CC3 Cc E
User Manual: CC3
Open the PDF directly: View PDF .
Page Count: 25
・All specifications are subject to change without notice.
1
CC3-0505SF-E
■ Features
●Mounting area halved compared to existing products
●Nonuse of tantalum capacitor or aluminum electro-
lytic capacitor
●Remote On/Off function incorporated in all series of
products
●5-side metal-shielded low noise design
●Lightweight design with no resin filled up
itrevPISdnagnitnuomDMS,noitresniPIDstroppuS● -
cal insertion (3W products)
●Approved by UL60950-1, CSA C22.2 No.60950-1
(C-UL), and EN60950-1 (NEMKO)
CC-E
■ Product Line up
Insulation type DC-DC converter
■ Applications
■ Model-naming method
Shape
Symbol for number of outputs
S: Single output, D: Dual outputs
Nominal output voltage
03: 3.3V, 05: 5V, 12: 12V
Nominal input voltage
05: 5V, 12: 12V, 24: 24V, 48: 48V
Maximum output power
1R5: 1.5W, 3: 3W, 6:6W
10: 10W, 15: 15W, 25: 25W
Representing series name by
combination with "-E"at the end
Output
power
Input
voltage
Model name
(output voltage: 3.3V)
Model name
(output voltage: 5V)
Model name
(output voltage: 12V/15V)
Model name
Output current
DIP type SMD type SIP type
Output current
DIP type SMD type SIP type
Output current
DIP type SMD type SIP type
Output current
DIP type SMD type SIP type
1.5W
5V 0.4A
CC1R5-0503SF-E CC1R5-0503SR-E -
0.3A
CC1R5-0505SF-E CC1R5-0505SR-E -
0.125A (0.1A)
CC1R5-0512SF-E CC1R5-0512SR-E -
0.06A (0.05A)
CC1R5-0512DF-E CC1R5-0512DR-E -
12V 0.4A
CC1R5-1203SF-E CC1R5-1203SR-E -
0.3A
CC1R5-1205SF-E CC1R5-1205SR-E -
0.125A (0.1A)
CC1R5-1212SF-E CC1R5-1212SR-E -
0.06A (0.05A)
CC1R5-1212DF-E CC1R5-1212DR-E -
24V 0.4A
CC1R5-2403SF-E CC1R5-2403SR-E -
0.3A
CC1R5-2405SF-E CC1R5-2405SR-E -
0.125A (0.1A)
CC1R5-2412SF-E CC1R5-2412SR-E -
0.06A (0.05A)
CC1R5-2412DF-E CC1R5-2412DR-E -
48V 0.4A
CC1R5-4803SF-E CC1R5-4803SR-E -
-
0.3A
CC1R5-4805SF-E CC1R5-4805SR-E -
0.125A (0.1A)
CC1R5-4812SF-E CC1R5-4812SR-E -
0.06A (0.05A)
CC1R5-4812DF-E CC1R5-4812DR-E -
3W
5V 0.8A
CC3-0503SF-E CC3-0503SR-E CC3-0503SS-E
0.6A
CC3-0505SF-E CC3-0505SR-E CC3-0505SS-E 0.25A (0.2A) CC3-0512SF-E CC3-0512SR-E CC3-0512SS-E
0.125A (0.1A)
CC3-0512DF-E CC3-0512DR-E CC3-0512DS-E
12V 0.8A
CC3-1203SF-E CC3-1203SR-E CC3-1203SS-E
0.6A
CC3-1205SF-E CC3-1205SR-E CC3-1205SS-E 0.25A (0.2A) CC3-1212SF-E CC3-1212SR-E CC3-1212SS-E
0.125A (0.1A)
CC3-1212DF-E CC3-1212DR-E CC3-1212DS-E
24V 0.8A
CC3-2403SF-E CC3-2403SR-E
0.6A
CC3-2405SF-E CC3-2405SR-E CC3-2405SS-E 0.25A (0.2A) CC3-2412SF-E CC3-2412SR-E CC3-2412SS-E
0.125A (0.1A)
CC3-2412DF-E CC3-2412DR-E CC3-2412DS-E
48V 0.8A
CC3-4803SF-E CC3-4803SR-E CC3-4803SS-E
0.6A
CC3-4805SF-E CC3-4805SR-E CC3-4805SS-E 0.25A (0.2A) CC3-4812SF-E CC3-4812SR-E
0.125A (0.1A)
CC3-4812DF-E CC3-4812DR-E CC3-4812DS-E
6W
5V 1.2A
CC6-0503SF-E CC6-0503SR-E -
1A
CC6-0505SF-E CC6-0505SR-E - 0.5A (0.4A) CC6-0512SF-E CC6-0512SR-E -
-
0.25A (0.2A) CC6-0512DF-E CC6-0512DR-E -
12V 1.2A
CC6-1203SF-E CC6-1203SR-E -
1.2A
CC6-1205SF-E CC6-1205SR-E - 0.5A (0.4A) CC6-1212SF-E CC6-1212SR-E - 0.25A (0.2A) CC6-1212DF-E CC6-1212DR-E -
24V 1.2A
CC6-2403SF-E CC6-2403SR-E -
1.2A
CC6-2405SF-E CC6-2405SR-E - 0.5A (0.4A) CC6-2412SF-E CC6-2412SR-E - 0.25A (0.2A) CC6-2412DF-E CC6-2412DR-E -
48V 1.2A
CC6-4803SF-E CC6-4803SR-E -
1.2A
CC6-4805SF-E CC6-4805SR-E - 0.5A (0.4A) CC6-4812SF-E CC6-4812SR-E - 0.25A (0.2A) CC6-4812DF-E CC6-4812DR-E -
10W
5V 2.5A
CC10-0503SF-E CC10-0503SR-E -
2A
CC10-0505SF-E CC10-0505SR-E - 0.8A (0.64A) CC10-0512SF-E CC10-0512SR-E - 0.4A (0.32A) CC10-0512DF-E CC10-0512DR-E -
12V 2.5A
CC10-1203SF-E CC10-1203SR-E -
2A
CC10-1205SF-E CC10-1205SR-E -
1A (0.8A)
CC10-1212SF-E CC10-1212SR-E -
0.45A (0.36A)
CC10-1212DF-E CC10-1212DR-E -
24V 2.5A
CC10-2403SF-E CC10-2403SR-E -
2A
CC10-2405SF-E CC10-2405SR-E -
1A (0.8A)
CC10-2412SF-E CC10-2412SR-E -
0.45A (0.36A)
CC10-2412DF-E CC10-2412DR-E -
48V 2.5A
CC10-4803SF-E CC10-4803SR-E -
2A
CC10-4805SF-E CC10-4805SR-E -
1A (0.8A)
CC10-4812SF-E CC10-4812SR-E -
0.45A (0.36A)
CC10-4812DF-E CC10-4812DR-E -
15W 24V 4.5A
CC15-2403SF-E CC15-2403SR-E -
3A
CC15-2405SF-E CC15-2405SR-E - - - - - - - - -
25W 24V 7.5A
CC25-2403SF-E CC25-2403SR-E -
5A
CC25-2405SF-E CC25-2405SR-E - - - - - - - - -
F: Horizontally-mounted DIP type
R: Horizontally-mounted SMD type
FS Vertically-mounted SIP type
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame retar -
dants, PBB and PBDE, have not been used, except for
exempted applications.
■
Conformity to RoHS Directive
High accuracy of ± 3% in output voltage (10W of
lower single output)
(output voltage: ±12V/±15V)
Low Voltage Directive
UL60950-1/
CSA C22.2 No.60950-1
EN60950-1
Y
E
A
R
S
warranty
5
web171023
・All specifications are subject to change without notice.
2
CC1R5-E Specifications
MODEL
ITEMS/UNITS
CC1R5-0503Sx-E CC1R5-0505Sx-E
CC1R5-0512Sx-E CC1R5-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) %71 77 80 79
Current (typ) (*1) A 0.372 0.390 0.375 0.380
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E CC1R5-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) %73 78 82 81
Current (typ) (*1) A 0.151 0.160 0.152 0.154
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3±5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Ambient Temperature ℃-40 to +85
Storage Ambient Temperature ℃-40 to +85
Operating Ambient Humidity
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Storage Ambient Humidity
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC1R5-E
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
3
MODEL
ITEMS/UNITS
CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E CC1R5-2412Dx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %72 77 81 79
Current (typ) (*1) A 0.076 0.081 0.077 0.079
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E CC1R5-4812Dx-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) %70 76 80 79
Current (typ) (*1) A 0.039 0.041 0.039 0.040
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC1R5-E
Between input terminal and output terminal: 500VDC, 50MΩ min
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
4
Derating Curve
Recommended measurements for
mounting board
Recommended measurements for
mounting board
Connection diagram
E-xDxxxx-5R1CCE-xSxxxx-5R1CC
16.6±0.2
12.71.905 1.905
t=0.3
8.5max.3.5
(3.22)(3.22)
2.54
7.62
16.51
12.7
4.0
2.545.082.54
3
a b
2
1
7-0.3×0.6
b a
4
5
7
6
2.7
1.0
2.7
0.53.5
0.5
a
b
2.545.082.54
14.605
7.62
10.16
13.08
2.92
16.51
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
16.6±0.2
t=0.3
8.8max.
16.51
4.0
Coplanarity: 0.1 or lower
19.81
1.81.8
(3.22)(3.22)
2.54
7.62
2.545.082.54
3
2
1
4
5
7
6
7-0.3×0.6
2.545.082.54
7.62
10.16
(13.38)
(3.22)
22.0
3.2 3.215.6
1.2
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
17
2
3
5
6
4 NC
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
17
2
3
5
6
4
COM
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
Shape/Dimensions
Shape/Dimensions
Load Load
Load
Outer shape of
product
Outer shape of
product
Outline Drawing
CC1R5-xxxxxF-E (DIP type)
CC1R5-xxxxxR-E (SMD type)
CC1R5-E
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
5
CC3-E Specifications
MODEL
ITEMS/UNITS
CC3-0503Sx-E CC3-0505Sx-E
CC3-0512Sx-E CC3-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) %73 77 82 81
Current (typ) (*1) A 0.723 0.779 0.732 0.741
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) 2.64 3
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 4.5
Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC3-1203Sx-E CC3-1205Sx-E
CC3-1212Sx-E CC3-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) %74 79 82 81
Current (typ) (*1) A 0.297 0.316 0.305 0.309
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 4.5
Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC3-E
(DIP/SMD)
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
6
MODEL
ITEMS/UNITS
CC3-2403Sx-E CC3-2405Sx-E
CC3-2412Sx-E CC3-2412Dx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %73 78 82 81
Current (typ) (*1) A 0.151 0.160 0.152 0.154
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 4.5
Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC3-4803Sx-E CC3-4805Sx-E
CC3-4812Sx-E CC3-4812Dx-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) %73 79 81 80
Current (typ) (*1) A 0.075 0.079 0.077 0.078
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 4.5
Size (W x H x D) mm DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC3-E
(DIP/SMD)
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
7
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagram
E-xDxxxx-3CCE-xSxxxx-3CC
17.78 2.7
45.245.2
(3.22)(3.22)
2.54
7.62
2.545.082.54
3
ab
2
1
7-0.3×0.6
ab
4
5
7
6
1.0
2.7
0.53.5
0.5
a
b
8.5max.
3.5
22.86
17.78
16.6±0.2
t=0.3
4.0
2.545.082.54
20.32
7.62
10.16
13.08
2.92
22.86
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
26.16
8.18.1
(3.22)(3.22)
2.54
7.62
2.545.082.54
3
2
1
7-0.3×0.6
4
5
7
6
8.8max.
22.86
16.6±0.2
t=0.3
4.0
Coplanarity: 0.1 or lower
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
2.545.082.54
7.62
10.16
(13.38)
(3.22)
28.4
3.2 22.0 3.2
1.2
17
2
3
5
6
4 NC
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
17
2
3
5
6
4
COM
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
Shape/Dimensions
Shape/Dimensions
Outer shape of product
Outer shape of product
Load Load
Load
Outline Drawing
CC3-xxxxxF-E (DIP type)
CC3-xxxxxR-E (SMD type)
CC3-E
(DIP/SMD)
Derating Curve
・All specifications are subject to change without notice.
8
CC3-E Specifications
MODEL
ITEMS/UNITS
CC3-0503SS-E CC3-0505SS-E
CC3-0512SS-E CC3-0512DS-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) %73 77 82 81
Current (typ) (*1) A 0.723 0.779 0.732 0.741
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 7
Size (W x H x D) mm 27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC3-1205SS-E CC3-1212SS-E CC3-1212DS-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) %79 82
Current (typ) (*1) A 0.316 0.305
Output
Nominal Voltage
VDC
5 12 15 12 15
Maximum Current A 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 3
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 7
Size (W x H x D) mm 27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC3-E
(SIP)
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
9
MODEL
ITEMS/UNITS
CC3-2403SS-E CC3-2405SS-E
CC3-2412SS-E CC3-2412DS-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %73 78 82 81
Current (typ) (*1) A 0.151 0.160 0.152 0.154
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.800 0.600 0.250 0.200 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.67 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 7
Size (W x H x D) mm 27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC3-4803SS-E CC3-4805SS-E CC3-4812DS-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) %73 79 82
Current (typ) (*1) A 0.075 0.079 0.076
Output
Nominal Voltage
VDC
3.3 5 12 15
Maximum Current A 0.800 0.600 0.125 0.100
Maximum Power (*2) W 2.64 3
Maximum Line Regulation (Within input voltage range)
mV 20 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 7
Size (W x H x D) mm 27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC3-E
(SIP)
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
10
Outline Drawing
CC3-xxxxxS-E (SIP type)
CC3-E
(SIP)
E-SDxxxx-3CCE-SSxxxx-3CC
2.47 P P P P 2P P P P P 6
3.5 (0.5)
4.1
(0.5)
17.9
4
17.78 5.01
2.47
22.86
t=0.25
a
0.5
P=2.54
9.2
9.2
27.8
a
1 2 3 4 5 7 8 9 10
Internal parts mounting space
17.78
2.47 22.86 2.47
27.8
P P P P 2P
P=2.54
PPP
6.0
9.2
9-ø0.8 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
Recommended measurements for mounting board
+Vin
+Vout
TRM
RC
–Vin
+Vin
–Vout
1 2 3 4 5 7 8 9 10
Terminal connections
No.1 +Vout
No.2 NC
No.3 NC
No.4 –Vout
No.5 TRM
No.6 NC
No.7 RC
No.8 –Vin
No.9 +Vin
No.10 +Vin
+Vin
+Vout
COM
COM
TRM
RC
–Vout
1 2 3 4 5 7 8 9 10
–Vin
+Vin
Terminal connections
No.1 +Vout
No.2 COM
No.3 COM
No.4 –Vout
No.5 TRM
No.6 NC
No.7 RC
No.8 –Vin
No.9 +Vin
No.10 +Vin
Shape/Dimensions
Connection diagram
Load Load Load
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Derating Curve
0.51(t=0.3
4
)
・All specifications are subject to change without notice.
11
CC6-E Specifications
MODEL
ITEMS/UNITS
CC6-0503Sx-E CC6-0505Sx-E
CC6-0512Sx-E CC6-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) %76 79 82
Current (typ) (*1) A 1.042 1.266 1.463
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 1.200 1.000 0.500 0.400 0.250 0.200
Maximum Power (*2) W 3.96 5 6
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 5.8
Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC6-1203Sx-E CC6-1205Sx-E
CC6-1212Sx-E CC6-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) %78 82 85
Current (typ) (*1) A 0.423 0.610 0.588
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 1.200 0.500 0.400 0.250 0.200
Maximum Power (*2) W 3.96 6
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 5.8
Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC6-E
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
12
MODEL
ITEMS/UNITS
CC6-2403Sx-E CC6-2405Sx-E
CC6-2412Sx-E CC6-2412Dx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %77 81 87 86
Current (typ) (*1) A 0.214 0.309 0.287 0.291
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 1.200 0.500 0.400 0.250 0.200
Maximum Power (*2) W 3.96 6
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 5.8
Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC6-4803Sx-E CC6-4805Sx-E
CC6-4812Sx-E CC6-4812Dx-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) %77 81 86
Current (typ) (*1) A 0.107 0.154 0.145
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 1.200 0.500 0.400 0.250 0.200
Maximum Power (*2) W 3.96 6
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 5.8
Size (W x H x D) mm DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC6-E
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
13
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagram
E-xDxxxx-6CCE-xSxxxx-6CC
8.5max.3.5
22.86
17.78
21.1±0.2
t=0.3
4.0
45.245.2
(2.93)
5.08
(2.93)10.16
5.085.085.08
3
ab
2
1
7-0.3×0.6
ab
4
5
7
6
2.7
1.0
0.53.5
b
2.7
0.5
a
5.085.085.08
20.32
10.16
15.24
17.87
2.63
22.86
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
8.8max.
22.86
21.1±0.2
t=0.3
4.0
Coplanarity: 0.1 or lower
26.16
8.18.1
(2.93)(2.93)10.16 5.08
5.085.085.08
3
2
1
7-0.3×0.6
4
5
7
6
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
5.085.08
10.16
15.24
(18.17)
(2.93)
5.08
28.4
3.2 22.0 3.2
1.2
17
2
3
5
6
4 NC
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
17
2
3
5
6
4
COM
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
Shape/Dimensions
Shape/Dimensions
Outer shape of product
Outer shape of product
Load Load
Load
Outline Drawing
CC6-xxxxxF-E (DIP type)
CC6-xxxxxR-E (SMD type)
CC6-E
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Derating Curve
・All specifications are subject to change without notice.
14
CC10-E Specifications
MODEL
ITEMS/UNITS
CC10-0503Sx-E CC10-0505Sx-E
CC10-0512Sx-E CC10-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) %84 83
Current (typ) (*1) A 1.964 2.381 2.286 2.313
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 2.500 2.000 0.800 0.640 0.400 0.320
Maximum Power (*2) W 8.25 10 9.6
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 10
Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC10-1203Sx-E CC10-1205Sx-E
CC10-1212Sx-E CC10-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) %84 86 88 86
Current (typ) (*1) A 0.318 0.969 1.136 1.047
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 2.500 2.000 1000 800 450 360
Maximum Power (*2) W 8.25 10 12 10.8
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 10
Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC10-E
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
15
MODEL
ITEMS/UNITS
CC10-2403Sx-E CC10-2405Sx-E
CC10-2412Sx-E CC10-2412Dx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %84 86 87 86
Current (typ) (*1) A 0.409 0.484 0.575 0.523
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360
Maximum Power (*2) W 8.25 10 12 10.8
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 10
Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC10-4803Sx-E CC10-4805Sx-E
CC10-4812Sx-E CC10-4812Dx-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) %84 86 88 86
Current (typ) (*1) A 0.205 0.242 0.284 0.262
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 2.500 2.000 1.000 0.800 0.450 0.360
Maximum Power (*2) W 8.25 10 12 10.8
Maximum Line Regulation(Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) %3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 10
Size (W x H x D) mm DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC10-E
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
16
Shape/Dimensions
Shape/Dimensions
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagram
E-xDxxxx-01CCE-xSxxxx-01CC
8.5max.
3.5
35.56
25.4
22.6±0.2
t=0.3
4.0
25.4 80.580.5
(3.68)(3.68)
5.08
10.16
5.085.085.08
2.7
1.0
2.7
0.53.5 0.5
a
b
3
2
1
7-0.3×0.6
4
5
7
6
a
b
b
a
30.48
3.38
18.62
10.16
15.24
5.085.085.08
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
35.56
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
35.56
22.6±0.2
t=0.3
4.0
38.86
8.18.1
(3.68)(3.68)
5.08
10.16
5.085.085.08
8.8max.
3
2
1
7-0.3×0.6
4
5
7
6
5.085.085.08
1.2
(3.68)
(18.92)
10.16
15.24
41.0
3.2 34.6 3.2
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
17
2
3
5
6
4 NC
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
17
2
3
5
6
4
COM
–Vout
+Vout
TRM
RC
+Vin
–Vin
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
Coplanarity: 0.1 or lower
Outer shape of
product
Load Load
Load
Outer shape of
product
Outline Drawing
CC10-xxxxxF-E (DIP type)
CC10-xxxxxR-E (SMD type)
CC10-E
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Derating Curve
・All specifications are subject to change without notice.
17
CC15-E Specifications
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
CC15-E
MODEL
ITEMS/UNITS
CC15-2403Sx-E CC15-2405Sx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %89
Current (typ) (*1) A 0.695 0.702
Output
Nominal Voltage
VDC
3.3 5
Maximum Current A 4.500 3.000
Maximum Power (*2) W 14.85 15
Maximum Line Regulation(Within input voltage range)
mV 65 100
Maximum Load Regulation (0-100% load)
mV 120 200
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV
Max Power Total Regulation (max) (*3) %+5/-3
Maximum Ripple & Noise (typ/max) (*4)
mVp-p
40/120
Voltage Adjustable Range Not available
Function
Over Current Protection (*5) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance Between input terminal and output terminal: 500VDC, 50MΩ min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 12.5
Size (W x H x D) mm DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
18
Shape/Dimensions Recommended measurements for mounting board
Connection diagram
7.0max.3.0
37.55
25.4
570.6570.6
38.1 32.1
t=0.3
(4.62)(4.62)2.54
2.5410.16
2.7
1.0
2.7
0.53.5
0.5
a
b
10
9
8
7
6
5
4
3
2
1
b a 17
16
15
14
13
12
11
ba
17-0.3×0.6
PPPPPPPP4.47
22.86
27.33
10.16P P P P P
P=2.54
37.55
31.475
6.075
25-ø1.0 (land diameter ø2.0)
Outer shape of product
2-ø1.5 (land diameter ø2.5)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
PPPPPPPP4.47
22.86
27.33
10.16
P
PPPPP
P=2.54
43.0
36.63.2 3.2
1.2
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
7.5max.
40.9
38.1 32.1
t=0.3
(4.62)(4.62)2.54
2.5410.16
10
9
8
7
6
5
4
3
2
117
16
15
14
13
12
11
17-0.3×0.6
1.8 1.8
Coplanarity: 0.1 or lower
1
2
3
4
5
6
7
8
9
10
17
16
15
14
13
12
11 +Vout
–Vout
+Vin
–Vin
RC
Terminal connections
No.1 NC No.10 NC
No.2 NC No.11 NC
No.3 RC No.12 +Vout
No.4 NC No.13 +Vout
No.5 NC No.14 +Vout
No.6 +Vin No.15 –Vout
No.7 +Vin No.16 –Vout
No.8 –Vin No.17 NC
No.9 –Vin
Shape/Dimensions Recommended measurements for mounting board
Outer shape of product
Load
CC15-E
Outline Drawing
CC15-xxxxxSF-E (DIP type)
CC15-xxxxxSR-E (SMD type)
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Derating Curve
・All specifications are subject to change without notice.
19
CC25-E Specifications
MODEL
ITEMS/UNITS
CC25-2403Sx-E CC25-2405Sx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) %90
Current (typ) (*1) A 1.146 1.157
Output
Nominal Voltage
VDC
3.3 5
Maximum Current A 7.500 5.000
Maximum Power (*2) W 24.75 25
Maximum Line Regulation (Within input voltage range)
mV 65 100
Maximum Load Regulation (0-100% load)
mV 120 200
Temperature Coefficient
(Ambient temperature -40℃ to +50℃)
80mV
Max Power Total Regulation (max) (*3) %+5/-3
Maximum Ripple & Noise (typ/max) (*4)
mVp-p
40/120
Voltage Adjustable Range
VDC
Not available
Function
Over Current Protection (*5) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
℃-40 to +85
℃-40 to +85
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
%RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 20
Size (W x H x D) mm DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
CC25-E
Between input terminal and output terminal: 500VDC, 50MΩ min
Operating Ambient Temperature
Storage Ambient Temperature
Operating Ambient Humidity
Storage Ambient Humidity
・All specifications are subject to change without notice.
20
Shape/Dimensions Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagram
7.0max.3.0
42.65
30.5
570.6570.6
43.2 44.9
t=0.3
5.08 5.082.54
(4.67)
10.16
10
9
8
7
6
5
4
3
2
1
ab
ba
25-0.3×0.6
13
12
11
14
15
16
17
18
19
20
21
22
23
24
25
(4.67)
b
a
2.7
1.0
2.7
0.53.5
0.5
10.16
P P P P P
P P P P P P P P P P
PP P P P 4.52
5.08
35.56
40.08
P=2.54
36.575
42.65
6.075
25-ø1.0 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
5.08
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
7.5max.
