K 1200 Technical Practice Viking 1200/K EWP Multi Button Handsfree Entry Phone Tech Info

User Manual: Viking K-1200/K-1200-EWP Multi Button Handsfree Entry Phone Tech Info VIKING Apartment Entry Systems

Open the PDF directly: View PDF PDF.
Page Count: 8

The K-1200 Entry Phone is a two-way, handsfree telephone with 12
buttons for calling individual residences in an apartment building.
The rugged stainless steel faceplate has a printed directory housed
in a waterproof, scratch-resistant lens. Each button is beside the ten-
ants name in the directory so there are no confusing codes to deal
with. Calling a particular tenant is as easy as pressing a single but-
ton. The K-1200 has a built in speed dialer that can handle up to 12
primary phone numbers, each with 22 digits. If there is no answer at
the first number, a second number can be called automatically. Once
the tenant answers their phone, a single touch tone command can
activate the door strike relay. For “no phone line” applications, the K-
1200 is compatible with the C-3000 no CO (phone line) controller.
For outdoor applications, the K-1200 is available with Enhanced
Weather Protection. EWP products feature rubber gaskets and
boots, closed cell foam gasketing, silicone sealed connections, anti-
corrosive gel filled butt connectors, as well as urethane encapsulat-
ed circuit boards with internally sealed trim POTS and DIP switches.
12 Button Apartment Entry Phone with
Built-In Door Strike Relay
P
Ph
ho
on
ne
e.
..
..
.7
71
15
5.
.3
38
86
6.
.8
88
86
61
1
w
ww
ww
w.
.v
vi
ik
ki
in
ng
ge
el
le
ec
ct
tr
ro
on
ni
ic
cs
s.
.c
co
om
m
• Operates on 12 to 24 volts AC/DC
• 12 speed dial buttons (22 digits each)
• 12 alternate number positions (22 digits each)
• One button operation (no call button)
• Hang-up on CPC, busy, silence, time-out or
dial tone return
• Touch tone restriction from microphone
• Integral relays for camera control and door
strike
• Works with C-1000B for increased security
• Works with C-3000 for “No CO” (phone line)
operation
• Optional Enhanced Weather Protection (EWP)
• 50 keyless entry codes
• See model K-1205 for integral camera
• Postal lock input
Power: 12 to 24 Volts AC or DC, 12VDC adapter provided
Note: To assure operation during a power outage, a UPS should be used.
Dimensions: 127mm x 254mm x 63.5mm (5" x 10" x 2.5")
Shipping weight: 2.2 kg (4.8 lbs.)
Operating Temp: -35°C to 66°C (-30°F to 150°F)
Relay Contact Rating:
Door Strike: 5A @ 30VDC/250VAC Maximum
Camera: 0.5A @ 125 VAC, 1.0A @ 30VDC
Connections: (8) gel-filled butt connectors (3M Scotchlok UR2)
P
Pr
ra
ac
ct
ti
ic
ce
e
T
TE
EL
LE
EC
CO
OM
MS
SO
OL
LU
UT
TI
IO
ON
NS
SF
FO
OR
RT
TH
HE
E2
21
1S
ST
TC
CE
EN
NT
TU
UR
RY
Y
TECHNICAL
TECHNICAL
F
Fe
ea
at
tu
ur
re
es
s
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
ns
s
• Small apartment buildings
• Professional buildings
• Gated communities
A
Ap
pp
pl
li
ic
ca
at
ti
io
on
ns
s
i
in
nf
fo
o@
@v
vi
ik
ki
in
ng
ge
el
le
ec
ct
tr
ro
on
ni
ic
cs
s.
.c
co
om
m
K-1200
K-1200
K-1200-EWP
K-1200-EWP
Multi-Button Handsfree
Entry Phone
October 7, 2009
Model K-1200 (shown in optional
VE-5x10-SS, not included)
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday through Friday 8am - 5pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Technical Practice in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer
MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and trou-
bleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the
date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor
will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same
R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed
the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number.
The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as
options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equip-
ment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment
should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D.
or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics,1531 Industrial St, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manu-
factured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's
Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FIT-
NESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAM-
AGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL
BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLU-
SIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED
AS SUCH.
2
If trouble is experienced with the K-1200, for repair or warranty information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666
If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the
equipment until the problem is resolved.
Connection to Party Line Service is subject to State Tariffs. Contact the state public utility commission, public service com-
mission or corporation commission for information.
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak
hours, such as early morning or late evenings.
It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This
is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radi-
ate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the side of this
equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If
requested, this number must be provided to the telephone company.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive REN's on a
telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of
the REN's should not exceed five (5.0) To be certain of the number of devices that may be connected to a line, as deter-
mined by the total REN's, contact the local telephone company. For products approved after July 23, 2001, the REN for
this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the
REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.
The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable
FCC Part 68 rules and requirements adopted by the ACTA. If your home has specially wired alarm equipment connected
to the telephone line, ensure the installation of this K-1200 does not disable your alarm equipment. If you have questions
about what will disable alarm equipment, consult your telephone company or a qualified installer.
If the K-1200 causes harm to the telephone network, the telephone company will notify you in advance that temporary dis-
continuance of service may be required. But if advance notice isn't practical, the telephone company will notify the cus-
tomer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is nec-
essary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the
operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make
the necessary modifications to maintain uninterrupted service.
VIKING ©
0
#
*
9
8
7
5
4
2
1
10.14"
3.69"
5.22"
Optional VE-5x10 Surface
Mount Box (not included)
10.0"
9.5"
4.50"
2.596"
5.00"
8.65"
0.425"
0.952"
Front View
of the K-1200
9.12"
2.5"
4.5"
- or -
Zinc-Plated Steel
Rough-In Box (included)
Side View
of the K-1200
(8) #6-32 x 3/4"
Stainless Steel
Hexdrive Screws
(included)
A. Mounting
The K-1200 is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor appli-
cations use the K-1200-EWP. The K-1200 can either be installed as a flush mount unit using the included rough in box,
or as a surface mount unit using an optional VE-5x10. The rough in box uses the inner set of four holes on the face
plate while the VE-5x10 uses the outside set of holes. A set of dummy screws and nuts are provided to fill the unused
mounting holes.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet
and the telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact
Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
Rear View
of the K-1200
120V AC
120V AC
CO Line
Doorstrike/Magnetic Lock
Yellow (N.O.)
Brown (COM)
Green
Red
** Gel-Filled Butt Connectors (included)
Black
Black
* Ferrite Core
(included)
White
White
Postal Lock
Switch (N.O.)
Orange (N.C.)
K-1200
260878-1
VIKING
Model:
P/N:
S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
DEV:
Q171360
Q171360
100 W 0.5W
100 W 0.5W
A. Connecting a Doorstrike to the K-1200 Internal Relay
3
The K-1200 can be powered from any source supplying 12 to 24
volts, AC or DC. A 12 volt DC adapter is supplied with the product.
When using the included adapter, the plug on the adapter cord will
have to be removed. The power connections to the K-1200 (black
wires) are not polarity sensitive.
There are also 8 more wires connected to the K-1200 controller
board. Two wires are for the incoming phone line, three are from the
high current door strike relay and the last three are from the camera
relay. Gel filled butt connectors are provided for easier connection to
building wiring. The table at the right describes each wire’s function.
Color
Black
Black
Green
Red
Brown
Orange
Yellow
Blue
Violet
White
Function
Power In
Power In
Phone Line In
Phone Line In
Door Strike Relay common
Door Strike Relay NC
Door Strike Relay NO
Camera Relay common
Camera Relay NC
Camera Relay NO
The K-1200 provides a dry contact output that can be used for operation of a door strike. To use this feature, the Door
Strike Code and Door Strike Time must be set in programming. In this mode, when the Door Strike Code is detected,
the K-1200 will energize the relay for the period of time selected in the Door Strike Time (see Programming section E
and F).
If a Postal Lock is required, connect the normally open contacts of the lock to the two white wires coming from the two
pin connector on the lower portion of the control board. When the postal lock is momentarily actuated, the door strike
will energize for the programmed Door Strike Time.
* Note: To prevent unwanted radio interference, route the connecting wires through the included ferrite core.
** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum
insulation of 0.082 inches. Cut off stripped ends prior to terminating.
To install a directory, remove the four screws that
mount the directory lens to the front of the K-1200
using the included Allen wrench. Insert a paper direc-
tory behind the lens and secure the two back onto the
front panel being careful to align the names with the
front panel graphics. For your convenience, the back
of this document has pre-printed directory forms.
B. Changing the Directory
C. Wiring
A
Ap
pp
pl
li
ic
ca
at
ti
io
on
ns
s
Paper Directory
Directory
Lens
Important: To operate the K-1200 during a power failure, a UPS should be installed.
In some instances it may be a concern that the Door Strike relay is outside the door. In this situation, a second con-
troller such as a C-1000B can be used. Be sure to disable the door strike code for the K-1200 (see Programming sec-
tion H).
Notes: 1. The C-1000B must be in the “Analog Station Mode” (refer to the C-1000B Technical Practice). 2. The K-
1200 keyless entry codes can not be used in this application. 3. The K-1200 will hang-up during doorstrike activation.
C. Using the K-1200 with a C-1000B
4
DOOR ENTRY / CCTV VIDEO
CONTROLLER
VIKING©MODEL C-1000B
PWR 13.8 VAC
DOOR
STRIKE 1
DOOR
STRIKE 2
DOORBOX 2
DOORBOX
PWR OUTPUT
DOORBOX 1
123456789
10 11 12 13 14 15 16 17 18 19
EARTH
GND
P
H
O
NE LIN
E
INPUT
L
INE
OU
T
T
O
PH
O
NE
S
K
EYLE
SS
CO
NTA
C
T
CLOSURE INPUT
E
LE
C
TR
O
NI
CS
HUD
SO
N
,
W
I 54016
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
13.8V AC
Adapter
(included)
120V AC
120V AC
Talk Battery Switch
OFF ON
CO line or Analog
PABX/KSU Station
* Earth
Ground
5A@30V DC/
250V AC maximum
120V AC
Red
Green
Doorstrike/Magnetic Lock 2
ON
1 2 3
DIP Switches
Model
K-1200
ON
OFF
Model C-1000B (not included)
B. Connecting Camera Control to the K-1200 Internal Relay
Blue (COM)
Violet (NC)
White (NO)
Camera
Controller
(not included)
or
Rear View
of the K-1200
120V AC
CO Line
Green
Red
** Gel-Filled Butt
Connectors (included)
Black
Black
* Ferrite Core
(included)
K-1200
260878-1
VIKING
Model:
P/N:
S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
DEV:
Q171360
Q171360
100 W 0.5W
100 W 0.5W
Another internal relay in the K-1200 can be used to trigger a camera controller. When the K-1200 makes a call, it will
energize the relay and hold it on until the call is done.
* Note: To prevent unwanted radio interference, route the connecting wires through the included ferrite core.
** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum
insulation of 0.082 inches. Cut off stripped ends prior to terminating.
2. Accessing the Programming Mode without the Security Code
D. Using the K-1200 with a C-3000
Step 1. Move DIP switch 1 to the ON position (sets unit to answer incoming calls).
Step 2. From a touch tone phone, call the line attached to the K-1200.
Step 3. When the K-1200 answers, listen for the beep and then enter a “#“ followed by the 6-digit security code (factory
set to 845464). A double beep should be heard indicating you have entered the programming mode.
P
Pr
ro
og
gr
ra
am
mm
mi
in
ng
g
A. Accessing The Programming Mode
1. Accessing the Programming Mode with the Security Code
Step 1. Move DIP switch 1 to the ON position (sets unit to answer incoming calls).
Step 2. Move DIP switch 4 to the ON position (incoming calls enter programming without security code, see section B).
Step 3. From a touch tone phone call the line attached to the K-1200.
Step 4. When the K-1200 answers, a double beep should be heard indicating you have entered the programming mode.
Step 5. When finished programming, move DIP switch 4 back to the OFF position.
V
IKIN
G
©
M
ODEL C-3000
VIKIN
G
E
LECTR
O
NIC
S
HUD
SO
N
,
WI 5401
6
12
U
NIT APARTMENT
ENTRY C
O
NTR
O
LLER M
O
D
U
LE
P
O
WE
R
1
3.8 VAC
3
3
4
4
5
5
6
6
7
7
1
1
2
2
D
OO
R
S
TRIK
E
1
D
OOR
S
TRIKE
2
DIP
S
WITC
H
1 2
3
R
J21X
12 APARTMENT LINES IN/OUT
12
8
8
ENTRY
PH
O
NE
1
M
U
LTI-M
O
D
U
L
E
I
NTER
CO
NNE
C
T
S
P
OS
TA
L
L
OCK
I
NP
UT
ENTRY
P
H
O
NE
2
O
UT I
N
PWR
IN
US
E
PROGRAM PHON
E
O
N
O
F
F
Model
K-1200
Red
Red
Green
Green
120V AC
Model
K-1200
120V AC
Model C-3000
(not included)
The K-1200 Entry Controller can be programmed from any Touch Tone phone using a C.O. line, analog PABX/KSU,
or a DLE-200B Line Simulator.
B. Security Code (memory location #47)
This six digit number can be used to access the programming mode. The security code has been factory set to 845464
(V-I-K-I-N-G). It is recommended that you change the security code to a personal 6 digit number. To change the secu-
rity code, access programming (see Programming section A). Enter six digits 0-9 followed by #47. If you have forgot-
ten your security code, follow the steps in Programming section A, 2. Accessing the Programming Mode Without
the Security Code). Note: The security code must be six digits in length and can NOT contain a
,
or #.
C. Keyless Entry Codes
The K-1200 can be programmed with up to 50 keyless entry codes. This feature allows a visitor to let themselves in by
entering a preprogrammed code on the K-1200 keypad. Each keyless code can contain from 1 to 6 digits and is pro-
grammed by entering the digits into any of the locations #50 to #99. To clear a location enter “#” followed by the posi-
tion number without any preceding number. The “,” and “#” keys can also be used in the keyless codes by substitut-
ing “#20” and “#21” (respectively) when programming a keyless position. 5
Notes: 1. In this application, the C-3000 keyless entry feature is not available. Use the keyless entry feature of the K-
1200 and wire both door strike relays in parallel. 2. The K-1200 will hang-up during the doorstrike activation.
For a “No CO” installation, a Viking C-3000 No CO controller can be used with the K-1200. Note, the K-1200 will need to be pro-
grammed on a separate CO line or use the Viking DLE-200B. The door strike can be controlled by the K-1200 or the internal relay
on the C-3000, just be sure to disable the door strike feature in the other unit. The keyless entry feature of the C-3000 can not be
used. If not using keyless entry codes, use the C-3000 to control the doorstrike. If using keyless entry codes (up to 50), use the K-
1200 to control the doorstrike. The K-1200 speed dial position should be programmed with the C-3000 line selection command “1”
to “12”. (Refer to the C-3000 Technical Practice for more details).
Step 2 - Enter Digits
5551234#01
9#233334444#07
23#20#21#08
22#24 (beep) 33#12
Step 1 (see section A)
Enter programming
Enter programming
Enter programming
Enter programming
To Program the K-1200 to...
...store 555-1234 at the first button position
...store a 9, a 1 second pause, then 333-4444 in the seventh button position
...store a 23,# in the eight position
...store a first number of 22 and a second number of 33 in the “#“
button position
G. Maximum Call Time
In some installations, it maybe desirable to limit the length of the call to the tenant. This can be done by programming
position #42. The maximum call time can be set from 1 minute to 9 minutes by entering the appropriate number in posi-
tion #42. A0” will yield a 30 second time. To disable the call timer enter “#42” without any preceding digit.
F. Door Strike Time
The actual time the door strike relay is energized is controlled by location #40. The time can be set from 00 to 99 seconds, (an entry
of “00” gives 0.5 seconds). In order to use this feature, be sure the relay door strike code is set (see section H).
6
E. Speed Dial Numbers
The K-1200 Entry Controller can be programmed with up to twelve 46 digit numbers. Each number can also be programmed with
special features such as pauses, and the Touch Tones “,” and “#”. Each of the special characters count as a single digit. Each of
the speed dial positions #01 to #12 pertain to the corresponding button on the front of the K-1200. The button “0” uses position #10,
the “,” uses position #11 and the “#” uses position #12. To program a speed dial position, enter programming (see section A) then
enter the desired number followed by the selected position. To clear a position, only enter a “#“ followed by the position number with
out any preceding number.
The K-1200 also has the capability to dial a second phone number if there is no answer or busy at the first number. This can be
used if the tenant wants the visitor to call their cell phone if they are not at home. To program a second number, be sure that posi-
tion #43 is programmed with the desired maximum ring time, then enter the first number to be dialed, followed by “#24”. A single
beep should be heard. Next enter the second number to be dialed followed by “#“ plus the memory location. The total number of
digits cannot exceed 46 for each position (45 digits if two numbers are programmed).
The following are examples of speed dial number entries:
D. Quick Programming Features
The K-1200 is programmed through the incoming phone line. The programming commands are structured so that
they do not interfere with the commands of a C-1000B controller.
#01 -#12
#40
#41
#42
#43
#44
#45
#47
#50 - #99
- then - Enter Memory Location
Speed dial numbers ..................................................................................................
Door strike time in sec (factory 05, 00 =.5 sec)**........................................................
Door strike code (factory 6, no digits disables) ..........................................................
Maximum call time in min (factory 3, 0 = .5 min, no digits disables)** .......................
Maximum ring time in sec (factory 20, 00 disables)** ...............................................
Silence Time Out in sec (factory 10, 00 disables)** ..................................................
Talk/listen delay time in .1 sec (factory 2)** ...............................................................
Security code (factory 845464)** ...............................................................................
Keyless entry codes ..................................................................................................
Dial a (,) ..................................................................................................................
Dial a (#) ...................................................................................................................
Add a 4 second pause ..............................................................................................
Add a 1 second pause .............................................................................................
Second phone number selector ................................................................................
Normal dialing speed* ..............................................................................................
Fast dialing speed .....................................................................................................
Hang up on dial tone enable* ...................................................................................
Hang up on dial tone disable ....................................................................................
Reset all programming to factory default settings ...................................................
Hang up from programming ......................................................................................
*Factory settings ** Cannot contain “,“ or “#“ (see #20 and #21)
*** 45 digits maximum if two numbers are programmed in one memory location
Notes: 1. A single or double beep indicates a valid entry, three beeps indicate an error.
2. ,“ or “#“, pauses or second phone number selector occupy one digit of memory.
0-46 digits***
2 digits
1-2 digits
1 digit
2 digits
2 digits
1 digit
6 digits
1-6 digits
#20
#21
#22
#23
#24
#30
#31
#32
#33
###
##7
Enter Digits
then
then
then
then
then
then
then
then
then
Microphone
Sensitivity POT
ON
OFF
1 2 3 4
Speaker
Volume POT
123
on
4
I. Maximum Ring Time
This timer sets the maximum amount of time the K-1200 will look for the call to be answered. If this timer expires and the tenant has
not answered, the call will be terminated or the K-1200 will dial a second phone number (if programmed). The factory setting is 20
seconds, and to disable this feature, enter “00” into position 43.
7
L. Dialing Speed
On some phone lines, a faster rate of dialing is allowed. The dialing speed of the K-1200 can be altered to take advantage of this
faster rate. The normal dialing speed is 5 digits per second and is selected by entering “#30” (factory setting) while in programming.
To increase the speed to 10 digits per second, enter “#31”. If the faster rate is selected, be sure to test each number to assure prop-
er operation.
M. Hang Up on Return to Dial Tone
The K-1200 is factory set to hang up if continuous audio is detected after dialing. In most situations this would happen if the tenant
hung up and the service that the K-1200 is connected to provides a dial tone following the hang up. In some instances due to noisy
lines or loud background noise, the call may be terminated before the tenant hangs up. If this occurs, enter “#33” when in program-
ming. This will disable return to dial tone feature and stop the K-1200 from hanging up prematurely. To enable this feature enter “#32
when in programming.
Switch
1
1
2 & 3
2 & 3
4
4
Position
ON
OFF
ON
OFF
ON
OFF
Description
Incoming calls answered (factory setting)
Incoming calls not answered
Audio Detection normal (factory setting)
Audio Detection more sensitive
Learn Mode - Any incoming calls are auto-
matically entered into the programming mode,
no security code required. Use this option if
you have forgotten your security code.
Normal operation mode (factory setting)
O. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations the micro-
phone sensitivity may need to be decreased as shown below. Caution: Setting the microphone gain too high may cause distort-
ed audio, prevent the distant party from breaking over and inhibit second number redialing.
Turn POTS clockwise to increase
(as viewed from the back of the board).
On some phone lines, busy and ring back tones maybe very soft.
In these installations, set DIP switches 2 and 3 to the OFF position
K. Talk/Listen Delay
This time represents the amount of time the K-1200 will delay before switching back to the microphone mode after it was in the
speaker mode (VOX switching time). It is in 100 msec increments and stored in position 45.
J. Silence Time Out
This time out is started once the call has been connected and is reset every time audio is detected on the phone line. If it expires,
the call will be terminated. This is useful on systems that are silent when the tenant hangs up to assure the K-1200 disconnects. It
is factory set to 10 seconds and can be disabled by entering “00” in position 44.
N. Special Commands
To clear all speed dial positions and set all modes back to factory setting, enter “###“ while in programming. Caution, all previous
programming will be lost. Normally when the K-1200 is in the programming mode, it will hang up the line if no commands are detect-
ed for 20 seconds. To hang up immediately, enter “##7”.
H. Door Strike Code
A one or two digit door strike code can be entered by programming position #41. When in programming, enter the one or two digit
code followed by “#41”. Note: ,” and “#” can be entered as valid characters of the door strike code by substituting “#20” and #21”
(respectively) when programming the door strike code (see section D). To disable the door strike relay, enter “#41” without any pre-
ceding numbers. The following are examples of door strike code entries:
Step 2 - Enter Digits
99#41
3#41
#20#20#41
#211#41
#20#41
Step 1 (see section A)
Enter programming
Enter programming
Enter programming
Enter programming
Enter programming
To Program the Door Strike Code to...
”99”
”3”
,,
”#1”
,
8
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no respon-
sibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc 182 ZF302600 Rev BPrinted in the U.S.A.
P
Pr
ro
od
du
uc
ct
tS
Su
up
pp
po
or
rt
tL
Li
in
ne
e.
..
..
.7
71
15
5.
.3
38
86
6.
.8
86
66
66
6F
Fa
ax
xB
Ba
ac
ck
kL
Li
in
ne
e.
..
..
.7
71
15
5.
.3
38
86
6.
.4
43
34
45
5
When a visitor is at the K-1200, they just need to find the name of the tenant they want to visit on the directory and press the associat-
ed button. The K-1200 will then seize the phone line and speed dial the number programmed for that name. When the tenant answers
the call, they can let the visitor in by entering the Door Strike Code on their telephone keypad. The tenant can converse with the visitor
for up to 10 seconds after the Door Strike Code is dialed (to verify the visitor has been granted entry). The K-1200 is able to determine
if the door strike command is coming from the apartment or the caller, to prevent entry using a hand held touch tone dialer. If the tenant
chooses not to let the visitor in, they can simply hang up the phone. The K-1200 will drop the line when busy, reorder, CPC signals are
detected, when programmable maximum call time out, silence time out, maximum ring timers expire or 10 seconds after a door strike
activation. Only the buttons that have a programmed phone number are active (except “#” when used for keyless entry). After a button
is pressed, and the call is initiated, it can be canceled by momentarily pressing any button on the panel.
If a second number is programmed for the selected tenant, and there is no answer or busy after dialing the first number, the K-1200 will
hang-up, pause, seize the line, and then dial this second number. In this manner the call can be routed to a cell phone if the tenant is not
at home. The tenant can still let the visitor in using the Door Strike Code.
It is also possible to talk to a visitor before they press a directory button. Make sure DIP switch 1 is on (Auto Answer, see section O) and
then call the phone number of the K-1200. The K-1200 will answer the ringing line and send a single beep. At this time the user is free
to converse with the visitor. For security reasons, the tenant is blocked from operating the door strike in this mode.
To use the keyless entry feature, momentarily press or press and hold the “#“ key on the K-1200 keypad. When momentarily pressed, 1
beep will be heard and if held for 2 seconds (or longer), 2 beeps will be heard. In either case, the K-1200 is then ready to accept the key-
less code. Continue by entering one of the previously programmed keyless codes. The K-1200 will pause a few seconds to make sure
there are no more keypad entries, and then actuates the Door Strike relay if valid. If an incorrect code is entered, the K-1200 will beep 3
times and the user has to start over and enter a correct code.
If a Postal Lock is used, a momentary closure of the postal lock switch will energize the door strike for the programmed Door Strike Time.
O
Op
pe
er
ra
at
ti
io
on
n
Directory Forms

Navigation menu