LT 0757 WD 4 05 XR 2500F Wiring Diagram
User Manual: XR-2500F Wiring Diagram AlarmHow.net Library
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
Model XR2500F Wiring Diagram Refer to XR2500F Installation Guide (LT-0759) for a complete description of wiring connections. Refer to XR500 Series Programming Guide (LT-0679) for complete programming instructions. Refer to XR2500F User's Guide (LT-0760) for complete user instructions. WARNING THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION FEATURE THAT RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ). Zones 9, 10, and all expanded zones are suitable for Class B (as applicable for the initiating and signaling line circuits per UL 864 Table 48.2 or 48.3). Installation limits under local Authority Having Jurisdiction (AHJ). Verification Control Unit Delay Zones 13.6 sec. ______ Smoke Model ______ Detector Delay ____sec. S WHITE Wire into a 120 VAC 60 Hz outlet not controlled by a switch with at least 1.85 Amps of available current. BLACK GREE N S 866 Module #1 WHITE WHITE BLACK GREEN To Telco = Supervised Wire 28 VAC Transformer BLACK 16 VAC Transformer See LT-0759, 893A Dual Phone Line Module section for complete 893A information. S 866 Module #2 See LT-0759, Two 866 NAC Modules section for complete 866 information. 56 VA Transformer charges 4 batteries S S S S 504-24 Power Supply 893A S S 10K EOL To Notification Appliances 10K EOL + DC - See LT-0759, 504-12 Power Supply section for complete 504-12 information. P10 AC TRBL BATT TRBL J3 Phone Line Suitable for Grade AA Central Station with NET communications. NFPA 72 This equipment should be installed in accordance with Chapter 11 of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this equipment. RS-232 J22 Output 1 OVC Output 2 J2 J10 K6 J8 PROG AC AC +B 1 2 From XR2500F panel to 12 VDC. 3 K7 –B BELL GND RED YEL GRN BLK SMK GND Z1 GND Z2 4 5 6 7 8 9 10 11 + 12 13 14 3 4 5 6 J1 J16 Reset Outputs 3-6 Z3 GND Z4 15 16 17 - 20 Expansion Zones Z7 GND Z8 Z9+ Z9– Z10+ Z10– 21 22 23 24 25 26 27 28 Two 12 VDC batteries connected in parallel with a Model 318 Dual Battery Harness. See Secondary Power Supply section. Replace every 3 to 5 years. 12 VDC battery 12 VDC battery + 504-24 Secondary Power Supply 1.5 Amps maximum charge current. Use only 24 VDC rechargeable batteries or Two 12 VDC batteries with a Series Connecting Strap. Replace every 3 to 5 years. - + XR2500F Secondary Power Supply 1 Amp maximum charge current. Use only 12 VDC rechargeable batteries. 12 VDC battery Z5 GND Z6 18 19 To Fire Command Center on enclosure door Black Suitable for manual fire alarm, automatic fire alarm, sprinkler supervisory, or water flow alarm. J21 J23 Battery Start Red Suitable for Proprietary, PPU, other technologies, local. J1 Ethernet R L X From 504-24 Power Supply to 24 VDC. Suitable for Grade AA High Line Central Station with NET communication. Power LED XR2500F Command Processor™ Panel J4 Tamper Link LED Power LED Suitable for Remote Station PPU DACT Service. Suitable for manual fire alarm, automatic fire alarm, sprinkler supervisory, or water flow alarm. Black wire to negative battery terminal. Out1 Out2 Black TYPES OF SERVICE Central Station DACT service may be provided. + Bat - Red wire to positive battery terminal. J6 Expansion Card Slot AC Red 24 VDC Circuit Refer to LT-0759, Standby Battery Selection section for battery standby times and numbers of batteries to use. Battery Compartment - + Two 12 VDC batteries connected in series with the included Series Connecting Strap. See Secondary Power Supply section. 12 VDC battery LT-0757 (4/05) © 2005 Digital Monitoring Products, Inc.
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.4 Linearized : Yes Create Date : 2005:04:04 11:05:44-05:00 Creator : Adobe Illustrator 9.0 Modify Date : 2006:06:17 14:15:24-05:00 Creator Version : 9 Container Version : 9 For : Kelly Grist, DMP Bounding Box : 12 11 600 782 Page Count : 1 Page Mode : UseThumbs Creation Date : 2005:04:04 11:05:44-05:00 Producer : Adobe PDF library 4.800 Mod Date : 2005:10:24 11:44:50-04:00 Metadata Date : 2005:10:24 11:44:50-04:00 Title : LT-0757 WD 4-05.pdf Image Height : 771 Image Width : 588 Image Size : 588x771 Megapixels : 0.453EXIF Metadata provided by EXIF.tools