TO 252 2 Leaded Package Dimensions
User Manual:
Open the PDF directly: View PDF .
Page Count: 1
1
©2002 Fairchild Semiconductor Corporation February 2002, Rev A
b2
E
D
L3
b1
b
12
A
L
c
SEATING
BACK VIEW
H1A1
b3
e1J1
L1
TERM. 3 0.265
MINIMUM PAD SIZE RECOMMENDED FOR
SURFACE-MOUNTED APPLICATIONS
(6.7)
0.265 (6.7
)
0.070 (1.8)
0.118 (3.0)
0.063 (1.6) TYP
0.090 (2.3) TYP
PLANE
SYMBOL
INCHES MILLIMETERS
NOTESMIN MAX MIN MAX
A 0.086 0.094 2.19 2.38 -
A10.018 0.022 0.46 0.55 3, 4
b 0.028 0.032 0.72 0.81 3, 4
b10.033 0.040 0.84 1.01 3
b20.205 0.215 5.21 5.46 3, 4
b30.190 - 4.83 - 2
c 0.018 0.022 0.46 0.55 3, 4
D 0.270 0.290 6.86 7.36 -
E 0.250 0.265 6.35 6.73 -
e10.180 BSC 4.57 BSC 6
H10.035 0.045 0.89 1.14 -
J10.040 0.045 1.02 1.14 -
L 0.100 0.115 2.54 2.92 -
L10.020 - 0.51 - 3, 5
L30.170 - 4.32 - 2
NOTES:
1. No current JEDEC outline for this package.
2. L3 and b3 dimensions establish a minimum mounting surface for
terminal 3.
3. Dimension (without solder).
4. Add typically 0.002 inches (0.05mm) for solder plating.
5. L1 is the terminal length for soldering.
6. Position of lead to be measured 0.090 inches (2.28mm) from bottom
of dimension D.
7. Controlling dimension: Inch.
8. Revision 8 dated 5-99.
TO-252
2 LEAD SURFACE MOUNT JEDEC TO-252 PLASTIC PACKAGE
(FOR RECTIFIERS ONLY)