for the Warmup tempo Digital Programmable Thermostat
Part of the Element Series
Introduction
The tempo thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup
underfloor heating system. The thermostat is designed to receive temperature input signals from the following
sensors:
1. Air sensor located inside the thermostat
2. Floor sensor installed in the floor to be heated (see Warmup heater instructions for details)
The thermostat is not a safety device and should only be used with Warmup heating products. In order to avoid
damaging your flooring the correct floor type must be selected during the thermostat programming process.
Electrical Specification:
• Supply voltage: 230V +/-15% at 50Hz
• Thermostat is not designed for use with intermittent power supply.
• Maximum Switch Load: 16A resistive
• Insulation Class : II
• Housing : IP20
• Sensor NTC : 10K @ 25°C
• Standards: EN60730-1 & EN60730-2-9
• Meets LVD and EMC directives for safety and electromagnetic compatibility
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should
always isolate the power supply before attempting to install or repair the tempo thermostat. The thermostat should
not be put into operation unless you are certain that the entire heating installation complies with current general
safety requirements for electrical installations. Electrical installation must be in accordance with the latest IEE Wiring
Regulations and appropriate Statutory Regulations.

Thermostat location
The thermostat should be installed inside a single gang electrical wall box that is at least 32mm deep. For optimal
performance, the thermostat should be located in an area with good ventilation. It should not be installed beside a
drafty window/door, in direct sunlight or above another heat generating device (e.g. Radiator or TV).
The thermostat is designed for operation between 0°C and 50°C with relative humidity less than 80%.

Location and installation of floor sensor
The optimum location of the floor sensor is described in each Warmup heater installation manual. Refer to that manual
when selecting floor sensor location.
Warmup recommend the use of conduit when installing the floor sensor. The conduit will protect the sensor and will
allow easier repair of the sensor in the case of sensor damage after flooring has been laid.

Installation:
Separate the front housing of thermostat from the wall module:
1. Unscrew both closing screws (bottom of thermostat) until they will not turn any
further.
2. Release front housing by gripping the lower half of outer frame and pulling
outwards then upwards.
3. Place front housing somewhere safe.
4. Run all wires to the wall box. Check to ensure that you have included the
following:
• Power (Live and Neutral)
• Heater (Live and Neutral)
• Floor sensor
• Fil pilote (France only)
5. Pull wires through the wall box and complete terminal wiring.

1
2
3
4

IMPORTANT: Ensure that multi strand wires are fully inserted into the terminal and
secured tightly. Any loose strands should be trimmed as they could cause a
short-circuit.
If connecting more than two heaters, an electrical junction box will be required.
ELT-01-XX-01 - Installation guide V1.0 © Warmup plc - 2013

Normal electrical installation (see numbering on diagram to right)
1.
2.
3.
4.
5.
6.
7.
8.

Connect to Fil Pilote (F.P.) - only for use in France
Connect to Power Supply (Live – MAX 240V)
Connect to Power Supply (Neutral – MAX 240V)
Connect to Warmup heater(s) (Neutral – MAX 3600W/ 16 Amps)
Connect to Warmup heater(s) (Live – MAX 3600W/ 16 Amps)
Not Used
Connect to 1st wire of floor sensor (colour not important)
Connect to 2nd wire of floor sensor (colour not important)

(NOT USED)

20

Mounting thermostat into the wall box
1. Push excess wire back through the wall box and insert
thermostat back module into wall box.
2. Put fixing screws through mounting holes and tighten.
3. Ensure that thermostat is straight before tightening completely.
4. Replace thermostat front housing:
• Align and sit front housing on to hinges
• Push lower half of front housing until a ‘click’ is heard.
5. Ensure front housing is securely fixed.
6. IMPORTANT: Tighten both retaining screws.

Powering-up
You can now power-up the thermostat and begin the programming
process.

Contact Warmup
UK
Warmup Plc
702 Tudor Estate
Abbey Road
London
NW10 7UW
T: 0845 345 2288
International: + 44 208 453 6868
F: 0845 345 2299
E-mail: uk@warmup.com
Website: www.warmup.co.uk

Patent Pending
Disposal
Appliances with this symbol must
not be disposed of with general
waste. Seek guidance from your local
government or the retailer where you
purchased the product.
ELT-01-XX-01 - Installation guide V1.0 © Warmup plc - 2013



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:03:18 12:12:05Z
Metadata Date                   : 2014:03:18 12:12:10Z
Modify Date                     : 2014:03:18 12:12:10Z
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:1fae1dd4-7b29-44d8-afa4-1f3dc67ad705
Original Document ID            : xmp.did:AD3983DD14A9DF11BD9BA774D2AC62AE
Document ID                     : xmp.id:19FAA67896AEE31183AEC220C4A056F7
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:18FAA67896AEE31183AEC220C4A056F7
Derived From Document ID        : xmp.did:92C95924DC92E211B715A6289068F192
Derived From Original Document ID: xmp.did:AD3983DD14A9DF11BD9BA774D2AC62AE
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:03:18 12:12:05Z
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu