PDF Rohde&Schwarz EK895 HF Reciever Datasheet

Rohde&Schwarz_EK895 HF reciever_Datasheet Rohde&Schwarz_EK895 HF reciever_Datasheet

Rohde%26Schwarz_EK895 HF reciever_Datasheet The Eye | File Listing

User Manual: PDF T E X T F I L E S

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadPDF Rohde&Schwarz EK895 HF Reciever Datasheet
Open PDF In BrowserView PDF
Version
04.00

Digital VLF-HF Receivers R&S® EK895/R&S® EK896
For all shortwave applications from 10 kHz to 30 MHz
◆ Compact DSP-based receivers for the
following applications:
– Radiomonitoring and radio
detection
– Radiocommunications
– Search operation, DF systems
– Frontend for HF intelligence tasks

◆ Digital signal processing (DSP) for
convenient and versatile operation
◆ Two models:
– Half-rack receiver R&S EK895
– Search receiver R&S EK896
◆ Realtime remote control or
master-slave mode

◆ Tried and tested system concept
◆ Excellent price/performance ratio
◆ Extremely reliable operation under
harsh environmental and EMC
conditions

June
2003

VLF-HF Receiver R&S EK895
with control panel

Digital VLF-HF Receivers R&S® EK895/R&S® EK896
Special features
◆ Excellent large-signal behaviour, very
good intercept points
◆ High resolution of tuning frequency
down to 1 Hz
◆ Fast and low-noise synthesizer
◆ Demodulators for AM, CW, LSB, USB,
ISB, FM, FSK, AFSK and FAX included
in basic configuration
◆ 13 bandwidths from 150 Hz to 8 kHz
(quasi-continuous on request)
◆ RF preamplifier, switchable (noise
figure 8kT0)
◆ Double notch filter
◆ Noise blanker
◆ DATA LINK reception (option)
◆ Passband tuning
◆ Syllabic squelch
◆ Special RTTY (FSK/AFSK) mark and
space filters, matched to the selected
shift

2

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

◆ Digital data output
◆ Maximum input voltage protection up
to 100 V EMF
◆ Control interface fully complying with
international standards
◆ Low power consumption <25 VA
(basic model R&S EK895), therefore
little self-heating
◆ Powerful microprocessor for bus interfacing, menus and user programs
◆ Dual receiver as 19“ desktop or rack
models
◆ Free slots for retrofitting of options
◆ Integrated self-test down to module
level with plain-text result display
◆ Available with operator front panel or
remote-control-only front panel
◆ Highly compact; width 1/219"
(R&S EK895) or 19" (R&S EK896)

Operational features
◆ Easy to operate via terminal,
computer or front panel
◆ High rejection of strong interfering
signals
◆ 1000 programmable channel memory
locations
◆ Scan mode for programmable
frequency ranges and any desired
channel sequences
◆ Remote control of all settings – over
any distance when using modems
◆ Ideal handoff receivers in stationary,
mobile and remote receiving systems
◆ High availability owing to long MTBF
and short MTTR
◆ Easy to adapt to special requirements
by means of optional plug-in modules
and standardized interfaces

Overview
General characteristics of the
R&S EK895
With the R&S EK890 family, Rohde&
Schwarz is presenting a powerful generation of VLF-HF receivers which are topend products benefiting from many years
of experience in this field. All members of
this family are based on the R&S EK890
basic model. Due to the advantages of
digital signal processing, embedded in
the improved receiver versions R&S
EK895/R&SEK 896 a number of additional features and operational convenience have been added. Straightforward, menu-guided selection and programming of the receiving settings
ensure excellent processing and handling
of the received signal content. The compact design is due to the use of largescale-integration SMDs. Featuring full
system compatibility, the receivers provide the basis for extremely economical
customer-specific solutions.
With its excellent RF characteristics and
clearcut, full remote-control capability via
standardized data interfaces, the R&S
EK890 family is suitable for all civil,
administrative and military shortwave

applications. These receivers are an ideal
choice for receiving systems that have to
fulfill extremely high reliability requirements, in particular under harsh environmental and EMC conditions.
Operation is possible via an ASCII terminal, a computer (PC) or via the front panel.
Using line drivers, a master receiver can
control up to 99 remote receivers in master-slave operation. On the R&S EK895/
R&S EK896, two wired and bus-integrated
slots for plug-in modules are provided for
extensions, e.g. BCD interface or input filters.
Uses
The comprehensive sequence control can
be used for all demanding shortwave
reception tasks. Due to flexible programming of the processor, the following operating modes are possible:
◆ Manual operation
◆ Remote control or master-slave
operation
◆ Channel scanning, sequential and
programmable
◆ Frequency scan
◆ Channel reception
◆ Password-protected channel
reception

The R&S EK890 family thus fulfills the
requirements for versatile use in voice
receiving and any kind of data communication system as well as for all radiomonitoring, radio detection and radio
intelligence (COMINT) applications. For
application in DF systems, an R&S EK895
is used as the master (controlling synthesizer), its LOs being brought out for external amplification, distribution and phaselocked application to all other receivers.
The built-in memory has capacity for nonvolatile storage of 1000 complete channel
settings so that channel management
and control by an external computer are
not required but are nevertheless additionally possible. Due to their excellent
characteristics regarding dynamic range,
low synthesizer noise and gain control
range, the receivers are ideal high-performance frontends for subsequent signal
processing.

Two independent Receivers R&S EK895 with remote-control panel in a 19“ rackmount adapter

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

3

Search Receiver R&S EK896

Design

The R&S EK896 has especially been
designed for complex tasks of radio
detection and search reception, its operating principle and configuration perfectly matching the relevant requirements. Basically it is fitted with panel
controls and LCD displays for local and
remote-control operation.

RF unit
The antenna signal is routed via a lowpass filter, which is provided for rejecting
image frequencies and suppressing oscillator reradiation, and applied to the input
mixer where it is converted to the first IF
of 41.44 MHz by means of an oscillator
variable in 1 Hz steps. The crystal filter
that follows determines the maximum
receiving bandwidth of 10 kHz and rejects
the second image frequency. A fixed frequency of 40 MHz is used for conversion
to the second IF of 1.44 MHz.

High-speed and reliable radiomonitoring
is supported by temporary storage of a
complete receiver setup and its transfer
to or readout from the connected slave.
The R&S EK896 is the optimal operator’s
position in modern radiomonitoring systems. In the usual master-slave mode, a
master receiver can control up to 99 slave
receivers via additional line drivers to
handle simultaneous radiomonitoring or
specific radio detection tasks. Due to its
outstanding characteristics, the R&S
EK896 is ideal for use as a standalone
receiver. All R&S EK895 options can be
fitted.

The high-performance mixer at the
receiver input ensures excellent largesignal behaviour. The intercept points are
typically +70 dBm (IP2) and +35 dBm
(IP3); the crossmodulation transfer is 10%
for an interfering signal of +21 dBm. In
most cases, additional filters such as suboctave filters are therefore not required.

Search Receiver R&S EK896 with front panel for local/remote control

4

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

IF/AF processor (DSP)
The second IF is converted to the third IF
of 25 kHz using a 5.66 MHz fixed frequency. After digitization of the third IF in
a 16-bit A/D converter, the processor
assumes all signal generation and processing tasks (DSP) including the following:
◆ Automatic, remote or manual control
(AGC, DGC, MGC)
◆ Measurement of received levels
◆ Filtering with 13 fixed or quasi-continuously adjustable bandwidths
◆ Demodulation, passband tuning,
double notch filter
◆ Noise blanker, syllabic squelch
◆ Generation of BFO frequency as
analog IF from 0 to 40 kHz, digital IF
as serial data and I/Q data stream
Synthesizer
The synthesizer supplies all the conversion frequencies required for the RF and
the IF demodulator units. Due to direct
digital frequency synthesis, the first conversion oscillator can be varied in 1 Hz
steps. The settling time of the oscillator is
5 ms for any frequency variation. Two
phase-locked loops (PLLs) produce the
40 MHz and 5.66 MHz fixed frequencies.
The operation of the total of four PLLs in
the synthesizer is continuously monitored.
In the basic version, all the frequencies
are derived from a temperature-compensated crystal oscillator. Higher accuracy
requirements can be fulfilled by including
a heated crystal oscillator (optional
OCXO) or using an external frequency
standard (1 MHz, 5 MHz or 10 MHz).

