Tube Axial Upblast Fans TAUD TAUDTAUB CA Catalog
User Manual: Tube Axial Upblast Fans TAUD
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
Tube Axial Roof Upblast Models TAUD & TAUB-CA with Cast Aluminum Propeller Direct & Belt Drive • Clean Air or Fume Exhaust • Spark Resistant Constructions September 2002 Features ® Tube Axial Roof Upblast Fans Greenheck’s tube axial upblast roof exhausters, both direct and belt drive, are designed to efficiently remove and disperse contaminated air. The upblast configuration is ideal for exhausting contaminants away from a building to prevent roof damage and re-entrainment of exhaust air. Greenheck’s versatile tube axial design can be used in most commercial and industrial applications. Typical applications include: • • • • General exhaust Industrial space ventilation Fume hood exhaust Paint booth exhaust TAUD Features: • Direct drive construction • Propeller diameters from 18 to 48 inch (457-1912 mm) • Volume Range: 2,800 to 46,000 cfm (4,760-78,100 m3/hr) • Static Pressure: Up to 1.0 inch wg (250 Pa) • Temperatures: Up to 110ºF (43ºC) TAUB-CA Features: • Spark resistant construction • Belt drive with motor and drives out of airstream • Propeller diameters from 18 to 60 inch (457-1524 mm) • Volume Range: 2,800 to 74,000 cfm (4,760-125,700 m3/hr) • Static Pressure: Up to 1.25 inches wg (310 Pa) • Temperatures: Up to 180ºF (82ºC) Cast Aluminum Propellers The TAUD and TAUB-CA use heavy-duty, cast aluminum airfoil propellers that are designed to meet a large range capacity and pressure requirements. All TAUD and TAUB-CA propellers are dynamically balanced to assure vibrationfree operation. All propellers are tightly secured to the fan or motor shaft with taper lock bushings. Enjoy Greenheck’s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. • Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15- or 25-day production cycles, depending upon their complexity. • Greenheck’s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. • Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. • Our 3D service allows you to download, at no charge, easy-to-use AutoDesk™ Revit™ 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com 2 Value Added Features ® AMCA Licensed Air Data and UL/cUL Listing All sizes and configurations of the TAUD and TAUB-CA have AMCA licensed air data. In addition, UL/cUL 705 Listing is available for both TAUD and TAUB-CA models. Motors may be either 50 or 60 Hz. TAUD and TAUB-CA are listed for Electrical UL/cUL 705 File no. 40001 Greenheck Fan Corporation certifies that the models TAUD and TAUB-CA tube axial fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Quality Design Construction includes heavy-gauge material used in the housing, windband, and curb cap. Rolled edges on the windband and damper blades are used for additional strength. Greenheck’s curb cap includes integral venturi and prepunched mounting holes. Electrostatic Powder Paint Powder coatings offer a uniform, durable, and high quality finish. Powder coating is a one-coat process applied over a phosphatized surface that generally meets or exceeds the corrosion resistance of a comparable wet paint. Greenheck offers a number of in-house coatings applied via electrostatic powder. The standard coating, Permatector™, is excellent for indoor or outdoor applications and is resistant to many common chemicals. For information on our complete offering of coatings, visit geenheck.com and navigate to Library/ Application Articles. Search for Performance Coatings for Ventilation Products for a comprehensive listing of coatings and a relative resistance chart. Maintenance / Serviceability The TAUB incorporates the following value added features that allow for quick and easy field service. • Bearing lubrication is performed through extended grease fittings located on the outside of the fan housing. • An adjustable motor base is provided for tightening the fan belts. • Propellers are easily removed with the use of taper lock bushings. Complete Assembly and Testing The TAUD and TAUB-CA are completely assembled and tested before shipment. Our inspectors check that the fan operates with minimal vibration and is electrically safe for field operation. Model Number Code TAUB – CA – 24 – 20 TAUD – 24 – 609 – A 20 Tube Axial Upblast D - Direct Drive Fan Size 18, 20, 24, 30, 36, 42, 48 Number of Blades 3, 4, 6 Blade Pitch Motor Horsepower 4 = 3 = 5 = 7 = 10 = 15 = 20 = 1/4 1/3 1/2 3/4 1 1½ 2 Fan RPM A = 1770 B = 1170 C = 870 F = 690 30 = 3 50 = 5 75 = 7½ 100 = 10 150 = 15 200 = 20 Tube Axial Upblast B - Belt Drive Cast Aluminum Prop Motor Horsepower 4 = 3 = 5 = 7 = 10 = 15 = 20 = 1/4 1/3 1/2 3/4 1 1½ 2 30 = 3 50 = 5 75 = 7½ 100 = 10 150 = 15 200 = 20 Fan Size J = 1425 K = 950 M = 3500 R = 2900 18, 20, 24, 30, 36, 42, 48, 54, 60 3 Standard Construction & Accessories ® Standard Construction Housing - Housings are continuously welded to prevent air leakage. The fan tube, curb cap, windband and motor cover are constructed of heavy-gauge steel with Permatector™ coating. Butterfly Dampers - Butterfly style dampers feature rolled edges for strength and weather protection. Damper stops maintain proper blade position when fan is operating. Gaskets line the edge of fan discharge for quiet damper closure. For sizes 18-30 aluminum material is standard and steel is standard for sizes 36-60. Aluminum blades optional on larger sizes. Bearings (Belt Drive) - Bearings are air handling quality, grease lubricated, pillow block type. Bearings are selected with a basic rating fatigue life L10 in excess of 40,000 hours (L50 at 200,000 hours) at each fan’s maximum operating speed. Extended Lube Lines (Belt Drive) - Extended lube lines with grease fittings allow bearing lubrication from the fan exterior. Belt and Bearing Tube (Belt Drive) - Belts, bearings, and drives are protected from the airstream by a heavy-gauge steel belt tube and bearing cover. Adjustable Motor Bases (Belt Drive) - Rigid structural steel motor bases are welded to the fan housing and include heavy-duty adjustment screws for belt tensioning. Drives (Belt Drive) - Greenheck offers either constant or adjustable speed drives for fan speed adjustments. Belts are static free and oil resistant. Motors - NEMA base-mounted motors are standard. Motors are available in open drip proof, totally enclosed, or explosion proof. Motor Cover (Belt Drive) - A weatherproof motor cover shields the motor and drive components from dust, dirt, and moisture. Motor cover meets OSHA standards. Accessories Outlet Screen - Outlet screens constructed of steel mesh shield dampers and fan discharge from debris. Fusible Link Damper Lifter - Automatically opens butterfly dampers when the air temperature below the damper blades exceeds 165ºF (74ºC). Damper blades held open to provide smoke and heat relief with no electric power required. Magnetic Latches - Magnetic damper latches minimize damper flutter (due to pressure changes within the building) when the fan is not in operation. Inspection Door - A bolted or hinged inspection door provides access through the fan tube for cleaning or inspection of the propeller, bearings, and drives. Inlet Guard - Inlet guards provide protection for personnel and equipment in ducted or non-ducted installations. Inlet guards meet OSHA standards. Extended Wiring (Direct Drive) - Motor wiring is extended to the exterior of the fan casing for easy installation of the unit in the field. Tie Down Points - A set of 4 tie down points are used to secure the fan to the roof deck when wind loading is a concern. Shaft Seal - Shaft seals with aluminum rub rings are available to prohibit leakage of air into the bearing compartment of the fan. Roof Curbs - A complete line of prefabricated roof curbs are available for mounting Model TAUD and TAUB fans. See the Greenheck Roof Curbs, Extensions & Equipment Supports catalog. 4 Special Coatings - Special coatings are available for protective purposes. Coatings are applied before assembly so each manufactured component is coated inside and out. Painting the exterior a specified color for appearance is also an option. For information on our complete offering of coatings, visit geenheck.com and navigate to Library/Application Articles. Search for Performance Coatings for Ventilation Products for a comprehensive listing of coatings and a relative resistance chart. Disconnect Switches - Toggle and heavy-duty disconnect switches are available for positive electrical shut-off and safety in servicing fans. The following switches are available to meet individual electrical requirements and can be factory-mounted or shipped loose for field mounting. • NEMA-3R — Rainproof (outdoor) • NEMA-4 — Watertight (outdoor) • NEMA-7 & 9 — Class 1 and 2 hazardous locations. Greenheck will not factory-mount NEMA-7 & 9 disconnect switches. Motor Starters - The fundamental function of a motor starter is to protect the motor from damage that can occur from overheating. With a Greenheck motor starter you will be provided with the best motor protection available. Specific model components may include SmartStart™ technology, physical interface, overload protection, disconnect, magnetic contactor, NEMA-1 or NEMA-3R steel enclosures and pre-engineered easy system integration. For complete information on specific Greenheck Motor Starter models, visit our motor starter web page on geenheck.com. Accessories ® Outlet Screen Aluminum Damper Blades Fusible Link Damper Lifter Inspection Door Tie Down Points Inlet Guard 5 TAUD-18 Direct Drive ® Specifications 25.00 (635) Max frpm = 1725 Outlet Velocity (fpm) = cfm / 3.41 ft2 Tip Speed = frpm x 4.71 44.00 (1118) 21.25 (540) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 2752 Steel Dampers: 3526 Max Motor Frame Size = 145T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 145 lbs. (66 kg.) Recommended Roof Opening = 201/2 x 201/2 in. (521 x 521 mm) Dimensions are shown in inches (millimeters). 26.00 (660) 2.50 (64) TAUD Performance Data Model Number Motor HP CFM / Static Pressure in Inches WG Fan RPM Max BHP 0.000 0.050 0.100 0.125 0.250 0.375 0.500 CFM CFM CFM CFM CFM CFM CFM 1978 18-438 1/4 1140 0.28 2854 2688 2491 2402 18-631 1/4 1140 0.27 2914 2780 1631 2556 18-638 1/3 1140 0.36 3121 2975 2823 2739 18-413 1/4 1725 0.27 2795 2712 2625 2574 18-316 1/4 1725 0.28 2913 2812 2708 2652 2343 18-615 1/3 1725 0.36 2953 2891 2830 2799 2605 18-418 1/3 1725 0.38 3201 3118 3035 2991 2731 18-324 1/2 1725 0.43 3428 3303 3180 3119 2818 2457 18-423 1/2 1725 0.54 3590 3498 3406 3357 3090 2785 18-330 1/2 1725 0.59 3741 3632 3502 3433 3097 2734 3052 2369 18-622 3/4 1725 0.61 3661 3591 3521 3486 3283 18-338 3/4 1725 0.78 3971 3834 3708 3650 3337 2763 18-435 3/4 1725 0.89 4207 4103 3998 3945 3646 3340 18-628 1 1725 0.81 4163 4081 3999 3958 3725 3480 3196 18-634 1 1725 1.08 4584 4490 4395 4348 4108 3842 3536 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 6 TAUD-20 Direct Drive ® Specifications 27.25 (692) Max frpm = 1725 Outlet Velocity (fpm) = cfm / 4.05 ft2 Tip Speed = frpm x 5.23 46.13 (1172) 22.38 (568) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 3169 Steel Dampers: 4087 Max Motor Frame Size = 145T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 160 lbs. (73 kg.) Recommended Roof Opening = 201/2 x 201/2 in. (521 x 521 mm) Dimensions are shown in inches (millimeters). 30.00 (762) 2.50 (64) TAUD Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.050 0.100 0.125 0.250 0.375 0.500 CFM CFM CFM CFM CFM CFM CFM 2992 20-331 1/4 1140 0.28 3513 3270 3042 2921 20-621 1/4 1140 0.28 3423 3283 3140 3067 20-428 1/4 1140 0.30 3626 3436 3237 3126 20-433 1/3 1140 0.37 3837 3627 3428 3319 20-626 1/3 1140 0.38 3870 3686 3511 3426 20-637 1/2 1140 0.59 4448 4273 4087 3989 20-311 1/4 1725 0.26 3318 3183 3053 2990 2961 20-410 1/3 1725 0.30 3375 3268 3162 3110 20-314 1/3 1725 0.37 3775 3653 3533 3473 3105 20-613 1/2 1725 0.58 3928 3857 3788 3754 3526 3292 20-417 1/2 1725 0.59 4353 4242 4131 4076 3781 3453 3070 20-321 3/4 1725 0.62 4573 4450 4321 4248 3874 3474 3033 20-619 1 1725 0.89 4864 4779 4693 4650 4419 4168 3860 20-329 1 1725 0.89 5197 5039 4882 4804 4410 4000 3552 3798 20-424 3/4 1725 1.86 5102 4992 4883 4828 4482 4164 20-335 1 1725 1.11 5475 5337 5196 5107 4660 4215 20-623 1 1725 1.12 5438 5339 5240 5191 4926 4656 4376 20-430 1 1725 1.13 5568 5447 4327 5267 4926 4573 4187 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 7 TAUDTAUD-24 Direct Drive Direct Drive ® Specifications 31.13 (791) Max frpm = 1725 Outlet Velocity (fpm) = cfm / 5.28 ft2 Tip Speed = frpm x 6.28 48.50 (1232) 22.13 (562) 34.00 (864) 2.50 (64) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 3947 Steel Dampers: 5220 Max Motor Frame Size = 184T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 225 lbs. (102 kg.) Recommended Roof Opening = 261/2 x 261/2 in. (673 x 673 mm) Dimensions are shown in inches (millimeters). TAUD Performance Data Model Number Motor HP Fan RPM CFM / Static Pressure in Inches WG Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 24-431 1/4 860 0.29 4793 3756 24-624 1/4 860 0.29 4762 3995 24-438 1/3 860 0.37 5090 4038 24-414 1/4 1140 0.25 4491 3883 3123 24-318 1/4 1140 0.27 4738 4005 3075 24-613 1/3 1140 0.35 4639 4179 3659 24-323 1/3 1140 0.36 5255 4461 3528 24-419 1/3 1140 0.36 5247 4562 3843 24-621 1/2 1140 0.57 5907 5352 4760 24-427 1/2 1140 0.56 6038 5345 4540 4114 24-335 3/4 1140 0.60 6020 5151 24-438 3/4 1140 0.87 6747 5977 5029 24-630 3/4 1140 0.87 6886 6269 5625 4920 24-635 1 1140 1.14 7383 6740 6072 5300 24-409 1/2 1725 0.58 5565 5177 4767 4339 3832 24-311 1/2 1725 0.58 5741 5320 4823 4257 3565 24-605 1/2 175 0.57 4602 4313 4031 3703 24-610 3/4 1725 0.90 5935 5673 5379 5065 4725 4347 3919 24-414 1 1725 0.90 6795 6422 5996 5580 5087 4501 3803 24-318 1 1725 0.95 7170 6750 6510 5653 5030 4380 24-613 1-1/2 1725 1.23 7020 6723 6415 6100 5760 5357 4950 24-419 1-1/2 1725 1.26 7940 7508 7039 6583 6103 5580 5013 24-323 1-1/2 1725 1.25 7952 7484 6917 6340 5707 5076 24-618 1-1/2 1725 1.70 8328 7968 7617 7272 6914 6516 6099 5750 24-424 1-1/2 1725 1.68 8757 8293 7853 7376 6862 6319 24-330 1-1/2 1725 1.76 8739 8179 7586 6999 6401 5724 8022 7620 24-624 3 1725 2.35 9552 9206 8835 8426 24-338 2 1725 2.31 9277 8702 8106 7508 7183 24-432 2 1725 2.33 9614 9121 8648 8108 7546 6989 6404 24-632 3 1725 3.33 10695 10288 9901 9527 9073 8594 8095 5657 6740 7603 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 8 TAUDTAUD-30 Direct Drive Direct Drive ® Specifications 37.38 (949) Max frpm = 1725 Outlet Velocity (fpm) = cfm / 7.62 ft2 Tip Speed = frpm x 7.85 53.75 (1365) 24.50 (622) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 6043 Steel Dampers: 7129 Max Motor Frame Size = 184T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 280 lbs. (280 kg.) Recommended Roof Opening = 321/2 x 321/2 in. (826 x 826 mm) Dimensions are shown in inches (millimeters). 40.00 (1016) 2.50 (64) TAUD Performance Data Model Number CFM / Static Pressure in Inches WG Motor HP Fan RPM Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 30-414 1/4 860 0.29 6820 5519 30-613 1/3 860 0.39 7328 6271 4979 30-420 1/3 860 0.40 7779 6426 4523 30-426 1/2 860 0.58 8775 7272 5464 6313 30-619 1/2 860 0.59 8742 7626 30-335 3/4 860 0.61 8677 6995 30-627 3/4 860 0.88 10082 8907 7486 30-634 1 860 1.15 10898 9636 8215 30-411 1/2 1140 0.52 8291 7382 6288 30-608 1/2 1140 0.57 7662 6945 6159 4823 5194 30-317 3/4 1140 0.61 9037 7818 6554 4588 30-322 3/4 1140 0.83 9935 8750 7376 5731 30-613 1 1140 0.93 9714 8944 8109 7212 5962 30-616 1 1140 1.11 10461 9676 8878 7962 6740 30-423 1 1140 1.15 11033 10010 8876 7438 30-431 1-1/2 1140 1.67 12386 11119 9997 8663 30-624 2 1140 1.78 12699 11834 11022 10031 8782 30-630 2 1140 2.27 13691 12762 11812 10837 9695 30-309 1 1725 1.10 10633 9892 9084 8311 7275 6144 30-406 1 1725 1.13 9765 9240 8559 7832 7119 6200 5208 30-603 1-1/2 1725 1.20 8202 7776 7257 6699 6171 5619 30-606 1-1/2 1725 1.66 10515 10085 9620 9094 8543 7989 7376 5795 30-608 2 1725 1.99 11593 11160 10667 10155 9636 9088 8436 7055 30-411 2 1725 1.85 12545 11936 11342 10628 9916 1942 8211 30-317 2 1725 2.12 13675 12850 12053 11306 10485 9487 8294 30-414 2 1725 2.33 13679 13075 12437 11770 11086 10319 9476 7129 30-613 3 1725 3.20 14698 14202 13693 13143 12591 12038 11446 10026 30-420 3 1725 3.26 15604 15050 14433 13700 12908 12167 11333 9147 30-327 5 1725 5.34 17835 16866 16063 15136 14101 12726 30-622 5 1725 5.44 18249 17750 17231 16674 16115 15555 14890 13585 30-429 5 1725 5.37 18144 17485 16789 16045 15137 14287 13450 11405 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 9 TAUD-36 Direct Drive ® Specifications 43.50 (1105) Max frpm = 1725 Outlet Velocity (fpm) = cfm / 10.32 ft2 Tip Speed = frpm x 9.42 56.38 (1432) 24.63 (626) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 7618 Steel Dampers: 10981 Max Motor Frame Size = 215T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 410 lbs. (186 kg.) Recommended Roof Opening = 381/2 x 381/2 in. (978 x 978 mm) Dimensions are shown in inches (millimeters). 46.00 (1168) 2.50 (64) TAUD Performance Data CFM / Static Pressure in Inches WG Model Number Motor HP Fan RPM Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 7034 8971 7352 11387 9766 13855 12293 36-412 1/2 860 0.55 10477 8942 36-608 1/2 860 0.59 9546 8527 7194 36-612 3/4 860 0.83 11480 10382 9016 36-322 3/4 860 0.83 12665 10690 8268 7342 36-329 1 860 1.13 13918 11826 9379 36-617 1 860 1.13 13310 12109 10709 36-432 1-1/2 860 1.71 15642 13908 11893 36-625 1-1/2 860 1.76 15837 14544 13004 11218 12363 36-631 2 860 2.34 17286 15871 14201 36-640 3 860 3.29 19008 17401 15604 9005 36-305 1/2 1140 0.56 10247 8853 7224 36-403 3/4 1140 0.61 9055 7828 6485 36-407 3/4 1140 0.86 11543 10434 9142 7706 36-604 1 1140 0.94 9714 8809 7868 6873 5960 36-410 1 1140 1.09 13019 11955 10724 9296 7531 36-610 1-1/2 1140 1.63 14096 13235 12375 11391 10292 36-320 1-1/2 1140 1.63 15975 14533 13015 11221 8897 36-615 2 1140 2.30 16408 15638 14714 13738 12637 36-325 2 1140 2.31 17779 16284 14703 12863 10835 15203 36-612 3 1140 3.26 19184 18359 17402 16358 36-440 5 1140 5.39 22090 20654 18751 16760 36-631 5 1140 5.44 22914 21960 20736 19492 18177 16785 14977 36-305 2 1725 1.96 15506 14562 13668 12686 11608 10396 9099 36-403 2 1725 2.13 13702 12906 12084 11182 10301 9409 8433 36-407 3 1725 2.97 17466 166988 15992 15208 14349 13458 12558 36-604 3 1725 3.27 14699 14096 13499 12912 12279 11633 10985 10444 9507 36-610 5 1725 5.66 21330 20758 20187 19635 19083 18456 17816 16461 36-302 5 1725 5.64 24172 23316 22331 21181 20264 19228 18105 15416 36-615 7-1/2 1725 7.90 24828 24319 23811 23254 22628 22001 21353 20011 36-325 7-1/2 1725 8.10 26903 25900 24919 23955 22879 21735 20502 18116 36-612 10 1725 11.31 29028 28483 27938 27376 26715 26054 25376 23939 36-427 10 1725 11.16 29680 28872 28042 27119 26197 25195 24193 22056 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 10 TAUD-42 Direct Drive ® Specifications 49.88 (1267) Max frpm = 1140 Outlet Velocity (fpm) = cfm / 13.57 ft2 Tip Speed = frpm x 10.99 66.88 (1699) 30.25 (768) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 11045 Steel Dampers: 13551 Max Motor Frame Size = 256T Fan Tube Gauge = 10 ga. Windband Gauge = 20 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 620 lbs. (281 kg.) Recommended Roof Opening = 441/2 x 441/2 in. (1130 x 1130 mm) Dimensions are shown in inches (millimeters). 52.00 (1321) 2.50 (64) TAUD Performance Data Model Number Motor HP Fan RPM 42-322 3/4 42-418 3/4 42-617 CFM / Static Pressure in Inches WG Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 680 0.83 15944 12042 680 0.84 16104 13125 1 680 1.09 16983 14705 42-423 1 680 1.15 17791 14433 11747 42-623 1-1/2 680 1.73 20045 17454 42-632 2 680 2.33 21959 19186 14434 15981 42-607 1 860 1.16 16247 14586 12640 10369 42-412 1 860 1.14 17521 15124 12711 8912 14164 11012 15407 12217 42-614 2 860 1.82 20023 18144 16358 42-322 1-1/2 860 1.68 20165 17207 13881 42-418 1-1/2 860 1.73 20367 18071 15341 42-617 2 860 2.23 21479 19746 17790 42-329 2 860 2.28 21728 18967 15056 42-423 2 860 2.33 22500 19844 17114 42-432 3 860 3.36 24735 22160 19148 13568 42-623 3 860 3.26 25086 23084 20771 42-403 1-1/2 1140 1.22 15798 14104 12253 10216 42-305 1 1140 1.10 16620 14498 12345 19661 18306 14921 42-603 2 1140 1.83 17255 15865 14508 13034 11528 42-309 1-1/2 1140 1.62 19647 17566 15433 12758 9315 42-606 2 1140 2.29 19883 18576 17201 15602 14185 12307 42-408 1-1/2 1140 1.74 20501 18861 17113 15068 12948 10037 11917 42-411 3 1140 2.41 22278 20646 18858 16985 14843 42-314 2 1140 2.28 22553 20365 17888 15585 12418 9830 42-610 3 1140 3.29 23607 22368 21017 19645 18022 16409 42-414 3 1140 3.09 24559 22920 21014 18944 16776 13969 42-318 3 1140 3.12 24639 22727 20307 17555 14635 10192 42-617 5 1140 5.17 28472 27178 25852 24362 22857 21004 42-329 5 1140 5.31 28803 26775 24566 21752 10430 14474 18936 42-423 5 1140 5.43 29826 27993 25834 23791 21574 18851 42-623 7-1/2 1140 8.14 33605 32342 30599 28963 27341 25606 23319 42-632 10 1140 10.98 36814 35197 33468 31879 30373 28412 25503 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 11 TAUD-48 Direct Drive ® Specifications 56.00 (1422) Max frpm = 1140 Outlet Velocity (fpm) = cfm / 17.10 ft2 Tip Speed = frpm x 12.56 69.13 (1756) 32.50 (826) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 12817 Steel Dampers: 16421 Max Motor Frame Size = 256T Fan Tube Gauge = 10 ga. Windband Gauge = 20 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 800 lbs. (363 kg.) Recommended Roof Opening = 501/2 x 501/2 in. (1283 x 1283 mm) Dimensions are shown in inches (millimeters). 58.00 (1473) 2.50 (64) TAUD Performance Data Model Number Motor HP Fan RPM CFM / Static Pressure in Inches WG Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 48-606 3/4 680 0.80 17281 14480 48-411 3/4 680 0.84 19416 15634 48-610 1 680 1.13 20608 17538 48-415 1 680 1.11 21591 17609 14279 48-421 1-1/2 680 1.65 24856 20085 14657 48-616 1-1/2 680 1.73 24960 21814 18362 12957 48-428 2 680 2.32 27137 22361 48-620 2 680 2.26 27710 24264 20373 14484 48-627 3 680 3.37 30936 27426 23440 48-406 1 860 1.13 20865 17861 14501 48-309 1 860 1.17 22190 18909 14710 10000 48-603 1-1/2 860 1.23 18685 16305 13892 11219 48-606 1-1/2 860 1.63 21855 19759 17272 14596 11310 48-315 2 860 1.78 25688 22087 17714 48-610 2 860 2.30 26063 23652 21248 18687 15353 48-415 2 860 2.22 27306 24307 20872 16462 48-320 3 860 2.38 28319 24040 19643 12735 48-615 3 860 3.32 30561 28356 25795 22913 48-421 3 860 3.33 31435 27781 23768 19430 19656 14452 48-432 5 860 5.38 34762 30921 26916 18798 48-622 5 860 5.33 36360 33983 31147 27936 24197 48-404 2 1140 2.16 24531 22523 20517 17712 14906 11689 48-306 2 1140 1.98 25047 22972 20115 16703 48-604 3 1140 3.15 25989 24488 22745 21044 19159 16975 48-407 3 1140 3.03 29135 26745 24444 22036 19168 15790 48-610 5 1140 5.36 34549 32774 30884 29069 27269 25372 23036 48-415 5 1140 5.22 36197 33860 31629 29022 26322 22965 18261 14628 17275 48-320 5 1140 5.53 37539 34093 31180 27899 24175 18793 48-421 7-1/2 1140 7.77 41670 39064 36104 33094 29956 26675 22607 48-616 7-1/2 1140 8.25 41845 39800 38022 36171 34129 32211 29822 23459 48-428 10 1140 10.95 45494 42436 39795 36965 33917 48-620 10 1140 10.58 46455 44268 42243 40371 38672 36005 32978 26099 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. 12 TAUB-CA-18 Belt Drive ® Specifications 25.00 (635) Max frpm = 2235 Outlet Velocity (fpm) = cfm / 3.41 ft2 Tip Speed = frpm x 4.71 Max Motor Frame Size = 145T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 180 lbs. (82 kg.) Recommended Roof Opening = 201/2 x 201/2 in. (521 x 521 mm) 48.25 (1226) 25.50 (648) 21.75 (552) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 2752 Steel Dampers: 3526 2.50 (64) Dimensions are shown in inches (millimeters). 26.00 (660) TAUB-CA Performance Data Max BHP CFM / Static Pressure in Inches WG Model Number Motor HP Fan RPM 18-5 1/2 1400 0.40 2980 2745 18-5 1/2 1435 0.44 3055 2826 18-5 1/2 1470 0.47 3129 2907 18-5 1/2 1505 0.50 3204 2987 2737 18-5 1/2 1545 0.54 3289 3079 2837 18-7 3/4 1575 0.58 3353 3148 2911 2658 18-7 3/4 1615 0.62 3438 3239 3010 2764 18-7 3/4 1655 0.67 3523 3330 3108 2870 18-7 3/4 1695 0.72 3608 3421 3206 2975 2723 18-7 3/4 1735 0.77 3693 3510 3303 3079 2840 18-7 3/4 1775 0.83 3778 3600 3399 3180 2951 2687 18-10 1 1815 0.88 3864 3689 3495 3281 3059 2808 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 18-10 1 1850 0.93 3938 3766 3578 3369 3152 2912 18-10 1 1885 0.99 4013 3844 3660 3457 3245 3015 2739 18-10 1 1920 1.05 4087 3922 3742 3543 3337 3118 2870 18-10 1 1955 1.10 4162 3999 3824 3630 3429 3219 2976 18-15 1-1/2 2010 1.19 4279 4121 3951 3765 3572 3368 3140 18-15 1-1/2 2055 1.28 4374 4220 4055 3875 3686 3489 3274 2678 18-15 1-1/2 2100 1.37 4470 4319 4159 3984 3800 3608 3406 2860 18-15 1-1/2 2145 1.46 4566 4418 4263 4093 3912 3727 3536 3039 18-15 1-1/2 2190 1.55 4662 4517 4366 4202 4025 3845 3658 3215 18-15 1-1/2 2235 1.65 4758 4616 4469 4310 4136 3962 3779 3368 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 13 TAUB-CA-20 Belt Drive ® Specifications 27.25 (692) Max frpm = 2190 Outlet Velocity (fpm) = cfm / 4.05 ft2 Tip Speed = frpm x 5.23 Max Motor Frame Size = 182T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 205 lbs. (93 kg.) Recommended Roof Opening = 221/2 x 221/2 in. (572 x 572 mm) 51.50 (1308) 27.75 (705) 23.25 (591) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 3169 Steel Dampers: 4087 Dimensions are shown in inches (millimeters). 2.50 (64) 30.00 (762) TAUB-CA Performance Data Model Number Motor HP Fan RPM 20-5 1/2 20-5 1/2 CFM / Static Pressure in Inches WG Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 1265 0.4 3679 3358 2980 2333 1310 0.45 3810 3502 3143 2630 20-5 1/2 1355 0.49 3941 3645 3305 2858 20-5 1/2 1400 0.55 4072 3788 3464 3069 20-7 3/4 1445 0.6 4203 3930 3617 3264 2591 20-7 3/4 1500 0.67 4363 4102 3802 3468 2954 20-7 3/4 1550 0.74 4508 4259 3969 3652 3231 20-7 3/4 1600 0.82 4653 4414 4134 3834 3466 20-10 1 1635 0.87 4755 4523 4250 3960 3629 2798 3024 20-10 1 1680 0.95 4886 4662 4396 4121 3811 3322 20-10 1 1725 1.02 5017 4801 4542 4277 3979 3574 20-10 1 1770 1.11 5148 4940 4687 4430 4145 3787 3174 20-15 1-1/2 1800 1.16 5235 5031 4784 4531 4254 3927 3373 20-15 1-1/2 1845 1.25 5366 5167 4928 4683 4418 4136 3670 20-15 1-1/2 1890 1.35 5497 5303 5072 4833 4580 4305 3917 20-15 1-1/2 1935 1.44 5628 5438 5215 4982 4741 4472 4130 20-15 1-1/2 1980 1.55 5759 5573 5357 5131 4899 4638 4340 20-15 1-1/2 2025 1.65 5890 5708 5499 5278 5052 4802 4546 20-20 2 2055 1.73 5977 5798 5594 5376 5153 4911 4658 3546 3737 20-20 2 2100 1.85 6108 5933 5735 5522 5305 5073 4826 4038 20-20 2 2145 1.96 6239 6068 5876 5667 5456 5235 4992 4333 20-20 2 2190 2.09 6369 6202 6016 5812 5606 5395 5158 4559 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 14 TAUB-CA-24 Belt Drive ® Specifications 31.13 (791) Max frpm = 1975 Outlet Velocity (fpm) = cfm / 5.28 ft2 Tip Speed = frpm x 6.28 Max Motor Frame Size = 184T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 280 lbs. (127 kg.) Recommended Roof Opening = 261/2 x 261/2 in. (673 x 673 mm) 52.75 (1340) 26.38 (670) 26.00 (660) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 3947 Steel Dampers: 5220 2.50 (64) Dimensions are shown in inches (millimeters). 34.00 (864) TAUB-CA Performance Data Model Number Motor HP CFM / Static Pressure in Inches WG Fan RPM Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 24-5 1/2 1015 0.43 5242 4696 4059 24-5 1/2 1060 0.48 5474 4956 4360 3598 24-5 1/2 1105 0.55 5706 5213 4648 3964 24-7 3/4 1160 0.64 5990 5526 4994 4399 3532 24-7 3/4 1215 0.73 6274 5836 5336 4780 4076 24-7 3/4 1270 0.83 6558 6144 5669 5153 4529 24-10 1 1295 0.88 6687 6284 5818 5320 4730 24-10 1 1345 0.99 6946 6561 6113 5640 5118 24-10 1 1395 1.1 7204 6838 6406 5956 5465 3991 24-15 1-1/2 1440 1.21 7436 7086 6667 6237 5772 4519 24-15 1-1/2 1480 1.32 7643 7306 6898 6485 6041 4914 24-15 1-1/2 1520 1.42 7849 7525 7128 6731 6301 5260 24-15 1-1/2 1560 1.53 8056 7744 7357 6971 6556 5584 24-20 2 1600 1.66 8262 7962 7585 7208 6809 5904 24-20 2 1645 1.81 8495 8207 7840 7474 7091 6253 5040 24-20 2 1685 1.95 8701 8424 8066 7708 7340 6531 5438 24-20 2 1725 2.09 8908 8641 8291 7942 7587 6806 5827 24-30 3 1775 2.27 9166 8911 8571 8232 7892 7146 6235 24-30 3 1825 2.47 9424 9181 8851 8520 8190 7482 6638 5492 24-30 3 1875 2.68 9683 9450 9129 8807 8486 7803 7034 5992 24-30 3 1925 2.91 9941 9715 9406 9093 8780 8121 7398 6483 24-30 3 1975 3.13 10199 9979 9683 9377 9072 8437 7743 6894 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 15 TAUB-CA-30 Belt Drive ® 37.38 (949) Specifications Max frpm = 1810 Outlet Velocity (fpm) = cfm / 7.62 ft2 Tip Speed = frpm x 7.85 Max Motor Frame Size = 213T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 370 lbs. (168 kg.) Recommended Roof Opening = 321/2 x 321/2 in. (826 x 826 mm) 56.75 (1441) 27.50 (699) 31.25 (794) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 6043 Steel Dampers: 7129 Dimensions are shown in inches (millimeters). 