Tele PACE User And Reference Manual
TelePACE%20User%20and%20Reference%20Manual
User Manual:
Open the PDF directly: View PDF
Page Count: 1184 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- Ladder Logic Overview
- Ladder Logic Program Development
- TelePACE Program Development
- Ladder Logic Program Reference
- Introduction
- File Menu
- Edit Menu
- Search Menu
- Controller Menu
- Type
- Serial Ports
- IP Configuration
- Register Assignment
- Outputs On Stop
- Store and Forward
- DNP
- DNP Status
- DNP Master Status
- Initialize
- Real Time Clock
- Monitor Element
- List Force Registers
- Remove All Forces
- Lock Controller
- Unlock Controller
- Override Controller Lock
- Show Lock Status
- C/C++ Program Loader
- Flash Loader
- Program Status
- Communications Menu
- Activity Menu
- Operation Menu
- Options Menu
- Help Menu
- Ladder Logic Function Reference
- Register Types
- Ladder Logic Functions
- ABS – Absolute Value
- ABSF - Floating-Point Absolute Value
- ADD – Add Signed Values
- ADDF - Add Floating-Point Values
- ADDU – Add Unsigned Values
- AND – And Block
- CALL - Execute Subroutine
- Coil
- CMPB – Compare Bit
- CMP – Compare Signed Values
- CMPU – Compare Unsigned Values
- DCTR – Down Counter
- DEVT – Generate DNP Event
- DIAL – Control Dial-Up Modem
- DIV – Divide Signed Values
- DIVF - Divide Floating-Point Values
- DIVU – Divide Unsigned Values
- DLOG - Data Logger
- DPOL – Trigger a DNP class poll
- DSYC – Trigger a DNP clock synchronization
- DUNS – Trigger a DNP unsolicited response message
- FIN – FIFO Queue Insert
- FOUT – FIFO Queue Remove
- FLOW – Flow Accumulator
- FTOS - Floating-Point to Signed Integer
- FTOU - Floating-Point to Unsigned Integer
- GETB – Get Bit from Block
- GETL - Data Logger Extract
- GTEF – Floating-Point Greater Than or Equal
- HART – Send HART Command
- INIM – Initialize Dial-Up Modem
- L–>L – List to List Transfer
- L–>R – List to Register Transfer
- LTEF - Floating-Point Less Than or Equal
- MOD – Modulus of Signed Values
- MODU – Modulus of Unsigned Values
- MOVE – Move Block
- MSTR – Master Message
- MSIP – Master IP Message
- MUL – Multiply Signed Values
- MULF - Multiply Floating-Point Values
- MULU – Multiply Unsigned Values
- Normally Closed Contact
- Normally Open Contact
- NOT – Not Block
- One Shot Coil
- OR – Or Block
- OVER – Override Block of Registers
- PID – PID Controller
- PIDA – Analog Output PID
- PIDD – Digital Output PID
- POWR – Floating-Point Raised to Power
- PULM - Pulse Minutes
- PULS - Pulse Seconds
- PUTB – Put Bit into Block
- PUT – Put Signed Value into Registers
- PUTF - Put Floating-Point Value
- PUTU – Put Unsigned Value into Registers
- R–>L – Register to List Transfer
- ROTB – Rotate Bits in Block
- SCAL – Scale Analog Value
- Shunts
- SLP – Put Controller into Sleep Mode
- SQRF - Square Root of Floating-Point Value
- STOF - Signed Integer to Floating-Point
- SUB – Subtract Signed Values
- SUBF – Subtract Floating-Point Values
- SUBR - Start of Subroutine
- SUBU –Subtract Unsigned Values
- Timers
- TOTL – Analog Totalizer
- UCTR – Up Counter
- UTOF - Unsigned Integer to Floating-Point
- XOR – Exclusive Or Block
- Ladder Logic Register Assignment Reference
- Register Assignment Reference
- Register Assignment Specification
- Register Assignment Example
- Analog Input I/O Modules
- Analog Output I/O Modules
- Configuration I/O Modules
- CNFG Clear Protocol Counters
- CNFG Clear Serial Port Counters
- CNFG DTR Off
- CNFG 5904 HART Interface Module
- CNFG IP Settings
- CNFG LED Power Settings
- CNFG Modbus IP Interface
- CNFG Modbus IP Protocols
- CNFG Modbus/TCP Settings
- CNFG PID Control Block
- CNFG Power Mode
- CNFG Protocol Settings Method 1
- CNFG Protocol Settings Method 2
- CNFG Protocol Settings Method 3
- CNFG Real Time Clock and Alarm
- CNFG Save Settings to EEPROM
- CNFG Serial Port Settings
- CNFG Store and Forward
- Counter I/O Modules
- Diagnostic I/O Modules
- Digital Input I/O Modules
- Digital Output I/O Modules
- SCADAPack and SCADASense Series I/O Modules
- Controller Default Register Assignments
- 4202 DR Extended/4203 DR I/O Register Assignment
- SCADASense 4202/4203 DS I/O Default Register Assignment
- Micro16 Default Register Assignment (Backwards Compatible Mo
- Micro16 Default Register Assignment (Controller I/O Only)
- SCADAPack (5601 I/O Module) Default Register Assignment
- SCADAPack (5604 I/O Module) Default Register Assignment
- SCADAPack LIGHT Default Register Assignment
- SCADAPack PLUS (5601 I/O Module) Default Register Assignment
- SCADAPack Plus (5604 I/O Module) Default Register Assignment
- SCADAPack LP Default Register Assignment
- SCADAPack 350 Default Register Assignment
- SCADAPack 32 (5601 I/O Module) Default Register Assignment
- SCADAPack 32 (5604 I/O Module) Default Register Assignment
- SCADAPack 32P Default Register Assignment
- SCADAPack 100 Default Register Assignment
- Register Assignment Reference
- TeleBUS Protocols User Manual
- Table of Contents
- TeleBUS Protocols Overview
- Serial Port Configuration
- I/O Database
- Extended Station Addressing
- Slave Mode
- Modbus Master Mode
- Store and Forward Messaging
- Point–To–Point Protocol (PPP)
- TeleBUS DF1 Protocol User Manual
- Table of Contents
- TeleBUS DF1 Protocol Overview
- Serial Port Configuration
- I/O Database
- Slave Mode
- Master Mode
- DNP3 User and Reference Manual
- Using This Manual
- DNP3 Overview
- DNP Network Architectures
- Configuration of DNP Operation Modes
- DNP Configuration Menu
- Application Layer Configuration
- Data Link Layer Configuration
- Master
- Master Poll
- Address Mapping
- Routing
- Binary Inputs Configuration
- Binary Outputs Configuration
- 16–Bit Analog Inputs Configuration
- 32-Bit Analog Inputs Configuration
- Short Floating Point Analog Inputs
- 16-Bit Analog Outputs Configuration
- 32-Bit Analog Outputs Configuration
- Short Floating Point Analog Outputs
- 16–Bit Counter Inputs Configuration
- 32-Bit Counter Inputs Configuration
- DNP Diagnostics
- DNP Device Profile Document - Master
- DNP Device Profile Document - Slave
- TelePACE C Tools User Manual
- Table of Contents
- TelePACE C Tools Overview
- Getting Started
- C Program Development
- Real Time Operating System
- Overview of Programming Functions
- Controller Operation
- Controller I/O Hardware
- Analog Input Functions
- Analog Output Functions
- Digital Input Functions
- Digital Output Functions
- Counter Input Functions
- Status LED and Output Functions
- Options Switches Functions
- LED Indicators Functions
- LED Power Control Functions
- Software Timer Functions
- Real Time Clock Functions
- The Jiffy Clock
- Watchdog Timer Functions
- Checksum Functions
- Serial Communication
- Communication Protocols
- DNP Communication Protocol
- I/O Database
- HART Communication
- PID Control
- Backward Compatibility Functions
- TelePACE C Tools Function Specifications
- addRegAssignment
- addRegAssignmentEx
- ain
- aioError
- alarmIn
- allocate_envelope
- aout
- auto_pid
- check_error
- checksum
- checkSFTranslationTable
- clearAllForcing
- clear_errors
- clear_pid
- clear_protocol_status
- clearRegAssignment
- clearSFTranslationTable
- clearStatusBit
- clear_tx
- counter
- counterError
- crc_reverse
- create_task
- databaseRead
- databaseWrite
- datalogCreate
- datalogDelete
- datalogPurge
- datalogReadNext
- datalogReadStart
- datalogRecordSize
- datalogSettings
- datalogWrite
- dbase
- deallocate_envelope
- din
- dnpInstallConnectionHandler
- dnpClearEventLog
- dnpConnectionEvent
- dnpCreateRoutingTable
- dnpGenerateEventLog
- dnpGetAI16Config
- dnpGetAI32Config
- dnpGetAISFConfig
- dnpGetAO16Config
- dnpGetAO32Config
- dnpGetAOSFConfig
- dnpGetBIConfig
- dnpGetBIConfigEx
- dnpGetBOConfig
- dnpGetCI16Config
- dnpGetCI32Config
- dnpGetConfiguration
- dnpGetConfigurationEx
- dnpGetRuntimeStatus
- dnpReadRoutingTableDialStrings
- dnpReadRoutingTableEntry
- dnpReadRoutingTableSize
- dnpSaveAI16Config
- dnpSaveAI32Config
- dnpSaveAISFConfig
- dnpSaveAO16Config
- dnpSaveAO32Config
- dnpSaveAOSFConfig
- dnpSaveBIConfig
- dnpSaveBIConfigEx
- dnpSaveBOConfig
- dnpSaveCI16Config
- dnpSaveCI32Config
- dnpSaveConfiguration
- dnpSaveConfigurationEx
- dnpSearchRoutingTable
- dnpSendUnsolicited
- dnpSendUnsolicitedResponse
- dnpWriteRoutingTableEntry
- dnpWriteRoutingTableDialStrings
- dout
- end_application
- end_task
- endTimedEvent
- enronInstallCommandHandler
- forceLed
- getABConfiguration
- getBootType
- getclock
- getClockAlarm
- getClockTime
- getControllerID
- getForceFlag
- getIOErrorIndication
- getOutputsInStopMode
- getPortCharacteristics
- getPowerMode
- get_pid
- get_port
- getProgramStatus
- get_protocol
- getProtocolSettings
- getProtocolSettingsEx
- get_protocol_status
- getSFMapping
- getSFTranslation
- get_status
- getStatusBit
- getTaskInfo
- getVersion
- getWakeSource
- hartIO
- hartIOFromDbase
- hartCommand
- hartCommand0
- hartCommand1
- hartCommand2
- hartCommand3
- hartCommand11
- hartCommand33
- hartStatus
- hartGetConfiguration
- hartSetConfiguration
- hartPackString
- hartUnpackString
- install_handler
- installClockHandler
- installExitHandler
- installModbusHandler
- Handler Function
- installRTCHandler
- RTCHandler Function
- interruptCounter
- interruptInput
- RTCHandler Function
- interrupt_signal_event
- interval
- ioBusReadByte
- ioBusReadLastByte
- ioBusReadMessage
- ioBusSelectForRead
- ioBusSelectForWrite
- ioBusStart
- ioBusStop
- ioBusWriteByte
- ioBusWriteMessage
- ioClear
- ioDatabaseReset
- ioRead16Din
- ioRead32Din
- ioRead4Ain
- ioRead4Counter
- ioRead4202Inputs
- ioRead4202DSInputs
- ioRead5505Inputs
- ioRead5506Inputs
- ioRead5601Inputs
- ioRead5602Inputs
- ioRead5604Inputs
- ioRead5606Inputs
- ioRead8Ain
- ioRead8Din
- ioReadLPInputs
- ioReadSP100Inputs
- ioRefresh
- ioReset
- ioWrite16Dout
- ioWrite32Dout
- ioWrite8Dout
- ioWrite2Aout
- ioWrite4Aout
- ioWrite4AoutChecksum
- ioWrite4202Outputs
- ioWrite4202OutputsEx
- ioWrite4202DSOutputs
- ioWrite5303Aout
- ioWrite5505Outputs
- ioWrite5506Outputs
- ioWrite5601Outputs
- ioWrite5602Outputs
- ioWrite5604Outputs
- ioWrite5606Outputs
- ioWriteLPOutputs
- ioWriteSP100Outputs
- jiffy
- ledGetDefault
- ledPower
- ledPowerSwitch
- ledSetDefault
- load
- master_message
- modbusExceptionStatus
- modbusSlaveID
- modbusProcessCommand Function
- modemAbort
- modemAbortAll
- modemDial
- modemDialEnd
- modemDialStatus
- modemInit
- modemInitEnd
- modemInitStatus
- modemNotification
- off
- on
- optionSwitch
- overrideDbase
- pollABSlave
- poll_event
- poll_message
- poll_resource
- portConfiguration
- portIndex
- portStream
- processModbusCommand
- pulse
- pulse_train
- queue_mode
- readCounter
- readCounterInput
- readBattery
- readInternalAD
- readStopwatch
- readThermistor
- read_timer_info
- receive_message
- release_processor
- release_resource
- report_error
- request_resource
- resetAllABSlaves
- resetClockAlarm
- route
- runLed
- save
- send_message
- setABConfiguration
- setBootType
- setclock
- setClockAlarm
- setdbase
- setDTR
- setForceFlag
- setIOErrorIndication
- setjiffy
- setOutputsInStopMode
- set_pid
- set_port
- setPowerMode
- setProgramStatus
- set_protocol
- setProtocolSettings
- setProtocolSettingsEx
- setSFMapping
- setSFTranslation
- setStatus
- setStatusBit
- settimer
- setWakeSource
- signal_event
- sleep
- start_protocol
- startup_task
- startTimedEvent
- timeout
- timeoutCancel
- timeoutRequest
- timer
- turnoff
- turnon
- wait_event
- wd_auto
- wd_manual
- wd_pulse
- TelePACE C Tools Macro Definitions
- TelePACE C Tools Structures and Types
- ABConfiguration
- ADDRESS_MODE
- ALARM_SETTING
- clock
- DATALOG_CONFIGURATION
- DATALOG_STATUS
- DATALOG_VARIABLE
- DialError
- DialState
- dnpAnalogInput
- dnpAnalogOutput
- dnpBinaryInput
- DNP Binary Input Extended Point
- dnpBinaryOutput
- DNP_CONNECTION_EVENT Type
- dnpConfiguration
- dnpConfigurationEx
- dnpCounterInput
- dnpPointType
- DNP_RUNTIME_STATUS
- envelope
- HART_COMMAND
- HART_DEVICE
- HART_RESPONSE
- HART_RESULT
- HART_SETTINGS
- HART_VARIABLE
- ioModules
- ledControl_tag
- ModemInit
- ModemSetup
- PROTOCOL_SETTINGS
- PROTOCOL_SETTINGS_EX Type
- prot_settings
- prot_status
- pconfig
- PORT_CHARACTERISTICS
- pstatus
- READSTATUS
- regAssign
- routingTable
- SFTranslation
- SFTranslationStatus
- TASKINFO
- taskInfo_tag
- timer_info
- VERSION
- WRITESTATUS
- C Compiler Known Problems
- TelePACE C Tools Warranty and License
- Ladder Logic Modem Commands