Proposed Scope Of Accreditation TRA Cal 2019
User Manual: TRA-Cal-Scope-2019
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
Certificate # L2151 Scope of Accreditation For Tra-Cal, LLC 7901 Beechcraft Avenue, Suite M & N Gaithersburg, MD 20879 Todd Chaikin 301-527-9200 In recognition of a successful assessment to ISO/IEC 17025:2005, ANSI/NCSL Z540-1:1994(R2002), and ANSI/NCSL Z540.3:2006(R2014) sub-clause 5.3 to the following Calibration and Measurement Capabilities, accreditation has been granted to Tra-Cal, LLC for the following: Accreditation granted through: May 31, 2019 Calibration Electrical – Calibration Parameter/Equipment Capacitance1 Range Expanded Uncertainty of Measurement (+/-) 1 nF 0.2 pF 0.1 µF 0.0000 29 µF 10 Hz to 10 kHz 190 pF to 1.0999 nF 10 Hz to 3 kHz 1.1 nF to 3.2999 nF 0.028 nF 0.031 nF 10 Hz to 1 kHz 3.3 nF to 10.9999 nF 0.044 nF 10 Hz to 1 kHz (11 to 32.99) nF 0.21 nF 10 Hz to 1 kHz (33 to 109.99) nF 0.44 nF 10 Hz to 1 kHz (110 to 329.99) nF 1.3 nF (10 to 600) Hz (0.33 to 1.09) µF 0.007 2 µF (10 to 300) Hz (1.1 to 3.29) µF 0.014 µF (10 to 150) Hz (3.3 to 10.99) µF 0.045 µF (10 to 120) Hz (11 to 32.99) µF 0.19 µF (10 to 80) Hz (33 to 109.99) µF 0.69 µF DC to 50 Hz (110 to 329.99) µF 2.1 µF DC to 20 Hz (0.33 to 1.09) mF 0.009 mF DC to 6 Hz (1.1 to 3.29) mF 0.021 mF DC to 2 Hz (3.3 to 10.99) mF 0.069 mF DC to 0.6 Hz (11 to 32.99) mF 0.32 mF DC to 0.2 Hz (33 to 99.99) mF 1.4 mF Capacitance – Source 1 kHz 1 kHz Form 28.8—Rev 11 – 3/1/14 Remarks GR 1404-A Capacitor GR 1409-T Capacitor Fluke 5520A Calibrator Page 1 of 12 Calibration Parameter/Equipment Certificate # L2151 Remarks Range Expanded Uncertainty of Measurement (+/-) Capacitance - Measure 1 kHz (200 pF to 20 µF) 0.045 µF Electrical – Current1 Calibration Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-) (0 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A 0.000 15 mA 0.001 5 mA 0.018 mA 0.24 mA (2.2 to 11) A 0.007 4 A (11 to 20) A 0.023A (20 to 100) A 2.7 A HP 6260B power supply (0 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 0.3 nA 0.000 97 µA 0.000 45µA 0.003 2 µA 0.005 mA 0.007 mA 0.011 mA 0.15 mA Agilent 3458A 8 ½ Digit Multimeter DC Current – Source GenRad 1689 Precision RLC Digibridge Remarks Fluke 5700A Calibrator Fluke 5520A Calibrator DC Current – Measure DC Current - Measure AC Current - Source Form 28.8—Rev 11 – 3/1/14 (1 to 10) A (0 to 25) A (25 to 50) A (50 to 100) A (100 to 750) A (750 to 1 000) A (0 to 220) µA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (0.22 to 2.2) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.025 A 0.29 % of reading 0.34 % of reading 0.34 % of reading 0.36 % of reading 0.31 % of reading 0.2 µA 0.11 µA 0.042 µA 0.18 µA 0.46 µA Fluke 45 Multimeter Current Shunt Monitored with DMM Fluke 5700A Calibrator 0.002 mA 0.001 1mA 0.000 42 mA 0.001 8 mA 0.004 6 mA Page 2 of 12 Calibration Parameter/Equipment AC Current - Source AC Current - Source AC Current - Measure Form 28.8—Rev 11 – 3/1/14 Range (2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (0.22 to 2.2) A 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (2.2 to 11) A 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (0 to 100) µA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (0.1 to 1.0) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 10) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 100) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz Expanded Uncertainty of Measurement (+/-) Certificate # L2151 Remarks 0.021 mA 0.011 mA 0.004 2 mA 0.018 mA 0.046 mA 0.2 mA 0.11 mA 0.047 mA 0.18 mA 0.46 mA Fluke 5700A Calibrator 0.001 9 A 0.002 2 A 0.025 A 0.007 9 A 0.012 A 0.042 A Fluke 5700A/5725 Calibrator 0.5 uA 0.22 uA 0.13 uA 0.004 6 mA 0.002 mA 0.001 mA 0.000 77mA 0.000 92 mA 0.005 1 mA 0.008 1 mA 0.049 mA 0.02 mA 0.011 mA 0.007 7 mA 0.011 mA 0.051 mA 0.081 mA Agilent 3458A 8 ½ Digit DMM 0.49 mA 0.2 mA 0.11 mA 0.077 mA 0.11 mA 0.51 mA 0.81 mA Page 3 of 12 Calibration Parameter/Equipment AC Current - Measure AC Current - Measure Electrical – Inductance Calibration Parameter/Equipment Range (0.1 to 1.0) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (1 to 10) A 45 Hz to 1 kHz Expanded Uncertainty of Measurement (+/-) 0.005 A 0.002 4 A 0.001 7 A 0.001 8 A 0.003 9 A 0.012 A 0.34 A Certificate # L2151 Remarks Agilent 3458A 8 ½ Digit DMM Fluke 45 DMM Range Expanded Uncertainty of Measurement (+/-) Remarks 100 µH 0.29 µH GR 1482-B 10 mH 0.012 mH GR 1482-H 1 kHz 100 mH 0.13 mH GR 1482-L (0.1 to 1) kHz 500 mH 0.76 mH GR 1482-N 100 Hz 1H 0.001 3 H GR 1482-P 1 kHz 1H 0.001 3 H GR 1482-P (0.1 to 1) kHz 10 H 0.015 H GR 1482-T 10 H 0.015 H GR 1482-T 100 µH to 10 H 0.23 % of reading 0.29 µH GenRad 1689 Range Expanded Uncertainty of Measurement (+/-) Remarks 1Ω 85 µΩ L&N 4020B resistor 10 Ω 0.99 mΩ L&N 4025B resistor 100 Ω 3.8 mΩ L&N 4030B resistor 1 kΩ 28 mΩ L&N 4035B resistor 10 kΩ 0.13 Ω Fluke 742A-10k resistor 100 kΩ 3.4 Ω L&N 4045B resistor 1 MΩ 38 Ω L&N 4050B resistor Inductance – Source 1 kHz 1 kHz (0.1 to 1) kHz Inductance - Measure 1 kHz Electrical – Resistance1 Calibration Parameter/Equipment Resistance Source Form 28.8—Rev 11 – 3/1/14 Page 4 of 12 Calibration Parameter/Equipment Resistance Source Resistance Source Resistance Measure Resistance Measure Form 28.8—Rev 11 – 3/1/14 Range 1 1.9 10 19 100 190 1 k 1.9 k 10 k 19 k 100 k 190 k 1 M 1.9 M 10 M 19 M 100 M Expanded Uncertainty of Measurement (+/-) Certificate # L2151 Remarks 0.000 13 0.000 013 0.000 094 0.000 15 0.000 25 0.000 41 0.002 0.003 3 0.018 0.039 0.22 0.55 4.1 62 kΩ 35 kΩ 53 kΩ 62 kΩ Fluke 5700A Calibrator (0 to 11) (11 to 33) (33 to 110) (110 to 330) (0.33 to 1.1) k (1.1 to 3.29) k (3.3 to 11) k (11 to 32.99) k (33 to 110) k (110 to 330) k 330 k to 1.1 M (1.1 to 3.3) M (3.3 to 11) M (11 to 33) M (33 to 110) M (110 to 330) M (330 to 1 100) M 0.001 2 0.001 7 0.001 7 0.002 9 0.006 1 0.034 0.083 0.34 0.84 3.2 6.9 50 210 3.5 k 9.7 k 140 kΩ 1.4 MΩ Fluke 5520A Calibrator (0 to 1) Ω 81 µΩ (1 to 10) Ω 0.39 mΩ (10 to 100) Ω 2.5 mΩ (0.1 to 1) kΩ 17 mΩ (1 to 10) kΩ 17 mΩ (10 to 100) kΩ 1.7 Ω (0.1 to 1) MΩ 27 Ω (1 to 10) MΩ 0.61 MΩ (10 to 100) MΩ 4.2 MΩ (0.1 to 1) GΩ 8.2 MΩ Agilent 3458A 8 ½ Digit Multimeter Agilent 3458A 8 ½ Digit Multimeter Page 5 of 12 Calibration Parameter/Equipment Certificate # L2151 Remarks Range Expanded Uncertainty of Measurement (+/-) (-200 to 800) °C 0.27 ºC (-200 to 630) °C 0.2 ºC Pt 385, 500 Ω (-200 to 630) °C 0.22 ºC Pt 385, 1 k Ω (-200 to 630) °C 0.46 ºC Pt 3916, 100 Ω (-200 to 630) °C 0.29 ºC Pt 3926, 100 Ω (-200 to 630) °C 0.14 ºC Cu 427, 10 Ω (-100 to 260) °C 0.35 ºC Range Expanded Uncertainty of Measurement (+/-) Remarks 10 MHz to 2.3 GHz (2.3 to 18.6) GHz (18.6 to 26.5) GHz (-20 to 18) dBm (-20 to 18) dBm (-20 to 18) dBm 1.1 dB 1.7 dB 2.3 dB HP 8340B/83554A Signal Generator (26.5 to 40) GHz (40 to 50) GHz (-25 to 3) dBm (-25 to 0) dBm 1.2 dB 2.2 dB HP 83650B Signal Generator 200 Hz to 10.0 MHz 10MHz to 80.0MHz (-86.98 to 13.01) dBm (-86.98 to 13.01) dBm 0.42 dB 0.13 dB HP 3335A Signal Generator RF Power Flatness Source 200 Hz to 10 MHz 10 MHz to 25 MHz 25 MHz to 80 MHz (-86.98 to 13.01) dBm (-86.98 to 13.01) dBm (-86.98 to 13.01) dBm 0.42 dBm 0.14 dBm 0.21 dBm HP 3335A Signal Generator 10 MHz to 2.3 GHz (2.3 to 18.6) GHz (18.6 to 26.5) GHz (-20 to 18) dBm (-20 to 18) dBm (-20 to 18) dBm 1.1 dB 1.7 dB 2.3 dB HP8340B Signal Generator (26.5 to 40) GHz (40 to 50) GHz (-25 to 3) dBm (-25 to 0) dBm 1.2 dB 2.2 dB HP 83650B Signal Generator RTD Resistance Simulation Pt 395, 100 Ω Pt 385, 200 Ω Electrical – RF Power Calibration Parameter/Equipment Fluke 5520A Calibrator RF Power - Source Form 28.8—Rev 11 – 3/1/14 Page 6 of 12 Calibration Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-) (-12 to 0) dB (-12 to -22) dB (-22 to -31) dB (-31 to -40) dB (-40 to -50) dB (-50 to -61) dB (-61 to -71) dB (-71 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB 0.18 dB 0.21 dB 0.23 dB 0.27 dB 0.29 dB 0.32 dB 0.34 dB 0.51 dB 0.60 dB 0.62 dB 0.65 dB 0.69 dB 150 kHz to 2.6 GHz 0.33 dB + 0.1 dB/dB (-25 to +20) dBm 100 kHz to 4.2 GHz 10 MHz to 18 GHz 50 MHz to 26.5 GHz 50 MHz to 50 GHz 0.29 dB 0.13 dB 0.23 dB 0.4 dB Distortion 20 Hz to 20 kHz (20 to 100) kHz 1.5 dB 3.1 dB Range Expanded Uncertainty of Measurement (+/-) (0 to 220) mV 6.6 µV (0.22 to 2.2) V 22 µV (2.2 to 11) V 0.1 mV (11 to 22) V 0.23 mV (22 to 220) V 2.4 mV (220 to 1 000) V 15 mV 1 µV to 100 mV 3.3 µV (0.1 to 1) V 14 µV (1 to 10) V 59 µV (10 to 100) V 0.8 mV (100 to 1 000) V 16 mV (1 to 10) kV 360 V (10 to 25) kV 400 V (25 to 40) kV 1.9 kV RF Relative Attenuation 2.5 MHz to 26.5 GHz RF Power - Measure (-127 to -30) dBm Electrical – Voltage1 Calibration Parameter/Equipment DC Voltage - Source DC Voltage – Measure Form 28.8—Rev 11 – 3/1/14 Certificate # L2151 Remarks HP 8902A Measuring Receiver w/11793A HP 8902A Measuring Receiver w/11722A Sensor HP 438A Power Meter w/ 8482A Sensor w/ 8481A Sensor w/ 8485A Sensor w/ 8487A Sensor HP 8903B Remarks Fluke 5700A/5725A Calibrator Agilent 3458A 8 ½ Digit Multimeter Fluke 80K-40 w/8 ½ Digit Multimeter Page 7 of 12 Calibration Parameter/Equipment Range 2.2 mV to 22 mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 22 mV to 220 mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz AC Voltage Source AC Voltage Source Form 28.8—Rev 11 – 3/1/14 Expanded Uncertainty of Measurement (+/-) 0.002 7 mV 0.001 8 mV 0.001 7 mV 0.003 1 mV 0.004 6 mV 0.007 6 mV 0.011 mV 0.015 mV 0.015 mV 0.006 3 mV 0.003 4 mV 0.011 mV 0.024 mV 0.034 mV 0.047 mV 0.08 mV 220 mV to 2.2 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.15 mV 0.061 mV 0.028 mV 0.092 mV 0.2 mV 0.28 mV 0.46 mV 0.92 mV 2.2 V to 22 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.001 5 V 0.000 46 V 0.000 22 V 0.000 36 V 0.000 72 V 0.001 2 V 0.003 1 V 0.006 1 V 22 V to 220 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz Certificate # L2151 Remarks 0.015 V 0.004 6 V 0.002 2 V 0.003 6 V 0.007 2 V 0.015 V 0.036 V 0.076 V Fluke 5700A/5725A Calibrator Fluke 5700A/5725A Calibrator Page 8 of 12 Calibration Parameter/Equipment AC Voltage Source Range 220 V to 750 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.5 to 1) MHz 750 V (30 to 50) kHz (50 to 100) kHz 1100 V 50 Hz to 1 kHz 1100 V 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz AC Voltage – Measurement AC Voltage – Measurement Form 28.8—Rev 11 – 3/1/14 Expanded Uncertainty of Measurement (+/-) 0.15 V 0.046 V 0.023 V 0.064 V 0.15 V 0.41 V 1.4 V 3.3 V Certificate # L2151 Remarks Fluke 5700A/5725A Calibrator 0.52 V 2V Fluke 5725A Calibrator 0.12 V Fluke 5700A Calibrator 0.11 V 0.21 V 0.76 V Fluke 5725A Calibrator 10 mV to 100 mV (1 to 40) Hz 40Hz to 1kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.1 to 10) V (1 to 40) Hz 40Hz to 1kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1MHz (1 to 2) MHz 0.000 085 V 0.000 085 V 0.000 17 V 0.000 36 V 0.001 2 V 0.005 8 V 0.012 V 0.018 V (10 to 100) V (1 to 40) Hz 40Hz to 1kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.024 V 0.024 V 0.024 V 0.041 V 0.14 V 0.46 V (100 to 1 000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.46 V 0.46 V 0.69 V 1.4 V 3.5 V 0.003 6 mV 0.002 5 mV 0.003 6 mV 0.012 mV 0.058 mV 0.46 mV Agilent 3458A 8 ½ Digit Multimeter Agilent 3458A 8 ½ Digit Multimeter Page 9 of 12 Calibration Parameter/Equipment AC Voltage – Measurement Range Expanded Uncertainty of Measurement (+/-) (2 to 20) mV 200 kHz to 1 MHz (1 to 10) MHz (10 to 20) MHz 1.7 mV 2.0 mV 2.5 mV (0.02 to 20) V 200kHz to 1MHz (1 to 10) MHz (10 to 20) MHz 0.25 V 0.29 V 0.36 V Thermocouple Millivolt Simulation Type C Type E (0 to 2 316) °C 0.98 ºC (-250 to 1 000) °C 0.44 ºC Type J (-210 to 1 200) °C 0.31 ºC Type K (-200 to 1 372) °C 0.47 ºC Type N (-200 to 1 300) °C 0.47 ºC Type R (0 to 1 767) °C 0.66 ºC Type S (0 to 1 767) °C 0.55 ºC Type T (-250 to 400) °C 0.73 ºC Type U (-200 to 600) °C 0.65 ºC Thermodynamic – Humidity Calibration Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-) Relative Humidity (23 ± 5) °C (10 to 80) % RH 2.4 % RH Thermodynamic – Thermodynamic Sources1 Calibration Range Parameter/Equipment Temperature Measurement (Ovens, Furnaces, Freezers, Chambers, Ice Baths – System Accuracy Test) (-45 to 200) ºC 2.2 ºC (200 to 500) ºC 2.5 ºC Time and Frequency – Frequency / Period Calibration Range Parameter/Equipment Frequency – Source2 Form 28.8—Rev 11 – 3/1/14 Expanded Uncertainty of Measurement (+/-) Certificate # L2151 Remarks Fluke 8920A True RMS Voltmeter Fluke 5520A Calibrator Remarks Veriteq SP-2000 Logger Remarks Fluke 51 with Type J TC probe Expanded Uncertainty of Measurement (+/-) Remarks 10 MHz 7.6 · 10-11 · f DC to 20 MHz 7.6 · 10-11 · f + 0.58 Hz HP 58503A GPS Receiver HP 3325B Generator 10 MHz to 26.5 GHz 7.6 · 10-11 · f + 1.2 Hz HP 8340B Generator Page 10 of 12 Calibration Parameter/Equipment Certificate # L2151 Remarks Range Expanded Uncertainty of Measurement (+/-) 1 Hz to 225 MHz 7.6 · 10-11 · f + 0.6 mHz HP 53131A Counter 10 Hz to 525 MHz 7.6 · 10-11 · f + 0.58 Hz 5351B 50 Ω Counter (0.5 to 26.5) GHz 7.6 · 10-11 · f + 0.58 Hz 5351B 50 Ω Counter CW (0.25 to 10) MHz 0.24 kHz HP 8902A Measuring Receiver CW (0.01 to 1.3) GHz 5.9 kHz Rate (20 Hz to 10 kHz) Depth (10 to 99) % CW (0.15 to 10) MHz 3.6 % of reading Rate (50 Hz to 10 kHz) Depth (10 to 99) % CW (0.15 to 10) MHz 2.4 % of reading Rate (20 Hz to 100 kHz) Depth (10 to 99) % CW (0.01 to 1.3) GHz 3.6 % of reading Rate (50 Hz to 50 kHz) Depth (10 to 99) % CW (0.01 to 1.3) GHz 1.3 % of reading Rate (200 Hz to 10 kHz) CW (0.15 to 10) MHz 1.3 rad Rate (200 Hz to 20 kHz) CW (0.01 to 1.3) GHz 8.8 rad Frequency - Measure1,2 Frequency Modulation – Measure Rate (20 Hz to 10 kHz) 40 kHz Peak Deviation Rate (20 Hz to 200 kHz) 400 kHz Peak Deviation Amplitude Modulation – Measure HP 8902A Measuring Receiver Phase Modulation – Measure Time and Frequency – Oscilloscopes1 Calibration Range Parameter/Equipment Expanded Uncertainty of Measurement (+/-) (1 to 24.999) mV 0.075 mV Amplitude (25 to 109.99) mV 0.17 mV Square Wave into 1 MΩ (Peak-to-Peak) 110 mV to 2.1999 V 0.049 V (2.2 to 10.999) V 0.013 V (11 to 130) V 0.15 V (1 to 24.999) mV 0.12 mV (25 to 109.99) mV 0.36 mV 10 mV to 2.1999 V (2.2 to 6.6) V 0.005 8 V 0.014 V Amplitude Square Wave into 50 Ω (Peak-to-Peak) Form 28.8—Rev 11 – 3/1/14 HP 8902A Measuring Receiver Remarks Fluke 5520A-SC600 Calibrator Fluke 5520A-SC600 Calibrator Page 11 of 12 Calibration Parameter/Equipment Rise / Fall-time 50 Ω load 5 mV to 2.5 V (Peak-to-Peak) Bandwidth relative to 50 kHz 50 Ω load Timebase 50 Ω Load Range Expanded Uncertainty of Measurement (+/-) 1 kHz to 2 MHz 350 pS 2 MHz to 10 MHz 400 pS (0.05 to 100) MHz 0.087 mV (100 to 300) MHz 0.23 mV (300 to 600) MHz 0.23 mV (0.05 to 100) MHz 0.058 V (100 to 300) MHz 0.058 V (300 to 600) MHz 0.059 V 5 s to 50 mS 0.029 S 20 mS to 2 nS 0.002 9 mS Certificate # L2151 Remarks Fluke 5520A-SC600 Calibrator Fluke 5520A-SC600 Calibrator Fluke 5520A-SC600 Calibrator Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and remarks. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%. Notes: 1) Laboratory offers calibration services at the laboratory's own facilities and at the client or other agreed upon facilities. 2) f is defined as the measured / generated frequency. Approved by: Date: May 31, 2016 R. Douglas Leonard Chief Technical Officer Re-Issued: 5/31/16 Form 28.8—Rev 11 – 3/1/14 Page 12 of 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : L-A-B Staff Create Date : 2016:05:31 08:45:40-04:00 Modify Date : 2016:06:07 12:52:23-04:00 Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : L-A-B Staff Title : Proposed Scope of Accreditation Creator Tool : Microsoft® Word 2016 Metadata Date : 2016:06:07 12:52:23-04:00 Producer : Microsoft® Word 2016 Document ID : uuid:e8e7f8d6-7528-47f0-9411-97f3f82b9469 Instance ID : uuid:518fa864-a90c-4b0b-ab38-52d9ab36f4a2 Page Count : 12EXIF Metadata provided by EXIF.tools