200102 Raad
User Manual: 200102
Open the PDF directly: View PDF
.
Page Count: 41
| Download | |
| Open PDF In Browser | View PDF |
2005 Products Catalog In The Name of God MODULAR TERMINAL BLOCKS Confidenc in Connection Photo & Design: Gilar +9821 8830988 RAAD Raad Manufacturing Company was founded in 1988 as a designer and producer of different kinds of molds. In 1992, the company expanded its activities and continued as an OEM in modular terminal block industry. Since the beginning of its operation, Raad has maintained and improved close cooperative relation with its customers and taken benefit of their views and feedbacks. Key strategies such as enhancing customers satisfaction, applying highly productive technological processes and using Contents The Company Product overview 4 RTP series terminal blocks 9 Protective conductor terminal blocks 15 Double level terminal blocks 19 Test disconnect terminal blocks 27 Fuse terminal blocks 33 Coloured terminal blocks 39 RTM series terminal blocks 41 RCT series terminal blocks 47 Accessories 55 General technical information 67 the best quality materials and parts, are all the company's policies which define its approach to development and open the doors into new discoveries in the field. Today, thanks to several approvals obtained world-wide by its products, having had comprehensive range of products, Raad is, honorably, the leading manufacturer of terminal blocks in Middle East. The company’s headquarter and sales division is located in Tehran and the manufacturing site is practicing in a rural area of Isfahan, employing over 200 well-trained and skilled personnel. Raad Manufacturing Co. reserves the right to make changes to any information given in this catalog regarding technical progresses. Please contact us for update technical information and new prices. Headquarter and sales division North 3rd floor, 28, 2nd St. Shahnazari St., Madar Sq., Mirdamad Blv. Tehran - Iran Tel. +98 21 227 8455 - 6 Fax +98 21 227 8457 salse@raad-co.com www.raad-co.com Factory 20th St., Azadegan freeway Isfahan - Iran PO Box 81395/111 Tel. +98 311 3802026 Fax +98 311 3802013 info@raad-co.com RTP Series Terminal Blocks RTP 4/ Page 10 RTP 6 / Page 11 RTP 10 / Page 11 DRTP4-D4 / Page 23 DRTP4-D5 / Page 23 DRTP4-D6 / Page 24 DRTP4-DR1 / Page 25 DRTP4-DR2 / Page 25 DRTP4-LD / Page 26 DRTP4-NL / Page 26 Test Disconnect Terminal Blocks RTP 2.5 / Page 10 RTP 25 / Page 12 RTP 35 / Page 13 RTP 50 / Page13 RCT-L2 / Page 28 RET 2.5 / Page 16 RET 4 / Page 16 RCT-LU2 / Page 28 RST6 / Page 29 RTT6 / Page 29 RDT4 / Page 30 Fuse Terminal Blocks RTP 95 / Page 14 Product Over view M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Protective Conductor Terminal Blocks RTP 16 / Page 12 4 RET 10 / Page 17 DRTP4 / Page 20 DRTP4-D1 / Page 21 RET 16 / Page 18 RET 35 / Page 18 DRTP4-D2 / Page 22 DRTP4-D3 / Page 22 RDT4-TS / Page 30 STC6 / Page 31 RCTF10 / Page 34 RCTF10-NL / Page 34 Double Level Terminal Blocks RET 6 / Page 17 5 RCTF10-LD / Page 35 RFT5 / Page 36 RFT5-NL / Page 36 RFTS-LD / Page 37 RTM Series Terminal Blocks Accessories RTM2.5 / Page 42 RTM6 / Page 43 RTM25 / Page 44 RTM35 / Page 45 RTM10 / Page 43 RTM50 / Page 45 NS6 / Page 56 LB/1 / Page 57 NS6.4 / Page 56 LB/2 / Page 57 NS8 / Page 56 End Plates & Partition / Page 60 COVER / Page 60 RCT Series Terminal Blocks RCT4 / Page 48 RCT6 / Page 48 RCT16 / Page 49 RCT35 / Page 49 Cross-Connection / Page 62 TEST SOCKET / Page 64 MOVEABLE LINK / Page 64 MOUNTING RAILS / Page 65 Product Over view M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 RTM16 / Page 44 RTM4 / Page 42 6 7 RCT50 / Page 50 RCT150 / Page 52 RCT70 / Page 51 RCT95 / Page 51 RCT185 / Page 53 RCT120 / Page 52 RCT240 / Page 53 MOUNTING RAILS ACCESSORIES / Page 66 EB/1 / Page 66 EB/2 / Page 66 EB32 / Page 66 TERMINAL BLOCKS S E R I E S R T P Raad offers the RTP series with the following advantages: Combination foot for both TH35 and G32 mounting rails Terminal insulation body polyamide 6.6 Easy to tighten due to screwdriver guide Closed cable entry for preventing from wire splitting Best connection of the conductor, needing no special cable preparation Appropriate for different cross-sections, rigid or flexible Similar end plates and patition for several types Preassembled and divisible cross-connection system and easy removable unwanted cross-connection Offering protective conductor terminals, suitable for various sizes of terminals Having 10 marker strips simultaneously mountable on some sizes of the terminal Certified by notorious national institutes RTP2.5 RTP4 width 6 mm K width 6.4 mm EMA EUR K EMA EUR RTP6 RTP10 width 8 mm width 10 mm K VDE EMA EUR K EMA EUR Reg.-No. 130597 Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 10 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 End plate width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection RTP2.5 Test socket Marking 1 2 3 RTP4 500/6 3/III/I 24 2.5 500/6 3/III/I 32 4 Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 101001 100 201001 100 201005 100 SP-2.5-10 201007 100 EB32 8 200101 50 EP-RTP2.5 1.5 P-RTP2.5 1.5 max. current (A) RTP2.5 Type RTP4 101003 100 201003 50 201008 50 SP-2.5-10 201007 100 EB32 9.5 200101 50 EP-RTP4,6,10 1.5 P-RTP4,6,10 1.5 EB/1 200102 50 EB/1 200102 50 9.5 9.5 CC10-2.5 10-pos. 201020 10 CC10-4 10-pos. 201023 10 CC3-2.5 3-pos. 201021 50 CC3-4 3-pos. 201024 50 CC2-2.5 2-pos. 201022 50 CC2-4 2-pos. 201025 50 20 32 TS3/6/2.3 TS3/6/2.3 200540 50 200540 50 NS6 For details see Accessories NS6.4 For details see Accessories Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material RTP6 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 End plate width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection RTP6 Test socket Marking 1 2 3 800/8 3/III/I 57 10 O rdering No. Q t y. 101005 50 201003 50 201008 50 SP-2.5-10 201007 100 EB32 8 200101 50 EP-RTP4,6,10 1.5 P-RTP4,6,10 1.5 max. current (A) RTP10 800/8 3/III/I 41 6 Type O rdering No. Q t y. RTP10 101007 50 201003 50 201008 50 SP-2.5-10 201007 100 EB32 8 200101 50 EP-RTP4,6,10 1.5 P-RTP4,6,10 1.5 EB/1 200102 50 9.5 CC10-6 10-pos. 201026 10 CC3-6 3-pos. 201027 50 CC2-6 2-pos. 201028 50 47 TS3/8/4 200541 50 NS8 For details see Accessories EB/1 200102 50 9.5 CC10-10 10-pos. 201029 10 CC3-10 3-pos. 201030 50 CC2-10 2-pos. 201031 50 47 TS3/8/4 200541 50 NS8 Raad recommended For details see Accessories 8/45.6 10/45.6 51.3/47.4/54.9 51.3/47.4/54.9 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5 1.2 PA 6.6 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 PA 6.6 Dimensions (mm) 6/45.5 6.4/45.6 45.7/41.5/49 51.3/47.4/54.9 0.5-4 0.5-4 0.5-2.5 20-12 A3 10 M2.5 0.4 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 12 M3 0.5 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC 60947-7-1 rated data Width/Length Hight, G32/TH 35-7.5/TH 35-15 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material R T P S ERIES IEC 60947-7-1 rated data 11 RTP16 RTP25 RTP35 R T P 50 width 12.5 mm width 13.6 mm width 16.5 mm width 20.1 mm EMA EUR K IEC 60947-7-1 rated data Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) Description Type M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Partition width (mm) Small Partition no loss of pitch 12 End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 EMA EUR K EMA EUR RTP16 RTP25 800/8 3/III/I 76 16 800/8 3/III/I 101 25 Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. Type IEC 60947-7-1 rated data RTP16 101009 50 RTP25 101011 50 GP 3 201103 20 GP 3 201103 20 SP-16-35 201101 50 SP-16-35 201101 50 EB/1 9.5 200102 50 EB/1 9.5 200102 50 EB/2 200103 50 10 CC10-16 10-pos. 201120 10 CC3-16 3-pos. 201121 20 CC2-16 2-pos. 201122 20 47 TS3.5/8/4 200542 50 NS8 Raad recommended For details see Accessories EB/2 200103 50 10 CC10-25 10-pos. 201123 10 CC3-25 3-pos. 201124 20 CC2-25 2-pos. 201125 20 65 TS4/8/4 200543 50 NS8 Raad recommended For details see Accessories Dimensions (mm) End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 EMA EUR RTP35 RTP50 800/8 3/III/I 125 35 1000/8 3/III/I 150 50 O rdering No. Q t y. Type O rdering No. Q t y. RTP35 101013 20 RTP50 101015 20 GP 3 201103 20 GP 3 201103 20 SP-16-35 201101 50 SP-50 201102 50 EB/1 9.5 200102 50 EB/2 EB/2 200103 50 200103 50 10 10 CC10-35 10-pos. 201126 10 CC3-50 3-pos. 201129 10 CC3-35 3-pos. 201127 20 CC2-50 2-pos. 201130 10 CC2-35 2-pos. 201128 20 65 180 TS4/8/4 200543 50 NS8 Raad recommended For details see Accessories NS8 Raad recommended For details see Accessories CP50 201180 50 Dimensions (mm) Width/Length 12.5/49.8 13.6/49.8 Width/Length Hight, G32/TH 35-7.5/TH 35-15 65/61/68.5 65/61/68.5 Hight, G32/TH 35-7.5/TH 35-15 0.5-16 0.5-16 0.5-16 20-4 B7 12.3 M5 2.5 PA 6.6 0.5-16 0.5-25 0.5-25 20-3 B8 12.3 M5 2.5 PA 6.6 Connection capacity IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Partition width (mm) Small partition no loss of pitch Protection cover Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) K 16.5/51.4 20.1/67.8 67.6/63.5/71 73.5/69.5/77 1.5-16 1.5-35 1.5-35 14-1 B9 14.9 M6 3.5 PA 6.6 6-16 6-50 10-50 8-0 B10 19 M8 4.5 PA 6.6-V0 on request Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material R T P S ERIES K 13 RTP95 Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) Description M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Terminal block, for mounting on G 32 ,TH 35-15 Terminal block, for mounting on TH 35 -15, 2.3 thickness End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection 14 max. current (A) Marking 1 2 3 1000/8 3/III/I 232 95 Type O rdering No. Q t y. RTP95 102018 5 RTP95 102019 5 EB/2 10 CC3-95 3-pos. CC2-95 2-pos. 232 NS8 Raad recommended 200103 50 201218 201219 10 10 For details see Accessories TERMINAL BLOCKS IEC 60947-7-1 rated data PROTECTIVE CONDUCTOR RTP95 width 25 mm Moutable on both TH35 and G32 mounting rails, beside other types of terminals Having green - yellow, partially insulated, cases made of polyamide 6.6 Designed to provide proper electrical and mechanical connection with its mounting rail, so that it can be used as a protective conductor busbar Protective conductor terminal blocks share the same space-saving characteristic and design specifications as the RTP series Used for connecting PE and PEN conductors, regarding the rated cross - section to be more than 10 mm for PEN function, as specified in the below table Dimensions (mm) Width/Length 25/90.2 Hight, G32/TH 35-15 97.3/101 IEC 60947-7-2 Connection capacity Solid (mm2) 6-95 Multi stranded (mm2) 6-95 Flexible (mm2) 10-95 American Wire Gauge (AWG) 8-4/0 IEC test gauge B12 Stripping Iength (mm) 24.5 Clamping screw M8 Tightening torque (N.m) Insulation material Table A.1 - Maximum short - time withstand currents allocated to the rail profile and thermal rated current of a PEN busbar 12-14 PA 6.6 - V0 on request Short-time Thermal rated withstand current current of a PEN 1s busbar kA A “Top hat” rail Steel ** 10 1.2 IEC 607 15/TH 15-5.5 Copper * 25 3 101 Aluminium * 16 1.92 76 G-type rail Steel ** 35 4.2 IEC 607 15/G32 Copper * 120 14.4 269 Aluminium * 70 8.4 192 “Top hat” rail Steel ** 16 1.92 IEC 607 15/TH 35-7.5 Copper * 50 6 150 Aluminium * 35 4.2 125 “Top hat” rail Steel ** 50 6 IEC 607 15/TH 35-15 Copper * 150 18 309 Aluminium * 95 11.4 232 * Copper or aluminium alloys selected by the manufacturer of terminal block assembly to achieve the values in the table. ** Steel protective conductor busbars are not allowed to be used as a PEN conductor. Rail profile Material Equivalent E-Cu cross-section mm2 R ET 2 .5 RET4 width 6 mm Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) Description Type RET4 6 3/III/I 2.5 6 3/III/I 4 Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. RET 2.5 1 2 3 Width/Length NS6 101201 50 For details see Accessories Type RET 4 NS6.4 101202 45.7/41.5/49 51.3/47.4/54.9 0.5-4 0.5-4 0.5-4 0.5-4 Flexible (mm ) 0.5-2.5 0.5-4 American Wire Gauge (AWG) 20-12 20-12 A3 A4 10 12 M2.5/0.4 M3/0.5 M3/0.5 M3/0.5 PA 6.6 PA 6.6 Connection capacity 2 Multi stranded (mm ) 2 IEC test gauge Stripping Iength (mm) Clamping screw/Tightening torque (N.m) Center screw/Tightening torque (N.m) Insulation material 50 Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Marking Type RET6 RET10 8 3/III/I 6 8 3/III/I 57 10 O rdering No. Q t y. RET 6 1 2 3 NS8 101203 25 Type O rdering No. Q t y. RET 10 101204 25 For details see Accessories NS8 Raad recommended For details see Accessories Dimensions (mm) 6.4/45.6 Solid (mm2) IEC 60947-7-2 rated data For details see Accessories 6/45.5 Hight, G32/TH 35-7.5/TH 35-15 M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 width 10 mm RET2.5 Dimensions (mm) 16 R E T 10 width 8 mm Width/Length 8/45.6 10/45.6 51.3/47.4/54.9 51.3/47.4/54.9 0.5-10 0.5-16 0.5-10 0.5-16 Flexible (mm ) 0.5-6 0.5-10 American Wire Gauge (AWG) 20-8 20-6 A5 B6 12 12 M3.5/1.2 M4/1.5 M4/1.2 M4/1.2 PA 6.6 PA 6.6 Hight, G32/TH 35-7.5/TH 35-15 Connection capacity Solid (mm2) 2 Multi stranded (mm ) 2 IEC test gauge Stripping Iength (mm) Clamping screw/Tightening torque (N.m) Center screw/Tightening torque (N.m) Insulation material P R OT E C T IV E C ON DU C TOR T E R M INAL BL O CKS IEC 60947-7-2 rated data Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Marking RET6 width 6.4 mm 17 Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) Description Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Marking Type RET16 RET35 8 3/III/I 76 16 8 3/III/I 125 35 O rdering No. Q t y. RET 16 1 2 3 101205 20 Type O rdering No. Q t y. RET 35 101206 NS8 Raad recommended For details see Accessories NS8 Raad recommended For details see Accessories M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Dimensions (mm) 18 Width/Length 12.2/49.8 16.5/51.4 Hight, G32/TH 35-7.5/TH 35-15 65/61/68.5 67.6/68.5/71 0.5-16 1.5-35 0.5-16 1.5-35 0.5-16 1.5-35 20-4 14-1 Connection capacity Solid (mm2) 2 Multi stranded (mm ) 2 Flexible (mm ) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw/Tightening torque (N.m) Center screw/Tightening torque (N.m) Insulation material 20 B7 B9 12.3 14.9 M5/2.5 M6/3.5 M4/1.2 M5/2 PA 6.6 PA 6.6 TERMINAL BLOCKS IEC 60947-7-2 rated data L E V E L RET35 width 16.5 mm D O U B L E RET16 width 12.5 mm Raad double level terminal blocks enjoy the spase-saving advantage. It is remarkable in this type of terminal that the upper level is offset laterally by half of the terminal block width. The following advantages are met, due to the double wiring density: Accessibility of the lower level screw is more effective with a screw driver and Lower labels and entry points can be viewed better The EP3 end plate and the EP2 end plate compensates for the level offset at the beginning and the end of the terminal strips, so that standard terminal blocks can be directly aligned. As for foot connection, they can be mounted on either of the TH 35 or G 32 mounting rails. DRTP4-D1 width 6.4 mm IEC 60947-7-1 rated data DRTP4 Voltage(V)/Impulse voltage (kV) Pollution degre/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 20 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. DRTP4 101302 50 EP1-DRTP4 201302 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 200103 EB/2 50 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 32 TS3/6/2.3 200540 NS6.4 For details see Accessories Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material DRTP4-D1 Voltage (VAC) Diode reverse voltage (V) Current (A) Diode current (A) Diode Cross - section (mm2) 400 1000 32 1 1N4007 4 Description Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. DRTP4-D1 101310 50 EP1-DRTP4 201302 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 200103 EB/2 50 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 32 TS3/6/2.3 200540 NS6.4 For details see Accessories In designing DRTP4, Special capabilities are offered for installing electronic elements. Raad double level terminal blocks are used for voltage rectifying, monitoring, fine switching, and test circuits. Furthermore, a number of circuits, in which the terminal are applied, are offered. Any other type of circuit is offered on request. + ~ - Example for rectifying purposes Example for displying protection status + - 21 Example for fine switching a DC load 6.4/68.4 71.5/67.5/75 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC 60947-7-1 rated data 500/6 3/III/I 32 4 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 6.4/68.4 71.5/67.5/75 + 24 V TEST Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 DOUBLE LEVEL TERMINAL BLOCKS DRTP4 width 6.4 mm 0V Example for lamp test circuit DRTP4-D3 DRTP4-D4 DRTP4-D5 width 6.4 mm width 6.4 mm width 6.4 mm width 6.4 mm IEC 60947-7-1 rated data DRTP4-D2 DRTP4-D3 400 1000 1 1N4007 4 400 1000 1 1N4007 4 Voltage (VAC) Diode reverse voltage (V) Current (A) Diode current (A) Diode Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 22 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 Freewheeling diode for DC loads End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. Type Hight, G32/TH 35-7.5/TH 35-15 DRTP4-D2 101311 50 DRTP4-D3 101312 50 EP1-DRTP4 201302 20 EP1-DRTP4 201302 20 EP2-DRTP4 201303 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 SP-2.5-10 201007 100 EB/2 200103 50 EB/2 200103 50 10 10 CC10-D4 10-pos. 201310 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 CC2-D4 2-pos. 201312 50 32 32 TS3/6/2.3 200540 50 TS3/6/2.3 200540 50 NS6.4 NS6.4 For details see Accessories For details see Accessories IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material DRTP4-D5 400 1000 1 1N4007 4 400 1000 1 1N4007 4 Description Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 for lamp test circuit End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. Type O rdering No. Q t y. DRTP4-D4 101313 50 DRTP4-D5 101314 50 EP1-DRTP4 201302 20 EP1-DRTP4 201302 20 EP2-DRTP4 201303 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 SP-2.5-10 201007 100 EB/2 200103 50 EB/2 200103 50 10 10 CC10-D4 10-pos. 201310 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 CC2-D4 2-pos. 201312 50 32 32 TS3/6/2.3 200540 50 TS3/6/2.3 200540 50 NS6.4 NS6.4 For details see Accessories For details see Accessories Dimensions (mm) 6.4/68.4 6.4/68.4 71.5/67.5/75 71.5/67.5/75 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) DRTP4-D4 Voltage (VAC) Diode reverse voltage (V) Current (A) Diode current (A) Diode Cross - section (mm2) O rdering No. Q t y. Dimensions (mm) Width/Length IEC 60947-7-1 rated data Width/Length Hight, G32/TH 35-7.5/TH 35-15 6.4/68.4 6.4/68.4 71.5/67.5/75 71.5/67.5/75 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material DOUBLE LEVEL TERMINAL BLOCKS DRTP4-D2 23 DRTP4-DR1 DRTP4-DR2 width 6.4 mm width 6.4 mm width 6.4 mm IEC 60947-7-1 rated data DRTP4-D6 Voltage (VAC) Diode reverse voltage (V) Current (A) Diode current (A) Diode Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 24 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 for lamp test circuit End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection DRTP4-D6 1 2 3 O rdering No. Q t y. 101315 201302 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 201007 Hight, G32/TH 35-7.5/TH 35-15 6.4/68.4 71.5/67.5/75 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 DRTP4-DR1 DRTP4-DR2 24 1000 1 1N4007 1.5kΩ 4 24 1000 1 1N4007 1.5kΩ 4 Voltage (VDC) Diode reverse voltage (V) Current (A) Diode current (A) Diode Resistor Cross - section (mm2) Description Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 for lamp test circuit with resistor End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. Type O rdering No. Q t y. DRTP4-DR1 101316 50 DRTP4-DR2 101317 50 EP1-DRTP4 201302 20 EP1-DRTP4 201302 20 EP2-DRTP4 201303 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 SP-2.5-10 201007 100 EB/2 200103 50 EB/2 200103 50 10 10 CC10-D4 10-pos. 201310 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 CC2-D4 2-pos. 201312 50 32 32 TS3/6/2.3 200540 50 TS3/6/2.3 200540 50 NS6.4 NS6.4 For details see Accessories For details see Accessories Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) 100 EB/2 200103 50 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 32 TS3/6/2.3 200540 50 NS6.4 For details see Accessories Dimensions (mm) Width/Length 50 EP1-DRTP4 SP-2.5-10 max. current (A) Test socket Marking IEC 60947-7-1 rated data 400 1000 1 1N4007 4 6.4/68.4 6.4/68.4 71.5/67.5/75 71.5/67.5/75 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material DOUBLE LEVEL TERMINAL BLOCKS DRTP4-D6 25 width 6.4 mm IEC 60947-7-1 rated data DRTP4-LD DRTP4-NL 24VDC <5mA 4 115-230VAC <5mA 4 Voltage LED or Neon lamp current Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 26 Type Terminal block, for mounting on G 32 ,TH 35-7.5, 15 DC and AC voltage indicator End plate 1 width (mm) End plate 2 width (mm) End plate 3 width (mm) Partition width (mm) Small partition no loss of pitch End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking 1 2 3 O rdering No. Q t y. Type O rdering No. Q t y. DRTP4-LD DC voltage indicator 101318 50 DRTP4-NL AC voltage indicator 101319 50 EP1-DRTP4 201302 20 EP1-DRTP4 201301 20 EP2-DRTP4 201303 20 EP2-DRTP4 201303 20 EP3-DRTP4 201304 20 EP3-DRTP4 201304 20 P-DRTP4 200302 20 P-DRTP4 200302 20 SP-2.5-10 201007 100 SP-2.5-10 201007 100 EB/2 200103 50 EB/2 200103 50 10 10 CC10-D4 10-pos. 201310 10 CC10-D4 10-pos. 201310 10 CC3-D4 3-pos. 201311 50 CC3-D4 3-pos. 201311 50 CC2-D4 2-pos. 201312 50 CC2-D4 2-pos. 201312 50 32 32 TS3/6/2.3 200540 50 TS3/6/2.3 200540 50 NS6.4 NS6.4 For details see Accessories For details see Accessories Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 6.4/68.4 6.4/68.4 71.5/67.5/75 71.5/67.5/75 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 9 M2.5 0.4 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material TERMINAL BLOCKS DRTP4-NL TEST DISCONNECT DRTP4-LD width 6.4 mm 1 K 2 3 4 l K 5 6 7 l K 8 9 10 11 12 13 l L1 L2 L3 N L1 1 2 3 4 5 6 7 8 9 10 K l K l K l L1 L2 L3 N L1 L2 L2 L3 L3 N N Wattmeter test circuit, designed with 13 RCT-L2 and RCT-LU2 Wattmeter test circuit, designed with 10 RST6 and RTT6 In measuring, control and remote - controlled systems test and disconnect terminals are often installed. A typical circuit can be considered for each of the above mentioned items.RCTL2, RCTLU2, STC6, and new types such as RST6, RTT6, RDT4, accompanied by their relating accessories, can be mounted in all types of circuits specified in this field, including secondary circuits for current transformers. RCT-L2 RCT-LU2 RST6 RTT6 width 8 mm width 8 mm width 8 mm width 8 mm IEC 60947-7-1 rated data Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 28 Test disconnect terminal, for mounting on G 32 End plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Moveable cross-connection, for 2 terminal blocks, with 2 test socket screws and 2 sleeves max. current (A) Moveable cross-connection, for 4 terminal blocks, with 4 test socket screws and 4 sleeves max. current (A) Moveable cross-connection, for 2 terminal blocks, with 2 screws and 2 sleeves max. current (A) Moveable cross-connection, for 4 terminal blocks, with 4 screws and 4 sleeves max. current (A) Test socket Marking Type RCT-L2 EP-L2,LU2 2 EB32 8 EB/1 9.5 ML2A R C T -L2 R C T -LU2 400/6 3/III/I 32 6 400/6 3/III/I 32 6 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 100902 50 200710 50 200101 50 200102 50 200706 100 24 ML4A 1 2 3 Type RCT-LU2 EP-L2,LU2 2 EB32 8 EB/1 9.5 ML2A 200707 50 ML4A 100901 50 200710 50 200101 50 200102 50 200706 100 200707 50 200701 100 ML2B 200701 100 24 ML4B ML4B 200702 200703 50 50 For details see Accessories 24 TS3/14/4 NS6 200702 50 200703 50 For details see Accessories max. current (A) End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Marking Width/Length/Hight, G32 IEC test gauge Stripping Iength (mm) Clamping screw/Tightening torque (N.m) Center screw/Tightening torque (N.m) Insulation material 400/6 3/III/I 32 6 O rdering No. Q t y. O rdering No. Q t y. RST6 100912 20 RTT6 100913 20 ML2N 200708 50 ML2N 200708 50 200709 50 32 ML3N 200709 50 32 CC10-6 CC3-6 CC2-6 32 10-pos. 3-pos. 2-pos. 47 EB/1 9.5 NS8 ML3N 32 ML4N 1 2 3 Type 200712 25 ML4N 200712 25 201026 201027 201028 10 50 50 32 CC10-6 10-pos. CC3-6 3-pos. CC2-6 2-pos. 47 201026 201027 201028 10 50 50 200102 50 200102 50 For details see Accessories EB/1 9.5 NS8 For details see Accessories 29 Dimensions (mm) Width/Length 8/107 8/107 65/61.5/69 65/61.5/69 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5/1.2 M3/0.5 PA 6.6 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5/1.2 PA 6.6 Connection capacity 8/64/52.5 8/64/52.5 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5/1.2 M3/0.5 PA 6.6 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5/1.1 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) RTT6 400/6 3/III/I 32 6 32 Hight, G32/TH 35-7.5/TH 35-15 Dimensions (mm) RST6 Type Test disconnect terminal, for mounting on G 32 TH 35-7.5,15 Moveable cross-connection, for 2 terminal blocks, with 2 screws max. current (A) Moveable cross-connection, for 3 terminal blocks, with 3 screws max. current (A) Moveable cross-connection, for 4 terminal blocks, with 4 screws max. current (A) Cross-connection 24 24 24 TS3/14/4 NS6 IEC 60947-7-1 rated data 24 24 ML2B EMA EUR Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw/Tightening torque (N.m) Center screw/Tightening torque (N.m) Insulation material T E S T D I S C O N N E C T T E R M I NAL B L O CK S K RDT 4 RDT4-TS STC6 width 6.4 mm width 6.4 mm width 6.4 mm Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) Description Type M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Test disconnect terminal, for mounting on G 32 TH 35-7.5,15 End plate width (mm) 30 End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Bridge-comb max. current (A) Marking RDT4 RDT4 R D T4-TS 500/6 3/III/I 17 . 5 4 500/6 3/III/I 17 . 5 4 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 101401 50 Type RDT4-TS 101401 IEC 60947-7-1 rated data 50 with socket screw EP-RDT4 EB32 8 1 2 3 200404 200101 100 50 EB/1 200102 50 9.5 BC10-4 10-pos. 201410 10 12 For details see Accessories NS6.4 EP-RDT4 200404 100 EB32 8 200101 50 EB/1 9.5 BC10-4 12 NS6.4 200102 50 201410 10 For details see Accessories Disconnect terminal, for mounting on G 32 End plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Marking STC6 500/6 3/III/I 24 4 Type 1 2 3 O rdering No. Q t y. STC6 100701 100 EP-STC6 1.5 EB32 8 200401 100 200101 50 EB/1 9.5 NS6 200102 50 For details see Accessories Dimensions (mm) Width/Length/Hight, G32 6.4/39.5/66 Connection capacity Dimensions (mm) Width/Length Hight, G32/TH 35-7.5/TH 35-15 6.4/49 6.4/49 51.3/47.4/54.9 51.3/47.4/54.9 0.5-4 0.5-4 0.5-4 20-12 A4 12 M3 0.5 PA 6.6 0.5-4 0.5-4 0.5-4 20-12 A4 12 M3 0.5 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material 0.5-4 0.5-4 0.5-4 20-12 A4 12 M3 0.5 PA 6.6 T E S T D I S C O N N E C T T E R M I NAL B L O CK S IEC 60947-7-1 rated data 31 TERMINAL BLOCKS F U S E F U S E T E R M I NA L B L O C K S In accordance with the electrical standards, all electrical equipment control systems and machines must be protected with fuse cartridges, thus fuse terminal blocks have been developed to meet these standards and requirements. The technical data of the fuse terminal blocks, for the protection of electrical devices, is bound to the application and the use of products. In RCTF type, the fuse cartridge is inserted in terminal block together with the screw cap. The terminal block is furnished with a light indicator which signalizes when the fuse blows. The RFT type holds different segments: The base terminal block and the upper hinged-type fuse carrier. The RFT type is equipped with indicator light, RCTF type alike, functioning similarly. Another advantage of the RFT type which distinguishes it from other types is its bonus to carry a spare fuse cartridge inside the terminal cartridge. RCTF10 RCTF10-NL RCTF10-LD RCTF10-LD width 13 mm width 13 mm width 13 mm width 13 mm Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 34 Fuse terminal block, without indicator, for mounting on G 32 , for fuse cartridge 5*20 and 5*25mm Fuse terminal block, with neon lamp, for mounting on G 32 , for fuse cartridge 5*20 and 5*25mm End plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Test socket Type RCTF10 R CTF10 R CTF10- N L 400/6 3/III/I 6.3 10 3/III/I 6.3 10 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 100801 Type 20 RCTF10-NL 110-250VAC EP-RCTF10 3 EB32 8 EB/1 9.5 TS3/8/4 IEC 60947-7-1 rated data 200901 20 200101 50 200102 50 200541 50 EP-RCTF10 3 EB32 8 EB/1 9.5 100802 20 200901 20 200101 50 200102 50 Fuse terminal block, with LED, for mounting on G 32 , for fuse cartridge 5*20 and 5*25mm End plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended R CTF10-LD R CTF10- L D 3/III/I 6.3 10 3/III/I 6.3 10 Type RCTF10-LD 24VDC,48VAC EP-RCTF10 3 EB32 8 EB/1 9.5 O rdering No. Q t y. 100803 20 200901 20 200101 50 200102 50 Type RCTF10-LD 40-60VDC, 80-120VAC EP-RCTF10 3 EB32 8 EB/1 9.5 O rdering No. Q t y. 100804 20 200901 20 200101 50 200102 50 Dimensions (mm) Width/Length/Hight, G32 13/53.6/59.5 13/53.6/59.5 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 MF 150 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 MF 150 Connection capacity Dimensions (mm) Width/Length/Hight, G32 13/53.6/51.1 13/53.6/51.1 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 MF 150 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 MF 150 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material * Other voltages available upon request F U S E T E R M I NA L B L O C K S IEC 60947-7-1 rated data 35 RFT5 RFT5 -N L RFT5-LD width 8 mm width 8 mm width 8 mm Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 36 Fuse terminal block, without indicator, for mounting on G 32 , TH 35- 7.5, 15 for fuse cartridge 5*20 and 5*25mm Fuse terminal block, with neon lamp, for mounting on G 32 , TH 35- 7.5, 15 for fuse cartridge 5*20 and 5*25mm End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Marking Type RFT5 RFT5 RFT5-NL 800/8 3/III/I 6.3 6 3/III/I 6.3 6 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 100805 Type 20 20 RFT5-NL 110-250VAC EB32 8 1 2 3 EB/1 9.5 NS8 200101 50 200102 50 For details see Accessories IEC 60947-7-1 rated data EB32 8 EB/1 9.5 NS8 100807 20 200101 50 200102 50 Fuse terminal block, with LED, for mounting on G 32 , TH 35- 7.5, 15 for fuse cartridge 5*20 and 5*25mm End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Marking Width/Length Hight, G32/TH 35-7.5/TH 35-15 Hight, G32/TH 35-7.5/TH 35-15 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Type 1 2 3 O rdering No. Q t y. RFT5-LD 12-24VDC 24-48VAC 100806 20 EB32 8 200101 50 200102 50 EB/1 9.5 NS8 For details see Accessories 8/72.5 59.4/55.6/63.1 Connection capacity 8/72.5 8/72.5 59.4/55.6/63.1 59.4/55.6/63.1 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5 1.2 PA 6.6 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5 1.2 PA 6.6 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) 3/III/I 6.3 6 Dimensions (mm) For details see Accessories Dimensions (mm) Width/Length R FT 5 -LD Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material * Other voltages available upon request 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5 1.2 PA 6.6 F U S E T E R M I NA L B L O C K S IEC 60947-7-1 rated data 37 TERMINAL BLOCKS C O L O U R E D Raad Manufacturing Company initiated manufacturing RTP series in two colour varieties, gray and blue, and has, honorably, succeed to turn the series in eleven colours in order to meet its customer’s demands and provide them other opportunities to handle through 11-coloured terminal blocks as the followings: Grey Blue Light cream Black Brown Red Orange Yellow Green Violet White R T P T E R M I NAL B L O CK S TERMINAL BLOCKS S E R I E S R T M Melamine moulded products are specialized to resist any deformation effect and enjoy a very high tracking resistance .This resin has excellent non-hygroscopic behavior with low humidity absorption, compared to PA 6.6., having a higher continuous service temperature. Raad melamine terminals are technically produced and best for working sites which level of dryness and humidity is in variable conditions. One disadvantage of melamine terminal blocks in comparison to the PA 6.6 type is their low flexibility and their lack of disposable feature. Raad melamine terminal blocks in RCT and RTM series are G32 mounting rails mountable designed. 40 RTM2.5 RTM4 RTM6 R T M 10 width 6.2 mm width 6.6 mm width 8 mm width 10 mm M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) 42 Description Type Terminal block, for mounting on G 32 End Plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection RTM2.5 max. current (A) Test socket Marking EP-RTM2.5 3 EB32 8 1 2 3 R TM2.5 R TM4 500/6 3/III/I 24 2.5 500/6 3/III/I 32 4 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 100201 100 200501 100 200101 50 Type RTM4 EP-RTM4,6,10 3 EB32 8 100202 50 200502 100 200101 50 50 50 EB/1 200102 EB/1 200102 9.5 9.5 CCM10-2.5 10-pos. 200520 10 CCM10-4 10-pos. 200522 10 200521 50 CCM4-4 4-pos. 200523 50 CCM4-2.5 4-pos. 16 16 TS3/6/2.3 200540 50 TS3/6/2.3 200540 50 NS6 NS6.4 For details see Accessories For details see Accessories Dimensions (mm) Width/Length/Hight, G32 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Type Terminal block, for mounting on G 32 End Plate width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection max. current (A) Test socket Marking RTM6 EP-RTM4,6,10 3 EB32 8 1 2 3 R TM6 R TM10 500/6 3/III/I 41 6 500/6 3/III/I 57 10 O rdering No. Q t y. 100203 50 200502 100 200101 50 Type RTM10 EP-RTM4,6,10 3 EB32 8 O rdering No. Q t y. 100204 50 200502 100 200101 50 50 50 EB/1 200102 EB/1 200102 9.5 9.5 CCM10-6 10-pos. 200524 10 CCM10-10 10-pos. 200526 10 200525 50 CCM4-10 4-pos. 200527 50 CCM4-6 4-pos. 24 30 TS3/8/4 200541 50 TS3/8/4 200541 50 NS6.4 NS6.4 For details see Accessories For details see Accessories Dimensions (mm) 6.2/36.2/46.2 6.6/39.8/51.5 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC 60947-7-1 rated data Width/Length/Hight, G32 8/39.8/51.5 8/39.8/51.5 0.5-10 0.5-10 0.5-6 20-8 A5 12 M3.5 1.2 MF 150 0.5-16 0.5-16 0.5-10 20-6 B6 12 M4 1.5 MF 150 Connection capacity 0.5-4 0.5-4 0.5-2.5 20-12 A3 10 M2.5 0.4 MF 150 0.5-4 0.5-4 0.5-4 20-12 A4 12 M3 0.5 MF 150 Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material R T M SERIES IEC 60947-7-1 rated data 43 RTM16 RTM25 RTM35 RTM5 0 width 13 mm width 14 mm width 17.5 mm width 20 mm IEC 60947-7-1 rated data RTM16 R TM25 1000/8 3/III/I 76 16 1000/8 3/III/I 101 25 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) Description Type Terminal block, for mounting on G 32 End Plate width (mm) RTM16 EP-RTM16,25 3 EB/1 9.5 EB/2 10 End bracket, for G 32 TH 35- 7.5, 15 100205 50 200503 50 200102 50 200103 50 Type RTM25 EP-RTM16,25 3 EB/1 9.5 EB/2 10 100206 50 200503 50 200102 50 200103 50 Cross-connection 1 2 3 47 TS3.5/8/4 NS8 200528 200542 10 CCM10-25 10-pos. 200529 10 50 65 TS4/8/4 NS8 200543 50 For details see Accessories For details see Accessories Dimensions (mm) Width/Length/Hight, G32 IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material RTM35 EP-RTM35 3 EB/1 9.5 EB/2 10 End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended 1000/8 3/III/I 150 50 O rdering No. Q t y. Type O rdering No. Q t y. 100207 20 RTM50 100208 20 200504 20 EP-RTM50 3 200506 20 200102 50 200103 50 EB/2 10 200103 50 max. current (A) Test socket Marking 1 2 3 CCM10-35 10-pos. 200530 10 CCM3-50 3-pos. 200531 10 65 180 TS4/8/4 200543 50 NS8 NS8 For details see Accessories For details see Accessories Dimensions (mm) 13/46.4/61.2 13/46.4/61.2 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) Terminal block, for mounting on G 32 End Plate width (mm) R TM50 1000/8 3/III/I 125 35 Cross-connection CCM10-16 10-pos. max. current (A) Test socket Marking Type R TM35 Width/Length/Hight, G32 17.5/54/67.1 20/68/77.1 1.5-16 1.5-35 1.5-35 14-1 B9 14.9 M6 3.5 MF 150 6-16 6-50 10-50 8-0 B10 19 M8 4.5 MF 150 Connection capacity 0.5-16 0.5-16 0.5-16 20-4 B7 12.3 M5 2.5 MF 150 0.5-16 0.5-25 0.5-25 20-3 B7 12.3 M5 2.5 MF 150 Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material R T M SERIES M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 width (mm) Raad recommended 44 O rdering No. Q t y. IEC 60947-7-1 rated data 45 40 42 R T P T E R M I NAL B L O CK S S E R I E S TERMINAL BLOCKS R C T RCT4 RCT6 RCT16 RC T3 5 width 7 mm width 8 mm width 10.2 mm width 16.5 mm Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Description 48 Terminal block, for mounting on G 32 End Plate width (mm) Partition width (mm) End bracket, for G 32 width (mm) End bracket, for G 32 TH 35- 7.5, 15 width (mm) Cross-connection max. current (A) Type RCT4 EP-RCT4 3 P-RCT4 3 EB32 8 CCT10-4 10-pos. CCT4-4 4-pos. 16 RCT4 RCT6 250/4 3/III/I 24 2.5 320/4 3/III/I 41 4 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description O rdering No. Q t y. 100101 100 200201 100 200210 100 200101 50 200220 200221 10 50 Type RCT6 EP-RCT6 3 P-RCT6 3 EB32 8 EB/1 9.5 CCT10-6 10-pos. CCT4-6 4-pos. 16 IEC 60947-7-1 rated data 100102 50 200202 100 200211 100 200101 50 200102 50 200222 200223 10 50 Terminal block, for mounting on G 32 End Plate width (mm) Partition width (mm) End bracket, for G 32 width (mm) Raad recommended End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended Cross-connection Dimensions (mm) Width/Length/Hight, G32 max. current (A) 7/28/41 8/34.8/48 1-4 1-4 1-2.5 16-12 A3 8 M3 0.5 MF 150 1.5-6 1.5-6 1.5-4 14-10 A4 10 M4 1.2 MF 150 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material RCT16 R TM35 320/4 3/III/I 57 10 500/6 3/III/I 125 25 Type O rdering No. Q t y. RCT16 Type O rdering No. Q t y. 100103 50 RCT35 100104 20 200203 100 EP-RCT35 3 200204 20 200212 100 EB32 8 200101 50 EB/1 9.5 200102 50 EB/1 9.5 200102 50 EB/2 10 200103 50 EP-RCT16 3 P-RCT16 3 CCT10-16 10-pos. CCT4-16 4-pos. 24 200224 200225 10 50 Dimensions (mm) Width/Length/Hight, G32 10.2/36.8/50 16.5/49.8/62.7 2.5-16 2.5-16 2.5-10 12-6 B6 12 M4 1.2 MF 150 6-16 6-35 10-25 8-2 B8 16 M6 2.5 MF 150 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material R CT SERIES IEC 60947-7-1 rated data 49 R C T50 RCT70 RCT95 width 22.5 mm width 54 mm width 54 mm RCT50 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) Description Terminal block, for mounting on G 32 End Plate width (mm) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 End bracket, for G 32 TH 35- 7.5, 15 width (mm) Raad recommended 50 Type Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description RCT50 100105 20 EP-RCT50 3 200205 20 EB/2 200103 22.5/59.5/70.7 Connection capacity Solid (mm2) Multi stranded (mm2) Flexible (mm2) American Wire Gauge (AWG) IEC test gauge Stripping Iength (mm) Clamping screw Tightening torque (N.m) Insulation material Terminal block, for mounting on G 32 End bracket, for G 32 TH 35- 7.5, 15 width (mm)Raad recommended Type RCT70 R CT95 1000/8 3/III/I 192 70 1000/8 3/III/I 232 95 O rdering No. Q t y. Type O rdering No. Q t y. RCT70 100106 5 RCT95 100107 5 EB/2 10 200103 50 EB/2 10 200103 50 50 Dimensions (mm) 10 Dimensions (mm) Width/Length/Hight, G32 IEC 60947-7-1 rated data 800/6 3/III/I 150 35 10-16 10-50 16-35 6-1 B9 18 M8 3.5 MF 150 Width/Length/Hight, G32 54/80/57 54/91/57 Connection capacity Cable lugs DIN 46235 Clamping screw Tightening torque (N.m) Insulation material 16-70 M8 6 MF 150 16-95 M10 10 MF 150 R CT SERIES IEC 60947-7-1 rated data 51 RCT120 RCT150 RCT185 RCT240 width 54 mm width 54 mm width 54 mm width 54 mm Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) RCT120 R CT150 1000/8 3/III/I 269 120 1000/8 3/III/I 309 150 Voltage (V) / Impulse voltage (kV) Pollution degree/Voltage category/Material group Current (A) Cross - section (mm2) O rdering No. Q t y. Description Type Terminal block, for mounting on G 32 End bracket, for G 32 TH 35- 7.5, 15 width (mm)Raad recommended RCT185 100111 5 RCT240 100110 5 EB/2 10 200103 50 EB/2 10 200103 50 Description Type O rdering No. Q t y. Type Terminal block, for mounting on G 32 End bracket, for G 32 TH 35- 7.5, 15 width (mm)Raad recommended RCT120 100108 5 RCT150 100109 EB/2 10 200103 50 EB/2 10 200103 M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Dimensions (mm) 52 IEC 60947-7-1 rated data 5 50 RCT185 R CT240 1000/8 3/III/I 353 185 1000/8 3/III/I 415 240 O rdering No. Q t y. Type O rdering No. Q t y. Dimensions (mm) Width/Length/Hight, G32 54/91/57 54/107/57 Connection capacity Cable lugs DIN 46235 Clamping screw Tightening torque (N.m) Insulation material 16-120 M10 10 MF 150 25-150 M12 14 MF 150 Width/Length/Hight, G32 Connection capacity Cable lugs DIN 46235 Clamping screw Tightening torque (N.m) Insulation material 54/122/57 54/122/57 50-185 M16 25 MF 150 50-240 M16 25 MF 150 R CT SERIES IEC 60947-7-1 rated data 53 End Plates and Partitions Cross-Connections Test Accessories Mouting Rails and End Brackets R T P T E R M I NAL B L O CK S A C C E S S O R I E S Marking 40 L B/1 Marking Marker carrier for groups of terminal blocks M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 This type of labeling meets the advantage of easy handling. The NS sheets consist of white polyamide with black printings. The sheets are labeled horizontally with maximum 3 characters, easy to read and high-contrast.The hot impressed black printings are absolutely wiping resistant. One NS sheet consists of 5 strips, includes 10 single tags that can be simply pushed into the label slots of the terminal blocks. The NS sheets can be divided at any point and can be manually labeled with ease. 56 Size The push-on tags of NS marking system can be requested in any of the following sizes with or without printed characters. 1) NS6, used for terminal block width 6 mm or more. 2) NS6.4, used for terminal block width 6.4 mm or more. 3) NS 8, used for terminal block width 8 mm or more. Packing The NS sheets are delivered in plastic bags of 10 sheets=50 strips=500 single tags. NS6.4 Terminal width >6.4 Description Group marker carrier, for mounting on G32 TH 35- 7.5, 15 width (mm) Group marker carrier, for mounting on G32 TH 35- 7.5, 15 width (mm) Type (111...) (222...) (333...) (444...) NS Special printings Special printings can be offered on request. NS8 Terminal width >8 (555...) (666...) (777...) (888...) Type O rdering No. Q t y. Material LB/1 19.5 200104 50 PA6.6 LB/2 9.5 200105 50 PA6.6 Size Ord. No. Qty. NS6 202001 10 NS6.4 203001 10 NS8 204001 10 NS6 202005 10 NS6.4 203005 10 NS8 204005 NS6 202009 NS6.4 203009 10 NS8 204009 NS6 202013 NS6.4 203013 10 NS8 204013 10 Type (999...) Size Ord. No. Qty. NS6 202033 10 NS6.4 203033 10 NS8 204033 10 NS6 202037 10 NS6.4 203037 10 10 NS8 204037 10 10 NS6 202035 10 NS6.4 203034 10 10 NS8 204034 10 10 NS6 202041 10 Accessories The NS Quick Marking System NS6 Terminal width >6 L B/2 NS6.4 203041 10 57 NS8 204053 10 NS6 202017 10 NS6.4 203017 10 NS8 204017 NS6 202021 NS6.4 203021 10 NS8 204021 NS6 202025 NS6.4 203025 10 NS8 204025 10 (1010...) (0...9) (1...10) NS6 202042 10 NS6.4 203042 10 10 NS8 204042 10 10 NS6 202077 10 NS6.4 203045 10 10 NS8 204077 10 10 NS6 202043 10 NS6.4 203043 10 NS8 204043 10 NS6 202029 10 NS6.4 203029 10 NS8 204029 10 (11...15) (11...20) (16...20) (21...25) NS6 202047 10 NS6.4 203047 10 NS8 204047 10 (51...100) (26...30) (1...50) (101...150) (31...35) (10...500) (36...40) M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 (41...45) 58 (46...50) (51...55) (56...60) (61...65) (21...30) (66...70) (71...75) (76...80) Size Ord. No. Qty. NS6 202049 10 NS6.4 203109 10 NS8 204049 10 NS6 202051 10 NS6.4 203051 10 NS8 204051 10 NS6 202053 10 NS6.4 203053 10 NS8 204041 NS6 202057 NS6.4 203141 10 NS8 204141 10 Type (31...40) (81...50) Size Ord. No. Qty. NS6 202085 10 NS6.4 203085 10 NS8 204085 10 NS6 202086 10 NS6.4 203086 10 NS8 204086 10 NS6 202087 10 NS6.4 203087 10 10 NS8 204087 10 NS6 202088 NS6.4 203088 10 NS8 204088 10 NS6 202059 10 NS6.4 203159 10 NS8 204059 NS6 202073 NS6.4 203173 10 NS8 204073 NS6 202074 NS6.4 203074 10 NS8 204074 10 (86...90) (91...95) 10 NS8 204090 NS6 202129 NS6.4 203111 10 NS8 204142 10 NS8 204076 NS6 202078 NS6.4 203078 10 NS8 204078 10 NS6.4 203118 10 NS8 204108 10 NS8 204165 10 NS6 202094 NS6.4 203063 10 NS8 204063 10 202079 10 203079 10 NS8 204079 NS6 202080 NS6.4 203080 10 NS8 204080 10 NS6 202081 10 NS6.4 203083 10 NS8 204083 10 203121 10 NS8 204121 10 NS6 202084 10 NS6.4 203138 10 10 NS8 204138 10 10 NS6 202159 10 NS6.4 203139 10 NS8 204169 10 10 203182 10 10 NS8 204182 10 10 NS6 202097 10 NS6.4 203097 10 59 NS8 204097 10 NS6 202093 10 NS6.4 203073 10 NS8 204093 10 203069 10 NS8 204069 10 NS6 202000 10 203117 10 204107 10 NS8 204157 NS6 202149 NS6.4 203054 10 NS8 204149 10 NS6 202153 10 NS6.4 203000 10 NS8 204000 10 NS6 202123 10 NS6.4 203133 10 10 NS8 204115 10 NS6 202045 NS6.4 203113 10 NS8 204113 10 NS6 202189 10 NS6.4 203055 10 NS8 204153 10 (UVW...) (RSTN...) (R...) (2W...) 202182 NS6.4 NS8 (1W...) NS6 202069 NS6.4 (UVW...MP) NS6.4 204145 10 10 10 NS6 10 10 10 202148 NS8 10 204084 204116 NS6 10 10 203084 NS8 10 10 203056 NS8 10 10 202157 NS6.4 10 10 NS6 (61...70) 10 203016 203129 UNPRINTED (BB...) 202096 202065 (UVWN...) (3V...) NS6 NS6 (AB...Z) (2V...) NS6.4 NS6.4 NS6.4 (51...60) 10 NS6.4 10 202083 10 204136 202121 202107 204082 203136 NS8 204161 NS6 NS6 NS6.4 NS6 10 NS8 10 NS8 204016 (71...80) 10 202136 10 NS8 10 204187 NS6 10 10 10 NS8 10 10 203116 203082 10 203058 NS6.4 202082 10 NS6.4 202116 NS6 203187 202161 204064 NS6.4 NS6.4 204159 NS6 10 10 NS6 NS8 10 10 202187 NS8 10 204081 204183 NS6 10 10 203081 NS8 10 10 10 NS8 10 10 10 NS6.4 10 10 203064 (351...400) 10 203183 203119 202104 (301...350) 202183 202119 NS6 (1V...) NS6 NS6 (LPE...) (L...) NS6.4 NS6.4 NS6.4 (141...150) 10 202108 10 NS6 10 204130 (81...90) 10 204135 NS6 10 204188 203135 NS8 203059 NS8 NS8 10 NS6.4 10 NS6.4 10 202099 10 203188 10 10 204134 202188 10 203110 NS6 NS6 NS6.4 202145 NS6.4 NS8 10 204185 202110 10 10 204186 NS6 204060 10 203186 NS8 NS8 NS6 (451...500) NS6.4 10 NS8 10 10 10 10 10 202186 10 10 203124 NS6 10 10 (401...450) Qty. 203185 10 (100...150) (Y...) Ord. No. 202185 203060 (101...110) (N...) Size NS6 202120 202134 NS6.4 (121...130) Type NS6.4 NS6 NS6 (131...140) (111...120) NS6.4 NS6.4 (91...100) 10 10 10 10 204114 204062 10 203076 NS8 203062 10 NS6.4 10 NS8 23090 202076 10 203114 NS6.4 NS6.4 204075 202114 202092 202090 NS6 NS6 NS6.4 204061 204089 NS8 10 NS6 NS6 (51...66) 10 204035 NS8 NS8 10 203115 NS8 10 10 10 NS6.4 10 10 203075 10 10 10 202075 202115 10 10 NS6 NS6 203061 203057 NS6.4 Qty. 202091 202089 (151...200) (201...250) Ord. No. NS6 NS6 (96...100) (251...300) Size NS6.4 NS6.4 (41...50) Type Accessories Type (3W...) (---...) (+++...) NS6 202130 10 NS6.4 203130 10 10 NS8 204030 10 10 NS6 202141 10 NS6.4 203131 10 NS8 204131 10 NS6 202184 10 NS6.4 203184 10 NS8 204184 10 NS6.4 203189 10 NS8 204139 10 (1U...) (2U...) (3U...) End Plate The last terminal in a row must, in most cases, be covered with an end plate. Within one terminal strip, composed of various terminal sizes, end plates should also be interposed. The end plate external dimensions correspond to the core dimensions of the attendant terminal. The end plates are held by an end bracket. Partition Depending upon the operating voltage, a partition must be fitted next to cross-connection groups, so that the necessary clearance and creepage distance can be maintained. Small Partition M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Space-saving partitions can be post-fitted between crossconnections for terminal blocks. 60 General Partition These types of partitions serve for RTP16-50. Cover Several safety regulations, namely as the accident prevention regulation, require that the live elements of electrical operating components must be protected against direct contact. This type is provided only for RTP 50 terminal series. Type Ord. No. Application Material Qty. P-RCT4 200210 RCT4 MF150 100 P-RCT6 200211 RCT6 MF150 100 P-RCT16 200212 RCT16 MF150 100 P-RTP2.5 201005 RTP2.5 PA6.6 100 P-RTP4. 6, 10 201008 RTP4. 6, 10 PA6.6 50 SP-RTP2.5-10 201007 RTP2.5-10 PA6.6 100 SP-16-35 201101 RTP16-35 PA6.6 50 SP-50 201102 RTP50 PA6.6 50 GP 201103 - PA6.6 20 EP-RCT4 200201 RCT4 MF150 100 EP-RCT6 200202 RCT6 MF150 100 EP-RCT16 200203 RCT16 MF150 100 EP-RCT35 200204 RCT35 MF150 20 EP-RCT50 200205 RCT50 MF150 20 EP-STC6 200403 STC6 PA6.6 100 EP-RDT4 200404 RDT4 PA6.6 100 CP-50 201180 RTP50 PA6.6 50 EP-RTM2.5 200501 RTM2.5 MF150 100 EP-RTM4, 6, 10 200502 RTM4, 6, 10 MF150 100 EP-RTM16,25 200503 RTM16,25 MF150 50 EP-RTM35 200504 RTM35 MF150 20 EP-RTM50 200506 RTM50 MF150 20 EP-L2, LU2 200710 RCTL2,RCTLU2 PA6.6 50 EP-RCTF10 200901 RCTF10 MF150 20 EP-RTP2.5 201001 RTP2.5 PA6.6 100 EP-RTP4, 6, 10 201003 RTP4, 6, 10 PA6.6 50 Accessories End Plates and Partitions 61 Max Ord. T y p e Current (A) No. Application Qty. T y p e CC10-2.5 For cross-connection bar, connection sleeves and screws are already captively mounted with the corresponding number of poles. The cross-connection then only requires inserting in the individual terminal row when fitting. The cross-connection unit is supplied in 2, 3 and 10 poles. CC3-2.5 CC2-2.5 M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 62 To handle cross-connection of several terminal blocks, with the same potential, copper cross-connection bars are used. These cross-connection bars supplied in 2, 3 and 10 pole lengths are equal to the individual terminal widths. The cross-connection bar is electrically joined through a connection sleeve to the terminal block bus bar. Connection Sleeve and Screw The length of the brass connection sleeve is matched to the individual terminal. In order to be able to connect the cross-connection bar and the connection sleeve to a terminal block bus bar, a brass screw is applied. The cross-connections are designed so that where a terminal does not need any cross-connection; it is possible to remove the screw and its sleeve, thus no cross-connection occurs in the terminal. 201021 RTP2.5 201022 10 CCM10-2.5 50 CCM4-2.5 50 CCM10-4 BC10-4 12 CC10-4 DRTP4, STC6 201023 32 CC2-4 CC10-D4 CC3-D4 201014 32 201024 10 CCM4-4 10 CCM10-6 50 CCM4-6 201025 50 CCM10-10 201310 10 CCM4-10 201311 50 RTP4 DRTP4 200530 RTM35 10 201121 10 CCM3-50 180 200531 RTM50 10 20 CCT10-4 50 RTP16 CC2-16 201122 20 CCT4-4 CC10-25 201123 10 CCT10-6 20 CCT4-6 CC3-25 65 201124 RTP25 CC2-25 201125 20 CCT10-16 CC10-35 201126 10 CCT4-16 CC3-35 65 CC2-35 CC3-50 CC2-50 201127 RTP35 201128 180 201129 201130 10 50 63 50 201120 47 50 65 10 CC3-16 10 CCM10-35 50 CC10-16 200527 RTM10 50 10 201029 RTP10 200526 10 RTM25 201028 201031 200525 RTM6 50 200529 CC2-6 201030 30 200524 10 RTM4 65 50 CC10-10 47 24 200523 50 CCM10-25 10 CC2-10 200522 10 10 201026 CC3-10 RTM2.5 RTM16 CC10-6 RTP6, RST6, RTT6 200521 Qty. 200528 50 201027 200520 Application 47 201312 47 Ord. No. CCM10-16 CC2-D4 CC3-6 16 20 RTP4, RDTU4 CC3-4 Cross-Connection Bar 201020 20 Max Current (A) Accessories Cross-Connection 20 20 RTP50 10 10 200220 16 20 24 200221 200222 200223 200224 200225 RCT4 RCT6 RCT16 10 50 10 50 25 35 35 6.3 D 1.5 D d 18 15 TH 35-7.5 TH 35-15 L L 1 M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 M Test socket 25 1.5 6.3 a) 32 b) L1 M 9 M This type of test accessory, made of brass, is tightened in the middle of terminal block busbar. Type Drawing Ord No. L L1 d D M Application TS3/6/2.3 TS3/8/4 TS3.5/8/4 TS4/8/4 TS3/14/4 TSS3/26/4 a a a a a b 200540 200541 200542 200543 200703 200705 6 8 8 8 14 26 3.5 3.5 5 5 5 9 2.3 4 4 4 4 4 4 6 7 7 6 5.7 3 3 3.5 4 3 3 RTP2.5,4 RTP6,10,RTM6,10,RCTF10 RTP16,RTM16 RTP25,35,RTM25,35 RCTL2,RCTLU2 RCTL2,RCTLU2 QTY. 50 50 50 50 50 50 Moveable link Moveable link, which is half in plastic (PA 6.6) and half in brass, permits the current branching for the terminal block, functioning as a cross-connection, which makes a connection, and though installed can also disconnect. It is also used in test disconnect terminal blocks. Type Ord No. Application QTY. ML2A ML4A ML2B ML4B ML2N ML3N ML4N 200706 200707 200701 200702 200708 200709 200712 RCTL2,RCTLU2 RCTL2,RCTLU2 RCTL2,RCTLU2 RCTL2,RCTLU2 RST6,RTT6 RST6,RTT6 RST6,RTT6 100 50 100 50 50 50 50 18 18 G 32 G32/S G32 IEC 60715 mounting rails form the basis for the mounting of modular terminal blocks, as well as for rail mountable electro technical and electric components. Active and passive components are installed on mounting rails. In control cabinet design, the TH 3515, TH 35-7.5 and G32 rails stand out with their high degree of dimensional accuracy and surface tempering. All steel versions are electroplated and additionally passivised with a yellow chromate coating; comply with the IEC 60715 standard. Raad supplies components w h i c h a r e t o t a l l y c o - o r d i n a t e d i n t h e i r f u n c t i o n a l i t y. The mounting rails can also be used as a protective busbar. Raad protective conductor terminals meet the r eq uir em ent s sp ecif ied in IEC 60947-7-2. The rails are both produced in slotted and unslotted f or m f or easier ap p licat ion b y t he user s. Description Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m, Slotted Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m, Unslotted Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m, Slotted Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m, Unslotted Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m , Slotted Mounting Rail In accordance with IEC 60715, yellow chromated, length 2m, Unslotted Material Type Ord No. QTY. TH 35-7.5/S 401102 20 TH 35-7.5 401104 20 TH 35-15/S 401106 20 TH 35-15 401108 20 G 32/S 401002 20 G 32 401004 20 Steel, galvanized &yellow chromated Accessories 7.5 64 TH35-15/S TH35-15 TH35-7.5/S TH35-7.5 Mounting Rails and End Brackets Test Accessories 65 1.8 18 1.8 ARS mounting rail supports allow for sloped attachment of mounting rails at an angle of 35∞.Their designs are available with M6 threads. The FRS mounting rail supports are similar to ARS rail supports, but with flat surface. 84 M6 84 M6 18 48 35 20 Description Type Ord No. QTY. M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Angled rail support 401202 10 allow for sloped attachment of mounting rail at ARS/M6 an angle of 35, with M6 thread Flat rail support 401204 10 allow for flat attachment of mounting rail, with FRS/M6 M6 thread Material Steel, galvanized &yellow chromated 66 End Brackets Description End bracket For mounting on G32, adjustable with terminal NS marking Width(mm) End bracket For mounting on G32 and TH35, adjustable with terminal NS marking Width(mm) End bracket For mounting on G32 and TH35, adjustable with terminal NS marking Width(mm) Material Type Ord No. QTY. EB32 8 200101 50 EB/1 9.5 200102 50 EB/2 10 200103 50 Polyamide 6.6 G e n e r a l Te c h n i c a l Information Mounting Rails Accessories UL R RAAD products use parts and materials conform to standards in electrical industry and are subject to quality control system. Confidence in Connection Metals 68 Insulating Material RAAD terminal blocks use two kinds of insulating materials, thermoplastics and thermosetting plastics. Thermoplastics are processed using economical and environmentally healthy injection molding processes, and have good recycling properties and can be reused. Polyamide 6.6 is a thermoplastic, used in the insulation body of RAAD products. This modern semi-crystalline material has excellent electrical, mechanical, chemical and other characteristics even at 100 C for continues operating. The short-time peak temperatures are permissible up to about 200 C and the melting point is around 260 C. Polyamide 6.6 absorbs moisture from its surroundings, on average 2.8 %. This makes the PA 6.6 more flexible and resistant to breakage, even at -40 C. Today PA 6.6 is approved for use by the approval authorities such as CSA, NEMKO, KEMA, PTB, SEV, UL, VDE, etc. Thermosetting materials have high dimensional stability, negligible water absorption and are tropic and termite resistant. Thermosetting plastic used by RAAD is a melamine formaldehyde molding compound type MF 150, mainly organically filled and is specified and tested in accordance with ISO, DIN, ASTM, JIS and BS. MF 150 has high continuous operating temperature, excellent inflammability and very good tracking resistance. Properties Standard Max. application temperature IEC60216-1 Flammability class UL94 Comprative tracking index IEC60112 Electrical strength (1 mm thickness) Surface resistivety Volume resistivety Tropical and termite resistance IEC60243-1 IEC60093 IEC60093 - Unit 0C,<50h PA 6.6 125 0C, <20.000h 105 V2 600 CTI CTIM 575(475) kV/mm 31 Ω >1015 cm 1015 good - MF 150 160 135 V0 600 600 30 1011 1012 good GENERAL TECHNICAL INFORMATION Achieving a uniform quality on production in mass productuion is impossible unless through establishment of quality management system. Having the certificate of quality management system in accordance with ISO 9000-2000 issued by authorized and well-known standard institutions, Raad manufacturing company is seeking to assure its customers for the existence of such system. Furthermore, Raad products quality is proven by outstanding institutions, being well-known in electric field all around the world, offered various types of certificates. Both, the certificates of products quality and quality management system indicate reliable products, manufactured by the company. The development plan to gain other certificates on products quality and quality management system is still alive and continuing. Material M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Raad, Quality in Action All metal parts in RAAD products are electro-plated using the latest state of engineering. The surface protection conforms to technical standards. Steel parts at the beginning are zinc-plated and then a yellow chromate layer coats over the zinc, providing the best possible passivation. Copper and brass parts are tin-plated. Tin plating provides excellent protection against corrosion and has good electrical conduction. 69 Following are some of the important standards and regulations taken into consideration during the development and the production of our products, insofar as they apply. M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 This is the most popular of all known methods of connection. No other connection method allows such high contact forces to be produced in such a small space as a screw. RAAD terminal block screw connection is easy to operate with a standard screwdriver, suitable for all types of conductors without special preparation, absolutely gas tight and vibrationproof. 70 Reliable clamping Most RAAD products use a clamping unit system which has been proven millions of times, world-wide. The clamping units as well as clamping screws are produced from hardened steel. When the clamping screw is tightened, the resultant force causes the upper thread overlap to spring open, thus causing a locking action to be exerted on the screw and an excellent resistance against vibration is achieved. IEC 60947-7-2 (2002) Low - voltage switchgear and controlgear Part 7: Ancillary equipment Section 2: Protective conductor terminal blocks for copper conductors IEC 60947-7-3 (2002) Low-voltage switchgear and controlgear Part 7: Ancillary equipment Section 3: Safety equipment for fuse terminal blocks IEC 60947-1 (2004) Low - voltage switchgear and controlgear Patr 1: General rules IEC 60998-2-1 (2002) Connecting devices for low voltage circuits for household and similar purposes Part 2-1: Particular requirements for connecting devices as separate entities with screw - type clamping units IEC 60998-1 (2002) Connecting devices for low voltage circuits for household and similar purposes Part 1: General requirements IEC 60664-1 (2002) Insulation coordination for equipment within low voltage systems Part 1: Principles, requirements and tests IEC 60715 (1981) Dimensions of low - voltage switchgear and controlgear standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installations IEC 60127-1 (2003) Miniature fuses Part 1: Difinitions of miniature fuses and general requirements for miniature fuse - links IEC 60127-2 (2003) Miniature fuses Part 2: Cartridge fuse - links GENERAL TECHNICAL INFORMATION Screw Connection Standards and Regulations IEC 60947-7-1 (2002) Low- voltage switchgear and controlgrear Part 7: Ancillary equipment Section 1: Terminal blocks for copper conductors 71 IEC 60112 (2003) Methods for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions. IEC 60243-1 (1988) Methods of test for electric strength of solid insulating materials Part 1: Tests at power frequencies IEC 60093 (1980) Methods of testing of electrical insulating materials specific contact resistance and specific surface resistance of solid, electrically insulating materials M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 IEC 60216-1 (2001) Electrical insulating materials Properties of thermal endurance Part 1: Ageing procedures and evaluation of test results 72 IEC 60695-2-10 (2000) Fire Hazard testing Part 2-10: Glowing/hot-wire based test methods GLow-wire apparatus and common test procedure IEC 60695-2-11 (2000) Fire Hazard testing Part 2-11: Glowing/hot-wire based test methods GLow-wire apparatus and common test procedure UL 94 (1991) Test for flammability of plastic materials for parts in devices and appliances IEC 60079-0 (2004) Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 60079-7 (2001) Electrical apparatus for explosive gas atmospheres Part 7: Increased safety ‘e’ IEC 60079-11 (1999) Electrical apparatus for explosive gas atmospheres Part 7: Intrinsic safety ‘i’ UL 1059 (2001) Standard for Terminal Blocks CSA CC 22.2 No.158 (1999) Terminal Blocks Mechanical strength of terminals IEC 60947-7-1 is the main standard which meets all types of Raad terminal blocks. All Raad products are designed, manufactured and tested in accordance with the standard, which along with IEC 60947-1 determines the tests to be conducted on terminal blocks, each as a type test. Testsí details are specified in the standards. Below is an abstract of the forgoing tests. To handle this test on screw-clamp terminal blocks, the conductors must be used, which have the maximum crosssection. The conductors must be connected and disconnected five times depending on the screw clamping, as determined in table 4 of IEC 60947-1. Where a screw is loosened, a new conductor must be applied. During the test, clamping units shall not work loose and there shall be no damage that will impair the further use of the screwed connections. Attachment of the terminal block to its mounting rail To assure the stability of the terminal block to its mounting rail, with standard shape and dimension values, a relevant test is conducted by inserting a 150 mm long steel pin with a diameter specified in table 3 of IEC 60947-7-1. It is connected to each clamping unit and a tightening torque must be applied, as given in table 4 of IEC 60947-1. Force must be applied to the pin with regular intensity and without tears; the corresponding value must be taken from table 3 of IEC 60947-7-1. The distance between the application point of the force and the centre of clamping unit must be equal to 100 mm. During the test, no terminal block must disengage from its mounting rail or suffer any damage. Table 3 IEC 60947-7-1 Attachment test parameters Rated cross-section of terminal block mm 2 AWG/kcmil 0.2 0.34 0.5 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 24 22 20 18 16 14 12 10 8 6 4 2 0 00 000 0000 250 kcmil 300 kcmil 350 kcmil 500 kcmil 300 600 kcmil Force N Diameter of pin mm 1 1.0 5 2.8 10 5.7 15 12.8 20 20.5 Table 4 IEC 60947-1 Tightening torques for the verification of the mechanical strength of screw-type terminals Diameter of thread mm Metric standard values 1.6 2.0 2.5 3.0 3.5 4.0 4.5 5 6 8 10 12 14 16 20 24 Column I Tightening torque Range of diameter ≤1.6 >1.6 >2.0 >2.8 >3.0 >3.2 >3.6 >4.1 >4.7 >5.3 >6.0 >8.0 >10 >12 >15 >20 >24 up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including up to and including 2.0 2.8 3.0 3.2 3.6 4.1 4.7 5.3 6.0 8.0 10.0 12 15 20 24 I II III 0.05 0.1 0.2 0.25 0.3 0.4 0.7 0.8 0.8 1.2 2.5 - 0.1 0.2 0.4 0.5 0.6 0.8 1.2 1.8 2.0 2.5 3.5 4.0 - 0.1 0.2 0.4 0.5 0.6 0.8 1.2 1.8 2.0 3.0 6.0 10.0 14.0 19.0 25.0 36.0 50.0 Applies to screws without heads which, when tightened, do not protrude from the hole, and to other screws which cannot be tightened by means of a screwdriver with a blade wider than the root diameter of screw. Column II Applies to nuts and screws which are tightened by means of a screwdriver. Column III Applies to nuts and screws which can be tightened by means other than a screwdriver. Damage and accidental loosening of conductors-flexion test Specifically, this test is applied on terminal blocks suited for the connection of unprepared round copper conductors. It is a must to test both rigid and flexible conductors with Min and Max cross-sections; optionally, connections of multiple conductors to a single clamping unit. A particular test apparatus is considered to aid the test performance. During the test, neither must the conductor slip out of the clamping unit, nor does breakage occur near the clamping unit. Soon after the flexion test, GENERAL TECHNICAL INFORMATION IEC 60529 (2001) Classification of degrees of protection provided by enclosures (IP code) Terminal blocks tests 73 Pull-out test After the flexion test was conducted, a pull-out is carriedout by force, the value of which is presented in table 5 of IEC 60947-1 to the conductor attached to the clamping unit; this force must be applied regularly and without tears, for 1 minute; for screw-clamp terminal blocks, the tightening screws must not be newly tightened. During the test, neither must the conductor slip out of the clamping unit, nor does breakage occur near the clamping unit. Table 5 IEC 60947-1 Test values for flexion and pull-out tests for round copper conductors M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 C onductor Diameter Height cross-section of bushing H 1) hole 1) 2) 74 Mass Pulling force mm 2 AWG/kcmil mm mm kg n 24 22 20 18 16 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 600 6.5 6.5 6.5 6.5 6.5 6.5 9.5 9.5 9.5 9.5 13.0 13.0 14.5 14.5 15.9 15.9 19.1 19.1 19.1 22.2 22.2 25.4 25.4 28.6 28.6 260 260 260 260 260 260 280 280 280 280 300 300 320 320 343 343 368 368 368 406 406 432 432 464 464 0.2 0.2 0.3 0.4 0.4 0.4 0.7 0.9 1.4 2.0 2.9 4.5 5.9 6.8 8.6 9.5 10.4 14 14 14 15 16.8 16.8 20 22.7 10 15 20 30 35 40 50 60 80 90 100 135 156 190 236 236 285 351 427 427 427 503 503 578 578 0.2 0.34 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 kcmil kcmil kcmil kcmil kcmil kcmil 1) Tolerances: for heigh H ± 15 mm, for diameter of the bushing hole ± 2 mm. 2) If the bushing hole diameter is not large enough to accommodate the conductor without binding, a bushing having the next larger hole size may be used. Rated cross-section Rated connection capacity It is the value of max connectable conductor crosssection. The rated cross-section shall be selected from the standard cross-sections presented in table 1, IEC 60947-1. Where a ferrule is applied on a flexible conductor, then a terminal block of one step higher rated cross-section must be used, for example, a 2.5mm≤ flexible conductor covered with the relating ferrule must be inserted to a one step higher cross-section, i.e. terminal block with rated cross-section 4mm. It is the range of cross-sections and the number of connectable conductors based on which the terminal blocks are designed. The IEC 947-7-1 determines the relation between the rated cross-section and rating connecting capacity of terminal blocks. Practically, terminal blocks up to 35mm2, must be possible to connect a conductor of cross-section equal to the nominal crosssection and lower up to two cross-sections. Rated connection capacity It is the value of max connectable conductor crosssection. The rated cross-section shall be selected from the standard cross-sections presented in table 1, IEC 60947-1. Where a ferrule is applied on a flexible conductor, then a terminal block of one step higher rated cross-section must be used, for example, a 2.5mm≤ flexible conductor covered with the relating ferrule must be inserted to a one step higher cross-section, i.e. terminal block with rated cross-section 4mm. Table 1 IEC 60947-7-1 Standard cross-sections of round copper conductors and approximate relationship between mm2 and AWG/kcmil sizes Rated cross-section AWG/kcmil size mm 2 0,2 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 NOTE: 24 22 20 18 16 14 12 10 8 6 4 2 1 0 00 000 0000 250 kcmil 300l kcmil 350l kcmil 400 kcmil 500 kcmil 600 kcmil Equivalent metric arra mm 2 0,205 0,324 0,519 0,82 1,3 2,1 3,3 5,3 8,4 13,3 21,2 33,6 42,4 53,5 67,4 85,0 107,2 127 152 177 203 253 304 The dash, when it appears, counts as a size when considering connecting capacity (see 7.1.7.2). Insulation coordination for equipment within low voltage systems IEC 60664-1 deals with insulation coordination for equipment within low voltage systems. It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon the performance criteria. Terminal blocks standard, IEC 60947-7-1, has the rules for coordination of insulation in accordance with IEC 60664-1. Clearances Degrees of pollution in the micro-environment Pollution degree 1 No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. Pollution degree 2 Only non- conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be expected. Pollution degree 3 Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to be expected. Pollution degree 4 The pollution generates persistent conductivity caused by conductive dust, rain or snow. Overvoltage categories Equipment of overvoltage category I is equipment for connection to circuits in which measures are taken to limit transient overvoltages to an appropriately low level. Examples for such devices are protected electronic circuits. Equipment of overvoltage category II is energyconsuming equipment to be supplied from the fixed installation. Examples of such equipment are appliances, portable tools and other household and similar loads. Equipment of over voltage category III is equipment in fixed installations and for cases where the reliability and the availability of the equipment are subject to special requirements. Examples of such equipment are switches in fixed installation and equipment for industrial use with permanent connection to the fixed installation. Equipment of overvoltage category IV is for use at the origin of the installation. Examples of such equipment are electricity meters and primary over-current protection equipment Table 1 IEC 60664-1 Rated impulse voltage for equipment energized directly form the low-voltage mains Nominal voltage of the Voltage line to 1) supply system based neutral derived Rated impulse voltage V 2) on IEC 38 from normal V voltages a.c. or Over voltage category d.c. up to and Three phase Single including I II III IV phase V 120-240 230/400 277/480 4009690 1000 50 100 150 300 600 1000 230 500 800 1500 2500 4000 500 800 1500 2500 4000 6000 800 1500 1500 2500 2500 4000 4000 6000 6000 8000 8000 12000 1) Equipment with these rated impulse voltages can be used in installation in accordance with IEC364-4-443. 2) The / mark indicates a four-wire three-phase distribution system. The lower value is the voltage line -to- netural, while the higher value is the voltage line-to-line. Where only one value is indicated, it refers to three-wire, three-phase systems and specifies value line-to-line. Table 13 Rated impulse withstand voltage Uimp kV IEC 60947-1 Minimum clearance inair Minimum clearances mm Case A Case B Inhomogeneeous field Homogeneeous field conditions ideal conditions (see 2.5.63) (see 2.5.62) Pollution degree 1 2 3 4 0.33 0.5 0.8 1.5 2.5 4.0 6.0 8.0 12 0.01 0.04 0.1 0.5 1.5 3 5.5 8 14 0.2 0.8 0.5 1.5 3 5.5 8 14 1.6 1.5 3 5.5 8 14 3 5.5 8 14 Pollution degree 1 2 3 4 0.01 0.04 0.1 0.3 0.6 1.2 2 3 4.5 75 0.2 0.3 0.6 1.2 2 3 4.5 GENERAL TECHNICAL INFORMATION a pull-out test must occur without restoring the initial tightening torque. 0.8 1.6 1.2 2 3 4.5 2 3 4.5 NOTE The values of minimum clearance in air are based on 1,2/50 µs impulse voltage, for barometric pressure of 80 kPa, equipment to normal atmospheric pressure at 2 000 m above sea level. Creepage distances Material groups Dielectric test Temperature-rise test The creepage distance is based on the rated voltage which is derived from the working voltage or nominal voltage of the supply system. The minimum creepage distances are allocated to the rated voltage according to the pollution degree and material group in table 15, IEC 60947-1. In this catalog the products must be measured in compliance with IEC 60664-1 for overvoltage category III, pollution degree 3 and material group I, other wise the product information would include additional details. According to the range of values of the comparative tracing index (CTI), material groups are classified as follows: Material Group 600 ≤ CTI Material Group II 400 ≤ CTI <600 Material Group IIIa 175 ≤ CTI<400 Material Group IIIb 100 ≤ CTI<175 The test is conducted on 5 adjacent terminal blocks, mounted on a metallic mounting rail and connected with rated cross-section conductors. Test voltage must have a sinusoidal waveform with a frequency between 45 and 62 Hz. The values applied, for 5 seconds, are those specified in the table 12A, IEC 60947-1. Irrespective of glow discharges without drop of voltage, no disruptive discharges shall occur during the test. The current in a terminal block causes overheating due to continuous operation. The overheating level shall not overcome a specified value, thus a temperature-rise test is applied to verify this performance requirement. The test is conducted by means of temperature-rise test on 5 neighboring terminal blocks connected at a test current as specified in table 4, IEC 60947-7-1. The temperaturerise of any part of the centrally located terminal block shall not exceed 45 K. Table 12A Table 4 M O D U L AR T E R M I NA L B L O C K S / 2 0 0 5 Rated insulation voltage of equipment or working voltage a.c. r.m.s or d.c. 4) 76 IEC 60947-1 Dielectric test voltage corresponding to the rated insulation voltage IEC 60947-1 Minimum creepage distances Pollution degree 1 5) 2 5) Creepage distances for equipment subject to long term stress mm Pollution degree Pollution degree Pollution degree 1 Material group 2 V 1) 2) 1) I 10 12.5 16 20 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000 6 300 8 000 10 000 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.04 0.063 0.1 0.16 0.25 0.4 0.56 0.75 1 1.3 1.8 2.4 3.2 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.063 0.1 0.16 0.25 0.4 0.63 1 1.6 2 2.5 3.2 4 5 0.08 0.09 0.1 0.11 0.125 0.14 0.16 0.18 0.2 0.22 0.25 0.28 0.32 0.42 0.56 0.75 1 1.3 1.8 2.4 3.2 4.2 5.6 7.5 10 12.5 16 20 25 32 40 0.4 0.42 0.45 0.48 0.5 0.53 0.56 0.6 0.63 0.67 0.71 0.75 0.8 1 1.25 1.6 2 2.5 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 3 Material group II 0.4 0.42 0.45 0.48 0.5 0.53 0.8 0.85 0.9 0.95 1 1.05 1.1 1.4 1.8 2.2 2.8 3.6 4.5 5.6 7.1 9 11 14 18 22 28 36 45 56 71 IIIa IIIIb 0.4 0.42 0.45 0.48 0.5 0.53 1.1 1.2 1.25 1.3 1.4 1.5 1.6 2 2.5 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 1) Material groups I, II, IIIa, IIIb. 2) Material groups I, II, IIIa. 3) Values of creepage distances in this area have not been established. Material groups IIIb is in general not recommended for application in pollution degree 3 above 630 V and in pollution degree 4. 4) As an exception, for rated insulation voltages 127 V, 208 V, 415/440 V, 660/690 V and 830 V, creepage distances corresponding to the lower values 125 V, 200 V, 400 V, 630 V and 800 V respectively may be used. 5) The values given in these two columns apply to creepage distances of printing I 1 1.05 1.1 1.2 1.25 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.5 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 125 1 1.05 1.1 1.2 1.25 1.3 1.6 1.7 1.8 1.9 2 2.1 2.2 2.8 3.6 4.5 5.6 7.1 9 11 14 18 22 28 36 45 56 71 90 110 140 V 4 Material group II Rated insulation voltage Ui IIIa IIIIb 1 1.05 1.1 1.2 1.25 1.3 1.8 1.9 2 2.1 2.2 2.4 2.5 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 125 160 3) I 1.6 1.6 1.6 1.6 1.7 1.8 1.9 2 2.1 2.2 2.4 2.5 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 125 160 200 Material group II IIIa 1.6 1.6 1.6 1.6 1.7 1.8 2.4 2.5 2.6 2.8 3 3.2 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 125 160 200 250 1.6 1.6 1.6 1.6 1.7 1.8 3 3.2 3.4 3.6 3.8 4 5 6.3 8 10 12.5 16 20 25 32 40 50 63 80 100 125 160 200 250 320 IIIIb Ui ≤ 60 60 < Ui ≤ 300 300 < Ui ≤ 690 690 < Ui ≤ 800 800 < Ui ≤ 1 000 1 000 < Ui ≤ 1 5001) AC test voltage (r.m.s.) DC test voltage2), 3) V V 1 000 1 500 1 890 2 000 2 200 - 1 415 2 120 2 670 2 830 3 110 3 820 1) For d.c. only. Test voltages based on 4.1.2.3.1, third paragraph of IEC 60664-1. 3) A direct current test voltage may be used only if an alternating test voltage cannot be applied. See also 3) b) ii) of 8.3.3.4.1. 2) Short-time withstand current The standard IEC 947-7-1 obliges terminal blocks to withstand a current equal to 120A per each square mm of rated cross-section for 1 second. Voltage drop 3) circuit materials. 6) The values of creepage distances stated for 250 V can be used for 230 V (±10 %) normal voltage. NOTE 1 It is appreciated that tracking or erosion will not occur on insulation subjected to working voltages of 32 V and below. However, the possibility of electrolytic corrosion has to be considered and for this reason minimum creepage distances have been specified. NOTE 2 Voltage values are selected in accordance with the R10 series. Voltage drop at the terminal indicates an index of contact resistance against the follow of current. The voltage drop test is conducted before and after mechanical strength, short-time withstand current and temperature-rise tests. IEC 60947-7-1 states that the voltage drop, measured on a new terminal block, must be lower than 3.2 mV and after the tests lower than 150 % of the value measured before the tests. IEC 60947-7-1 Values of test current for temperature-rise test, ageing test and voltage drop test for metric wire sizes Rated cross-section Test Rated cross-section Test current current mm 2 A mm 2 A 0.2 0.5 0.75 1 1.5 2.5 4 6 10 16 4 6 9 13.5 17.5 24 32 41 57 76 25 35 50 70 95 120 150 185 240 300 101 125 150 192 232 269 309 353 415 520 GENERAL TECHNICAL INFORMATION Table 15 The CTI values refer to values obtained in accordance with IEC 60112, method A, for the insulating material used. 77 North 3rd floor, 28, 2nd St. Shahnazari St., Madar Sq. Mirdamad Blv. Tehran - Iran Tel. +98 21 227 8455 - 6 Fax +98 21 227 8457 salse@raad-co.com www.raad-co.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Create Date : 2005:12:03 14:17:19+03:30 Creator : Adobe Acrobat 7.0 Modify Date : 2005:12:03 14:18:34+03:30 Producer : Advanced PDF Compressor 2012 / WinSoftMagic Inc. XMP Toolkit : 3.1-701 Metadata Date : 2005:12:03 14:18:34+03:30 Format : application/pdf Document ID : uuid:345729f3-7e5e-4d32-9f44-e7b1c96d946a Instance ID : uuid:898ba0e9-73d2-4d9f-93cc-7c3ae4dcc1c6 Page Count : 41EXIF Metadata provided by EXIF.tools