Model XR2500F Wiring Diagram

Refer to XR2500F Installation Guide (LT-0759) for a complete description of wiring connections.
Refer to XR500 Series Programming Guide (LT-0679) for complete programming instructions.
Refer to XR2500F User's Guide (LT-0760) for complete user instructions.
WARNING
THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION FEATURE THAT
RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60
SECONDS. NO OTHER SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS
UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).

Zones 9, 10, and all expanded zones are suitable for Class B (as applicable
for the initiating and signaling line circuits per UL 864 Table 48.2 or 48.3).
Installation limits under local Authority Having Jurisdiction (AHJ).
Verification Control Unit
Delay
Zones
13.6 sec.
______

Smoke
Model
______

Detector
Delay
____sec.

S

WHITE

Wire into a 120 VAC 60 Hz
outlet not controlled by a
switch with at least 1.85
Amps of available current.

BLACK

GREE
N

S

866
Module
#1

WHITE

WHITE
BLACK

GREEN

To Telco

= Supervised Wire

28 VAC
Transformer

BLACK

16 VAC
Transformer

See LT-0759, 893A
Dual Phone Line
Module section
for complete 893A
information.

S

866
Module
#2

See LT-0759, Two 866
NAC Modules section for
complete 866 information.

56 VA Transformer
charges 4 batteries

S

S

S

S

504-24
Power Supply

893A

S
S

10K EOL

To Notification
Appliances

10K EOL

+ DC -

See LT-0759, 504-12 Power
Supply section for complete
504-12 information.

P10

AC TRBL BATT TRBL

J3
Phone
Line

Suitable for Grade AA Central
Station with NET
communications.
NFPA 72
This equipment should be
installed in accordance with
Chapter 11 of the National
Fire Alarm Code, ANSI/NFPA
72-2002, (National Fire
Protection Association,
Batterymarch Park, Quincy,
MA 02269). Printed
information describing proper
installation, operation,
testing, maintenance,
evacuation planning, and
repair service is to be
provided with this equipment.

RS-232

J22

Output 1 OVC Output 2

J2

J10
K6

J8
PROG

AC AC +B
1

2

From XR2500F
panel to 12 VDC.

3

K7

–B BELL GND RED YEL GRN BLK SMK GND Z1 GND Z2
4

5

6

7

8

9

10

11

+

12 13

14

3
4
5
6

J1

J16
Reset

Outputs 3-6
Z3 GND Z4

15 16

17

-

20

Expansion Zones

Z7 GND Z8 Z9+ Z9– Z10+ Z10–

21 22

23

24 25

26

27

28

Two 12 VDC batteries
connected in parallel with a
Model 318 Dual Battery
Harness. See Secondary
Power Supply section.

Replace every 3 to 5 years.

12 VDC battery

12 VDC battery

+
504-24 Secondary Power Supply
1.5 Amps maximum charge current.
Use only 24 VDC rechargeable batteries
or Two 12 VDC batteries with a Series
Connecting Strap.
Replace every 3 to 5 years.

-

+

XR2500F Secondary Power Supply
1 Amp maximum charge current.
Use only 12 VDC rechargeable batteries.

12 VDC battery

Z5 GND Z6

18 19

To Fire Command Center on enclosure door

Black

Suitable for manual fire
alarm, automatic fire alarm,
sprinkler supervisory, or
water flow alarm.

J21
J23

Battery
Start

Red

Suitable for Proprietary, PPU,
other technologies, local.

J1
Ethernet

R
L
X

From 504-24 Power Supply to 24 VDC.

Suitable for Grade AA High
Line Central Station with NET
communication.

Power
LED

XR2500F
Command
Processor™
Panel

J4
Tamper

Link LED
Power LED

Suitable for Remote Station
PPU DACT Service. Suitable
for manual fire alarm,
automatic fire alarm,
sprinkler supervisory, or
water flow alarm.

Black wire to negative
battery terminal.

Out1 Out2

Black

TYPES OF SERVICE
Central Station DACT service
may be provided.

+ Bat -

Red wire to positive
battery terminal.

J6 Expansion
Card Slot

AC

Red

24 VDC
Circuit

Refer to LT-0759, Standby
Battery Selection section
for battery standby times and
numbers of batteries to use.
Battery Compartment

-

+

Two 12 VDC batteries
connected in series with the
included Series Connecting
Strap. See Secondary
Power Supply section.

12 VDC battery

LT-0757 (4/05) © 2005
Digital Monitoring Products, Inc.



Source Exif Data:
File Type                       : AI
File Type Extension             : ai
MIME Type                       : application/vnd.adobe.illustrator
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2005:04:04 11:05:44-05:00
Creator                         : Adobe Illustrator 9.0
Modify Date                     : 2006:06:17 14:15:24-05:00
Creator Version                 : 9
Container Version               : 9
For                             : Kelly Grist, DMP
Bounding Box                    : 12 11 600 782
Page Count                      : 1
Page Mode                       : UseThumbs
Creation Date                   : 2005:04:04 11:05:44-05:00
Producer                        : Adobe PDF library 4.800
Mod Date                        : 2005:10:24 11:44:50-04:00
Metadata Date                   : 2005:10:24 11:44:50-04:00
Title                           : LT-0757 WD 4-05.pdf
Image Height                    : 771
Image Width                     : 588
Image Size                      : 588x771
Megapixels                      : 0.453
EXIF Metadata provided by EXIF.tools

Navigation menu