SIMATIC ET 200 For Distributed Automation Solutions Brochure Et200 En
User Manual: ET 200
Open the PDF directly: View PDF .
Page Count: 60
Download | |
Open PDF In Browser | View PDF |
© Siemens AG 2012 SIMATIC ET 200 For distributed automation solutions SIMATIC Distributed I/O Brochure Edition November 2012 Answers for industry. © Siemens AG 2012 SIMATIC ET 200 With SIMATIC ET 200 a wide range of distributed I/O systems is available - for solutions in the control cabinet or without a control cabinet directly at the machine, as well as for applications in hazardous areas. The modular design allows the ET 200 system to be scaled up and expanded in small, easy steps: digital and analog inputs/outputs, intelligent modules with CPU functionality, safety engineering, motor starters, pneumatic systems, frequency converters, and diverse technology modules. In a control cabinet (IP20) ET 200SP A new generation of scalable I/O ET 200S Discretely modular design and multifunctional from page 18 from page 22 ET 200MP The multi-channel and multi-functional IO-device of the S7-1500 from page 29 Without control cabinet (IP65/67) ET 200pro Modular design and multifunctional from page 42 2 SIMATIC ET 200 ET 200eco PN Low-cost, space-saving block I/O from page 50 ET 200eco Low-cost, digital block I/O from page 51 ET 200M Modular design with S7-300 modules from page 33 © Siemens AG 2012 Contents Communication over PROFINET and PROFIBUS, uniform engineering, transparent diagnostic possibilities as well as optimal interfacing to SIMATIC controllers and HMI units prove the unique integration of Totally Integrated Automation. Totally Integrated Automation . . . . . . . . . . . . . . . . 4 System characteristics . . . . . . . . . . . . . . . . . . . . . . . 6 SIMATIC ET 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Distributed automation . . . . . . . . . . . . . . . . . . . . . . . 8 Product range at a glance . . . . . . . . . . . . . . . . . . . . 10 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ET 200iSP Intrinsically safe version for hazardous area ET 200 - characteristics . . . . . . . . . . . . . . . . . . . . . . 14 Solutions in the control cabinet . . . . . . . . . . . . . . 18 SIMATIC ET 200SP . . . . . . . . . . . . . . . . . . . . . . . . . . 18 from page 37 SIMATIC ET 200S . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 SIMATIC ET 200MP . . . . . . . . . . . . . . . . . . . . . . . . . . 29 SIMATIC ET 200M . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SIMATIC ET 200iSP . . . . . . . . . . . . . . . . . . . . . . . . . 37 Solutions without a control cabinet . . . . . . . . . . . 42 SIMATIC ET 200pro . . . . . . . . . . . . . . . . . . . . . . . . . 42 SIMATIC ET 200eco PN . . . . . . . . . . . . . . . . . . . . . . . 50 SIMATIC ET 200eco . . . . . . . . . . . . . . . . . . . . . . . . . 51 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 SIMATIC overview . . . . . . . . . . . . . . . . . . . . . . . . . 59 Highlights ■ Multifunctional ■ Modular ■ Discretely scalable ■ Networking via PROFINET and PROFIBUS SIMATIC ET 200 3 © Siemens AG 2012 Totally Integrated Automation Rely on new productivity standards for sustained competitive advantages 4 Totally Integrated System features Automation © Siemens AG 2012 To be able to respond to the increasing international competitive pressure, it is more important than ever to consistently make full use of the potential for optimization – over the complete lifecycle of a machine or plant. Optimized processes reduce the total cost of ownership, shorten the time to market, and improve quality. This perfect balance between quality, time, and costs is now, more than ever, the decisive success factor in industry. Totally Integrated Automation is optimally aligned to all requirements and open for international standards and third-party systems. With its six characteristic system features, Totally Integrated Automation supports the complete lifecycle of a machine or plant. The complete system architecture offers holistic solutions for every automation segment on the basis of a comprehensive range of products. SIMATIC: more efficient and systematic automation SIMATIC, a core component of Totally Integrated Automation, includes a variety of standardized, flexible, and scalable products – such as the distributed I/O devices of the SIMATIC ET 200 portfolio presented in this brochure. SIMATIC is currently considered to be the global number one in automation. One of the decisive reasons for this is that SIMATIC exhibits the six system features of Totally Integrated Automation: • Engineering • Communication • Diagnostics • Safety • Security • Robustness In addition, SIMATIC features two additional system features: • Technology • High availability As an integral part of the SIMATIC range, the SIMATIC ET 200 distributed I/O system can offer you a host of benefits that are described in detail on the following pages. System features Totally Integrated Automation 5 © Siemens AG 2012 System features Engineering Maximum engineering efficiency – in all phases of the lifecycle of the machine and plant With SIMATIC you rely on an integrated engineering environment. Efficient software supports you over the complete lifecycle of your machine or plant – from the planning and design stages through configuring and programming as far as commissioning, operation and upgrading. With its integration capability and harmonized interfaces, SIMATIC software supports a high degree of data consistency – throughout the entire engineering process. Siemens has redefined engineering with its Totally Integrated Automation Portal (TIA Portal). The new TIA Portal engineering framework combines the SIMATIC STEP 7, SIMATIC WinCC and SINAMICS Startdrive automation software tools in a unique development environment. Communications Maximum data transparency on all automation levels – based on proven standards SIMATIC creates the foundations for unlimited integration in communication – and thus for maximum transparency on all levels, from the field and control level to the operations management level all they way up to the corporate management level. SIMATIC relies on international, cross-vendor standards which can be combined flexibly: PROFINET, the leading Industrial Ethernet standard and PROFIBUS, the global No. 1 fieldbus. Diagnostics Minimization of downtimes – through efficient diagnostic concepts All SIMATIC products feature integrated diagnostic functions with which a fault can be identified and eliminated to provide increased system availability. Even with larger plants, the Maintenance Station provides you with a uniform view of the maintenance-relevant information of all automation components. Safety Protection of personnel and machines – within the framework of an integrated complete system SIMATIC Safety Integrated offers TÜV-certified products, which facilitate compliance with relevant standards: IEC 62061 up to SIL 3, EN ISO 13849-1 up to PL e, as well as EN 954-1. Due to the integration of safety technology in standard technology, only one controller, one I/O, one engineering, and one bus system are required. Thus the system advantages and comprehensive functionality of SIMATIC are also available for fail-safe applications. 6 System features © Siemens AG 2012 Security Data security in the networked world – through harmonized, scalable security systems Due to the increased use of Ethernet connections penetrating the field level, security issues are gaining in importance in industry. For comprehensive protection of a plant, a variety of suitable measures must be implemented. These range from the company organization and its guidelines regarding protective measures for PC and control systems through to protection of automation cells by segmenting the network. Siemens follows the cell protection concept and, with the modules of the SCALANCE series and the Security modules, offers components for building up protected cells. www.siemens.com/industrialsecurity Robustness Maximum industrial suitability – through increased robustness Each standard product from the SIMATIC range is characterized by the highest quality and robustness and is perfect for use in industrial environments. Specific system tests ensure the planned and required quality. SIMATIC components meet all relevant international standards and are certified accordingly. Temperature and shock resistance are defined in the SIMATIC quality guidelines, as are vibration resistance or electromagnetic compatibility. For demanding to extreme rated conditions, special versions such as SIPLUS extreme or special versions of SIMATIC ET200 are available. These include an increased degree of protection, extended temperature ranges, and exceptional environmental stress. Technology More possibilities, less complexity – through integrated technology functionality Counting and measuring, cam control, closed-loop control, or motion control: You can integrate technological tasks in many different combinations and with various degrees of complexity without a system changeover into the world of SIMATIC – easily, conveniently, consistently. Parameter assignment and programming are implemented in the familiar STEP 7 environment. High availability Maximum availability – with integrated high availability concepts Siemens offers a comprehensive high availability concept to ensure high availability for the entire plant: from the field level to the control level all the way up to the management level. For example, field-tested controllers ensure high availability through bumpless switching with automatic event synchronization. www.siemens.com/simatic-system-properties System features 7 © Siemens AG 2012 Distributed automation The right solution for any requirement You are constantly on the look out for possibilities of optimizing production and reducing costs? With increasing competition it is essential to provide individual machinery and plants as fast and cost-effectively as possible? This starts with the design of your machine and continues through installation, commissioning and normal operation right up to maintenance. Uniform engineering, comprehensive functionality, simple installation and high-precision diagnostics from any point in the plant are essential – and it all needs to be based on international standards. Ahead of the competition thanks to consistent decentralization Flexible, distributed solutions are an essential part of modern automation – solutions that are tailored to your requirements and permit significant cost savings. Whether compact or modular, purely digital I/O interfaces or complete distributed systems with drive technology, direct in harsh industrial environments. In a control cabinet (IP20) 8 SIMATIC ET 200 – the right solution for every application With SIMATIC ET 200 a wide range of distributed I/O systems is available - for solutions in the control cabinet or without a control cabinet directly at the machine, as well as for applications in hazardous areas. SIMATIC ET 200 systems for cabinetfree configurations are installed in a rugged, fiber-glass reinforced plastic enclosure, making them resistant to shock and dirt, as well as watertight. Furthermore, you need fewer additional components, save on cabling, and profit from extremely fast response times. The modular design makes it possible to scale and expand the ET 200 systems simply and in small stages. Already integrated add-on modules reduce costs, and at the same time offer a widely diverse range of possible applications. You can choose from many different combination options: digital and analog inputs/outputs, intelligent modules with CPU functionality, safety engineering, motor starters, pneumatic systems, frequency converters, and diverse technology modules. Communication over PROFINET and PROFIBUS, uniform engineering, transparent diagnostic possibilities as well as optimal interfacing to SIMATIC controllers and HMI units prove the unique integration of Totally Integrated Automation. Without control cabinet (IP65/67) Scalable Multifunctional Compact and expandable Multifunctional Block Block ET 200SP ET 200S ET 200S COMPACT ET 200pro ET 200eco PN ET 200eco Multi-channel Modular Intrinsically-safe ET 200MP ET 200M ET 200iSP Distributed automation © Siemens AG 2012 Distributed fieldbus systems are elementary components of the automation landscape Communication is performed at the field level with PROFINET and PROFIBUS – these systems ensure rapid data transfer between the components and consistent decentralization of the automation solution. In addition to the fieldbus systems, the point-to-point connection I/O-Link is also available for intelligent connection of sensors and actuators. The use of open communication standards offers flexible connection possibilities – whichever system you decide on. You also have flexibility with the ET200 systems – most systems communicate both over PROFINET and PROFIBUS. Distributed fieldbus systems Management level Office environment Cell level PROFINET PROFIBUS IO Link AS Interface Field level PROFINET With 4.3 million nodes installed, PROFINET is the world's leading Ethernet standard for automation. The forecast annual growth of more than 30% emphasizes the strong position. Company-wide automation with PROFINET: PROFINET – the open Industrial Ethernet Standard for automation – ensures integrated communication. Existing fieldbus systems can be easily integrated. This protects your investments for the future. With PROFINET, the established IT services (e.g. web services, remote services, TCP/IP communication) can be used easily. PROFINET offers innovative diagnostics options, new functions such as Shared Service, I-Device, MRP (Media Redundancy Protocol), and high performance. This enables new, user-friendly applications, such as wireless, high-precision automation with Industrial Wireless LAN – now also in process automation. PROFIBUS PROFIBUS is the No. 1 fieldbus – the proof lies in the 40.1 million nodes installed worldwide. PROFIBUS is not only implemented in the manufacturing area, but it can also be used throughout the process industry – even in hazardous areas. Standard interfaces support quick and easy connection of the I/O to your systems and therefore integrated communication from the cell level down to the field level. AS-Interface AS-Interface is an open, standardized bus system that enables simple integration of actuators and sensors at the lowest field level. IO-Link IO-Link is the smart concept for the standardized linking of sensors and switching devices to the control level by means of an economical point-to-point connection. This new communications standard below the fieldbus level allows central fault diagnosis and location as far as the sensor/actuator level and simplifies commissioning and maintenance by allowing the parameter data to be modified dynamically, direct from the application. Distributed automation 9 © Siemens AG 2012 Product range at a glance Solutions in a control cabinet (IP20) 1) SIMATIC ET 200SP – The scalable I/O with outstanding user-friendliness 1) ■ ■ ■ ■ ■ ■ ■ ■ Adjustable connection of the PROFINET interface via bus adapter Individual load groups can be formed without separate feeder module System construction with permanent wiring, hot swapping and operation with rack gaps Extensive diagnostics Space-saving push-in terminals for one-handed wiring without any tools and self-holding measuring probe Simple disconnection of wiring thanks to arrangement of wire insertion, spring opener and measuring probe in columns Terminals for single- or multi-conductor connection Meaningful color-coding and labeling concept SIMATIC ET 200S – the all-rounder with a comprehensive range of functions 1) ■ ■ ■ ■ ■ Discretely modular configuration with multi-conductor connection Multifunctional thanks to a wide range of modules: motor starters, safety technology, technology modules, distributed intelligence, as well as IO-Link modules Use in hazardous area (Zone 2) Also available as a high-speed (HS) version for high performance and maximum precision Also available as expandable block version with integral DI/DO: SIMATIC ET 200S COMPACT N SIMATIC ET 200MP – The multi-channel and multi-functional S7-1500 I/O ■ ■ ■ ■ ■ High performance and very short response times for high-speed applications Scalable design with 35 mm wide modules Standardized pinning of the modules and cable storage space that grows with the system Versatile labeling options for better identification Standardized diagnostics and display concept SIMATIC ET 200M – the multi-channel S7-300 1) ■ ■ ■ ■ ■ Modular design using standard SIMATIC S7-300 modules; redundant design also possible Fail-safe I/O modules High channel density with up to 64 channels per module For use in hazardous areas up to Zone 2, sensors and actuators up to Zone 1. High plant availability thanks to redundancy, hot swapping, and configuration changes during operation SIMATIC ET 200iSP – the intrinsically-safe version for hazardous areas ■ ■ ■ ■ ■ Modular design, also available with redundancy Rugged, intrinsically-safe design Fail-safe I/O modules Use in hazardous areas up to Zone 1/21, sensors and actuators may even be located in Zone 0/20 High plant availability thanks to redundancy, hot swapping, and configuration changes during operation 1) available as SIPLUS extreme in refined version for extreme environmental conditions. 10 Product range at a glance © Siemens AG 2012 Solutions without a control cabinet (IP65/67) SIMATIC ET 200pro – modular and multifunctional ■ ■ ■ ■ ■ Modular design with an extremely compact enclosure Easy installation Multi-functional thanks to a wide range of modules – from simple inputs and outputs through safety systems, motor starters and frequency converters, to identification systems High plant availability thanks to hot swapping and permanent wiring Extensive diagnostics SIMATIC ET 200eco PN – Block I/O with PROFINET connection ■ ■ ■ ■ ■ Low-cost, space-saving block I/Os Digital modules with up to 16 channels (can also be parameterized) Analog modules, IO-Link Master and load voltage distributor PROFINET connection with 2-port switch in each module Can be flexibly distributed in the plant via PROFINET in a line and/or star topology SIMATIC ET 200eco – digital block I/O ■ ■ ■ ■ Low-cost digital block I/O Flexible connection options Fail-safe modules High plant availability – the electronic block can be easily replaced during operation without any interruption in bus communication or power supply Product range at a glance 11 © Siemens AG 2012 Product overview ■ SIMATIC ET 200 for the control cabinet I/O system N ET 200SP ET 200S ET 200MP ET 200M Degree of protection Construction type IP20 Discretely scalable IP20 Modular IP20 Modular Mounting Connection system for sensors/ actuators DIN rail Single or multi-conductor connection Push-in terminal IP20 Bit-modular, expandable block DIN rail Single- or multi-conductor connection Spring-loaded/screwtype, Fast Connect S7-1500 mounting rail Single-conductor connection Screw-type, push-in-terminal S7-300 mounting rail Single-conductor connection Spring-loaded/screwtype, Fast Connect, Top Connect n (available soon) n n (available soon) n Zones 2, 22 Zones 2, 22 Zones 2, 22 - - - 0 °C … +60 °C (horizontal mounting) 1) to 5 g 4) 0 °C … +60 °C 1) 2g 0 °C … +60 °C (horizontal mounting) 2g Zones 2, 22 Switched, redundant 0 °C … +60 °C 1) n / n (available soon) n/n Configuration Special applications Safety technology For use in hazardous areas Increased availability Temperature range Vibration resistance (continuous) 1g Communication PROFINET (copper/fiber-optic) PROFIBUS (copper/fiber-optic) AS-Interface Other n/- n/- n (avail soon)/(avail soon) 12 Mbit/s / 12 Mbit/s n (available soon) / - 12 Mbit/s / - n - - - - n 8) - - n n n Front connector n Front connector n/n n 6) / n 6) n (available soon) / - n 8) / n 8) n n n n n n n (available soon) n n n n n Submodule-specific Channel-specific (chan.-spec. avail. soon) Channel-specific Channel-specific Digital channels Analog channels incl. HART Motor starters / frequency converters Pneumatic interface Technological functions n n n n n - n n - n n -/- n/- -/- -/- n (available soon) n 2) - - n Counting/measuring, positioning, weighing n Integrated CPU functionality/ I-Device Shared device 3) MRP 3) Options handling Sensors and actuators (IO-Link) n (available soon)/ n (available soon) n/n -/- Counting/measuring, positioning, cam ctrl, closedloop ctrl, weighing n / n (via S7-300 CPUs) n n n n n n n n 5) n n (available soon) - n n - - n can be used / available - cannot be used / not available 1) Also available as SIPLUS component for extended temperature range -40 °C … 70 °C and corrosive atmosphere/condensation (for details, see: www.siemens.com/siplus-extreme) 2) System functions Permanent wiring Hot swapping / operation with gaps Isochronous mode, e.g. for high-speed controls Re-configuration during operation High-speed modules Diagnostics (module-dependent) Functions 12 Product overview 3) 4) You can find additional information on the supplemental products at: www.s ie mens .c om/ si ma ti c- et2 00 Available for PROFINET versions With bus adapter BA2 x FC 5) 6) 7) 8) n Configuration control via user program With reserve modules Communication module CANopen, DeviceNet With active backplane bus © Siemens AG 2012 ■ SIMATIC ET 200 without control cabinet ET 200iSP ET 200pro ET 200eco PN ET 200eco I/O system IP30 Modular IP65/66/67 Modular IP65/66/67 Block IP65/66/67 Block Degree of protection Construction type Mounting rail Multi-conductor connection Spring-loaded/ screw-type Mounting rail M8, M12, M23 Direct mounting M12 Direct mounting M12 Mounting Connection system for sensors/actuators n n - n Zone 1, 21 Switched, redundant -20 °C to +70 °C - - - - - - -40 °C … +60 °C 0 °C to +55 °C 1g -25 °C ... +55 °C (0 °C ... +55 °C) 9) 5 g (mod.-dependent) Safety technology For use in hazardous areas Increased availability Temperature range 20 g 5g Vibration resistance (continuous) - n/- -/- 1.5 Mbit/s / - 12 Mbit/s / 12 Mbit/s 1 n/- - - - - - - - - n n - - n 6) / n 6) - n/- -/- -/- n n - - - - - - Channel-specific Channel-specific Channel-specific Submodule-specific n n n n n n - n 10) n - -/- n/n n 2) n 2) -/- -/- Counting, frequency measuring - - - Digital channels Analog channels incl. HART Motor starters / frequency converters Pneumatic interface Technological functions -/- n/n -/- -/- Integrated CPU functionality/I-Device - n - - - n n - - n - - - - n - Shared device 11) MRP 11) Options handling Sensors and actuators (IO-Link) Design Special applications Communication 12 Mbit/s / - PROFINET (copper/fiber-optic) PROFIBUS (copper/fiber-optic) AS-Interface Other System functions Permanent wiring Hot swapping / operation with gaps Isochronous mode, e.g. for high-speed controls Re-configuration during operation High-speed modules Diagnostics (module-dependent) Functions 9) In parentheses: Temperature range of the frequency converter 10) Also configurable 11) Available - n can be used / available - cannot be used / not available for PROFINET versions Product overview 13 © Siemens AG 2012 ET 200 - characteristics Simple configuration and increased plant availability Simple configuration Integral plug-in connections make installation quick and easy and therefore reduce the costs. In the case of modular systems, mounting is on a rail. The modules are snapped onto the rail and plugged into each other. The sensors and actuators can be easily connected to a bus system without the need to use an array of single wires with cable distributors and cable racks. This makes the wiring simple and transparent, less error-prone and therefore low-cost. Self-assembling backplane bus Permanent wiring Due to the separation of mechanics and electronics, permanent wiring is possible, i.e. the station can be prewired before installation or start-up. Prewiring can therefore be inspected without the electronics modules which prevents damage to sensitive components. The start-up time is therefore reduced. In addition, the modules can also be replaced in the event of a fault without time-consuming rewiring. Permanent wiring: Connections and electronics are separate from one another Hot swapping In the event of a fault, electronic modules are easily replaced during operation with the equipment live (hot swapping). The station remains functional, and the plant therefore remains available – there is no need for costly shutting down and starting up of the plant. While the components are being replaced, the wiring remains intact. Hot swapping: Module replacement during operation Configuration in Run (CiR) Changes or expansions are required even during active operation of a (sub-) system. Possible applications are due to nonstop requirements, that is, in continuous processes in process engineering that cannot be shut down or whose production cannot be interrupted. Changes to the hardware configuration in RUN are possible when distributed I/Os are connected to the S7-400: • Stations can be added and removed, e.g. for configuring a new process line • I/O modules can be added and removed, e.g. for implementing additional sensors • I/O modules can be reparameterized, e.g. for replacement parts 14 ET 200 - characteristics Changes to the configuration are possible during normal operation © Siemens AG 2012 Use in hazardous areas In many industries, the manufacture, processing, transport or storage of combustible materials results in the creation or release of gases, vapors or mist into the environment. Other processes create combustible dust. In combination with oxygen in the air, a potentially explosive atmosphere can occur that will result in an explosion if ignited. Special properties must be exhibited by the equipment used in these environments, and they must be certified. SIMATIC ET 200 is equipped for this, and includes a corresponding range of products. The ET 200 systems can be used in different zones – either in Zones 2 and 1 in the case of gaseous atmospheres, or in Zones 22 and 21 in the case of dusty atmospheres. The sensors and actuators linked to the I/Os can even be in Zone 0 or Zone 20. A manufacturer's declaration (compliance of the control cabinet with the ATEX directive) is necessary for installation in Zone 2/22. Certification of the control cabinet for the gas/dust area must be procured for installation in Zone 1/21. Data communication takes place as usual over PROFIBUS. If communication is continued over PROFIBUS stations in Zone 1 or for other reasons over intrinsically safe PROFIBUS stations, the PROFIBUS is made intrinsically safe by an intermediate fieldbus isolating transformer. This limits the ignition energy to the permissible level and the intrinsically safe PROFIBUS is routed to the hazardous area. Control system Industrial Ethernet Class I Zone 1 ATEX Zone 2 Zone 1 Zone 0 Class II Zone 1 Class II Zone 0 FM/UL Class II Zone 2 ATEX Zone 22 Zone 21 1) Ex isolating transformer 1) ET 200M ET 200iSP Ex i, Ex e ET 200 in hazardous gas and dust atmospheres Ex i Actuators/ sensors HART PROFIBUS PA SITRANS F 1) 3) PROFIBUS DP-iS Fieldbus isolating transformer 1) Actuators/ sensors Actuators/ sensors HART 1) DP/PALink Zone 20 Hazardous area Actuators/ sensors S7-400 Class I Zone 0 2 10 ET 200S 2) Class I Zone 2 SITRANS P AFDiS Actuators/ sensors G_ST70_XX_00674 DUST FM/UL 1) Gas atmosphere: Installation of the components always in an enclosure in Zone 2 in degree of protection IP5x and in Zone 1 in an Ex e enclosure. Dust atmosphere: Installation of the components always in an enclosure in Zone 22 with IP5x degree of protection and in Zone 21 with IP6x degree or protection. 2) With 10 A DC standard power supply 3) Installation of the station complies with FM/UL up to Class I, Division 2; connected sensors and actuators even up to Class I, Division 1 or installation of station and sensors/actuators according to FM/UL up to Class II/III, Division 1 ET 200 - characteristics 15 © Siemens AG 2012 PROFINET innovations PROFINET has been expanded by a number of innovative features. These simplify system configuration in fail-safe applications, for example, and they allow a leaner and more versatile topology in many different scenarios. The Shared Device function enables two controllers to access the same PROFINET IO device, for example a distributed ET 200 station. Since fewer remote devices have to be installed in the field, the engineering, wiring and installation costs can be reduced. In addition, the modules can be flexibly assigned to one of the two CPUs. SIMATIC ET 200pro SIMATIC S7-300 SIMATIC S7-400 Ring (MRP) PROFINET IO-Controller 1 IO-Controller 2 SIMATIC ET 200SP Industrial Ethernet Ring topology with Media Redundancy Protocol (MRP) Higher plant availability can be achieved using a ring topology and the Media Redundancy Protocol (MRP). This runs direct via the integral PROFINET port to SIMATIC controllers and ET 200 IO stations and can be used with or without IE switches. PROFINET Industrial Ethernet IO-Device With the Shared Device function, two different IO controllers can access the same IO device simultaneously The I-Device (intelligent IO device) function enables simple and fast controller-controller communication through direct access to the IO address image with the PROFINET IO protocol.Local controllers, such as the ET 200S CPU, can be more easily integrated into modular machines or safety applications, for example. PROFINET systems with the innovative PROFIenergy profile are able to control power consumption. They can be configured in such a way that they can be disconnected automatically and in a coordinated way during breaks in production, and then connected again when production starts up again – in the correct order, at the correct intervals, reliably and plantwide. 16 ET 200 - characteristics Additional expanded functions The ET 200S supports the Options handling function. With this, an application can be subdivided into several modules or sub-tasks (e.g. bottling, labeling, packaging), without the need to manage several projects for different machine constellations. In the ET 200S station, the input/output modules are assigned to the appropriate sub-tasks. The actually available machine modules or the input/output modules of the ET 200 station required for this are selected and activated at commissioning. PROFINET IRT allows high-speed and deterministic communication in which the different cycles of a system (input, remote station, network, CPU processing and output) are synchronized even in the case of parallel TCP/IP traffic. High-precision and dynamic applications can thus be implemented using SIMATIC. © Siemens AG 2012 Configurator (selection tool) Just a mouse click away from a tailor-made I/O station With the Configurator, you get first class support with assembling your overall automation system (SIMATIC S7, ET 200 station). The software tool guides you comfortably, easily and conveniently through the configuration and creates automatic ordering lists for you including accessories. It also supports you with compliance with limitations, for example, for load currents, slot rules or parameters. The configuration generated can be imported easily into STEP 7. This reduces the engineering overhead and avoids double entries. The software tool is structured clearly: Six configuration views make working easy and convenient: • General: General station data as well as a graphical presentation of the configured station • Module selection: Guided selection of modules by means of module suggestions • Limits: Display of station size, weight, number of modules, load voltage, parameters, etc. • Accessories: Guided selection of the required accessories (module-specific or station-wide) • Potential distribution: Graphical presentation of the potentials within a station • Parts list: Automatic generation of a transparent parts list makes ordering easier You can find the field-proven ET 200S, ET 200M, ET 200iSP, ET 200pro, ET 200ecoPN and ET 200eco devices in the SIMATIC Selection Tool. You can configure the new ET 200SP in the TIA Selection Tool. Standards and approvals Standards and approvals PROFIBUS EN 50 170, Volume 2 PROFINET IEC 61158 IEC 1131 IEC 1131, Part 2 UL Acc. to UL508 standard, File No. E 116536/E 75310 (AC modules) CSA Acc. to standard C22.2 No. 142. File No. LR 48323/LR 44226 (AC modules) cULus (for hazardous locations) Acc. to UL 508 standard File no. E 116536 acc. to hazardous locations UL 1604 File no. E 222109 acc. to CSA C22.2 standard No. 142 FM Standard Class No. 3611, Class I Div. 2, Group A, B, C, D Class I, Zone 2, Group IIC (without motor starter) Shipbuilding American Bureau of Shipping Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyds Register of Shipping Nippon Kaiji Kyokai Ex approval Cat. 3 (for Zone 2 acc. to ATEX-100a) EN 50 021 ISA ISA-S71.04 Severity Level G1, G2, G3 (for ET 200S, ET 200M, ET 200iSP) Safety IEC 62061 up to SIL3, EN ISO 13849-1 up to PLe, as well as EN 954-1 up to Cat. 4 Corrosive gas resistance (in SIPLUS extreme version) EN 60721-3-3 for classes 3C4, 3B2 and 3S4 Salt fog test (in SIPLUS extreme version) According to EN 60068-2-52 CAx data "CAx data" (product data, graphics, manuals) are available for our ET 200 systems as free downloads via the CAx online shopping cart: Configuration made easy with the TIA Selection Tool You can find the Configurator on the Internet at: www.siemens.com/et200 www.siemens.com/tia-selection-tool or in the Industry Mall and also in the Catalog CA01 on DVD www.siemens.com/cax Configuration engineers, electrical planning engineers, and commissioning engineers with CAE systems such as EPLAN Electric P8, can use such CAx data for quick and easy creation of, for example, electrical circuit diagrams, installation diagrams, and parts lists, as well as for wiring and servicing the control cabinet. In this way, the best possible support is provided for the customer's project - from product selection, through electronic CAx data provision, right up to generating CAE/CAD documentation. ET 200 - characteristics 17 © Siemens AG 2012 SIMATIC ET 200SP The scalable I/O with excellent ease of use The ET 200SP is about 50% narrower than comparable distributed I/O systems. This means up to 64 modules with a maximum of 16 signals each can be set up depending on the interface module used. Thanks to the newly developed connection system, the height for the terminals has been significantly reduced and thus the overall height of the system, even with double the number of terminals: • With a height of around 117 millimeters, the system provides space for 16 channels with a single-conductor connection (without AUX terminals). • For a 3-wire connection with AUX-terminals, the height is 141 millimeters for 8 channels. • The depth is about 75 millimeters. SIMATIC ET 200SP* (Scalable Peripherals) is the universal I/O system with IP20 degree of protection for installation in the control cabinet. Its wide area of application ranges from standard mechanical equipment manufacture, through highspeed applications (available soon), up to plant building. The ET 200SP is particularly easy to use, ensures maximum economy in the control cabinet with its compact design, and offers high performance. Compact design The ET 200SP makes optimal use of the available space in the control cabinet. The compact design is achieved by increasing the number of channels per module. The station width is reduced by one slot per potential group because the power module for feeding in the supply voltage is already integrated into the system. An ET 200SP station consists of an interface module (IM) for connecting to PROFINET, the I/O modules and a server module that terminates the station: • The modules are plugged into passive BaseUnits (BUs) that are in turn mounted on a standard DIN rail. The BaseUnits (BUs) connect the modules of the ET 200SP station electrically and mechanically with each other. The terminal box of a BaseUnit can be simply replaced in the case of terminal damage, for example. • The PROFINET connection is via bus adapters (BAs) on the IM with which the connections and physical characteristics can be selected freely in accordance with requirements, e.g. RJ45 connector or direct connection (FastConnect). • The I/O modules define the function of the module at the terminals and are subdivided into seven module types. These are each labeled on the front with a colored square specific to the module type. The mechanical coding of the I/O modules with the BaseUnit prevents mix-up of the modules during installation. To achieve simple load shutdown, individual potential groups can be formed. * 18 SIMATIC ET 200SP Now also available as SIPLUS extreme version for use under extreme environmental conditions. © Siemens AG 2012 Wiring Labeling The separation of mechanical and electronic components permits permanent wiring. In addition, it is possible to pre-wire the BaseUnits on the standard DIN mounting rail. A well thought-out labeling system ensures clear and proper presentation of the ET 200SP station. This allows the modules as well as the terminal boxes to be replaced during operation (hot swapping). • Order number and version release of the hardware and firmware are printed. • The I/O modules are color-coded depending on type. • The terminal connection diagram helps with fast and errorfree replacement of connected devices. • A 2D matrix code is printed on the front. It specifies the order number and the serial number. This makes it possible to conduct an automated comparison between projected and actual station layout. The barcode also allows you to link to other information (e.g. manuals, firmware, certificates) via a smartphone application. The following labels are found at the factory: The new arrangement of the terminals and the push-in terminals makes wiring and disconnection of the cables faster and simpler than ever. Wiring is carried out without tools, using one hand, and with very low insertion force. Despite this, the connections have an extremely high mechanical load capacity. Only a screwdriver is required for disconnecting the cables. The following labels are possible on the user side: • The system components can be labeled using clip-on identification tags. • Individually printable, generous labeling strips allow description of the signals applied to the terminal. • Color coding labels identify the potentials of an I/O module and simply assignment of the cables. The shielding concept covers the conductor, the terminal box, the backplane bus, and the PROFINET cable. It ensures the greatest possible electromagnetic compatibility (EMC) and increases the signal quality. SIMATIC ET 200SP 19 © Siemens AG 2012 Communication The ET 200SP communicates via PROFINET, the global Ethernet standard in automation. The I/O system is dimensioned for a maximum internal data transfer rate of 100 Mbit/s. This is the first I/O system in which the internal communication cycle synchronizes automatically, and without configuring overhead, to the set PROFINET bus clock. This significantly reduces undesirable response time fluctuations, and makes more accurate positioning or closed-loop control possible, for example. One special feature of the F-modules of SIMATIC ET 200SP is that the F-addresses no longer have to be set manually by means of the DIL switches on the module. Instead, they are now assigned with the engineering tool during commissioning, which simplifies the setting process and saves time. Engineering The ET 200SP is configured with the TIA Portal from V11, SP2 or STEP 7 from V5.5, SP2. Diagnostics In IRT (isochronous real-time) mode, there is system-wide synchronization from the user software to the terminal. The input data of all stations is acquired synchronously and offset-free, and the output data is then also output synchronously and offset-free. The interface module of the SIMATIC ET 200SP will also be available with a PROFIBUS interface – the tried-and-tested communication standard proven in numerous applications. ET 200SP increases energy efficiency in the automation system with PROFIenergy by shutting down the loads during breaks in a controlled manner, module-by-module or channelby-channel (available soon), thus reducing energy consumption. PROFIenergy also uses parameterizable break-time substitute values for inputs and outputs. Safety Integrated SIMATIC ET 200SP also permits safety-related communication. The digital safety modules are exactly as compact as the standard modules. Their functional safety is certified in accordance with EN 61508. They are designed for safety-related use up to SIL3 according to EN 62061 and PL e according to ISO 13849. 20 SIMATIC ET 200SP Extensive diagnostics functions simplify monitoring and maintenance. The digital modules of the function class "Standard" already offer wirebreak and short-circuit diagnostics. Diagnostics takes place via LEDs on the I/O module. In addition, SIMATIC ET 200SP features an easily accessible, self-holding measuring probe. It remains inserted in the device and permits "multi-connection" (simultaneous existence of several measuring probes). Other system functions include: • Multi hot swapping: Modules can be replaced during operation • "Reset to factory" settings of the interface module via pushbutton • Dynamic reparameterization of the I/O modules during operation • Configuration of the ET 200SP station controlled via the user program, e.g. adaptation of the configuration to the actual machine (option handling) and partial commissioning • Firmware update for functional expansion of the interface module and the I/O modules without module replacement • Electronic rating plate (identification data) for unique identification of the relevant module for test or quality assurance purposes © Siemens AG 2012 Interface modules Communication modules The interface module connects the ET 200SP to PROFINET and exchanges data between the higher-level controller and the I/O modules. The variable bus adapter (BA) is simply plugged into the interface module and enables free selection of the connection system: There will also be an AS-Interface master communication module. This AS-i master makes it possible to connect simple field devices via AS-Interface to the ET 200SP. The AS-i master is characterized by an extremely small size, meets specification V3.0, and enables connection of up to 62 nodes. • IM 155-6PN Standard incl. server module 6ES7 155-6AU00-0BN0 • IM 155-6PN Standard incl. server module and mounted bus adapter 2xRJ45 6ES7 155-6AA00-0BN0 SIPLUS versions The interface modules and the I/O modules listed below are also available as SIPLUS components for the extended temperature range of -40 to +70°C and corrosive atmosphere / condensation. (For details, visit: www.siemens.com/siplus-extreme) I/O modules The I/O modules are 1-, 2-, 4-, 8- and 16-channel, and they permit scalable and cost-optimized design of the ET 200SP. Digital and analog input/output modules are available: Function Order No. group Digital input DI 8x24 V DC Standard 6ES7 131-6BF. Digital input DI 16x24 V DC Standard 6ES7 131-6BH. Digital output DQ 4x24V DC/2A Standard 6ES7 132-6BD. Digital output DQ 8x24V DC/0.5A Standard 6ES7 132-6BF. Digital output DQ 16x24V DC/0.5A Standard 6ES7 132-6BH. Function Order no. group Analog input AI 4xI 2-/4-wire Standard 6ES7 134-6GD. Analog input AI 4xU/I 2-wire Standard 6ES7 134-6HD. Analog input AI 4xRTD/TC 2-/3-/4-wire, high-feature 6ES7 134-6JD. Analog output AQ 4xU/I Standard 6ES7 135-6HD. In order to expand the AS-i network with safety-oriented communication (ASIsafe), the AS-i safety module can be inserted in addition to the AS-i master without any additional wiring. This means that as many as 31 safety-related sensors and actuators are possible in each AS-i network (SIL3 according to EN 62061 and PL e according to ISO 13849). The new IO-Link master module of SIMATIC ET 200SP integrates the fast and simple IO-Link communication with sensors and actuators into the established PROFINET or PROFIBUS field bus system. The new IO-Link master is based on the current IO-Link specification V1.1. and allows not only the IO-Link device parameters, but also the master parameters to be stored consistently. This means that when a device is replaced, the current parameters are automatically transferred into the replaced IO-Link device – without any additional effort by the user. In addition, a replacement of the master module is possible without PG/PC and without the data being restored by the user. Moreover, the IO-Link master offers shorter response times, thanks to support of COM3. It goes without saying that IO-Link devices according to specification V1.0 continue to be supported. The TIA Selection Tool can be found on the Internet at www.siemens.com/tia-selection-tool or in the Industry Mall and also in the Catalog CA01 on DVD SIMATIC ET 200SP 21 © Siemens AG 2012 SIMATIC ET 200S The all-rounder with the comprehensive range of modules SIMATIC ET 200S is the multifunctional, highly modular I/O system with IP20 degree of protection that can be exactly tailored to the automation task. Thanks to its rugged construction, it can also be used under conditions of high mechanical stress. Various interface modules are available for interfacing to the PROFINET and/or PROFIBUS bus systems. Interface modules with an integral CPU transfer the computing power of an S7-300 CPU directly into the I/O device and constitute a local controller. They therefore offload the central PLC, and permit rapid responses to time-critical signals. Interface modules with integrated CPU and PROFINET/ PROFIBUS connection are available – both in standard and safety-related designs. The PROFINET version of the ET 200S also offers the following new functions: • I-Device • Shared device • MRP New high feature interface modules, fast I/O modules, isochronous mode and an extremely fast internal data transport increase the performance of the ET 200S and permits the use even with extremely fast closed-loop controls. With the 8-channel digital input and output modules, the bitmodular ET 200S is even more compact. They are perfectly suited for configurations with many channels and a space-saving and cost-saving configuration is demanded. The 8-channel module permits the connection of 2-wire sensors and they offer a simultaneity factor of 100% (that is, 4 A summation current with 8 outputs with 0.5 A each). Distributed automation solutions increasingly involve not just digital and analog signals, but also technological functions, motor starters, or a pneumatics connection. The bit-modular ET 200S offers a comprehensive module range to implement the tasks: • Technology modules are available e.g. for counting and positioning tasks, for cam control or for closed-loop control tasks. • Using the motor starters/soft starters, any three-phase loads up to 7.5 kW can be connected. Motor starters are available in several designs, including a fail-safe design. • The motor starters have the PROFIenergy function and support acyclic services. Acyclic services permit the sending and receiving of data sets, e.g. for precise diagnostics and parameterization during operation. 22 SIMATIC ET 200S ET 200S with PROFINET connection, I/O modules, and motor starters • Pneumatic connection using modules from Bürkert • I/O-Link modules support the connection of intelligent sensors such as non-contact sonar proximity switches. • CANopen module from HMS • PROFIenergy power modules and High Feature motor starters • Failsafe I/O modules permit the integration in safetyrelated plants with SIMATIC Safety Integrated. • SIPLUS components also allow for operation in the extended temperature range -40 °C ... +70 °C and in corrosive atmospheres or under condensation conditions (For details, visit: www.siemens.com/siplus-extreme) Diagnostics functions and hot swapping of modules increase plant availability: • Comprehensive diagnostic interrupts indicate the module status on the one hand and channel-specific information on the other hand. • Electronic modules and motor starters can be replaced while connected to power during normal operation and without the need for tools (hot swapping). During replacement of a module, the SIMATIC ET 200S can continue to operate and the application will continue to function properly. If motor starters are used, the otherwise obligatory system isolation can even be avoided. The SIMATIC Selection Tool can be found on the Internet at www.siemens.com/et200 or in the Industry Mall and also in the Catalog CA01 on DVD © Siemens AG 2012 Bit-modular economical design with multi-conductor connection In addition to the extremely low space requirements, the ET 200S results in savings in wiring of up to 80% in comparison to conventional solutions. The reasons for this are: • The backplane bus is built up automatically. • All supply terminals have the characteristics of terminal blocks, allowing signal leads and motor cables to be directly connected to the SIMATIC ET 200S without the need for intermediate terminals. • The integral safety system is a system component – an additional safety bus can therefore be omitted. • Reserve modules can be used to reserve module slots for future use. • Permanent wiring • Considerably less cross-wiring thanks to the self-assembling voltage busses – this reduces the testing outlay and possible sources of error. • The module labeling is not covered by the wiring when the module is installed. • Easy configuration of an ET 200S station with the SIMATIC Selection Tool Power module PM-E Electronic module Fast Connect The insulation displacement method Fast Connect offers even more benefits for installation of the electronic and power modules. With this new method, the standard conductor crosssections from 0.34 to 1.5 mm² can be connected. No preparation is required for installation: • Time savings of up to 60 % for installation as compared to the conventional Fast connection system connection methods • No stripping or crimping necessary • Simple and safe installation with a screwdriver. Reduction of error ratio during installation • The stripped length does not have to be determined Power module PM-D Motor starter Bus termination module Terminal modules Terminal module TM-D with integrated energy bus PE/N module G_PCS7_XX_00197 Interface module IM 151 Bit-modular design of ET 200S SIMATIC ET 200S 23 © Siemens AG 2012 Interface modules for bus connection ET 200S is connected to the bus system via the interface module – either to the field-proven PROFIBUS or to PROFINET, the open Industrial Ethernet standard. Various interface modules can be chosen, which all provide for channel-specific diagnostics: IM 151-3 PN HS PROFIBUS Copper Copper/FOC1) Copper - - - PROFINET - - - Copper Copper/FOC1) Copper 6) - - - n n n Number of modules 12 63 63 63 63 32 Station width 2m 1 m/2 m 2m 2m 2m 0.5 m Fail-safety - - n - n - Isochronous mode - - n - - n 6) PROFIenergy - - - - n/- - Shared device - - - n n n MRP - - - n n/- - Electronic rating plate 2) - n n n n n Firmware update - Bus n Bus/Micro Memory Card Bus/Micro Memory Card Order No. group 6ES7 151- 1CA. 1AA. / 1AB. 1BA. 3AA. 3BA. Bus/Micro Interface module IM 151-3 PN FO Memory Card with fiber optic cable 3BA6-. 2-port switch 4) IM 151-8F5) PN/DP CPU IM 151-85) PN/DP CPU IM 151-75) F-CPU IM 151-7 CPU/ CPU FO5) Interface modules with CPU functionality3) PROFIBUS Copper/FOC1) Copper n 3) n 3) PROFINET - - Copper Copper 2-port switch 4) - - n 7) n 7) Number of modules 63 63 63 63 Station width 2m 2m 2m 2m Fail-safety - n - n Isochronous mode - - - - PROFIenergy - - n - I-Device - - n n Shared device - - n n MRP - - n n Electronic rating plate 2) - - n n Firmware update Micro Memory Card Micro Memory Card Bus, Micro Memory Card Bus, Micro Memory Card Order No. group 6ES7 151- 7AA. / 7AB. 7FA. 8AB. 8FB. n can be used / available - cannot be used / not available 24 IM 151-3 PN HF 5) IM 151-3 PN FO IM 151-3 PN 5) IM 151-1 5) High Feature (HF) IM 151-1 5) Standard/ Standard FO IM 151-1 BASIC IM 151-1 COMPACT Interface modules without CPU functionality SIMATIC ET 200S Interface module IM 151-3 PN HF for PROFINET with standard cable 1) Plastic, polymer-cladded fiber (PCF) 2) The electronic rating plate contains identification data saved in a module, e.g. order number, product version, installation date, plant identification, which unequivocally identify the module and are available online, to simplify troubleshooting, for example. 3) Additional PROFIBUS line with master module 6ES7 138-4HA. 4) The integral 2-port switch of the IM 151-3 now also easily permits a linear structure in addition to the star topology. 5) Also available as a SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (for details, see www.siemens.com/siplus-extreme). 6) Available with SIMOTION controller as of V4.1 SP1 and PROFINET with IRT. 7) 3 port-switch © Siemens AG 2012 Distributed intelligence The interface modules with integrated CPU can be used both in stand-alone mode and for distributed automation solutions with a medium-sized program. They correspond to a CPU 314 and enable distributed preprocessing of the production data locally – even in the failsafe version. IM151-8 PN/DP CPU Depending on the version, communication can take place via MPI/PROFIBUS and/or PROFINET. This has the following advantages: • Relieves the central control unit • Reduction in the response times to critical local signals • More transparent and shorter programs • Easier trouble-shooting • Less load on the bus system • Modularization of the system structure and precommissioning – also at different sites Additional PROFIBUS line The DP master module for the interface module with integrated CPU is used to expand the ET 200S as master with an integrated DP master interface. A lower-level PROFIBUS line can then be configured with Interface module IM 151-7: with further distributed I/O. Options handling Options handling is available for interface modules with PROFINET interface and for those with PROFIBUS interface. SIMATIC ET 200S COMPACT – The block I/O featuring bit-modular expansion SIMATIC ET 200S COMPACT is the new interface for the bitmodular ET 200S I/O system. The new IM 151-1 COMPACT interface module expands the well-known range of proven ET 200S modules and permits use as a block I/O. The functionality is based on the IM 151-1 BASIC and ET 200S COMPACT comprises an interface modexpandable block ule and 32 channels in one block. Two different variants of the ET 200S COMPACT are offered – either a station with 32 digital inputs or mixed with 16 digital inputs and 16 digital outputs. By expanding the block with ET 200S modules (up to 12 modules), a total of 128 channels can be connected to the SIMATIC ET 200S COMPACT. This means that frequently required inputs/outputs in block form can be combined with bit-modular specialist modules such as motor starters, pneumatics, etc. Expansions with the 8-channel modules support an extremely high packing density. As a result, one terminal box can accommodate more components or a smaller terminal box can be used. integral CPU (also as F version) and master module With the use of options handling with SIMATIC ET 200S, the entire station including all options is configured. Modules for unnecessary options are either replaced by reserve modules or can be completely eliminated. Optional functions are activated during operation without new configuration. ET 200S COMPACT with expansions Options handling is available in two versions: With reserve modules In this case, the station is configured with all options. I/O modules that are not required are replaced by cost-effective reserve modules. Later, they can be exchanged for the configured modules without new configuration, even during ongoing operation. Without reserve modules In this case, the station is configured with all options, however, only the necessary modules (terminal and I/O modules) are plugged in. The modules which are not plugged in can be later retrofitted as required without new configuration. SIMATIC ET 200S 25 © Siemens AG 2012 Motor starters for any application The ET 200S motor starters can be used to protect and switch any three-phase load. The completely prewired devices are available in different performance classes as direct, reversing or soft-starters up to an output of 7.5 kW. The terminal module contains the self-assembling energy bus and the terminals for direct connection of the motor cable. A motor starter can be removed and inserted without the need to isolate the system. Standard motor starters • • • • Circuit-breaker and contactor combination up to 5.5 kW Direct-on-line or reversing starters Optional safety system PCS7 faceplates for visualizing diagnostics data High Feature motor starters • Combination of starter circuit-breaker, electronic overload protection and contactor or soft starter up to 7.5 kW • PROFIenergy functionality for selective shutdown of motors during breaks, and reading out the motor current • PCS7 faceplates for visualizing diagnostics data • Statistical data, e.g. current for the last overload trip, can be read out using the service and commissioning software Motorstarter ES • Parameterization via bus, and sending and receiving of acyclic data via the fieldbus • Only two current setting ranges up to 7.5 kW • Safety technology integrated Fail-safe motor starter As soon as more complex or widely distributed safety applications are implemented, the Failsafe motor starter in combination with the PM-D F PROFIsafe power module is the optimized solution. Signals from safe sensors are read in through safe inputs at any required point in a plant and transferred to the failsafe controller via PROFIBUS by means of the PROFIsafe message frame. In the application program they are linked to the Failsafe motor starters or the associated power module. The failsafe motor starter has been developed on the basis of the High Feature motor starter. It offers the following innovative, patented technology: In normal operation, the contactor shuts down the circuit breaker; in the event of a fault, this is handled by the integral dual-processor monitoring. This makes shutdown possible even if a contactor has a welded contact. It also ensures that each individual motor starter achieves SIL 3 or Category 4 without additional redundancy contactors. 26 SIMATIC ET 200S The fail-safe motor starter monitors the function of the contactor regardless of whether the application is safety-related or not, so these devices are also suitable for use in high-availability processes. Further characteristics that support high availability are: Motor starter for failsafe ET 200S • Type of coordination 2 over the complete power range up to 7.5 kW • The emergency start function allows important processes to be continued to completion despite a reason for shutdown, e.g. overload. Advantages of fail-safe motor starters over conventional safety systems • Significantly fewer components, therefore less complex configurations and considerably less HW engineering and wiring overhead • Rapid installation thanks to simple plug-in technology • Motor starters are fault tolerant and failsafe • High degree of flexibility thanks to assignment to switchoff groups in software • When the safety application changes, there is less overhead because the wiring is retained Two alternatives are available: Solution local • Used for locally restricted safety applications • For group deactivation of Standard, High-Feature or Failsafe motor starters without complex wiring for conventional safety systems • For local evaluation of EMERGENCY STOP circuits with automatic or monitored starting • Cascading of the shutdown groups • Can also be used in combination with external safety circuits Solution PROFIsafe • For usage with safety-related applications that are complex and interconnected • The logic of the safety functions (safe sensors can be freely assigned to Failsafe motor starters) is implemented with software and thanks to safety-related communication (PROFIsafe) • Safety module PM-DF PROFIsafe forms 6 shutdown groups • Selective and autonomous shutdown of the fail-safe motor starter for any safety function • Also for infeed to external safety systems through F-CM contact multiplier © Siemens AG 2012 I/O modules for simple applications 1) Module type Power modules for electronic modules and motor starters Information ■ ■ ■ ■ ■ Terminal modules PM-E 24 V DC with diagnostics or PM-E 24 ... 48 V DC, with diagnostics and status 1) PM-E 24 V DC to 230 V AC with diagnostics and fuse 1) PM-E RO 24 V DC with diagnostics PM-E F 24 V DC PROFIsafe for failsafe shutdown (max. Cat. 3) with standard modules PM-D F 24 V DC PROFIsafe for fail-safe motor starter ■ TM-P for power; TM-E for electronics 1) TM-D for motor starters ■ ■ 6ES7131-4. 2-, 4- and 8-channel Available from 24 V DC to 230 V AC; 0.5 to 5 A Different functionalities: Standard, High Feature Electronics and relays Sink output modules 4 DO 24 V DC/0.5 A 8 DO 24 V DC/0.5 A ■ 6ES7132-4. 2- and 4-channel Current and voltage input, thermocouple and resistance measurement Functionalities: Standard, High Feature, High Speed ■ 6ES7134-4. 2-channel Current and voltage output Functionality: Standard, High Feature, High Speed ■ 6ES7135-4. 2-channel, 24 V DC or 24...230 V AC, 5 A 2-channel, 24 V DC or 24...230 V AC, 5 A, channel-by-channel switching using front switch ■ 6ES7132-4HB. ■ ■ 6ES7138-4FA. 6ES7138-4FB. 6ES7138-4FC. 6ES7138-4FR. ■ 6ES7138-4AA. ■ 6ES7138-4GA. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Fail-safe modules ■ 2-, 4- and 8-channel Available from 24 V DC to 230 V AC Different functionalities: Standard, High Feature source input module 8 DI 24 V DC SRC Digital input modules 1) Relay module 1) ■ 6ES7 138-4CA. 6ES7 138-4CB. 6ES7 138-4CA. 6ES7 138-4CF. 3RK1 903-1. 6ES7193-4C. 3RK1903-0A. For supplying the ET 200S with digital inputs and outputs; High Feature variants increase the plant availability and offer additional functions and diagnostics. Analog output modules 1) ■ ■ Electronic modules Analog input modules 1) ■ For the electrical and mechanical connection of I/O modules and process wiring. Available with screw-type and spring-loaded terminals as well as the Fast Connect insulation-piercing technique ■ Digital output modules 1) Order No. group For supplying and monitoring the load voltage and encoder voltage; voltage and/or fuse failures; additional LEDs indicate the status of the voltage and the fuse; different function AC, DC, PROFIsafe and PROFIenergy. ■ ■ ■ ■ Failsafe input module 4/8F-DI 24 V DC PROFIsafe 1) Failsafe output module 4F-DO 24 V DC/2 A PROFIsafe 1) Failsafe input/output module 4F-DI/3F-DO 24 V DC/2 A PROFIsafe Fail-safe relay module 1F-RO 24 V DC or 24 - 230 V AC, 5 A Reserve modules Used as dummy modules for unused slots within an ET 200S station IO-Link The I/O-Link master module offers 4 I/O link channels with master functionality and enables the connection of intelligent IO-Link devices to the ET200S. All IO-Link functions are provided by ET200S to PROFIBUS DP or PROFINET I/O master modules. Simple data handling of IO-Link components is ensured via the configuration tool integrated in STEP 7. Up to 4 sensors, actuators or other IO-Link devices are each connected to a standard cable. In addition to central parameterization, IO-Link in SIMATIC S7 also enables expanded diagnostics up to device level. ■ 4-channel ■ ■ ■ You can find additional information on the IO-Link at www.siemens.com/io-link 1) Also available as SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (For details, see:www.siemens.com/siplus-extreme). SIMATIC ET 200S 27 © Siemens AG 2012 I/O modules for special applications, accessories 1) Module type Technology modules Measuring modules Information Order No. group For the solution of technological tasks, high-performance function modules are available that perform these tasks largely autonomously and relieve the CPU significantly. Used direct on site; parameterization using STEP 7 or GSD file; serial interface: ■ ■ High-speed counting and measuring tasks with 5V or 24V encoders Counter module 24 V DC / 100 kHz 1) Counter module 5 V DC / 500 kHz 1 COUNT ■ Simple positioning tasks through position sensing with SSI encoders SSI module 1 SSI 28 ■ 6ES7138-4DL. ■ 6ES7138-4DC. ■ Controlled positioning of simple drives via digital outputs 1 POS U positioning module ■ 6ES7138-4DD. ■ Positioning with stepper motors over a pulse/direction interface 1 STEP stepper motor module ■ 6ES7 138-4DF. ■ Proportioning, resetting and controlling of actuators and valves pulse module (timer, pulse-width modulation, stepper motor) 2 PULSE 1) ■ Serial data exchange via point-to-point connection 1 SI interface module 1) ■ 7MH4910-. ■ 7MH4920-. SIWAREX CS is a compact electronic weighing system with calibration capability for the distributed I/O system SIMATIC ET 200S. The SIWAREX CS weighing module can be used for various different measuring tasks such as container weighing, fill-level measurement, platform weighing, crane weighing as well as the measuring of forces and torques: ■ Uniform design and communication through integration in SIMATIC S7 ■ Use in distributed plant concept through connection to PROFIBUS DP via ET 200S ■ Measuring of weight or force with a resolution of 65,000 increments ■ Calibration according to OIML R76 ■ A display with calibration capability can be connected ■ Extensive diagnostics options ■ Easy to parameterize using the SIWATOOL CS program ■ Theoretical adjustment without adjustment weights ■ Replacement of module without renewed adjustment of scale ■ Use possible in Ex applications SIWAREX CF is a measuring module for connection of sensors operating according to the strain gauge principle. The module can be used for different measuring tasks, for example, measuring forces and torques: uniform design and system-wide communication thanks to integration into SIMATIC S7 1) ■ 6ES7138-4DA. 6ES7 138-4DE. 6ES7138-4DB. ■ Use in distributed plant concept through connection to PROFIBUS DP via ET 200S ■ Measurement with a resolution of ± 16,000 parts, accuracy 0.15% ■ Measurement rate 50 Hz ■ Ready-to-use, free application software "Getting started" Motor starter ■ Direct, reversing and soft starters ■ (also with integrated ■ Functionality: Standard, High Feature, Failsafe ■ 3RK1301-. 3RK1903-. safety system) ■ Up to 7.5 kW Accessories ■ Integrated shield connection system for low-impedance connections of individual lengths. Space-saving, low-cost standard components with a simple plug-in technique are used for this purpose.1) ■ 6ES7193-4.. ■ Individual color-coded labels for terminals on the terminal modules; they are available in different colors. ■ Labeling plates for numbering the terminal modules: inscribed or blank. ■ DIN A4 labeling sheets in different colors, pre-perforated; suitable for printing using a laser printer. Information: www.s7-smartlabel.de Also available as SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (For details, see:www.siemens.com/siplus-extreme) SIMATIC ET 200S © Siemens AG 2012 SIMATIC ET 200MP N The multi-channel and multi-functional S7-1500 I/O The ET 200MP I/O system with IP20 degree of protection is scalable and is used not only as a central IO for S7-1500, but also in a distributed configuration connected to PROFINET or PROFIBUS (available soon). As many as 30 IO modules can be inserted into each station. The modules have a low parts variance and the front connector is standardized for all 35 mm wide modules. This considerably simplifies ordering, logistics and storage of spare parts Wiring The front connectors have a pre-engaged position in which they are not yet electrically connected. In this position, the front connectors can be conveniently pre-wired. This means that rewiring and fault repair are possible during operation. Station design The module width has been reduced from 40 mm (S7-300) to 35 mm. Thanks to the smaller footprint, better use is made of the cabinet space. Pre-engaged position of front connector SIMATIC TOP connect – preassembled system cabling for digital and analog signals – is available to ensure fast assembly and to prevent wiring errors. SIMATIC TOP connect enables you to complete the wiring easily, quickly and safely. SIMATIC ET 200MP station design All IO modules have a standardized 40-pin front connector, which simplifies the ordering process and the storage of spare parts. Due to the self-assembling backplane bus, the IO system can be constructed on a scalable and flexible basis. In addition, an active backplane bus is being prepared that allows modules to be withdrawn or inserted during operation ("hot swapping"). In both cases, the same IO modules are used. For details, visit: www.automation.siemens.com/mcms/automation/en/ automation-systems/system-cabling/ simatic-top-connect/pages/default.aspx The circuit diagrams of the modules are printed on the inside doors. This enables servicing work to be carried out without detailed plant documentation or by less experienced personnel. Mechanical slot coding guarantees the unique assignment of module and front connector. This prevents wiring errors caused by the use of an incorrect front connector and protects the modules from being destroyed during replacement. In addition, the modules have electronic short-circuit protection. SIMATIC ET 200MP 29 © Siemens AG 2012 Standardized pinning Integrated shielding Modules of the same type have standardized pinning and are therefore wired the same way. This reduces the risk of errors and also enables the wiring to be performed reliably by less experienced personnel. The integrated shielding concept for analog modules makes the system more robust and more resistant to electromagnetic interference, thereby increasing plant availability. Potential groups Potential groups are easily formed by inserting jumpers in the front connector instead of wiring. This means that potential groups are more easily recognized and can be changed very easily. Cable space expands with system ET 200MP has a cable storage space that expands with the system and the front doors have two latching positions. This simplifies the wiring, particularly when cables with a large core cross-section and/or thick insulation are used. Labeling concept On the front, the modules have a small area available for equipment identification. Normal commercial labeling systems can be used for this. This enables modules to be identified more quickly and easily. The LEDs are assigned to the terminal and labeling on a 1:1 basis. This enables the wiring to be checked quickly and easily and ensures that the channel status is clearly readable. In the event of a fault, e.g. wire break on a channel, the corresponding LED lights up red. The fault can therefore be located quickly and precisely and then corrected. This reduces plant downtimes to a minimum. 30 SIMATIC ET 200MP © Siemens AG 2012 Diagnostics and display concept Electronic rating plate The display and diagnostics are consistent across all modules. Module and channel states are uniformly displayed in plain text – regardless of the type of module. Faults are displayed on a channel-specific basis so that they can be pinpointed and corrected faster. The user can configure substitute values for the event of a fault, so that the behavior of the module can be defined for the respective fault. All modules have an electronic rating plate as standard (I&M data), with which they can be identified quickly and clearly. For this reason, simple plant documentation is possible with software (e.g. TIA portal). Channel-specific parameter assignment Each channel of the IO modules can be configured individually. This increases the flexibility and enables changes during runtime to be performed more easily. Performance ET 200MP offers impressive performance in order to achieve the shortest possible response times and to implement the fastest applications. The high-speed backplane bus, special IO modules and the consistent use of PROFINET mechanisms contribute to this. Diagnostics and display concept High speed backplane SIMATIC ET 200MP 31 © Siemens AG 2012 Module overview The following interface modules and IO modules are available: Interface modules Order No. group IM 155-5 PN 6ES7 155-5AA0. IO modules 32 DI 16x24VDC HF 6ES7 521-1BH0. DI 32x24VDC HF 6ES7 521-1BL0. DI 16x24VDC SRC BA 6ES7 521-1BH5. DI 16x230VAC BA 6ES7 521-1FH0. DQ 16x24VDC/0.5A ST 6ES7 522-1BH0. DQ 32x24VDC/0.5A ST 6ES7 522-1BL0. DQ 8x24VDC/2A HF 6ES7 522-1BF0. DQ 8x230VAC/2A ST 6ES7 522-5FF0. DQ 8x230VAC/5A ST 6ES7 522-5HH0. AI 8xU/I/RTD/TC ST 6ES7 531-7KF0. AI 8xU/I HS 6ES7 531-7NF1. AQ 4xU/I ST 6ES7 532-5HD0. AQ 8xU/I HS 6ES7 532-5HF0. SIMATIC ET 200MP © Siemens AG 2012 SIMATIC ET 200M The S7-300 I/O with high channel density The ET 200M distributed I/O system is modularly designed with IP20 degree of protection. Up to 12 multi-channel signal modules (e.g. 64 digital inputs) and function modules as well as S7-300 communications processors can be used as I/O modules – the interface to the process. There are no slot rules. Hot swapping and expansion of modules is permissible when using active bus modules. Connection to PROFINET and PROFIBUS is made via interface modules. In addition to screw-type and spring-loaded terminals, connection of the signals can be made even simpler and faster using SIMATIC TOP connect. Preassembled front connectors with single conductors and a complete plug-in modular system are available. FastConnect plugs do not require the cables to be stripped. The cable is simply plugged in and the contact is made using the insulation displacement method. The PROFINET version of the ET 200M offers new functions, e.g.: • Shared device • Media redundancy protocol (MRP) When the ET 200M is operated with an S7-400H/FH on PROFIBUS, the availability of the plant can be increased: • Switched connection: One ET 200M with two interface modules • Redundant connection: Two ET 200M with one interface module each When the ET 200M is connected to PROFIBUS on an S7-400, the controller can be configured during normal operation (Configuration in RUN - CiR). In this manner, • complete ET 200M I/O stations can be added, • individual modules can be added within a station, and • individual digital and analog module parameters can be modified. Hot swapping of signal modules is possible, thus reducing downtimes. Failsafe I/O modules permit the integration in safety-related plants with SIMATIC Safety Integrated. ET 200M with PROFINET connection and S7-300 modules FastConnect The insulation displacement method Fast Connect offers even more benefits when wiring the I/O modules: • Available as 20-pole and 40-pole variants • Suitable for all S7-300 I/O modules • Permissible core crosssections: 0.5 … 1.5 mm² • Suitable for rigid and flexible conductors • Opening for test tip with a diameter of up to 1.5 mm FastConnect plug for ET 200M • Time savings of up to 60% for installation as compared to conventional connection methods • No stripping or crimping necessary • Easy, secure installation with a screwdriver • Reduction in the number of installation errors • The stripped length does not have to be determined SIPLUS components also enable operation in the extended temperature range -40 °C ... +70 °C and in corrosive atmospheres or under condensation conditions (for details, see: www.siemens.com/siplus-extreme). SIMATIC ET 200M 33 © Siemens AG 2012 Interface modules for PROFIBUS and PROFINET The various S7-300 modules in the distributed I/O system ET 200M are connected to the bus system via the interface module – either to the well-proven PROFIBUS fieldbus or to PROFINET, the open Industrial Ethernet standard. Interface module IM 153-4 for PROFINET The following interface modules are available: Interface modules IM 153-15) IM 153-2 HF 5) IM 153-4 PN 5) PROFIBUS Copper Copper IM 153-4 PN HF 2-port switch 1)/MRP -/- -/- Copper Copper n/n Number of modules 8 n/n 12 12 Station width 12 360 mm 520 mm 520 mm 520 mm Diagnostics Channel-specific Channel-specific Channel-specific Channel-specific Time synchronization on PROFIBUS, time stamping of alarms 2) - n - - Use of function modules (FM) and communications processors (CP) Restricted n n n Routing of parameterization data to intelligent field devices - n - n Connection to fault-tolerant (redundant) systems (S7-400H) - n - - In the redundant system - n - - Fail-safety (PROFIsafe) - n - n Isochronous mode 3) - n - Shared device - - n n Electronic rating plate 4) - n n n Firmware update - Bus Bus/Micro Memory Card Bus/Micro Memory Card Order No. group 6ES7 153- 1AA. 2BA. 4AA. 4BA. PROFINET (HART) (HART) In the non-redundant system n can be used / available - cannot be used / not available 1) 2) 3 34 The integrated 2-port switch of the IM 153-4 now also easily permits a ring configuration by means of MRP functionality in addition to the star topology. Changes to digital inputs are tagged with a time stamp locally (in the IM 153 of the ET 200M) and transferred to the CPU by means of a process interrupt. Isochronous mode is the synchronized coupling of distributed I/O and the user program on PROFIBUS with a constant cycle time. In this manner, actual value sensing and setpoint output are performed synchronously and with a constant cycle time and with consistent data images. SIMATIC ET 200M 4) 5) The "electronic rating plate" or identification data are the data stored in a module such as the order number, product version, installation date, or plant identifier that uniquely identify this module and which are available online, for example, to facilitate troubleshooting. Also available as SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (for details, see: www.siemens.com/siplus-extreme). © Siemens AG 2012 S7-300 modules 1) The multi-faceted module range of S7-300 enables the ET 200M to be modularly adapted to a wide range of different tasks. Digital modules Function Order No. group SM 321 Digital input SM 321, 8DI 1) 6ES7 321-1FF. Digital input SM 321, 16DI 1) 6ES7 321-1*H. Digital input SM 321, 32DI 1) 6ES7 321-1*L. Digital input SM 321, 64DI 6ES7 321-1BP. Digital output SM 322, 8DO 1) 6ES7 322-8*F. Digital output SM 322, 16DO 1) 6ES7 322-1*H. Digital output SM 322, 32DO 1) 6ES7 322-1*L. Digital output SM 322, 64DO 6ES7 322-1BP. SM 323 Digital input/output SM 323, 8DI/8DO or 16DI/16DO 1) 6ES7 323-1B*. SM 327 Digital input/output SM 327, 8DI/8DX 6ES7 327-1BH. Analog modules Function Order No. group SM 331 Analog input SM 331, 2AI 1) 6ES7 331-7KB. Analog input SM 331, 6AI 6ES7 331-7PE. Analog input SM 331, 8AI 1) 6ES7 331-7*F. Analog output SM 332, 2AO 1) 6ES7 332-5HB. Analog output SM 332, 4AO 1) 6ES7 332-**D. Analog output SM 332, 8AO 1) 6ES7 332-5HF. Modules for technological functions Function Order No. group FM 350-1 Counting, measuring 1) 6ES7 350-1AH. FM 350-2 Counting, measuring, proportioning 1) 6ES7 350-2AH. FM 351 Controlled positioning in rapid traverse/creep speed 6ES7 351-1AH. FM 352 Electronic cam control 6ES7 352-1AH. FM 352-5 High-speed Boolean operations 6ES7 352-5AH. FM 353 Positioning with stepper motors 6ES7 353-1AH. FM 354 Positioning with servo motors 6ES7 354-1AH. FM 355C Universal closed-loop control (continuous closed-loop control) 6ES7 355-0VH. FM 355S Universal closed-loop control (step controller) 6ES7 355-1VH. FM 355-2 Temperature control with self-optimization 6ES7 355-2CH. FM 357-2 Multi-axis interpolation, synchronous operation 6ES7 357-4AH. SIWAREX U Single-channel or dual-channel universal weighing module 1) 7MH4601-1. SIWAREX FTA Fast weighing and dosing module with calibration capability 7MH4900-2. SIWAREX FTC Module for continuous weighing tasks 7MH4900-3. SIFLON FC Function module for industrial flow measurement 7ME4120. SM 322 SM 332 1) Standard modules (digital and analog modules) and modules for special applications are available: Also available as SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (for details, see: www.s iem ens. com / sipl u s-extrem e). SIMATIC ET 200M 35 © Siemens AG 2012 1) 1) 36 Modules for fail-safe systems Function Order No. group SM 326F DI 24 Digital input (24 x 24 V single-channel or 12 x 24 V dual-channel) 1) 6ES7 326-1BK. SM 326F DI 8 NAMUR Digital input (8 x NAMUR single-channel or 4 x NAMUR dual-channel) 1) 6ES7 326-1RF. SM 326F DO 10PP Digital output (10 x 24 V) 1) 6ES7 326-2BF. SM 326F DO 8PM Digital output (8 x current sourcing/sinking) 1) 6ES7 326-. SM 336F AI 6 Analog input (0/4…20 mA, HART) 1) 6ES7 336-4GE. Isolation module Galvanic isolation between standard and fail-safe HART modules 1) 6ES7 195-7KF. Modules for hazardous areas Function Order No. group SM 321 Digital input (4 x NAMUR) 1) 6ES7 321-7RD0. SM 322 Digital output (4 x 15 or 24 V) 6ES7 322-5.D0. SM 331 Analog input (4 x 0...20 mA or 4...20 mA) 1) 6ES7 331-7RD0. SM 331 Analog input (8 thermocouples or 4 thermoresistors) 1) 6ES7 331-7SF0. SM 332 Analog output (4 x 0...20 mA or 4...20 mA) 6ES7 332-5RD0. SM 331 HART analog input (2 x 0…20 mA or 4…20 mA) 1) 6ES7 331-7TB0. SM 332 HART analog output (2 x 0...20 mA or 4...20 mA) 6ES7 332-5TB0. Also available as SIPLUS component for extended temperature range -40 °C … +70 °C and corrosive atmosphere/condensation (for details, see: www.s iem ens. com / sipl u s-extrem e). SIMATIC ET 200M © Siemens AG 2012 SIMATIC ET 200iSP The intrinsically-safe version for hazardous areas The independent wiring supports easy, reliable replacement of modules during normal operation. Hot swapping of the power supply is possible without arcing. PROFIBUS DP and/or the power supply can also be redundantly implemented. HART support ET 200S with redundant PROFIBUS connection ET 200iSP can be used in hazardous areas with a gas or dust atmosphere: • The ET 200iSP station can be installed in Zones 1, 21 and 2, 22. • The connected sensors and actuators can also be located in Zones 0 and 20. Communication between the field devices and the process control system or automation system is performed over PROFIBUS DP. This considerably reduces the wiring outlay. The terminal blocks commonly used today, as well as the necessary distribution boards and Ex isolating transformers for the signals, can be omitted. PROFIBUS DP has established itself as the standard bus in the field level right up to hazardous areas. This open and systemwide communication keeps the solution flexible and also open to other manufacturers. International standardization of PROFIBUS DP also ensures future protection to the customer for investments that are often considerable and intended to last for many years. ET 200iSP supports high availability of the system thanks to: • Configuration during normal operation • Hot swapping • Redundancy During normal operation • stations can be added, • stations can be expanded with modules, and • module parameters changed. ET 200iSP offers the HART protocol for connecting process devices with HART capability. These HART modules also support the transfer of auxiliary variables. Apart from the actual measured value, up to four IEEE variables can be transferred in the process image. By means of a routing function, a central station can access the HART process devices transparently over PROFIBUS DP. A higher-level control system can therefore perform central data administration. The process devices are connected by means of a 4 to 20 mA analog signal. Further device information is transferred over a modulated signal: • Parameters that are specified by a central engineering station (routing) • Diagnostics data that are read by the engineering station This principle is called HART (Highway Addressable Remote Transducer). The majority of process instruments, e.g. for temperature, level, pressure or flow measurements, have HART connections. Powerful diagnostics with SIMATIC PCS 7 With SIMATIC ET 200iSP, numerous items of diagnostics information are generated when internal and external faults occur, e.g. on open-circuit or short-circuit. The HART status of the connected HART field devices such as maintenance and additional information is mirrored in the diagnostics and signaled to the host control system. Standard diagnostics drivers are available for SIMATIC PCS 7 for the diagnostics messages. These drivers prepare all the relevant signals for the higher-level PCS 7 Operator System. The detected faults are transferred quickly to the higher-level systems and support online diagnostics from a central point at any time. A watchdog module monitors the ET 200iSP by means of • targeted reading or writing of I/O data • Reading an input that switches (toggles) with a constant frequency • Provision of an intrinsically safe power supply for the deactivation signal of the digital outputs SIMATIC ET 200iSP 37 © Siemens AG 2012 Modular, intrinsically safe design The ET 200iSP is installed in just a few steps: Safe in the field with the isolating transformer • The terminal modules are snapped onto the rugged and well-proven S7-300 standard rail • Prewiring without electronics modules with spring-loaded and screw-type terminals • No need for tools, because the power supply, interface module and electronics modules are simply plugged in So that all the advantages of a failsafe bus installation are also available with PROFIBUS DP, an isolating transformer is used to make PROFIBUS DP intrinsically safe. This is done by isolating the bus and limiting the energy in the safe area. The fieldbus isolating transformer is used here as a barrier that converts PROFIBUS DP to an intrinsically safe PROFIBUS DP. It allows the PROFIBUS connector to be disconnected and connected even under Ex conditions. You can find the SIMATIC Selection Tool on the Internet at: www.siemens.com/et200 as well as in the Industry Mall or the Catalog CA01 on DVD Interface module Fieldbus isolating transformer The fieldbus isolating transformer offers the following advantages: • Plug and Play without the need for time-consuming circuit calculations and certifications (PROFIBUS International guidelines 2262) • Simple modification/expansion • Connection of numerous devices • Implementation as a barrier or repeater Electronic modules EEx ib Terminal modules for electronic modules Power supply Ex d-protected 24 V DC or AC 85 ... 264 V Mounting rail Terminal module for interface module PROFIBUS DP connection Ex ib intrinsically safe Modular design of the ET 200iSP 38 SIMATIC ET 200iSP Connecting terminals EEx ia/ib © Siemens AG 2012 Basic modules for the configuration High-capacity power supply Interface module IM 152 The power supply with the explosion-proof casing provides all the voltages and currents required for operation of the ET 200iSP and feeds them into the backplane bus of the terminal modules. The 24 V or 230 V supply is connected to the power supply terminal through EEx e terminals. The power supply supplies the ET 200iSP with safe galvanically isolated operational voltage for: Interfacing to the intrinsically safe PROFIBUS DP with transmission rates up to 1.5 Mbit/s over the IM 152 interface module. The IM 152 communicates autonomously with the higher-level system (PLC or master system). • Up to 32 electronics modules • PROFIBUS DP interface of IM 152 • Supply of sensors/actuators It is also possible for digital process signals to be tagged with a time stamp. The firmware of the IM 152 can also be upgraded with a plug-in SIMATIC Micro Memory Card (MMC) or via bus. It provides for the safety-related limitation of the output voltages. The PS has an explosion-proof metal casing (EEx d explosion protection) and is permitted to be removed and replaced in the working position (hot swapping) under hazardous conditions. It provides up to 5A for supplying the modules and the sensors and actuators. In fault-tolerant solutions, two power supplies can be configured redundantly. Power Supply PS 138 For I&M purposes (Identification & Maintenance), the IM 152 and the electronics modules have an electronic rating plate1). The IM 152 interface module and the PROFIBUS connector may be removed and replaced under hazardous conditions. With fault-tolerant solutions, up to two IM 152 modules can be configured redundantly. Interface module IM 152 Power supply 24 V DC/5 A 85 ... 