > Designed for sound-sensitive environments APPLIED Benefits for the installer > Infinitely variable load regulation > Precise leaving water temperature control thanks to stepless regulation Compact design > More compact heat exchanger with superior efficiencies > Reduced electrical panel dimensions thanks to the inverter compressor mounted. Price List Update: Valid from 1st January 2017 173 Products Overview Air Cooled Chillers and Condensing Units Sound version BPHE EWAQ~G- R-410A 1 BPHE EWAQ~E- R-410A 1 EWAQ~F- R-410A 2 EWAQ~GZ R-410A 1-2 EWAD~E- R-134a 1 EWAD~D- R-134a 2 EWAD~C- R-134a 2-3 EWAD~CZ R-134a 2-3 EWAD~CF R-134a 2 R-134a 1-2 EWYQ~ADVP R-410A 1 EWYQ~ACV3/ACW1 R-410A 1 EWYQ~BA* R-410A 1 SEHVX-AAW SERHQ-AAW1 R-410A 1 BPHE EWYQ~G- R-410A 1 BPHE EWYQ~F- R-410A 1-2 EWYD~BZ R-134a 2-3 R-134a 1 Reduced Low 1 Standard R-410A High ambient EWAQ~BA* Premium High Standard 1 Single pass shell and tube R-410A Plate ** EWAQ~ACV3/ACW1 Screw Scroll 1 Swing R-410A Free cooling EWAQ~ADVP Inverter Refrigerant circuits Efficiency version Extra low Water heat exchanger Refrigerant type * Compressor Cooling only BPHE BPHE POA EWAD~TZ B NEW POA APPLIED Heat pump BPHE BPHE BPHE Condensing unit ERAD~E* (GWP) : R-410A (2087.5), R-134a (1430) ** BPHE: Brazed plate heat exchanger *** Mandatory commissioning by Daikin Airconditioning UK 174 Residential, Commercial and Industrial Mini chillers Air cooled screw chillers Ideal for residential or light commercial applications, Daikin mini chillers are equipped with an inverter swing or scroll compressor allowing a smooth, more reliable and energy-efficient operation with low noise levels and class-leading ESEERs. Manufactured for large capacities, Daikin screw chillers deliver unparalleled reliability and efficiency, both for comfort and process cooling. Equipped with an inverter they provide high efficiency at part load. Air cooled scroll chillers Daikin scroll chillers are designed for small and medium cooling and heating capacities. Our wide range of models matches every building’s air conditioning and process cooling needs. Cooling capacity (kW) Heating capacity (kW) 0 17.5 200 500 1,000 2,000 5.3~7.2 8.6~17.0 16.6~64.5 69.3~154 172~334 *** Mandatory commissioning 165~672 196~395 98~411 177~620 617~2,002 1,166~1,795 602~1,555 170~1,100 0 17.5 200 500 1,000 2,000 500 1,000 2,000 5.3~7.2 5.6~8.2 8.6~17.0 9.9~14.8 16.6~64.5 20.7~74.3 75.2~165 82.2~170 158~624 173~674 247~580 271~618 0 17.5 200 116~488 *** Mandatory commissioning 21.3~63.7 Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk Price List Update: Valid from 1st January 2017 175 APPLIED 16.2~63.7 Products Overview Water Cooled and Condenserless Chillers Sound version Standard Premium High Efficiency version Standard Single pass shell and tube Centrifugal Screw Scroll Inverter Refrigerant circuits Refrigerant type * Plate ** Water heat exchanger Compressor POA Water cooled chillers (Cooling only & Heating only) EWWP~KBW1N R-407C 1-2-4-6 EWHQ~G- R-410A 1 EWWQ~G- R-410A 1 EWWQ~L- R-410A 2 EWWD~J- R-134a 1-2 EWWD~G- R-134a 1-2 EWWD~I- R-134a 1-2-3 EWWD~H- R-134a 1 Flooded R-134a 1-2 Flooded R-410A 1-2 EWLP~KBW1N R-407C 1-2 BPHE EWLQ~G- R-410A 1 EWLQ~L- R-410A 2 EWLD~J- R-134a 1-2 EWLD~G- R-134a 1-2 EWLD~I- R-134a 1-2-3 R-134a 1 EWWD~VZ NEW POA Water cooled chillers (Cooling only) EWWQ~B- Water cooled centrifugal chillers POA APPLIED POA Condenserless chillers EWWD~FZ * (GWP) : R-410A (2087.5), R-134a (1430), R-407C (1,773.9) ** BPHE: Brazed plate heat exchanger *** Mandatory commissioning by Daikin Airconditioning UK 176 Residential, Commercial and Industrial Flooded Water cooled scroll chillers Water cooled, oil free centrifugal chillers These units are among the most efficient, quiet and reliable chillers available today which can be easily integrated with the HVAC system of your choice. With a small footprint, quiet compressor and ability to integrate easily with existing HVAC systems, this chiller is the ideal solution for large cooling requirements (e.g. district cooling) and offers a return on investment throughout its lifecycle. Water cooled screw chillers The Daikin water cooled screw chillers provide the ideal solution for sound sensitive environments. Applications range from comfort cooling to ice making. Cooling capacity (kW) Heating capacity (kW) 0 17.5 200 500 1,000 2,000 12.9~194 16.7~249 87.3~352 107~420 93.7~370 107~426 187~721 *** Mandatory commissioning 213~837 120~568 142~681 165~602 209~743 332~1,503 424~1,951 368~1,212 454~1,488 449~2,068 500~2,300 0 17.5 200 500 1,000 2,000 1,000 2,000 1,000 2,000 379~2,156 0 17.5 200 500 12.1~62.4 110~529 160~524 315~1,433 0 17.5 200 500 113~1,054 Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk Price List Update: Valid from 1st January 2017 177 APPLIED 173~676 *** Mandatory commissioning 86.5~346 Air Cooled Water Chillers Air Cooled Inverter Packaged Swing / Scroll Compressor – R410A c/w Hydraulic Pump and Expansion Vessel Model No Nominal Cooling kW Nominal Heating kW Power Supply EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P 5.20 6.00 7.10 8.60 9.60 11.10 9.10 11.10 13.30 - 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 3-phase 3-phase 3-phase Trade Price EWAQ~P Base Unit EWAQ~P-HBase Unit with OP10 £2,154.00 £2,334.00 £2,564.00 £3,042.00 £3,197.00 £3,406.00 £3,155.00 £3,432.00 £3,612.00 £1,914.00 £2,097.00 £2,324.00 £2,652.00 £2,807.00 £3,016.00 £2,767.00 £3,042.00 £3,222.00 Air Cooled Inverter Packaged Scroll Compressor – R410A Model No Nominal Cooling kW Nominal Heating kW Power Supply EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW***R EWAQ050BAW***R EWAQ064BAW***R 17.40 21.70 25.80 32.30 43.40 51.80 64.50 - 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase Trade Price EWAQ-BAWN Base Unit EWAQ-BAWNBHBase Unit with OP10+OPZL £5,158.00 £5,958.00 £6,637.00 £7,557.00 £9,975.00 £11,018.00 £12,595.00 £4,516.00 £5,316.00 £5,995.00 £6,915.00 £9,146.00 £10,189.00 £11,766.00 EWAQ-BAWPBHStd Pump Unit with OP10+OPZL £5,566.00 £6,365.00 £7,044.00 £8,101.00 £10,519.00 £11,562.00 £13,139.00 EWAQ-BAWHBHHigh Pump Unit with OP10+OPZL £5,756.00 £6,556.00 £7,235.00 £8,155.00 £10,788.00 £11,832.00 £13,408.00 Air Cooled Heat Pump Water Chillers Air Cooled Heat Pump Inverter Packaged Swing / Scroll Compressor – R410A c/w Hydraulic Pump and Expansion Vessel Model No Nominal Cooling kW Nominal Heating kW Power Supply EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P 5.20 6.00 7.10 8.60 9.60 11.10 9.10 11.10 13.30 5.65 6.35 7.75 9.90 11.40 12.90 10.90 12.40 13.90 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 3-phase 3-phase 3-phase Trade Price EWYQ~P Base Unit EWYQ~P-HBase Unit with OP10 £2,450.00 £2,624.00 £2,879.00 £3,442.00 £3,603.00 £3,796.00 £3,561.00 £3,832.00 £4,028.00 £2,209.00 £2,387.00 £2,642.00 £3,052.00 £3,213.00 £3,406.00 £3,171.00 £3,442.00 £3,638.00 APPLIED Air Cooled Heat Pump Inverter Packaged Scroll Compressor – R410A Model No Nominal Cooling kW Nominal Heating kW Power Supply EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW***R EWYQ050BAW***R EWYQ064BAW***R 17.40 21.70 25.80 32.30 43.40 51.80 64.50 16.20 20.30 24.60 30.70 40.60 49.00 61.50 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase Trade Price EWYQ-BAWN Base Unit EWYQ-BAWNBHBase Unit with OP10+OPZL £5,834.00 £6,754.00 £7,536.00 £8,593.00 £11,344.00 £12,544.00 £14,359.00 £5,192.00 £6,113.00 £6,895.00 £7,951.00 £10,515.00 £11,715.00 £13,530.00 Notes: Fitted Options: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk To Fit Model EWAQ-A & EWYQ-A Option Description OP10 Evaporator Heater Tape ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C iii) Nominal heating capacities are based on 7°C db / 6°C wb ambient, water @ 40 / 45°C iv) EWA/YQ-A series only operates in cooling down to ambients of +10°C. EWA/YQ-B series can operate in cooling down to ambients of -5°C standard or -15°C with option OPZL v) The EWA/YQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request vi) Commissioning by Daikin Airconditioning UK is not mandatory, however can be arranged through your regional service department 178 Residential, Commercial and Industrial EWYQ-BAWPBHStd Pump Unit with OP10+OPZL £6,242.00 £7,162.00 £7,944.00 £9,137.00 £11,888.00 £13,088.00 £14,903.00 EWYQ-BAWHBHHigh Pump Unit with OP10+OPZL £6,432.00 £7,352.00 £8,134.00 £9,191.00 £12,157.00 £13,357.00 £15,172.00 EWA/YQ-ADVP 005 006 007 £241 £241 £241 EWA/YQ-ACV3P 009 010 011 £390 £390 £390 EWA/YQ-ACW1P 009 011 013 £390 £390 £390 016 £367 £275 £408 £598 032 £367 £275 £544 £598 064 £462 £367 £544 £813 To Fit Model EWAQ-BA & EWYQ-BA Option Description OP10-D OPZL OPSP OPHP Evaporator Heater Tape Chilled Water Down to -10 Low Lift Pump High Lift Pump 021 £367 £275 £408 £598 025 £367 £275 £408 £598 040 £462 £367 £544 £813 050 £462 £367 £544 £813 Water Cooled Chillers Model No Nominal Cooling kW Nominal Heating kW Power Supply Trade Price To Fit Model EWWP-KAW1N Water Cooled Packaged Scroll Compressor – R407C EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N 12.90 21.40 27.80 32.30 42.80 55.70 64.70 - Fitted Options: 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase £2,507.00 £3,189.00 £3,672.00 £4,111.00 £5,132.00 £6,084.00 £6,746.00 Option Description 014 022 028 035 045 055 065 OPZH OPZL Chilled Water Down to -5 Chilled Water Down to -10 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condenser water @ 30/35°C iii) Commissioning by Daikin Airconditioning UK is not mandatory, however can be arranged through your regional service department Condenserless Chillers Model No Nominal Cooling kW Nominal Heating kW Power Supply Trade Price To Fit Model EWLP-KAW1N Condenserless Packaged Scroll Compressor – R407C EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N 12.10 20.00 26.80 31.20 40.00 53.70 62.40 - Fitted Options: 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase £2,131.00 £2,712.00 £3,120.00 £3,494.00 £4,362.00 £5,172.00 £5,734.00 Option Description 012 020 026 030 040 055 065 OPZH OPZL Chilled Water Down to -5 Chilled Water Down to -10 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 £127 Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condensing temperature @ 45°C, liquid temperature @40°C iii) Commissioning by Daikin Airconditioning UK is not mandatory, however can be arranged through your regional service department Applied Systems Kit Options Model Description Trade Price DTA104A62 EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80 EKAC10C EKRUMCA EKBT EKLS1 EKLS2 EKLS2 X 2 EKRP1HBA EKRP1AHT EKRUAHTB RTD-W EKCC-W External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065 Address card for connection to BMS - EWWP, EWLP (note not available on the modular EWWP) Remote Control - EWWP, EWLP (needs EKAC10C) Buffertank 200I Low noise operation EWLP012~EWWP14 Low noise operation EWLP02~030, EWWP22-35 Low noise operation EWLP040~065, EWWP45-65 Digital I/O PCB - EWAQ / EWYQ - AC Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64) Remote user interface (in parallel) - EWAQ/EWYQ-BA MODBUS Interface - EWAQ/EWYQ-BA Sequence Controller - EWAQ/EWYQ-BA £230.00 £1,735.00 £1,846.00 £1,846.00 £1,922.00 £2,071.00 £2,071.00 £89.00 £170.00 £1,141.00 £161.00 £161.00 £322.00 £108.00 £108.00 £164.00 £214.00 £666.00 APPLIED Loose Accessory Options: Daikin Commissioning & Maintenance Model Description Net Price UK.FSCC/SMALL UK.FSCC/MEDIUM UK.FSCC/LARGE UK.FSCM/SMALL UK.FSCM/MED UK.FSCM/LARGE Commissioning for small size chiller <70kW (price per chiller) Commissioning for medium size chiller 70-999kW (price per chiller) Commissioning for chiller large >1000kW ~ (price per chiller) Maintenance contract for small size chiller <70kW (price per maintenance visit) Maintenance contract for medium size chiller 70-999kW (price per maintenance visit) Maintenance contract for large size chiller >1000kW ~ (price per maintenance visit) £685.00 £877.50 £1,170.00 £342.50 £685.00 £1,027.50 Notes: i) Commissioning is mandatory on all chillers with a nominal capacity >70kW and as indicated on the product overview pages 174-177 Please contact your regional service department for further information on these services. Price List Update: Valid from 1st January 2017 179 Product Overview Fan Coil Units Fan Coil Units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system. These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of Fan Coil Units for both concealed and exposed applications, to suit particular APPLIED installation requirements. Many of these are available with Brushless Direct Current (BLDC) Fan Motors providing high energy efficiency and comfort levels. 180 Residential, Commercial and Industrial High Efficiency BLDC Fan Coil Units High efficiency BLDC Fan Coil units for comfort cooling / heating. Brushless DC Motors for: > Higher operational efficiency > Tighter comfort control > Low sound levels Higher efficiency than AC (Alternative Current) motor Benefits for the installer > R educed amount of sizes: less stock space needed > Modular designs for multiple configurations > E asy integration in BMS system via modbus protocol* * except for FWG-AT/AF range Benefits for the consultant > B est solution in the market in order to have top efficiency,best comfort and lowest sound levels > > > > Up to 70% energy savings No heat generation No power losses Higher efficiency than AC motors to reach set point High comfort level > > > > Less fluctuation of air temperature and relative humidity More consistent output level Stepless speed change for gradual air output More accurate adjustments to reach set point Benefits for the end user APPLIED Low sound levels > Lower minimum rotation speed > No start-stop sequence > Gradual air output > H igh comfort level > Up to 70% savings on running costs > Controller with timer programmed operating mode Price List Update: Valid from 1st January 2017 181 Product Overview Fan Coil Units Type Model Ceiling mounted cassette Floor standing unit Flexi type unit Product name Fan motor type Roundflow cassette - Brushless DC fan motor unit for ceiling mounting - 360° air discharge ensures uniform air flow - Integrated fresh air intake - Easy installation in corners - Standard drain pump with 850 mm lift FWC-BT/BF BLDC 4-way blow ceiling mounted cassette - AC fan motor unit for ceiling mounting - Integrated fresh air intake - Horizontal auto swing - Easy installation in corners - Standard drain pump with 750 mm lift FWF-BT/BF AC Floor standing unit - Brushless DC fan motor for vertical mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels FWZ-AT/AF BLDC Floor standing unit - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance FWV-DAT/DAF AC Flexi type unit - Brushless DC fan motor unit for horizontal or vertical mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels FWR-AT/AF BLDC Flexi type unit - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance FWL-DAT/DAF AC FWS-AT/AF BLDC FWM-DAT/DAF AC Wall mounted unit - AC fan motor unit for wall mounting - High aesthetic cabinet design - Optimum air distribution - Easy installation - 3-speed fan motor FWT-CT AC Concealed ceiling unit with medium ESP - Brushless DC fan motor unit for horizontal concealed mounting - Instant adjustment to temperature and relative humidity changes - Available static pressure up to 80 Pa - Low sound levels FWP-AT BLDC Concealed ceiling unit with medium ESP - AC fan motor unit for horizontal concealed mounting - Available static pressure up to 80 Pa - 7-speed electrical motors (thermal protection on windings) - Easy maintenance FWB-BT AC Concealed ceiling unit with high ESP - Brushless DC fan motor unit for horizontal concealed mounting - Instant adjustment to temperature and relative humidity changes - Available static pressure up to 120Pa - Low sound levels FWN-AT/AF BLDC Concealed ceiling unit with high ESP - AC fan motor unit for horizontal or vertical concealed mounting - Available static pressure up to 120 Pa - Easy maintenance FWD-AT/AF AC Concealed flexi type unit - Brushless DC fan motor unit for horizontal or vertical concealed mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels Concealed flexi type unit - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance Wall mounted unit APPLIED Concealed ceiling unit Capacity conditions EUROVENT conditions Cooling 27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C 182 Heating 4 Pipe 20°C db - Entering water 70°C - Leaving water 60°C Residential, Commercial and Industrial Heating 2 Pipe 20°C db - Entering water 50°C - Flow rate as in cooling mode Capacity class (kW) 1 2 3 4 5 Cooling: 2.0 - 5.2 kW Heating: 2.9 - 6.7 kW 6 7 8 9 10 Cooling: 2.49 - 4.54 kW Heating: 3.52 - 5.28 kW Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW Cooling: 2.43 - 5.28 kW Heating: 3.22 - 7.33 kW Cooling: 2.61 - 6.47 kW Heating: 5.47 - 12.28 kW Cooling: 2.61 - 10.34 kW Heating: 5.47 - 18.78 kW Cooling: 3.91 - 8.75 kW Heating: 4.48 - 9.07 kW Cooling: 3.90 - 18.30 kW Heating: 4.05 - 21.92 kW Cooling: 1.46 - 8.02 kW Heating: 1.90 - 10.03 kW Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW Cooling: 1.46 - 8.02 kW Heating: 1.90 - 10.03 kW Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW Cooling: 1.46 - 8.02 kW Heating: 1.90 - 10.03 kW 11 12 ~ 18 APPLIED Capacity Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk TYPICAL UK cooling conditions 22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C 0 Pa External Static Pressure 0% Glycol FWP & FWD Ducted FCU - Above capacities are based on 30 Pa External Static Pressure FWS Uncased - Based on 20 pa external static Price List Update: Valid from 1st January 2017 183 New BLDC (Brushless Direct Current) Inverter Driven Floor Standing Fan Coil Units Cased Low Wall Mount Type 2-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch FWZ06AT FWZ08AT 2.57 4.96 6.40 226 x 987 x 564 25 70/28 62/20 15.00 1/2 3.23 6.32 7.51 226 x 1194 x 564 31 64/28 56/20 20.00 1/2 5.11 10.08 11.18 251 x 1404 x 564 41 71/28 63/20 27.66 3/4 FWZ02ATN £265.00 FWZ02ATT6V3ES£530.00 FWZ02ATV6V3ES£601.00 FWZ03ATN £280.00 FWZ03ATT6V3ES£553.00 FWZ03ATV6V3ES£622.00 FWZ06ATN £324.00 FWZ06ATT6V3ES£605.00 FWZ06ATV6V3ES£680.00 FWZ08ATN £405.00 FWZ08ATT6V3ES£691.00 FWZ08ATV6V3ES£773.00 FWZ02AF FWZ03AF FWZ06AF FWZ08AF 1.39 2.64 2.46 226 x 774 x 564 21 62/28 54/20 9.33 1/2 2.57 4.96 4.19 226 x 987 x 564 26 70/28 62/20 15.00 1/2 3.23 6.32 6.45 226 x 1194 x 564 33 64/28 56/20 20.00 1/2 5.11 10.08 10.06 251 x 1404 x 564 44 71/28 63/20 27.66 3/4 FWZ06AFN £363.00 FWZ06AFT6V3-S£516.00 FWZ06AFV6V3-S£634.00 FWZ08AFN £446.00 FWZ08AFT6V3-S£602.00 FWZ08AFV6V3-S£726.00 1ph Trade Fan Coil Price - Complete with 2-way 230V valve, Elec Heater & FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve, Elec Heater & FWECSAP power control factory fitted Cased Low Wall Mount Type 4-pipe Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data FWZ03AT 1.39 2.64 3.47 226 x 774 x 564 20 62/28 54/20 9.33 1/2 Power Supply Trade Fan Coil Price - Naked - No Valve Capacity FWZ02AT UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch Power Supply 1ph Trade Fan Coil Price - Naked - No Valve Trade Fan Coil Price - Complete with 2-way 230V valve and FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve and FWECSAP power control factory fitted FWZ02AFN £289.00 FWZ02AFT6V3-S£441.00 FWZ02AFV6V3-S£559.00 FWZ03AFN £306.00 FWZ03AFT6V3-S£459.00 FWZ03AFV6V3-S£577.00 Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network New BLDC (Brushless Direct Current) Inverter Driven Flexi Fan Coil Units Cased Flexi Type 2-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch APPLIED FWR06AT FWR08AT 2.57 4.96 6.40 226 x 987 x 564 27 70/28 62/20 15.00 1/2 3.23 6.32 7.51 226 x 1194 x 564 33 64/28 56/20 20.00 1/2 5.11 10.08 11.18 251 x 1404 x 564 44 71/28 63/20 27.66 3/4 FWR02ATN £277.00 FWR02ATT6V3ES£542.00 FWR02ATV6V3ES£613.00 FWR03ATN £300.00 FWR03ATT6V3ES£572.00 FWR03ATV6V3ES£642.00 FWR06ATN £346.00 FWR06ATT6V3ES£627.00 FWR06ATV6V3ES£701.00 FWR08ATN £441.00 FWR08ATT6V3ES£727.00 FWR08ATV6V3ES£810.00 FWR02AF FWR03AF FWR06AF FWR08AF 1.39 2.64 2.46 226 x 774 x 564 22 62/28 54/20 9.33 1/2 2.57 4.96 4.19 226 x 987 x 564 28 70/28 62/20 15.00 1/2 3.23 6.32 6.45 226 x 1194 x 564 35 64/28 56/20 20.00 1/2 5.11 10.08 10.06 251 x 1404 x 564 46 71/28 63/20 27.66 3/4 FWR06AFN £383.00 FWR06AFT6V3-S£536.00 FWR06AFV6V3-S£654.00 FWR08AFN £487.00 FWR08AFT6V3-S£643.00 FWR08AFV6V3-S£768.00 1ph Trade Fan Coil Price - complete with 2-way 230V valve, Elec Heater & FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve, Elec Heater & FWECSAP power control factory fitted Cased Flexi Type 4-pipe Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data FWR03AT 1.39 2.64 3.47 226 x 774 x 564 21 62/28 54/20 9.33 1/2 Power Supply Trade Fan Coil Price - Naked - No Valve Capacity FWR02AT UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch Power Supply Trade Fan Coil Price - Naked - No Valve Trade Fan Coil Price - Complete with 2-way 230V valve and FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve and FWECSAP power control factory fitted 1ph FWR02AFN £303.00 FWR02AFT6V3-S£456.00 FWR02AFV6V3-S£574.00 FWR03AFN £326.00 FWR03AFT6V3-S£479.00 FWR03AFV6V3-S£596.00 Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network 184 Residential, Commercial and Industrial New BLDC (Brushless Direct Current) Inverter Driven Low Static Concealed Flexi Fan Coil Units Concealed Flexi Type 2-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch FWS02AT FWS03AT FWS06AT FWS08AT 1.08 2.64 3.47 224 x 584 x 535 15 62/28 54/20 9.33 1/2 2.02 4.96 6.40 224 x 794 x 535 19 70/28 62/20 15.00 1/2 2.52 6.32 7.51 224 x 1004 x 535 23 64/28 56/20 20.00 1/2 3.99 10.08 11.18 249 x 1214 x 535 32 71/28 63/20 27.66 3/4 Power Supply 1ph Trade Fan Coil Price - Naked - No Valve Trade Fan Coil Price - complete with 2-way 230V valve, Elec Heater & FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve, Elec Heater & FWECSAP power control factory fitted FWS02ATN £238.00 FWS02ATT6V3ES£503.00 FWS02ATV6V3ES£574.00 FWS03ATN £253.00 FWS03ATT6V3ES£526.00 FWS03ATV6V3ES£595.00 FWS06ATN £292.00 FWS06ATT6V3ES£572.00 FWS06ATV6V3ES£647.00 FWS08ATN £363.00 FWS08ATT6V3ES£649.00 FWS08ATV6V3ES£732.00 FWS02AF FWS03AF FWS06AF FWS08AF 1.08 2.64 2.46 224 x 584 x 535 16 62/28 54/20 9.33 1/2 2.02 4.96 4.19 224 x 794 x 535 20 70/28 62/20 15.00 1/2 2.52 6.32 6.45 224 x 1004 x 535 25 64/28 56/20 20.00 1/2 3.99 10.08 10.06 249 x 1214 x 535 34 71/28 63/20 27.66 3/4 FWS06AFN £326.00 FWS06AFT6V3-S£479.00 FWS06AFV6V3-S£596.00 FWS08AFN £407.00 FWS08AFT6V3-S£563.00 FWS08AFV6V3-S£688.00 Concealed Flexi Type 4-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height x Width x Depth High/Low High/Low High kW kW kW mm kg dBA dBA m3/min inch Power Supply Trade Fan Coil Price - Naked - No Valve Trade Fan Coil Price - Complete with 2-way 230V valve and FWECSAP power control factory fitted Trade Fan Coil Price - Complete with 3-way 230V valve and FWECSAP power control factory fitted 1ph FWS02AFN £263.00 FWS02AFT6V3-S£415.00 FWS02AFV6V3-S£533.00 FWS03AFN £284.00 FWS03AFT6V3-S£437.00 FWS03AFV6V3-S£555.00 Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network Floor Standing and Flexi Fan Coil Unit Accessories Loose Accessory Options: 4-pipe 3-way 230V on/off valve kits c/w lockshields Vertical drainpan Horizontal drainpan Advanced Plus Electronic Controller Split Electronic Controller Power control board + Control panel On board installation kit (FWZ & FWR - Low Wall Mounted Only) Return Air Sensor 02-03 06 E2MV03A6 £127.00 E4MV03A6 £228.00 EDPVB6 £5.00 EDPHB6 £5.00 FWEC3A £119.00 FWECSA = FWECSAP + FWECSAC £148.00 or £85.00 + £63.00 FWECKA £11.00 FWTSKA £8.00 08 E2MV10A6 £134.00 E4MV10A6 £241.00 i) Each controller version includes the water probe ii) The on board installation kit includes a remote air probe (if installed the internal fan coil probe is disabled) iii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required) iv) The FWECSA can operate up to 256 fan coils as master slave control on RS485 network APPLIED FWZ, FWR, FWS 2-pipe 3-way 230V on/off valve kits c/w lockshields Notes: v) The FWECSAP and FWECSAC can be ordered individually or as a pack Price List Update: Valid from 1st January 2017 185 New BLDC (Brushless Direct Current) Inverter Driven Medium Static Ducted Fan Coil Units Concealed Ducted Type 2-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High kW kW kW mm mm mm kg dBA dBA m3/min inch FWP02AT FWP03AT FWP04AT FWP05AT FWP06AT FWP07AT 1.34 2.61 5.47 239 1039 609 24 56/40 44/24 6.66 3/4 1.67 3.14 6.01 239 1039 609 26 56/40 44/24 6.66 3/4 2.03 3.49 6.47 239 1039 609 28 56/40 44/24 6.66 3/4 2.50 5.08 10.31 239 1389 609 33 61/39 50/27 13.33 3/4 2.77 5.45 11.39 239 1389 609 35 61/39 50/27 13.33 3/4 3.47 6.47 12.28 239 1389 609 38 61/39 50/27 13.33 3/4 Power Supply Trade Fan Coil Price - Naked - No Valve Trade Fan Coil Price - Complete with 3-way 230V valve and FWECSAP power control factory fitted 1ph FWP02ATN FWP03ATN FWP04ATN FWP05ATN FWP06ATN FWP07ATN £341.00 FWP02ATV6V3-S- £355.00 FWP03ATV6V3-S- £369.00 FWP04ATV6V3-S- £432.00 FWP05ATV6V3-S- £437.00 FWP06ATV6V3-S- £466.00 FWP07ATV6V3-S- £491.00 £506.00 £519.00 £584.00 £588.00 £618.00 Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network. If you require a 4 pipe fan coil please purchase additional heat exchanger as shown below Loose Accessory Options: FWP Additional Heat exchanger (4 Pipe) nominal heating cap 3.2kW Additional Heat exchanger (4 Pipe) nominal heating cap 6.1kW 2-way 230V on/off valve cooling coil 3-way 230V on/off valve add.h/e 2-way 230V on/off valve add.h/e Advanced Plus Electronic Controller Split Electronic Controller Power control board + Control panel APPLIED Return Air Sensor 186 Residential, Commercial and Industrial Notes: 02 - 04 05 - 07 EAH04A6 £94.00 - EAH07A6 £109.00 E2MV207A6 £55.00 E2MV307A6 £97.00 E2MV207A6 £55.00 FWEC3A £119.00 FWECSA = FWECSAP + FWECSAC £148.00 or £85.00 + £63.00 FWTSKA £8.00 i) Each controller version includes the water probe ii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required) iii) The FWECSA can operate up to 256 fan coils as master slave control on RS485 network iv) The FWECSAP and FWECSAC can be ordered individually or as a pack New BLDC (Brushless Direct Current) High Static Ducted Fan Coil Units Concealed Ducted Type 2-pipe Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data FWN06AAT FWN07AAT FWN08AAT FWN10AAT 2.25 4.65 5.79 280 754 559 33.3 66/54 52/40 13.20 3/4 3.15 6.02 7.67 280 964 559 40.6 69/59 55/48 20.68 3/4 2.90 6.66 8.65 280 964 559 41.7 69/61 55/47 20.10 3/4 3.96 7.58 9.46 280 1174 559 47.3 72/62 58/48 26.82 3/4 4.33 8.50 10.70 280 1174 559 48.7 72/62 58/48 26.40 3/4 1ph Concealed Ducted Type 4-pipe Dimensions FWN05AAT 2.01 3.80 4.85 280 754 559 32.5 66/54 52/40 13.37 3/4 Power Supply Trade Fan Coil Price Capacity FWN04AAT kW kW kW mm mm mm kg dBA dBA m3/min inch UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High £399.00 £429.00 £715.00 £757.00 £782.00 £819.00 FWN04AAF FWN05AAF FWN06AAF FWN07AAF FWN08AAF FWN10AAF 2.01 2.76 4.48 280 754 559 34.7 66/54 52/40 13.23 3/4 2.25 3.60 4.45 280 754 559 35.5 66/54 52/40 13.07 3/4 3.15 4.54 6.53 280 964 559 43.2 69/61 55/47 20.17 3/4 2.90 5.17 6.44 280 964 559 44.3 69/59 55/48 19.65 3/4 3.96 5.22 9.13 280 1174 559 50.3 72/62 58/48 26.22 3/4 4.33 6.12 9.07 280 1174 559 51.7 72/62 58/48 25.83 3/4 £815.00 £856.00 £903.00 kW kW kW mm mm mm kg dBA dBA m3/min inch Power Supply Trade Fan Coil Price 1ph £450.00 £492.00 £777.00 Loose Accessory Options: 4-pipe 3-way valve Vertical Drain pan Horizontal Drain Pan Advanced Plus Electronic Controller Split Electronic Controller Power control board + Control panel Return Air Sensor 04-05 ED2MV04A6 £133.00 ED4MV04A6 £257.00 06-07 08-10 ED2MV10A6 £133.00 ED4MV10A6 £257.00 EDDPV10A6 £11.00 EDDPH10A7 £13.00 FWEC3A £119.00 FWECSA = FWECSAP + FWECSAC £148.00 or £85.00 + £63.00 FWTSKA £8.00 i) Each controller version includes the water probe ii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required) iii) The FWECSA can operate up to 256 fan coils as master slave control on RS485 network iv) The FWECSAP and FWECSAC can be ordered individually or as a pack APPLIED FWN 2-pipe 3-way valve Notes: Price List Update: Valid from 1st January 2017 187 AC Fan Motor - 3 speed 600 Sq Cassette Fan Coil Units 600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B3 Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High kW kW kW mm mm mm kg dBA dBA m3/min inch 600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B3 Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data FWF03BT FWF04BT FWF05BT 1.20 2.00 2.90 260 575 575 19 44/36 31/26 7.9 1.90 3.20 4.00 260 575 575 19 44/36 31/26 7.9 2.50 4.20 5.40 260 575 575 19 50/36 40/26 11.2 3.10 5.20 6.70 260 575 575 19 55/42 45/30 14.9 3/4 “ BSP Female 1 ph Power Supply Trade Fan Coil Price Capacity FWF02BT UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High kW kW kW mm mm mm kg dBA dBA m3/min inch £575.00 £602.00 £626.00 £650.00 FWF02BF FWF03BF FWF04BF FWF05BF 1.10 2.00 3.90 260 575 575 19 44/36 31/26 7.9 1.60 2.70 3.80 260 575 575 20 44/36 31/26 7.2 2.00 3.50 4.90 260 575 575 20 50/36 40/26 10.4 2.50 4.50 6.10 260 575 575 20 55/42 45/30 13.9 3/4 “ BSP Female 1 ph Power Supply Trade Fan Coil Price £610.00 £640.00 £661.00 £682.00 FWC06BT FWC07BT FWC08BT FWC09BT 3.30 5.80 8.00 288 840 840 26 43/31 29/21 17.7 4.10 6.80 8.90 288 840 840 26 47/33 33/22 20.6 4.30 7.70 10.60 288 840 840 26 53/36 39/24 25.4 4.80 8.70 12.10 288 840 840 26 57/40 43/28 30.8 BLDC Fan Motor - 3 speed Cassette Fan Coil Units Cassette Type 2-pipe c/w Decoration Panel BYCQ140C Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High kW kW kW mm mm mm kg dBA dBA m3/min inch Trade Fan Coil Price APPLIED Cassette Type 4-pipe c/w Decoration Panel BYCQ140C Capacity Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High kW kW kW mm mm mm kg dBA dBA m3/min inch £632.00 £664.00 £692.00 £722.00 FWC06BF FWC07BF FWC08BF FWC09BF 3.30 5.80 7.50 288 840 840 29 43/31 29/21 17.1 4.00 6.60 8.40 288 840 840 29 47/33 33/22 19.9 4.30 7.60 9.70 288 840 840 29 53/36 39/24 24.6 4.80 8.70 11.00 288 840 840 29 57/40 43/28 29 £823.00 £853.00 3/4 “ BSP Female 1 ph Power Supply Trade Fan Coil Price 188 3/4 “ BSP Female 1 ph Power Supply Residential, Commercial and Industrial £753.00 £794.00 Cassette Accessories Loose Accessory Options: Notes: FWF/FWC FWF/FWC FWC only FWC only Remote wired controller BRC315D £66.00 DCS601C51 £1,707.00 KRP4A53 £70.00 KRP4A53/UK.FB2 £96.00 KRP2A52 £184.00 KRP2A52/UK.FB2 £211.00 EKFCMBCB £56.00 EKMV2C09B £60.00 EKMV3C09B £64.00 EKRP1C11 £104.00 Wireless remote control heat pump BRC7FA532F £158.00 BRC7F533F £126.00 KRCS01-4 £42.00 KRP1H98 £38.00 Intelligent touch controller Unit/Group adapter pcb Unit/Group adapter pcb complete with installation box System adaptor pcb System adaptor pcb complete with installation box Optional pcb for connection to ModBus (2 stopbit) 2-Way 230V on/off valve kit 3-Way 230V on/off valve kit Valve control PCB Wireless remote control cooling only Remote air sensor Installation box for an EKRP1C11 valve PCB FWF only FWF only Wireless remote control heat pump BRC7E530 £126.00 BRC7E531 £126.00 KRCS01-1 £48.00 EKRORO £16.00 KRP1BA101 £47.00 Wireless remote control cooling only Remote air sensor Remote on/off control interface kit Installation box for an EKRP1C11 valve PCB i) FWF and FWC Cassette Fan Coil prices include decoration panel ii) It is not possible to use Intelligent Touch control for combination with both VRV and water based fan coils FWF-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 FWC-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 AC Fan Motor - 3 speed Wall Mounted Fan Coil Units Dimensions Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High kW kW kW mm mm mm kg dBA dBA m3/min inch FWT02CT FWT03CT FWT04CT FWT05CT FWT06CT 1.59 2.43 3.22 288 800 206 10 45/36 34/25 7.36 1/2 1.67 2.70 3.52 288 800 206 10 48/39 35/25 7.93 1/2 2.10 3.31 4.40 288 800 206 10 55/45 42/32 10.48 1/2 1ph 2.90 4.54 6.01 310 1065 224 15 55/47 42/34 14.43 1/2 3.41 5.28 7.33 310 1065 224 15 59/51 42/39 17.55 1/2 £200.00 £207.00 £238.00 £288.00 £306.00 Power Supply Trade Fan Coil Price Loose Accessory Options: FWT Standard wired remote controller Simplified wired remote controller Wireless controller for heat pump Notes: FWT MERCA £77.00 SRC-HPA £39.00 WRC-HPC £15.00 i) FWT fan coils are optimised for valveless control in cooling. We would recommend that a valve is fitted if being used for heating only and for more precise control in cooling. ii) We would recommend the field supply of a 240V - 4 port 3 way valve complete with 240V actuator. Price List Update: Valid from 1st January 2017 189 APPLIED Cased High Wall Mount Type 2-pipe Capacity Daikin Air Handling Units Daikin air handling units, with their plug-and-play design and inherent flexibility, can be configured and combined specifically to meet the exact requirements of any building, no matter what it is used for, or who is to work there. Our systems are designed to be the most environmentally friendly and the most energy efficient on the market, thus reducing their ecological impact, APPLIED while, at the same time, keeping costs down through the minimisation of energy consumption. When combined with the small physical footprint of the system, these features make our air handling units ideal for all markets. 190 Residential, Commercial and Industrial ADT-F/B Air Handling Units Modular AHU with high efficiency heat recovery Energy efficiency and indoor air quality > > > > > > Predefined sizes IE4 premium efficiency motor High efficiency heat wheel (heat recovery) Compact design Advanced control features Easy installation EC fan > Air flow or pressure control (Variable Air Volume – Constant Air Volume) > Nominal air flow programmed at factory > Indoor air quality compliant with VDI 6022 hygiene guideline > Silent operation > O perating limits from -25 °C, -40 °C with electric heaters, up to +46 °C ambient temperature Simple, quick installation > VRV IV and ERQ coupling capability > Indoor and outdoor versions > Free cooling capability The Modular series’ Plug & Play design is more than just a convenient feature for installers. It offers cost-saving benefits as there is no need for expensive adjustments before the unit is commissioned. Plug & Play makes everyone’s life simpler, safer and more economical. > Economy and Night mode operation > Monitoring and control through Daikin ITM Main Unit Nominal Performances (Main Module) Size Airflow [m3/s] Temp efficiency winter [%] ESP nominal [Pa] Current nominal [A] Power input nominal [kW] SFPv [kW/m3/s] Electrical supply [V-ph-Hz] Lenght [mm] Depth [mm] Height overall [mm] Weight [kg] Sound level - Lp dB(A)* 1 2 0.33 81.30 200 2.66 0.62 1.87 230-1-50 1700 720 1320 325 40 0.47 81.10 200 3.90 0.89 1.89 230-1-50 1700 820 1320 350 42 3 4 5 6 7 8 9 10 0.75 1.14 1.53 1.69 1.94 2.53 3.19 4.17 81.40 81.60 82.60 81.20 82.70 81.40 81.50 83.20 200 200 200 200 200 200 200 200 6.30 2.98 4.00 4.74 4.76 5.54 8.72 10.20 1.50 1.98 2.68 2.96 3.30 3.76 5.48 7.04 1.99 1.74 1.75 1.75 1.70 1.49 1.72 1.69 230-1-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 1800 1920 2080 2280 2400 2450 2280 2400 990 1200 1400 1400 1600 1940 1940 2300 1540 1740 1740 1920 1920 2180 2460 2570 475 575 750 790 950 1330 1410 1750 42 45 46 44 43 43 45 45 * Sound pressure level radiated from unit at 1 meter and according to ISO 3744 (supply outlet ducted) Main Unit Size 1 Main Module 2 3 4 5 6 7 8 9 10 £7,518.00 £7,787.00 £8,752.00 £9,610.00 £10,469.00 £11,153.00 £12,347.00 £14,389.00 £16,518.00 £18,509.00 * Price includes G4/G7 filtration, Mineral Wool Insulation, Aluzinc internal skin and Aluzinc or Pre-Painted external skin Mode Coil Module Mixing Box Roof Frost Coil (Elec - 2 stage) Chilled Water Cooling Coil Chilled Water Cooling+LPHW Heating Coil DX Heat Pump (Cooling/Heating) Coil’s Row 6 6+2 4 Size Three way mixing box Size Outdoor Kit (Roof ) Size Filter Stage Heat Wheel M6 Filter (to replace G3 or G4) Additional Filtration Module F9 front withdrawal Size Sorption Type (to replace sensible type on main module) Coms Module Size Bacnet Module (for ITM Daikin) Acoustic Module Size Single Silencer Module Double Silencer Module 1 2 3 4 5 6 £1,354.00 £1,185.00 £1,689.00 £1,489.00 £1,449.00 £1,302.00 £1,820.00 £1,540.00 £1,550.00 £1,530.00 £2,084.00 £1,692.00 £1,627.00 £1,826.00 £2,498.00 £2,526.00 £1,737.00 £2,059.00 £2,768.00 £2,641.00 7 8 9 10 £1,847.00 £1,995.00 £2,174.00 £2,392.00 £2,654.00 £2,473.00 £2,142.00 £2,792.00 £3,018.00 £3,500.00 £3,222.00 £2,928.00 £3,671.00 £3,620.00 £5,009.00 £2,836.00 - 1 2 3 4 5 6 7 £631.00 £641.00 £688.00 £780.00 £829.00 £853.00 £986.00 8 9 10 £1,123.00 £1,222.00 £1,328.00 1 2 3 4 5 6 7 8 9 10 £151.00 £166.00 £202.00 £256.00 £329.00 £346.00 £382.00 £465.00 £494.00 £555.00 3 4 5 6 7 8 9 10 1 2 £82.00 £831.00 £82.00 £855.00 1 2 £723.00 £821.00 1 2 £139.00 £164.00 £220.00 £220.00 £246.00 £393.00 £393.00 £526.00 £1,002.00 £1,162.00 £1,281.00 £1,400.00 £1,632.00 £1,927.00 £2,258.00 £2,399.00 3 4 5 6 7 8 9 10 £1,038.00 £1,372.00 £1,565.00 £1,683.00 £2,014.00 £2,287.00 £2,733.00 £3,743.00 3 4 5 6 7 8 9 10 £164.00 1 2 3 4 5 6 7 8 9 10 £621.00 £682.00 £722.00 £839.00 £914.00 £992.00 £1,093.00 £1,297.00 £1,327.00 £1,455.00 £1,179.00 £1,294.00 £1,371.00 £1,593.00 £1,735.00 £1,884.00 £2,077.00 £2,462.00 £2,521.00 £2,764.00 Note: Final pricing will be dependent on actual selection configuration, unit construction and additional modules required. Above pricing will provide a sufficiently accurate indication for budget purposes Please contact your local sales office for further information on selection at different working conditions and matched Daikin ERQ & VRV IV condenser units for DX applications Price List Update: Valid from 1st January 2017 191 APPLIED Size Air Handling Units Modular AHU application with Daikin DX condensers Daikin fresh air package High comfort levels The Daikin fresh air package provides a complete solution, including all unit controls (expansion valve, control box an AHU controller) and sensors factory mounted and configured. Daikin ERQ and VRV units respond rapidly to fluctuations in supply air temperature, resulting in a steady indoor temperature and resultant high comfort levels for the end user. The ultimate is the VRV range which improves comfort even more by offering continuous heating, also during defrost. This unique solution allows for plug and play connection of our AHU series to Daikin ERQ and VRV condensing units. High efficiency Daikin heat pumps are renowned for their high energy efficiency. Integrating the AHU with a heat recovery system is even more effective since an office system can frequently be in cooling mode while the outdoor air is too cold to be brought inside in an unconditioned state. In this case heat from the offices is merely transferred to heat up the cold incoming fresh air. VRV IV or ERQ condensing unit Expansion kit factory fitted and integral to DX HP coil module APPLIED Expansion valve (EKEXV) Please refer to pricing of our VRV IV (pages 71 - 73 and pages 76 - 83 and page 95) and ERQ (Page 52) inverter driven condensing unit ranges which are compatible with the Modular AHU. 192 Residential, Commercial and Industrial Electronic interface (EKEQ) Daikin UK Price List Update Delivery Information 194 Goods Returns Procedure 195 Service Department 196 Daikin Service Tools 199 Training 200 Terms & Conditions 202 Scottish Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355 SERVICES & TRAINING Services & Training NEW PRICING Delivery Information Delivery Type Time New Pricing Order processing Deadline Notes: Standard Delivery - Weekday (excluding Spares) Next Day Delivery 08:00 - 17:00 Free of Charge Order processed by 14.00 the previous working day >W eekday hours: Monday - Friday 08:00 - 17:00 Timed Delivery - weekday (excluding Spares) Before 13:00 After 12:30 Time specific normal hours Time specific out of hours Sameday (geographical restrictions apply) > O ut of Hours: before 08:00 or after 17:00 £50.00 £45.00 £220.00 £390.00 £220.00 Order processed by 14.00 the previous working day Order processed by 14.00 the previous working day Requires two working days’ notice Requires two working days' notice Order processed by 11:00 07:00 - 18:00 08:00 - 17:00 - £390.00 £35.00 £110.00 Variable Requires two working days’ notice Requires two working days’ notice Requires two working days’ notice Requests processed on an individual basis Online orders Next Day Delivery <20Kg Next Day Delivery >20Kg Before 13:00 Weekend Deliveries 07:00 - 18:00 07:00 - 18:00 07:00 - 18:00 07:00 - 13:00 Free of Charge £7.50 £60.00 £90.00 Orders received by 14:00 previous working day Orders received by 14:00 previous working day Orders received by 14:00 previous working day Orders received by 14:00 previous working day Saturday Delivery <20kg Saturday Delivery >20kg 07:00 - 18:00 07:00 - 18:00 £35.00 £60.00 Orders received by 14:00 previous working day Orders received by 14:00 previous working day - From £390.00 From £390.00 From £390.00 From £390.00 Requires two working days’ notice Requires two working days’ notice Requires two working days’ notice Requires two working days’ notice Weekend Deliveries Saturday /Sunday time specific Saturday Delivery <15kg Saturday Delivery >15kg Public Holidays 08:00 - 13:00 12:30 - 17:00 Between 08:00 - 17:00 Before 08:00 & after 17:00 Spare Parts Delivery Service Next Day Delivery - Weekday Special Vehicle - Weekday / Weekend Hiab: kerbside drop FORS (fleet operator recognition scheme) Flat Bed Two man delivery service * Information available from your local Daikin Sales Order Support team. > 9 8% of UK mainland postcodes are covered under the Next Day delivery service > S tandard delivery will normally be made by a single driver on an 18T rigid lorry equipped with tail lift and pump truck. Alternative sized vehicles maybe utilised from time to time. If you face site restriction at your nominated delivery address and a vehicle other than an 18T rigid lorry is required, notification is needed two working days prior to delivery > N ext day delivery is subject to postcode restrictions, full details of delivery areas can be obtained from the business portal on my.daikin.co.uk (deliveries to Scotland, Off shore UK Islands, Northern Ireland and the ROI may be subject to 2 to 5 day delivery routes) > T ime specific deliveries are +/- 30 minutes from the requested time > H iab pricing (vehicle with lifting arm) is based on kerbside drop. Deliveries requiring further lifting capabilities or outside of normal hours (08:00 - 17:00) may incur additional charges. Prices can be requested at time of order > T wo man deliveries can be requested for heavier items and deliveries above ground level > D elivery address, site contact name and number are required for every delivery SERVICES & TRAINING > O ur drivers are not permitted to make part delivery against a delivery note. Additional charges may apply for refused deliveries 194 Residential, Commercial and Industrial Goods Returns Procedure Daikin UK policy for acceptable returned goods Goods returns timescales What happens next Daikin UK allows returned goods within the following timescales: Once the Goods Return Form is received, an email will be sent to the confirmation email address provided notifying you of the goods for collection and a date for this to be carried out. If you have any queries regarding this date please respond to the email address provided as soon as possible. Units & accessories: 10 working days from date of invoice Spare Parts: 1 month from date of invoice Within these timescales, Daikin may accept unwanted goods provided they are boxed in the original packaging, in perfect condition and have not been used. Arranging goods returns Once inspected and confirmation is received that the goods are in perfect condition, a credit will be raised against the original invoice. *Please note returns for chillers and made to order units will not be accepted* To arrange the process of returning goods, please complete a Goods Returns Form available from my.daikin.co.uk and fax or email: Goods covered by warranty Units & Accessories: Fax: 0845 641 9150 or email: returns@daikin.co.uk Once a unit has been installed and commissioned, any faults or breakdowns that occur should be reported to our warranty department on: Spare Parts: Fax: 0845 641 9299 or email: spares@daikin.co.uk Telephone: 0845 641 9275 or email: warranty@daikin.co.uk Conditions of returned goods All returned items are subject to a minimum 20% restocking/ administration charge with the following collection charges applied to the final credit: Collected goods up to 15KG: £15 Collected goods over 16KG: £90 All returned goods will be fully inspected by our technical engineers. If returned goods are in a non-satisfactory condition then Daikin reserves the right to decline the return or apply an increase to the restocking charge. Damaged items Daikin will only accept claims for damages when the goods have been signed for as damaged on the delivery note and you have notified Daikin Returns Team within three working days of delivery. If you identify damage at point of delivery, you are entitled to refuse the delivery and contact us to arrange for a new unit to be sent out. Price List Update: Valid from 1st January 2017 195 SERVICES & TRAINING If after unpacking the units, you identify damage, claims must be reported within three working days from the delivery date to Daikin Returns Team along with photographs of the damage. The Daikin UK Service Department The Daikin UK Service department supplies a range of services to support our customers. Pre-installation, commissioning and project support Workshop Commissioning In our workshop in Bristol we modify standard Daikin equipment to current specifications in order to meet our clients’ needs. We can offer bespoke modifications to suit your exact requirements – please speak to your sales engineer to discuss how we can help you. Daikin UK offers a full commissioning service, which includes the charging of additional refrigerant, setting up of all Daikin control systems, operation testing and validation. A detailed commissioning report is produced per system to aid you with handover of the project. If you require dedicated support throughout your project, we can now offer an extended service to meet all your project requirements. Typical modifications include: > C reating weather-proof enclosures for VAM Total Heat Exchangers. See page 111 > Repainting indoor and outdoor units. For VRV units, see page 69, for Sky units see page 41 > Customisation of controls > Removing flare connections > Strip and rebuilds. See page 69 > Blygolding. See below. Strip and rebuild Strip and rebuild offers the benefit of time and cost savings by having VRV outdoor units delivered to site in portable components, so they can be transported to the roof without the need for cranes and road closure applications. Dedicated project support For larger projects, Daikin UK Service department offers complete Project Support from the point of order to system handover. Our service engineers will assist you throughout the project, providing a dedicated contact for technical queries and support, installation checks and commissioning. As part of our Project Support service, we conduct surveys during the installation to ensure it is installed to our specification and rules, witness the strength/pressure test on the DX side, evacuate the systems, charge with any additional refrigerant and configure any ITM controls prior to commissioning. For more information, see page 69. Prior to project commencement, our service engineer will meet with you to: Blygold treatment for heat exchangers iscuss project time scales and schedule Daikin UK > D engineer attendances > Discuss potential installation restrictions/issues > Identify potential issues and give advice on how to avoid > Source copies of the site drawings Daikin UK can offer additional treatment for Heat Exchangers to protect against corrosion and pollution, ensuring the long term efficiency of the units. We can apply a Blygold treatment to the coil and fins. This is recommended for salt laden air (coastal) projects or areas in which high levels of pollutants can create a barrier between the air and the heat exchanger. Lead time: 2-3 weeks Applicable units: All Condensers Unit Split Unit SkyAir 71-140 Class SkyAir 200-250 class VRV Outdoor Treatment Price (Excludes Unit Price) £490.00 £540.00 £610.00 £725.00 Our service engineer will liaise with you throughout the project to agree sign off dates, commissioning dates and schedules. We will then commission the system, ensuring all systems are operating correctly according to the site requirements. Upon completion, a commissioning booklet is produced including: > Installation Certification Reports – number of reports depends on number of checks > Pressure/Strength Test Certificate > Evacuation Verification Certificate > Commissioning Reports > F-Gas Log SERVICES & TRAINING If you would like Daikin UK Project Support, please speak to your sales engineer who will liaise with service management team to assign you a dedicated service engineer. 196 Residential, Commercial and Industrial Post-installation, spare parts and service support Aftersales technical helpdesk Spare parts This invaluable service offers technical support and guidance when you are experiencing on-site problems when commissioning or diagnosing faults. Final diagnosis is the responsibility of the site engineer. When a component fails, Daikin has over 13,000 spare parts based in the UK, supported by our European parts centre with 700,000 parts. This helps us to achieve our target of delivering 97% of critical A parts within two days. For support with Air Conditioning systems, please contact: Tel 0845 641 9200 Mon - Fri 8.30 - 17.30 For support with Heating systems, please contact: Tel 0845 641 9277 Mon - Fri 8.30 - 20.00 & Sat 9.00 - 15.00 Email technicalhelp@daikin.co.uk SMS Fault Code Service 07797 801908 If you need an explanation and remedy on a fault code and haven’t got your service manual, just send the fault code to our SMS message service and we will advise you by return. Maintenance contracts Commercial customers: if you would like Daikin UK to support you with commercial maintenance contracts, we can offer a full service package, including 24 hour support, for account holding customers. Domestic heating customers: Daikin UK offers comprehensive heat pump maintenance as a premium after care service for Daikin Altherma systems. All parts, labour and call-outs are covered in the unlikely event of a heating or hot water failure.* For total comfort and peace of mind, this heat pump maintenance package also includes an annual maintenance visit, to help keep your customers’ systems running efficiently throughout the year and minimise the risk of any breakdowns. Daikin UK also offers a basic heat pump maintenance package, which entitles you to an annual maintenance visit, during which our engineer will ensure that your Altherma heat pump is operating within the optimum conditions to maximise energy efficiency. Any potential issue can be dealt with by a Daikin engineer. You will also be entitled to a discount on the cost of spare parts and labour. To contact the Spares team directly Tel 0845 641 9230 Fax 0845 641 9299 Email spares@daikin.co.uk If you hold a direct account with Daikin UK, you can send and view your spare parts orders online using our Spare Parts Bank – available 24 hours a day, 365 days a year. Plus, there are no delivery charges on orders placed via the Spare Parts Bank, which is equivalent to almost 5% extra discount. To register for Spare Parts Bank go to www.daikin.co.uk/spares Service support on-site We can provide service engineers to assist you with on-site commissioning or service support. All work is documented in a report and sent for your records. So that we can give you the best service possible, it is important to ensure that you are in attendance at that time. To book an engineer, please contact the Regional Service office closest to the site where your equipment is installed: Eastern Region Service Centre Phone number 0845 641 9274 Operating Hours Mon - Fri: 09.00 to 17.00 Email address weybridgeservice@daikin.co.uk Western Region Service Centre Phone number Operating Hours 0845 641 9278 Mon - Fri: 09.00 to 17.00 Email address bristolservice@daikin.co.uk Northern Region Service Centre Phone number Operating Hours 0845 641 9279 Mon - Fri: 09.00 to 17.00 Email address glasgowservice@daikin.co.uk Energy monitoring and auditing Daikin UK offers an increasing range of energy monitoring and auditing services, plus remote monitoring and prediction solutions (DNSS). Please ask your sales engineer if you have a project that you think may be suitable for including in an energy monitoring and auditing trial. *subject to t&c’s Price List Update: Valid from 1st January 2017 197 SERVICES & TRAINING Your calls will be answered by Daikin trained engineers. To help provide a quick and efficient response, please make sure you have the full model number of the unit. It is important to remind you that using the D1/D1+ PIN number gives you priority access to our engineers. Daikin UK warranties Making a warranty claim Daikin UK offers a range of warranties and extended warranties for our Air Conditioning, Applied, Refrigeration and Heating equipment. If you have a component failure and it is within the warranty period then we are here to help. After you have spoken to our Technical Helpdesk to confirm diagnosis, you can simply contact the warranty team. Our warranties have been designed to meet the needs of our customers and, as such, offer different terms for customers belonging to our D1 partner programme, KEY heating installer scheme and customers belonging to neither D1 nor KEY. Our KEY heating installer scheme offers end-user warranties for our domestic heating customers. Please see key.daikin.co.uk for more information. For all other customers - whether D1, D1+ or not yet a D1 partner – we offer a commercial warranty. From April 2016, commercial warranties are held between the installing contractor and Daikin UK only (non transferable). SERVICES & TRAINING For detail on our warranties and how to claim, please see www.daikin.co.uk or visit our business portal my.daikin.co.uk for more information. 198 Residential, Commercial and Industrial Contact the warranty team on: Tel 0845 641 9275 Fax 0845 641 9299 Email warranty@daikin.co.uk Daikin Service Tools Daikin Service App Service checker (part no. 999165T) The Daikin Service Application supports service engineers working with Daikin VRV Equipment. The service checker type 3 can read and record the operational data from various Daikin equipment. This data consists of thermistor readings, pressure sensor values, solenoid valve operation, expansion valve pulses, operation modes etc. Software version 1.53 or later is required for connection to VRV IV systems. It’s available for both android and iPhone devices. The application covers various functions to help field engineers to fault-find Daikin VRV equipment . Service App functions include: Android functions Fault Codes VRV Additional Charge Calculation Replacement PCB Dip Switch Settings Pressure Transducer and Temperature Thermistor Checks Outdoor Unit field settings include: Fan Coil and BSVQ Box Count Check Refrigerant Recovery Setting Outdoor Unit Emergency Modes VRV III & IV Short Test Run There is also Daikin Altherma support for: Fault Codes Additional Refrigerant Charges C Series Altherma Field Settings Dip Switch Settings and much more... iPhone functions Fault Codes VRV Additional Charge Calculation Replacement PCB Dip Switch Settings Pressure Transducer and Temperature Thermistor Checks Outdoor Unit field settings include: Fan Coil and BSVQ Box Count Check Refrigerant Recovery Setting Outdoor Unit Emergency Modes VRV III Short Test Run DChecker The DChecker is a service tool used to capture operational data from the following equipment, Split-Multisplit, Sky-Air & Altherma products. This will record and graph all sensor data, PCB inputs & outputs from indoor and outdoor units. From the operational data this will help to identify any operational issue. Please note the DChecker is a USB interface which provides a direct wired link to the main PCBS and enables real-time data to be viewed on a laptop running windows. Software included. Inverter analyser RS UK0917A (part no. 136 8521) The inverter analyser can be used to check the inverter outputs on all VRV models (can also be used on various Split & Sky Air units). To download the Apps go to: Android: https://play.google.com/store/apps/details?id=com.daikin. aircon&hl=en Price List Update: Valid from 1st January 2017 199 SERVICES & TRAINING iPhone: https://itunes.apple.com/us/app/daikin-service/id571282882?mt=8 Daikin UK’s Customer Training During 2016 we will continue to further invest in all our regional training centres, hands-on training facilities and online resources, to ensure that the training you receive is relevant to the everchanging market. By doing so, we aim to help you provide your customers with the highest quality Installation, commissioning, maintenance, service and fault-finding support. Leading the way in R32 and R410A training Daikin UK training centres New hands-on training rigs for R410A or R32 Split systems are now situated in all Daikin UK training centres. Purpose built R410A Sky Air product training rigs can also be found at both our Woking and Birmingham centres from March 2016. Attendees on our training courses will get the opportunity to improve their operational product knowledge and practice fault finding hands-on. 1 Bristol Daikin Airconditioning UK Limited Maple House, Brotherswood Court, Great Park Road, Almondsbury, Bristol BS32 4QW With the introduction of R32 products into the UK market, and the popularity of R32 training courses to date, we will be investing further in our Woking Technology Centre during 2016, so that we can offer hands-on R32 product installation and commissioning courses. New Birmingham training centre 2 Woking Daikin Airconditioning UK Limited 21 Woking Business Park, Albert Drive, Woking, Surrey GU21 5JY 3 Birmingham Daikin Airconditioning UK Limited 2470 Regents Court, The Crescent, Birmingham Business Park, Birmingham B37 7YE 4 Manchester Daikin Airconditioning UK Limited 17b Cobra Court, Blackmore Road, Manchester M32 0QY 5 Glasgow Daikin Airconditioning UK Limited Unit 2, Glasgow Airport Business Park, Marchburn Drive, Paisley PA3 2SJ 6 PGL Training Clyst Works, Clyst Road, Topsham, Exeter EX3 0DB Adjacent to our new Birmingham sales office, the Birmingham training centre covers an area of over 200m2 and provides hands on training on the latest Split, VRV, Altherma and control systems. Woking Technology Centre The Technology Centre in Woking is Daikin’s largest training facility in the UK, over two floors, covering an area close to 1000m2. The facility is able to hold three training events at one time, with additional equipment demonstration facilities and a dedicated suite for conducting Web based live training events. SERVICES & TRAINING The centre includes VRV Heat Recovery, VRV Heat Pump, Water Cooled VRV, R22 Replacement VRV-Q, as well as a variety of Split and Sky Air systems. A specially designed controls section has been constructed to demonstrate the many different configuration possibilities of individual and central controls together with the many BMS interface options. The first floor is dedicated to Heating products with eight individual working bays containing a wide selection of systems to allow for practical hands-on training of commissioning and fault diagnosis. The award winning Altherma Hybrid system is installed in each of these eight bays, so every attendee receives the highest quality product training experience. To find out when courses are scheduled at regional Daikin UK regional training centres and at PGL Training, check availability and book a place: please go to the Daikin UK booking web site at www.daikintraining.co.uk 200 Residential, Commercial and Industrial Online short courses For anyone operating in the HVACR market, the skills and knowledge required is getting greater every year. Daikin UK recognises our training needs to keep pace with the demands on people working in the industry – not least the pressures on your time. So we are continually looking at new and innovative ways to deliver the training you need. During 2016 we are introducing a wider range of courses, together with new web based short courses available on whichever online or mobile platform you prefer. Within our new Woking Technology Centre we have installed a web based broadcast facility. From here we can provide short courses across a range of subjects. The majority of these will also be recorded and made available through our training website. In response to valued customer feed back, we will also be introducing short online refresher courses on specific products, where previous product course attendance pre-requisites have been fulfilled. Users can register as an individual to undertake web based training and each user has a training account that enables them to review past training they have undertaken and print off training records and certificates. As these courses become available it will be possible to reserve places at www.daikintraining.co.uk. We will announce more specific details throughout the year. Price List Update: Valid from 1st January 2017 201 SERVICES & TRAINING Our new courses will cover more application and design subjects, legislation, technical topics and also personal development areas such as presentation and selling skills. Smith Brothers Stores Ltd Terms and Conditions of Sale 1. Definitions :- 7. a) “the Company” means Smith Brothers Stores Ltd a) Delivery periods are given in good faith and are based from the date of receipt of order. Whilst we will make every reasonable effort to meet delivery requirements we will not be liable for any failure to do so, nor for any consequential loss of any kind arising from late delivery. b) “the Purchaser” means the person, firm or company placing an order on the Company. c) “Quotation” means any Quotation or terms given by the Company. 2. Orders :- No orders placed by the Purchaser arising as a result of a Quotation, Terms or otherwise will be considered as binding on the Company unless that order has been acknowledged by the Company in writing. 3. Effect of Conditions :- All orders accepted by the Company will be subject to the Conditions of Sale set out herein. The Company is not willing to contact otherwise than on these Conditions and unless otherwise expressly agreed in writing these Conditions shall apply to all contracts made between the Company and the Purchaser and any documents emanating from the Purchaser which contain printed or standard Conditions which have been or shall be sent by the Purchaser and received by the Company on the understanding that they appear on the Purchasers documents because they are printed thereon will have no legal effect whatsoever and the Purchaser waives any right which he otherwise might have to rely on such conditions. 4. Validity of Offer :- a) Any prices and/or discounts quoted by the Company, whether verbally or written, will be considered to have a validity of not exceeding 30 days unless otherwise agreed by the Company in writing. b) If the Purchaser intends to place an order with the Company subject to the terms of a nominated or other sub-contract the prices and terms in the tender will not be binding on the Company unless the Purchaser has fully disclosed to the Company such items and conditions of the said sub-contract and that the Company has acknowledged the same in writing. c) If the Purchaser intends that the price for the goods should be paid to the Company by a third party (i.e. a Finance Company or similar institution) it must state on the order that it has received written confirmation from the third party that it will make payment to the Company in accordance with the terms of Clause 8 hereof and if it fails to do so, the Purchaser will be bound to make such payments. 5. Prices :- Unless otherwise agreed in writing the price to be paid will be deemed to have been stated in the Quotation provided that the Quotation is accepted within 30 days of issue and delivery is effected within a further 14 days. Otherwise, the Company may, at its discretion, vary the price by addition upwards to reflect market conditions, labour, material and transportation costs. All prices exclude VAT unless otherwise stated. SERVICES & TRAINING 6. Specifications :- Whilst all descriptions, specifications, drawings and illustrations are supplied in good faith they are only intended for guidance purposes and the Company will accept no responsibility whatsoever for any errors, omissions, loss or damage from the Purchasers reliance on such descriptions, drawings and illustrations. Further, the Company reserves the right to amend such descriptions, specifications, drawings and illustrations without notice. The Company provides no warranty, and it shall not be implied, whether through any description or other-wise, that any Goods conform to or are suitable for any specific purpose, unless written confirmation of such a warranty as to suitability of the goods for purpose addresses specific goods and the Purchaser. The Company may recommend to the Purchaser, specific Goods. These recommendations are based solely upon the information received by the Company from the Purchaser. Therefore, any recommendations by the Company to the Purchaser in relation to any Goods shall be provided only as an opinion, and shall not be construed as an express or implied warranty as to any recommendation given, unless written confirmation of a warranty to that effect is provided by the Company to the Purchaser and the Purchaser is referred to the clause immediately preceding this. The suitability of specific goods for use is ultimately the decision of the Purchaser based solely upon the knowledge of the Purchaser. 202 Residential, Commercial and Industrial Delivery :- b) Deliveries will be made to the destination specified on your order provided this is clearly indicated. c) Unless otherwise agreed the cost of carriage will be chargeable to the Purchaser. Where the Purchaser requests the Company to deliver goods within a timescale which is shorter than that covered by the Company’s quoted delivery costs then the Company reserves the right to vary the price by addition upwards to reflect additional costs incurred. d) Unless otherwise agreed the off loading and safe storage of delivered goods are the sole responsibility of the Purchaser. Where the Purchaser requests the Company to provide off-loading facilities then such facilities will be deemed to be chargeable to reflect the additional costs incurred. e) After delivery the goods are expressly held by the Purchaser at his own risk. The Purchaser undertakes, following delivery to maintain the goods in the pre-delivery condition and to insure the goods to their full value and against all risks until such time as payment and the title passes. f ) The Company reserves the right to levy additional charges against the Purchaser, to cover storage, fire insurance or other costs incurred by us, in the event that the goods are held beyond reasonable period of time or should forward instructions to be withheld. 8. Terms of Payment :- a) Unless otherwise agreed in writing, and only for approved accounts, all goods will be invoiced on despatch for payment at the end of month following the date of invoice. b) Where an approved account is not established or where the total order value, excluding delivery, is less than £50.00 then, at its discretion, the Company may seek payment prior to delivery. c) Time for payment shall be of the essence of the contract without prejudice to any other rights of the Company. If the Purchaser fails to pay the invoice on the due date, the Purchaser shall pay interest on any overdue amount from the date on which payment was due to that which payment was made (whether before or after judgement) on a daily basis of 4% per annum over the base rate quoted from time to time by the National Westminster Bank plc and reimburse to the Company an administration fee of £20.00 together with all costs and expenses, including legal costs, in the collection of any overdue amount. 9. Passing of Property and Risk :- The risk in the Goods shall pass to the Purchaser on completion of delivery. Title to the Goods shall not pass to the Purchaser until the Company has received payment in full (in cash or cleared funds) for: a) the Goods; and b) any other Goods that the Company has supplied to the Purchaser in respect of which payment has become due. Until title to the Goods has passed to the Purchaser, the Purchaser shall: a) hold the Goods on a fiduciary basis as bailee for the Company; b) store the Goods separately from all other goods held by the purchaser so that they remain readily identifiable as the Company’s property; c) not remove, deface or obscure any identifying mark or packaging relating to the Company; d) maintain the Goods in satisfactory condition and keep them insured against all risks for their full price from the date of delivery; e) notify the Company immediately if it becomes subject to the service of a Statutory Demand or any other action involved in the insolvency of the Purchaser; and f ) give the Company such information relating to the Goods as the Company may require from time to time. The Purchaser may resell or use the Goods in the ordinary course of its business. If before title to the Goods passes to the Purchaser the Purchaser is served with a Statutory Demand or any other action involved in the insolvency of the Purchaser, or the Company reasonably believes that any such event is about to happen and notifies the Purchaser accordingly then provided that the Goods haven not been resold and without limiting any other right or remedy the Company may have, the Company may at any time require the Purchaser to deliver up the Goods and, if the Purchaser fails to do so promptly, enter any premises of the Purchaser or of any third party where the Goods are stored/located in order to recover them. 10. Loss and Damage in Transit :a) It is the responsibility of the Purchaser to examine the Goods immediately on arrival and any shortage or damage be reported to us and to the carriers within 3 days of receipt. b) Non delivery of Goods must be reported to us within 10 days of the despatch dates given on the advice note. c) The Purchaser will be liable to indemnify the Company for any loss it suffers where it is unable to claim against the carriers by reason of non-fulfilment of these Conditions. 11. Returned Goods :Any Goods returned to the Company for any reason other than faulty condition will only be accepted with the prior written agreement of the Company. a) Where such agreement exists then the Purchaser will be responsible for the cost of safe packing and delivery of Goods including adequate insurance against damage and loss. b) Where such Goods are returned to the Company by agreement and provided that the Goods are received in a condition which is consistent with the condition on despatch then a credit will be issued to the value of the returned Goods less any restocking charge of not less than 15% of the invoice value of the Goods subsequently returned. 14. Guarantee :a) The Company extends to the Purchaser the terms of warranty, guarantee and conditions that it has, in turn received from the manufacturer. Provided that all amounts due in accordance with clause 8 hereof have been received by the Company. b) All guarantees and warranties are subject to the equipment having been stored, installed, commissioned and maintained in accordance with good practice and the manufacturer’s recommendations. c) To facilitate prompt replacement of any item or component we will despatch parts at the Purchaser’s request on a chargeable basis. When the defective item is returned to us and provided that the fault has been verified under the terms of the guarantee then the invoice will be credited or cancelled. Where no such item or component is subsequently returned within a reasonable period then the Company reserves the right to seek payment for the goods supplied. d) The Company explicitly excludes any labour, consequential or other costs associated with the replacement of Goods, items or components under the terms of the guarantee. 15. Exclusion of Liability :Clause 14 is intended to provide a fair means of resolving disputes about the quality of Goods supplied, and except as provided therein the Company is not liable for any loss or damage, whether consequential or otherwise, howsoever arising out of a contract for the supply of Goods to the Purchaser governed by these Conditions (except for damages for death or personal injury caused by negligence for which the Company is responsible) and all conditions or warranties which might be implied by law are hereby excluded. The Purchaser shall be responsible for ensuring that all Goods subsequently installed on the Purchaser’s premises or elsewhere do not contravene existing laws and regulations and are approved by the Purchaser’s insurers. 16. Force Majeure :Any delay or failure of performance in executing our obligations shall not be determined as a fault or give rise to any claim for lock-outs, restriction of supplies, breakdown of plant or machinery, shortage of labour, war, riots, civil unrest or any other circumstances reasonably beyond our control. 12. Fitness for Purpose :- 17. Law and Jurisdiction :- The Purchaser is solely responsible for suitability of the Goods for which they are bought and is reliant upon his own skill and judgement in this respect. These Conditions shall be subject to English Law and the exclusive jurisdiction of the English Courts. 13. Representation :Registered Office: Batten Street, Aylestone Road, Leicester. LE2 7PB A Member of the Smith Brothers (Leicester) Limited Group of Companies Registration No 962846 Price List Update: Valid from 1st January 2017 203 SERVICES & TRAINING Any statements or claims made by the Company, it representatives, distributors and agents either prior to or during the course of executing a contract between the Purchaser and the Company are superseded by the Conditions herein and as such they are not material. SERVICES & TRAINING Notes 204 Residential, Commercial and Industrial Smith Brothers Stores Ltd SBS is one of the oldest and largest independent merchants operating from within the U.K. directly focusing on supplying to the commercial and industrial mechanical services sector. The core business has specialised in the distribution of pipework, valves and all associated fittings for over 100 years. In recent years we were appointed as a Daikin partner dealer and we have complemented this with an extensive air conditioning ancillary range of products. Currently operating from eleven branches, along with a separate Head Office in Leicester, more are planned for the very near future. SBS should be the number one choice for the mechanical services air conditioning contractor who relies on quality of service combined with competitive pricing. With 100 years of experience, comes expertise and credibility. Conditions Capacity Conditions Unit cooling and heating capacities shown within this price list are based on the following conditions: Nominal cooling Ambient = 35°C Internal = 27°C db 19°C wb Nominal heating Ambient = 7°C db 6°C wb Internal = 20°C db Seasonal Efficiency Split and Sky Air Systems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency UK cooling Ambient = 30°C Internal = 22°C db 16°C wb For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year. Heat Source VRV (ESEER) Unless otherwise indicated, all units within this price list are air-cooled. This digital price book update reflects the planned +4% price increase, as communicated to customers in our letter dated 1 October 2016. Please note that, in order to keep our pricing simple, we have rounded to the nearest pound, therefore the exact price increase may be fractionally different to +4% on individual items. ESEER is defined as the European Seasonal Energy Efficiency Ratio and is a measure of the performance of the outdoor unit only. Nominal Efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP. Nominal Efficiencies are used for systems above 12kW. It is not possible to compare Nominal and Seasonal Efficiency ratings due to the different calculation methods used. Smith Brothers Stores Ltd Suppliers to Building Services Head Office & Accounts Unit V2 Winchester Avenue, Blaby, Leicester, LE8 4GZ Tel: 0116 222 7330 Fax: 0116 222 7331 email: head.office@sbs.co.uk Branch Locations Bristol Leeds Unit 1 Alpha Park, Units 9/10 Cala Trading Estate, Unit 1 Quantum Business Park, Bevan Way, Smethwick, Ashton Vale Road, Pontefract Road, Stourton, West Midlands, B66 1BZ Bristol, BS3 2HA Leeds, LS10 1AX Tel: 0121 555 1900 Tel: 0117 947 1111 Tel: 0113 201 4222 Fax: 0121 555 1901 Fax: 0117 947 1122 Fax: 0113 201 4223 email: birmingham@sbs.co.uk email: bristol@sbs.co.uk email: leeds@sbs.co.uk Leicester London Northampton 99 Commercial Square, Units 3 & 4 Eurocourt, Unit 3 Reynoldston Close, Freemans Common Industrial Estate, Oliver Close, West Thurrock, Brackmills Industrial Estate, Leicester, LE2 7SR Essex, RM20 3EE Northampton, NN4 7BX Tel: 0116 222 7355 Tel: 01708 689 900 Tel: 01604 763 621 Fax: 0116 244 0430 Fax: 01708 689 901 Fax: 01604 760 903 email: leicester@sbs.co.uk email: london@sbs.co.uk email: northampton@sbs.co.uk Oldham Peterborough Southampton Unit N Oldham Central Trading Park Empson Road Unit 3 St Georges Industrial Estate Coulton Close Eastern Industry Goodwood Road, Boyatt Wood Oldham OL1 4EB Peterborough PE1 5UP Eastleigh SO50 4NT Tel: 0161 621 6288 Tel: 01733 311 711 Tel: 02380 623 070 Fax: 0161 621 6289 Fax: 01733 345 293 Fax: 02380 614 320 email: oldham@sbs.co.uk email: peterborough@sbs.co.uk email: southampton@sbs.co.uk Cardiff Heathrow Unit 2 Dominions Way Industrial Unit 2 Pier Road, Estate, Newport Road, Feltham, Greater London, Cardiff, CF24 1RF TW14 0TW Tel: 02921 671 250 Tel: 0203 8565 620 Fax: 02921 671 251 email: cardiff@sbs.co.uk Registered Office: Batten Street, Aylestone Road, Leicester. LE2 7PB A Member of the Smith Brothers (Leicester) Limited Group of Companies Registration No 962846 Fax: 0203 8565 630 email: heathrow@sbs.co.uk Daikin UK Price List Update: Valid from 1st January 2017 Birmingham Daikin UK Price List R3ON2EVETNS Update: Valid from 1st January 2017 I NOWRE SPL TED M O S E L E C I TS N AND AIR U SKY TOO Residential, Commercial and Industrial
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Create Date : 2016:11:24 14:14:24Z Creator : Adobe InDesign CC 2017 (Macintosh) Modify Date : 2016:11:29 16:54:03Z Has XFA : No Language : en-GB XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2016:11:29 16:54:03Z Creator Tool : Adobe InDesign CC 2017 (Macintosh) Instance ID : uuid:a0959e27-3630-401b-b2ea-ae4c70115fda Original Document ID : xmp.did:F77F117407206811A961B78468994EA9 Document ID : xmp.id:37a8dce1-c550-49af-a069-7219008ff8c8 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:e93e96b3-e97b-4e14-8393-67aa2a6fffcf Derived From Document ID : xmp.did:faea987d-830d-4ecc-85f3-420ef3c69e61 Derived From Original Document ID: xmp.did:F77F117407206811A961B78468994EA9 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Macintosh) History Changed : / History When : 2016:11:24 14:14:24Z Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : TwoPageRight Page Count : 208EXIF Metadata provided by EXIF.tools