9,67$%3 9,67$%3 &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3URJUDPPLQJ*XLGH 1 OFF ARMED 4 MAX READY 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6 BYPASS 9 CHIME # ARMED READY ON OFF 1 OFF 2 AWAY 4 MAX 5 7 INSTANT READY TEST 8 CODE 0 3 STAY 6 BYPASS 9 CHIME # ® K5894PRV2 9/02 Table of Contents Relay Voice Descriptors ......................................... 39 Relay Voice Descriptors and Custom Word Substitutes Vocabulary........................................ 40 Custom Word Substitutes for VIP Module Annunciation........................................................ 40 Scheduled Check-in ............................................... 41 System Layout Worksheets.................................... 42 Output Devices Worksheets ................................... 58 Scheduling Menu Prompts ..................................... 64 Scheduling Worksheets.......................................... 65 VISTA-128BP Summary of Connections Diagram . 70 VISTA-250BP Summary of Connections Diagram . 71 Recommended Programming Procedure................. 3 Program Field Index ................................................. 4 VISTA-128BP/VISTA-250BP Programming Form ... 5 Partition-Specific Fields.......................................... 12 Programming With #93 Menu Mode ...................... 14 Zone Programming................................................. 15 5800 Series Transmitters Loop Designations ........ 19 Expert Mode Zone Programming ........................... 20 Report Code Programming .................................... 24 Alpha Descriptors Programming ............................ 27 Alpha Descriptor Vocabulary.................................. 31 Device Programming.............................................. 32 Output Programming .............................................. 35 NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. The following table lists the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Feature Number of Zones Number of User Codes Number of Access Cards Event Log Capacity VistaKey Modules VISTA-128BP 128 150 250 512 8 VISTA-250BP 250 250 500 1000 15 The purpose of this document is to provide a quick and easy way to program your entire system. A recommended programming procedure is included, followed by a list of program fields with the corresponding program group they belong to (system-wide, partition-specific, scheduling, etc.). Two program forms are included. One contains all the programming fields, and the other contains the partition-specific fields. If you are setting up a single-partition system, the partition-specific fields become system-wide fields. Following the program forms are system layout worksheets. We recommend that you use these sheets to plan your system before programming is performed. If you need further information about specific programming options, see the VISTA128BP/VISTA-250BP Installation and Setup Guide. Make sure that one two-line alpha keypad is connected to the control and is set to device address "00." Single-Partition System The system default is for a single-partition system. Use the VISTA-128BP/VISTA-250BP SINGLE PARTITION PROGRAMMING FORM when programming for single-partition usage. Follow the steps outlined in RECOMMENDED PROGRAMMING PROCEDURE of this document for proper programming procedure. Multiple-Partition System You must enter the number of partitions you are using in data field 2*00 to set the system for multiple partitions. Use the VISTA-128BP/VISTA-250BP SINGLE PARTITION and the PARTITION-SPECIFIC PROGRAM FORMS when programming the system for multiple partitions. Follow the steps outlined in RECOMMENDED PROGRAMMING PROCEDURE of this document for proper programming procedure. SUMMARY OF PROGRAMMING COMMANDS • • • • • • • • • To enter program mode, enter installer code + [8] + [0] + [0] + [0] To set standard defaults, press ✱97 To change to next page of program fields, press ✱94 To return to previous set of fields, press ✱99 To erase account and phone number field entries, press [✱] + field number + [✱] To assign zone descriptors, press #93 + follow menu prompts To add custom words, press #93 + follow menu prompts To enter Installer's Message, press #93 + follow menu prompts To exit program mode, enter ✱99 OR ✱98: ✱99 allows re-access to programming mode by installer code. ✱98 prevents re-access to programming mode by installer code. Standard default (✱97) values are shown in brackets [ ], otherwise default = 0. –2– Recommended Programming Procedure The following is a step-by-step procedure recommended for programming your VISTA-128BP/VISTA-250BP system. 1. Set the keypads (and other peripheral devices) to the appropriate addresses. 2. Set factory defaults by pressing ✱97. This will automatically enable keypad addresses 00-01, so be sure at least one keypad is set to one of these addresses. Address 01 is also set for AUI. 3. Program system-wide (global) data fields. Using the programming form as a guide, enter program mode and program all system-wide programming fields. These options affect the entire system, regardless of partitions. They include control options, downloader and dialer options, RF options, event logging options, etc. Refer to the Program Field Index for a listing of the program fields and their function. Note that field 2✱00 (number of partitions) must be programmed before continuing. 4. Program partition-specific fields. When the system-wide fields have been programmed, program all partition-specific programming fields by first pressing ✱91 to select a partition (while still in data field program mode). Then enter the first partitionspecific field number ✱09. When you are finished, the next partition-specific field is automatically displayed. Partition-specific fields can have different values for each partition. To program the fields for the next partition, press ✱91, enter the desired partition number, then enter field ✱09. Refer to the MECHANICS OF PROGRAMMING section in the VISTA-128BP/VISTA-250BP Installation and Setup Guide for detailed instructions. 5. Use #93 Menu Mode for device programming. Refer to Device Programming in this guide to assign keypad ID numbers and default partitions for each keypad, and to selectively suppress certain keypad sounding options. Also use this mode to assign RF receivers, relay modules, the VIP module, the ECP Long Range Radio, and the VISTA Gateway Module. 6. Use #93 Menu Mode for zone programming. Refer to Zone Programming in this guide to program zone response types, assign right loop zones and wireless zones, assign zones to partitions, and to program alarm report codes. 7. Use #93 Menu Mode for programming outputs. Refer to Output Programming in this guide to program desired output operation. 8. Program Communication options. Refer to System Communication section in the VISTA-128BP/VISTA-250BP Installation and Setup Guide for detailed instructions. Then use #93 menu mode to program report codes. 9. Use #93 Menu Mode for programming alpha descriptors. Refer to Alpha Programming in this guide to enter zone and partition descriptors and a custom installer's message. 10. Use #93 Menu Mode for relay voice descriptors and custom word substitutes. Refer to Relay Voice Descriptors in this guide for further instructions for programming relay descriptors to be annunciated by the VIP module, as well as the Custom Index section for custom word substitutes. 11. Use #80 Mode for programming schedules. Refer to the Scheduling Menu Prompts in the VISTA-128BP/VISTA-250BP Installation and Setup Guide to program open/close schedules, temporary and holiday schedules, limitation of access schedules, and timedriven events. 12. Define user access codes. Refer to User Access Codes in the VISTA-128BP/VISTA-250BP Installation and Setup Guide to program authority level, O/C reporting option, partition assignments, and RF key assignments for each user. 13. Exit Programming Mode. Exit programming mode by pressing either ✱98 or ✱99. Additional entries of ✱99 are required if the exit is being done from fields 1✱00 and above. To prevent re-access to programming mode using the Installer's code, use ✱98. The only way to re-access programming mode is by depressing both the [✱] and [#] keys at the same time within 30 seconds of powerup. Exiting by using ✱99 always allows reentry into programming mode using the Installer code. Either way of exiting allows access via downloading. Note that if local programming lockout is set via downloading, programming mode cannot be entered at the keypad. –3– Program Field Index On the following pages, the programming fields have been arranged in numerical order. Use this index to cross-reference the fields on the programming form. Field Group Field Group Field Group *00 *04 *05 *06 *09 *10 *11 *12 *13 *14 *15 *16 *17 *19 *20 *21 *22 *23 *24 *25 *26 *27 *28 *29 *30 *31 *32 *33 *34 *35 *36 *37 *38 *39 *40 *41 *42 *43 *44 *45 *46 *47 *48 *49 *50 *51 *52 *53 *54 *56 *57 *58 *59 *79 *80 *83 *84 *85 *87 *88 *89 System-Wide System-Wide System-Wide Partition-Specific Partition-Specific Partition-Specific Partition-Specific Partition-Specific Partition-Specific System-Wide System-Wide Partition-Specific System-Wide System-Wide System-Wide System-Wide Partition-Specific Partition-Specific System-Wide System-Wide Communications Communications System-Wide Partition-Specific Communications Communications Partition-Specific Communications Communications System-Wide System-Wide System-Wide Partition-Specific Partition-Specific Communications System-Wide Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications System-Wide Communications Communications Communications Communications Communications Communications Communications Partition-Specific Partition-Specific Partition-Specific Partition-Specific Communications *90 1*07 1*10 1*15 1*17 1*18 1*19 1*20 1*21 1*22 1*23 1*24 1*25 1*26 1*28 1*29 1*30 1*31 1*33 1*34 1*35 1*42 1*43 1*44 1*45 1*46 1*47 1*48 1*49 1*52 1*53 1*55 1*56 1*57 1*58 1*60 1*69 1*70 1*71 1*72 1*73 1*74 1*75 1*76 2*00 2*01 2*02 2*05 2*06 2*07 2*08 2*09 2*10 2*11 2*18 2*19 2*20 2*21 2*22 2*23 2*24 Partition-Specific System-Wide System-Wide Communications System-Wide Partition-Specific Partition-Specific System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide Partition-Specific System-Wide System-Wide System-Wide System-Wide Communications Communications communications Communications Partition-Specific System-Wide Partition-Specific System-Wide Partition-Specific System-Wide System-Wide Partition-Specific System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide System-Wide Partition-Specific System-Wide System-Wide System-Wide Partition-Specific Partition-Specific Partition-Specific Partition-Specific Partition-Specific Partition-Specific System-Wide Partition-Specific System-Wide Partition-Specific System-Wide Partition-Specific Partition-Specific Partition-Specific –4– 2*30 2*31 2*32 2*33 2*34 2*35 2*36 2*37 2*38 2*39 2*40 2*41 2*42 2*43 2*44 2*45 2*46 2*47 2*48 2*49 2*50 2*51 2*52 2*53 2*54 2*55 2*56 2*57 2*58 2*59 2*60 2*61 2*62 2*63 2*64 2*65 2*66 2*67 2*68 2*69 2*70 2*71 2*72 2*73 2*74 2*75 2*76 2*77 2*78 2*79 2*80 2*81 2*82 2*83 2*84 2*85 2*86 2*87 2*88 Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications Communications VISTA-128BP/VISTA-250BP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section for programming these fields. Standard default (*97) values are shown in brackets [ ]; otherwise, default = 0. | | | *00 INSTALLER CODE | *20 VIP MODULE PHONE CODE Enter 4 digits, 0-9 [4140] Enter 01 - 09 for the first digit; enter 11 for “*” or 12 for “#” for the second digit. Must be set to "0" for UL installations. *04 ENABLE RANDOM TIMERS | [00], *21 PREVENT FIRE TIMEOUT 1 2 3 4 5 6 7 8 Enter 1 to make available the randomizing of pre-programmed time driven events for each partition. [0=disable]. *05 SYSTEM EVENTS NOTIFY | [04] | [06] 00, 02-15 times 15 seconds (must be longer than Entry Delay #1). Maximum "03" for UL installations. The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute for SIA installations. | [08] 00, 03-15 times 15 seconds (must be longer than Exit Delay #1). Maximum "04" for UL installations. Minimum 45 seconds “03” for SIA installations. 01-15 times 2 minutes. Must be minimum 16 minutes for UL installations. Must be minimum 6 minutes for SIA installations. [0] Enter 1 to set terminal 23 as a RS232 input to enable system to receive serial data (75 baud) via terminal 23. Enter 0 to enable terminal 23 as burglary input for zone 9. *15 KEYSWITCH ASSIGNMENT [1] [0] *25 BURG.TRIGGER FOR RESPONSE TYPE 8 *26 INTELLIGENT TEST REPORTING [0] 1=yes (no report sent if any other report was recently sent); 0=no (send report at programmed interval, field *27) Must be 0 for UL installations. [0024] *27 TEST REPORT INTERVAL | | | Enter interval in hours, 0001-9999; 0000=no report; Max. 0024 for UL installations. *28 POWER UP IN PREVIOUS STATE [1] 1=yes; 0=no; "1" for UL installations. *29 QUICK ARM [1] 1=yes; 0=no *30 TOUCHTONE OR ROTARY DIAL [0] 1=TouchTone; 0=rotary *31 PABX ACCESS CODE | | | | | | | | 00-09; B-F (11-15) *32 PRIM. SUBS. ACCT # Enter 00-09; B-F (11-15) [15 15 15 15] *33 PRIMARY PHONE NUMBER [0] Enter partition in which keyswitch used, 1-8; 0=disable *16 CONFIRMATION OF ARMING DING *17 AC LOSS KEYPAD SOUNDING Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause [0] *34 SECONDARY PHONE NUMBER 1=enable; 0=disable. Must be "1" for UL Installations. [0] 1=yes; 0=no *19 RANDOMIZE AC LOSS REPORT [1] 1=enable; 0=disable | [04] 999 1=Ignore; 0=Enable tamper for RF and RPMs. Must be "0" for UL installations if using these devices. | [02] 00, 03-15 times 15 seconds Maximum "04" for UL installations. Minimum 45 seconds “03” for SIA installations. *14 BURGLARY OR RS232 INPUT 996 *24 IGNORE EXPANSION ZONE TAMPER 00, 02-15 times 15 seconds Maximum "03" for UL. The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute for SIA installations. *13 ALARM SOUNDER DURATION 995 1=yes; 0=no [1] *09 ENTRY DELAY #1 *12 EXIT DELAY #2 [001] 1=enable; 0=disable 1=enable; 0=disable *11 ENTRY DELAY #2 *22 KEYPAD PANIC ENABLES *23 MULTIPLE ALARMS *06 QUICK EXIT *10 EXIT DELAY #1 [0] 1=No timeout; 0=Timeout. [0] 1=yes, (messages sent via the RS232 port). 0=no, (no messages sent). [11] Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause [0] 1=10-40 min; 0=normal report (about 2 min. after AC loss). –5– *35 DOWNLOAD PHONE NO. *52 STANDARD/EXPANDED REPORT FOR PRIMARY [0 0 0 0 0 0] Alarm Rstr Byp Trbl O/C LoBat 0=standard; 1=expanded; Note: Expanded overrides 4+2 format. Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause *53 STANDARD/EXPANDED REPORT FOR SECONDARY *36 DOWNLOAD ID NO. | | | | | | | [0 0 0 0 0 0] | Alarm Rstr Byp Trbl O/C LoBat 0=standard; 1=expanded; Note: Expanded overrides 4+2 format. Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15] *37 DOWNLOAD COMMAND ENABLES *54 UNATTENDED MODE 0 0=No, 1=Yes, if automatic downloads will be allowed Dlr ShtdwnSys Shtdwn Not UsedRmt BypRmt DisarmRmt ArmUpld PgmDwnld Pgm See field 1*53 for Callback disable option; [1=enable]; 0=disable. For UL installations, all entries must be "0." *38 PREVENT ZONE XXX BYPASS [000] [1] *56 DYNAMIC SIGNALING DELAY | | 001-250; 00 if all zones can be bypassed *57 DYNAMIC SIGNALING PRIORITY *39 ENABLE OPEN/CLOSE REPORT FOR | [00] Select the delay time (00-15) times 15 seconds before sending to second destination. [1] [0] 0=Primary dialer; 1=LRR, as first reporting destination. *58 LRR CENTRAL STATION #1 CATEGORY ENABLE INSTALLER CODE 1=enable; 0=disable *40 OPEN/CLOSE REPORT FOR KEYSWITCH [0] [0 0 0 0 0 0] Alarm Trbl 1=enable; 0=disable Byp O/C Syst Test 0=disable, 1=enable for reports for primary subs ID of LRR *41 NORMALLY CLOSED or EOLR (Zones 2-8) [0] *59 LRR CENTRAL STATION #2 CATEGORY ENABLE 1=N.C.loops; 0=EOLR supervision. Must be "0" for UL installations. [0 0 0 0 0 0] Alarm Trbl *42 DIAL TONE PAUSE [0] Byp O/C Syst Test 0=disable, 1=enable for reports for secondary subs ID of LRR 0=5 seconds; 1=11 seconds; 2=30 seconds. Must be "0" UL Installations. ZONE TYPE RESTORE ENABLES *43 DIAL TONE DETECTION *79 FOR ZONE TYPES 1-8 [1] 1=wait for true dial tone; 0=pause, then dial *44 RING DETECTION COUNT 1 2 3 4 5 1=enable; [0=disable] | [00] 01-14; 15=answering machine; 00=no detection. Must be "00" for UL Burglary. 6 7 8 *80 FOR TYPES 9, 10 and 16 9 *45 PRIMARY FORMAT [1] 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; 3= ADEMCO Express *46 LOW SPEED FORMAT (Primary) *50 SESCOA/RADIONICS SELECT | 01-15 alarms Must be "00" (disabled) for UL. *85 ENABLE DIALER REPORTS FOR PANICS & DURESS [0] 1=enable; [0=disable] 995 996 999 Duress *87 ENTRY WARNING [0] [0] Prim [1] 1=continuous; 0=3 beeps Sec *88 BURG. ALARM COMM. DELAY [0] [1] 1=30 seconds; 0=no delay Must be "0" for UL installations. Must be “1” for SIA installs. 1=Sescoa; 0=Radionics *51 DUAL REPORTING | [01] 0= ADEMCO Low Speed; 1=Sescoa/Radionics 1=yes; 0=no | *84 SWINGER SUPPRESSION [1] 0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed; 3= ADEMCO Express *49 CHECKSUM VERIFICATION 16 [Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 0059; 00 in all boxes = instant (Day 01= Monday) 0= ADEMCO Low Speed; 1=Sescoa/Radionics *48 LOW SPEED FORMAT (Sec.) | *83 FIRST TEST REPORT TIME [0] *47 SECONDARY FORMAT 10 1=enable; [0=disable] [0] 1=yes; 0=no If used with Spilt Reporting "1" option (1*34), alarms and alarm restores go to both primary & secondary numbers, while all other reports go to secondary only. If used with Split Reporting "2" option, alarms and alarm restores go to both, open/close and test messages go to secondary only, while all other reports go to primary. *89 RESTORE REPORT TIMING [0] 0=Instant; 1=After bell timeout if zone is restored; 2=when system is disarmed. Must be "0" for UL installations. *90 SEC. SUBS. ACCT # –6– Enter 00-09; B-F (11-15) | [15 15 15 15] | | | 1*07 CHECK OR TRBL DISPLAY 1*33 TOUCHTONE W/ROTARY BACKUP [0] 1=display TRBL; 0=display CHECK 1=enable; 0=disable 1*10 FIRST TO ALARM DISPLAY LOCK 1*34 COMM. SPLIT REPORTING [0] 0=scroll all alarms; 1=lock display of first fire alarm. 1*15 CANCEL VERIFY [1] 0=disable, 1=enable alarm output pulse upon kissoff of Cancel report. Note: Field 1✳52 must be enabled to send a Cancel report to the central station. 1*17 LOBBY PARTITION 1*35 Trace Trbl 1*19 ARMS LOBBY 1*43 PERM. KEYPAD BACKLIGHT 1*44 WIRELESS KEYPAD TAMPER Enter 1 if arming this partition attempts to arm lobby; enter 0 if it does not. Must be "0" for UL installations. 1*45 EXIT DELAY SOUNDING 0=No; 1=Resets Exit Delay to programmed value after zone is closed and then faulted prior to end of exit delay. Must be "0" for UL installations. Exit Delay must be enabled for SIA installations. 1*46 AUXILIARY OUTPUT MODE 1*23 CROSS-ZONING PAIR TWO | | | | 1*24 CROSS-ZONING PAIR THREE | | | | 1*25 CROSS-ZONING PAIR FOUR | | | | 1*26 PANIC BUTTON OR SPEEDKEY 1*47 CHIME ON EXTERNAL SIREN 1*48 WIRELESS KEYPAD ASSIGNMENT MISCELLANEOUS WIRELESS OPTIONS Fields 1*28 - 1*31 are not applicable for UL installations. 1*55 EUROPEAN DATE FORMAT 1*56 AC 50/60 Hz CLOCK SPEED 1*57 5800 RF BUTTON GLOBAL ARM [12] [0] [0] 1=50 Hz; 0=60 Hz. | 02-15 times 2 hours; 00 disables supervision 1*31 RF XMITTER CHECK-IN INTERVAL [0] 0=disable (mm/dd/yy); 1=enable (dd/mm/yy). [0] [06] [1] 1=no restriction; 0=within bell timeout period only Must be enabled “1” for SIA installations. [0] 1=enable; 0=disable 1*30 RF RCVR CHECK-IN INTERVAL 1*52 SEND CANCEL IF ALARM + OFF 1=callback not required; 0=callback required. Must be "0" for UL installations. 1=immediate; 0=when disarmed 1*29 RF TX LOW BATTERY REPORTING [1] 1=disable; 0=enable. Must be "0" for UL installations. 1*53 DOWNLOAD CALLBACK 1*28 RF TX LOW BATTERY SOUND [0] 0=disable; enter partition in which RF keypad used, 1-8. Must be "0" for UL installations. | A B C D Enter speedkey macro # (01-32) to use keys A-C for macro. Otherwise enter 00 to use as panic. For D key, enter macro # or 00 to select macro when key is pressed. [0] 1=enable; 0=disable 1*49 SUPPRESS TX SUPERVISION SOUND | [0] Enter 0 for ground start output. Enter 1 for smoke detector reset. Enter 2 for keypad-like sounding. This option applies only to the VISTA-128BP and to the partition enabled in field *15. Enter 3 if AAV module is being used. NOTE: Only one of the above options may be active within the system. FIELDS 1✳22-1✳25: Allow four sets of two zones each to be linked so that both must fault within a five minute period to cause an alarm. Default for these fields = [000], [000]. | | [1] 1=enable; 0=disable. Produces quick beeping during exit delay if enabled. NOTE: See page 32, “SOUND OPTION”, prompt for disabling the entry/exit beeps on individual keypads. [0] | | [0] 1=enable; 0=disable. Must be "0" for UL installations. [1] 1*22 CROSS-ZONING PAIR ONE [0] DETECTION 0=No; 1=Bypass E/E and Interior zones faulted after exit delay. Must be "0" for UL installations. 1*21 EXIT DELAY RESET [0] 1=enable; 0=disable When disabled, display lights when any key is pressed, and turns off after period of keypad inactivity. [0] 1*20 EXIT ERROR LOGIC ENABLE Alm 1=Yes; 0=No Enter 1 if this partition affects the common lobby; enter 0 if it does not. Must be "0" for UL installations. [00, 00, 00, 00] Byp Not Used Syst 1=enable; 0=disable [0] | 0=no; 1=alarms and alarm restores primary, others secondary; 2=open/close, test secondary, others primary. See ✴51 for comments if using with dual reporting. ACCESS CONTROL DIALER ENABLES 1*42 CALL WAITING DEFEAT 1*18 AFFECTS LOBBY [0] [0 0 0 0 0 0] [0] Enter the "common lobby" partition (1-8) | [0] 1=enable; 0=disable | 02-15 times 2 hours; 00 disables transmitter supervision –7– [0] 1*58 5800 RF BUTTON FORCE ARM 2*06 AUTO-ARM WARNING PERIOD [0] Enter "1" to enable. If a zone is faulted after pressing button, keypad will beep once. Pressing the button again within 4 sec. bypasses the zone. Enter "0" to disable. Must be "0" for UL installations. 1*60 ZONE 5 AUDIO ALARM VERIFICATION This is the time during which the user is warned to exit the premises prior to the auto-arming of the system (beeps every 15 seconds; "ALERT" displayed). Enter 01-15 minutes. 00=instant at end of arming delay. 2*07 AUTO-DISARM DELAY [0] Enter 1 If 2-way audio (AAV) is being used; Enter 0 if it is not. Must be "0" for UL installations. 1*69 PRINTER TYPE 2*08 ENABLE FORCE ARM FOR AUTO-ARM [0] 2*09 OPEN/CLOSE REPORTS BY EXCEPTION [0] 1=enable; 0=disable If enabled, only openings and closings occurring outside the scheduled opening/closing windows will trigger dialer reports. Opening reports will also be suppressed during the closing window, in order to prevent false reports when the user arms the system and then reenters the premises to retrieve a forgotten item. [1 0 0 0 1] O/C Syst 1=enable; 0=disable 1*71 12/24 HOUR TIME STAMP FORMAT [0] 0=12 hour; 1=24 hour 2*10 ALLOW DISARMING ONLY DURING 1*72 EVENT LOG PRINTER ON-LINE ARMING/DISARMING WINDOWS [0] 0=disable; 1=enable See system-wide field 2*11 if enabling field 2*10. This feature adds high security to the installation. 2*11 ALLOW DISARM OUTSIDE WINDOW 1=300; 0=1200 Must be 1200 if using pager interface. Used only if field 2*10 (partition-specific field) is set to "1." If this field is enabled ("1") the system can be disarmed outside the disarm window if an alarm has occurred. If "0," disarming can only be done during the disarm window. If field 2*10 is set to "0" for a partition, this field has no effect for that partition. Enter the relay timeout, 0-127 in multiples of 2 minutes, desired for #80 Menu Mode time-driven event relay command numbers "04/09" and #93 Menu Mode Output Programming output command "56." | | 1*75 RELAY TIMEOUT YYY SECONDS [000] 2*18 ENABLE GOTO FOR THIS PARTITION Enter the relay timeout, 0-127 seconds, desired for #80 Menu Mode time driven event relay command numbers "05/10" and #93 Menu Mode Output Programming command "57." 1*76 ACCESS CONTROL RELAY 2*19 USE PARTITION DESCRIPTORS 2*20 ENABLE J7 TRIGGERS FOR PARTITION 2*21 ENABLE SUPERVISION PULSES FOR LRR TRIGGER OUTPUTS 2*00 NUMBER OF PARTITIONS [1] | | Start End [1, 5] | 2*22 DISPLAY FIRE ALARMS OF 00-12; if no daylight saving time, enter 00,00 START/END WEEKEND | Enter the time between the end of the arming window and the start of auto-arming warning period, in values of 1-14 times 4 minutes 00=instant; [15=no auto arm at all]. When this delay expires, the Auto-Arm Warning Period begins. B [0] 0=No; 1=Yes. Start | End [15] | | OTHER PARTITIONS Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=3rd from last [1,5] 2*05 AUTO-ARM DELAY [000] F Used for supervised connection to 7920SE. Enter 0 to disable or 1 to enable the listed outputs. F= Fire; B= Burglary; P= Silent Panic/Duress. Must be 1 for UL. Installations. Enter 1-8 2*02 DAYLIGHT SAVING TIME [1] 0=disable for displayed partition; 1=enable for displayed partition 3rd Page Programming Fields (press *94) START/END MONTH [0] 0=disable; 1=enable Relay will be pulsed for 2 seconds whenever code + [0] is pressed. Enter 00-96; 00=none. Must be "00" for UL. 2*01 DAYLIGHT SAVING TIME [04, 10] [0] 1=Allow log-on from other partitions; 0=disable | [00] [0] IF ALARM OCCURS | | 1*74 RELAY TIMEOUT XXX MINUTES [000] [0] [0] 0=disable; 1=enable 1*73 PRINTER BAUD RATE [0] 0=disable; 1=enable 1*70 EVENT LOG TYPES Byp | [15] This is the time between the end of the disarming window and the start of auto-disarming. Enter 01-14 times 4 minutes; 00=instant at end of window; 15=no auto-disarm. Enter 0 if you are using a parallel printer connected to the VA8201 Alpha Pager Module. Enter 1 if you are using a serial printer. Alarm Chk | [15] 2*23 DISPLAY BURG & PANIC ALARMS OF [0] OTHER PARTITIONS 0=No; 1=Yes. 2*24 DISPLAY TROUBLES OF OTHER PARTITIONS 0=No; 1=Yes –8– [0] P 2*30 PAGER INSTALLED 1=Yes; 0=No [0] 2*44 PAGER 2 DELAY 2 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. 2*31 DELAY PAGING 1 2 3 4 5 [0=disable]; 1=enable 6 7 2*45 PAGER 2 PARTITION ENABLE 8 2*32 TIME TO DELAY PAGING AFTER DIALER [000] 000 – 024 times 10 seconds 1 2 3 4 5 1=enable; [0=disable] | | If field 2*31 is enabled, enter the time to delay before the pager sends the message. 6 7 8 2*46 PAGER 2 TRIGGER EVENT ENABLES 2*33 PAGER 1 PHONE NUMBER Alarm Trbl Byp O/C Syst 1=enable; [0=disable] 2*47 PAGER 3 PHONE NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause 2*34 PAGER 1 ID NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause Enter the pager 1 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 2*35 PAGER 1 FORMAT 2*48 PAGER 3 ID NUMBER [0] Enter the pager 3 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 0= Numeric; 1=ID; 2=Alphanumeric 2*36 PAGER 1 DELAY 1 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. 2*37 PAGER 1 DELAY 2 [000] 2*49 PAGER 3 FORMAT 0= Numeric; 1=ID; 2=Alphanumeric 2*50 PAGER 3 DELAY 1 2*51 PAGER 3 DELAY 2 6 7 Byp O/C [000] | | 2*52 PAGER 3 PARTITION ENABLE 8 2*39 PAGER 1 TRIGGER EVENT ENABLES Alarm Trbl | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. 2*38 PAGER 1 PARTITION ENABLE 1 2 3 4 5 1=enable; [0=disable] [000] Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. [0] 1 2 3 4 5 1=enable; [0=disable] 6 7 8 2*53 PAGER 3 TRIGGER EVENT ENABLES Syst 1=enable; [0=disable] 2*40 PAGER 2 PHONE NUMBER Alarm Trbl Byp O/C Syst 1=enable; [0=disable] 2*54 PAGER 4 PHONE NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause 2*41 PAGER 2 ID NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause Enter the pager 2 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 2*42 PAGER 2 FORMAT 2*55 PAGER 4 ID NUMBER [0] Enter the pager 4 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 0= Numeric; 1=ID; 2=Alphanumeric 2*43 PAGER 2 DELAY 1 [000] | | 2*56 PAGER 4 FORMAT 0= Numeric; 1=ID; 2=Alphanumeric Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. –9– [0] 2*57 PAGER 4 DELAY 1 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. 2*58 PAGER 4 DELAY 2 [000] 2*70 PAGER 6 FORMAT 0= Numeric; 1=ID; 2=Alphanumeric 2*71 PAGER 6 DELAY 1 2*72 PAGER 6 DELAY 2 2*59 PAGER 4 PARTITION ENABLE 1 2 3 4 5 1=enable; [0=disable] 6 7 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. [0] [000] | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. 2*73 PAGER 6 PARTITION ENABLE 8 2*60 PAGER 4 TRIGGER EVENT ENABLES 1 2 3 4 5 1=enable; [0=disable] Alarm Trbl Byp O/C 6 7 8 2*74 PAGER 6 TRIGGER EVENT ENABLES Syst 1=enable; [0=disable] 2*61 PAGER 5 PHONE NUMBER Alarm Trbl Byp O/C Syst 1=enable; [0=disable] 2*75 PAGER 7 PHONE NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause 2*62 PAGER 5 ID NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause Enter the pager 5 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 2*63 PAGER 5 FORMAT 2*76 PAGER 7 ID NUMBER [0] Enter the pager 7 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 0= Numeric; 1=ID; 2=Alphanumeric 2*64 PAGER 5 DELAY 1 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. 2*65 PAGER 5 DELAY 2 [000] 2*77 PAGER 7 FORMAT 2*78 PAGER 7 DELAY 1 2*79 PAGER 7 DELAY 2 2*66 PAGER 5 PARTITION ENABLE 1 2 3 4 5 1=enable; [0=disable] 6 7 [000] [000] 8 2*80 PAGER 7 PARTITION ENABLE 1 2 3 4 5 1=enable; [0=disable] Byp O/C | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. 2*67 PAGER 5 TRIGGER EVENT ENABLES Alarm Trbl | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. [0] 0= Numeric; 1=ID; 2=Alphanumeric Syst 6 7 8 2*81 PAGER 7 TRIGGER EVENT ENABLES 1=enable; [0=disable] 2*68 PAGER 6 PHONE NUMBER Alarm Trbl Byp O/C Syst 1=enable; [0=disable] 2*82 PAGER 8 PHONE NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause 2*69 PAGER 6 ID NUMBER Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2-second pause Enter the pager 6 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. – 10 – 2*83 PAGER 8 ID NUMBER Enter the pager 8 ID number. Up to 10 digits. Press * after the last digit if less than 10 is required. 2*84 PAGER 8 FORMAT [0] 0= Numeric; 1=ID; 2=Alphanumeric 2*85 PAGER 8 DELAY 1 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the phone number and the pager ID. NOTE: Program only if using numeric format. 2*86 PAGER 8 DELAY 2 [000] | | Enter the delay time 000-060 seconds. The delay occurs between the pager ID and the event information. NOTE: Program only if using numeric format. • • • • • • • • • 2*87 PAGER 8 PARTITION ENABLE 1 2 3 4 5 1=enable; [0=disable] 6 7 8 2*88 PAGER 8 TRIGGER EVENT ENABLES Alarm Trbl Byp O/C Syst 1=enable; [0=disable] – 11 – SUMMARY OF PROGRAMMING COMMANDS To enter program mode, enter installer code + [8] + [0] + [0] + [0] To set standard defaults, press *97 To change to next page of program fields, press *94 To return to previous set of fields, press *99 To erase account and phone number field entries, press [*] + field number + [*] To assign zone descriptors, press #93 + follow menu prompts To add custom words, press #93 + follow menu prompts To enter Installer's Message, press #93 + follow menu prompts To exit program mode, enter *99 OR *98: *99 allows reaccess to programming mode by installer code. *98 prevents re-access to programming mode by installer code. Partition-Specific Fields (Duplicate this page for each partition in the installation.) To program these fields, 1. Press *91 to select a partition. 2. Enter a partition-specific field number (ex. *09). 3. Make the required entry. 4. Repeat steps 1-3 for each partition in the system. PARTITION #____ PROGRAM FIELDS 1st Page Fields *06 QUICK EXIT *84 [1] ENTRY DELAY #1 | [02] *85 00, 02-15 times 15 seconds. Maximum 03 for UL Listed installations. The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute for SIA installations. *10 EXIT DELAY #1 ENTRY DELAY #2 EXIT DELAY #2 ALARM SOUNDER DURATION *90 | [04] *23 995 996 999 QUICK ARM | PREVENT ZONE XXX BYPASS [000] ENABLE OPEN/CLOSE REPORT | | 1*47 CHIME ON BELL 1 [0] [1] [0] 1=enable; 0=disable 001-250; 000 if all zones can be bypassed *39 | 1=enable; 0=disable. Produces quick beeping during exit delay if enabled. NOTE: See page 32, “SOUND OPTION”, prompt for disabling the entry/exit beeps on individual keypads. | | | | 1*45 EXIT DELAY SOUNDING Enter 00-09; B-F (11-15) [15 15 15 15] *38 [0] 1=enable; 0=disable When disabled, display lights when any key is pressed, and turns off after period of keypad inactivity. [1] | [0] 1*43 PERM. KEYPAD BACKLIGHT [1] | [15 15 15 15] A B C D Enter speedkey macro # (01-35) to use keys A-C for macro. Otherwise enter 00 to use as panic. For D key, enter macro # or 00 to select macro when key is pressed. [001] MULTIPLE ALARMS PRIM. SUBS. ACCT # | 1*26 PANIC BUTTON OR SPEEDKEY [0] 1=yes; 0=no *32 | Enter 1 if arming this partition attempts to arm lobby; enter 0 if it does not 1=yes; 0=no. Must be 1 for UL installations. *29 | 1*19 ARMS LOBBY [00, 00, 00, 00] 1=enable; 0=disable [1] Enter 1 if this partition affects the common lobby; enter 0 if it does not. CONFIRMATION OF ARMING DING KEYPAD PANIC ENABLES | SEC. SUBS. ACCT # Enter 00-09; B-F (11-15) 1=enable; 0=disable. Must be "1" for UL installations. *22 BURG. ALARM COMM. DELAY 1*18 AFFECTS LOBBY 01-15 times 2 minutes. Must be minimum 16 minutes for UL installations. Must be minimum 6 minutes for SIA installations. *16 [1] 2nd Page Fields | [08] ENTRY WARNING 1=30 seconds; 0=no delay. Must be "0" for UL installations. Must be “1” for SIA installations. | 00, 03-15 times 15 seconds. Maximum 04 for UL installations. Minimum 45 seconds “03” for SIA installations. *13 *87 1=continuous; 0=3 beeps 00, 02-15 times 15 seconds. Maximum 03 for UL installations. The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute for SIA installations. *12 995 996 999 Duress *88 [06] ENABLE DIALER REPORTS FOR PANICS & DURESS 1=enable; [0=disable] | [04] 00, 03-15 times 15 seconds. Maximum 04 for UL Listed installations. Minimum 45 seconds “03” for SIA installations. *11 | [01] 01-15 alarms; Must be "00" (disabled) for UL installations.. 1=enable; 0=disable *09 SWINGER SUPPRESSION [1] 1*52 SEND CANCEL IF ALARM + OFF FOR INSTALLER CODE 1=no restriction; 0=within Bell Timeout period only Must be enabled “1” for SIA installations. 1=enable; 0=disable – 12 – [1] | 1*76 ACCESS CONTROL RELAY FOR PART.[00] 2*18 ENABLE GOTO FOR THIS PARTITION Relay will be pulsed for 2 seconds whenever code + [0] is pressed. Enter 00-96; 00=none. Must be "00" for UL installations. 1=Allow log-on from other partitions; 0=disable 2*20 ENABLE J7 TRIGGERS BY PARTITION | [15] 2*22 DISPLAY FIRE ALARMS OF Enter the time between the end of the arming window and the start of auto-arming warning period, in values of 1-14 times 4 minutes 00=instant; [15=no auto arm at all]. When this delay expires, the Auto-Arm Warning Period begins. 2*06 AUTO-ARM WARNING PERIOD 0=No; 1=Yes 2*23 DISPLAY BURG/PANIC ALARMS OF | [15] 10=No; 1=Yes 2*24 DISPLAY TROUBLES OF OTHER [0] 0=disable; 1=enable 2*09 OPEN/CLOSE REPORTS BY EXCEPTION [0] 1=enable; 0=disable If enabled, only openings and closings occurring outside the scheduled opening/closing windows will trigger dialer reports. Opening reports will also be suppressed during the closing window, in order to prevent false reports when the user arms the system and then reenters the premises to retrieve a forgotten item. 2*10 ALLOW DISARMING ONLY DURING [0] [0] PARTITIONS 0=No; 1=Yes This is the time between the end of the disarming window and the start of auto-disarming. Enter 01-14 times 4 minutes; 00=instant at end of window; 15=no auto-disarm 2*08 ENABLE FORCE ARM FOR AUTO-ARM [0] OTHER PARTITIONS | [15] [0] OTHER PARTITIONS This is the time during which the user is warned to exit the premises prior to the auto-arming of the system (beeps every 15 seconds; "ALERT" displayed). Enter 01-15 minutes. 00=instant at end of arming delay . 2*07 AUTO-DISARM DELAY [1] 0=disable for displayed partition; 1=enable for displayed partition 3rd Page Fields 2*05 AUTO-ARM DELAY [0] SUMMARY OF PROGRAMMING COMMANDS • • • • • • • • • ARMING/DISARMING WINDOWS See system-wide field 2*11 if enabling field 2*10. This feature adds high security to the installation. 0=disable; 1=enable – 13 – To enter program mode, enter installer code + [8] + [0] + [0] + [0] To set standard defaults, press *97 To change to next page of program fields, press *94 To return to previous set of fields, press *99 To erase account and phone number field entries, press [*] + field number + [*] To assign zone descriptors, press #93 + follow menu prompts To add custom words, press #93 + follow menu prompts To enter Installer's Message, press #93 + follow menu prompts To exit program mode, enter *99 OR *98: *99 allows reaccess to programming mode by installer code. *98 prevents re-access to programming mode by installer code. Programming With #93 Menu Mode NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers should be programmed via Device programming. After programming all system related programming fields in the usual way, press #93 while still in programming mode to display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See page 2 of this manual for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. UL For UL installations, verify that the audio alarm verification feature is disabled. #93 MENU MODE KEY COMMANDS The following is a list of commands used while in the menu mode. #93 Enters Menu mode [✱] Serves as ENTER key. Press to have keypad accept entry. [#] Backs up to previous screen. 0 Press to answer NO 1 Press to answer YES 001-009 All data entries are either 2-digit or 3-digit entries. 000 Exits menu mode, back into field programming mode, when entered at the first question for each category. Menu selections are as follows: PROMPT EXPLANATION ZONE PROG? 1 = YES 0 = NO For programming the following: • Zone Number • Zone Response Type • Partition Number for Zone • Dialer report code for zone • Input Device Type for zone (whether RF, polling loop, etc.) • Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system. • Zone Attributes (e.g., Arm w/Fault, Silent, etc.) EXPERT MODE? 1 = YES 0 = NO 0 0 Same as Zone Programming except: • Done with a minimum number of keystrokes. • Can program wireless keys using pre-defined templates. NOTE: Some of the zone attributes cannot be programmed in the Expert Mode, only in Zone Programming. REPORT CODE PROG? 1 = YES 0 = NO 0 For programming the following: • Alarm report codes for zones • Restore & supervisory codes • All other system report codes ALPHA PROG? 1 = YES 0 = NO For entering alpha descriptors for the following: • Zone Descriptors • Installer's Message • Custom Words • Partition Descriptors • Relay Descriptors DEVICE PROG? 1 = YES 0 = NO 0 0 For defining the following device characteristics for addressable devices, including keypads, RF receivers (5881), output relay modules (4204/4204CF), FSA modules, 4285/4286 VIP Module, ECP Long Range Radio (7820), Panel Link module, and VISTA gateway module: • Device Address • Device Type • Keypad Options (incl. partition assignment) • RF House ID • LRR Options (incl. programming radio) • Panel Linking Options – 14 – PROMPT EXPLANATION OUTPUT PGM? 1 = YES 0 = NO For defining output relay functions. 0 For entering voice descriptors for relays to be used with the 4285/4286 VIP Module. RLY VOICE DESCR? 1 = YES 0 = NO 0 CUSTOM INDEX ? 1 = YES 0 = NO 0 ACCESS POINT PGM 1 = YES 0 = NO 0 ACCESS GRP PGM 1 = YES 0 = NO 0 For creating custom word substitutes for VIP Module annunciation. EVENT/ACTION PGM 1 = YES 0 = NO 0 SCHEDULED CHK-IN 1 = YES 0 = NO 0 For defining the parameters for each of the VistaKey access points, including which group(s) have access through an access point (door). See the VistaKey-SK Installation and Setup Guide for the detailed programming instructions. For defining the capabilities (privileges) for each group of users. See the VistaKey-SK Installation and Setup Guide for the detailed programming instructions. For defining events and time windows for an access group. See the VistaKey-SK Installation and Setup Guide for the detailed programming instructions. For defining the schedule for the system to automatically call the downloader. Zone Programming If using 5800 Series transmitters, do not the install batteries until you are ready to enroll them. After enrolling the transmitter, the battery need not be removed. This is to prevent enrolling the wrong serial number. PROMPT EXPLANATION ZONE PROG? 1 = YES 0 = NO 0 SET TO CONFIRM? 1 = YES 0 = NO ENTER ZONE NO. 000 = QUIT 0 010 Zone 010 entered ↑ Press 1 to enter ZONE PROGRAMMING mode. The following screens appear. Press [✱] to display the next screen. Press # to display a previous screen. This prompt appears once upon entering Zone Programming Mode. If “Yes,” Confirmation prompts will be displayed after the device’s Serial and Loop numbers have been entered later. Enter the 3-digit zone number to be programmed, as follows: Protection Zones = 001–250 Relay Zones = 601–632 ECP Device Supervisory Zones = 800–830 System Supervisory Zones = 988, 990, 992 (duress), 997 Keypad Panic Zones = 995, 996, 999 Press [✱] to continue. 010 ZT P RC In L 00 1 10 00 1 This display appears, showing a summary of the zone's current programming. ZT = Zone Type, P = Partition, RC = Report Code, In = the input type of device, and L = the device's loop number to which the sensor is connected. Some devices can support more than one zone by means of individual loops (for example, 5801, 5804, 5816, 5817, etc.). If the zone is not programmed, the display appears as shown here. If you are checking a zone's programming, and it is programmed satisfactorily, press [#] to back up one step and enter another zone number, if desired. Press [✱] to continue. – 15 – PROMPT EXPLANATION 010 ZONE TYPE PERIMETER Each zone must be assigned a zone type, which defines the way in which the system responds to faults in that zone. Refer to the Zone Type Definitions section in the VISTA-128BP/VISTA-250BP Installation and Setup Guide for detailed definitions of each zone type. Enter the zone type desired (or change it, if necessary). Available zone types are listed below. 03 Zone number 010 and Zone Type 03 entry shown † These are special zone types used with 5800 Series Wireless Pushbutton Units that result in arming the system in the STAY or AWAY mode, or disarming the system, depending on the selection made. 00 = Assign for Unused Zones 01 = Entry/Exit #1, Burglary 02 = Entry/Exit #2, Burglary 03 = Perimeter, Burglary 04 = Interior Follower, Burglary 05 = Trouble Day/Alarm Night 06 = 24 Hr. Silent Alarm 07 = 24 Hr. Audible Alarm 08 = 24 Hr. Auxiliary 09 = Fire Without Verification 10 = Interior Delay, Burglary 14 = Panel Link Supervision 16 = Fire With Verification 20 = Arm–STAY† 21 = Arm AWAY† 22 = Disarm† 23 = No Alarm Response (e.g., relay activation) 27 = Access Point 28 = MLB Supervision (if VGM installed) 29 = Momentary Exit (used with VistaKey module) Press [✱] to continue. 010 Arm w/ Fault? 1 = YES 0 = NO 0 010 Force Arming? 1 = YES 0 = NO 0 010 Vent zone ? 1 = YES 0 = NO 0 If you selected response type 1, 2, 4, or 10, this prompt appears. Enter 1 to enable arming of the partition with this zone faulted. The zone must be restored (see Force Arming, the next prompt) before the exit delay expires otherwise the system starts the entry delay and must be disarmed, or an alarm occurs. If you entered 1 (YES) at the previous prompt, this prompt appears. Enter 1 to enable the system to automatically bypass the zone if it is faulted at the end of the exit delay. If you enter 0 to disable and the zone is faulted at the end of exit delay, the system either performs the exit error logic, if field 1✱20 is enabled, or an alarm occurs. NOTE: Force Arming cannot be enabled for UL installations. If you selected response type 3, this prompt appears. Enter 1 to enable the arming of the partition with this zone faulted (force arm). The zone is automatically bypassed. Note: The zone may be unbypassed simply by restoring the zone (e. g.,closing the window), if the Vent Rearm option (next prompt) for the zone is enabled. Enter 0 to disable. Press [✱] to continue. 010 Vent Re-arm ? 1 = YES 0 = NO 1 If you entered 1 (YES) at the previous prompt, this prompt will appear. Enter 1 to enable the system to automatically unbypass the zone when it is restored (e.g., by closing the window). Enter 0 to disable. The zone is bypassed for the duration of the armed period regardless of the zone status. Press [✱] to continue. 010 STAY MODE None 0 If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear. Enter the STAY mode for this zone (0-2). 0 = None. The zone is not bypassed when the partition is armed STAY. 1 = Stay 1. The zone is automatically bypassed when the user enters [User Code] + [3] (STAY) + [1]. 2 = Stay 2. The zone is automatically bypassed when the user enters [User Code] + [3] (STAY) + [2]. Notes: 0 (None) cannot be selected for response types 4 and 10. Response types 4 and 10 are defaulted for STAY mode 1. If the user enters [User Code] + [3] (STAY) + [3], all zones assigned to Stay mode 1 and 2 in the partition are automatically bypassed. If none of the zones in the partition are assigned to Stay mode 2, then when the user enters [User Code] + [3] (STAY), all zones assigned to Stay mode 1 are automatically bypassed. Press [✱] to continue. 010 Auto-stay ? 1 = YES 0 = NO 0 If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear. Enter 1 to enable. The zone is automatically bypassed if none of the entry/exit zones are opened during the exit delay time (no one exits the premises). Enter 0 to disable. Notes: All zones enabled for auto-stay except types 3 and 5 have exit delay time when the partition is armed. If auto-stay is enabled, make sure at least one zone is programmed for entry/exit in the same partition, otherwise this zone will be automatically bypassed every time the partition is armed. Press [✱] to continue. – 16 – PROMPT EXPLANATION 010 Silent ? 1 = YES 0 = NO If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear. Enter 1 to enable. The zone follows all the selected response type’s characteristics, except in the alarm condition, the alarm output and the keypad sounder do not sound and the keypad does not display the alarm condition. Enter 0 to disable. 1 Press [✱] to continue. 010 Bypass Group 01-15 01 If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear. Enter the bypass group for the zone (01–15). This enables the user to bypass a group of zones by entering [User Code] + [6] (Bypass) + [✱] + [Group No.] (01-15). Enter 00 for None. Press [✱] to continue. If response type 27, or 29 was selected, this prompt will be displayed. Enter the access point to be controlled by the input type (00-31 for type 27; 01-15 for type 29). Note: If you are using the VistaKey module, the access point must match the address that was set in the module. 010 ACCESS POINT (00-31) 01 Press [✱] to continue. 010 ENTRY OR EXIT 0 If response type 27, or 29 was selected selected, this prompt will be displayed. Enter whether the access point is an entry or exit point. 0 = entry; 1 = exit Press [✱] to continue. 010 Panel ID# (01-08) If you selected response type 14, this prompt appears. Enter the panel ID#. This ID # must match the ID # programmed in Device Programming. 01 Press [✱] to accept entry. Enter the partition number (1–8) you are assigning this zone to. 010 Partition 1 010 REPORT CODE 1st 03 2nd 12 3C Press [✱] to continue. Enter the report code. The report code consists of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. For example, for a report code of "3C," enter 03 for "3" and 12 for "C." (Refer to the System Communication section in the Installation and Setup Guide for more information about report codes and reporting formats.) Press [✱] to continue. 010 INPUT TYPE RF Xmitter 3 Input types 4 & 5 are valid for certain 5800 Series transmitters only (e.g., 5801, 5802, 5802CP & 5803). If using input type 02 with a door/window type transmitter, only loop 1 may be used. Input type 10 is applicable only if PassPoint ACS is installed with the VISTA Gateway Module. If you selected response type 14, 28, or 29 the input type MUST be 00. Enter the input device type as follows: 00 = not used 01 = hardwired 02 = RF motion (RM type) 03 = supervised RF transmitter (RF type) 04 = unsupervised RF transmitter (UR type) 05 = RF button-type transmitter (BR type) 06 = serial number polling loop device (SL type) 07 = DIP switch-type polling loop device 08 = right loop of DIP switch type device 09 = keypad input (code + #73) 10 = PassPoint ACS input 11 = VistaKey Door Status Monitor (DM) 12 = VistaKey Request to Exit (RE) 13 = VistaKey General Purpose (GP) Right loops refer to the use of the right loop on a 4190WH Zone Expander Module and/or 4278 PIR, which allow hardwired devices to be monitored by the polling loop. If you are programming hardwired or DIP switch polling loop devices, the summary display appears after completing this entry. NOTE: Input types 11 (DM), 12 (RE), and 13 (GP) should only be used with VistaKey modules. Press [✱] to continue. – 17 – PROMPT EXPLANATION 001 Tamper Option none If you selected input type 1, 6, 7, or 8, this prompt displays. If the zone has a tamper switch wired in the loop in addition to a sensor contact, enter the tamper option. Enter 1 if the tamper switch is normally closed (wired in series) with the EOL resistor. Enter 2 if the tamper switch is normally open (wired in parallel) with the EOL resistor. Enter 0 if a tamper switch is not being used in the loop. NOTE: For zone response types 9 or 16 (Fire), the tamper selection must be “0” none. 0 If you selected input type 6, this prompt displays. Enter 1 if using a 4101SN Relay Module for this zone. Otherwise enter 0. 010 V-PLEX RELAY? 1 = YES 0 = NO Press [✱] to continue. 010 CONS ECP ADDR (00-30) 01 010 ACS ZONE # (00-31) 01 If you selected input type 09, this prompt displays. Enter the ECP address of the keypad that is being used for entry/exit for this access point (00-30). Press [✱] to continue. If you selected input type 10, this prompt displays. Enter the PassPoint ACS zone ID that this VISTA zone maps to (00-31). Press [✱] to continue. If you selected input types 06, or 11 – 13, this prompt displays. Enter the access point (01-15) to be controlled by the input type. Note: For input type 06, the selected address must be 00. Note: If you are using the VistaKey module, the access point must match the address that was set in the module. 010 ACCESS POINT (01-15) 01 Press [✱] to continue. 010 INPUT S/N: AXXX-XXXX L 1 For Serial Number entry and Loop Number entry, do one of the following: a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and release the button, wait approximately 4 seconds, then press and release the button a second time. OR b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the Alpha keypad. Then press the [✱] key, the cursor moves to the “L” position. You can edit the loop number, if necessary. When the loop number is acceptable, press [✱]. OR c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several input loops). Press [✱] to accept. 010 INPUT S/N: A022-4064 L 1 The cursor will then move to the Loop column (L) with the previously entered/transmitted serial number displayed. Enter the loop number (refer to 5800 Series Transmitters Loop Designations below). To Delete an Existing Serial Number, enter “0“ in the loop number field. The serial number will change to “0”s. If “0” was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display. Press [✱] to accept. 010 INPUT S/N: A022-4064 L 1 The system will then check for a duplicate serial/loop number combination. If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and display the serial number along with a “?” for the loop number, allowing you to re-enter the correct loop number. If the serial/loop number combination is not a duplicate in the system, a display appears showing the serial number and loop number entry. Press [✱] to continue. – 18 – 5800 Series Transmitters Loop Designations LOOP 3 LOOP 2 (REED) LOOP 1 (PRIMARY) LOOP 2 LOOP 2 (AUX. CENTER) LOOP 1 LOOP 1 LOOP 4 YOU MUST ENROLL THIS BUTTON 5801 ENROLL AS "UR" OR "RF" LOOP 1 (TERMINALS) ALTERNATE POSITION FOR LOOP 2 5802MN ENROLL AS "UR" OR "RF" LOOP 2 (REED) LOOP 2 (REED) LOOP 2 LOOP 4 LOOP 1 LOOP 1 (TERMINALS) LOOP 2 YOU MUST ENROLL THIS BUTTON LOOP 4 LOOP 1 (INTERNAL SHOCK SENSOR) LOOP 3 (TERMINALS) LOOP 3 (TERMINALS) 5819 ENROLL AS "RF" LOOP 1 5819S (WHS & BRS) ENROLL AS "RF" LOOP 3 •• •••••••• •• •• •• • •• 5804 ENROLL AS "BR" 5817 ENROLL AS "RF" 5816MN ENROLL AS "RF" LOOP 3 YOU MUST ENROLL THIS BUTTON LOOP 3 (AUX. RIGHT) SET HOUSE CODE 5827 SET HOUSE CODE 5827BD SET HOUSE CODE 5804BD ENROLL AS "BR" LOOP 1 5809 ENROLL AS "RF" LOOP 2 (REED) LOOP 1 (MOTION) LOOP 1 5808 ENROLL AS "RF" LOOP 1 (TERMINALS) 5816 ENROLL AS "RF" (Green) (Red) (Yellow) 5850 (GBD) ENROLL AS "RF" 5890 ENROLL AS "RF" 5800_trans_loop-V0 Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc. UL The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD, and 5850 transmitters are not intended for use in UL installations. PROMPT EXPLANATION XMIT TO CONFIRM Confirmation Option: This prompt only appears if you answered “Yes” at the first prompt. The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [✱] key on the keypad to save the serial and loop number combination without confirming. PRESS ✱TO SKIP Entd Rcvd A022-4063 A022-4064 010 ZT P RC In L 03 1 3C RF 1s 1 If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it is also displayed. If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter or transmit the correct serial number. If the serial number transmitted does match the serial number entered, the system beeps 3 times and a summary display appears, showing that zone’s programming. Note that an “s” indicates that a transmitter’s serial number has been enrolled. Press [✱] to accept the zone information. – 19 – PROMPT EXPLANATION ENTER ZONE NO. 000 = QUIT 011 The system now returns to the “ENTER ZONE NO.” prompt for the next zone. When all zones have been programmed, enter “000” to quit. After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device. When you have finished programming all zones, test each using the system's Test Mode. Do not use the Transmitter ID Sniffer Mode. The system checks only for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop, and also does not verify polling loop type zones. Expert Mode Zone Programming Expert mode allows you to program zones using the minimum number of screens and keystrokes. Expert Mode Zone Programming does not provide the capability to program some of the zone’s attributes, such as Arm w/Fault, Vent Zone, STAY mode, Auto-STAY, Bypass Group, etc. If you want to program a zone for any of these attributes, you must use Zone Programming. Enter the Programming mode with [Installer Code] + 8 0 0 0 Before programming your zones, do the following: 1. Program field 2✱00: Number of Partitions. 2. Enable your RF Receiver in Device Programming menu mode. To program your zones, press ✱93 to display the "ZONE PROG?" prompt. Enter “0” (NO) to each prompt until the “EXPERT MODE?” prompt appears. PROMPT EXPLANATION EXPERT MODE? 1 = YES 0 = NO Press 1 to enter Expert mode. 0 SET TO CONFIRM? 0 = NO 1 = YES 0 Zn ZT P RC In 001 03 1 10 HW L - Zn ZT P RC In L 010 03 1 10 RF 1s This prompt appears once upon entering Expert Mode. If you select “Yes,” Confirmation prompts will be displayed after the device’s Serial and Loop numbers have been entered later. A summary display appears, showing zone 1’s current programming or default values. Enter the desired 3-digit zone number and press [✱]. Note: If you want to exit the Expert mode, enter “000” + [✱]. If an “s” appears after the loop number, it indicates that the transmitter’s serial number has been enrolled. Use the [D] key to enter and duplicate wireless keys (see “Entering Wireless Keys” later) – 20 – PROMPT EXPLANATION Zn ZT P RC In L 010 03 1 10 RF - Enter all zone information except for Loop number, or press “C” to copy the zone information on this screen from the last saved zone (including Loop). ZT = Zone Type P = Partition RC = Report Code In = Input Device Type L = Loop number to which the sensor is connected. NOTE: Pressing the [C] copies the zone information from the last saved zone, which includes the input type. Verify this information is correct for this zone. On this screen: • • Use the [A] key to move to the right. Use the [B] key to move to left and to back up to “ZT” field. Press [✱] to accept the existing or newly-entered zone information. Enter the remainder of the zone’s information, or press the [C] key to copy the zone attributes on this screen from the last saved zone. B = Not Applicable M = Not Applicable V = V-plex Relay? (only used if “In” = 6) AC = Access Point (only used if ZT = 27, 29 or In = 6, 11, 12, 13) E = Entry or Exit? (only used if ZT = 27) AD = Address (only used if “In” = 9 or 10) If “In” = 9, enter the Device Address If “In” = 10, enter the PassPoint Zone Number NOTE: Pressing the [C] copies the zone attributes from the last saved zone. Verify the attributes for this zone are correct. On this screen: ZN B M V A C E AD 010 − − 1 0 1 1 01 • • Use the [A] key to move to the right. Use the [B] key to move to left and to back up to “V” field. Press [✱] to accept existing information. 010 INPUT S/N: A XXX-XXXX If you entered RM, RF, BR, UR or SL for the Input Type, this screen displays. Otherwise the summary screen for the next zone displays. Enter the 7-digit serial number, using one of the following methods: a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and release the button, wait approximately 4 seconds, then press and release the button a second time. OR b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the alpha keypad. Then press the [✱] key, the cursor will move to the “L” position. You can edit the loop number, if necessary. When the loop number is acceptable, press [✱]. OR c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several input loops). Remember, you can use the [A] key to move to the right or the [B] key to move to the left. You can also use the [#] key to back up without saving. L - 010 INPUT S/N: A022-4064 L 1 Press [✱] to accept the serial number and advance to the “L” position (if method “a” or “c” was used), then enter the loop number. If necessary, press the [#] key to back up without saving, and re-enter or edit the serial number before pressing [✱] to save The system checks for a duplicate. If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and display the serial number along with a “?” for the loop number, allowing you to re-enter the correct loop number. 010 INPUT S/N: A000-0000 L 1 To Delete an Existing Serial Number, enter “0“ in the loop number field. The serial number will change to “0”s. If “0” was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display. – 21 – PROMPT EXPLANATION XMIT TO CONFIRM The prompt to confirm appears. This prompt only appears if you answered “Yes” at the “SET TO CONFIRM?” prompt. The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [✱] key on the keypad to save the serial and loop number combination without confirming. PRESS ✱TO SKIP Entd Rcvd Zn 011 A022-4063 A022-4064 ZT 00 P 1 RC 10 1 In L 00 1 If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it also is displayed. If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display for the next zone does not appear), press the [#] key twice and then enter or transmit the correct serial number. Activate the button on the wireless key again after re-entering the serial number. If the serial number transmitted matches the serial number entered, the system beeps 3 times and advances to the summary display for the next zone's programming. After all the zones have been programmed, enter 000 for the zone number to quit. After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device. Entering Wireless Keys If you pressed the D key previously to enter defaults for 5804 and/or 5804BD wireless keys, the following screens appear: PROMPT EXPLANATION Enter template number (1–6). 1–3 = 5804 templates; 4–6 = 5804BD templates. See the defaults provided for each template in the chart that follows these procedures. FROM TEMPLATE 1–6 1 Select from templates. Press [✱] to display template (template 1 shown selected). Note: If necessary, press [#] to back up and re-enter template number. Press [#] if you want to return to zone attributes screen. L 01 02 03 04 ZT 23 22 21 23 1 When you press [✱], the selected template is displayed. Top line of display represents loop numbers; bottom line represents zone type. Press [✱] to accept template. Enter partition number for wireless key. PARTITION Press [✱] to continue. 1 The system searches for the highest available, consecutive 4-zone group (the four zones required for the 5804 and 5804BD), and displays the lowest zone number of the group. ENTER ZONE NO 000 = QUIT 024 ▲ Example of zone number suggested by the system. This indicates that zones 24, 25, 26, and 27 are available. 024 INPUT S/N AXXX-XXXX L 1 If you want to start at a different zone number, enter the zone desired and press [✱]. If that zone number is displayed, the system has the required number of consecutive zones available, beginning with the zone you entered. If not, the system again displays a suggested zone that can be used. If the required number of consecutive zones is not available at all, the system will display “000.” Press [✱] to accept. To enter the serial number: Press and release a button on the wireless key. OR Manually enter the 7-digit serial number printed on the device’s label. Press [✱] to accept serial number. The system checks for a duplicate. If a duplicate exists, a long error beep will sound and the serial number reverts back to all “X”s allowing you to re-enter the serial number. Use the [A] key to move forward within the screen, and the [B] key to back up. – 22 – PROMPT EXPLANATION XMIT TO CONFIRM If you entered YES previously at the SET TO CONFIRM prompt (see first prompt following entry into the Expert Programming Mode), the display on the left appears. To confirm, activate the button on the wireless key that corresponds to this zone. PRESS ✱TO SKIP Entd Rcvd If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key and then enter the correct serial number. Activate the button on the wireless key again after re-entering the serial number. A022-4063 A022-4064 ENTER ZONE NO 000 = QUIT 028 If the serial number transmitted matches the serial number entered, the system will beep 3 times and revert to the "Start Zone No." prompt and will show the lowest numbered zone of the next available 4-zone group (4 consecutive zones) that is available for programming. After all the wireless keys have been entered, enter 000 for the zone number to quit. After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device. Wireless Key Default Templates 5804 Template 1 Template 2 Template 3 5804BD Loop 1 2 3 4 Loop 1 2 3 4 Loop 1 2 3 4 Function No Response Disarming Arm AWAY No Response Function No Response Disarming Arm AWAY Arm STAY Function 24-Hour Panic Disarming Arm AWAY Arm STAY Zone Type 23 22 21 23 Zone Type 23 22 21 20 Zone Type 07 22 21 20 Template 4 Template 5 Template 6 – 23 – Loop 1 2 3 4 Loop 1 2 3 4 Loop 1 2 3 4 Function No Response No Response Arm AWAY Disarming Function No Response Arm STAY Arm AWAY Disarming Function 24-Hour Panic Arm STAY Arm AWAY Disarming Zone Type 23 23 21 22 Zone Type 23 20 21 22 Zone Type 07 20 21 22 Report Code Programming All report codes are entered using #93 Menu Mode Programming, either through Report Code Programming, or through Zone Programming while entering other zone information. In the VISTA-128BP/VISTA-250BP, reports are divided into six categories. These categories represent the main menu options in Report Code Programming. Reports and the categories in which they are found are as follows: ALARM CODES Zone Alarm Reports SYSTEM GROUP #2 Arm STAY Time Set, Log Reset Log 50%, 90% Full Event Log Overflow Exit Error by Zone Exit Error by User Recent Close RESTR, SUPV. CODES (for groups of 16 zones) Alarm Restore Trouble Trouble Restore Bypass Bypass Restore SYSTEM GROUP #1 SYSTEM GROUP #3 Early Open Early Close Late Open Late Close Failed to Open Failed to Close Auto-Arm Failed Schedule Change SYSTEM GROUP #4 Walk-Test Start Walk-Test End Closing (arm AWAY) Opening (disarm) System Low Battery Low Battery Restore AC Loss AC Restore Periodic Test Power Cancel Program Tamper The programming sequence that follows assumes that you will be entering all reports for the system at one time. In actuality, you may skip from one main menu option to another by pressing 0 (N) at each main menu option. To enter report codes, do the following: Enter Program Mode: [Installer Code] + 8 0 0 0. Then press #93. Enter 0 (N) at each main menu option until the Report Code Programming option is displayed. PROMPT EXPLANATION REPORT CODE PROG 1 = YES 0 = NO 0 Press 1 (Y) to enter to Report Code Programming. Zone Alarm Reports PROMPT EXPLANATION ALARM, ID DIGIT? 1 = YES 0 = NO Press [1] (Y) to enter Alarm Report Codes for zones. Press [0] (N) to skip to the next main menu option. 0 ENTER ZONE NO. 000 = QUIT 001 Enter the zone number for which you are entering the report code. 001 REPORT CODE 1st 00 2nd 00 00 Enter the first digit of the Alarm report code (double-digit entry) and press [✱]. Enter the 2nd digit of the Alarm Report code. Press [✱] to continue. Press [✱] to continue. ENTER ZONE NO. 000 = QUIT 001 Enter the zone number for which you are entering the report code. When all zone Alarm Codes have been programmed, enter 000 to Quit. QUIT REPORT MENU 1 = YES 0 = NO 0 If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming. If you wish to enter other system report codes, enter 0 (N). Press [✱] to continue. Press [✱] to continue. – 24 – Restore/Supervisory Codes PROMPT EXPLANATION RESTR, SUPV. CODE 1 = YES 0 = NO 0 Press [1] (Y) to enter Restore and Supervisory Codes for zones. ENTER ZN FOR GRP 000 = QUIT 001 Enter one zone for each group of 16 zones (001-016, 017-032, etc.). ALARM RESTORE GRP 001-016 00 Enter the first digit of the Alarm Restore Report Code for this group of zones (double-digit entry). The second digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for each zone (if programmed). Press [✱] to continue. TROUBLE GRP 001-016 00 Enter the first digit of the Trouble Report Code for this group of zones (double-digit entry). The second digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for each zone (if programmed). Press [✱] to continue. TROUBLE RESTORE GRP 001-016 00 Enter the first digit of the trouble restore code (single-digit entry) and press [✱]. The second digit (for twodigit reporting formats) is automatically the ID (second) digit of the alarm report code for each zone (if programmed). Press [✱] to continue. BYPASS GRP 001-016 00 Enter the first digit of the Bypass Report Code (double-digit entry) and press [✱]. The second digit (for twodigit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for each zone (if programmed). Press [✱] to continue. BYPASS RESTORE GRP 001-016 00 Enter the first digit of the Bypass Restore Report Code (double-digit entry) and press [✱]. The second digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for each zone (if programmed). Press [✱] to continue. ENTER ZN FOR GRP 000 = QUIT 017 QUIT REPORT MENU 1 = YES 0 = NO 0 Enter one zone for each group of 16 zones. When you are finished entering Restore and Supervisory Codes for all zone groups, enter 000. Press [✱] to continue. If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming. If you wish to enter other system report codes, enter 0 (N). Press [✱] to continue. System Group #1 Codes PROMPT EXPLANATION SYSTEM GROUP #1? 1 = YES 0 = NO 0 To enter System Group #1 codes, press 1 (Y). CLOSE 1st 00 Enter the first digit of the Closing (Arm-AWAY) report. Press [✱]. Enter the second digit of the report. If the user number is desired as the second digit, enter 01 (not necessary for Contact ID or High Speed formats). 2nd 00 Press [✱] to continue. – 25 – PROMPT EXPLANATION Enter the rest of the codes in the same manner. Other report codes in System Group #1 are: Opening (Disarm) Also, enable this if you desire Callback Requested reports (the panel answers a • phone call from the downloader). System Low Battery • Low Battery Restore • AC Loss • AC Restore • Periodic Test • Power • Cancel • Program Tamper • Once you have entered these report codes, the system prompts you with the Quit menu. QUIT REPORT MENU 1 = YES 0 = NO 0 If you have completely finished entering report codes, press 1 (Y) to quit Report Code Programming. If you wish to enter other system report codes, enter 0 (N). Press [✱] to continue. System Group #2 Codes PROMPT EXPLANATION SYSTEM GROUP #2 ? 1 = YES 0 = NO 0 To enter System Group #2 codes, press [1] (Y). STAY 1st 00 Enter the first digit of the Arm-STAY report. Press [✱]. Enter the second digit of the report. If the user number is desired as the second digit, enter 01 (not necessary for Contact ID or High Speed formats). 2nd 00 Press [✱] to continue. Enter the rest of the codes in the same manner. Other codes in System Group #2 are: Time Set, Log Reset • Log 50%, 90% Full • Event Log Overflow • Exit Error by Zone • Exit Error by User • Recent Close • Once you have entered these report codes, the system prompts you with the Quit menu. QUIT REPORT MENU 1 = YES 0 = NO 0 If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming. If you wish to enter other system report codes, enter 0 (N). Press [✱] to continue. System Group #3 Codes PROMPT EXPLANATION SYSTEM GROUP #3 ? 1 = YES 0 = NO 0 To enter System Group #3 codes, press [1] (Y). EARLY OPEN 1st 00 2nd 00 Enter the first digit of the Early Opening Report Code. Press [✱]. Enter the second digit of the report code. If the user number is desired as the second digit, enter 01 (not necessary for Contact ID or High Speed formats). Press [✱] to continue. – 26 – PROMPT EXPLANATION Enter the rest of the codes in the same manner. Other codes in System Group #3 are: Early Close • Late Open • Late Close • Failed to Open • Failed to Close • Auto-Arm Failed • Schedule Change • Once you have entered these report codes, the system prompts you with the Quit menu. QUIT REPORT MENU 1 = YES 0 = NO 0 If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming. If you wish to enter other system report codes, enter 0 (N) Press [✱] to continue. System Group #4 Codes PROMPT EXPLANATION SYSTEM GROUP #4 ? 1 = YES 0 = NO 0 To enter System Group #4 codes, press [1] (YES). WALK TEST START 1st 00 2nd 00 Enter the first digit of the Walk Test Start Report Code. Press [✱]. Enter the second digit of the report code. Press [✱] to continue. Enter the rest of the codes in the same manner. Other codes in System Group #4 are: Walk-Test End. • Once you have entered these report codes, the system prompts you with the Quit menu. QUIT MENU MODE? 1 = YES 0 = NO 0 Enter 1 to exit back to normal Programming mode. Enter 0 to stay in Menu mode. Alpha Descriptors Programming You can program a user-friendly English language description/location for all protection zones, relays, keypad panics, polling loop short, and RF receiver supervision troubles. Each description can be composed of a combination of words (up to 3) that are selected from a vocabulary of 244 words stored in memory, and any word can have an "s" or " 's " added to it. NOTE: Due to the use of 3-digit zone numbers, the first word of the descriptor is limited to 6 characters if you want it to fit on the top line of the display. In addition, up to 60 installer-defined words can be added to those already in memory. Thus, when an alarm or trouble occurs in a zone, an appropriate description for the location of that zone will be displayed at the keypad. A custom installer's message can be programmed for each partition which is displayed when the system is "Ready" (e.g., THE PETERSONS’). 1. To program alpha descriptors, enter Programming mode, then press #93 to display "ZONE PROG?" 2. Press [0] (NO) twice to display "ALPHA PROG?". 3. Press [1] to enter Alpha Programming. There are 6 submenu selections that will be displayed one at a time. Press [1] to select the mode desired. – 27 – Press [0] to display the next mode available. The alpha menu selections are: 4. ZONE DESCRIP? For entering zone descriptors. DEFAULT SCREEN? For creating custom message; displayed when system is ready. CUSTOM WORD? For creating custom words for use in descriptors. PART DESCRIP? For creating 4-character partition names. EXIT EDIT MODE? Press [1] to exit back to #93 Menu Mode. Refer to the sections that follow for procedures for adding alpha descriptors. Zone Descriptors 1. Select ZONE DESCRIPTOR mode. The keypad keys perform the following functions: [3] Scrolls both alphabet and actual words in ascending alphabetical order. [1] Scrolls both alphabet and actual words in descending alphabetical order. [2] Adds or removes an "s" or " 's " to a vocabulary word. [6] Switches between alphabet and actual word list; used to accept entries. [8] Saves the zone description in the system's memory. [#] [#] plus zone number displays the description for that zone. 2. Enter the zone number to which you want to assign a descriptor. 3. For example, key [✱] 001 to begin entering the description for Zone 1, (key [✱] 002 for Zone 2, [✱] 003 for Zone 3, etc.). The following is displayed: ✱ ZN 001 A. Note that the first letter of the alphabet appears after the zone number, and that the zone number is automatically included with the description. Enter the descriptor for that zone. Use one of two methods as follows: (Assume, for example, that the desired description for Zone 1 is BACK DOOR.) a) Press [#] followed by the 3-digit number of the first word from the fixed dictionary shown later in this section (e.g., [0][1][3] for BACK). Press [6] in order to accept the word and proceed, or press [8] to store the complete descriptor and exit; or b) Select the first letter of the desired description (note that "A" is already displayed). Use the [3] key to advance through the alphabet and the [1] key to go backward. Press [3] key repeatedly until "B" appears (press [1] to go backwards if you happen to pass it), then press [6] to display the first available word beginning with “B”. Press [3] repeatedly to advance through the available words until the word “BACK” is displayed. To add an "s" or " 's," if you need to, press 2. The first depression adds an "s," the second depression adds an " 's, " the third depression displays no character (to erase the character), the fourth depression adds an "s," etc. 4. 5. 6. Accept the word. To accept the word, press [6], which switches back to the alphabet list for the next word, or press [8] to store the complete descriptor and then exit. Select the next word. For selection of the next word (DOOR), repeat step 3a (word #057) or 3b, but selecting the word "DOOR.” To accept the word, press [6], which again switches back to alphabet list. Store the descriptor. When all desired words have been entered, press [8] to store the description in memory. To review the zone descriptors, key [#] plus zone number (e.g., #001). To edit zone descriptors, key [✱] plus zone number (e.g., ✱001) – 28 – 7. Exit Zone Description Mode: enter 000. Default Screen (Custom Message Display) Normally, when the system is in the disarmed state, the following display is present on the keypad. ****DISARMED**** READY TO ARM Part or all of the above message can be modified to create a custom installer message for each partition. For example, “****DISARMED****” on the first line or “READY TO ARM” on the second line could be replaced by the installation company name or phone number for service. Note: There are only 16 character spaces on each of the two lines. To create a custom display message, proceed as follows: 1. Select Default Screen mode. The keypad asks for the partition number for this message. Enter the partition number. Press [✱] to accept entry. The following display appears: ****DISARMED**** READY TO ARM 2. 3. 4. A cursor is present at the extreme left of the first line (over the first "star"). Press [6] to move the cursor to the right and [4] to move the cursor to the left. Press [7] to insert spaces or erase existing characters. Create the message. For example, to replace “READY TO ARM” with the message “SERVICE 424-0177,” proceed as follows: Press [6] to move the cursor to the right, and continue until the cursor is positioned over the first location on the second line. Press [3] to advance through the alphabet to the first desired character (in this case, "S"). Press [1] to go backward, when necessary. When the desired character is reached, press [6]. The cursor then moves to the next position, ready for entry of the next character (in this example, "E"). When the cursor reaches a position over an existing character, press [3] or [1] to advance or back up from that character in the alphabet. Proceed in this manner until all characters in the message have been entered. Save the message. Store the new display message in memory by pressing [8]. The system asks for a new partition number. Enter 0 to quit or 1-8 for a new partition number. Custom Words Up to 60 installer-defined words can be added to the built-in vocabulary. Each of the 60 "words" can actually consist of several words, but bear in mind that a maximum of 10 characters can be used for each word string. 1. Select CUSTOM WORD Mode. The keys perform the following functions: [3] Advances through alphabet in ascending order. [1] Advances through alphabet in descending order. [6] Selects desired letter; moves the cursor 1 space to the right. [4] Moves the cursor one space to the left. [7] Inserts a space at the cursor location, erasing any character at that location. [8] Saves the new word in the system's memory. [✱] Returns to Description Entry Mode. 2. Enter the custom word number (01-60) you want to create. For example, if you are creating the first word (or word string), enter 01; when creating the second word, enter 02, and so on. A cursor now appears at the beginning of the second line. 3. Type the word using one of two methods as follows: a) Press [#], followed by the 2-digit entry for the first letter you would like to display (e.g., 65 for "A"). When the desired character appears, press [6] to select it. The cursor will then move to the right, in position for the next character. Press [#] plus the 2-digit entry for the next letter of the word. or b) Press 3 to advance through the list of symbols, numbers, and letters. Press 1 to move back through the list. When you have reached the desired character, press [6] to select it. The cursor then moves to the right, in position for the next character. – 29 – 4. 5. 6. 7. Repeat step 3 to create the desired custom word (or words). Press [4] to move the cursor to the left if necessary. Press [7] to enter a blank (or to erase an existing character). Each word or word string cannot exceed 10 characters. Save the word by pressing [8]. This returns you to the “CUSTOM WORD?” display. The custom word (or string of words) is automatically added to the built-in vocabulary at the end of the group of words beginning with the same letter. Custom words are retrieved as word numbers 245 to 304 for words 1 to 60, respectively, when using method 3a to enter alpha descriptors. When using method 3b to enter alpha descriptors, each word appears at the end of the group of words that begin with the same letter as it does. Repeat steps 2 through 6 to create up to a maximum of 60 custom words (or word strings). Exit Custom Word Mode by entering 00 at the “CUSTOM WORD” prompt. Partition Descriptors 1. Select "Part DESCRIPT." Mode. The system asks for the partition number desired. Enter the number as a single-key entry 1-8. 2. Follow the same procedure as for custom words. Note: The partition descriptors are limited to 4 characters (e.g., WHSE for warehouse). – 30 – Alpha Descriptor Vocabulary (For entering alpha descriptors. To select a word, press [#] followed by the word's 3-digit number.) NOTE: This vocabulary is not to be used for relay voice descriptors. See the Relay Voice Descriptors section when programming relay voice descriptors. 000 (Word Space) • 001 AIR • 002 ALARM ✳ 003 ALCOVE 004 ALLEY 005 AMBUSH • 006 AREA • 007 APARTMENT 008 ART • 009 ATTIC ✳ 010 AUDIO 011 AUXILIARY • 052 DETECTOR ✳ • 053 DINING ✳ 054 DISCRIMINATOR 055 DISPLAY 056 DOCK • 057 DOOR ✳ 058 DORMER • 059 DOWN • 060 DOWNSTAIRS 061 DRAWER • 062 DRIVEWAY 063 DRUG • 064 DUCT • 012 BABY ✳ • 013 BACK ✳ • 014 BAR 015 BARN • 016 BASEMENT ✳ • 017 BATHROOM ✳ • 018 BED • 019 BEDROOM ✳ 020 BELL • 021 BLOWER • 022 BOILER 023 BOTTOM 024 BOX 025 BREAK • 026 BUILDING 027 BURNER 028 • 029 030 031 032 033 034 035 036 • 037 038 039 • 040 041 042 043 044 045 • 046 047 CABINET CALL CAMERA CAR CASE CASH CCTV CEILING CELLAR CENTRAL CIRCUIT CLIP CLOSED ✳ COIN COLD COATROOM COLLECTION COMBUSTION COMPUTER CONTACT • 048 049 • 050 051 DAUGHTERS DELAYED DEN ✳ DESK • 065 066 067 068 • 069 070 • 071 072 EAST ELECTRIC EMERGENCY ✳ ENTRY EQUIPMENT EXECUTIVE EXIT ✳ EXTERIOR • 073 074 075 • 076 • 077 078 • 079 • 080 081 082 • 083 084 • 085 086 087 FACTORY FAILURE FAMILY FATHERS FENCE FILE FIRE ✳ FLOOR ✳ FLOW FOIL FOYER FREEZER FRONT ✳ FUR FURNACE 088 • 089 • 090 091 • 092 093 094 GALLERY GARAGE ✳ GAS GATE GLASS GUEST GUN ✳ 102 INTERIOR 103 INTRUSION 104 JEWELRY • 105 KITCHEN ✳ • 106 LAUNDRY ✳ • 107 LEFT 108 LEVEL • 109 LIBRARY ✳ • 110 LIGHT 111 LINE 112 LIQUOR • 113 LIVING ✳ • 114 LOADING 115 LOCK 116 LOOP 117 LOW • 118 LOWER • 119 120 121 122 • 123 124 • 125 126 127 128 129 • 130 • 131 132 133 MACHINE MAGNETIC MAIDS MAIN ✳ MASTER ✳ MAT MEDICAL ✳ MEDICINE MICROWAVE MONEY MONITOR MOTHERS MOTION ✳ MOTOR MUD 154 QUAD 155 • 156 157 158 159 160 • 161 • 162 163 SAFE SCREEN SENSOR SERVICE SHED ✳ SHOCK SHOP ✳ SHORT SHOW SIDE ✳ SKYLIGHT SLIDING ✳ SMOKE ✳ SONIC SONS SOUTH SPRINKLER STAMP STATION STEREO STORE STORAGE ✳ STORY STRESS STRIKE SUMP SUPERVISED ✳ SUPERVISION SWIMMING SWITCH 194 195 196 197 198 • 199 200 TAMPER TAPE TELCO TELEPHONE TELLER TEMPERATURE THERMOSTAT • • • • • • • • • 095 HALL ✳ • 096 HEAT 097 HIGH 098 HOLDUP 099 HOUSE ✳ 100 INFRARED • 101 INSIDE ✳ OFFICE ✳ OIL OPEN ✳ OPENING OUTSIDE OVERFLOW OVERHEAD 143 • 144 145 • 146 147 • 148 149 150 PAINTING PANIC ✳ PASSIVE PATIO ✳ PERIMETER PHONE PHOTO POINT RADIO REAR RECREATION REFRIG REFRIGERATION RF RIGHT ROOM ✳ ROOF 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 • 134 NORTH 135 NURSERY • 136 137 • 138 139 • 140 141 142 • 201 TOOL 202 TRANSMITTER 203 TRAP 151 POLICE ✳ 152 POOL ✳ • 153 POWER • • • • • 204 205 206 207 208 209 210 211 212 213 214 215 • 216 • 217 218 • 219 220 221 ULTRA UP UPPER UPSTAIRS ✳ UTILITY VALVE VAULT VIBRATION VOLTAGE WALL WAREHOUSE WASH WEST WINDOW ✳ WINE WING WIRELESS WORK 222 XMITTER 223 YARD 224 ZONE (No.) • 225 ZONE ✳ • • • • • • • • • • • • • • • • • • • 0✳ 1✳ 1ST ✳ 2✳ 2ND ✳ 3✳ 3RD ✳ 4✳ 4TH 5✳ 5TH 6✳ 6TH 7✳ 7TH 8✳ 8TH 9✳ 9TH Custom Word 1 to 304 Custom Word 60 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 CHARACTER (ASCII) CHART 32 33 34 35 36 37 38 39 40 41 (space) ! " # $ % & ' ( ) 42 43 44 45 46 47 48 49 50 51 * + , . / 0 1 2 3 52 53 54 55 56 57 58 59 60 61 (For Adding Custom Words) 4 62 > 5 63 ? 6 64 @ 7 65 A 8 66 B 9 67 C : 68 D ; 69 E < 70 F = 71 G 72 73 74 75 76 77 78 79 80 81 H I J K L M N O P Q 82 83 84 85 86 87 88 89 90 R S T U V W X Y Z Notes: This factory-provided vocabulary of words is subject to change. Bulleted words in bold face type are those that are also available for use by the 4285/4286 VIP Module. If you are using a VIP Module, and words other than these are selected for alpha descriptors, the Voice Module will not provide annunciation of those words. Words italicized followed by an asterisk indicate those words supported by the 6160V Voice keypad. – 31 – Device Programming This menu is used to program keypads, receivers, and relay modules, etc. Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression options, and these settings cannot be changed. From Data Field Programming mode, press #93 to display "ZONE PROG?" Press [0] repeatedly to display "DEVICE PROG?" PROMPT EXPLANATION DEVICE PROG? 1=YES 0=NO Press [1] to enter Device Programming. DEVICE ADDRESS 01-30, 00=QUIT 0 01 The device address identifies the device to the control. Enter the 2-digit device address number to match the device's physical address setting (01-30). Notes: Device Address 01 is defaulted for an AUI (Symphony) with Keypad Global arm/disarm disabled. • Device Address 04 must be used for the 4285/4286 Voice Module, if one is utilized. If not, it can be • used for another device type. Device Address 24 must be used for TeleSmart, if one is utilized. If not, it can be used for another • device type. If using TeleSmart, you must program Device Address 23 as an alpha console. Do not connect an actual keypad set to address 23 to the control panel. This setup is necessary for remote access of TeleSmart. Press [✱] to accept entry. Select the type of addressable device as follows: DEVICE TYPE 00 00 = device not used 01 = alpha keypad (6139/6160, AUI) 03 = RF receiver (5881) 04 = output relay module (4204) 05 = voice (VIP) Module (4285/4286) 06 = long range radio 08 = fire display (FSA) 09 = Vista Gateway Module (VGM) 10 = panel link module 11 = Telesmart Press [✱] to accept entry. Alpha Keypad PROMPT EXPLANATION 01 CONSOLE PART. If you selected device type 01 (alpha keypad), this prompt appears. Enter the addressable device's default partition number (01 to maximum number of partitions programmed for system in field 2*00). This is the primary partition for the device. Enter 9 to make this keypad a "Master" keypad for the system. 1 Press [✱] to accept entry. 01 SOUND OPTION 00 If you entered device type 01 (alpha keypad), this prompt appears. Keypads can be individually programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode beeps. This helps prevent unwanted sounds from disturbing users in other areas of the premises. Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows: 00 = no suppression 01 = suppress arm/disarm & entry/exit beeps 02 = suppress chime mode beeps only 03 = suppress arm/disarm, entry/exit and chime mode beeps Press [✱] to accept entry. 01 KEYPAD GLBL? 0 If you entered device type 01 (alpha keypad), this prompt appears. Each keypad can give users with access to multiple partitions the ability to arm and disarm those partitions from it. To enable this keypad for global arming/disarming, enter 1. To prevent the ability to use this keypad for global arming/disarming, enter 0. Press [✱] to accept entry. – 32 – PROMPT EXPLANATION 01 AUI ? 1 = YES 0 = NO If you selected device type 01 (alpha keypad), this prompt appears. Enter 1 (YES) if the device is an AUI (Symphony 8112, 8122, 8132, or 8142). See the Symphony’s instructions for the installation and operation. 0 Press [✱] to accept entry. RF Expander PROMPT 01 RF EXPANDER HOUSE I EXPLANATION 00 If you selected device type 03 (RF receiver), this prompt appears. Enter the 2-digit House ID (00-31). This is required if you are using a wireless keypad (5827/5827BD). Press [✱] to accept entry. Output Relay Module PROMPT EXPLANATION 01 SUPERVISED CF? If you selected device type 04 (relay module), this prompt appears. Enter 1 if the unit is a 4204CF. If not, enter 0. If you enter 1, only Relay 1 (Output A) and Relay 3 (Output B) on each module may be programmed for functions. This module is usually used to add two additional supervised bell outputs to the system. 0 Press [✱] to accept entry. Long Range Radio If you selected device type 6, the 6139/6160 Keypad functions similarly to the 7720PLRR Programming Tool. See Figure 1 for the functions of the keys on the 6139. ARMED READY BS/ESC / N/Y A B C 1 2 3 D E F 4 5 6 S T 7 8 SPACE SHIFT * X 9 ENTER 0 # SHIFT function indicated by turning on READY LED. Figure 1: 6139 Key Functions for Programming 7820 Radio Each key has two possible functions: a normal function and a SHIFT function. To perform a normal key function, simply press the desired key. To perform a SHIFT key function, press SHIFT key, then press desired function key. Normal and SHIFT key Functions: Key Normal Key Function SHIFT Key Function BS/ESC [BS]: Press to delete entry [ESC]: Press to quit Program Mode Also, can reset EEPROM defaults * [↓]: Scroll down programming [↑]: Scroll up programming ↓/↑ N/Y [N]: Press for "NO" answer [Y]: Press SHIFT-Y for "YES" answer SHIF Press before pressing a SHIFT key function. Will light READY LED. LED goes out once a key is T pressed. Press again for each SHIFT function desired. 1/A [1]: For entering the number 1 [A]: Used for entering C.S. ID number 2/B [2]: For entering the number 2 [B]: Used for entering C.S. ID number 3/C [3]: For entering the number 3 [C]: Used for entering C.S. ID number 4/D [4]: For entering the number 4 [D]: Used for entering C.S. ID number 5/E [5]: For entering the number 5 [E]: Used for entering C.S. ID number 6/F [6]: For entering the number 6 [F]: Used for C.S. ID & FAST Mode 7/S [7]: For entering the number 7 [S]: Press to display diagnostic status 8/T [8]: For entering the number 8 [T]: Press to send TEST messages 9/X [9]: For entering the number 9 [X]: Press to reset the 7820 */SPACE [*]: Not used with 7820 [SPACE]: Not used with 7820 0 [0]: For entering the number 0 No SHIFT function #/ENTER [#/ENTER]: Press to accept entries No SHIFT function * Active only when the "REVIEW?" prompt is displayed. – 33 – The 6139/6160 Keypad displays the following prompts, which are sent by the Long Range Radio transmitter to the control. Note: These prompts are for the 7820 Radio only. If you are using a different radio, refer to the radio’s instructions for the correct prompts. PROMPT EXPLANATION DEVICE ADDRESS Enter the device address of the radio. The default address is 3. ID # Enter the 4-digit customer account number, 0001-9999. This ID number will appear in the messages generated by the radio. Messages generated by the panel and transmitted by the radio will contain the ID number programmed into the panel. The radio and the panel should have the same ID number, if possible. (1234) If a different 4-digit customer account number is used in the radio than is programmed into the alarm control, the radio will transmit radio-specific messages (power-on reset, AC fail, etc.) using the radio customer number, and alarm messages using the control panel’s customer number. If these numbers are different, you will be billed for two AlarmNet radio accounts. PROMPT EXPLANATION Enter Y for odd system flag; N for even system flag. ODD [Y/N] (N) Enter Y if this is an AlarmNet installation. Enter N if this is a private system and skip to Question 7. Alarmnet (Y/N) (Y) Enter the primary central station’s system ID number, 1-7F (will not be displayed for private system users). CS ID (11) Enter Y if optional battery will be used. Must be Y for UL installations (a battery must be installed). BAT PRESENT [Y/N] (N) USE RADIO # [Y/N] (N) 2ND CS ID (12) REVIEW (Y/N) (N) If you selected Y, the Radio ID number replaces the panel Subscriber ID in panel-generated messages. If you selected N, the radio sends panel-generated messages with the panel Subscriber ID number. This must be programmed with a value, even if it is the same as the primary central station. The alarm panel has the option of sending a selected message to the second central station. Enter Y to review the programming options and to ensure that the correct responses have been made. Parameters can be changed during review. Enter N to end programming session. Panel Linking Module PROMPT 01 PANEL ID# (01-08) EXPLANATION 01 If you selected device type 10 (panel linking module), this prompt appears. Enter the panel’s ID # (01-08). Each panel must have its own unique ID #. This device is supervised as zone “8xx,” where “xx” = the device’s address. If you want to supervise this device, program that zone with response type 05. If you want to supervise panel link modules from other controls, also program them into Zone Programming on a regular zone (001-250) with a response type of 14. Press [✱] to accept entry. – 34 – VIP Module and VISTA Gateway Module PROMPT EXPLANATION 01 MODULE PART. 1 If you selected device type 05 (VIP Module) or type 09 (VGM), this prompt appears. Enter the partition number 1-8 in which the module is located. Press [✱] to accept entry. Press 00 + [✱] to exit Menu mode. Press ✱99 to exit Program mode. Output Programming The system supports up to 96 outputs. Outputs can be used to perform many different functions and actions. Each output must be programmed to begin one of four types of ACTIONS at a designated START event, and end that ACTION at a designated STOP event. The options used to start and stop these devices are described below, followed by the actual screen prompts and available entries. The letter(s) in parentheses after each function described below, such as (A) after ACTION, are those that appear in the various summary displays of programmed data during programming. ACTION (A) START (STT) The "ACTION" of the device is how the device will respond when it is activated by the "START" programming. You may want the device to activate momentarily, to pulse on and off continuously, or to remain activated until some other event occurs to stop it. There are five different action choices: ACTIVATE for 2 SECONDS and then reset. • ACTIVATE and REMAIN ACTIVATED until stopped by some other event. • PULSE ON and OFF until stopped by some other event (do not use with an FSA device). • NO RESPONSE when the device is not used. • TOGGLE on and off alternately with each activation of event. • The "START" programming determines when and under what conditions the device is activated. The following START options are available: 1) EVENT (EV) is the condition (alarm, fault, trouble) that must occur to a zone or group of zones (zone list) in order to activate the device. These conditions apply only when a zone list is used. The different choices for "EVENT" are listed below and in “Programming Relays” later in this section. ALARM Action begins upon any alarm in an assigned zone in the zone list. • FAULT Action begins upon any opening of an assigned zone in the zone list. • TROUBLE Action begins upon any trouble condition in an assigned zone in the zone list. • NOT USED Action is not dependent upon one of the above events. • ZONE LIST (ZL) is a group of zones to which the “EVENT” applies in order to activate a particular device. Note that there are a total of 15 zone lists that can be programmed; when the selected EVENT (alarm, fault or trouble) occurs in any zone in the selected “Start” ZONE LIST (01-15), activation of the selected device will START. 2) ZONE # A specific zone going into alarm, fault, trouble, or restore (Event programming) can be used to start the relay action. Enter the 3-digit zone number (000-250). 3) ZONE TYPE/SYSTEM OPERATION (ZT). If all zones to be used to start the device have the same response type, and there are no other zones of this type that are not to activate this device, then “ZONE TYPE” may be used instead of a "ZONE LIST" and "EVENT” to activate the device. If a system operation, such as “DISARMING” or “ANY FIRE ALARM,” is to activate the device, enter the appropriate choice under the “ZONE TYPE” option. The “ZONE TYPE/SYSTEM OPERATION” option functions independently of the “EVENT/ZONE LIST” combination. If a specific "ZONE TYPE" is chosen, any zone of that response type going into alarm, trouble, or fault will cause the device to activate as selected in "ACTION.” If the same “ZONE TYPE” is also chosen for the STOP programming, any zone of that type that restores will de-activate the device. If a "SYSTEM OPERATION" is chosen, that operation will cause the device to activate as selected in "ACTION.” The different choices for "ZONE TYPE" and "SYSTEM OPERATION" are listed in “Programming Relays” later in this section, and on the Programming Form. 4) PARTITION NO. (P). The device's "Start" ZONE TYPE/SYSTEM OPERATION may be limited to an occurrence on one partition (1-8), or any partition (0). – 35 – STOP (STP): The "STOP" programming determines when and under what conditions the device is de-activated. The following options are available: 1). RESTORE ZONE LIST (ZL). If a "ZONE LIST" is used as the “Stop” event, the device de-activates when all the zones in that list restore from a previous fault, trouble, or alarm condition. This occurs regardless of what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" is normally only used when a "ZONE LIST" is used to start the device. 2). ZONE TYPE/SYSTEM OPERATION (ZT). Instead of using a "RESTORE ZONE LIST," you can select a specific zone (response) type or system operation action to de-activate the device. If you choose a specific "ZONE TYPE," any zone of that response type that restores from a previous alarm, trouble, or fault condition will cause the device to de-activate. If you choose a "SYSTEM OPERATION," that operation causes the device to de-activate. The different choices for "ZONE TYPE" and "SYSTEM OPERATION" are listed in “Programming Relays” later in this section, and in the Programming Form. 3) PARTITION NO. (P). The device's "Stop" Zone Type/System Operation may be limited to an occurrence on one partition (1-8), or on any partition (0). The “ZONE TYPE/SYSTEM OPERATION” option functions independently of the “RESTORE/ZONE LIST” combination. Output Devices Programming From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt. Press [0] (NO) to each menu option until the "OUTPUT PGM?" prompt appears. Press [1] (YES). While in this mode, press [✱] to advance to next screen. Press [#] to back up to the previous screen. PROMPT EXPLANATION ENTER RELAY # (00=QUIT) 01 Enter the relay (output device) identification number 01-96. This is a reference number only, used for identification purposes. The actual module address and relay number on the module are programmed in the last two prompts. Press [✱] to continue. 02 A EV ZL ZT P STT 0 0 00 00 0 Press [✱] to continue. 02 STOP The keypad displays a summary STOP screen. A ZL ZT P 0 00 00 0 02 RELAY ACTION NO RESPONSE 02 START EVENT NOT USED Press [✱] to continue. 0 The Relay Action is the way in which the relay will respond when activated by the "start" event. Enter the desired action for this relay as follows: 0=not used; 1=close for 2 secs.; 2=stay closed; 3=pulse on/off; 4= toggle on and off alternately 0 An output may be activated by an Event/Zone List combination, and/or by a Zone Type/System Operation. For an Event/Zone List combination, enter the event code as follows: 0=not used; 1=alarm; 2=fault; 3=trouble If you are not using a Zone List to activate the relay, enter 0. Press [✱] to continue. 02 START: ZN LIST 00 02 START: ZONE # 000 02 START: ZN TYPE NO RESPONSE 00 A zone list is a set of zones that can be used to initiate the start or stop relay action. If a zone list is being used to start this relay action, enter the zone list number, 1-15. If a zone list is not being used, enter 0. Press [✱] to continue. A specific zone can be used instead of or in addition to an Event/Zone List or Zone Type/System Operation combination to start the relay action. Enter the 3-digit zone number. Press [✱] to continue. A Zone Type/System Operation can be used instead of or in addition to an Event/Zone List combination or a specific zone to start the relay action. If a Zone Type/System Operation is being used, enter the 2-digit code as listed in the table that follows. Press [✱] to continue. – 36 – Choices for Start/Stop Zone Types and System Operations: 00 = No Response (Not Used) 23 = No Alarm Response 01 = Entry/Exit #1 27 = Access Point (allows more than one 02 = Entry/exit #2 relay to be controlled by activation if access point request) 03 = Perimeter 04 = Interior Follower 28 = MLB Supervision 05 = Trouble Day/Alarm Night 29 = Momentary Exit 06 = 24-Hr. Silent 31 = End of Exit Time 07 = 24-Hr. Audible 32 = Start of Entry Time 08 = 24-Hr. Auxiliary 33 = Any Burglary Alarm 09 = Fire Alarm or Trouble 34 = Code + [#] + 71 Key Entry 10 = Interior W/Delay 35 = Code + [#] + 72 Key Entry 14 = PLM Supervision 36 = At Bell Timeout ** 16 = Fire With Verification 37 = 2 Times Bell Timeout ** 20 = Arming-STAY*** 38 = Chime 21 = Arming-AWAY**** 39 = Fire Alarm 22 = Disarming (Code + Off) 40 = Bypassing * Stop condition only ** Or at disarming, whichever occurs earlier *** The output also activates when the partition is armed in the INSTANT mode **** The output also activates when the partition is armed in the MAXIMUM mode 41 = AC Power Fail 42 = System Battery Low 43 = Communication failure 44 = RF Low Battery 45 = Polling Loop Failure 47 = Console Failure 51 = RF Receiver Failure 52 = Kissoff 54 = Fire Zone Reset 55 = Disarm + 1 Minute 56 = XX Minutes (enter XX in field 1*74) * 57 = YY Seconds (enter YY in field 1*75) * 58 = Duress 60 = Audio Alarm Verification (must be selected for both START and STOP operation) If you are using options 56 and/or 57 (usually as the STOP Zone Type), you must program data fields 1*74 and 1*75 for the respective relay timeouts for minutes and seconds. PROMPT EXPLANATION 02 START: ACS PT (00-31) 00 If the start zone type you selected was 27 (access point), this prompt is displayed. Enter the access point (00-31) that will start the relay action. Press [✱] to continue. 02 START: PARTN ANY PARTITION If the starting event will be limited to occurring on a specific partition, enter the partition number (1-8) in which the start event will occur. Enter 0 for any partition. Press [✱] to continue. 0 Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not deactivate the relay. PROMPT EXPLANATION 02 STOP: ZN LIST If a zone list is being used to stop this relay action, enter the zone list number, 1-15. The restore of a zone on the zone list stops the relay. If a zone list is not being used, enter 0. Press [✱] to continue. 00 02 STOP: ZN TYPE NO RESPONSE 00 If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the Choices for Start/Stop System Operation chart. Press [✱] to continue. 02 STOP: ACS PT (00-31) 00 If the stop zone type you selected was 27 (access point), this prompt is displayed. Enter the access point (00-31) which will stop the relay action. 02 STOP: PARTN ANY PARTITION This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-8 for specific partition number. Press [✱] to continue. 0 Press [✱] to continue. – 37 – PROMPT EXPLANATION 02 RELAY GROUP Relays may be grouped for common activation by time-driven events (commands 06-10). Enter 00 (no group) or 01-15 for a specific group number. 00 02 RESTRICTION 1=YES 0=NO 0 02 RELAY TYPE V-PLEX 0 Press [✱] to continue. The system may have some devices that are not intended to be under end user control, such as relays activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay group. Press [✱] to continue. Enter 0 for V-Plex (polling loop) devices. Enter 1 for (ECP) relay modules (4204/4204CF). Enter 2 for (X10) Powerline Carrier devices. Enter 3 for (FSA) Fire System Annunciator. Press [✱] to continue. 02 V-PLEX ZONE # 000 For polling loop trigger outputs (4101SN), enter the protection zone number (001-250) linked to each output, if used. Be sure to enroll the module’s serial number (see Zone Programming). 02 ECP ADDRESS If you selected 1 or 3 for (4204/4204CF or FSA), enter the actual module's address (01-15 – 4204/4204CF) (08-23 – FSA) as set by its DIP switches. Up to 8 4204/4204CF modules and up to 4 FSA modules can be installed in a system. 00 Press [✱] to continue. Press [✱] to continue. 02 MODULE RELAY# 0 02 HOUSE CODE A 00 For 4204 Relay Outputs, enter the specific relay number on that module (1-4). For 4204CF outputs, enter only module relay number 1 (Output A) or relay number 3 (Output B). These are the only two programmable relays on the 4204CF Module. Press [✱] to continue. The keypad will display the Start and Stop summary screens again. Press [✱] to continue. If you selected 2 for Powerline Carrier devices, enter the numerical equivalent of the House Code of the device, as follows: A=00 D=03 G=06 J=09 M=12 P=15 B=01 E=04 H=07 K=10 N=13 C=02 F=05 I=08 L=11 O=14 Enter the numerical unit code of the Powerline Carrier device (00-15). 02 UNIT CODE 00 Press [✱] to continue. The keypad displays the Start and Stop summary screens again. Press [✱] to continue. Enter the LED number on the FSA module (01-08 for FSA-8; 01-24 for FSA-24). 01 LED # 00 Press [✱] to continue. The keypad displays the Start and Stop summary screens again. Press [✱] to continue. When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt. If you are defining a zone list, continue to the next section. If not, enter 00 + [✱] at the next two prompts. You will then be asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter ✱99 to exit programming completely. If supervision of the 4204CF Relay Output is desired, enter a response type for that output's corresponding supervisory zone. This is equal to 600 + [Relay ID No.]. For example, if you are programming Relay ID No. 1, the relay's supervisory zone 601. Program this zone with response type 05 (Day/Night) in Zone Programming. Zone List Programming After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows: PROMPT EXPLANATION ENTER Zn LIST ? 00=QUIT Enter the zone list number 01-15. Enter 00 to quit. 00 – 38 – PROMPT EXPLANATION 01 ADD ZONE # 000=QUIT Using 3-digit entries, enter each zone to be included in this zone list. Press [✱] after you enter each zone number. When you have entered all zones, enter 000. 000 Press [✱] to continue. Enter 0 to save this zone list. Enter 1 to delete it. 01 Del Zn LIST ? 1=YES 0=NO 0 01 DEL ZONES ? 1=YES 0=NO 0 Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If you enter 1, the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears. 01 Zn to DELETE ? 000=QUIT 000 Enter each zone number to be deleted from the zone list, pressing [✱] after each number. VIEW Zn LIST ? 00=QUIT This display appears if you pressed 00 at the “Enter Zone LIST” prompt. Enter the zone list number that you wish to view. 00 01 ASSIGNED ZONE 000=QUIT 000 Press [✱] to continue. Press [✱] to scroll through all zones in that list. Enter 000 +[✱] to quit. Press [1] to exit Menu Mode. Press ✱99 to exit Program Mode. Relay Voice Descriptors If you are using the 4285/4286 VIP Module, voice descriptors can be programmed for outputs 1-32 (even though the system has 96 outputs, only 1-32 can have a Relay Voice Descriptor programmed). These descriptors are announced by the voice module when you access the relays via the # 70 Relay Access Mode over the telephone. Each voice descriptor can consist of up to 3 words selected from the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list (later in this section). The index numbers from this vocabulary list are to be used for relay voice descriptors only. For normal system voice annunciation (e.g., alarms, troubles, status), use the highlighted words in the alpha vocabulary list in the Alpha Programming part of this guide. To enter relay voice descriptors, do the following: 1. From Data Field Programming mode, press #93 to display the "ZONE PROG?" prompt. 2. Press [0] (NO) to each menu option until the "RLY VOICE DESCR?" prompt is displayed. Follow the instructions below. While in this mode, press [✱] to advance to next screen. Press [#] to back up to previous screen. PROMPT RLY VOICE DESCR? 1=YES 0=NO EXPLANATION Press [1] to program voice descriptors for relays. 0 PROMPT EXPLANATION ENTER RELAY NO. 00=QUIT 01 Enter the 2-digit relay number (01-32) for the relay desired, or enter 00 to quit Relay Voice Descriptor Programming Mode. 01 ENTER DESC d1 From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index number for the first word of the relay descriptor phrase. Press [✱] Press [✱] to accept entry. – 39 – PROMPT EXPLANATION 01 ENTER DESC d2 From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index number for the second word of the relay descriptor phrase. If second word is not desired, press [000]. Press [✱] to accept entry. From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index number for the third word of the relay descriptor phrase. If third word is not desired, press [000]. 01 ENTER DESC d3 Press [✱] to accept entry. The “ENTER RELAY NO.” prompt appears. Enter the next relay number to be programmed. When you have programmed all output devices, enter 00 to quit. Enter ✱99 to exit Program Mode. Relay Voice Descriptors and Custom Word Substitutes Vocabulary Words italicized indicate those words supported by the 6160V Voice keypad. Word Index Air ............................ 116 Alarm ....................... 255 And .......................... 067 Apartment ................ 117 Appliances ............... 161 Area ......................... 118 Attic.......................... 119 Word Index Daughter's ................208 Den...........................052 Detector....................128 Device ......................060 Dim ...........................163 Dining .......................031 Door..........................016 Down ........................008 Downstairs................184 Driveway...................130 Duct ..........................131 Baby......................... 120 Back......................... 121 Bar ........................... 122 Basement................. 021 Bathroom ................. 051 Battery ..................... 053 Bed .......................... 092 Bedroom .................. 015 Blower...................... 123 Boiler........................ 124 Bright ....................... 162 Building .................... 125 Burglary ................... 039 Word Index Front......................... 087 Garage ..................... 023 Gas .......................... 138 Glass........................ 139 Hall........................... 050 Heat ......................... 010 Inside ....................... 209 Kitchen ..................... 022 East ..........................132 Eight .........................077 Eighth .......................221 Equipment ................133 Exit ...........................004 Factory .....................134 Father's.....................211 Fence .......................135 Fifth ..........................218 Fire ...........................040 First .........................136 Five...........................074 Floor .........................029 Four ..........................073 Fourth .......................217 Foyer ........................137 Call .......................... 009 Central ..................... 089 Chime ...................... 054 Closed...................... 126 Computer ................. 127 Console.................... 066 Laundry .................... 140 Left ........................... 027 Library ...................... 141 Light ......................... 019 Living........................ 030 Loading .................... 142 Lower ....................... 094 Machine.................... 143 Master ...................... 144 Medical..................... 014 Mother's ................... 212 Motion ...................... 145 Nine.......................... 078 Ninth......................... 222 Word Index No ............................ 165 North........................ 146 Not ........................... 012 Off............................ 011 Office ....................... 147 On............................ 058 One.......................... 070 Open........................ 148 Outside .................... 210 Panic........................ 013 Partition.................... 090 Patio ........................ 149 Phone ...................... 061 Power ...................... 063 Pump ....................... 166 Rear ........................ 088 Right ........................ 028 Room ....................... 018 's .............................. 007 Second..................... 056 Service..................... 150 Seven ...................... 076 Seventh.................... 220 Shed ........................ 151 Shop ........................ 152 Word Index Side ......................... 153 Six ........................... 075 Sixth ........................ 219 Smoke ..................... 024 Son's ....................... 223 South....................... 155 Stairs ....................... 006 Station ..................... 156 Storage.................... 157 Sun.......................... 154 System .................... 062 Temperature ............ 158 Third ........................ 159 Three....................... 072 Tool ......................... 213 Two ......................... 071 Up............................ 025 Upper ...................... 187 Upstairs ................... 183 Utility ....................... 185 West ........................ 215 Window.................... 017 Wing ........................ 216 Zero......................... 069 Zone ........................ 002 Custom Word Substitutes for VIP Module Annunciation A substitute word can be programmed for each of the 60 custom words used in your alpha zone descriptions. The VIP Module announces this substitute word in place of the custom word that is displayed on the alpha keypad. For example, an alarm display of "John's Bedroom" could be announced as "Son's Bedroom," as there is no annunciation for the custom word "John." Note that if a substitute word is not assigned, the VIP Module will not annunciate the zone descriptor at all, but will only annunciate the zone number. To enter custom word substitutes, do the following: 1. From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt. 2. Press [0] (NO) to each menu option until the "CUSTOM INDEX ?" prompt is displayed. PROMPT CUSTOM INDEX ? 1=YES 0=NO CUSTOM WORD NO. 00=QUIT EXPLANATION Enter [1] at this prompt. 0 Enter the custom word number (01-60) for which a voice substitute is desired. Enter 00 to quit this Programming Mode. Press [✱] to accept entry. – 40 – PROMPT EXPLANATION Enter the 3-digit substitute word index number from the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list in the Relay Voice Descriptors part of this section. 01 ENTER INDEX # Press [✱] to accept entry. The "CUSTOM WORD NO." prompt is displayed. Enter the next custom word number to be substituted, or enter 00 to quit. Scheduled Check-in The system can be programmed to call the downloader automatically, at a scheduled time. Once the connection is made, the downloader can perform any and all functions (arm, disarm, upload, etc.). The downloader determines the functions it performs. To enter scheduled check-in, do the following: 1. From Data Field Programming mode, press #93 to display the "ZONE PROG?" prompt. 2. Press [0] (NO) to each menu option until the "SCHEDULED CHK-IN" prompt is displayed. PROMPT EXPLANATION SCHEDULED CHK-IN 1=YES 0=NO Enter [1] at this prompt. 0 Chk-In Interval None 0 Enter the check-in interval. 0 = None; 1 = Weekly; 2 = Monthly; 3 = Quarterly; 4 = Yearly. Press [✱] to accept entry. DAY: M T W T F S S 1 2 3 4 5 6 7 1 If you selected 1 (weekly), the Day of the Week prompt is displayed. Enter the day of the week (1-7). Quarter of Year JAN, APR, JUL, OCT If you selected 3 (quarterly), the Quarter of the Year prompt is displayed. Enter the quarter of the year. 0 = January, April, July, and October; 1 = February, May, August, and November; 2 = March, June, September, and December. 0 Press [✱] to accept entry and move to the Time of the Day prompt. Press [✱] to accept entry and move to the Day of the Month prompt. Month of Year (01-12) Day of Month (01-28) If you selected 4 (yearly), the Month of Year prompt is displayed. Enter the month (01-12). 01 Press [✱] to accept entry and move to the Day of the Month prompt. 01 Press [✱] to accept entry and move to the Time of the Day prompt. If you selected 2 (monthly), the Day of the Month prompt. Enter the day of the month (01-28). The Time of the Day prompt is displayed. Enter the time of day for the check-in. Enter the hour of the day (01-12). Press [✱] to accept entry. The cursor moves to the minutes position. (Press the [#] to move the cursor backwards.) Enter the minutes of the hour (00-59). Press [✱] to accept entry. Time of Day 12:00AM The cursor moves to the AM/PM position. Press [✱] to accept the current selection or press any key (1-9) except the [✱] or [#] to toggle the AM/PM selection. NOTE: The programming of field 1*71 determines the time of day format (12- or 24-hour). QUIT MENU MODE? 1 = YES 0 = NO Enter 1 to exit back to normal programming mode. Enter 0 to stay in menu mode. 0 – 41 – System Layout Worksheets Before programming any security system, you should first define the installation. To help you lay out a partitioned system, use the following worksheets. This will further simplify the programming process. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See page 2 of this manual for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Partition # Descriptor (4-char max) Prim. Sub. # PARTITIONS Sec. Sub. # Alpha Default Message (32-character maximum) Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 Keyswitch Arming Partition Assignment (1-8): Wireless Keypad Partition Assignment (1-8): Voice Module Partition Assignment (1-8): Use Partition Descriptor (yes/no)? Common Lobby Partition Assignment (1-8): COMMUNICATION OPTIONS BY PARTITION Part. 1 Part. 2 Part. 3 Part. 4 Option Part. 5 Part. 6 Part. 7 Part. 8 SYSTEM DEFINITIONS BY PARTITION (enter values or yes/no) Part. 1 Part. 2 Part. 3 Part. 4 Part. 5 Part. 6 Part. 7 Part. 8 Swinger Suppression Count 00-15; 00=no suppression Cancel Report After Disarm Dialer Reports for Panic (* + 1) Dialer Reports for Panic (# + 3) Dialer Reports for Panic (* + #) Dialer Reports for Duress Burglary Alarm Communications Delay (16 sec.) Option Entry Delay #1 (00, 30-225 seconds): Exit Delay #1 (00, 45-225 seconds): Entry Delay #2 (00, 30-225 seconds): Exit Delay #2 (00, 45-225 seconds): Quick Arming Multiple Alarms per Arming Console Panic for Zone 995 (* + 1) Console Panic for Zone 996 (# + 3) Console Panic for Zone 999 (* + #) Allow Sign-on (GOTO function) Non-Bypassable Zone* Sounder Timeout Duration for Bell (2 min. increments) Console Annunciation During Entry** Console Annunciation During Exit Confirmation of Arming Ding for Bell Chime on Bell Access Control Relay (field 1*76) Affects Lobby (check partitions that apply) Arms Lobby (check partitions that apply) Displays Fire Alarms of Other Partitions Displays Burg & Panic Alarms of Other Partitions Displays Troubles of Other Partitions *Can be any zone 001-250. **no= 3 beeps yes=continuous – 42 – PRINTER OPTIONS Parallel or Serial printer 12- or 24-hour Time format Printer On-Line (yes/no) *1200 or 300 baud Printer Baud Rate *Note: Must be 1200 if using pager interface Addr Type Part 00. 01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. EVENT LOG TYPES No Option Alarm Trouble Bypass Open/Close System Yes DEVICES (keypads, 4204, rf receivers, vip module, lrr, vgm, TeleSmart plm) Sound Supv House Kypd Panel AUI Opt CF? ID Glbal ID Device Types: 00 = Device Not Used 01 = Alpha Console 03 = RF Receiver 04 = Output Relay Module 05 = Voice Module 06 = Long Range Radio 08 = Fire Display Module 09 = Vista Gateway Module 10 = Panel Link Module 11 = TeleSmart NOTES: Address 04 must be used for the Voice Module, if used. Address 24 must be used for TeleSmart, if used. If using TeleSmart, program address 23 as an alpha console, but do not connect a console with that address. Console Sounder Options: 0 = No Suppression 1 = Suppress Arm/Disarm and Entry/Exit Beeps 2 = Suppress Chime Mode Beeps Only 3 = Suppress Arm/Disarm, Entry/Exit and Chime Mode Beeps Defaults: Addresses 00 = Addresses 01 = Alpha Keypad; No Suppression AUI, Keypad Global disabled ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 1 & 2 4-digit Security Code Access Group 0; 1-8 3-Digit User # Auth. Level Partition 1 Open/ Group Close Bypass RF Key – 43 – Global Arm 3-Digit User # Auth. Level Partition 2 Open/ Group Close Bypass RF Key Global Arm ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 3 & 4 4-digit Security Code Access Group 0; 1-8 4-digit Security Code Access Group 0; 1-8 4-digit Security Code Access Group 0; 1-8 3-Digit User # Auth. Level Partition 3 Group Open/ Bypass Close RF Key Global Arm 3-Digit User # Auth. Level Partition 4 Group Open/ Bypass Close RF Key Global Arm RF Key Global Arm RF Key Global Arm ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 5 & 6 3-Digit User # Auth. Level Partition 5 Group Open/ Bypass Close RF Key Global Arm 3-Digit User # Auth. Level Partition 6 Group Open/ Bypass Close ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 7 & 8 3-Digit User # Auth. Level Partition 7 Open/ Group Close Bypass RF Key Global Arm 3-Digit User # Authority Levels: 1=Master (arm, disarm, bypass, and/or modify lower level users) 2=Manager (arm, disarm, bypass, and/or modify lower level users) 3=Operator A (arm, disarm, bypass) 4=Operator B (arm, disarm) 5=Operator C (arm, disarm only if system was armed with this code) 6=Duress code (arm, disarm, triggers silent panic alarm) – 44 – Auth. Level Partition 8 Open/ Group Close Bypass Defaults: User 4-Digits User 1 (Installer) 4140 User 2 1234 Alpha INSTLR MASTER — 45 — 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # ZONE DEFINITION FOR ZONES 001-025 Tamper Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 46 — 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # ZONE DEFINITION FOR ZONES 026-050 Tamper Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 47 — 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 051-075 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 48 — 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 076-100 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 49 — 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 101-125 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 50 — 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 126-150 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 51 — 175 174 173 172 171 170 169 168 167 166 165 164 163 162 161 160 159 158 157 156 155 154 153 152 151 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 151-175 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 52 — 200 199 198 197 196 195 194 193 192 191 190 189 188 187 186 185 184 183 182 181 180 179 178 177 176 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 176-200 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 53 — 225 224 223 222 221 220 219 218 217 216 215 214 213 212 211 210 209 208 207 206 205 204 203 202 201 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 201-225 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words — 54 — 250 249 248 247 246 245 244 243 242 241 240 239 238 237 236 235 234 233 232 231 230 229 228 227 226 Zone No. Zone Type Part 1-8 Input Type Arm w/Fault Vent Zone STAY Mode AutoSTAY Silent Bypass Group Access Point Panel ID # Tamper ZONE DEFINITION FOR ZONES 226-250 Serial # / Loop Rpt. Code Zone Information (part numbers) & Alpha Descriptor (3 words ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 995, 996, & 999 Enter yes/no for each partition-field *22 Zone No. Zone Type 1 2 3 4 5 6 7 8 Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) 995 996 999 ZONE DEFINITIONS FOR SYSTEM ZONES; 970, 988; 990 & 997 Zone No. Zone Type Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) 970 988 990 997 — 55 — ZONE DEFINITIONS FOR RELAY SUPERVISORY ZONES 601-632 Zone No. Zone Type Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) Zone No. 601 617 602 618 603 619 604 620 605 621 606 622 607 623 608 624 609 625 610 626 611 627 612 628 613 629 614 630 615 631 616 632 — 56 — Zone Type Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) ZONE DEFINITIONS FOR SUPERVISORY OF ECP DEVICE ZONES 800-830 Zone No. Zone Type Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) Zone No. 800 816 801 817 802 818 803 819 804 820 805 821 806 822 807 823 808 824 809 825 810 826 811 827 812 828 813 829 814 830 Zone Type Report Code Zone Information (part numbers) & Alpha Descriptor (3 words max.) 815 Zone Types: 00=zone not used 01=entry/exit 1 02=entry/exit 2 03=perimeter 04=interior (follower) 05=day/night burglary 06=24-hour silent 07=24-hour audible 08=24-hour auxiliary 09=supervised fire 10=interior (delay) 14=panel link supervision 16=fire w/verification 20=arm stay 21=arm away 22=disarm 23=no alarm response 27=access control 28=MLB supervision 29=momentary exit Input Types: 00=not used 01=hardwired 02=RF motion transmitter 03=supervised RF transmitter 04=unsupervised RF transmitter 05=RF button transmitter 06=serial number polling loop 07=Dip switch-type polling loop 08=right loop dip switch polling loop 09=keypad input 10=PassPoint ACS input 11=VistaKey door status monitor 12=VistaKey request to exit 13=VistaKey general purpose — 57 — Output Devices Worksheets Applicable only if relays (4204/4204CF), FSA Modules, V-Plex or Powerline Carrier Devices (X-10) are used. Output Devices – Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For 4204/4204CF and FSA, the Device Programming section must be programmed for the device address. Set the DIP switches on the device for that address. 2. For V-Plex, devices must be programmed in the Zone Programming section. 3. For Powerline Carrier Devices (X-10), use the 4300 transformer in place of the transformer that comes in the box with the control panel. S T A R T OUTPUT DEV # A EV/ZL Zone S T O P ZT / P ZL ZT / P 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. — 58 — Relay Group Restrict 0=V-Plex 1=4204 2=X-10 3=FSA V-Plex Zone # or Dev Add 4204 or FSA or House Code for X-10 Relay # for 4204 or LED # for FSA or Unit Code for X-10 OUTPUT DEVICES WORKSHEET (cont’d) S T A R T OUTPUT DEV # A EV/ZL Zone S T O P ZT / P ZL ZT / P 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. — 59 — Relay Group Restrict 0=V-Plex 1=4204 2=X-10 3=FSA V-Plex Zone # or Dev Add 4204 or FSA or House Code for X-10 Relay # for 4204 or LED # for FSA or Unit Code for X-10 OUTPUT DEVICES WORKSHEET (cont’d) S T A R T OUTPUT DEV # A EV/ZL Zone S T O P ZT / P ZL ZT / P 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. — 60 — Relay Group Restrict 0=V-Plex 1=4204 2=X-10 3=FSA V-Plex Zone # or Dev Add 4204 or FSA or House Code for X-10 Relay # for 4204 or LED # for FSA or Unit Code for X-10 OUTPUT DEVICES WORKSHEET (cont’d) S T A R T OUTPUT DEV # A EV/ZL Zone S T O P ZT / P ZL ZT / P 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. — 61 — Relay Group Restrict 0=V-Plex 1=4204 2=X-10 3=FSA V-Plex Zone # or Dev Add 4204 or FSA or House Code for X-10 Relay # for 4204 or LED # for FSA or Unit Code for X-10 A = DEVICE ACTION EV = ZL = ZT = 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off; 4 = Toggle alternately between START and STOP events EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore ZONE LIST 01-15, 00 = Not Used "START" ZONE LIST: Upon alarm, fault, trouble or restore of ANY zone in this list, device action will START. "STOP" ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It need not be same list as used for START. ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are: 00=zone not used 01=entry/exit 1 02=entry/exit 2 03=perimeter 04=interior (follower) 05=day/night burglary 06=24 hour silent NOTE: 07=24-hour audible 08=24-hour auxiliary 09=supervised fire 10=interior (delay) 14=PLM supervision 16=fire w/verification 20=arm stay 21=arm away 22=disarm 23=no alarm response 26=VGM supervision 27=access control 28=MLB supervision 29=momentary exit Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay. Any zone in "ZT" for Stop, that restores will stop the relay action. Choices for System Operation are: 00 = No Response (Not Used) 01 = Entry/Exit #1 02 = Entry/exit #2 03 = Perimeter 04 = Interior Follower 05 = Trouble Day/Alarm Night 06 = 24-Hr. Silent 07 = 24-Hr. Audible 08 = 24-Hr. Auxiliary 09 = Fire Alarm or Trouble 10 = Interior W/Delay 16 = Fire With Verification 20 = Arming-STAY*** 21 = Arming-AWAY**** 22 = Disarming (Code + Off) 23 = No Alarm Response * ** *** **** P= 27 = Access Point (allows more than one relay to be controlled by activation if access point request) 28 = MLB Supervision 29 = Momentary Exit 31 = End of Exit Time 32 = Start of Entry Time 33 = Any Burglary Alarm 34 = Code + [#] + 71 Key Entry 35 = Code + [#] + 72 Key Entry 36 = At Bell Timeout ** 37 = 2 Times Bell Timeout ** 38 = Chime 39 = Fire Alarm 40 = Bypassing 41 = AC Power Fail 42 = System Battery Low 43 = Communication failure 44 = RF Low Battery 45 = Polling Loop Failure 47 = Console Failure 51 = RF Receiver Failure 52 = Kissoff 54 = Fire Zone Reset 55 = Disarm + 1 Minute 56 = XX Minutes (enter XX in field 1*74) * 57 = YY Seconds (enter YY in field 1*75) * 58 = Duress 60 = Audio Alarm Verification (must be selected for both START and STOP operation) Stop condition only Or at Disarming, whichever occurs earlier The output also activates when the partition is armed in the INSTANT mode The output also activates when the partition is armed in the MAXIMUM mode PARTITION No. 1-8, 0 = Any ZONE LISTS FOR OUTPUT DEVICES – Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter the data during the displays and prompts that appear in sequence. Up to 15 zone lists may be created Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include any or all of system's zone numbers. Zone List 1: Started or stopped by zone numbers (enter 000 to end entries). Zone List 2: Started or stopped by zone numbers (enter 000 to end entries). — 62 — Zone List 3: Started or stopped by zone numbers (enter 000 to end entries). Zone List 4: Started or stopped by zone numbers (enter 000 to end entries). Zone List 5: Started or stopped by zone numbers (enter 000 to end entries). Zone List 6: Started or stopped by zone numbers (enter 000 to end entries). Zone List 7: Started or stopped by zone numbers (enter 000 to end entries). Zone List 8: Started or stopped by zone numbers (enter 000 to end entries). Zone List 9: Started or stopped by zone numbers (enter 000 to end entries). Zone List 10: Started or stopped by zone numbers (enter 000 to end entries). Zone List 11: Started or stopped by zone numbers (enter 000 to end entries). Zone List 12: Started or stopped by zone numbers (enter 000 to end entries). Zone List 13: Started or stopped by zone numbers (enter 000 to end entries). — 63 — Zone List 14: Started or stopped by zone numbers (enter 000 to end entries). Zone List 15: Started or stopped by zone numbers (enter 000 to end entries). Scheduling Menu Prompts To program schedules, enter Scheduling program mode by pressing [User Code] + # + 80 to display the first choice of the menu driven programming functions. NOTE: Only users with an Installer or Master level user code may enter the #80 mode. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows: PROMPT EXPLANATION Time Window ? 1 = YES 0 = NO For defining up to 20 time windows each with a start and a stop time programmed by entering the hours and minutes. 0 O/C Schedules ? 1 = YES 0 = NO 0 Holidays ? 1 = YES 0 = NO 0 Timed Events ? 1 = YES 0 = NO Access Sched. ? 1 = YES 0 = NO For defining the daily open and close schedules for the 8 partitions. Each partition can be programmed with an opening and closing window for each day of the week and holidays. For defining up to 16 holidays for which partitions they apply. 0 0 For defining up to 20 time driven events with the following parameters: Time window • Action desired • Action specifier • Activation time • Days of the week • For defining the limitation of access schedules for the user codes. Each schedule can be programmed with two window for each day of the week and holidays #80 & #81 MENU MODE KEY COMMANDS The following is a list of commands used while in the Menu mode. #80 or #81 [✱] Enters Menu mode Serves as ENTER key. Press to have keypad accept entry. [#] Backs up to previous screen. 0 Press to answer NO. 1 Press to answer YES. 01-09 00 All data entries are either 2-digit entries. Exits Menu mode, returns to normal operation mode when entered at the first question for each category. — 64 — Scheduling Worksheets Time Windows Definitions Worksheet. The system provides 20 time windows that are defined with start and stop times. They are programmed in the #80 Menu Mode. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Time Window Start Time Stop Time Number (HH:MM) (HH:MM) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 (Keep this worksheet handy, as you will be asked for a given time window number later in this section). Because the time windows are shared among all partitions, it is important to make sure that changing a time window does not adversely affect desired actions in other partitions. Daily Open/Close Schedule Worksheet: Using the time windows previously defined, fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Part Mon Op Cl Tues Op Cl Wed Op Cl Thur Op Cl 1 2 3 4 5 6 7 8 — 65 — Fri Op Cl Sat Op Cl Sun Op Cl Hol Op Cl Holiday Schedule Worksheet: The system provides up to 16 holidays that can be assigned for the system. Each holiday can be assigned to any combination of partitions. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. HOL Partition Month/Day 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14 / 15 / 16 / 1 2 3 4 5 6 7 8 Time-Driven Event Worksheet: The system provides up to 20 time-driven events that can be programmed for the system. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Sched Num. 1 Time Window Day(s) M T W T F S S H Action Desired 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 — 66 — Action Specifier Activation Time Automatic Refresh: The system automatically updates the status of all Time-Driven Events upon any of the following occurrences: Changing of the time or date via #63 mode • Exiting #80 Scheduling Menu mode • Exiting Program mode • After a disconnect from the downloader • On a power-up • At Daylight Saving Time adjustment. • Below is a list of the "Action" codes (desired actions) used when programming time-driven events. Note that these codes are independent of the "relay codes" programmed during the #93 Menu Mode–Output Programming mode. If using Time Driven Events, the following menu items must first be programmed using #93 Menu Mode - Output Programming: Enter Relay No. (reference identification number) ECP Address (4204/4204CF or FSA) Relay Group (if applicable) Relay No. (4204/4204CF) Restriction LED No. (FSA) Relay Type (V-Plex, 4204/4204CF, FSA, or X-10) House Code (X-10) Zone No. (V-Plex) Unit Code (X-10) Relay commands: Action Specifier for commands 01-05 is Relay No.; Action Specifier for commands 06-10 is Relay Group No. 01 = Relay On 02 = Relay Off 03 = Relay Close for 2 seconds 04 = Relay Close XX minutes (field 1*74) 05 = Relay Close YY seconds (field 1*75) 06 = Relay Group On 07 = Relay Group Off 08 = Relay Group Close for 2 seconds 09 = Relay Group Close XX minutes (field 1*74) 10 = Relay Group Close YY seconds (field 1*75) Arm/Disarm commands: Action Specifier for commands 20-24 is Partition(s). Activation times 1 (Beginning), 2 (End), 3 (During), 5 (Random Start), 6 (Random End), 7 (Random During) are the only valid choices for auto-arming and disarming functions. 20 = Arm-Stay 21 = Arm Away 22 = Disarm 23 = Force Arm Stay (Auto-bypass faulted zns) 24 = Force Arm Away (Auto-bypass faulted zns) 25 = Arm Instant 26 = Arm Maximum Bypass commands: Action Specifier for commands 30-31 is Zone List #, Activation times 1 (Beginning), 2 (End), 3 (During), 5 (Random Start), 6 (Random End), 7 (Random During) are the only valid choices for bypass commands. 30 = Auto bypass - Zone list 31 = Auto unbypass - Zone list Open/Close Windows: Action Specifier for commands 40-41 is Partition(s), and for 42 is Access Group. Activation time 3 (During), 7 (Random During) are the only valid choices for these commands. 40 = Enable Opening Window 41 = Enable Closing Window 42 = Enable Access Window Access Control Commands Action Specifier for commands 55-60 is Access Point, for 61-66 is Group, for 67-72 is Partition, and for 73-74 is Trigger. 55 = Access Point Grant 56 = Access Point Grant with Override 57 = Access Point Protect 58 = Access Point Bypass 59 = Access Point Lock 60 = Access Point Exit 61 = Access Point Group Grant 62 = Access Point Group Grant with Override 63 = Access Point Group Protect 64 = Access Point Group Bypass 65 = Access Point Group Lock 66 = Access Point Group Exit 67 = Access Point Partition Grant 68 = Access Point Partition Grant with Override 69 = Access Point Protect by Partition 70 = Access Point Bypass by Partition 71 = Access Point Lock by Partition 72 = Access Point Exit by Partition 73 = Access Point Trigger On 74 = Access Point Trigger Off Additional Commands Action Specifier for command 78 is Group. 78 = Access Point Group Disable — 67 — Activation time: Refers to when the action is to take place relative to the time window. 1 = Beginning of time window 4 = Beginning and end of time window 2 = End of time window 5 = Random Start of the time window ✳ 3 = During time window active period only (On at 6 = Random End of the time window ✳ beginning of window, off at end). 7 = Random During the time window ✳ ✳ The activation time of the window is randomized up to 30 minutes and is initialized by either of two methods: a. [User Code] + [#] + [41] − Initiates the random schedule for all devices in the partition. b. [User Code] + [#] + [42] − Initiates the random schedule for all devices in the partition with a time window within 6 PM and 5 AM. Limitation of Access Worksheet The system provides up to 8 Access Schedules that can be programmed for the system. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Acc Sch Mon W1 Tues W2 W1 W2 Wed W1 W2 Thurs W1 Fri W2 W1 Sat W2 W1 Sun W2 W1 W2 Hol W1 W2 1 2 3 4 5 6 7 8 Temporary Schedule #81 Menu Mode. The system provides a Temporary Schedule for each partition. Enter the temporary scheduling mode by pressing [Installer Code] + [#] + [81]. Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence. Partition/Windows 1 Mon Tue Wed Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 2 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM — 68 — Thu Fri Sat Sun Partition/Windows 3 Mon Tue Wed Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 4 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 5 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 6 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 7 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window 8 Start Time HH:MM Stop Time HH:MM Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM — 69 — Thu Fri Sat Sun WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. 6 7 8 9 10 TRANSFORMER 16.5VAC, 40VA ADEMCO No.1361 (IN CANADA USE No. 1361CN) or 4300 IF X-10 DEVICES WILL BE USED NOTE: WHEN POWERING UP THE PANEL, PLUG THE TRANSFORMER IN BEFORE CONNECTING THE BATTERY. ASSEMBLED IN MEXICO 13 ZONE 4 ZONE 5 14 15 16 ZONE 6 ZONE 7 17 18 19 21 22 23 - Red Blk Grn Yel REMOTE KEYPAD Use 6137/6128 or 6139 (Addressable keypads) only See Installation Instructions for max # of keypads and for max wire run length. BELL + - SIREN + + - AUXILARY POWER OUTPUT 9.6VDC - 13.8VDC, 750mA maximum Note: Include current drawn by keypads and polling loop devices when making auxiliary power calculations. 24 + + N.C. - - + + - N.C. N.C. + N.C. N.O. N.O. N.O. N.O. 2k EOLR (note 1) 2k EOLR (note 1) 2k EOLR (note 1) 2k EOLR (note 1,3) + Fire Usage N.C. SMOKE - + + N.C. N.O. N.C. - 2k EOLR 2k EOLR (note 1) (note 1) N.O. ALARM SOUNDER OUTPUT 10VDC - 13.8VDC Notes For UL Household Zone resistance (Excluding EOLR): Fire Installations ZONE 1,8: 100 OHMS MAXIMUM 2k EOLR 1. Use 12VDC, 14AH battery ALL OTHER ZONES: 300 OHMS MAXIMUM (note 1,2) 2. Maximum auxiliary current, Zone response time: including polling loop 300mA ZONES 1: 350mSec-500mSec 3. Combined alarm and auxilary power output and polling loop current must be limited to 750mA for UL985 Household Fire Installations. ALL CIRCUITS ARE POWER LIMITED. VISTA-128BP SUMMARY OF CONNECTIONS N.O. 2k EOLR (note 1,4) Handset 28 27 29 Incoming Phone Line Telephone connections using Ademco No. 620 RJ31X direct connect cord. 4208U RPM N.C. 4192SD SMOKE N.C. 4191SN PIR N.O. Burg. Usage - 26 + GLASS BREAK N.C. 25 POLLING LOOP + MAKE CONNECTIONS USING No. 4142TR CABLE J8 1 2 3 4 5 6 7 8 9 J7 1 2 3 4 5 6 7 8 9 ZONE 8 ZONE 9 20 LATCHING TYPE GLASS BREAK DETECTOR LOOP Connect to 24hr. 120VAC, 60 Hz Outlet 2-WIRE SMOKE DETECTOR LOOP (Also supports NO/NC Burg contacts) — 70 — Replace every 3 years 12 ZONE 1 Data out See Installation and Set up Guide for required capacity 11 ) 5 RI (R NG ED ) 4 (G TIP RE EN 3 J7 Header J8 Header 1. Not Used 1. I n 2 (Printer DTR) Optional programming: Out 1: Smoke Detector Reset 2. Ground 2. GroundOut 2: Armed LED 3. Out 1 (Ground Start) 3. In 3 (4300 sync) Out 4: Ready LED 4. In 4 (4300 sync) 4. GroundRatings for Out 1: 5. Ground 5. Out 2 (fire) Active: 10VDC-13.8VDC through 4k OHMS 6. Out 5 (4300 data) 6. Ground7. Out 3 (burg/aud. panic) 7. Out 6 (Printer RXD) Not Active: 100 OHMS to ground Ratings for out 2-4: 8. Ground 8. Ground Active: 10VDC-13.8VDC through 5k OHMS 9. Ground 9. Out 4 (silent panic/ Not Active: 1k OHMS to ground duress) (Refer to Installation and Setup Guide for information concerning Direct Wire Downloading and printer connections.) ) R (G ING RA Y) 2 Data in CHARGING VOLTAGE 13.7VDC ZONE 2 ZONE 3 1 NO CONNECTION GEL CELL BATTERY RED (+) Connect to 12VDC, 4AH or 12VDC, 7AH BLK (-) Blue Jumper (note 5) 4. Zone 8 supports 2-wire latching type glass break detectors. 1. Zone 1 may be selected for EOLR supervised See Installation and Setup Guide for recommended type or normally closed (no EOLR) operation via and maximum number of detectors supported. cut jumper. (Cut red jumper for normally closed operation. Do not cut for Fire Usage). Zones 2-8 5. Cut blue jumper to disable supervision of alarm sounder output. may be selected for either operation via program Leave jumper intact to supervise output. (See Installation and field *41. Setup Guide for Programming and Wiring Instructions). 2. Zone 1 supports 2-wire smoke detectors. See Installation and Setup Guide for recommended type and maximum number of detectors supported. 6. Zone 9 may be used for RS232 input. BATTERY 3. Zone 7 may be used for remote keyswitch TABS arming/disarming. See Installation and Setup Guide for wiring instructions. Red Jumper (note 1) (B TIP RO WN NOTES: (note 6) 30 EARTH GROUND Connect to good earth ground to maintain immunity to transients. See Instructions for proper grounding. DOC LOAD NO.: 5 WARNING: TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK BEFORE SERVICING THIS PANEL. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72 (NATIONAL FIRE PROTECTION ASSOC., BATTERYMARCH PARK. QUINCY, MA. 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION, TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS Polling loop rating: 128mA max. See Installation and Setup Guide for COMPLIES WITH FCC RULES, PART 68 maximum number of devices supported FCC REGISTRATION NO. AC398U-68192-AL-E and maximum wire run length RINGER EQUIVALENCE: 0.7B CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITED ONLY WITH THE APPROVAL OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER. THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. V128BP-SOC-V0 VISTA-128BP Summary of Connections Diagram WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. 4 5 6 7 8 9 10 TRANSFORMER 16.5VAC, 40VA ADEMCO No.1361 (IN CANADA USE No. 1361CN) or 4300 IF X-10 DEVICES WILL BE USED NOTE: WHEN POWERING UP THE PANEL, PLUG THE TRANSFORMER IN BEFORE CONNECTING THE BATTERY. ASSEMBLED IN MEXICO 13 ZONE 4 ZONE 5 14 15 16 ZONE 6 ZONE 7 17 18 19 21 22 23 - Red Blk Grn Yel REMOTE KEYPAD Use 6137/6128 or 6139 (Addressable keypads) only See Installation Instructions for max # of keypads and for max wire run length. BELL + - SIREN + + - AUXILARY POWER OUTPUT 9.6VDC - 13.8VDC, 750mA maximum Note: Include current drawn by keypads and polling loop devices when making auxiliary power calculations. 24 + + N.C. - - + + - N.C. N.C. + N.C. N.O. N.O. N.O. N.O. 2k EOLR (note 1) 2k EOLR (note 1) 2k EOLR (note 1) 2k EOLR (note 1,3) + Fire Usage N.C. SMOKE - + + N.C. N.O. N.C. Burg. Usage 2k EOLR (note 1) ALARM SOUNDER OUTPUT 10VDC - 13.8VDC N.O. Notes For UL Household Zone resistance (Excluding EOLR): Fire Installations ZONE 1,8: 100 OHMS MAXIMUM 2k EOLR 1. Use 12VDC, 14AH battery ALL OTHER ZONES: 300 OHMS MAXIMUM (note 1,2) 2. Maximum auxiliary current, Zone response time: including polling loop 300mA ZONES 1: 350mSec-500mSec 3. Combined alarm and auxilary power output and polling loop current must be limited to 750mA for UL985 Household Fire Installations. ALL CIRCUITS ARE POWER LIMITED. VISTA-250BP SUMMARY OF CONNECTIONS 2k EOLR (note 1,4) - 26 Handset 28 27 4208U RPM N.C. 4192SD SMOKE N.C. 4191SN PIR (note 6) 29 Incoming Phone Line Telephone connections using Ademco No. 620 RJ31X direct connect cord. + N.O. N.O. 2k EOLR (note 1) - GLASS BREAK N.C. 25 POLLING LOOP + MAKE CONNECTIONS USING No. 4142TR CABLE J8 1 2 3 4 5 6 7 8 9 J7 1 2 3 4 5 6 7 8 9 ZONE 8 ZONE 9 20 LATCHING TYPE GLASS BREAK DETECTOR LOOP Connect to 24hr. 120VAC, 60 Hz Outlet 2-WIRE SMOKE DETECTOR LOOP (Also supports NO/NC Burg contacts) — 71 — Replace every 3 years 12 ZONE 1 Data in See Installation and Setup Guide for required capacity 11 (G TIP RE EN ) RI (R NG ED ) 3 J7 Header J8 Header 1. I n 2 (Printer DTR) Optional programming: 1. Not Used Out 1: Smoke Detector Reset 2. Ground 2. GroundOut 2: Armed LED 3. Out 1 (Ground Start) 3. In 3 (4300 sync) Out 4: Ready LED 4. In 4 (4300 sync) 4. GroundRatings for Out 1: 5. Ground 5. Out 2 (fire) 6. Out 5 (4300 data) Active: 10VDC-13.8VDC through 4k OHMS 6. Ground7. Out 3 (burg/aud. panic) 7. Out 6 (Printer RXD) Not Active: 100 OHMS to ground Ratings for out 2-4: 8. Ground 8. Ground Active: 10VDC-13.8VDC through 5k OHMS 9. Ground 9. Out 4 (silent panic/ Not Active: 1k OHMS to ground duress) (Refer to Installation and Setup Guide for information concerning Direct Wire Downloading and printer connections.) ) R (G ING RA Y) 2 Data out CHARGING VOLTAGE 13.7VDC ZONE 2 ZONE 3 1 NO CONNECTION GEL CELL BATTERY RED (+) Connect to 12VDC, 4AH or 12VDC, 7AH BLK (-) Blue Jumper (note 5) 4. Zone 8 supports 2-wire latching type glass break detectors. 1. Zone 1 may be selected for EOLR supervised See Installation and Setup Guide for recommended type or normally closed (no EOLR) operation via and maximum number of detectors supported. cut jumper. (Cut red jumper for normally closed operation. Do not cut for Fire Usage). Zones 2-8 5. Cut blue jumper to disable supervision of alarm sounder output. may be selected for either operation via program Leave jumper intact to supervise output. (See Installation and field *41. Setup Guide for Programming and Wiring Instructions). 2. Zone 1 supports 2-wire smoke detectors. See Installation and Setup Guide for recommended type and maximum number of detectors supported. 6. Zone 9 may be used for RS232 input. BATTERY 3. Zone 7 may be used for remote keyswitch TABS arming/disarming. See Installation and Setup Guide for wiring instructions. Red Jumper (note 1) (B TIP RO WN NOTES: 30 EARTH GROUND Connect to good earth ground to maintain immunity to transients. See Instructions for proper grounding. DOC LOAD NO.: 5 WARNING: TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK BEFORE SERVICING THIS PANEL. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72 (NATIONAL FIRE PROTECTION ASSOC., BATTERYMARCH PARK. QUINCY, MA. 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION, TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS Polling loop rating: 128mA max. COMPLIES WITH FCC RULES, PART 68 See Installation and Setup Guide for maximum number of devices supported FCC REGISTRATION NO. AC398U-68192-AL-E and maximum wire run length RINGER EQUIVALENCE: 0.7B CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITED ONLY WITH THE APPROVAL OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER. THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. V250BP-SOC-V0 VISTA-250BP Summary of Connections Diagram WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED 165 Eileen Way, Syosset, New York 11791 Copyright © 2002 PITTWAY CORPORATION ¬.3590l K5894PRV2 9/02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseThumbs XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Producer : Acrobat Distiller 4.05 for Windows Create Date : 2003:06:09 16:10:09Z Modify Date : 2011:05:13 08:54:26-05:00 Metadata Date : 2011:05:13 08:54:26-05:00 Creator Tool : PSCRIPT.DRV Version 4.0 Format : application/pdf Title : Microsoft Word - K5894PRV2_pg.doc Document ID : uuid:7464ac1c-0ce5-40f7-89f6-4d4ce04a298d Instance ID : uuid:6e8c643e-1eb3-4cc2-8a95-49cb984a6d28 Page Count : 72 Page Layout : SinglePage Creator : PSCRIPT.DRV Version 4.0EXIF Metadata provided by EXIF.tools