The world’s best-selling electric floor heating brand ™

END-KIT
INSTALLATION INSTRUCTIONS

DESCRIPTION
The Warmup End-Kit is a solid termination kit for NAMSR selfregulating cables.

APPLICATION
Used on both Roof & Gutter and for Pipe-Freeze Protection
applications, the End-Kit provides the installer with a solid,
mechanical cable termination. It saves time and materials over
traditional heat-shrinking techniques. These connection kits
must be installed according to NAMSR guidelines and minimum
installation temperatures.

APPROVALS

KIT CONTENT
Item

Qty

Description

A

1

Seal Plate for Main box

B

1

Main End Seal Box

C

1

(colour) Grommets

D

1

Label

REQUIRED TOOLS
•

Wire cutter

•

Nose pliers

•

Screwdriver

•

Tie Wrap

WARNING
The components are electrical devices. They must be installed
correctly to ensure proper operation and to prevent shock or fire.
Carefully follow all of the installation instructions and read these
important warnings.
•
To minimize the danger of fire from sustained electrical arcing
if the heating cable is damaged or improperly installed, and
to comply with the requirements of the national electrical
codes, ground-fault equipment protection must be used on
each heating cable branch circuit. Arcing may not be stopped by
conventional circuit protection.
•
Bus wires will short if they contact each other. Keep bus
wire separated.
•
Keep ends of heating cable and kit components dry before and
during installation.

WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com

•
•
•
•
•
•
•

The black heating cable core is conductive and can short. It must
be properly insulated and kept dry.
Component approvals and performance are based on the use
of specified parts only. Do not substituted parts or use
vinyl electrical tape.
Leave these installation instructions with the user for future
reference.
The heating cable should not be embedded in the thermal
insulation.
The cable should not be twisted during installation.
De-energize all power circuits before installation or servicing.
The conductive layer of this heating cable device must be
connected to a suitable grounding/earthing terminal.

CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca

The world’s best-selling electric floor heating brand ™

The world’s best-selling electric floor heating brand ™

END-KIT
INSTALLATION INSTRUCTIONS
PTC Cores
Outer jacket
Copper Braid

INSTALLATION INSTRUCTIONS

Outer jacket

Insulation
Bus wires

Cable with outer jacket for dry and wet conditions

1- Insert first the Pressure Seal End then the Grommet
into the cable.

4• Insert the heating cable into the main box.
• Install the grommet into position.
• Screw the Pressure Seal End into the main box.

2• Do not cut the braiding.
• Strip outer jacket.
• Slightly bend the cable where you made the cut to
strip it.

5• Affix the Low Profile End Seal Box and side wires to
the pipe with tape.
• Install insulation.
• Install label on the top of the insulation protector.
• Give instructions to the owner/user.

3- Remove excess braiding.

WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com

CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca

The world’s best-selling electric floor heating brand ™



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2016:05:10 09:14:32-04:00
Metadata Date                   : 2016:05:10 09:14:33-04:00
Modify Date                     : 2016:05:10 09:14:33-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:3ee3092a-81dc-4e6d-8828-fcdb4fc52b50
Original Document ID            : xmp.did:4031EE556476E51195C3B11B0B6A23A0
Document ID                     : xmp.id:F6BD0B14B116E611BEA0A22985A9929B
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:F5BD0B14B116E611BEA0A22985A9929B
Derived From Document ID        : xmp.did:C5495DFD72CBE5119962E5B26B2DB22B
Derived From Original Document ID: xmp.did:4031EE556476E51195C3B11B0B6A23A0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:05:10 09:14:32-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu