Somfy Glydea Installation & Programming Instructions 370S 3
User Manual: 370S-3
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
GLYDEA™ INSTALLATION AND PROGRAMMING INSTRUCTIONS Glydea™ Installation & Programming Instructions 1/2011 Glydea™ Installation Guide 1/4 MANDATORY SAFETY INSTRUCTIONS For Glydea™ actuators intended for fabric curtain tracks installed horizontally, and for indoor use only Any use outside the scope of application specified by SOMFY is non-compliant. SOMFY cannot be held liable for any such use or failure to observe these instructions, which will also result in warranty being voided. Should any doubt arise during installation of the motor or in order to obtain additional information, please visit the www.Somfy.com website or refer to your SOMFY contact (see branch details printed on this document). IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION WARNING: improper installation may result in serious injury. Follow the installation instructions in full, as well as those shown in the enclosed user leaflet. To be handed to the user. The motor must be installed by an installer who is qualified in motorized systems and domestic automation. The installer must inform the user of the need to arrange maintenance for the motorized unit and its associated accessories. He must specify items that require maintenance, replacement or checking. The torque, operating time and speed of the SOMFY actuator must be compatible with the specifications of the motorized unit: your SOMFY contact will provide a method of selecting motors for each application. -Use only accessories (Curtain track, brackets, etc.) listed by SOMFY to fit to a unit. Part numbers for accessories are available from your SOMFY contact. -Please refer to the SOMFY literature to ascertain the control points) compatible with the actuator selected. -In areas subject to frequent power cuts it will be necessary to install an emergency facility or backup power supply. -Fit control devices in visible positions. -A multi-pole switching device must be provided further up the power supply, i.e. a device which electrically isolates each active conductor simultaneously (minimum contact opening gap: 3.5 mm). -Protect cables routed through a wall with an insulated cable bushing. -If the cable or the power supply connector is damaged, return the actuator to the service department to avoid any risk. -Secure the cables to prevent any contact with moving parts. -Leave the power supply cable to the actuator accessible: it must be easily replaceable. -To reduce the risk of electric shock, this equipment must have a proper grounding. Some Motors versions are supplied with a grounding type plug, that has a third (grounding) pin. This plug will only fit into a grounding type outlet. If the plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. - A Motorized curtain track installation, equipped with two Glydea 60e motors, will be deemed safe if at least one of the following conditions is met (EN 13659 and EN 60 335-2-97) -The motorized curtain track is controlled by a control point without locking, installed within sight of the closing but away from moving parts and at a height of at least 1.50 m. -The crush zone is located at a height in excess of 2.50 m from the ground or any permanent access level. IMPORTANT SAFETY INSTRUCTIONS WARNING: it is important for everyone’s safety to follow these instructions in full. Keep these instructions for future reference. -Your installer should inform you of any maintenance required. -SOMFY recommends the presence of at least one control point close to the motorized unit or group of motorized units. -Do not allow children to play with fixed control devices. Keep remote controls out of the reach of children. -Do not use the emergency facility unless there is a mains power cut. -Keep a watch on the motorized unit while it is moving and ensure that people stay clear until the motorized unit is fully closed. -Disconnect the actuator from the power supply while maintenance work (e.g. window cleaning) is in progress in the vicinity. -Check the system frequently in order to detect any out-of-balance condition or signs of wear. Do not use the motorized unit if it needs repair or adjustment. -This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. -Children should be supervised to ensure that they do not play with the appliance. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ Installation Guide 2/4 A) Characteristics B) Measured 19.68” 1.37” .59” 4.33” 4.92” 19.68” 19.68” C) Installation of the rail [1] Mark the position of the bracket [2] Pierce the ceiling or the wall at the right places [3] Attach the brackets on it [4] Attach the rail on the bracket Glydea™ Installation & Programming Instructions 1/2011 [1] [1] [2] [2] [3] [3] [4] [4] Glydea™ Installation Guide 3/4 D) Power supply Cable output option: a) By the bottom of the motor through the notch of the wire cover b) By the top of the motor through the notch of the wire cover c) Through the pulley E) Installation of the motor [1] Unlock the motor [2] Insert the motor shaft in the drive pulley hole [3] Lock the motor Glydea™ Installation & Programming Instructions 1/2011 Glydea™ Installation Guide 4/4 F) Wiring of the motor [1] DCT & RTS motors [1] Power wiring 2 or 3 NO dry Contact & IR: 1: CCW (Open) NO Dry contact 2: IR OUT 3: Ground Common 4: +5V 5: Stop - NO Dry contact 6: CW (Close) NO Dry contact 7: Optional module socket [2] Motors equipped with a US power plug [2] Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 35 DCT Programming Instructions 1/2 A) Compatible controls And control wiring 1) DCT setting tool 2) Centralis IB 3) 2 NO (Normally Open) Dry contact switch 4) Somfy CS1 5) IR8 6) IR1 7) IR3 & RJ9/RJ12 adapter No parallel wiring of Glydea 35 DCT without DCT splitter B) Assign / Deleting a channel for IR8 transmitter Note: by factory default, the motor is paired to ALL channels on the transmitter. To designate one channel to a particular blind, the user must first delete unwanted channels. -To enter in programming mode: Press on the transmitter prog. Button until the curtain jogs. -To program one channel: Press on key 1 and next on the key of the channel to program ( 1 to 8 ) or channel group until the curtain jogs. -To exit programming mode: Press on the transmitter prog. Button until the curtain jogs. Program a channel Enter prog. mode Exit prog. mode Delete a channel Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 35 DCT Programming Instructions 2/2 C) Setting with 3 Normally open dry contact switches or IR control point Switch on the power supply. C C1 C1. Modifying the motor rotation direction Move the curtain away from the end limit. 1)Press the OPEN ( UP ), STOP and CLOSE ( DOWN ) buttons simultaneously until the curtain jogs. 2)Press the STOP button, until the curtain jogs to reverse the rotation direction. C2 C2. Dry contact ergonomics setting: Standard or 2 buttons sequencing 1) Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs to change the ergonomics. C3. Back release setting Move the curtain to the OPEN (UP) end limit 1)Press the STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs 2)Press and hold the CLOSE (DOWN) button to readjust the back release position 3)To confirm the new back release position, press and hold the STOP button until the curtain jogs For accuracy the positioning must be done in one movement. If the position is not satisfactory, go through the all procedure again To erase the back release position, set it on the hard stop limit C3 Note: Do set a back release position on thick curtain to warranty the drive shaft release to allow manual operation at open position. C4 C4. Erasing the memory of the motor. Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs 3 times. All the settings are erased. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 60e DCT Programming Instructions 1/5 A) Compatible controls And control wiring 1) DCT setting tool 2) Centralis IB 3) 2 NO (Normally Open) Dry contact switch 4) Somfy CS1 5) IR8 6) IR1 7) IR3 & RJ9/RJ12 adapter No parallel wiring of Glydea 35 DCT without DCT splitter B) Setting with 3 NO (Normally Open) dry contact switches or IR control point Switch on the power supply. After the first OPEN or CLOSE command, the curtain will run at reduced speed to one end, then the other to set the End Stops.. B1. Modifying the motor rotation direction Move the curtain away from the end limits. 1) Press the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the STOP button until the curtain jogs to reverse the rotation direction. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 60e DCT Programming Instructions 2/5 B2. End limit re-adjustment a) OPEN LIMIT 1) Press the OPEN (UP) button, to move the curtain to the open limit. 2) Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 3) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 4) To confirm the new limit press and hold the STOP button until the curtain jogs. b) CLOSE LIMIT 1) Press the CLOSE (DOWN) button to move the curtain to the close limit. 2) Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 3) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 4) To confirm the new limit press and hold the STOP button until the curtain jogs. Note: Do set an open limit position on thick curtain to warranty the drive shaft release to allow manual operation at open position. B3. Touch motion sensitivity 1) Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the OPEN (UP), and CLOSE (DOWN) buttons simultaneously to switch from no touch motion to low sensitivity to high sensitivity and back to no touch motion. 3) Press the STOP button until the curtain jogs to confirm the setting. B4. Dry contact ergonomics setting: Standard or 2 buttons sequencing 1) Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs to change the ergonomics. B2 a) B3 B4 Glydea™ Installation & Programming Instructions 1/2011 b) Glydea™ 60e DCT Programming Instructions 3/5 B5. Speed setting 1) Press and hold the OPEN (UP) and STOP buttons simultaneously until the curtain starts to open and close 2) Press OPEN (UP) to increase the speed, CLOSE (DOWN) to decrease the speed 3) Press the STOP button until the curtain jogs to confirm the setting. B6 B6. MY position 1) Recording MY position. To set the MY position, move the curtain to the desired position with the OPEN (UP) and CLOSE (DOWN) buttons then press the STOP button until the curtain jogs. 2) Delete the MY position To delete the MY position, move to this position and press the STOP button until the curtain jogs. B7 B7. Erasing the memory of the motor. Press and hold the OPEN (UP), STOP and CLOSE (DOWN) buttons simultaneously until the curtain jogs 3 times. All the settings are erased. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 60e DCT Programming Instructions 4/5 C) Setting using the Mode and Set motor buttons and a two button NO (Normally Open) dry contact switch. A Small paper clip is needed to press the Mode and Set buttons. After the first OPEN or CLOSE command, the curtain will run at reduced speed to one end, then the other to set the End Stops. C1. Press the M button until the green led switches on to enter in setting mode. You can exit from the setting mode at any time, by pressing the M button until the LED switches off. C2. Modifying the motor rotation direction 1) Press the S button to reverse the rotation direction. Green LED ON = Open/CCW, Green LED blinking = Open/CW 2) Press the M button to confirm the change and go to the next step. The red light is on. C3. Open End limit re-adjustment 1) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 2) Press the S button to memorize the open limit, the curtain moves to the close limit. It can be stopped by pressing the stop (MY) button. 3) Press the M button to confirm the change and go to the next step. The red light flashes. Note: Do set an open limit position on thick curtain to warranty the drive shaft release to allow manual operation at open position. C4. Close End limits re-adjustment 1) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 2) Press the S button to memorize the close limit, the curtain moves to the open limit. It can be stopped by pressing the stop (MY) button. 3) Press the M button to confirm the change and go to the next step. The Yellow LED is on or blinking. C5. Touch motion sensitivity 1) Press the S button to switch from no touch motion (yellow LED is on) to low sensitivity (Yellow LED blinks) to high sensitivity (Yellow LED blinks quicker). 2) Press the M button to confirm and go to the next step. The led flashes alternatively from green to red and the curtain starts to open and close. C6. Speed setting 1) Press the S button to switch the speed from 15 cm/s to 17.5 cm/s, to 20 cm/s, to 12.5 cm/s, and back to 15 cm/S 2) Press the M button to confirm and go back to direction setting. The green LED is on or blinking. C7. Erasing the memory of the motor Push the SET Button until the motor jogs 3 times and the Red LED turns on (12 seconds). It will light for 4 seconds, then the motor will reset. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ 60e DCT Programming Instructions 5/5 D Assign/Deleting a channel for IR 8 transmitter Note : to use a IR transmitter, you need to plug a IR sensor on the RJ 12 motor plug. D1 D1 Assign a channel Note : By factory default, the motor is paired to ALL channels on the transmitter. To designate one channel to a particular blind, the user must first delete unwanted channels (see step DELETE A CHANNEL). To enter in programming mode: Press on the transmitter prog button until the curtain jogs. To program one channel : press on key 1 and next on the key of the channel to program (1 to 8) or channel group until the curtain jogs. To exit programming mode: press on the transmitter prog button until the curtain jogs. D2 D2 Delete a channel To enter in programming mode: Press on the transmitter prog button until the curtain jogs. To erase one channel: press on key 8 and next on the key of the channel to remove (1 to 8) or channel group until the curtain jogs. To erase all channels: press on key 8 and next on key 1_8 until the motor curtain jogs. To exit programming mode : press on the transmitter prog button until the curtain jogs. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 1/6 Compatible controls OPTIONAL 1) Slide the RTS receiver into the notch (a) 2) Clip the RTS receiver into the plug (b) Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 2/6 Programming the RTS control point Switch on the power supply. Press the OPEN (UP) and CLOSE (DOWN) buttons simultaneously on the RTS control point: the curtain jogs. and the control point is preprogrammed in the motor. GLYDEA™ 60e RTS only The curtain makes a first run to record the hard stop positions at first command. Checking the direction of rotation 1) Press the RTS control point OPEN (UP) button: a) If the curtain opens, the direction of rotation is correct b) If the curtain closes, the direction of rotation is incorrect: move to the next step. 2) Press the RTS control point MY button until the curtain jogs: the direction of rotation has been modified. 3) Press the RTS control point OPEN (UP) button to check the direction of rotation. Recording the RTS control point Press the programming button on the back of the RTS control point until the motor jogs. The RTS control point address is permanently recorded. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 3/6 Back release setting GLYDEA™ 35 RTS only Move the curtain to the OPEN end limit. 1) Press the MY and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the CLOSE (DOWN) button to readjust the back release position. 3) To confirm the new back release position, press and hold the MY button until the curtain jogs. For accuracy the positioning must be done in one movement. If the position is not satisfactory, go through the all procedure again. 4)To erase the back release position, set it on the hard stop limit. Note: Do set a back release position on thick curtain to warranty the drive shaft release to allow manual operation at open position. MY position GLYDEA™ 60e RTS only 1) Recording MY position. To set the MY position, move the curtain to the desired position with the UP and DOWN buttons then press the MY button until the curtain jogs. 2) Delete the MY position To delete the MY position, move to this position and press the MY button until the curtain jogs. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 4/6 End limit re-adjustment GLYDEA™ 60e RTS only a) OPEN (UP) LIMIT 1) Press the OPEN (UP) button, to move the curtain to the limit to be readjusted. 2) Press and hold the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 3) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 4) To confirm the new limit press and hold the MY button until the curtain jogs. b) CLOSE LIMIT 1) Press the CLOSE (DOWN) button to move the curtain to the limit to be readjusted. 2) Press and hold the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 3) Press and hold the OPEN (UP) or CLOSE (DOWN) button to move the curtain to the new desired position. 4) To confirm the new limit press and hold the MY button until the curtain jogs. Note: Do set an open limit position on thick curtain to warranty the drive shaft release to allow manual operation at open position. Modifying the motor rotation direction Glydea™ 35 RTS and Glydea™ 60e RTS Move the curtain away from the end limits. 1) Press the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the MY button until the curtain jogs to reverse the rotation direction. Dry contact ergonomics setting Glydea™ 35 RTS and Glydea™ 60e RTS 1) Press the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtain jogs. 2) Press the MY and CLOSE (DOWN) buttons simultaneously until the curtain jogs to change the ergonomics. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 5/6 Touch motion sensitivity GLYDEA™ 60e RTS only 1) Press and hold the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtains jogs. 2) Press the OPEN (UP) and CLOSE (DOWN) buttons simultaneously until the curtain jogs to switch from no touch motion to low sensitivity; to high sensitivity and back to no touch motion. 3) Press the STOP button until the curtain jogs to confirm the setting. Speed setting GLYDEA™ 60e RTS ONLY 1) Press and hold the OPEN (UP) and STOP buttons simultaneously until the curtain starts to open and close 2) Press OPEN (UP) to increase the speed, CLOSE (DOWN) to decrease the speed 3) Press the STOP button until the curtain jogs to confirm the setting. Adding/Deleting RTS control points Glydea™ 35 RTS and Glydea™ 60e RTS Find an RTS control point programmed in the motor. Press and hold the RTS programmed control point (A) PROG button or the receiver PROG button until the curtain jogs: the motor is in programming mode. Quickly press the RTS control point (B) PROG button to add or delete: the curtain jogs and the RTS control point is programmed or deleted from the motor. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ RTS Receiver Programming Instructions 6/6 Adding/Deleting RTS sensors Find an RTS control point programmed in the motor. Press and hold the RTS programmed control point (A) PROG button or the receiver PROG button until the curtain jogs: the motor is in programming mode. Quickly press the RTS sensor (C) PROG button to add or delete: the curtain jogs and the RTS sensor is programmed or deleted from the motor. Erasing the transmitters of the motor To delete all the transmitters programmed, press and hold the receiver prog button until the curtain jogs twice. All the transmitters are deleted. Erasing the memory of the motor To reset the motor, press the receiver prog button until the curtain jogs 3 times. All the settings are erased. Glydea™ Installation & Programming Instructions 1/2011 Glydea™ Dry Contact & Glydea RTS Setting Sum Up Default Values Dry contacts setting Set Confirm and Exit Enter Enter In Temporary mode Direction change Open CCW Back release No Back release set Open Limit setting No end limits set Not at end limits Open+Stop+Close 4s Stop 2s to change & exit 1 jog 1 jog at open limit Stop+Close 4s 1 jog at open limits Open+Stop+Close 4s 1 jog Close limit setting No end limits set at close limits Open+Stop+Close 4s 1 jog Dry contact ergonomics Standard Speed setting 15 cm/s (fo a 6 m trach 35 KG) Open+stop 4s Touch Motion No touch Motion active Open+Stop+Close 4s Open or close to position curtain Stop 2s Open or close to position curtain Stop 2s Open or close to position curtain Stop 2s 1 jog 1 jog Stop+Close 2s to change and exit Open+Stop+Close 4s 1 jog Not at end limits Open+Close 4s Open to increase speed, Close to decrease speed Open+Close 2s to switch to different sensitivity (loop) Confirm and Exit Stop 2s to change direction 1 jog at open limit Stop+Close 4s at open limits Open+Close 4s 1 jog at close limits Open+Close 4s 1 jog Open or close to position curtain Stop 2s Open or close to position curtain Stop 2s Open or close to position curtain Stop 2s 1 jog 1 jog 1 jog 1 jog Limit management mode is erased if setting is done at hard Stop Limit mahagement mode is erased if setting is done at hard Stop 1 jog Stop 2s Open+stop 4s 1 jog 1 jog Stop 2s Open+Close 4s 1 jog 1 jog Open to increase speed, Close to decrease speed Open+Close 2s to switch to different sensitivity (loop) Open+Stop+Close less than 2s Open+Stop+Close less than 2s Open+Stop+Close 12s 3 jogs Receiver prog. buton 12s 3 jogs Glydea™ Installation & Programming Instructions 1/2011 Back release is erased if setting is done at hard Stop Stop+Close 2s to change and exit Open+Close 4s 1 jog Exit setting mode any time Fractory reset Comments Stop 2s to change Not at end limits for Glydea 60e & exit because conflict with Limit setting. 1 jog 1 jog 1 jog 1 jog 1 jog RTS setting Set 0pen and Close operationnal Stop 2s 1 jog Stop 2s 1 jog Touch motion function should be active in setting mode to test www.somfysystems.com Somfy Systems, Inc. North America Headquarters 121 Herrod Blvd. Dayton, NJ 08810 (P) 800 22 SOMFY (P) 609 395 1300 (F) 609 395 1776 Florida 6100 Broken Sound Pkwy Northwest Suite 14 Boca Raton, FL 33487 (P) 877 227 6639 (P) 561 995 8376 (F) 561 995 7502 California 15291 Barranca Pkwy Irvine, CA 92618 (P) 877 727 6639 (F) 949 727 3775 Somfy ULC Somfy Canada 6315 Shawson Drive Unit 1 Mississauga, Ontario L5T1J2 (P) 800 667 6639 (P) 905 564 6446 (F) 905 564 2679 Glydea™ Databook 1/2011 © Copyright Somfy Systems Inc. 2/2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2011:02:25 15:12:48Z Creator Tool : PrimoPDF http://www.primopdf.com/ Modify Date : 2011:03:13 10:16-04:00 Metadata Date : 2011:03:13 10:16-04:00 Format : application/pdf Creator : Automated Shade Store Title : Somfy Glydea Installation & Programming Instructions Description : Somfy Glydea Installation & Programming Instructions Subject : Somfy, Glydea, Installation, Programming, Instructions Producer : PrimoPDF Keywords : Somfy, Glydea, Installation, Programming, Instructions Document ID : uuid:408e3a85-0d94-429e-a9ad-980a36660611 Instance ID : uuid:3cb43570-70bf-4ad9-b856-9415ee280726 Page Count : 20 Author : Automated Shade Store Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools