K 1200 Technical Practice Viking 1200/K EWP Multi Button Handsfree Entry Phone Tech Info
User Manual: Viking K-1200/K-1200-EWP Multi Button Handsfree Entry Phone Tech Info VIKING Apartment Entry Systems
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
TECHNICAL Practice K-1200 K-1200-EWP Multi-Button Handsfree Entry Phone Practice TELECOM SOLUTIONS FOR THE 2 1 S T C E N T U RY October 7, 2009 12 Button Apartment Entry Phone with Built-In Door Strike Relay The K-1200 Entry Phone is a two-way, handsfree telephone with 12 buttons for calling individual residences in an apartment building. The rugged stainless steel faceplate has a printed directory housed in a waterproof, scratch-resistant lens. Each button is beside the tenants name in the directory so there are no confusing codes to deal with. Calling a particular tenant is as easy as pressing a single button. The K-1200 has a built in speed dialer that can handle up to 12 primary phone numbers, each with 22 digits. If there is no answer at the first number, a second number can be called automatically. Once the tenant answers their phone, a single touch tone command can activate the door strike relay. For “no phone line” applications, the K1200 is compatible with the C-3000 no CO (phone line) controller. Model K-1200 (shown in optional VE-5x10-SS, not included) For outdoor applications, the K-1200 is available with Enhanced Weather Protection. EWP products feature rubber gaskets and boots, closed cell foam gasketing, silicone sealed connections, anticorrosive gel filled butt connectors, as well as urethane encapsulated circuit boards with internally sealed trim POTS and DIP switches. Features Applications • • • • • • Small apartment buildings • Professional buildings • Gated communities • • • • • • • • Operates on 12 to 24 volts AC/DC 12 speed dial buttons (22 digits each) 12 alternate number positions (22 digits each) One button operation (no call button) Hang-up on CPC, busy, silence, time-out or dial tone return Touch tone restriction from microphone Integral relays for camera control and door strike Works with C-1000B for increased security Works with C-3000 for “No CO” (phone line) operation Optional Enhanced Weather Protection (EWP) 50 keyless entry codes See model K-1205 for integral camera Postal lock input w w w. v i k i n g e l e c t r o n i c s . c o m Phone...715.386.8861 info@vikingelectronics.com Specifications Power: 12 to 24 Volts AC or DC, 12VDC adapter provided Note: To assure operation during a power outage, a UPS should be used. Dimensions: 127mm x 254mm x 63.5mm (5" x 10" x 2.5") Shipping weight: 2.2 kg (4.8 lbs.) Operating Temp: -35°C to 66°C (-30°F to 150°F) Relay Contact Rating: Door Strike: 5A @ 30VDC/250VAC Maximum Camera: 0.5A @ 125 VAC, 1.0A @ 30VDC Connections: (8) gel-filled butt connectors (3M Scotchlok UR2) IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666 Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday through Friday 8am - 5pm central time. So that we can give you better service, before you call please: 1. Know the model number, the serial number and what software version you have (see serial label). 2. Have your Technical Practice in front of you. 3. It is best if you are on site. RETURNING PRODUCT FOR REPAIR RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that needs repair: 1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc. 2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial St, Hudson, WI 54016 3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box. 4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned. The following procedure is for equipment that has failed out-of-box (within 10 days of purchase): 1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis. 2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue. 3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same R.A. number. 4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge. LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER. EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH. FCC REQUIREMENTS This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the side of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The REN is used to determine the number of devices that may be connected to a telephone line. Excessive REN's on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of the REN's should not exceed five (5.0) To be certain of the number of devices that may be connected to a line, as determined by the total REN's, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this K-1200 