T6______qreng0100 The Fluke T6 1000 Electrical Er User Manual Brochure
User Manual: The-FlukeT6-1000-Electrical-er-User-Manual-Brochure
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Symbols Overview Quick Reference Guide GuÍa de referencia rápida Guia de referência rápida 1 Wire Position 200 A Electrical Tester 1000 V CAT 600 V CAT T6-600/T6-1000 with FieldSense Technology 1 Wire Only » �� See “Safety Information”. Go to www.fluke.com to register your product and find more information, or download this Quick Reference Guide in other languages. Consulte las “Información sobre seguridad”. Vaya a www.fluke.com para registrar el producto y obtener más información, o descargue esta Guía de referencia rápida en otros idiomas. Consulte o “Informações de Segurança”. Acesse www.fluke.com.br para registrar seu produto e obter mais informações, ou baixe este Guia de referência rápida em outros idiomas. 2 Finger Guard For safe operation, hold the Tester behind the finger guard. HOLD 1000 V CAT 600 V CAT 200 A Test with fork and FieldSense ground contact. Consult user documentation. Test with fork and ground probe. Hazardous voltage ≥30 V. Test with probes. Battery full charge. FieldSense Measurement: Fluke voltage/current sensing technique. Battery low. Replace. Good earth ground connection. Back light No earth ground connection. 1 6 3 Display LD Model T6-1000 Hz Field e Sens Model T6-600 3 4 4 X Hazardous Voltage ≥30 V AUTO SELECT T6-1000 ELECTRICAL TESTER 7 5 Function Selection/On/Off 6 FieldSense Ground Contact Auto Off 15 min © 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notification. 7 Test Probes/Storage Dock info@Fluke-Direct.com Requires Test Leads Range Range TP1 Probe Set, Flat-Blade PN 648128 Battery Door PN 4944370 Battery Door Screw PN 1618579 Use only specified replacement parts. Accuracy [1] Resolution No 1000 V 600 V 1V ±(3 % + 3 counts) 45 Hz to 66 Hz [2][3] FieldSense Current ac No 200.0 A 200.0 A 0.1 A ±(3 % + 3 counts) 45 Hz to 66 Hz FieldSense Frequency (Hz) No 1 Hz ±(1 % + 2 counts) [3] 45 Hz to 66 Hz Voltage ac Yes 1000 V 600 V 1V ±(1.5 % + 2 counts) 45 Hz to 66 Hz Accessories Voltage dc Yes 1000 V 600 V 1V ±(1 % + 2 counts) Yes 2000 Ω 2000 Ω 1Ω Yes 20.00 kΩ 0.01 kΩ ● ● ● ● ● Yes 100.0 kΩ 0.1 kΩ ±(1 % + 2 counts) [1] Accuracy: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac coupled, RMS responding. [2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. [3] FieldSense is specified from 16 V to 100 % of range. Fork Opening 17.8 mm Calibration 1-year calibration cycle Temperature Operating Storage -10 °C to +50 °C (+14 °F to +122 °F) -30 °C to +60 °C (-22 °F to +140 °F) Altitude PN 4897598 September 2017 Rev. 1, 10/17 PN 4462973 Lead Replacement FieldSense Voltage ac Resistance 5 Test Lead Assembly (T5-RLS) Replace only with Fluke double-insulated leads (T) Model T6-1000 Model T6-600 Function 2 HOLD WARNING. RISK OF DANGER. Specifications Fork Opening 17.8 mm HO Replacement Parts Operating Storage 2000 m 10 000 m Relative Humidity 0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F) 0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F) 0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F) Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function Temperature coefficient 0.1 x (specified accuracy) / °C for <18 °C or >28 °C (<64.4 °F or >82.4 °F) Fluke-Direct .com 1.888.610.7664 HT6 Belt Holster TPAK Hanger PRV240FS AC285 SureGrip™ Alligator Clips AC220 SureGrip™ Alligator Clips How to Make Measurements Model T6-1000 / / / Model T6-600 / / / HOLD Tips: FieldSense Technology HOLD 1 1 Use the black probe to make the ground connection if: ● wearing gloves or insulated footwear 1 1 1 HOLD HOLD 1 HOLD HOLD HOLD HOLD ● standing on an insulated ladder ● additional ground contact is required for the application W Do not hold or touch wire during a measurement. Hz Hz Hz FieldSense measurement looks like this when properly grounded: AUTO SELECT T6 - 600 T6 - 600 ELECTRICAL TESTER 2 2 Use the Ground Probe Insert Test Probes into the storage dock 45 Hz - 66 Hz T6-600 max: 600 V rms CAT III T6-1000 max: 1000 V rms CAT III 600 V rms CAT IV 2A CAT AUTOInsert Test Probes SELECT into the storage dock AUTO SELECT If you see: T6 - 600 T6 - 600 ELECTRICAL TESTER 3 3 Ground Contact ● Display color is gray ● VAC measurement does not show on display ● Measurement is <16 V ● Check the wire position in the fork opening. See the section about wire position. se ElecT6 tric 10 al Te 00 ste r en ldS Hz 4 / 600 V CAT 4 5 200 A 600 V CAT 200 A AUTO SELECT HOLD Low Battery Indicator T6 - 600 ELECTRICAL TESTER HOLD CAT T6 - 600 ELECTRICAL TESTER = Hz = CAT = Fluke-Direct .com HOLD HOLD HOLD 1000 V CAT 600 V CAT 200 A HOLD AUTO SELECT = Hz 2 HOLD HOLD 1000 V CAT 600 V CAT 200 A 200 A HOLD Display turns green for valid measurement. See Tips. Display turns green for valid measurement. See Tips. 5 HOLD 1000 V CAT 600 V CAT 5 5 HOLD 200 A Display turns green for valid measurement. See Tips. Display turns green for valid measurement. See Tips. 1 600 V CAT 200 A 1000 V CAT 600 V CAT 200 A 1000 V CAT 600 V CAT 1000 V CAT 600 V CAT 200 A 200 A / Fie se ldS ElecT6 tric 10 al Te 00 ste r en 4 200 A shows on the display ● Display color is gray ● VAC measurement does not show on display HO Hz 4 HOLD ● LD HO LD T6-600 max: 600 V CAT III T6-1000 max: 1000 V CAT III 600 V CAT IV Fie (DC) 2B CAT hand firmly on CATHold FieldSense Hold hand firmly on FieldSense Ground Contact 2B ELECTRICAL TESTER 3 3 Solution: ● Make sure that your bare hand is firmly touching the FieldSense Ground Contact on the battery door. ● Check that the black probe is properly stored in the dock. ● Check the wire position in the fork opening. See the section about wire position. 1000 V CAT 600 V CAT (AC) ELECTRICAL TESTER CAT 600 V CAT 2A 2 2 Use the Ground Probe ● Display color turns green ● Display shows a valid measurement >16 V rather than dashes or 0.0 ● Y shows for measurement ≥30 V AUTO SELECT info@Fluke-Direct.com 1.888.610.7664 Do not overtighten screw 2 AA
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.6 Linearized : No Page Count : 2 Warning : Duplicate 'ProcSet' entry in dictionary (ignored) Creator : Adobe Illustrator(R) 17.0 For : Craven, Amy, Title : T6______qreng0100.pdf Create Date : 9/22/2017 12:23 PM Bounding Box : -127 -1380 2135 -813 Container Version : 12 Creator Version : 21EXIF Metadata provided by EXIF.tools