Control functions
Processor and software
The 16-bit microprocessor using powersaving CMOS technology is what makes
the high-performance, compact, reliable
and user-friendly concept of the R&S
EK895 possible. The microprocessor is
not only responsible for setting and managing the module functions, it also communicates with the outside world via the
panel controls and the data interface,
executes the internal programs and
ensures the high operational reliability
through various routines:
◆ Nonvolatile storage of all settings
◆ Continuous testing of CPU, RAM and
PROM functions
◆ Continuous monitoring (CM) of
synthesizer
◆ BIT (built-in test) for module testing
The simple and logical ASCII command
syntax for controlling the receiver via the
serial interface includes control commands for the following:

Basic settings
◆ Frequency
◆ BFO
◆ Bandwidth
◆ Demodulation modes
◆ Gain control mode
◆ Digital threshold
◆ Passband tuning

Channel operations
◆ Channel manipulations
◆ Store channel
◆ Erase channel
◆ Select channel
◆ Readout channel
Special operations
◆ Master-slave operation
◆ Complete erasure of channel memory

Search operations
◆ Frequency scanning
◆ Channel scanning
◆ Hold time
◆ Dwell time
◆ Stop criterion

In addition, the following functions can
be selected on the front panel:
◆
◆
◆
◆
◆
◆
◆

Test operations
◆ Read CM status
◆ BIT start
◆ BIT readout

Display of interface configuration
Fast channel storage
Channel buffer storage
Default settings on/off
Password for channel service
Local/remote mode
Knob increments

System operations
Readout of
◆ Software version
◆ Options
◆ Error messages
◆ Signal level
◆ Deviation

Block diagram of the Digital VLF-HF Receivers R&S EK895/R&S EK896
Antenna

IF/AF processor

RF unit

Option
A
DSP

D

IF
converter
455 kHz

IF 0 to 40 kHz
or
IF 455 kHz
Digital IF (data,
clock, frame)

D

1

Synthesizer

A

IF = 25 kHz

IF = 1.44 MHz

IF = 41.44 MHz

D

4

A

41.45 MHz to 71.44 MHz
External
frequency
standard

TTY

5.66 MHz

AF 1
I/Q

TCXO
OCXO (option)
Headphones

Output

AF 2

40 MHz

RS-232-C/RS-485
Option 1

Control unit

EMC
filter

Option 2

RS-232-C/
RS-485
interface

AC supply

Processor

Power
supply

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

5

Various configurations
Receivers with control panel
In the standard version, the R&S EK895
receiver is available with an operator
front panel, which can also be retrofitted.
This front panel also permits manual control and display of all functions while full
remote-control capability is maintained.
This version is particularly suitable for use
as a master receiver in receiving systems
or as a standalone unit (standard with
R&S EK896).
The operator interface allows for a combination of hardkey and softkey entries.
Parameters that are frequently handled,
i.e. receive frequency, channel, BFO frequency and passband tuning (PBT), can
be entered directly via a separate keypad.
All current receiver settings are continuously displayed in large high-contrast
characters on a backlit LCD. An additional
bargraph indicator allows display of
either the receive level (0 to 120 dBµV, in
5 dB steps), the DGC or MGC settings or
the frequency offset (as a tuning aid and
deviation indication).
Receivers with remote-control panel
Optionally, the receivers are remotecontrolled by ASCII command sequences
via a multistandard interface (RS-232-C,
RS-485, RS-422/423, 2-/4-wire). In the
simplest case, a terminal can be used as
the control unit. For more convenience, a
computer can be used to handle complex
tasks and to create special user interfaces. A demo program for generating a
virtual front panel is available if desired.
The features newly incorporated into the
R&S EK895/R&SEK 896, such as preamplifier (PREAMP), noise blanker (NB),
squelch (SQ), notch filter (NOTCH) and
passband tuning (PBT), are selected in
submenus using softkeys. If one of these
features is active, a bargraph appears on
the display above the relevant inscription
(PREAMP, NB, SQ, NOTCH, PBT).

6

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

Remote Control Unit R&S GB899
(model 03)
This option is an R&S EK895 reduced to
control functions plus a Control Panel
R&S GB890. It is used for realtime remote
control of handoff receiving equipment,
over long distances preferably via additional modems.
IF bandwidth configuration
The R&S EK895/R&S EK896 features 13
bandwidths from 150 Hz to 8 kHz. Quasicontinuous tuning in 128 steps is available as an option.
Input Filter Unit R&S FK890H1
(option)
The input filter module comprises a lowpass filter, a bandpass filter and eight
suboctave filters which are automatically
selected with the receive frequency.
BCD Interface R&S GC890 (option)
A plug-in BCD interface is available for
controlling frequency-dependent add-on
units with parallel interfaces, e.g. a selective antenna.
TTY Line Current Source R&S GH890
(option)
For the operation of older teletype units
that require line current (single/double
current), a TTY line current source requiring no extra slot can be accommodated.

