Xtreme XPRT SNMP Internal Card Brochure

User Manual: Xtreme XPRT-SNMP Internal Card Brochure Xtreme s

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadXtreme XPRT-SNMP Internal Card Brochure
Open PDF In BrowserView PDF
HARDWARE SPECIFICATIONS

NET LOGIC

CPU

SAMSUNG S3C4510B 16/32-bit RISC microcontroller

Memory

Flash Memory – 16Mbits
SDRAM – 128Mbits

Ethernet Connector

10/100 BaseT RJ-45, auto switch

Power Input and Consumption

12V DC regulated, power consumption under 3 watts

Size

118 mm (L) x 89 mm (W) x 23 mm( H)

Network Interface

UTP Fast Ethernet 10/100BastT RJ-45, auto-sense

Display

Power, Diagnostic, TxD and RxD LEDs

Serial Port

Two high speed RS-232 ports. One used as a console port or connected to a MODEM allowing PPP dial-in
and paging, another is golden finger type serial port and connected to UPS

Extension Port

Connected to an extended device such as environment measurement through I2C

Real Time Clock

Time can be adjusted by SNTP

Firmware Upgradeable

Upgrades firmware via a web browser or TFTP

Telnet Management

Allows management via telnet

SNMP Network Management

Supports both SNMP v1 and v2. Supports RFC 1213 (MIB-II), RFC 1628 (UPS MIB) , and private UPS
extension MIB. Compatible with any standard SNMP NMS such as HP OpenView, IBM NetView

Web Network Management

Supports HTTP 1.0 protocol. Combined with HTML, JavaScript and Java Applet

Setup/Configuration

Allows setup via telnet or console

Operating Environment

0 to 60ºC

SNMP
Card

SNMP Communications Schematic

U
9

PIN 1

T1

D2

J5

U
10

U1

U2

U1: S3C4510B – Samsung 16/32 bits MCU
U2: Altima AC101 or AM79C874 – Ethernet Transceiver
U9: K4S281632D – 128Mbit SDRAM
U10: MX29LV160T – Flash Memory
J1: 10/100BaseT RJ-45 Phone Jack
J2: Modem or console port
J5: Extension Port
D2: Power/Diagnostic, Network Tx/Rx LEDs

J1

J2

Ordering Information: NET Logic SNMP Card, Model No: XPRT-SNMP1 or XVRT-SNMPB

Xtreme Power Conversion Corporation
920 Bay Vista Blvd. • Englewood, Fl 34223
Tel: 800.582.4524
www.xpcc.com

DO YOU REQUIRE XTREME SNMP CONNECTIVITY?
SNMP (Simple Network Management
Protocol) is used widely in the network
management field. With the support for
SNMP, the .NETpower software user
interface turns the UPS into an industrial
standard managed network device. You
can use an SNMP NMS (such as HP
OpenView or a IBM NetView) to manage
your UPS over a LAN or the Internet.

Moreover, the Net Logic SNMP card
will create a standard browser interface
for the UPS. This browser interface
allows easy viewing, management and
control of the UPS. In addition to the
network management function, it will
notify you when an event occurs, and
even shut down multiple systems on
the LAN.

Information Management

•

•

Network Interface

information and status of the UPS locally or remotely. It

Serial Port

presents the information in graphical formats from different

Used as a console port or connected to a MODEM allowing PPP dial-in and paging

•

Extension Port

•

Real Time Clock

•

Setup/Configuration

Connected to an extended device such as environment measurement

Time can be adjusted by SNTP

Allows setup via telnet or console

•

Firmware Upgradeable

•

Multiple System Shutdown

•

Event Notification

•

SNMP Network Management

•

The .NETpower interface allows you to view the

UTP Fast Ethernet 10/100 auto-sense

Upgrades firmware via a web browser or TFTP

points of view: inside activity, power meters, and scope
charts.
The .NETpower interface maintains two log files
• an event log file which contains all UPS related events
such as power failures, shutdowns, power recoveries,
etc.
• a data log file: which is a collection of the UPS power
quality, including input voltage, output voltage, battery
voltage, temperature, etc.

Sends a shutdown signal to shut down multiple systems on LAN

OnEvent

Includes network message, OnEvent multimedia message, email and page

OnEvent is a new notification technology which can exchange multimedia

Supports SNMP v1.0 and v2.0. Supports RFC 1213 (MIB-II), RFC 1628 (UPS MIB),
and private UPS extension MIB. Compatible with any standard SNMP NMS such as
HP OpenView and IBM NetView

messages over a LAN, regardless of operating system. When a power event

Web Network Management

the system when receiving a shutdown signal from the NETLogic card. It also

occurs, a multimedia message box will be displayed on each computer with
OnEvent software installed. It is also a shutdown agent which will shut down

Supports HTTP 1.0 protocol. Combined with HTML, Java Script and Java Applet

•

Telnet Management

•

Graphic Information Management

•

Event Logging

serves as a shutdown agent when a shutdown signal is received from the
.Netlogic card.

Allows management via telnet

Includes Power Meter, Block Diagram, Power Scope, and Log Analysis

Contains all UPS-related events

Data Logging

A collection of the UPS power quality

Flexible Event Action
You can define actions for each event. The .NETpower interface will perform
actions according to your definitions when an event occurs. The actions
include logging, network notification, email, paging, executing command file,
and system shutdown.

Scheduling

Perform shutdown, startup, and self-test according to the scheduling settings

Flexible Event Action

Provides flexible event action feature

Scheduling
The .NETpower interface allows for a customizable UPS schedule setup for

UPS Control

automatic system shutdown/startups and self-tests.

UPS Configuration

Compatible Operating Systems
The SNMP CD is compatible with the following operating systems: FreeBSD,
Hpux, IBMaix, IBMos2, IRIX, Linux, Solsparc, Solx86, Windows

Allows you to shut down, reset, or restart the UPS remotely

Allows you to configure the UPS remotely

Password Security

Provides password protection

www.xpcc.com

www.xpcc.com

Information Management

•

•

Network Interface

information and status of the UPS locally or remotely. It

Serial Port

presents the information in graphical formats from different

Used as a console port or connected to a MODEM allowing PPP dial-in and paging

•

Extension Port

•

Real Time Clock

•

Setup/Configuration

Connected to an extended device such as environment measurement

Time can be adjusted by SNTP

Allows setup via telnet or console

•

Firmware Upgradeable

•

Multiple System Shutdown

•

Event Notification

•

SNMP Network Management

•

The .NETpower interface allows you to view the

UTP Fast Ethernet 10/100 auto-sense

Upgrades firmware via a web browser or TFTP

points of view: inside activity, power meters, and scope
charts.
The .NETpower interface maintains two log files
• an event log file which contains all UPS related events
such as power failures, shutdowns, power recoveries,
etc.
• a data log file: which is a collection of the UPS power
quality, including input voltage, output voltage, battery
voltage, temperature, etc.

Sends a shutdown signal to shut down multiple systems on LAN

OnEvent

Includes network message, OnEvent multimedia message, email and page

OnEvent is a new notification technology which can exchange multimedia

Supports SNMP v1.0 and v2.0. Supports RFC 1213 (MIB-II), RFC 1628 (UPS MIB),
and private UPS extension MIB. Compatible with any standard SNMP NMS such as
HP OpenView and IBM NetView

messages over a LAN, regardless of operating system. When a power event

Web Network Management

the system when receiving a shutdown signal from the NETLogic card. It also

occurs, a multimedia message box will be displayed on each computer with
OnEvent software installed. It is also a shutdown agent which will shut down

Supports HTTP 1.0 protocol. Combined with HTML, Java Script and Java Applet

•

Telnet Management

•

Graphic Information Management

•

Event Logging

serves as a shutdown agent when a shutdown signal is received from the
.Netlogic card.

Allows management via telnet

Includes Power Meter, Block Diagram, Power Scope, and Log Analysis

Contains all UPS-related events

Data Logging

A collection of the UPS power quality

Flexible Event Action
You can define actions for each event. The .NETpower interface will perform
actions according to your definitions when an event occurs. The actions
include logging, network notification, email, paging, executing command file,
and system shutdown.

Scheduling

Perform shutdown, startup, and self-test according to the scheduling settings

Flexible Event Action

Provides flexible event action feature

Scheduling
The .NETpower interface allows for a customizable UPS schedule setup for

UPS Control

automatic system shutdown/startups and self-tests.

UPS Configuration

Compatible Operating Systems
The SNMP CD is compatible with the following operating systems: FreeBSD,
Hpux, IBMaix, IBMos2, IRIX, Linux, Solsparc, Solx86, Windows

Allows you to shut down, reset, or restart the UPS remotely

Allows you to configure the UPS remotely

Password Security

Provides password protection

www.xpcc.com

www.xpcc.com

HARDWARE SPECIFICATIONS

NET LOGIC

CPU

SAMSUNG S3C4510B 16/32-bit RISC microcontroller

Memory

Flash Memory – 16Mbits
SDRAM – 128Mbits

Ethernet Connector

10/100 BaseT RJ-45, auto switch

Power Input and Consumption

12V DC regulated, power consumption under 3 watts

Size

118 mm (L) x 89 mm (W) x 23 mm( H)

Network Interface

UTP Fast Ethernet 10/100BastT RJ-45, auto-sense

Display

Power, Diagnostic, TxD and RxD LEDs

Serial Port

Two high speed RS-232 ports. One used as a console port or connected to a MODEM allowing PPP dial-in
and paging, another is golden finger type serial port and connected to UPS

Extension Port

Connected to an extended device such as environment measurement through I2C

Real Time Clock

Time can be adjusted by SNTP

Firmware Upgradeable

Upgrades firmware via a web browser or TFTP

Telnet Management

Allows management via telnet

SNMP Network Management

Supports both SNMP v1 and v2. Supports RFC 1213 (MIB-II), RFC 1628 (UPS MIB) , and private UPS
extension MIB. Compatible with any standard SNMP NMS such as HP OpenView, IBM NetView

Web Network Management

Supports HTTP 1.0 protocol. Combined with HTML, JavaScript and Java Applet

Setup/Configuration

Allows setup via telnet or console

Operating Environment

0 to 60ºC

SNMP
Card

SNMP Communications Schematic

U
9

PIN 1

T1

D2

J5

U
10

U1

U2

U1: S3C4510B – Samsung 16/32 bits MCU
U2: Altima AC101 or AM79C874 – Ethernet Transceiver
U9: K4S281632D – 128Mbit SDRAM
U10: MX29LV160T – Flash Memory
J1: 10/100BaseT RJ-45 Phone Jack
J2: Modem or console port
J5: Extension Port
D2: Power/Diagnostic, Network Tx/Rx LEDs

J1

J2

Ordering Information: NET Logic SNMP Card, Model No: XPRT-SNMP1 or XVRT-SNMPB

Xtreme Power Conversion Corporation
920 Bay Vista Blvd. • Englewood, Fl 34223
Tel: 800.582.4524
www.xpcc.com

DO YOU REQUIRE XTREME SNMP CONNECTIVITY?
SNMP (Simple Network Management
Protocol) is used widely in the network
management field. With the support for
SNMP, the .NETpower software user
interface turns the UPS into an industrial
standard managed network device. You
can use an SNMP NMS (such as HP
OpenView or a IBM NetView) to manage
your UPS over a LAN or the Internet.

Moreover, the Net Logic SNMP card
will create a standard browser interface
for the UPS. This browser interface
allows easy viewing, management and
control of the UPS. In addition to the
network management function, it will
notify you when an event occurs, and
even shut down multiple systems on
the LAN.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Instance ID                     : uuid:cc85ada0-2ffb-11dd-a19a-0017f2caae84
Document ID                     : adobe:docid:indd:90feb6e1-a179-11dc-866e-8ac0b2af38a3
Rendition Class                 : proof:pdf
Derived From Instance ID        : 90feb6e0-a179-11dc-866e-8ac0b2af38a3
Derived From Document ID        : adobe:docid:indd:90feb6df-a179-11dc-866e-8ac0b2af38a3
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 300.00
Manifest Placed Y Resolution    : 72.00, 300.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:33d9c180-a40b-11dc-b5e3-0017f2caae84, uuid:3FFCE4FD136911DDB869DAABEC2B958B
Manifest Reference Document ID  : uuid:DABEC8BFA25911DC83E7ED9FE08DDB58, uuid:9EA01BB7136211DD855BF39C4AD93BE2
Create Date                     : 2008:06:01 09:48:30-07:00
Modify Date                     : 2008:06:01 09:57:20-07:00
Metadata Date                   : 2008:06:01 09:57:20-07:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8598 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools

Navigation menu