CC3 Cc E

User Manual: CC3

Open the PDF directly: View PDF PDF.
Page Count: 25

DownloadCC3 Cc E
Open PDF In BrowserView PDF
1

CC-E

Insulation type DC-DC converter

Low Voltage Directive

■ Features

R: Horizontally-mounted SMD type
FS Vertically-mounted SIP type

Symbol for number of outputs
S: Single output, D: Dual outputs

Nominal output voltage
03: 3.3V, 05: 5V, 12: 12V

Nominal input voltage
05: 5V, 12: 12V, 24: 24V, 48: 48V

●5-side metal-shielded low noise design
●Lightweight design with no resin filled up
●Supports DIP insertion,SMD mounting and SIP vertical insertion (3W products)
●Approved by UL60950-1, CSA C22.2 No.60950-1
(C-UL), and EN60950-1 (NEMKO)

Maximum output power
1R5: 1.5W, 3: 3W, 6:6W
10: 10W, 15: 15W, 25: 25W

Representing series name by
combination with "-E"at the end

■ Conformity to RoHS Directive

■ Applications

This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame retar dants, PBB and PBDE, have not been used, except for
exempted applications.

■ Product Line up

1.5W

DIP type

SMD type

Model name
(output voltage: 5V)

SIP type Output current

DIP type

SMD type

Model name
(output voltage: 12V/15V)

SIP type Output current

DIP type

SMD type

Model name
(output voltage: ±12V/±15V)

SIP type Output current

DIP type

SMD type

SIP type

0.4A CC1R5-0503SF-E CC1R5-0503SR-E

-

0.3A CC1R5-0505SF-E CC1R5-0505SR-E

-

0.125A (0.1A) CC1R5-0512SF-E CC1R5-0512SR-E

-

0.06A (0.05A) CC1R5-0512DF-E CC1R5-0512DR-E

-

12V 0.4A CC1R5-1203SF-E CC1R5-1203SR-E

-

0.3A CC1R5-1205SF-E CC1R5-1205SR-E

-

0.125A (0.1A) CC1R5-1212SF-E CC1R5-1212SR-E

-

0.06A (0.05A) CC1R5-1212DF-E CC1R5-1212DR-E

-

24V 0.4A CC1R5-2403SF-E CC1R5-2403SR-E

-

0.3A CC1R5-2405SF-E CC1R5-2405SR-E

-

0.125A (0.1A) CC1R5-2412SF-E CC1R5-2412SR-E

-

0.06A (0.05A) CC1R5-2412DF-E CC1R5-2412DR-E

-

48V 0.4A CC1R5-4803SF-E CC1R5-4803SR-E

-

0.3A CC1R5-4805SF-E CC1R5-4805SR-E

-

0.125A (0.1A) CC1R5-4812SF-E CC1R5-4812SR-E

-

0.06A (0.05A) CC1R5-4812DF-E CC1R5-4812DR-E

-

0.8A CC3-0503SF-E CC3-0503SR-E CC3-0503SS-E 0.6A

CC3-0505SF-E

CC3-0505SR-E CC3-0505SS-E 0.25A (0.2A) CC3-0512SF-E

CC3-0512SR-E CC3-0512SS-E 0.125A (0.1A) CC3-0512DF-E

CC3-0512DR-E CC3-0512DS-E

12V 0.8A CC3-1203SF-E CC3-1203SR-E CC3-1203SS-E 0.6A

5V
3W

Model name
(output voltage: 3.3V)
Output current

warranty

Shape F: Horizontally-mounted DIP type

High accuracy of ± 3% in output voltage (10W of
lower single output)

5V

5

■ Model-naming method
CC 3 - 05 05 S F -E

●Mounting area halved compared to existing products
●Nonuse of tantalum capacitor or aluminum electrolytic capacitor
●Remote On/Off function incorporated in all series of
products

Output Input
power voltage

EN60950-1

UL60950-1/
CSA C22.2 No.60950-1

Y
E
A
R
S

CC3-1205SF-E

CC3-1205SR-E CC3-1205SS-E 0.25A (0.2A) CC3-1212SF-E

CC3-1212SR-E CC3-1212SS-E 0.125A (0.1A) CC3-1212DF-E

CC3-1212DR-E CC3-1212DS-E

0.6A

CC3-2405SF-E

CC3-2405SR-E CC3-2405SS-E 0.25A (0.2A) CC3-2412SF-E

CC3-2412DR-E CC3-2412DS-E

48V 0.8A CC3-4803SF-E CC3-4803SR-E CC3-4803SS-E 0.6A

CC3-4805SF-E

CC3-4805SR-E CC3-4805SS-E 0.25A (0.2A) CC3-4812SF-E

CC3-2412SR-E CC3-2412SS-E 0.125A (0.1A) CC3-2412DF-E
CC3-4812SR-E
0.125A (0.1A) CC3-4812DF-E

5V

24V 0.8A CC3-2403SF-E CC3-2403SR-E

-

CC3-4812DR-E CC3-4812DS-E

1.2A CC6-0503SF-E CC6-0503SR-E

-

1A

CC6-0505SF-E

CC6-0505SR-E

-

0.5A (0.4A) CC6-0512SF-E

CC6-0512SR-E

-

0.25A (0.2A) CC6-0512DF-E

CC6-0512DR-E

-

12V 1.2A CC6-1203SF-E CC6-1203SR-E

-

1.2A

CC6-1205SF-E

CC6-1205SR-E

-

0.5A (0.4A) CC6-1212SF-E

CC6-1212SR-E

-

0.25A (0.2A) CC6-1212DF-E

CC6-1212DR-E

-

24V 1.2A CC6-2403SF-E CC6-2403SR-E

-

1.2A

CC6-2405SF-E

CC6-2405SR-E

-

0.5A (0.4A) CC6-2412SF-E

CC6-2412SR-E

-

0.25A (0.2A) CC6-2412DF-E

CC6-2412DR-E

-

48V 1.2A CC6-4803SF-E CC6-4803SR-E

-

1.2A

CC6-4805SF-E

CC6-4805SR-E

-

0.5A (0.4A) CC6-4812SF-E

CC6-4812SR-E

-

0.25A (0.2A) CC6-4812DF-E

CC6-4812DR-E

-

2.5A CC10-0503SF-E CC10-0503SR-E

-

2A

CC10-0505SF-E CC10-0505SR-E

-

0.8A (0.64A) CC10-0512SF-E CC10-0512SR-E

-

0.4A (0.32A) CC10-0512DF-E CC10-0512DR-E

-

12V 2.5A CC10-1203SF-E CC10-1203SR-E

-

2A

CC10-1205SF-E CC10-1205SR-E

-

1A (0.8A) CC10-1212SF-E CC10-1212SR-E

-

0.45A (0.36A) CC10-1212DF-E CC10-1212DR-E

-

24V 2.5A CC10-2403SF-E CC10-2403SR-E

-

2A

CC10-2405SF-E CC10-2405SR-E

-

1A (0.8A) CC10-2412SF-E CC10-2412SR-E

-

0.45A (0.36A) CC10-2412DF-E CC10-2412DR-E

-

48V 2.5A CC10-4803SF-E CC10-4803SR-E

-

2A

CC10-4805SF-E CC10-4805SR-E

-

1A (0.8A) CC10-4812SF-E CC10-4812SR-E

-

0.45A (0.36A) CC10-4812DF-E CC10-4812DR-E

15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E

-

3A

CC15-2405SF-E CC15-2405SR-E

-

-

-

-

-

-

-

-

-

25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E

-

5A

CC25-2405SF-E CC25-2405SR-E

-

-

-

-

-

-

-

-

-

6W

5V
10W

-

web171023
・All specifications are subject to change without notice.

2

CC1R5-E
CC1R5-E Specifications
MODEL CC1R5-0503Sx-E CC1R5-0505Sx-E
CC1R5-0512Sx-E
CC1R5-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1) %
71
77
80
79
Current (typ)
(*1) A
0.372
0.390
0.375
0.380
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40°
C to +50°
C)
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
3.2
Mechanical
Size (W x H x D)
mm
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E
CC1R5-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1) %
73
78
82
81
Current (typ)
(*1) A
0.151
0.160
0.152
0.154
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40°
C to +50°
C)
Max Power Total Regulation (max) (*4) %
3
±5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4 - 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
3.2
Mechanical
Size (W x H x D)
mm
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

CC1R5-E

MODEL CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E
CC1R5-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
72
77
81
79
Current (typ)
(*1) A
0.076
0.081
0.077
0.079
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40°
C to +50°
C)
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
3.2
Mechanical
Size (W x H x D)
mm
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E
CC1R5-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1) %
70
76
80
79
Current (typ)
(*1) A
0.039
0.041
0.039
0.040
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40°
C to +50°
C)
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Between input terminal and output terminal: 500VDC, 50MΩ min
Isolation Resistance
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
3.2
Mechanical
Size (W x H x D)
mm
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

3

4

CC1R5-E
Outline Drawing
CC1R5-xxxxxF-E (DIP type)
16.6±0.2

Recommended measurements for
mounting board

13.08

12.7
16.51

5
7-0.3×0.6

2-ø1.5 (land diameter ø2.5)

6
7
a

1
b

3.5

2

7-ø1.0 (land diameter ø2.0)

16.51

1.0
0.5

b
4

2.7

a

Outer shape of
product

0.5

1.905

2.54 5.08 2.54

(3.22)

12.7

a
3

7.62

2.54
(3.22)

1.905

10.16

3.5

t=0.3

2.54 5.08 2.54

2.92

14.605

7.62

8.5max.

4.0

Shape/Dimensions

b

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

2.7

CC1R5-xxxxxR-E (SMD type)
16.6±0.2

Recommended measurements for
mounting board
(3.22)

1.8

2.54
(3.22)

1.8

2.54 5.08 2.54

(13.38)

Coplanarity: 0.1 or lower

19.81

Outer shape of
product

1.2

16.51

10.16

t=0.3

7.62

8.8max.

4.0

Shape/Dimensions

3.2

2

5
7-0.3×0.6

6

(3.22)

1

7

1

7

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

3

No.1
No.2
No.3
No.4
No.5
No.6
No.7

TRM
–Vout

4 NC

+Vin

+Vin
RC
–Vin
NC
–Vout
TRM
+Vout

7

1

6
RC

5
2
4

3

–Vin

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.

Terminal connections

+Vout
TRM
COM
–Vout

Load

–Vin

5
2

+Vout

CC1R5-xxxxDx-E
Load

RC

Terminal connections
Load

6

3.2

22.0

Connection diagram
CC1R5-xxxxSx-E
+Vin

15.6

2.54 5.08 2.54

4

7.62

3

No.1
No.2
No.3
No.4
No.5
No.6
No.7

+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout

CC3-E(DIP/SMD)

5

CC3-E Specifications
MODEL CC3-0503Sx-E
CC3-0505Sx-E
CC3-0512Sx-E
CC3-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1) %
73
77
82
81
Current (typ)
(*1) A
0.723
0.779
0.732
0.741
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2)
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Vibration
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
4.5
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC3-1203Sx-E
CC3-1205Sx-E
CC3-1212Sx-E
CC3-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1) %
74
79
82
81
Current (typ)
(*1) A
0.297
0.316
0.305
0.309
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
4.5
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

CC3-E(DIP/SMD)

MODEL CC3-2403Sx-E
CC3-2405Sx-E
CC3-2412Sx-E
CC3-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
73
78
82
81
Current (typ)
(*1) A
0.151
0.160
0.152
0.154
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
4.5
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC3-4803Sx-E
CC3-4805Sx-E
CC3-4812Sx-E
CC3-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1) %
73
79
81
80
Current (typ)
(*1) A
0.075
0.079
0.077
0.078
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Vibration
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
4.5
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

6

CC3-E(DIP/SMD)

7

Outline Drawing
CC3-xxxxxF-E (DIP type)
16.6±0.2

Recommended measurements for mounting board

2.92

20.32

22.86

2.54

a

2-ø1.5 (land diameter ø2.5)

2

5
6
7

1
b

22.86

1.0
0.5

4

7.62

3

3.5

b

7-0.3× 0.6

(3.22)

2.7

a

7-ø1.0 (land diameter ø2.0)

0.5

17.78

2.54 5.08 2.54

2.54
(3.22)

2.54

Outer shape of product

2.54 5.08 2.54

13.08

17.78

10.16

3.5

t=0.3

7.62

8.5max.

4.0

Shape/Dimensions

b

2.7
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

a

CC3-xxxxxR-E (SMD type)
16.6±0.2

(3.22)

Recommended measurements for mounting board

7.62

2.54 5.08 2.54

Coplanarity: 0.1 or lower

Outer shape of product

1.2

22.86

(13.38)

t=0.3

10.16

8.8max.

4.0

Shape/Dimensions

26.16

1.8

1.8

3.2

22.0

3.2

4

2

5
7-0.3× 0.6

6

1

(3.22)

2.54 5.08 2.54

3

7.62

2.54
(3.22)

28.4

7

Connection diagram
CC3-xxxxSx-E
+Vin

7

–Vin

5
2
3

TRM
–Vout

4 NC

CC3-xxxxDx-E
+Vin

+Vin
RC
–Vin
NC
–Vout
TRM
+Vout

7

1

6
RC

5
2
4

3

–Vin

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.

Terminal connections

+Vout
TRM
COM
–Vout

Load

RC

No.1
No.2
No.3
No.4
No.5
No.6
No.7

Load

6

Terminal connections

+Vout

Load

1

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

No.1
No.2
No.3
No.4
No.5
No.6
No.7

+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout

CC3-E(SIP)

8

CC3-E Specifications
MODEL CC3-0503SS-E
CC3-0505SS-E
CC3-0512SS-E
CC3-0512DS-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1) %
73
77
82
81
Current (typ)
(*1) A
0.723
0.779
0.732
0.741
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.67
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
7
Mechanical
Size (W x H x D)
mm
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

MODEL
CC3-1205SS-E
CC3-1212SS-E
CC3-1212DS-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1) %
79
82
Current (typ)
(*1) A
0.316
0.305
VDC
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
3
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
7
Mechanical
Size (W x H x D)
mm
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

・All specifications are subject to change without notice.

CC3-E(SIP)

MODEL CC3-2403SS-E
CC3-2405SS-E
CC3-2412SS-E
CC3-2412DS-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
73
78
82
81
Current (typ)
(*1) A
0.151
0.160
0.152
0.154
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.67
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
7
Mechanical
Size (W x H x D)
mm
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

MODEL
CC3-4803SS-E
CC3-4805SS-E
CC3-4812DS-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1) %
73
79
82
Current (typ)
(*1) A
0.075
0.079
0.076
VDC
3.3
5
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation (Within input voltage range) mV
20
80
Maximum Load Regulation (0-100% load) (*3) mV
40
600
Output
Temperature Coefficient
80mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
7
Mechanical
Size (W x H x D)
mm
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

・All specifications are subject to change without notice.

9

CC3-E(SIP)

10

Outline Drawing
CC3-xxxxxS-E (SIP type)
Shape/Dimensions

17.9

9.2

4

P

P

P

P

2P

P

P

P

P

22.86

(0.5)

2.47

6

17.78

P=2.54

27.8
4

5

7

8

9 10

a

27.8

0.5

3

9.2

2

t=0.25

5.01

Recommended measurements for mounting board

a
1

0.5

3.5

(0.5)
4.1
2.47

1(t=0.3)

2.47

4

22.86

2.47

17.78

2-ø1.5 (land diameter ø2.5)

P

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

P

P

P

2P

P

P

P

6.0

Internal parts mounting space

9.2

P=2.54

9-ø0.8 (land diameter ø2.0)

Connection diagram
CC3-xxxxSS-E

Load

–Vin

+Vin

+Vin

10

RC

9

TRM

8

–Vout

+Vin

7

Terminal connections
COM

+Vin

5

+Vout
NC
NC
–Vout
TRM
NC
RC
–Vin
+Vin
+Vin

COM

–Vin

4

No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9
No.10

+Vout

RC

3

TRM

2

–Vout

Terminal connections

+Vout
1

CC3-xxxxDS-E

1

2

3

4

5

7

8

9

10

Load Load

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)

・All specifications are subject to change without notice.

No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9
No.10

+Vout
COM
COM
–Vout
TRM
NC
RC
–Vin
+Vin
+Vin

11

CC6-E
CC6-E Specifications
MODEL CC6-0503Sx-E
CC6-0505Sx-E
CC6-0512Sx-E
CC6-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1) %
76
79
82
Current (typ)
(*1) A
1.042
1.266
1.463
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
1.200
1.000
0.500
0.400
0.250
0.200
Maximum Power
(*2) W
3.96
5
6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
5.8
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC6-1203Sx-E
CC6-1205Sx-E
CC6-1212Sx-E
CC6-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1) %
78
82
85
Current (typ)
(*1) A
0.423
0.610
0.588
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
1.200
0.500
0.400
0.250
0.200
Maximum Power
(*2) W
3.96
6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
5.8
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

CC6-E

MODEL CC6-2403Sx-E
CC6-2405Sx-E
CC6-2412Sx-E
CC6-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
77
81
87
86
Current (typ)
(*1) A
0.214
0.309
0.287
0.291
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
1.200
0.500
0.400
0.250
0.200
Maximum Power
(*2) W
3.96
6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
5.8
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC6-4803Sx-E
CC6-4805Sx-E
CC6-4812Sx-E
CC6-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1) %
77
81
86
Current (typ)
(*1) A
0.107
0.154
0.145
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
1.200
0.500
0.400
0.250
0.200
Maximum Power
(*2) W
3.96
6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
5.8
Mechanical
Size (W x H x D)
mm
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

12

13

CC6-E
Outline Drawing
CC6-xxxxxF-E (DIP type)
21.1±0.2

Recommended measurements for mounting board
20.32

2.63

8.5max.

4.0

Shape/Dimensions

10.16

5.08

17.78

15.24

17.87

3.5

t=0.3

5.08

Outer shape of product

7-ø1.0 (land diameter ø2.0)

a

b

2.7

0.5

2.54

4
5.08

3
7-0.3×0.6
2

22.86

1.0

5

a

5.08

10.16

2-ø1.5 (land diameter ø2.5)

3.5

b

0.5

5.08 (2.93)

2.54

5.08

22.86

2.7

5.08

6

(2.93)

1

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

7
b

a

CC6-xxxxxR-E (SMD type)
21.1±0.2

(2.93)

Recommended measurements for mounting board

Outer shape of product

3

4
7-0.3×0.6

3.2

22.0

3.2

28.4

5

10.16

5.08

2

(2.93)

5.08
5.08

1.8

5.08

5.08 (2.93)

1.8

1.2

(18.17)

Coplanarity: 0.1 or lower

10.16

22.86
26.16

15.24

t=0.3

5.08

8.8max.

4.0

Shape/Dimensions

5.08

6
1

7

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

Connection diagram
CC6-xxxxSx-E
+Vin

7

–Vin

5
2
3

–Vout

4 NC

+Vin

+Vin
RC
–Vin
NC
–Vout
TRM
+Vout

Terminal connections
7

1

6
RC

5
2
4

3

–Vin

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.

+Vout
TRM
COM
–Vout

Load

RC

TRM

Load

6

No.1
No.2
No.3
No.4
No.5
No.6
No.7

CC6-xxxxDx-E
Load

1

Terminal connections
+Vout

No.1
No.2
No.3
No.4
No.5
No.6
No.7

+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout

14

CC10-E
CC10-E Specifications
MODEL CC10-0503Sx-E CC10-0505Sx-E
CC10-0512Sx-E
CC10-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1) %
84
83
Current (typ)
(*1) A
1.964
2.381
2.286
2.313
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
2.500
2.000
0.800
0.640
0.400
0.320
Maximum Power
(*2) W
8.25
10
9.6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
10
Mechanical
Size (W x H x D)
mm
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC10-1203Sx-E CC10-1205Sx-E
CC10-1212Sx-E
CC10-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1) %
84
86
88
86
Current (typ)
(*1) A
0.318
0.969
1.136
1.047
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
2.500
2.000
1000
800
450
360
Maximum Power
(*2) W
8.25
10
12
10.8
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
10
Mechanical
Size (W x H x D)
mm
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

CC10-E

MODEL CC10-2403Sx-E CC10-2405Sx-E
CC10-2412Sx-E
CC10-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
84
86
87
86
Current (typ)
(*1) A
0.409
0.484
0.575
0.523
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
2.500
2.000
1.000
0.800
0.450
0.360
Maximum Power
(*2) W
8.25
10
12
10.8
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
10
Mechanical
Size (W x H x D)
mm
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC10-4803Sx-E CC10-4805Sx-E
CC10-4812Sx-E
CC10-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1) %
84
86
88
86
Current (typ)
(*1) A
0.205
0.242
0.284
0.262
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
2.500
2.000
1.000
0.800
0.450
0.360
Maximum Power
(*2) W
8.25
10
12
10.8
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4) %
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Operating Ambient Humidity
Environment
% RH
5-95 (the conditions of maximum 38°
C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
10
Mechanical
Size (W x H x D)
mm
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.

15

16

CC10-E
Outline Drawing
CC10-xxxxxF-E (DIP type)
Recommended measurements for mounting board
30.48

25.4

Outer shape of
product

5.08 5.08 5.08

18.62

3.5

t=0.3

15.24

4.0

8.5max.

22.6±0.2

10.16 3.38

Shape/Dimensions

7-ø1.0 (land diameter ø2.0)

35.56

25.4

5.08

2-ø1.5 (land diameter ø2.5)

0.5

5.08

a

4
5
6

7-0.3×0.6
1

b

a

7

b

2.7

0.5

(3.68) 10.16

2

2.7

3.5

3

b

5.08 5.08 5.08

5.08
(3.68)

35.56

a

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

1.0

CC10-xxxxxR-E (SMD type)
Shape/Dimensions

Recommended measurements for mounting board

1.8

3

4

(3.68) 10.16

2

5
6

7-0.3×0.6
1

3.2

5.08 5.08 5.08

5.08
(3.68)

1.8

7

CC10-xxxxDx-E
7

3

TRM

No.1
No.2
No.3
No.4
No.5
No.6
No.7

–Vout

4 NC

+Vin

+Vin
RC
–Vin
NC
–Vout
TRM
+Vout

7

1

6
RC
–Vin

5
2
4

3

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.

Terminal connections

+Vout
TRM
COM
–Vout

Load

–Vin

5
2

Terminal connections

+Vout
Load

6
RC

3.2

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

Load

1

34.6
41.0

Connection diagram
CC10-xxxxSx-E
+Vin

5.08 5.08 5.08

(18.92)

Coplanarity: 0.1 or lower

38.86

Outer shape of
product

1.2

35.56

15.24

t=0.3

10.16

8.8max.

4.0

(3.68)

22.6±0.2

No.1
No.2
No.3
No.4
No.5
No.6
No.7

+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout

17

CC15-E
CC15-E Specifications
MODEL
CC15-2403Sx-E
CC15-2405Sx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
89
Current (typ)
(*1) A
0.695
0.702
VDC
3.3
5
Nominal Voltage
Maximum Current
A
4.500
3.000
Maximum Power
(*2) W
14.85
15
Maximum Line Regulation(Within input voltage range) mV
65
100
Maximum Load Regulation (0-100% load) mV
120
200
Output
Temperature Coefficient
80mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*3) %
+5/-3
Maximum Ripple & Noise (typ/max) (*4) mVp-p
40/120
Voltage Adjustable Range
Not available
Over Current Protection
(*5)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
12.5
Mechanical
Size (W x H x D)
mm
DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°
C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.

・All specifications are subject to change without notice.

18

CC15-E
Outline Drawing
CC15-xxxxxSF-E (DIP type)
Recommended measurements for mounting board

6.075

27.33

25.4

6.075

37.55

17-0.3×0.6
b

a

10.16
2-ø1.5 (land diameter ø2.5)

1.0
b

6.075
31.475
P=2.54

37.55

2.7

17

a

0.5

11
12
13
14
15
16

25-ø1.0 (land diameter ø2.0)

3.5

b

Outer shape of product

0.5

a

2.54

10
9
8
7
6
5
4
3
2
1

2.7

22.86

t=0.3

10.16

3.0
(4.62)
2.54
(4.62)

P P P P P P P P 4.47

32.1

7.0max.

38.1

P P P P P

Shape/Dimensions

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

CC15-xxxxxSR-E (SMD type)
Recommended measurements for mounting board

27.33

2.54

11
12
13
14
15
16

10.16

(4.62)
2.54
(4.62)

10
9
8
7
6
5
4
3
2
1

17-0.3×0.6

10.16

Coplanarity: 0.1 or lower

22.86

t=0.3
40.9

Outer shape of product

3.2

17

1.8

+Vin

–Vout
Load

–Vin

Terminal connections

17

16
15
14
13
12
11

+Vout

No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9

NC
NC
RC
NC
NC
+Vin
+Vin
–Vin
–Vin

No.10
No.11
No.12
No.13
No.14
No.15
No.16
No.17

NC
NC
+Vout
+Vout
+Vout
–Vout
–Vout
NC

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)

・All specifications are subject to change without notice.

3.2
P=2.54

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

Connection diagram
1
2
3
4
5
6
7
8
9
10

36.6
43.0

1.8

RC

P P P P P

7.5max.

32.1

1.2

38.1

P P P P P P P P P 4.47

Shape/Dimensions

19

CC25-E
CC25-E Specifications
MODEL
CC25-2403Sx-E
CC25-2405Sx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1) %
90
Current (typ)
(*1) A
1.146
1.157
VDC
3.3
5
Nominal Voltage
Maximum Current
A
7.500
5.000
Maximum Power
(*2) W
24.75
25
Maximum Line Regulation (Within input voltage range) mV
65
100
Maximum Load Regulation (0-100% load) mV
120
200
Output
Temperature Coefficient
80mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*3) %
+5/-3
Maximum Ripple & Noise (typ/max) (*4) mVp-p
40/120
Voltage Adjustable Range
VDC
Not available
Over Current Protection
(*5)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Between input terminal and output terminal: 500VDC, 50MΩ min
Isolation Resistance
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Weight (typ)
g
20
Mechanical
Size (W x H x D)
mm
DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°
C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40°
C and +50°
C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°
C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.

・All specifications are subject to change without notice.

20

CC25-E
Outline Drawing
CC25-xxxxSF-E (DIP type)
Shape/Dimensions

Recommended measurements for mounting board

43.2

30.5

5.08
PPPPP

6.075

6.075

6
5
4
3
2
1

35.56

PPP
6.075

36.575
42.65

P=2.54

25

b

a

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

Recommended measurements for mounting board

43.2

7.5max.

4.52

44.9

Outer shape of product

35.56

40.08

(4.67)

48.1

25

Terminal connections
–Vout

No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9

Load

25
24
23
22
21
20
19
18
17
16
15
14

3.2

P=2.54

Unit: mm
Allowable tolerance is ±0.5 if not specified separately.

Connection diagram
1
2
RC
3
4
5
–Vin 6
7
8
9
10
11
12
+Vin 13

41.7

3.2

(4.67)

6
5
4
3
2
1

PPP

9
8
7

14
15
16
17
18
19
20
21
22
23
24

10.16

13
12
11
10

P P P P P P P P P P 10.16

Coplanarity: 0.1 or lower
1.8

5.08
PP

46.0

5.08
PPPPP

t=0.3

1.8

5.08

2-ø1.5 (land diameter ø2.5)

2.7

Shape/Dimensions

5.08

5.08
PP

1.0
a

CC25-xxxxSR-E (SMD type)

2.54

25-ø1.0 (land diameter ø2.0)

10.16

9
8
7 25-0.3×0.6

2.7

b

3.5

14
15
16
17
18
19
20
21
22
23
24

0.5

b

0.5

a

(4.67)

13
12
11
10

40.08

42.65

P P P P P P P P P P 10.16

Outer shape of product
t=0.3

(4.67)

2.54

5.08

5.08

3.0

7.0max.

4.52

44.9

+Vout

NC
NC
NC
RC
NC
NC
–Vin
–Vin
–Vin

No.10
No.11
No.12
No.13
No.14
No.15
No.16
No.17
No.18

+Vin
+Vin
+Vin
NC
NC
+Vout
+Vout
+Vout
+Vout

No.19
No.20
No.21
No.22
No.23
No.24
No.25

Derating Curve
Output power (%)

100
Natural air cooling

80

a

b

60
40
20

a:0.5m/s(100LFM)
b:1m/s(200LFM)

0
-40 -20

0

20

40

60

80 100

Ambient temperature (°
C)

Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.

–Vout
–Vout
–Vout
–Vout
–Vout
–Vout
NC

21

CC-E
CC-E Instruction Manual
1. Control functions/Protection functions/Connections
1. Remote On/Off terminal (RC)
1.5-10W type
Open collector is recommended as the connection system.
Consult us for use with other systems.
Use a transistor with "VCE: Vin or over" and "Ic: 1mA or
over".
Output is switched off by setting the RC terminal open, and
switched on by setting the RC terminal to LOW (0-0.4V).
+Vout

DIP/SMDmodels

Load

RC
–Vout

When not using this function (always on), short-circuit between RC terminal and -Vin terminal.
+Vout
Load

+Vin

Load

+Vin

–Vin

–Vout

–12V

+15V

+Vout

Load

TRM
COM
–Vin

Load

–Vout

–15V

SIPmodels
Model name
CC3–xx03SS–E
CC3–xx05SS–E
CC3–xx12SS–E
CC3–xx12DS–E

Model name
3.3V
5V
12V
±12V

Connection to -Vout
3.67V
6V
15V
±15V

Fig.
3
3
3
4

Load

Load

3.3V, 5V, 12V

+Vin

–Vin

TRM

–Vout

+Vout

+Vin

–Vin

Fig.3

3.67V, 6V, 15V

Load

Load

Load
–12V

+15V

Load
–15V

+Vin

–Vin

TRM

–Vout

COM

+Vout

+Vin

COM

+Vout

Fig.4

+12V

・All specifications are subject to change without notice.

Load

–Vout

–Vout

Load
–Vout

+Vin

Load

TRM
COM

–Vout

+Vout

+12V

+Vout

+Vout

Load
–Vout

RC
–Vin

TRM

–Vout

–Vin

+Vout

RC

+Vin

3.6V
6V
15V

+Vout

Fig.2

When not using this function (always on), set the RC terminal to open.
When not
using this
function
(always on)

+Vin

Load

TRM

Output is switched on by setting the RC terminal to open,
and switched off by setting the RC terminal to HIGH (connecting to Vin terminal).

–Vin

3.3V
5V
12V

+Vout

–Vout

15/25W type

RC
control
signal

Fig.
1
1
1
2

To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.

–Vin

+Vin

Connection to -Vout
3.6V
6V
15V
±15V

Fig.1

RC
–Vin

Open
3.3V
5V
12V
±12V

–Vin

+Vin
When not
using this
function
(always on)

Model name
CC –xx03Sx–E
CC –xx05Sx–E
CC –xx12Sx–E
CC –xx12Dx–E

TRM

–Vin

Output voltage can be set to the values shown in the figure
below by connecting the TRM terminal to the -Vout terminal.
When not using this function (always on), set the TRM terminal to open.
Note that when the output voltage is set high by this function, derating of output current is necessary according to
the maximum power.

TRM

+Vin
RC
control
signal

1-2. Output voltage adjusting terminal (TRM) (1.5-10W type)

22

CC-E
For the ±12V output model,
24V single output by making the COM terminal and TRM

Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low

terminal open. And output voltage can be set to 30V single

*5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb ≧ 62]

output by making the COM terminal open and connecting

*6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb ≧ 160]

the TRM terminal to the -Vout terminal.

*7 Vout = 12.01 - 431.1/(57+Rb) [Rb ≧ 620]
*8 Vout = 12.02 - 968.5/(103+Rb) [Rb ≧ 1500]

models
Model name

COM terminal TRM terminal
Single output Fig.
Open
Open
Open
Connection to -Vout

* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Fig.5

Fig.6

+Vin

+Vout

24V

+Vout

30V

TRM

Load

COM
–Vin

+Vin

Load

TRM

COM
–Vin

–Vout

–Vout

Adding a resistance Rb between TRM terminal and +Vout
terminal, to set the output voltage low
*5 Rb = 15.53/(3.3-Vout) - 39.6
*6 Rb = 52.55/(5.01-Vout) - 31.8
*7 Rb = 431.1/(12.01-Vout) - 57
*8 Rb = 968.5/(12.02-Vout) - 103

models
Model name

COM terminal TRM terminal
Single output Fig.
Open
Open
Open
Connection to -Vout

+Vin

–Vin

TRM

–Vout

COM

+Vout

+Vin

–Vin

TRM

–Vout

Fig.8
COM

+Vout

Fig.7

Calculating connected resistance Ra, Rb (kΩ) from set output voltage Vout (V)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Ra = 9.59/(Vout-3.3) - 32
*2 Ra = 17.64/(Vout-5.01) - 17.8
*3 Ra = 50.53/(Vout-12.01) - 16.9
*4 Ra = 53.55/(Vout-12.02) - 18

Fig.9

Fig.10
3.3∼3.6V
5∼6V
12∼15V

+Vout

30V

TRM
Ra

1-3. Output voltage adjusting function (adding external resistance)
(1.5-10W type)
Output voltage can be varied in the range shown in the figure below by connecting a resistance (Ra, Rb) between the
TRM terminal and the -Vout terminal or between the TRM
terminal and +Vout terminal.
Note that when the output voltage is set high, derating
of output current is necessary according to the maximum
power.
models
Model name

Connection between
Fig.
-Vout and Ra
to
to
to
to

Connection between
Fig.
+Vout and Rb
to
to
to
to

* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.

Calculating output voltage Vout (V) from connected resistance Ra, Rb (kΩ)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 9.59/(32+Ra)
*2 Vout = 5.01 + 17.64/(17.8+Ra)
*3 Vout = 12.01 + 50.53/(16.9+Ra)
*4 Vout = 12.02 + 53.55/(18+Ra)

・All specifications are subject to change without notice.

Rb
TRM

–Vout

3.15∼3.3V
4.75∼5V
11.4∼12V

Load

Load

24V

Load

Load

*5, *6, *7

+Vout

–Vout
*1, *2, *3

Fig.11

Fig.12
+12∼+15V

+Vout

Load

TRM
COM
–Vout

*8

+Vout
TRM

Rb

+11.4∼+12V
Load

COM
Ra
*4

Load
–12∼–15V

Load
–Vout

–11.4∼–12V

models
Connection between
Connection between
Fig.
Fig.
-Vout and Ra
+Vout and Rb
to
to
to
to
to
to
to
to
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Model name

Calculating output voltage Vout (V) from connected resistance Ra, Rb (kΩ)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 1.04/(2.83+Ra)
*2 Vout = 5 + 12.75/(12.69+Ra)
*3 Vout = 12 + 48.4/(16.18+Ra)
*4 Vout = 12 + 54.7/(18+Ra)
Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb ≧ 7.6]
*6 Vout = 5 - 12.78/(17.79+Rb) [Rb ≧ 33.3]
*7 Vout = 12 - 184.1/(35.54+Rb) [Rb ≧ 271.3]
*8 Vout = 12 -470.3/(61.75+Rb) [Rb ≧ 722.1]

23

CC-E
Calculating connected resistance Ra, Rb (kΩ) from set output voltage Vout (V)

1-5. Over voltage protection

Adding a resistance Ra between TRM terminal and -Vout

An over voltage protection function is not incorporated in

terminal, to set the output voltage high

the model. Be careful if an external voltage over the nomi-

*1 Ra = 1.04/(Vout-3.3) - 2.83

nal voltage is applied, damage may be caused.

*2 Ra = 12.75/(Vout-5) - 12.69
*3 Ra = 48.4/(Vout-12) - 16.18
*4 Ra = 54.7/(Vout-12) - 18

1-6. Low input voltage protection

Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Rb = 1.69/(3.3-Vout) - 3.66
*6 Rb = 12.78/(5-Vout) - 17.79
*7 Rb = 184.1/(12-Vout) - 35.54
*8 Rb = 470.3/(12-Vout) - 61.75

*5, *6, *7

Load
3.15∼3.3V、4.75∼5V、11.4∼12V

Ra *4
Load Load
+12∼+15V
–12∼–15V

TRM

–Vout

COM

+Vout

TRM

–Vout

Fig.16
COM

+Vout

TRM
Rb

Ra *1, *2, *3
Load
3.3∼3.67V、5∼6V、12∼15V

Fig.15

–Vout

TRM

–Vout

+Vout

Fig.14

+Vout

Fig.13

Rb
Load

Load

+11.4∼+12V

*8

–11.4∼–12V

1-4. Over current protection
1.5-10W type
An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered. By removing the over current and shorted conditions, the output voltage automatically resumes. Note that
if the over current status continues for 30 seconds or over,
the internal elements of the converter may be deteriorated
or damaged. The current value, from which it is judged as
an over current, is not to be lower than the nominal current
value. Due to fold back characteristics of OCP, the output
may not rise up steady with constant current load or inductive load.

This series is equipped with the low input voltage protection in order to prevent malfunction due to low input voltage. The converter stops operation if the input voltage
become lower than the set voltage. The set ranges are
shown in the table below.
Model name

Input voltage range
Voltage range set for protection circuit
to
to
to
to
to
to
to
to
to
to
to
to
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.

The above setting value is fixed and cannot be adjusted
externally.

1-7. Insulation withstand voltage
The insulation withstand voltage between input and output,
and between terminal and case, is AC500V.

1-8. Series/Parallel connections
Series connection
Serial connection is applicable by wiring as shown in the
figure below (left). If output voltage is not generated by this
connection, connect a Schottky barrier diode in which the
forward voltage is possibly low.
Also note that the Schottky barrier diode should have a
reverse voltage that is twice or over the value of the voltage
between +Vout and -Vout.
And the output current should be the same or lower than the
nominal current value, whichever is smaller in the converters.
+Vin

+Vout

15/25W type

–Vin

–Vout

–Vin

–Vout

An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered and the converter is stopped and latched. The
output voltage does not automatically resume even after
removing the over current and shorted conditions.
To resume output voltage, restart input or reset remote on/
off.
The current value, from which it is judged as an over current, is not to be lower than the nominal current value.

+Vin

+Vout

+Vin

+Vout

–Vin

–Vout

–Vin

–Vout

・All specifications are subject to change without notice.

Parallel connection
Parallel connection is not applicable.

Load

+Vout

Load

+Vin

24

CC-E
2. Noise reduction methods
2-1. Output ripple noise measurement method

2-3. Output ripple & noise

The measured value of the converter noise may differ de-

To reduce Output ripple & noise, connect a capacitor to

pending on the measurement method. Measurement should
be conducted in a position close to the output terminal.
When connecting a prove, do not allow a loop to be configured in order not to pick up flux.
As well, note that the spike voltage greatly differs depending on the ripple voltmeter and frequency band of the oscilloscope.
Our noise measurement is conducted by the wiring shown

the output of the converter. In addition, reduction can be
enhanced if a π type filter is incorporated as shown in the
figure below. In this case, use of a coil with around 100µH
is recommended.

Iin

A
lout

V

V

Vout

Load

Vin

0.1µF

–Vout
50Ω coaxial cable
1.5m

–Vin

A

–Vout

+Vout

–Vin

–Vout

20mm

+Vout

+Vin

–Vin

+Vin

Load

10mm

+Vout
Load

in the figure below and in the frequency band of 50MHz.

+Vin

Ripple
voltmeter
50MHz

+Vin

+Vout
1 F

2-2. Input ripple noise

–Vin

Load

Oscilloscope
or
50MHz
End-point: 50Ω+0.1µF

When the distance to the load from the output of the converter is long, connect the capacitor as close as possible
to the load.
To reduce output spike noise, connect a ceramic capacitor
with around 1µF to the output of the converter.

–Vout

This series is equipped with a built-in capacitor for input.
However, by connecting a capacitor with around 10 µF,
input ripple noise and input return noise can be reduced.

–Vin

–Vout

+Vin

+Vout

–Vin

–Vout

Load

+Vout
Load

+Vin

When the distance to the input of the converter from the
input power supply is long, attach a capacitor as close as
possible to the input terminal.
+Vout

–Vin

–Vout

Load

+Vin

When the distance to the input of the converter from the
input power supply is long, the impedance of the input line
can become high, causing high spike noise.
In this case, it is recommended to connect a capacitor as
close as possible to the input of the DC-DC converter.

・All specifications are subject to change without notice.

2-4. Capacity of external capacitor connected to output
Note that if a capacitor with capacity over the value shown
in the table below is connected to the output, or several
capacitors with low impedance are connected in parallel,
operation of the converter may become unstable.
Model name

Electrostatic capacitance (µF) max.

25

CC-E
2-5. Common mode noise

2-6. Radiation noise

For products other than with 10W, capacitors are not con-

Radiation noise of the converter can be reduced by con-

nected between the primary GND and the secondary GND.

necting the case terminal to the input or output GND ter-

To reduce common mode noise, connect a capacitor with

minal. The effectiveness varies depending on the device.

around 1000pF between the primary GND and the secondary GND, as shown in the figure below.
In this case, note that if the capacitor that is connected is
too large, coupling capacitance between input and output
becomes large.
Also be careful about the withstand voltage of the capacitor
(500V or over is desirable with consideration of the insula-

Check it on the actual device.
Regarding wiring, use GND line and solid pattern for the
bottom of the converter as much as possible.
- SMD models are not equipped with case terminals.

tion withstand voltage).
+Vout

–Vin

–Vout

Load

+Vin

For products with 10W, capacitors with 1000pF are internally connected between primary and secondary.

3. Soldering conditions/Cleaning conditions
3-1. Soldering conditions
●Soldering conditions
DIP models / SIP models
Observe the following conditions in soldering board.
Solder dip
Soldering copper

260°C, 10s max., 1 time
380°C, 3s max., 1 time/PIN

SMD models
Lead-free soldering / High-temperature reflow process
Surface temperature of parts

30 20s

245˚C max.
225˚C min.

3-2. Cleaning method
Board cleaning after soldering is not recommended. However, the cleaning fluids and conditions shown in the table
below have been tested and proved to have no problem.
These fluids and conditions can be used.
Cleaning fluids and test conditions
Cleanthrough 750H
(1) Cleaning (shaking) at 60°
C for 4 minutes
(2) Rinsing (shaking in water) at 60°
C for 4 minutes
(3) Rinsing (shaking in water) at ordinary temperature 40°
C for 4 minutes
(4) Drying at 70°
C for 6 minutes

180˚C
150˚C

1 to 3˚C/s

40 to 100s

1 to 4˚C/s 1 to 5˚C/s

The reflow must be 1 time only.
(Do not reflow with the on-board module on the motherboard underside.)

Pine alpha ST100S
(1) Cleaning (shaking) at 60°
C for 5 minutes
(2) Rinsing (shaking in water) at 30°
C for 3 minutes
(3) Drying at 70°
C for 6 minutes
Terpene Cleaner EC-7R
(1) Cleaning (shaking) at 60°
C for 5 minutes
(2) Rinsing (shaking in IPA) at 30°
C for 10 minutes
(3) Drying at 70°
C for 6 minutes
Isopropyl alcohol
(1) Ultrasonic waves at 60°
C for 1 minute
(2) Cool bath cleaning R.T. for 1 minute
(3) Vapor cleaning at 83°
C for 1 minutes
Asahiklin AK-225AES
(1) Ultrasonic waves at 50°
C for 2 minutes
(2) Cool bath cleaning R.T. for 2 minutes

・All specifications are subject to change without notice.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Create Date                     : 2017:10:12 04:43:42+09:00
Creator                         : Adobe InDesign CS4_J (6.0.6)
Modify Date                     : 2017:10:20 14:58:58+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Instance ID                     : uuid:5bb4e664-ef4b-4dde-bddd-a9572b39e230
Document ID                     : xmp.did:6D8DFE34DD24E511A461B653B8D2EF37
Original Document ID            : adobe:docid:indd:fe86c10a-63c4-11e1-8eda-9c6383d50538
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6C8DFE34DD24E511A461B653B8D2EF37
Derived From Document ID        : xmp.did:CDBD566BB7FCE311AE59AB72ABC97353
Derived From Original Document ID: adobe:docid:indd:fe86c10a-63c4-11e1-8eda-9c6383d50538
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:7ABEC9E15211E211BCBF91DA050B1312, xmp.iid:7BBEC9E15211E211BCBF91DA050B1312, xmp.iid:7CBEC9E15211E211BCBF91DA050B1312, xmp.iid:7DBEC9E15211E211BCBF91DA050B1312, xmp.iid:7EBEC9E15211E211BCBF91DA050B1312, xmp.iid:7FBEC9E15211E211BCBF91DA050B1312, xmp.iid:80BEC9E15211E211BCBF91DA050B1312, xmp.iid:81BEC9E15211E211BCBF91DA050B1312, xmp.iid:82BEC9E15211E211BCBF91DA050B1312, xmp.iid:83BEC9E15211E211BCBF91DA050B1312, xmp.iid:AB042DFC8C11E211BCBF91DA050B1312, xmp.iid:77F4301B9D12E211A837B6D8362C01C2, xmp.iid:1ABDFD7D5019E211929B9838D0BC3A3E, xmp.iid:7373434AB519E211A8C3B7B080372E90, xmp.iid:2C64D02FD81CE2119181C5575BF14E22, xmp.iid:2D64D02FD81CE2119181C5575BF14E22, xmp.iid:2E64D02FD81CE2119181C5575BF14E22, xmp.iid:CCBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CDBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CEBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CFBD566BB7FCE311AE59AB72ABC97353, xmp.iid:D0BD566BB7FCE311AE59AB72ABC97353, xmp.iid:D1BD566BB7FCE311AE59AB72ABC97353, xmp.iid:071A9C5FBE1DE511AC16AEC844A5D0C2, xmp.iid:081A9C5FBE1DE511AC16AEC844A5D0C2, xmp.iid:6C8DFE34DD24E511A461B653B8D2EF37, xmp.iid:6D8DFE34DD24E511A461B653B8D2EF37, xmp.iid:BBDE857C1447E71183AAB600697B5B8B, xmp.iid:BCDE857C1447E71183AAB600697B5B8B, xmp.iid:BDDE857C1447E71183AAB600697B5B8B, xmp.iid:198AAEB15649E711AB48E6E96362EE39, xmp.iid:1A8AAEB15649E711AB48E6E96362EE39, xmp.iid:E2AB68FCE44AE71181DBCA9E9CD1EC74, xmp.iid:E3AB68FCE44AE71181DBCA9E9CD1EC74, xmp.iid:E7DC99DD4CA8E711844FD3150BCA53D0, xmp.iid:F0ED4F293CA9E711B528A11A366557D8, xmp.iid:F1ED4F293CA9E711B528A11A366557D8, xmp.iid:01ED2473BCAEE7118407B5DA40B92427
History When                    : 2012:10:08 23:17:24+09:00, 2012:10:08 23:17:24+09:00, 2012:10:09 03:14:29+09:00, 2012:10:09 05:03:44+09:00, 2012:10:09 05:22:35+09:00, 2012:10:09 05:54:51+09:00, 2012:10:09 06:02:26+09:00, 2012:10:09 06:03:25+09:00, 2012:10:09 06:09:09+09:00, 2012:10:09 06:10:37+09:00, 2012:10:09 06:13:19+09:00, 2012:10:10 14:41:14+09:00, 2012:10:19 03:20:27+09:00, 2012:10:19 15:21:59+09:00, 2012:10:23 15:09:21+09:00, 2012:10:23 15:09:21+09:00, 2012:10:23 15:09:50+09:00, 2014:06:26 07:24:06+09:00, 2014:06:26 07:24:06+09:00, 2014:06:26 07:45:19+09:00, 2014:06:26 08:29:41+09:00, 2014:06:26 08:36:51+09:00, 2014:06:26 08:37:22+09:00, 2015:06:29 02:51:58+09:00, 2015:06:29 02:57:15+09:00, 2015:07:08 04:56:36+09:00, 2015:07:08 04:56:36+09:00, 2017:06:02 06:51:37+09:00, 2017:06:02 07:50:26+09:00, 2017:06:02 07:51:56+09:00, 2017:06:05 05:16:37+09:00, 2017:06:05 05:31:34+09:00, 2017:06:07 04:29:02+09:00, 2017:06:07 05:29:01+09:00, 2017:10:04 05:26:32+09:00, 2017:10:05 04:42:31+09:00, 2017:10:05 05:55:04+09:00, 2017:10:12 04:43:26+09:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /, /, /, /, /, /, /, /, /, /, /, /metadata, /, /, /metadata, /;/metadata, /, /, /, /, /, /, /metadata, /, /, /, /, /, /, /, /, /, /, /, /
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:f57c3eb0-1092-401d-a064-28eba9c7a769, uuid:8739bf62-05bf-41fb-9e47-10c12a321b12, uuid:28b981aa-dcf8-4e2e-9142-89b48c529876, uuid:9596c852-eae6-411e-a839-ddad8e439b86, uuid:607043c8-5b7d-4b56-8054-9a42fbc7e965, uuid:3e81ccbd-c3e5-4bf0-983a-43c418a80806, uuid:0a5cac5e-dfed-4930-b9f6-4c90930ed230, uuid:0d4a51c9-482d-4ca7-8022-f6e6bd50b880, uuid:1b86b07a-9bfe-4758-8186-ff9200c97b0f, uuid:f8a32fa0-ef1b-445c-b69e-5f786c381c0a, uuid:fdba2883-e66c-4eeb-95ae-2a0d9f048343, uuid:05ad283c-e243-4ff2-87bd-5dc0ef39964f, uuid:3269698f-a049-48a0-a5f1-cecbe8b5f4d2, uuid:f59a128d-c7a6-4986-b802-d9f60106ff76, uuid:28366666-e139-410e-a86c-7e7916614676, uuid:dcbf596b-58db-42e4-9511-b901704a0018, uuid:0813824c-3383-455b-b091-e9a44e5af66f, uuid:0476f86c-8f4d-4f81-9178-b6d324ae1658, uuid:75d489c0-ce00-4e48-b733-620e8e78f2f6, uuid:8abc58e7-5ab4-4d6c-9b71-bca062c24c99, uuid:0a504583-6d1a-4eac-9665-fce81ac9dbb8, uuid:0ef003a8-9012-4b37-886b-93e3eaa92b52, uuid:89688754-6032-42bb-b392-385bf1d300ef, uuid:ee637aa6-ed10-44c7-a91f-7fbc8d61fb12, uuid:f2fd14fe-0f87-4de6-8bc4-ee1b692f238a
Manifest Reference Document ID  : xmp.did:CE4D6991B8FBE311AB55BD2B47BE6733, xmp.did:8A9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8B9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8C9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8D9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8E9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8F9CBF9C31FAE3119632F11A9D872FC4, xmp.did:909CBF9C31FAE3119632F11A9D872FC4, xmp.did:919CBF9C31FAE3119632F11A9D872FC4, xmp.did:4E4670256DFBE311B2C7FE1C05E13361, xmp.did:4F4670256DFBE311B2C7FE1C05E13361, xmp.did:504670256DFBE311B2C7FE1C05E13361, xmp.did:524670256DFBE311B2C7FE1C05E13361, xmp.did:534670256DFBE311B2C7FE1C05E13361, xmp.did:544670256DFBE311B2C7FE1C05E13361, xmp.did:554670256DFBE311B2C7FE1C05E13361, xmp.did:564670256DFBE311B2C7FE1C05E13361, xmp.did:574670256DFBE311B2C7FE1C05E13361, xmp.did:0C1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0D1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0E1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0F1D46B06FFBE311B2C7FE1C05E13361, xmp.did:101D46B06FFBE311B2C7FE1C05E13361, xmp.did:111D46B06FFBE311B2C7FE1C05E13361, xmp.did:121D46B06FFBE311B2C7FE1C05E13361
Metadata Date                   : 2017:10:20 14:58:58+09:00
Creator Tool                    : Adobe InDesign CS4_J (6.0.6)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 14029 bytes, use -b option to extract)
Doc Change Count                : 587
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 25
EXIF Metadata provided by EXIF.tools

Navigation menu