Sebalog D3 Daten Logger D_3 User Manual Brochure

User Manual: Sebalog-D_3-User-Manual-Brochure

Open the PDF directly: View PDF PDF.
Page Count: 81

DownloadSebalog D3 Daten-Logger Sebalog-D_3-User-Manual-Brochure Brochure
Open PDF In BrowserView PDF
Consultation with SebaKMT

User Manual
Data Logger

Sebalog D-3

Mess- und Ortungstechnik
Measuring and Locating Technologies
Elektrizitätsnetze
Power Networks
Kommunikationsnetze
Communication Networks
Rohrleitungsnetze
Water Networks
Abwassernetze
Sewer Systems
Leitungsortung
Line Locating

Issue:
Article number:

1

05 (12/2016) - EN
83914

Consultation with SebaKMT

2

Consultation with SebaKMT

Consultation with SebaKMT
The present system manual has been designed as an operating guide and for
reference. It is meant to answer your questions and solve your problems in as fast and
easy a way as possible. Please start with referring to this manual should any trouble
occur.
In doing so, make use of the table of contents and read the relevant paragraph with
great attention. Furthermore, check all terminals and connections of the instruments
involved.
Should any question remain unanswered or should you need the help of an authorized
service station, please contact:
Seba Dynatronic
Mess- und Ortungstechnik GmbH

Hagenuk KMT
Kabelmesstechnik GmbH

Dr.-Herbert-Iann-Str. 6
D - 96148 Baunach
Phone: +49 / 9544 / 68 – 0
Fax: +49 / 9544 / 22 73

Röderaue 41
D - 01471 Radeburg / Dresden
Phone: +49 / 35208 / 84 – 0
Fax: +49 / 35208 / 84 249
E-Mail: sales@sebakmt.com
http://www.sebakmt.com

 SebaKMT
All rights reserved. No part of this handbook may be copied by photographic or other means unless SebaKMT
have before-hand declared their consent in writing. The content of this handbook is subject to change without
notice. SebaKMT cannot be made liable for technical or printing errors or shortcomings of this handbook.
SebaKMT also disclaims all responsibility for damage resulting directly or indirectly from the delivery, supply,
or use of this matter.

3

Terms of Warranty

Terms of Warranty
SebaKMT accept responsibility for a claim under warranty brought forward by a
customer for a product sold by SebaKMT under the terms stated below.
SebaKMT warrant that at the time of delivery SebaKMT products are free from
manufacturing or material defects which might considerably reduce their value or
usability. This warranty does not apply to faults in the software supplied. During the
period of warranty, SebaKMT agree to repair faulty parts or replace them with new parts
or parts as new (with the same usability and life as new parts) according to their choice.
This warranty does not cover wear parts, lamps, fuses, batteries and accumulators.
SebaKMT reject all further claims under warranty, in particular those from consequential
damage. Each component and product replaced in accordance with this warranty
becomes the property of SebaKMT.
All warranty claims versus SebaKMT are hereby limited to a period of 12 months from
the date of delivery. Each component supplied by SebaKMT within the context of
warranty will also be covered by this warranty for the remaining period of time but for 90
days at least.
Each measure to remedy a claim under warranty shall exclusively be carried out by
SebaKMT or an authorized service station.
This warranty does not apply to any fault or damage caused by exposing a product to
conditions not in accordance with this specification, by storing, transporting, or using it
improperly, or having it serviced or installed by a workshop not authorized by SebaKMT.
All responsibility is disclaimed for damage due to wear, will of God, or connection to
foreign components.
For damage resulting from a violation of their duty to repair or re-supply items,
SebaKMT can be made liable only in case of severe negligence or intention. Any liability
for slight negligence is disclaimed.
Since some states do not allow the exclusion or limitation of an implied warranty or of
consequential damage, the limitations of liability described above perhaps may not
apply to you.

4

Terms of Warranty

Contents
Consultation with SebaKMT ...........................................................................................3
Terms of Warranty ...........................................................................................................4
1

Safety Instructions ...........................................................................................9

1.1

General Safety Instructions and Warnings .........................................................9

1.2

General Notes ....................................................................................................9

2

Technical description ....................................................................................11

2.1

Function ............................................................................................................11

2.2
2.2.1
2.2.2

Design ..............................................................................................................11
Controls and indicators.....................................................................................11
Connectors .......................................................................................................12

2.3
2.3.1
2.3.2

Communication ................................................................................................14
Log RI or Log RI+ radio interface .....................................................................15
Reader-3 used as radio interface .....................................................................15

2.4
2.4.1
2.4.2
2.4.3

Power supply ....................................................................................................16
Internal supply ..................................................................................................16
External power supply ......................................................................................16
Checking the battery status ..............................................................................17

2.5

Memory.............................................................................................................17

2.6

Technical data ..................................................................................................18

2.7

Scope of delivery and accessories ...................................................................19

2.8

Available versions ............................................................................................20

3

Commissioning the logger ............................................................................21

3.1

Preparations for mobile communication ...........................................................21

3.2

Preparing the logger for GSM ..........................................................................21

3.3

Switching the logger On/Off .............................................................................23

3.4

Programming the logger ...................................................................................23

4

Connecting the logger and installing it on-site ...........................................25

4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5

Connecting sensors to the logger ....................................................................25
Fixed channel allocations .................................................................................25
Connecting a hose to the internal pressure sensor .........................................26
Connecting sensors ..........................................................................................27
Connecting devices to the switching Inputs / Outputs .....................................28
Wiring diagram examples .................................................................................29

4.2

Positioning the logger .......................................................................................31

5

SebaDataView-3 software ..............................................................................33

5.1

Introduction .......................................................................................................33

5.2

Installation ........................................................................................................33

5.3

Function and structure ......................................................................................34

5

Terms of Warranty

5.4
5.4.1
5.4.2
5.4.3
5.4.4

Device administration .......................................................................................36
Creating / deleting folders ................................................................................36
Creating / deleting zones..................................................................................36
Creating / deleting groups ................................................................................37
Adding / deleting single devices .......................................................................38

5.5
5.5.1
5.5.2

Map function .....................................................................................................39
Creating a map .................................................................................................39
Executing a map...............................................................................................41

5.6
5.6.1
5.6.2

System settings ................................................................................................43
Managing the storage location of the measurement database ........................43
Saving access data for FTP server and email account ....................................44

6

Programming the logger using the SebaDataView-3 software..................45

6.1

Introduction .......................................................................................................45

6.2

Status of the device ..........................................................................................46

6.3

Selecting the logging interval ...........................................................................46

6.4
6.4.1
6.4.1.1
6.4.1.2
6.4.1.3
6.4.2
6.4.3

Configuring a measuring channel ....................................................................46
Selecting the type of sensor .............................................................................47
Configuring an Internal Pressure Sensor .........................................................48
Configuring a ‘user defined’ sensor..................................................................49
Input type examples .........................................................................................50
Configuring alarm conditions (Threshold monitoring) ......................................52
Finishing the sensor configuration ...................................................................55

6.5

Configuring the alarm inputs ............................................................................55

6.6
6.6.1
6.6.2

Configuring the mobile communication ............................................................57
Explanations about the GSM configuration dialogue .......................................58
Testing the mobile connection ('GSM test') ......................................................61

6.7

Adjusting the start time of data recording.........................................................62

6.8

Activate / deactivate circular buffer ..................................................................62

6.9

Adding a comment ...........................................................................................63

6.10

Sending the configuration data to the logger ...................................................63

7

Retrieving and evaluating data .....................................................................65

7.1

‘Realtime Measurement’ with SDV-3 software .................................................65

7.2
7.2.1
7.2.2

Retrieving measurement data ..........................................................................66
Reading out data using the PC/Laptop ............................................................66
Downloading data from a FTP server ..............................................................66

7.3

Managing saved measurement data ................................................................67

7.4
7.4.1
7.4.2
7.4.3

Displaying measurement data ..........................................................................68
Calling up a measurement ...............................................................................68
Using the measurement data display ...............................................................68
Displaying pressure surges ..............................................................................70

7.5

Exporting data in CSV format ...........................................................................71

8

Miscellaneous functions of the SebaDataView-3 software ........................73

6

Terms of Warranty

8.1

Find out status information of a device ............................................................73

8.2

Receiving an ‘Event List’ ..................................................................................74

9

Firmware update .............................................................................................75

10

Changing the battery .....................................................................................77

10.1

Ordering a battery-replacement kit ...................................................................77

10.2

Conduct the replacement .................................................................................77

10.3

Reset of the battery counter .............................................................................79

7

Terms of Warranty

8

Safety Instructions

1

Safety Instructions

1.1

General Safety Instructions and Warnings








1.2

Do not drop the device / the system’s components or subject it / them to
strong impacts or mechanical shocks.
The limits described under Technical Data may not be exceeded.
The device / system must be in a technically perfect condition for
measurement.
The indicated degree of protection can only be ensured if plugs or the
provided protection caps are put in all sockets of the device.
The plugs of the supplied connection cables are only compliant to the
indicated degree of protection as long as they are plugged in. Plugs
which are not connected or which are connected in a wrong way are not
protected from water and dust ingress.
If the O-ring seal of a socket is obviously damaged, it must be replaced
in order to ensure the total protection against water and dust ingress.

General Notes

Safety precautions This manual contains basic instructions for the commissioning and operation of the
device / system. For this reason, it is important to ensure that the manual is always
available to the authorised and trained operator. He needs to read the manual
thoroughly. The manufacturer is not liable for damage to material or humans due to nonobservance of the instructions and safety advices provided by this manual.
Locally applying regulations have to be observed!
Labelling of safety The following signal words and symbols are used in this manual and on the product
instructions itself:
Signal word /
symbol

Description

CAUTION

Indicates a potential hazard which may result in moderate or minor
injury if not avoided.

NOTICE

Indicates a potential hazard which may result in material damage if
not avoided.
Serves to highlight warnings and safety instructions.
As a warning label on the product it is used to draw attention to
potential hazards which have to be avoided by reading the manual.
Serves to highlight important information and useful tips on the
operation of the device/system. Failure to observe may lead to
unusable measurement results.

Check contents Check the contents of the package for completeness and visible damage right after
receipt. In the case of visible damage, the device must under no circumstances be taken
into operation. If something is missing or damaged, please contact your local sales
representative.
Working with products It is important to observe the generally applicable regulations of the country in which the
from SebaKMT device will be operated, as well as the current national accident prevention regulations
and internal company directives (work, operating and safety regulations).

9

Safety Instructions

Use genuine accessories to ensure system safety and reliable operation. The use of
other parts is not permitted and invalidates the warranty.
Repair and Repair and maintenance work has to be carried out by SebaKMT or authorised service
maintenance partners using original spare parts only. SebaKMT recommends having the system
tested and maintained at a SebaKMT service centre once a year.
SebaKMT also offers its customers on-site service. Please contact your service centre if
needed.
Special transportation The lithium batteries of the device are dangerous goods. The transport of the batteries
requirements itselves and of devices which contain such batteries is subject to regulations based on
the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1).
Please inform yourself about the transportation requirements and follow them when
shipping the device.
Electromagnetic This device is designed for industrial use. When used at home it could cause
radiation interference to other equipment, such as the radio or television.
The interference level from the line complies with the limit curve B (living area), the
radiation level complies with the limit curve A (industrial area) according to EN 55011.
Given that living areas are sufficiently far away from the planned area of operation
(industrial area), equipment in living areas will not be impaired.

For FCC:
- User Information acc. to FCC15.21:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
- Part 15 Statement gem. FCC 15.19/RSS Gen Issue 3 Sect. 7.1.3:
This device complies with Part 15 of the FCC Rules and with Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.

10

Technical description

2

Technical description

2.1

Function
Sebalog D-3 (in short: Log D-3) is a compact, robust and extremely versatile data
logger. The device can record the readings of various sensor types in user-defined
intervals. Depending on the configuration, up to 4 freely programmable channels can be
connected to sensors for data recording.
The logger also can provide an internal pressure sensor hoses can be connected to
directly. When using the internal pressure sensor, in addition to the standard pressure
measurement the recording of sudden pressure fluctuations (known as ‘pressure
surges’) is possible.
Using the ‘real-time measurement’ function or the ‘Step Test’ function, a measurement
can be carried out and observed ‘live’ on a computer.
The logger can be used for monitoring purposes, as it is able to trigger user-defined
alarm signals (e.g. signal lights, SMS or e-mail) if a threshold is exceeded or special
alarm equipment is triggered.
Recorded measuring data are stored in the loggers memory and can be retrieved via
short range radio. Loggers equipped with a GSM module can also send the data
regularely to an FTP server, from where they can be downloaded to any Internetcapable computer.
Programming of the device, as well as retrieving and evaluating the recorded measuring
data is performed by the help of the ‘SebaDataView-3’ PC software.

2.2

Design

2.2.1

Controls and indicators
The following figure shows the loggers’ ON/OFF switch and control lamp.

Item Description
On/Off contact area
I/O control lamp

11

Technical description

Control lamp states Here you find some possible states of the logger’s control lamp:

2.2.2

LED status

Description

green (1 x per sec)

logger is switched on

red (regularly)

logger is sampling (flashing is according to log interval)

blue (1x each 10 sec)

logger is checking for radio signal

blue (rapidly)

during data transfer via radio

blue (constantly)

during connection to radio signal

green (unsteady)

GSM operations are done, data are transmitted

green (constantly)

logger is dialing in to GSM network

red (constantly)

Error !!
 common GSM error, e.g. powering up modem failed,no
SIM card detected, dial in unsuccessful, error during ftp
data transfer - (LED turns off when modem was
successfully turned down)
 wrong PIN code - (flashing red 3x before turning on
constantly)
 SIM-card blocked, PUK needed - (flashing white 3x
before turning on constantly)

Connectors
The following figure shows the connectors of a fully equipped logger. Which connectors
are part of the assembly depends on the configuration of the logger.

Item Description
DC ext. socket
- for connecting an external power supply or alarm triggering devices
Connector P1
Pressure sensor (internal measuring channel: "Channel 1")
GSM socket
for connecting the external GSM antenna
IN socket
for connecting sensors or peripheral devices
For loggers that have two internal pressure sensors, the connections are arranged
somewhat differently (see next page).

12

Technical description

Loggers with 2 internal The following figure shows the connections or connection sockets of a logger with two
pressure sensors internal pressure sensors.

Item Description
DC ext. socket
for connecting an external power supply or alarm triggering devices
Connector P1
pressure sensor (internal measuring channel: "Channel 1")
GSM socket
for connecting the external GSM antenna
IN socket
for connecting sensors or peripheral devices
Connector P2
second pressure sensor (internal measuring channel: "Channel 3")

13

Technical description

2.3

Communication
The SebaDataView-3 software is used on a PC/laptop to program the logger before the
measurement and to retrieve the collected data after the measurement.
Short range radio is used for communication between the devices. The computer must
have a radio interface. For that purpose the ‘Log RI’ or "Log RI+" can be connected.
Furthermore, if your logger is equipped with an internal GSM module, measurement
data uploads to an FTP server or configuration data downloads to the logger are
possible.

GSM / GPRS / UMTS
Radio

Internet

External GIS or
SCADA system

SDV-3 PC software

Loggers, which are to be contacted via radio, have to be switched on and must
be situated within the wireless range of the computer or reading device.

14

Technical description

2.3.1

Log RI or Log RI+ radio interface

‘Log RI’ The compact ‘Log RI’ is the standard radio interface for communicating with devices of
the Sebalog series.

'Log RI+' The radio interface ‘Log RI+’ is available as accessory from SebaKMT. Compared to the
Log RI the device has a higher-performing radio module which allows a higher radio
range.

Use Simply connect the ‘Log RI’ / ‘Log RI+’ to a USB port of the computer. The device
switches itself on. The device is automatically detected by the computer and
immediately ready to establish the radio link. There are no further adjustments to be
done.
Status LED The device has a status LED:
 flashing 1x red, 1x green
 blue light
 red light

… switching on
… data transfer in progress
… malfunction

Update We recommend that the device is always operated with the latest firmware. More exact
information on how to update the firmware in Sebalog N-3 series devices is available in
its own chapter in this operating manual.

2.3.2

Reader-3 used as radio interface
The ‘Reader-3’ reading device from SebaKMT can be used to establish radio
communication, too.
Connect the Reader-3 to the USB port of your PC using the Docking Station and switch
it on. The device automatically starts in USB mode. It is automatically detected by the
computer and immediately ready to establish the radio link. There are no further
adjustments to be done. For further information please consult the operating instructions
of your Reader-3.

15

Technical description

2.4

Power supply

2.4.1

Internal supply
The device is powered by internal Lithium batteries. Depending on the variant, one or
two batteries can be installed.

Battery lifetime The effective lifetime of the batteries strongly depends on which functions are used and
how often they are used.
Using the following settings and under the following conditions a logger can be operated
for up to five years without changing the batteries.
Parameter

Setting

Channel 1

Internal pressure sensor

Channel 2

External sensor; Input signal: Pulse

Channel 3

External sensor; Input signal: Pulse

Channel 4

External sensor; Input signal: Pulse

Log interval

15 min

Event

Number

Data transfer via GSM

Once a day (SMS / e-mail / FTP upload)

Pressure surge recording

Once a day

Alarm events per day

No

Empty batteries When the batteries get low, the logger switches itself off. Measurement data, logged up
to that point, remain safely in the loggers’ memory until the next programming.
Flat batteries can be replaced (see page 77). A set of matching spare batteries is
available from SebaKMT.

2.4.2

External power supply
In order to expand the operating time of the measuring system, the logger can be
supplied by an external energy source.
The logger is connected to this source using the VK 76 connection cable (see page 28).


Supply voltage:

12 V



Supply current:

approx. 0.5 A (if the GSM function is not used)
approx. 1.5 A (when using the GSM function)

NOTE
Peaks of 4 A can occur.

External rechargeable There is an external rechargeable battery pack available from SebaKMT which can be
battery pack connected to the data logger in order to expand the operating time of the measuring
system.The logger is connected to the external battery pack by means of the VK88
connection cable. The 10-pole connector (red) of the cable has to be plugged in the

16

Technical description

DC ext.
socket of the logger. Then the 5-pole connector has to be plugged in one of
the sockets of the battery, no matter which one. From now on the logger is powered by
the external battery only, until the connection is cut or the capacitance of the external
battery gets low. In that case, the logger switches back to internal power supply.
Use the supplied mains adapter to recharge the external battery pack. Plug the round
5-pole connector in one of the sockets of the battery, no matter which one. Once the
battery is connected to the mains, it is charging. The charging process for a fully loaded
battery takes 12 to 13 hours. Overcharging of the battery cannot occur if the supplied
mains adapter is used.

2.4.3

Checking the battery status
The logger does not have a battery indicator. However, whenever the measured data or
configuration data are queried from the logger, information on the current battery status
of the logger is also sent to the receiver.
In the SebaDataView-3 Software, you can find the latest battery status in the device's
status information (see page 73).
To check the current battery status of a logger, you should read out the configuration of
this logger with the computer.

Requirements The following requirements must be fulfilled to do so:
 computer with SebaDataView-3 software
 a radio interface must be connected to the computer (e.g. Log RI)
 the logger must be registered in the software
 the logger must be switched on
 the device must be within the computer’s wireless range
Procedure Proceed as follows:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Program.
Result: In the State segment, the battery status may already be indicated.
However, this information only relates to the point in time of the last data readout
and is thus not current.

3

Click on Read.
Result: The configuration data is transferred from the logger and shown on the
screen of the computer. The battery level shown in the State segment is now upto-date.

2.5

Memory
The device has 4 MB internal memory. For example, if 4 sensors are connected and a
recording interval of 5 minutes is specified, this is sufficient for 5 years non-stop data
recording.
As part of the programming process, the logger can be set to "ring memory mode". As
the memory fills up with data in this mode, the device keeps logging and the respective
oldest value is overwritten.

17

Technical description

2.6

Technical data
Depending on the configuration, the Sebalog D-3 is specified by the following
parameters:
Parameter

Value

Communication

Short-range radio
868 MHz (in Europe)
913.02 MHz (in the US)
913 / 916 MHz (depending on the country)
Mobile radio (GSM / GPRS / UMTS)
850 / 900 / 1800 / 1900 / 2100 MHz

Inputs / outputs

2 or 4 freely programmable channels,
digital: 0…5 V / pulse / frequency
analogue:4…20 mA (max. 2 channels);
Up to 2 switching inputs (alarm trigger);
Up to 2 switching outputs (alarm installation);
Connectors for internal pressure sensor

Internal pressure sensor

optional (16 bar / 25 bar / 35 bar);
accuracy: +/- 1 %
resolution: 0.006 bar (16 bar sensor)

Log interval
standard measurement
pressure surge meas.

Standard measurement
1 sec up to 24 hrs selectable
Pressure surge measurement
0.1 sec or 1 sec selectable

Memory

4 MB internal memory
block or roll memory selectable

Alarm

Switching input and threshold monitoring for each channel
possible;
Triggering of switching output(s);
Alarm messages via SMS / e-mail;
Measuring data upload to FTP server in case of alarm

Battery

Internal lithium batteries

Ext. power supply

12 V DC

Operating temperature

-20°C … +70°C (-4°F … 158°F)

Storage temperature

-20°C … +70°C (-4°F … 158°F)

Dimensions (L x W x H)

approx. 185 x 115 mm

Weight

approx. 0.9 kg (incl. batteries)

Degree of protection

IP 68

18

Technical description

2.7

Scope of delivery and accessories

Scope of delivery The Sebalog D-3 package contains:
Accessory part

Description

Item No.

LOG D-3

Flow and pressure data logger

depends on
variant

CSW Dataview-3

SebaDataView-3 user software

118302210

Handbuch en

User manual

83914

Accessory set The LOG D-3-A (Item No. 1007011) accessory set contains:
Accessory part

Description

Item No.

VK 86

Connection cable for connecting up to 4 sensors

820019262

Hydraulikschlauch

Pressure hose, 2 m, 35 bar.

118304220

GSM-Antenne

GSM antenna with connection cable, 2 m

820020888

Optional The following optional accessory parts can be ordered from SebaKMT:
accessory parts
Accessory part
Description

Item No.

LOG D-EB

External accumulator set for the logger

820020355

VK 88

Connection cable for LOG D-EB

820020384

LG LOG D-EB

Charger for LOG D-EB

820021240

VK 75

Connection cable without connection box

820012449

VK 76

Connection cable with connection box

820012450

VK 84

Connection cable between Log D-3 and UDM 300 820018168

LOG RI

Radio interface forPC/laptop

820025783

LOG RI+

Radio interface forPC/laptop

1003877

19

Technical description

2.8

Available versions
The Sebalog D-3 data logger is available in a wide variety of configurations. The type
code on the logger’s label showshow the device is equipped..

Type code The type code consists of the following segments:

LOG D-3 4 G 16 - 2 - 868
frequency of the internal radio module in MHz
(here: 868 MHz)
number of internal pressure sensors
(here: the device has two pressure sensors)
top level of the internal pressure sensor's measuring range
in bar (here: max. 16 bar)
the logger is equipped with a GSM modem
number of logging channels
(here: the device has 4 measuring channels)

Due to the large amount of possible configurations, this manual cannot state
explicitly whether or not a described function applies to your device. Please use
the information provided within this section to identify the specific capabilities of
your logger.

20

Commissioning the logger

3

Commissioning the logger

3.1

Preparations for mobile communication
If your data logger is equipped with an internal GSM modem for mobile radio
communication, alarm messages and status messages can be sent via e-mail or SMS.
Furthermore, collected data can be transferred to an FTP server. From there they can
be downloaded with any Internet-capable computer anywhere in the world.

UMTS / GPRS / GSM For data transfer via mobile radio you have to close a suitable contract with a mobile
phone service provider, in order to get a SIM card enabled for data transfer via UMTS.
FTP server For measuring data uploads, free memory space on an FTP server is needed. You can
ask your administrator to set up an FTP server using the server infrastructure of your
company or you can rent a server from a commercial internet service provider.
You can also rent FTP space from SebaKMT. Please contact your SebaKMT distributor.
Under certain conditions the demo server run by SebaKMT can be used.
E-mail messages If you wish to receive alarm messages or status messages via e-mail, an e-mail account
is needed from which the messages are to be sent. If the mail server of your company is
not capable for this task (e.g. due to a firewall), a webmail account from an internet
service provider (e.g. Yahoo or Google) can be used instead.
Under certain conditions the demo account run by SebaKMT can be used.
Please note that the mobile radio link function increases the loggers’ energy
demand, which has a strong negative influence on the battery life of the logger.

3.2

Preparing the logger for GSM
In order to prepare the logger for GSM connectivity, the SIM card has to be inserted and
the GSM antenna must be connected. You received the SIM card from your mobile
operator when you concluded the mobile contract.

NOTE
Please be careful not to damage any parts. Don't use any force.

Insert SIM card Proceed as follows:
Step Description
1

The Logger has to be switched off.

2

Loosen the six screws on the device.

3

Loosen and remove the cover of the device. To do so, do not use tools, even if
the cover is extremely tight.
Result: Inside the housing you have access to the batteries and SIM card slot.
(continued on next page)

21

Commissioning the logger

Step Description
4

Insert the SIM card.
To remove the tray for the SIM card from its fastener, press the yellow spring
mechanism (e.g. by the help of a screwdriver or a pen). Remove the tray and
place the SIM card on it so it fits. Then push the tray back into the bracket until it
locks into place.

5

Attach the cover to the housing again.
The rubber seal inside the cover is not glued in and may possibly fall out.
Therefore, when re-assembling the device, it may be helpful not to put
the cover on the housing but to take both parts upside down and then put
the housing on the cover.

Note the following points when assembling.
 The rubber seals and the housing and cover surfaces which touch each other
must be free of dirt.
 Do not pinch the wires of the batteries!
 Do not jam cover when putting it on the housing!
 Tighten screws crosswise!
 Carefully tighten the screws finger-tight! Do not overtighten!

Connect GSM antenna The logger has no internal or external antenna. To enable the GSM connectivity the
delivered external GSM antenna must be connected to the device.
Connect the antenna to the GSM socket
. Make sure that the guide on the plug fits in
the groove in the socket and that you feel the plug latch in.

22

Commissioning the logger

3.3

Switching the logger On/Off
The logger is switched on by the help of a magnetic switch.

NOTE
Before switching the logger on, all connected devices have to be
disconnected (unplug connectors) because the internal relays of the logger
are initiated during the switch-on process. Thus, connected devices could be
turned on and off unexpectedly and unintentionally.

Move the supplied magnet in front of the contact area

. After the magnet switch has

been activated, the I/O control lamp
is lit green for a moment and starts flashing
blue after the logger has been started up. The device is now in energy saving mode.
Whenever a radio or GSM connection is established and whenever a data transfer takes
place, the logger automatically switches to data transfer mode.
In order to switch the logger off, the magnet must be held in front of the contact area
for a few seconds while the I/O control lamp
is lit orange. As soon as the lamp
switches to red, the magnet has to be taken away from the contact area. Afterwards, the
logger switches off and the lamp goes out. Make sure to take the magnet away
immediately after the lamp switches to red. Otherwise, the logger reboots right after it
has been switched off.
Switching the device off has no effect on the measurement data stored. The
measurement data remain in the logger’s memory up to the time at which the device
receives new configuration data.
After being switched off and on again, the logger’s latest configuration still is
stored and can be retrieved, but it is no longer valid. The logger does not resume
measuring.
Furthermore, after being switched off and on again, the logger’s system time is
no longer current.
Therefore, the logger needs to be programmed anew after every restart.

3.4

Programming the logger
Prior to its on-site installation, the logger must be properly configured using the supplied
SebaDataView-3 software. In doing so, the logger has to be provided with the channel
allocation, the alarm conditions and the wireless connection parameters among other
things.
Please refer to the according chapter in order to get a detailed description of how to
configure the logger (see page 45).

23

Commissioning the logger

24

Connecting the logger and installing it on-site

4

Connecting the logger and installing it on-site

4.1

Connecting sensors to the logger
Depending on its configuration, the following peripheral and measuring devices can be
connected to a logger:
 up to 4 sensors can be attached and the data can be logged (e.g. pressure, flow)
 up to 2 alarm-triggering devices (e.g. a light barrier) can be connected to the
switching inputs
 up to 2 devices (e.g. signal lamp, pump) can be connected to the switching outputs
and can be triggered in the case of an alarm
 one hose can be directly connected to the internal pressure sensors
Depending on the type of sensors / alarm devices connected, the appropriate parameter
values have to be provided to the logger using the SebaDataView-3 software. Please
refer to the according chapter in order to get a detailed description of the necessary
configuration steps (see page 45).
External sensors connected cannot be supplied by the data logger. They need a
separate power supply.

4.1.1

Fixed channel allocations
The internal pressure sensors P1 and P2 are always linked to measuring channel
1 and 3. If your logger is equipped with internal pressure sensors, the respective
channels are in use and must not be connected to external sensors.
Due to the internal wiring of the logger, current loops can only be connected to the
channels 2 and 4.
Corresponding to these conventions, the following channel allocations apply:
Channel 1

Channel 2

Channel 3

Channel 4

X

Internal pressure sensor P1

X

Internal pressure sensor P2
X

First current loop

X

Second current loop

Please pay attention to this assignment both when connecting sensors as well as when
selecting the measuring channels when programming the logger.

25

Connecting the logger and installing it on-site

4.1.2

Connecting a hose to the internal pressure sensor
If your logger is equipped with one or two internal pressure sensors, hoses can be
connected directly to the connectors P1
or P2
. In order to do so, your hose has
to be equipped with a female quick-fit connector.

NOTE
When connecting a hose to the internal sensor, the following instructions
must be noted:
 Pressure sensors are sensitive to overpressure. Do not exceed the
measuring range in order to avoid irreparable damage to the sensor.
 Make sure no dirt or rust can ingress inside the sensors. In case of
doubt, use a filter.
 After use or prior to storage for a longer period, each pressure sensor
must be cleaned with compressed air. There must not be any water
inside the sensor after use. Otherwise, frost can damage the sensor.
The sensors are capable of measuring the pressure of both liquid and gaseous media.

26

Connecting the logger and installing it on-site

4.1.3

Connecting sensors
Any connection of a sensor is established via the VK86 connection cable attached to the
IN socket
.
One end of the connection cable is equipped with a box providing a terminal block the
colour-coded wires coming from the logger are connected to. Each colour represents a
specific input / output of the logger.

green
(to be connected to IN)

The VK86 connection cable has the following pin assignment:
Wire

Description

white

Channel 1 +

brown

Channel 1 –

green

Channel 2 +

yellow

Channel 2 –

grey

Channel 3 +

pink

Channel 3 –

blue

Channel 4 +

red

Channel 4 –

black

not used

purple

not used

Channels up to 4 sensors can be connected to.

To connect a sensor, lead its connecting wires into the box using one of the four cable
glands and connect them to the respective terminal of the terminal block.
When you connect the cable to the IN socket of the logger, make sure that the guide on
the plug fits in the groove in the socket and that you feel the plug latch in.

NOTE
When you install the measuring system please keep in mind that water and
dust can penetrate the box.

27

Connecting the logger and installing it on-site

4.1.4

Connecting devices to the switching Inputs / Outputs
The switching input / output connections and the external power supply are established
via the VK76 connection cable attached to the DC ext. socket
.
One end of the cable is uncoated and ten colour-coded wires stick out of it. According to
its colour, each of these wires represents a specific input / output of the logger and can
be directly connected to the respective terminal of a peripheral device.

red
(to be connected to
DC ext.)

The VK76 connection cable has the following pin assignment:
Wire

Description

white

Switching Input 1

green

Switching Input 2

brown

Relay 1 OUT

yellow

Relay 2 OUT

pink

Relay 1&2 IN

red

External power
supply

purple

GND

grey

not used

blue

not used

black

not used

An alarm-triggering device with a voltage output of
0 … 5 V can be connected between a switching input
and the purple wire (GND).
An electric circuit with an external DC power supply up
to 12 V / 1 A can be connected to each switching
output. If an internal relay is triggered by an alarm
event, the respective circuit is closed and the
connected load is activated / triggered.
An external power supply with 12 V DC can be
connected between this wire and the purple wire
(GND). The internal battery cannot be charged by an
external power supply.

If no adequate terminals are existent, a luster terminal or other accessories can be used
to connect a peripheral device. A proper electrical insulation must be ensured.
Make sure that the guide on the plug of the VK76 cable fits in the groove in the
DC ext. socket and that you feel the plug latch in.

28

Connecting the logger and installing it on-site

4.1.5

Wiring diagram examples
In the following, some connection examples are described. Depending on the sensor,
the actual wiring diagram and the terminal designation may differ. Please refer to the
respective sensor manual for detailed information.

Output signal type The following example describes how to connect a sensor
voltage/frequency/ 0 - 5 V voltage output or 0 Hz - 6000 Hz frequency output or pulse output:
pulse

with

a

Logger

Sensor

Signal

Channel +

GND

Channel –

Output signal type The following example describes how to connect a sensor to a 4 … 20 mA current loop:
current
Logger

Sensor

I+

Channel +

I–

Channel –

NOTE
A current loop can only be connected to channel 2 or 4.

29

Connecting the logger and installing it on-site

Example of an The following example shows an electrical circuit with DC power source connected to
alarm loop the switching input of the loggers. If an alarm is raised by the alarm device (e.g. light
barrier) is activated, the circuit is closed and the switching input is triggered. Depending
on the alarm configuration, one or two of the internal relays are switched in order to
activate / trigger the load connected to the respective switching output (in this case a
signal lamp) and a SMS and / or e-mail can be sent to predefined receivers.
Alarm device

Logger
Alarm IN

Relay IN

configured
alarm trigger

GND

Relay OUT

GSM

SMS

e-mail

Alarms can also be triggered when the value of a monitored measurement crosses a
predefined threshold. Please refer to the corresponding section for detailed information
on how to configure the threshold monitoring (see page 52).

30

Connecting the logger and installing it on-site

4.2

Positioning the logger
The logger housing is protected against the ingress of dust and water and, thus,
especially qualified for the operation in pipeline shafts where it can be installed next to
the measuring point.
The logger can be installed in vertical and horizontal position or even upside-down and it
can also be hung up using, e.g., a cable tie.

General advices During field installation the following instructions must be observed, in order to ensure
proper operation of the logger:
 Make sure that all connections to sensors of other peripheral devices are
established in a professional manner and that the connection points are properly
insulated.
 When you plug a connection cable in the respective socket, make sure you feel the
plug latch in. Only proper and positive locking connections provide protection
against ingress of water and ensure error-free data transfer.
 Unused sockets must be sealed with the protective caps.
 Do not bend the connection cables.
 Care shall be taken to ensure that cables and their connections are not subjected to
tensile load.
 Do not hang the logger on its connection cables.
 Make sure the logger is switched on and programmed before you leave the site.
Additional advices for You have to observe the following instructions when positioning the GSM antenna:
loggers with GSM
 The GSM antenna must be properly connected to the logger. Make sure that the
guide on the plug fits in the groove in the GSM socket
and that you feel the
plug latch in.
 Be aware that thick walls and other barriers do affect the signal strength negatively.
 If the logger is installed underground, e.g. in a pipeline shaft, the antenna should be
positioned as near as possible to the ground surface. The deeper the antenna is
positioned, the smaller is the chance of an adequate reception.
Check the GSM connectivity using the GSM test function of the SebaDataView-3
software (see page 61) right after the GSM antenna has been positioned.
If no connection can be established, a better position has to be found. If necessary, lead
the antenna out of the shaft and bury it a few centimetres under the ground surface.

31

Connecting the logger and installing it on-site

32

SebaDataView-3 software

5

SebaDataView-3 software

5.1

Introduction
SebaDataView-3 (abbreviation: SDV-3) is the multifunctional application software for
working with devices in the ‘Sebalog’ series. You can use it to configure devices and
read out the measurement data from the devices. The measurement data can be
displayed and analysed in greater detail using various functions on the computer.

5.2

Installation

System requirements Your machine must meet the following minimum system requirements in order to run the
SebaDataView-3 software:
 PC or notebook with Windows 7® or higher
 min. Pentium IV compatible CPU (at least 2 GHz)
 min. 2 GB memory
 USB interface
 CD ROM drive
Installation To install the software insert the provided CD, execute the installation file and follow the
instructions on the screen. The application is installed to the following folder:
C:\Program Files\SebaKMT\SebaDataView.
Furthermore, a database is created in the Windows standard folder for application data.
Software start Start the application by double-clicking on the desktop icon created during the
installation process. Alternatively, the application can be started via the Windows start
menu.
Language selection During start-up you are asked to select the language of the user interface. Make your
choice from the drop-down-list and click on OK.
Software update During start-up, the current version of the software is displayed on the screen. Please
check www.sebakmt.com regularly for updates. To install a new version of the software,
store the respective file on your PC, execute it and follow the instructions on the screen.

33

SebaDataView-3 software

5.3

Function and structure

Introduction SebaDataView-3 (SDV-3) is the multifunctional user software for working with devices of
the Sebalog series. Using the software, loggers can be programmed prior to the
measurement. After measurement the recorded data can be queried from the loggers,
displayed and analyzed.
User interface The SDV-3 user interface is based on the Microsoft Office suite (2007 and later).
In all menu levels the display shows the following structure:

Multifunction
bar (ribbon)

Directory tree

Display area

Multifunction bar All function and command buttons are arranged in a panel, called ‘ribbon’, as it is known
from Microsoft Office applications.
Every Sebalog device series that can be managed using the SDV-3 software has its
own ‘tab’. All the commands needed when working with this device are grouped in the
‘segments’ of this tab.
Tabs

Segments

Display area All dialogue and display windows of the various functions appear in the display area.

34

SebaDataView-3 software

Directory tree On the left of the screen the directory structure of the software database is displayed. All
the devices added to the database by means of their identification number can be found
in this so called ‘directory tree’.
The directory tree shows the following structure of folders and sub-folders:
Main folder
Folder
Zone

Group

Type of device
Single device (ID)

35

SebaDataView-3 software

5.4

Device administration

5.4.1

Creating / deleting folders

Create a folder To create a new folder in the directory tree, proceed as follows:
Step Description
1

Mark the folder ‘SebaData’, or any other existing folder which the new folder
should be added to as a sub-directory.

2

Open the tab Directory in the multifunction bar.

3

In the segment Folder, click on New.

4

In the window which opens, enter the Name and a Comment for the new folder
and confirm the entries by pressing OK.
Result: The new folder has now been created in the database and will appear in
the directory tree.

Delete a folder To remove a folder from the directory tree, proceed as follows:
Step Description
1

Mark the folder to be deleted.

2

Open the tab Directory in the multifunction bar.

3

In the segment Folder, click on Delete.

4

Answer the security query with Yes.
Result: The corresponding folder is removed from the directory tree.

If a folder is deleted, all loggers/devices assigned and all the collected data are
deleted, too.

5.4.2

Creating / deleting zones

Create a zone To create a new zone in the directory tree, proceed as follows:
Step Description
1

Mark the folder in the directory tree in which the new zone should be created.

2

Open the tab Directory in the multifunction bar.

3

In the segment Zone, click on New.

4

In the window which opens, enter the Name and a Comment for the new zone
and confirm the entries by pressing OK.
Result: The new zone has now been created in the database and will appear in
the directory tree.

36

SebaDataView-3 software

Delete a zone To remove a zone from the directory tree, proceed as follows:
Step Description
1

Mark the zone to be deleted.

2

Open the tab Directory in the multifunction bar.

3

In the segment Zone, click on Delete.

4

Answer the security query with Yes.
Result: The corresponding zone is removed from the directory tree.

If a zone is deleted, all loggers/devices assigned and all the collected data are
deleted, too.

5.4.3

Creating / deleting groups

Create a group To create a new group in the directory tree, proceed as follows:
Step Description
1

Mark the zone in the directory tree in which the new group should be created.

2

Open the tab Directory in the multifunction bar.

3

In the segment Group, click on New.

4

In the window which opens, enter the Name and a Comment for the new group
and confirm the entries by pressing OK.
Result: The new group has now been created in the database and will appear in
the directory tree.

Delete a group To remove a group from the directory tree, proceed as follows:
Step Description
1

Mark the group to be deleted.

2

Open the tab Directory in the multifunction bar.

3

In the segment Group, click on Delete.

4

Answer the security query with Yes.
Result: The corresponding group is removed from the directory tree.

If a group is deleted, all loggers/devices assigned and all the collected data are
deleted, too.

37

SebaDataView-3 software

5.4.4

Adding / deleting single devices

Add a device To add a device to a group in the directory tree, e.g. a logger, proceed as follows:
Step

Description

1

Mark the group in the directory tree to which the device should be added.

2

In the multifunction bar, open the tab LogD3/SebaFlow/TDM300.

3

In the segment Administration, click on New.

4

In the window which opens, enter the Identification Number (ID) of the device or
use the "Automatic detection" (find more information below in the text).
Click on OK to add the device to the group.
Result: The new device has now been created in the database and will appear
in the directory tree.

Add more devices to the group successively or close the window.

There is the possibility to add devices of different types to the same group. Then,
automatically new sub-directories are created by the software to which the
various devices are added according to their type.
Example: "Group A" has Log N3, LogDX, Log D3 and SebaFlow devices:

Automatic detection A radio interface (e.g. Log RI) needs to be connected to the computer in order to be able
to use the „Automatic detection“ when signing on devices.
Tick the checkbox „Automatic detection“ in the window which opens. Then bring the
device which has to be turned off near the computer and switch it on. The identification
number of the device will be recognised and displayed on the screen.
Click OK or Insert in order to accept the ID and to add the device to the group.
If you tick the checkbox „Automatic insertion“, the recognised devices will be added
automatically to the group.
Delete a device To remove a device from the directory tree, proceed as follows:
Step Description
1

Mark the device to be deleted.

2

In the multifunction bar, click on Delete.

3

Answer the security query with Yes.
Result: The corresponding device with all its measuring data is removed from
the directory tree.

38

SebaDataView-3 software

5.5

Map function
You have the opportunity to mark the location of installation of each of your devices on a
virtual map. Thus, you obtain an overview of the zone and all the devices used.

5.5.1

Creating a map

Introduction You have the chance to import any image file into the software - e.g., a sector of a pipe
network plan or a detail of a map, etc.
If you have access to the Internet, the software also provides the possibility to call up
the ‘Google Maps’ web service, in order to create a map of the respective zone.
Import an image file To import an image file and add it to a zone in the directory tree, proceed as follows:
Step Description
1

Mark the zone in the directory tree to which the map should be added.

2

Open the tab Directory in the multifunction bar.

3

In the segment Pipe network, click on Graphic file.

4

Use the window that opens to navigate to the source folder, from where the image
file is to be imported (‘jpg’, ‘bmp’ and ‘png’ format are possible).
Select the file and click on OK.
Result: The image file is imported into the software and now appears in the
directory tree in the form of a sub-folder called Map.
A new window opens, where the newly created map is shown.

5

To mark the place of installation of a device, in the directory tree click on the
device concerned, keep the left mouse button pushed and drag the device to the
point desired on the map displayed.
Proceed in the same way to place the other devices of the zone on the map.

Create a map using To create a map using the ‘Google Maps’ web service and add it to a zone in the
‘Google Maps’ directory tree, proceed as follows:
Step Description
1

Mark the zone in the directory tree to which the map should be added.

2

Open the tab Directory in the multifunction bar.

3

In the segment Pipe network, click on Google Maps.
Result: A connection to ‘Google Maps’ is established. A new window opens,
showing the known ‘Google Maps’ user interface. Aditionally, you find some input
fields and controls.
If there are GPS position data stored for the devices of the zone, the appropriate
map section is displayed automatically.

4

To get a certain destination area displayed, use one of the following options:
 Mark the checkbox Address and enter the destination adress desired into the
field right beside, or
 mark the checkbox Coordinate and enter a GPS position, using the fields
Latitude and Longitude.
Confirm your entry by pressing the ENTER key on your keyboard.
(continued on next page)

39

SebaDataView-3 software

Step Description
5

Use the known tools of the ‘Google Maps’ user interface (moving, zooming, etc.)
to customize the map section displayed.

6

Click on OK.
Result: The adjusted map section is stored as an image file and now appears in
the directory tree in the form of a sub-folder called Map.
A new window opens, where the newly created map is shown.

7

To mark the place of installation of a device, in the directory tree click on the
device concerned, keep the left mouse button pushed and drag the device to the
point desired on the map displayed.
Proceed in the same way, in order to place the other devices of the zone on the
map.

40

SebaDataView-3 software

5.5.2

Executing a map
To open the map window of a zone, in the directory tree double-click on the Map
sub-folder of the zone concerned.
Menu bar

Map section

The markings, indicating the positions of the single devices on the map, show the
following design:
Symbol of the
type of device

Device identification
Thanks to the pictogram (symbol), the type of device marked can easily be recognized.
The text box shows ‘type & identification number’ or the ‘comment’ of the device marked
- depending on the settings made in the Pipe network segment of the menu bar (see
page 41).
Create a marking To mark the place of installation of a device, in the directory tree click on the device
concerned, keep the left mouse button pushed and drag the device to the point desired
on the map displayed.
Move a marking To move a marking on the map, proceed as follows:
Step Description
1

In the menu bar of the window, click on Select.
Result: The mode of the cursor changes from ‘show’

to ‘select’

.

2

Click on the marking concerned, keep the left mouse button pushed and move it
to a new position.

3

Finally, click on the Select button once again in order to deactivate it.

41

SebaDataView-3 software

Zoom function You have the chance to get a section of the map magnified in an extra window.
Proceed as follows:
Step Description
1

In the menu bar of the window, click on Zoom.
Result: The cursor changes from mode „show“

2

to mode „enlarge“

.

On the map, mark the area that is to be magnified.
(For this, click on the map, keep the left mouse button pressed and move the
cursor diagonally across the area of interest.)
Result: The map section selected is magnified.

Undo last step

In order to undo the last steps click the arrow button

in the menu bar.

In order to leave the magnified map view click once again the Zoom button.

Costumize the view You have the chance to costumize the map view. For this purpose, open the Directory
tab of the multifunction bar. There, in the Pipe network segment, the following
checkboxes are available:
Option

Description

100 %

If this checkbox is enabled, the map section is scaled up or down
corresponding to the size of the window displayed
If it is disabled, the size of the map remains static.

Show text

If this checkbox is disabled, the text box of the markings is hidden.

Show symbol

If this checkbox is disabled, the pictogram of the markings is hidden.

Show device ID

If this checkbox is enabled, the text box of a marking shows the type
and the identification number” of the device.

Show comment If this checkbox is enabled, the text box of a marking shows the
comment/name of the device.

42

SebaDataView-3 software

5.6

System settings
In the System settings menu you can make various basic settings for use of the SDV-3
software or specify frequently recurring parameters etc.
To open the menu, first click the water drop symbol
Settings button in the appearing context menu.

in the top left. Then, click the

A new window appears showing the system settings menu:

5.6.1

Managing the storage location of the measurement database
During installation of the software, a directory with the name ‘data’ is created on the
computer by default. All recorded data is saved to this directory.
In the system settings of the software, you have the option to display the current storage
location of the measurement data or set up another storage location.
To get access to the storage location management tools, you have to open the Default
tab.

Displaying the To display the current storage location of the measurement data, click Open in the
storage location Database storage location segment. The current target directory opens in an Explorer
window. (With the default setting, it is the ‘data’ directory mentioned above.) The precise
target path is displayed in the address line.
Changing the You have the option to define another storage location in place of the standard target
storage location directory of ‘data’.
Select the Other radio button in the Database storage location segment. Then click
Search (Browse) and use the Explorer window that opens to set a new target directory.
After the next restart of the software, all newly saved measurement data will be saved in
this folder. All previously saved measurement data remains in the previous target folder.
There is no longer access to this data from SDV-3.
If you define a new storage location and want to still have access to the previously
saved measurement data, you need to first move the entire previous target directory to
the new storage location. Only after you do this should you set the new target path, as
described above, by selecting the Other checkbox and defining the new target path by
pressing the Search (Browse) button.

43

SebaDataView-3 software

5.6.2

Saving access data for FTP server and email account

Introduction Various devices in the Sebalog series are equipped with an integrated GSM modem.
This means that they can
 send messages per SMS or email (e.g. alarm messages), as well as
 upload measurement data to an FTP server.
Every time the devices are programmed the access data for the sending email account
or the access data for the FTP server being used must be entered.
If you wish you can save the data for an email account as well as the FTP server data
permanently in the software. When programming the saved access data can then simply
be accepted into the input screen ‘with a click of the mouse’.
Procedure To store access data in the software, proceed as follows:
Step Description
1

In system settings open the FTP tab.
Result: The following entry screen then appears in the window:

The FTP Settings segment contains boxes for entering access data for your FTP
server. You can ask your company's system administrator or the server operator
for this data or it is available in your FTP usage agreement.
The Email Settings segment contains boxes for entering the access data for the
sender email account, if messages are to be sent per email. The data will be
assigned to you by the operator of the mail account, or by your system
administrator. In the Sender name field, you can enter any name, which will
subsequently be used to identify the device which is the sender of the alarm
message.
2

Click the relevant Use own settings checkbox.

3

Enter the access data in the input fields.

4

Click on OK to confirm the details and to close the window.
Result: The access data are now permanently stored in the software. When
programming the devices a checkbox is shown for each of the steps in the entry
area, with which the stored access data can then be inserted.

Only when the Use own settings checkbox has been activated will it be possible
at a later stage to access the stored data for programming purposes.
If the checkbox has not been activated, the user is then offered a choice of using
a SebaKMT demo FTP server and/or a demo email account.

44

Programming the logger using the SebaDataView-3 software

6

Programming the logger using the SebaDataView-3 software

6.1

Introduction
Before use, the logger must be programmed. During this process, the settings are
defined for mobile service, the measurement channels of the device are adjusted to the
connected sensors, the measurement interval and the measurement period are set and
possible alarm thresholds are defined, etc.
Programming is performed on the computer using the SebaDataView3 software.

Programming The configuration data is transferred via short range radio to the logger and immediately
via short range radio installed there.
For that, the following requirements must be met:
 a radio interface must be connected to the computer (e.g. Log RI)
 the logger must be switched on
 the logger must be within the computer’s wireless range
Programming Loggers with a GSM modem can, after initial programming, also be remotely
via mobile radio programmed from the office via an FTP server.
For that, the following requirements must be met:
 computer with SebaDataView-3 software
 the access data for the FTP server must already be saved in the configurations of
the SebaDataView-3 Software (see page 44)
 the logger must be known to the FTP server, meaning at least one data upload from
the logger to the server must have already taken place
 the logger has to be switched on
Saving measuring data With the programming, the measurement data memory of the logger is also reset,
meaning all previous data will be deleted.
If there is measured data stored in the device that needs to be saved, it must be read
out of the logger before programming (see page 66).
Procedure In order to program the device, proceed as follows:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Program.
Result: The window for programming opens.

(continued on next page)

45

Programming the logger using the SebaDataView-3 software

Step Description
3

Query the current configuration of the logger.
(This step is not absolutely necessary in all cases, but it is recommended to
nevertheless always perform the step instead of skipping it.)

If you want to read the data directly from If you want to download the data from
the device via radio, click on Read.
the FTP server, click on Read settings.
Result: The current configuration data is Result: The current configuration data is
read out and displayed.
download and displayed.
All input fields are now editable.
All input fields are now editable.
4

Enter or change the configuration data
(see next sections).

Change the configuration data (see next
sections).

5

Finally, click on Program.

Finally, click on Write settings.

Result: The new configuration data is
transmitted via radio to the logger and
installed there.

Result: The new configuration data is
upload to the FTP server. From there, it
is downloaded by the logger at the next
planned contact and then installed on
the device.

You find detailed information about the necessary programming steps in the following
sections.

6.2

Status of the device
In the State segment current status information about the device can be found, such as
the firmware version used, the internal time, battery status etc.
The Resulting storage periode line indicates how long the device can continue to
measure with the currently set parameters until the device memory is full.

6.3

Selecting the logging interval
You can select the time interval in which the measured values are logged from the
Log Interval drop-down list.

6.4

Configuring a measuring channel

Introduction Depending on its configuration, up to 4 sensors can be connected to a logger. In order
to evaluate the logged data in the right way, the logger needs to know which type of
sensor is connected to which channel.
Make sure that the sensor configuration is consistent with the effective connection
setup. Each channel is linked with specific wires of the VK86 connection cable (see
page 27).
Please pay regard to the fixed channel allocations (see page 25) when configuring
internal pressure sensors or sensors with current output.
Make sure you enter the values in the same format as shown in the figures.

46

Programming the logger using the SebaDataView-3 software

Activating channels In the Sensor configuration segment, the measurement channels of the logger are
listed.
Activate the measurement channels to which the sensors are connected. To do so, tick
the checkbox of the corresponding channel.

Only when a channel is "activated" is the measured data of the connected sensor
recorded by the logger. Not activated channels are ignored during the measurement.
If a logger is equipped with fewer than four measurement channels, then in the
input screen, only channels that actually exist in the device are available for
selection.
Configuring a channel After a channel has been activated, it has to be specified which type of sensor is
connected to the channel.
Click the respective Configure button. A new window appears.

6.4.1

Selecting the type of sensor
The physical value measured by the sensor is transformed into an electrical signal (e.g.
voltage, pulses, frequency) which is used to transmit the data to the logger. In order to
transform this carrier signal back into the original physical values, the logger needs to
know how the ranges are correlated to each other.

Procedure Select the sensor connected to the channel from the drop-down list on the upper left of
the window. If your sensor type is not contained in the drop-down list, select the
User-defined entry.

47

Programming the logger using the SebaDataView-3 software

The sensors contained in the list are parameterized. The signal conversion data are
already populated and cannot be edited. Usually, no further configuration is required.
In some cases you have the chance to specify the unit for the recorded values e.g. ‘bar‘ or ‘l‘.
Furthermore, with some flow sensors you have the chance to compare your results to
the values of a water meter. For this purpose, enter the water meters’ meter reading
into the displayed field prior to the measurement. The logger will then accept this count
as a starting point for the measurement.

6.4.1.1

Configuring an Internal Pressure Sensor
Most parameters of the internal pressure sensor are filled in automatically and cannot
be edited.

Unit You have the chance to select the unit for the recorded pressure. Use the drop-down
list. If the desired measuring unit is not offered, select the option User defined. A new
input field opens. Enter the desired measuring unit there.
Recording If you want sudden pressure fluctuations, known as pressure surges, to be recorded in
pressure surges addition to the standard pressure measurement, select the Record Press Shocks
checkbox
Using the input field to the right of the checkbox, you specify how much a measuring
value has to differ from the previous value in order to classify a pressure fluctuation as a
‘pressure surge’.
Example:
If ‘0.5’ is set, pressure surge recordings start as soon as a measuring value
is min. 0.5 bar higher or lower than the preceding value.
By means of the High resolution checkbox you can specify which sampling interval
should be used for the 60 second pressure surge recordings:
 checkbox de-selected: 1 sec sampling interval
 checkbox selected: 0.1 sec sampling interval
Using the short 0.1 sec interval allows a more detailed recording.
Please note that the high resolution recording of pressure surges requires more
energy and, thus, has a strong negative impact on the logger’s battery life.

The recording of pressure surges is parallel to the standard pressure measurement and
has no effect on this.

48

Programming the logger using the SebaDataView-3 software

6.4.1.2

Configuring a ‘user defined’ sensor
In the case of a ‘user defined’ sensor which is not contained in the mentioned
Drop-Down-List, the input type (carrier) and the unit of the physical value have to be
specified manually. Furthermore, the upper and lower thresholds of the input signal and
the correlating measurement values have to be specified.

Procedure Perform the following steps to configure the input type of a ‘user defined’ sensor:
Step Description
1

Select the type of signal, the sensor uses to pass the measured data to the logger
from the Input type drop-down list - e.g. "Voltage 0-5V".

2

Select the unit of the physical value measured by the sensor from the Unit dropdown list - e.g. "bar".
If the desired measuring unit is not offered, select the option User defined. A new
input field opens. Enter the desired measuring unit there.

3

Depending on which input type or which unit was selected, additional input fields
are displayed.
Assign the smallest possible input value to the smallest possible output value (in
the figure at "Start value").
Assign the largest possible input value to the largest possible output value (in the
figure at "End value").

Input signal thresholds

Correlating measured values

For detailed information about the input type and the ranges, please refer to the
manual of the connected sensor.

Negative value Output values with a negative value can also be defined.
Example (Temperature sensor):

0,0 V is equal to -20°C
5,0 V is equal to 50°C

For flow sensors, the sign of the output value indicates the flow direction of the fluid,
meaning:
 positive sign = forward flow
 negative sign = backward flow
Example:

4 mA is equal to -5 l/s (means 5 l/s backward flow)
20 mA is equal to 5 l/s (means 5 l/s forward flow)

49

Programming the logger using the SebaDataView-3 software

6.4.1.3

Input type examples

Input type Voltage A 10 bar pressure sensor with voltage output is connected to a channel of the logger.
Input type:
Unit:

Voltage 0-5V
bar

The lower limit of the measuring range (0 bar) is indicated by a voltage value of 0 V
while the upper limit (10 bar) correlates with 5 V. As a result, the fields must be
populated as follows:

NOTE
The maximum permissable input voltage is 5 V.

Input type Frequency A level meter with frequency output is installed in a 430 l tank.
Input type:
Unit:

Frequency
l

The maximum level of 430 l is indicated by a frequency of 6000 Hz. As a result, the
fields must be populated as follows:

The maximum permissable frequency is 6000 Hz. If the connected sensor
transmits higher frequencies, a frequency divider must be interconnected.

50

Programming the logger using the SebaDataView-3 software

Input type Pulse A flowmeter with a digital pulse output is connected to a channel of the logger.
The flowmeter transmits one pulse per 16 litres.
Input type:
Unit:

Pulse
l

The checkbox Fast-pulse-mode must be activated if a sensor is used with a
pulse rate >50 Hz (ie, more than 50 pulses per second). Otherwise, it may result in
inaccurate measurements.
Select whether the flow shall be measured per hour or per second.
If you want to compare your results to the values of a water meter, you have the chance
to enter the water meters’ counter reading into the respective field prior to the
measurement.

Determining the flow A flowmeter is connected to channel 3. In addition to the flow rate itself, the flow
direction direction shall be determined. For this purpose, a sensor which indicates the flow
direction by means of voltage values is connected to another channel of the logger (in
the figure Channel 2).
Input type:

Sign slave for other channel

First of all, it has to be specified which direction is indicated by the 5 V value. A voltage
value of 0 V automatically indicates the opposite direction.
Furthermore, the channel (flow), the determined flow direction applies to, has to be
selected (in this case Channel 3).

51

Programming the logger using the SebaDataView-3 software

6.4.2

Configuring alarm conditions (Threshold monitoring)
The device can trigger certain alarm actions when a value goes above or below defined
threshold values. The alarm thresholds must be defined individual for each
measurement channel.

Specify alarm targets In the Alarm destinations segment, you define what should happen in case of a
threshold violation.

Checkbox

Description

Relais 1

The internal relay 1 is switched.
As a result the device or warning unit is activated that is connected by
connecting cable VK76 (see page 28).
As a result a signal lamp can be switched on, for example, a pump
activated or a valve closed, etc.
The internal relais 2 will be switched.
An alert will be sent via e-mail to the stored destination addresses.
An alert will be sent by SMS to the stored phone numbers.
An un-scheduled measuring data upload will take place.
For one hour after the alarm, the logger is available over the cellular
network. In this period, a real-time measurement ("FTP step test") can
be performed with the device via the SebaKMT Cloud.

Relais 2
E-Mail
SMS
FTP
1h Standby

To save energy, the loggers are not permanently ready to receive
messages. Only when this box is checked it is ensured that the device
is available via the cellular network after an alarm and a real-time
measurement can be performed.
Note: There is a conflict of interest between the function "1h
standby" and the function "CSV upload" in the cellular network
settings.
This means: The alarm target "1h standby" only works if the
checkbox "CSV upload" is disabled in the cellular network
settings.
If the "CSV upload" box is checked, the alarm target "1h
standby" can be selected, but when an alarm occurs it does
not go into effect, meaning no real-time measurement can be
performed.

"Relais" as alarm If a maximum level is set, the activated relay will trigger a connected device to switch on
destination as soon as the max. level is exceeded. The device is switched off, as soon as the signal
falls back below the threshold. This process takes place vice versa for a minimum level.
The minimum and the maximum threshold cannot be assigned to different relays. If both
levels are set, each of the activated relays will switch as soon as one of the thresholds is
crossed, no matter which one.

52

Programming the logger using the SebaDataView-3 software

A relay cannot be assigned to more than one alarm. If a relay is already included in an
existing channel configuration, it cannot be used in combination with any other channel
or switching input.
Configuring Perform the following steps to configure the alarm thresholds:
alarm trigger
Step Description
1

In the segment Alarm Trigger – Settings specify whether there is a minimum
and / or a maximum threshold to be monitored by activating the respective
checkbox(es).

2

Enter the minimum and / or the maximum threshold into the respective field(s).
Input of negative values is possible.
(Example of temperature sensor: min. level: -15°C)
For flow sensors, the sign indicates the flow direction of the fluid.
(Example: 5 l/s corresponds to 5 l/s forward flow;
-5 l/s corresponds to 5 l/s reverse flow)

3

A hysteresis and a debounce value can be defined for alarm input preventing a
constant triggering of the alarm by measuring values fluctuating marginally
around the threshold.
Enter a Hysteresis value. The Hysteresis value in percent designates a
symmetrical range around the specified threshold the input signal can fluctuate in
without having an impact on the current alarm status.
Example: (pressure sensor)
Min. level: 2.0 bar
Hysteresis: 10 %
The alarm does not switch on until the input signal reaches 90 %
of the specified threshold (here 1.8 bar). After this, the alarm does not
switch off until the input signal exceeds 110 % of the threshold
(here 2.2 bar).
(continued on next page)

53

Programming the logger using the SebaDataView-3 software

Step Description
Select a Debounce value. The input signal must cross the specified threshold not
only one time in order to switch an alarm on or off, but two times more after
specific periods of time. These periods of time, called ‘debounce’, always are a
multiple of the specified logging interval.
Example: (pressure sensor)
Logging interval: 5 sec
Min. level: 2.0 bar
Debounce: 15 sec
The alarm does not switch on until the input signal crosses the specified
threshold (2.0 bar) three times in succession (15 seconds).
4

Select the days of the week alarming should be active on by marking the
respective checkbox(es).

Defining exceptions The segment Alarm Trigger – Exceptions offers the possibility to modify the alarm
setting, entered under Alarm Trigger - Settings, for specific periods of time (certain
days of the week or even periods of time in a day).
Example: The following picture shows a possible setting:

Here, from Monday to Friday an alarm is switched on as soon as the input signal
falls below a value of 2.0 bar (set in Alarm Trigger – Settings segment), but from
2 to 4 o’clock in the morning a threshold of 4.0 bar is valid (set in Alarm Trigger –
Exceptions segment).

54

Programming the logger using the SebaDataView-3 software

Minimum flow The Min. Flow Monitoring checkbox in the Alarm trigger - Exceptions segment is
monitoring only relevant in the context of flow measurements.
When the connected sensor is not a flow sensor, please disable this checkbox,
i.e. make sure it is unchecked.
When this checkbox is activated, the alarm case occurs when the specified minimum
flow IS NOT reached within the specified period.
More specifically: The alarm is triggered immediately after the end of the measurement if
the value never dropped below the "min. level" between "start time" and "end time".
Example: In your experience, the flow rate at the measuring point drops between
2 am and 4 am under the value of 2.0 l/s. An alarm should be triggered if the flow
rate does not fall below 2.0 l/s during the entire period.

Procedure:







Result:

6.4.3

tick the Min. Flow Monitoring checkbox
type the value 2.0 in the Min. level field
specify 2:00 as Start time of monitoring
specify 4:00 as End time of monitoring
tick the weekdays on which this monitoring alarm should apply
(here: Monday to Friday)

If the flow value drops below 2.0 l/s one or more times between 2 and 4 am,
no alarm is triggered.
If the flow value never drops below 2.0 l/s between 2 and 4 am, an alarm is
triggered.

Finishing the sensor configuration
Confirm and save the configuration of a channel by clicking the OK button.
Perform the configuration for the remaining channels.

6.5

Configuring the alarm inputs

Introduction Depending on its configuration a logger can be equipped with up to two switching inputs
(alarm inputs) which can be connected to active circuits. For each of these inputs it can
be specified which input voltage value causes an alarm.
As known from the channel configuration, an alarm can trigger up to two internal relays.
If your logger is equipped with a GSM modem, alarm messages can be sent via SMS
and / or e-mail. Furthermore, an unscheduled measuring data upload to your FTP server
can be performed in case of alarm. For that, GSM connectivity must be established and
properly configured.

55

Programming the logger using the SebaDataView-3 software

Activating an First of all, you have to activate the Alarm Inputs which are going to be part of an alarm
alarm input input during the upcoming operation period by marking the respective On/Off checkbox:

Configuring an After an alarm input has been activated, it must be specified which input voltage value
alarm input causes an alarm and which actions are triggered by an alarm.
Click the respective Configure button. The following window appears:

Proceed as follows to configure an alarm input:
Step Description
1

Specify the input voltage value which does, when present at the switching input,
trigger an alarm.
The input voltage threshold is 2.5 V. Any voltage value below 2.5 V is interpreted
as 0 V while voltages higher than 2.5 V are interpreted as 5 V. In order to ensure
a reliable classification, the actual voltage values should not be too close to 2.5 V.

2

Specify under Alarm Destinations which type of alarm message shall be sent
(SMS and / or e-mail and / or data upload to FTP server) and which
Internal Relay shall switch to trigger the connected device.

3

Confirm and save the settings by clicking the OK button.

A relay cannot be assigned to more than one alarm. If a relay is already included
in an existing channel configuration, it cannot be used in combination with any
other channel or switching input.

56

Programming the logger using the SebaDataView-3 software

6.6

Configuring the mobile communication

Introduction If your logger is equipped with an internal GSM modem, data transfer and alarm
messaging via mobile radio can be realised. For this purpose, a UMTS-enabled SIM
card (data contract) is required which can be obtained from almost any local mobile
network operator.
Usually, all the data required to set up mobile data transfer is provided within the
mobile network contract. Further information can be obtained from the website or
the hotline of the mobile network operator. If necessary, request guidance for
setting up data communication in particular. SebaKMT cannot provide any
specific technical advice in this case.

Procedure For mobile communication a number of settings must be made. Proceed as follows:
Step Description
1

Make sure the logger has been properly prepared for GSM connectivity (see
page 21).

2

In the Communication segment of the window, tick the GSM active checkbox.

3

Click the Configure GSM button.
Result: The GSM configuration dialogue appears.

4

Enter all the requested data. (You find more information about the configuration
dialogue below in the text).

5

Click Test to perform a GSM test. This test checks the existence and quality of
the cellular connection. (You find more information about testing the GSM
connection below in the text).

6

Confirm and save the settings by clicking the OK button.

57

Programming the logger using the SebaDataView-3 software

6.6.1

Explanations about the GSM configuration dialogue
The picture shows the GSM configuration dialogue:

You find explanations on the individual segments of the configuration dialogue in the
following table:
Segment

Parameter

SIM Card Settings

Enter the PIN code of the SIM card which is being used in the
device (see mobile communication contract or ask your provider).

FTP transfer

If you want the logged data to be transferred to a FTP server
daily, select the Active checkbox.
Daily upload time
Here you can specify at what time the measurement should be
sent to the FTP server daily ("upload"). Select a time from the
drop-down list.
Each upload includes the newly recorded measured data since
the previous upload.
If you wish a second measuring data upload every day, tick the
2nd upload checkbox and select the desired time for this second
upload from the second drop-down menu.
Send Event List
If you select the send Event List checkbox, simultaneously with
the measuring data upload another file is sent to the FTP server
containing an overview about the alarm events and GSM
connection establishments of the device. These information can
then be added to the device’s ‘event list’ (see page 74).
In total, 100 entries are possible, then the oldest entries are
removed from the list and replaced with the new entries.

58

Programming the logger using the SebaDataView-3 software

Segment

Parameter
CSV Upload
When you check this box, the recorded measured data is
uploaded to the FTP server in CSV format.
Explanation: Data in CSV format can be further processed, for
example with SCADA systems.
The upload does not take place at certain times, rather it is
performed in regular data packets.
A drop-down list appears. Select there how many measurement
data points each CSV data packet should include.
The daily standard upload of the measured data is not influenced
by the CSV upload. It is performed without any change. The
measured data are then in fact stored on the FTP server twice,
once in the standard data format for all SebaKMT applications
and once in CSV format.
Requirement: Uploading the measured data in CSV format is only
possible when the device is connected to a working external
power supply.
FTP Step Test
If the pending measurement should be a Step-Test measurement,
check this box.
Explanation: Immediately after receiving the configuration data,
the device starts recording data. This is forwarded directly to the
FTP server so that the progress of the measurement can be
followed via the internet in real time.
If the device is connected to an external power supply, the steptest measurement continues to run until it is stopped by the user.
Without an external power supply, the step-test measurement is
automatically stopped after 6 hours.

NOTE




Due to system constraints, the two options
FTP Step Test and CSV Upload cannot be
used simultaneously.
The step-test measurement places a significant
load on the battery, unless the device is
connected to an external power supply.

Configurable via FTP
When you check this box, with each measured data upload the
logger checks whether new configuration data is stored on the
FTP server. If this is the case, the data is downloaded onto the
logger and the device reprograms itself using this data.
SMS checkbox
and
E-Mail checkbox

If you want to receive notifications (regular status messages
and/or alarm messages) by SMS, activate the SMS checkbox.
If you want to receive notifications (regular status messages
and/or alarm messages) by e-mail, activate the E-mail checkbox.
(continued on next page)

59

Programming the logger using the SebaDataView-3 software

Segment

Parameter
Use the radio buttons to select, which messages you want to
receive:
 Alarm only
You will only receive alarm messages
(An alarm message contains the ID and comment of the sending
device, the date and time it is sent, the number of the corresponding
measurement channel, the reason for the alarm and the alarm
value)


Status daily
You receive alarm messages and a status message
once a day
(A status message contains the ID and comment of the sending
device, the date and time it is sent, the highest and lowest
measurement of each active measurement channel since the last
status message, flow quantity since the last status message (only for
flow sensors))



Status weekly
You receive alarm messages and a status message
once a week

Furthermore, specify the point in time and, if required, the day of
the week, the status message shall be sent. (Time values are
specified in 24-hour format.)
SMS Destination

Specify up to three mobile phone numbers here to which
summary or alarm messages should be sent.

E-mail Destination

Specify up to two e-mail addresses here to which summary or
alarm messages should be sent.

FTP Settings

Enter the access data for the FTP server to which the measuring
data will be sent . You received the data when you concluded the
FTP use contract or it can be requested from the operator of the
FTP server.
The device supports encrypted data transfer to FTPS servers.
Select the desired Encryption from the drop-down list.
Ensure that the right port is specified in the FTP settings.
When using encryption, it may be necessary to modify the
value.
The FTP server must support the selected encryption and
it must be set up accordingly by the administrator.

If you have already stored the access data for your FTP server in
the SebaDataView-3 database (see page 44) and want to use this
server, tick the Use own server checkbox. The access data are
then filled in automatically.
If you want to use the demo FTP server run by SebaKMT, tick the
Seba Demo Mode checkbox . The FTP access data are filled in
automatically. The logged measuring data will be transferred to
this server. However, the Seba Demo Server is for demonstration
purposes only!

60

Programming the logger using the SebaDataView-3 software

Segment

Parameter

Internet Settings

Here the data for access the internet must be entered.
Open the Provider drop-down list and select your cellular network
provider. The access data is then entered automatically.
If your cellular network provider is not included in the list, enter the
data manually. You can find the necessary information in the
material included with your cellular network contract. Otherwise,
please ask your cellular network provider.

E-mail Settings

If you want to receive messages via e-mail, enter the access data
for the e-mail account from which alarm or status messages are to
be sent. (Usually, this kind of information can be obtained from the
‘How to configure an e-mail client’ tutorial on the providers’
website. Username and password can be specified during the
account setup procedure or can be requested from the operator of
the mail account or from your system administrator. SebaKMT
does not provide e-mail accounts.)
The device supports encrypted e-mail transmission (TLS/SSL) via
an SMTPS e-mail account.
If you want to use encryption, check the Use TLS/SSL box.
Ensure that the right port is specified in the e-mail
settings. When using encryption, it may be necessary to
modify the value.
The e-mail server must support the selected encryption
and be configured accordingly.

If you have already stored the access data for your e-mail account
in the SebaDataView-3 database (see page 44) and want to use
this account, tick the Use own server checkbox. The access data
are then filled in automatically.
If you want to use a demo e-mail account run by SebaKMT, tick
the Seba Demo Mode checkbox. The respective data are filled in
automatically. However, the Seba Demo Account is for
demonstration purposes only!

6.6.2

Testing the mobile connection ('GSM test')
With a 'GSM test' you can check whether the cellular network connection works with the
parameters entered.

Requirements In order to perform a GSM test, the following requirements must be met:
 the GSM configuration must have been already finished (see previous sections),
 a radio interface has to be connected to the computer (e.g. Log RI),
 the logger has to be switched on
 the logger must be within the computer’s wireless range

61

Programming the logger using the SebaDataView-3 software

Procedure Proceed as follows to carry out a GSM test:
Step Description
1

In the SDV-3 software open the GSM configuration dialogue of the respective
device (see previous sections).
(select the logger in the directrory tree >> click on Program >> click on
Configure GSM)

2

On the upper right of the window, click on the Test button.
Result: The device dials into the mobile network. It sends a test SMS or e-mail
respectively. Furthermore, it tries to create a test file in the target folder of your
FTP server.

Test FTP file If the transmission has been successfully completed, you find a test file with the name
“ftp-test.txt” on your FTP server. It contains date and time of the test.
Test SMS / e-mail All addressees should receive a SMS or e-mail containing the following information:
 Type of device and identification number
 Date and time of the test
 Signal quality
In the case of bad signal quality , it may help to move the GSM antenna in a better
position.
Debugging If no file is created in the folder of the FTP server or no SMS / e-mail has been received,
the test failed. Then, use the Event list button to retrieve the event list (see page 74)
from the device. There, information can be found which can help to identify the problem.

6.7

Adjusting the start time of data recording
The point in time, the device shall start logging, has to be defined under Record.
Use the controls to specify a start date and time or click on the Current time button to
get the system date and time of the computer filled in.
If the entered recording start lies in the past, seen from the point in time the device is
receiving the configuration data, the device starts data storage immediately.

6.8

Activate / deactivate circular buffer
In the Memory mode segment you can specify whether measurement data is stored
using the circular buffer method.
If you disable the Ring memory checkbox, the measurement is stopped as soon as the
logger memory is full.
If you enable the Ring memory checkbox, the logger memory capacity is set to
"infinite". This means that the measurement is continued even after the storage limit is
reached. The oldest measurements are then overwritten by new measurements.
The ring memory setting is recommended in principle for all loggers with an internal
GSM modem and for loggers that will be used over the long term at the same location.

62

Programming the logger using the SebaDataView-3 software

6.9

Adding a comment
In the Comment segment you have the opportunity to provide information about this
device or the location of the device, etc.

6.10

Sending the configuration data to the logger
Finally, the data must be transferred to the logger.

NOTE
Keep in mind that the data memory of the logger is reset by programming,
i.e. all measurement data is deleted.

Data transfer To send the data wirelessly to the logger, click the bottom of the window on Program.
via radio The logger must be switched on and within the wireless operating range of the
computer.
The new configuration data is sent to the logger and installed there immediately. A
success message appears on the computer screen.
Data transfer If you are remotely programming the logger, click the bottom of the window on
via FTP server Write settings. The access data to the FTP server must be stored in the system
settings of the SDV-3 software (see page 44).
The new configuration data is upload to the FTP server. From there, it is downloaded by
the logger at the next planned contact and installed immediately.

63

Programming the logger using the SebaDataView-3 software

64

Retrieving and evaluating data

7

Retrieving and evaluating data

7.1

‘Realtime Measurement’ with SDV-3 software
Using the real-time measurement function of the SebaDataView-3 software you have
the chance to carry out a measurement and observe the data recording in real-time.
Also a current measurement can be observed.

Requirements The following requirements must be met:
 computer with SebaDataView-3 software
 a radio interface must be connected to the computer (e.g. Log RI)
 the logger must be switched on
 the device must be within the computer’s wireless range
Procedure Proceed as follows to retrieve and display live data:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Realtime measurement.

3

From the context menu select if the ‘live’ measuring values should be displayed
graphically or numerically.
If you select Digital, the measured value of each active channel is displayed
numerically in a table.
If you select Graph, the measured data of the active channels is shown as the
curves of a graph:

The continuous curves in the top diagram show the last 10 taken values.
The bottom diagram shows the entire realtime measurement:
Result: If a measurement already is in process, the values of this recording are
displayed. Otherwise, a new measurement is started and the taken ‘live’ data is
shown.
You finish the realtime measurement function using the Stop button or by closing the
display window.
Storing the data set After having closed the graphical view, a dialogue appears asking if you’d like to store
the data set of this realtime measurement. If you answer with Yes, the measuring data
is stored in the software database and can from now on be found in the data records list
(see page 67).

65

Retrieving and evaluating data

7.2

Retrieving measurement data
The measuring data is stored in the memory of the device. It can be read out via short
range radio using the computer.
If measuring data have been transmitted from the device via mobile radio to a FTP
server, it can be downloaded from there to your computer. In addition, it is possible to
access this data in the SebaKMT Cloud "online" and to further process it.

7.2.1

Reading out data using the PC/Laptop
You can read out the measuring data from the device using your computer with
SebaDataView-3 software.

Requirements The following requirements must be met:
 computer with SebaDataView-3 software
 a radio interface must be connected to the computer (e.g. Log RI)
 the logger must be switched on
 the device must be within the computer’s wireless range
Procedure Proceed as follows:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Read.

3

Select RF from the appearing context menu.
Result: The connection between the computer and the device is established and
the data readout starts. In a small window the progress of the data transfer is
displayed.
As soon as the transfer is completed, a new window opens and the measuring
data is displayed (see page 68).

7.2.2

Downloading data from a FTP server
Depending on the device's configuration the measuring data may have been transmitted
to a FTP server. From there it can be downloaded to your computer.

Requirements The following requirements must be met:
 computer with SebaDataView-3 software and Internet access
 the FTP access data must have been entered and stored in the database of the
software (see page 44)
Procedure Proceed as follows to download data from the FTP server:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Read.

3

Select FTP from the appearing context menu.
Result: The download starts. In a small window the progress of the data transfer
is displayed.

66

Retrieving and evaluating data

Step Description
4

As soon as the download is finished, click the OK button.
Result: The small window closes. Measuring data and event list data of the
respective device are now available in the software database and can be
displayed.

7.3

Managing saved measurement data
In the database of the software, a large number of measurement data records can be
saved for each device.
You can display all measurement data records of a device in a list. Proceed as follows:
Step Description
1

Select the relevant device in the directory tree of the SDV-3 software.

2

In the menu bar, click on Show data.
Result: A new window opens. It shows a table where all measurement data
records of the device are listed (see figure).
If only one measurement data record is saved for the device, this window does
not appear. Instead, the measurement data display opens immediately (see
page 68).

Data records list The window contains a table in which all measurement data records saved for this
device in the database of the software are listed. These are results from standard
measurements as well as recordings of real-time measurements.

Functions Using the buttons at the bottom of the window, you can call up and manage the
individual measurement data records.
Select the relevant line in the list and click the desired button:
Show

… The measurement data is shown.
(Alternatively, you can simply double-click the respective line in the
table.)

Edit

… A window that can be used to edit the comment text for this
measurement opens.

Delete … The data record is deleted from the database of the software. Answer
the confirmation prompt with Yes.
Export … The data record can be exported and stored in CSV format to the
hard disk or any other memory. The saved file can be accessed using
any CSV-capable application (e.g. Microsoft Excel).

67

Retrieving and evaluating data

7.4

Displaying measurement data

7.4.1

Calling up a measurement

Calling up the most To call up the most recently saved measurement data of a device, double-click this
recent measurement device in the directory tree of the software. The window for displaying the measurement
data opens (see below).
Calling up a particular To call up the results of a particular measurement, proceed as follows:
measurement
Step Description
1

Select the relevant device in the directory tree.

2

In the menu bar, click on Show data.
Result: The data records list opens (see page 67).
If only one measurement data record is saved for this device, this list does not
appear. Instead, the measurement data display opens immediately.

3

Select the required data record in the list and click Show or double-click the
concerning line.
Result: The measurement data is shown.

7.4.2

Using the measurement data display

Design The following figure shows the window for displaying measurement data:

In the top diagram the entire measurement is displayed. Up to four different coloured
curves can be seen. Each curve is representing the results of one of the device's
measuring channels.
The bottom diagram is used for viewing enlarged subareas of the measurement curves
(see below).
The X-axis corresponds to the chronological sequence of a measurement. The Y-axis
corresponds to the measured values.
Selecting a channel To focus on the data of one measuring channel you can either select the channel from
the blue info window on the right or click directly on the respective curve in the bottom
diagram.

68

Retrieving and evaluating data

The curve is shifted to the foreground. If there are alarm thresholds set for this channel,
they are indicated by horizontal black lines.
If the curve represents a pressure measurement, all recorded pressure surges are
indicated by vertical black lines.
Some important characteristics of the measurement are displayed in the blue window.
The information relate exclusively to the section of the measurement that is currently
displayed in the bottom diagram.
Click anywhere in the diagram to end focusing on one individual channel.
Specifying the You have the following options for displaying an enlarged subarea of the overall
zoom area measurement curve:
 Free selection of a section of the curve
Select the desired area of the measurement in the top diagram. To do this, click
inside the diagram, hold down the left mouse button and guide the cursor diagonally
across the relevant area. The selected area will be displayed in the bottom diagram.
If you click the coloured area that was selected and hold down the left mouse
button, you can freely move the selection within the top diagram. This function is
practical for use as a “magnifying glass”.
 Selecting time frames from the list
Using the drop-down list on the right next to the diagram, you can restrict the time
frame of the displayed area to a month, a week, a day or an hour. By means of the
"User-defined" option you have the the chance to specify the start and end time of
the span to be displayed.
Moving in the diagram Using the mouse wheel (if available), you can move within the diagram along the axes:
 Mouse wheel … Movement along the X-axis
 Shift key + mouse wheel … Movement along the Y-axis
Other functions A context menu opens after you right-click in the diagram view. A number of other
functions for working with the diagram are available here:
Function

Description

Zoom in

You can use this function to select an area in the diagram for enlarged
display.
The cursor symbol switches from to
. Left-click in the diagram,
hold down the button and guide the cursor to the desired area.

Pan

You can use this function to grab and move the displayed
measurement area.
The cursor symbol switches from to
. Left-click in the diagram,
hold down the button and freely move the image section in all
directions.

Select

Use this command to end the functions Zoom in and Pan.

Measure

You can use this function to display the time span and pressure
difference between any two points on the displayed measurement
curve.
Left-click in the diagram on the desired starting point, hold down the
button and guide the cursor to the desired ending point. The time span
between the two points is displayed.
(continued on next page)

69

Retrieving and evaluating data

Function

Description

Insert label

You can use this function to create text fields (labels) within the
diagram. These fields can be used to add comments to any points in
the diagram. Labels remain saved after the diagram display is closed.
Edit text

… Double-click the text field – input text – then click
once outside of the field

Move label

… Click the text field once – then “grab onto it” (click it
and hold down the left mouse button) and move it
wherever you would like

Delete label … Click the text field once – then press the “Delete” key
on your keyboard
Hide / Show
grid

You can use this option to decide whether there should be a grid shown
in the bottom diagram’s background or not.

Print If you want to print the actual diagram view, right-click in the bottom diagram and select
Print from the appearing context menu.
Reset initial view If you want to cancel all active functions in the window and return to the initial diagram
view, right-click in the bottom diagram and select Reset from the appearing context
menu.

7.4.3

Displaying pressure surges
If pressure surges were recorded in addition to the standard pressure measurement,
you will see a drop-down list at the very top of the displayed window. All recorded
pressure surges are in this list.
In order to display the one-minute recording of an individual pressure fluctuation, click
the desired recording time point in this list. The corresponding measurement curve will
be displayed in the bottom diagram.

With the tools described above, you can view the recording in detail and carry out a
closer analysis.
To return to the standard measurement display, click Overview in the drop-down list.

70

Retrieving and evaluating data

7.5

Exporting data in CSV format
The data collected from a device and stored in the SDV-3 database can be exported in
CSV (‘Comma Separated Values’) format. In doing so a file containing all logged valuetime pairs line by line is saved to the hard disk or any other memory. The saved file can
be accessed using any CSV-capable application (e.g. Microsoft Excel).

Export all data records To export all the stored measurement data of one device, proceed as follows:
Step Description
1

Select the device whose data you want to export in the directory tree.

2

In the menu bar, in the segment Measurement data click on Export.
Result: An Explorer window opens.

3

Browse to the desired target folder and save the data set there.

Export one data record To export the data of one individual measurement, proceed as follows:
Step Description
1

Select the device whose data you want to export in the directory tree.

2

In the menu bar, in the segment Measurement data click on Show data.
Result: A new window shows all measurement data records saved for this device.

3

Select the relevant data record and click on Export.
Result: An Explorer window opens.

4

Browse to the desired target folder and save the data record there.

71

Retrieving and evaluating data

72

Miscellaneous functions of the SebaDataView-3 software

8

Miscellaneous functions of the SebaDataView-3 software

8.1

Find out status information of a device
Every time data is exchanged between the device and the computer, general
information on the status of the device is also transferred to the computer.
Status information include, for example: :
 The device firmware version
 Internal date and time of the device
 Battery status
 Free memory capacity, etc.

Procedure To view the status information of a device, proceed as follows:
Step Description
1

Select the relevant device in the directory tree.

2

In the menu bar, click on Program.
Result: The window for programming opens.
The status information can be found in the State segment.

The data refer to the time of the last data exchange between device and
computer.
If you wish more current information, read the configuration of the device (next
step). For that, the following requirements must be met:
 a radio interface must be connected to the computer (e.g. Log RI)
 the device must be registered in the SDV-3
 the device must be switched on
 the device must be within the computer’s wireless range
3

Click on Read.
Result: The current configuration data is transferred from the device to the
computer. The information on the screen is updated.

Explanations In the Date/time line, the internal time of the logger is displayed. Each time data is
exchanged, the time of the logger is synchronised with the system time of the computer.
After reading out the configuration (see Step 3), the displayed time should match the
actual time.
The Resulting storage periode line indicates how long the device can continue to
measure with the currently set parameters until the device memory is full.

73

Miscellaneous functions of the SebaDataView-3 software

8.2

Receiving an ‘Event List’

Introduction By the help of the Event List function you get information about
 a device's alarm events up to now,
 a device's GSM connection establishments up to now.
These events are listed in a table on the screen.

If measuring data have been sent from the device to a FTP server, the event list is part
of these data and is available right after the download.
For energy saving reasons, the event list is not part of the data transferred to the
computer via radio. In this case, the event list still needs to be retrieved from the logger,
before it can be displayed on the screen.
A maximum of 600 events can be listed. After 600 entries have been reached, the
respective oldest values are overwritten.
Procedure Proceed as follows to call the event list of a device:
Step Description
1

Select the relevant device in the directory tree.

2

In the menu bar in the segment Event list click on Show.
Result: The event list window opens. The events up to the time of the last data
readout are shown.
If the list is empty, there are no events stored for this device in the software
database. Maybe the list has not yet been read out from the device.
If you wish more current information, read the event data from the device now
(next step). For that, the following requirements must be met:
 a radio interface must be connected to the computer (e.g. Log RI)
 the device must be registered in the SDV-3
 the device must be switched on
 the device must be within the computer’s wireless range

3

Click the Read button.
Result: The latest event data are transmitted from the device to the computer and
added to the Event list on the screen. If the list still is empty, no events have been
stored by the device.

Deleting events You can remove events from the list and delete them in the software database by
selecting them in the window and clicking the Delete button.

74

Firmware update

9

Firmware update
We recommend that you keep the firmware the device current at all times. SebaKMT
makes improved versions of the firmware available in the download area of
www.sebakmt.com on a regular basis.

FW version in use The firmware version currently used by the device can be found in the status information
of the device (see page 73).
Saving measuring data All data stored in the device’s internal memory may be deleted by the firmware update.
Therefore, retrieve all data from the device before carrying out an update.
Requirements To conduct a firmware update, the following requirements must be met:
 computer with SebaDataView-3 software Internet access
 a radio interface must be connected to the computer (e.g. Log RI)
 the relevant device must be registered in the SDV-3 software
 the logger must be switched on
 the device must be within the computer’s wireless range
Procedure To update the firmware of one or more devices, proceed as follows:
Step Description
1

Download the file for the update from the download area of www.sebakmt.com
onto your computer.

2

Open the SebaDataView-3 software.

3

Click the water drop symbol
on the top left of the window and select the
option Firmware Update in the window that opens.
Result: The following window opens.

List of the devices
that were updated

List of the devices
that are to be
updated

4

In the drop-down list in the top left, select the type of device LogD3.

5

At the top of the list on the left, click the folder symbol
.
A new input field opens. There, enter the identification number (ID) of the device
you want to update and confirm with the ENTER key on your keyboard. The ID
now appears in the list on the left.
Several devices can be updated at the same time, provided they are of the same
type. If you want to do that, enter the IDs of the relevant devices now.
If you want to remove a device from the list, select the relevant ID and click the
‘Delete’ symbol

at the top of the list.
(continued on next page)

75

Firmware update

Step Description
6

In the Update file segment on the lower left of the window, enter the location
where you saved the update file that you downloaded to your computer in step 1.
To do this, click the folder symbol

7

and use the Explorer window that opens.

Click OK to start the firmware update.
Result: The update file is transferred to the device/s and installed there. A bar
under the list on the right shows the progress of this process. After the file is
installed, each device restarts automatically. The IDs of the successfully updated
devices switch from the left to the right side on the screen. As soon as the
firmware update is successfully completed for all devices, a corresponding
message appears in the update window.

76

Changing the battery

10

Changing the battery

10.1

Ordering a battery-replacement kit
Used batteries can be replaced. You will need a special battery replacement kit, which is
available from SebaKMT.

Get a battery Compare the first 8 digits of the type key on the logger's nameplate with the information
replacement kit in the following tables. Select the appropriate battery-replacement kit and state the item
number when ordering.
Battery-replacement kits for devices with internal GSM modem:
Type key of the device

Item number of the battery-replacement kit

LOG D-3 4 G

90016461

LOG D-3 2 G

90016464

Battery-replacement kits for devices without GSM modem:
Type key of the device

Item number of the battery-replacement kit

LOG D-3 4

90016463

LOG D-3 2

90016466

If you are not sure which kit to choose, please contact your SebaKMT service partner or
contact us. Contact information on our web site www.sebakmt.com.
Spare seal rings Each replacement kit contains new O-ring seals for the logger housing and the logger lid
supplied in addition to the batteries. Replacing the seals in the course of the battery change is
mandatory.Otherwise, the tightness of the device is compromised.

10.2

Conduct the replacement

Back up data Stored measurement data may get lost due to the battery change. Therefore, it is
recommended to read and save the logger's measurement data to the computer prior to
the battery replacement.
Replace batteries To conduct the battery change, proceed as follows.

NOTE
Please be careful not to damage any parts. Don't use any force.

Step Description
1

The device needs to be turned off.

2

Loosen the six screws of the device.

3

Loosen and remove the lid of the device. Do not use any tools as an aid, even
not if the lid seems to be stuck.
Result: Inside the device you have access to the batteries.
(continued on the next page)

77

Changing the battery

Step Description
Loggers with internal GSM modem have two batteries. Loggers without
GSM modem have only one battery.
In the middle of the device there is a connection socket with two superimposed
jacks. Each battery is connected to one of these jacks.

4

Disconnect the batteries.
Note:
The battery plug is scurely held in the socket by two small locking catches.
Therefore, the plug must not be pulled straight backwards out of the jack. This
could lead to damage.
To disconnect:
1. Slightly press with your finger from above onto the plug.
2. At the same time, carefully pull the two wires to the back and down.
Do not use force.

5

Pull the battery out of the compartment.

6

Insert the new battery. Make sure that the wires of the battery are in the recess of
the compartment and not be jammed.

7

Connect the battery, i.e. put the plug into one of the two jacks in the middle of the
device, no matter which one. You must feel the plug latch in.

8

Replace the two rubber seal rings of the logger.
For that:
1. Remove the old ring from the logger's housing and replace it with the new
ring of the same size (Art.Nr. 90013554) from the battery replacement kit.
Make sure that the ring fits properly and tightly to the housing.
2. Remove the old ring from the logger's lid and replace it with the new ring of
the same size (Art.Nr. 90013552) from the battery replacement kit. Make
sure that the ring fits properly.

78

Changing the battery

Step Description
9

Attach the lid to the housing again.
The rubber seal inside the lid may possibly fall out. Therefore, when
re-assembling the device, it may be helpful not to put the lid on the
housing but to take both parts upside down and then put the housing on
the lid.
Observe the following points:
 The rubber seals and the surfaces of housing and lid which touch each other
must be free of dirt.
 Ensure that the wires will not be pinched or clamped.
 Be careful not to jam the housing parts against each other.
 Tighten the screws in a crosswise sequence.
 Tighten the screws finger-tight (1 Nm). Do not overtighten!

10.3

Reset of the battery counter
After a battery replacement has taken place, the internal 'battery counter' of the device
must be reset. Otherwise, the actual battery level cannot be recognized by the logger
and stated in the SDV-3 properly.

Requirements The following requirements must be met:
 computer with SebaDataView-3 Software
 a wireless interface must be connected to the computer (e.g. Log RI)
 the logger must be registered to the SebaDataView-3
Procedure Proceed as follows:
Step Description
1

The logger needs to be turned on.

2

Open the SDV-3 software.

3

In the directory tree, right-click on the relevant logger.

4

In the context menu, select the Reset battery counter option.

5

Confirm the message on the screen with OK.
Result: The command is sent to the logger and executed. Subsequently, a
success message appears on the screen.

79

Changing the battery

80

Changing the battery

Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi
podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující
se na likvidaci starých elektrických spotřebičů v blízkosti svého působiště.
Dit symbool duidt aan dat het product met dit symbool niet verwijderd mag worden als gewoon huishoudelijk afval. Dit is een product voor industrieel gebruik, wat betekent
dat het ook niet afgeleverd mag worden aan afvalcentra voor huishoudelijk afval. Als u dit product wilt verwijderen, gelieve dit op de juiste manier te doen en het naar een
nabij gelegen organisatie te brengen gespecialiseerd in de verwijdering van oud elektrisch materiaal.
This symbol indicates that the product which is marked in this way should not be disposed of as normal household waste. As it is a B2B product, it may also not be disposed
of at civic disposal centres. If you wish to dispose of this product, please do so properly by taking it to an organisation specialising in the disposal of old electrical equipment
near you.
Този знак означава, че продуктът, обозначен по този начин, не трябва да се изхвърля като битов отпадък. Тъй като е B2B продукт, не бива да се изхърля и в
градски пунктове за отпадъци. Ако желаете да извърлите продукта, го занесете в пункт, специализиран в изхвърлянето на старо електрическо оборудване.
Dette symbol viser, at det produkt, der er markeret på denne måde, ikke må kasseres som almindeligt husholdningsaffald. Eftersom det er et B2B produkt, må det heller ikke
bortskaffes på offentlige genbrugsstationer. Skal dette produkt kasseres, skal det gøres ordentligt ved at bringe det til en nærliggende organisation, der er specialiseret i at
bortskaffe gammelt el-udstyr.
Sellise sümboliga tähistatud toodet ei tohi käidelda tavalise olmejäätmena. Kuna tegemist on B2B-klassi kuuluva tootega, siis ei tohi seda viia kohalikku jäätmekäitluspunkti.
Kui soovite selle toote ära visata, siis viige see lähimasse vanade elektriseadmete käitlemisele spetsialiseerunud ettevõttesse.
Tällä merkinnällä ilmoitetaan, että kyseisellä merkinnällä varustettua tuotetta ei saa hävittää tavallisen kotitalousjätteen seassa. Koska kyseessä on yritysten välisen kaupan
tuote, sitä ei saa myöskään viedä kuluttajien käyttöön tarkoitettuihin keräyspisteisiin. Jos haluatte hävittää tämän tuotteen, ottakaa yhteys lähimpään vanhojen
sähkölaitteiden hävittämiseen erikoistuneeseen organisaatioon.
Ce symbole indique que le produit sur lequel il figure ne peut pas être éliminé comme un déchet ménager ordinaire. Comme il s’agit d’un produit B2B, il ne peut pas non plus
être déposé dans une déchetterie municipale. Pour éliminer ce produit, amenez-le à l’organisation spécialisée dans l’élimination d’anciens équipements électriques la plus
proche de chez vous.
Cuireann an siombail seo in iúl nár cheart an táirgeadh atá marcáilte sa tslí seo a dhiúscairt sa chóras fuíoll teaghlaigh. Os rud é gur táirgeadh ghnó le gnó (B2B) é, ní féidir
é a dhiúscairt ach oiread in ionaid dhiúscartha phobail. Más mian leat an táirgeadh seo a dhiúscairt, déan é a thógáil ag eagraíocht gar duit a sainfheidhmíonn i ndiúscairt
sean-fhearas leictrigh.
Dieses Symbol zeigt an, dass das damit gekennzeichnete Produkt nicht als normaler Haushaltsabfall entsorgt werden soll. Da es sich um ein B2B-Gerät handelt, darf es
auch nicht bei kommunalen Wertstoffhöfen abgegeben werden. Wenn Sie dieses Gerät entsorgen möchten, bringen Sie es bitte sach gemäß zu einem Entsorger für
Elektroaltgeräte in Ihrer Nähe.
Αυτό το σύμβολο υποδεικνύει ότι το προϊόν που φέρει τη σήμανση αυτή δεν πρέπει να απορρίπτεται μαζί με τα οικιακά απορρίματα. Καθώς πρόκειται για προϊόν B2B, δεν
πρέπει να απορρίπτεται σε δημοτικά σημεία απόρριψης. Εάν θέλετε να απορρίψετε το προϊόν αυτό, παρακαλούμε όπως να το παραδώσετε σε μία υπηρεσία συλλογής
ηλεκτρικού εξοπλισμού της περιοχής σας.
Ez a jelzés azt jelenti, hogy az ilyen jelzéssel ellátott terméket tilos a háztartási hulladékokkal együtt kidobni. Mivel ez vállalati felhasználású termék, tilos a lakosság
számára fenntartott hulladékgyűjtőkbe dobni.Ha a terméket ki szeretné dobni, akkor vigye azt el a lakóhelyéhez közel működő, elhasznált elektromos berendezések
begyűjtésével foglalkozó hulladékkezelő központhoz.
Questo simbolo indica che il prodotto non deve essere smaltito come un normale rifiuto domestico. In quanto prodotto B2B, può anche non essere smaltito in centri di
smaltimento cittadino. Se si desidera smaltire il prodotto, consegnarlo a un organismo specializzato in smaltimento di apparecchiature elettriche vecchie.
Šī zīme norāda, ka iztrādājumu, uz kura tā atrodas, nedrīkst izmest kopā ar parastiem mājsaimniecības atkritumiem. Tā kā tas ir izstrādājums, ko cits citam pārdod un lieto
tikai uzņēmumi, tad to nedrīkst arī izmest atkritumos tādās izgāztuvēs un atkritumu savāktuvēs, kas paredzētas vietējiem iedzīvotājiem. Ja būs vajadzīgs šo i zstrādājumu
izmest atkritumos, tad rīkojieties pēc noteikumiem un nogādājiet to tuvākajā vietā, kur īpaši nodarbojas ar vecu elektrisku ierīču savākšanu.
Šis simbolis rodo, kad juo paženklinto gaminio negalima išmesti kaip paprastų buitinių atliekų. Kadangi tai B2B (verslas verslui) produktas, jo negalima atiduoti ir buitinių
atliekų tvarkymo įmonėms. Jei norite išmesti šį gaminį, atlikite tai tinkamai, atiduodami jį arti jūsų esančiai specializuotai senos elektrinės įrangos utilizavimo organizacijai.
Dan is-simbolu jindika li l-prodott li huwa mmarkat b’dan il-mod m’għandux jintrema bħal skart normali tad-djar. Minħabba li huwa prodott B2B , ma jistax jintrema wkoll
f’ċentri ċiviċi għar-rimi ta’ l-iskart. Jekk tkun tixtieq tarmi dan il-prodott, jekk jogħġbok għamel dan kif suppost billi tieħdu għand organizzazzjoni fil-qrib li tispeċjalizza fir-rimi ta’
tagħmir qadim ta’ l-elettriku.
Dette symbolet indikerer at produktet som er merket på denne måten ikke skal kastes som vanlig husholdningsavfall. Siden dette er et bedriftsprodukt, kan det heller ikke
kastes ved en vanlig miljøstasjon. Hvis du ønsker å kaste dette produktet, er den riktige måten å gi det til en organisasjon i nærheten som spesialiserer seg på kassering av
gammelt elektrisk utstyr.
Ten symbol oznacza, że produktu nim opatrzonego nie należy usuwać z typowymi odpadami z gospodarstwa domowego. Jest to produkt typu B2B, nie należy go więc
przekazywać na komunalne składowiska odpadów. Aby we właściwy sposób usunąć ten produkt, należy przekazać go do najbliższej placówki specjalizującej się w
usuwaniu starych urządzeń elektrycznych.
Este símbolo indica que o produto com esta marcação não deve ser deitado fora juntamente com o lixo doméstico normal. Como se trata de um produto B2B, também não
pode ser deitado fora em centros cívicos de recolha de lixo. Se quiser desfazer-se deste produto, faça-o correctamente entregando-o a uma organização especializada na
eliminação de equipamento eléctrico antigo, próxima de si.
Acest simbol indică faptul că produsul marcat în acest fel nu trebuie aruncat ca şi un gunoi menajer obişnuit. Deoarece acesta este un produs B2B, el nu trebuie aruncat nici
la centrele de colectare urbane. Dacă vreţi să aruncaţi acest produs, vă rugăm s-o faceţi într-un mod adecvat, ducând-ul la cea mai apropiată firmă specializată în colectarea
echipamentelor electrice uzate.
Tento symbol znamená, že takto označený výrobok sa nesmie likvidovať ako bežný komunálny odpad.Keďže sa jedná o výrobok triedy B2B, nesmie sa likvidovať ani na
mestských skládkach odpadu. Ak chcete tento výrobok likvidovať, odneste ho do najbližšej organizácie, ktorá sa špecializuje na likvidáciu starých elektrických zariadení.
Ta simbol pomeni, da izdelka, ki je z njim označen, ne smete zavreči kot običajne gospodinjske odpadke. Ker je to izdelek, namenjen za druge proizvajalce, ga ni dovoljeno
odlagati v centrih za civilno odlaganje odpadkov. Če želite izdelek zavreči, prosimo, da to storite v skladu s predpisi, tako da ga odpeljete v bližnjo organizacijo, ki je
specializirana za odlaganje stare električne opreme.
Este símbolo indica que el producto así señalizado no debe desecharse como los residuos domésticos normales. Dado que es un producto de consumo profesional,
tampoco debe llevarse a centros de recogida selectiva municipales. Si desea desechar este producto, hágalo debidamente acudiendo a una organización de su zona que
esté especializada en el tratamiento de residuos de aparatos eléctricos usados.
Den här symbolen indikerar att produkten inte får blandas med normalt hushållsavfall då den är förbrukad. Eftersom produkten är en så kallad B2B-produkt är den inte
avsedd för privata konsumenter, den får således inte avfallshanteras på allmänna miljö- eller återvinningsstationer då den är förbrukad. Om ni vill avfallshantera den här
produkten på rätt sätt, ska ni lämna den till myndighet eller företag, specialiserad på avfallshantering av förbrukad elektrisk utrustning i ert närområde.

81



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 81
Language                        : de-DE
Tagged PDF                      : Yes
Title                           : Sebalog D3 Daten-Logger
Author                          : Doc-To-Help
Creator                         : Microsoft® Word 2010
Create Date                     : 2017:01:25 13:52:18+01:00
Modify Date                     : 2017:01:25 13:52:18+01:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools

Navigation menu