Manual_Premium Alcomate Al7000 Manual

User Manual: alcomate-al7000-manual

Open the PDF directly: View PDF PDF.
Page Count: 4

1
The AlcoMate Premium (Model AL-7000) is our new flagship breathalyzer that provides you with the
most advanced, accurate and convenient breath testing system available. The Premium never requires
calibration through the use of patent-pending PRISMTM (Pre-calibrated Replaceable Intelligent Sensor
Module) Technology. With the unique easy-replace sensor panel, module replacement takes just a few
seconds!
The AlcoMate Premium’s PRISMTM Sensor Technology uses advanced next-generation components to
improve upon prior oxide semiconductor technologies and introduces a level of accuracy, reliability and
ease-of-use never before achieved among portable screening breathalyzers. Accessories for the BASIC
PACK include a pre-installed sensor module, batteries (x2), mouthpieces (x5) and compact carrying bag.
The FULL PACK additionally includes a field test kit (large zippered bag) and power car adapter.
Note: The only legally valid measure of %BAC (percent Blood Alcohol Concentration) is obtained by blood testing or other
evidential method of measurement. This device is for screening purposes only and should be used as a monitoring guide.
This device must be used strictly in accordance with the instructions provided with the product.
2
Device Operation
If you are using the AlcoMate Premium for the first time, please install two 1.5V AA batteries (included)
and attach a mouthpiece to the unit.
Instructions
Press and hold the
Power Button to turn
the unit on.
The cumulative test
count will be
displayed as you hold
the Power Button
down.
The display may
alternately show
“nor”, which is short
for normal operation.
The back-lit digital
display shows
results clearly
during day or night
conditions.
Release the Power
Switch. There will be a
countdown as the unit
warms up. The display
will show “blow”
when ready.
Secure your lips
around the
mouthpiece and blow
sharply and steadily
into the unit for about
4 seconds.
If you see “Flow” in
the display, the breath
sample was not strong
or long enough for
measurement. Please
try again.
If the device cannot
take a successful
sample, you will see
“Out” in the display
and the unit will
shut itself off.
Battery Replacement
The results will be
shown for about 15
seconds. The unit will
then shut itself off.
Remove the battery cover at the rear of the
unit and replace the old batteries with two
new 1.5V “AA” batteries. Make sure to
properly align the batteries by checking the +/-
orientation.
Note: There is a
Mouthpiece Storage
Slot between the
batteries. The Slot
holds 2 mouthpieces.
3
Sensor Module Replacement
Please take the following steps to install a new
sensor module. (VERY IMPORTANT: The
device MUST BE TURNED OFF in order to
avoid IMMEDIATE DAMAGE to the sensor.) Open the easy-
replace sensor panel.
You will see the
sensor module.
Remove the module by
pulling it straight
back.
Insert a new sensor
module in the
original position.
Make sure the new
sensor module is
firmly secured.
Close the easy-
replace sensor panel.
Ready for testing!
Warnings
a. WAIT AT LEAST 20 MINUTES AFTER EATING OR DRINKING BEFORE TESTING. A
breathalyzer examines “lung air” samples, not “mouth air” to calculate alcohol content. Any
“contaminants” in the mouth, including alcohol, food, smoke, or even excess saliva, may
interfere with testing. This includes alcohol-based mouthwash or similar products. This is the
most common cause of improper use and incorrect results.
b. Avoid testing in high wind or enclosed spaces. Poor ventilation may also lengthen the time
required for warm up between tests.
c. Do not blow smoke, saliva or other contaminants into the mouthpiece, as the sensor may
become damaged.
d. Do NOT use the Premium as a tool to drink and drive.
e. Keep out of extreme temperatures and out of the reach of children.
f. To maintain accuracy, the sensor module inside the Premium must be replaced every 200 tests
or at least once yearly (whichever comes first). Large numbers of "high positive" (high
alcohol) readings may require replacing the module much sooner than normally expected.
g. WARNING DISPLAY “Flow”: If you see “Flow” in the display, the breath sample was not
strong or long enough for measurement. As soon as you start blowing into the device, you
will hear a long beep indicating how long you should blow.
h. WARNING DISPLAY “Cal”: If you see “Cal” in the display, the Premium needs a new sensor
module. If the cumulative test counter reaches 300 tests, the Premium will display Cal
automatically. Please purchase and install a new sensor module.
i. WARNING DISPLAY “Bat”: If you see “Bat” in the display, the battery power is low. Please
replace the batteries.
4
Specifications
Method of Measure BrAC (Breath Alcohol Content) to %BAC (percent Blood
Alcohol Concentration)
Range 0.000% to 0.400%BAC
Accuracy +/-0.01% up to 0.10% BAC
Sensor Advanced Oxide Semiconductor (2nd Generation)
Power Two 1.5V AA alkaline batteries (included)
Testing Capacity Approx. 100~200 with new batteries
Operating Temperature
10 – 40 degrees Celsius
Warm Up Less than 1 minute
Display 4-digit back-lit LCD display (0.000%)
Size (mm) 4.2” x 2.0” x 0.75”
Weight 1.8 oz. (without batteries)
Sensor Modules Sensor modules must be replaced every 200 tests or at
least once yearly, whichever comes first. Modules should
also be replaced if damaged or expired.
Warranty
The manufacturer warrants the product to be free from defects in workmanship or material (excluding
calibration) under normal use for twelve (12) months from the date of purchase. The manufacturers
obligation under this warranty is limited to replacing, adjusting or repairing the unit if returned along
with proof of purchase. This warranty is void if the unit has been tampered with or maliciously
damaged. Sensor Module replacement is a cyclical maintenance procedure that is required by the
AlcoMate Premium to maintain accuracy, and as such, is NOT covered under warranty. Sensor
Module replacement eliminates the need for re-calibration (a non-warranty service which is also a
cyclical maintenance procedure) required by all traditional breathalyzers.
Technical Support and Service
For technical support, please contact us at:
Advanced Safety Devices, LLC
9140 Jordan Avenue
Chatswort, CA 91311
Toll-Free: 866-216-8700 (Monday-Friday 8AM to 5PM PST)
Tel: 818-701-9200 (Monday-Friday 8AM to 5PM PST)
Fax: 818-701-9220
Email: service@safety-devices.com
Web: http://www.safety-devices.com

Navigation menu