INTEGRAL¿ Self Protected Combination Motor Controllers Telemecanique Integral 32 Starter
User Manual: Telemecanique-Integral-32-Motor-Starter Igor's of metalworking and electrical manuals
Open the PDF directly: View PDF .
Page Count: 52
Download | |
Open PDF In Browser | View PDF |
INTEGRAL™ Self-Protected Combination Motor Controllers Class 8539 CONTENTS Schneider Electric Brands Description Page Product Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Application and General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-27 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-41 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-46 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47-51 INTEGRAL™ Self-Protected Combination Motor Controllers 2 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Product Description COMBINATION MOTOR CONTROL IN ONE COMPACT PACKAGE! The INTEGRAL™ Self-Protected Combination Motor Controller (CMC) combines all the functions of a disconnect, circuit breaker, contactor, and overload relay in a coordinated motor controller. A wide variety of easy-toinstall auxiliary blocks and interface modules provides powerful communication and control capabilities. As much as 60% less panel space is required by the INTEGRAL CMC as compared to traditional combination motor control circuit installations. In addition, installation and wiring time is dramatically reduced — simply snap the INTEGRAL onto a 35 mm DIN rail and connect load and line side wires. Integral 18 The entire family of INTEGRAL CMCs have proven their reliability and effectiveness in thousands of applications worldwide. By installing the INTEGRAL Self-Protected CMC, you are implementing the latest in motor control and protection technology, and assuring the lowest installed cost of any motor control scheme. Features • Non-reversing and reversing combination motor controllers available in 18, 32, or 63 ampere ratings. • NEMA Type 1 and 12 enclosed combination motor controllers and open style combination motor controllers both available. • Current-limiting short-circuit protection provides 42 kA interrupt rating. • UL listed as a Type E combination motor controller. • UL verified to meet “Type 2” coordination protection per IEC 947-4. • Meets “Total Coordination” requirements of IEC 947-6 — no damage to contactor or overload relay, and no welding of contacts after interruption of short-circuit faults. Integral 32 • Padlockable isolation knob. • Minimum 1.5 million operation life expectancy. • Proven reliability — even after exposure to multiple short-circuit faults! • Control direct from PLC or PC with optional interface modules. Integral 63 01/00 © 2000 Schneider Electric All Rights Reserved 3 INTEGRAL™ Self-Protected Combination Motor Controllers Product Description INTEGRAL 18 INTEGRAL 32 LD1LB030• + LB1LB03P•• Rated Operational Current for AC-3 Duty LD5LB030• + LB1LB03P•• LD1LC030• + LB1LC03M•• LD4LC030• + LB1LC03M•• 18 A 32 A Rated Breaking Capacity 42 KA at 480 Vac 42 KA at 480 Vac Approvals ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE Number of Poles 3 3 Protection Module LB1LB03P•• LB1LC03M•• Magnetic Protection Fixed, 15 times maximum thermal current Overload Protection 0.1 to 0.16 A: P01 4 LD5LC130• + LB1LC03M•• Adjustable, 6 to 12 times maximum thermal current 0.16 to 0.25 A P02 0.25 to 0.4 A P03 0.25 to 0.4 A M03 0.4 to 0.63 A P04 0.4 to 0.63 A M04 0.63 to 1.0 A P05 0.63 to 1.0 A M05 1.0 to 1.6 A P06 1.0 to 1.6 A M06 1.6 to 2.5 A P07 1.6 to 2.5 A M07 2.5 to 4.0 A P08 2.5 to 4.0 A M08 4.0 to 6.0 A P10 4.0 to 6.3 A M10 6.0 to 10.0 A P13 6.3 to 10.0 A M13 10.0 to 16.0 A P17 10.0 to 16.0 A P17 12.0 to 18.0 A P21 – – 16.0 to 25.0 A M22 – 23.0 to 32.0 A M23 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Product Description INTEGRAL 63 LD1LC030• + LB1LC03M•• Rated Operational Current for AC-3 Duty LD4LC030• + LB1LC03M•• LD5LC130• + LB1LC03M•• 63 A Rated Breaking Capacity 42 KA at 480 Vac Approvals ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE Number of Poles 3 Protection Module LB1LD03M•• Magnetic Protection Adjustable, 6 to 12 times maximum thermal current Overload Protection 01/00 10.0 to 13.0 A M16 13.0 to 18.0 A M21 18.0 to 25.0 A M22 23.0 to 32.0 A M53 28.0 to 40.0 A M55 35.0 to 50.0 A M57 45.0 to 63.0 A M61 © 2000 Schneider Electric All Rights Reserved 5 INTEGRAL™ Self-Protected Combination Motor Controllers Selection To order an INTEGRAL CMC, complete these four steps: 1. Select the correct combination motor controller from Table 1A (open) or Table 1B (enclosed). 2. Complete the catalog number by adding the coil voltage code from Table 2. 3. Choose the appropriate protection module from Table 3. 4. For enclosed combination motor controllers only, select any desired INSTA-KITS™ or factory modifications from Table on page 20. For factory modification, add the “form” number to the end of the catalog number. Table 1A: Open Style INTEGRAL CMC Base Unit Selection Table LD1LB030• Continuous Current Rating Maximum 3-Phase HP Rating Amperes With Isolator Without Isolator Catalog Number Catalog Number 230 V 460 V 575 V 18 5 10 15 LD1LB030* N/A 32 10 20 30 LD4LC030* LD1LC030 ● 63 20 40 60 LD4LD030* LD1LD030 ● 18 5 10 15 LD5LB130* N/A 32 10 20 30 LD5LC030* N/A 63 20 40 60 LD5LD030* N/A Type 1 Enclosure Type 12 Enclosure Catalog Number Non-Reversing Reversing LD5LB130• Table 1B: Enclosed INTEGRAL CMC Selection Table Continuous Current Rating Maximum 3-Phase HP Rating Amperes 230 V 460 V 575 V Catalog Number 18 5 10 15 LE1UI1846 ● LE1UI1847 ● 32 10 20 20 LE1UI3246 ● LE1UI3247 ● 63 20 40 60 LE1UI6346 ● LE1UI6347 ● Non-Reversing Reversing LD4LC030• ● 18 5 10 15 LE2UI1846 ● LE2UI1847 ● 32 10 20 20 LE2UI3246 ● LE2UI3247 ● 63 20 40 60 LE2UI6346 ● LE2UI6347 ● Complete the catalog number by adding the voltage code from Table 2 Table 2: Coil Voltage Codes Control Voltage INTEGRAL I18 LD5LC030• I32 I63 ■ Frequency Hz 24 48 110 120 220 240 380 415 480 600 50 B E F - M U Q N - - 60 BC D K FC LC MC - - N S DC ■ BD - - - - - - - - - 50 B E F - M U Q N - - 60 BC D FC FC MC MC - - Q S DC ■ BD ED FD - - - - - - - 50 B E F - M U Q N - - 60 BC CE K FC LC MC - - Q S DC ■ BD ED FD - - - - - - - INTEGRAL Base Units ordered with DC voltage code (BD, ED or FD) are shipped with LA1L*080*D Voltage Converter Module already installed. Enclosed Product Open Product Open INTEGRAL CMC Dimensions . . . . . . . . . . page 48 Enclosed INTEGRAL CMC Dimensions . . . . . . . page 51 File E164871 CCN NKJH NKJH7 File E163364 CCN NKJH NKJH7 File LR 43364 Class 3211 08 File LR 105062 Class 3211 08 LD4LD030• 6 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Selection Table 3: Overload Protection Modules (Class 10, Ambient Compensated) Thermal Setting Range, Amperes c Magnetic Setting Range, Amperes Standard Module with Thermal & Magnetic Trip Catalog No. Magnetic only Module N/A For 18 Ampere models LB1LB03P05 0.1 - 0.16 – LB1LB03P01 0.16 - 0.25 – LB1LB03P02 N/A 0.25 - 0.4 – LB1LB03P03 N/A 0.4 - 0.63 – LB1LB03P04 N/A 0.63 - 1 – LB1LB03P05 N/A 1 - 1.6 – LB1LB03P06 N/A 1.6 - 2.5 – LB1LB03P07 N/A 2.5 - 4 – LB1LB03P08 N/A 4-6 – LB1LB03P10 N/A 6 - 10 – LB1LB03P13 N/A 10 - 16 – LB1LB03P17 N/A 12 - 18 – LB1LB03P21 N/A 0.25 - 0.40 2.4 - 4.8 LB1LC03M03 LB6LC03M03 0.40 - 0.63 3.8 - 7.6 LB1LC03M04 LB6LC03M04 0.63 - 1.0 6.0 - 12 LB1LC03M05 LB6LC03M05 1.0 - 1.6 9.5 - 19 LB1LC03M06 LB6LC03M06 1.6 - 2.5 15 - 30 LB1LC03M07 LB6LC03M07 2.5 - 4.0 24 - 48 LB1LC03M08 LB6LC03M08 4.0 - 6.3 38 - 76 LB1LC03M10 LB6LC03M10 6.3 - 10 60 - 120 LB1LC03M13 LB6LC03M13 10 - 16 95 - 190 LB1LC03M17 LB6LC03M17 16 - 25 150 - 300 LB1LC03M22 LB6LC03M22 23 - 32 190 - 380 LB1LC03M53 LB6LC03M53 18 - 25 150 - 300 LB1LD03M22 LB6LD03M22 23 - 32 190 - 380 LB1LD03M53 LB6LD03M53 28 - 40 240 - 480 LB1LD03M55 LB6LD03M55 35 - 50 300 - 600 LB1LD03M57 LB6LD03M57 45 - 63 380 - 760 LB1LD03M61 LB6LD03M61 For 32 Ampere models LB1LC03M22 For 63 Ampere models c LB1LD03M57 Thermal settings are based on motors with a service factor (S.F.) of 1.0. Specifications Operating Positions: UL Listed and CSA certified 30° Conforms to IEC standards 90 ° 90 ° 30° Shock resistance - 8 g (Duration of impulse: 11 ms) Vibration resistance - 3 g (5 to 150 Hz) AC control circuit temperature limits: Storage -40 to +176 °F/-40 to +80 °C Rated voltage - 600 Vac Operation -13 to +104 °F/-25 to +70 °C Rated thermal current - 18 A (INTEGRAL 18), 32 A (INTEGRAL 32), 63 A (INTEGRAL 63) Interrupting current at 480 Vac: 42 kA ms INTEGRAL 18 INTEGRAL 32 INTEGRAL 63 File E164871 CCN NKJH NKJH7 01/00 Fixed magnetic trip is set at approximately 15 times full load current (FLC) Mechanical life: 20 million operations 10 million operations 5 million operations Operating current of magnetic trip is approximately 15 times maximum thermal trip (non-adjustable setting) File LR 43364 Class 3211 08 © 2000 Schneider Electric All Rights Reserved 7 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18 Accessories AUTO TRIP. + O LA1LB019 LA1LB001 AUTO TRIP. + O LD5LB LA1LB017 LA1LB001 LA1LB021 AUTO LA1LB0311 TRIP. + O LA1LB015 LD1LB LA1LB0211 LA1LB034 LA1LB031 LA1LB0341 8 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18 Accessories Auxiliary Contact Blocks for the INTEGRAL 18 CMC For Use On Mounting Location Contact Type Catalog Number Right Side Block of 5 instantaneous contacts 3 signal “contactor state” 2 signal “tripped” status 2 N/O + 1 N/C 1 N/O + 1 N/C LA1LB015 Right Side Block of 3 instantaneous contacts 2 signal “contactor state” 1 signal “tripped” status 1 N/O + 1 N/C 1 N/O LA1LB017 Right Side Block of 3 instantaneous contacts 2 signal “contactor state” 1 signal “tripped” status 1 N/O + 1 N/C 1 N/C LA1LB019 Left or Right Side Complementary auxiliary block 1 signal “contactor state” 1 N/C LA1LB001a Left Side 2 signal operating handle not in “Auto” position 2 N/O LA1LB031 Left Side 2 signal operating handle not in “Auto” position 1 N/O + 1 N/C LA1LB0311 Left Side Block of 3 instantaneous contacts 2 signal operating handle not in “Auto” position 2 signals “tripped on short circuit” status 2 N/O 1 N/O + 1 N/C LA1LB034 Left Side Block of 3 instantaneous contacts 2 signal operating handle not in “Auto” position 2 signals “tripped on short circuit” status 1 N/O + 1 N/C 1 N/O + 1 N/C LA1LB0341 Left Side Block of 5 instantaneous contacts 3 signal “contactor state” 2 signal operating handle not in “Auto” position 2 N/O + 1 N/C 2 N/O LA1LB021 Left Side Block of 5 instantaneous contacts 3 signal “contactor state” 2 signal operating handle not in “Auto” position 2 N/O + 1 N/C 1 N/O + 1 N/C LA1LB0211 LD1 or LD5 LD1LB03FC + LB1LB03P01 LD1 Type and Number of Contacts per Block LD5 a Use of auxiliary contact LA1LB001 requires combination with contact block LA1LB015, LA1LB021, LA1LB017, or LA1LB019. File E164871 CCN NKJH NKJH7 File LR 43364 Class 3211 08 01/00 © 2000 Schneider Electric All Rights Reserved 9 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32/63 Accessories AU TO TR IP. + O AUTO TRIP. + LA1LC020 SET RE LA1LC021 LA1LC031 LA1LC07 LD5LC,LD ●● LA1LC001 LA1LC012 LA1LC052 ● AUTO TRIP. + O LA1LC030 (LD4) LA1LC030 (LD4) LA1LC001 LD1LC,LD LD4LC,LD LA1LC010 LA1LC025 10 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32/63 Accessories Auxiliary Contact Blocks for the INTEGRAL 32/63 CMC For Use On Mounting Location Right Side Type and Number of Contacts per Block Contact Type Catalog Number 2 N/O + 1 N/C 1 N/O-N/C (form C contact) 1 N/O-N/C Block of 6 instantaneous contacts 3 signal “contactor state” 1 signal “tripped on short circuit” 1 signal “tripped” 1 signal “not in Auto position” LA1LC010 (form C contact) 1 N/O-N/C (form C contact) Right Side Block of 5 instantaneous contacts 3 signal “contactor state” 1 signal “tripped on short circuit” 1 signal “tripped” 2 N/O + 1 N/C 1 N/O 1 N/O LA1LC012 Right Side Block of 4 instantaneous contacts 3 signal “contactor state” 1 signal “tripped” 2 N/O + 1 N/C 1 N/O or 1 N/C, User Selectable LA1LC025 Right Side Block of 3 instantaneous contacts 3 signal “contactor state” 2 N/O + 1 N/C LA1LC020 Left or Right Side Complementary auxiliary block 1 signal “contactor state” 1 N/C LA1LC001q Left Side Block of 1 “control circuit isolation” contact 1 N/O LA1LC030 Left Side Block of 3 instantaneous contacts 3 signal “contactor state” 2 N/O + 1 N/C LA1LC021 Left Side Block of 2 “control circuit isolation” contact 2 N/O LA1LC031q LD1, LD4 or LD5 LA1LC030 LD4 LD5 See table below. q LA1LC012 Complementary blocks LA1LC001 and LA1LC031, as well as LA1LC052** reset modules and LA1LC07** trip modules on page 12 must be used with an additional auxiliary block. This following table shows all allowable combinations. Possible Combinations of Auxiliary Contact Blocks for the INTEGRAL 32/63 CMC LA1LC001 LC4LC030+ LB1LC03M22+ LA1LC030+ LA1LC010+ LA1LC070F LA1LC010 Block of 6 auxiliary contacts Right Side LA1LC012 Block of 5 auxiliary contacts Right Side √f LA1LC025 Block of 4 auxiliary contacts Right Side √ LA1LC021 Block of 3 auxiliary contacts Left Side √t LA1LC07** LA1LC052* √ √ √ √f LA1LC031 √t Only one attachment may be added -- either LA1LC001 or LA1LC052 Only one attachment may be added -- either LA1LC001 or LA1LC031 f t ® File E164871 CCN NKJH NKJH7 File LR 43364 Class 3211 08 3211 04 01/00 © 2000 Schneider Electric All Rights Reserved 11 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32/63 Accessories AU TO TR IP. + O AUTO TRIP. + LA1LC020 T RESE LA1LC021 LA1LC031 LA1LC07 LD5LC,LD ●● LA1LC001 LA1LC012 LA1LC052 ● AUTO TRIP. + O LA1LC030 (LD4) LA1LC030 (LD4) LA1LC001 LD1LC,LD LD4LC,LD LA1LC010 LA1LC025 12 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32/63 Accessories The shunt and undervoltage trip modules are for use with any 32 A or 63 A INTEGRAL CMC fitted with either an LA1LC010 or LA1LC012 add-on block. Shunt and Undervoltage Trip Modules Description Trip Specifications Catalog Number Time Delay (0.2 seconds) LA1LC070k Instantaneous LA1LC072k Instantaneous LA1LC071k Undervoltage Trip Module LA1LC070F Shunt Trip Module k Complete the catalog number with the letter shown below for the required coil voltage Volts 24 48 110 120 220 240 380 415 440 50 Hz B E F - M U Q N N 60 Hz B E F F M M Q - N The remote reset modules are for use with any 32 A or 63 A INTEGRAL CMC fitted with either an LA1LC010 or LA1LC012 add-on block. Remote Reset Modules Description LA1LC052F Control Voltage Catalog Number 24 V 50/60 Hz LA1LC052B 42 V 50 Hz 48 V 50/60 Hz LA1LC052E 100/127 V 50/60 Hz LA1LC052F 200/240 V 50/60 Hz LA1LC052M Remote Reset Module ■ When adding a remote reset module to a LE•UI••• enclosed device (page 6), an oversized enclosure is required. ■ ® File E164871 CCN NKJH NKJH7 File LR 43364 Class 3211 08 01/00 © 2000 Schneider Electric All Rights Reserved 13 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Accessories LA9D09982 LA4DA2 LA4DE2 ● ● AUTO TRIP. + LA4DR ●U O LA4DM ● LA4DL LA4DT ● ●U LA1LB080BD LA4DWB LA4DF ● AUTO TRIP. + O AUTO LD5LB TRIP. + O LD1LB LA9D09982 LA1L ● 080 ● D LA1L ● 180BD LA1L ● 580 ● D AUTO TRIP. + T RESE AUTO TRIP. LD5LC,LD + O LD1LC,LD LD4LC,LD 14 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Accessories The top-mounted, add-on voltage converter modules are required to allow operation of an INTEGRAL CMC with DC control voltage. The converters may only be used with the coils shown in the table below. NOTE: When INTEGRAL CMCs are factory ordered with a DC coil code (from Table 1A / 1B and Table 2, Page 6), these converter modules need not be ordered separately. Voltage Converter Modules c a Description Nominal Voltage For Use With Coils INTEGRAL 18 Converter Module 24 Vdc LX1LB024 LA1LB080BD 24 Vdc LX1LC0249 LA1LC080BD 48 Vdc LX1LC0489 LA1LC080ED 110 Vdc LX1LC1109 LA1LC080FD 24 Vdc LX1LD0249 LA1LD080BD 48 Vdc LX1LD0489 LA1LD080ED 110 Vdc LX1LD1109 LA1LD080FD INTEGRAL 32 Converter Module INTEGRAL 63 Converter Module LA1LC180BD c a Catalog Number When using a rectified AC supply, ripple must not exceed 14%. Reversing INTEGRAL CMCs require use of two converter modules. The interface modules allow INTEGRAL CMCs to be energized from low voltage and low current signals. Solid state and mechanical relay versions are both available. The “relay plus manual override” version includes a slide switch for manually energizing the contactor. Interface Modules Operational Voltage Catalog Number 5 to 24 Vdc 24 to 250 Vac LA4DWB 24 Vdc 24 to 250 Vac LA4DFB 48 Vdc 24 to 250 Vac LA4DFE 24 Vdc 24 to 250 Vac LA4DLB Mechanical Relay plus manual override 48 Vdc 24 to 250 Vac LA4DLE Solid State Relay 5 to 24 Vdc 24 to 240 Vac LA1LC180BD 24 Vdc 24 to 240 Vac LA1LC580BD LA1LC580ED Description q Type Input Voltage INTEGRAL 18 Interface Module Solid State Relay ® File E164871 CCN NKJH NKJH7 File LR 43364 Class 3211 08 Mechanical Relay INTEGRAL 32 Interface Module Mechanical Relay Solid State Relay 48 Vdc 24 to 240 Vac 5 to 24 Vdc 24 to 240 Vac LA1LD180BD 24 Vdc 24 to 240 Vac LA1LD580BD 48 Vdc 24 to 240 Vac LA1LD580ED INTEGRAL 63 Interface Module Mechanical Relay q 01/00 Reversing INTEGRAL CMCs require use of two interface modules. © 2000 Schneider Electric All Rights Reserved 15 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Accessories LA9D09982 LA4DA2 ● LA4DE2 ● AUTO TRIP. + LA4DR● U O LA4DM ● LA4DL ● LA4DT● U LA1LB080BD LA4DWB LA4DF ● AUTO TRIP. + O AUTO TRIP. LD5LB + O LD1LB LA9D09982 LA1L● 080 ● D LA1L● 180BD LA1L● 580 ● D AUTO TRIP. + T RESE AUTO TRIP. LD5LC,LD + O LD1LC,LD LD4LC,LD 16 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Accessories The control modules allow local or remote operation of the 18 A INTEGRAL CMC. The module includes a slide switch to change from automatic (remote) operation to manual (local) operation. When in manual mode, a separate dial allows the user to locally energize and de-energize the combination motor controller. “Automatic - Manual - Stop” Control Module (for INTEGRAL 18 only) Description Control Voltage Auto- Manual-Stop Module LA4DMU Catalog Number 24 - 100 Vac LA4DMK 100 - 250 Vac LA4DMU These electronic timer modules delay the energization or de-energization of the 18 ampere INTEGRAL CMC. Electronic Timer Module (for INTEGRAL 18 only) Description On-Delay Timer Module LA4DROU Off-Delay Timer Module Time Delay Operational Voltage c 50/60 Hz AC Catalog Number 0.1 to 2 sec. 24 to 240 Vac LA4DT0U 1.5 to 30 sec. 24 to 240 Vac LA4DT2U 25 to 500 sec. 24 to 240 Vac LA4DT4U 0.1 to 2 sec. 24 to 240 Vac LA4DR0U 1.5 to 30 sec. 24 to 240 Vac LA4DR2U 25 to 500 sec. 24 to 240 Vac LA4DR4U c For 24 Vac operation, INTEGRAL CMCs requires a 21 volt coil, see coil table page 19. The coil suppressor modules reduce electrical noise generated by operation of the INTEGRAL CMC. Coil Suppressor Modules Description For Use With Operational Voltage 50/60 Hz AC LA4DA2U RC Circuit 18A INTEGRAL Varistor 18A INTEGRAL RC Circuit 18A, 32A, 63A INTEGRAL Catalog Number 24 to 48 Vac LA4DA2E 50 to 127 Vac LA4DA2G 110 to 250 Vac LA4DA2U 24 to 48 Vac LA4DE2E 50 to 127 Vac LA4DE2G 110 to 250 Vac LA4DE2E 24 to 250 Vac LA9D09982 File E164353 CCN NKJH ® File LR 43364 Class 3211 03 01/00 © 2000 Schneider Electric All Rights Reserved 17 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Accessories Other Accessories Description Control Knob Padlocking Kit Control Circuit Test Device Usage Catalog Number Attaches to front face of INTEGRAL 18 to allow attachment of up to 3 padlocks LA9LB390 Used on INTEGRAL 18 only LA9LB398 To mount I18 or I32 on two 32 mm Omega rails LA9LC010 LA9LB930 Mounting Plate To mount I32 on one 75mm or two 32mm Omega rails LA9LC012 To mount I63 on one 75mm Omega rail LA9LD010 DIN Rail, 35 mm AM1DE200 DIN Rail, 75 mm AM1DL201 . Connection Accessories (INTEGRAL 18 Units Only) Description GV1G09 Catalog Number Set of 63 A 3-pole busbars to supply an additional INTEGRAL LA9LB930 (2) Terminal to supply one or more LA9LB930 busbar sets; cables connected to top GV1G09 (1) Terminal to supply one or more LA9LB930 busbar sets; cables connected to bottom LA9LB960 (2) Through the Door Operators (IP54) Description For Use With Knob Color Catalog Number Red LA9LB330 Black LA9LB331 I18 (LD1 or LD5) Adjustable Depth Operator t (from 0 to 185mm depth) Red LA9LC330 Black LA9LC331 I32, I63 (LD1) Red LA9LC530 Black LA9LC531 I32, I63 (LD4 or LD5) LA9LB960 Red LA9LB320 Black LA9LB321 Red LA9LC320 Black LA9LC321 Red LA9LC520 Black LA9LC521 I18 (LD1 or LD5) Fixed Depth Operator t I32, I63 (LD1) I32, I63 (LD4 or LD5) t LA9LC701 See page 49 for mounting dimensions. Protection Accessories Description Finger Protection Cover for power terminals (L1, L2, L3) For use with Sold in Lots of INTEGRAL 32 5 Catalog Number LA9LC701 INTEGRAL 63 5 LA9LD701 INTEGRAL 18 1 LA1LB090 INTEGRAL 32 or 63 1 LA1LC090 Anti-tamper cover for: protection module LB ■ protection module LC or LD LA9Lk090 ■ For use with trip modules manufactured after January 1, 1998. (1) File E164864 CCN NLRV ® ® File LR 81630 Class 3211 05 18 (2) © 2000 Schneider Electric All Rights Reserved File E164871 CCN NKJH NKJH7 File LR 43364 Class 3211 08 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Accessories AC Coils Nominal Voltage DC Coils c 60 Hz Coil Cat. No. 50 Hz Coil Cat. No. 18 A Models Nominal Voltage Converter Cat. No. DC Coil Cat. No. LA1LB080BD LX1LB024 18 A model 21 LX1LB019 LX1LB021 24 24 LX1LB021 LX1LB024 36 LX1LB032 – 24 LA1LC080BD LX1LC0249 42 – LX1LB042 48 LA1LC080ED LX1LC0489 48 LX1LB042 LX1LB048 110 LA1LC080FD LX1LC1109 110 LX1LB100 LX1LB110 115/120 LX1LB105 – 24 LA1LD080BD LX1LD0249 127 – LX1LB127 48 LA1LD080ED LX1LD0489 220 LX1LB200 LX1LB220 110 LA1LD080FD LX1LD1109 32 A models LX1LBkkk LX1LCkkk 230/240 LX1LB210 – 240 – LX1LB240 380 – LX1LB380 415 – LX1LB415 440 LX1LB380 LX1LB440 460/480 LX1LB415 – 500 – LX1LB500 575/600 LX1 LB500 – 660 – LX1LB660 24 LX1LC020 LX1LC024 110 - LX1LC110 120 LX1LC100 - 220 LX1LC190 LX1LC220 240 LX1LC190 LX1LC240 480 LX1LC380 - 24 LX1LD020 LX1LD024 110 LX1LD090 LX1LD110 120 LX1LD100 - 220 LX1LD180 LX1LD220 240 LX1LD190 LX1LD240 480 LX1LD380 - 63 A models c INTEGRAL CMCs can operate on D.C. control voltage when fitted with a coil and converter from the table above. 32 A models LX1LDkkk 63 A models 01/00 © 2000 Schneider Electric All Rights Reserved 19 INTEGRAL™ Self-Protected Combination Motor Controllers Accessories Pilot devices and control transformers for enclosed INTEGRAL CMCs can be ordered in one of two convenient ways. Telemecanique INSTA-KITS™ may be installed at our factory by attaching the form number suffix from the table below to the end of the catalog number selected in Table 1B on page 6. Alternatively, the INSTA-KIT may be ordered separately by choosing the appropriate catalog number from the right-most column below. INSTA-KITS are easily installed in the field by removing the existing cover plate on the enclosure, installing the INSTA-KIT plate, and plugging the pre-terminated wires into its mating connector. Table 4: INSTA-KITS™ Selection. Factory-Installed Form Numbera Description On/Off Selector Switch C6 Hand-Off-Auto Selector Switch C Green Pilot Light LA9C6 LA9C P2 q LA9P12 q Red Pilot Light P1 q LA9P12 q Green Transformer Pilot Light P52 q LA9P5152* c q Red Transformer Pilot Light P51 q LA9P5152* c q Start/Stop Pushbutton LA9C6P12 INSTA-KIT Catalog Number A LA9A Start/Stop (Mushroom Head) Pushbuttons A22 LA9A2 I/O (Start/Stop) Pushbutton A6 — On/Off Selector Switch with Green Pilot Light C6P2 LA9C6P12 On/Off Selector Switch with Red Pilot Light C6P1 LA9C6P12 Hand-Off-Auto Selector Switch with Green Pilot Light CP2 LA9CP12 Hand-Off-Auto Selector Switch with Red Pilot Light CP1 LA9CP12 H-O-A Selector Switch with Green Transformer Pilot Light CP52 LA9CP5152t c H-O-A Selector Switch with Red Transformer Pilot Light CP51 Forward-Reverse-Stop Pushbuttons LA9CP5152t c A1 LA9A1 Start/Stop Pushbutton with Green Pilot Light AP2 LA9AP12 Start/Stop Pushbutton with Red Pilot Light AP1 LA9AP12 Start/Stop Pushbutton with Green Transformer Pilot Light AP52 LA9AP5152t c Start/Stop Pushbutton with Red Transformer Pilot Light AP51 LA9AP5152t c 50 VA Transformer (Standard size for INTEGRAL 18 and 32) FF4TKF50f LA9FF4TKF50f 100 VA Transformer (Extra capacity for I18 or I32; Std. capacity for I63) FF4TKF100f LA9FF4TKF100f 150 VA Transformer (Extra capacity for INTEGRAL 63) FF4TKF150f LA9FF4TKF150f Standard Control Transformer with Top Mounted Fuse Block: All except Transformers ® File E14839 CCN NKCR NKCR7 File LR 105062 Class 3211 02 Local/Remote Adapter - Three Wire q — LA93W Local/Remote Adapter - Four Wire q — LA94W Local/Remote Adapter - Five Wire q — LA95W Local/Remote Adapter - Seven Wire q — LA97W Fuse Kit for Remote e — LA9FK f c Transformers ® File E 61239 CCN XPTQ XPTQ7 a q e 20 Complete the form number or catalog number with one of the following voltage codes: Voltage D1 D2 D3 D14 Primary 480/240 480/240 208 208 D33 380/400/415 Secondary 120 24 120 24 115/230 Replace t with the suffix letter corresponding to the pilot light voltage. Voltage 24 V 120 V 208/240 V 480 V Suffix Letter B K P W For factory modification, add form number to the end of the catalog number. kLA93W required when START/STOP pushbutton remote station is used in conjunction with START/STOP local control OR if local pilot light only is used. kLA94W required when FOR/REV/STOP is required for both local and remote control. kLA95W required when START/STOP pushbutton with pilot light remote station OR pilot light only remote is used with START/STOP pushbutton local control. kLA97W required for remote control only applications. Required when local/remote adapters are used. © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Technical Data Mechanical and Electrical Life Curves Based on Utilization Category and Number of Switching Cycles Alternating Current Utilization Category AC-3 Operating voltage 200 V 230 V 460 V 575 V Operating current at q ≤ 104 °F (40 °C) INTEGRAL 18 18 A 18 A 18 A 18 A INTEGRAL 32 32 A 32 A 32 A 32 A INTEGRAL 63 63 A 63 A 63 A 63 A Rated horsepower at q ≤ 104 °F (40 °C) INTEGRAL 18 5 hp 5 hp 10 hp 15 hp INTEGRAL 32 10 hp 10 hp 20 hp 30 hp INTEGRAL 63 20 hp 20 hp 40 hp 60 hp Electrical life Motor control and protection in utilization categories AC-2, AC-3, AC-4, at Ue ≤ 400 volts Current Breaking Limit 20 INTEGRAL 18 INTEGRAL 32 and 63 Millions of operating cycles Millions of operating cycles 20 4 3 10 8 6 5 4 2 1 2 1.5 2 1.5 1 0.8 0.6 1 0.8 0.6 0.4 0.4 0.2 0.2 0.1 0.08 0.1 0.08 0.06 0.06 0.04 0.04 0.02 0.02 0.01 3 4 5 6 78 10 9 20 18 40 60 100 150 300 80 108 200 Current broken in amperes 01/00 4 (63A) 1 0.01 1 1.5 2 ① ➁ ➂ ➃ a 3 2 1 (32A) 10 8 6 5 4 1 1.5 2 3 4 567 9 8 10 20 32 40 60 80 150 200 300 63 100 192 360 Current broken in amperes Not having previously broken a short circuit current Having broken a short circuit current 10 times at 30 In a Having broken a short circuit current 20 times at 30 In a Having broken a short circuit current 10 times at 100 In Most common value of short circuit current © 2000 Schneider Electric All Rights Reserved 21 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18/32/63 Technical Data Mechanical and Electrical Life Curves Based on Utilization Category and Number of Switching Cycles Electrical life curves CMC size 18 32 63 Wire size (AWG) 12-10 12-8 8-3 600 1200 1200 1200 2400 2400 900 1800 1800 q ≤ 104 °F (40 °C) 18 A 32 A 63 A q ≤ 131 °F (55 °C) 16 A 28 A 55 A q ≤ 158 °F (70 °C) 14 A 25 A 50 A Maximum rate of operating cycles per hour Operating duty 85% - operation at maximum current - operation at 50% of maximum current Operating duty 25% - operation at maximum current Operating current (according to ambient temperature) Electrical Life Utilization category AC-1, Ue ≤ 400 Volts Millions of operating cycles 20 (18 A) (32 A) 10 8 6 5 4 (63 A) 2 1.5 1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04 0.02 0.01 3 4 5 6 7 8 9 10 18 20 32 40 60 63 80 100 Current broken in amperes 22 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18 Technical Data PROTECTON MODULE TRIPPING SPECIFICATIONS Motor Protection By thermal magnetic modules LB1LB03P 300 mn 0.16 0.4 2.5 1 0.25 0.63 1.6 100 0.1 mn 6 4 12 18 10 16 P01 P03 P05 P07 P10 P17 10 mn P02 P04 P06 P08 P13 P21 1mn The average operating times shown are for ambient temperature of 68 °F (20 °C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. 10s 1s 3.75 24 9.45 6 2.4 15 150 240 60 37.5 180 270 90 0.1s 0.01s 0.1 0.2 0.4 0.6 1 2 4 6 10 20 40 60 100 200 400 600 1000 Current in amperes CURRENT LIMITATION AND THERMAL LIMIT ON SHORT CIRCUIT 3-Phase 380/415 V, 50 Hz Current limit on short circuit Thermal limit I2t in kA2s in short circuit protection zone Max. I peak in KA =0 .2 5 100 80 60 12-18 A 10-16 A 60 6-10 A =0 . 3 40 100 80 40 20 .5 4-6 A =0 10 8 6 12-18 A .7 =0 4-6 A 20 2.5-4 A 2 2.5-4 A 10 8 co s ϕ 4 10-16 A 6-10 A 6 1 0.8 0.6 1.6-2.5 A 0.4 1-1.6 A 4 1.6-2.5 A 2 1-1.6 A 0.2 0.63-1 A 0.1 0.1 1 0.2 0.4 0.6 1 2 4 6 8 10 20 50 100 200 1 2 4 Prospective Isc in kA rms 01/00 © 2000 Schneider Electric All Rights Reserved 6 8 10 20 50 100 200 Prospective Isc in kA rms 23 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32 Technical Data Motor Protection Motor Protection (frequent starting) By thermal magnetic modules LB1LC03M By magnetic modules LB6LC03M 300 min 100 min 0.25 0.40 0.63 1 1.6 2.5 4 6.3 10 16 23 25 32 irth M03 M04 M05 M06 10 min 1 min M07 M08 M10 M13 10 s M17 M22 M53 300 min 100 min 10 min 1 min 10 s M06 M08 M07 1s M22 M17 M53 1s 2.4 4.8 7.6 12 19 30 48 76 120 190 3.8 6 9.5 15 24 38 60 95 150 380 9.5 15 300 0.1 s 0.01 s 0.01 s 0.2 0.4 0.6 1 2 4 6 10 20 40 60 100 200 400 600 24 38 19 0.1 s 0.1 M13 M10 0.8 1 2 4 6 10 20 30 60 95 150190 48 76 120 190 300380 40 60 100 200 400 600 1000 The average operating times shown are for ambient temperature of 68 °F (20 °C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. Tripping Curve on Short Circuit Breaking time in ms 90 70 60 50 40 30 20 415 V 10 8 6 5 4 3 2 1 1 2 3 4 5 6 8 10 20 30 40 50 Prospective Isc in kA rms 24 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32 Technical Data CURRENT LIMITATION AND THERMAL LIMIT ON SHORT-CIRCUIT 3-Phase 400/415 V, 50 Hz Current limitation on short-circuit Maximum thermal limit on short-circuit Max. I peak in KA Thermal limit I2t in kA2s in short circuit protection zone 8a 7 6 5 100 80 =0 .2 5 100 80 60 40 =0 .3 60 40 =0 10 8 6 4 8 7a .5 20 6 5 20 =0 .7 3 4 10 8 co sϕ 4 2 3 1 0.8 0.6 2 2 6 4 1 0.4 2 0.2 1 0.1 0.1 0.2 0.4 0.6 1 2 4 6 8 10 15 20 50 100 1 200 2 4 6 8 10 Prospective rms short-circuit current in kA 15 20 50 100 200 Prospective rms short-circuit current in kA 3-Phase 400/415 V, 50 Hz Current limitation on short-circuit Maximum thermal limit on short-circuit Max. I peak in KA Thermal limit I2t in kA2s in short circuit protection zone 100 80 40 60 8a 7 6 5 =0 .3 100 80 60 40 =0 .5 20 6 5 =0 .7 10 8 6 20 4 3 co sϕ 4 3 4 8a 7 2 1 0.8 0.6 3 10 8 2 6 1 4 2 0.4 2 0.2 0.1 0.1 0.2 0.4 0.6 1 2 4 6 8 10 15 20 50 100 200 1 1 2 4 Prospective rms short-circuit current in kA a Associated thermal protection rating. 1 1-1.6 A 5 6.3-10 A 2 1.6-2.5 A 6 10-16 A 3 2.5-4 A 7 16-25 A 4 4-6.3 A 8 23-32 A 01/00 6 8 10 20 50 100 200 Prospective rms short-circuit current in kA For 1-1.6 A ratings, the thermal limit is less than 1x103 A2s The breaking capacity is unlimited on contactor breakers fitted with modules: - up to a rating of 10-16 A at 220/380/415 V. - up to a rating of 6.3-10 A at 440/500 V. © 2000 Schneider Electric All Rights Reserved 25 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 63 Technical Data PROTECTION MODULE TRIPPING SPECIFICATIONS Motor Protection (normal starting duty) By thermal magnetic modules LB1LD03M 300 mn 10 13 18 100 mn 23 28 35 45 63 25 32 40 50 irth M16 M21 M22 M53 M55 M57 M61 10 mn 1mn 10 s 1s 80 110 190 150 480 300 240 380 780 600 0.1s 0.01s 6 40 60 80 100 110 10 15 20 200 400 600 1000 2000 Current in amperes The average operating times shown are for ambient temperature of 68 °F (20 °C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. Tripping Curve on Short Circuit Breaking time in ms 50 40 30 20 415V 10 8 6 5 4 3 2 1 1 2 3 4 5 6 8 10 20 30 40 50 Prospective short-circuit current in kA rms 26 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 63 Technical Data CURRENT LIMITATION AND THERMAL LIMIT ON SHORT-CIRCUIT 3-Phase 400/415 V, 50 Hz Current limitation on short-circuit Maximum thermal limit on short-circuit Maximum peak current in kA Thermal limit I2t in kA2s in short circuit protection zone 100 80 60 25 = 40 1000 800 0. 600 3 = 0. 400 20 5 10 8 6 s 4 3 co ϕ = 1a 0. = a 1 200 7 0. 100 80 2 60 1 0.8 0.6 40 0.4 20 0.2 0.1 10 0.1 0.2 0.4 0.3 1 2 4 6 8 10 15 20 50 100 1 200 2 4 6 8 10 Prospective rms short-circuit current in kA 15 20 50 100 200 Prospective rms short-circuit current in kA 3-Phase 400/415 V, 50 Hz Current limitation on short-circuit Maximum thermal limit on short-circuit Maximum peak current in kA Thermal limit I2t in kA2s in short circuit protection zone 100 80 60 25 = 40 1000 800 0. 3 = 20 5 = 600 0. 0. 400 1a a 1 10 8 6 s 4 3 co ϕ = 200 7 0. 100 2 80 60 1 0.8 0.6 40 0.4 20 0.2 0.1 0.1 0.2 0.4 0.3 1 2 4 6 8 10 15 20 35 50 100 200 10 1 2 4 Prospective rms short-circuit current in kA 1 18-25 A up to 45-63A 01/00 6 8 10 15 20 35 50 100 200 Prospective rms short-circuit current in kA a LB1LD03•22 to LD03•61: rating of associated thermal overload module. © 2000 Schneider Electric All Rights Reserved 27 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Specifications Type Rated operational current (Ie) INTEGRAL 18 Category AC-3 18 A Rated operational voltage (Ue) 600 Vac Breaking capacity at 480 Vac 42 kA RMS Electrical durability in AC-3 at 400 V 2 million operating cycles Mechanical durability at Uc 10 million operating cycles Maximum operating rate at ambient temperature ≤ 131 °F (55 °C) AC control voltage 1200 operating cycles/hour DC control voltage with converter 600 operating cycles/hour Environment Conforming to standards IEC: 364, 947-1, 947-2, 947-4-1, 947-6-2 UTE: NF C 63-110, C 63-120, C 63-130, C 63-650, C 79-100, C 20-040 VDE: 0100, 0110, 0113, 0170, 0171, 471, 0660 EN 60947-1, 60947-2, 60947-4-1, 60947-6-2 NEN, NBN Product approvals ASE, ASEFA, ASTA, CSA, DEMKO, DNV NEMKO, RINA, SEMKO, SETI, UL UL File Number File E164871, CCN NKJH CSA File Number File LR43364 Class 3211 08 Protective treatment Ambient air temperature around the device “TH” Operation -13 to +131 °F (-25 to +55 °C) Storage -40 to +176 °F (-40 to +80 °C) Operation ■ -13 to +122 °F (-25 to +50 °C) Storage -13 to +158 °F (-25 to +70 °C) Vibration resistance Permissible acceleration 5 to 100 Hz Energized state: 3 g De-energized state: 3 g Shock resistance Permissible acceleration Impulse duration: 11 ms Energized state: 8 g De-energized state: 8 g Degree of protection To IEC 144 and 529 To VDE 0106 IP 20B Protection against direct finger contact Flame resistance Conforming to IEC 295-2-1, NF C 20-455, and to decree of 22-12-81 (JO 27 NC of 1st and 2/2/1982) Conforming to UL 94 - V0 and NF T 51-072 Without derating 9,580/3000 ft/m Operating position (without derating) In relation to normal vertical mounting plane From fixing plane (fore-aft tilt) Rated control circuit voltage (Uc) 50 Hz 60 Hz DC with converter 21 to 660 Vac 21 to 600 Vac 24 Vdc Voltage limits at θ ≤ 131 °F (55 °C) Operating Drop out 0.85 to 1.1 Uc 0.25 to 0.7 Uc Average consumption at 68 °F (20 °C) and at Uc AC Inrush Sealed 75 VA (50 Hz), 90 VA (60 Hz) 8 VA (50 Hz), 9 VA(60 Hz) DC ■ Inrush Sealed 100 W 1.5 W 30° 30° From main axis (left-right tilt) ° 90 ° 90 Maximum operating altitude Control Circuit Specifications Heat dissipation Operating time ● at 68 °F (20 °C) and at Uc ■ ● 28 2.5 W (50 Hz), 2.8 W (60 Hz) 50/60 Hz “C” “O” 9 to 25 ms 7 to 25 ms DC with converter “C” “O” 15 to 20 ms 20 to 25 ms With converter. The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time “O” is measure from the moment the coil supply is switched off to the moment the main poles separate. © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Specifications INTEGRAL 32 INTEGRAL 63 32 A 63 A 600 Vac 600 Vac 42 kA RMS 42 kA RMS 1.5 million operating cycles 1.2 million operating cycles 10 million operating cycles 10 million operating cycles 3600 operating cycles/hour 3600 operating cycles/hour 600 operating cycles/hour 600 operating cycles/hour Environment IEC: 364, 947-1, 947-2, 947-4-1, 947-6-2 UTE: NF C 63-110, C 63-120, C 63-130, C 63-650, C 79-100, C 20-040 VDE: 0100, 0110, 0113, 0170, 0171, 471, 0660 EN 60947-1, 60947-2, 60947-4-1, 60947-6-2 NEN, NBN IEC: 364, 947-1, 947-2, 947-4-1, 947-6-2 UTE: NF C 63-110, C 63-120, C 63-130, C 63-650, C 79-100, C 20-040 VDE: 0100, 0110, 0113, 0170, 0171, 471, 0660 EN 60947-1, 60947-2, 60947-4-1, 60947-6-2 NEN, NBN ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, PTB, RINA, SCC, SETI, UL, USSR, LROS ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS pending File E164871, CCN NKJH File E164871, CCN NKJH File LR43364 Class 3211 08 File LR43364 Class 3211 08 “TH” “TH” -13 to +158 °F (-25 to +70 °C) -13 to +158 °F (-25 to +70 °C) -40 to +176 °F (-40 to +80 °C) -40 to +176 °F (-40 to +80 °C) -13 to +122 °F (-25 to +50 °C) -13 to +122 °F (-25 to +50 °C) -13 to +158 °F (-25 to +70 °C) -13 to +158 °F (-25 to +70 °C) Energized state: 3 g De-energized state: 3 g Energized state: 3 g De-energized state: 3 g Energized state: 8 g De-energized state: 8 g Energized state: 8 g De-energized state: 8 g IP 20B Protection against direct finger contact IP 20B Protection against direct finger contact Conforming to IEC 295-2-1, NF C 20-455, and to decree of 22-12-81 (JO 27 NC of 1st and 2/2/1982) Conforming to UL 94 - V0 and NF T 51-072 Conforming to IEC 295-2-1, NF C 20-455, and to decree of 22-12-81 (JO 27 NC of 1st and 2/2/1982) Conforming to UL 94 - V0 and NF T 51-072 9,580/3000 ft/m From fixing plane (fore-aft tilt) From fixing plane (fore-aft tilt) 30° 30° ° 90 ° 90 9,580/3000 ft/m Control Circuit Specifications 24 to 660 Vac 24 to 600 Vac 24, 48, 110 Vdc 24 to 660 Vac 24 to 600 Vac 24, 48, 110 Vdc 0.85 to 1.1 Uc 0.25 to 0.7 Uc 0.85 to 1.1 Uc 0.25 to 0.7 Uc 160 VA (50 Hz), 185 VA (60 Hz) 12 VA (50 or 60 Hz) 375 VA (50 Hz), 450 VA (60 Hz) 25 VA (50 or 60 Hz) 250 W, duration 50 ms 4W 300 W, duration 50 ms 8W 4 W (50 Hz), 5 W (60 Hz) 8 W (50 Hz), 11 W (60 Hz) 9 to 25 ms 7 to 20 ms 12 to 35 ms 7 to 20 ms 25 to 35 ms 10 to 20 ms 25 to 40 ms 15 to 25 ms 01/00 © 2000 Schneider Electric All Rights Reserved 29 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Specifications Type INTEGRAL 18 Pole Specifications θ ≤ 104 °F (40 °C) Rated thermal current (Ith) 18 A Frequency limits of operational current 40-60 Hz Rated impulse withstand voltage To IEC 947.4 Rated insulation voltage (Ui) To IEC 947-1 and NF C 20-040 6 kV in envelope 600 Vac Heat dissipation in the power circuits of the contactor breaker and its protection module Operational current 0.16 A 0.25 A 0.4 A 0.6 A 1.0 A 1.6 A 2.5 A 4.0 A 6.0 A 10.0 A 16.0 A 18.0 A Power per pole, hot state 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.4 W 2.9 W 3.2 W 3.8 W 3.8 W Rated making capacity I RMS To IEC 947-4 and NF C 63-110 15 x Ith (above this value, the breaker trips I Peak To IEC 947-2 and NF C 63-120 Total breaking time 105 kA 2.5 ms Electrical durability in AC-3 at Ie max, Ue = 415 V after 1 P2 cycle (O-t-CO-t-CO) (short-circuit test) Prospective RMS short-circuit current at terminals of a new device 3 kA 10 kA 25 kA 35 kA 42 kA Millions of operating cycles 0.6 0.15 0.12 0.1 0.1 Maximum let-through energy With Isc max, at 415 V, 50 Hz 100 x 103 A2s Wiring Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) AWG Flexible cable without cable end 2 x 6 mm2 2 x 1.5 mm2 2 - #16 to 2 - #10 Flexible cable with cable end 2 x 4 mm2 or 1 x 6 mm2 2 x 1 mm2 2 - #16 to 2 - #10 Solid cable 2 x 6 mm2 2 x 1.5 mm2 2 - #16 to 2 - #10 Tightening torque 12 lb-in (1.7 N•m) Specifications of Thermal-magnetic or Magnetic Only Protection Modules Type LB1LB03P Protection Thermal protection Magnetic protection To IEC 158-1 and NF C 63-650 IEC 947-1/2/4 and NF C 63-120 Standard motors Conforming to standards IEC 947-4 type 2 (Iq = 80 kA except P21) and NF C 63-650 Number of poles 3 Number of protection poles 3 Rated operational voltage 600 Vac Maximum continuous current 0.16 to 18 A Setting range (Irth min/Irth max) 0.1/0.16 to 12/18 A Temperature compensation -4 to +131 °F (-20 to +55 °C) Protection against phase imbalance With Tripping class 10 Instantaneous trip current setting range Fixed at 15 Irth max Tripping tolerance ± 20% Specifications of Versions without Isolator Function Conforming to standards IEC 947 Rated operational voltage 600 Vac Mechanical durability 10,000 operating cycle Padlocking facility 1 padlock, ∅ 5 mm shank Specifications of Versions with Isolator Function Conforming to standards – Rated operational voltage – Mechanical durability – Padlocking facility – 30 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Specifications INTEGRAL 32 INTEGRAL 63 Pole Specifications 32 A 63 A 40-60 Hz 40-60 Hz 6 kV in envelope 6 kV in envelope 600 Vac 600 Vac 1.6 A 2.5 A 4.0 A 6.3 A 10.0 A 16.0 A 25.0 A 32.0 A 25 A 32 A 40 A 50 A 63 A 1.6 W 1.8 W 1.8 W 2.0 W 2.0 W 3.4 W 4.8 W 6.0 W 4.4 W 5.0 W 5.8 W 7.0 W 9.0 W 12 x Ith (above this value, the breaker trips 12 or 15 x Ith (above this value, the breaker trips 105 kA 105 kA 4 ms 4 ms 3 kA 10 kA 25 kA 35 kA 42 kA 3 kA 10 kA 25 kA 35 kA 42 kA 1 0.9 0.6 0.5 0.2 1 0.9 0.6 0.5 0.2 170 x 103 A2s 300 x 103 A2s Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) AWG Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) AWG 1 X 10 or 2 x 6 mm2 1 x 1 mm2 #18 to #8 1 X 50 or 2 x 35 mm2 1 x 6 mm2 #10 to #2 1 x 6 or 2 x 4 mm2 1 x 1 mm2 #18 to #8 2 x 25 mm2 1 x 6 mm2 #10 to #2 1 x 10 or 2 x 6 mm2 1 x 1 mm2 #18 to #8 1 x 50 mm2 1 x 6 mm2 #10 to #2 14 lb-in (2.0 N•m) 42 lb-in (6.0 N•m) Specifications of Thermal-magnetic or Magnetic Only Protection Modules LB1LC03M LB6LC03M LB1LD03M LB6LD03M Standard motors Frequent starting motors Standard motors Frequent starting motors IEC 947-4 type 2 (Iq = 50 kA) and NF C 63-650 NF C 63-650 NF C 63-650 NF C 63-650 3 3 3 3 3 3 3 3 600 Vac 600 Vac 600 Vac 600 Vac 0.4 to 32 A 0.4 to 32 A 13 to 63 13 to 63 0.25/0.4 to 23/32 A – 10/13 to 45/63 A – -4 to +158 °F (-20 to +70 °C) -4 to +158 °F (-20 to +70 °C) -4 to +158 °F (-20 to +70 °C) -4 to +158 °F (-20 to +70 °C) With Without With Without 10 – 20 – 6 to 12 Irth max (Usual setting 9 to 10 Irth max) 6 to 12 Irth max 6 to 12 Irth max (Usual setting 9 to 10 Irth max) 6 to 12 Irth max ± 20% ± 20% ± 20% ± 20% Specifications of Versions without Isolator Function IEC 947 IEC 947 600 Vac 600 Vac 10,000 operating cycles 10,000 operating cycle 1, 2, or 3 padlocks, ∅ 8 mm shank 1, 2, or 3 padlocks, ∅ 8 mm shank Specifications of Versions with Isolator Function IEC 947, NF C 63-130, VDE 0660, VDE 0113 IEC 947, NF C 63-130, VDE 0660, VDE 0113 600 Vac 600 Vac 10,000 operating cycles 10,000 operating cycles 1, 2, or 3 padlocks (shank ∅ 8 mm max and ∅ 5 mm min). When flush mounting, interlocking of the enclosure or cabinet door is possible. 1, 2, or 3 padlocks (shank ∅ 8 mm max and ∅ 5 mm min). When flush mounting, interlocking of the enclosure or cabinet door is possible. 01/00 © 2000 Schneider Electric All Rights Reserved 31 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Instantaneous Auxiliary Contacts Rated thermal current (Ith) 10 A (INTEGRAL 18), 6 A (INTEGRAL 32 and 63) Rated insulation voltage (Ui) To IEC 947-1 and NF C 20-040 690 Vac Switching capacity With U ≥ 17 V and I ≥ 10 mA 600 mVA Voltage 48 Vac 110/120 Vac 220/240 Vac 380/400 Vac 480 Vac 1 million operating cycles 300 VA 500 VA 600 VA 520 VA 500 VA AC category AC-15 c Rated operational power Making capacity DC category DC-13 q Rated operational power Making capacity 1.5 million operating cycles 160 VA 300 VA 330 VA 300 VA 280 VA AC category AC-15 1500 VA 3500 VA 6000 VA 7500 VA 7000 VA Voltage 24 Vac 48 Vac 110 Vac 220 Vac 440 Vac 1 million operating cycles 120 W 90 W 75 W 68 W 61 W 1.5 million operating cycles 70 W 50 W 38 W 33 W 28 W DC category DC-13 800 W 700 W 400 W 260 W 220 W Maximum c.s.a.: 2 x 2.5 mm2. Minimum c.s.a.: 2 x 1 mm2 Wire size Maximum: 2 x 14 AWG, Minimum: 2 x 16 AWG c q Electrical durability on an inductive load such as the coil of an electromagnet: making capacity (cosϕ 0.7) = 10 times the breaking capacity (cos ϕ 0.4). Electrical durability on an inductive load such as the coil of an electromagnet, the time constant increasing with the power. Signalling Contacts Rated thermal current (Ith) 6 A (INTEGRAL 18), 3 A (INTEGRAL 32 and 63) Rated insulation voltage (Ui) To IEC 947-1 690 Vac (INTEGRAL 18), 250 Vac (INTEGRAL 32 and 63) Operational power for 200 000 operating cycles AC Voltage – – 110/127 Vac Resistive load – – 600 VA 750 VA Lamp load k – – 90 VA 125 VA 220 Vac Inductive load f – – 875 VA 500 VA Motor p – – 160 VA 200 VA DC Voltage 24 Vac 48 Vac 110/125 Vac 200 Vac Resistive load 100 W 100 W 50 W 50 W Lamp load k 50 W 50 W 6W 7.5 W Inductive load f 75 W 75 W 50 W 50 W Motor p 75 W 75 W 6W 7.5 W Maximum c.s.a.: 2 x 2.5 mm2. Minimum c.s.a.: 2 x 1 mm2 Wire size Maximum: 2 x 14 AWG, Minimum: 2 x 16 AWG k f p Lamp load: peak current = 10 times the rated current. Inductive load: cos ϕ 0.4 for AC operation; time constant 7 ms for DC operation. Motor: peak current = 6 times the rated current. Isolating Auxiliary Contacts for INTEGRAL 32 and 63 Rated thermal current (Ith) Rated insulation voltage (Ui) to IEC 947 and NF C 63-130 6A AC supply DC supply 690 Vac 125 Vac Maximum c.s.a.: 2 x 1.5 or 1 x 2.5 mm2 Wire size Maximum: 2 x 16 AWG or 1 x 14 AWG 32 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Environment Type LA4DT (On-delay) LA4DR (Off-delay) Conforming to standards IEC 255-5 IEC 255-5 Product approvals Pending UL, CSA UL, CSA “TH” “TH” To VDE 0106 Against direct finger contact Against direct finger contact Storage -40 to +176 °F (-40 to +80 °C) -40 to +176 °F (-40 to +80 °C) Operation -13 to +131 °F (-25 to +55 °C) -13 to +131 °F (-25 to +55 °C) Operation at Uc -13 to +158 °F (-25 to +70 °C) -13 to +158 °F (-25 to +70 °C) To IEC 947-1 and VDE 0110 (group C) 250 Vac 250 Vac 0.1-2/1.5-0/25-500 sec. 0.1-2/1.5-30/25-500 sec. Protective treatment Degree of protection Ambient air temperature around the device Rated insulation voltage (Ui) Time Delay Specifications Timing ranges Repeat accuracy 32-104 °F (0-40 °C) ± 3% (10 ms minimum) ± 3% (10 ms minimum) During the time delay 100 ms 225 ms After the time delay 50 ms – During the time delay 10 ms 20 ms After the time delay 2 ms – – 40 ms By LED Illuminates during time delay Illuminates during time delay On input By varistor By varistor Contactor breaker coil suppression By varistor By peak limiting diode Rated control circuit voltage (Uc) 24-250 Vac or Vdc 24-250 Vac Voltage limits 0.8-1.1 Uc 0.8-1.1 Uc By mechanical contact only By mechanical contact only (connecting cable < 10 m) Minimum c.s.a.: 1 x 1 mm2 Maximum c.s.a.: 2 x 2.5 mm2 Minimum c.s.a.: 1 x 1 mm2 Maximum c.s.a.: 2 x 2.5 mm2 Minimum: 1 x 16 AWG Maximum: 2 x 14 AWG Minimum: 1 x 16 AWG Maximum: 2 x 14 AWG Maximum power dissipated 2W 3.5 W Leakage current < 5 mA < 5 mA Residual voltage 3.3 Vac 3.3 V Overvoltage protection 3 kV; 0.5 joule 3 kV; 0.5 joule Electrical durability 30 million operating cycles 30 million operating cycles Reset time Immunity to micro-breaks Minimum control pulse duration Time delay signalling Control Circuit Specifications Built-in protection Control type Flexible or solid cable with or without cable end Wire Size Switching Specifications (solid state type) Operating diagrams Electronic on-delay timer LA4DT Uc supply (A1 - A2) Time delay output Contactor breaker coil Electronic off-delay timer LA4DR Uc supply (A1 - A2) 1 0 1 0 Control (A2 - B2) 1 0 1 0 Time delay output Contactor breaker coil 1 0 t Red LED 01/00 ≤ 40 ms t Red LED © 2000 Schneider Electric All Rights Reserved 33 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Type Used for direct control of the INTEGRAL 18 Interface modules Converters By a programmable controller, with AC control of the coil By a programmable controller, with DC control of the coil. Protective treatment “TH” “TH” Ambient air temperature around the device Storage: -104 to + 176 °F (- 40 to+ 80 °C) Storage: -104 to + 176 °F (- 40 to + 80 °C) Operation: -13 to +131 °F (-25 to +55 °C) Operation: -13 to +122 °F (-25 to +50 °C) Rated insulation voltage (Ui) 250 Vac to IEC 158-1 and 947-1 and VDE 0110 (group C) – Protection against direct finger contact Conforming to VDE 0106 Conforming to VDE 0106 Max: 2 x 2.5 mm2, Min: 1 x 1 mm2 Max: 2 x 2.5 mm2, Min: 1 x 1 mm2 Cabling Max: 2 x 14 AWG, Min: 1 x 16 AWG Max: 2 x 14 AWG, Min: 1 x 16 AWG Operating limits – 0.8 to1.1 Uc q Protection Of the input and against reverse polarity: by diode Against reverse polarity (by diode) and against overvoltage Control Circuit Specifications LA4DLB LA4DLE LA4DWB LA1LB080BD Solid state Solid state A2 c E2 – E1 + A1 c A2 c E2 – E1 + A1 c Relay + override A2 c LA4DFE E2 – Relay E1 + LA4DFB Technology A1 c Type Indication of input state K (0V) A1 E3 E2 A2 A2 A1 K A2 A1 A2 A1 – K E1 + Wiring Schematics By built-in LED Input signals (logic side) Voltage 24 Vdc (E1-E2) 48 Vdc 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc (E2-E3) Current 15 mA 25 mA 15 mA 8.5 for 5 V 15 for 24 V 10 25 mA State “0” guaranteed for U < 2.4 Vac or I < 2 Vac < 4.8 Vac < 2.4 Vac < 4.8 Vac < 2.4 Vac < 7 Vac < 1.3 Vac < 2 Vac < 1.3 Vac < 2 Vac < 5 Vac State “1” guaranteed for U 33 < U < 60 Vac 17 < U < 30 Vac 33 < U < 60 Vac 5 < U < 30 Supply voltage 17 < U < 30 Vac 24-250 Vac (A1-A2) U > 14 24 Vdc (E1-E2) q Operating Specifications Electrical durability in 10 million operating cycles 10 million operating cycles 3 million operating cycles 3 million operating cycles 20 million operating cycles 2 million operating cycles Immunity to control circuit interruptions 4 ms 4 ms 4 ms 4 ms 1 ms – Average consumption at 86 °F (30 °C) 0.6 W 0.6 W 0.6 W 0.6 W 0.4 W Inrush: 100 Sealed: 1.5 Pull-in 15-30 ms 15-30 ms 15-30 ms 15-30 ms – 30 ms Drop-out 20-35 ms 20-35 ms 20-35 ms 20-35 ms – 15 ms Operating time c at 86 °F (30 °C) and at Uc c q 34 The operating times depend on the type of electromagnet driving the contactor breaker and its control method. The closing time “C” is measured from the moment the INTEGRAL coil supply is switched on to initial contact of the main poles. The opening time “O” is measured from the moment the coil supply is switched off to the moment the main poles separate. Warning: for supply from rectified AC, the power supply must exceed 150 VA and the maximum ripple must be ≤ 14%. © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Type Interface modules Converters Used for direct control of the INTEGRAL 32 or 63 By a programmable controller, with AC control of the electromagnet By a programmable controller, with DC control of the coil Storage: -13 to +158 °F (- 25 to + 70 °C) Storage: -13 to +158 °F (- 25 to + 70 °C) Operation: -13 to +122 °F (- 25 to+ 50 °C) Operation: -13 to +122 °F (- 25 to + 50 °C) Ambient air temperature around the device Insulation rms voltage between inputs and outputs: 2.5 kV Common negative terminals Max: 2 x 2.5 mm2, Min: 1 x 1 mm2 Max: 2 x 2.5 mm2, Min: 1 x 1 mm2 Wiring Max: 2 x 14 AWG, Min: 1 x 16 AWG Max: 2 x 14 AWG, Min: 1 x 16 AWG Operating limits 0.85-1.1 Uc 0.8-1.1 Uc q Protection Against reverse polarity (by diode) and against overvoltage Against reverse polarity (by diode) and against overvoltage Indication of input state By LED – Type INTEGRAL 32 INTEGRAL 63 INTEGRAL 32 INTEGRAL 63 LA1LC LA1LD LA1LC LA1LD 580BD 580ED 180BD LA1L•580•D 180BD A1 + E1 – E2 080BD – c A2 A2 080FD A2 080BD 080ED 080FD LA1L•080FD E1 + – E2 c A2 080ED LA1L•080BD LA1L•080ED c A1 A1 + E1 Input signals (logic side) 580ED LA1L•180BD c A1 Wiring Schematics 580BD E1 + A1 (0V) E3 E2 – A2 A1 (0V) A2 E2 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc c 48 Vdc c 24 Vdc c 48 Vdc – (E1-E2) (E1-E2) (E1- E2) (E1-E2) (E1-E2) (E1-E2) (E3-E2) (E3-E2) – (E3-E2) (E3-E2) – 20 mA 8.5 at 5V 15 at 24V 25 mA 8.5 at 5V 15 at 24V 20 mA 10 mA – 20 mA 10 mA – 30 mA State “0” guaranteed for U < 2.4 Vac I < 2 mA State “1” guaranteed for U > 20.4 Vac 50 mA < 4.8 Vac < 2.5 Vac < 2.4 Vac < 4.8 Vac < 2.5 Vac < 7 Vac < 14 Vac – < 7 Vac < 14 Vac – < 2 mA < 2 mA < 2 mA < 2 mA < 2 mA < 5 mA < 2.5 mA – < 5 mA < 2.5 mA – > 40.8 Vac > 4 Vac > 20.4 Vac > 40.8 Vac > 4 Vac > 14 Vac > 28 Vac – > 14 Vac > 28 Vac – 24-240 Vac 24-240 Vac 24-240 Vac 24-240 Vac 24-240 Vac 24-240 Vac 24 Vdc q 48 Vdc q 110 Vdc q 24 Vdc q 48 Vdc q 110 Vdc q (A1-A2) (E1-E2) (E1-E2) (E1-E2) (E1-E2) (E1-E2) Supply voltage Electrical durability in millions of operating cycles Average consumption (A1-A2) (A1-A2) (A1-A2) (E1-E2) 1 Inrush 50 Hz 160 VA 160 VA 160 VA 375 VA 375 VA 375 VA – – – – – – 60 Hz 185 VA 185 VA 185 VA 450 VA 450 VA 450 VA – – – – – – – – – – – 250 W 250 W 250 W 300 W 300 W 300 W 12 VA 12 VA 25 VA 25 VA 25 VA – – – – – – – – – – – 4W 4W 4W 8W 8W 8W Pull-in 15-30 ms 15-30 ms 10-35 ms 20-40 ms 20-40 ms 10-45 ms 30 ms 30 ms 30 ms 35 ms 35 ms 35 ms Drop-out 22-35 ms 22-35 ms 8-30 ms 25-45 ms 25-45 ms 8-30 ms 15 ms 15 ms 15 ms 20 ms 20 ms 20 ms DC – DC – c q (A1-A2) 5 Sealed 50/60 Hz 12 VA Operating time at 68 °F (20 °C) and at Uc (A1-A2) For direct control by external contact: connect E1-E3. Warning: for supply from rectified a.c., the power supply must exceed 250 VA (300 VA for INTEGRAL 63) and the maximum ripple must be ≤ 14%. 01/00 © 2000 Schneider Electric All Rights Reserved 35 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Environment — Control and Suppressor Modules Conforming to standards IEC 337-1 Protective treatment Ambient air temperature around the device “TH” Storage -104 to + 176 °F (- 40 to + 80 °C) Operation -13 to + 131 °F (- 25 to + 55 °C) Permissible for operation at Uc -13 to + 158 °F (- 25 to + 70 °C) Protection against direct finger contact Conforming to VDE 0106 Control modules “Automatic-Manual-Stop” LA4DM for INTEGRAL 18 Application The “Automatic-Manual” selector switch must be operated with the “Start-Stop” switch in the “Stop” position Indication By LED incorporated in the unit; illuminated when the contactor breaker coil is energized Protection Against electrical shocks Built-in protection Contactor coil suppression Electrical life Contact block specifications 2 kV By varistor 20,000 operating cycles Rated insulation voltage (Ui) Rated operational voltage (Ue) 250 Vac conforming to IEC 158-1 and VDE 0110 group C 250 Vac Maximum c.s.a.: 2 x 2.5 mm2, Minimum c.s.a.: 1 x 1 mm2 Wire Size Maximum: 2 x 14 AWG, Minimum: 1 x 16 AWG Suppressor modules LA4DA, DE for INTEGRAL 18 Type LA4DA2• LA4DE2• Type of protection RC (Resistor-capacitor) Varistor Wiring Schematics Rated operational voltage (Ue) 50/60 Hz Maximum peak voltage 24-250 Vac 24-250 Vac 3 Uc 2 Uc 24/48 Vac 50/127 Vac 110/240 Vac – 400 Hz 200 Hz 100 Hz – Natural RC frequency Insulation voltage Conforming to IEC 158-1 and VDE 0110 group C 250 Vac 250 Vac Suppressor module LA9-D09982 for INTEGRAL 18, 32 and 63 Type of protection RC (Resistor-Capacitor) Wiring Schematic Operational voltage 36 ≤ 250 Vac © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Specifications Environment — Tripping and Reset Devices Conforming to standards Protective treatment Ambient air temperature around the device Storage -40 to +176 °F (-40 to +80 °C) Operation -13 to +131 °F (-25 to +55 °C) Permissible for operation at Uc Protection against direct finger contact -13 to +158 °F (-25 to +70 °C) Conforming to VDE 0106 Tripping devices Type LA1LC070•, LC072• LA1LC071• Pull-in voltage 0.8-1.1 Uc 0.7-1.1 Uc 0.35-0.7 Uc – Drop-out voltage Inrush 8 VA 8 VA Sealed 4 VA 4 VA – 10 ms Average consumption Minimum impulse duration Reset devices Type LA1LC052• Consumption 9 VA Duration of a reset cycle 9 sec Minimum impulse duration 0.5 sec 01/00 © 2000 Schneider Electric All Rights Reserved 37 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18 Auxiliary Contact States Non-Reversing INTEGRAL 18 Auxiliary contact actuators LD1 A1 0 AUTO + 0 AUTO + 0 AUTO + 0 5/L3 3/L2 + A2 1/L1 AUTO Auxiliary contacts LA1LB017 LA1LB019 LA1 LA1 LA1 LB001 LB031 LB0311 LA1LB034 LA1LB0341 31 97 13 31 95 41 15 17 17 15 15 17 05 07 17 15 32 98 14 32 96 42 16 18 18 16 16 18 06 08 18 16 05 13 14 07 97 13 31 08 95 96 98 97 06 13 23 31 14 24 32 6/T3 4/T2 2/T1 LA1LB015 contact open contact closed Off 13 23 31 95 97 13 31 95 41 15 17 17 15 15 17 05 07 17 15 05 07 14 24 32 96 98 14 32 98 14 32 96 42 16 18 18 16 16 18 06 08 18 16 06 08 On, contactor open 15 17 17 15 15 17 17 15 16 18 18 16 16 18 18 16 AUTO On, contactor closed AUTO 13 23 31 13 31 13 31 41 14 24 32 14 32 14 32 42 Tripped on overload 13 23 31 95 97 13 31 97 13 31 95 41 15 17 17 15 15 17 17 15 14 24 32 96 98 14 32 98 14 32 96 42 16 18 18 16 16 18 18 16 TRIP. + Tripped on short-circuit TRIP. + 05 07 05 07 06 08 06 08 05 07 05 07 06 08 06 08 Off after short-circuit TRIP. + 95 97 97 95 96 98 98 96 Manual reset TRIP. + RESET 38 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 18 Auxiliary Contact States Reversing INTEGRAL 18 Auxiliary contact actuators A1 A2 + 0 AUTO + 0 A2 5/L3 AUTO A1 3/L2 1/L1 LD1 Auxiliary contacts II I LA1 LB001 97 13 31 97 13 31 95 41 13 23 31 15 17 13 23 31 17 15 41 05 07 14 32 98 14 32 96 42 14 24 32 16 18 14 24 32 18 16 42 06 08 On the LA1 LB001 INTEGRAL 95 LA1LB0211 96 LA1LB021 98 LA1LB019 13 23 31 LA1LB017 14 24 32 4/T2 2/T1 6/T3 LA1LB015 13 23 31 15 17 13 23 31 17 15 41 05 07 contact open contact closed Off 13 23 31 95 97 13 31 14 24 32 96 98 14 32 97 13 31 95 41 98 14 32 96 42 14 24 32 16 18 14 24 32 18 16 42 06 08 On, contactors open AUTO 15 17 17 15 16 18 18 16 On, closed AUTO 13 23 31 13 31 13 31 41 14 24 32 14 32 14 32 42 On, closed AUTO 13 23 31 13 31 13 31 41 13 23 31 13 23 31 41 14 24 32 14 32 14 32 42 14 24 32 14 24 32 42 Tripped on overload TRIP. + 95 97 97 95 13 23 31 15 17 13 23 31 17 15 41 96 98 98 96 14 24 32 16 18 14 24 32 18 16 42 Tripped on short-circuit 05 07 TRIP. + 06 08 Off after short-circuit TRIP. + 95 97 97 95 96 98 98 96 Manual reset 05 07 TRIP. + 06 08 RESET 01/00 © 2000 Schneider Electric All Rights Reserved 39 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32 and 63 Auxiliary Contact States Non-Reversing INTEGRAL 32 and 63 1/L1 5/L3 3/L2 5/L3 3/L2 LD4 1/L1 LD1 Auxiliary contact actuators A1 + 0 A2 A2 A1 AUTO U U U Auxiliary contacts LA1LC012 LA1 LA1 LA1 LC001 LC020 LC030 LA1LC025 98 41 13 23 31 (53) 63 95 42 14 24 32 (54) 64 96 13 23 31 98 08 13 23 31 96 98 06 08 16 18 13 23 31 6/T3 4/T2 2/T1 6/T3 41 13 23 31 14 24 32 06 08 96 98 13 23 31 08 98 13 23 31 96 98 53 15 05 95 14 24 32 05 95 14 24 32 95 95 42 14 24 32 54 05 16 18 14 24 32 14 24 32 13 23 31 14 24 32 95 95 05 95 or contact open contact closed 15 4/T2 2/T1 LA1LC010 LD4 LD1 Off + isolation Off 53 54 On, contactor open AUTO 16 18 AUTO 15 On, contactor closed AUTO AUTO 13 23 31 13 23 31 13 23 31 41 13 23 31 14 24 32 14 24 32 14 24 32 42 14 24 32 Tripped on overload TRIP. + TRIP. + 13 23 31 16 18 96 98 13 23 31 98 13 23 31 96 98 41 13 23 31 14 24 32 15 95 14 24 32 95 14 24 32 95 95 42 14 24 32 Off after overload TRIP. + TRIP. + 96 98 98 96 98 95 95 95 95 Tripped on short-circuit TRIP. + TRIP. + 06 08 96 98 08 98 96 98 05 95 05 95 95 95 96 98 98 96 98 95 95 95 95 Off after short-circuit TRIP. + TRIP. + Manual reset TRIP. + RESET 40 TRIP. + 06 08 08 05 05 RESET © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers INTEGRAL 32 and 63 Auxiliary Contact States Reversing INTEGRAL 32 and 63 Auxiliary contact actuators 5/L3 3/L2 1/L1 LD5 + 0 or U A1 A2 A2 A1 AUTO U U Auxiliary contacts 41 13 23 31 95 14 24 32 42 14 24 32 96 98 13 23 31 41 13 23 31 53 63 14 24 32 15 05 95 14 24 32 05 95 14 24 32 95 95 14 24 32 42 14 24 32 54 64 98 08 98 13 23 31 14 24 32 13 23 31 96 95 98 13 23 31 05 08 13 23 31 13 23 31 96 96 98 06 06 08 16 16 18 18 13 23 31 13 23 31 14 24 32 53 63 LA1 LA1 LA1 LA1 LC020 LC001 LC021 LC031 95 98 LA1LC025 05 08 LA1LC012 54 64 95 or 15 contact open contact closed Off + isolation 14 24 32 6/T3 4/T2 2/T1 LA1LC010 Off 53 63 54 64 On, reversing contactor open AUTO 16 18 15 On, closed AUTO 41 13 23 31 42 14 24 32 On, closed AUTO Tripped on overload TRIP. + 13 23 31 13 23 31 13 23 31 13 23 31 41 13 23 31 14 24 32 14 24 32 14 24 32 14 24 32 42 14 24 32 13 23 31 16 18 96 98 13 23 31 98 13 23 31 96 98 13 23 31 41 14 24 32 15 95 14 24 32 95 14 24 32 95 95 14 24 32 42 Off after overload TRIP. + 96 98 98 96 98 95 95 95 95 Tripped on short-circuit TRIP. + 06 08 96 98 08 98 96 98 05 95 05 95 95 95 96 98 98 96 98 95 95 95 95 Off after short-circuit TRIP. + Manual reset TRIP. + 06 08 08 05 05 RESET 01/00 © 2000 Schneider Electric All Rights Reserved 41 INTEGRAL™ Self-Protected Combination Motor Controllers Wiring Diagrams The symbols below are used to show the operation of the INTEGRAL CMC and its overload module and auxiliary blocks. Most are taken directly from IEC Standard symbology, but since the INTEGRAL CMC is a unique product, some of the symbols are unique to the device. Contactor Coil I II Left contactor coil on a reversing INTEGRAL CMC Right contactor coil on a reversing INTEGRAL CMC Normally open contact Normally closed contact “Magnetic-Level” trip – an occurrence of >15 times the dial current setting “Thermal-Level” trip – a trip caused by an overcurrent of 105% to 1500% of the dial current setting A trip caused by either thermal or magnetic level fault U Undervoltage trip – when used with an LA1LC070 or LA1LC072 Shunt trip – when used with an LA1LC071 Auxiliary contact that activates when device trips due to: magnetic-level or thermal-level overcurrent, undervoltage, or shunt trip. U Isolator contact on INTEGRAL 32 and INTEGRAL 63 INTEGRAL contactor/circuit breaker contact set 42 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Wiring Diagrams Handle Operator A2 A2 A1 5/L3 A1 5/L3 3/L2 1/L1 A2 A1 Coil Control Circuit 3/L2 INTEGRAL 18 Reversing CMC with protection module LB• LD5LB130 + LB1LB03P 1/L1 INTEGRAL 18 Non-Reversing CMC with protection module LB• LD1LB030 + LB1LB03P II Control Circuit Contact I Electrical Interlock Contact Protection Module Thermal Trip Trip Mechanism Add-on blocks For LD1 Mounted on LH side 31 41 42 LA1LB001 32 13 14 31 13 14 32 31 23 24 32 13 95 97 98 96 97 98 Control knob position 95 18 16 LA1LB019 Trip signalling 96 17 15 Auto 0 14 07 18 LA1LB017 LA1LB015 Short-circuit Signalling Signalling 16 4/T2 Breaker 08 17 05 15 06 For LD1 and LD5 Mounted on RH side LA1LB031 LA1LB034 2/T1 6/T3 6/T3 4/T2 2/T1 Magnetic Trip For LD5 Mounted on LH side Breaker LA1LB0311 31 07 08 Auto 0 Contacts incorporated in unit 05 32 23 24 14 13 LA1LB021 06 17 42 Short-circuit signalling 41 LA1LB001 15 07 08 17 05 15 06 LA1LB0341 Short-circuit signalling 15 17 18 Control knob position 16 18 16 18 Auto 0 Signalling Control knob position Breaker 05 07 08 Contacts incorporated in unit 06 23 31 32 17 18 24 15 14 13 LA1LB0211 16 41 LA1LB001 42 16 Signalling Short-circuit signalling Auto 0 Signalling 01/00 © 2000 Schneider Electric All Rights Reserved Control knob position 43 INTEGRAL™ Self-Protected Combination Motor Controllers Wiring Diagrams 3/L2 5/L3 4/T2 6/T3 4/T2 6/T3 A2 A1 1/L1 2/T1 6/T3 For LD1 or LD4 and LD5 Mounted on RH side Isolator Breaker 41 42 31 32 96 31 32 ou 95 23 24 23 13 14 24 31 32 13 23 24 08 05 14 13 14 98 31 32 98 23 96 24 08 06 16 +0 ou 15 Auto LA1LC001 18 Short-circuit signalling 05 95 Trip signalling 98 14 13 (64) (63) 54 53 1 or 2 LA1LC030 LA1LC025 LA1LC020 95 LA1LC012 LA1LC010 95 LA1LC030 53 4/T2 LB6LC03M 2/T1 Add-on blocks For LD4 Mounted on LH side 2/T1 5/L3 6/T3 A2 LB6LC03M 54 A1 3/L2 4/T2 A2 1/L1 5/L3 6/T3 2/T1 3/L2 4/T2 INTEGRAL 32 Reversing CMC with protection module LB• LD5LC•30 + LB1LC03M LD4LC••0 + LB1LC0•• A1 1/L1 2/T1 A2 A1 INTEGRAL 32 Non-Reversing CMC with protection module LB• LD1LC0•0 + LB1LC0•• Control knob position signalling For LD5 Mounted on LH side 23 24 31 13 14 63 64 32 41 53 54 LA1LC031 44 LA1LC021 42 LA1LC001 Isolator © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Wiring Diagrams 3/L2 5/L3 4/T2 6/T3 6/T3 A2 A2 A1 1/L1 2/T1 5/L3 6/T3 A2 A1 –Q1 4/T2 3/L2 4/T2 A1 1/L1 2/T1 5/L3 3/L2 INTEGRAL 63 Reversing CMC with protection module LB• LD5LD•30 + LB1LD03M OR LD03P LD4LD•30 + LB1LD03• A2 A1 1/L1 INTEGRAL 63 Non-Reversing CMC with protection module LB• LD1LD030 + LB1LD03• 6/T3 4/T2 2/T1 –Q1 2/T1 6/T3 Add-on blocks For LD4 Mounted on LH side For LD1 or LD4 and LD5 Mounted on RH side Isolator Breaker 31 41 32 42 96 ou 95 31 32 23 23 24 24 13 14 13 31 32 14 23 24 98 13 14 08 05 ou 95 31 32 08 LA1LC001 15 18 +0 16 Auto 06 Short-circuit signalling 05 95 Trip signalling 98 23 96 1 or 2 LA1LC030 LA1LC025 LA1LC020 24 14 13 (64) (63) 54 53 53 54 LA1LC012 LA1LC010 95 LA1LC030 98 4/T2 LB6LD03M 2/T1 LB6LD03M Control knob position signalling For LD5 Mounted on LH side 23 24 31 13 14 63 64 32 41 53 54 LA1LC031 01/00 LA1LC021 42 LA1LC001 Isolator © 2000 Schneider Electric All Rights Reserved 45 INTEGRAL™ Self-Protected Combination Motor Controllers Wiring Diagrams Tripping devices ■ for LD1, LD4, LD5 LA1LC070, LC072 Auto C1 D1 LA1LC071 Remote electrical reset devices ■ for LD1, LD4, LD5 LA1LC052• TRIP + RESET U< c C2 D2 c B4 M B2 B3 ■ B1 The use of instantaneous auxiliary contact block LA1LC020 prevents the use of tripping devices or electrical reset devices. For INTEGRAL self-protected CMCs already fitted with an LA1LC010 or LA1LC012 instantaneous auxiliary contact block. Interface modules LA1LC180, LD180 A2 c A2 E2 – A1 c A1 E1 + A2 c E2 – K LA4DL relay output (with manual override) A2 K E1 + A1 A2 c A1 c LA4DF relay output A2 E2 – E1 + A1 A1 c Interface modules LA4DW solid state K LA1LC580, LD580 c A1 c A1 A1 A1 + E1 + E1 – E2 – E2 c A2 c A2 A2 A2 Voltage converters LA1LB080, LC080, LD080 (supplied with devices for DC operation) + E1 a Supply E3 c E2 c – Low level input (0V) A1 + – c E2 (1) A2 c a AUTO/ MAN t 0 a E3 Control modules Automatic-Manual-Stop LA4DM• LA4DR Off-delay t 0 A2 A2 c a A2 A1 Electronic serial timer modules LA4DT On-delay – (0V) B2 c E2 A2 A1 – (0V) E1 + A1 A2 A1 Switching by “low level” input 24 or 48 V B1 a E1 + Switching by control contact 110 V A1 Switching by control contact 24 or 48 V 46 © 2000 Schneider Electric All Rights Reserved K A2 A1 K A2 A1 K A2 A1 I/O 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Dimensions 3.54 90 INTEGRAL 18 Mounting on 35 mm DIN rail 3.95 100.5 7.64 194 4xM5 6.32 160.5 2.32 59 0.27 6.8 1.77 45 5.31 5.31 135 135 0.27= 6.8 3.50 89 7.40 188 DC control circuit LD•LD030 + LB•LD030M•• + LA1D080 1.77 5.20 129.5 45 8.27 210 6.04 153.5 4.78 121.5 10.8 275 1.77 3.84 97.5 45 8.27 210 5.83 148 4xM5 2.48 2.32 63 59 7.13 181 INTEGRAL 32 Mounting on 35 mm DIN rail Dual Dimensions inches mm 1.77 45 LA1LD080 5.75 146 0.65 16.5 = 0.65 16.5 = 3.9 99 3.9 100 3.46 88 4.29 109 4.84 123 6.1 155 4xM4 9.8 250 5.2 132 3.95 100.5 9.57 243 4.78 121.5 4.78 121.5 7.56 192 1.10 28 6.24 158.5 1.77 45 = = 1.3 33 5.06 128.5 2.60 66 3.34 85 36 1.59 40.5 4.78 121.5 = 4xM4 1.77 45 LA1LC080 INTEGRAL 63 Non-Reversing and Reversing AC control circuit Non-reversing, LD•LD030 + LB•LD03M•• Reversing, LD5LD•30 + LB•LD03M•• 5.75 146 6.59 167.5 3.84 97.5 2.7 70 0.31 8 = 1.41 1.77 45 DC control circuit LD•LC030 + LB•LC030M•• + LA1LC080 2.67 1.17 2.67. 68.5 45 68.5 6.30 160 7.17 182 3.50 89 = 0.17 .17 4.5 4.5 4.31 4.8109.5 123 5.47 139 LD5LC030 + LB•LC03M•• 2.69 1.77 2.69 68.5 45 68.5 6.30 160 3.66 93 3.70 94 0.74 19 4.29 109 4.84 123 6.1 155 2xøM4 2 x ØM4 = 1.77 45 INTEGRAL 32 Non-Reversing and Reversing AC control circuit LD•LC030 Common side view + LB•LC03M•• 3.46 88 1.77 45 3.5 90 3.9 99 0.17 4.5 0.31 8 1.77 45 1.59 40.5 LA1LB080 5.31 135 5.31 135 0.17 4.5 0.27 6.8 4.31 4.8 109.5 123 5.47 139 DC control circuit 2xM4 1.77 45 5.85 148.5 2 x ØM4 2.7 70 LD5LB130 + LB1LB03P••. 0.27 6.8 3.09 78.5 INTEGRAL 18 Non-Reversing and Reversing AC control circuit LD1LB030 Common side view + LB1LB03P•• 7.56 192 6.24 158.5 INTEGRAL 63 Mounting on 75 mm DIN rail 0.39 (AM1 DE200) 10 0.39 (AM1-DE200) 10 2.60 66 7.56 192 01/00 3.84 97.5 1.10 28 © 2000 Schneider Electric All Rights Reserved 3.95 1.17 100.5 45 8.27 210 5.06 128.5 7.17 182 6.10 155 10.47 266 5.41 137.5 3.66 93 3.5 89 1.77 45 = = 3.54 90 0.65 16.5 5.47 139 5.85 148.5 2.76 70.5 3.07 78 LA9LD010 4xM4 47 INTEGRAL™ Self-Protected Combination Motor Controllers Dimensions Auxiliary blocks Mounting on INTEGRAL 18 self-protected CMCs LA1LB031 LA1LB0311 LA1LB034LA1LB080BD LA1LB0341LA4D b LA1B015/017/019 LA1LB001 LA1LB080BD 0.43 11 0.47 12 0.47 12 0.47 12 b = 0.75 in (19 mm) LA4DA, DE, DF, DT b = 0.5 in (12 mm) LA4DL, DM, DR, DW b = 0.75 in (19 mm) Auxiliary blocks Mounting on INTEGRAL 32 and 63 self-protected CMCs LA1LC012 LA1LC001 LA1LC010 LA1LC07• LA1LC052 LA1LC020 LA1LC030 (1 or 2) LA1LC025 LA1lC001 LA1LC010 LA1LC001 LA1LC001 LA1LC012 0.50 13 LA1LC025 LA1LC070 LA1LC071 LA1LC072 0.43 11 1.02 26 2.01 51 0.35 9 0.47 12 0.35 9 0.47 12 Dual Dimensions inches mm 0.43 11 Auxiliary blocks Mounting on INTEGRAL 18 self-protected CMCs LA4D•• b LA1B015/017/019 LA1LB021, LA1LB001 LA1LB080BD 0.43 11 0.47 0.47 12 12 b = 0.75 in (19 mm) LA4DA, DE, DF, DT b = 0.5 in (12 mm) LA4DL, DM, DR, DW b = 0.75 in (19 mm) 0.43 11 Auxiliary blocks Mounting on INTEGRAL 32 and 63 self-protected CMCs LA1LC021, LC025 LA1LC001 LA1LC031 LA1LC012 LA1LC001 LA1LC001 LA1LC031 LA1LC001 LA1LC021 LA1LC021 LA1LC012 LA1LC010 LA1LC07•• LA1LC052 LA1LC020 LA1LC010 LA1LC070 LA1LC071 LA1LC072 LA1LC025 LA1LC025 0.43 11 48 0.51 13 0.47 12 1.02 26 0.51 13 1.02 26 2.01 51 0.47 12 0.43 11 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Dimensions INTEGRAL 18 Adjustable door interlock mechanism LA9LB33• For mounting on LD1LB030 + LB•LB03P•• LD5LB130 + LB•LB03P•• Non-adjustable door interlock mechanism LA9LB32• For mounting on LD1LB030 + LB•LB03P•• LD5LB130 + LB•LB03P•• 7.09 - 13.39 180 - 340 1.77 45 5.85 148.5 5.28 134 2.13 54 3.90 99 54 = = 2.13 Ø43 2.56 65 2.49 3.54 = 90 = 1.42 = = 36 Door drillings 63.25 5.31 135 135 2.49 63.25 5.31 5.85 2.13 54 148.5 65 2.56 (1) Dual Dimensions inches mm 4xØ3.5 = = 2.13 54 (1) Thickness: 0.2 in (5 mm) max INTEGRAL 32 Adjustable door interlock mechanism LA9LC33• and LA9LC53• For mounting on LD4LC•30, LD5LC•30 Non-adjustable door interlock mechanism LA9LC32• and LA9LC52• For mounting on LD4LC•30 + LD5LC•30 2.13 54 6.69 - 12.60 170 - 320 0.75 19 = = = = 2.60 Door drillings = 3.35 85 3.90 99 66 = 0.75 19 5.31 135 3.15 80 3.15 80 3.15 3.15 80 80 7.17 182 2.13 54 1.30 33 5.20 132 65 2.56 3.15 80 3.15 80 182 3.15 3.15 80 7.17 80 65 2.56 (1) = = = = = 2.60 = = 1.30 33 5.20 132 54 2.13 = = 66 Ø43 = 3.35 85 3.90 99 4xØ3.5 2.13 54 (1) Thickness: 0.2 in (5 mm) max INTEGRAL 63 Adjustable door interlock mechanism LA9LC33• and LA9LC53• For mounting on LD4LD•30, LD5LD•30 Non-adjustable door interlock mechanism LA9LC32• and LA9LC52• For mounting on LD4LC•30 + LD5LC•30 = = = = 3.54 90 Door drillings 1.10 28 2.32 2.48 2.32 59 63 59 7.13 181 1.77 45 2.13 54 6.77 (LD4) 172 6.85 (LD5) 174 = 1.10 28 3.54 4.13 105 105 10.83 275 2.32 59 2.48 2.32 63 59 1.77 45 7.13 181 54 2.13 = = = 4.13 105 4.13 = = = = 90 Ø43 243 105 105 9.57 4.13 4.13 65 2.56 4.13 105 4.13 105 4.13 105 8.15 - 14.06 (LD4) 207 - 357 8.23 - 14.13 (LD5) 209 - 359 2.13 54 10.83 275 2.56 65 4.13 105 9.57 243 4.13 105 (1) 4xØ3.5 (1) Thickness: 0.2 in (5 mm) max 2.13 54 01/00 © 2000 Schneider Electric All Rights Reserved 49 INTEGRAL™ Self-Protected Combination Motor Controllers Dimensions INTEGRAL 18 contactor breakers and reversing contactor breakers Flush mounting 0.79 20 20 a1 0.04 1 (1) 1.81 46 = = (2) a 0.79 0.16 4 Safety clearance a2 0.08 2 a a1 a2 LD1LB030 1.81/46 – – LD5LB130 3.94/100 – – LA1LB0•• – 0.53/13.5 – 2 x LA1LB0•• – – 1.06/27 Dual Dimensions inches mm (1) Center of operating knob (2) Mounting center INTEGRAL 32 contactor breakers and reversing contactor breakers Flush mounting Safety clearance a2 a a1 a2 LD1LC030 2.6/66 – – LD4LC•30 2.6/66 – – LD1LC040 3.35/85 – – LD4LC•40 3.35/85 – – LD5LC•30 4.8/122 – – LA1LC010 – 0.51/13 – LA1LC012 – 0.51/13 – LA1LC010 + LA1LC052• – – 2.01/51 LA1LC012 + LA1LC052• – – 2.01/51 0.79 20 a1 0.04 1 (2) 1.81 46 = = (3) a 0.79 20 0.16 (1) 4 (1) Maximum door thickness for interlocking by LD4 and LD5 (2) Center of operating knob (2) Mounting center INTEGRAL 18 contactor breakers and reversing contactor breakers Flush mounting Safety clearance a1 a2 0.04 1 (2) 1.81 46 = = (3) a a a1 a2 LD1LD030 3.54/90 – – LD4LD•30 3.54/90 – – LD5LD•30 7.13/181 – – LA1LC010 – 0.51/13 – LA1LC012 – 0.51/13 – LA1LC010 + LA1LC052• – – 2.01/51 LA1LC012 + LA1LC052• – – 2.01/51 1.18 30 1.18 30 0.16 (1) 4 (1) Maximum door thickness for interlocking by LD4 and LD5 (2) Center of operating knob (2) Mounting center 50 © 2000 Schneider Electric All Rights Reserved 01/00 INTEGRAL™ Self-Protected Combination Motor Controllers Dimensions INTEGRAL Enclosures Type 1 B C B 8 203 B B 10 254 2.5 64 3 76 C 2.5 64 5 127 7.5 191 7.5 191 A 12.5 318 16.5 419 A 18 457 14 356 Knockouts A = 0.5 in (12.7 mm) Dia. A B = 1.0 to 1.25 in (25.4 to 31.8 mm) Dia. A C = 0.5 to 0.75 in (12.7 to 19 mm) Dia. Provision for 0.25 screw 6.4 Provision for 0.25 screw 6.4 INTEGRAL 18 FVNR and FVR INTEGRAL 32 FVNR and FVR INTEGRAL 32 FVR INTEGRAL 63 FVNR Dual Dimensions inches mm Type 12 10 254 8 203 3 76 2.5 64 5 127 2.5 64 0.38/9.5 7.75 197 7.75 197 15.63 397 19.63 498 18 457 14 356 14.88 378 18.88 479 0.38/9.5 0.44/11 0.44/11 Provision for 0.25 screw 6.4 Provision for 0.25 screw 6.4 INTEGRAL 18 FVNR and FVR INTEGRAL 32 FVNR 01/00 INTEGRAL 32 FVR INTEGRAL 63 FVNR © 2000 Schneider Electric All Rights Reserved 51 Square D Company 8001 Highway 64 East Knightdale, NC 27545 USA (919) 266-3671 www.squared.com Schneider Canada Inc. 19 Waterman Avenue, M4B 1 Y2 Toronto, Ontario (416) 752-8020 www.schneider.ca Catalog No. 8539CT9201R11/99 January 2000. Replaces 8539CT9201R6/97 dated June 1997.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2000:01:20 11:53:49Z Modify Date : 2003:08:14 13:42:26-05:00 DCTM Object Id : 09008926800d877f Tag DCTM Object Title : INTEGRAL¿ Self-Protected Combination Motor Controllers Tag DCTM Requested By : dmadmin DCTM Docbase Id : 35110 Tag DCTM Docbase Name : sena_roy Tag DCTM Source Content Type : maker Page Count : 52 Page Mode : UseOutlines Creation Date : 2000:01:20 11:53:49Z Producer : Acrobat Distiller 3.0 for Power Macintosh Author : Mod Date : 2003:08:14 13:42:26-05:00 Metadata Date : 2003:08:14 13:42:26-05:00 Creator : Title : INTEGRAL¿ Self-Protected Combination Motor ControllersEXIF Metadata provided by EXIF.tools