CC3 Cc E
User Manual: CC3
Open the PDF directly: View PDF .
Page Count: 25
Download | |
Open PDF In Browser | View PDF |
1 CC-E Insulation type DC-DC converter Low Voltage Directive ■ Features R: Horizontally-mounted SMD type FS Vertically-mounted SIP type Symbol for number of outputs S: Single output, D: Dual outputs Nominal output voltage 03: 3.3V, 05: 5V, 12: 12V Nominal input voltage 05: 5V, 12: 12V, 24: 24V, 48: 48V ●5-side metal-shielded low noise design ●Lightweight design with no resin filled up ●Supports DIP insertion,SMD mounting and SIP vertical insertion (3W products) ●Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL), and EN60950-1 (NEMKO) Maximum output power 1R5: 1.5W, 3: 3W, 6:6W 10: 10W, 15: 15W, 25: 25W Representing series name by combination with "-E"at the end ■ Conformity to RoHS Directive ■ Applications This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retar dants, PBB and PBDE, have not been used, except for exempted applications. ■ Product Line up 1.5W DIP type SMD type Model name (output voltage: 5V) SIP type Output current DIP type SMD type Model name (output voltage: 12V/15V) SIP type Output current DIP type SMD type Model name (output voltage: ±12V/±15V) SIP type Output current DIP type SMD type SIP type 0.4A CC1R5-0503SF-E CC1R5-0503SR-E - 0.3A CC1R5-0505SF-E CC1R5-0505SR-E - 0.125A (0.1A) CC1R5-0512SF-E CC1R5-0512SR-E - 0.06A (0.05A) CC1R5-0512DF-E CC1R5-0512DR-E - 12V 0.4A CC1R5-1203SF-E CC1R5-1203SR-E - 0.3A CC1R5-1205SF-E CC1R5-1205SR-E - 0.125A (0.1A) CC1R5-1212SF-E CC1R5-1212SR-E - 0.06A (0.05A) CC1R5-1212DF-E CC1R5-1212DR-E - 24V 0.4A CC1R5-2403SF-E CC1R5-2403SR-E - 0.3A CC1R5-2405SF-E CC1R5-2405SR-E - 0.125A (0.1A) CC1R5-2412SF-E CC1R5-2412SR-E - 0.06A (0.05A) CC1R5-2412DF-E CC1R5-2412DR-E - 48V 0.4A CC1R5-4803SF-E CC1R5-4803SR-E - 0.3A CC1R5-4805SF-E CC1R5-4805SR-E - 0.125A (0.1A) CC1R5-4812SF-E CC1R5-4812SR-E - 0.06A (0.05A) CC1R5-4812DF-E CC1R5-4812DR-E - 0.8A CC3-0503SF-E CC3-0503SR-E CC3-0503SS-E 0.6A CC3-0505SF-E CC3-0505SR-E CC3-0505SS-E 0.25A (0.2A) CC3-0512SF-E CC3-0512SR-E CC3-0512SS-E 0.125A (0.1A) CC3-0512DF-E CC3-0512DR-E CC3-0512DS-E 12V 0.8A CC3-1203SF-E CC3-1203SR-E CC3-1203SS-E 0.6A 5V 3W Model name (output voltage: 3.3V) Output current warranty Shape F: Horizontally-mounted DIP type High accuracy of ± 3% in output voltage (10W of lower single output) 5V 5 ■ Model-naming method CC 3 - 05 05 S F -E ●Mounting area halved compared to existing products ●Nonuse of tantalum capacitor or aluminum electrolytic capacitor ●Remote On/Off function incorporated in all series of products Output Input power voltage EN60950-1 UL60950-1/ CSA C22.2 No.60950-1 Y E A R S CC3-1205SF-E CC3-1205SR-E CC3-1205SS-E 0.25A (0.2A) CC3-1212SF-E CC3-1212SR-E CC3-1212SS-E 0.125A (0.1A) CC3-1212DF-E CC3-1212DR-E CC3-1212DS-E 0.6A CC3-2405SF-E CC3-2405SR-E CC3-2405SS-E 0.25A (0.2A) CC3-2412SF-E CC3-2412DR-E CC3-2412DS-E 48V 0.8A CC3-4803SF-E CC3-4803SR-E CC3-4803SS-E 0.6A CC3-4805SF-E CC3-4805SR-E CC3-4805SS-E 0.25A (0.2A) CC3-4812SF-E CC3-2412SR-E CC3-2412SS-E 0.125A (0.1A) CC3-2412DF-E CC3-4812SR-E 0.125A (0.1A) CC3-4812DF-E 5V 24V 0.8A CC3-2403SF-E CC3-2403SR-E - CC3-4812DR-E CC3-4812DS-E 1.2A CC6-0503SF-E CC6-0503SR-E - 1A CC6-0505SF-E CC6-0505SR-E - 0.5A (0.4A) CC6-0512SF-E CC6-0512SR-E - 0.25A (0.2A) CC6-0512DF-E CC6-0512DR-E - 12V 1.2A CC6-1203SF-E CC6-1203SR-E - 1.2A CC6-1205SF-E CC6-1205SR-E - 0.5A (0.4A) CC6-1212SF-E CC6-1212SR-E - 0.25A (0.2A) CC6-1212DF-E CC6-1212DR-E - 24V 1.2A CC6-2403SF-E CC6-2403SR-E - 1.2A CC6-2405SF-E CC6-2405SR-E - 0.5A (0.4A) CC6-2412SF-E CC6-2412SR-E - 0.25A (0.2A) CC6-2412DF-E CC6-2412DR-E - 48V 1.2A CC6-4803SF-E CC6-4803SR-E - 1.2A CC6-4805SF-E CC6-4805SR-E - 0.5A (0.4A) CC6-4812SF-E CC6-4812SR-E - 0.25A (0.2A) CC6-4812DF-E CC6-4812DR-E - 2.5A CC10-0503SF-E CC10-0503SR-E - 2A CC10-0505SF-E CC10-0505SR-E - 0.8A (0.64A) CC10-0512SF-E CC10-0512SR-E - 0.4A (0.32A) CC10-0512DF-E CC10-0512DR-E - 12V 2.5A CC10-1203SF-E CC10-1203SR-E - 2A CC10-1205SF-E CC10-1205SR-E - 1A (0.8A) CC10-1212SF-E CC10-1212SR-E - 0.45A (0.36A) CC10-1212DF-E CC10-1212DR-E - 24V 2.5A CC10-2403SF-E CC10-2403SR-E - 2A CC10-2405SF-E CC10-2405SR-E - 1A (0.8A) CC10-2412SF-E CC10-2412SR-E - 0.45A (0.36A) CC10-2412DF-E CC10-2412DR-E - 48V 2.5A CC10-4803SF-E CC10-4803SR-E - 2A CC10-4805SF-E CC10-4805SR-E - 1A (0.8A) CC10-4812SF-E CC10-4812SR-E - 0.45A (0.36A) CC10-4812DF-E CC10-4812DR-E 15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E - 3A CC15-2405SF-E CC15-2405SR-E - - - - - - - - - 25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E - 5A CC25-2405SF-E CC25-2405SR-E - - - - - - - - - 6W 5V 10W - web171023 ・All specifications are subject to change without notice. 2 CC1R5-E CC1R5-E Specifications MODEL CC1R5-0503Sx-E CC1R5-0505Sx-E CC1R5-0512Sx-E CC1R5-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) % 71 77 80 79 Current (typ) (*1) A 0.372 0.390 0.375 0.380 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature–40° C to +50° C) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC1R5-1203Sx-E CC1R5-1205Sx-E CC1R5-1212Sx-E CC1R5-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature–40° C to +50° C) Max Power Total Regulation (max) (*4) % 3 ±5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. CC1R5-E MODEL CC1R5-2403Sx-E CC1R5-2405Sx-E CC1R5-2412Sx-E CC1R5-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 72 77 81 79 Current (typ) (*1) A 0.076 0.081 0.077 0.079 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature–40° C to +50° C) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC1R5-4803Sx-E CC1R5-4805Sx-E CC1R5-4812Sx-E CC1R5-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) % 70 76 80 79 Current (typ) (*1) A 0.039 0.041 0.039 0.040 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature–40° C to +50° C) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Between input terminal and output terminal: 500VDC, 50MΩ min Isolation Resistance Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. 3 4 CC1R5-E Outline Drawing CC1R5-xxxxxF-E (DIP type) 16.6±0.2 Recommended measurements for mounting board 13.08 12.7 16.51 5 7-0.3×0.6 2-ø1.5 (land diameter ø2.5) 6 7 a 1 b 3.5 2 7-ø1.0 (land diameter ø2.0) 16.51 1.0 0.5 b 4 2.7 a Outer shape of product 0.5 1.905 2.54 5.08 2.54 (3.22) 12.7 a 3 7.62 2.54 (3.22) 1.905 10.16 3.5 t=0.3 2.54 5.08 2.54 2.92 14.605 7.62 8.5max. 4.0 Shape/Dimensions b Unit: mm Allowable tolerance is ±0.5 if not specified separately. 2.7 CC1R5-xxxxxR-E (SMD type) 16.6±0.2 Recommended measurements for mounting board (3.22) 1.8 2.54 (3.22) 1.8 2.54 5.08 2.54 (13.38) Coplanarity: 0.1 or lower 19.81 Outer shape of product 1.2 16.51 10.16 t=0.3 7.62 8.8max. 4.0 Shape/Dimensions 3.2 2 5 7-0.3×0.6 6 (3.22) 1 7 1 7 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 3 No.1 No.2 No.3 No.4 No.5 No.6 No.7 TRM –Vout 4 NC +Vin +Vin RC –Vin NC –Vout TRM +Vout 7 1 6 RC 5 2 4 3 –Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. Terminal connections +Vout TRM COM –Vout Load –Vin 5 2 +Vout CC1R5-xxxxDx-E Load RC Terminal connections Load 6 3.2 22.0 Connection diagram CC1R5-xxxxSx-E +Vin 15.6 2.54 5.08 2.54 4 7.62 3 No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC –Vin –Vout Common out TRM +Vout CC3-E(DIP/SMD) 5 CC3-E Specifications MODEL CC3-0503Sx-E CC3-0505Sx-E CC3-0512Sx-E CC3-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) % 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Vibration Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-1203Sx-E CC3-1205Sx-E CC3-1212Sx-E CC3-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) % 74 79 82 81 Current (typ) (*1) A 0.297 0.316 0.305 0.309 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. CC3-E(DIP/SMD) MODEL CC3-2403Sx-E CC3-2405Sx-E CC3-2412Sx-E CC3-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-4803Sx-E CC3-4805Sx-E CC3-4812Sx-E CC3-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) % 73 79 81 80 Current (typ) (*1) A 0.075 0.079 0.077 0.078 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each Vibration Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 4.5 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. 6 CC3-E(DIP/SMD) 7 Outline Drawing CC3-xxxxxF-E (DIP type) 16.6±0.2 Recommended measurements for mounting board 2.92 20.32 22.86 2.54 a 2-ø1.5 (land diameter ø2.5) 2 5 6 7 1 b 22.86 1.0 0.5 4 7.62 3 3.5 b 7-0.3× 0.6 (3.22) 2.7 a 7-ø1.0 (land diameter ø2.0) 0.5 17.78 2.54 5.08 2.54 2.54 (3.22) 2.54 Outer shape of product 2.54 5.08 2.54 13.08 17.78 10.16 3.5 t=0.3 7.62 8.5max. 4.0 Shape/Dimensions b 2.7 Unit: mm Allowable tolerance is ±0.5 if not specified separately. a CC3-xxxxxR-E (SMD type) 16.6±0.2 (3.22) Recommended measurements for mounting board 7.62 2.54 5.08 2.54 Coplanarity: 0.1 or lower Outer shape of product 1.2 22.86 (13.38) t=0.3 10.16 8.8max. 4.0 Shape/Dimensions 26.16 1.8 1.8 3.2 22.0 3.2 4 2 5 7-0.3× 0.6 6 1 (3.22) 2.54 5.08 2.54 3 7.62 2.54 (3.22) 28.4 7 Connection diagram CC3-xxxxSx-E +Vin 7 –Vin 5 2 3 TRM –Vout 4 NC CC3-xxxxDx-E +Vin +Vin RC –Vin NC –Vout TRM +Vout 7 1 6 RC 5 2 4 3 –Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. Terminal connections +Vout TRM COM –Vout Load RC No.1 No.2 No.3 No.4 No.5 No.6 No.7 Load 6 Terminal connections +Vout Load 1 Unit: mm Allowable tolerance is ±0.5 if not specified separately. No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC –Vin –Vout Common out TRM +Vout CC3-E(SIP) 8 CC3-E Specifications MODEL CC3-0503SS-E CC3-0505SS-E CC3-0512SS-E CC3-0512DS-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) % 73 77 82 81 Current (typ) (*1) A 0.723 0.779 0.732 0.741 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-1205SS-E CC3-1212SS-E CC3-1212DS-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) % 79 82 Current (typ) (*1) A 0.316 0.305 VDC 5 12 15 12 15 Nominal Voltage Maximum Current A 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. CC3-E(SIP) MODEL CC3-2403SS-E CC3-2405SS-E CC3-2412SS-E CC3-2412DS-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC3-4803SS-E CC3-4805SS-E CC3-4812DS-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) % 73 79 82 Current (typ) (*1) A 0.075 0.079 0.076 VDC 3.3 5 12 15 Nominal Voltage Maximum Current A 0.800 0.600 0.125 0.100 Maximum Power (*2) W 2.64 3 Maximum Line Regulation (Within input voltage range) mV 20 80 Maximum Load Regulation (0-100% load) (*3) mV 40 600 Output Temperature Coefficient 80mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 7 Mechanical Size (W x H x D) mm 27.8 x 17.9 x 9.2 Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. 9 CC3-E(SIP) 10 Outline Drawing CC3-xxxxxS-E (SIP type) Shape/Dimensions 17.9 9.2 4 P P P P 2P P P P P 22.86 (0.5) 2.47 6 17.78 P=2.54 27.8 4 5 7 8 9 10 a 27.8 0.5 3 9.2 2 t=0.25 5.01 Recommended measurements for mounting board a 1 0.5 3.5 (0.5) 4.1 2.47 1(t=0.3) 2.47 4 22.86 2.47 17.78 2-ø1.5 (land diameter ø2.5) P Unit: mm Allowable tolerance is ±0.5 if not specified separately. P P P 2P P P P 6.0 Internal parts mounting space 9.2 P=2.54 9-ø0.8 (land diameter ø2.0) Connection diagram CC3-xxxxSS-E Load –Vin +Vin +Vin 10 RC 9 TRM 8 –Vout +Vin 7 Terminal connections COM +Vin 5 +Vout NC NC –Vout TRM NC RC –Vin +Vin +Vin COM –Vin 4 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 +Vout RC 3 TRM 2 –Vout Terminal connections +Vout 1 CC3-xxxxDS-E 1 2 3 4 5 7 8 9 10 Load Load Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 +Vout COM COM –Vout TRM NC RC –Vin +Vin +Vin 11 CC6-E CC6-E Specifications MODEL CC6-0503Sx-E CC6-0505Sx-E CC6-0512Sx-E CC6-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) % 76 79 82 Current (typ) (*1) A 1.042 1.266 1.463 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 1.200 1.000 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 5 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC6-1203Sx-E CC6-1205Sx-E CC6-1212Sx-E CC6-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) % 78 82 85 Current (typ) (*1) A 0.423 0.610 0.588 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. CC6-E MODEL CC6-2403Sx-E CC6-2405Sx-E CC6-2412Sx-E CC6-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 77 81 87 86 Current (typ) (*1) A 0.214 0.309 0.287 0.291 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC6-4803Sx-E CC6-4805Sx-E CC6-4812Sx-E CC6-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) % 77 81 86 Current (typ) (*1) A 0.107 0.154 0.145 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 1.200 0.500 0.400 0.250 0.200 Maximum Power (*2) W 3.96 6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Voltage Adjustable Range Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 5.8 Mechanical Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. 12 13 CC6-E Outline Drawing CC6-xxxxxF-E (DIP type) 21.1±0.2 Recommended measurements for mounting board 20.32 2.63 8.5max. 4.0 Shape/Dimensions 10.16 5.08 17.78 15.24 17.87 3.5 t=0.3 5.08 Outer shape of product 7-ø1.0 (land diameter ø2.0) a b 2.7 0.5 2.54 4 5.08 3 7-0.3×0.6 2 22.86 1.0 5 a 5.08 10.16 2-ø1.5 (land diameter ø2.5) 3.5 b 0.5 5.08 (2.93) 2.54 5.08 22.86 2.7 5.08 6 (2.93) 1 Unit: mm Allowable tolerance is ±0.5 if not specified separately. 7 b a CC6-xxxxxR-E (SMD type) 21.1±0.2 (2.93) Recommended measurements for mounting board Outer shape of product 3 4 7-0.3×0.6 3.2 22.0 3.2 28.4 5 10.16 5.08 2 (2.93) 5.08 5.08 1.8 5.08 5.08 (2.93) 1.8 1.2 (18.17) Coplanarity: 0.1 or lower 10.16 22.86 26.16 15.24 t=0.3 5.08 8.8max. 4.0 Shape/Dimensions 5.08 6 1 7 Unit: mm Allowable tolerance is ±0.5 if not specified separately. Connection diagram CC6-xxxxSx-E +Vin 7 –Vin 5 2 3 –Vout 4 NC +Vin +Vin RC –Vin NC –Vout TRM +Vout Terminal connections 7 1 6 RC 5 2 4 3 –Vin Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. +Vout TRM COM –Vout Load RC TRM Load 6 No.1 No.2 No.3 No.4 No.5 No.6 No.7 CC6-xxxxDx-E Load 1 Terminal connections +Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC –Vin –Vout Common out TRM +Vout 14 CC10-E CC10-E Specifications MODEL CC10-0503Sx-E CC10-0505Sx-E CC10-0512Sx-E CC10-0512Dx-E ITEMS/UNITS Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) % 84 83 Current (typ) (*1) A 1.964 2.381 2.286 2.313 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 2.500 2.000 0.800 0.640 0.400 0.320 Maximum Power (*2) W 8.25 10 9.6 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC10-1203Sx-E CC10-1205Sx-E CC10-1212Sx-E CC10-1212Dx-E ITEMS/UNITS Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) % 84 86 88 86 Current (typ) (*1) A 0.318 0.969 1.136 1.047 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 2.500 2.000 1000 800 450 360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. CC10-E MODEL CC10-2403Sx-E CC10-2405Sx-E CC10-2412Sx-E CC10-2412Dx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 84 86 87 86 Current (typ) (*1) A 0.409 0.484 0.575 0.523 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. MODEL CC10-4803Sx-E CC10-4805Sx-E CC10-4812Sx-E CC10-4812Dx-E ITEMS/UNITS Nominal Voltage V DC48 Voltage Range V DC36-76 Input Efficiency (typ) (*1) % 84 86 88 86 Current (typ) (*1) A 0.205 0.242 0.284 0.262 VDC 3.3 5 12 15 12 15 Nominal Voltage Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360 Maximum Power (*2) W 8.25 10 12 10.8 Maximum Line Regulation(Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max) (*4) % 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available ℃ -40 to +85 Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Operating Ambient Humidity Environment % RH 5-95 (the conditions of maximum 38° C in wet bulb temperature and non-condensation should be ensured.) Storage Ambient Humidity Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 10 Mechanical Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25° C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. ・All specifications are subject to change without notice. 15 16 CC10-E Outline Drawing CC10-xxxxxF-E (DIP type) Recommended measurements for mounting board 30.48 25.4 Outer shape of product 5.08 5.08 5.08 18.62 3.5 t=0.3 15.24 4.0 8.5max. 22.6±0.2 10.16 3.38 Shape/Dimensions 7-ø1.0 (land diameter ø2.0) 35.56 25.4 5.08 2-ø1.5 (land diameter ø2.5) 0.5 5.08 a 4 5 6 7-0.3×0.6 1 b a 7 b 2.7 0.5 (3.68) 10.16 2 2.7 3.5 3 b 5.08 5.08 5.08 5.08 (3.68) 35.56 a Unit: mm Allowable tolerance is ±0.5 if not specified separately. 1.0 CC10-xxxxxR-E (SMD type) Shape/Dimensions Recommended measurements for mounting board 1.8 3 4 (3.68) 10.16 2 5 6 7-0.3×0.6 1 3.2 5.08 5.08 5.08 5.08 (3.68) 1.8 7 CC10-xxxxDx-E 7 3 TRM No.1 No.2 No.3 No.4 No.5 No.6 No.7 –Vout 4 NC +Vin +Vin RC –Vin NC –Vout TRM +Vout 7 1 6 RC –Vin 5 2 4 3 Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. Terminal connections +Vout TRM COM –Vout Load –Vin 5 2 Terminal connections +Vout Load 6 RC 3.2 Unit: mm Allowable tolerance is ±0.5 if not specified separately. Load 1 34.6 41.0 Connection diagram CC10-xxxxSx-E +Vin 5.08 5.08 5.08 (18.92) Coplanarity: 0.1 or lower 38.86 Outer shape of product 1.2 35.56 15.24 t=0.3 10.16 8.8max. 4.0 (3.68) 22.6±0.2 No.1 No.2 No.3 No.4 No.5 No.6 No.7 +Vin RC –Vin –Vout Common out TRM +Vout 17 CC15-E CC15-E Specifications MODEL CC15-2403Sx-E CC15-2405Sx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 89 Current (typ) (*1) A 0.695 0.702 VDC 3.3 5 Nominal Voltage Maximum Current A 4.500 3.000 Maximum Power (*2) W 14.85 15 Maximum Line Regulation(Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Output Temperature Coefficient 80mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max)(*3) % +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range Not available Over Current Protection (*5) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 12.5 Mechanical Size (W x H x D) mm DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25° C. (*5) Latch method Resumes by restarting input or resetting remote on/off. ・All specifications are subject to change without notice. 18 CC15-E Outline Drawing CC15-xxxxxSF-E (DIP type) Recommended measurements for mounting board 6.075 27.33 25.4 6.075 37.55 17-0.3×0.6 b a 10.16 2-ø1.5 (land diameter ø2.5) 1.0 b 6.075 31.475 P=2.54 37.55 2.7 17 a 0.5 11 12 13 14 15 16 25-ø1.0 (land diameter ø2.0) 3.5 b Outer shape of product 0.5 a 2.54 10 9 8 7 6 5 4 3 2 1 2.7 22.86 t=0.3 10.16 3.0 (4.62) 2.54 (4.62) P P P P P P P P 4.47 32.1 7.0max. 38.1 P P P P P Shape/Dimensions Unit: mm Allowable tolerance is ±0.5 if not specified separately. CC15-xxxxxSR-E (SMD type) Recommended measurements for mounting board 27.33 2.54 11 12 13 14 15 16 10.16 (4.62) 2.54 (4.62) 10 9 8 7 6 5 4 3 2 1 17-0.3×0.6 10.16 Coplanarity: 0.1 or lower 22.86 t=0.3 40.9 Outer shape of product 3.2 17 1.8 +Vin –Vout Load –Vin Terminal connections 17 16 15 14 13 12 11 +Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 NC NC RC NC NC +Vin +Vin –Vin –Vin No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 NC NC +Vout +Vout +Vout –Vout –Vout NC Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. 3.2 P=2.54 Unit: mm Allowable tolerance is ±0.5 if not specified separately. Connection diagram 1 2 3 4 5 6 7 8 9 10 36.6 43.0 1.8 RC P P P P P 7.5max. 32.1 1.2 38.1 P P P P P P P P P 4.47 Shape/Dimensions 19 CC25-E CC25-E Specifications MODEL CC25-2403Sx-E CC25-2405Sx-E ITEMS/UNITS Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) % 90 Current (typ) (*1) A 1.146 1.157 VDC 3.3 5 Nominal Voltage Maximum Current A 7.500 5.000 Maximum Power (*2) W 24.75 25 Maximum Line Regulation (Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Output Temperature Coefficient 80mV (Ambient temperature -40℃ to +50℃ ) Max Power Total Regulation (max)(*3) % +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range VDC Not available Over Current Protection (*5) Available Not available Function Over Voltage Protection Remote ON/OFF Control Available Operating Ambient Temperature ℃ -40 to +85 Storage Ambient Temperature ℃ -40 to +85 Operating Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity % RH 5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Between input terminal and output terminal: 500VDC, 50MΩ min Isolation Resistance Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 20 Mechanical Size (W x H x D) mm DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9 Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25° C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25° C. (*2) The maximum output power value is between -40° C and +50° C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25° C. (*5) Latch method Resumes by restarting input or resetting remote on/off. ・All specifications are subject to change without notice. 20 CC25-E Outline Drawing CC25-xxxxSF-E (DIP type) Shape/Dimensions Recommended measurements for mounting board 43.2 30.5 5.08 PPPPP 6.075 6.075 6 5 4 3 2 1 35.56 PPP 6.075 36.575 42.65 P=2.54 25 b a Unit: mm Allowable tolerance is ±0.5 if not specified separately. Recommended measurements for mounting board 43.2 7.5max. 4.52 44.9 Outer shape of product 35.56 40.08 (4.67) 48.1 25 Terminal connections –Vout No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 Load 25 24 23 22 21 20 19 18 17 16 15 14 3.2 P=2.54 Unit: mm Allowable tolerance is ±0.5 if not specified separately. Connection diagram 1 2 RC 3 4 5 –Vin 6 7 8 9 10 11 12 +Vin 13 41.7 3.2 (4.67) 6 5 4 3 2 1 PPP 9 8 7 14 15 16 17 18 19 20 21 22 23 24 10.16 13 12 11 10 P P P P P P P P P P 10.16 Coplanarity: 0.1 or lower 1.8 5.08 PP 46.0 5.08 PPPPP t=0.3 1.8 5.08 2-ø1.5 (land diameter ø2.5) 2.7 Shape/Dimensions 5.08 5.08 PP 1.0 a CC25-xxxxSR-E (SMD type) 2.54 25-ø1.0 (land diameter ø2.0) 10.16 9 8 7 25-0.3×0.6 2.7 b 3.5 14 15 16 17 18 19 20 21 22 23 24 0.5 b 0.5 a (4.67) 13 12 11 10 40.08 42.65 P P P P P P P P P P 10.16 Outer shape of product t=0.3 (4.67) 2.54 5.08 5.08 3.0 7.0max. 4.52 44.9 +Vout NC NC NC RC NC NC –Vin –Vin –Vin No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 No.18 +Vin +Vin +Vin NC NC +Vout +Vout +Vout +Vout No.19 No.20 No.21 No.22 No.23 No.24 No.25 Derating Curve Output power (%) 100 Natural air cooling 80 a b 60 40 20 a:0.5m/s(100LFM) b:1m/s(200LFM) 0 -40 -20 0 20 40 60 80 100 Ambient temperature (° C) Output power derating by ambient temperature (common specification) ・All specifications are subject to change without notice. –Vout –Vout –Vout –Vout –Vout –Vout NC 21 CC-E CC-E Instruction Manual 1. Control functions/Protection functions/Connections 1. Remote On/Off terminal (RC) 1.5-10W type Open collector is recommended as the connection system. Consult us for use with other systems. Use a transistor with "VCE: Vin or over" and "Ic: 1mA or over". Output is switched off by setting the RC terminal open, and switched on by setting the RC terminal to LOW (0-0.4V). +Vout DIP/SMDmodels Load RC –Vout When not using this function (always on), short-circuit between RC terminal and -Vin terminal. +Vout Load +Vin Load +Vin –Vin –Vout –12V +15V +Vout Load TRM COM –Vin Load –Vout –15V SIPmodels Model name CC3–xx03SS–E CC3–xx05SS–E CC3–xx12SS–E CC3–xx12DS–E Model name 3.3V 5V 12V ±12V Connection to -Vout 3.67V 6V 15V ±15V Fig. 3 3 3 4 Load Load 3.3V, 5V, 12V +Vin –Vin TRM –Vout +Vout +Vin –Vin Fig.3 3.67V, 6V, 15V Load Load Load –12V +15V Load –15V +Vin –Vin TRM –Vout COM +Vout +Vin COM +Vout Fig.4 +12V ・All specifications are subject to change without notice. Load –Vout –Vout Load –Vout +Vin Load TRM COM –Vout +Vout +12V +Vout +Vout Load –Vout RC –Vin TRM –Vout –Vin +Vout RC +Vin 3.6V 6V 15V +Vout Fig.2 When not using this function (always on), set the RC terminal to open. When not using this function (always on) +Vin Load TRM Output is switched on by setting the RC terminal to open, and switched off by setting the RC terminal to HIGH (connecting to Vin terminal). –Vin 3.3V 5V 12V +Vout –Vout 15/25W type RC control signal Fig. 1 1 1 2 To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. –Vin +Vin Connection to -Vout 3.6V 6V 15V ±15V Fig.1 RC –Vin Open 3.3V 5V 12V ±12V –Vin +Vin When not using this function (always on) Model name CC –xx03Sx–E CC –xx05Sx–E CC –xx12Sx–E CC –xx12Dx–E TRM –Vin Output voltage can be set to the values shown in the figure below by connecting the TRM terminal to the -Vout terminal. When not using this function (always on), set the TRM terminal to open. Note that when the output voltage is set high by this function, derating of output current is necessary according to the maximum power. TRM +Vin RC control signal 1-2. Output voltage adjusting terminal (TRM) (1.5-10W type) 22 CC-E For the ±12V output model, 24V single output by making the COM terminal and TRM Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low terminal open. And output voltage can be set to 30V single *5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb ≧ 62] output by making the COM terminal open and connecting *6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb ≧ 160] the TRM terminal to the -Vout terminal. *7 Vout = 12.01 - 431.1/(57+Rb) [Rb ≧ 620] *8 Vout = 12.02 - 968.5/(103+Rb) [Rb ≧ 1500] models Model name COM terminal TRM terminal Single output Fig. Open Open Open Connection to -Vout * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Fig.5 Fig.6 +Vin +Vout 24V +Vout 30V TRM Load COM –Vin +Vin Load TRM COM –Vin –Vout –Vout Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low *5 Rb = 15.53/(3.3-Vout) - 39.6 *6 Rb = 52.55/(5.01-Vout) - 31.8 *7 Rb = 431.1/(12.01-Vout) - 57 *8 Rb = 968.5/(12.02-Vout) - 103 models Model name COM terminal TRM terminal Single output Fig. Open Open Open Connection to -Vout +Vin –Vin TRM –Vout COM +Vout +Vin –Vin TRM –Vout Fig.8 COM +Vout Fig.7 Calculating connected resistance Ra, Rb (kΩ) from set output voltage Vout (V) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high *1 Ra = 9.59/(Vout-3.3) - 32 *2 Ra = 17.64/(Vout-5.01) - 17.8 *3 Ra = 50.53/(Vout-12.01) - 16.9 *4 Ra = 53.55/(Vout-12.02) - 18 Fig.9 Fig.10 3.3∼3.6V 5∼6V 12∼15V +Vout 30V TRM Ra 1-3. Output voltage adjusting function (adding external resistance) (1.5-10W type) Output voltage can be varied in the range shown in the figure below by connecting a resistance (Ra, Rb) between the TRM terminal and the -Vout terminal or between the TRM terminal and +Vout terminal. Note that when the output voltage is set high, derating of output current is necessary according to the maximum power. models Model name Connection between Fig. -Vout and Ra to to to to Connection between Fig. +Vout and Rb to to to to * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Calculating output voltage Vout (V) from connected resistance Ra, Rb (kΩ) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high *1 Vout = 3.3 + 9.59/(32+Ra) *2 Vout = 5.01 + 17.64/(17.8+Ra) *3 Vout = 12.01 + 50.53/(16.9+Ra) *4 Vout = 12.02 + 53.55/(18+Ra) ・All specifications are subject to change without notice. Rb TRM –Vout 3.15∼3.3V 4.75∼5V 11.4∼12V Load Load 24V Load Load *5, *6, *7 +Vout –Vout *1, *2, *3 Fig.11 Fig.12 +12∼+15V +Vout Load TRM COM –Vout *8 +Vout TRM Rb +11.4∼+12V Load COM Ra *4 Load –12∼–15V Load –Vout –11.4∼–12V models Connection between Connection between Fig. Fig. -Vout and Ra +Vout and Rb to to to to to to to to * To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. Model name Calculating output voltage Vout (V) from connected resistance Ra, Rb (kΩ) Adding a resistance Ra between TRM terminal and -Vout terminal, to set the output voltage high *1 Vout = 3.3 + 1.04/(2.83+Ra) *2 Vout = 5 + 12.75/(12.69+Ra) *3 Vout = 12 + 48.4/(16.18+Ra) *4 Vout = 12 + 54.7/(18+Ra) Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low *5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb ≧ 7.6] *6 Vout = 5 - 12.78/(17.79+Rb) [Rb ≧ 33.3] *7 Vout = 12 - 184.1/(35.54+Rb) [Rb ≧ 271.3] *8 Vout = 12 -470.3/(61.75+Rb) [Rb ≧ 722.1] 23 CC-E Calculating connected resistance Ra, Rb (kΩ) from set output voltage Vout (V) 1-5. Over voltage protection Adding a resistance Ra between TRM terminal and -Vout An over voltage protection function is not incorporated in terminal, to set the output voltage high the model. Be careful if an external voltage over the nomi- *1 Ra = 1.04/(Vout-3.3) - 2.83 nal voltage is applied, damage may be caused. *2 Ra = 12.75/(Vout-5) - 12.69 *3 Ra = 48.4/(Vout-12) - 16.18 *4 Ra = 54.7/(Vout-12) - 18 1-6. Low input voltage protection Adding a resistance Rb between TRM terminal and +Vout terminal, to set the output voltage low *5 Rb = 1.69/(3.3-Vout) - 3.66 *6 Rb = 12.78/(5-Vout) - 17.79 *7 Rb = 184.1/(12-Vout) - 35.54 *8 Rb = 470.3/(12-Vout) - 61.75 *5, *6, *7 Load 3.15∼3.3V、4.75∼5V、11.4∼12V Ra *4 Load Load +12∼+15V –12∼–15V TRM –Vout COM +Vout TRM –Vout Fig.16 COM +Vout TRM Rb Ra *1, *2, *3 Load 3.3∼3.67V、5∼6V、12∼15V Fig.15 –Vout TRM –Vout +Vout Fig.14 +Vout Fig.13 Rb Load Load +11.4∼+12V *8 –11.4∼–12V 1-4. Over current protection 1.5-10W type An over current protection circuit is incorporated in the model, and if over current occurs, the output voltage is lowered. By removing the over current and shorted conditions, the output voltage automatically resumes. Note that if the over current status continues for 30 seconds or over, the internal elements of the converter may be deteriorated or damaged. The current value, from which it is judged as an over current, is not to be lower than the nominal current value. Due to fold back characteristics of OCP, the output may not rise up steady with constant current load or inductive load. This series is equipped with the low input voltage protection in order to prevent malfunction due to low input voltage. The converter stops operation if the input voltage become lower than the set voltage. The set ranges are shown in the table below. Model name Input voltage range Voltage range set for protection circuit to to to to to to to to to to to to To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names. The above setting value is fixed and cannot be adjusted externally. 1-7. Insulation withstand voltage The insulation withstand voltage between input and output, and between terminal and case, is AC500V. 1-8. Series/Parallel connections Series connection Serial connection is applicable by wiring as shown in the figure below (left). If output voltage is not generated by this connection, connect a Schottky barrier diode in which the forward voltage is possibly low. Also note that the Schottky barrier diode should have a reverse voltage that is twice or over the value of the voltage between +Vout and -Vout. And the output current should be the same or lower than the nominal current value, whichever is smaller in the converters. +Vin +Vout 15/25W type –Vin –Vout –Vin –Vout An over current protection circuit is incorporated in the model, and if over current occurs, the output voltage is lowered and the converter is stopped and latched. The output voltage does not automatically resume even after removing the over current and shorted conditions. To resume output voltage, restart input or reset remote on/ off. The current value, from which it is judged as an over current, is not to be lower than the nominal current value. +Vin +Vout +Vin +Vout –Vin –Vout –Vin –Vout ・All specifications are subject to change without notice. Parallel connection Parallel connection is not applicable. Load +Vout Load +Vin 24 CC-E 2. Noise reduction methods 2-1. Output ripple noise measurement method 2-3. Output ripple & noise The measured value of the converter noise may differ de- To reduce Output ripple & noise, connect a capacitor to pending on the measurement method. Measurement should be conducted in a position close to the output terminal. When connecting a prove, do not allow a loop to be configured in order not to pick up flux. As well, note that the spike voltage greatly differs depending on the ripple voltmeter and frequency band of the oscilloscope. Our noise measurement is conducted by the wiring shown the output of the converter. In addition, reduction can be enhanced if a π type filter is incorporated as shown in the figure below. In this case, use of a coil with around 100µH is recommended. Iin A lout V V Vout Load Vin 0.1µF –Vout 50Ω coaxial cable 1.5m –Vin A –Vout +Vout –Vin –Vout 20mm +Vout +Vin –Vin +Vin Load 10mm +Vout Load in the figure below and in the frequency band of 50MHz. +Vin Ripple voltmeter 50MHz +Vin +Vout 1 F 2-2. Input ripple noise –Vin Load Oscilloscope or 50MHz End-point: 50Ω+0.1µF When the distance to the load from the output of the converter is long, connect the capacitor as close as possible to the load. To reduce output spike noise, connect a ceramic capacitor with around 1µF to the output of the converter. –Vout This series is equipped with a built-in capacitor for input. However, by connecting a capacitor with around 10 µF, input ripple noise and input return noise can be reduced. –Vin –Vout +Vin +Vout –Vin –Vout Load +Vout Load +Vin When the distance to the input of the converter from the input power supply is long, attach a capacitor as close as possible to the input terminal. +Vout –Vin –Vout Load +Vin When the distance to the input of the converter from the input power supply is long, the impedance of the input line can become high, causing high spike noise. In this case, it is recommended to connect a capacitor as close as possible to the input of the DC-DC converter. ・All specifications are subject to change without notice. 2-4. Capacity of external capacitor connected to output Note that if a capacitor with capacity over the value shown in the table below is connected to the output, or several capacitors with low impedance are connected in parallel, operation of the converter may become unstable. Model name Electrostatic capacitance (µF) max. 25 CC-E 2-5. Common mode noise 2-6. Radiation noise For products other than with 10W, capacitors are not con- Radiation noise of the converter can be reduced by con- nected between the primary GND and the secondary GND. necting the case terminal to the input or output GND ter- To reduce common mode noise, connect a capacitor with minal. The effectiveness varies depending on the device. around 1000pF between the primary GND and the secondary GND, as shown in the figure below. In this case, note that if the capacitor that is connected is too large, coupling capacitance between input and output becomes large. Also be careful about the withstand voltage of the capacitor (500V or over is desirable with consideration of the insula- Check it on the actual device. Regarding wiring, use GND line and solid pattern for the bottom of the converter as much as possible. - SMD models are not equipped with case terminals. tion withstand voltage). +Vout –Vin –Vout Load +Vin For products with 10W, capacitors with 1000pF are internally connected between primary and secondary. 3. Soldering conditions/Cleaning conditions 3-1. Soldering conditions ●Soldering conditions DIP models / SIP models Observe the following conditions in soldering board. Solder dip Soldering copper 260°C, 10s max., 1 time 380°C, 3s max., 1 time/PIN SMD models Lead-free soldering / High-temperature reflow process Surface temperature of parts 30 20s 245˚C max. 225˚C min. 3-2. Cleaning method Board cleaning after soldering is not recommended. However, the cleaning fluids and conditions shown in the table below have been tested and proved to have no problem. These fluids and conditions can be used. Cleaning fluids and test conditions Cleanthrough 750H (1) Cleaning (shaking) at 60° C for 4 minutes (2) Rinsing (shaking in water) at 60° C for 4 minutes (3) Rinsing (shaking in water) at ordinary temperature 40° C for 4 minutes (4) Drying at 70° C for 6 minutes 180˚C 150˚C 1 to 3˚C/s 40 to 100s 1 to 4˚C/s 1 to 5˚C/s The reflow must be 1 time only. (Do not reflow with the on-board module on the motherboard underside.) Pine alpha ST100S (1) Cleaning (shaking) at 60° C for 5 minutes (2) Rinsing (shaking in water) at 30° C for 3 minutes (3) Drying at 70° C for 6 minutes Terpene Cleaner EC-7R (1) Cleaning (shaking) at 60° C for 5 minutes (2) Rinsing (shaking in IPA) at 30° C for 10 minutes (3) Drying at 70° C for 6 minutes Isopropyl alcohol (1) Ultrasonic waves at 60° C for 1 minute (2) Cool bath cleaning R.T. for 1 minute (3) Vapor cleaning at 83° C for 1 minutes Asahiklin AK-225AES (1) Ultrasonic waves at 50° C for 2 minutes (2) Cool bath cleaning R.T. for 2 minutes ・All specifications are subject to change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Create Date : 2017:10:12 04:43:42+09:00 Creator : Adobe InDesign CS4_J (6.0.6) Modify Date : 2017:10:20 14:58:58+09:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Instance ID : uuid:5bb4e664-ef4b-4dde-bddd-a9572b39e230 Document ID : xmp.did:6D8DFE34DD24E511A461B653B8D2EF37 Original Document ID : adobe:docid:indd:fe86c10a-63c4-11e1-8eda-9c6383d50538 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:6C8DFE34DD24E511A461B653B8D2EF37 Derived From Document ID : xmp.did:CDBD566BB7FCE311AE59AB72ABC97353 Derived From Original Document ID: adobe:docid:indd:fe86c10a-63c4-11e1-8eda-9c6383d50538 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:7ABEC9E15211E211BCBF91DA050B1312, xmp.iid:7BBEC9E15211E211BCBF91DA050B1312, xmp.iid:7CBEC9E15211E211BCBF91DA050B1312, xmp.iid:7DBEC9E15211E211BCBF91DA050B1312, xmp.iid:7EBEC9E15211E211BCBF91DA050B1312, xmp.iid:7FBEC9E15211E211BCBF91DA050B1312, xmp.iid:80BEC9E15211E211BCBF91DA050B1312, xmp.iid:81BEC9E15211E211BCBF91DA050B1312, xmp.iid:82BEC9E15211E211BCBF91DA050B1312, xmp.iid:83BEC9E15211E211BCBF91DA050B1312, xmp.iid:AB042DFC8C11E211BCBF91DA050B1312, xmp.iid:77F4301B9D12E211A837B6D8362C01C2, xmp.iid:1ABDFD7D5019E211929B9838D0BC3A3E, xmp.iid:7373434AB519E211A8C3B7B080372E90, xmp.iid:2C64D02FD81CE2119181C5575BF14E22, xmp.iid:2D64D02FD81CE2119181C5575BF14E22, xmp.iid:2E64D02FD81CE2119181C5575BF14E22, xmp.iid:CCBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CDBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CEBD566BB7FCE311AE59AB72ABC97353, xmp.iid:CFBD566BB7FCE311AE59AB72ABC97353, xmp.iid:D0BD566BB7FCE311AE59AB72ABC97353, xmp.iid:D1BD566BB7FCE311AE59AB72ABC97353, xmp.iid:071A9C5FBE1DE511AC16AEC844A5D0C2, xmp.iid:081A9C5FBE1DE511AC16AEC844A5D0C2, xmp.iid:6C8DFE34DD24E511A461B653B8D2EF37, xmp.iid:6D8DFE34DD24E511A461B653B8D2EF37, xmp.iid:BBDE857C1447E71183AAB600697B5B8B, xmp.iid:BCDE857C1447E71183AAB600697B5B8B, xmp.iid:BDDE857C1447E71183AAB600697B5B8B, xmp.iid:198AAEB15649E711AB48E6E96362EE39, xmp.iid:1A8AAEB15649E711AB48E6E96362EE39, xmp.iid:E2AB68FCE44AE71181DBCA9E9CD1EC74, xmp.iid:E3AB68FCE44AE71181DBCA9E9CD1EC74, xmp.iid:E7DC99DD4CA8E711844FD3150BCA53D0, xmp.iid:F0ED4F293CA9E711B528A11A366557D8, xmp.iid:F1ED4F293CA9E711B528A11A366557D8, xmp.iid:01ED2473BCAEE7118407B5DA40B92427 History When : 2012:10:08 23:17:24+09:00, 2012:10:08 23:17:24+09:00, 2012:10:09 03:14:29+09:00, 2012:10:09 05:03:44+09:00, 2012:10:09 05:22:35+09:00, 2012:10:09 05:54:51+09:00, 2012:10:09 06:02:26+09:00, 2012:10:09 06:03:25+09:00, 2012:10:09 06:09:09+09:00, 2012:10:09 06:10:37+09:00, 2012:10:09 06:13:19+09:00, 2012:10:10 14:41:14+09:00, 2012:10:19 03:20:27+09:00, 2012:10:19 15:21:59+09:00, 2012:10:23 15:09:21+09:00, 2012:10:23 15:09:21+09:00, 2012:10:23 15:09:50+09:00, 2014:06:26 07:24:06+09:00, 2014:06:26 07:24:06+09:00, 2014:06:26 07:45:19+09:00, 2014:06:26 08:29:41+09:00, 2014:06:26 08:36:51+09:00, 2014:06:26 08:37:22+09:00, 2015:06:29 02:51:58+09:00, 2015:06:29 02:57:15+09:00, 2015:07:08 04:56:36+09:00, 2015:07:08 04:56:36+09:00, 2017:06:02 06:51:37+09:00, 2017:06:02 07:50:26+09:00, 2017:06:02 07:51:56+09:00, 2017:06:05 05:16:37+09:00, 2017:06:05 05:31:34+09:00, 2017:06:07 04:29:02+09:00, 2017:06:07 05:29:01+09:00, 2017:10:04 05:26:32+09:00, 2017:10:05 04:42:31+09:00, 2017:10:05 05:55:04+09:00, 2017:10:12 04:43:26+09:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0 History Changed : /, /metadata, /, /, /, /, /, /, /, /, /, /, /, /, /metadata, /, /, /metadata, /;/metadata, /, /, /, /, /, /, /metadata, /, /, /, /, /, /, /, /, /, /, /, / Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:f57c3eb0-1092-401d-a064-28eba9c7a769, uuid:8739bf62-05bf-41fb-9e47-10c12a321b12, uuid:28b981aa-dcf8-4e2e-9142-89b48c529876, uuid:9596c852-eae6-411e-a839-ddad8e439b86, uuid:607043c8-5b7d-4b56-8054-9a42fbc7e965, uuid:3e81ccbd-c3e5-4bf0-983a-43c418a80806, uuid:0a5cac5e-dfed-4930-b9f6-4c90930ed230, uuid:0d4a51c9-482d-4ca7-8022-f6e6bd50b880, uuid:1b86b07a-9bfe-4758-8186-ff9200c97b0f, uuid:f8a32fa0-ef1b-445c-b69e-5f786c381c0a, uuid:fdba2883-e66c-4eeb-95ae-2a0d9f048343, uuid:05ad283c-e243-4ff2-87bd-5dc0ef39964f, uuid:3269698f-a049-48a0-a5f1-cecbe8b5f4d2, uuid:f59a128d-c7a6-4986-b802-d9f60106ff76, uuid:28366666-e139-410e-a86c-7e7916614676, uuid:dcbf596b-58db-42e4-9511-b901704a0018, uuid:0813824c-3383-455b-b091-e9a44e5af66f, uuid:0476f86c-8f4d-4f81-9178-b6d324ae1658, uuid:75d489c0-ce00-4e48-b733-620e8e78f2f6, uuid:8abc58e7-5ab4-4d6c-9b71-bca062c24c99, uuid:0a504583-6d1a-4eac-9665-fce81ac9dbb8, uuid:0ef003a8-9012-4b37-886b-93e3eaa92b52, uuid:89688754-6032-42bb-b392-385bf1d300ef, uuid:ee637aa6-ed10-44c7-a91f-7fbc8d61fb12, uuid:f2fd14fe-0f87-4de6-8bc4-ee1b692f238a Manifest Reference Document ID : xmp.did:CE4D6991B8FBE311AB55BD2B47BE6733, xmp.did:8A9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8B9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8C9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8D9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8E9CBF9C31FAE3119632F11A9D872FC4, xmp.did:8F9CBF9C31FAE3119632F11A9D872FC4, xmp.did:909CBF9C31FAE3119632F11A9D872FC4, xmp.did:919CBF9C31FAE3119632F11A9D872FC4, xmp.did:4E4670256DFBE311B2C7FE1C05E13361, xmp.did:4F4670256DFBE311B2C7FE1C05E13361, xmp.did:504670256DFBE311B2C7FE1C05E13361, xmp.did:524670256DFBE311B2C7FE1C05E13361, xmp.did:534670256DFBE311B2C7FE1C05E13361, xmp.did:544670256DFBE311B2C7FE1C05E13361, xmp.did:554670256DFBE311B2C7FE1C05E13361, xmp.did:564670256DFBE311B2C7FE1C05E13361, xmp.did:574670256DFBE311B2C7FE1C05E13361, xmp.did:0C1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0D1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0E1D46B06FFBE311B2C7FE1C05E13361, xmp.did:0F1D46B06FFBE311B2C7FE1C05E13361, xmp.did:101D46B06FFBE311B2C7FE1C05E13361, xmp.did:111D46B06FFBE311B2C7FE1C05E13361, xmp.did:121D46B06FFBE311B2C7FE1C05E13361 Metadata Date : 2017:10:20 14:58:58+09:00 Creator Tool : Adobe InDesign CS4_J (6.0.6) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 14029 bytes, use -b option to extract) Doc Change Count : 587 Format : application/pdf Producer : Adobe PDF Library 9.0 Trapped : False Page Count : 25EXIF Metadata provided by EXIF.tools