CBA 300 SR80 Bettis Cba300 Ds
User Manual: SR80
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
CBA-300 Series Pneumatic Actuators Strong, Efficient and Cost Effective 3 11 ■ PED 97/23/EC Compliant ■ Suitable for SIL 2 and SIL 3 ■ Water Ingress Protected – IP66 and IP67M ■ Five-Year Warranty ■ NAMUR Topworks ■ ISO/DIN Bottom Mounting ■ Jackscrew Option 10 CBA-300 SERIES PNEUMATIC DESIGN AND CONSTRUCTION Introduction 13 For more than 45 years, Bettis valve actuators have demonstrated the latest technology. The CBA 300Series pneumatic actuators combine the strengths of our new generation G-Series scotch-yoke actuators, while incorporating several new design economies for efficient and cost effective operation. ® 1 4 2 The advanced 300-Series have enhanced water ingress and corrosion protection. These compact actuators are lightweight and ideally suited for automating virtually any quarter-turn (90-degree) rotating mechanism including ball, butterfly and plug valves. With a variety of options, the 300-Series can meet your most demanding valve automation needs. Operating Ranges Double-acting 300-Series actuators are available with guaranteed minimum torque outputs ranging from 7,388 lb-in to 20,337 lb-in (835 to 2,333 Nm). 300-Series spring-return models require pressure in only one direction of travel and are available for fail clockwise or counterclockwise applications. These models produce spring ending torques ranging from 2,532 lb-in through 10,457 lb-in (286 to 1,182 Nm). Standard construction 300-Series actuators are designed for operation temperatures ranging from -20°F to +200°F (-29°C to +93°C). Optional high temperature trim allows operation from 0°F to 350°F (-18°C to +177°C) and special non-PED low temperature trim permit operation to -40°F (-40°C). Pneumatic operating pressures for the 300-Series range from 40 to 150 PSIG (3 to 10 BAR). 2 Features and Advantages Water Ingress Protection – The 300-Series actuators meet both IP66 and IP67M specifications for submergence and severe high pressure water deluge test, offering superior water ingress and corrosion protection. The actuator has no gaskets and is totally o-ring sealed. 1) NAMUR Topworks – The 300-Series utilizes the internationally accepted NAMUR mounting configuration that allows standardization of accessory hardware and the direct or close coupling of NAMUR designed hardware and accessories. 2) New Quad Sealed Torque Shaft – The lower torque shaft has two independent seals – the outer seal protects the large bearing area and the primary, inner cup seal from the environment. The upper shaft bearing area features a bi-directional, double lip seal providing twice the level of protection from corrosion and contaminants. 3) New O-Ring Sealed Cylinders – The o-ring sealed cylinders essentially eliminate the possibility of any cylinder leakage throughout the full range of operating pressures and climatic conditions. 4) Name Plate – Long lasting stainless steel plate provides lifetime traceability and critical operating information. 5) Standard Accessory Mounting Pad – The new accessory mounting pad is standard and identical on all CBA and CBA 300-Series models, allowing for the panel mounting of controls. Standard stop screw 12 5 9 M-11 hydraulic override configuration 6 Jackscrew option (See insert for standard stop screw configuration) 8) Efficient All Bearing Design – The 300-Series piston has three field replaceable bearings. They include a TFE piston head bearing, PTFE/bronze bearings on either piston end and on the yoke pin. These bearings help to assure smooth and consistent torque output, while enhancing total cycle life capabilities. 9) Torque Shaft Bearing – The torque shaft features field replaceable upper and lower PTFE-coated, copper-clad metallic bearings. 7 8 6) Jackscrew Option (Shown) – A blowout-proof, economical jackscrew manual override is available with the 300-Series. When equipped with a jackscrew, it also acts as a stop adjustment screw. The jackscrew feature has several advantages: ■ Produces full rated torque output in the event of air supply loss. ■ Available with or without handwheel, locking devices and many other options. Consult factory. ■ The manual override absorbs impact loads at maximum recommended actuator speeds. ■ Double-acting models are available with one or two jackscrews. Bi-directional Travel Stops – Dual stops allowing 80° to 100° total travel adjustment. This feature provides an unmatched travel range to assist in prolonging valve seat integrity. Optional Bi-directional Extended Travel Stop (ETS) – Allows 0° to 100° extended travel adjustment capability, and can be used as a lockout device. Consult factory. 7) ISO/DIN Actuator/Valve Interface – The 300-Series has an ISO/DIN F14 mounting configuration. This female interface allows close coupling or direct mounting of the actuator to the valve topworks. 10) Xylan™ Cylinder Coating – This fluoropolymer (TFE-based) coating is highly resistant to corrosion and thermal shock. It also provides for excellent lubricity, adding significantly to piston seal life and actuator efficiency. Xylan has been laboratory (ASTM B117) tested and field proven to be extremely resistant to contaminants typically found in instrument air supply systems. 11) Springs – High-strength, high-performance alloy carbon steel springs are protected by Tactyl 50, a pliable self-healing coating. Bettis takes and additional step and shot peens the springs, helping to extend the actuator’s spring cycle life. 12) Ductile Iron Housing – CBA actuator housings are made of pressure vessel quality ductile iron which is approved for use by ASME and the Pressure Equipment Directive (PED 97/23/EC). All housings have been optimized by finite element analysis and are designed for light weight while retaining maximum strength, ductility and corrosion resistance. 13) Center Bar and Torque Shaft – Utilizes a proprietary surface conversion process, producing an extremely hard surface exhibiting excellent wear and corrosion resistance. The center bar guides the piston throughout its full stoke, preventing metal to metal contact with the cylinder bore. 3 SIZING AND SELECTION General Definitions Actuator Selection Procedures To clarify and standardize terminology, Bettis offers the following definitions for terms commonly used. Please become familiar with and use the following standard definitions when referring to Bettis quarter-turn actuators. A) Determine the type of Bettis actuator required: double-acting or spring-return. Quarter-turn: A device which rotates a minimum of 90 degrees. All Bettis quarter-turn actuators will rotate more than 90 degrees. C) Using this information, select the applicable torque rating table and see the appropriate following examples. Position: That degree of rotation describing an actuator’s current location. The mid position of a quarter-turn actuator is generally at forty-five(45) degrees. Scotch-Yoke, Double-Acting Actuators (example assumes CW to close) CW: Clockwise rotation. CCW: Counterclockwise rotation. Stroke: A continuous, ninety (90) degree rotation of a quarter-turn actuator. Bettis spring-return actuators have two (2) different strokes, a pressure stroke and a spring stroke. Bettis doubleacting actuators have two (2) pressure strokes. Note that rack and pinon actuators have common torque valves for both pressure strokes, while scotch yoke actuators have different torque values depending on which side of the piston is doing the work. Cycle: The collective reference to two (2) strokes, one (1) for clockwise (CW) rotation and one (1) for counterclockwise (CCW) rotation. Bettis actuators must rotate through two (2) stroke to complete one (1) cycle. Safety Factor: Represents a protective component (an adjustment to torque requirement) sometimes added to a valve’s required torque value. Often used when the user/specifier is not certain of the valve’s torque requirements, or because of other application concerns. Sizing Bettis Actuators The following information is generally the minimum required for sizing Bettis quarter-turn pneumatic and hydraulic actuators for specific valve requirements. A) An accurate maximum torque requirement must be obtained before actuator sizing begins. Normal maximum stem torque for a properly applied and maintained valve is usually defined as: The maximum starting torque required to rotate the valve element (ball, disc,plug, etc.) from a fully closed position (unsealing), against the maximum normal valve rated different pressures. Most valve manufacturers make adjustments in the form of torque amendments under various operating conditions. Application operating conditions such as temperature extremes, actual differential pressure, unusual loading, high flow rates, operating speeds, etc. are some of the most common causes for adjustments. Bettis recommends that the valve manufacturer supply the maximum required torque value(s) (including any adjustments or suggested safety factors). Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation (CCW or CW) these maximum requirements occur. B) Bettis actuators include stops which will resist the maximum rated torque output of the actuator. The possibility exists, that should the valve become immobilized during rotation, the actuator could exceed the maximum allowable valve input torque rating. If this possibility is a concern, your application needs further review. Once the maximum torque requirements, its position, and direction of rotation are identified, the appropriate Bettis actuator can be selected from torque output charts on pages 4–7. 4 B) Determine the power supply media: pneumatic or hydraulic, and the minimum/maximum supply pressure(s) at the actuator. Note: The valve’s torque requirements must be exceeded by the actuator’s torque output at all corresponding positions and directions of rotation. Bettis has included Start, Minimum, and End pressure torque outputs for your use. A) Using your minimum operating pressure, select an operating pressure column from the Pressure Torque Rating Section of less than or equal pressure. Move down the column until both starting and minimum output torques are found which exceed the valve’s maximum and minimum torque requirements. Determine the Bettis model number at the left, under the model number column. B) Once a Bettis actuator model has been selected, use the performance data tables to ensure your maximum supply pressure does not exceed the maximum operating pressure (M.O.P.) for your Bettis actuator. If the actuator selected is not rated for your maximum supply pressure, either the maximum supply pressure must be reduced or an actuator rated for a higher M.O.P. must be selected. Scotch-Yoke, Spring-Return, Fail CLOCKWISE Actuators (example assumes CW to close) Note: The valve’s maximum torque requirements must be exceeded by the actuator’s torque output at all corresponding positions and directions of rotation. Bettis has included Start, Minimum, and End Spring Torque outputs, as well as Start, Minimum and End Pressure Torque Outputs for your use. The minimum torque outputs listed on the Spring-Return torque charts are the lowest value of torque output available at any position, during either stroke (pressure or spring). A) Select from the Spring Torque column a Spring Ending torque output which exceeds that of the valve’s maximum seating requirement. B) Proceed to the right using your minimum operating pressure and select an operating pressure column from the Pressure Torque Rating Section of less than or equal pressure. The Pressure Start torque output must exceed the valve’s torque requirement at this position (unseating). The Pressure End torque output must exceed the valve’s torque requirement at this position (full flow) and direction of rotation (CCW). C) Once a Bettis actuator model has been selected, use the performance data tables to ensure your maximum supply pressure does not exceed the maximum operating pressure (M.O.P.) for your Bettis actuator. If the actuator selected is not rated for your maximum supply pressure, either the maximum supply pressure must be reduced or an actuator rated for a higher M.O.P. must be selected. Contact your local Authorized Bettis distributor or a Bettis manufacturing facility if you require assistance. Performance Data – CBA-300-Series (Pneumatic) - Imperial & metric Double-Acting Actuators CBA-Series Volumes Actuator Model Outboard Cu. Inches CBA 730 CBA 830 CBA 930 CBA 1030 Inboard (Housing) Cubic CM 260 341 433 572 4260.6 5588.0 7095.6 9373.4 Maximum System Pressure (MSP)* Maximum Operating Maximum Allowable Approximate Weight Pressure Working Pressure of Actuator (MOP)** (MAWP)*** Cu. Inches Cubic CM PSIG Bar PSIG Bar PSIG Bar Lbs. KG 562 633 713 834 9209.5 10373.0 11683.9 13666.8 120 90 70 55 8.3 6.2 4.8 3.8 105 80 65 50 7.2 5.5 4.5 3.4 200 200 170 130 13.8 13.8 11.7 9.0 130 140 155 170 59 63.5 70.3 77.1 Spring-Return Actuators CBA-Series Cu. Inches ◆CBA 730- SR40 SR60 SR80 SR100 ◆CBA 830- SR40 SR60 SR80 SR100 ◆CBA 930- SR40 SR60 SR80 SR100 ◆CBA 1030- SR40 SR60 SR80 — Maximum System Pressure (MSP)* Volume Actuator Model 562 562 562 562 633 633 633 633 713 713 713 713 834 834 834 — Cubic CM 9209.5 9209.5 9209.5 9209.5 10373.0 10373.0 10373.0 10373.0 11683.9 11683.9 11683.9 11683.9 13666.8 13666.8 13666.8 — 150 155 160 165 125 125 130 140 120 120 120 120 95 100 110 — 10.3 10.7 11.0 11.4 8.6 8.6 9.0 9.7 8.3 8.3 8.3 8.3 6.5 6.9 7.6 — Maximum Operating Pressure (MOP)** Maximum Allowable Working Pressure (MAWP)*** Approximate Weight of Actuator PSIG Bar PSIG Bar Lbs. 135 140 145 150 105 110 115 120 85 90 95 105 70 75 80 — 9.3 9.7 10.0 10.3 7.2 7.6 8.0 8.3 5.9 6.2 6.6 7.2 4.8 5.2 5.5 — 200 200 200 200 200 200 200 200 170 170 170 170 130 130 130 — 13.8 13.8 13.8 13.8 13.8 13.8 13.8 13.8 11.7 11.7 11.7 11.7 9.0 9.0 9.0 — 158 160.5 163 164 180 184.5 188 192.5 195 202 206.5 205 220 225.5 233.5 KG 71.7 72.8 73.9 74.4 81.6 83.7 85.3 87.3 88.5 91.6 93.7 93.0 99.8 102.5 105.9 Notes: ◆ ▲ CBA-SRXXM mechanical handwheel overrides are available on these models. The override adds approximately 2 lbs. (.8 kg) to the weight of the standard CBA model. Maximum volume including cavity required for calculating consumption per stroke. * ** Maximum System Pressure (MSP) – The maximum allowable system supply pressure to which the actuator may be exposed. Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque of the actuator. *** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to a fully stroked actuator against the travel stops. Standard installation produces clockwise rotation when the outboard side of piston is pressurized. Standard installation produces counterclockwise rotation when the inboard side of piston is pressurized. Note: Actuator may be installed opposite of that shown above. 5 Torque Ratings – CBA-300-Series (Pneumatic) - Imperial All Published Torques are Typical Minimum Values. Double-Acting Actuators Actuator Model CBA730 CBA830 CBA930 CBA1030 Stroke Position Start/End Minimum Start/End Minimum Start/End Minimum Start/End Minimum 40 50 7388 4248 9697 5575 12313 7080 16270 9355 9235 5310 12121 6969 15391 8850 20337 11694 Operating Pressure (PSIG) 60 70 80 90 Pressure Torque Output Start/Min./End (lb-in) 11082 6372 14545 8363 18470 10620 12929 7434 16969 9757 14776 8496 19393 11151 16623 9558 100 110 18470 10620 Spring-Return Actuators Actuator Model CBA730-SR40 CBA730-SR60 CBA730-SR80 CBA730-SR100 CBA830-SR40 CBA830-SR60 CBA830-SR80 CBA830-SR100 CBA930-SR40 CBA930-SR60 CBA930-SR80 CBA930-SR100 CBA1030-SR40 CBA1030-SR60 CBA1030-SR80 6 Spring Torque (in-lbs) Start/Min./End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End 4383 1759 2532 6748 2625 3732 9340 3450 4576 11755 4301 5792 5739 2330 3318 9010 3443 4637 12171 4565 5978 15438 5677 7218 7471 3063 4317 11942 4470 5586 15872 5977 7523 19822 7500 9498 9929 4036 5629 15924 5839 7108 20580 7978 10457 40 50 60 4589 1808 2544 6436 2782 4391 5225 1704 1892 8283 3747 6238 7095 2709 3762 6029 2406 3354 7849 3163 4364 10455 4178 5703 8453 3700 5778 7299 2216 2226 11004 4866 7519 9602 2577 2577 14624 6431 9872 12989 3245 3245 10877 4982 8202 9783 3587 4711 14159 6551 10674 12757 4691 5732 18793 8658 14041 17159 6204 7415 Operating Pressure (PSIG) 70 80 90 100 110 120 Pressure Torque Output Start/Min./End (lb-in) 10130 4712 8085 8965 3692 5632 8033 2565 2767 13301 6263 10626 12268 4898 7196 10786 3400 3605 17315 8237 13829 15912 6425 8888 13771 4442 4544 22962 10885 18210 21328 8507 11584 17626 5937 6438 11977 5677 9932 10835 4657 7502 9903 3591 4637 15725 7545 13050 14753 6189 9680 13271 4772 6089 20470 9922 16985 19067 8145 12043 16927 6258 7699 21796 8299 10607 13824 6641 11779 12705 5622 9372 11773 4578 6507 10637 3499 4046 18149 8826 15474 17237 7471 12165 15756 6083 8574 14385 4560 4873 15671 7599 13626 14575 6587 11242 13643 5564 8377 12530 4513 5939 20573 10099 17899 19722 8753 14650 18241 7394 11059 16870 5935 7358 22223 9830 15194 20082 7993 10854 17899 6009 6489 21054 7808 9644 17518 8557 15473 16445 7552 13112 15513 6529 10247 14423 5500 7832 19365 9515 17319 18315 8517 14982 17383 7494 12117 16316 6488 9725 22207 10035 17135 20725 8679 13544 19354 7258 9842 21839 8569 12327 130 140 150 21212 10473 19166 20185 9483 16852 19253 8459 13987 18210 7458 11619 22055 10446 18722 21123 9424 15857 20103 8423 13512 21996 9388 15405 Torque Ratings – CBA-Series (Pneumatic) - metric All Published Torques are Typical Minimum Values. Double-Acting Actuators Actuator Model CBA730 CBA830 CBA930 CBA1030 Stroke Position Start/End Minimum Start/End Minimum Start/End Minimum Start/End Minimum 3 3.5 908 522 1192 685 1513 870 2000 1150 1059 609 1390 799 1766 1015 2333 1341 Operating Pressure (PSIG) 4 5 5.5 6 Pressure Torque Output Start/Min./End (lb-in) 1211 696 1589 914 2018 1160 1513 870 1986 1142 1665 957 2185 1256 7 1816 1044 2384 1371 8 2119 1218 2421 1392 Spring-Return Actuators Actuator Model CBA730-SR40 CBA730-SR60 CBA730-SR80 CBA730-SR100 CBA830-SR40 CBA830-SR60 CBA830-SR80 CBA830-SR100 CBA930-SR40 CBA930-SR60 CBA930-SR80 CBA930-SR100 CBA1030-SR40 CBA1030-SR60 CBA1030-SR80 Spring Torque (Nm) Start/Min/End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End Start Min. End 495 198 286 763 297 422 1055 390 517 1328 486 654 648 263 375 1017 389 524 1375 516 675 1744 641 816 844 346 488 1349 505 631 1793 675 850 2240 847 1073 1122 456 636 1799 660 803 2325 901 1182 Operating Pressure (Bar) 3 3.5 592 204 361 743 314 512 606 193 230 777 272 475 976 418 674 846 250 273 1012 357 618 1271 550 877 1112 291 318 1347 472 810 1688 727 1151 1504 367 403 4 5 5.5 6 7 Pressure Torque Output Start/Min./End (Nm) 894 1197 1348 1500 1802 423 532 641 750 859 663 966 1117 1269 1571 760 1066 1219 1373 1679 306 417 526 635 744 383 690 843 996 1302 961 1114 1267 1574 290 406 517 629 366 519 672 979 1138 1448 395 510 393 704 1175 1572 1770 1969 2366 563 708 853 997 1141 872 1270 1468 1667 