does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. If the K-1200 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications to maintain uninterrupted service. If trouble is experienced with the K-1200, for repair or warranty information, please contact: Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666 If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. Connection to Party Line Service is subject to State Tariffs. Contact the state public utility commission, public service commission or corporation commission for information. WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS: Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours, such as early morning or late evenings. It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges. PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Installation A. Mounting The K-1200 is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor applications use the K-1200-EWP. The K-1200 can either be installed as a flush mount unit using the included rough in box, or as a surface mount unit using an optional VE-5x10. The rough in box uses the inner set of four holes on the face plate while the VE-5x10 uses the outside set of holes. A set of dummy screws and nuts are provided to fill the unused mounting holes. 5.00" 4.50" 2.596" 0.952" 10.0" 1 9.5" 2 Side View of the K-1200 Zinc-Plated Steel Rough-In Box (included) 4.5" Optional VE-5x10 Surface Mount Box (not included) 2.5" 5.22" 3.69" 0.425" 8.65" (8) #6-32 x 3/4" Stainless Steel Hexdrive Screws (included) - or 9.12" 10.14" 3 4 5 6 7 8 9 0 *# VIKING © Front View of the K-1200 2 ! IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876. B. Changing the Directory Paper Directory To install a directory, remove the four screws that mount the directory lens to the front of the K-1200 using the included Allen wrench. Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the names with the front panel graphics. For your convenience, the back of this document has pre-printed directory forms. Directory Lens C. Wiring The K-1200 can be powered from any source supplying 12 to 24 volts, AC or DC. A 12 volt DC adapter is supplied with the product. When using the included adapter, the plug on the adapter cord will have to be removed. The power connections to the K-1200 (black wires) are not polarity sensitive. Color Function Black Power In Black Power In Green Phone Line In There are also 8 more wires connected to the K-1200 controller board. Two wires are for the incoming phone line, three are from the high current door strike relay and the last three are from the camera relay. Gel filled butt connectors are provided for easier connection to building wiring. The table at the right describes each wire’s function. Red Phone Line In Brown Door Strike Relay common Orange Door Strike Relay NC Yellow Door Strike Relay NO Blue Camera Relay common Violet Camera Relay NC White Camera Relay NO Applications Important: To operate the K-1200 during a power failure, a UPS should be installed. A. Connecting a Doorstrike to the K-1200 Internal Relay The K-1200 provides a dry contact output that can be used for operation of a door strike. To use this feature, the Door Strike Code and Door Strike Time must be set in programming. In this mode, when the Door Strike Code is detected, the K-1200 will energize the relay for the period of time selected in the Door Strike Time (see Programming section E and F). If a Postal Lock is required, connect the normally open contacts of the lock to the two white wires coming from the two pin connector on the lower portion of the control board. When the postal lock is momentarily actuated, the door strike will energize for the programmed Door Strike Time. * Note: To prevent unwanted radio interference, route the connecting wires through the included ferrite core. ** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating. 120V AC Black Black Q171360 120V AC 100 W 0.5W Red * Ferrite Core (included) CO Line Green Brown (COM) Doorstrike/Magnetic Lock Yellow (N.O.) VIKING Orange (N.C.) Model: K-1200 P/N: 260878-1 DEV: S/N: XXXXXX White Viking Electronics, Inc. (715)386-8861 1531 Industrial St., Hudson, WI 54016 White Rear View of the K-1200 Postal Lock Switch (N.O.) ** Gel-Filled Butt Connectors (included) 3 B. Connecting Camera Control to the K-1200 Internal Relay Another internal relay in the K-1200 can be used to trigger a camera controller. When the K-1200 makes a call, it will energize the relay and hold it on until the call is done. * Note: To prevent unwanted radio interference, route the connecting wires through the included ferrite core. ** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating. 120V AC Black Black Q171360 100 W 0.5W Red CO Line * Ferrite Core (included) Green Blue (COM) Camera Controller Violet (NC) (not included) or VIKING White (NO) Model: K-1200 P/N: 260878-1 DEV: S/N: XXXXXX Viking Electronics, Inc. (715)386-8861 1531 Industrial St., Hudson, WI 54016 ** Gel-Filled Butt Connectors (included) Rear View of the K-1200 C. Using the K-1200 with a C-1000B In some instances it may be a concern that the Door Strike relay is outside the door. In this situation, a second controller such as a C-1000B can be used. Be sure to disable the door strike code for the K-1200 (see Programming section H). Notes: 1. The C-1000B must be in the “Analog Station Mode” (refer to the C-1000B Technical Practice). 2. The K1200 keyless entry codes can not be used in this application. 3. The K-1200 will hang-up during doorstrike activation. Model C-1000B (not included) 120V AC VIKING © MODEL C-1000B Talk Battery Switch 2 3 4 5 COM 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 2 3 OFF ON C LED1 OUT TO PHONES ON DIP Switches ON ON N.O. N.C. - - - - AUX. CONTACT OUTPUT SIG GND SIG GND SIG GND VIDEO 1 IN VIDEO 2 IN VIDEO OUT EARTH C.O. LINE GND INPUT DOOR STRIKE 2 DOOR STRIKE 1 DOORBOX 2 DOORBOX 1 DOORBOX PWR OUTPUT KEYLESS CONTACT CLOSURE INPUT LINE OUT TO PHONES EARTH GND 1 OFF DOOR ENTRY / CCTV VIDEO CONTROLLER PHONE LINE INPUT 13.8V AC Adapter (included) PWR 13.8 VAC ELECTRONICS HUDSON, WI 54016 KEYLESS C.C. INPUT TALK OFF DOOR BOX 1 DOORBOX 13VAC PWR BATTERY ON DOOR BOX 2 1 C LED2 N.O. COM N.C. DOOR STRIKE 1 2 3 C LED3 120V AC N.O. COM N.C. DOOR STRIKE 2 Doorstrike/Magnetic Lock 2 * Earth Ground 5A@30V DC/ 250V AC maximum 120V AC CO line or Analog PABX/KSU Station 4 Red Green Model K-1200 D. Using the K-1200 with a C-3000 For a “No CO” installation, a Viking C-3000 No CO controller can be used with the K-1200. Note, the K-1200 will need to be programmed on a separate CO line or use the Viking DLE-200B. The door strike can be controlled by the K-1200 or the internal relay on the C-3000, just be sure to disable the door strike feature in the other unit. The keyless entry feature of the C-3000 can not be used. If not using keyless entry codes, use the C-3000 to control the doorstrike. If using keyless entry codes (up to 50), use the K1200 to control the doorstrike. The K-1200 speed dial position should be programmed with the C-3000 line selection command “1” to “12”. (Refer to the C-3000 Technical Practice for more details). VIKING © MODEL C-3000 Model C-3000 (not included) VIKING ELECTRONICS HUDSON, WI 54016 120V AC 12 UNIT APARTMENT ENTRY CONTROLLER MODULE POWER 13.8 VAC POSTAL LOCK INPUT DIP SWITCH 1 2 3 DOOR STRIKE 1 120V AC DOOR STRIKE 2 RJ21X 12 APARTMENT LINES IN/OUT 1 2 3 4 5 6 7 8 O N MULTI-MODULE INTERCONNECTS O F F PWR IN USE PROGRAM PHONE Model K-1200 ENTRY PHONE 1 ENTRY PHONE 2 OUT IN Red Green Green Red Model K-1200 Notes: 1. In this application, the C-3000 keyless entry feature is not available. Use the keyless entry feature of the K1200 and wire both door strike relays in parallel. 2. The K-1200 will hang-up during the doorstrike activation. Programming A. Accessing The Programming Mode The K-1200 Entry Controller can be programmed from any Touch Tone phone using a C.O. line, analog PABX/KSU, or a DLE-200B Line Simulator. 1. Accessing the Programming Mode with the Security Code Step 1. Move DIP switch 1 to the ON position (sets unit to answer incoming calls). Step 2. From a touch tone phone, call the line attached to the K-1200. Step 3. When the K-1200 answers, listen for the beep and then enter a “#“ followed by the 6-digit security code (factory set to 845464). A double beep should be heard indicating you have entered the programming mode. 2. Accessing the Programming Mode without the Security Code Step Step Step Step Step 1. 2. 3. 4. 5. Move DIP switch 1 to the ON position (sets unit to answer incoming calls). Move DIP switch 4 to the ON position (incoming calls enter programming without security code, see section B). From a touch tone phone call the line attached to the K-1200. When the K-1200 answers, a double beep should be heard indicating you have entered the programming mode. When finished programming, move DIP switch 4 back to the OFF position. B. Security Code (memory location #47) This six digit number can be used to access the programming mode. The security code has been factory set to 845464 (V-I-K-I-N-G). It is recommended that you change the security code to a personal 6 digit number. To change the security code, access programming (see Programming section A). Enter six digits 0-9 followed by #47. If you have forgotten your security code, follow the steps in Programming section A, 2. Accessing the Programming Mode Without the Security Code). Note: The security code must be six digits in length and can NOT contain a , or #. C. Keyless Entry Codes The K-1200 can be programmed with up to 50 keyless entry codes. This feature allows a visitor to let themselves in by entering a preprogrammed code on the K-1200 keypad. Each keyless code can contain from 1 to 6 digits and is programmed by entering the digits into any of the locations #50 to #99. To clear a location enter “#” followed by the position number without any preceding number. The “,” and “#” keys can also be used in the keyless codes by substituting “#20” and “#21” (respectively) when programming a keyless position. 5 D. Quick Programming Features The K-1200 is programmed through the incoming phone line. The programming commands are structured so that they do not interfere with the commands of a C-1000B controller. Enter Digits - then - Enter Memory Location Speed dial numbers .................................................................................................. 0-46 digits*** Door strike time in sec (factory 05, 00 =.5 sec)**........................................................ 2 digits Door strike code (factory 6, no digits disables) .......................................................... 1-2 digits Maximum call time in min (factory 3, 0 = .5 min, no digits disables)** ....................... 1 digit Maximum ring time in sec (factory 20, 00 disables)** ............................................... 2 digits Silence Time Out in sec (factory 10, 00 disables)** .................................................. 2 digits Talk/listen delay time in .1 sec (factory 2)** ............................................................... 1 digit Security code (factory 845464)** ............................................................................... 6 digits Keyless entry codes .................................................................................................. 1-6 digits Dial a (,) .................................................................................................................. #20 Dial a (#) ................................................................................................................... #21 Add a 4 second pause .............................................................................................. #22 Add a 1 second pause ............................................................................................. #23 Second phone number selector ................................................................................ #24 Normal dialing speed* .............................................................................................. #30 Fast dialing speed ..................................................................................................... #31 Hang up on dial tone enable* ................................................................................... #32 Hang up on dial tone disable .................................................................................... #33 Reset all programming to factory default settings ................................................... ### Hang up from programming ...................................................................................... ##7 then then then then then then then then then #01 - #12 #40 #41 #42 #43 #44 #45 #47 #50 - #99 *Factory settings ** Cannot contain “,“ or “#“ (see #20 and #21) *** 45 digits maximum if two numbers are programmed in one memory location Notes: 1. A single or double beep indicates a valid entry, three beeps indicate an error. 2. “,“ or “#“, pauses or second phone number selector occupy one digit of memory. E. Speed Dial Numbers The K-1200 Entry Controller can be programmed with up to twelve 46 digit numbers. Each number can also be programmed with special features such as pauses, and the Touch Tones “,” and “#”. Each of the special characters count as a single digit. Each of the speed dial positions #01 to #12 pertain to the corresponding button on the front of the K-1200. The button “0” uses position #10, the “,” uses position #11 and the “#” uses position #12. To program a speed dial position, enter programming (see section A) then enter the desired number followed by the selected position. To clear a position, only enter a “#“ followed by the position number with out any preceding number. The K-1200 also has the capability to dial a second phone number if there is no answer or busy at the first number. This can be used if the tenant wants the visitor to call their cell phone if they are not at home. To program a second number, be sure that position #43 is programmed with the desired maximum ring time, then enter the first number to be dialed, followed by “#24”. A single beep should be heard. Next enter the second number to be dialed followed by “#“ plus the memory location. The total number of digits cannot exceed 46 for each position (45 digits if two numbers are programmed). The following are examples of speed dial number entries: To Program the K-1200 to... Step 1 (see section A) Step 2 - Enter Digits ...store 555-1234 at the first button position Enter programming 5551234#01 ...store a 9, a 1 second pause, then 333-4444 in the seventh button position Enter programming 9#233334444#07 ...store a 23,# in the eight position Enter programming 23#20#21#08 ...store a first number of 22 and a second number of 33 in the “#“ button position Enter programming 22#24 (beep) 33#12 F. Door Strike Time The actual time the door strike relay is energized is controlled by location #40. The time can be set from 00 to 99 seconds, (an entry of “00” gives 0.5 seconds). In order to use this feature, be sure the relay door strike code is set (see section H). G. Maximum Call Time In some installations, it maybe desirable to limit the length of the call to the tenant. This can be done by programming position #42. The maximum call time can be set from 1 minute to 9 minutes by entering the appropriate number in position #42. A “0” will yield a 30 second time. To disable the call timer enter “#42” without any preceding digit. 6 H. Door Strike Code A one or two digit door strike code can be entered by programming position #41. When in programming, enter the one or two digit code followed by “#41”. Note: “,” and “#” can be entered as valid characters of the door strike code by substituting “#20” and #21” (respectively) when programming the door strike code (see section D). To disable the door strike relay, enter “#41” without any preceding numbers. The following are examples of door strike code entries: To Program the Door Strike Code to... Step 1 (see section A) Step 2 - Enter Digits ”99” Enter programming 99#41 ”3” Enter programming 3#41 ”,,” Enter programming #20#20#41 ”#1” Enter programming #211#41 ”, ” Enter programming #20#41 I. Maximum Ring Time This timer sets the maximum amount of time the K-1200 will look for the call to be answered. If this timer expires and the tenant has not answered, the call will be terminated or the K-1200 will dial a second phone number (if programmed). The factory setting is 20 seconds, and to disable this feature, enter “00” into position 43. J. Silence Time Out This time out is started once the call has been connected and is reset every time audio is detected on the phone line. If it expires, the call will be terminated. This is useful on systems that are silent when the tenant hangs up to assure the K-1200 disconnects. It is factory set to 10 seconds and can be disabled by entering “00” in position 44. K. Talk/Listen Delay This time represents the amount of time the K-1200 will delay before switching back to the microphone mode after it was in the speaker mode (VOX switching time). It is in 100 msec increments and stored in position 45. L. Dialing Speed On some phone lines, a faster rate of dialing is allowed. The dialing speed of the K-1200 can be altered to take advantage of this faster rate. The normal dialing speed is 5 digits per second and is selected by entering “#30” (factory setting) while in programming. To increase the speed to 10 digits per second, enter “#31”. If the faster rate is selected, be sure to test each number to assure proper operation. M. Hang Up on Return to Dial Tone The K-1200 is factory set to hang up if continuous audio is detected after dialing. In most situations this would happen if the tenant hung up and the service that the K-1200 is connected to provides a dial tone following the hang up. In some instances due to noisy lines or loud background noise, the call may be terminated before the tenant hangs up. If this occurs, enter “#33” when in programming. This will disable return to dial tone feature and stop the K-1200 from hanging up prematurely. To enable this feature enter “#32” when in programming. N. Special Commands To clear all speed dial positions and set all modes back to factory setting, enter “###“ while in programming. Caution, all previous programming will be lost. Normally when the K-1200 is in the programming mode, it will hang up the line if no commands are detected for 20 seconds. To hang up immediately, enter “##7”. O. DIP Switch Programming/Speaker and Microphone Adjustments Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations the microphone sensitivity may need to be decreased as shown below. Caution: Setting the microphone gain too high may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing. Switch Position Description 1 ON Incoming calls answered (factory setting) 1 OFF Incoming calls not answered 2&3 ON Audio Detection normal (factory setting) 2&3 OFF Audio Detection more sensitive 4 ON Learn Mode - Any incoming calls are automatically entered into the programming mode, no security code required. Use this option if you have forgotten your security code. 4 OFF Normal operation mode (factory setting) Turn POTS clockwise to increase (as viewed from the back of the board). On some phone lines, busy and ring back tones maybe very soft. In these installations, set DIP switches 2 and 3 to the OFF position Microphone Sensitivity POT ON OFF Speaker Volume POT on 1 2 3 4 1 2 3 4 7 Operation When a visitor is at the K-1200, they just need to find the name of the tenant they want to visit on the directory and press the associated button. The K-1200 will then seize the phone line and speed dial the number programmed for that name. When the tenant answers the call, they can let the visitor in by entering the Door Strike Code on their telephone keypad. The tenant can converse with the visitor for up to 10 seconds after the Door Strike Code is dialed (to verify the visitor has been granted entry). The K-1200 is able to determine if the door strike command is coming from the apartment or the caller, to prevent entry using a hand held touch tone dialer. If the tenant chooses not to let the visitor in, they can simply hang up the phone. The K-1200 will drop the line when busy, reorder, CPC signals are detected, when programmable maximum call time out, silence time out, maximum ring timers expire or 10 seconds after a door strike activation. Only the buttons that have a programmed phone number are active (except “#” when used for keyless entry). After a button is pressed, and the call is initiated, it can be canceled by momentarily pressing any button on the panel. If a second number is programmed for the selected tenant, and there is no answer or busy after dialing the first number, the K-1200 will hang-up, pause, seize the line, and then dial this second number. In this manner the call can be routed to a cell phone if the tenant is not at home. The tenant can still let the visitor in using the Door Strike Code. It is also possible to talk to a visitor before they press a directory button. Make sure DIP switch 1 is on (Auto Answer, see section O) and then call the phone number of the K-1200. The K-1200 will answer the ringing line and send a single beep. At this time the user is free to converse with the visitor. For security reasons, the tenant is blocked from operating the door strike in this mode. To use the keyless entry feature, momentarily press or press and hold the “#“ key on the K-1200 keypad. When momentarily pressed, 1 beep will be heard and if held for 2 seconds (or longer), 2 beeps will be heard. In either case, the K-1200 is then ready to accept the keyless code. Continue by entering one of the previously programmed keyless codes. The K-1200 will pause a few seconds to make sure there are no more keypad entries, and then actuates the Door Strike relay if valid. If an incorrect code is entered, the K-1200 will beep 3 times and the user has to start over and enter a correct code. If a Postal Lock is used, a momentary closure of the postal lock switch will energize the door strike for the programmed Door Strike Time. Directory Forms Product Support Line...715.386.8666 Fax Back Line...715.386.4345 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes. 8 Fax Back Doc 182 Printed in the U.S.A. ZF302600 Rev B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:10:12 14:49:13-05:00 Create Date : 2009:10:12 14:46:30-05:00 Metadata Date : 2009:10:12 14:49:13-05:00 Format : application/pdf Title : K-1200 Technical Practice Creator : Viking Electronics, Inc. Description : Multi-Button Handsfree Entry Phone Document ID : uuid:6d641b93-3f5a-4c36-8a4c-533a46cd8646 Instance ID : uuid:b203c22b-54dc-4d80-83fa-196949f060b7 Page Count : 8 Subject : Multi-Button Handsfree Entry Phone Author : Viking ElectronicsEXIF Metadata provided by EXIF.tools