2.50 (64) 40.00 (1016) TAUB-CA Performance Data Model Number Motor HP 30-5 1/2 30-5 1/2 30-7 3/4 30-7 3/4 30-10 30-10 30-10 Fan RPM CFM / Static Pressure in Inches WG Max BHP 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 820 0.49 7864 6807 5588 860 0.56 8247 7242 6112 900 0.64 8631 7673 6626 940 0.73 9015 8100 7130 5854 1 980 0.83 9398 8523 7600 6480 1 1015 0.92 9734 8892 8003 6985 1 1045 1.01 10022 9205 8346 7379 6041 30-10 1 1075 1.09 10309 9518 8686 7767 6595 30-15 1-1/2 1125 1.25 10789 10033 9246 8403 7380 30-15 1-1/2 1180 1.44 11316 10597 9849 9072 8171 30-15 1-1/2 1235 1.66 11844 11158 10445 9709 8887 6396 30-20 2 1265 1.78 12131 11462 10768 10053 9272 7069 30-20 2 1300 1.94 12467 11817 11142 10450 9715 7811 30-20 2 1335 2.06 12803 12170 11515 10845 10153 8368 30-30 3 1400 2.41 13426 12824 12202 11568 10911 9380 30-30 3 1465 2.77 14049 13475 12884 12278 11657 10267 8259 30-30 3 1530 3.16 14673 14124 13561 12980 12393 11108 9481 30-50 5 1575 3.44 15104 14572 14025 13463 12898 11682 10188 7815 30-50 5 1635 3.85 15680 15168 14641 14103 13559 12434 11109 9169 30-50 5 1695 4.29 16255 15763 15254 14738 14213 13135 11899 10352 30-50 5 1755 4.76 16830 16357 15865 15369 14863 13828 12677 11299 30-50 5 1810 5.23 17358 16899 16423 15944 15453 14456 13379 12150 6790 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 16 TAUB-CA-36 Belt Drive ® 43.50 (1105) Specifications Max frpm = 1700 Outlet Velocity (fpm) = cfm / 10.32 ft2 Tip Speed = frpm x 9.42 Max Motor Frame Size = 215T Fan Tube Gauge = 12 ga. Windband Gauge = 20 ga. Curb Cap = 12 ga. Approx. Weight (LM) = 500 lbs. (227 kg.) Recommended Roof Opening = 381/2 x 381/2 in. (978 x 978 mm) 64.38 (1635) 32.63 (829) 33.75 (857) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 7618 Steel Dampers: 10981 2.50 (64) Dimensions are shown in inches (millimeters). 46.00 (1168) TAUB-CA Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 36-7 3/4 745 0.65 11255 9741 7659 36-7 3/4 800 0.82 12086 10685 8925 36-10 1 820 0.88 12388 11024 9359 6752 36-10 1 850 0.98 12841 11531 9966 7671 36-10 1 880 1.09 13294 12033 10564 8537 36-15 1-1/2 930 1.28 14050 12862 11533 9824 7220 36-15 1-1/2 970 1.45 14654 13519 12274 10716 8521 36-15 1-1/2 1010 1.65 15258 14172 13006 11579 9683 36-20 2 1040 1.8 15712 14659 13541 12185 10482 36-20 2 1065 1.93 16089 15064 13973 12685 11122 36-20 2 1095 2.09 16542 15548 14489 13278 11817 36-30 3 1145 2.4 17298 16352 15342 14237 12921 9048 36-30 3 1200 2.76 18129 17231 16272 15253 14052 10788 36-30 3 1255 3.15 18960 18106 17193 16255 15147 12352 36-50 5 1305 3.54 19715 18894 18021 17125 16120 13638 9857 36-50 5 1365 4.05 20621 19836 19007 18155 17233 15004 11850 36-50 5 1425 4.63 21528 20776 19987 19175 18332 16307 13597 36-50 5 1485 5.23 22434 21713 20962 20186 19396 17518 15189 11915 36-75 7-1/2 1535 5.77 23190 22492 21770 21023 20258 18511 16409 13511 36-75 7-1/2 1590 6.41 24021 23347 22655 21934 21200 19588 17631 15110 36-75 7-1/2 1645 7.12 24851 24200 23537 22840 22134 20612 18821 16589 36-75 7-1/2 1700 7.85 25682 25052 24415 23741 23061 21625 19932 17982 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 17 TAUB-CA-42 Belt Drive ® 49.88 (1267) Specifications Max frpm = 1580 Outlet Velocity (fpm) = CFM / 13.57 ft2 Tip Speed = frpm x 10.99 Max Motor Frame Size = 215T Fan Tube Gauge = 10 ga. Windband Gauge = 20 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 670 lbs. (304 kg.) Recommended Roof Opening = 441/2 x 441/2 in. (1130 x 1130 mm) 71.00 (1803) 34.25 (870) 37.25 (946) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 11045 Steel Dampers: 13551 Dimensions are shown in inches (millimeters). 2.50 (64) 52.00 (1321) TAUB-CA Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 12285 42-10 1 595 0.94 14015 42-10 1 615 1.05 14486 12823 42-15 1-1/2 645 1.21 15192 13620 11735 42-15 1-1/2 695 1.51 16370 14932 13299 10766 42-20 2 725 1.71 17077 15711 14166 12028 42-20 2 745 1.86 17548 16227 14727 12823 42-20 2 765 2.03 18019 16741 15283 13574 10734 42-30 3 790 2.23 18608 17381 15972 14374 11787 42-30 3 830 2.58 19550 18399 17064 15632 13600 42-30 3 870 2.97 20492 19412 18142 16844 15191 42-50 5 920 3.52 21670 20650 19468 18247 16844 11758 42-50 5 980 4.24 23083 22126 21042 19903 18719 15078 42-50 5 1040 5.04 24496 23594 22598 21533 20447 17596 12149 42-50 5 1070 5.54 25203 24326 23371 22338 21284 18780 14063 42-75 7-1/2 1105 6.1 26027 25178 24268 23268 22252 19938 16035 42-75 7-1/2 1145 6.78 26969 26150 25289 24324 23348 21205 18064 12465 42-75 7-1/2 1185 7.5 27912 27120 26305 25373 24435 22455 19684 15008 42-75 7-1/2 1220 8.17 28736 27967 27190 26285 25379 23527 21075 17119 42-100 10 1250 8.84 29443 28692 27941 27063 26179 24375 22191 18684 42-100 10 1280 9.48 30149 29416 28683 27838 26975 25217 23152 20191 42-100 10 1305 10.04 30738 30019 29300 28482 27636 25915 23946 21208 42-100 10 1345 11 31680 30983 30285 29509 28687 27023 25203 22811 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 18 TAUB-CA-48 Belt Drive ® 56.00 (1422) Specifications Max frpm = 1550 Outlet Velocity (fpm) = cfm / 17.10 ft2 Tip Speed = frpm x 12.56 Max Motor Frame Size = 254T Fan Tube Gauge = 10 ga. Windband Gauge = 20 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 865 lbs. (392 kg.) Recommended Roof Opening = 501/2 x 501/2 in. (1283 x 1283 mm) 76.75 (1949) 40.00 (1016) 42.75 (1086) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 12591 Steel Dampers: 16241 2.50 (64) Dimensions are shown in inches (millimeters). 58.00 (1473) TAUB-CA Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 12027 48-15 1-1/2 495 1.16 17450 15218 48-15 1-1/2 545 1.55 19213 17228 14765 10438 48-20 2 595 2.02 20975 19194 17098 14060 48-20 2 611 2.19 21539 19816 17798 15011 48-30 3 625 2.34 22033 20359 18393 15832 48-30 3 650 2.63 22914 21324 19447 17248 13774 48-30 3 680 3.02 23972 22474 20696 18676 15785 48-30 3 700 3.29 24677 23237 21520 19613 17007 48-50 5 740 3.89 26087 24746 23139 21442 19340 12097 48-50 5 770 4.37 27145 25856 24334 22719 20845 14694 48-50 5 800 4.91 28202 26962 25519 23981 22260 17135 48-50 5 825 5.39 29083 27881 26501 25023 23422 18814 12005 48-75 7-1/2 840 5.69 29612 28431 27087 25643 24113 19797 13010 48-75 7-1/2 880 6.53 31022 29895 28642 27283 25848 22163 16137 11661 48-75 7-1/2 920 7.47 32432 31354 30186 28886 27534 24429 19531 13261 48-75 7-1/2 950 8.19 33490 32445 31337 30078 28784 25860 21549 15265 48-100 10 970 8.66 34195 33172 32101 30869 29612 26803 22862 16766 48-100 10 990 9.26 34900 33898 32864 31656 30436 27739 24055 18601 48-100 10 1010 9.89 35605 34623 33624 32441 31255 28667 25233 20406 48-100 10 1030 10.49 36310 35347 34383 33222 32061 29588 26398 21932 48-150 15 1065 11.6 37544 36612 35680 34584 33461 31114 28336 24284 48-150 15 1100 12.8 38778 37876 36974 35938 34851 32597 30004 26487 48-150 15 1135 14 40012 39137 38263 37286 36233 34066 31650 28549 48-150 15 1170 15.4 41246 40397 39549 38628 37606 35523 33275 30576 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 19 TAUB-CA-54 Belt Drive ® 62.63 (1591) Specifications Max frpm = 1270 Outlet Velocity (fpm) = cfm / 21.39 ft2 Tip Speed = frpm x 14.13 Max Motor Frame Size = 256T Fan Tube Gauge = 10 ga. Windband Gauge = 18 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 1170 lbs. (531 kg.) Recommended Roof Opening = 561/2 x 561/2 in. (1422 x 1422 mm) 86.75 (2203) 44.00 (1118) 47.25 (1200) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 16005 Steel Dampers: 21425 Dimensions are shown in inches (millimeters). 2.50 (64) 64.00 (1626) TAUB-CA Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 54-20 2 475 2.24 28091 24924 20807 54-30 3 500 2.61 29569 26596 22883 54-30 3 525 3.03 31047 28251 24913 54-30 3 535 3.19 31639 28908 25714 54-50 5 575 3.99 34004 31519 28577 24812 54-50 5 600 4.53 35483 33136 30328 27005 21238 54-50 5 625 5.12 36961 34744 32059 29057 24702 54-75 7-1/2 645 5.62 38144 36012 33431 30673 26747 54-75 7-1/2 660 6.03 39031 36948 34453 31851 28256 54-75 7-1/2 685 6.74 40510 38502 36136 33638 30533 54-75 7-1/2 710 7.50 41988 40051 37804 35405 32598 21874 54-75 7-1/2 735 8.32 43466 41596 39460 37154 34631 26033 20534 54-100 10 750 8.84 44354 42520 40449 38196 35837 28127 54-100 10 765 9.39 45241 43443 41434 39232 36987 30191 54-100 10 780 9.95 46128 44365 42415 40263 38061 31746 54-100 10 805 10.9 47606 45898 44044 41970 39837 34273 22559 54-150 15 835 12.2 49380 47734 45989 43993 41946 37066 27973 54-150 15 865 13.6 51154 49565 47923 45997 44034 39550 32336 54-150 15 895 15.0 52929 51392 49847 47986 46102 41995 36078 24515 54-150 15 925 16.5 54703 53216 51730 49963 48154 44406 39121 29748 54-200 20 945 17.7 55885 54430 52975 51274 49511 45879 41118 33062 54-200 20 965 18.8 57068 55643 54218 52581 50854 47306 42869 35861 54-200 20 985 20.0 58251 56855 55459 53883 52192 48725 44530 38619 54-200 20 1000 21.0 59138 57763 56388 54857 53191 49783 45765 40271 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 20 TAUB-CA-60 Belt Drive ® 68.75 (1746) Specifications Max frpm = 950 Outlet Velocity (fpm) = cfm / 25.78 ft2 Tip Speed = frpm x 15.70 Max Motor Frame Size = 284T Fan Tube Gauge = 10 ga. Windband Gauge = 18 ga. Curb Cap = 10 ga. Approx. Weight (LM) = 1440 lbs. (653 kg.) Recommended Roof Opening = 621/2 x 621/2 in. (1588 x 1588 mm) 93.75 (2381) 48.13 (1223) 50.75 (1289) Minimum CFM required to open butterfly dampers: Aluminum Dampers: 18051 Steel Dampers: 24820 2.50 (64) Dimensions are shown in inches (millimeters). 70.00 (1778) TAUB-CA Performance Data Model Number Motor HP Fan RPM Max BHP CFM / Static Pressure in Inches WG 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM CFM CFM CFM CFM CFM CFM CFM 60-20 2 415 2.15 32356 27799 22312 60-30 3 440 2.59 34306 30030 25227 60-30 3 470 3.15 36645 32678 28356 22255 60-50 5 500 3.78 38984 35305 31273 26298 60-50 5 530 4.51 41323 37903 34129 29872 23864 60-50 5 555 5.21 43272 40049 36426 32686 27375 60-75 7-1/2 590 6.23 46001 43028 39593 36136 31920 34841 60-75 7-1/2 615 7.06 47950 45118 41826 38554 60-75 7-1/2 635 7.80 49509 46767 43596 40463 37134 26358 60-100 10 660 8.74 51458 48820 45800 42804 39641 30828 60-100 10 680 9.54 53018 50457 47560 44637 41602 33563 60-100 10 700 10.39 54577 52089 49310 46454 43542 36248 60-150 15 725 11.5 56526 54124 51483 48706 45940 39378 60-150 15 750 12.8 58476 56153 53643 50939 48309 42299 33844 60-150 15 775 14.2 60425 58178 55791 53155 50610 45170 37369 60-150 15 805 15.9 62764 60600 58354 55799 53343 48221 41418 60-200 20 835 17.7 65103 63017 60903 58440 56048 51164 45215 37127 60-200 20 860 19.3 67052 65027 63002 60625 58283 53586 48143 40892 60-200 20 885 21.1 69001 67033 65065 62799 60504 55984 51028 44293 60-250 25 910 23.0 70950 69037 67123 64962 62709 58359 53743 47633 60-250 25 930 24.5 72510 70637 68764 66684 64473 60223 55727 50131 60-250 25 950 26.0 74069 72236 70403 68400 66236 62060 57694 52484 Performance shown is for installation type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (bhp) does not include drive losses. 21 Axial Family & Applications ® Automotive Duty - Upblast Roof Ventilator Greenheck’s TAUB-CA Automotive Duty fan takes upblast roof ventilators to a new level. Increased material gauges combined with high standards in construction and component parts creates a quality, heavy-duty product capable of meeting the toughest demands. Standard Features: • Heavy-gauge steel housing, windband, dampers and curb cap • AMCA licensed air performance • “Air Handling Quality” bearings with L10 40,000 hour (L50 at 200,000 hours) bearing life • Electrostatically applied, industrial grade powder paint • External lube lines • Drives sized for a minimum of 150% of the motor horsepower • Cast aluminum hub and airfoil blades balanced to grade G6.3 • Adjustable motor pivot base for belt tensioning Standard Construction: The housing, bearing support and motor base are constructed of structural members to prevent vibration and rigidly support the shaft, bearings and motor. Curb caps are welded to the fan housing to provide a leak resistant seal. Also incorporated into the curb cap design is an integral venturi inlet with a prepunched mounting flange. Windbands have reinforced edges for rigidity. Optional Accessories: • • • • • • • • • 22 Aluminum and spark resistant construction NEMA 3R heavy-duty disconnect switches with optional pigtail Complete line of corrosion resistant coatings UL/cUL 705 OSHA inlet and outlet guards Felt shaft seal Access door - bolted or hinged Welded roof curbs Fusible link damper lifters ® Spark Resistant - Inline Cast Aluminum Propeller TBI-CA and TDI axial fans are a practical choice for inline applications involving clean air or air containing volatile compounds. These fans can be used in either ducted or unducted applications. Cast aluminum hub and airfoil blades provide spark resistant construction and are suited for 1 to 3 inches wg (249 - 747 Pa) of static pressure. Three levels of construction provide efficient and economical selections for reliable performance in commercial and industrial applications. Typical applications include: • General exhaust, supply or return air • Industrial or commercial space ventilation • Fume hood exhaust • Paint booth exhaust • Emergency smoke exhaust Levels four and five available in roof upblast style. Lower Pressures TAUB-CA Higher Pressures TAUD TDI TBI-CA Level 3 TBI-CA TDI Level 4 TBI-CA Level 5 TDI High Temperature or Emergency Smoke Control - Steel Propeller Model TBI-FS inline fans are the ideal choice for installations for high temperature applications, continuous duty or emergency use. Designed for commercial and industrial applications for air volumes up to 77,000 cfm (130,000 m3/hr) and moderate pressures to 4 inches wg (996 Pa). TBI-FS models have a continuously welded housing and are belt driven with motors and drives out of the airstream. All propellers are constructed with airfoil blades that are continuously welded to heavy-duty hubs to ensure long life in the harshest applications. Typical applications include: • General exhaust, supply or return air • Industrial space and warehouse ventilation • UL/cUL Listed for emergency heat and smoke removal • High temperature process ventilation Lower Pressures TAUB-L/H Operating Temperature °F °C Time Duration Hours Continuous Duty Standard Construction 180 82 Inline 400 204 Continuous Continuous Roof Upblast 500 260 Continuous 260 300 400 538 149 399 538 4 1 2 1 5 4 0.25 Emergency Smoke Control HT-II HT-III HT-UL • UL/cUL Listed 500 572 752 1000 300 750 1000 Higher Pressures TBI-FS Level 3 TBI-FS Level 4 TBI-FS Level 5 23 Specifications General Tube Axial Roof Mount Roof mount fans shall be of the tube axial type with cast aluminum airfoil propellers. Fan tube, wind band, and curb cap shall be constructed of heavy-gauge steel with prepunched mounting flange and an integral venturi inlet. Curb cap shall have prepunched mounting holes. Steel housings and structural components to be coated with Permatector™, an electrostatically applied thermosetting polyester urethane. Minimum coating thickness to be 2 mils. Fan performance shall be based on tests conducted in accordance with AMCA Standard 210. All fans shall be licensed to bear the AMCA Certified Ratings Seal for Air Performance. Model TAUD Tube Axial Roof Mount, Direct Drive Propellers shall be cast aluminum airfoil design. A tapered bushing shall lock the propeller to the motor shaft. Propellers to be dynamically balanced. Hubs shall be two piece aluminum castings that securely lock the blades in place. Fans shall be model TAUD as manufactured by Greenheck of Schofield, Wisconsin, USA. Model TAUB-CA Tube Axial Roof Mount, Belt Drive Propellers shall be cast aluminum airfoil design. A tapered bushing shall lock the propeller to the fan shaft. Propellers to be dynamically balanced. Hubs shall be two piece aluminum castings that securely lock the blades in place. Bearings shall be cast iron pillow block, grease lubricated, and self-aligning. Bearings shall be Air Handling Quality and tested for reduced swivel torque, bore size, noise, and vibration. Bearings shall be selected for an L10 life, per ABMA standards, in excess of 40,000 hours at maximum operating speed. Turned, precision ground and polished steel shafts shall be sized so the first critical speed is at least 25% over the maximum operating speed for each level of construction. Fans shall be model TAUB-CA as manufactured by Greenheck of Schofield, Wisconsin, USA. Building Value in Air Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative airrelated equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet dependable operation they experience long after the construction project ends. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Prepared to Support Green Building Efforts TAUD TAUB-CA Rev 2 September 2002 SP Copyright © 2014 Greenheck Fan Corp.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Instance ID : uuid:13717f07-1bc0-4483-b148-11f5037f52e7 Original Document ID : adobe:docid:indd:285b775b-0a75-11de-8257-eb01dbde2ad6 Document ID : xmp.id:32b40908-040f-4246-9c86-20b1401c6818 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:2688d9ea-1be7-5d43-8ff6-8afae94f9cdd Derived From Document ID : xmp.did:ed1516e1-5acd-ae44-8519-258104bc8a08 Derived From Original Document ID: adobe:docid:indd:285b775b-0a75-11de-8257-eb01dbde2ad6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:04:04 08:22:45-05:00 Create Date : 2014:04:04 08:22:45-05:00 Modify Date : 2014:07:02 10:57:23-05:00 Metadata Date : 2014:07:02 10:57:23-05:00 Creator Tool : Adobe InDesign CC (Windows) Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 24 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools