H250 M40 Handbook Variable area flowmeter © KROHNE 07/2016 - 4000640704 - MA H250-M40 R04 en : IMPRINT ::::::::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of KROHNE Messtechnik GmbH. Subject to change without notice. Copyright 2016 by KROHNE Messtechnik GmbH - Ludwig-Krohne-Str. 5 - 47058 Duisburg (Germany) 2 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en CONTENTS H250 M40 1 Safety instructions 1.1 1.2 1.3 1.4 5 Intended use ..................................................................................................................... 5 Certifications .................................................................................................................... 6 Pressure equipment directive.......................................................................................... 6 Safety instructions from the manufacturer ..................................................................... 8 1.4.1 1.4.2 1.4.3 1.4.4 1.4.5 Copyright and data protection ................................................................................................ 8 Disclaimer ............................................................................................................................... 8 Product liability and warranty ................................................................................................ 9 Information concerning the documentation........................................................................... 9 Warnings and symbols used................................................................................................. 10 1.5 Safety instructions for the operator............................................................................... 10 2 Device description 11 2.1 Scope of delivery............................................................................................................. 11 2.2 Device version................................................................................................................. 12 2.2.1 Indicator versions ................................................................................................................. 13 2.2.2 Float damping ....................................................................................................................... 15 2.2.3 Pointer damping.................................................................................................................... 15 2.3 Nameplate ...................................................................................................................... 16 2.4 Description code............................................................................................................. 17 2.5 Electronic revision.......................................................................................................... 18 3 Installation 19 3.1 Notes on installation ...................................................................................................... 19 3.2 Storage ........................................................................................................................... 19 3.3 Installation conditions .................................................................................................... 20 3.3.1 Tightening torques ................................................................................................................ 22 3.3.2 Magnetic filters ..................................................................................................................... 22 3.3.3 Heat insulation ...................................................................................................................... 23 4 Electrical connections 24 4.1 Security information ....................................................................................................... 24 4.2 Electrical connection indicator M40............................................................................... 25 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 Limit switches K1/K2 ............................................................................................................ 25 ESK4 / ESK4A current output ............................................................................................... 28 ESK4-T limit outputs............................................................................................................. 31 ESK4-T pulse output ............................................................................................................. 33 ESK4-T binary input .............................................................................................................. 34 ESK4-FF / ESK4-PA fieldbus communication...................................................................... 35 Harting HAN 7D connection.................................................................................................. 36 4.3 Grounding connections................................................................................................... 37 4.4 Ingress protection .......................................................................................................... 37 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 3 CONTENTS H250 M40 5 Start-up 38 5.1 Standard device .............................................................................................................. 38 5.2 Indicator ESK4-T ............................................................................................................ 38 6 Operation 39 6.1 ESK4 / ESK4A - Loop Check Mode ................................................................................. 39 6.2 Operating elements ESK4-T........................................................................................... 40 6.3 Basic principles of operation ESK4-T ............................................................................ 41 6.3.1 Description of the operating keys......................................................................................... 41 6.3.2 Navigation within the menu structure.................................................................................. 41 6.3.3 Change the settings in the menu.......................................................................................... 42 6.4 Overview of the units ESK4-T ......................................................................................... 43 6.5 Error messages ESK4-T................................................................................................. 44 6.6 ESK4-T menu.................................................................................................................. 46 6.6.1 Factory settings .................................................................................................................... 46 6.6.2 Menu structure ..................................................................................................................... 47 6.6.3 Menu description .................................................................................................................. 49 7 Service 56 7.1 Maintenance ................................................................................................................... 56 7.2 Replacement and retrofitting......................................................................................... 56 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 Replacing floats .................................................................................................................... 56 Retrofitting float damping..................................................................................................... 57 Retrofitting limit switch ........................................................................................................ 57 Replacement - Retrofitting ESK4 / ESK4A ........................................................................... 58 Replacement - Retrofitting add-on module ESK4-T / PA / FF............................................. 59 7.3 Spare parts availability................................................................................................... 59 7.3.1 List of spare parts ................................................................................................................. 59 7.4 Availability of services .................................................................................................... 63 7.5 Returning the device to the manufacturer..................................................................... 63 7.5.1 General information.............................................................................................................. 63 7.5.2 Form (for copying) to accompany a returned device............................................................ 64 7.6 Disposal .......................................................................................................................... 64 8 Technical data 8.1 8.2 8.3 8.4 4 65 Functional principle........................................................................................................ 65 Technical data................................................................................................................. 66 Dimensions and weights ................................................................................................ 73 Measuring ranges........................................................................................................... 76 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SAFETY INSTRUCTIONS 1 H250 M40 1.1 Intended use CAUTION! Responsibility for the use of the measuring devices with regard to suitability, intended use and corrosion resistance of the used materials against the measured fluid lies solely with the operator. INFORMATION! This device is a Group 1, Class A device as specified within CISPR11:2009. It is intended for use in industrial environment. There may be potential difficulties in ensuring electromagnetic compatibility in other environments, due to conducted as well as radiated disturbances. INFORMATION! The manufacturer is not liable for any damage resulting from improper use or use for other than the intended purpose. The variable area flowmeters are suitable for measuring clean gases, vapours and liquids. Intended use: • The product may not contain any ferromagnetic particles or solids. It may be necessary to install magnetic filters or mechanical filters. • The product must be sufficiently liquid and free of deposits. • Avoid pressure surges and pulsing flows. • Open valves slowly. Do not use solenoid valves. Use suitable measures to eliminate compression vibrations during gas measurements: • • • • Short pipeline lengths to next restriction Nominal pipe size not greater than nominal device size Use of floats with damping Increase in operating pressure (while taking into account the resulting change in density and thus change in scale) Observe installation conditions according to VDI/VDE 3513-3. DANGER! For devices used in hazardous areas, additional safety notes apply; please refer to the Ex documentation. CAUTION! Do not use any abrasive media containing solid particles or highly viscous media. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 5 1 SAFETY INSTRUCTIONS H250 M40 1.2 Certifications CE marking The device fulfils all applicable statutory requirements of the EU directives: • Pressure equipment directive • For devices with electrical installations: EMC directive • Devices for use in hazardous areas: ATEX directive as well as • NAMUR recommendations NE 21, NE 43 and NE 107 The manufacturer certifies successful testing of the product by applying the CE mark. A EU declaration of conformity regarding the directives in question and the associated harmonised standards can be downloaded from our website. 1.3 Pressure equipment directive A conformity assessment in accordance with pressure equipment directive has been carried out for the devices described. Conformity is certified by applying the CE mark. The number of the notified body is also stated. The PED key describes the rating of the devices: Example: PED/G1/III/H G Gases and vapours 1 Fluid group 1 III Category III H Conformity assessment method according to Module H The PED key identification can be found on the nameplate of the device (for details refer to Nameplate on page 16). INFORMATION! The stated pressures (PS) and temperatures (TS) only apply as refers to the pressure resistance of the sensor body. As regards the functionality of the entire device, further restrictions of the maximum temperature may need to be observed (e.g. ATEX approval). Devices rated below category I due to their size, do not receive the CE mark in the scope of the PED. These devices are subject to applicable sound engineering practice (SEP). 6 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SAFETY INSTRUCTIONS 1 H250 M40 Residual risk A risk analysis in accordance with the pressure equipment directive has been carried out for the devices . The residual risk is described as follows: • The devices are designed according to the valid and applicable rules and standards for static operation and their pressure resistance is calculated for the declared maximum pressure and temperature (no calculation for cyclical change). • Responsibility for the use of the measuring devices with regard to corrosion resistance of the used materials against the measured fluid lies solely with the operator. • Avoid abrasion. • Avoid pulsation and cavitation. • Protect devices from vibration and high-frequency oscillation. • Draining (backflow) may be delayed due to the float in the measuring tube. • Implement appropriate measures to counteract external fire hazards 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 7 1 SAFETY INSTRUCTIONS H250 M40 1.4 Safety instructions from the manufacturer 1.4.1 Copyright and data protection The contents of this document have been created with great care. Nevertheless, we provide no guarantee that the contents are correct, complete or up-to-date. The contents and works in this document are subject to copyright. Contributions from third parties are identified as such. Reproduction, processing, dissemination and any type of use beyond what is permitted under copyright requires written authorisation from the respective author and/or the manufacturer. The manufacturer tries always to observe the copyrights of others, and to draw on works created in-house or works in the public domain. The collection of personal data (such as names, street addresses or e-mail addresses) in the manufacturer's documents is always on a voluntary basis whenever possible. Whenever feasible, it is always possible to make use of the offerings and services without providing any personal data. We draw your attention to the fact that data transmission over the Internet (e.g. when communicating by e-mail) may involve gaps in security. It is not possible to protect such data completely against access by third parties. We hereby expressly prohibit the use of the contact data published as part of our duty to publish an imprint for the purpose of sending us any advertising or informational materials that we have not expressly requested. 1.4.2 Disclaimer The manufacturer will not be liable for any damage of any kind by using its product, including, but not limited to direct, indirect or incidental and consequential damages. This disclaimer does not apply in case the manufacturer has acted on purpose or with gross negligence. In the event any applicable law does not allow such limitations on implied warranties or the exclusion of limitation of certain damages, you may, if such law applies to you, not be subject to some or all of the above disclaimer, exclusions or limitations. Any product purchased from the manufacturer is warranted in accordance with the relevant product documentation and our Terms and Conditions of Sale. The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable in any way for possible consequences of such changes. 8 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SAFETY INSTRUCTIONS 1 H250 M40 1.4.3 Product liability and warranty The operator shall bear responsibility for the suitability of the device for the specific purpose. The manufacturer accepts no liability for the consequences of misuse by the operator. Improper installation or operation of the devices (systems) will cause the warranty to be void. The respective "Standard Terms and Conditions" which form the basis for the sales contract shall also apply. 1.4.4 Information concerning the documentation To prevent any injury to the user or damage to the device it is essential that you read the information in this document and observe applicable national standards, safety requirements and accident prevention regulations. If this document is not in your native language and if you have any problems understanding the text, we advise you to contact your local office for assistance. The manufacturer can not accept responsibility for any damage or injury caused by misunderstanding of the information in this document. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of icons as shown below. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 9 1 SAFETY INSTRUCTIONS H250 M40 1.4.5 Warnings and symbols used Safety warnings are indicated by the following symbols. DANGER! This warning refers to the immediate danger when working with electricity. DANGER! This warning refers to the immediate danger of burns caused by heat or hot surfaces. DANGER! This warning refers to the immediate danger when using this device in a hazardous atmosphere. DANGER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operator's plant. WARNING! Disregarding this safety warning, even if only in part, poses the risk of serious health problems. There is also the risk of damaging the device or parts of the operator's plant. CAUTION! Disregarding these instructions can result in damage to the device or to parts of the operator's plant. INFORMATION! These instructions contain important information for the handling of the device. LEGAL NOTICE! This note contains information on statutory directives and standards. • HANDLING This symbol designates all instructions for actions to be carried out by the operator in the specified sequence. i RESULT This symbol refers to all important consequences of the previous actions. 1.5 Safety instructions for the operator WARNING! In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. 10 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en DEVICE DESCRIPTION 2 H250 M40 2.1 Scope of delivery INFORMATION! Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. INFORMATION! Do a check of the packing list to make sure that you have all the elements given in the order. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. Figure 2-1: Scope of delivery 1 2 3 4 5 Measuring device in ordered version For the ESK4-T version - bar magnet Documentation Certificates, calibration report (supplied to order only) Wrench 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 11 2 DEVICE DESCRIPTION H250 M40 2.2 Device version • H250 with indicator M40 • H250 with M40 indicator with display cut-out for ESK4-T 1. H250/RR/M40 • Local indicator without auxiliary power • Max. 2 limit switches, type NAMUR, NAMUR safety-oriented or transistor (3-wire) • Electrical signal output 4...20 mA, HART® or Fieldbus communication • Intrinsically safe (Ex i) or in explosion-proof enclosure (Ex d) 2. H250/RR/M40 • Additional LCD, measured value and/or flow counter • 2 configurable binary outputs, limit value or pulse output • 1 binary input, Start / Stop / Reset flow counter • 2-wire current output 4…20 mA, HART® communication • Intrinsically safe (Ex i) or in explosion-proof enclosure (Ex d) Optional versions: • • • • • • H250 with indicator M40 as high temperature version HT H250 with indicator M40 with increased corrosion protection (special paint finish) H250H for use in horizontal pipelines H250U for use in vertical fall pipes H250F with hygienic measuring tube design for Food & Pharma H250C with PTFE / TFM liner for aggressive media Display options • M40 - Aluminium, single-layer powder coating (polyester) • M40S - Aluminium, two-layer powder coating (epoxy / polyester) • M40R - Stainless steel without coating Offshore wet coating for aluminium or stainless steel on request 12 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en DEVICE DESCRIPTION 2 H250 M40 2.2.1 Indicator versions The M40 indicator can be fitted with various modules. Basic version 1 2 3 4 5 6 7 Pointer module Bolts for ESK4 / ESK4A attachment Baseplate Module profile Pressure piece for ESK4 / ESK4A attachment Housing cover locking device Earth terminal external Versions K1 / K2 and ESK4 / ESK4A 1 Indicator with K2 contact module 2 Indicator with ESK4 / ESK4A current output 4...20 mA Both versions can be combined with one another. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 13 2 DEVICE DESCRIPTION H250 M40 Version ESK4-T 1 2 3 4 5 6 7 ESK4 / ESK4A connection Module cover Display Display module ESK4-IO Operating keys ^ ↑ Connection binary outputs and reset input Module connection cable Version Fieldbus ESK4-FF / ESK4-PA 1 Basic module with electronic magnet sensors ESK4 / ESK4A 2 Connection bus module 3 DIP switch for bus settings For more details see the supplementary instructions "H250 M40 Foundation Fieldbus" and "H250 M40 Profibus PA" 14 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en DEVICE DESCRIPTION 2 H250 M40 2.2.2 Float damping Float damping is characterised by high standstill times and self-centering. The damping sleeve is made of high performance ceramic or PEEK, depending on the medium and the application. Float damping can also be retrofitted for the user (refer to "Service"). Use of damping • Generally when CIV and DIV floats are used for gas measurement. • For TIV floats (H250/RR and H250/HC only) with an operating primary pressure: Nominal size acc. to Operating primary pressure EN 1092-1 ASME B16.5 [bar] [psig] DN 50 ½" ≤0.3 ≤4.4 DN25 1" ≤0.3 ≤4.4 DN50 2" ≤0.2 ≤2.9 DN80 3" ≤0.2 ≤2.9 DN 100 4" ≤0.2 ≤2.9 2.2.3 Pointer damping In principle, the indicating element with its magnetic system contains indicator damping. An additional eddy current brake is advantageous in the event of fluctuating or pulsing flows. The magnets on the eddy current brake surround the pointer vane without touching it, damping its movement. The result is a much steadier pointer position, without distorting the measured value. A turnbuckle ensures a proper fit. The eddy current brake can be retrofitted during operation without recalibrating (refer to "Service"). 1 2 3 4 Eddy current brake Pointer vane Bracket Pointer cylinder 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 15 2 DEVICE DESCRIPTION H250 M40 2.3 Nameplate INFORMATION! Check on the device nameplates, that the device is supplied according to your order. 0035 0102 H250/.././M40/..-Ex P/A: 011123456.001 MD:201x PED/G1/II/H PS: xxx bar PTmax: xxx bar TS: xx °C Tag-No.: PTB 11 ATEX 2012 X II2G Ex ia IIC T6 IECEx PTB 11.0069 X Tamb: -20°C... +60°C (T6: +40°C) Ui = xxV Ci = xxnF Ii = xxmA Li = xuH Pi = xW Ii = xxmA Li = xuH Pi = xW Kmin1 Ui = xxV Ci = xxnF Ui = xxV Ci = xxnF Ii = xxmA Li = xuH Pi = xW Kmin2 ESK... www.krohne.com Figure 2-2: Nameplate on the indicator 1 2 3 4 5 6 7 8 Device type Manufacturer Notified body ATEX & PED Rating data: temperature & pressure rating PED data Ex data Electrical connection data Internet site Additional markings on the indicator • • • • • 16 SN - serial number SO - sales order / item PA - production order Vx - product configurator code AC - article code www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en DEVICE DESCRIPTION 2 H250 M40 2.4 Description code The description code* consists of the following elements: 1 Device type H250 - standard version H250H - horizontal flow direction H250U - flow direction from top to bottom 2 Materials / versions RR - stainless steel C - PTFE or PTFE/ceramics HC - Hastelloy® Ti - Titanium Mo - Monel F - aseptic version (food) 3 Heating jacket version B - with heating jacket 4 Type series of indicators M40 - Indicator M40 M40S - indicator with increased corrosion protection M40R - indicator in stainless steel housing 5 High temperature version HT - version with HT extension 6 Electrical signal output ESK - electrical signal output 4...20 mA (ESK4 / ESK4A) - optionally available with counter, I/O module and display (ESK4-T) or - Foundation Fieldbus (ESK4-FF) or - Profibus PA (ESK4-PA) 7 Limit switches K1 - one limit switch K2 - two limit switches 8 Explosion protection Ex -explosion proof equipment 9 SIL version SE - SIL compliant electronic signal output SK - SIL compliant limit switch * positions which are not needed are omitted (no blank positions) 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 17 2 DEVICE DESCRIPTION H250 M40 2.5 Electronic revision The electronic revision (sticker on the base module ESK4 / ESK4A) indicates the respective hardware/software status of the electronics. All add-on modules (ESK4-T, ESK4-FF and ESK4PA) have an additional sticker indicating their respective firmware version. Electronic revision Explanations ER 1.1.x Basic version (cannot be combined with other indicator versions): ESK4 / current output 4…20 mA with HART® communication (ESK4 HART DD 01.01. AMS10x AMS11x ESK4 HART DD 01.01. PDM6.0 ESK4 HART DTM 1.0.3 FDT1.2) ER 2.0.x Functional add-on to ER 1.1.x: can be combined with indicator version ESK4 FF / Foundation Fieldbus; (Firmware version FF module from 1.0.2) ER 2.1.x Functional add-on to ER 2.0.x can be combined with indicator version ESK4-PA / Profibus PA (Firmware version PA module from 1.0.0) can be combined with indicator version ESK4-T / LCD, binary inputs/outputs (Firmware version T module from 1.1.0) ER 2.2.x Functional add-on to ER 2.1.x: Support of failure signal (low) according to NE 43 for the ESK4 current output module ER 3.0.x Functional add-on: Update for HART® communication from 5.9 to 7.4 including new DD/DTM can be combined with ESK4-FF (Firmware version FF module from 1.0.2) Firmware Version ESK4-PA (... PA module from 1.0.0) Firmware Version ESK4-T (... T module from 1.2.0) 18 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en INSTALLATION 3 H250 M40 3.1 Notes on installation INFORMATION! Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. INFORMATION! Do a check of the packing list to make sure that you have all the elements given in the order. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Storage • • • • Store the device in a dry, dust-free location. Avoid lasting direct exposure to the sun. Store the measuring device in the original packaging. The permissible storage temperatures for standard devices are: -40...+80°C / -40...+176°F 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 19 3 INSTALLATION H250 M40 3.3 Installation conditions CAUTION! When installing the device in the piping, the following points must be observed: • The variable area flowmeter must be installed vertically (measuring principle). Flow direction • • • • • • • • • • • • 20 from bottom to top. For installation recommendations please refer also to directive VDI/VDE 3513, sheet 3. H250Hs are installed horizontally and H250U devices are installed vertically with the flow direction from top to bottom. A straight unimpeded inlet run of ≥ 5 DN upstream of the device and a straight outlet run of ≥ 3 DN downstream of the device are recommended. Screws, bolts and gaskets are to be provided by the customer and must be selected in accordance with the pressure rating of the connection or the operating pressure. The inside diameter of the flange deviates from the standard dimensions. Flange seal standard DIN 2690 can be applied without any limitation. Align the gaskets. Tighten the nuts with the tightening torques of the appropriate pressure rating. For devices with PTFE liner or ceramic liner and PTFE raised faces, refer to chapter "Tightening torques". Control devices are to be positioned downstream of the measuring device. Shutoff devices are preferably to be positioned upstream of the measuring device. Before connecting, blow or flush out the pipes leading to the device. Pipes for gas flow need to be dried before the device is installed. Use connectors suitable for the particular device version. Align the pipes centrically with the connection bores on the measuring device so they are free of stresses. If necessary, the piping has to be supported to reduce the vibrations transmitted to the measuring device. Do not lay signal cables directly next to cables for the power supply. www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en INSTALLATION 3 H250 M40 Minimum distance between devices When several devices are installed next to one another, a minimum distance of a > 300 mm / 11.8" between the devices is necessary. Take special note of the installation position for the H250H with horizontal flow direction: In order to comply with thermal parameters and measuring accuracy, H250H flowmeters for horizontal installation are to be installed in the pipeline so that the display is located on the side of the measuring tube. The maximum product and ambient temperatures indicated as well as the measuring accuracy are based on lateral installation of the display. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 21 3 INSTALLATION H250 M40 3.3.1 Tightening torques For measuring devices with PTFE liner or ceramic liner and PTFE raised face, tighten the flange threads with the following torques: Nominal size acc. to EN 1092-1 DN PN Stud bolts ASME B16.5 Inch EN lb Max. torque ASME 150 lb 300 lb EN 1092-1 Nm ASME 150 lb ft*lbf Nm ft*lbf 15 40 ½" 150/300 4x M12 4x ½" 4x ½" 9.8 7.1 5.2 3.8 25 40 1" 150/300 4x M12 4x ½" 4x 5/8" 21 15 10 7.2 50 40 2" 150/300 4x M16 4x 5/8" 8x 5/8" 57 41 41 30 80 16 3" 150/300 8x M16 4x 5/8" 8x ¾" 47 34 70 51 100 16 4" 150/300 8x M16 8x 5/8" 8x ¾" 67 48 50 36 3.3.2 Magnetic filters The use of magnetic filters is recommended when the medium contains particles which can be influenced magnetically. The magnetic filter is to be installed in the flow direction upstream of the flowmeter. Bar magnets are positioned helically in the filter to provide optimal efficiency at low pressure loss. All of the magnets are coated individually with PTFE to protect against corrosion. Material: 1.4404/316L Magnetic filters 1 Type F - fitting part with flange - overall length 100 mm / 4" 2 Type FS - fitting part without flange - overall length 50 mm / 2" 22 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en INSTALLATION 3 H250 M40 3.3.3 Heat insulation CAUTION! The indicator housing may not be heat-insulated. The heat insulation 3 may only reach to the housing mounting 4. 1 Standard indicator M40 2 Indicator with HT extension CAUTION! The heat insulation 1 may only reach to the rear of the housing 2. The area around the cable entries 3 must be freely accessible. Figure 3-1: Insulation - cross section 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 23 4 ELECTRICAL CONNECTIONS H250 M40 4.1 Security information DANGER! All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! DANGER! Observe the national regulations for electrical installations! DANGER! For devices used in hazardous areas, additional safety notes apply; please refer to the Ex documentation. WARNING! Observe without fail the local occupational health and safety regulations. Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 24 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 4.2 Electrical connection indicator M40 4.2.1 Limit switches K1/K2 The M40 indicator can be fitted with a maximum of two limit switches. The limit switch works as a slot sensor which is inductively activated via the semi-circular metal vane of the pointer. The switching points are set using the contact pointers. The position of the contact pointers is indicated on the scale. Limit switch module 1 2 3 4 5 Min. contact Max. contact Locking screw Maximum pointer Connection terminal The connection terminals have a pluggable design and can be removed to connect the cables. The built-in limit switch types are shown on the nameplate of the indicator. Electrical connection of the limit switches Contact MIN MAX Terminal no. 1 2 Connection 2-wire NAMUR - + Connection 3-wire + - + - Connection Reed SPST + - + - 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 3 4 5 - + 6 25 4 ELECTRICAL CONNECTIONS H250 M40 Limit switch connection terminals 1 2 3 4 5 6 7 8 2-wire limit switch NAMUR 3-wire limit switch Limit switch Reed SPST Terminal connection of Min. contact Terminal connection of Max. contact 3-wire load NAMUR isolated switching amplifier 3-wire power supply Limit setting Figure 4-1: Limit switch settings 1 Contact pointer MAX 2 Contact pointer MIN 3 Locking screw Setting is carried out directly via contact pointers 1 and 2: • • • • Slide the scale aside. Loosen the locking screw 3 slightly. Slide the scale back to the latching point. Set contact pointers 1 and 2 to the desired switching point. After setting: Fix the contact pointers with the locking screw 3. 26 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 Switch contact definition 1 MIN contact 2 MAX contact 3 Pointer vane with switching vane If the pointer vane goes into the slot, an alarm is triggered. If the pointer vane is outside of the proximity switch, a wire break in a NAMUR contact also triggers the alarm. The 3-wire limit switch does not have any wire break detection. Definition MinMin - MaxMax 1 MIN 2 contact or MAX 1 contact 2 MIN 1 contact or MAX 2 contact Current consumption in the position shown: Contact Type Current MIN 1 NAMUR ≤ 1 mA MIN 2 NAMUR ≤ 1 mA MAX 1 NAMUR ≥ 3 mA MAX 2 NAMUR ≥ 3 mA 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 27 4 ELECTRICAL CONNECTIONS H250 M40 4.2.2 ESK4 / ESK4A current output The connecting terminals of the ESK4 / ESK4A have a pluggable design and can be removed in order to connect the cables. ESK4 / ESK4A connection 1 Current output of ESK4 / ESK4A 2 Power supply 14...30 VDC 3 Measuring signal 4...20 mA 4 External load, HART® communication Power supply M40 with galvanic isolation Wiring must be planned with great care when it comes to connecting other devices such as evaluation units or process control. Internal connections in these devices (e.g. GND with PE, mass loops) may lead to non-permitted voltage potentials which could negatively affect the function of the converter itself or that of a device connected to it. In such cases a protected extralow voltage (PELV) is recommended. 1 2 3 4 Terminal connection Converter isolator with galvanic isolation Power supply (refer to isolator information) Measuring signal 4...20 mA 5 External load, HART® communication 28 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 Power supply INFORMATION! The supply voltage has to be between 14 VDC and 30 VDC. This is based on the total resistance of the measuring loop. To calculate this, the resistance of each component in the measuring loop (not including the device) must be added together. The required supply voltage can be calculated using the formula below: Uext. = RL * 24 mA + 14 V with Uext. = minimum supply voltage RL = total measuring loop resistance INFORMATION! The power supply has to be able to supply a minimum of 30 mA. HART® communication When HART® communication is carried out with the ESK4, the analogue measured data transmission (4...20 mA) is not impaired in any way. Exception for multidrop operation. In multidrop operation a maximum of 15 devices with HART® function can be operated in parallel, whereby their current outputs are switched to inactive (I approx. 4 mA per device). 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 29 4 ELECTRICAL CONNECTIONS H250 M40 Load for HART® communication INFORMATION! For HART® communication a load of at least 230 Ω is required. The maximum load resistance is calculated as follows: DANGER! Use a twisted two-core cable to prevent electrical interference from impeding the DC output signal. In some cases a shielded cable may be necessary, e.g if noise levels higher than the NE 21 specification are anticipated. Configuration The ESK can be configured via HART® communication. DD (Device Description) for AMS and PDM as well as a DTM (Device Type Manager) for PACTwareTM are available for configuration. They can be downloaded free of charge from the website of the manufacturer. The current flow rate can be transmitted using the integrated HART® communication. A flow counter can be configured. Two limit values can be monitored. The limit values are assigned either to flow values or to the counter overflow. Self monitoring - Diagnostics During both start-up and operation, a wide variety of diagnostic functions are performed cyclically in the ESK4 / ESK4A in order to guarantee function reliability. When an error is detected, a failure signal (high) is activated (current > 21 mA, typically 22 mA) via the analogue output. In addition more detailed information can be requested via HART® (CMD#48). The failure signal is not activated for information and warnings. Diagnostic functions (Monitoring): • • • • • • • • Plausibility of FRAM data Plausibility of ROM data Working range of internal reference voltages Signal detection of the measuring range of the internal sensors Temperature compensation of the internal sensors Calibration based on the application Plausibility of counting value Plausibility of physical unit, system and selected unit For ESK4A (HART® 7) the diagnosis is reported in compliance with NE 107. 30 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 4.2.3 ESK4-T limit outputs Once the housing cover has been unscrewed, the scale can be removed. The connection terminals have a pluggable design and can be removed to connect the cables. 1 2 3 4 Binary output 1 ESK4 / ESK4A power supply / current output Binary output 2 Binary input The binary inputs/outputs are electrically isolated from each other and from the ESK4 / ESK4A current output. INFORMATION! The binary inputs/outputs can only be operated if the power supply is applied to ESK4 / ESK4A terminal 11+ and 12-. The binary inputs/outputs are inactive by default and must thus be activated prior to first use (for details refer to ESK4-T menu on page 46). Connection binary outputs In accordance with the desired signal transmission, select one of the following connection types for binary outputs B1 and B2: • NAMUR (DC interface acc. to EN 60947-5-6) • Transistor output (passive, Open Collector) Binary output B1 Terminal no. 1 2 Connection NAMUR + - Connection transistor output + 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com B2 3 BOC 4 5 + - + 6 BOC 31 4 ELECTRICAL CONNECTIONS 1 2 3 4 5 H250 M40 NAMUR terminal connection Isolated switching amplifier OC switch output terminal connection Power supply Uext. Load RL Value range for NAMUR NC contact NO contact Switching value reached < 1 mA > 3 mA Switching value not reached > 3 mA < 1 mA Value range applies only when connected to a switching amplifier with the following reference values: • Open-circuit voltage U0 = 8.2 VDC • Internal resistance Ri = 1 kΩ Value range for transistor output Signal voltages via load RL UL [V] lower limit upper limit lower limit upper limit 0 2 16 30 Signal currents Category 2 UH [V] IL [mA] IH [mA] lower limit upper limit lower limit upper limit 0 2 20 110 To ensure the value ranges, a load RL between 250 Ω and 1 kΩ is recommended for the passive transistor output with a nominal voltage of 24 VDC. If other loads are used, caution is advised as the range of values of the signal voltages then no longer corresponds to the range of values for the inputs of process control systems and controls (DIN IEC 946). CAUTION! The upper limit of the signal current must not be exceeded as this may damage the transistor output. 32 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 4.2.4 ESK4-T pulse output INFORMATION! The binary outputs can also be operated as pulse outputs. When using the binary outputs as a pulse output, two separate signal circuits are required. Each signal circuit requires its own power supply. The total resistance 4 must be adapted so that the total current Itot does not exceed 100 mA. Electrical connection of pulse output 1 2 3 4 5 6 Terminal for power supply - current output Terminal B2 Flow measurement 4...20 mA Pulse output load e.g. counter Power supply for ESK4 Power supply for pulse output The pulse output B2 is a passive "open collector" output which is electrically isolated from the current output and output B1. It can be operated as a low-resistance output or as a NAMUR output. Figure 4-2: Data for pulse output 1 fmax = 10 Hz 2 ton 3 toff The pulse width ton can be configured from 50...500 ms in the indicator menu. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 33 4 ELECTRICAL CONNECTIONS H250 M40 4.2.5 ESK4-T binary input The binary input can be used to control the internal flow counter (start/stop/reset). Value range for NAMUR Binary input B3 Terminal no. 7 8 Connection + - Binary input 1 Function active HI 2 Function active LO This binary input can be activated in the menu of the indicator and can be configured to ACTIVE HI or ACTIVE LO. If the input is set as ACTIVE LO, an interruption causes the counter to be reset. For further information on configuration of each function refer to ESK4-T menu on page 46. Value range Input voltage Terminal (7) (8) UL [V] UH [V] lower limit upper limit lower limit upper limit 0 2 16 30 The binary input has an internal resistance Ri of 20 kΩ. 34 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 4.2.6 ESK4-FF / ESK4-PA fieldbus communication 1 2 3 4 FF HSE Bus / Profibus DP Linking device / bus coupler FF H1 Bus / Profibus PA, 2-wire with shielding H250/M40/ESK4-FF / H250/M40/ESK4-PA ESK4-FF / ESK4-PA • • • • 2-wire, bus-supplied Polarity protected Bus voltage 9...32 VDC Nominal current 16 mA 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 35 4 ELECTRICAL CONNECTIONS H250 M40 4.2.7 Harting HAN 7D connection 1 Terminal pin assignment of HAN® 7D - View of plug connection K1/K2: NAMUR contacts R1/R2 Reed contacts ESK4/ESK4A 1 2 NAMUR MIN (-) 2 Reed MIN 2 2 NAMUR MIN (+) 3 4 1 Pin no. HAN® 7D Terminal no. NAMUR Reed - 1 1 2 Reed MIN - 2 3 3 NAMUR MAX (-) 3 Reed MAX - 4 4 3 NAMUR MAX (+) 3 Reed MAX - 5 6 5 - - 4 4...20mA (+) 11 6 - - 4 4...20mA (-) 12 7 - - - 8 - - - Combinations of K1 / K2 and ESK4 / ESK4A are possible. 1 Pin no. HAN® 7D ESK4-T Terminal no. 1 5 Binary output B1 open coll. (+) 1 2 5 Binary output B1 open coll. (-) 3 3 7 Binary output B2 open coll. (+) 4 4 7 Binary output B2 open coll. (-) 6 5 6 4...20mA (+) 11 6 6 4...20mA (-) 12 7 - 8 - INFORMATION! No Harting connection for module ESK4-FF/PA is provided and is only available on request. 36 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en ELECTRICAL CONNECTIONS 4 H250 M40 4.3 Grounding connections 1 Grounding connection in the indicator 2 Grounding connection outside DANGER! The grounding wire may not transfer any interference voltage. Do not use this grounding cable to ground any other electrical devices. 4.4 Ingress protection The measuring device meets all requirements of ingress protection IP66/68. DANGER! After all servicing and maintenance work on the measuring device, the specified protection class must be ensured again. Therefore it is essential to observe the following points. • Use only original gaskets. They must be clean and free of any damage. Defective gaskets must be replaced. • The electrical cables must be undamaged and must comply with regulations. • The cables must be laid with a loop 3 upstream of the measuring device to prevent water from getting into the housing. • The cable feedthroughs 2 must be tightened. • Close the unused cable feedthroughs using blanking plugs 1. 1 Use blanking plugs if no cable is routed through 2 Tighten cable feedthrough firmly 3 Lay the cable in a loop 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 37 5 START-UP H250 M40 5.1 Standard device CAUTION! When starting up the device, the following points must be observed: • Compare the actual operating pressure and the product temperature of the system with the • • • • • specifications on the nameplate (PS and TS). These specifications may not be exceeded. Make sure materials are compatible. Slowly open the shut-off valve. When measuring liquids ensure that the pipelines are carefully evacuated. When measuring gases, increase pressure slowly. Avoid float impact (e.g. caused by solenoid valves), as this is likely to damage the measuring unit or float. A minimum operating pressure (primary pressure) is necessary to operate the device: Medium Pressure loss : operating pressure Liquids 1:2 Gases without float damping 1:5 Gases with float damping 1:2 5.2 Indicator ESK4-T INFORMATION! The device is always preset for the user and his application. Start After the device is switched on, the display shows • "INITIALISING" • Firmwareversion IO-Modul The device first performs a self-test. Here, all of the parameters preset for the customer are analysed and checked for plausibility. The device then switches to measuring mode and indicates the current measured value. Operation INFORMATION! The device is low-maintenance Comply with the application limits with regard to temperature of the medium and ambient temperature. 38 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 6.1 ESK4 / ESK4A - Loop Check Mode The ESK4 / ESK4A is equipped with a loop check function, enabling a simple test of the entire 4…20 mA current loop. It is activated and operated using a microswitch 1. CAUTION! When activating the loop check mode, ensure that no alarms are unintentionally triggered in the downstream system components. • Press and hold the microswitch 1 for more than 6 seconds to activate the loop check mode 3. The current output jumps to constant 4 mA. • Change the current output from constant 4 mA to constant 20 mA as often as you like by briefly pressing it (less than 6 seconds) to check the function of the measuring circuit. • Exit loop check mode by holding down the microswitch (longer than 6 seconds). The current output jumps back to measuring mode 2. INFORMATION! If the microswitch has not been pressed for longer than 60 seconds, the ESK4 / ESK4A automatically returns to measuring mode 2. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 39 6 OPERATION H250 M40 6.2 Operating elements ESK4-T The device is operated with the cover on the front open, using the mechanical keys, keys or with the cover closed using a bar magnet. magnet CAUTION! The switching point of the magnetic sensors is directly at the height of the corresponding circle (see figure). Only touch the circle vertically and from the front using the bar magnet. Touching it from the side may cause an error in the measurement as the float position is recorded by the magnetic field sensors. Figure 6-1: Display and operating elements 1 Enter button (circuit for bar magnet) 2 Up button (circuit for bar magnet) 3 Right button (circuit for bar magnet) The mechanical keys and keys for the bar magnet have the same functionality. In this documentation the keys are represented as symbols to describe the operating functions: Key Symbol 1 Enter ^ 2 up ↑ 3 right → Table 6-1: ESK4-T operation keys 40 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 6.3 Basic principles of operation ESK4-T 6.3.1 Description of the operating keys → Switch from measuring mode to menu mode Switch to one menu level lower Open menu item and activate change mode Confirm query whether data should be accepted In change mode: Move the input cursor one position to the right. After the last digit the input cursor jumps back to the beginning. ↑ Change between the menu items within a menu level In measuring mode: Switch between measured values and error messages In change mode: Changing parameters or settings. Run through the available characters (including decimal point. ^ In measuring mode: Switch between measured value display and error messages / warnings Switch to one menu level higher Return to measuring mode with a query whether the data should be accepted Cancel the query, whether data should be accepted Table 6-2: Description of the operating keys 6.3.2 Navigation within the menu structure Navigate through the menu using the →, ↑ and ^ keys. Pressing the → key takes you one menu lower. Using the ↑ key takes you one menu item higher (e.g. from 1 to 2). Pressing the ^ key takes you one menu higher. If you are already at the lowest level (function level), the key takes you to the change mode, where you can set data and values. If you are at the first level (main menu), you can use the ^ key to exit the menu mode and return to the measuring mode. If settings were changed, the query whether they should be saved will appear. Confirm this query with the → key or cancel it with the ^ key. Measuring mode → ^ Main menu ↑ → ^ Submenu ↑ → ^ Function ↑ → ^ Edit →↑^ Table 6-3: Navigation in menu structure 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 41 6 OPERATION H250 M40 6.3.3 Change the settings in the menu Starting operation Operation is started using the → key. If an operation lock is set, the code (→ → → ^ ^ ^ ↑ ↑ ↑) must be entered. The code can be set in menu 3.13. The code shown here is set at the factory but not activated. If no key is activated within 5 seconds or an incorrect code is entered, a warning message is displayed and the indication returns to measuring mode. Exit operation Operation is exited by pressing the ^ key several times. If data have been changed: Save Yes → Changes are accepted. An update is carried out and the display returns to measuring mode. Save No ^ Changes are discarded and the display returns to measuring mode. CAUTION! Each time parameters or settings are changed, the measuring device carries out an internal plausibility check. If inplausible entries were made, a warning message is shown. If this warning is confirmed with the ^ key, the display returns to the respective menu item without saving the relevant change. A new entry can now be made. Example: Changing the flow unit from m3/h to l/h Display 42 Display Example: 7.2 m3/h 1x → Fct. 3.11.1 1 MEAS'D VALUE 1x → Fct. 1 OPERATION 1x → 10.0000 m3/h 2x ↑ Fct. 3 INSTALLATION 4x ↑ 10000 l/h 1x → Fct 3.1 1 LANGUAGE 10x ↑ Fct 3.11 11 FS&UNIT Confirm with → deny ^ 3x ^ www.krohne.com 7200 l/h 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 6.4 Overview of the units ESK4-T Volume units can either represent real operating volumes (no prefix before the unit) or standard volumes virtually converted to reference statuses. Prefix Volume definition None Operating volume flow e.g. m3/h or ft3/h N Volume flow at standard (norm.) conditions (0°C - 1.013 bara) acc. to DIN 1343 e.g. Nm3/h S Volume flow at standard (std.) conditions (15°C - 1.013 bara) acc. to ISO 13443 e.g. Sft3/h Measured variables Units Operating volume flow m3/s m3/min m3/h m3/d L/s L/min L/h - ft3/s ft3/min ft3/h ft3/d gal/s gal/min gal/h gal/d bbl/s bbl/min bbl/h bbl/d ImpGal/s ImpGal/min ImpGal/h ImpGal/d Standard (norm.) volume flow Nm3/s Nm3/min Nm3/h Nm3/d NL/s NL/min NL/h - Standard (std.) volume flow Sm3/s Sm3/min Sm3/h Sm3/d SL/s SL/min SL/h - Sft3/s Sft3/min Sft3/h Sft3/d g/s g/min g/h - kg/s kg/min kg/h kg/d - t/min t/h t/d lb/s lb/min lb/h lb/d - STon/min STon/h STon/d - LTon/h LTon/d l hl ft3 bbl bbl (liq) Mass flow Operating volume totalizer m ImpGal gallon Standard (norm.) volume totalizer Nm3 NL Standard (std.) volume totalizer Sft3 SL Sm3 Mass totalizer kg g t STon LTon °C °F Temperature 3 lb K In addition to the predefined units shown here, a user-defined unit can be activated in Menu 3.12 by entering a conversion factor and a unit designation as free text. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 43 6 OPERATION H250 M40 6.5 Error messages ESK4-T Error messages and warnings are indicated by one of the following symbols in the bottom left corner of the display. The ^ key switches from the measured value display to the display of current errors / warnings. The table below contains a description of possible error messages. Symbol NE107 Category Description Consequence F Failure No measured value available Output signal invalid Error current signal is output. S Out of specification Measurement available but increasing measurement uncertainty. Device must be checked. M Maintenance required Measurement still sufficiently accurate but maintenance required. C Function check Device is in test or linearization mode. The output signal temporarily does not correspond to the measurement. I Information No influence on the measurement, information only. Error message Description Category Remedy NOT LINEARIZED Linearization faulty or not activated = measuring error S NEW LINEARI. TABLE BAD Faulty or missing data in the linearization table = measuring error S1 Activate linearization or carry it out again (HART® communication and linearization software are required; the original calibration values must be known), or send the device back to the manufacturer for linearization. LINEARIZATIO UNDER CONFIG The device is in linearization mode = measuring error S Complete the linearization and activate it (HART® communication and linearization software are required), or send the device back to the manufacturer for linearization. UNIT SYSTEM CONFLICT The unit for the linearization flow is incompatible with the selected flow type (mass/volume) S Correct error, carry out linearization again if necessary (HART® communication and linearization software are required), or send the device back to the manufacturer for linearization. TOO FEW ENTRIES The linearization table has too few data points S Carry out linearization at at least 5 points (HART® communication and linearization software are required), or send the device back to the manufacturer for linearization. NOT MONOTONOUS The sequence of the linearization values is not strictly monotonic increasing S Check linearization and/or carry it out again (HART® communication and linearization software are required), or send the device back to the manufacturer for linearization. FIRST NOT 0 % The first flow value if the linearization table is not 0% LAST NOT 100 % The last flow value if the linearization table is not 100% 44 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 Error message Description Category Remedy NO ZERO CAL OF AO The current output zero point 4.00 mA is not calibrated = poss. measuring error in the process control system S Perform calibration using ammeter and menu 3.10 or using standard HART® tools/process control system and poss. external ammeter. Caution: during calibration, switch the measuring point to manual control. NO F.SC. CAL OF AO The current output 100% = 20.00 mA is not calibrated = poss. measuring error in the process control system S Perform calibration using ammeter and menu item 3.11 or using standard HART® tools and external ammeter if necessary. Caution: during calibration, switch the measuring point to manual control. NO TEMP. COMPENSATION The sensor temperature compensation of the device is faulty or was not carried out = possible measuring error S The device, together with an indication of the error, must be sent back to the manufacturer for checking. WRONG ELEC.REV. The ER revision of the ESK4 / ESK4A is not compatible with the addon module, or the ribbon cable connection is not connected properly. S Check that the ribbon cable fits properly. Check module compatibility (for details refer to Electronic revision on page 18). OUTPUT NOT LINEARIZED Linearization is not activated = measuring error S Activate linearization or carry it out again (HART® communication and linearization software are required; the original calibration values must be known), or send the device back to the manufacturer for linearization. COUNTER LOST Totalizer value was reset by error/overflow S1 Because the reset time is not known: Controlled reset of the counter using menu item 1.6.1 or using HART® tools/process control system. FRAM WRITE FAULT Internal communication error F Check whether the display is plugged in correctly and restart the device. If the error occurs again: send the device back to the manufacturer with an indication of the error. ROM/FLASH ERROR Memory error detected during self-test. F Restart device. If the error occurs again: send the device back to the manufacturer with an indication of the error. RESTART OF DEVICE A device restart has taken place I The device has been restarted using menu item 1.6.2 since the last time the error messages were reset. MULTIDROP MODE The HART® multidrop mode is activated. The current output is set to a fixed value of 4.5 mA. I The HART® multidrop mode is activated with selection of a polling address not equal to 0 using menu item 3.7. Polling address 0 reactivates the current output. CRYSTAL OSC FAULT Internal error in device F REF VOLTAGE FAULT Internal error in device The device must be sent back to the manufacturer with an indication of the error. SENSOR A FAULT Internal error in device SENSOR B FAULT Internal error in device MEMORY CORRUPTION Internal memory error, caused by a hardware or software problem F Restart the device; if the error occurs again the device must be sent back to the manufacturer with an indication of the error. AO FIXED The current output is set to a fixed value. I The current output is fixed and does not reflect the measured value. This is the case in multidrop mode, with current output test/calibration using the menu or HART®. AO SATURATED Current output saturated I The current output is saturated at >20.4 mA and is no longer linked to the measurement. 07/2016 - 4000640704 - MA H250-M40 R04 en F1 www.krohne.com 45 6 OPERATION H250 M40 Error message Description Category Remedy ERROR TIMEOUT Data not transferred, or transferred incorrectly from the ESK to the counter module F Confirm menu item "1.6.3 WRITE INFO I/O". WARNING TIMEOUT I 1 Category can be changed by user 6.6 ESK4-T menu 6.6.1 Factory settings Function Setting 1.1.1 OUTPUT B1 INACTIVE 1.2.1 OUTPUT B2 INACTIVE 1.3.1 PULSEWDTH 50ms 1.3.2 PULSE/UNIT 1 Pulse/Unit 1.4 DISPLAY MEAS’D VALUE 1.4.2 ROTATION 0° 1.5 TIME CONST. 1.0s 1.6.1 COUNTER NO 1.6.2 ERROR NO 1.6.3 RE-INIT I/O NO 3.1 LANGUAGE ENGLISH 3.2 FUNCTION B1 INACTIVE 3.3 CONTACT B1 NORM.OPEN 3.4 FUNCTION B2 INACTIVE 3.5 CONTACT B2 NORM.OPEN 3.6 FUNCTION B3 INACTIVE 3.7 MULTIDROP POLLING ADD: 00 3.8 4mA CALIBR. 4.000mA 3.9 20mA CALIBR. 20.000mA 3.10 ALARM CURR. ALARM HIGH 3.11 FS&UNIT Application specific 3.11.2 COUNTER Application specific 3.12 EDIT UNIT User defined unit / factor 3.13 L.FL.CUTOFF 4% ON; 6% OFF 3.14 DESCRIPTOR Free text 3.15 ENTRY CODE OFF 3.16 DEFAULT VAL. NO INFORMATION! The measuring device has been preset at the factory in accordance with the customer order. Therefore subsequent configuration via the menu is only necessary if the intended use of the device is changed. 46 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 6.6.2 Menu structure Main menu Submenu 1 Submenu 2 1 OPERATION 1.1 OUTPUT B1 1.1.1 INACTIVE, MEAS.VAL. B1, CNT. VAL. B1, PULSE WIDTH 1.1.2 HYST. B1, PULSE/UNIT 1.2 OUTPUT B2 1.2.1 INACTIVE, MEAS.VAL. B2, CNT. VAL. B2, PULSE WIDTH 1.2.2 HYST. B2, PULSE/UNIT 1.3 PULSE OUTP. 1.3.1 PULSE WIDTH 1.3.2 PULSE/UNIT 1.4 DISPLAY 1.4.1 MEAS'D VALUE, COUNTER, MV/COUNTER, MV&COUNTER, PERCENT 1.4.2 ROTATION 1.5 TIME CONST - 1.6 RESET 1.6.1 COUNTER 1.6.2 ERROR 1.6.3 WRITE INFO IO 2 TEST & INFO 2.1 4-20mA OUTP 2.1.1 NORMAL OP 2.1.2 4.0mA 2.1.3 5.6mA 2.1.4 7.2mA 2.1.5 8.8mA 2.1.6 10.4mA 2.1.7 12.0mA 2.1.8 13.6mA 2.1.9 15.2mA 2.1.10 16.8mA 2.1.11 18.4mA 2.1.12 20.0mA 2.1.13 21.6mA 2.2 ALARM CURR. ALARM HIGH, ALARM LOW 2.3 OUTPUT B1 2.3.1 NORMAL OP 2.3.2 OPEN 2.3.3 CLOSED 2.4 OUTPUT B2 2.4.1 NORMAL OP 2.4.2 OPEN 2.4.3 CLOSED 2.5 INPUT B3 ACTIVE HI, ACTIVE LO, ON, OFF 2.6 DEV. IDENT. 2.6.1 ELEC. REV. 2.6.2 SERIAL ESK4 2.6.3 PROD. ORDER 2.6.4 DEV. SN. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 47 6 OPERATION H250 M40 Main menu Submenu 1 Submenu 2 2 TEST & INFO 2.7 SOFT.VERSION 2.7.1 FW. ESK4 2.7.2 FW. ESK4 I/O 3 INSTALLATION 2.8 TAG NB. 8 characters 2.9 LONG TAG 32 characters 3.1 LANGUAGE 3.1.1 ENGLISH 3.1.2 DEUTSCH 3.1.3 FRANCAIS 3.1.4 ITALIANO 3.1.5 ESPANOL 3.1.6 CESKY 3.1.7 POLSKI 3.1.8 NEDERLANDS 3.1.9 DANSK 3.2 FUNCTION B1 INACTIVE, SWITCH POINT, COUNT. LIMIT, PULSE OUTP. 3.3 CONTACT B1 NORM.OPEN, NORM.CLOSED 3.4 FUNCTION B2 INACTIVE, SWITCH POINT, COUNT. LIMIT, PULSE OUTP. 3.5 CONTACT B2 NORM.OPEN, NORM.CLOSED 3.6 FUNCTION B3 INACTIVE, ACTIVE HI, ACTIVE LO, STARTH STOPL, STARTL STOPH 3.7 MULTIDROP POLLING ADD. 3.8 4mA CALIBR. 4.000mA 3.9 20mA CALIBR. 20.000mA 3.10 ALARM CURR. OFF, ALARM HIGH, ALARM LOW 3.11 FS&UNIT 3.11.1 MEAS'D VALUE 3.11.2 COUNTER 3.12 EDIT UNIT 3.12.1 MEAS'D VALUE 3.12.2 COUNTER 3.13 L.FL.CUTOFF 3.13.1 CONTROL ON, CONTROL OFF 3.13.2 ON VALUE 3.13.3 OFF VALUE 48 3.14 DESCRIPTOR Free text 3.15 ENTRY CODE OFF, ON 3.16 DEFAULT VAL. SET ALL www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 6.6.3 Menu description 1 OPERATION Selection / Input Explanation 1.1 OUTPUT B1 Output B1 is a binary switching output. In Fct. 3.2, one of the following functions can be selected for this output: INACTIVE, SWITCH POINT, COUNT. LIMIT, PULSE OUTP. One of the following functions can be selected as contact type in Fct. 3.3: NORM.OPEN 1 / NORM.CLOSED 2 1.1.1 INACTIVE - MEAS.VAL. B1 Switching point of flow value Value range: 0.0…full scale range The switching point is entered in flow units. If the current flow value exceeds this pre-determined switching point, output B1 changes its binary state 3. CNT. VAL. B1 Switching point of totaliser value Value range: 0.0…counter limit The switching point is entered in volume or mass units. If the the current counter value exceeds this pre-determined switching point, output B1 changes its binary state 3. There is no hysteresis setting for the switching point of the counter value. PULSE WIDTH Pulse weight (pulse/unit) The weight is only displayed here. In Fct. 1.1.2 a hysteresis can be specified additionally. A configuration takes place in Fct. 1.3.1 PULSE WIDTH, 1.3.2 PULSE/UNIT and 3.11.2 COUNTER. 1.1.2 HYST. B1 Hysteresis for the switching point of the flow value Value range: 0.0…switching point If the current flow value exceeds the pre-determined switching point from Fct. 1.1.1, output B1 changes its binary state 3. In order for output B1 to change its binary state back to the initial setting, the switching point made smaller by the hysteresis must be undershot 4. Example: In 1.1.1, a switching point of 200 L/h is set. The possible value range for the hysteresis is then 0.0…200 L/h. With a hysteresis value of 0, the switching point has no hysteresis (3=4). If a hysteresis value of 20 L/h is entered, output B1 changes its binary state to the initial setting, if it drops below 180 L/h 4. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 49 6 OPERATION H250 M40 Selection / Input Explanation 1.2 OUTPUT B2 Output B2 is a binary switching output. In Fct. 3.4, one of the following functions can be selected for this output: INACTIVE, SWITCH POINT, COUNT. LIMIT, PULSE OUTP. One of the following functions can be selected as contact type in Fct. 3.5: NORM.OPEN 1 / NORM.CLOSED 2 1.2.1 INACTIVE - MEAS.VAL. B2 Refer to MEAS.VAL. B1 In Fct. 1.2.2 a hysteresis can be specified additionally. CNT. VAL. B2 Refer to CNT. VAL. B1 PULSE WIDTH B2 Refer to PULSE WIDTH B1 A configuration takes place in Fct. 1.3.1 PULSE WIDTH, 1.3.2 PULSE/UNIT and 3.11.2 COUNTER. 1.2.2 HYST. B2 Refer to HYST. B1 1.3 PULSE OUTP. - 1.3.1 PULSE WIDTH 50ms Ti = 50 ms; fmax = 10 Hz max. pulses/h = 36000 100ms Ti = 100 ms; fmax = 5 Hz max. pulses/h = 18000 200ms Ti = 200 ms; fmax = 2.5 Hz max. pulses/h = 9000 500ms Ti = 500 ms; fmax = 1 Hz max. pulses/h = 3600 1.3.2 PULSE/UNIT 0.001...1000 Pulse per volume or mass unit of counter (setting in Fct. 3.11.2), which can be output via one of the binary outputs. The maximum frequency for the pulse output (refer to Fct 1.3.1) cannot be exceeded, even at maximum flow rate (full scale). Example: Final value Qmax = 1200 L/h; volume unit of counter = Litre; pulse width = 100ms; If the factor 1 is entered, 1 pulse/litre = 1200 pulses are generated in one hour at maximum flow rate. Number of max. permissible pulses: 50 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 1.4 DISPLAY Different measured values can be selected for permanent or alternating display. The reading on the display can be rotated. 1.4.1 MEAS’D VALUE Permanent display of flow in flow units COUNTER Permanent display of totalizer MEAS.VAL/CTN Alternating display of flow value in flow units and totalizer MEAS.VAL&CTN Simultaneous display of flow value and totalizer PERCENT Permanent display of flow value in percent 1.4.2 ROTATION 0° The reading is not rotated. 90° The reading on the display is rotated by 90°. 180° The reading on the display is rotated by 180°. 270° The reading on the display is rotated by 270°. 1.5 TIME CONST 0.0...20.0s Given in seconds The output variables (value of the current loop and indicated flow value) follow the current process by the value set here (in seconds) with a time delay. Note: If the current flow is polled via HART® communication, the transferred measured value is also played back with a delay. 1.6 RESET Local resetting of totalizer and acknowledgement of warnings. There is always a safety prompt ("YES / NO"), to avoid accidental resetting. Note: External resetting of the totalizer can be installed with the binary input B3. 1.6.1 COUNTER Confirming with "YES" resets the value of the totalizer to 0.0. 1.6.2 ERROR Confirming with "YES" acknowledges all existing warnings. Note: Confirming with "YES" acknowledges existing errors and warnings. 1.6.3 RE-INIT IO As a general rule, data is transferred from the counter module to the ESK4 and vice versa when the device starts. For safety, another data transmission can be performed by selecting this menu item and confirming with "YES". 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 51 6 OPERATION H250 M40 2 TEST & INFO Selection / Input Explanation 2.1 4-20mA OUTP Testing the current loop by setting various current values. Note: The test is not available in HART® multi-drop mode (refer to Fct. 3.7) Attention: During the test, the value of the current loop does not follow the current process. 2.1.1 NORMAL OP The value of the current loop follows the current process. 2.1.2 4.0mA The value of the current loop no longer follows the current process. It is set to the selected current value. 2.1.3 5.6mA 2.1.4 7.2mA 2.1.5 8.8mA 2.1.6 10.4mA 2.1.7 12.0mA 2.1.8 13.6mA 2.1.9 15.2mA 2.1.10 16.8mA 2.1.11 18.4mA 2.1.12 20.0mA 2.1.13 21.6mA 2.2 OUTPUT B1 <3.6 / >21 mA Testing the alarm current HIGH/LOW according to the settings in Fct. 3.10. 2.3 ALARM CURR. Testing the binary switching output B1 by changing its binary status. Attention: During the test, the binary status does not correspond to the current process. 2.3.1 NORMAL OP The binary status of the switching output corresponds to the current process. 2.3.2 OPEN The binary status of the switching output no longer corresponds to the current process. The selected status is tested. 2.3.3 CLOSED 2.4 OUTPUT B2 Refer to 2.2 OUTPUT B1 2.4.1 NORMAL OP 2.4.2 OPEN 2.4.3 CLOSED 2.5 INPUT B3 The current binary status of the binary input B3 is displayed. External switching of the voltage applied to input B3 activates a change of the displayed binary status. Note: A reaction to the switching of the voltage applied to input B3 only occurs if the function B3 is activated (refer to Fct. 3.6). 2.6 DEV. IDENT. Information for device identification 2.6.1 ELEC. REV. Electronic revision 2.6.2 SN ESK4 Serial number ESK4 2.6.3 PROD. ORDER Production order for the complete flowmeter 2.6.4 DEV. SN. Serial number for the complete flowmeter 2.7 SOFT.VERSION Information about software revision status 2.7.1 FW. ESK4 Software revision status for device insert ESK4-Basic 2.7.2 FW. ESK4 I/O Software revision status for optional add-on module ESK4-T 52 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 Selection / Input Explanation 2.8 TAG NB. 8 digits Measuring point identifier Alphanumerical characters. Up to eight digits are possible. 2.9 LONG TAG 32 digits Measuring point identifier Alphanumerical characters. Up to 32 digits are possible. 3 INSTALLATION Selection / Input Explanation 3.1 LANGUAGE Language selection for the displayed menu texts. 3.1.1 ENGLISH The menu texts are displayed in the selected language. 3.1.2 DEUTSCH 3.1.3 FRANCAIS 3.1.4 ITALIANO 3.1.5 ESPANOL 3.1.6 CESKY 3.1.7 POLSKI 3.1.8 NEDERLANDS 3.1.9 DANSK 3.2 FUNCTION B1 - INACTIVE The binary switching output B1 has no function. SWITCHING POINT The binary switching point B1 acts as a limit switch depending on the current flow value. Configuration of the switching point is in Fct. 1.1.1 MEAS.VAL. B1. COUNT. LIMIT The binary switching point B1 acts as a limit switch depending on the current counter value. Configuration of the switching point is in Fct. 1.1.1 MEAS.VAL. B1. PULSE OUTP. The binary switching point B1 acts as a pulse output depending on the current flow value. Pulses of a maximum of up to 10 Hz can be generated. The configuration is in Fct. 1.3.1 PULSE WIDTH and 1.3.2 PULSE/UNIT. Note: The configuration in Fct. 1.3.1 and Fct. 1.3.2 applies to both pulse outputs. If both B1 and B2 are configured as pulse outputs, both binary outputs behave in exactly the same way. 3.3 CONTACT B1 - NORM.OPEN The contact type of the binary switching output B1 is "normally open". NORM.CLOSED The contact type of the binary switching output B1 is "normally closed". 3.4 FUNCTION B2 - INACTIVE Refer to FUNCTION B1 SWITCHING POINT Refer to FUNCTION B1 Configuration of the switching point is in Fct. 1.2.1 MEAS.VAL. B2. COUNT. LIMIT Refer to FUNCTION B1 Configuration of the switching point is in Fct. 1.2.1 MEAS.VAL. B2. PULSE OUTP. Refer to FUNCTION B1 The configuration is in Fct. 1.3.1 PULSE WIDTH and 1.3.2 PULSE/UNIT. 3.5 CONTACT B2 - NORM.CLOSED Refer to CONTACT B1 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 53 6 OPERATION H250 M40 Selection / Input Explanation NORM.OPEN Refer to CONTACT B1 3.6 FUNCTION B3 - INACTIVE The binary switching input B3 has no function. ACTIVE HI The internal flow counter is reset to 0.0 if there is an H level at input B3 for at least 100 ms. ACTIVE LO The internal flow counter is reset to 0.0 if there is an L level at input B3 for at least 100 ms. STARTH STOPL The counter is started by creating an H level at input B3 and stopped by creating an L level at input B3. STARTL STOPH The counter is started by creating an L level at input B3 and stopped by creating an H level at input B3. 3.7 MULTIDROP 0…15 Polling address for HART® multi-drop mode When the address is 0, the HART® multi-drop mode is disabled. Attention: When the HART® multi-drop mode (Address 1…15) is activated, the current loop is inactive (fixed current value of "4.5mA") and no longer follows the current process. 3.8 4mA CALIBR. D/A calibration for lower range value (4mA) Note: This function is not available in HART® multi-drop mode. Attention: During calibration, the value of the current loop does not follow the current process. If an ampere meter detects in the 4...20 mA loop a deviation from the desired value of "4.000mA", the measured value must be entered. The correction value is accepted following the query to save and confirm with yes. 3.9 20mA CALIBR. D/A calibration for the full scale value (20 mA) Note: This function is not available in HART® multi-drop mode. Attention: During calibration, the value of the current loop does not follow the current process. If an ampere meter detects in the 4...20 mA loop a deviation from the desired value of "20.000mA", the measured value must be entered. The correction value is accepted following the query to save and confirm with yes. 3.10 ALARM CURR. - OFF Error indication via the current loop is deactivated. The current loop follows the current process. Note: This function is not available in HART® multi-drop mode. ALARM HIGH Error indication via the current loop is activated (failure signal "high" acc. to NE43). Note: This function is not available in HART® multi-drop mode. ALARM LOW Error indication via the current loop is activated (failure signal "low" acc. to NE43). Note: 1) This function is not available in HART® multi-drop mode. 2) This function is supported from ER 2.2.x. 3.11 END&UNIT By changing the unit, the respective final value is scaled accordingly. Depending on calibration, either units for volume or mass flow measurement are available for selection. 3.11.1 MEAS'D VALUE For units for volume flow or mass flow, refer to Overview of the units ESK4-T on page 43. 3.11.2 COUNTER For units for volume counter or mass counter and pulse output, refer to Overview of the units ESK4-T on page 43. 54 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en OPERATION 6 H250 M40 Selection / Input Explanation 3.12 EDIT UNIT User-defined unit with conversion to calibrated unit. 3.13 L.FL.CUTOFF L.FL.CUTOFF stands for low flow cutoff. To ensure a stable zero point of the current output, the current output can be set to a stable value of "4.00mA" 3 in a selectable range. 3.13.1 CONTROL OFF LFC function is not active. CONTROL ON L.FL.CUTOFF function is active. 3.13.2 LFC ON VAL Switch-on value 1: Value range 1…19% (of full scale range) The flow is greater than the switch-on value. The current output corresponds to this. If the flow rate falls, the current output follows until the switch-on value 1. If the flow value continues to fall, the current output is switched to "4.00mA" 3. Note: The switch-on value to be set must be smaller than the previously selected switch-off value. 3.13.3 OFF VALUE Switch-off value 2: Value range 2…20% (of full scale range) The flow rate is 0. The current output is "4.00mA" 3. If the flow rate increases, the current output remains at "4.00mA" until it has reached the switch-off value 2. Note: The switch-off value to be set must be greater than the previously selected switch-on value. 3.14 DESCRIPTOR 12 digits Free text input for header in LCD 3.15 ENTRY CODE Entry code for the local operating menu. The entry code is not active by default. 3.15.1 OFF The use of an entry code is not activated. 3.15.2 ON If "YES" is selected, the last code that was entered has to be typed in. Factory code: → → → ^ ^ ^ ↑ ↑ ↑ If, after confirmation with "YES", the → key is pressed additionally, then a new, individual, nine digits code can be typed in. The display shows the required key combination. 3.16 DEFAULT VAL. Resetting parameters to factory default. There is always a safety prompt ("YES / NO"), to avoid accidental resetting. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 55 7 SERVICE H250 M40 7.1 Maintenance Within the scope of routine maintenance of the system and pipelines, the flowmeter should also be inspected for signs of fouling, corrosion, mechanical wear and leaks, as well as damage to the measuring tube and the indicator. We advise that inspections are carried out at least once per year. The device must be removed from the pipeline before cleaning. CAUTION! Pressurised pipes have to be depressurised before removing the device. Empty the pipelines as completely as possible. In the case of devices used for measuring aggressive or hazardous media, appropriate safety precautions must be taken with regard to residual liquids in the measuring unit. New gaskets have to be used when re-installing the device in the pipeline. Avoid electrostatic charges when cleaning the surfaces (e.g. sight window)! 7.2 Replacement and retrofitting Some components of the variable area flowmeter can be retrofitted: • Float damping • • • • Indicator M40: Limit switch module K1 / K2 Current output 4..20 mA ESK4 / ESK4A Counter module with LCD and I/O ESK4-T Fieldbus interface ESK4-PA / FF 7.2.1 Replacing floats • • • • Remove the device from the pipeline. Take the upper snap ring out of the measuring unit. Take the upper float stop and float out of the measuring unit. Insert the new float into the centre hole of the lower float stop and push into the measuring unit along with the upper float stop. While doing this, the float's upper guide rod must be guided through the middle hole of the float stop. • Insert the snap ring into the measuring unit. • Fit the device back into the pipeline. CAUTION! Without a recalibration an additional measuring error is to be expected. 56 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SERVICE 7 H250 M40 7.2.2 Retrofitting float damping • • • • Take the upper snap ring 1 out of the measuring unit. Take the upper float stop 2 and float 5 out of the measuring unit. Fasten the retaining ring 3 into the lower slot of the float's guide rod. Slide ceramic sleeve 4 on to the float's guide rod and attach it to the top slot using the retaining ring 3. • Insert float into the lower float guide in the measuring unit. • Retrofit the supplied damping cylinder with the integrated float stop 2 into the measuring unit. • Insert upper snap ring 1. 1 2 3 4 5 Snap ring Float stop Locking ring Ceramic sleeve Float 7.2.3 Retrofitting limit switch • • • • Remove ESK4 / ESK4A add-on module (if available). Merge contact pointer 2 in the middle. Loosen the locking screw 1 on the contact pointer. Insert the contact module into slot 3 of the bracket until the semi-circle 1 on the contact board surrounds the pointer cylinder. The contact module connecting terminals feature a pluggable design and can be removed in order to connect the cables. WARNING! Do not damage the indicating element! 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 57 7 SERVICE H250 M40 7.2.4 Replacement - Retrofitting ESK4 / ESK4A CAUTION! When replacing or retrofitting an ESK4 / ESK4A, it is mandatory to indicate the serial number (SN) or sales order (SO) when ordering. This information can be found on the indicator nameplate. The ESK4 / ESK4A is factory calibrated, making it possible to replace it or retrofit it without recalibrating. • De-energise the ESK4 / ESK4A. • Lift and remove the ESK4 / ESK4A with a screwdriver. WARNING! Do not damage the indicating element! • The ESK4 / ESK4A plug-in tongues 1 are plugged in under the two bolts 2 on the base plate. • Slight pressure is used to press the ESK4 / ESK4A onto the spring pins 3 until it stops, firmly attaching the ESK4 / ESK4A. If a change in measuring range, product temperature, product, density, viscosity or pressure is desired, this can be done with the help of a variable area calculation program and with a HART® modem. However, each measuring unit is subject to its own physical limits, which the variable area calculation program correctly calculates, and may thus reject the desired change. If a change is performed using the program, the new data is also transmitted to the ESK4 / ESK4A: • • • • • • • • 58 Device identification Device address Serial number Measuring point identifier Digital measured value query in flow units, % and mA Test / setting functions Calibration 4.00 and 20.00 mA Set current output to any desired value www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SERVICE 7 H250 M40 7.2.5 Replacement - Retrofitting add-on module ESK4-T / PA / FF The add-on module for the ESK4 / ESK4A can be replaced or retrofitted on-site without removing the device from the process control. • ESK4-T (Display module with LCD and I/O) • ESK4-PA (Profibus PA interface) • ESK4-FF (Foundation Fieldbus interface) More detailed information can be found in the service manual included with each retrofit or replacement set. 7.3 Spare parts availability The manufacturer adheres to the basic principle that functionally adequate spare parts for each device or each important accessory part will be kept available for a period of 3 years after delivery of the last production run for the device. This regulation only applies to spare parts which are subject to wear and tear under normal operating conditions. 7.3.1 List of spare parts Spare part Order number DN15 Float CIV 15, 1.4404 X251041000 Float DIV 15, 1.4404 X251042000 Float TIV 15, 1.4404 X251043000 Float DIVT 15, 1.4404 X251044000 Float TIV 15, Aluminium X251043100 Float TIV 15, Titanium X251043200 Set float stop; standard (1 float stop, 1 span ring) X251050100 Set float stop; gas damping (ZrO2) X251050200 Set of float stop; gas damping (PEEK) X251050300 Damping bush (7x8) ZrO2 incl. 2 retaining rings X251053100 Damping bush (7x8) PEEK incl. 2x retaining rings X251053200 DN25 Float CIV 15, 1.4404 X252041000 Float DIV 25, 1.4404 X252042000 Float TIV 25, 1.4404 X252043000 Float DIVT 25, 1.4404 X252044000 Set float stop; standard (1 float stop, 1 span ring) X252050100 Set float stop; gas damping (ZrO2) X252050200 Set of float stop; gas damping (PEEK) X252050300 Damping bush (12x8) ZrO2 incl. 2x retaining ring X252053100 Damping bush (12x8) PEEK incl. 2x retaining ring X252053200 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 59 7 SERVICE H250 M40 Spare part Order number DN50 Float CIV 55, 1.4404 X253041000 Float DIV 55, 1.4404 X253042000 Float TIV55, 1.4404 X253043000 Float DIVT 55, 1.4404 X253044000 Set float stop; standard (1 float stop, 1 span ring) X253050100 Set float stop; gas damping (ZrO2) X253050200 Set of float stop; gas damping (PEEK) X253050300 Damping bush (14x10) ZrO2 incl. 2x retaining rings X253053100 Damping bush (14x10) PEEK incl. 2x retaining rings X253053200 DN80 Float CIV 85, 1.4404 X254041000 Float DIV 85, 1.4404 X254042000 Float TIV 85, 1.4404 X254043000 Float DIVT 85, 1.4404 X254044000 Set float stop; standard (1 float stop, 1 span ring) X254050100 Set float stop; gas damping (ZrO2) X254050200 Set of float stop; gas damping (PEEK) X254050300 Damping bush (18x14) ZrO2 incl. 2x retaining rings X254053100 Damping bush (18x14) PEEK incl. 2x retaining rings X254053200 DN100 Float CIV 105, 1.4404 X255041000 Float DIV 105, 1.4404 X255042000 Float DIVT 105, 1.4404 X255044000 Set float stop; standard (1 float stop, 1 span ring) only for bottom! X255050100 Set float stop; gas damping (ZrO2) X255050200 Set of float stop; gas damping (PEEK) X255050300 Damping bush (18x14) ZrO2 incl. 2x retaining rings X254053100 Damping bush (18x14) PEEK incl. 2x retaining rings X254053200 Indicator M40 Housing components Standard indicator housing M40 complete, no scale * X251110000 Standard indicator housing M40R complete, no scale* (stainless steel, non-coated) X251111000 Standard indicator housing M40S complete, no scale * (2-layer coating) X251112000 Standard cover M40 X251110100 Standard cover M40S (2-layer coating) X251110200 Standard cover M40R (stainless steel, non-coated) X251110400 Cover seal X251112100 M40 standard base plate X251120100 M40S standard base plate (2-layer coating) * X251120200 M40R standard base plate (stainless steel, non-coated) * X251120300 Standard = not pressure-tight 60 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SERVICE 7 H250 M40 Spare part Order number Housing components indicator M40 Retrofit kit HT extension X251021000 Module carrier (profile rail) X251121100 Set housing attachment parts X251121300 Pointer system, complete * X251122100 Magnetic brake for indicating element X251122200 * Accuracy loss without recalibration NAMUR 2-wire limit module Contact module K1 min I7S23,5-N X251135100 Contact module K1 max I7S23,5-N X251135200 Contact module K2 min / max I7S23,5-N X251135300 Contact module K1 min SC3,5 N0 X251133100 Contact module K1 max SC3,5 N0 X251133200 Contact module K2 min / max SC3,5 N0 X251133300 Contact module K2 min / min min - SJ3,5 S1N / SJ 3,5 SN X251133400 Contact module K2 max / max max - SJ3,5 S1N / SJ 3,5 SN X251133500 Contact module K1 min SJ3,5 SN X251133600 Contact module K1 max SJ3,5 SN X251133700 Contact module K1 min / max SJ3,5 SN X251133800 3-wire limit module, normally closed Contact module K1 min SB3,5 E2 - act.Low X251133900 Contact module K1 max SB3,5 E2 - act.Low X251134000 Contact module K1 min / max SB3,5 E2 - act.Low X251134100 3-wire limit module, normally open Contact module K1 min SB3,5 E2 - act.High X251134200 Contact module K1 max SB3,5 E2 - act.High X251134300 Contact module K1 min / max SB3,5 E2 - act.High X251134400 Electronic modules ESK4, ESK4-FF, ESK4-PA, ESK4-FF (serial number required) Cover for add-on modules X251121500 Connection cable ESK4 to add-on modules X251121600 Plugs (10 pcs) for ESK4 connection for bus modules X251132500 Replacement connector Replacement connector 11/12 for ESK4 X251121700 Replacement connector D/D+ for ESK4-FF or ESK4-PA X251121800 Replacement connectors 1/2/3, 4/5/6, 7/8 for ESK4-T X251121900 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 61 7 SERVICE H250 M40 Spare part Order number Replacement cable gland Single cable gland M20x1.5 black, plastic - for non-Ex / Ex-i X251150300 Single cable gland M20x1.5 blue, plastic - for non-Ex / Ex-i X251150100 Single cable gland M20x1.5 brass - for non-Ex / Ex-i / Ex-nA X251151000 Single cable gland M20x1.5 brass Ex-d/t - for Ex-d / Ex-t X251152000 Single plug M20x1.5 brass Ex-d/t - for Ex-d / Ex-t X251153000 Single cable gland M20x1.5 stainless steel Ex-d/t - for Ex-d / Ex-t X251154000 Single plug M20x1.5 stainless steel Ex-d/t - for Ex-d / Ex-t X251155000 INFORMATION! Other spare parts on request. 62 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en SERVICE 7 H250 M40 7.4 Availability of services The manufacturer offers a range of services to support the customer after expiration of the warranty. These include repair, maintenance, technical support and training. INFORMATION! For more precise information, please contact your local sales office. 7.5 Returning the device to the manufacturer 7.5.1 General information This device has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, it will rarely present any problems. CAUTION! Should you nevertheless need to return a device for inspection or repair, please pay strict attention to the following points: • Due to statutory regulations on environmental protection and safeguarding the health and safety of the personnel, the manufacturer may only handle, test and repair returned devices that have been in contact with products without risk to personnel and environment. • This means that the manufacturer can only service this device if it is accompanied by the following certificate (see next section) confirming that the device is safe to handle. CAUTION! If the device has been operated with toxic, caustic, radioactive, flammable or water-endangering products, you are kindly requested: • to check and ensure, if necessary by rinsing or neutralising, that all cavities are free from such dangerous substances, • to enclose a certificate with the device confirming that is safe to handle and stating the product used. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 63 7 SERVICE H250 M40 7.5.2 Form (for copying) to accompany a returned device CAUTION! To avoid any risk for our service personnel, this form has to be accessible from outside of the packaging with the returned device. Company: Address: Department: Name: Tel. no.: Fax no. and/or Email address: Manufacturer's order no. or serial no.: The device has been operated with the following medium: This medium is: radioactive water-hazardous toxic caustic flammable We checked that all cavities in the device are free from such substances. We have flushed out and neutralized all cavities in the device. We hereby confirm that there is no risk to persons or the environment through any residual media contained in the device when it is returned. Date: Signature: Stamp: 7.6 Disposal CAUTION! Disposal must be carried out in accordance with legislation applicable in your country. Separate collection of WEEE (Waste Electrical and Electronic Equipment) in the European Union: According to the directive 2012/19/EU, the monitoring and control instruments marked with the WEEE symbol and reaching their end-of-life must not be disposed of with other waste. waste The user must dispose of the WEEE to a designated collection point for the recycling of WEEE or send them back to our local organisation or authorised representative. 64 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 8.1 Functional principle The H250 flowmeter operates in accordance with the float measuring principle. The measuring unit consists of a metal cone in which a float can move freely up and down. The flow goes from bottom to top. The float changes position so that the lifting force acting on it F1 is in equilibrium with the form drag F2 and its weight F3: F3 = F1 + F2 1 Indication principle M40 magnetic coupling 2 Magnetic coupling sensors 1 For the indicator, the flow-dependent height of the float in the measuring unit is transmitted by means of a magnetic coupling and displayed on a scale. 2 For a built-in signal converter (ESK4 / ESK4A), the flow-dependent height of the float in the measuring unit is detected by the S1 and S2 magnetic field sensors and electronically processed. Operating principle of H250H and H250U Figure 8-1: Operating principle H250H and H250U 1 H250H - horizontal flow direction 2 H250U - flow direction from top to bottom The flowmeter operates in accordance with a modified float measuring principle. The guided float adjusts itself so that the flow force acting on it is in equilibrium with the opposing spring force. The flow-dependent position of the float in the measuring unit is displayed on a scale by means of a magnetic coupling. 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 65 8 TECHNICAL DATA H250 M40 8.2 Technical data INFORMATION! • The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local sales office. • Additional information (certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website (Downloadcenter). Measuring system Application range Flow measurement of liquids, gases and vapours Function / Measuring principle Variable area measuring principle Measured value Primary measured value Float position Secondary measured value Operating and standard volume flow Measuring accuracy Directive VDI/VDE 3513, sheet 2 (qG = 50%) H250 /RR /HC /F 1.6% H250/C (Ceramic, PTFE) H250H, H250U, H250 (100 : 1) 2.5% Precision (repeatability) H250 /RR /HC /F 0.25% H250H, H250U, H250 (100 : 1) 0.5% Operating conditions Temperature Max. operating temperature TS -196..+300°C / -321...+572°F Depending on the version (refer to nameplate) Pressure Max. operating pressure PS Depending on the version (refer to nameplate) Max. test pressure PT Depending on the version (refer to nameplate) Min. required operating pressure 2 times greater than pressure loss (refer to measuring ranges) Protection category M40, M40S, M40R IP66/68 acc. to EN 60529, NEMA 4/4X/6 acc. to NEMA 250 M40R IP69K acc. to DIN 40050-9 Float damping during gas measurement recommended: DN15...25 / ½"...1" Operating pressure <0.3 barg / 4.4 psig DN50...100 / 2"...4" Operating pressure <0.2 barg / 2.9 psig Installation conditions acc. to VDI/VDE 3513, sheet 3 66 Inlet section ≥ 5 x DN Outlet section ≥ 3 x DN www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 Materials Device Flange Measuring tube Float Float guide H250/RR Stainless steel CrNi 1.4404 / 316L H250/HC Hastelloy® C4 (2.4610) solid or plated H250/F - Food CrNi steel 1.4435 CrNi-steel 1.4435 / 1.4404 H250/C Ceramic/PTFE 1 CrNi steel 1.4571 with TFM/PTFE 2 PTFE or Al2O3 with FFKM gasket Ring orifice Hastelloy® C4 Al2O3 and PTFE Al2O3 1 DN100/4" only PTFE 2 TFM/PTFE liner (electrically non-conductive), conductive PTFE on request Other options on request: • Special materials: e.g. SMO 254/6Mo/1.4547, Titan Grade 2, Hastelloy® C276/2.4819, Monel®/2.4360, Inconel®/2.4856 a.o. • Float damping: ceramic or PEEK • Standard gasket for devices with female thread as insert: O-ring FPM / FKM, others optional e.g. FFKM, EPDM M40 Aluminium, single-layer powder coating (polyester) M40S Aluminium, two-layer powder coating (epoxy / polyester) M40R Stainless steel without coating 1.4408 / CF8M Offshore Wet coating on request Temperatures For devices to be used in hazardous areas, special temperature ranges apply. These can be found in the Ex supplementary instructions. Temperatures H250/M40 - mechanical indicator without auxiliary power Material Product temperature Ambient temperature [°C] [°F] [°C] [°F] -196...+300 -321...+572 -40...+120 -40…+248 H250/RR screw fitting FPM/FKM -20...+200 -4...+392 -20…+120 -4…+248 H250/HC Hastelloy® -196...+300 -321...+572 -40...+120 -40…+248 H250/C PTFE -196...+70 -321...+158 -40...+70 -40…+158 H250/C Ceramic PTFE -196...+150 -321...+302 -40...+70 -40…+158 H250/C Ceramic TFM / Ceramic -196...+250 -321...+482 -40...+120 -40…+248 H250 H/U Spring material stainless steel 1.4301 -40...+100 -40…+212 -40…+120 -40…+248 -40...+200 -40...+392 -40…+120 -40…+248 Float H250/RR Liner Stainless steel ® Spring material Hastelloy 2.4610 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 67 8 TECHNICAL DATA H250 M40 Ambient temperatures Tamb with electrical components Version [°C] [°F] ESK4, ESK4A, ESK4-FF, ESK4-PA 1 -40...+70 -40...+158 Limit switches SJ3,5-SN / I7S23,5-N / Reed SPST -40...+70 -40...+158 Limit switches SC3,5-N0 / SJ3,5-S1N / SB3,5-E2 -25...+70 -13...+158 1 Display contrast out of the temperature range 0...+60°C / +32...+140°F decreasing. Maximum product temperatures H250/M40 - with electrical components [°C] Tamb < +40°C Tamb < +60°C 1 EN ASME Version with Standard HT Standard HT DN15, DN25 ½", 1" ESK4 / ESK4A, -FF, -PA +200 +300 +180 +300 ESK4-T +200 +300 +140 +290 NAMUR limit switch +200 +300 +200 +300 3-wire limit switch +200 +300 +130 +295 ESK4 / ESK4A, -FF, -PA +200 +300 +165 +300 ESK4-T +200 +300 +140 +290 NAMUR limit switch +200 +300 +200 +300 3-wire limit switch +200 +300 +120 +195 ESK4 / ESK4A, -FF, -PA +200 +300 +150 +250 ESK4-T +200 +300 +130 +270 NAMUR limit switch +200 +300 +200 +300 3-wire limit switch +190 +300 +110 +160 DN50 DN80, DN100 2" 3", 4" Maximum product temperatures H250/M40 - with electrical components [°F] Tamb < +104 °F Tamb < +140 °F 1 EN ASME Version with Standard HT Standard HT DN15, DN25 ½", 1" ESK4 / ESK4A, -FF, -PA 392 572 356 572 ESK4-T 392 572 284 554 NAMUR limit switch 392 572 392 572 3-wire limit switch 392 572 266 563 ESK4 / ESK4A, -FF, -PA 392 572 165 572 ESK4-T 392 572 284 554 NAMUR limit switch 392 572 392 572 3-wire limit switch 392 572 248 383 ESK4 / ESK4A, -FF, -PA 392 572 302 482 ESK4-T 392 572 266 518 NAMUR limit switch 392 572 392 572 3-wire limit switch 374 572 230 320 DN50 DN80, DN100 2" 3", 4" 1 if there are no heat insulation measures, a heat-resistant cable is necessary (continuous operating temperature of the cable to be used: +100°C / 212°F) 68 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 Abbreviation HT High-temperature version ESK4 / ESK4A 2-wire current output 4…20 mA with HART 5® / HART 7® ESK4-T ESK4 with LCD, binary status outputs, digital counter and pulse output ESK4-FF FOUNDATION FIELDBUS interface ESK4-PA PROFIBUS PA interface Cable glands Material Cable diameter [mm] [Inch] M20x1.5 Standard PA 8...13 0.315...0.512 M20x1.5 Nickel-plated brass 10...14 0.394...0.552 M20x1.5 Stainless steel 10...14 0.394...0.552 Limit switches K1/K2 Terminal connection 2.5 mm2 Limit switches I7S23,5-N SC3,5-N0 SJ3,5-SN 1 SJ3,5-S1N 1 SB3,5-E2 Reed NAMUR (IEC 60947-5-6) Yes Yes Yes No No Connection type 2-wire 2-wire 2-wire 3-wire 2-wire Switching element function NC NC NO PNP NO NC SPST Nominal voltage U0 8.2 VDC 8.2 VDC 8.2 VDC 10...30 VDC max. 32 VDC Pointer vane not detected ≥ 3 mA ≥ 3 mA ≤ 1 mA ≤ 0.3 VDC U0 Pointer vane detected ≤ 1 mA ≤ 1 mA ≥ 3 mA UB -3 VDC 0 VDC Continuous current - - - Max. 100 mA Max. 100 mA No load current I0 - - - ≤ 15 mA - Switching cycles - - - - 100000 2 1 safety oriented 2 no inductances Current output ESK4 / ESK4A Terminal connection 2.5 mm2 Power supply 14...30 VDC (12...30 VDC without ESK4-T) Min. power supply for HART® 20 VDC at 250 Ω load Measuring signal 4.00...20.00 mA = 0...100% flow value in 2-wire technology Power supply influence <0.1% External resistance dependency <0.1% Temperature influence <5 µA/K Max. external resistance / load 650 Ω at 30 VDC Min. load for HART® 250 Ω 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 69 8 TECHNICAL DATA H250 M40 ESK4 HART® configuration Manufacturer name (code) ® Model name / HART revision KROHNE Messtechnik (0x45 = 69) ESK4 (214 = 0xD6) / HART 5.9 ESK4A (17854 = 0x45BE) / HART 7.4 Physical layer FSK ESK4 / ESK4A process variable Values [%] from full scale range Signal output [mA] Over range +102.5 (±1%) 20.24...20.56 Device error identification > 106.25 >21.00 Max. current consumption 131.25 25 Multidrop operation 4.5 ESK4-FF Physical layer IEC 61158-2 and FISCO model Communication standard H1 FOUNDATION Fieldbus protocol ITK version 5.2 Power supply Bus supply Nominal current 16 mA Error current 23 mA Boot-up current after 10 ms < Nominal current For more details refer to the supplementary instructions "H250 M40 Foundation Fieldbus". ESK4-PA Physical layer IEC 61158-2 and FISCO model Communication standard Profibus PA profile 3.02 PNO ID 4531 HEX Power supply Bus supply Nominal current 16 mA Error current 23 mA Boot-up current after 10 ms < Nominal current For more details refer to the supplementary instructions "H250 M40 Profibus PA". 70 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 ESK4-T with LCD, binary inputs and outputs and digital counter Binary output Two binary outputs Galvanically isolated; passive Mode Switching output NAMUR or transistor (OC) Configurable as switch contact or pulse output NC / NO or max. 10 pulses/s NAMUR switch output Power supply 8.2 VDC Signal current > 3 mA switching value not reached; < 1 mA switching value reached Switching output transistor (Open Collector) Power supply Nominal 24 VDC, maximal 30 VDC Pmax 500 mW Continuous current Max. 100 mA No load current I0 ≤ 2 mA Pulse output Ton Configurable from 50...500 ms Toff Depending on flow rate Pulse weight Configurable in flow units e.g. 5 pulses/m3 Binary input Input Galvanically isolated Mode Reset counters or Start / Stop Configurable as active HI / active LO H signal 16...30 VDC Internal resistance Ri Typ. 20 kΩ Ton (active) ≥ 500 ms LC display Technology Passive graphic LCD Display Measurement with units and/or counter reading with units. Counter reading max. 11-digit with power failure proof storage. Binary flags for limit value status. 0...100% bargraph for measurement. NE 107 diagnostic status symbols. Plain text menu for configuration. Configuration Local plain text menu navigation via microswitch or bar magnet or using DD/DTM software 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 71 8 TECHNICAL DATA H250 M40 Approvals 72 Standard Display Marking ATEX / IECEx M40 mechanical II2GD IIC II3GD IIC M40 electrical II2G Ex ia IIC T6 Gb II2G Ex d IIC T6 Gb II3G Ex nA IIC T6 Gc II2D Ex t IIIC T70°C Db II2D Ex ia IIIC T85°C Db FM (USA) NEC500 FM (Canada) NEC505 M40 electrical IS Class I Div 1 XP Class I Div 1 NI Class I Div 2 DIP Class II / III Div 1 NEPSI M40 electrical Ex ia, Ex d, Ex nA, Ex t CCOE/PESO M40 electrical Ex ia, Ex d EAC/GOST M40 electrical Ex ia, Ex d INMETRO M40 electrical Ex ia, Ex d, Ex nA, Ex t KGS M40 electrical Ex ia, Ex d, Ex nA, Ex t www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 8.3 Dimensions and weights Dimensions H250/M40 Front view Side view with heating a b [mm] H250/RR Flange H250/F Clamp connection ["] 141 [mm] 5.56 H250/RR from 2" 600 lb ISO 228 / ASME B1.20.1 / SMS EN ASME c1 [mm] [mm] d ["] 9.85 300 11.82 ["] 150 [mm] [mm] 5.91 Øf ["] h [mm] 250 e2 ["] High-temperature 150 g ["] [mm] ["] 5.91 j ["] [mm] ["] DN15 ½" 94 3.70 114 4.49 20 0.80 97 3.82 197 7.76 DN25 1" 94 3.70 127 5.00 32 1.28 109 4.27 209 8.23 DN50 2" 107 4.22 141 5.55 65 2.57 125 4.90 222 8.74 DN80 3" 107 4.22 157 6.18 89 3.51 143 5.61 238 9.37 DN100 4" 107 4.22 167 6.57 114 4.50 150 5.91 248 9.76 1 without cable gland; 2 Ex d, Ex t, Ex nA +10 mm / 0.39" ISO 228 / ASME B1.20.1 Female thread screwed ISO 228 / ASME B1.20.1 Female thread welded H250/F 1 Clamp connection H250/F screw connection DIN 11851 1 Stainless steel 1.4435 - EHEDG tested - wetted surfaces Ra ≤ 0.8 / 0.6 µm 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 73 8 TECHNICAL DATA H250 M40 Weights H250 Heating Nominal size EN 1092-1 with flange connection with Ermeto connection EN ASME [kg] [lb] [kg] [lb] [kg] [lb] DN15 ½" DN25 1" 3.5 7.7 5.6 12.6 3.9 8.6 5 11 7.5 16.5 5.8 12.8 DN50 2" 8.2 18.1 11.2 24.7 9.5 21 DN80 3" 12.2 26.9 14.8 32.6 13.1 28.9 DN100 4" 14 30.9 17.4 38.4 15.7 34.6 H250/C [Ceramic / PTFE] Screw connection Nominal size EN 1092-1 ASME 150 lb ASME 300 lb DIN 11864-1 EN ASME [kg] [lb] [kg] [lb] [kg] [lb] [kg] [lb] DN15 ½“ 3.5 7.7 3.2 7.1 3.5 7.7 2 4.4 DN25 1“ 5 11 5.2 11.5 6.8 15 3.5 7.7 DN50 2“ 10 22.1 10 22.1 11 24.3 5 11 DN80 3“ 13 28.7 13 28.7 15 33.1 7.6 16.8 DN100 4“ 15 33.1 16 35.3 17 37.5 10.3 22.7 Process connections Standard Flanges (H250/RR /HC /C) Conn. dim. Pressure rating EN 1092-1 DN15...150 PN16...250 ASME B16.5 ½...6" 150...2500 lb JIS B2220 15…100 10...20K DIN 32676 DN15...100 10...16 bar ISO 2852 Size 25...139.7 10...16 bar DIN 11851 DN15...100 25...40 bar SMS 1146 1...4" 6 barg / 88.2 psig ISO 228 G½...G2" ≥ 50 barg / 735 psig ASME B1.20.1 ½…2" NPT Female thread (H250/RR /HC) with insert, FPM gasket and union nut ISO 228 G½…2" ASME B1.20.1 ½…2" NPT Thread connection aseptic (H250/F) DIN 11864-1 DN15…50 PN40 DN80…100 PN16 DN15…50 PN40 DN80…DN100 PN16 EN 1092-1 DN15 PN40 ASME B16.5 ½" 150 lb / RF - E12 PN40 Clamp connections (H250/RR /F) Screw connections (H250/RR /HC /F) Female thread welded (H250/RR /HC) Flange aseptic (H250/F) DIN 11864-2 ≤ 50 barg / 735 psig Measuring device (H250/RR /HC) with heating: Heating with flange connection Heating pipe connection for Ermeto Higher pressure ratings and other connections on request 74 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 Bolts and tightening torques For measuring devices with PTFE liner or ceramic liner and PTFE raised face, tighten the flange threads with the following torques: Nominal sizes EN Stud bolts Nominal size acc. to EN 1092-1 Tightening torques Quantity x size [Nm] [lb-ft] DN15 PN40 1 4x M12 9.8 7.1 DN25 PN40 1 4x M12 21 15 DN50 PN40 1 4x M16 57 41 DN80 PN16 1 8x M16 47 34 DN100 PN16 1 8x M16 67 48 1 standard connections; other connections on request Nominal size ASME Stud bolts Nominal size acc. to ASME B16.5 Tightening torques Quantity x size 150 lb [Nm] [lb-ft] 300 lb ½" 150 lb / 300 lb 1 4x ½" 4x ½" 5.2 3.8 1" 150 lb / 300 lb 1 4x ½" 4x 5/8" 10 7.2 2" 150 lb / 300 lb 1 4x 5/8" 8x 5/8" 41 30 3" 150 lb / 300 lb 1 4x 5/8" 8x ¾" 70 51 4" 150 lb / 300 lb 1 8x 5/8" 8x ¾" 50 36 1 standard connections; other connections on request Pressure tightness (vacuum) H250/C Max. process temperature +70°C / +158°F +150°C / +302°F +250°C / +482°F Min. operating pressure Nominal size Float Liner [mbara] [psia] [mbara] [psia] [mbara] [psia] DN15...100 PTFE PTFE 100 1.45 - - - - DN15...80 Ceramic PTFE 100 1.45 250 3.63 - - DN15...80 Ceramic TFM / Ceramic 100 1.45 100 1.45 100 1.45 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 75 8 TECHNICAL DATA H250 M40 8.4 Measuring ranges H250/RR - Stainless Steel, H250/HC - Hastelloy® Measuring span: 10 : 1 Flow values: Values = 100% Water: +20°C / +68°F Water Float Nominal size DN15, ½" DN25, 1" DN50, 2" DN80, 3" DN100, 4" TIV Cone CIV Air: +20°C / +68°F, 1.013 bara / 14.7 psia Air DIV TIV Alu. [l/h] Max. pressure loss TIV DIV TIV Alu. TIV CIV DIV [mbar] [Nm3/h] K 15.1 18 25 - 0.42 0.65 - 12 21 26 - K 15.2 30 40 - 0.7 1 - 12 21 26 - K 15.3 55 63 - 1 1.5 - 12 21 26 - K 15.4 80 100 - 1.7 2.2 - 12 21 26 - K 15.5 120 160 - 2.5 3.6 - 12 21 26 - K 15.6 200 250 - 4.2 5.5 - 12 21 26 - K 15.7 350 400 700 6.7 10 18 1 12 21 28 38 K 15.8 500 630 1000 10 14 28 1 13 22 32 50 K 15.8 - - 1600 2 - - 50 2 - - - 85 K 25.1 480 630 1000 9.5 14 - 11 24 32 72 K 25.2 820 1000 1600 15 23 - 11 24 33 74 K 25.3 1200 1600 2500 22 35 - 11 25 34 75 K 25.4 1700 2500 4000 37 50 110 1 12 26 38 78 K 25.5 3200 4000 6300 62 95 180 1 13 30 45 103 3 K 55.1 2700 6300 8400 58 80 230 1 8 13 74 60 K 55.2 3600 10000 14000 77 110 350 1 8 13 77 69 K 55.3 5100 16000 25000 110 150 700 1 9 13 84 104 K 85.1 12000 25000 37000 245 350 1000 1 8 16 68 95 K 85.2 16000 40000 64000 280 400 1800 1 9 16 89 125 K105.1 19000 63000 100 000 - 550 2800 1 - - 120 220 1 P >0.5 bar 2 with TR float 3 300 mbar with damping (gas measurement) INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to Nl/h or Nm3/h: Volume flow at standard (norm.) conditions 0°C - 1.013 bara (DIN 1343) 76 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 H250/RR - stainless steel, H250/HC - Hastelloy® Measuring span: 10 : 1 Flow values: Values = 100% Water: +20°C / +68°F Water Float TIV CIV Air: +20°C / +68°F, 1.013 bara / 14.7 psia Air DIV TIV Alu. DIV TIV Alu. TIV DIV Cone DN15, ½" K 15.1 4.76 6.60 - 0.26 0.40 - 0.18 0.31 0.38 - K 15.2 7.93 10.6 - 0.43 0.62 - 0.18 0.31 0.38 - K 15.3 14.5 16.6 - 0.62 0.93 - 0.18 0.31 0.38 - K 15.4 21.1 26.4 - 1.05 1.36 - 0.18 0.31 0.38 - K 15.5 31.7 42.3 - 1.55 2.23 - 0.18 0.31 0.38 - K 15.6 52.8 66.0 - 2.60 3.41 - 0.18 0.31 0.38 - K 15.7 92.5 106 185 4.15 6.20 11.2 1 0.18 0.31 0.41 0.56 K 15.8 132 166 264 6.20 8.68 17.4 1 0.19 0.32 0.47 0.74 K 15.8 - - 423 2 - - 31.0 2 - - - 1.25 K 25.1 127 166 264 5.89 8.68 - 0.16 0.35 0.47 1.06 K 25.2 217 264 423 9.30 14.3 - 0.16 0.35 0.49 1.09 K 25.3 317 423 660 13.6 21.7 - 0.16 0.37 0.50 1.10 K 25.4 449 660 1057 22.9 31.0 68.2 1 0.18 0.38 0.56 1.15 K 25.5 845 1057 1664 38.4 58.9 111 1 0.19 0.44 0.66 1.51 3 K 55.1 713 1664 2219 36.0 49.6 143 1 0.12 0.19 1.09 0.88 K 55.2 951 2642 3698 47.7 68.2 217 1 0.12 0.19 1.13 1.01 K 55.3 1347 4227 6604 68.2 93.0 434 1 0.13 0.19 1.23 1.53 K 85.1 3170 6604 9774 152 217 620 1 0.12 0.24 1.00 1.40 K 85.2 4227 10567 16907 174 248 1116 1 0.13 0.24 1.31 1.84 K105.1 5019 16643 26418 - 341 1736 1 - 1.76 3.23 DN50, 2" DN80, 3" DN100, 4" [SCFM] CIV Nominal size DN25, 1" [GPH] TIV Max. pressure loss [psig] 1 P >7.4 psig 2 with TR float 3 4.4 psig with damping (gas measurement) INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to SCFM or SCFH: Volume flow at standard (std.) conditions 15°C - 1.013 bara (ISO 13443) 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 77 8 TECHNICAL DATA H250 M40 H250/C - Ceramic/PTFE Measuring span: 10 : 1 Flow values: Values = 100% Water: +20°C / +68°F Air: +20°C / +68°F, 1.013 bara / 14.7 psia Flow Max. pressure loss Water Liner / Float Nominal size DN15, ½" DN25, 1" DN50, 2" DN80, 3" DN100, 4" Cone PTFE Air Ceramic [l/h] PTFE Water Ceramic PTFE Air Ceramic PTFE Ceramic [mbar] [Nm3/h] E 17.2 25 30 0.7 - 65 62 65 62 E 17.3 40 50 1.1 1.8 66 64 66 64 E 17.4 63 70 1.8 2.4 66 66 66 66 E 17.5 100 130 2.8 4 68 68 68 68 E 17.6 160 200 4.8 6.5 72 70 72 70 E 17.7 250 250 7 9 86 72 86 72 E 17.8 400 - 10 - 111 - 111 - E 27.1 630 500 16 18 70 55 70 55 E 27.2 1000 700 30 22 80 60 80 60 E 27.3 1600 1100 45 30 108 70 108 70 E 27.4 2500 1600 70 50 158 82 158 82 E 27.5 4000 1 2500 120 75 290 100 194 100 E 57.1 4000 4500 110 140 81 70 81 70 E 57.2 6300 6300 180 200 110 80 110 80 E 57.3 10000 11000 250 350 170 110 170 110 E 57.4 16000 1 - - - 284 - - - E 87.1 16000 16000 - - 81 70 - - E 87.2 25000 25000 - - 95 85 - - E 87.3 40000 1 - - - 243 - - - E 107.1 40000 - - - 100 - - - E 107.2 60000 1 - - - 225 - - - 1 special float INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to Nl/h or Nm3/h: Volume flow at standard (norm.) conditions 0°C - 1.013 bara (DIN 1343) 78 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 H250/C - Ceramic/PTFE Measuring span: 10 : 1 Flow values: Values = 100% Water: +20°C / +68°F Air: +20°C / +68°F, 1.013 bara / 14.7 psia Flow Max. pressure loss Water Liner / Float Nominal size DN15, ½" DN25, 1" DN50, 2" DN80, 3" DN100, 4" PTFE Cone Air Ceramic [GPH] PTFE Water Ceramic PTFE [SCFM] Air Ceramic PTFE Ceramic [psig] E 17.2 6.60 7.93 0.43 - 0.94 0.90 0.94 0.90 E 17.3 10.6 13.2 0.68 1.12 0.96 0.93 0.96 0.93 E 17.4 16.6 18.5 1.12 1.49 0.96 0.96 0.96 0.96 E 17.5 26.4 34.3 1.74 2.48 0.99 0.99 0.99 0.99 E 17.6 42.3 52.8 2.98 4.03 1.04 1.02 1.02 1.02 E 17.7 66.0 66.0 4.34 5.58 1.25 1.04 1.25 1.04 E 17.8 106 - 6.2 - 1.61 - 1.61 - E 27.1 166 132 9.92 11.2 1.02 0.80 1.02 0.80 E 27.2 264 185 18.6 13.6 1.16 0.87 1.16 0.87 E 27.3 423 291 27.9 18.6 1.57 1.02 1.57 1.02 E 27.4 660 423 43.4 31.0 2.29 1.19 2.29 1.19 E 27.5 1056 1 660 74.4 46.5 4.21 1.45 2.81 1.45 E 57.1 1057 1189 68.2 86.8 1.18 1.02 1.18 1.02 E 57.2 1664 1664 111.6 124 1.60 1.16 1.60 1.16 E 57.3 2642 2906 155 217 2.47 1.60 2.47 1.60 E 57.4 4226 1 - - - 4.12 - - - E 87.1 4227 4227 - - 1.18 1.02 - - E 87.2 6604 6604 - - 1.38 1.23 - E 87.3 10567 1 - - - 3.55 - - E 107.1 10567 - - - 1.45 - - E 107.2 15850 1 - - - 3.29 - - 1 special float INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to SCFM or SCFH: Volume flow at standard (std.) conditions 15°C - 1.013 bara (ISO 13443) 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 79 8 TECHNICAL DATA H250 M40 H250H - Horizontal installation position Measuring span: 10 : 1 Flow values: Values = 100% EN DN15 DN25 DN50 DN80 DN100 ASME Water: +20°C / +68°F Cone ½ 1" 2" 3" 4" Air: +20°C / +68°F, 1.013 bara / 14.7 psia Water [l/h] Pressure loss [mbar] Air [Nm3/h] K 15.1 70 1.8 195 K 15.2 120 3 204 K 15.3 180 4.5 195 K 15.4 280 7.5 225 K 15.5 450 12 250 K 15.6 700 18 325 K 15.7 1200 30 590 K 15.8 1600 40 950 K 15.8 2400 60 1600 K 25.1 1300 35 122 K 25.2 2000 50 105 K 25.3 3000 80 116 K 25.4 5000 130 145 K 25.5 8500 220 217 K 25.5 10000 260 336 K 55.1 10000 260 240 K 55.2 16000 420 230 K 55.3 22000 580 220 K 55.3 34000 900 420 K 85.1 25000 650 130 K 85.2 35000 950 130 K 85.2 60000 1600 290 K 105.1 80000 2200 250 K 105.1 120000 3200 340 INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to Nl/h or Nm3/h: Volume flow at standard (norm.) conditions 0°C - 1.013 bara (DIN 1343) 80 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 H250H - Horizontal installation position Measuring span: 10 : 1 Flow values: Values = 100% EN DN15 DN25 DN50 DN80 DN100 ASME Water: +20°C / +68°F Cone ½ 1" 2" 3" 4" Air: +20°C / +68°F, 1.013 bara / 14.7 psia Water [GPH] Air [SCFM] Pressure loss [psig] K 15.1 18.5 1.12 2.87 K 15.2 31.7 1.86 3.00 K 15.3 47.6 2.79 2.87 K 15.4 74.0 4.65 3.31 K 15.5 119 7.44 3.68 K 15.6 185 11.2 4.78 K 15.7 317 18.6 8.68 K 15.8 423 24.8 14.0 K 15.8 634 37.2 23.5 K 25.1 343 21.7 1.79 K 25.2 528 31.0 1.54 K 25.3 793 49.6 1.71 K 25.4 1321 80.6 2.13 K 25.5 2245 136 3.19 K 25.5 2642 161 4.94 K 55.1 2642 161 3.53 K 55.2 4227 260 3.38 K 55.3 5812 360 3.23 K 55.3 8982 558 6.17 K 85.1 6604 403 1.91 K 85.2 9246 589 1.91 K 85.2 15851 992 4.26 K 105.1 21134 1364 3.68 K 105.1 31701 1984 5.00 INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to SCFM or SCFH: Volume flow at standard (std.) conditions 15°C - 1.013 bara (ISO 13443) 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 81 8 TECHNICAL DATA H250 M40 H250U - Vertical installation position Measuring span: 10 : 1 Flow values: Values = 100% Flow direction Vertical downwards EN DN15 DN25 DN50 ASME Water: +20°C / +68°F Cone ½" 1" 2" Air: +20°C / +68°F, 1.013 bara / 14.7 psia Water [l/h] Pressure loss [mbar] Air [Nm3/h] K 15.1 65 1.6 175 K 15.2 110 2.5 178 K 15.3 170 4 180 K 15.4 260 6 200 K 15.5 420 10 220 K 15.6 650 16 290 K 15.7 1100 28 520 K 15.8 1500 40 840 K 25.1 1150 30 97 K 25.2 1800 45 85 K 25.3 2700 70 92 K 25.4 4500 120 115 K 25.5 7600 200 172 K 55.1 9000 240 220 K 55.2 15000 400 230 K 55.3 21000 550 240 INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to Nl/h or Nm3/h: Volume flow at standard (norm.) conditions 0°C - 1.013 bara (DIN 1343) 82 www.krohne.com 07/2016 - 4000640704 - MA H250-M40 R04 en TECHNICAL DATA 8 H250 M40 H250U - Vertical installation position Measuring span: 10 : 1 Flow values: Values = 100% Flow direction Vertical downwards EN DN15 DN25 DN50 ASME Water: +20°C / +68°F Cone ½" 1" 2" Air: +20°C / +68°F, 1.013 bara / 14.7 psia Water [GPH] Air [SCFM] Pressure loss [psig] K 15.1 17.2 0.99 2.57 K 15.2 29.1 1.55 2.62 K 15.3 44.9 2.48 2.65 K 15.4 68.7 3.72 2.94 K 15.5 111 6.20 3.23 K 15.6 172 9.92 4.26 K 15.7 291 17.4 7.64 K 15.8 396 24.8 12.3 K 25.1 304 18.6 1.42 K 25.2 476 27.9 1.25 K 25.3 713 43.4 1.35 K 25.4 1189 74.4 1.69 K 25.5 2008 124 2.53 K 55.1 2378 149 3.23 K 55.2 3963 248 3.38 K 55.3 5548 341 3.53 INFORMATION! The operating pressure should be at least double the pressure loss for liquids and five times for gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other flow ranges on request. Conversion of other media or operating data is performed using the calculation method in accordance with VDI/VDE directive 3513. Reference condition for gas measurements: Flow measurements for gases are attributed to SCFM or SCFH: Volume flow at standard (std.) conditions 15°C - 1.013 bara (ISO 13443) 07/2016 - 4000640704 - MA H250-M40 R04 en www.krohne.com 83 © KROHNE 07/2016 - 4000640704 - MA H250-M40 R04 en - Subject to change without notice. KROHNE – Process instrumentation and measurement solutions • • • • • • Flow Level Temperature Pressure Process Analysis Services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: www.krohne.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Trapped : False Producer : Acrobat Distiller 7.0 (Windows) GTS PDFX Version : PDF/X-3:2002 Print Driver : FrameMaker PDF printer 2.2.0.8 (11.09.2014 14:37:06) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2016:07:25 18:00:59+02:00 Create Date : 2016:07:13 11:43:36+02:00 Metadata Date : 2016:07:25 18:00:59+02:00 Format : application/pdf Title : MA_H250_M40_en_4000640704_R04.book Creator : depesamf Document ID : uuid:caaa55a9-76db-4032-a70a-ab23fbce2737 Instance ID : uuid:ea6292c7-b003-494e-928e-98cc6375ddac Page Layout : SinglePage Page Mode : UseThumbs Page Count : 84 Author : depesamfEXIF Metadata provided by EXIF.tools