Rear view of the
R&S EK895

IF Converter R&S UX895 (option)
The IF Converter R&S UX895 can be supplied as a submodule for incorporation
into the IF/AF processor. Instead of the
analog IF output signal of 0 to 40 kHz, it
linearly converts the set receive parameters to the IF of 455 kHz.
Digital Selection R&S FK896D
(option for R&S EK896 only)
This option considerably improves the
input selectivity of the receiver. Two versions are available for 20 dB or 40 dB
stopband attenuation. The automatically
tracking selection circuit includes the following functions:
◆ 7-circuit lowpass (0 to 30 MHz)
◆ 5-circuit lowpass (0 to 1.5 MHz) for
rejection of strong shortwave interfering signals
◆ Tracking single-circuit filter (1.5 MHz
to 30 MHz) with a stopband attenuation of >20 dB (40 dB) at 10% spacing
from the center frequency
◆ Switch on/off by remote control
◆ Input voltage protection of ≥200 V EMF
The Digital Selection R&S FK896D is recommended for use in environments with
strong RF interference (collocation problems). It improves input selection by automatically tracking the receive frequency
and, at the same time, considerably
increases input-voltage protection
(overload protection).

Operating concept

Main menu: MOD GAIN BW SCA MORE
Second menu level

↓
MOD

Demodulation modes
MORE: for further modes

AM CW LSB USB MORE

GAIN

Control modes
Auto, manual, auto+manual, auto+digital
MORE: fast or slow control

AGC MGC A+M A+D MORE

BW

Bandwidth

BW ↓ BW ↑

SCA

Scan mode
Frequency sweep, channel sweep (any sequence),
channel sweep (incremental), stop or continue
sweep, program sweep

FRQ CHP CHS S/C PRO

The R&S EK890 family has a suitable operating mode for every application (see also
page 8). The remote-control interface is
configured to the RS-485 standard and is
bus-compatible for system operation.
Users who want to control their radiomonitoring system from the receiver front
panel rather than from a computer can use
the receivers of the R&S EK890 family as a
master receiver or install the Remote
Control Unit R&S GB899.

MORE: M/S SYS SPEC CHM MEM

↓
M/S

Master-slave operation
ADR62 GET PUT
Address slave (indicate slave address, e.g. 62), read
out or vary slave settings

SYS

System status
Read out firmware version, built-in options, error
messages; start self-test; MORE: total reset

VERS OPT CM BIT MORE

SPEC

Special functions
Rotary knob: step size on/off;
level setting for threshold-controlled external
switching signal; show serial interface setting;
switch to remote control; default settings on/off

KNOB LEV SER REM DEF

CHM

Channel memory parameters
Channel memory indication and channel-specific
parameter variation without interrupting reception

MOD GAIN BW THLD

Setting
of R&S EK895
down to second menu levelCLA CLCH STCH STO
Channel memory
operations
MEM possibilities
Clear all memory, clear certain memory,
store to certain memory, use next free memory

Broadband IF Output R&S GM893
(option)
The optional broadband output (plug-in
module) supplies a 1 MHz output signal at
the first IF of 41.44 MHz (relative to a
receive frequency of ±500 kHz). To prevent impairment of the receiver sensitivity of the main channel (message channel), the path to the broadband channel is
decoupled by approx. 10 dB. For broadband spectrum analysis, a spectrum
display can be connected to this broadband output.
Digital data output (option)
For further digital signal processing of the
received signal, a separate digital IF interface (connector X 69 at rear) is available,

delivering the digital DATA, CLOCK
FRAME outputs (0 to 40 kHz, sampling
rate 100 ksps).
DATA LINK option
If DATA LINK operation (MIL-STD-188203-1A) is required, special receiver versions are available.

The softkey-menu operator interface provides the ergonomical advantage of clean
front panel layout as well as access to a
large number of setting parameters. When
you insert extension modules, they are
automatically detected and incorporated
in the software BIT and the menu system.
The clearcut operating concept of the R&S
EK890 family has five menu levels which
allow 50 logically structured operating routines to be called up by softkeys. In spite of
the multitude of functions, operation is
higly convenient, e.g. each type of modulation is assigned a default setting with all
relevant parameters, which can also be
individually programmed.
The table to the left shows all possible settings down to the second menu level.
For fast access to the setting parameters,
the R&S EK896 has 12 additional hardkeys, e.g. for standard types of modulation, bandwidth variation, etc.

1.44 MHz IF output, unregulated
(option)
For connecting and operating an external
IF spectrum display, e.g. the Digital
Spectrum Display R&S EP090, an
unregulated IF output at 1.44 MHz is
available. This option uses the HF unit
(model 03) and has to be ordered along
with the basic receiver.

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

7

Control concepts of the Digital VLF-HF Receivers R&S EK895/R&S EK896

Remote control

Local control

… via PC or ASCII
terminal

RS-485 bus

RS-485 bus

R&S EK895 with control
panel as a standalone unit
or as a master receiver in
systems

R&S EK895 with front
panel for remote control

Search Receiver R&S EK896

… via the Remote Control
Unit R&S GB899,
model 03

Master-slave operation

Slave receivers, max. 99 addressable

8

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

Specifications
Frequency range

10 kHz to 30 MHz

Resolution

1 Hz

Frequency drift
–10 to +45°C aging/year
Frequency standard
5 x 10 –7
1 x 10–6
Oven-controlled frequency standard 1 x 10–7
1 x 10–7
External frequency standard

1/5/10 MHz, 0.2 V to 1 V rms

Antenna input

BNC connector, 50 Ω

VSWR

<1.5 typ. with preamp on for f >250 kHz
<3 typ. w/o preamp for f >5MHz
otherwise <4 typ.

Max. input voltage (≤30 MHz)
Oscillator reradiation into 50 Ω
termination
Demodulation modes

IF bandwidth
(standard values)

≤10 µV
CW/MCW (A1A, A1B, A2A, A2B)
FAX1 (F1C)
AM/AME (A3E, H2A, H2B, H2E) USB/
LSB (R2A, R3E, J2A, J3E) ISB (B8E)
FSK/AFSK (F1A, F1B), F6 (F7B)
FAX2 (F3C), FM (F3E)
DATA LINK acc. to
MIL-STD-188-203-1A (on request)
3 dB
±75 Hz
±150 Hz
±300 Hz
±500 Hz
±750 Hz
±1050 Hz
±1200 Hz
±1350 Hz
±1550 Hz
±2000 Hz
±2400 Hz
±3000 Hz
±4000 Hz

60 dB
±150 Hz
±225 Hz
±430 Hz
±770 Hz
±990 Hz
±1600 Hz
±1760 Hz
±1900 Hz
±2100 Hz
±3400 Hz
±3700 Hz
±4200 Hz
±5200 Hz

Inherent spurious signals (f >100 kHz) <−113 dBm (nominal −124 dBm)
Image frequency rejection

>90 dB

IF rejection

>90 dB

Weighted S/N ratio for 1 mV EMF

>46 dB SINAD

Gain control

automatic (AGC), manual (MGC) or
remote (DGC)

AGC error

≤3 dB typ. (1 µV to 1 V EMF)

Time response constants
Attack time
Decay time

<15 ms
25/150/500 ms, 1 s, 3 s

DGC range

0 to 120 dBµV EMF in 1 dB steps

BFO

−5.00 kHz to +5.00 kHz

Resolution

10 Hz

AFSK/FSK demodulator

transfer rate (50 baud to 600 baud)
and deviation range (±42.5 Hz to
±425 Hz) adjustable; V.28 interface
and audible tone circuit

Diplex telegraphy demodulator (F7B) 2 x V.28 interface
Channel memory

for 1000 channels, nonvolatile, storage of complete receiver setup for
each channel

Data interface

RS-232-C, RS-485 (bus-compatible)

Transfer rate

50 baud to 38400 baud

Outputs
AF output 1, AF (I)

0.3 kHz to 3.4 kHz; floating;
Zout =600 Ω
−10 dBm to +10 dBm

Settling range
128 steps, 100 Hz to 9 kHz

Sensitivity
For S/N=10 dB, f=0.1 MHz to 30 MHz
A1A (CW)
J3E (SSB), J7B
H3E (AME), 1 kHz, m=60%

0.4 µV EMF (−121 dBm), BW=300 Hz
1.0 µV EMF (−113 dBm), BW=2.7 kHz
2.7 µV EMF (−104 dBm), BW=6 kHz

480 mV rms, Zout ≈ 100 Ω
1.9 kHz ± 150 Hz in VLF range
(f<500 kHz) 1.9 kHz ±400 Hz in HF
range (f≥500 kHz)
1.9 kHz modulated
NBFM (3 dB bandwidth: ±4 kHz)

AF (Q)
FAX1 (F1C)

FAX2 (F3C)
FM (F3E)
AF output 2 (LSB in ISB mode)

0.2 µV EMF (−127 dBm), BW=300 Hz
0.4 µV EMF (−121 dBm), BW=2.7 kHz
1.0 µV EMF (−113 dBm), BW=6 kHz

Immunity to interference,
non-linarities
Intermodulation (1.5 MHz to 30 MHz;
∆f ≥30 kHz; interfering signal 0 dBm)
IP 2
IP3

Desensitization (interfering signal
300 mV EMF; ∆f ≥30 kHz; signal level
30 µV EMF; bandwidth 3.1 kHz)
≥20 dB SINAD

100 V EMF

Quasi-continuous bandwidth
(option for R&S EK895)

With preamplifier, f=0.2 MHz to
30 MHz
A1A (CW)
J3E (SSB), J7B
H3E (AME), 1 kHz, m=60%

Blocking (0.1 MHz to 30 MHz; interfering signal 6.3 V EMF (+23 dBm);
∆f ≥30 kHz; signal level 1 mV EMF
(−53 dBm); m=0.3; f=1 kHz)
≤1 dB signal attenuation

Settling range
Monitoring output

500 mV, Zout =332 Ω

FM video output

1 V/kHz, Zout =1 kΩ

IF (1.44 MHz) output (unregulated)

BW (–3 dB): ≥10 kHz;
gain: (18 ±2) dB, 50 Ω

IF output (analog)

0 to 40 kHz in 100 Hz steps,
0 dBm into 600 Ω or 455 kHz,
0 dBm into 50 Ω (optional)

IF output (digital)

serial data (clock, data, frame),
100 ksps

I/Q output (digital)

baseband signal, multiplexed,
5 V CMOS

>60 dBm (70 dBm typ.)
>30 dBm (35 dBm typ.)

Crossmodulation (0.1 MHz to 30 MHz,
interfering signal 5 V EMF (+21 dBm);
∆f ≥30 kHz; m=0.3; f=1 kHz; signal
level 10 mV EMF (−33 dBm))
≤10% modulation transfer

0.3 kHz to 3.4 kHz, floating,
Zout =600 Ω
−10 dBm to +10 dBm

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

9

Options
Control Panel R&S GB890
(model 03)

Remote Control Unit R&S GB899
(model 03, on request)

Broadband IF Output R&S GM893
(model 03)
with controls and indicators for complete receiver setup; connector for
loudspeaker or headphones
(max. 1 W into 8 Ω )
Control Panel R&S GB890 plus R&S
EK895 reduced to control functions,
using RS-232-C with a transfer rate of
50 baud to 19200 baud; modem operation is recommended for distances
beyond about 100 m

Input Filter Unit R&S FK890H1

lowpass filter 0 to 0.5 MHz
bandpass filter 0.5 MHz to 1.5 MHz
8 suboctave filters 1.5 MHz to 30 MHz

BCD Interface R&S GC890

frequency information, 22 bit parallel
(CMOS, 5 V)

TTY Line Current Source R&S GH890 single current: 40 mA/60 V
double current: ±20 mA/±30 V
IF Converter R&S UX895
(on request)

455 kHz, 0 dBm into 50 Ω,
BNC female

Digital Selection R&S FK896D
(R&S EK896 only)
Frequency range

0 to 30 MHz, at f <1.5 MHz as LPF

Stopband attenuation

≥20 dB (>40 dB: R&S FK896D, model
04) at 10% spacing from center frequency
(f = 1.5 MHz to 30 MHz)

Gain

0 to +2 dB

Tuning time

<10 ms

Inband IP3

≥34 dBm (≥30 dBm: R&S FK896D,
model 04)

Noise figure

13 dB typ.

RF input voltage protection
Response threshold

≥200 V EMF (Zin =50 Ω)
>10 V EMF or >4 A

10

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

Output frequency

41.44 MHz

3 dB bandwidth

>1 MHz

Attenuation

<10 dB relative to antenna input

Impedance

50 Ω

Oven-controlled frequency standard

aging/day ≤1 x 10 –9 (OCXO)

General data
Environmental conditions
Operating temperature range
Permissible temperature range
Storage temperature range
Humidity (non-condensing)

to MIL-STD-810 D
−10°C to +45°C
−25°C to +55°C
−40°C to +80 °C
max. 95 % at +40°C

Vibration test

10 to 55 Hz; 0.4 mm double amplitude

Shock test

30 g, 11 ms

EMC

to MIL-STD-461/462

MTBF

>14 000 h

Power supply

100/120/220/240 V −15/+10%,
47 Hz to 420 Hz (approx. 25 VA to
75 VA, depending on model)

Dimensions (W x H x D), weight
R&S EK895
R&S EK896

211 mm x 132 mm x 460 mm,
approx. 8 kg
426 mm x 132 mm x 460 mm,
approx. 11 kg

Ordering information
Digital VLF-HF Receiver

R&S EK895

Remote control via serial interface

6057.8996.02

With control panel; for local and remote control

6057.8996.12

With control panel; for local and remote control; with built-in OCXO

6057.8996.14

With control panel; for local and remote control; with built-in OCXO;
LINK11 reception

6057.8996.17

With control panel; for local and remote control; with built-in OCXO;
LINK11 reception; for use with external frequency standard

6057.8996.37

With control panel; for local and remote control; with 1.44 MHz IF output

6057.8996.63

Digital VLF-HF Search Receiver

R&S EK896

Control panel with speaker; for local and remote control

6038.2509.12

Control panel with speaker; for local and remote control; with built-in OCXO

6038.2509.14

With control panel; for local and remote control; with built-in OCXO;
LINK11 reception

6038.2509.17

With control panel; for local and remote control; with built-in OCXO;
LINK11 reception; for use with external frequency standard

6038.2509.37

Plug-in modules (R&S EK895, R&S EK896)
Preselection Unit

R&S FK890H1

6007.7750.02

Digitally Tuned RF Selection
Stopband attenuation 20 dB; for R&S EK896 only

R&S FK896D

6077.3019.02

Digitally Tuned RF Selection
Stopband attenuation 40 dB; for R&S EK896 only

R&S FK896D

6077.3019.04

BCD Interface

R&S GC890

6007.7809.02

Broadband IF Output

R&S GM893

6051.8494.03

Transfer Software Package

R&S EK890S3

6015.4492.02

Quasi-Continuous IF Bandwidth Control

R&S EK895S7

6077.0510.02

Loudspeaker Unit

R&S GA890L1

6041.6199.02

Remote Control Unit

R&S GB899

6037.3501.03

TTY Line Current Source

R&S GH890

6007.6054.02

Service Kit

R&S KA890C1

6030.9004.02

19" Assembling Kit for two R&S EK895
Desktop model

R&S KA890L1

6041.6699.02

19" Assembling Kit for two R&S EK895
For rack installation

R&S KA890L1

6041.6699.03

Recommended extras (R&S EK895, R&S EK896)

High-precision Oven-controlled Master Quartz Oscillator

6007.3255.03

IF Conversion to 455 kHz

R&S UX895

6077.0261.02

19" Adapter Kit
For one R&S EK895 and one blank panel

R&S ZZA-98

0827.4533.00

Digital VLF-HF Receivers R&S® EK895/R&S® EK896

11

P.O.B. 8014 69 ⋅ 81614 München, Germany ⋅ Telephone +49 89 4129-0 ⋅ Fax +49 89 4129-13663 ⋅ www.rohde-schwarz.com

PD 0758.0251.32 ⋅ Digital VLF-HF Receivers R&S® EK895/R&S® EK896 ⋅ Version 04.00 ⋅ June 2003 ⋅ Data without tolerance limits are not binding ⋅ Subject to change

R&S® is a registered trademark of Rohde&Schwarz GmbH&Co. KG · Trade names are trademarks of the owners

Rohde&Schwarz GmbH & Co. KG ⋅ Mühldorfstraße 15 ⋅ 81671 München ⋅ Germany
Printed in Germany

(Pe bb)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2003:07:02 14:30:23+02:00
Create Date                     : 2003:05:02 08:48:59Z
Creator                         : FrameMaker 7.0
Page Count                      : 12
Creation Date                   : 2003:05:02 08:48:59Z
Mod Date                        : 2003:07:02 14:30:23+02:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Metadata Date                   : 2003:07:02 14:30:23+02:00
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools

Navigation menu