VFE2500 LINEAR MECHANICAL R
User Manual: VFE2500 LINEAR MECHANICAL r
Open the PDF directly: View PDF .
Page Count: 29
Download | |
Open PDF In Browser | View PDF |
MOVFE 2500 LINEAR DOOR OPERATOR MECHANICAL MANUAL GAL CANADA 6500 Gottardo Court Mississauga, Ontario L5T 2A2 Canada 1 (416) 747-7967 1 (800) 446-4850 http://www.galcanada.com M LINEAR 2500-3071 FOREWORD It is the intent of this manual to give the reader certain key points of information critical to the proper installation of the door operator. It is not intended to give comprehensive installation procedures nor does it cover the installation of door headers, track, hangers, etcetera. It is hoped that the procedures presented in this manual will reduce the installation and adjustment time and result in a smooth, long lasting door operation. When properly installed, GAL door operators will give many years of trouble free service. COMMENTS: All GAL door operators are factory adjusted and tested for the actual job requirements. When installed correctly, they may require minor adjustments to suit actual job conditions. IMPORTANT NOTES: All equipment must be installed, adjusted, tested and maintained to comply with all Federal, State/Provincial, and Local codes. Kinetic Energy and Stall Force must be adjusted to comply with ASME, A17.1, Rule 112.4/5, and CSA/B44, Rule 2.13.4/5. Before mounting the operator, check that the car door is plumb, free and moves easily without bind. Check the attached standard measurement sheets. Install the operator according to the measurements supplied. Contact GAL if the following label is missing from the door operator. I TABLE OF CONTENTS Foreword Comments & Important Notes Table of Contents I I II ILLUSTRATIONS OF MOVFE2500 LINEAR DOOR OPERATORS Left Hand Heavy Duty Linear Model Right Hand Heavy Duty Linear Model Center Parting Heavy Duty Linear Model A Left Hand Light Duty Linear Model 1 1 1 2 2 DETERMINING THE HAND OF THE DOOR Right Hand Door Left Hand Door 3 3 3 MECHANICAL SETUP INSTRUCTIONS 4 KINETIC ENERGY, AND ASME A17.1 2000 FOR ELEVATOR DOOR SYSTEMS Code Closing Distance / Time Average Kinetic Energy (7.37 ft-lbs) Actual (peak) Kinetic Energy (17ft-lbs) Nudging Kinetic Energy (2.5 ft-lbs) Non Standard Systems 2.13.4.2.4 Data Plate 2.13.4.2.1 Kinetic Energy 8 8 8 8 8 8 8 9 HEAVY DUTY LINEAR MODEL MINIMUM CLOSING TIME FOR SINGLE SPEED S/O DOOR 10 MINIMUM CLOSING TIME FOR TWO SPEED S/O DOOR 11 MINIMUM CLOSING TIME FOR SINGLE SPEED C/P DOOR 12 MINIMUM CLOSING TIME FOR TWO SPEED C/P DOOR 13 LIGHT DUTY LINEAR MODEL MINIMUM CLOSING TIME FOR SINGLE S/O DOOR 14 MINIMUM CLOSING TIME FOR TWO SPEED S/O DOOR 15 MINIMUM CLOSING TIME FOR SINGLE SPEED C/P DOOR 16 MINIMUM CLOSING TIME FOR TWO SPEED C/P DOOR 17 II PARTS LIST 18 NOTES & COPYRIGHT 26 NOTES III ILLUSTRATIONS OF THE MOVFE2500 LINEAR DOOR OPERATORS MOVFE2500 linear door operator utilizes a ½ HP AC motor for the heavy duty models and 91W AC geared motor for light duty models. The controller includes a closed-loop VVVF Drive, 3 basic halleffect sensor boards, 1 optional hall-effect sensor board for the narrower door, and an optional I/O board for special jobs. The following illustrations show 3 available models for each type: Right hand, Left hand and Center Parting. DDDDD DPM DCL DOL AUX RIGHT HAND HEAVY DUTY LINEAR MODEL DOL D RRRRRR DPM DCL DPM AUX DOL LEFT HAND HEAVY DUTY LINEAR MODEL 1 DCL DPM AUX DOL CENTRE PARTING HEAVY DUTY LINEAR MODEL DCL DPM AUX DOL LEFT HAND 2 SPEED LIGHT DUTY LINEAR MODEL 2 DETERMINING THE HAND OF THE DOOR GAL door operators are available for Right hand doors, Left hand doors and Center Parting doors. To determine the hand of the door, stand in the lobby facing the elevator door(s). If the door closes to the Left, it is a Left hand door. If the door closes to the Right it is a Right hand door. The Left hand, Center parting and Right hand operators are field interchangeable. Figures below illustrate the door hand. RIGHT HAND DOOR LEFT HAND DOOR 3 MECHANICAL SETUP INSTRUCTIONS Determine the door and hanger type of the system. I. Side Opening (S/O), left or right hand, and single-piece hanger. II. Side Opening (S/O), left or right hand, and two-piece hanger. III. Center parting (C/P) door and a single piece hanger. IV. Center parting (C/P) door and two piece hanger. 1. If the header has not yet been installed; mount the fixing strut # 19 onto the header before installing the header assembly. Fasten the header with five ½” bolts at a distance of 9¼” from the track rolling surface. The fixing strut length should be equal to or longer than the header width, as shown in the Fig.1 19 11 1/4" 9 1/4" Center line Top of track Figure 1 HEADER PLATE & TRACK 2. Check the distance from the door track centerline to the face of the header. Distance should be 1¼”. If the centerline of the track is farther than 1¼” from header, you need to shim the strut by the difference. Misalignment would cause wear and noise to the belt. 3. Install the car door hangers, if necessary. DCL DPM AUX DOL CENTRE PARTING 4 5 4 9 13 20 17 22 16 19 DPM DCL DOL AUX 18 6 14 21 10 15 2 12 1 3 8 11 7 SINGLE SLIDE RH SHOWN Figure 3 4. Mount the universal plate # 1 or # 23 (C/P) with bend towards the door open side using four 5/16” bolts. 5. For the two-piece hanger system, mount the extension arm # 2 or # 24 (C/P) to the opposite hanger and secure to the universal plate # 1 or # 23 with 5/16 bolts. 6. For the single-piece hanger system, mount the universal plate # 1 or # 23 directly to the hanger, using at least two 5/16” bolts. 7. Install the belt bracket # 3 onto the top of the universal plate # 1 or # 23 with the clutch roller facing the header. Use 3/8” bolts. 8. For the keeper clutch installation refer to Fig. 3 for S/O door, Or Fig. 4 for C/P doors. For the standard clutch assemblies, item # 7 and hook are not used. 9. Insert the drive pulley # 18 and pulley # 4 at the extreme ends of the fixing strut or header plate. For S/O doors, locate the motor control unit # 20 on the closing side, collinear with the header plate. For the C/P doors, locate the motor control unit # 20 on the right side looking from the hall. The two pulleys can be mounted reversed if the car top does not allow the space for the control Box # 22 on the correct side. 10. Hang the motor belt # 19 loosely onto the large pulley. 11. Position the DCL, DPM, DOL, and AUX. hall-effect sensors. Header plate comes pre-drilled, with 7/8" holes, with plastic window bushings, Heyco # 2874, for best cable protection. 12. Feed the hall sensor cables to the back of the header. Later, these will be inserted into the Signals transfer board inside the control box. # 22 5 25 DCL DPM Figure 4 24 23 AUX DOL CENTRE PARTING 13. Mount the tension block # 5 to the fixing strut. Put the hex screw toward the take up pulley. 14. With the door in fully opened position, install the open door stop # 9 in contact with the lower belt Bracket # 3. Firmly secure the stop. 15. Locate the gate switch assembly # 6 underneath large pulley at closed position. For S/O doors refer to Fig. 3. For C/P doors refer to Fig. 4.The gate switch roller # 11 on the Sheave bracket has to engage the flipper fully. To install the gate switch on a single piece hanger you will have to drill an 11/32” hole in the Hanger Tighten the gate switch assembly. 16. If the keeper style clutch is being used; mount the keeper bracket # 7 to the right for R.H. or left, for L.H. (item # 3 on Fig. 3) Secure the keeper bracket assembly. 17. With the door in fully closed position, place the clutch cam # 8 as shown in Fig. 3. Adjust the clutch cam so that the short release bar is fully retracted. With the door slightly open, adjust the eccentric roller on the back of the belt bracket # 3 to keep the roller in position. Use a 5/32” Allen key and 1/2” open-end wrench. Secure the clutch assembly. IMPORTANT: A minimum 1/4” space is required between the roller and the inside of the clutch Cam #8. 1/4" RIGHT HAND SHOWN 6 18. Install drive belt # 10 and clamp the two open ends equally in the lower belt bracket # 3, cutting is required for desired length. C/P doors need clamping in upper belt bracket # 25, as well, see Fig. 4. Move the doors from closed to open position and adjust the belt brackets so that belts are parallel to each other looking from top. 19. Tension the drive belt with the tension block # 5 so that the upper and lower sides can be Squeezed, together using moderate pressure. (A loose belt can jump teeth. An overly tightened belt is noisy.) 20. Install the motor operator unit assembly # 20. It is extremely important that the motor axle is, parallel to the drive pulley axle. Rubber pads are supplied to shim between, header Angles, and drive unit box assembly. This will reduce noise and vibration. 21. Lower the motor mounting plate to its bottom position. Install the motor belt # 19 over the motor pulley and slide the motor control box into the correct position. Hand-tighten the clamping bars. Correct the pulley alignment with a straight edge. This is the most critical part of the installation to reduce belt wear, noise and vibration. 22. Tension the motor belt # 19 by means of adjusting the wing nuts on the motor mounting plate equally. Do not over tighten the motor belt. 23. Secure the motor control box by tightening the clamps and doweling. Move the doors by hand to verify proper operation. 24. Start the electrical set up. CENTRE PARTING DCL DPM AUX DOL 7 Figure 5 KINETIC ENERGY, AND ASME A17.1 2000 FOR ELEVATOR DOOR SYSTEMS Requirement 2.13.4.2.4 of ASME A17.1 2000 stipulates that a data tag must be attached to the door operator or car crosshead. If you are in a jurisdiction that has adopted the 2000 code, you need to read and understand this requirement, and all of the related requirements. (see attached) The data tag is required to show: - The minimum closing code time for the door system that will result in average kinetic energy of less than 7.37 foot-pounds. - The minimum code closing time for the door system, when in nudging, that will result in average kinetic energy of less than 2.5 foot-pounds. The attached data tables are designed to give GAL customers the information necessary to comply with these requirements. If you use all GAL equipment, and follow GAL instructions, these sheets will give you the minimum closing code time for all of the normal door configurations, sizes, and operator models available. Notes: Code Closing Distance / Time On side opening, the code distance starts 2” from the jamb and goes to 2” from full close. (opening size – 4”) On center opening, code distance starts 1” from the jamb and goes to 1” from full close. (still opening size – 4”) Times shown are minimums for the code closing distance Average Kinetic Energy (7.37 ft lbs) This is the requirement for which the times shown on the data tables were calculated. The rotational inertia of the motor and operator is included in these calculations. GAL’s calculations include equipment rigidly connected thereto and accommodate all hangers, rollers, clutches, closers, releases, and any normal reopening devices Actual (peak) Kinetic Energy (17 ft lbs) Using GAL equipment and following GAL instructions, you will not exceed the requirement for actual (peak) KE. Nudging Kinetic Energy (2.5 ft lbs) If taking the minimum closing code time for your application and doubling it, you will have a safe time to use for the requirement under nudging. (Note – this is a very conservative time, if you want to close your door more quickly while in nudging, call GAL for an absolute minimum) Non Standard Systems A non-standard application, like three speed doors, or panels that are so heavy or light that they fall outside the range shown on the data tables, you can call GAL and we will calculate closing code time for your job. The following paragraphs are excerpted from ASME 17.1 2000. They are provided here for your convenience only. 8 2.13.4.2.4 Data Plate. A data plate conforming to 2.16.3.3 shall be attached to the power door operator or to the car crosshead and shall contain the following information: (a) minimum door closing time in seconds for the doors to travel the code zone distance as specified in 2.13.4.2.2 corresponding to the kinetic energy limits specified in 2.13.4.2.1(b)(2); (b) minimum door closing time in seconds for the doors to travel the Code zone distance as specified in 2.13.4.2.2 corresponding to the kinetic energy limits specified in 2.13.4.2.1(c)(2), if applicable [see 2.27.3.1.6(e)]; (c) where heavier hoistway doors are used at certain floors, the minimum door closing time in seconds corresponding to the kinetic energy limits specified in 2.13.4.2.1(b)(2) and 2.13.4.2.1(c)(2), if applicable, for the corresponding floors shall be included on the data plate. 2.13.4.2.1 Kinetic Energy… (a) Where the hoistway door and the car door/gate are closed in such a manner that stopping either one manually will stop both, the kinetic energy of the closing door system shall be based upon the sum of the hoistway and the car door weights, as well as all parts rigidly connected thereto, including the rotational inertia effects of the door operator and the connecting transmission to the door panels. (b)Where a reopening device conforming to 2.13.5 is used, the closing door system shall conform to the following requirements. (1) The kinetic energy computed for the actual closing speed at any point in the Code zone distance defined by 2.13.4.2.2 shall not exceed 23 J (17 ft-lbf); and (2) The kinetic energy computed for the average closing speed as determined in accordance with 2.13.4.2.2 shall not exceed 10 J (7.37 ft-lbf). (c) Where a reopening device is not used, or has been rendered inoperative (see 2.13.5), the closing door system shall conform to the following requirements: (1) The kinetic energy computed for the actual closing speed at any point in the code zone distance defined by 2.13.4.2.2 shall not exceed 8 J (6 ft-lbf). (2) The kinetic energy computed for the average closing speed within the code zone distance (see 2.13.4.2.2), or in any exposed opening width, including the last increment of door travel, shall not exceed 3.5 J (2.5 ft-lbf). The following tables show the minimum closing code time for MOVFE2500 doors: NOTE: The term “Door Weight” in the tables refers to the combined weight of all doors, including all car door (s) and all hoistway door(s) (of one floor only). Also, note that if the weight of the hoistway door(s) varies by floor, different settings of the code distance closing time must be used from the table. 9 MINIMUM CLOSING TIME FOR SINGLE SPEED S/O DOOR Heavy Duty Linear Operator SINGLE SPEED SLIDING DOOR 39 39 39 39 39 39 39 39 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.89 1.96 2.02 2.08 2.14 2.20 2.25 2.31 3.24 3.35 3.45 3.56 3.66 3.75 3.85 3.94 32" 225 250 275 300 325 350 375 400 39 39 39 39 39 39 39 39 28 28 28 28 28 28 28 28 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.04 2.11 2.17 2.24 2.30 2.36 2.42 2.48 3.48 3.60 3.72 3.83 3.94 4.04 4.14 4.24 34" 250 275 300 325 350 375 400 425 39 39 39 39 39 39 39 39 30 30 30 30 30 30 30 30 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.26 2.33 2.40 2.47 2.53 2.60 2.66 2.72 3.86 3.98 4.10 4.22 4.33 4.44 4.55 4.65 36" 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 32 32 32 32 32 32 32 32 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.48 2.56 2.63 2.70 2.77 2.84 2.90 2.97 4.25 4.38 4.50 4.62 4.74 4.85 4.96 5.07 38" 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 34 34 34 34 34 34 34 34 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.64 2.72 2.80 2.87 2.94 3.01 3.08 3.15 4.51 4.65 4.78 4.91 5.03 5.15 5.27 5.39 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 36 36 36 36 36 36 36 36 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.80 2.88 2.96 3.04 3.12 3.19 3.27 3.34 4.78 4.92 5.06 5.20 5.33 5.46 5.58 5.71 Door Weight (lbs) Equipment Weight (lbs) Code Distance (Inch) 42" 30" 225 250 275 300 325 350 375 400 Minimum Code Time (seconds) DOOR WIDTH (Inch) 325 350 375 400 425 450 475 500 39 39 39 39 39 39 39 39 38 38 38 38 38 38 38 38 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.12 3.21 3.29 3.37 3.45 3.52 3.60 3.67 5.34 5.49 5.63 5.76 5.89 6.02 6.15 6.27 44" Code Distance (Inch) 325 350 375 400 425 450 475 500 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.29 3.38 3.46 3.55 3.63 3.71 3.79 3.86 5.62 5.77 5.92 6.06 6.20 6.34 6.47 6.60 46" Equipment Weight (lbs) 350 375 400 425 450 475 500 525 39 39 39 39 39 39 39 39 42 42 42 42 42 42 42 42 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.55 3.64 3.72 3.81 3.89 3.98 4.06 4.13 6.06 6.22 6.37 6.51 6.66 6.80 6.94 7.07 48" Door Weight (lbs) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) Average Kinetic Energy (ft-lbs) 375 400 425 450 475 500 525 550 39 39 39 39 39 39 39 39 44 44 44 44 44 44 44 44 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.81 3.90 3.99 4.08 4.16 4.25 4.33 4.41 6.51 6.67 6.82 6.97 7.12 7.27 7.41 7.55 50" DOOR WIDTH (Inch) Average Kinetic Energy (ft-lbs) 40" Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 375 400 425 450 475 500 525 550 39 39 39 39 39 39 39 39 46 46 46 46 46 46 46 46 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.98 4.08 4.17 4.26 4.35 4.44 4.53 4.61 6.81 6.97 7.13 7.29 7.44 7.60 7.74 7.89 52" SINGLE SPEED SLIDING DOOR 400 425 450 475 500 525 550 600 39 39 39 39 39 39 39 39 48 48 48 48 48 48 48 48 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 4.26 4.35 4.45 4.54 4.63 4.73 4.81 4.99 7.28 7.44 7.61 7.77 7.93 8.08 8.23 8.53 10 MINIMUM CLOSING TIME FOR TWO SPEED S/O DOOR Heavy Duty Linear Operator 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.69 1.73 1.78 1.82 1.86 1.90 1.94 1.98 32" 225 250 275 300 325 350 375 400 50 50 50 50 50 50 50 50 28 28 28 28 28 28 28 28 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.82 1.87 1.92 1.96 2.01 2.05 2.09 2.14 3.11 3.19 3.28 3.35 3.43 3.51 3.58 3.65 34" 250 275 300 325 350 375 400 425 50 50 50 50 50 50 50 50 30 30 30 30 30 30 30 30 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.00 2.05 2.10 2.15 2.20 2.24 2.29 2.33 3.42 3.51 3.59 3.68 3.76 3.84 3.92 3.99 36" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 32 32 32 32 32 32 32 32 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.19 2.24 2.29 2.34 2.39 2.44 2.49 2.54 3.74 3.83 3.92 4.01 4.09 4.18 4.26 4.34 38" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 34 34 34 34 34 34 34 34 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.33 2.38 2.44 2.49 2.54 2.59 2.65 2.69 3.98 4.07 4.17 4.26 4.35 4.44 4.52 4.61 40" 300 325 350 375 400 425 450 475 50 50 50 50 50 50 50 50 36 36 36 36 36 36 36 36 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.52 2.58 2.64 2.69 2.75 2.80 2.85 2.90 4.31 4.41 4.51 4.60 4.70 4.79 4.88 4.97 42" 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 38 38 38 38 38 38 38 38 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.72 2.78 2.84 2.90 2.96 3.01 3.07 3.12 4.66 4.76 4.86 4.96 5.06 5.15 5.24 5.33 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 40 40 40 40 40 40 40 40 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.87 2.93 2.99 3.05 3.11 3.17 3.23 3.28 4.90 5.01 5.12 5.22 5.32 5.42 5.52 5.62 46" 50 50 50 50 50 50 50 50 Minimum Code Time (seconds) 350 375 400 425 450 475 500 525 42 42 42 42 42 42 42 42 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.08 3.14 3.21 3.27 3.33 3.39 3.45 3.51 Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 5.26 5.37 5.48 5.59 5.69 5.80 5.90 6.00 48" 30" 225 250 275 300 325 350 375 400 Average Kinetic Energy (ft-lbs) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 44 44 44 44 44 44 44 44 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.29 3.36 3.42 3.49 3.55 3.61 3.67 3.73 5.63 5.74 5.85 5.96 6.07 6.18 6.28 6.38 50" Minimum Code Time (seconds) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 46 46 46 46 46 46 46 46 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.44 3.51 3.58 3.65 3.71 3.78 3.84 3.90 5.88 6.00 6.12 6.23 6.35 6.46 6.57 6.67 52" Average Kinetic Energy (ft-lbs) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 48 48 48 48 48 48 48 48 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.66 3.73 3.80 3.87 3.94 4.01 4.07 4.14 6.26 6.39 6.51 6.62 6.74 6.85 6.96 7.07 54" Code Distance (Inch) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.82 3.89 3.96 4.03 4.10 4.17 4.24 4.31 6.53 6.65 6.78 6.90 7.02 7.14 7.25 7.37 56" Equipment Weight (lbs) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 52 52 52 52 52 52 52 52 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.97 4.05 4.12 4.20 4.27 4.34 4.41 4.48 6.79 6.92 7.05 7.17 7.30 7.42 7.54 7.66 58" Door Weight (lbs) TWO SPEED SLIDING DOOR 425 450 475 500 525 550 575 600 50 50 50 50 50 50 50 50 54 54 54 54 54 54 54 54 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 4.20 4.28 4.36 4.43 4.51 4.58 4.65 4.72 7.18 7.32 7.45 7.58 7.71 7.83 7.96 8.08 59" DOOR WIDTH (Inch) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 2.89 2.97 3.04 3.12 3.19 3.26 3.33 3.39 44" TWO SPEED SLIDING DOOR 450 475 500 525 550 575 600 625 50 50 50 50 50 50 50 50 55 55 55 55 55 55 55 55 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 4.36 4.44 4.52 4.59 4.67 4.74 4.81 4.88 7.45 7.59 7.72 7.85 7.98 8.10 8.23 8.35 DOOR WIDTH (Inch) Door Weight (lbs) Code Equipment Distance Weight (lbs) (Inch) 50 50 50 50 50 50 50 50 11 MINIMUM CLOSING TIME FOR SINGLE SPEED C/P DOOR Heavy Duty Linear Operator SINGLE SPEED CENTER PARTING DOOR 0.96 0.99 1.02 1.05 1.08 1.11 1.14 1.16 1.64 1.70 1.75 1.80 1.85 1.90 1.94 1.99 32" 225 250 275 300 325 350 375 400 50 50 50 50 50 50 50 50 14 14 14 14 14 14 14 14 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.03 1.07 1.10 1.13 1.16 1.20 1.22 1.25 1.77 1.83 1.88 1.94 1.99 2.04 2.09 2.14 34" 250 275 300 325 350 375 400 425 50 50 50 50 50 50 50 50 15 15 15 15 15 15 15 15 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.14 1.18 1.21 1.25 1.28 1.31 1.34 1.37 1.96 2.02 2.08 2.13 2.19 2.24 2.30 2.35 36" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 16 16 16 16 16 16 16 16 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.26 1.30 1.33 1.37 1.40 1.43 1.47 1.50 2.15 2.22 2.28 2.34 2.39 2.45 2.51 2.56 38" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 17 17 17 17 17 17 17 17 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.34 1.38 1.41 1.45 1.49 1.52 1.56 1.59 2.29 2.35 2.42 2.48 2.54 2.60 2.66 2.72 40" 300 325 350 375 400 425 450 475 50 50 50 50 50 50 50 50 18 18 18 18 18 18 18 18 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.46 1.50 1.54 1.57 1.61 1.65 1.68 1.72 2.49 2.56 2.63 2.69 2.76 2.82 2.88 2.94 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 19 19 19 19 19 19 19 19 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.58 1.62 1.66 1.70 1.74 1.78 1.81 1.85 2.70 2.77 2.84 2.91 2.98 3.04 3.10 3.16 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 20 20 20 20 20 20 20 20 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.66 1.71 1.75 1.79 1.83 1.87 1.91 1.95 2.85 2.92 2.99 3.06 3.13 3.20 3.27 3.33 46" 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 350 375 400 425 450 475 500 525 50 50 50 50 50 50 50 50 21 21 21 21 21 21 21 21 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.79 1.84 1.88 1.92 1.96 2.01 2.05 2.08 3.07 3.14 3.22 3.29 3.36 3.43 3.50 3.56 48" 13 13 13 13 13 13 13 13 Door Weight (lbs) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 22 22 22 22 22 22 22 22 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.92 1.97 2.01 2.06 2.10 2.14 2.18 2.22 3.29 3.37 3.45 3.52 3.59 3.66 3.73 3.80 50" 50 50 50 50 50 50 50 50 DOOR WIDTH (Inch) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 23 23 23 23 23 23 23 23 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.01 2.06 2.11 2.15 2.20 2.24 2.28 2.32 3.44 3.52 3.60 3.68 3.76 3.83 3.90 3.98 52" 30" 225 250 275 300 325 350 375 400 Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 24 24 24 24 24 24 24 24 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.15 2.20 2.25 2.29 2.34 2.38 2.43 2.47 3.68 3.76 3.84 3.92 4.00 4.07 4.15 4.22 54" Equipment Weight (lbs) Average Kinetic Energy (ft-lbs) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.24 2.29 2.34 2.39 2.43 2.48 2.53 2.57 3.83 3.92 4.00 4.08 4.16 4.24 4.32 4.40 56" Door Weight (lbs) Code Equipment Distance Weight (lbs) per side (Inch) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.33 2.38 2.43 2.48 2.53 2.58 2.63 2.67 3.98 4.07 4.16 4.25 4.33 4.41 4.49 4.57 58" DOOR WIDTH (Inch) 42" Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 44" Average Kinetic Energy (ft-lbs) Code Distance per side (Inch) 425 450 475 500 525 550 575 600 50 50 50 50 50 50 50 50 27 27 27 27 27 27 27 27 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.47 2.53 2.58 2.63 2.68 2.73 2.78 2.83 4.23 4.32 4.41 4.50 4.58 4.67 4.75 4.83 59" SINGLE SPEED CENTER PARTING DOOR 450 475 500 525 550 575 600 625 50 50 50 50 50 50 50 50 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.57 2.63 2.68 2.73 2.78 2.83 2.88 2.93 4.40 4.49 4.58 4.67 4.75 4.84 4.92 5.00 12 MINIMUM CLOSING TIME FOR TWO SPEED C/P DOOR Heavy Duty Linear Operator 1.15 1.18 1.20 1.23 1.25 1.27 1.30 1.32 38" 275 300 325 350 375 400 425 450 84 84 84 84 84 84 84 84 17 17 17 17 17 17 17 17 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.22 1.25 1.28 1.30 1.33 1.35 1.38 1.40 2.09 2.14 2.18 2.23 2.27 2.31 2.35 2.39 40" 300 325 350 375 400 425 450 475 84 84 84 84 84 84 84 84 18 18 18 18 18 18 18 18 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.32 1.35 1.38 1.41 1.43 1.46 1.48 1.51 2.26 2.31 2.36 2.40 2.45 2.49 2.53 2.58 42" 325 350 375 400 425 450 475 500 84 84 84 84 84 84 84 84 19 19 19 19 19 19 19 19 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.43 1.46 1.48 1.51 1.54 1.56 1.59 1.62 2.44 2.49 2.54 2.58 2.63 2.68 2.72 2.76 44" 325 350 375 400 425 450 475 500 84 84 84 84 84 84 84 84 20 20 20 20 20 20 20 20 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.50 1.53 1.56 1.59 1.62 1.65 1.67 1.70 2.57 2.62 2.67 2.72 2.77 2.82 2.86 2.91 46" 350 375 400 425 450 475 500 525 84 84 84 84 84 84 84 84 21 21 21 21 21 21 21 21 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.61 1.64 1.67 1.70 1.73 1.76 1.79 1.81 2.75 2.80 2.86 2.91 2.96 3.01 3.05 3.10 375 400 425 450 475 500 525 550 84 84 84 84 84 84 84 84 22 22 22 22 22 22 22 22 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.72 1.75 1.78 1.81 1.84 1.87 1.90 1.93 2.94 2.99 3.04 3.10 3.15 3.20 3.25 3.30 50" 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 Door Weight (lbs) 375 400 425 450 475 500 525 550 84 84 84 84 84 84 84 84 23 23 23 23 23 23 23 23 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.80 1.83 1.86 1.89 1.93 1.96 1.99 2.02 52" 16 16 16 16 16 16 16 16 DOOR WIDTH (Inch) 400 425 450 475 500 525 550 575 84 84 84 84 84 84 84 84 24 24 24 24 24 24 24 24 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.91 1.94 1.98 2.01 2.04 2.07 2.11 2.14 3.26 3.32 3.38 3.44 3.49 3.55 3.60 3.65 54" 84 84 84 84 84 84 84 84 Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 3.07 3.13 3.18 3.24 3.29 3.35 3.40 3.45 425 450 475 500 525 550 575 600 84 84 84 84 84 84 84 84 25 25 25 25 25 25 25 25 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.02 2.06 2.09 2.13 2.16 2.19 2.23 2.26 3.46 3.52 3.58 3.64 3.69 3.75 3.81 3.86 56" 36" 275 300 325 350 375 400 425 450 Average Kinetic Energy (ft-lbs) 425 450 475 500 525 550 575 600 84 84 84 84 84 84 84 84 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.10 2.14 2.18 2.21 2.25 2.28 2.31 2.35 3.60 3.66 3.72 3.78 3.84 3.90 3.96 4.01 58" Door Weight (lbs) Code Equipment Distance Weight per side (lbs) (Inch) TWO SPEED CENTER PARTING DOOR 450 475 500 525 550 575 600 625 84 84 84 84 84 84 84 84 27 27 27 27 27 27 27 27 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.22 2.26 2.30 2.33 2.37 2.40 2.44 2.47 3.80 3.87 3.93 3.99 4.05 4.11 4.17 4.23 59" DOOR WIDTH (Inch) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 1.97 2.01 2.05 2.10 2.14 2.18 2.21 2.25 48" TWO SPEED CENTER PARTING DOOR 450 475 500 525 550 575 600 625 84 84 84 84 84 84 84 84 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.26 2.30 2.34 2.38 2.41 2.45 2.48 2.52 3.87 3.94 4.00 4.06 4.13 4.19 4.25 4.31 Code Equipment Distance Weight per side (lbs) (Inch) Average Kinetic Energy (ft-lbs) Minimum Code Time (seconds) 13 MINIMUM CLOSING TIME FOR SINGLE SPEED S/O DOOR Light Duty Geared Linear Operator 1.67 1.74 1.81 1.88 1.94 2.00 2.06 2.12 2.85 2.97 3.09 3.21 3.32 3.43 3.53 3.63 32" 225 250 275 300 325 350 375 400 39 39 39 39 39 39 39 39 28 28 28 28 28 28 28 28 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.80 1.87 1.95 2.02 2.09 2.16 2.22 2.29 3.07 3.20 3.33 3.46 3.58 3.69 3.80 3.91 34" 250 275 300 325 350 375 400 425 39 39 39 39 39 39 39 39 30 30 30 30 30 30 30 30 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.01 2.09 2.17 2.24 2.31 2.38 2.45 2.52 3.43 3.57 3.70 3.83 3.95 4.07 4.19 4.30 36" 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 32 32 32 32 32 32 32 32 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.23 2.31 2.39 2.47 2.54 2.61 2.68 2.75 3.81 3.95 4.09 4.22 4.35 4.47 4.59 4.71 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 34 34 34 34 34 34 34 34 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.37 2.45 2.54 2.62 2.70 2.78 2.85 2.93 4.05 4.20 4.34 4.48 4.62 4.75 4.88 5.00 275 300 325 350 375 400 425 450 39 39 39 39 39 39 39 39 36 36 36 36 36 36 36 36 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.51 2.60 2.69 2.77 2.86 2.94 3.02 3.10 4.28 4.44 4.60 4.75 4.89 5.03 5.17 5.30 Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 42" 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 Minimum Code Time (seconds) 325 350 375 400 425 450 475 500 38 38 38 38 38 38 38 38 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.84 2.93 3.02 3.10 3.19 3.27 3.35 3.43 4.85 5.01 5.16 5.31 5.45 5.59 5.73 5.86 44" 26 26 26 26 26 26 26 26 39 39 39 39 39 39 39 39 Average Kinetic Energy (ft-lbs) 325 350 375 400 425 450 475 500 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.99 3.08 3.18 3.27 3.36 3.44 3.53 3.61 5.11 5.27 5.43 5.59 5.74 5.89 6.03 6.17 46" 30" 225 250 275 300 325 350 375 400 Equipment Code Weight Distance (lbs) (Inch) 350 375 400 425 450 475 500 525 39 39 39 39 39 39 39 39 42 42 42 42 42 42 42 42 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.24 3.34 3.43 3.52 3.61 3.70 3.79 3.87 5.54 5.70 5.87 6.03 6.18 6.33 6.48 6.62 48" Minimum Code Time When Door Protection Disabled (Nudging) (seconds) Door Weight (lbs) 375 400 425 450 475 500 525 550 39 39 39 39 39 39 39 39 44 44 44 44 44 44 44 44 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.49 3.59 3.69 3.79 3.88 3.97 4.06 4.14 5.98 6.15 6.31 6.47 6.63 6.79 6.94 7.09 50" Minimum Code Time (seconds) DOOR WIDTH (Inch) 375 400 425 450 475 500 525 550 39 39 39 39 39 39 39 39 46 46 46 46 46 46 46 46 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.65 3.76 3.86 3.96 4.06 4.15 4.24 4.33 6.25 6.43 6.60 6.77 6.93 7.10 7.25 7.41 52" Average Kinetic Energy (ft-lbs) 38" SINGLE SPEED SLIDING DOOR 40" SINGLE SPEED SLIDING DOOR 400 425 450 475 500 525 550 600 39 39 39 39 39 39 39 39 48 48 48 48 48 48 48 48 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 3.92 4.03 4.13 4.23 4.33 4.43 4.52 4.70 6.71 6.89 7.06 7.24 7.40 7.57 7.73 8.04 DOOR WIDTH (Inch) Door Weight (lbs) Equipment Code Weight Distance (lbs) (Inch) 39 39 39 39 39 39 39 39 14 MINIMUM CLOSING TIME FOR SINGLE SPEED C/P DOOR Light Duty Geared Linear Operator SINGLE SPEED CENTER PARTING DOOR 1.42 1.48 1.54 1.60 1.66 1.71 1.76 1.81 32" 225 250 275 300 325 350 375 400 50 50 50 50 50 50 50 50 14 14 14 14 14 14 14 14 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 0.90 0.93 0.97 1.01 1.04 1.08 1.11 1.14 1.53 1.60 1.66 1.72 1.78 1.84 1.90 1.95 34" 250 275 300 325 350 375 400 425 50 50 50 50 50 50 50 50 15 15 15 15 15 15 15 15 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.00 1.04 1.08 1.12 1.15 1.19 1.22 1.26 1.71 1.78 1.85 1.91 1.97 2.03 2.09 2.15 36" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 16 16 16 16 16 16 16 16 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.11 1.15 1.19 1.23 1.27 1.30 1.34 1.37 1.90 1.97 2.04 2.10 2.17 2.23 2.29 2.35 38" 275 300 325 350 375 400 425 450 50 50 50 50 50 50 50 50 17 17 17 17 17 17 17 17 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.18 1.22 1.27 1.31 1.35 1.39 1.42 1.46 2.02 2.09 2.17 2.24 2.30 2.37 2.44 2.50 40" 300 325 350 375 400 425 450 475 50 50 50 50 50 50 50 50 18 18 18 18 18 18 18 18 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.30 1.34 1.38 1.43 1.47 1.51 1.55 1.58 2.22 2.29 2.37 2.44 2.51 2.58 2.64 2.71 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 19 19 19 19 19 19 19 19 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.42 1.46 1.51 1.55 1.59 1.63 1.67 1.71 2.42 2.50 2.58 2.65 2.72 2.79 2.86 2.93 325 350 375 400 425 450 475 500 50 50 50 50 50 50 50 50 20 20 20 20 20 20 20 20 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.49 1.54 1.59 1.63 1.68 1.72 1.76 1.80 2.55 2.63 2.71 2.79 2.86 2.94 3.01 3.08 46" 0.83 0.87 0.90 0.94 0.97 1.00 1.03 1.06 350 375 400 425 450 475 500 525 50 50 50 50 50 50 50 50 21 21 21 21 21 21 21 21 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.62 1.66 1.71 1.76 1.80 1.85 1.89 1.93 2.76 2.85 2.93 3.01 3.09 3.16 3.23 3.31 48" 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 Equipment Weight (lbs) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 22 22 22 22 22 22 22 22 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.74 1.79 1.84 1.89 1.94 1.98 2.03 2.07 2.98 3.07 3.15 3.23 3.31 3.39 3.46 3.54 50" 13 13 13 13 13 13 13 13 Door Weight (lbs) 375 400 425 450 475 500 525 550 50 50 50 50 50 50 50 50 23 23 23 23 23 23 23 23 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.82 1.88 1.93 1.98 2.02 2.07 2.12 2.16 3.12 3.21 3.29 3.38 3.46 3.54 3.62 3.70 52" 50 50 50 50 50 50 50 50 DOOR WIDTH (Inch) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 24 24 24 24 24 24 24 24 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.96 2.01 2.06 2.11 2.16 2.21 2.26 2.30 3.35 3.44 3.53 3.61 3.70 3.78 3.86 3.94 54" 30" 225 250 275 300 325 350 375 400 Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.04 2.09 2.15 2.20 2.25 2.30 2.35 2.40 3.49 3.58 3.67 3.76 3.85 3.94 4.02 4.10 56" Equipment Weight (lbs) Average Kinetic Energy (ft-lbs) Code Distance per side (Inch) 400 425 450 475 500 525 550 575 50 50 50 50 50 50 50 50 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.12 2.18 2.23 2.29 2.34 2.39 2.45 2.50 3.63 3.72 3.82 3.91 4.01 4.09 4.18 4.27 58" Door Weight (lbs) 42" Minimum Code Time (seconds) DOOR WIDTH (Inch) Code Distance per side (Inch) 44" Average Kinetic Energy (ft-lbs) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 425 450 475 500 525 550 575 600 50 50 50 50 50 50 50 50 27 27 27 27 27 27 27 27 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.26 2.32 2.38 2.43 2.49 2.54 2.59 2.64 3.87 3.97 4.06 4.16 4.25 4.34 4.43 4.52 59" SINGLE SPEED CENTER PARTING DOOR 450 475 500 525 550 575 600 625 50 50 50 50 50 50 50 50 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.36 2.42 2.48 2.53 2.59 2.64 2.69 2.74 4.04 4.14 4.24 4.33 4.42 4.51 4.60 4.69 16 MINIMUM CLOSING TIME FOR TWO SPEED C/P DOOR Light Duty Geared Linear Operator Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 36" 275 300 325 350 375 400 425 450 84 84 84 84 84 84 84 84 16 16 16 16 16 16 16 16 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 0.99 1.02 1.05 1.07 1.10 1.13 1.15 1.18 1.69 1.74 1.79 1.83 1.88 1.93 1.97 2.01 38" 275 300 325 350 375 400 425 450 84 84 84 84 84 84 84 84 17 17 17 17 17 17 17 17 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.05 1.08 1.11 1.14 1.17 1.20 1.22 1.25 1.79 1.85 1.90 1.95 2.00 2.05 2.09 2.14 40" 300 325 350 375 400 425 450 475 84 84 84 84 84 84 84 84 18 18 18 18 18 18 18 18 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.14 1.18 1.21 1.24 1.27 1.30 1.32 1.35 1.96 2.01 2.06 2.12 2.17 2.22 2.26 2.31 42" 325 350 375 400 425 450 475 500 84 84 84 84 84 84 84 84 19 19 19 19 19 19 19 19 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.24 1.27 1.31 1.34 1.37 1.40 1.43 1.46 2.12 2.18 2.23 2.29 2.34 2.39 2.44 2.49 44" 325 350 375 400 425 450 475 500 84 84 84 84 84 84 84 84 20 20 20 20 20 20 20 20 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.31 1.34 1.37 1.41 1.44 1.47 1.50 1.53 2.23 2.29 2.35 2.41 2.46 2.52 2.57 2.62 350 375 400 425 450 475 500 525 84 84 84 84 84 84 84 84 21 21 21 21 21 21 21 21 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.41 1.44 1.48 1.51 1.54 1.58 1.61 1.64 2.41 2.47 2.53 2.58 2.64 2.70 2.75 2.80 375 400 425 450 475 500 525 550 84 84 84 84 84 84 84 84 22 22 22 22 22 22 22 22 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.51 1.55 1.58 1.62 1.65 1.69 1.72 1.75 2.59 2.65 2.71 2.77 2.82 2.88 2.94 2.99 DOOR WIDTH (Inch) Door Weight (lbs) Equipment Weight (lbs) Code Distance per side (Inch) Average Kinetic Energy (ft-lbs) Minimum Code Time (seconds) Minimum Code Time When Door Protection Disabled (Nudging) (seconds) 50" Minimum Code Time (seconds) 375 400 425 450 475 500 525 550 84 84 84 84 84 84 84 84 23 23 23 23 23 23 23 23 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.58 1.62 1.66 1.69 1.73 1.76 1.80 1.83 2.70 2.77 2.83 2.89 2.95 3.01 3.07 3.13 52" Average Kinetic Energy (ft-lbs) 400 425 450 475 500 525 550 575 84 84 84 84 84 84 84 84 24 24 24 24 24 24 24 24 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.69 1.73 1.77 1.80 1.84 1.87 1.91 1.94 2.89 2.95 3.02 3.08 3.14 3.20 3.26 3.32 54" Code Distance per side (Inch) 425 450 475 500 525 550 575 600 84 84 84 84 84 84 84 84 25 25 25 25 25 25 25 25 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.80 1.84 1.88 1.91 1.95 1.99 2.02 2.06 3.08 3.14 3.21 3.27 3.34 3.40 3.46 3.52 56" Equipment Weight (lbs) 425 450 475 500 525 550 575 600 84 84 84 84 84 84 84 84 26 26 26 26 26 26 26 26 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.87 1.91 1.95 1.99 2.03 2.07 2.10 2.14 3.20 3.27 3.34 3.41 3.47 3.54 3.60 3.66 58" Door Weight (lbs) 450 475 500 525 550 575 600 625 84 84 84 84 84 84 84 84 27 27 27 27 27 27 27 27 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 1.99 2.03 2.07 2.11 2.15 2.19 2.22 2.26 3.40 3.47 3.54 3.60 3.67 3.74 3.80 3.87 59" DOOR WIDTH (Inch) 46" TWO SPEED CENTER PARTING DOOR 48" TWO SPEED CENTER PARTING DOOR 450 475 500 525 550 575 600 625 84 84 84 84 84 84 84 84 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 7.37 7.37 7.37 7.37 7.37 7.37 7.37 7.37 2.02 2.06 2.11 2.15 2.19 2.23 2.26 2.30 3.46 3.53 3.60 3.67 3.74 3.81 3.87 3.94 17 PARTS LIST The following parts can be purchased from GAL Note: GAL reserves the right to replace any items in this list at any time without notice. Description 1 SINGLE SIDE SLIDE UNIVERSAL PLATE (RH, LH) 2000-1031-R 2000-1031-L 2 SINGLE SIDE SLIDE EXTENSION ARM (18”, 30”, 39”) 2000-1037-A 2000-1038-A 2000-1039-A 3 LOWER BELT BRACKET KEEPER ASSEMBLY R.H.SHOWN Picture GAL Par No. Item 2500-3068- L L.H. 2500-3068-R RH. 4 TAKE-UP PULLEY ASSEMBLY 2500-3075 5 LINEAR BELT TENSION BLOCK ASSEMBLY 2500-3080 18 6 GATE SWITCH ASSEMBLY 7 LEFT HAND SHOWN KEEPER BRACKET ASSEMBLY SW1-0001N 2500-3092-L L.H. 2500-3092-R R.H. 8 CLUTCH CAM ASSEMBLY 2500-3084 9 FIXING STRUT OPEN DOOR STOP 2500-3088 19 10 2-SPEED SIDE SLIDE OPEN-CLOSED DOOR STOP 2500-3089 11 LINEAR DRIVE BELT 2500-5009 12 GATE SWITCH ROLLER SW1-0007N 13 CLUTCH LINKAGE ARM ASSEMBLY 2000-3085 14 DCL & DOL SENSOR BLOCK ASSEMBLY 2500-5019 15 2-SPEED UNIVERSAL BRACKET SIDE SLIDE 2000-1040-2S 16 TRACK SHIM HH1-0032N 20 17 DOOR SHEAVE ASSEMBLY INQUIRE WITH GAL/ECI FOR APROPRIATE SHEAVES FOR YOUR APPLICATION 18 HEADER ANGLESSL/CP 909-SERIES 19 FIXING STRUT 2000-3066 (SSL) 2000-3067 (2 SP) 20 DRIVE PULLEY ASSEMBLY 2500-3074 2500-2075-1(8') 21 MULTI “V” MOTOR BELT 2500-2075-2 (8'-6") 2500-2075-3 ( 9') 2500-2075-4 ( 9'-6") 2500-2075-5 (10') 21 22 ½ HP 3-PH MOTOR ASSEMBLY + PIVOT AND BASE PLATE 2500-3059 23 KEEPER CLUTCH ASSEMBLY 892-5008 & 892-2007 TRACK INQUIRE WITH GAL/ECI FOR APROPRIATE APLLICATION 24 22 25 COMPLETE DRIVE UNIT BOX ASSEMBLY 2500-3054 26 UNIVERSAL PLATE-CP 2000-1040-D-4 27 EXTENSION ARMCP (10”, 14”) 2000-1041-A 2000-1042-A 28 UPPER BELT BRACKET USE ON C/P ONLY 2000-3069 23 29 30 MOVFE2500 GEARED MOTOR MOUNTING HEAVY DUTY LINEAR BELT PULLEY 2500-5024 2500-1012 31 GEARED MOTOR ASSEMBLY – LEFT HAND 2500-3072-L 32 GEARED MOTOR ASSEMBLY – RIGHT HAND 2500-3072-R 24 NOTES Copyright © 2013 GAL All rights reserved. No part of this document may be reproduced in any form,machine or natural without the express written consent of GAL. Canada 25 26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 29 Page Layout : OneColumn Page Mode : UseNone Creator : Online2PDF.com Producer : Online2PDF.com Create Date : 2017:07:04 15:12:24EXIF Metadata provided by EXIF.tools