AT Command Set TOPEX SIEMENS Module

User Manual: TOPEX AT SIEMENS module Alloy Computer Products - Australia - s

Open the PDF directly: View PDF PDF.
Page Count: 204

DownloadAT Command Set TOPEX SIEMENS Module
Open PDF In BrowserView PDF
Siemens Cellular Engines

TC35 Module
TC37 Module
TC35 Terminal

Version: 04.00
DocID: TC3X_ATC_01_V04.00

AT Command Set

Document Name:

AT Command Set
Siemens Cellular Engines

Version:
Date:
Doc Id:
Status:

04.00
May 29, 2002
TC3X_ATC_01_V04.00
Released

General note
With respect to any damages arising in connection with the described product or this document,
Siemens shall be liable according to the General Conditions on which the delivery of the described
product and this document are based.
This product is not intended for use in life support appliances, devices or systems where a malfunction
of the product can reasonably be expected to result in personal injury. Siemens AG customers using
or selling this product for use in such applications do so at their own risk and agree to fully indemnify
Siemens for any damages resulting from illegal use or resale.
Applications incorporating the described product must be designed to be in accordance with the
technical specifications provided in these guidelines. Failure to comply with any of the required
procedures can result in malfunctions or serious discrepancies in results.
Furthermore, all safety instructions regarding the use of mobile technical systems, including GSM
products, which also apply to cellular phones must be followed.
Handheld applications such as mobile phones or PDAs incorporating the described product must be in
accordance with the guidelines for human exposure to radio frequency energy. The Specific
Absorption Rate (SAR) of the application must be evaluated and approved to be compliant with
national and international safety standards or directives.
Subject to change without notice at any time.

Copyright
Copying of this document and giving it to others and the use or communication of the contents thereof,
are forbidden without express authority. Offenders are liable to the payment of damages. All rights
reserved in the event of grant of a patent or the registration of a utility model or design.
Copyright © Siemens AG 2001

TC3X_ATC_01_V04.00

Page 2 of 204

29.05.2002

AT Command Set

Contents
0

Version History .............................................................................................7

1

Introduction .................................................................................................10

1.1
1.2
1.3
1.4
1.4.1
1.4.2
1.4.3
1.5
1.6
1.6.1
1.6.2

Scope of the document ...........................................................................................................10
Supported product versions and related documents ..............................................................10
Conventions ............................................................................................................................11
AT command syntax ...............................................................................................................11
Using parameters....................................................................................................................11
Combining AT commands on the same command line ..........................................................12
Entering successive AT commands on separate lines ...........................................................12
Supported character sets ........................................................................................................13
Flow control .............................................................................................................................14
Software flow control (XON/OFF flow control) ........................................................................14
Hardware flow control (RTS/CTS flow control) .......................................................................14

2

Standard V.25ter AT Commands ...............................................................15

2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
2.13
2.14
2.15
2.16
2.17
2.18
2.19
2.20
2.21
2.22
2.23
2.24
2.25
2.26
2.27
2.28
2.29
2.30
2.31
2.32
2.33
2.34
2.35
2.36
2.37
2.38

A/ Repeat previous command line .........................................................................................15
+++ Switch from data mode to command mode ....................................................................15
AT\Qn Flowcontrol .................................................................................................................16
ATA Answer a call..................................................................................................................16
ATD Mobile originated call to dial a number ..........................................................................17
ATD> Originate call to phone number  in memory  ..........................18
ATD> Originate call to phone number selected from active memory..............................20
ATD> Originate call to phone number in memory with corresponding field ..................21
ATDI Mobile originated call to dialable ISDN number  ....................................................22
ATDL Redial last telephone number used .............................................................................23
ATE Enable command echo ..................................................................................................24
ATH Disconnect existing connection .....................................................................................24
ATI Display product identification information........................................................................25
ATI[value] Display additional identification information..........................................................25
ATL Set monitor speaker loudness........................................................................................26
ATM Set monitor speaker mode ............................................................................................26
ATO Switch from command mode to data mode...................................................................26
ATQ Set result code presentation mode................................................................................27
ATP Select pulse dialling .......................................................................................................27
ATS0 Set number of rings before automatically answering the call ......................................27
ATS2 Escape code sequence................................................................................................28
ATS3 Write command line termination character ..................................................................28
ATS4 Set response formatting character...............................................................................28
ATS5 Write command line editing character..........................................................................29
ATS6 Set pause before blind dialling.....................................................................................29
ATS7 Set number of seconds to wait for connection completion ..........................................30
ATS8 Set number of seconds to wait for comma dial modifier ..............................................30
ATS10 Set disconnect delay after indicating the absence of data carrier .............................31
ATS18 Extended error report.................................................................................................31
ATT Select tone dialling .........................................................................................................31
ATV Set result code format mode..........................................................................................32
ATX Set CONNECT result code format and call monitoring..................................................32
ATZ Set all current parameters to user defined profile ..........................................................33
AT&C Set circuit Data Carrier Detect (DCD) function mode..................................................33
AT&D Set circuit Data Terminal Ready (DTR) function mode ...............................................34
AT&F Set all current parameters to manufacturer defaults ...................................................34
AT&S Set circuit Data Set Ready (DSR) function mode........................................................35
AT&V Display current configuration .......................................................................................36

TC3X_ATC_01_V04.00

Page 3 of 204

29.05.2002

AT Command Set

2.39
2.40
2.41
2.42
2.43
2.44
2.45
2.46
2.46.1

AT&W Store current configuration to user defined profile .....................................................37
AT+GCAP Request complete TA capabilities list ..................................................................38
AT+GMI Request manufacturer identification........................................................................38
AT+GMM Request TA model identification............................................................................38
AT+GMR Request TA revision identification of software status ............................................39
AT+GSN Request TA serial number identification(IMEI).......................................................39
AT+ILRR Set TE-TA local rate reporting ................................................................................40
AT+IPR Set fixed local rate.....................................................................................................41
Autobauding ............................................................................................................................42

3

AT Commands for FAX...............................................................................43

3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12
3.13
3.14
3.15
3.16
3.17
3.18
3.19
3.20
3.21
3.22
3.23
3.24
3.25
3.26
3.27

AT+FBADLIN Bad Line Threshold .........................................................................................43
AT+FBADMUL Error Threshold Multiplier..............................................................................44
AT+FBOR Query data bit order .............................................................................................44
AT+FCIG Query or set the Local polling id ............................................................................45
AT+FCLASS Fax: Select, read or test service class .............................................................45
AT+FCQ Copy Quality Checking ...........................................................................................46
AT+FCR Capability to receive................................................................................................46
AT+FDCC Query or set capabilities.......................................................................................47
AT+FDFFC Data Compression Format Conversion ..............................................................48
AT+FDIS Query or set session parameters...........................................................................49
AT+FDR Begin or continue phase C data reception..............................................................50
AT+FDT Data Transmission ..................................................................................................50
AT+FET End a page or document .........................................................................................51
AT+FK Kill operation, orderly FAX abort................................................................................51
AT+FLID Query or set the Local Id setting capabilities .........................................................51
AT+FMDL Identify Product Model..........................................................................................52
AT+FMFR Request Manufacturer Identification ....................................................................52
AT+FOPT Set bit order independently...................................................................................52
AT+FPHCTO DTE Phase C Response Timeout ...................................................................53
AT+FREV Identify Product Revision ......................................................................................53
AT+FRH Receive Data Using HDLC Framing .......................................................................53
AT+FRM Receive Data ..........................................................................................................54
AT+FRS Receive Silence ......................................................................................................54
AT+FTH Transmit Data Using HDLC Framing ......................................................................54
AT+FTM Transmit Data .........................................................................................................55
AT+FTS Stop Transmission and Wait ...................................................................................55
AT+FVRFC Vertical resolution format conversion .................................................................56

4

AT Commands originating from GSM 07.07 .............................................57

4.1
4.2
4.3
4.4
4.5
4.6
4.6.1
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
4.18

AT+CACM Accumulated call meter (ACM) reset or query ....................................................57
AT+CALA Set alarm time.......................................................................................................58
AT+CAMM Accumulated call meter maximum (ACMmax) set or query................................61
AT+CAOC Advice of Charge information ..............................................................................62
AT+CBST Select bearer service type ....................................................................................63
AT+CCFC Call forwarding number and conditions control....................................................64
Examples: Call forwarding ......................................................................................................65
AT+CCLK Real Time Clock ...................................................................................................67
AT+CEER Extended error report ...........................................................................................68
AT+CFUN Set phone functionality .........................................................................................69
AT+CGMI Request manufacturer identification ......................................................................71
AT+CGMM Request model identification...............................................................................71
AT+CGMR Request revision identification of software status ...............................................71
AT+CGSN Request product serial number identification (IMEI) identical to GSN ................72
AT+CHLD Call hold and multiparty .........................................................................................72
AT+CHUP Hang up call .........................................................................................................73
AT+CIMI Request international mobile subscriber identity....................................................73
AT+CLCC List current calls of ME .........................................................................................74
AT+CLCK Facility lock ...........................................................................................................75

TC3X_ATC_01_V04.00

Page 4 of 204

29.05.2002

AT Command Set

4.18.1
4.18.2
4.18.3
4.19
4.20
4.21
4.22
4.23
4.24
4.24.1
4.25
4.26
4.27
4.28
4.29
4.30
4.31
4.31.1
4.32
4.33
4.34
4.35
4.36
4.37
4.38
4.39
4.40
4.41
4.42
4.43
4.44
4.45
4.46
4.47

Examples: Enabling / disabling PIN 1 authentication .............................................................77
Examples: Phone lock.............................................................................................................77
Examples: Call barring ............................................................................................................79
AT+CLIP Calling line identification presentation....................................................................81
AT+CLIR Calling line identification restriction (by *# sequence) ...........................................82
AT+CLVL Loudspeaker volume level ....................................................................................83
AT+CMEE Report mobile equipment error ............................................................................84
AT+CMUT Mute control .........................................................................................................85
AT+CMUX Enter multiplex mode ...........................................................................................86
Restricted use of AT commands in Multiplex mode................................................................87
AT+COPN Read operator names ..........................................................................................89
AT+COPS Operator selection................................................................................................90
AT+CPAS Mobile equipment activity status ..........................................................................92
AT+CPBR Read current phonebook entries..........................................................................93
AT+CPBS Select phonebook memory storage......................................................................94
AT+CPBW Write phonebook entry ........................................................................................95
AT+CPIN Enter PIN ...............................................................................................................96
What to do if PIN or password authentication fails? ...............................................................99
AT+CPIN2 Enter PIN2 .........................................................................................................101
AT+CPUC Price per unit and currency table .......................................................................103
AT+CPWD Change password .............................................................................................104
AT+CR Service reporting control .........................................................................................106
AT+CRC Set Cellular Result Codes for incoming call indication.........................................107
AT+CREG Network registration ...........................................................................................108
AT+CRLP Select radio link protocol param. for orig. non-transparent data call..................110
AT+CRSM Restricted SIM access .......................................................................................111
AT+CSCS Set TE character set...........................................................................................112
AT+CSNS Single Numbering Scheme ................................................................................113
AT+CSQ Signal quality ........................................................................................................114
AT+CSSN Supplementary service notifications...................................................................115
AT+CUSD Unstructured supplementary service data .........................................................116
AT+VTD= Tone duration................................................................................................117
AT+VTS DTMF and tone generation ( in {0-9, *, #, A, B, C, D}) .............................118
AT+WS46 Select wireless network .......................................................................................119

5

AT commands originating from GSM 07.05 for SMS .............................120

5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
5.14
5.15
5.16

AT+CMGC Send an SMS command ...................................................................................120
AT+CMGD Delete SMS message........................................................................................121
AT+CMGF Select SMS message format .............................................................................121
AT+CMGL List SMS messages from preferred store ..........................................................122
AT+CMGR Read SMS message .........................................................................................125
AT+CMGS Send SMS message..........................................................................................128
AT+CMGW Write SMS message to memory.......................................................................130
AT+CMSS Send SMS message from storage.....................................................................132
AT+CNMA New SMS message acknowledge to ME/TE, only phase 2+ ............................133
AT+CNMI New SMS message indications ..........................................................................134
AT+CPMS Preferred SMS message storage ......................................................................137
AT+CSCA SMS service centre address ..............................................................................138
AT+CSCB Select cell broadcast messages.........................................................................139
AT+CSDH Show SMS text mode parameters .....................................................................140
AT+CSMP Set SMS text mode parameters.........................................................................141
AT+CSMS Select Message Service ....................................................................................142

6

Siemens defined AT commands for enhanced functions .....................143

6.1
6.2
6.3
6.4
6.5

AT+CXXCID Display card ID (identical to AT^SCID)...........................................................143
AT^MONI Monitor idle mode and dedicated mode ..............................................................144
AT^MONP Monitor neighbour cells......................................................................................146
AT^SACM Advice of charge and query of ACM and ACMmax ...........................................147
AT^SBC Battery charging / discharging and charge control................................................148

TC3X_ATC_01_V04.00

Page 5 of 204

29.05.2002

AT Command Set

6.6
6.7
6.8
6.9
6.10
6.11
6.12
6.13
6.14
6.15
6.16
6.17
6.18
6.19
6.20
6.21
6.22
6.23
6.24
6.25
6.26
6.27
6.28
6.29
6.30
6.31
6.32
6.33
6.34
6.35
6.36
6.37
6.38
6.39
6.40

AT^SCID Display SIM card identification number................................................................151
AT^SCKS Set SIM connection presentation mode and query SIM connection status ........152
AT^SCNI List Call Number Information ...............................................................................153
AT^SCTM Set critical operating temperature presentation mode or query temperature.....154
AT^SDLD Delete the “last number redial“ memory..............................................................156
AT^SHOM Display Homezone.............................................................................................156
AT^SLCD Display Last Call Duration...................................................................................156
AT^SLCK Facility lock ..........................................................................................................157
AT^SMGL List SMS messages from preferred storage.......................................................158
AT^SMGO Set or query SMS overflow presentation mode or query SMS overflow ...........159
AT^SMGR Read SMS message without set to REC READ ................................................160
AT^SMONC Cell Monitoring ................................................................................................161
AT^SMSO Switch off mobile station ....................................................................................162
AT^SM20 Set M20 Compatibility .........................................................................................162
AT^SNFD Set audio parameters to manufacturer default values........................................163
AT^SNFI Set microphone path parameters .........................................................................163
AT^SNFM Mute microphone................................................................................................164
Audio programming model ....................................................................................................164
AT^SNFO Set audio output (= loudspeaker path) parameter..............................................165
AT^SNFPT Call progress tones ..........................................................................................166
AT^SNFS Select audio hardware set...................................................................................167
AT^SNFV Set loudspeaker volume......................................................................................168
AT^SNFW Write audio setting in non-volatile store .............................................................168
AT^SPBC Search the first entry in the sorted telephone book ............................................169
AT^SPBG Read entry from active telephone book via sorted index ...................................170
AT^SPBS Steps the selected phonebook alphabetically.....................................................171
AT^SPIC Display PIN counter..............................................................................................172
AT^SPLM Read the PLMN list .............................................................................................173
AT^SPLR Read entry from the preferred operators list .......................................................174
AT^SPLW Write an entry to the preferred operators list......................................................175
AT^SPWD Change password for a lock ..............................................................................176
AT^SSCONF SMS Configuration........................................................................................177
AT^SSDA Set Display Availability.......................................................................................178
AT^SSYNC Configure SYNC Pin.........................................................................................179
AT^STCD Display Total Call Duration .................................................................................180

7

APPENDIX .................................................................................................181

7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
7.1.6
7.1.7
7.1.8
7.1.9
7.1.10
7.1.11

Summary of ERRORS and Messages..................................................................................181
Summary of CME ERRORS related to GSM 07.07..............................................................181
Summary of CMS ERRORS related to GSM 07.05..............................................................183
Summary of Unsolicited Result Codes (URC) ......................................................................185
Result codes .........................................................................................................................187
Cause Location ID for the extended error report (AT+CEER) ..............................................187
GSM release cause for L3 Radio Resource (RR) (AT+CEER) ...........................................188
SIEMENS release cause for L3 Radio Resource (RR) (AT+CEER) ...................................188
GSM release cause for Mobility Management (MM) (AT+CEER) ........................................189
SIEMENS release cause for L3 Mobility Management (MM) (AT+CEER) ...........................189
GSM release cause for L3 Call Control (CC) (AT+CEER) ...................................................190
SIEMENS release cause for L3 Call Control (CC) and Mobile Station Manager (MSM)
(AT+CEER) ...........................................................................................................................191
SIEMENS release cause for L3 Advice of Charge (AOC) (AT+CEER) ...............................192
GSM Release cause for Supplementary Service call (AT+CEER).......................................192
SIEMENS release cause for Call-related Supplementary Services (CRSS) (AT+CEER)...193
Summary of PIN requiring AT Commands............................................................................194
AT commands available before entering the SIM PIN..........................................................196
Standard GSM service codes ...............................................................................................198
Additional notes on ^SCCFC, ^SCCWA, ^SCLCK ...............................................................200
GSM and UCS2 alphabet tables...........................................................................................202

7.1.12
7.1.13
7.1.14
7.2
7.3
7.4
7.4.1
7.5

TC3X_ATC_01_V04.00

Page 6 of 204

29.05.2002

AT Command Set

0 Version History
This chapter reports modifications and improvements over previous versions of the document.
"AT Command Set" Version TC3x-ATC-01-V03.10=> TC3x5-ATC-01-04.00
Chapter

Page

AT command

What is new

1.5

13

Character sets

1.6
1.4.2

14
12

Flow control
Any command

2.3

16

AT\Qn

2.21
4.2

28
58f

ATS2
AT+CALA

4.6 and
4.6.1
4.18
4.18.3

64f
65
75

AT+CCFC

Chapter revised and associated character set tables
in Chapter 7.5 updated.
How to use flow control.
Maximum length of command line buffer added. Note
regarding on sequential order of concatenated
commands added.
Further details added: Using RTS/CTS handshake.
Restoring AT\Q settings.
Command description added.
Statement regarding the URC +CALA  revised:
If autobauding is active neither the URC +CALA nor
the individual  will appear.
New  parameters added.
Further examples added.
New  parameters added.
Under parameter “PS” lock, the following statement
has been removed: “ME may remember numbers of
previously used cards.”
Further examples for call barring added.
Fax specific AT commands are not usable.
AT\Q3 (hardware flow control) is recommended.
Minimum bit rate set with AT+IPR: 4.8 kbps
Timing algorithm of incorrect password corrected
Note added: Realistic BER values can be obtained
only if there is a call in progress.
Command syntax corrected: Parameter  is
mandatory.
Further notes regarding the usage of AT+CLVL and
AT^SNFV added.
Further notes regarding the usage of AT+MUT and
AT^SNFM added.
Chapter revised.
Note regarding AT^SSCONF added.

AT+CLCK

4.24.1

79
87

AT+CMUX

4.31.1
4.42

99
114

AT+CPIN
AT+CSQ

4.5

63

AT+CBST

4.21

83

AT+CLVL

4.23

85

AT+CMUT

4.39
5.4
5.2
5.10

111
122
121
134

AT+CRSM
AT+CMGL
AT+CMGR
AT+CNMI

5.7

130

AT+CMGW

TC3X_ATC_01_V04.00

Note regarding AT^SSCONF added.
Note regarding the handling of Class 0 short
messages added.
Parameter  corrected (only required for PDU,
not for text mode).
Result code after failure of storing a message to the
SIM card (ME returns OK).
Statement about sending e-mails via SMS corrected:
If not recognized by provider, @ may be replaced with
“*”.
Page 7 of 204

29.05.2002

AT Command Set

6.2

144ff

AT^MONI

6.3

146

At^MONP

6.7
6.13
6.17
6.25
6.20, 6.22,
6.24 – 6.28
6.37

152
157
161
166
163ff

AT^SCKS
AT^SLCK
AT^SMONC
AT^SNFPT
AT^SNF…

177

AT^SSCONF

6.38
7.1.2

178
183f

7.1.4
7.1.5

187
187

7.1.11

191

7.4
7.4.1
7.3

198
200
196

Examples on page 144 updated.
 and  explained in greater detail
References for 3GPP TS 05.05 and 05.08 added
Frequency hopping will now be indicated with “h”
(instead of the previously used “0”.
Notes modified: If during a connection the radio cell is
changed, the parameters PWR and RXLev of the
‘Serving Cell’ part will not be updated.
Statement regarding RING line revised.
Statement regarding different values of identical cell
monitoring
parameters
(used
for
AT^MONI,
AT^MONP and AT^SMONC) added.
 and  explained in greater detail
Notes modified: During a connection new neighbour
cells can be added, but their parameters C1 and C2
will be updated after the call.
Statement regarding RING line revised.
Notes regarding empty SIM card tray corrected.
New  parameters added.
New AT command: Cell monitoring
New AT command: Switch on / off Call Progress tones
All Chapters revised.

New AT command: Configuring recipient address
parameters in SMS result codes and in +CDS URCs.
AT^SSDA
New AT command: Set display availability
CMS errors
List of codes revised: Deleted unnecessary codes.
Note and example added: Mapping of CME and CMS
errors if SIM PIN authentication has not been done.
Result codes
“Connect 14400/RLP” added.
Location ID for List of codes revised: Deleted unnecessary codes.
AT+CEER
Release cause Notification 300 and note regarding Location ID
for call control
added.
*# codes
Abbreviations explained in greater detail.
Further examples added.
AT+VTS
Added to List of PIN1 independent AT commands

"AT Command Set" Version TC3x-ATC-01-V03.00=> TC3x5-ATC-01-03.10
Chapter

Page

AT command

What is new

1.4.2

12

2.13
2.37
2.20
2.26
2.46
2.46.1
3

25
35
27
30
41
42
43

Any command
AT+IPR
ATI[value]
AT&S
ATS0
ATS7
AT+IPR
AT+IPR
Fax commands

Maximum length of command line buffer added.
To be used standalone.
Only value 9 supported
2 removed
Notes added
Notes added
Recommendation added: To be used standalone.
List of bit rates detectable in autobaud mode
Note added: Autobauding recommended when using
standard PC Fax programs

TC3X_ATC_01_V04.00

Page 8 of 204

29.05.2002

AT Command Set

4.2

58

4.5
4.6
4.7

63
64
67

4.9
4.15
4.18

69
73
75

4.22
4.24
4.24.1
4.26
4.28
4.31 / 4.31.1

84
86
87
90
93
96 / 99

4.32
4.34
4.37
5.15

101
104
108
141

6.5

148

6.7
6.19
7.1.5- 7.1.14
7.1.3
7.2 / 7.3

152
162
181 - 193
185
194/196

TC3X_ATC_01_V04.00

AT+CALA

Alarm mode not applicable to TC35 Terminal.
RTC initialization after wake-up into Alarm mode
described.
AT+CBST
Transmission rate 14400 bps now supported.
AT+CCFC
Description revised, examples added
AT+CCLK
RTC initialization after wake-up into Alarm mode
described
AT+CFUN
Chapter revised
AT+CHUP
Note added: AT+CHUP implemented like ATH
AT+CLCK
Description revised, examples for phone security lock
types and call barring added
AT+CMEE
Setting not saved when ME is powered down
AT-CMUX
Overview on Multiplex mode updated
AT+CMUX
Restrictions on Multiplex mode updated
AT+COPS
Chapter revised
AT+CPBR
Description revised, examples added
AT+CPIN
Description revised. Summary of actions to be taken
after authentication failure
AT+CPIN2
Description revised, examples added
AT+CPWD
Description revised, examples added
AT+CREG
Description revised, examples added
AT+CSMP
Command
syntax
corrected,
first
parameter
mandatory
AT^SBC
Default setting of  described
Automatic shutdown explained in more detail
AT^SCKS
URC not stored when ME is powered down
AT^M20
Description revised
Several AT+CEER location Ids and release causes added
URCs
Further explanations relating to URCs
Usability of AT commands with or without PIN authentication: Both lists
updated

Page 9 of 204

29.05.2002

AT Command Set

1 Introduction
1.1

Scope of the document

This document presents the AT Command Set for the Siemens cellular engines
TC35 Module
TC37 Module
TC35 Terminal
The AT commands detailed in this document are generally supported by all products. Where
differences occur, they are noted in the chapter that refers to the command. In the present version, the
only exceptions concern the following commands:
Table 1: Product specific use of AT commands
AT command
AT+CALA, Chapter 4.2

TC35 / TC37 Modules
TC35 Terminal
Alarm mode and reminder call fully Does not support Alarm mode.
applicable
Please ignore any information
relating to the subject.
The reminder call can be used as
described.

AT^SSYNC, Chapter 6.39

SYNC pin may be assigned
different functions:  0 or 1.

SYNC pin supports only =1
(LED status).

AT^SBC, Chapter 6.5

All functions fully applicable

Command not applicable.

1.2

Supported product versions and related documents

Please note that TC35, TC37 Modules and TC35 Terminal are using the same firmware, referred to as
TC35. The present AT Command Set applies to all products based on the TC35 software version
04.00.
Related documents
[1] TC35 / TC37 Hardware Interface Description (applies to TC35 and TC37)
[2] TC3x Release Notes related to TC35 software version 04.00 (applies to TC35, TC37 and TC35T)
[3] TC3x Multiplexer User's Guide (applies to TC35, TC37 and TC35T)
[4] Application Note 16: Updating TC35 Firmware (applies to TC35, TC37 and TC35T)
[5] TC35 Terminal Hardware Interface Description (applies to TC35T)
[6] TC35 MC35 Terminal User's Guide (applies to TC35T and MC35T)
[7] Application Note 02: Audio Interface (applies to TC35, TC37 and TC35T)
Prior to using TC35 /TC37 or TC35T or upgrading to a new firmware release, be sure to carefully read
the latest product information provided in the Release Notes.

To visit the Siemens Website you can use the following link:
http://www.siemens.com/wm

TC3X_ATC_01_V04.00

Page 10 of 204

29.05.2002

AT Command Set

1.3

Conventions

Throughout the document, the GSM engines are referred to as ME (Mobile Equipment), MS (Mobile
Station), TA (Terminal Adapter), DCE (Data Communication Equipment) or facsimile DCE (FAX
modem, FAX board). When the Siemens product names are required to distinguish the two models,
TC3x is short for the engine type and TC35T for the terminal.
To control your GSM engine you can simply send AT Commands via its serial interface. The
controlling device at the other end of the serial line is referred to as TE (Terminal Equipment), DTE
(Data Terminal Equipment) or plainly ´the application´ (probably running on an embedded system).

1.4

AT command syntax

The "AT" or "at" prefix must be set at the beginning of each command line. To terminate a command
line enter .
Commands are usually followed by a response that includes “”.
Throughout this document, only the responses are presented,  are omitted intentionally.
Table 2: Types of AT commands and responses
Test command

AT+CXXX=?

Read command

AT+CXXX?

Write command
Execution command

AT+CXXX=<...>
AT+CXXX

The mobile equipment returns the list of parameters and
value ranges set with the corresponding Write command
or by internal processes.
This command returns the currently set value of the
parameter or parameters
This command sets user-definable parameter values.
The execution command reads non-variable parameters
affected by internal processes in the GSM engine.

1.4.1 Using parameters
· Default parameters are underlined throughout this document.
· Optional parameters are enclosed in square brackets. If optional parameters are omitted, the
current settings are used until you change them.
· Optional parameters or subparamters can be omitted unless they are followed by other
parameters. If you want to omit a parameter in the middle of a string it must be replaced by a
comma. Example:
AT+CPBW=,,, writes a phonebook entry to the first free memory location.
AT+CPBW=,,, writes a phonebook entry to the memory location
specified by .
· When the parameter is a character string, e.g.  or , the string must be enclosed in
quotation marks, e.g. "Charlie Brown" or "+49030xxxx". Symbols within quotation marks will be
recognized as strings.
· All spaces will be ignored when using strings without quotaton marks.
· It is possible to omit the leading zeros of strings which represent numbers.
· In case of using V.25ter commands without giving an optional parameter, its value is assumed to
be 0.

TC3X_ATC_01_V04.00

Page 11 of 204

29.05.2002

AT Command Set

1.4.2 Combining AT commands on the same command line
You may enter several AT commands on the same line. This eliminates the need to type the "AT" or
"at" prefix before each command. Instead, it is only needed once at the beginning of the command
line. Use a semicolon as command delimiter.
The command line buffer accepts a maximum of 391 characters. If this number is exceeded none of
the commands will be executed and TA returns ERROR.
The table below lists the AT commands you cannot enter together with other commands on the same
line. Otherwise, the responses may not be in the expected order.
Table 3: Illegal combinations of AT commands
V.25ter commands
GSM 7.07 commands
GSM 7.05 commands (SMS)
Commands starting with AT&
AT+IPR

With
With
-------

FAX commands, Prefix AT+F
Siemens commands, Prefix AT^S
To be used standalone
To be used standalone
To be used standalone

Note: Generally, appending the same or mixed AT commands should be avoided. If nevertheless
you need to do enter several commands on the same line, note that the number of subsequent
commands is limited.

1.4.3 Entering successive AT commands on separate lines
When you enter a series of AT commands on separate lines, leave a pause between the preceding
and the following command until OK appears. This avoids sending too many AT commands at a time
without waiting for a response for each.

TC3X_ATC_01_V04.00

Page 12 of 204

29.05.2002

AT Command Set

1.5

Supported character sets

The ME supports two character sets: GSM 03.38 (7 bit, also referred to as SMS alphabet) and UCS2
(16 bit, refer to ISO/IEC 10646). See Chapter 4.40 for information about selecting the character set.
Character tables are provided in Chapter 7.5.
Due to the constraints described below it is recommended to prefer the USC2 alphabet in any external
application.
If the GSM alphabet is selected all characters sent over the serial line are in the range from 0 ... 127.
CAUTION: GSM alphabet is not ASCII alphabet!
Several problems resulting from the use of the GSM alphabet:
1. "@" character with GSM alphabet value 0 is not printable by an ASCII terminal program (e.g.
©
®
Microsoft Hyperterminal ).
2. "@" character with GSM alphabet value of binary 0 will terminate any C string!
This is because the \0 is defined as C string end tag. Therefore, the GSM Null character may
cause problems on application level when using a ´C´-function as „strlen()“. This can be avoided if
it is represented by an escape sequence as shown in Table 4.
By the way, this may be the reason why even network providers often replace "@"with “@=*” in
their SIM application.
When sending e-mails via SMS the @ character may also be replaced with “*” as defined in GSM
03.40 (3GPP TS 23.040).
3. Other characters of the GSM alphabet are misinterpreted by an ASCII terminal program. For
example, GSM "ö" (as in "Börse") is assumed to be "|" in ASCII, thus resulting in "B|rse". This is
because both alphabets mean different characters with values hex. 7C or 00 and so on.
4. In addition, decimal 17 and 19 which are used as XON/XOFF control characters when software
flow control is activated, are interpreted as normal characters in the GSM alphabet.
When you write characters differently coded in ASCII and GSM (e.g. Ä, Ö, Ü), you need to enter
escape sequences. Such a character is translated into the corresponding GSM character value and,
when output later, the GSM character value can be presented. Any ASCII terminal then will show
wrong responses.
Table 4: Character definitions depending on alphabet (examples)
GSM 03.38
character
Ö
"
ò
@

GSM character
hex. value
5C
22
08
00

Corresponding
ASCII character
\
“
BSP
NULL

ASCII
Esc sequence
\5C
\22
\08
\00

Hex
Esc sequence
5C 35 43
5C 32 32
5C 30 38
5C 30 30

CAUTION: Often, the editors of terminal programs do not recognize escape sequences. In this case,
an escape sequence will be handled as normal characters. The most common workaround to this
problem is to write a script which includes a decimal code instead of an escape sequence. This way
you can write, for example, short messages which may contain differently coded characters.

TC3X_ATC_01_V04.00

Page 13 of 204

29.05.2002

AT Command Set

1.6

Flow control

Flow control is essential to prevent loss of data or avoid errors when, in a data or fax call, the sending
device is transferring data faster than the receiving side is ready to accept. When the receiving buffer
reaches its capacity, the receiving device should be capable to cause the sending device to pause
until it catches up.
There are basically two approaches to regulate data flow: software flow control and hardware flow
control. The High Watermark of the input / output buffer should be set to approximately 60% of the
total buffer size. The Low Watermark is recommended to be about 30%. The data flow should be
stopped when the capacity rises close to the High Watermark and resumed when it drops below the
Low Watermark. The time required to cause stop and go results in a hysteresis between the High and
Low Watermarks.
In Multiplex mode, it is recommended to use hardware flow control. For details please refer to [3].

1.6.1 Software flow control (XON/OFF flow control)
Software flow control sends different characters to stop (XOFF, decimal 19) and resume (XON,
decimal 17) data flow. The only advantage of software flow control is that three wires would be
sufficient on the serial interface.

1.6.2 Hardware flow control (RTS/CTS flow control)
Hardware flow control sets or resets the RTS/CTS wires. This approach is faster and more reliable,
and therefore, the better choice. When the High Watermark is reached, CTS is set inactive until the
transfer from the buffer has completed. When the Low Watermark is passed, CTS goes active once
again.
To achieve smooth data flow, ensure that the RTS/CTS lines are present on your application platform.
The application should include options to enable RTS/CTS handshake with the GSM engine. This
needs to be done with the AT command AT\Q3 - it is not sufficient to set RTS/CTS handshake in the
used Terminal program only.
The default setting of the GSM engine is AT\Q0 (no flow control) which must be altered to AT\Q3
(RTS/CTS hardware handshake on). The setting is stored volatile and must be restored each time
after the GSM engine was switched off. For further details refer to Chapter 2.3.
AT\Q has no read command. To verify the current setting of AT\Q, simply check the settings of the
active profile with AT&V.
Often, fax programs run an intialization procedure when started up. The intialization commonly
includes enabling RTS/CTS hardware handshake, eliminating the need to set AT\Q3 once again.
However, before setting up a CSD call, you are advised to check that RTS/CTS handshake is set.
Note:

After deactivating the RTS line, the ME may still send up to 32 bytes. This can be easily
handled if the buffer of the host application is sufficiently sized, and if a hysteresis is
implemented in its Rx buffer as mentioned in Chapter 1.6. A total buffer capacity of 256 bytes
has been proved to work well.

TC3X_ATC_01_V04.00

Page 14 of 204

29.05.2002

AT Command Set

2 Standard V.25ter AT Commands
These AT Commands are related to ITU-T (International Telecommunication Union,
Telecommunication sector) V.25ter document.
TC35,
TC37
and
TC35T
support
the
registers
S0-S29.
You
can
change
S0,S3,S4,S5,S6,S7,S8,S10,S18 by using the appropriate ATSn commands. All the other registers are
read-only and for internal usage only!

2.1

A/ Repeat previous command line

Execute command

Response

A/

Repeats previous command line. Line does not need to end with terminating
character.
Parameter

Reference

Note

V.25ter

· After beginning with the character “a“ or „A“, a second character “t“ ,”T“ or “/“
has to follow. In case of using a wrong second character, it is necessary to
start again with character “a“ or “A“.
· If autobauding is active (see +IPR, pg. 40) A/ (and a/) cannot be used.

2.2

+++ Switch from data mode to command mode

Execute command

Response

+++

This command is only available during data calls. The +++ character sequence
causes the TA to cancel the data flow over the AT interface and switch to
command mode. This allows you to enter AT commands while maintaining the
data connection to the remote device.
OK
To prevent the +++ escape sequence from being misinterpreted as data, it must
be preceded and followed by a pause of at least 1000 ms. The +++ characters
must be entered in quick succession, all within 1000 ms.

Reference

Note:

V.25ter

· To return from on-line command mode to on-line data mode: Enter ATO as
described in Chapter 2.17.

TC3X_ATC_01_V04.00

Page 15 of 204

29.05.2002

AT Command Set

2.3

AT\Qn Flowcontrol

Execute command

Response

AT\Q

OK
Parameter



Reference

0

AT\Q0

No flow control

1

AT\Q1

XON/XOFF software flow control

2

AT\Q2

Only CTS by DCE

3

AT\Q3

RTS/CTS hardware flow control
Required for the following procedures: incoming
or outgoing data calls, fax calls.
Often, the initialization routine of Fax programs
includes enabling RTS/CTS handshake,
eliminating the need to issue AT\Q3 once again.

Note

Line state refers to RS-232 levels.
The setting of AT\Q is stored volatile and must be restored each time after the
GSM engine was switched off. Also, there is no way to store AT\Q to the user
defined profile.
See also Chapter 1.6 for general information on flow control.

2.4

ATA Answer a call

Execute command

ATA

TA causes remote station to go off-hook (e.g. answer call).
Note1:
Any additional commands on the same command line are ignored.
Note2:

This command may be aborted generally by receiving a character during
execution. It can´t be aborted in some connection setup states, such as
handshaking.

Response

Response in case of data call, if successfully connected:
CONNECT TA switches to data mode.
Note:  output only if +ATX parameter setting with value > 0.
Response in case of voice call, if successfully connected:
OK
When TA returns to command mode after call release:
OK
Response if no connection:
NO CARRIER
Parameter
Reference

Note

V.25ter

See also AT+ATX and chapter 7.1.4 for 

TC3X_ATC_01_V04.00

Page 16 of 204

29.05.2002

AT Command Set

2.5

ATD Mobile originated call to dial a number

Execute command

ATD[]
[ TA switches to data state.
Note:

 output only if +ATX parameter setting with value > 0.

When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter



String of dialling digits and optionally V.25ter modifiers (dialling digits):
0-9, * , #, +, A, B, C
V.25ter modifiers: these are ignored: ,(comma), T, P, !, W, @

Emergency call:


= 112 worldwide number (no SIM needed)
 String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called
party)
i Deactivates CLIR (enables presentation of own phone number to
called party)
<;>
Only required to set up voice calls. TA remains in command mode.
Reference

Note

V.25ter/GSM
07.07

· Before setting up a data call, check that RTS/CTS handshake is enabled. See
Chapters 1.6 and 2.3.
· Parameter “l“ and “i“ only if no *#-code is within the dial string.
·  is not supported for data calls.
·  is default for last number that can be dialled by ATDL.
· See also +ATX and chapter 7.1.4 for .
· The *# codes can only be used with voice calls (i.e. use ´; ´) only.
· If ATD is used with a USSD command (e.g. ATD*100#;) an AT+CUSD=1 is
executed implicitly. (see AT+CUSD, pg. 116).

TC3X_ATC_01_V04.00

Page 17 of 204

29.05.2002

AT Command Set

2.6

ATD> Originate call to phone number  in memory 

This command allows you to dial a phone number from a specific phonebook. To initiate a call, enter
a two letter abbreviation for the phonebook , followed by the memory location  of the
desired entry. The location range of each phonebook can be queried by AT+CPBR (see Chapter
4.28).
Execute command

ATD>
[][;]

TA attempts to set up an outgoing call to the specified number.
Note:
This command may be aborted generally by receiving a character during
execution. Abortion is not possible during some states of connection
setup such as handshaking.
Response

If error is related to ME functionality:
+CME ERROR: 
If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
If successfully connected and non-voice call:
CONNECT TA switches to data state.
Note:  output only if +ATX parameter setting with value > 0.
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter

 phonebook:
"SM” SIM phonebook (storage depending on SIM card)

”FD” SIM fixdialling phonebook (pos. 1-7)
”LD” SIM last-dialling-phonebook (usually the last 10 numbers
dialed are stored on the SIM card, no matter whether or not the
calls were successfully set up)
”MC” ME missed (unanswered received) calls list (up to 10 numbers)
”RC” SIM received calls list
”ME” ME Phonebook (up to 50 numbers)
”ON” SIM (or ME) own numbers (MSISDNs) list
Note:  must be included in quotation marks (""), if parameter
 is used. If not, quotation marks are optional.


Integer type memory location in the range of locations available in
the selected memory, i.e. the index number returned by AT+CPBR.



I

TC3X_ATC_01_V04.00

Activates CLIR (disables presentation of own phone number to
called party)
Page 18 of 204

29.05.2002

AT Command Set

i
<;>

Deactivates CLIR (enables presentation of own phone number
to called party)

Only required to set up voice calls. TA remains in command mode.

Reference

Note

V.25ter/GSM
07.07

·
·
·
·
·

Example

To query the location number of the phonebook entry:
AT+CPBR=1,xx

There is no  for emergency call (“EN”).
Command is not supported for data call!
Parameter  only if no *# code is within the dial string.
The *# codes can only be used with voice calls (i.e.if “;” is appended).
See also ATX and chapter 7.1.4 for .

TA returns the entries available in the active phonebook.
To dial a number from the SIM phonebook, for example the number stored to
location 15:
ATD>SM15;
OK
To dial a phone number stored in the last dial memory on the SIM card:
ATD>LD9;
OK

TC3X_ATC_01_V04.00

Page 19 of 204

29.05.2002

AT Command Set

2.7

ATD> Originate call to phone number selected from active memory

This command can be used to dial a phone number selected from the active memory. The active
memory is the phonebook selected with AT+CPBS (see Chapter 4.29). To set up a call simply enter
the memory location of the desired entry. The memory location range of each phonebook can be
queried by AT+CPBR (see Chapter 4.28).
Execute command

ATD>[][;]

TA attempts to set up an outgoing call to the stored number.
Note: This command may be aborted generally by receiving a character
during execution. It can´t be aborted in some connection setup states,
such as handshaking.
Response

If error is related to ME functionality:
+CME ERROR: 
If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If a connection cannot be set up:
NO CARRIER
If successfully connected and non-voice call:
CONNECT TA switches to data state.
Note:  output only if +ATX parameter setting with value > 0.
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter



integer type memory location should be in the range of locations
available in the memory used, i.e. the index number returned by
AT+CPBR.

 I Activates CLIR (disables presentation of own phone number to
called party)
i Deactivates CLIR (enables presentation of own phone number
to called party)
<;>
Reference

Note

V.25ter/GSM 07.07

·
·
·
·

TC3X_ATC_01_V04.00

Only required to set up voice calls. TA remains in command mode.

Parameter  only if no *# code is within the dial string.
Command is not supported for data call!
The *# codes can only be used with voice calls (i.e.if “;” is appended).
See also +ATX and chapter 7.1.4 for .

Page 20 of 204

29.05.2002

AT Command Set

2.8

ATD> Originate call to phone number in memory with
corresponding field

This command searches the active phonebook for a given string  and dials the assigned phone
number. The active phonebook is the one set with AT+CPBS.
Execute command
TA attempts to set up an outgoing call to stored number
ATD>[mgsm][;] Note: This command may be aborted generally by receiving a character
during execution. It can´t be aborted in some connection setup states,
such as handshaking.
Response

If error is related to ME functionality:
+CME ERROR: 
If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If a connection cannot be set up:
NO CARRIER
If successfully connected and non-voice call:
CONNECT TA switches to data state.
Note:  output only if +ATX parameter setting with value > 0.
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter

string type value (“x”), which should equal an alphanumeric field in
at least one phonebook entry in the searched memories; used
character set should be the one selected with Select TE Character
Set +CSCS.  can contain escape sequences as described in
chapter „“, pg. 11.
 must be wrapped in quotation marks (""), if escape sequences
or parameter  are used or if the alphanumeric strings
contains a blank. If not, quotation marks are optional.
 I Activates CLIR (disables presentation of own phone number to
called party)
i Deactivates CLIR (enables presentation of own phone number to
called party)
<;>
Only required to set up voice calls. TA remains in command mode.


Reference

Note

V.25ter/GSM 07.07

Command is not supported for data calls! See also ATX and Chapter 7.1.4 for


TC3X_ATC_01_V04.00

Page 21 of 204

29.05.2002

AT Command Set

2.9

ATDI Mobile originated call to dialable ISDN number 

Execute command

ATDI[;]

TA attempts to set up an outgoing call to ISDN number.
Note:
This command may be aborted generally by receiving a character during
execution. This command cannot be aborted in some connection setup
states, such as handshaking.
Response

If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If a connection cannot be set up:
NO CARRIER
If successful connected and non-voice call:
CONNECT TA switches to data state.
Note:  output only if +ATX parameter setting with value > 0.
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter



[+]

phone number

string with maximum length of 20 characters
+

international dialling format



ISDN number
string of digits: +,0-9, A, B, C

<;>

voice call

Reference

V.25ter

TC3X_ATC_01_V04.00

Page 22 of 204

29.05.2002

AT Command Set

2.10 ATDL Redial last telephone number used
Execute command

ATDL[;]

This command redials the last voice and data call number used in the ATD
command.
· To redial the last data call number simply enter ATDL
· To redial the last voice call number type ATDL;
Note:

The command may be aborted generally by receiving a character during
execution. This command cannot be aborted in some connection setup
states, such as handshaking.

Response

If there is no last number or number is not valid:
+CME ERROR
If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If a connection cannot be set up:
NO CARRIER
If successfully connected and non-voice call:
CONNECT TA switches to data state.
Note:  output only if +ATX parameter setting with value > 0.
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter

<;>

voice call

Reference

Note

V.25ter

In case of voice calls “;” is necessary.

TC3X_ATC_01_V04.00

Page 23 of 204

29.05.2002

AT Command Set

2.11 ATE Enable command echo
Write command

ATE[]

This setting determines whether or not the TA echoes characters received from
TE during command state.
Response

OK
Parameter

 0 Echo mode off
1 Echo mode on
Reference

Note

V.25ter

In case of using the command without parameter,  is set to 0.

2.12 ATH Disconnect existing connection
Execute command

Disconnects any call in progress, such as voice calls, fax or CSD data calls.

ATH[n]
Response

OK
Note:

OK is issued after circuit 109 (DCD) is turned off (RS-232 level), if it was
previously on.
Parameter



0 terminate call

Reference

Note

V.25ter

Using ATH in Multiplex mode (AT+CMUX)
· ATH terminates every data call, even if it is issued via logical channels 2 or 3.
· This behaviour is in accordance with ITU-T V.25 ter; (07/97, see „6.3.6 Hook
control“: "ATH is terminating any call in progress.")

TC3X_ATC_01_V04.00

Page 24 of 204

29.05.2002

AT Command Set

2.13 ATI Display product identification information
Execute command

Response

ATI

ME issues product information text
SIEMENS
REVISION TC35 x.yy
xx.yy
OK
Explanation of „Revision“ parameter: Version xx and variant yy of software
release.

Reference

Note

V.25ter

2.14 ATI[value] Display additional identification information
Execute command

Response

ATI[value]

Delivers no specific information and simply returns OK.

Reference

Note

V.25ter

TC3X_ATC_01_V04.00

Page 25 of 204

29.05.2002

AT Command Set

2.15 ATL Set monitor speaker loudness
Execute command

Response

ATL[val]

OK

Reference

Note

V.25ter

· The two commands ATL and ATM are implemented only for V.25ter
compatibility reasons and have no effect.
· In multiplex mode the command is supported on logical channel 1 only.

2.16 ATM Set monitor speaker mode
Execute command

Response

ATM[val]

OK

Reference

Note

V.25ter

· The two commands ATL and ATM are implemented only for V.25ter
compatibility reasons and have no effect.
· In multiplex mode the command is supported on logical channel 1 only.

2.17 ATO Switch from command mode to data mode
Execute command

Response

ATO[n]

ATO is the corresponding command to the +++ escape sequence described in
Chapter 2.2: When you have established a data call and TA is in command mode,
ATO causes the TA to resume the data connection and return to data mode.
If connection is not successfully resumed
NO CARRIER
or
TA returns to data mode from command mode CONNECT 
Note:  output only if +ATX parameter setting with value > 0.
Parameter


Reference

0 switch from command mode to data mode

Note

V.25ter

TC3X_ATC_01_V04.00

Page 26 of 204

29.05.2002

AT Command Set

2.18 ATQ Set result code presentation mode
Write command

Response

ATQ[]

Specifies whether or not the TA transmits any result code to the TE. Information
text transmitted in response is not affected by this setting.
If =0:
OK
If =1:
(none)
Parameter



0 DCE transmits result code
1 Result codes are suppressed and not transmitted

Reference

Note

V.25ter

2.19 ATP Select pulse dialling
Execute command

Response

ATP

OK

Reference

Note

V.25ter

No effect for GSM

2.20 ATS0 Set number of rings before automatically answering the call
Read command

Response

ATS0?

 OK

Write command

Specifies whether or not the TA will accept an incoming data / fax call without
user intervention.  determines the number of rings to wait before the TA will
automatically answer.

ATS0=

Response

OK
Parameter



000

disables automatic answer mode

001-255 enables automatic answering after specified number of rings
Reference

Note

V.25ter

· Auto-answer mode is only applicable to data or fax calls.
· If  is set too high, the calling party may hang up before the call can be
automatically answered.
· The correlation between ATS7 and ATS0 is important.
Example: Call setup may fail if ATS0=20 and ATS7=30.

TC3X_ATC_01_V04.00

Page 27 of 204

29.05.2002

AT Command Set

2.21 ATS2 Escape code sequence
Read command

Response

ATS2?

S2 determines the decimal value of the ASCII character used in the escape code
sequence, which serves, during a data call, to change from data to command
mode. Compare Chapter 2.2.
The default value 043 is equivalent to an ASCII “+”. Please note that the value
cannot be changed, and therefore, test or write commands are not supported.

Reference

Note

V.25ter

2.22 ATS3 Write command line termination character
Read command

Response

ATS3?

 OK
This parameter setting determines the character recognized by TA to terminate
an incoming command line.

Write command

ATS3=

Response

OK
Parameter


Reference

000-013-127

command line termination character

Note

V.25ter

2.23 ATS4 Set response formatting character
Read command

Response

ATS4?

 OK

Write command

This parameter setting determines the character generated by the TA for result
code and information text.

ATS4=

Response

OK
Parameter


Reference

000-010-127

response formatting character.

Note

V.25ter

TC3X_ATC_01_V04.00

Page 28 of 204

29.05.2002

AT Command Set

2.24 ATS5 Write command line editing character
Read command

Response

ATS5?

 OK

Write command

This parameter setting determines the character recognized by TA as a request
to delete the immediately preceding character from the command line.

ATS5=

Response

OK
Parameter


Reference

000-008-127

command line editing character

Note

V.25ter

2.25 ATS6 Set pause before blind dialling
Read command

Response

ATS6?

 OK

Write command

No effect for GSM

ATS6=

Response

OK
Parameter


Reference

000-255 number of seconds to wait before blind dialling.

Note

V.25ter

TC3X_ATC_01_V04.00

Page 29 of 204

29.05.2002

AT Command Set

2.26 ATS7 Set number of seconds to wait for connection completion
Read command

Response

ATS7?

 OK

Write command

Specifies the number of seconds the TA will wait for the completion of the call
setup when answering or originating a data call. Also referred to as "no answer
timeout". To put it plainly, this is the time to wait for the carrier signal. If no carrier
signal is received within the specified time, the TA hangs up.

ATS7=

Response

OK
Parameter

0 

000 – 060 no. of seconds to wait for connection completion.

Reference

Note

V.25ter

· Values greater than 60 cause no error, but  will be restored to the
maximum value of 60.
· If called party has specified a high value for ATS0=, call setup may fail.
· The correlation between ATS7 and ATS0 is important.
Example: Call setup may fail if ATS7=30 and ATS0=20.
· ATS7 is only applicable to data calls.

2.27 ATS8 Set number of seconds to wait for comma dial modifier
Read command

Response

ATS8?

 OK

Write command

No effect for GSM

ATS8=

Response

OK
Reference

Note

V.25ter

TC3X_ATC_01_V04.00

Page 30 of 204

29.05.2002

AT Command Set

2.28 ATS10 Set disconnect delay after indicating the absence of data carrier
Read command

Response

ATS10?

 OK

Write command

This parameter setting determines the amount of time, that the TA remains
connected in absence of a data carrier. If the data carrier is detected before
disconnect, the TA remains connected.

ATS10=

Response
OK
Parameter


Reference

001-002-254

number of tenths of seconds of delay

Note

V.25ter

2.29 ATS18 Extended error report
Test command

Response

ATS18?

 OK

Execute command

TA returns an extended report of the reason for the last call release and location.

ATS18=


0 – 255, odd numbers set extended error report and even
numbers disable this feature.

Response

+Cause: :  OK
Parameter



Location ID as number code (see subclause 7.1.5).



Reason for last call release as number code (see subclause
7.1.5).

Reference

Note

Siemens

This command works for data calls only. For voice calls please use AT+CEER.

2.30 ATT Select tone dialling
Execute command

Response

ATT

OK

Reference

Note

V.25ter

No effect for GSM

TC3X_ATC_01_V04.00

Page 31 of 204

29.05.2002

AT Command Set

2.31 ATV Set result code format mode
Write command

Response

ATV[]

This parameter setting determines the contents of the header and trailer
transmitted with result codes and information responses.
When  =0
0
When  =1
OK
Parameter


0 Information response: 
Short result code format: 
1 Information response: 
Long result code format: 
Reference

Note

V.25ter

In case of using the command without parameter  will be set to 0.
Information responses described in chapter 7 (verbose code and numeric code).

2.32 ATX Set CONNECT result code format and call monitoring
Write command

Response

ATX[]

This parameter setting determines whether or not the TA detects the presence of
dial tone and busy signal and whether or not TA transmits particular result codes.
OK
Parameter


0

CONNECT result code only returned, dial tone and busy
detection are both disabled

1

CONNECT result code only returned, dial tone and busy
detection are both disabled

2

CONNECT result code returned, dial tone detection is
enabled, busy detection is disabled

3

CONNECT result code returned, dial tone detection is
disabled, busy detection is enabled

4

CONNECT result code returned, dial tone and busy
detection are both enabled

Reference

Note

V.25ter

Related  see chapter 7.1.4.

TC3X_ATC_01_V04.00

Page 32 of 204

29.05.2002

AT Command Set

2.33 ATZ Set all current parameters to user defined profile
Execute command

Response

ATZ[]

TA sets all current parameters to the user profile stored with AT&W (see Chapter
2.39 on page 37). If a connection is in progress, it will be terminated. The user
defined profile is stored to the non-volatile memory.
Note: If invalid, the user profile will be reset to the factory default profile. Any
additional commands on the same command line will be ignored. A delay of
300 ms is required before next command is sent, otherwise “OK” response may
be corrupted.
OK
Parameter

 0 Reset to user profile
Reference

Note

V.25ter

The GSM engines referred to in this manual can be assigned two profiles: the
factory profile (restored with AT&F) and the user profile (stored with AT&W). See
Chapter 2.36 for details on AT&F.

2.34 AT&C Set circuit Data Carrier Detect (DCD) function mode
Write command

Response

AT&C[]

This parameter determines how the state of circuit 109(DCD) relates to the
detection of received line signal from the distant end.
OK
Parameter



0

DCD line is always ON.

1

DCD line is ON in the presence of data carrier only.

Reference

Note

V.25ter

Line state refers to RS-232 levels.

TC3X_ATC_01_V04.00

Page 33 of 204

29.05.2002

AT Command Set

2.35 AT&D Set circuit Data Terminal Ready (DTR) function mode
Write command

Response

AT&D[]

This command is only intended for data calls. The  parameter determines
how the TA responds when circuit 108/2 (DTR) is changed from ON to OFF
during data mode.
OK
Parameter



0

TA ignores status on DTR.

1

ON->OFF on DTR: Change to command mode while retaining
the connected call.

2

ON->OFF on DTR: Disconnect data call, change to command
mode. During state DTR = OFF is auto-answer off.

Reference

Note

V.25ter

Line state refers to RS-232 levels.

2.36 AT&F Set all current parameters to manufacturer defaults
Execute command

Response

AT&F[value]

TA sets all current parameters to the manufacturer defined profile.
OK
Parameter



0

set all TA parameters to manufacturer default

Reference

Note

V.25ter

· List of parameters reset to manufacturer default (sorted by the associated AT
commands):
E, Q, V, X, +CBST, +CRLP, +CRC, +CR, +CNMI, +CMEE, +CSMS, ^SCKS,
^SACM, +CREG, +CLIP, the S Parameters, &D, &C, &S
· In addition to the default profile, you can store an individual one with AT&W. To
alternate between the two profiles enter either ATZ (loads user profile) or AT&F
(restores factory profile). Refer to Chapter 2.39 for AT&W and Chapter 2.33 for
ATZ.

TC3X_ATC_01_V04.00

Page 34 of 204

29.05.2002

AT Command Set

2.37 AT&S Set circuit Data Set Ready (DSR) function mode
Write command

Response

AT&S

This parameter determines how the TA sets circuit 107 (DSR) depending on the
communication state of the TA interfacing TE.
OK
Parameter



0

DSR always on.

1

TA in command mode: DSR is OFF.
TA in data mode: DSR is ON.

Reference

Note

V.25ter

Line state refers to RS-232 levels.

TC3X_ATC_01_V04.00

Page 35 of 204

29.05.2002

AT Command Set

2.38 AT&V Display current configuration
Execute command

Response

AT&V[]

TA returns the current parameter setting. The configuration varies depending on
whether or not PIN authentication has been done, or Multiplex mode has been
activated.
Parameter

Configuration
without Multiplex
mode or
configuration on
channel 1 if
Multiplex mode
is enabled

Logical channels
2 and 3
(Multiplex mode
enabled)


0 profile number
PIN entered (see AT+CPIN, pg. 95)
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+CRC: 0
+CMGF: 0
+CNMI: 0,0,0,0,1
+ILRR: 0
+IPR: 0
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0,1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"
OK
+CRC: 0
+CMGF: 0
+CNMI: 0,0,0,0,1
+ILRR: 0
+IPR: 19200
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0, 1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"

PIN not entered
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+ILRR: 0
+IPR: 0
+CMEE: 0
^SCKS: 0,1
OK

+ILRR: 0
+IPR: 19200
+CMEE: 0
^SCKS: 0,1
OK

OK
Reference

Note:

TC3X_ATC_01_V04.00

Parameter values and order are subject to change.

Page 36 of 204

29.05.2002

AT Command Set

2.39 AT&W Store current configuration to user defined profile
Execute command

TA stores the current settings to a user defined profile in the non-volatile memory.

AT&W[]
Response

OK or if error is related to ME functionality: ERROR / +CME ERROR: 
Parameter



0 number of profile

Reference

Note

V.25ter

The user defined profile will be loaded automatically after PowerUp. Use ATZ to
restore user profile and AT&F to restore factory settings. Until the first use of
AT&W, ATZ works as AT&F. See Chapter 2.33 for details on ATZ and Chapter
2.36 for AT&F.
List of settings stored to user defined profile:
· ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
User defined profiles in multiplex mode:
· On each multiplexer channel you can save an individual profile.
· List of settings stored to profile on multiplexer channel 1:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
· List of settings stored to profile on multiplexer channels 2 and 3:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS. (Parameters for data call are not relevant on channels 2 and 3.)

TC3X_ATC_01_V04.00

Page 37 of 204

29.05.2002

AT Command Set

2.40 AT+GCAP Request complete TA capabilities list
Test command

Response

AT+GCAP=?

OK
Parameter

Execute command

Response

AT+GCAP

TA reports a list of additional capabilities.
+GCAP: 
OK
Parameter

 e.g.: +CGSM,+FCLASS
Reference

Note

V.25ter

+CGSM: The response text shows which GSM commands of the ETSI standard
are supported.

2.41 AT+GMI Request manufacturer identification
Test command

Response

AT+GMI=?

OK

Execute command

Response

AT+GMI

TA reports information to identify the manufacturer.
SIEMENS
OK

Reference

Note

V.25ter

See also ”AT+CGMI Request manufacturer identification”.

2.42 AT+GMM Request TA model identification
Test command

Response

AT+GMM=?

OK

Execute command

TA reports one or more lines of information text which permit the user to identify
the specific model of device.
TC35
OK

AT+GMM

Reference

Note

V.25ter

See also ”AT+CGMM Request model identification”.

TC3X_ATC_01_V04.00

Page 38 of 204

29.05.2002

AT Command Set

2.43 AT+GMR Request TA revision identification of software status
Test command

Response

AT+GMR=?

OK

Execute command

Response

AT+GMR

TA returns product software version identification text.
REVISION x.yy
OK
x.yy

Version x and variant yy of software release.

Reference

Note

V.25ter

See also AT+CGMR Request revision identification of software status

2.44 AT+GSN Request TA serial number identification(IMEI)
Test command

Response

AT+GSN=?

OK

Execute command

Response

AT+GSN

TA reports one or more lines of information text which permit the user to identify
the individual device.

OK
Parameter



IMEI of the telephone(International Mobile station Equipment Identity)

Reference

Note

V.25ter

The serial number (IMEI) varies for every individual ME device.

TC3X_ATC_01_V04.00

Page 39 of 204

29.05.2002

AT Command Set

2.45 AT+ILRR Set TE-TA local rate reporting
Test command

Response

AT+ILRR=?

+ILRR: (list of supported s) OK
Parameter

See write command
Read command

Response

AT+ILRR?

+ILRR:  OK
Parameter

See write command
Write command

AT+ILRR=


The write command specifies whether or not an intermediate result code shall
indicate the currently used local rate when an incoming or outgoing data call is
established. The message is transmitted from the DCE (= TA) to the DTE (=TE)
before the final result code of the connection setup (e.g. CONNECT) appears.
Response

OK
Parameter

 0 Disables reporting of local port rate
1 Enables reporting of local port rate
Intermediate result code

+ILLR:
Parameter



port rate setting in bit per second
0 (Autobauding, see Chapter 2.46.1)
300
600
1200
2400
4800
9600
14400
19200
28800
38400
57600
115200

Reference

Note

V.25ter
Example

ATD030112233445
+ILRR: 57600
CONNECT 9600/RLP

TC3X_ATC_01_V04.00

Page 40 of 204

29.05.2002

AT Command Set

2.46 AT+IPR Set fixed local rate
Test command

Response

AT+IPR=?

+IPR: (list of supported auto-detectable s), (list of supported fixed-only
s) OK
Parameter

See write command
Read command

Response

AT+IPR?

+IPR:  OK
Parameter

See write command
Write command

AT+IPR=

This command specifies the DTE-DCE bitrate. When you set a fix rate, make sure
that both DTE (TE) and DCE (= TA) are configured to the same rate. When you
select autobauding the DCE will automatically recognize the bitrate currently used
by the DTE.
A selected bitrate takes effect following the issue of any result code associated
with this command (e.g. OK).
The setting is stored in the non-volatile memory and will be used whenever the
engine is powered up again. However, in case of autobaud mode (+IPR=0) the
detected DCE bitrate will not be saved and, therefore, needs to be be resynchronized after restarting the GSM engine (see Chapter 2.46.1).

Response

OK or if error is related to ME functionality: ERROR / +CME ERROR: 
Parameter

 bit rate per second
0 (Autobauding, see Chapter 2.46.1)
300
600
1200
2400
4800
9600
14400
19200
28800
38400
57600
115200
Reference

Note

V.25ter

Your current setting of AT+IPR will be preserved
· when you download new firmware (i.e. a firmware update does not restore the
factory setting);
· in the event of power failure.
Generally, AT+IPR=x should be used as a standalone command. If nevertheless
combinations with other commands on the same line cannot be avoided, there are
several constraints to be considered:
· Avoid combinations with the AT commands listed in Chapter 1.4.2.

TC3X_ATC_01_V04.00

Page 41 of 204

29.05.2002

AT Command Set

· Take into account that a delay of 100 ms is required between a response to the
last command (e.g. OK) and the next command on the same line.
· When you enter AT+IPR=0, autobauding will be activated after the response to
the last command is received.
· When local echo is active (ATE1) and you enter AT+IPR=x with other
commands you may encounter the following problem: If switching to the new
bit rate takes effect while a response is being transmitted, the last bytes may
be sent at the new bit rate and thus, not properly transmitted. The following
commands will be correctly sent at the new bit rate.

2.46.1 Autobauding
Autobauding allows the GSM engine to automatically detect the bitrate configured in the host
application. The serial interface of the GSM engine supports autobauding for the following bitrates:
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200. Factory setting is autobauding enabled. This
gives you the flexibility to put the GSM engine into operation no matter what bitrate your host
application is configured to.
To take advantage of autobaud mode specific attention must be paid to the following requirements:
Synchronization between DTE and DCE
Ensure that DTE and DCE are correctly synchronized and the bitrate used by the DTE is detected by
the DCE (= ME). To allow the bitrate to be synchronized simply issue an "AT" or "at" string. This is
necessary
· after you have activated autobauding
· when you start up the GSM engine while autobauding is enabled. It is recommended to wait 3 to 5
seconds before sending the first AT character. Otherwise undefined characters might be returned.
If you want to use autobauding and autoanswer at the same time, you can easily enable the
synchronization, when you activate autobauding first and then configure the autoanswer mode
(ATS0=0).
Restrictions on autobauding operation
· The serial interface has to be operated at 8 data bits, no parity and 1 stop bit (factory setting).
· The A/ command (and a/) cannot be used.
· Only the strings „AT“ or „at“ can be detected (neither „aT“ nor „At“).
· The Unsolicited Result Codes "^SYSSTART", "^SYSSTART ALARM MODE" and "^SYSSTART
CHARGE-ONLY MODE" are not indicated when you start up the ME while autobauding is enabled.
This is due to the fact that the new bitrate is not detected unless DTE and DCE are correctly
synchronized as described above.
· Any other Unsolicited Result Codes that may be issued before the ME detects the new bitrate (by
receiving the first AT command string) will be sent at the previous bitrate.
· It is not recommended to switch to autobauding from a bitrate that cannot be detected by the
autobaud mechnism (e.g. 300 baud). Responses to +IPR=0 and any commands on the same line
might be corrupted.
· When entering several AT commands on the same line, consider the requirements described in the
Notes of Chapter 2.46.
· See also AT+ILRR Set TE-TA local rate reporting , pg. 39
Autobauding and multiplex mode
If autobauding is active you cannot switch to multiplex mode (see +CMUX, pg. 86). Vice versa, when
you run the multiplex mode, the write command AT+IPR= cannot be used.

TC3X_ATC_01_V04.00

Page 42 of 204

29.05.2002

AT Command Set

3 AT Commands for FAX
The following commands can be used for FAX transmission.
If the ME is acting as a Fax-Modem to a PC-based application (e.g. „WinFax“) it is necessary to select
the proper Service Class (Fax Class) provided by the ME. The ME reports its Service Class
capabilities, both the current setting and the range of services available. This is provided by the
AT+FCLASS command (see pg. 45).
Note: When sending a FAX with a standard FAX application for Personal Computers it is
recommended to use Autobauding (AT+IPR=0).

ME

C
C

Currently defined Service Class values (see TIA/EIA-592-A)
+FCLASS parameter Service Class
Reference, Standard
e.g. TIA/EIA-602 or ITU V.25ter
0
data modem
1
1.0
2

C

2.0
2.1
8
Reserved

Service Class 1

EIA/TIA-578-A

Service Class 1
manufacture specific

ITU-T T.31
this document and EIA PN-2388 (draft)

Service Class 2
Service Class 2
Voice DCE

TIA/EIA-592
TIA/EIA-592-A or ITU-T T.32
TIA IS-101

Note: Be aware that there is a difference between Service Classes 2 and 2.0! Only the first is
applicable to the ME.

3.1

AT+FBADLIN Bad Line Threshold

Read command

AT+FBADLIN?

This command defines the “Copy-Quality-OK”-threshold. If 
consecutive lines have pixel count errors in normal resolution (98 dpi) mode,
then the copy quality is unacceptable. If  * 2 consecutive lines have
pixel count errors in fine resolution (196 dpi) mode, then the copy quality is
unacceptable. “Copy Quality Not OK” occurs if either the error percentage is too
high or too many consecutive lines contain errors. A value of 0 implies that error
checking is not present or disabled.
Response

 OK
Parameter

See write command
Write command

Response

AT+FBADLIN=


OK
If error is related to ME functionality:
ERROR
Parameter



0 – 10 – 255 bad lines

Reference

Note

EIA PN-2388

Used for Fax class 2 only

TC3X_ATC_01_V04.00

Page 43 of 204

29.05.2002

AT Command Set

3.2

AT+FBADMUL Error Threshold Multiplier

Read command

AT+FBADMUL?

This command defines the “Copy-Quality-OK” multiplier. The number of lines
received with a bad pixel count is multiplied by this number. If the result
exceeds the total number of lines on the page the error rate is considered too
high. A threshold multiplier value of 20 corresponds to a 5% error rate. A value
of 0 implies that error checking is not present or disabled.
Response

 OK
Parameter

See write command
Write command

Response

AT+FBADMUL=


OK
If error is related to ME functionality:
ERROR
Parameter



0 – 20 – 255

Reference

Note

EIA PN-2388

Used for Faxclass 2 only

3.3

AT+FBOR Query data bit order

Test command

AT+FBOR=?

Query the bit order for receive-mode. The mode is set by the ME dependent on
the selected Service Class, see “AT+FCLASS Fax: Select, read or test service
class”, pg. 45.
Response

(list of supported bit order modes s)
OK
Parameter

See write command
Read command

Response

AT+FBOR?

 OK
Parameter

See write command
Write command

Response

AT+FBOR=

OK
Parameter



0

direct bit order for both Phase C and for Phase B/D data.

1

Reversed bit order for Phase C data, direct Bit Order for
Phase B/D data.

Reference

Note

EIA PN-2388

Used for Fax class 2 only

TC3X_ATC_01_V04.00

Page 44 of 204

29.05.2002

AT Command Set

3.4

AT+FCIG Query or set the Local polling id

Test command

Response

AT+FCIG =?

(max. length of Local Polling ID string) (range of supported ASCII character
values) OK
Parameter

See write command
Read command

Response

AT+FCIG?

 OK
Parameter

See write command
Write command

Response

AT+FCIG =

OK
Parameter



Local Polling ID string, max. length and possible content as reported
by test command. Default value is empty string (“”).

Reference

Note

EIA PN-2388

See also “AT+FLID Query or set the Local Id setting capabilities”, pg. 51.
Used for Faxclass 2 only

3.5

AT+FCLASS Fax: Select, read or test service class

Test command

See introduction to fax commands, pg. 43.

AT+FCLASS=?

Response

(list of supported s)
OK
Parameter

See write command
Read command

Response

AT+FCLASS?

 OK
Parameter

Write command

AT+FCLASS=


See write command
The ME is set to a particular mode of operation (data, fax). This causes the MA
to process information in a manner suitable for that type of information.
Response

OK
Parameter



0

data (e.g. EIA/TIA-602 or ITU V.25ter)

1

Fax class 1 (EIA/TIA-578-A, Service Class 1)

2

Fax class 2 (EIA/TIA SP-2388, an early draft version of
EIA/TIA-592-A – Service class 2.1)

Reference

Note

EIA/TIA-592-A

Using Error Correcting Mode (ECM) when sending FAXes over GSM should be
avoided.

TC3X_ATC_01_V04.00

Page 45 of 204

29.05.2002

AT Command Set

3.6

AT+FCQ Copy Quality Checking

Test command

This command controls Copy Quality checking when receiving a fax.

AT+FCQ =?

Response

(list of supported copy quality checking s)
OK
Parameter

See write command
Read command

Response

AT+FCQ?

 OK
Parameter

See write command
Write command

Response

AT+FCQ =

OK
Parameter



0

No copy quality checking. The ME will generate Copy
Quality OK (MCF) responses to complete pages.

1

ME can check 1-D phase data. The connected application
must check copy quality for 2-D phase C data

Reference

Note

EIA PN-2388

Used for for Faxclass 2 only.

3.7

AT+FCR Capability to receive

Write command

Response

AT+FCR=

OK
Parameter



0

ME will not receive message data. This can be used when
the application has insufficient storage. The ME can send
and can be polled for a file.

1

ME can receive message data.

Reference

Note

EIA PN-2388

Used for Faxclass 2 only

TC3X_ATC_01_V04.00

Page 46 of 204

29.05.2002

AT Command Set

3.8

AT+FDCC Query or set capabilities

Test command

AT+FDCC =?

This command allows the connected application to sense and constrain the
capabilities of the facsimile DCE (=ME), from the choices defined in CCITT
T.30 Table 2.
Response

(list of s), (list of 
s), (list of s), (list of s), (list of s), (list of s), (list of s), (list of s) OK Parameter VR: Vertical Resolution, BR: Bit Rate, WD: Page Width, LN: Page Length, DF: Data Compression Format, EC: Error Correction Mode, BF: Binary File Transfer Mode, ST: Scan Time/Line. Note: For further information see AT+FDIS, pg. 49 Read command Response AT+FDCC? OK Parameter See write command Write command Response AT+FDCC=,
,,, ,,, OK Reference Note EIA PN-2388 Used for Faxclass 2 only TC3X_ATC_01_V04.00 Parameter VR: Vertical Resolution, BR: Bit Rate, WD: Page Width, LN: Page Length, DF: Data Compression Format, EC: Error Correction Mode, BF: Binary File Transfer Mode, ST: Scan Time/Line. Note: For further information see AT+FDIS, pg. 49 Page 47 of 204 29.05.2002 AT Command Set 3.9 AT+FDFFC Data Compression Format Conversion Test command AT+FDFFC=? This parameter determines the ME response to a mismatch between the data format negotiated for the facsimile session, reported by the +FDCS:DF subparameter, and the Phase C data desired by the controlling application, indicated by the optional +FDT:DF subparameter, or the +FDIS=DF subparameter for the +FDR operation. Response (list of supported s) OK Parameter See write command Read command Response AT+FDFFC? OK Parameter See write command Write command Response AT+FDFFC = OK Parameter 0 Mismatch checking is always disabled. The controlling application has to check the +FDCS: DF subparameter and transfer matching data. Reference Note EIA PN-2388 Used for Fax Class 2 only TC3X_ATC_01_V04.00 Page 48 of 204 29.05.2002 AT Command Set 3.10 AT+FDIS Query or set session parameters Test command AT+FDIS =? This command allows the controlling application to sense and constrain the capabilities used for the current session. It uses +FDIS to generate DIS or DTC messages directly, and uses +FDIS and received DIS messages to generate DCS messages. Response (list of s), (list of
s), (list of s), (list of s), (list of s), (list of s), (list of s), (list of s) Parameter See write command Read command Response AT+FDIS? OK Parameter See write command Write command Response AT+FDIS = ,
,, ,,, , OK Reference Note EIA PN-2388 Used for Faxclass 2 only TC3X_ATC_01_V04.00 Parameter Vertical Resolution VR 0 normal, 98 lpi 1 fine, 196 lpi Bit Rate BR 0 2400 bit/s, V.27ter 1 4800 bit/s, V.27ter 2 7200 bit/s, V.29 3 9600 bit/s, V.29 Page Width WD 0 *) 1728 pixels in 215mm 1 2048 pixels in 255 mm 2 2432 pixels in 303 mm 3 1216 pixels in 151 mm 4 864 pixels in 107 mm Page Length LN 0 A4, 297mm 1 B4, 364mm 2 unlimited length Data Compression Format DF 0 *) 1-D modified Huffman 1 2-D modified read 2 2-D uncompressed mode Error correction EC 0 *) disable ECM (Annex A/T.30) 1 enable ECM, 64 bytes/frame 2 enable ECM, 256 bytes/frame Binary File mode BF 0 *) disable BFT Transfer Mode 1 enable BFT Scan Time/Line ST 0 *) 0 ms (at VR= normal) 1 5 ms 2 10 ms 3 10 ms 4 20 ms 5 20 ms 6 40 ms 7 40 ms *) Note: Only the default value needs to be implemented. Use test command to check which parameter values are really possible! Page 49 of 204 29.05.2002 AT Command Set 3.11 AT+FDR Begin or continue phase C data reception Execute command The +FDR command initiates transition to Phase C data reception. AT+FDR Response CONNECT or OK If error is related to ME functionality: ERROR Reference Note EIA PN-2388 Used for Faxclass 2 only 3.12 AT+FDT Data Transmission Execute command AT+FDT This command requests the ME to transmit a Phase C page. When the ME is ready to accept Phase C data, it issues the negotiation responses and the CONNECT result code to the application. In Phase B, the +FDT command releases the ME to proceed with negotiation, and releases the DCS message to the remote station. In Phase C, the +FDT command resumes transmission after the end of a data stream transmited before. Response CONNECT Write command Response AT+FDT =
CONNECT Parameter
DF,VR,BR,WD,LN comma separated parameter list Data Compression Format DF 0 1 2 1-D modified Huffman 2-D modified read 2-D uncompressed mode Vertical Resolution VR Bit Rate BR 0 1 0 1 2 3 normal, 98 lpi fine, 196 lpi 2400 bit/s, V.27ter 4800 bit/s, V.27ter 7200 bit/s, V.29 9600 bit/s, V.29 Page Width WD Page Length LN 0 1 2 3 4 0 1 2 1728 pixels in 215mm 2048 pixels in 255 mm 2432 pixels in 303 mm 1216 pixels in 151 mm 864 pixels in 107 mm A4, 297mm B4, 364mm unlimited length Reference Note EIA PN-2388 Used for Faxclass 2 only TC3X_ATC_01_V04.00 Page 50 of 204 29.05.2002 AT Command Set 3.13 AT+FET End a page or document Write command AT+FET= This command indicates that the current page or partial page is complete. An ERROR response code results if this command is issued while the mode is onhook. Response OK Parameter Post Page Message Codes 1 another document next 2 no more pages or documents 4 another page, procedure interrupt 5 another document, procedure interrupt Reference Note EIA PN-2388 Used for Faxclass 2 only 3.14 AT+FK Kill operation, orderly FAX abort Execute command This command causes the TA to terminate the session in an orderly manner. AT+FK Response OK Reference Note Used for Faxclass 2 only 3.15 AT+FLID Query or set the Local Id setting capabilities Test command Response AT+FLID =? (max. character length of Local ID string) (range of supported ASCII character values) OK Parameter See write command Read command Response AT+FLID? < lid > OK Parameter See write command Write command Response AT+FLID = OK Parameter Local ID string, max. length and possible content as reported by test command. Default value is empty string (“”). Reference Note EIA PN-2388 See also “AT+FCIG Query or set the Local polling id ”, pg. 44. Used for Faxclass 2 only TC3X_ATC_01_V04.00 Page 51 of 204 29.05.2002 AT Command Set 3.16 AT+FMDL Identify Product Model Read command Send the model identification to the TA AT+FMDL? Response Gipsy Soft Protocolstack OK Reference Note Siemens Used for Faxclass 2 only 3.17 AT+FMFR Request Manufacturer Identification Read command Send the manufacturer identification to the TA AT+FMFR? Response SIEMENS OK Reference Note Siemens Used for Fax class 2 only 3.18 AT+FOPT Set bit order independently Write command AT+FOPT= Model specific command to set bit order independently of the understanding which is "mirrored" and which is direct. Response OK Parameter 0 non-standard 1 standard Reference Note Siemens Used for Fax class 2 only TC3X_ATC_01_V04.00 Page 52 of 204 29.05.2002 AT Command Set 3.19 AT+FPHCTO DTE Phase C Response Timeout Read command AT+FPHCTO? The time-out value determines how long the DCE will wait for a command after reaching the end of data when transmitting in Phase C. When time-out is reached, the DCE assumes that there are no more pages or documents to send. Response OK Parameter See write command Write command Parameter AT+FPHCTO= 0 – 30 – 255 time-out value in 100ms units. Response OK If error is related to ME functionality: ERROR Reference Note EIA PN-2388 Used for Fax class 2 only 3.20 AT+FREV Identify Product Revision Test command Sends the revision identification to the TA AT+FREV? Response V2.550 OK Reference Note Siemens Used for Fax class 2 only 3.21 AT+FRH Receive Data Using HDLC Framing Execute command This command causes the TA to receive frames using the HDLC protocol and the AT+FRH= modulation defined below. An ERROR response code results if this command is issued while the modem is on-hook. Response CONNECT If error is related to ME functionality: ERROR Parameter modulation mode 3 V21 Ch2 24 V.27ter 2400 bps 48 V.27ter 4800 bps 72 V.29 7200 bps 96 V.29 9600 bps Reference Note TIA/EIA-578 Used for Fax class 1 only TC3X_ATC_01_V04.00 300 bps Page 53 of 204 29.05.2002 AT Command Set 3.22 AT+FRM Receive Data Test command Response AT+FRM=? (List of supported modulation modes s) OK Parameter Write command AT+FRM= See write command This command causes the TA to enter the receiver-mode using the modulation defined below. An ERROR response code results if this command is issued while the modem is on-hook. Response CONNECT If error is related to ME functionality: ERROR Parameter 96 V.29 9600 bps 72 V.29 7200 bps 48 V.27ter 4800 bps 24 V.27ter 2400 bps Reference Note TIA/EIA-578 Used for Faxclass 1 only 3.23 AT+FRS Receive Silence Write command AT+FRS=

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Modify Date                     : 2002:05:29 17:57:38+02:00
Create Date                     : 2002:05:29 15:55:08Z
Page Count                      : 204
Creation Date                   : 2002:05:29 15:55:08Z
Mod Date                        : 2002:05:29 17:57:38+02:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : 
Metadata Date                   : 2002:05:29 17:57:38+02:00
Creator                         : 
Title                           : AT Command Set
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu