PTM - LOADGARD
Series
USER MANUAL

Rev. 5.9
Aug 20 2015

HELM INSTRUMENT CO., INC.
1

LIMITED WARRANTY
Helm Instrument Co., Inc. (”HELM”) hereby warrants that the instruments and sensors
(collectively the ”Product”) manufactured by it and sold to customer, are free from
defects in material and/or workmanship under normal use subject to the following
conditions. This warranty shall not apply to any Product which has been subjected to
improper installation, misuse, negligence, accident, alteration, where service has been
performed by other than an authorized Helm serviceman, or where the serial number
has been defaced or altered. This warranty shall extend for the one (1) year period from
date of shipment from our factory or authorized dealer, provided that the product is
returned, freight prepaid, to Helm within the one (1) year warranty period within specific
written authorization to perform repairs. Helm’s obligations and the exclusive remedy of
customer under this warranty are limited to repairing or replacing any defective Product
at no additional charge and returning Product to customer freight paid. Repair parts and
replacement Products shall be furnished on an exchange basis and shall be either new
or reconditioned. All replaced parts and Products shall become the property of Helm.
EXCEPT AS SPECIFICALLY STATED HEREIN, HELM MAKES NO WARRANTIES
EXPRESSED OF IMPLIED, OF THIS PRODUCT INCLUDING BUT NO LIMITED TO
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, OR AS TO THE QUALITY, UTILITY OR PERFORMANCE, ALL QF WHICH
ARE HEREBY EXPRESSLY EXCLUDED. IN NO EVENT SHALL THE LIABILITY OF
HELM EXCEED THE PURCHASE PRICE OF THIS PRODUCT. NOR SHALL HELM BE
LIABLE FOR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL CHARGES, EXPENSE OR
DAMAGES, ARISING OUT OF THE USE OR INABILITY TO USE THIS PRODUCT OR
FOR ANY CLAIM BY ANY OTHER PARTY.
Should you have any questions concerning this Warranty, you may contact Helm by
writing or calling:
HELM INSTRUMENT COMPANY, INC.
CUSTOMER SERVICE
361 WEST DUSSEL DRIVE
MAUMEE, OHIO 43537
(419) 893-4356

i

PTM LOADGARD Series

Operators Manual

EXPLANATION OF SYMBOLS

~

Alternating Current
Earth (ground) TERMINAL

On (Supply)

Off (Supply)

Caution, risk of electric shock

Caution (refer to accompanying documents)

ii

EXPLANATION OF SYMBOLS ................................................................................................................................. ii
Introduction................................................................................................................................................................. 5
ABOUT PTM LOADGARD SERIES ........................................................................................................................... 5
Benefit ........................................................................................................................................................................ 5
PTM (Peak Tonnage Module) .................................................................................................................................... 5
Main Features ............................................................................................................................................................ 6
OPERATING MODES ................................................................................................................................... 6
LOOK WINDOW TIME (ms) - Only applicable to none Resolver Model ..................................................... 6
SAMPLING (also referred to as “Learning” or “Trending” cycles) ................................................................ 6
ALARMS ....................................................................................................................................................... 6
Other Features ........................................................................................................................................................... 7
TOUCH SCREEN INTERFACE ................................................................................................................................. 8
MAIN MENU ............................................................................................................................................................... 8
PRESS MONITOR ..................................................................................................................................................... 9
Tonnage Display Screen ............................................................................................................................................ 9
MAIN PEAK LOAD SCREEN ........................................................................................................................ 9
CURRENT JOB DISPLAY .......................................................................................................................... 12
ALARM INDICATOR & HISTORY .............................................................................................................. 12
ALARM HISTORY ....................................................................................................................................... 12
TOTAL PEAK DISAPLY FOR FRAME ....................................................................................................... 12
PEAK TONNAGE DISPLAY FOR FRAME (Ch1 – 4) ................................................................................. 12
TREND LED ................................................................................................................................................ 13
ALARM INDICATOR LED FOR FRAME CHANNEL .................................................................................. 13
PEAK DISPLAY FOR IN-DIE & ALARM INDICATOR (In-Die Screen Only) .............................................. 13
VIEWING CURRENT ALARM SETTINGS (In-Die Screen Only) ............................................................... 14
ALARM RESET ........................................................................................................................................... 14
ALARM SETUP ........................................................................................................................................... 14
OPERATING MODE ................................................................................................................................... 14
COPYING SAMPLE TO TARGET .............................................................................................................. 15
VIEW PEAK HISTORY ............................................................................................................................... 15
Peak History & SPC(Statistical Process Control) Charts ......................................................................................... 16
ZOOMED MODE ......................................................................................................................................... 16
CHANNEL SELECT BUTTONS .................................................................................................................. 16
CONFIG ...................................................................................................................................................... 16
CHANGE GRAPH RESOLUTION .............................................................................................................. 17
SCROLL ...................................................................................................................................................... 17
UNZOOM .................................................................................................................................................... 17
GRID ........................................................................................................................................................... 17
BOLD........................................................................................................................................................... 17
LEGEND ..................................................................................................................................................... 17
SPC ............................................................................................................................................................. 17
Current Alarm Setting ............................................................................................................................................... 18
Group Select ............................................................................................................................................... 19
HIGH CAPACITY ........................................................................................................................................ 19
LOW CAPACITY ......................................................................................................................................... 19
TARGET ...................................................................................................................................................... 19
+ TOL .......................................................................................................................................................... 19
- TOL ........................................................................................................................................................... 19
EXPAND FACTOR ...................................................................................................................................... 19
LEARNING CYCLE ..................................................................................................................................... 21
ADAPTIVE LEARNING ENABLE/DISABLE ............................................................................................... 21
DELTA TRACK EX...................................................................................................................................... 20

1

PTM LOADGARD Series

Operators Manual

ALARM WINDOW (ms) ............................................................................................................................... 21
(LOOK) WINDOW TIME (ms) - Only applicable to none Resolver Model .................................................. 21
ENABLING EDIT ......................................................................................................................................... 21
DOWNLOAD ............................................................................................................................................... 22
JOB RECIPE ............................................................................................................................................... 22
SAVING TO RECIPE DATABASE .............................................................................................................. 22
MAIN MENU ................................................................................................................................................ 22
Press Curve Alarm ................................................................................................................................................... 23
PTM Loadgard Press Curve Setup Procedure ........................................................................................................ 23
JOB ............................................................................................................................................................. 25
PEAK ........................................................................................................................................................... 25
HIGH CAP ................................................................................................................................................... 25
LOW CAP .................................................................................................................................................... 25
TARGET ...................................................................................................................................................... 25
SAMPLE ...................................................................................................................................................... 25
HIGH TOL ................................................................................................................................................... 25
LOW TOL .................................................................................................................................................... 25
WAVE VIEWING WINDOW ........................................................................................................................ 26
READ TONNAGE AT ANGLE .................................................................................................................... 26
ZOOM IN ..................................................................................................................................................... 27
RESET ZOOM ............................................................................................................................................ 27
TREND TYPE ............................................................................................................................................. 27
TREND ........................................................................................................................................................ 27
GRID ........................................................................................................................................................... 28
BOLD........................................................................................................................................................... 28
LEGEND ..................................................................................................................................................... 28
CHANNEL SELECT .................................................................................................................................... 28
OVERLAY ................................................................................................................................................... 28
Overlay Screens ....................................................................................................................................................... 28
SIGNATURE OVERLAY SCREEN ............................................................................................................. 29
SIGNATURE OVERLAY SCREEN ............................................................................................................. 29
PEAK BARS SCREEN ................................................................................................................................ 29
RECIPE MANAGER ................................................................................................................................................. 30
Recipe Main Screen ................................................................................................................................................. 30
JOB SUMMARY DISPLAY.......................................................................................................................... 30
NAVIGATION BAR ...................................................................................................................................... 30
EDIT ON ...................................................................................................................................................... 30
REMOVE ..................................................................................................................................................... 31
EDIT ............................................................................................................................................................ 31
ADD ............................................................................................................................................................. 31
COPY .......................................................................................................................................................... 31
DOWNLOAD ............................................................................................................................................... 31
MAIN MENU ................................................................................................................................................ 31
Job Setup Screen ..................................................................................................................................................... 32
JOB NAME .................................................................................................................................................. 32
HIGH CAPACITY ........................................................................................................................................ 32
LOW CAPACITY ......................................................................................................................................... 32
TARGET ...................................................................................................................................................... 32
+ TOL .......................................................................................................................................................... 33
- TOL ........................................................................................................................................................... 33
EXPAND FACTOR ...................................................................................................................................... 33
LEARNING CYCLE ..................................................................................................................................... 33
ADAPTIVE LEARNING ENABLE/DISABLE ............................................................................................... 33
ALARM WINDOW (ms) ............................................................................................................................... 34
(LOOK) WINDOW TIME (ms) - Only applicable to none Resolver Model .................................................. 34

2

PTM LOADGARD Series

Operators Manual

PASTE......................................................................................................................................................... 34
CANCEL ...................................................................................................................................................... 34
SAVE ........................................................................................................................................................... 34
PASSWORD CHANGE ............................................................................................................................................ 35
MASTER PASSWORD ............................................................................................................................... 35
ADMINISTRATOR PASSWORD ................................................................................................................ 35
OPERATOR PASSWORD .......................................................................................................................... 35
INITIAL PASSWORD .................................................................................................................................. 35
ADTSERVER SETUP SCREEN .............................................................................................................................. 36
Monitor Screen ......................................................................................................................................................... 36
OPERATING STATUS INDICATOR ........................................................................................................... 36
OPERATING MODE INDICATOR .............................................................................................................. 36
Sensor Calibration Screen ....................................................................................................................................... 37
System Setup Screen .............................................................................................................................................. 38
WINDOW TIME (ms) - Only applicable to none Resolver Model ............................................................... 38
PEAK WINDOW (Enable/Disable) - Only applicable to none Resolver Model ........................................... 38
SCALE SET ................................................................................................................................................ 38
TREND ALARM .......................................................................................................................................... 38
System Setup Screen for PTM-5600P/6700P ............................................................................................ 39
SCALE SET ................................................................................................................................................ 39
System Setup Screen for PTM-4500TSM/6700TSM/6700i-TSM ............................................................................ 40
TREND WARNING OUTPUT LEVEL ......................................................................................................... 40
SAVE ........................................................................................................................................................... 40
CANCEL ...................................................................................................................................................... 40
LOOK WINDOWS ....................................................................................................................................... 40
PTM LOADGARD ADC SETUP for TSM model .................................................................................................... 41





Go To ADC Manager .......................................................................................................................... 41
ADC Manager Setup ........................................................................................................................... 41
ADC RS232 CABLE CONNECTION .................................................................................................. 43

GETTING READY FOR CALIBRATION .................................................................................................................. 44
SYSTEM SPECIFICATIONS ................................................................................................................................... 46
BYPASS OPTION FOR PTM-4500TSM Model ....................................................................................................... 47
To enable the Bypass option, please contact Helm Instrument for further instruction. ADC ASCII PROTOCOL ... 47
ADC ASCII PROTOCOL .......................................................................................................................................... 48
APPENDIX A ( PTM-4500L2 ) - 4Ch Frame with 2 Linear Transducer ................................................................. 50
APPENDIX B ( PTM-2300L ) – 2Ch Frame/Indie with 1 Linear Transducer Input ................................................ 51
APPENDIX C ( PTM-6700i ) – 6Ch In-Die Applcation ........................................................................................... 52
APPENDIX D ( PTM-5600F ) – 3Ch In-die + 2Ch Frame application .................................................................... 53
APPENDIX E

( PTM-6700TSM ) 4Ch Frame + 2Ch Indea with Resolver Input ................................................... 54

APPENDIX F ( PTM-4400i ) 4Ch In-die application ............................................................................................... 55
APPENDIX G ( PTM-4500TSM )- 4Ch Frame with Resolver Input ...................................................................... 56
APPENDIX H ( PTM-4500TSM-ASA )- 4Ch Frame + Auto Shutheight Adjust w/ Resolver Input ........................ 57

3

PTM LOADGARD Series

Operators Manual

APPENDIX I ( PTM-5600P) - 5Ch Piezo Sensor Input .......................................................................................... 58
APPENDIX J ( PTM-4500) - 4Ch Frame with CAM input ...................................................................................... 59
APPENDIX K ( PTM-4500-ADC) - 4Ch Frame with Automatic Die Change Option .............................................. 60
APPENDIX L

LINE SUPERVISOR WITH RLG CONENCTION ........................................................................... 61

APPENDIX M ( PTM-6100-SS) - 4Ch Frame, 1Ch In-Die, 1Ch Laser Sensor ....................................................... 62
APPENDIX N ( PTM-6700i-TSM) - 6Ch In-Die With Trend Warning Output .......................................................... 63
APPENDIX O PTM LOADGARD DIMEMSION (Standard Mount) ......................................................................... 64
APPENDIX P PTM LOADGARD DIMEMSION (FLANGE MOUNT)....................................................................... 65
APPENDIX P-1 PTM LOADGARD PANEL PC CONNECTIONS LAYOUT ........................................................... 66
APPENDIX Q (PTM-884TSM-SS) 4Ch Frame, 4Ch In-Die Sensors...................................................................... 67
APPENDIX R (PTM-844TSM-SS) Connection Drawing ......................................................................................... 68
APPENDIX R (PTM-844TSM-SS) Connection Drawing ......................................................................................... 68
APPENDIX S (PTM-1248TSM-SS) 4Ch Frame, 8Ch In-Die Sensors .................................................................... 69
APPENDIX S (PTM-1248TSM-SS) 4Ch Frame, 8Ch In-Die Sensors .................................................................... 69
APPENDIX T (PTM-1248TSM-SS) Connection Drawing ....................................................................................... 70
APPENDIX U RLG Line Supervisor Connection .................................................................................................... 71
APPENDIX V PTM-102L Connections .................................................................................................................... 72
APPENDIX W PTM-4500TSM New I/O Board Connections .................................................................................. 73
APPENDIX X PTM-6600TSM for Doule Action Connections ................................................................................ 74
APPENDIX Y PTM-8800TSM for Doule Action Connections ................................................................................. 75

4

PTM LOADGARD Series

Operators Manual

INTRODUCTION
HELM INSTRUMENT CO., INC. manufactures a complete line of load monitoring control systems
for use on metal stamping, forging, compaction and assembly presses; cold forming, cold
heading, injection molding and die cast machines. Standard or custom transducers and load cells
are available for in-die monitoring and transfer or progressive tooling. At HELM, quality is
inherent not only in the design of our products but in the attitudes of our employees as well.
We're working together to give you the best. After all, that's what our business is all about providing innovative instrumentation to help make your manufacturing process more productive
and your operation more effective.

ABOUT PTM LOADGARD SERIES
PTM LOADGARD series is one of the most advanced load monitoring systems Helm can offer.
Sophisticated features such as smart sampling, adaptive learning, SPC(Statistical Process
Control) Charts, etc. help monitoring the operation of your machine and protect them from faulty
operation.

BENEFIT


Press Protection – protect press components, including dies, from costly damage



Parts Quality Control – ensure parts are being made (stamped) as specified

Variations in the mechanical press and the part making process have the costly potential of press
damage, waste of material, and downtime. The PTM LOADGARD uses force monitoring for both
press protection and parts quality control. If an excessive force that could potentially damage the
press machine or a variation in force occurs during the part making process are detected, the
PTM LOADGARD triggers an “alarm” and stops the press. This allows the press operator to
correct the potential problem ahead.

PTM (PEAK TONNAGE MODULE)


PTM is a single channel strain gage sensor input module to process the signal of the strain
gage to analog output.



PTM provides Auto-Zero® feature (patented by Helm Instrument Co., Inc.). The Auto-Zero®
feature automatically keeps the zero balance of the load signal between every load cycles to
compensate the tonnage variation affected by any environmental conditions changes such as
temperature.

5

PTM LOADGARD Series

Operators Manual

MAIN FEATURES
OPERATING MODES
PTM LOADGARD Series has three function modes controlled by an operator.


Setup Mode – Used for system setup, Job setup or new job download.
Capacity alarms are active. Trend Alarms are active if the Trend Alarm in
Setup option is enabled from Server Setup screen. Target value is used
for monitoring the Trend alarm conditions as a reference point.



Learn Mode – Learns new sample value.
Capacity alarms are active. Trend alarms are active if the Trend Alarm in
Setup option is enabled from Server Setup screen. Target value is used
for monitoring the Trend alarm conditions as a reference point.



Monitor Mode – Adaptive learning can be active in this mode.
Capacity alarms are active. Trend alarms are active. Sample value is
used for monitoring the Trend alarm conditions as a reference point.

LOOK WINDOW TIME (ms) - Only applicable to none Resolver Model
PTM LOADGARD monitors tonnages between the “critical” time of the press stroke called the
look window. 224 points (tonnage readings) per channel are recorded during the look window
time from the look window start trigger point. These points are displayed as a “wave” or
“signature” in the Signature Analysis screen.

SAMPLING (also referred to as “Learning” or “Trending” cycles)
Samples for pre-determined number of press strokes, defined as sample counts in Alarm Setup
screen.
When the sampling is completed, PTM LOADGARD takes an average peak tonnage and / or
tonnage signature per channel (while sampling), and stores as a Sample peak value and/or
Sample Signature per channel and uses it as a reference point for Trend / Tracking Alarm
conditions.


Sample – Sample is the value learned automatically from Learn mode or Monitor mode
by adaptive learn feature. The Sample value is used to calculate the Trend and Tracking
Alarm condition in Monitor mode.



Target – When you create a new job, Target values need to be entered manually. These
values can be copied from the Sample values when Leaning process is completed for the
job. The Target is used during Setup or Learn mode to monitor the Trend Alarm
conditions before new Sample values are available.

ALARMS
In normal operation, the Alarm relay is closed for fail safe. When the tonnage alarm(s)
condition is detected, the system opens the TOP STOP relay


High/Low Capacity – Normally set at machine capacity. This provides the protection for
the Machine. This alarm is active in all modes.



High/Low Trend – creates high and low tolerance for peak load based on Target or
Sample tonnage. The tolerance values are the allowable tonnage deviation above and
below Sample or Target tonnage. This provides the means to maintain the quality of the
part making. Trend alarms are available in all modes. There is an option to disable the
Trend alarm during Setup or Learn mode.

6

PTM LOADGARD Series

Operators Manual



High/Low Tacking – creates high and low tolerance bands around the sample tonnage
signature for monitoring the alarm condition through out the stroke. Tracking alarm is only
available in Monitor mode



Press Curve (only available for Resolver based model) – Since a press may have
different force capacities at different angles, the press manufacture may provide a
“through the stroke press-curve and motion curve” set of data points. This alarm is valid
in both setup and Monitor mode.

OTHER FEATURES


Signature Analysis – Displays the forming force signature for each channel. You can
zoom, read the tonnage value at angle, overlay multiple channels, view multiple peak
tonnage value in bar graph, and more to help you analyzing the force signature.



Alarm History – You can view last 500 alarm messages with time stamped.



Peaks History – You can view a peak tonnage history graph of last 10000 strokes.



SPC (Statistical Process Control) – You can view statistical charts of peak tonnage
variation from selected peak history. Avail SPC charts are Individual & Moving Range,
*Average & Range, *Median & Range, *Average & Std. Deviation, and Histogram



Jobs Recipe – You create alarm settings per job base and store to Job Recipe for later
quick download to setup the system.



Adaptive learning – While the system is in Monitor mode, you can enable an Adaptive
Learning option to continuously learn new sample tonnage while monitoring. This will
allow the system to adapt any small gradual variances of the tonnage through time when
requires



Multi-Level Password Protection – you can restrict certain functions or screens of the
system from being accessed by unauthorized personnel or prevent from unauthorized
changes of the system settings. Different level of passwords gives more secure and
effective protection for the system.

7

PTM LOADGARD Series

Operators Manual

TOUCH SCREEN INTERFACE
MAIN MENU
Main menu allows you to access different area of the system. The PTM LOADGARD™
features a touch screen display for easy navigation and operation of the system. Click or
touch on the button you wish to access.

PRESS MONITOR – This is where you can monitor the peak tonnage values, tonnage
signatures, change Alarms setting, view Alarm Messages, SPC and more.
RECIPE MANAGER – You can create a new job, edit or delete existing jobs, and download a
job settings to the system.
PASSWORD EDIT – set or change the passwords.
ADTSERVER – helps to diagnose the system status for the trouble shooting purposes. Initial
and system setup is done here.
SHUTDOWN – prepares the system to be powered down safely. This is protected by
operator password. Use “4356123” as password to exit out to Windows Desktop screen
without shutting down the system.
Warning: We recommend to use SHUTDOWN button before powering down the system.
Improper shutting down of the system may cause an abnormal system operation.

8

PTM LOADGARD Series

Operators Manual

PRESS MONITOR
TONNAGE DISPLAY SCREEN
PRESS MONITOR provides the screens to view peak tonnage load, Tonnage signatures, ,peak
tonnage history, and SPC charts, You can change Alarm settings and view Alarm Messages as
well.

MAIN PEAK LOAD SCREEN FOR VARIATY PTM MODELS
This screen displays peak tonnage values, alarm settings, and alarm indicators for all channels.
Alarm Indicator & Alarm History
Alarm Setting
Display

Trend LED

Alarm Indicator LED

Total Peak Display

Main Tonnage screen from PTM-4500L2

Main Tonnage screen from PTM-6700TSM

9

Peak Tonnage Display

PTM LOADGARD Series

Operators Manual

Main Tonnage screen from PTM-4500TSM

Main Tonnage screen from PTM-2300PG

Main Tonnage screen from PTM-5600P

10

PTM LOADGARD Series

Operators Manual

FOR DOUBLE ACTION PRESS MACHINES

Main Tonnage screen from PTM-6600TSM-DA

Main Tonnage screen from PTM-8800TSM-DA

11

PTM LOADGARD Series

Operators Manual

CURRENT JOB DISPLAY
Shows current Job name. Job name can be edited from
RECIPE MANAGER screen

ALARM INDICATOR & HISTORY
This ALARM INDICATOR button has two functions, It indicates
any alarms tonnage condition and lets you view alarm history.
When the machine is running within normal parameter, the
message on the button shows ALARM HISTORY. The message
ALARM with red color background indicates there is an alarm
condition(s). In this case, it will flash the message “Click Here
for Detail”. To view the detail message of the alarm, click on the
display to open ALARM HISTORY screen. You can click on this
display to view previous alarm messages at anytime.

ALARM HISTORY
Click on ALARM WARNING DISPLAY button to view ALARM HISTORY.
You can view up to last 500 alarm
messages that have date and
time stamp. Use the scroll bar on
the right side of the list box or
arrow buttons on the bottom to
scroll up and down the history list.
Use Clear button to empty all
messages.
Note: you need administrator or
higher level of password to clear
the alarm history.

TOTAL PEAK DISAPLY FOR FRAME
TOTAL displays the summation of the four corner peak tonnages .
This value is the actual peak tonnage load that the press is taking in
each cycle.

PEAK TONNAGE DISPLAY FOR FRAME (Ch1 – 4)
This peak display shows the peak tonnage load of each channel within the look window from
each cycle of the press.

12

PTM LOADGARD Series

Operators Manual

TREND LED
The vertical bar meter next to the peak display box is a Trend Display bar. It
shows the visual reference of a peak tonnage variation comparing to TARGET or
SAMPLE tonnage for Trend Alarm. The center green light indicates 0% variance
within the tolerance of the Trend Alarm. The green light, one above the center,
indicates 25% variance. Toward to the red light on the top, the yellow light shows
50% and 75%. Once the tonnage reaches 100% of the tolerance or beyond, all
the bars from the center to top light up and it indicates the High Trend Alarm
condition. This applies to Low Trend Alarm as well. Only difference is the
negative percentage (-25%, -50%, -75% and –100%) and opposite instead.

ALARM INDICATOR LED FOR FRAME CHANNEL
When alarm(s) occurred, ALARM INDICATOR LED displays the cause of the
alarm.
H CAP (HIGH CAPACITY ALARM)
When the peak tonnage of an individual channel reaches the high limit of the
setting for Capacity alarm, the black rectangle next to the description will turn
red to indicate that High Capacity alarm is triggered. Refer to ALARM SETUP
SCREEN for details.

H TND (HIGH TREND ALARM)
When the peak tonnage of an individual channel reaches the high limit of the setting for Trend
Alarm, the black rectangle next to the description will turn red to indicate that a High Trend alarm
is triggered. Refer to ALARM SETUP SCREEN for details.
L TND (LOW TREND ALARM)
When the peak tonnage of an individual channel reaches the low limit of the setting for Trend
Alarm, the black rectangle next to the description will turn red to indicate that a Low Trend alarm
is triggered. Refer to ALARM SETUP SCREEN for details.
L CAP (LOW CAPACITY ALARM)
When the peak tonnage of an individual channel reaches the low limit of the setting for Capacity
alarm, the black rectangle next to the description will turn red to indicate that a Low Capacity
alarm is triggered. Refer to ALARM SETUP SCREEN for details.

PEAK DISPLAY FOR IN-DIE & ALARM INDICATOR (In-Die Screen Only)
Gag Tool Input Indicator
Peak Display
Trend LED

Low Capacity
Alarm Indicator

High Capacity
Alarm Indicator

High Trend Alarm
Indicator

Low Trend Alarm
Indicator

13

PTM LOADGARD Series

Operators Manual

VIEWING CURRENT ALARM SETTINGS (In-Die Screen Only)

Click on one of the buttons to view current alarm setting values. The values will
be displayed in the Peak tonnage display boxes for 20 seconds and change back
to PEAK automatically.
The TOTAL PEAK display box shows the viewing mode currently selected.
PEAK
TARGET
SAMPLE
HIGH CAP
+TOL

(TARG)
(SAMP)
(HCAP)
(+TOL)

-TOL

(-TOL)

LOW CAP (LOW)
EFACTOR (EFAC)

Current peak tonnage value.
Target tonnage value.
Sample tonnage value.
High Capacity tonnage limit
High tolerance tonnage limit above the Sample or Target
value.
Low tolerance tonnage limit below Sample or Target
value
Low capacity tonnage limit
Expanded Factor which is tolerance multiplier to
increase the tolerance band in Setup & Learn Mode

ALARM RESET
Once the Alarm output relay is disengaged by an alarm condition(s), click on
the RESET button to clear all alarm indication and alarm relay output.

ALARM SETUP
Click on ALARM SETUP button to bring up CURRENT ALARM SETTING screen
where you can set or change the current alarm settings and download the new
settings to the system to take effect. You can also stores any change you made
in this screen to Recipe database easily. Refer to CURRENT ALARM SETTING
for details.

OPERATING MODE
Operating mode can be switched by clicking one of the
CURRENT MODE buttons. While in LEARN mode, the
mode always changes to MONITOR mode
automatically after LEARN cycle is completed.
Setup Mode – Used for system setup, Job setup or job download.
Capacity alarms and Trend alarms are available. The tolerance band for Trend alarm is
calculated by Target value + ( ±TOL x Expand Factor ). You can enable or disable the Trend
Alarm from System Setup screen.

14

PTM LOADGARD Series

Operators Manual

Learn Mode – In LEARN mode, system averages the peak values for each channel during the
predefined learning cycle. Once the learning cycle is completed, the each average value is stored
as sample value for each channel and the operating mode automatically switches to Monitor
mode. Capacity alarms and Trend alarms are available during Learn mode. The tolerance band
for Trend alarms is calculated by Target value + ( ±TOL x Expand Factor ). You can enable or
disable the Trend Alarm from System Setup screen.
Note: you can define the number of Learn Cycle and store it as a part of job recipe item in Job
Setup screen.
Monitor Mode – In Monitor mode, you have the option to enable or disable the Adaptive
Learning feature which is part of job recipe item. When the Adaptive Learning is active, the
system continuously re-learns sample values while monitoring for any alarm condition. You can
change the number of Adaptive Learning cycle by changing the Learning Cycle from Alarm
Setup screen.
ADPT ON/OFF - This indicates whether Adaptive Learning feature is turned on or off.
Once the Adaptive Learn is active, you should see that the green LED on the mode select button
flashes.

COPYING SAMPLE TO TARGET
Use COPY button to replace the TARGET value with the SAMPLE value. It is
useful when you have to arbitrary set the Target value for a new job for the first
time. After the Learning procedure is completed for a new job, click on the COPY
button to update the Target values with the Sample values. When making a copy,
it prompts with a message to give you the option to update the new TARGET
values to the Recipe database for a current job.

VIEW PEAK HISTORY

Click this button to open PEAK TONNAGE HISTORY screen where you can view
a recorded peak tonnage graph up to previous 1000 hits in one screen. Also, you
can select the range of the peak history to display SPC (Statistical Processor
Control) charts. Refer PEAK HISTORY & SPC for details.

15

PTM LOADGARD Series

Operators Manual

PEAK HISTORY & SPC(STATISTICAL PROCESS CONTROL) CHARTS

Zoom Mode
Indicator

Channel Select
Buttons

ZOOMED MODE
This indicates that the current history graph has been zoomed. To zoom the graph, point to the
area on the screen where you want to start zooming and drag the point down right to create a
zoom rectangle. Once the inside of the zoom rectangle covers the area where you want to zoom
in, release the point from the screen. You can repeat this to continue zooming within the area.

CHANNEL SELECT BUTTONS
Toggle the buttons to add or remove the peak graph of the channel from the history graph.

CONFIG

You can define how often the peak values need to be recorded into the
peak history. Set the Update Frequency value and click Save to take
effect the new setting.

16

PTM LOADGARD Series

Operators Manual

CHANGE GRAPH RESOLUTION
The Peak history records up to 10,000 previous peak values. You can
change the number of viewable peak points on a graph by choosing
one of the options
100pt – to display 100 peak points at a time
500pt – to display 500 peak points at a time
1000pt – to display 1000 peak points at a time

SCROLL
These buttons let you scroll left or right to view rest of the peak points outside
the graph. Click left arrow button to scroll left, right arrow button to scroll right.

UNZOOM
Click this button to reset the zoomed graph and return to original size.

GRID
Click this button to show or hide vertical and horizontal grid lines on Peak Graph
screen.

BOLD
Click this toggle button to make the width of the peak graph line bold.

LEGEND
Click this button to show or hide the legend of the graphs displayed on the screen.

SPC
Click this button to generate SPC charts within the peak data displayed on the history
graph. Use Zoom or Scroll to select the range of the peak history to generate SPC
chart you want to see.
If more than one channel is displayed in the history graph, SPC averages them to
generate the charts.

17

PTM LOADGARD Series

Operators Manual

CURRENT ALARM SETTING

Resolver TSM model: PTM 2300/4500/6600DA/6700TSM

None Resolver model: PTM-4500

In CURRENT ALARM SETTING, you can view / edit the current alarm settings and also save the
change to current job database and download the change to ADTServer.

18

PTM LOADGARD Series

Operators Manual

Group Select
Select Group Select option if you want all channels to have same settings.

HIGH CAPACITY
HIGH CAPACITY is the limit for the maximum peak tonnage allowed to operate the machine.
Normally the value is set at or below the scale value which is the capacity of the machine
divided by the number of frame sensor channels. HIGH CAPACITY alarm is available in all
modes.
Note: You need to enable the Edit mode by using Administrator or higher level of password in
order to make any changes from this screen.

LOW CAPACITY
LOW CAPACITY is the limit of the minimum peak tonnage allowed to operate the machine.
Normally the value is set for 0 (disabled) unless there is a special need. LOW CAPACITY
alarm is available in all modes.

TARGET
The concept of TARGET is to provide a Trend alarm protection for SETUP and LEARN
modes. Normally, Trend Alarm requires a sample tonnage to compare the current peak
tonnage to monitor the alarm condition. However, the Sample value is only available when
the system has completed its Learning cycle and the operating mode has been changed to
Monitor mode. In typical load monitoring system, the Trend alarm is not available during
Setup and Learn mode. In this system, the TARGET feature is to gives you the full protection
of Trend Alarm by letting you manually enter the expected tonnage value for the job before
running the press. Once the machine has started and acquired new Sample values by
Learning procedure, you can update the Target values with them by clicking the Target
COPY button in the main Tonnage screen. In case that you try to run a new job and are not
sure where the Targets need to be set at, you can set each Target value to zero. This will
disable the Trend Alarm on a channel by channel basis. After system learns the new sample
values, you can use the Target Copy command to update the Target values.
Note: While the system is in Setup or Learn mode, adjust Expand Factor to increase the
tolerance band to avoid unnecessary Trend alarm warning. Refer to Expand Factor for
details.

+ TOL
This is the upper tolerance tonnage limit for a High Trend alarm of each channel. This limit
prevents the current peak tonnage load from exceeding the +TOL tonnage setting above the
Target (In Setup or Learn mode) or Sample (In Monitor mode) value.
Note: Depending on EXPAND FACTOR value, actual tolerance may differ from the value that
was set while the system is in Setup or Learn mode. Refer to EXPAND FACTOR for detail.

- TOL
This is the lower tolerance tonnage limit for a Low Trend alarm of each channel. This limit
prevents the current peak tonnage from exceeding the -TOL tonnage setting below the
Target (In Setup or Learn mode) or Sample (In Monitor mode) value.
Note: Depending on EXPAND FACTOR value, actual tolerance may differ from the value that
was set while the system is in Setup or Learn mode. Refer to EXPAND FACTOR for detail.

EXPAND FACTOR
These are the multipliers for the + and -TOL values to increase the range of the tolerance
bands so that the system has less chance to fire Trend alarms while the press is running in
SETUP or LEARN mode. Once the system is in Monitor mode, This EXPAND FACTOR does
not affect the tolerance for Trend and Tracking alarm band in PLM model. However, in TSM

19

PTM LOADGARD Series

Operators Manual

model(with Resolver), this expand factor still applies to the Tolerance setting for Trend alarm,
but not Tracking alarm.
Example:

Target = 60 , Sample = 64, +Tol = 10, -Tol =15, Exp Factor = 2.0
In Setup or Learn mode
Actual High Trend limit = 60 + (10 * 2.0) = 80
Actual Low Trend limit = 60 - (15 * 2.0) = 30
In Monitor mode
Actual High Trend limit = 60 + 10 = 70
Actual Low Trend limit = 60 - 15 = 45

DELTA TRACK EX
Delta Track feature pertains to the filtering of tracking alarms, and help avoid “nuisance” type
alarms. The filtering occurs during sudden force change through the press stroke. Delta
Track filtering can be seen in the signature screen, where high slopes area of the sample
signature (along with the tracking bands) are filtered out during relatively small portion of the
stroke.
Filter level can be adjusted. Enter a value between 1 and 99 to determine how much of the
slope rate area to be filtered. 99 filter the least and 1 will filter the most out of the slope area.
Enter ‘0’ to disable Delta Track filtering.
Enter “100” to enable Perpendicular Tolerance(PT) tracking bands.
PT Tracking generates the tracking bands that envelop around the sample signatures evenly
throughout the alarm window area. This Tacking gives you the ability to monitor tracking
alarm in very tight tolerance setting without cause “nuisance” alarm by any minimal horizontal
shiftiness of the force signature.

Standard Tracking at 15% Tolerance

Delta Track Enabled & set at 80

P.T. Tracking at 3% Tolerance

20

PTM LOADGARD Series

Operators Manual

LEARNING CYCLE
Enter the number of cycles to take to learn new Sample values in LEARN mode. In
MONITOR mode, Adaptive Learning feature uses this cycle to learn new Samples when it is
enabled. In TSM Model, enter 0 to use Target values as Sample for Trend alarm in Monitor
mode without going through learning process for new sample. Note that Learn Cycle set to
“0” disables Tracking alarm.

ADAPTIVE LEARNING ENABLE/DISABLE
You can enable or disable Adaptive Learning feature in MONITOR mode. By enabling the
Adaptive Learning, the system continuously learns new sample values while it is in Monitor
mode and applies the new Sample values to monitor Trend alarm conditions as soon as
available. This will allow the system to adapt any small gradual variances of the tonnage
load through the time which are caused by environmental change such as temperature. If
any tonnage load that causes an alarm, the reading is excluded from Adaptive Learning
process.

ALARM WINDOW (ms)
Set alarm window to adjust the area of the force signature to monitor for tracking alarm. If
PEAK WINDOW is enabled, this ALARM WINDOW determined the area of the signature to
capture the peak tonnage instead of from entire signature. Enter start and stop Alarm
Window times in msec within Window Time.
Note: In Resolver model, enter the range of the angle value instead of time.

(LOOK) WINDOW TIME (ms) - Only applicable to none Resolver Model
Look Window Time is the duration of time when the force signature and peak tonnage is
captured. The WINDOW TIME need to be adjusted based on the speed of the machine to
capture optimal force signature.

ENABLING EDIT
Before you are able to make any changes on the settings in this screen, you
have to enable Edit mode first. To do so, click on Edit button and enter a
password to enable the Edit mode. Depending on the password clearance
level, restrictions will apply.

Default Password:
Operator password = “123”
Administrator Password = “123456”
Master Password = “1968”

21

PTM LOADGARD Series

Operators Manual

Here is the table for editable contents based on the password type.
Functions
Operator
Administrator
Password
Password
Scale Value change
High/Low Capacity Setting
Window Time Setting
Tracking Threshold Set
High/Low Tolerance Setting
Target/ EXP Factor
Tracking On/Off
Learn Cycle Count
Alarm Window Setting
RECIPE Job Download
RECIPE Job Add/Edit/Delete

X
X
X
X
O
O
O
O
O
O
X

Master
Password

X
X
O
X
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O
O
O

DOWNLOAD
Click this button to download new alarm settings to system. Downloading
is only allowed in Setup mode. If the system is currently in LEARN or
AUTOMATIC mode, it will prompt with a message that will ask if you want
to switch back to SETUP mode.
Note: Any change of settings you make in this screen will take effect after
Download is completed.

JOB RECIPE
Click this button to go to RECIPE MANAGER screen.

SAVING TO RECIPE DATABASE
Click this button to update current job stored in Recipe database with the
new settings made from this screen.

MAIN MENU
Click this button to return to main tonnage screen

22

PTM LOADGARD Series

Operators Manual

PRESS CURVE ALARM
The resolver based PTM Loadgard system allows the operator to enter the specified 36
press curve points in the Press Curve Data Setup screen for Press Curve Alarm.
Multiple press curve data can be saved. Select a press curve data file and click download to
active it.
PTM LOADGARD PRESS CURVE SETUP PROCEDURE
Press Curve data
files stored in
memory
Data from the
selected file
stored in
memory.

Active Press Curve
data in the Loadgard
System.

When new data has
been downloaded,
click Refresh to
update the screen
with new data

To edit the data
in the selected
file. This will
lead to PRESS
CURVE DATA
entry screen

Turn Edit On to make
changes

Download a selected
Press Curve data file
to be active data

Copy all data points from a
selected file and paste the
same data into a different file
selected

A. How to edit existing Press Curve data file
1. Select the file you created from the list then click
Edit button to enter date points
2. Edit the value in 36 points to match Press Curve
data. starting 0 degree in degree, enter data every
10 degree. The data is a percent value x 10 of total
capacity of the machine.
3. For example, if the press capacity is 500t and the
press is rated as 250t at 90 degree crank angle
according to the press curve chart, then enter 500
th
(50% x 10 = 500) for 9 data entry point. The
formula is:

PRESS CURVE DATA ENTRY
SCREEN

Press Curve Data Value = (Capacity @ angle / Press Capacity) * 1000
( 250 / 500 ) x 1000 = 500

23

To create a new
press curve data file.

PTM LOADGARD Series
B.

Operators Manual

How to Create a new Press Curve data file.
1. First you need 36 data points from Angle vs. Tonnage capacity graph.
2. Turn Edit On.
3. Click Create button and name your data file using the pop-up keyboard.
4. Select the file you created from the list then click Edit button to enter date points
th
5. Enter 36 points for Press Curve date. starting 10 degree, enter data every 10 degree.
The data is a percent value x 10 of total capacity of the machine.
Please refer to the table below for example how to calculate the data points for each degree.
Press Capacity: 500t
Crank Angle
Capacity@Angle Press Curve Data
(Degree)
(t)
(% x 10)
10
100
200
20
110
220
30
120
240
40
140
280
50
180
360
60
200
400
70
225
450

C.

Press Curve Data Value = (Capacity @ angle / Press Capacity) * 1000
For example, if the press capacity is 500t and the press is rated as 250t at 90 degree crank angle
th
according to the press curve chart, then enter 500 (50% x 10 = 500) for 9 data entry point.
( 250 / 500 ) x 1000 = 500
How to Download A Press Curve Data File to be Active .
1. Select a Press Curve data file
created in PRESS CURVE DATA
FILES list and click DOWNLOAD
button.
2. Click Refresh button to update the
CURRENT DATA list screen with
the recently downloaded data.
3. Click Return to go back to Alarm
Setup screen and enable Press
Curve feature for each Channel.

24

PTM LOADGARD Series

Operators Manual

Signature (Wave) Display Screen

The Signature Display screen displays real-time force signatures for individual channels. The
overlaying with other signatures or graphs help you to monitor the operating status of the
machine or verify the alarm conditions easier.

JOB
This is the current job name downloaded from RECIPE MANAGER.

PEAK
Current peak tonnage value for the channel currently displayed.

HIGH CAP
High Capacity Alarm setting value in tons for the channel currently displayed.

LOW CAP
Low Capacity Alarm setting value in tons for the channel currently displayed.

TARGET
TARGET setting value in tons for the channel currently displayed.

SAMPLE
SAMPLE value in tons for the channel currently displayed.

HIGH TOL
+ TOLERANCE setting value in tons for the channel currently displayed.

LOW TOL
- TOLERANCE setting value in tons for the channel currently displayed.

25

PTM LOADGARD Series

Operators Manual

WAVE VIEWING WINDOW
HIGH CAPACITY

CURRENT
CHANNEL
NUMBER

LEGEND

ZOOM
INDICATOR

HIGH TREND

SAMPLE/
TARGET

LOW TREND
CURRENT WAVE
READ TONNAGE
@ ANGLE

LOW CAPACITY

ZOOM INDICATOR:
HIGH CAPACITY:
HIGH TREND:
LOW TREND:
SAMPLE/TARGET:
LOW CAPACITY:
CURRENT WAVE:

This message indicates that the graph is currently zoomed.
High Capacity limit
Upper limit of trend alarm band
Lower limit of trend alarm band
In SETUP and LEARN mode, it displays the Target line.
In AUTOMATIC mode, it displays the Sample line.
Low Capacity limit
Current tonnage signature read from sensor.

READ TONNAGE AT ANGLE
Click on this button to enable the Read
Tonnage at Angle feature. To view the
tonnage at angle, click on the
coordination you want to read from the
signature screen. You can view up to
20
readings
on
a
screen
simultaneously. Use Back or Clear
button at the top-right corner to delete
unwanted readings.
To delete last reading on the
screen

To clear all readings on the
screen

26

PTM LOADGARD Series

Operators Manual

ZOOM IN
The Zoom feature allows the user to “zoom in” on a selected area of the signature
for analysis at a higher resolution. Click this button to put the signature screen in
zoom mode.
Note: Once the wave is zoomed, a message “ZOOMED” shows up on the top-left
corner of the Signature View Window to indicate that signature is currently in
zoomed mode.
To select an area to zoom in: Press
touch screen (and keep pressed) at
top left area of desired part of wave
to zoom in, and drag finger at a
diagonal down and to the right. A box
will be drawn and finger followed as
the touch screen is pressed. Release
touch screen to draw zoomed-in part
of the wave.
Repeat Zooming is permitted to
continuously zoom in on a particular
area of a signature.

RESET ZOOM
Click this button to return full view(unzoom)

TREND TYPE
Click this button to open the SELECT TREND GRAPH TO SHOW screen where you
can
select which Trend graphs to be displayed when TREND button is activeted.
You can add/remove different types of
trend graphs you desire to overlay on the
signature screen. To add, click on the
button you want to view. When the button
is pushed in, the option for the graph is
added. Click again to remove it.
Note: This option only works with TREND
button.

TREND
Toggle this button to show or hide the trend graphs selected from TREND TYPE
option. This will give the visual references of the alarm settings and forming force
related to the Sample.

27

PTM LOADGARD Series

Operators Manual

GRID
Click this button to show or hide vertical and horizontal grid lines on the wave
screen.

BOLD
Click this toggle button to make the current signature graph line bold.

LEGEND
Click this button to show or hide the legend of the graphs displayed on the screen.

CHANNEL SELECT
Thru

Select a button to display the corresponding channel signature on
the screen.

OVERLAY
Click this button to view the overlay of multiple channels of current signatures. Also,
you can select the option to view multi-channel peak bar graph from here. Refer to
OVERLAY SCREEN for details
Note: You cannot view Trend graphs while Overlay screen is on. All other features are
still available.

OVERLAY SCREENS
You can add/remove multiple channels
of signatures to overlay on one screen
by clicking the channel buttons from
Select Channels To Overlay screen.
Choose the channel(s) you wish to
view and click Show button to view
Signature Overlay.
Select SHOW AS BAR to view Peak
Bars instead.

28

PTM LOADGARD Series

Operators Manual

SIGNATURE OVERLAY SCREEN

PEAK BARS SCREEN
Trend alarm
Tolerance range
bar

Color coded Alarm
Indication

High Capacity limit

Peak Tonnage
reading

Peak Tonnage Bar

29

PTM LOADGARD Series

Operators Manual

RECIPE MANAGER
RECIPE MAIN SCREEN
Recipe Manager is where you can create and store new jobs, edit or delete existing jobs, and
download the job you want to set the system for. You can store virtually unlimited number of
jobs.
NAVIGATION
BAR
CURRENT
ACTIVE JOB

JOB SUMMARY
DISPLAY

JOB SUMMARY DISPLAY
Job Summary Display shows a list of all stored jobs that have been created and saved into a
job database. Each job is listed with job name and note. By clicking on one of the jobs from
the list, it will highlight the job and make it as an active job. The active job can only be
Edited, Removed or Downloaded. You can use navigation bar on the right side of the list box
to change the active job.

NAVIGATION BAR
You can select an active job by using navigation buttons. It will help you to navigate through
the Job Summary Display to select the job you want by using touch of buttons instead of
dragging small scroll bar.

EDIT ON
In order to Add, Edit, Delete, or Download an active job, The Edit button on the bottom-left of
the screen must be turned on. This enables Edit, Add, Remove, and/or Download buttons
depending on which level of password is entered. Download requires either the Operator
level or higher password. Edit, Add and Remove require Administrator level or higher
password.

30

PTM LOADGARD Series

Operators Manual

REMOVE
REMOVE button deletes a current active job from the Job Summary Display.
Select the job you wish to delete and click on REMOVE button.

EDIT
EDIT button will lead you to JOB SETUP screen where you can make changes
of current active job settings such as Job name, alarm settings, etc. In order to
edit a job, select the job you wish to edit from Job Summary Display and click
on EDIT button.

ADD
Click Add button to bring up JOB SETUP screen. All parameters for alarm
settings will be blank except the High Capacity alarm. The High Capacity alarm
is predefined by previous job.

COPY
When you create a new job, you can also copy the settings from an existing job
from the Job Summary List and paste them into a new job or the existing job.
To copy a job, select the job you want to copy and click on COPY button. Once
you go to JOB SETUP screen to add or edit a job, you will see that PASTE
button is enabled. Click on the PASTE button to paste the settings, you copied,
into the alarm settings for the job.

DOWNLOAD
Click DOWNLOAD button to download the current active job to ADTServer to
take effect of the new settings. The operation mode has to be in SETUP mode to
download the job.

MAIN MENU
Click this button to return to Main menu.

.

31

PTM LOADGARD Series

Operators Manual

JOB SETUP SCREEN
This is where you can edit or enter new settings for the job you created.

JOB NAME
Enter a job name for the job you created. This will identify each job in the Job database. You
can enter any character up to 20 characters.

HIGH CAPACITY
HIGH CAPACITY is the limit for the maximum peak tonnage allowed to operate the machine.
Normally the value is set at or below the scale value which is the capacity of the machine
divided by the number of frame sensor channels. HIGH CAPACITY alarm is available in all
modes.
Note: You need to enable the Edit mode by using Administrator or higher level of password in
order to make any changes from this screen.

LOW CAPACITY
LOW CAPACITY is the limit of the minimum peak tonnage allowed to operate the machine.
Normally the value is set for 0 (disabled) unless there is a special need. LOW CAPACITY
alarm is available in all modes.

TARGET
The concept of TARGET is to provide a Trend alarm protection for SETUP and LEARN
modes. Normally, Trend Alarm requires a sample tonnage to compare the current peak
tonnage to monitor the alarm condition. However, the Sample value is only available when
the system has completed its Learning cycle and the operating mode has been changed to
Monitor mode. In typical load monitoring system, the Trend alarm is not available during
Setup and Learn mode. In this system, the TARGET feature is to gives you the full protection
of Trend Alarm by letting you manually enter the expected tonnage value for the job before
running the press. Once the machine has started and acquired new Sample values by
Learning procedure, you can update the Target values with them by clicking the Target
COPY button in the main Tonnage screen. In case that you try to run a new job and are not
sure where the Targets need to be set at, you can set each Target value to zero. This will

32

PTM LOADGARD Series

Operators Manual

disable the Trend Alarm on a channel by channel basis. After system learns the new sample
values, you can use the Target Copy command to update the Target values.
Note: While the system is in Setup or Learn mode, adjust Expand Factor to increase the
tolerance band to avoid unnecessary Trend alarm warning. Refer to Expand Factor for
details.

+ TOL
This is the upper tolerance tonnage limit for a High Trend alarm of each channel. This limit
prevents the current peak tonnage load from exceeding the +TOL tonnage setting above the
Target (In Setup or Learn mode) or Sample (In Monitor mode) value.
Note: Depending on EXPAND FACTOR value, actual tolerance may differ from the value that
was set while the system is in Setup or Learn mode. Refer to EXPAND FACTOR for detail.

- TOL
This is the lower tolerance tonnage limit for a Low Trend alarm of each channel. This limit
prevents the current peak tonnage from exceeding the -TOL tonnage setting below the
Target (In Setup or Learn mode) or Sample (In Monitor mode) value.
Note: Depending on EXPAND FACTOR value, actual tolerance may differ from the value that
was set while the system is in Setup or Learn mode. Refer to EXPAND FACTOR for detail.

EXPAND FACTOR
These are the multipliers for the + and -TOL values to increase the range of the tolerance
bands so that the system has less chance to fire Trend alarms while the press is running in
SETUP or LEARN mode. Once the system is in Monitor mode, This EXPAND FACTOR does
not affect the tolerance.
Example: Target = 60 , Sample = 64, +Tol = 10, -Tol =15, Exp Factor = 2.0
In Setup or Learn mode
Actual High Trend limit = 60 + (10 * 2.0) = 80
Actual Low Trend limit = 60 - (15 * 2.0) = 30
In Monitor mode
Actual High Trend limit = 60 + 10 = 70
Actual Low Trend limit = 60 - 15 = 45

LEARNING CYCLE
Enter the number of cycles to take to learn new Sample values in LEARN mode. In
MONITOR mode, Adaptive Learning feature uses this cycle to learn new Samples when it is
enabled.

ADAPTIVE LEARNING ENABLE/DISABLE
You can enable or disable Adaptive Learning feature in MONITOR mode. By enabling the
Adaptive Learning, the system continuously learns new sample values while it is in Monitor
mode and applies the new Sample values to monitor Trend alarm conditions as soon as
available. This will allow the system to adapt any small gradual variances of the tonnage
load through the time which are caused by environmental change such as temperature. If
any tonnage load that causes an alarm, the reading is excluded from Adaptive Learning
process.

33

PTM LOADGARD Series

Operators Manual

ALARM WINDOW (ms)
Set alarm window to adjust the area of the force signature to monitor for tracking alarm. If
PEAK WINDOW is enabled, this ALARM WINDOW determined the area of the signature to
capture the peak tonnage instead of from entire signature. Enter start and stop Alarm
Window times in msec within Window Time.
Note: In Resolver Model, enter Angle instead of time.

(LOOK) WINDOW TIME (ms) - Only applicable to none Resolver Model
Look Window Time is the duration of time when the force signature and peak tonnage is
captured. The WINDOW TIME need to be adjusted based on the speed of the machine to
capture optimal force signature.

PASTE
Click PASTE button to overwrite the current settings in this screen with the
settings you copy from RECIPE MAIN SCREEN. It is very useful when you
create a new job by duplicating existing job and making some adjustment from
there.

CANCEL
Click CANCEL to cancel any changes you made on this screen and return back
to RECIPE main screen. If you are creating a new job, Clicking CANCEL button
will terminate the creating the job and delete it from the Job Summary Display.

SAVE
Click SAVE button to save the changes you made in this screen. If you are
creating a new job, it will save all settings you entered and add to Job Summary
Display as a new job.

34

PTM LOADGARD Series

Operators Manual

PASSWORD CHANGE
In PASSWORD CHANGE screen, you can set and change the different level of the
passwords.

MASTER PASSWORD
A master level of password can access any password-protected areas. It overrides the
ADMINISTRATOR and OPERATOR level of the passwords and allows you to change their
passwords from this screen. Click MASTER button to change the Master password. This
requires Master level of password.

ADMINISTRATOR PASSWORD
Administrator level of password can access most of the password-protected areas except for
SYSTEM SETUP change in ADTServer. It overrides the OPERATOR level of password and
allows you to change it from this screen. Click ADMINISTRATOR button to change the
Administrator password. This requires Administrator or higher level of password.

OPERATOR PASSWORD
Operator level of password has limited access areas. With Operator level password, you can
change current alarm settings and download the change. However, you cannot alter any
existing jobs in the JOB RECIPE database or create a new job. It only allows you to
download existing job from RECIPE MANAGER screen. Click OPERATOR button to change
the Operator password. This requires Operator or higher level of password.

INITIAL PASSWORD
Master:
Administrator:
Operator:

1968
123456
123

Note: If you forget your passwords, contact HELM INSTRUMENT CO., Inc. at (419) 893-4356

35

PTM LOADGARD Series

Operators Manual

ADTSERVER SETUP SCREEN
ADTServer is the core of the engine for the software of this system. ADTServer receives
tonnage signal from SCM module, processes the data, monitors the alarm conditions, and
handles I/Os. When the system is installed in a machine for the first time, ADTSERVER
requires several initial setups from SYSTEM SETUP screen. Any change of the settings in
ADTSERVER is protected by the Master level of password.

MONITOR SCREEN
Here, you can monitor the current operating status of the ADTSERVER for system trouble
shooting purpose.
FREQUENCY
Sampling speed rate in Hz per Channel
POINTS
Number of sampled points per cycle.
BUFFER CURRENT INDEX
Total number of data stored in buffer per
a cycle.
RESET INPUT
Reset Input Indicator. Turn to red color
when there is reset input.
STROKE COUNT
Displays stroke count after the system is
powered on.
WINDOW TIME (Only applicable to
none Resolver Model)
Displays current Window Time setting.

OPERATING STATUS INDICATOR
IDLE
This indicates that press slide position is out of look window and
ADTSERVER is in idle.
READING
This indicates that press slide position is within look window and
ADTSERVER is sampling data.

OPERATING MODE INDICATOR

OPERATING MODE INDICATOR indicates the system’s current operating mode. Green
background color shows the currently active mode.
Note: Auto means Monitor mode.

36

PTM LOADGARD Series

Operators Manual

SENSOR CALIBRATION SCREEN
Click Calibration button to view a Sensor Calibration screen.
Note: To make any changes of the settings, Master level of password is
required to turn on the Edit Enable Mode.

FRAME SEMSOR screen is to help
calibrating a PTM-1 module to get a proper
reading from the load sensors connected.
Each number is a percentage of the voltage
from PTM-1 track out signals for each
channel. 100 means 2.67V which is ideal
voltage to be set as max scale tonnage for a
press. It displays sensor balance numbers
if PTM module’s function switch is in AZ-OFF
position and Cal numbers if the switch is in
CAL position.
For details about PTM function switches,
Please refer to PTM-1 manual.

CALIBRATION SCREEN FOR PTM4500TSM/6700TSM

LINEAR TRANSDUCER screen is to help
calibrating optional Linear Transducer inputs
connected to channel 5 and 6. It is 2 points
calibration. Move slide to maximum position
and enter the measured height to MAX
HEIGHT then Click SET MAX button. Then,
move slide to minimum position and enter
the measured height to MIN HEIGHT then
Click SET MIN
button.
RESOLVER
CALIBRATION
Current ANGLE WITH OFFSET displays the
current position of the resolver with stored
offset applied.
If the current resolver angle read out does
not match with actual machine slide position,
Click Clear Offset to clear any stored Offset
value, click Set New Angle, then enter the
actual angle position of the machine.
This will store new OFFSET value .

37

PTM LOADGARD Series

Operators Manual

SYSTEM SETUP SCREEN
The SETUP screen is where you can configure the initial settings for the system. To make
any changes of the settings, Master level of password is required to turn on the Edit Enable
Mode.

SCALE SET
Scale value is usually set for capacity of the press
divide by number of channel of the frame sensors

TREND ALARM
Use Target In Setup Mode Enable/Disable
This enables or disables the Trend Alarm
feature in Setup and Learn modes.
When enabled, Trend Alarm feature is active in
all modes. In Setup and Learn modes, Trend
Alarm uses Target value as a reference point to
trigger alarm while Sample value is used as the
reference point in Monitor mode. When
disabled, the Target is no longer used and
Trend Alarm feature is only active in Monitor
mode after learning cycle is completed.

TRACKING LOW INHIBIT(%)
This is to ignore the tracking alarm from monitoring the area of the load signature below the set
percentage of the current peak tonnage. For example, the Tracking Low Inhibit is set to 10%
and the current peak load is 90ton, then through out the load signature, any tonnages below 9
ton will not be monitored by tracking alarm.

WINDOW TIME (ms) - Only applicable to none Resolver Model
Look Window Time is the duration of time in msec when the force signature and peak
tonnage is captured. The WINDOW TIME needs to be adjusted based on the speed of the
machine to capture optimal force signature.
PEAK WINDOW (Enable/Disable) - Only applicable to none Resolver Model
If you are interested in monitoring certain part of the signature to capture the peak tonnage
instead of the entire signature, enable PEAK WINDOW option.
When PEAK WINDOW is enabled, you can adjust the monitoring area by using ALARM
WINDOW. The Trend alarm and Tracking alarm will only apply to the PEAK WINDOW area.
However, High Capacity alarm still looks for the actual peak tonnage of entire signature.

38

PTM LOADGARD Series

Operators Manual

System Setup Screen for PTM-5600P/6700P

SCALE SET
Default Scale values for Piezo series are set to 267. We recommend using this value as your
scale set. This will scale the peak load output value to match with the sensor voltage output. For
example, if Ch1 peak shows 157, it means the sensor peak output from PTM Piezo module is
1.57V.

DIVERTER DURATION
Enter a time in msec to adjust the duration how long the Diverter output stays on. When Trend/
tracking/ capacity alarm condition happen, the diverter output turns on for given duration.
You can choose the Diverter output type to be either Normally Open(N.O.) or Normally Closed
(N.C.)
The diverter works for every trend/tracking alarm condition regardless the Fault Delay counter
setting.
CONSECUTIVE FAULT DELAY COUNTER
Enter a number of consecutive fault stroke that required to stop the machine.
When Trend and Tracking alarm condition happens, alarm output does not drop out until the
alarm condition persists consecutively for the number of set cycle.
For example, if the "Consecutive Fault delay counter " is set to 3, When Trend/tracking alarm
condition occurs for 2 continuous strokes and no trend alarm condition in 3rd stroke, the delay
counter reset to 0. Therefore, another 3 continuous trend/tracking alarm conditions have to
happen to trigger Alarm Stop replay or it will run without stopping machine.
* In case of Capacity alarm, system will drop the Alarm Stop relay right away regardless the
Consecutive Fault delay counter setting and turn on diverter for given duration as well.

39

PTM LOADGARD Series

Operators Manual

SYSTEM SETUP SCREEN FOR PTM-4500TSM/6700TSM/6700I-TSM

LOOK WINDOWS
Look Window is the area of the slide position where the force signature and peak
tonnage is captured. The LOOK WINDOW needs to be adjusted to capture optimal
force signature of the machine.
Enter a start angle(degree) where you want to start to monitor the force. By choosing
a multiplier button, it will display the calculated end look window angle automatically.

TREND WARNING OUTPUT LEVEL
Set a percentage of the Tolerance set value where you want to monitor for tonnage
warning condition. When current tonnage reaches or exceeds warning level, the
Tonnage Warning output relay unlatches. When the tonnage returns to normal, the
output relay latches back automatically. For Example, if High Tol is set at 20%, and
Trend Warning Level is set at 50% of Tolerance, when current peak tonnage reaches
or exceeds 50% of Trend indicator (10% from sample peak tonnage), Loadgard
triggers Tonnage Warning output. This gives the way to warn the machine control
prior to tonnage Trend alarm without stopping machine’s operation.
SAVE
Click SAVE button to save any configuration changes on this screen for
ADTSERVER to take effect.

CANCEL
Click on CANCEL button to cancel any configuration changes on this screen
and return to previous screen.

40

PTM LOADGARD Series

Operators Manual

PTM LOADGARD ADC SETUP FOR TSM MODEL




Go To ADC Manager
From Main Menu screen, if you do not see ADC MANAGER menu button, then click on
the hidden button located at the left bottom area of the screen to go to SYSTEM SETUP
MENU. Use 6534 for password
Turn ADC MANAGER option ON and click Save then restart the system.

ADC Manager Setup

a. To enter into the ADC Manager
screen, use master password
(Default mater password “1968”)

41

PTM LOADGARD Series

Operators Manual

b. Click SETUP button to go to ADC Setup screen.

c. In ADC Setup screen, select a SEQ number to 1, select a COMPORT number where the
ADC communication cable is plugged in, and select ASCII PLC ADC MODE option.
d. You can also enter a press name as optional

42

PTM LOADGARD Series


Operators Manual

ADC RS232 CABLE CONNECTION
Direct RS-232 connection is possible with PLC as long as the able length is less than
50feet.
RS-232 Cable connection

43

PTM LOADGARD Series

Operators Manual

GETTING READY FOR CALIBRATION
1.

Make sure proper Look window timing Input is connected to CAM Input of PTM Loadgard.
Please refer to the drawing from the Appendix in the manual for connection details. For TSM
model, Make sure the Resolver is connected properly instead of CAM input

2. Check sensor balance and gain values from the PTM LoadGard,
a. From main menu screen, go to “ADTSERVER SETUP”

b. Click on Monitor tab, and click on Sensor CALIBRATION button.
In this screen, you can verify the current balance and the gain
values of the sensors connected to PTM modules by switching
the 3 position toggle switch on the PTM module inside. OFF
position displays sensor balance, CAL position displays gain
value of the sensor. Please refer to the PTM-1 Module manual
for detail.
Depending on the PTM LOADGARD model, you can calibrate
Resolver angle position or position of Linear input devices in this
screen as well.

PTM-4500 Model

PTM-4500-L2 Model
PTM-4500-TSM Model

c.

For TSM model, you need to calibrate Resolver angle in this screen as well. If the current
resolver angle read out does not match with actual machine slide position, turn Edit option
On by entering master level of password (default: 1968), click Clear Offset to clear any
stored Offset value, click Set New Angle, then enter the actual angle position of the
machine. This will store new OFFSET value.

44

PTM LOADGARD Series

Operators Manual

3. Entering Scale values for each Channel.
Next thing before the calibration, you need to enter proper scale value for each channel.
Scale value is the tonnage that each sensor will measure at full capacity of the machine. For
example, if a machine is rated at 800ton as maximum capacity and has total 4 sensors mounted
on columns of the machine, then the scale value would be 200 ( 800 / 4 = 200) per channel.
To Enter the scale value for each channel,
a. go to “ADTSERVER SETUP”
b. Click on Monitor tab, and click on Setup button
c.

Enable Edit by entering master level of password
(default: 1968)

d. Enter scale value to each channel on SCALE SET
section and click Save.
4. For CAM input model , you need to enter initial Window
Time for calibration.
Look Window Time is the duration of time in
millisecond when the force signature and peak tonnage
is captured. The WINDOW TIME needs to be adjusted
based on the speed of the machine to capture optimal
force signature. For that reason the WINDOW TIME is
one of the job recipe items that can be programmed
for each job.
For initial window time during calibration, set to 500ms
and check the load signature after the first hit on load
cell.
If the load signatures loading duration is less than 25% of the total look window time, then
reduce the Look Window Time.

For TSM model, you need to select Look Window
Angle. Look Window Angle is the area of the stroke in
angle where the force signature and peak tonnage is
monitored and captured.
Unlikely the Look Window Time, the Look Window
Angle does not need to be adjusted per job.
Enter a Look Window Start angle value then select one
of the multiplier (.1, .2, .4, .8. 1.0) to determine the End
angle.
Click Save button to save the changes.

Now the PTM LoadGard is ready to be calibrated. For more details of the features and functions,
please read the PTM LOADGARD User Manual and PTM-1 User Manual.

45

PTM LOADGARD Series

Operators Manual

SYSTEM SPECIFICATIONS

1. 90-240 VAC input power source @ 3.125 Amp.
2. Automatic Zero Balance (Auto-Zero)
3. 2/4/6 channel load-strain gauge input utilizes 175 - 700 ohm nominal bridge resistance.
4. *24VDC-Cam/Prox/PLC input
5. Hi/Lo Gain Range (1 meg/140K)
6. 24VDC I/O
2 inputs : 10-30 VDC
2 outputs : 10-30 VDC
7. Communication Ports
ADC(Automatic Die Change) (RS-422) - Optional
Line Supervisor (ASCII) (RS-422) - Optional
FirstMate (RS-422) - Optional
8.
9. A/D resolution: 16Bit
10. **Resolver Input: Sine/Cosine 12 bit

0.1-degree resolution

11. Speed Range: **3 - 200SPM , *3 - 1000SPM
12. 1 Ethernet port.
13. Interface Display
10.4” TFT LCD Display with 640x480 Resolution w/ Touch Screen.
Windows XP Embedded with Read-Only Filter Enabled to protect OS files
Duel Memory: 4GByte + 2GByte

________________________________________________________________
** : Resolver Input model only
* : CAM Input model only

46

PTM LOADGARD Series

Operators Manual

BYPASS &REMOTE ALARM RESET
OPTION FOR PTM-4500TSM MODEL
PTM-4500TSM model has Remote Alarm reset and Bypass option to bypass Low Trend
and Low Tracking alarm feature while running. This feature is useful for initial setup
procedure after job change while the parts are being fed through a press line.
While bypass is activated during the stroke, Trend alarm, Tracking alarm, and sampling are
disabled. However, Capacity Press Curve alarms are still active to monitor any overload
condition.

TO ENABLE THE BYPASS OPTION
Open “D:\PTM4500TSM\TMONITOR.INI” file using Windows Explorer, set bypass option to
1 as below. Save the file, then restart the system.
[PTM6700i:SYSTEM]
…..
BYPASS OPTION=1
When bypass option is ON, every stroke will be bypassed until BYPASS input is closed
while the silde position is entering Look window start angle set.

47

PTM LOADGARD Series

Operators Manual

ADC ASCII PROTOCOL
This protocol is to communication with the ADC port of the PTM LOADGARD
directly with optional RS422 serial interface for ADC feature.

 Communication Port Setting
BAUD rate:
PARITY:
Data Bits:
Stop Bits:



9600
None
8
1

How to Send Command ASCII DATA

There are 2 types of data protocol. COMMAND DATA and COMFIMATION DATA
1.
2.
3.
4.

Send 9 byte of COMMAND DATA
SCM Autograph will send back 9 byte of data you sent. Wait for the echo data.
Compare the 9 bytes of original data with echoed data for verification.
If both data matches, send COMFIRMATION DATA to complete the command

ASCII Data Format - COMMAND DATA
BYTE#
1
2
3
4
5
6
7
8
9

BYTE DESCRIPTION
ID Byte ( 96 + SCM sequence Number set by DIP switch on the board)
0 (MSByte of Remaining Data Byte to Send)
6 (LSByte of Remaining Data Byte to Send)
218
192
76
203
65
ADC Mode
0 – 250 = Download Job Number
251 = Change to Setup Mode
252 = Change to Monitor Part Mode
253 = Change to Monitor Part Mode
254 = Reset Alarm
255 = No Action

ASCII Data Format - CONFIRMATION DATA
BYTE#
1
2
3
4
5
6
7
8

BYTE DESCRIPTION
ID Byte ( 64 + SCM sequence Number set by DIP switch on the board)
0 (MSByte of Remaining Data Byte to Send)
5 (LSByte of Remaining Data Byte to Send)
218
192
76
203
85

48

PTM LOADGARD Series

Operators Manual

Example)
To change the mode to Setup mode for SCM module which is set as Seq#1,
1. Send 9 bye of data below
97, 0, 6,218, 192, 76, 203, 65, 251
2. Wait for response data (9byte) from SCM Autograph
3. compare the data received and the data you sent to see if all matches.
4. If both data matches, send COMFIRMATION DATA to complete the command as below
65, 0, 5, 218, 192, 76, 203, 85

49

PTM LOADGARD Series

Operators Manual

APPENDIX A ( PTM-4500L2 ) - 4CH FRAME WITH 2 LINEAR TRANSDUCER

50

PTM LOADGARD Series

Operators Manual

APPENDIX B ( PTM-2300L ) – 2CH FRAME/INDIE WITH 1 LINEAR TRANSDUCER INPUT

51

PTM LOADGARD Series

Operators Manual

APPENDIX C ( PTM-6700I ) – 6CH IN-DIE APPLCATION

52

PTM LOADGARD Series

Operators Manual

APPENDIX D ( PTM-5600F ) – 3CH IN-DIE + 2CH FRAME APPLICATION

53

PTM LOADGARD Series

Operators Manual

APPENDIX E ( PTM-6700TSM ) 4CH FRAME + 2CH INDEA WITH RESOLVER INPUT

54

PTM LOADGARD Series

Operators Manual

APPENDIX F ( PTM-4400I ) 4CH IN-DIE APPLICATION

55

PTM LOADGARD Series

Operators Manual

APPENDIX G ( PTM-4500TSM )- 4CH FRAME WITH RESOLVER INPUT

56

PTM LOADGARD Series

Operators Manual

APPENDIX H ( PTM-4500TSM-ASA )- 4CH FRAME + AUTO SHUTHEIGHT ADJUST W/ RESOLVER
INPUT

57

PTM LOADGARD Series

Operators Manual

APPENDIX I ( PTM-5600P) - 5CH PIEZO SENSOR INPUT

58

PTM LOADGARD Series

Operators Manual

APPENDIX J ( PTM-4500) - 4CH FRAME WITH CAM INPUT

59

PTM LOADGARD Series

Operators Manual

APPENDIX K ( PTM-4500-ADC) - 4CH FRAME WITH AUTOMATIC DIE CHANGE OPTION

60

PTM LOADGARD Series

Operators Manual

APPENDIX L LINE SUPERVISOR WITH RLG CONENCTION

61

PTM LOADGARD Series

Operators Manual

APPENDIX M ( PTM-6100-SS) - 4CH FRAME, 1CH IN-DIE, 1CH LASER SENSOR

62

PTM LOADGARD Series

Operators Manual

APPENDIX N ( PTM-6700I-TSM) - 6CH IN-DIE WITH TREND WARNING OUTPUT

63

PTM LOADGARD Series

Operators Manual

APPENDIX O PTM LOADGARD DIMEMSION (STANDARD MOUNT)

64

PTM LOADGARD Series

Operators Manual

APPENDIX P PTM LOADGARD DIMEMSION (FLANGE MOUNT)

65

PTM LOADGARD Series

Operators Manual

APPENDIX P-1 PTM LOADGARD PANEL PC CONNECTIONS LAYOUT

66

PTM LOADGARD Series

Operators Manual

APPENDIX Q (PTM-884TSM-SS) 4CH FRAME, 4CH IN-DIE SENSORS

67

PTM LOADGARD Series

Operators Manual

APPENDIX R (PTM-844TSM-SS) CONNECTION DRAWING

68

PTM LOADGARD Series

Operators Manual

APPENDIX S (PTM-1248TSM-SS) 4CH FRAME, 8CH IN-DIE SENSORS

69

PTM LOADGARD Series

Operators Manual

APPENDIX T (PTM-1248TSM-SS) CONNECTION DRAWING

70

PTM LOADGARD Series

Operators Manual

APPENDIX U RLG LINE SUPERVISOR CONNECTION

71

PTM LOADGARD Series

Operators Manual

APPENDIX V PTM-102L CONNECTIONS

72

PTM LOADGARD Series

Operators Manual

APPENDIX W PTM-4500TSM NEW I/O BOARD CONNECTIONS

73

PTM LOADGARD Series

Operators Manual

APPENDIX X PTM-6600TSM FOR DOULE ACTION CONNECTIONS

74

PTM LOADGARD Series

Operators Manual

APPENDIX Y PTM-8800TSM FOR DOULE ACTION CONNECTIONS

75

PTM LOADGARD Series

Operators Manual

APPENDIX Z PTM-2300D-TSM WITH DIVERTER OUTPUT

76

PTM LOADGARD Series

Operators Manual

APPENDIX Z1 PROFINET ADD-ON KIT CONNECTION

77



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 80
Language                        : en-US
Tagged PDF                      : Yes
Title                           : The Autograph Monitor Screens contain the most common information for the operator
Author                          : Dave Galvin
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2015:08:20 11:19:29-04:00
Modify Date                     : 2015:08:20 11:19:29-04:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools

Navigation menu