2064 1050 1457 1660 1864 2271 405 553 699 844 989 476 884 1087 1291 1698 1289 1493 1697 2104 384 539 687 835 478 682 885 1292 1542 1949 515 671 467 874 1529 2046 2305 740 931 1121 1135 1652 1911 1371 1888 2146 2405 530 726 920 1111 577 1094 1352 1611 1646 1904 2163 502 707 903 603 862 1120 1916 2433 679 882 627 1144 2030 978 1493 1845 2528 701 961 744 1427 2110 2452 671 938 846 1187 8 9 10 2105 967 1874 1986 853 1609 1880 738 1285 1759 622 1014 2408 1075 2177 2292 962 1915 2187 847 1592 2069 733 1324 2493 956 1898 2379 843 1634 11 2511 981 1699 2356 820 1281 7 Dimensions – CBA-300-Series (Pneumatic) - in/mm Metric dimensions in parentheses Double-Acting Actuators CBAX30 Actuator Model CBA 730-SRX CBA 830-SRX CBA 930-SRX CBA 1030-SRX B In. 3.00 3.50 4.00 4.50 A In. 7.63 8.63 9.63 10.88 Spring Return Actuators CBAX30-SRX A Actuator Model CBA 730-SRX CBA 830-SRX CBA 930-SRX CBA 1030-SRX 8 In. 7.69 8.69 9.69 11.00 MM 195.3 220.7 246.1 279.4 A MM 193.8 219.2 244.6 276.4 B MM 76.2 88.9 101.6 114.3 Dimensions – CBA-300-Series (Pneumatic) - in/mm M3(HW) Overrides Metric dimensions in parentheses Double Acting Actuators – CBAX30-M3(HW) Actuator Model CBA 730-M3HW CBA 830-M3HW CBA 930-M3HW CBA 1030-M3HW B In. 3.00 3.50 4.00 4.50 A In. 7.63 8.63 9.63 10.88 A MM 193.8 219.2 244.6 276.4 B MM 76.2 88.9 101.6 114.3 M3/M3HW – This Jackscrew manual override is a mechanical advantage device threaded through a special adapter or the end cap of the CBA-300 Series cylinder to exert linear thrust on the actuator’s piston rod. The Jackscrew override is available for all CBA-300 models with or without handwheel. Spring Return Actuators – CBAX30-SRX-M3(HW) A Actuator Model CBA 730-SRX-M3HW CBA 830-SRX-M3HW CBA 930-SRX-M3HW CBA 1030-SRX-M3HW In. 7.69 8.69 9.69 11.00 MM 195.3 220.7 246.1 279.4 9 Dimensions – CBA-300-Series (Pneumatic) - in/mm Metric dimensions in parentheses Double-Acting Actuators CBAX30-M11 Spring Return Actuators CBAX30-SRX-M11 M11 – This hydraulic manual override is a compact modular system designed for use with all CBA-300 pneumatic Series actuators. The override can be used on either spring-return or double-acting models and can be applied to pneumatic or hydraulic units. Remote mount units are available, consult factory. 10 M-11 Override Dimensions – CBA-300-Series (Pneumatic) - in/mm M-11 Override Metric dimensions in parentheses Options SIL-PAC™ – The unique SIL-PAC solution provides a complete hardware and Bettis-supplied documentation package,embracing IEC, ISA and OSHA standards, for use in a SIL application. The CBA-300 Series actuators have a Failure Modes and Effects Diagnostics Analysis (FMEDA) report performed by Exida.com™ for SIL suitability. They can be combined with other components such as solenoid valves, switches and regulators. When Fisher’s TÜV-certified FIELDVUE® DVC controller is added, SIL-PAC is capable of partial stroke testing PLUS providing continuous monitoring of supply pressure, valve position and pressure values to the actuator to verify its proper working condition. The SIL-PAC package can then be mounted on the appropriate quarter-turn valve for SIL1, 2 or 3 applications. Bettis Automated Packages Bettis offers complete packages as a solution for final valve control. Bettis has the capability to combine the CBA-300 actuator, necessary controls and selected valve into a single system – perfect for large international projects. With this capability, Bettis can integrate its products with the complete offering of control options, including world-class PlantWeb® digital plant architecture and the entire range of Emerson automation solutions. BettiSystemsTM – Bettis has pre-engineered and documented a series of commonly required control systems. These approved systems utilize standard components, reduce lead times, and simplify purchasing, installation and start-up. Please consult the factory for additional information. 11 ORDERING / MODEL DESIGNATION OPTIONAL FEATURES Spring-Return Example Double-Acting Example Fail-Safe Operation CBA 7 30 SR80-M3-CW CBA 9 30 M3HW Bettis 300-Series actuators are capable of fail-safe operation using either stored compressed air (air fail safe) or a mechanical spring. Fail “CW” Jackscrew without handwheel Spring-Return, nominal 80 psig Jackscrew without handwheel Nominal Moment Arm (e.g. 3.0 In.) Nominal Moment Arm (e.g. 3.0 In.) Nominal Cylinder Size (In.) Nominal Cylinder Size (In.) Center Bar Center Bar Trims Trim options for the 300-Series actuators include high temperature, low temperature, no copper or no yellow metal trims. Consult factory with your trim requirements. Contact Us: Emerson Process Management, Valve Automation facilities at your nearest location: North & South America Europe Middle East & Africa 18703 GH Circle PO Box 508 Waller, Texas 77484 USA T +1 281 727 5300 F +1 281 727 5353 Asveldweg 11 7556 BT Hengelo(O) The Netherlands T +31 74 256 1010 F +31 74 291 0938 2 Monteer Road, Isando Kempton Park, 1600 South Africa T +27 11 974 3336 F +27 11 974 7005 Siemensring 112 D-47877 Willich Germany T +49 2154 499 660 F +49 2154 499 6613 PO Box 17033 Jebel Ali Free Zone Dubai, United Arab Emirates T +971 4883 5235 F +971 4883 5312 2500 Park Avenue West Mansfield, Ohio 44906 USA T +1 419 529 4311 F +1 419 529 3688 9009 King Palm Drive Tampa , Florida 33619 USA T +1 813 630 2255 F +1 813 630 9449 30/36 Allee du Plateau 93250 Villemomble France T +331 48 122610 F +331 48 122619 Asia Pacific 4112-91A Street Edmonton, Alberta T6E5V2 Canada T +1 780 450 3600 F +1 780 450 1400 6 Bracken Hill South West Industrial Estate Peterlee, Co Durham SR82LS, United Kingdom T +44 191 518 0020 F +44 191 518 0032 Av. Hollingsworth,325 Iporanga Sorocaba, SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 3 Furze Court 114 Wickham Road Fareham, Hampshire PO167SH ,United Kingdom T +44 132 984 8900 F +44 132 984 8901 19, Kian Teck Crescent, Singapore 628885 T +65 6262 4515 F +65 6268 0028 9/F Gateway Building No.10 Ya Bao Road Chaoyang District Beijing, P.R. China T +86 10 5821 1188 F +86 10 5821 1100 No 15 Xing Wang Road Wuqing Development Area Tianjin 301700 P.R. China T +86 22 8212 3300 F +86 22 8212 3308 Lot 13111, Mukim Labu, Kawasan Perindustrian Nilai 71807 Nilai, Negeri Sembilan Malaysia T +60 6 799 2323 F +60 6 799 9942 471 Mountain Highway Bayswater, Victoria 3153 Australia T +61 3 9721 0200 F +61 3 9720 0588 301, Solitaire Corporate Park 151, M.V. Road, Andheri(E) Mumbai-400093, Maharashtra, India T +91 22 6694 2711 F +91 22 2825 3394 NOF Shinagawa Konan Building 1-2-5, Higashi-shinagawa Shinagawa-Ku, Tokyo 140-0002 Japan T +81 3 5769 6873 F +81 3 5769 6902 © 2008 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. “Brand mark listing” are marks of one of the Emerson Process Management family of companies. All other marks are property of their respective owners. The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. The color orange, U.S. Reg. No. 2,739,393, is a registered trademark of the Bettis Corporation. www.Bettis.com Bettis Brochure # 22.00-5 REV: 6-08 2.5M/6-08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 2008:06:04 16:20:23Z Creator Tool : QuarkXPress(R) 7.31 Modify Date : 2009:07:10 16:15:01-07:00 Metadata Date : 2009:07:10 16:15:01-07:00 Producer : QuarkXPress(R) 7.31 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments Format : application/pdf Title : CBA-300 Document ID : uuid:cb306033-8117-3f4d-a57f-0b58f3827a5c Instance ID : uuid:d7b88d99-82f7-417a-a6f6-011a9e8ae0fa Has XFA : No Page Count : 12 Creator : QuarkXPress(R) 7.31EXIF Metadata provided by EXIF.tools