Stretching the limits of impedance testing

1260
Impedance/gain-phase Analyzer

The 1260 Impedance/gain-phase
Analyzer is - without doubt - the most
powerful, accurate and flexible
Frequency Response Analyzer
available today.
In daily use by leading researchers
wherever measurement integrity and
experimental reliability are of
paramount importance, 1260’s solid
reputation is frequently endorsed in
published research papers in fields
such as:-

Noise free analysis

Impedance measurement

1260 uses Solartron Analytical’s
patented single-sine correlation
technique, which inherently removes
the noise and harmonic distortion
which plagues lesser instruments.

Virtually every liquid and solid is able
to pass current when a voltage is
applied to it. If a variable (ac) voltage
is applied to the material, the ratio of
voltage to current is known as the
impedance. The measured impedance
varies with the frequency of the
applied voltage in a way that is related
to the properties of the liquid or solid.
This may be due to the physical
structure of the material, to chemical
processes within it or a combination
of both.

• Frequency resolution: 1 in 65
million (0.015ppm)
• 0.1%, 0.1º accuracy - unsurpassed
by any similar instrument

• Corrosion studies

• Resolution to 0.001dB, 0.01º capturing every detail

• Battery research and fuel cells

• Measures impedances >100MΩ

• Solar cells

• 2-, 3- and 4-terminal measurement
configurations

• LCDs
• Bio-materials
• Ceramics / composites
• Electronic component development
• Civil engineering
Part of Solartron Analytical’s extensive
range of precision products designed to
provide cost effective solutions for dc
and ac analysis in electrochemical and
materials research, 1260 offers an
outstanding measurement specification
for impedance spectroscopy:
Huge frequency range
Spanning 10µHz to 32MHz with
0.015ppm resolution, 1260 provides
excellent coverage for virtually all
chemical and molecular mechanisms all in a single instrument.
Unbeatable accuracy
With an accuracy of 0.1%, 0.1º,
measurements can be made with
complete confidence, and even the
most subtle changes in sample
behavior detected and quantized.

The advantages of impedance
measurement over other techniques
include:-

• Polarization voltage up to ±40.95V
• Renowned ZPlot software package
simplifies experiments and optimises
throughput
Systems
When combined with other products
from Solartron Analytical’s range,
including well-proven application
software, 1260 can form the heart of
an advanced electrochemical and
materials measurement system, to
provide superb accuracy, flexibility and
reliability - even for the most complex
research problems.

• Rapid aquisition of data
• Accurate, repeatable measurements
• Non-destructive
• Highly adaptable to a wide variety of
different applications.
• Ability to differentiate effects due to
electrodes, diffusion, mass/charge
transfer by analysis over
different frequency ranges
• Equivalent circuit/modelling
techniques for detailed analysis of
results

Power supply
Power consumption
Dimensions (w x h x d)
Weight
Operating temp. range
Limit of error
Gain-phase
measurements
Applies to all ranges
at >10% full scale

1H

1k
H

1m
H
H
1µ

1k
100
10
1
100m
10m

1M

10M

100k

1k

10µ

Frequency (Hz)

1

10

1

0.1

0.01
1
Data source = V2/V1

1k

1M

Phase (degrees)

Results
Variable
Measured parameters

10k

6µA, 60µA, 600µA, 6mA, 60mA
200pA
±100mA
±250mA
single BNC
dc or ac (-3dB at Hz)
Solartron Analytical is a world leader in
instrumentation and software for the
characterization of materials and
1Mohm, <35pF
≥600µA range, 1Ω
electrochemical systems using
10kohm, 330pF
<600µA range, 50Ω
precision electrical measurement
Ambient temperature 20±10ºC, integration time >200ms. techniques.
Data valid for one year after calibration.
These techniques find particular use in
the fields of corrosion, battery and fuel
frequency, ac amplitude, dc bias
cell research, dielectric analysis and
voltage gain, phase, real, imaginary, Z, R, X, Y, G, B, V, I
electrochemistry. The product portfolio
group delay, C, L, Q, D
includes industry standard frequency
response analyzers, potentiostats,
90 to 126V, 198 to 252V, 48 to 65Hz
electrochemical software (Zplot and
230VA
CorrWare) and battery test equipment.
432mm x 176mm x 573mm (17in x 6.93in x 22.56in)
18kg (40lbs)
Arun Technology, an operating unit of
0 to 50ºC (32 to 122ºF)
Solartron Analytical, provides a range of

Magnitude (dB)

Limits of error

Current

1M
100k

10k

Voltage (2x)
operating in parallel
30mV, 300mV, 3V
1µV
±5V
±46V
single/differential BNC
floating/grounded
dc or ac (-3dB at 1Hz)

10M

100

Input System
3 independent analyzers
Ranges
Maximum resolution
Full scale peak
Inputs protected to
Connections
Shields
Coupling

100M

F
1µ

Sweep types
Maximum voltage
Maximum current
Impedance
Connection
Output disable

range: 10µHz to 32MHz, max resolution: 10µHz
error: ±100ppm, stability, 24hrs ±1ºC: ±10ppm
frequency (log or lin), ac/dc voltage, ac/dc current
hi to lo: ±46V peak, lo to ground: ±0.4V peak
±100mA peak
lo to ground: 100kΩ, <10nF
single BNC, floating shield
contact closure or TTL logic 0

Impedance Measurements
Applies for stimulation level of 1V for
impedances >50Ω or 20mA for
impedances <50Ω

F
1n

Frequency

Input impedance
Hi to shield
Shield to ground

Current mode
0 to 60mA rms
0 to 20mA rms
100µA
±100mA
200µA
>200kΩ at <1kHz

F
1p

Voltage mode
0 to 3V rms
0 to 1V rms
5mV
±40.95V
10mV
50Ω±1%

F
1m

Generator
ac Amplitude ≤10MHz
>10MHz
Maximum ac resolution
dc bias range
Maximum dc resolution
Output impedance

Impedance (ohms)

1260 Impedance/gain-phase Analyzer Specification

metal analyzers using optical emission
techniques for determining elemental
content. The units in static laboratory
or mobile format are used in foundries,
steelworks, or scrapyards for metals
analysis or material identification.

0.1
20M

Frequency (Hz)

Windows is a trademark of Microsoft Corporation
ZPlot and CorrWare are trademarks of Scribner Associates Inc.

Solartron Analytical
Unit B1 Armstrong Mall Southwood Business Park
Farnborough Hampshire GU14 0NR UK
Tel: +44 (0)1252 556800 Fax: +44 (0)1252 556899
19408 Park Row Suite 320
Houston Texas 77084-4860 USA
Tel: (1) 281-398-7890 Fax: (1) 281-398-7891
E-mail: info@solartronanalytical.com www.solartronanalytical.com
a Roxboro Group Company

Solartron Analytical's Quality
System is approved to
BS EN ISO 9001: 1994.
FM 01709

SA.1260/Iss04/0701



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:34fbd95d-aa1b-4e80-b8b9-35bc9770ba91
Producer                        : Acrobat Distiller 4.0 for Macintosh
Modify Date                     : 2005:06:21 11:57:14-05:00
Create Date                     : 2001:08:08 13:03:25Z
Metadata Date                   : 2005:06:21 11:57:14-05:00
Document ID                     : uuid:6d4bedbb-91b1-454e-9aa7-a6d00f12db3d
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools

Navigation menu