264 V AC/5A Transfer rate 9.6 Kbit/s...1.5 Mbit/s Dimensions 60 x 190 x 136.5 mm 60 x 190 x 136.5 mm Protocol PROFIBUS DP Interface RS 485 iS 6ES7 138-7EA. 6ES7 138-7EC. Firmware update PROFIBUS, Micro Memory Card Dimensions 30 x 125 x 136.5 mm Order no. group 6ES7 152-1AA. Terminal modules Order no. group TM-PS-A for PS 24 V DC 6ES7 193-7DA1. TM-PS-B for PS redundant 24 V DC 6ES7 193-7DB1. TM-PS-A for PS 85...264 V AC 6ES7 193-7DA2. TM-PS-B for PS 85 ... 264 V AC redundant 6ES7 193-7DB2. TM-IM/IM for two IMs 6ES7 193-7AB. TM-IM/EM for IM and one EM 6ES7 193-7AA. TM-EM/EM for two EMs 6ES7 193-7CA. TM-RM/RM for 2 RMs (relay modules) 6ES7 193-7CB. Dimensions 60 x 190 x 52 mm Other components Order no. group Reserve module 6ES7 138-7DA. Watchdog module 6ES7 138-7BB. Order No. group Power Supply – can also be used redundantly Redundant IM 152 interface module 1)The "electronic rating plate" or identification data are the data stored in a module such as the Order No., product version, installation date or plant identifier that uniquely identify this module and which are available online, to facilitate troubleshooting, for example. SIMATIC ET 200iSP 39 © Siemens AG 2012 Digital and analog electronics modules The output modules have a special input for fail-safe deactivation: • H deactivation (active high) • L deactivation (active low) Input/output modules 2-channel, 4-channel and 8-channel digital and analog input/output modules are available for the ET 200iSP (dimensions: 30 x 125 x 136.5 mm). External actuator deactivation is often required in plants in the event of evacuation or an emergency. L deactivation also ensures wire-break monitoring. The digital output modules permit load-free switching of the digital outputs. The digital and analog process signals are matched to ET 200iSP via these electronics modules (EM). Fail-safe input/output modules Three fail-safe modules are available for digital input, digital output and analog input up to SIL3/PLe for use up to Zone 1 or 21. This means the otherwise required Ex barrier can be ignored for the SIL calculation. The electronics modules support the connection of HART process devices and Electronic module all generally available EEx i valves and therefore offer flexible application possibilities. The process signals are connected via the terminals of the associated terminal modules with either screw-type or springloaded connection. Digital electronic module 2 DO Relay For the connection of certain actuators such as solenoid valves, hydraulic valves, DC contactors and indicator lights, signals with an increased current load are often required. In order to connect such devices there is a 2 DO Relay module available with two outputs, each with 2 A output current. The contacts are NO contacts with galvanic isolation from the supply voltage. All EMs are designed as the EEx i "intrinsically safe" modules and can be easily replaced under Ex conditions (hot swapping). Digital modules Application NAMUR encoder, etc. Valves, indicator lights, DC relays, etc. Magnetic hydraulic valves, DC contactors, indicator lights NAMUR encoders and single contacts with/without resistance circuit Solenoid valves Module Number of channels Special feature 8 DI NAMUR 8 4 DO 4 2 DO Relay 2 with 2 A each 8 F-DI Ex NAMUR 8 4 F-DO Ex 17.4V/40mA 4 2 channels can be used as ■ Counter (max. 5 kHz) ■ Frequency meter (1 Hz ... 5 kHz) ■ With gate function 6ES7 131-7RF. ■ ■ ■ ■ Up to SIL 3, PLe, Pulse Stretching, 1oo2 on module possible; FW update via network Up to SIL 3, PLe, parallel switching of outputs, Energize To Trip [ETT] diagnostics, Last valid value; FW update via network 6ES7138-7FD0. Order no. group 1) 25.5 V DC, 22 mA 23.1 V DC, 20 mA 17.4 V DC, 27 mA 17.4 V DC, 40 mA 6ES7 132-7RD. 1) 6ES7 132-7GD. 2) ■ ■ UC 60V/2A Hot swapping in Ex-Zone 1 6ES7 132-7HB0. 6ES7138-7FN. H deactivation, 2) L deactivation Analog modules Application Resistance thermometer (Pt100, Ni100) Resistance test 600 Ω Thermocouple types B, E, J, K, L, N, R, S, T, U Thermal e.m.f. (± 80 mV) Module Number of channels Resolution Order no. group 4 AI RTD 4 15 bit + sign 6ES7 134-7SD5. 4 AI TC 4 15 bit + sign 6ES7 134-7SD0. Analog HART modules Use as HART module Use as analog module 40 HART process devices 2-wire transducer 4 - 20 mA 4-wire transducer 0 - 20 mA, 4 - 20 mA Current output 0 - 20 mA, 4 - 20 mA 0/4...20mA encoder with/without HART Module Number of channels Resolution Special feature 4 AI I 2 WIRE HART 4 4 AI I 4 WIRE HART 4 4 AO I HART 4 4 F-AI Ex HART 4 12 bit + sign 12 bit + sign 14 bit Order no. group 6ES7 134-7TD0. 6ES7 134-7TD5. 6ES7 135-7TD0. 15-bit resolution + sign Up to SIL 3, PLe, HART communication V7.0; FW update via network 6ES7138-7FA. SIMATIC ET 200iSP © Siemens AG 2012 Standards, approvals and accessories Standards and approvals ATEX II 2 G (1) GD I M2 Ex de [ia/ib] IIC T4 Ex de [ia/ib] I IECEx Zone 1 Ex de [ia/ib] IIC T4 NEPSI Ex ib [ia] IIC T4 Ex e [ia/ib] IIC T4 GOST Ex ib [ia] IIC T4 Ex e [ia/ib] IIC T4 INMETRO Zone 1 BR-Ex de [ia/ib] IIC T4 cFMus Class I, II, II NI Division 2, Groups A,B,C,D,E,F,G T4 AIS Division 1, Groups A,B,C,D,E,F,G Control cabinets available as accessories cULus The housings (control cabinets) are suitable for hazardous areas of Zones 1 and 2 as well as 21 and 22. They either have surface treatment or are made of non-corrosive material. Class I Zone 1, AEx de [ia/ib] IIC T4 Class I, II, II Division 2, Groups A,B,C,D,E,F,G T4 providing int. safe circuits for Division 1, Groups A,B,C,D,E,F,G Class I The permissible operating temperature lies between -20 °C and +70 °C. The main components in the scope of supply of the housing are: • Housing with wall bracket • Mounting rail • Equipotential bonding strip • Cable and wire grommets Zone 1, AEx de [ia/ib] IIC T4 CE According to 94/9/EC (previously ATEX 100a), 2004/108/EC and 2006/95/EC KCC Korea Certification Marine approval Classification societies ■ ABS (American Bureau of Shipping) ■ BV (Bureau Veritas) ■ DNV (Det Norske Veritas) ■ GL (Germanischer Lloyd) ■ LRS (Lloyds Register of Shipping) ■ Class NK (Nippon Kaiji Kyokai) Pneumatic system expansions Accessories Order no. group Fieldbus isolating transformer 6ES7 972-0AC. PROFIBUS cable for intrinsically safe PROFIBUS RS 485-iS 6XV1 831-2A. PROFIBUS DP connector 6ES7 972-0DA6. Control cabinets 6DL2 804. Ambient temperature 1) Modular in design, fully integrated into the system – ET 200iSP with valve modules from Bürkert. For horizontal mounting 1) -20 °C ... +70 °C For other mounting positions: -20 °C ... +50 °C For details and further information, please refer to the product description: www. sie mens .c om/ ET 20 0i SP You can find these and other accessories in our Add-ons Catalog ST PCS7.1 • 2011 SIMATIC ET 200iSP 41 © Siemens AG 2012 SIMATIC ET 200pro Compact and multi-functional SIMATIC ET 200pro is an especially rugged and high-performance I/O system with IP65/66/67 degree of protection. It does not require a control cabinet and can be mounted directly on the machine. Its modular and time-saving structure allows flexible, customized, distributed automation solutions to be implemented. ET 200pro can be connected to well-proven fieldbuses such as PROFIBUS or to PROFINET, the leading Industrial Ethernet standard for company-wide automation. Communication here can also take place via Industrial Wireless LAN as well as using cables solutions. ET 200pro offers comprehensive diagnostics to reduce the downtimes of your plant: • The standard modules also offer module diagnostics for short-circuiting of the encoder supply or the outputs. • The High Feature modules offer more precise diagnostic functions through channel diagnostics for short-circuit and wire-break. Additional process interrupts can be used for digital inputs for six channels. • Diagnostic alarms are reported to the higher-level PLC over PROFIBUS or PROFINET in the form of plain text. ET 200pro with PROFIBUS connection 42 SIMATIC ET 200pro Fail-safe electronic modules and high-feature interface modules are available for automation tasks with maximum safety demands. The electronic modules can be used on their own in a station, or in mixed configurations with standard modules. Together with the failsafe SIMATIC S7-300F and S7-400F controllers, automation tasks can be solved with safety requirements up to SIL 3 (EN 61508) or up to Category 4 (EN 954-1) – efficiently and without cabinets. With the F-CPU module, local, safety-related applications can also be set up. Failsafe communication between the ET 200pro and the higher-level or integral failsafe CPU is achieved using PROFIsafe – cabled via PROFIBUS and PROFINET or wirelessly via Industrial Wireless LAN. You can find the SIMATIC Selection Tool on the Internet at: www.siemens.com/et200 as well as in the Industry Mall or the Catalog CA01 on DVD ET 200pro with PROFINET connection, CPU and RFID module © Siemens AG 2012 Modular, space-saving design The ET 200pro has a modular and extremely compact design. Up to 16 modules can be combined in any way over a length up to one meter. An ET 200pro station can be preassembled on the work bench with narrow module carriers and then fitted to the machine as a complete unit. Alternatively, the compact module carrier can also be fixed in place first and the station can be assembled later. The modules are simply latched into the module carrier and pushed onto each other. Module carriers are available in lengths of 0.5 m, 1 m and 2 m. 8-channel electronic modules can be combined with the 8 x M12 or 4 x M12 connection modules. This gives you the choice of single or dual assignment of the M12 sockets. A wide variety of different sensors and actuators can therefore be connected to the electronic module without the need for additional accessories such as Y connectors or Y leads. This not only reduces the wiring but also the costs for accessories and parts inventories. Wiring with connection modules 8xM8, 2xM12 and 1xM23 is also possible. The expansion modules are divided into bus module, electronic module and connection module: • The bus module contains the backplane bus for signals and supply voltage in build-as-you-go design. • The electronic module determines the function and is easily replaced during normal operation with the equipment live (hot swapping). The station therefore remains functional in the event of a fault. Coding prevents the wrong module from being plugged in inadvertently. • The connection module with permanent wiring is plugged on and screwed down with 2 screws. Pre-assembled connecting cables can be attached quickly and easily. Failsafe I/O modules permit the integration in safety-related plants with SIMATIC Safety Integrated. Selective formation of load groups Power modules allow load groups to be built up as required by supplementary supply from the load power supply. In this case, the same connection techniques (direct connection; M12, 7/8"; ECOFAST) are available as for the power supply of the complete station. More than one load segment can be integrated into a single station. In the interface and in each power module, built-in fuses ensure that neither total failure of all load groups, nor damage beyond the station can occur. Modular design of the ET 200pro SIMATIC ET 200pro 43 © Siemens AG 2012 Interface modules for PROFIBUS The interface modules (IMs) for PROFIBUS can be combined with three different modules for connecting the bus and power supply. All connection modules for PROFIBUS have visible address setters that allow the addresses to be easily read as well as a selectable terminating resistor. The integrated T functionality supports the start-up of partial segments and uninterrupted bus communication in the event of a servicing requirement. • Direct connection with cable gland: For up to 16 A electronic load and a cross-section of up to 2.5 mm². • ECOFAST (Energy and Communication Field Installation System) – The standardized Siemens connection technique for cabinet-free distribution is based on hybrid cables for bus signals and power supply. • M12, 7/8'': The familiar connection method with widely implemented connector standard. Interface modules IM 154-1 DP IM 154-2 DP HF Protocol PROFIBUS DP Transfer rate, max. 12 Mbit/s Firmware update via PROFIBUS Dimensions (with connection module) 90 x 130 x 173 mm PROFIBUS IM with M12, 7/8" connection With CM IP DP M12, 7/8" 90 x 130 x 120 mm With CM IP DP directly 90 x 130 x 80 mm PROFIBUS IM with direct connection With CM IP DP ECOFAST Order No. group 6ES7 154-1. 6ES7 154-2. PROFIBUS IM with ECOFAST connection 44 SIMATIC ET 200pro © Siemens AG 2012 Interface module for PROFINET The interface module (IM) for PROFINET contains a 2-port switch for easy configuration of a line structure. More parameters are possible per station using PROFINET, and therefore more high-function modules can be used. In case of service, the IM can be replaced without using a programming device – the device name and parameters remain on the module. As with the PROFIBUS variant, the interface module and the connection module on the interface module IM 154-4 PN HF are separated so that various connection methods are possible. It supports the PROFINET functions: • IRT • Media redundancy protocol (MRP) • Shared device The interface module offers both the proven M12 7/8" connection and the option of the connection with push-pull technology. The integrated switch enables the easy construction of line structures. Interface module IM 154-4 PN HF Function PROFINET interface module HF for ET 200pro with integrated switch and data transmission rate up to 100 Mbit/s Mounting dimensions W x H x D (mm) 135 x 130 x 50.8 Order No. group 6ES7 154-4AB. The following connection modules are available: Connection module CM IM PN M12, 7/8" 2xRJ45 2xSCRJ FO Function Connection module for PROFINET interface module ET 200pro Connection options 2x M12 and 2x 7/8" Interface module for wireless data transfer With the new interface module IM 154-6 PN HF IWLAN (Industrial Wireless LAN), the distributed I/O system ET 200pro can now be connected wirelessly to a higherlevel PROFINET IO Controller for the first time. IM 154-6 PN HF IWLAN communicates Interface module IM 154-6 PN HF wirelessly as an IWLAN client IWLAN for wireless data transfer with an IWLAN Access point of the communication network (e.g. SCALANCE W). Both standard and safety-related applications can be implemented via this wireless connection with PROFINET. IM 154-6 PN HF IWLAN is especially well-suited for overhead monorail conveyors, automated guided vehicle systems, building management and warehouse logistics. An integrated web server allows very easy setting and parameterization. Modern procedures (e.g. encryption, authentication) ensure a high degree of data security. Antennas and antenna cables are available as accessories. Interface module IM 154-6 PN HF IWLAN Function Wireless PROFINET connection WLAN standards IEEE 802.11 a/b/g/h/e/i Frequency bands 2.4 and 5 GHz Transfer rate 54 Mbit/s WLAN services Optimized media access, uninterrupted wireless cell switching, anti-interference mechanisms Mounting dimensions W x H x D (mm) 90 x 130 x 50.8 Order No. group 6ES7 154-6AB. 2x RJ45 or 2x SCRJ FO 2x push-pull power connectors Dimensions W x H x D 90 x 130 x 50.8 mm 90 x 130 x 50.8 Order No. group: 6ES7... 194-4AJ00-0AA. 194-4AF00-0AA. 194-4AG00-0AA. SIMATIC ET 200pro 45 © Siemens AG 2012 CPU module Power supply module CPU modules (with F-CPU) The interface modules IM 154-8 PN/DP CPU and IM 154-8F PN/DP with CPU functionality are based on the CPU 315-2 PN/DP and offer the same quantity structures and functions. Both IM 154s have two communication interfaces, Fail-safe CPU module for • one combined MPI/ ET 200pro PROFIBUS DP interface, and • one PROFINET interface with three ports. The IM 154-8 PN/DP CPU supports both PROFINET IO (up to 128 IO devices can be connected) and PROFINET CBA, as well as PROFIBUS DP (as master for up to 124 slaves). The IM 154-8 PN/DP CPU is not only compatible with the programs of the S7-300 CPUs, but it also offers a high degree of data retentivity (protection against voltage failure). A separate LED signals maintenance alarms. Modules can be replaced easily thanks to the Micro Memory Card. Firmware can be updated over the network. Furthermore, a web server functionality for information, status, diagnostics, clock synchronization via the Ethernet (NTP) is available. The open Ethernet communication (TCP/IP, UDP, ISO-on-TCP) permits reliable and high-speed data exchange. Isochronous mode is possible on the PROFIBUS. There is less loading on the central controller because individual plant sections can be configured, started up, diagnosed and operated individually. CPU modules IM 154-8 PN/DP CPU IM 154-8F PN/DP CPU IM 154-8FX PN/DP CPU PN/DP connection block CM IM PN DP M12 7/8" Memory 384 KB / 85 k statements 512 KB / 85 k statements (F-IM) 1.5 MB / 256 k statements (F-IM) Interfaces X1: MPI/DP interface (2x M12) X2: PN interface (2x M12, 1x RJ45) 46 CPU mounting dimensions W x H x D (mm) 135 x 130 x 59.3 Connection block mounting dimensions W x H x D (mm) 90 x 130 x 50.8 CPU Order No. group 6ES7 154-8AB. 6ES7 154-8FB. 6ES7 154-8FX. Connection block Order No. group 6ES7 194-4AN. SIMATIC ET 200pro The power supply module converts 3-phase rated voltages from 380 to 480 V into controlled DC voltage and reliably supplies power to the I/O system with up to 8 A. Thus, the ET 200pro can be very easily supplied with the often available 3-phase con- ET 200pro power supply module for 380 to 480 V nector, without needing its own 24 V power supply. The controlled 24 V power supply feeds the connecting modules for the electronics/encoder (1L+) and load voltage supply (2L+). To supply a new potential group (2L+), the 4-pin 24 V cable is connected to the power module. To cover power failures, the power supply unit can be expanded with a SITOP UPS500P. The absolutely maintenance-free 24 V/7 A UPS module on a capacitor basis is also designed in IP65 and is suitable for ambient temperatures up to +55 °C. Power supply module Input voltage 380 ... 480 V (340...550 V) 3 AC Frequency 50/60 Hz (45 ... 66 Hz) Output voltage 24 V DC Output current 8A Short-circuit protection Electronic, independent restart Mounting dimensions W x H x D (mm) 310 x 135.5 x 90 Order No. group 6ES7 148-4PC. © Siemens AG 2012 Electronic modules Electronic modules RFID communication Digital electronic modules with 4 and 8 channels for 24 V and 4-channel analog electronic modules are available for voltage, current, and resistance thermometers. Digital electronic modules Order No. group EM 8 DI DC 24V 6ES7 141-4BF. EM 8 DI DC 24V HF 6ES7 141-4BF. EM 16 DI DC 24V 6ES7 141-4BH. EM 4 DO DC 24V, 2A 6ES7 142-4BD. EM 4 DO DC 24V, 2A HF 6ES7 142-4BD. EM 8 DO DC 24V, 0.5A 6ES7 142-4BF. EM 4DI / 4DO DC 24 V, 0.5 A 6ES7 143-4BF. RFID communication module RF 170C Order No. group Electronic module 6GT2002-0HD. Connection block 6GT2002-1HD. NEW EM 4 DIO / 4 DO DC 24 V, 0.5 A 6ES7 143-4BF. Analog electronic modules Order No. group EM 4 AI U HF 6ES7 144-4FF. EM 4 AI I HF 6ES7 144-4GF. EM 4 AI RTD HF 6ES7 144-4JF. EM 4 AI TC HF 6ES7 144-4PF. EM 4 AO U HF 6ES7 145-4FF. EM 4 AO I HF 6ES7 145-4GF. Digital electronic modules 8 DI and 4 DO Different connection modules are available for screwing onto the I/O: • CM IO 8 x M8 • CM IO 2 x M12, 4 x M12, CM 4 x M12 inverse, 8 x M12, 8 x M12D • CM IO 1 x M23 Fail-safe modules Fail-safe electronic modules Order No. group EM 8/16 F- DI DC 24V 6ES7 148-4FA. EM 4/8 F-DI/4 F-DO DC 24V 6ES7 148-4FC. The following connection modules are available: • CM IO F 12xM12 • CM IO F 16xM12 Fail-safe digital module 4/8 F-DI/4 F-DO SIMATIC ET 200pro 47 © Siemens AG 2012 Compact, intelligent motor starters The intelligent ET 200pro motor starters are used for starting and protecting motors and loads of up to 5.5 kW. They are available as Standard and High Feature electromechanical motor starter and High Feature electronic motor starter versions. The electromechanical motor starter is switched with conventional contactors and is offered as direct or reversing starter with optional 400 V brake control. The electronic motor starter is equipped with semiconductor switching elements and is therefore esSIMATIC ET 200pro with electromepecially suited for applicachanical/electronic motor starter tions with high switching frequencies. This high feature device not only handles the direct on/off switching of motors with high switching frequency, but also fulfills the additional function of a full-fledged soft starter for a soft startup and stoppage. The conversion from motor starter to soft starter is achieved using simple re-parameterization in SIMATIC Manager. The High Feature motor starters differ from the Standard motor starters in that they have more parameters and feature four parameterizable digital inputs. Parameterization is easy and convenient to carry out using the SIMATIC Manager. The motor starters ET 200pro feature high functionality with a small footprint, as well as simple and fast configuration and installation – and they increase the availability of production plants. Easy installation 48 ic overload protection increases the availability of the drive system. An upward or downward violation is signaled by the ET 200pro to the host controller, resulting in high plant availability. The motor starter recognizes unbalanced load currents, and switches these off directly. All motor protection functions can be defined by simple parameterization. The local control station which is sometimes required for a drive is provided via the integral digital inputs (High Feature motor starter) and can therefore be easily incorporated into the control system. Special modules for further functions If required, a maintenance switch module can be used that isolates series-connected starters from the supply voltage, for example. Safety modules The Safety Motorstarter Solution local or Solution PROFIsafe is used for safetyoriented applications. For local safety applications, the safety local repair switch module with safe input and Maintenance switch module the 400 V disconnecting module are used. These two components permit a safe shutdown of the 400 V supply of the series-connected motor starters. PROFIsafe solutions are implemented quickly and easily by using an F switch module in combination with a 400 V disconnecting module. Type selection Order No. group The compact ET 200pro motor starter can be installed in the ET 200pro station with just a few actions. The integral connector technology results in significant reduction of the wiring overhead. The motor cables can be plugged directly onto the motor starter module. The compact design enables up to eight motor starters to be integrated in a one meter wide station in the field. Standard motor starters 3RK1 304 Direct starter, mechanical -5.S40-4AA. Reversing starter, mechanical -5.S40-5AA. High Feature motor starters 3RK1 304 Direct starter, mechanical -5.S40-2AA. Reversing starter, mechanical -5.S40-3AA. Direct starter, electronic -5.S70-2AA. Electronic current measurement Reversing starter, electronic -5.S70-3AA. Special modules 3RK1 304 The actual current flow with the ET 200pro motor starter is measured electronically. In addition, the motor starter is now available with PROFIenergy functionality. This makes it possible to selectively shut down motors via PROFINET during breaks. Energy-related data such as the motor current can also be integrated into higher-level control systems. Faceplates are offered for PCS7 for visualizing diagnostics data. The evaluation of defined current limits for the parameterizable electron- Maintenance switch module -0HS00-6AA. Safety Local maintenance switch module -0HS00-7AA. 400 V switch-off module -0HS00-8AA. F switch 6ES7 148-4FS. Connection module for F switch 6ES7 194-4DA. SIMATIC ET 200pro © Siemens AG 2012 Two types of frequency converters With the structure of a SIMATIC module, the frequency converter SIMATIC ET200pro FC can be smoothly inserted into the ET200pro system. Two device variants (with and without safety functions) are available for output up to 1.1 kW (1.5 kW with reduced ambient temperature). The communication can be achieved via PROFINET or PROFIBUS. Flexible and fast The integration of the frequency converter in the distributed I/O system SIMATIC ET 200pro offers the following benefits: • Flexibility due to open combination of ET 200pro modules with the frequency converter • 400 V power transmission to downstream converters via jumper plugs up to 25 A In addition, the ET 200pro FC features a multitude of highlights of the SINAMICS drive family: • V/f control and sensor-free frequency adjustment • Energy efficiency through power recovery and reactive power compensation • Feedback of braking energy in the network (the same technology as the SINAMICS-G120 power module PM250) so that braking resistor and braking chopper are eliminated. • Integrated safety functions: functional safety without a costly external protective circuit • Optional Micro Memory Card for automatic download of parameters • Design of the system motor frequency converter with the SIZER (as of Version 2.8) • Parameterization via STARTER (as of Version 4.1, SP1) Frequency converter ET 200pro FC Integrated safety functions The fail-safe design of SIMATIC ET 200pro FC offers comprehensive safety functions, certified in accordance with Category 3 of EN954-1 and SIL 2 of IEC61508. • Safe Torque Off (STO, previously "Safe Standstill") – for protection against an active movement of the drive. • Safe Stop 1 (SS1, previously "Safe Braking Ramp") – for continuous monitoring of a safe braking ramp. • Safely Limited Speed (SLS, previously "Safely Reduced Speed) – for protection against hazardous movements caused by exceeding a speed limit. Neither of the functions "Safe Stop 1" or "Safely Limited Speed" requires a motor encoder or other encoder. The safety functions can be controlled using inputs of the Safety Local maintenance switch module (F-RSM) or the module F Switch PROFIsafe. Frequency converter 1) Order No. group Frequency converter ET 200pro FC with integrated safety functions 6SL3235-0TE21-1SB. Frequency converter ET 200pro FC Standard 6SL3235-0TE21-1RB. 1) Available on request. ET 200pro station with frequency converters and motor starters SIMATIC ET 200pro 49 © Siemens AG 2012 SIMATIC ET 200eco PN Block I/O with IP65/66/67 degree of protection with PROFINET connection SIMATIC ET 200eco PN is the new, rugged and spacesaving block I/O with IP65/66/67 degree of protection. Connection to PROFINET is at 100 Mbit/s. Thanks to its fully-sealed zinc die-cast housing, the ET 200eco PN is mechanically very rugged and resistant to vibrations, dust, oil, or humidity. It can therefore be mounted directly on the machine. The PROFINET connection with a 2-port switch is integrated into every module and allows flexible expansion in line and star topologies. The SIMATIC ET 200eco PN is the product for the current market trend for migrating the I/Os from the control cabinet into the machine gaps. Configuration The sensors and actuators, as well as power and bus are connected via the rugged M12 connection system. The ET 200eco PN is available with two different enclosure designs: • Modules with 4 x M12 connection in a long and narrow design (30 x 200 x 37 mm) • Modules with 8 x M12 connection in a short and wide design (60 x 175 x 37 mm) The modules can be mounted head-on or rotated 90 degrees to the side. ET 200eco PN in wide and narrow design Module range 1) 2) For ET 200eco PN, there is a comprehensive and graded range of modules available. This includes digital modules with up to 16 channels (inputs or outputs), including a parameterizable 8-channel module. Analog modules (current, voltage, resistance thermometer, thermocouple), an IO-Link master module, and a load voltage distributor are also available. General technical specifications Module range Module Transfer rate 100 Mbit/s full duplex Enclosure Parameterizable 1.3 A Zinc die-casting (fully cast) Vibration strength, continuous 20 g 8 x M12 8 x M12 Temperature range -40 °C ... +60 °C 2) 142-6BH. 147-6BG. 8 DI 24 V DC 16 DI 24 V DC 8 DO 24 V DC 16 DO 24 V DC 8 DI/DO 24 V DC Number of input/output channels 8/0 16/0 0/8 0.5 A; 1.3 A; 2 A 0/16 1.3 A Connections 4 x M12, 8 x M12 8 x M12 4 x M12, 8 x M12 Order No. group 6ES7 141-6BF. 141-6BG. 141-6BH. 142-6BF. 142-6BG. 142-6BR. Module range Module 8 AI 8 AI RTD/TC Number of input/output channels 4 U/I and 4 RTD/TC Connections Order no. group 6ES7 4 AO 4 IO-Link (IOLink Master) 1) 24 V DC voltage divider 8 RTD/TC 4 U/I 4 IO-L, 8 DI, 4 DO, (1.3 A) – 8 x M12 8 x M12 4 x M12 8 x M12 1 x 7/8" 4 x M12 144-6KD0. 144-6KD5. 145-6HD. 148-GJA. 148-6CB. NEW 1) For additional information on the IO-Link, see: w w w.s i e m e n s . c o m /i o -l i n k 2) Without IO-Link module and voltage distributor 50 SIMATIC ET 200eco PN © Siemens AG 2012 SIMATIC ET 200eco Digital block I/O with IP65/66/67 degree of protection ET 200eco has a compact, rugged enclosure and is very easy to use. It can be connected to PROFIBUS DP at up to 12 Mbit/s. The plant availability is increased by the integrated T functionality in the connection block. The electronic block can be replaced with the equipment live without the need to interrupt the supply voltage or the bus train. The following diagnostic functions are available for checking the mode of operation of the ET 200eco: Configuration ET 200eco comprises basic modules and two different connection blocks. Selection is possible between M12, 7/8" and ECOFAST: • Bus connection via 2 x M12 and power supply via 2 x 7/8" with 2 rotary coding switches for PROFIBUS address assignment • ECOFAST: 2 x hybrid field bus interface RS 485 with identification connector for the PROFIBUS address setting • BF (bus fault) • SF (system fault) • Encoder and load power supply In the 16 DI version, antivalent sensors can also be connected. The diagnostic data are indicated by LEDs on the module and can be evaluated by software on the PG/PC or by user program of the PLC. For the application and integration of PROFIBUS applications, a compact, perfectly interacting module spectrum of digital I/Os is available. Fail-safe modules enable integration in safety-related systems with SIMATIC Safety Integrated using the PROFIsafe profile over PROFIBUS DP. The pin assignment for the actuators and sensors is modeled on the IP65/67 standardization trends. Module range Module range F modules Basic modules 8 DI 16 DI 8 DO (2 A) 16 DO (0.5 A) 8 DI/8 DO (2 A) 8 DI/8 DO (1.3 A) 4/8 F-DI Qty. input/output channels 8/0 16/0 0/8 0/16 8/8 8/8 4/01) 8/02) Connections 8 x M12 cable glands (for 16 channels with dual assignment) Order No. group 6ES71413BF. Module 6ES71413BH. 6ES71423BF. 6ES71423BH. 6ES71433BH. 6ES71433BH. 6ES71483FA. Connection blocks ECOFAST RS 485 M12, 7/8" ECOFAST Cu M12, 7/8" 6ES71943AA. 6ES71943AA. 1) 2-channel for SIL3 sensors 2) 1-channel for SIL2 sensors General technical specifications Transfer rates 9.6 Kbit/s to 12 Mbit/s Power supply 24 V DC Current input from load circuit 1, up to 55 °C Up to 1 A (according to version) Current carrying capacity of the outputs per channel 0.5/1.3/2 A (according to version) Current input from load circuit 2, up to 55 °C, max. 8A Diagnostic function Group fault display Yes Short-circuit (encoder supply) Module-by-module Load voltage Module-by-module Dimensions (W x H x D) in mm Basic module 210 x 60 x 28 Basic module with ECOFAST 210 x 60 x 54 Basic module with M12, 7/8 210 x 60 x 53 ET 200eco block I/O SIMATIC ET 200eco 51 © Siemens AG 2012 References SIMATIC ET 200S with PROFINET Peterstaler Mineralquellen, Germany – Bottling of mineral water Requirements Peterstaler Mineralquellen GmbH operates bottling plants at two sites in the Black Forest for their mineral water and nonalcoholic beverages. To improve the flexibility and capacity utilization of these two plants, they have been connected together using pipes in a project that is unique in this sector. Great emphasis was placed here on the communication between the two head stations and the substations along the route that had to be suitable for automation and telephone purposes. Solution The decision was in favor of an integrated, distributed solution using PROFINET. A single-mode fiber-optic network based on Ethernet (14 km distance) forms the backbone for the communication for the automation systems and the Voice-over-IP between the two sites. The mainstays of the automation solution are PROFINET-capable S7-300 controllers that are connected to the fiber-optic backbone via Switches. The actuators and sensors of the field level (such as valve terminals) are connected to the integrated PROFINET interface via SIMATIC ET 200S distributed I/O devices. 52 References Benefits Thanks to the integral PROFINET functionality in the controllers of the S7-300 range as well as the SIMATIC ET 200S I/O, the automation devices could be directly connected to the Ethernet-based single-mode network. When programming with SIMATIC STEP 7, there is no distinction between accessing an I/O device such as SIMATIC ET 200S over PROFIBUS or PROFINET, so the expertise gained by the customer with PROFIBUS was safeguarded. The important advantage of PROFINET over standard Ethernet according to the customer are the cycle times of between 5 ms and 10 ms that can be achieved over the real-time channel without which the extremely demanding closed-loop control tasks of this application would not have been possible over large distances. "We are very satisfied with this solution: Transporting the mineral water over the hill has been problem-free since then. Transport by truck became unnecessary and this reduced the associated pollutant emission, which in turn was evaluated very positively in our current ISO 14001 environment protection audit." Wolfgang Sum, Manager © Siemens AG 2012 SIMATIC ET 200S COMPACT Meyer Burger AG, Switzerland – Manufacturing and processing of materials Requirements Meyer Burger AG has over 50 years of experience in cutting hard and brittle materials and special crystals such as silicon and sapphire. The global sales and service network of Meyer Burger has a separate subsidiary in China and Japan as well as service centers in Germany and the Philippines. The main industries are the photovoltaic, semiconductor and optical and ceramics industries. More than 3,500 systems have been installed worldwide. Hard and brittle materials have to be cut faster, more accurately and with less loss of material. This places stringent demands on the control system and the I/O: Compact size, fast response, reduced wiring outlay and modular construction of machines. Solution To meet these requirements, Meyer Burger relies on the compact distributed I/O ET 200S COMPACT. Thanks to their high channel density, it was not necessary to expand the stations. Add-on terminals were also used to enable 3-wire connection without the need for additional terminal blocks. This saves space and time during wiring up. The existing bus system was PROFIBUS DP, so this was also used for the new solution. Benefits The use of ET 200S COMPACT provides several benefits: The signals of the different sensors and switches can now be bundled and evaluated by the existing PROFIBUS. Complete preassembly (wiring) of the modules means that on final installation only the bus cable has to be connected. Time-consuming wiring of modules in the control cabinet is therefore reduced. "By using ET 200S COMPACT, we can acquire control variables on our machines decentralized and transfer them to the controller over PROFIBUS. Fewer signals therefore have to be routed to the control cabinet. This reduces the wiring costs and increases our flexibility considerably. We can therefore reduce throughput time at final assembly." Dr. Urs Schönholzer, Head of Development References 53 © Siemens AG 2012 SIMATIC ET 200M Turgai-Petroleum, Canada – Remote control for oil production Requirements Turgai-Petroleum AG with headquarters in Kysyl-Orda is a joint venture between the Russian LUKOIL Overseas and the Canadian Petro Kazakhstan. LUKOIL is one of the leading worldwide corporations in the oil and gas sector and is mainly active in the exploration and production of oil and gas as well as the production and marketing of mineral oil products and petrochemicals. The capacity of their production plants in Russia alone is 41.8 million tons of oil per annum. Petro Kazakhstan is one of the 100 largest oil producers. The Canadian company has specialized in oil-rich Kazakhstan, produces 150,000 barrels per day, and operates a refinery in the Central Asian country. Energotechservice GmbH with headquarters in Almaty, Siberia, was tasked with the data acquisition and remote control of oil production. The focus here was on integration in the existing system and user-friendly features as well as their consistent further development. Further requirements included implementation of data transmission over wireless channels and integration in the existing telemechanical system. 54 References Solution The automatic control system for the technological processes of the oil and gas sector is based on a system for telemetric data acquisition and remote control. For Turgai-Petroleum, 120 probes were optimized using automation. Due to the environmental conditions, SIMATIC ET 200M modules for use in hazardous areas were used. They are of a particularly rugged and intrinsically-safe construction. This I/O is based on the same principle as the S7 controllers, so it interacts well with the SIMATIC S7-300 components used. Benefits Due to the modular structure of ET 200M, the application was implemented with the smallest possible number of components. The redundant structure and the ability to make changes to the configuration during normal operation has increases the availability of the plant significantly. Modules can now be replaced during normal operation and downtimes are reduced to a minimum. By using STEP 7, 50 to 70% of the engineering costs and time could be saved. Overall, the stability of the process and the productivity has significantly increased. Drives can now be easily controlled, either remotely or locally as required. © Siemens AG 2012 SIMATIC ET 200iSP Norr Systems, Singapore – cargo and ballast system Requirements The loading and unloading of liquids from tanks is a great challenge. The emphasis on safety is thereby of greatest importance. Especially with hazardous and flammable materials, the proper loading and unloading procedure is an important task of the freight master. Thus the valve control has become the most important system within the freight distribution. The valve control system must be constructed from reliable components. Any error in this system can result in undesired consequences for the safety of both the ship and the crew. Solution NORR SYSTEMS has developed an interesting control system which uses hydraulic high-pressure and low-pressure valves and integrates Siemens automation products. Considered from the mechanical perspective, an intrinsically safe lowpressure way valve increases the reliability (the purity of the oil is less significant than with a high-pressure way valve) and simplifies the maintenance. Seen from the electronic viewpoint, the SIMATIC controls from Siemens together with the intrinsically safe distributed I/O SIMATIC ET 200iSP and PROFIBUS form a good solution for communication between hazardous (Zone 1) and non-hazardous areas. The electric control and response signals for the valve control system are carried out via PROFIBUS. The expense for the ship installation was minimized and in the software specification many additional functions for error diagnostics of the entire system could be programmed. It was even more important that thanks to the Siemens solution the number of components used in the entire system could be reduced and the availability of the entire system could be increased. Benefits The main benefit of this integrated hydraulic valve control system is that it completely fulfills the special requirements of the customer for both user friendliness and simple maintenance. The SIMATIC ET 200iSP allows for extremely easy establishment of communication between the hazardous and safe areas and the avoidance of a Zener barrier. The customer is highly satisfied with this system, since it supports the ship's crew in the loading and unloading of freight in one of the offshore oil fields. References 55 © Siemens AG 2012 SIMATIC ET 200pro with Safety Integrated and PROFINET Volkswagen Nutzfahrzeuge, Germany – Vibrating roller test bed Requirements Volkswagen Nutzfahrzeuge (VWN), an autonomous brand of the Volkswagen corporation has installed the final noise test in the transporter works in Hanover in the workshop hall. Now the commercial vehicle business is operating a vibrating roller test bed in its works in Hanover in cooperation with the "Automation Initiative of the German Automotive Industry" (AIDA). The customer's requirements were extensive: The vibrating roller test bed had to be linked into the existing network structure (PROFINET); fail-safe communication was just as important as a reduction in training costs. The use of distributed I/O was also demanded. Solution The distributed I/O had to be installed in the support structure of the test bed, in a compact space, close to the vibration dampers. Therefore the only solution was a cabinet-free solution of extremely high ruggedness and industrial compatibility, which is why SIMATIC ET 200pro was used. 56 References An S7-400F controller was used which ensured fail-safe communication over PROFINET. Apart from the cabinet-free SIMATIC ET 200pro, the SIMATIC ET 200S – which was installed in the control cabinet alongside the controller – was also used as distributed I/O. Both distributed I/O systems are in a standard but fail-safe configuration. A PROFINET-capable SCALANCE X208pro switch with IP65 degree of protection distributes incoming and outgoing data. Benefits Use of SIMATIC ET 200pro resulted in a number of advantages: Costs were saved thanks to standardization and optimization of the spare parts inventory. The reduction in training costs for maintenance and service personnel was also satisfied. Due to the ability to replace electronic modules during operation (hot swapping), high availability was achieved for the plant. There was also a reduction in the installation and wiring costs for the safety-related part of the plant. © Siemens AG 2012 SIMATIC ET 200eco PN Stihl Andreas AG & Co KG, Germany – Production of chain saws Requirements Stihl in Waiblingen/Germany is one of the leading manufacturers of chain saws and equipment for greenspace and forest maintenance. Stihl chain saws combine innovative technology, high performance, optimum ergonomics and low weight, mainly through different equipment variants for any application. This requires modern and highly flexible manufacturing plants. With proprietary equipment production and highly qualified and specialized personnel, Stihl is able to equip its own manufacturing and assembly facilities. That is why the automation specialists are extremely interested in innovative and lasting automation solutions. To simplify handling and to make maintenance/adjustment as efficient as possible, a uniform solution with a minimum of engineering tools is required. To protect investments on a long-term basis, Stihl places great emphasis on long-lasting solutions. Solution In the newly installed assembly line (50 m long), different chain saw variants are produced flexibly, from the chassis through the assembly up to final inspection and testing. At the beginning, a manufacturing data set consisting of up to 20 variants is assigned to each mounting structure. An uncoded RFID chip which stores the manufacturing data is attached to the mounting structure for this purpose. During the entire manufacturing process, the mounting structure is uniquely identified at RFID reading stations and is read in directly at the machine via ET 200eco PN IO-Link Master. Furthermore, the production steps are visualized and controlled at mobile panels (SIMATIC Mobile Panel 277 IWLAN) throughout the entire assembly line via Industrial Wireless LAN (IWLAN). Benefits Through the use of the flexible and rugged ET 200eco PN, the data can be bundled direct at the RFID reader and, via standard PROFINET protocols, sent direct to the CPU for further processing. Integrated tools, such as the Port Configurator Tool (PCT) for IO-Link, have also made maintenance very easy, since replacement IO-Link Master modules receive their addresses without any configuration overhead and are then immediately ready for operation, with the result that "the modules of SIMATIC ET 200eco PN do not have to be addressed at all, neither during installation nor during replacement in the event of a failure", says Michael Muerdter, automation expert at Stihl. Faults are detected at an early stage via the integrated diagnostics, indicated on the visual display device and remedied before any significant failure occurs. Costs can thus be reduced in the long term and downtimes minimized. References 57 © Siemens AG 2012 SIMATIC ET 200eco Veronesi, Italy – Animal feed manufacturer modernizes basic materials infeed Requirements One of the largest European manufacturers of animal feeds, Veronesi S.p.A, Italy, was looking for an efficient solution for modernized automation of their basic materials infeed. Materials infeed is the critical point in production for the animal feed manufacturer. When no products continue to come in, the entire plant is idle. Thus it was important that production continues without restriction. The safety regulations for installations in a dust-filled atmosphere must also be satisfied. The greatest challenge, however, was presented by selection of the technical configuration: All sensors and actuators had to be connected to the distributed I/O over the shortest possible connections; this demanded a cabinet-free configuration. Solution The Swiss system integrator ASE-Bühler AG developed the new plant concept – taking into account the plant philosophy of Veronesi: All subsystems are subdivided into individual sectors. The materials infeed too. This was automated by means of a SIMATIC S7-400 controller. It replaced the aging relay control. The special feature of the new plant is the PROFIBUS architecture. Four PROFIBUS lines run from the S7-400 PLC into the concrete towers containing the silos. A total of 150 SIMATIC ET 200eco stations are connected to the four bus lines which were installed without a cabinet directly in the plant. Control boxes were only required for the repeaters that were installed to support PROFIBUS branches. The connections were implemented using the standardized ECOFAST system with data and power supplied along the same cable. 58 References Benefits Commissioning of the fully automated complete solution was problem-free and implementation was possible during normal operation of the plant. The wiring over the ECOFAST connections was extremely easy, so the retrofit was completed quickly. The new solution supported a cost-saving bus architecture with cabinet-free distributed I/O as well as increased transparency in the automation system. Since the entire solution originates from Siemens, the training time for the maintenance personnel was reduced. In the event of a disturbance, they merely need to contact a partner at Siemens. © Siemens AG 2012 Step into the world of SIMATIC This brochure has given you an initial overview of the extensive SIMATIC portfolio for process automation – and of the advantages for you as a machine builder and plant operator. Further information on the individual families of systems can be found in the Internet sites listed below. S I M A T I C SIMATIC is a principal component of Totally Integrated Automation, the comprehensive and integrated range of products and systems for automation: www.siemens.com/tia SIMATIC – the leading automation system for industry: www.siemens.com/simatic Get to know the SIMATIC consistency through its system features: www.siemens.com/simatic-system-features SIMATIC PCS 7 SIMATIC Controller SIMATIC ET 200 The powerful, scalable process control system for all sectors Powerful controller based on various hardware platforms The distributed, modular I/O system for all requirements www.siemens.com/simatic-pcs7 www.siemens.com/simatic-controller www.siemens.com/simatic-et200 SIMATIC Software SIMATIC Technology SIMATIC HMI Industrial software for maximum efficiency in every phase of an automation project The comprehensive range of products for performing technological tasks The complete range for operator control and monitoring www.siemens.com/simatic-software www.siemens.com/simatic-technology www.siemens.com/simatic-hmi SIMATIC PC-based Automation SIMATIC IT SIMATIC NET Comprehensive range of hardware and software products for PC-based Automation The basis for customer-specific, integrated MES solutions The extensive range of products and systems for industrial communication www.siemens.com/pc-based-automation www.siemens.com/simatic-it www.siemens.com/simatic-net SIMATIC Safety Integrated SIMATIC Sensors SIPLUS extreme The seamless system for safety technology that integrates smoothly and completely into standard automation Sensors for an enormous variety of requirements in the production industry Products for industrial applications in harsh ambient conditions and extreme environments www.siemens.com/simatic-safety-integrated www.siemens.com/simatic-sensors www.siemens.com/siplus-extreme SIMATIC Overview 59 © Siemens AG 2012 Get more information Distributed I/O: www.siemens.com/et200 PROFINET: www.siemens.com/profinet SIMATIC Safety Integrated: www.siemens.com/f-cpu Totally Integrated Automation: www.siemens.com/totally-integrated-automation SIPLUS extreme – hardening and conditioning: www.siemens.com/siplus-extreme SIMATIC Guide Manuals: www.siemens.com/simatic-docu Information material to download: www.siemens.com/simatic/printmaterial Service & Support: www.siemens.com/automation/support SIMATIC partners: www.siemens.com/automation/partner Industry Mall for electronic ordering: www.siemens.com/industrymall Siemens AG Industry Sector Industrial Automation Systems Postfach 48 48 90026 NÜRNBERG GERMANY www.siemens.com/automation Subject to change without prior notice PDF (6ZB5310-0MF02-0BA8) MP.R1.AS.0000.20.3.02 BR 1112 60 En Produced in Germany © Siemens AG 2012 The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines Signing Date : 2013:05:16 09:59:55+02:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, Export XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Format : application/pdf Title : SIMATIC ET 200 - For distributed automation solutions Creator : I IA AS S ID, I IA CC PRI Description : Brochure Subject : SIMATIC ET 200, Distributed I/O, Totally Integrated Automation, TIA, 6ZB5310-0MF02-0BA8, Brochure • November 2012 Rights : © Siemens AG Create Date : 2012:11:26 11:30:54+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:05:16 09:59:57+02:00 Metadata Date : 2013:05:16 09:59:57+02:00 Producer : Acrobat Distiller 9.5.2 (Windows) Keywords : SIMATIC ET 200; Distributed I/O; Totally Integrated Automation; TIA; 6ZB5310-0MF02-0BA8; Brochure • November 2012 Document ID : uuid:8047b112-c06f-472d-8865-aefc688b89aa Instance ID : uuid:1350cc70-3593-4f56-bc11-414d5666c7e1 Marked : True Has XFA : No Page Count : 60 Page Layout : SinglePage Author : I IA AS S IDEXIF Metadata provided by EXIF.tools