SPEEDFIT END Instructions
User Manual:
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
The world’s best-selling electric floor heating brand ™ END-KIT INSTALLATION INSTRUCTIONS DESCRIPTION The Warmup End-Kit is a solid termination kit for NAMSR selfregulating cables. APPLICATION Used on both Roof & Gutter and for Pipe-Freeze Protection applications, the End-Kit provides the installer with a solid, mechanical cable termination. It saves time and materials over traditional heat-shrinking techniques. These connection kits must be installed according to NAMSR guidelines and minimum installation temperatures. APPROVALS KIT CONTENT Item Qty Description A 1 Seal Plate for Main box B 1 Main End Seal Box C 1 (colour) Grommets D 1 Label REQUIRED TOOLS • Wire cutter • Nose pliers • Screwdriver • Tie Wrap WARNING The components are electrical devices. They must be installed correctly to ensure proper operation and to prevent shock or fire. Carefully follow all of the installation instructions and read these important warnings. • To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of the national electrical codes, ground-fault equipment protection must be used on each heating cable branch circuit. Arcing may not be stopped by conventional circuit protection. • Bus wires will short if they contact each other. Keep bus wire separated. • Keep ends of heating cable and kit components dry before and during installation. WARMUP INC. USA: us@warmup.com Tel.: 1-888-927-6333 www.warmup.com • • • • • • • The black heating cable core is conductive and can short. It must be properly insulated and kept dry. Component approvals and performance are based on the use of specified parts only. Do not substituted parts or use vinyl electrical tape. Leave these installation instructions with the user for future reference. The heating cable should not be embedded in the thermal insulation. The cable should not be twisted during installation. De-energize all power circuits before installation or servicing. The conductive layer of this heating cable device must be connected to a suitable grounding/earthing terminal. CANADA: ca@warmup.com Tel.: 1-888-592-7687 www.warmup.ca The world’s best-selling electric floor heating brand ™ The world’s best-selling electric floor heating brand ™ END-KIT INSTALLATION INSTRUCTIONS PTC Cores Outer jacket Copper Braid INSTALLATION INSTRUCTIONS Outer jacket Insulation Bus wires Cable with outer jacket for dry and wet conditions 1- Insert first the Pressure Seal End then the Grommet into the cable. 4• Insert the heating cable into the main box. • Install the grommet into position. • Screw the Pressure Seal End into the main box. 2• Do not cut the braiding. • Strip outer jacket. • Slightly bend the cable where you made the cut to strip it. 5• Affix the Low Profile End Seal Box and side wires to the pipe with tape. • Install insulation. • Install label on the top of the insulation protector. • Give instructions to the owner/user. 3- Remove excess braiding. WARMUP INC. USA: us@warmup.com Tel.: 1-888-927-6333 www.warmup.com CANADA: ca@warmup.com Tel.: 1-888-592-7687 www.warmup.ca The world’s best-selling electric floor heating brand ™
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2016:05:10 09:14:32-04:00 Metadata Date : 2016:05:10 09:14:33-04:00 Modify Date : 2016:05:10 09:14:33-04:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:3ee3092a-81dc-4e6d-8828-fcdb4fc52b50 Original Document ID : xmp.did:4031EE556476E51195C3B11B0B6A23A0 Document ID : xmp.id:F6BD0B14B116E611BEA0A22985A9929B Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:F5BD0B14B116E611BEA0A22985A9929B Derived From Document ID : xmp.did:C5495DFD72CBE5119962E5B26B2DB22B Derived From Original Document ID: xmp.did:4031EE556476E51195C3B11B0B6A23A0 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2016:05:10 09:14:32-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools