Symbols

Overview

Quick Reference Guide
GuÍa de referencia rápida
Guia de referência rápida

1 Wire Position
200 A

Electrical Tester

1000 V CAT
600 V CAT

T6-600/T6-1000
with FieldSense Technology

1 Wire Only

»
�� See “Safety Information”.
Go to www.fluke.com to register your product and find more information, or
download this Quick Reference Guide in other languages.
Consulte las “Información sobre seguridad”.
Vaya a www.fluke.com para registrar el producto y obtener más información, o
descargue esta Guía de referencia rápida en otros idiomas.
Consulte o “Informações de Segurança”. Acesse www.fluke.com.br para
registrar seu produto e obter mais informações, ou baixe este Guia de
referência rápida em outros idiomas.

2 Finger Guard
For safe operation,
hold the Tester behind
the finger guard.

HOLD

1000 V CAT
600 V CAT

200 A

Test with fork and FieldSense ground contact.

Consult user documentation.

Test with fork and ground probe.

Hazardous voltage ≥30 V.

Test with probes.

Battery full charge.

FieldSense Measurement:
Fluke voltage/current sensing technique.

Battery low. Replace.

Good earth ground connection.

Back light

No earth ground connection.

1
6

3 Display

LD

Model T6-1000
Hz

Field

e
Sens

Model T6-600

3
4
4 X Hazardous Voltage ≥30 V

AUTO
SELECT

T6-1000

ELECTRICAL TESTER

7

5 Function Selection/On/Off
6 FieldSense

Ground Contact

Auto Off
15 min

© 2017 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.

7 Test Probes/Storage Dock

info@Fluke-Direct.com

Requires
Test Leads

Range

Range

TP1 Probe Set, Flat-Blade

PN 648128

Battery Door

PN 4944370

Battery Door Screw

PN 1618579

Use only specified replacement parts.

Accuracy [1]

Resolution

No

1000 V

600 V

1V

±(3 % + 3 counts)
45 Hz to 66 Hz [2][3]

FieldSense
Current ac

No

200.0 A

200.0 A

0.1 A

±(3 % + 3 counts)
45 Hz to 66 Hz

FieldSense
Frequency (Hz)

No

1 Hz

±(1 % + 2 counts) [3]

45 Hz to 66 Hz

Voltage ac

Yes

1000 V

600 V

1V

±(1.5 % + 2 counts)
45 Hz to 66 Hz

Accessories

Voltage dc

Yes

1000 V

600 V

1V

±(1 % + 2 counts)

Yes

2000 Ω

2000 Ω

1Ω

Yes

20.00 kΩ

0.01 kΩ

●
●
●
●
●

Yes

100.0 kΩ

0.1 kΩ

±(1 % + 2 counts)

[1] Accuracy: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration,
at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac coupled, RMS responding.
[2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated
gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specified from 16 V to 100 % of range.

Fork Opening

17.8 mm

Calibration

1-year calibration cycle

Temperature
Operating
Storage

-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)

Altitude

PN 4897598 September 2017 Rev. 1, 10/17

PN 4462973

Lead Replacement

FieldSense
Voltage ac

Resistance

5

Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated
leads (T)

Model T6-1000 Model T6-600
Function

2

HOLD

WARNING. RISK OF DANGER.

Specifications

Fork Opening 17.8 mm

HO

Replacement Parts

Operating
Storage

2000 m
10 000 m

Relative Humidity

0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F)

Battery Type and Life

2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function

Temperature coefficient

0.1 x (specified accuracy) / °C for <18 °C or >28 °C (<64.4 °F or >82.4 °F)

Fluke-Direct .com

1.888.610.7664

HT6 Belt Holster
TPAK Hanger
PRV240FS
AC285 SureGrip™ Alligator Clips
AC220 SureGrip™ Alligator Clips

How to Make Measurements
Model T6-1000

/

/

/

Model T6-600

/

/ /
HOLD

Tips: FieldSense Technology

HOLD
1

1

Use the black probe to make the ground connection if:
● wearing gloves or insulated footwear

1

1

1
HOLD

HOLD

1
HOLD

HOLD

HOLD

HOLD

● standing on an insulated ladder
● additional ground contact is required for the application

W Do not hold or touch wire during a measurement.

Hz

Hz

Hz

FieldSense measurement looks like this when properly grounded:
AUTO
SELECT

T6 - 600

T6 - 600

ELECTRICAL TESTER

2

2

Use the Ground Probe

Insert Test Probes
into the storage dock

45 Hz - 66 Hz
T6-600 max: 600 V rms CAT III
T6-1000 max: 1000 V rms CAT III
600 V rms CAT IV

2A

CAT

AUTOInsert Test Probes
SELECT
into the storage dock

AUTO
SELECT

If you see:

T6 - 600

T6 - 600

ELECTRICAL TESTER

3

3

Ground Contact

● Display color is gray
● VAC measurement
does not show on
display

● Measurement is <16 V
● Check the wire position in the
fork opening. See the section
about wire position.

se

ElecT6 tric 10
al Te 00
ste
r

en
ldS

Hz

4

/

600 V CAT

4

5

200 A

600 V CAT

200 A

AUTO
SELECT

HOLD

Low Battery
Indicator

T6 - 600

ELECTRICAL TESTER

HOLD

CAT

T6 - 600

ELECTRICAL TESTER

= Hz

=

CAT

=

Fluke-Direct .com
HOLD

HOLD

HOLD

1000 V CAT
600 V CAT

200 A

HOLD

AUTO
SELECT

= Hz

2

HOLD

HOLD

1000 V CAT
600 V CAT

200 A

200 A

HOLD

Display turns
green for valid
measurement.
See Tips.

Display turns
green for valid
measurement.
See Tips.

5

HOLD

1000 V CAT
600 V CAT

5

5

HOLD

200 A

Display turns
green for valid
measurement.
See Tips.

Display turns
green for valid
measurement.
See Tips.

1

600 V CAT

200 A

1000 V CAT
600 V CAT

200 A

1000 V CAT
600 V CAT

1000 V CAT
600 V CAT

200 A

200 A

/

Fie

se
ldS

ElecT6 tric 10
al Te 00
ste
r

en

4

200 A

shows on the
display
● Display color is gray
● VAC measurement
does not show on
display

HO

Hz

4

HOLD

●

LD

HO

LD

T6-600 max: 600 V CAT III
T6-1000 max: 1000 V CAT III
600 V CAT IV

Fie

(DC)

2B
CAT

hand firmly on
CATHold
FieldSense

Hold hand firmly on
FieldSense
Ground Contact

2B

ELECTRICAL TESTER

3

3

Solution:
● Make sure that your bare hand
is firmly touching the FieldSense
Ground Contact on the battery
door.
● Check that the black probe is
properly stored in the dock.
● Check the wire position in the
fork opening. See the section
about wire position.

1000 V CAT
600 V CAT

(AC)

ELECTRICAL TESTER

CAT

600 V CAT

2A

2

2

Use the Ground Probe

● Display color turns green
● Display shows a valid measurement >16 V
rather than dashes or 0.0
● Y shows for measurement ≥30 V

AUTO
SELECT

info@Fluke-Direct.com

1.888.610.7664

Do not
overtighten
screw
2 AA



Source Exif Data:
File Type                       : AI
File Type Extension             : ai
MIME Type                       : application/vnd.adobe.illustrator
PDF Version                     : 1.6
Linearized                      : No
Page Count                      : 2
Warning                         : Duplicate 'ProcSet' entry in dictionary (ignored)
Creator                         : Adobe Illustrator(R) 17.0
For                             : Craven, Amy,
Title                           : T6______qreng0100.pdf
Create Date                     : 9/22/2017 12:23 PM
Bounding Box                    : -127 -1380 2135 -813
Container Version               : 12
Creator Version                 : 21
EXIF Metadata provided by EXIF.tools

Navigation menu