T6______qreng0100 The Fluke T6 1000 Electrical Er User Manual Brochure
User Manual: The-FlukeT6-1000-Electrical-er-User-Manual-Brochure
Open the PDF directly: View PDF .
Page Count: 2
HOLD
Hz
FieldSense
3
2
1
5
7
6
HOLD
200 A
CAT
1000 V
CAT 600 V
4
HOLD
200 A
CAT
1000 V
CAT 600 V
AUTO
SELECT
T6-100 0
ELECTRICAL TESTER
5
2
7
3
1
4
6
Accessories
● HT6 Belt Holster
● TPAK Hanger
● PRV240FS
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated
leads (T)
TP1 Probe Set, Flat-Blade
Battery Door
Battery Door Screw
PN 4462973
PN 648128
PN 4944370
PN 1618579
Use only specified replacement parts.
Replacement Parts
Lead Replacement
Symbols
Function Range
Requires
Test Leads Resolution Accuracy [1]
Range
Model T6-600
Specifications
Model T6-1000
No
200.0 A
45 Hz to 66 Hz
100.0 kΩ
20.00 kΩ
Voltage ac
Current ac
Frequency (Hz)
Voltage ac
Voltage dc
Resistance
No
No
Yes
Yes
Yes
Yes
Yes
±(1 % + 2 counts) [3]
±(1 % + 2 counts)
±(1 % + 2 counts)
200.0 A
±(3 % + 3 counts)
45 Hz to 66 Hz [2][3]
±(3 % + 3 counts)
45 Hz to 66 Hz
±(1.5 % + 2 counts)
45 Hz to 66 Hz
0.1 A
0.1 kΩ
0.01 kΩ
[1] Accuracy: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration,
at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac coupled, RMS responding.
[2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated
gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specified from 16 V to 100 % of range.
Fork Opening 17.8 mm
Calibration 1-year calibration cycle
Temperature
Operating -10 °C to +50 °C (+14 °F to +122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
Relative Humidity 0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coefficient 0.1 x (specified accuracy) / °C for <18 °C or >28 °C (<64.4 °F or >82.4 °F)
Test with fork and FieldSense ground contact.
Test with fork and ground probe.
Test with probes.
FieldSense Measurement:
Fluke voltage/current sensing technique.
Good earth ground connection.
No earth ground connection.
WARNING. RISK OF DANGER.
Consult user documentation.
Battery full charge.
Back light
Battery low. Replace.
Hazardous voltage ≥30 V.
Overview
Finger Guard
Wire Position
Display
Function Selection/On/Off
1 Wire Only
FieldSense
Ground Contact
For safe operation,
hold the Tester behind
the finger guard.
XHazardous Voltage ≥30 V
Auto Off
15 min
Test Probes/Storage Dock
Model T6-600Model T6-1000Model T6-1000
�� See “Safety Information”.
Go to www.fluke.com to register your product and find more information, or
download this Quick Reference Guide in other languages.
Consulte las “Información sobre seguridad”.
Vaya a www.fluke.com para registrar el producto y obtener más información, o
descargue esta Guía de referencia rápida en otros idiomas.
Consulte o “Informações de Segurança”. Acesse www.fluke.com.br para
registrar seu produto e obter mais informações, ou baixe este Guia de
referência rápida em outros idiomas.
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
Quick Reference Guide
GuÍa de referencia rápida
Guia de referência rápida
Fork Opening 17.8 mm
PN 4897598 September 2017
© 2017 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
»
PN 4897598 September 2017 Rev. 1, 10/17
© 2017 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
FieldSense
FieldSense
FieldSense
1000 V
1000 V
1000 V
2000 Ω 2000 Ω
600 V
600 V
600 V
1 V
1 V
1 V
1 Hz
1 Ω
2000 m
10 000 m
PN 1618579
PN 4944370
PN 648128
PN 4462973
1.888.610.7664 info@Fluke-Direct.com
Fluke-Direct
.com
HOLD
200 A
CAT
1000 V
CAT 600 V
2
1
HOLD
200
A
CAT 1000 V
CAT
600 V
HOLD
1
2A
2B
HOLD
T6 - 6 00
ELECT RICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 6 0 0
ELECTRICAL TEST ER
AUTO
SELECT
CAT
CAT 6 00 V
200 A
1
2
4
3
5
CAT 600 V
200 A
=
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 6 00
ELECT RICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 6 0 0
ELECTRICAL TEST ER
AUTO
SELECT
CAT
CAT 6 00 V
200 A
1
2
4
3
5
HOLD
CAT 600 V
200 A
=
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
T6 - 1000
Electrical Tester
HOLD
Hz
FieldSense
/ /
HOLD
HOLD
200 A
CAT
1000 V
CAT 600 V
HOLD
200 A
CAT
1000 V
CAT 6 00 V
1
2
4
3
5
=Hz
HOLD
HOLD
200 A
CAT
1000 V
CAT 600 V
1
2
4
3
5
/ / /
/
/
T6 - 1000
Electrical Tester
HOLD
Hz
FieldSense
Hz Hz
Hz
HOLD
200 A
CAT
1000 V
CAT 6 00 V
=Hz
HOLD
/
1
2B
2A
HOLD
(DC)
(AC)
HOLD
200 A
CAT
1000 V
CAT 600 V
HOLD
Tips: FieldSense Technology
● shows on the
display
● Display color is gray
● VAC measurement
does not show on
display
● Display color turns green
● Display shows a valid measurement >16 V
rather than dashes or 0.0
● Y shows for measurement ≥30 V
● Measurement is <16 V
● Check the wire position in the
fork opening. See the section
about wire position.
● Display color is gray
● VAC measurement
does not show on
display
Use the black probe to make the ground connection if:
● wearing gloves or insulated footwear
● standing on an insulated ladder
● additional ground contact is required for the application
W Do not hold or touch wire during a measurement.
If you see: Solution:
FieldSense measurement looks like this when properly grounded:
Do not
overtighten
screw
Low Battery
Indicator
● Make sure that your bare hand
is firmly touching the FieldSense
Ground Contact on the battery
door.
● Check that the black probe is
properly stored in the dock.
● Check the wire position in the
fork opening. See the section
about wire position.
Display turns
green for valid
measurement.
See Tips.
Display turns
green for valid
measurement.
See Tips.
Hold hand firmly on
FieldSense
Ground Contact
Insert Test Probes
into the storage dock
Use the Ground Probe
Display turns
green for valid
measurement.
See Tips.
Display turns
green for valid
measurement.
See Tips.
Use the Ground Probe
Insert Test Probes
into the storage dock
Hold hand firmly on
FieldSense
Ground Contact
T6-600 max: 600 V CAT III
T6-1000 max: 1000 V CAT III
600 V CAT IV
45 Hz - 66 Hz
T6-600 max: 600 V rms CAT III
T6-1000 max: 1000 V rms CAT III
600 V rms CAT IV
How to Make MeasurementsHow to Make Measurements
Model T6-600
Model T6-1000
2 AA
1.888.610.7664 info@Fluke-Direct.com
Fluke-Direct
.com