Manual_Premium Alcomate Al7000 Manual

User Manual: alcomate-al7000-manual

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadManual_Premium Alcomate-al7000-manual
Open PDF In BrowserView PDF
The AlcoMate Premium (Model AL-7000) is our new flagship breathalyzer that provides you with the
most advanced, accurate and convenient breath testing system available. The Premium never requires
calibration through the use of patent-pending PRISMTM (Pre-calibrated Replaceable Intelligent Sensor
Module) Technology. With the unique easy-replace sensor panel, module replacement takes just a few
seconds!
The AlcoMate Premium’s PRISMTM Sensor Technology uses advanced next-generation components to
improve upon prior oxide semiconductor technologies and introduces a level of accuracy, reliability and
ease-of-use never before achieved among portable screening breathalyzers. Accessories for the BASIC
PACK include a pre-installed sensor module, batteries (x2), mouthpieces (x5) and compact carrying bag.
The FULL PACK additionally includes a field test kit (large zippered bag) and power car adapter.
Note: The only legally valid measure of %BAC (percent Blood Alcohol Concentration) is obtained by blood testing or other
evidential method of measurement. This device is for screening purposes only and should be used as a monitoring guide.
This device must be used strictly in accordance with the instructions provided with the product.

1

Device Operation
If you are using the AlcoMate Premium for the first time, please install two 1.5V AA batteries (included)
and attach a mouthpiece to the unit.

Instructions

Press and hold the

The cumulative test

The display may

The back-lit digital

Power Button to turn

count will be

alternately show

display shows

the unit on.

displayed as you hold

“nor”, which is short

results clearly

the Power Button

for normal operation.

during day or night

down.

conditions.

Release the Power

Secure your lips

If you see “Flow” in

If the device cannot

Switch. There will be a

around the

the display, the breath

take a successful

countdown as the unit

mouthpiece and blow

sample was not strong

sample, you will see

warms up. The display

sharply and steadily

or long enough for

“Out” in the display

will show “blow”

into the unit for about

measurement. Please

and the unit will

when ready.

4 seconds.

try again.

shut itself off.

Battery Replacement

The results will be

Remove the battery cover at the rear of the

Note: There is a

shown for about 15

unit and replace the old batteries with two

Mouthpiece Storage

seconds. The unit will

new 1.5V “AA” batteries. Make sure to

Slot between the

then shut itself off.

properly align the batteries by checking the +/-

batteries. The Slot

orientation.

holds 2 mouthpieces.

2

Sensor Module Replacement
Please take the following steps to install a new
sensor module. (VERY IMPORTANT: The
device MUST BE TURNED OFF in order to
avoid IMMEDIATE DAMAGE to the sensor.)

Open the easy-

You will see the

replace sensor panel.

sensor module.

Remove the module by

Insert a new sensor

Make sure the new

Close the easy-

pulling it straight

module in the

sensor module is

replace sensor panel.

back.

original position.

firmly secured.

Ready for testing!

Warnings
a.

WAIT AT LEAST 20 MINUTES AFTER EATING OR DRINKING BEFORE TESTING. A
breathalyzer examines “lung air” samples, not “mouth air” to calculate alcohol content. Any
“contaminants” in the mouth, including alcohol, food, smoke, or even excess saliva, may
interfere with testing. This includes alcohol-based mouthwash or similar products. This is the
most common cause of improper use and incorrect results.

b.

Avoid testing in high wind or enclosed spaces. Poor ventilation may also lengthen the time
required for warm up between tests.

c.

Do not blow smoke, saliva or other contaminants into the mouthpiece, as the sensor may
become damaged.

d.

Do NOT use the Premium as a tool to drink and drive.

e.

Keep out of extreme temperatures and out of the reach of children.

f.

To maintain accuracy, the sensor module inside the Premium must be replaced every 200 tests
or at least once yearly (whichever comes first). Large numbers of "high positive" (high
alcohol) readings may require replacing the module much sooner than normally expected.

g.

WARNING DISPLAY “Flow”: If you see “Flow” in the display, the breath sample was not
strong or long enough for measurement. As soon as you start blowing into the device, you
will hear a long beep indicating how long you should blow.

h.

WARNING DISPLAY “Cal”: If you see “Cal” in the display, the Premium needs a new sensor
module. If the cumulative test counter reaches 300 tests, the Premium will display Cal
automatically. Please purchase and install a new sensor module.

i.

WARNING DISPLAY “Bat”: If you see “Bat” in the display, the battery power is low. Please
replace the batteries.
3

Specifications
Method of Measure

BrAC (Breath Alcohol Content) to %BAC (percent Blood
Alcohol Concentration)

Range

0.000% to 0.400%BAC

Accuracy

+/-0.01% up to 0.10% BAC

Sensor

Advanced Oxide Semiconductor (2nd Generation)

Power

Two 1.5V AA alkaline batteries (included)

Testing Capacity

Approx. 100~200 with new batteries

Operating Temperature

10 – 40 degrees Celsius

Warm Up

Less than 1 minute

Display

4-digit back-lit LCD display (0.000%)

Size (mm)

4.2” x 2.0” x 0.75”

Weight

1.8 oz. (without batteries)

Sensor Modules

Sensor modules must be replaced every 200 tests or at
least once yearly, whichever comes first. Modules should
also be replaced if damaged or expired.

Warranty
The manufacturer warrants the product to be free from defects in workmanship or material (excluding
calibration) under normal use for twelve (12) months from the date of purchase. The manufacturer’s
obligation under this warranty is limited to replacing, adjusting or repairing the unit if returned along
with proof of purchase.
damaged.

This warranty is void if the unit has been tampered with or maliciously

Sensor Module replacement is a cyclical maintenance procedure that is required by the

AlcoMate Premium to maintain accuracy, and as such, is NOT covered under warranty.

Sensor

Module replacement eliminates the need for re-calibration (a non-warranty service which is also a
cyclical maintenance procedure) required by all traditional breathalyzers.

Technical Support and Service
For technical support, please contact us at:
Advanced Safety Devices, LLC
9140 Jordan Avenue
Chatswort, CA 91311
Toll-Free:

866-216-8700

(Monday-Friday 8AM to 5PM PST)

Tel:

818-701-9200

(Monday-Friday 8AM to 5PM PST)

Fax:

818-701-9220

Email:

service@safety-devices.com

Web:

http://www.safety-devices.com

4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2009:03:31 16:32:32Z
Creator Tool                    : PrimoPDF http://www.primopdf.com
Modify Date                     : 2010:04:05 12:33:07-07:00
Metadata Date                   : 2010:04:05 12:33:07-07:00
Format                          : application/pdf
Creator                         : Admin
Title                           : Microsoft Word - manual_Premium.doc
Producer                        : PrimoPDF
Document ID                     : uuid:92ab9a4f-1067-4aa3-88fe-2ca90784f699
Instance ID                     : uuid:c200a322-ae47-4213-a84b-82c962719531
Page Count                      : 4
Author                          : Admin
EXIF Metadata provided by EXIF.tools

Navigation menu