46.0
43.2 44.9
t=0.3
Coplanarity: 0.1 or lower
Outer shape of product
1.8 1.8
5.08 5.082.54
(4.67)
10.16
10
9
8
7
6
5
4
3
2
1
13
12
11
14
15
16
17
18
19
20
21
22
23
24
25
(4.67)
10.16P P P P P P P P P P
P=2.54
41.7
3.23.2
48.1
P P P P P PP P P P 4.52
5.08
35.56
40.08
5.08
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
+Vout
–Vout
–Vin
+Vin
Load
4
5
6
7
8
9
10
11
12
13
1
2
3
25
24
23
22
21
20
19
18
17
16
15
14
RC
Terminal connections
No.1 NC No.10 +Vin No.19 –Vout
No.2 NC No.11 +Vin No.20 –Vout
No.3 NC No.12 +Vin No.21 –Vout
No.4 RC No.13 NC No.22 –Vout
No.5 NC No.14 NC No.23 –Vout
No.6 NC No.15 +Vout No.24 –Vout
No.7 –Vin No.16 +Vout No.25 NC
No.8 –Vin No.17 +Vout
No.9 –Vin No.18 +Vout
Shape/Dimensions
Outer shape of product
Outline Drawing
CC25-xxxxSF-E (DIP type)
CC25-xxxxSR-E (SMD type)
ab
Ambient temperature (°C)
Output power (%)
a:0.5m/s(100LFM)
b:1m/s(200LFM)
Natural air cooling
-40 -20
0
20
40 60 80
100
100
80
60
40
20
0
Output power derating by ambient temperature
(common specification)
Derating Curve
CC25-E
CC-E
・All specifications are subject to change without notice.
21
CC-E Instruction Manual
1. Remote On/Off terminal (RC)
1.5-10W type
Open collector is recommended as the connection system.
Consult us for use with other systems.
Use a transistor with "VCE: Vin or over" and "Ic: 1mA or
over".
Output is switched off by setting the RC terminal open, and
switched on by setting the RC terminal to LOW (0-0.4V).
RC
control
signal
+Vin +Vout
–Vin –Vout
RC
Load
When not using this function (always on), short-circuit be-
tween RC terminal and -Vin terminal.
+Vin +Vout
–Vin –Vout
RC
When not
using this
function
(always on)
Load
15/25W type
Output is switched on by setting the RC terminal to open,
and switched off by setting the RC terminal to HIGH (con-
necting to Vin terminal).
RC
control
signal
+Vin +Vout
–Vin –Vout
RC
Load
When not using this function (always on), set the RC termi-
nal to open.
+Vin +Vout
–Vin –Vout
RC
When not
using this
function
(always on)
Load
1-2.
Output voltage adjusting ter-
minal (TRM) (1.5-10W type)
Output voltage can be set to the values shown in the figure
below by connecting the TRM terminal to the -Vout termi-
nal.
When not using this function (always on), set the TRM ter-
minal to open.
Note that when the output voltage is set high by this func-
tion, derating of output current is necessary according to
the maximum power.
DIP/SMDmodels
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Model name Open
Connection to -Vout
Fig.
CC –xx03Sx–E 3.3V 3.6V 1
CC –xx05Sx–E 5V 6V 1
CC –xx12Sx–E 12V 15V 1
CC –xx12Dx–E ±12V ±15V 2
Fig.1
Fig.2
+Vin +Vout
TRM
–Vin –Vout
+Vin
–Vin –Vout
TRM
+Vout
3.3V
5V
12V
3.6V
6V
15V
+Vin +Vout
TRM
COM
–Vin –Vout
+Vin
–Vin –Vout
+Vout
Load
Load
Load
Load
TRM
COM
+12V
–12V
+15V
–15V
Load
Load
SIPmodels
Model name Model name
Connection to -Vout
Fig.
CC3–xx03SS–E 3.3V 3.67V 3
CC3–xx05SS–E 5V 6V 3
CC3–xx12SS–E 12V 15V 3
CC3–xx12DS–E ±12V ±15V 4
Fig.3
Fig.4
+Vin
+Vout
TRM
–Vin
–Vout
Load Load
+Vin
+Vout
TRM
–Vin
–Vout
3.3V,5V,V76.3V21 ,6V,15V
+Vin
+Vout
TRM
–Vin
–Vout
Load Load
COM
+Vin
+Vout
TRM
–Vin
–Vout
Load Load
COM
+12V –12V +15V –15V
1. Control functions/Protection functions/Connections
CC-E
・All specifications are subject to change without notice.
22
24V single output by making the COM terminal and TRM
terminal open. And output voltage can be set to 30V single
output by making the COM terminal open and connecting
the TRM terminal to the -Vout terminal.
models
Model name COM terminal
TRM terminal
Single output
Fig.
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Open Open
Open
Connection to -Vout
6.giF5.giF
+Vin
–Vin –Vout
+Vout
TRM
COM
24V
+Vin
–Vin –Vout
+Vout
TRM
COM
30V
Load
Load
models
TRM terminal
Single output
Fig.
Model name COM terminal
Open Open
Open
Connection to -Vout
8.giF7.giF
+Vin
+Vout
TRM
–Vin
–Vout
Load
COM
24V
+Vin
+Vout
TRM
–Vin
–Vout
Load
COM
30V
1-3. Output voltage adjusting func-
tion (adding external resistance)
(1.5-10W type)
Output voltage can be varied in the range shown in the fig-
ure below by connecting a resistance (Ra, Rb) between the
TRM terminal and the -Vout terminal or between the TRM
terminal and +Vout terminal.
Note that when the output voltage is set high, derating
of output current is necessary according to the maximum
power.
models
to to
to
to
to
to
to
to
Model name Fig. Fig.
Connection between
-Vout and Ra
Connection between
+Vout and Rb
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Calculating output voltage Vout (V) from connected resis-
tance Ra, Rb (kΩ)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 9.59/(32+Ra)
*2 Vout = 5.01 + 17.64/(17.8+Ra)
*3 Vout = 12.01 + 50.53/(16.9+Ra)
*4 Vout = 12.02 + 53.55/(18+Ra)
Adding a resistance Rb between TRM terminal and
wol egatlov tuptuo eht tes ot ,lanimret tuoV+
*5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb ≧ 62]
*6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb ≧ 160]
*7 Vout = 12.01 - 431.1/(57+Rb) [Rb ≧ 620]
*8 Vout = 12.02 - 968.5/(103+Rb) [Rb ≧ 1500]
Calculating connected resistance Ra, Rb (kΩ) from set out-
put voltage Vout (V)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Ra = 9.59/(Vout-3.3) - 32
*2 Ra = 17.64/(Vout-5.01) - 17.8
*3 Ra = 50.53/(Vout-12.01) - 16.9
*4 Ra = 53.55/(Vout-12.02) - 18
Adding a resistance Rb between TRM terminal and +Vout
wol egatlov tuptuo eht tes ot ,lanimret
*5 Rb = 15.53/(3.3-Vout) - 39.6
*6 Rb = 52.55/(5.01-Vout) - 31.8
*7 Rb = 431.1/(12.01-Vout) - 57
*8 Rb = 968.5/(12.02-Vout) - 103
01.giF9.giF
21.giF11.giF
Ra
–Vout
TRM
+Vout
3.3∼3.6V
5∼6V
12∼15V Rb
–Vout
TRM
+Vout
3.15∼3.3V
4.75∼5V
11.4∼12V
Ra
–Vout
TRM
+Vout
COM
Load
Load
+12∼+15V
–12∼–15V
Rb
–Vout
TRM
+Vout
COM
Load
Load
+11.4∼+12V
–11.4∼–12V
*1,*2, *3
*4
*5,*6, *7
*8
Load
Load
models
Model name Fig. Fig.
Connection between
-Vout and Ra
Connection between
+Vout and Rb
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
to to
to
to
to
to
to
to
Calculating output voltage Vout (V) from connected resis-
tance Ra, Rb (kΩ)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 1.04/(2.83+Ra)
*2 Vout = 5 + 12.75/(12.69+Ra)
*3 Vout = 12 + 48.4/(16.18+Ra)
*4 Vout = 12 + 54.7/(18+Ra)
Adding a resistance Rb between TRM terminal and
wol egatlov tuptuo eht tes ot ,lanimret tuoV+
*5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb ≧ 7.6]
*6 Vout = 5 - 12.78/(17.79+Rb) [Rb ≧ 33.3]
*7 Vout = 12 - 184.1/(35.54+Rb) [Rb ≧ 271.3]
*8 Vout = 12 -470.3/(61.75+Rb) [Rb ≧ 722.1]
For the ±12V output model,
CC-E
・All specifications are subject to change without notice.
23
Calculating connected resistance Ra, Rb (kΩ) from set out-
put voltage Vout (V)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Ra = 1.04/(Vout-3.3) - 2.83
*2 Ra = 12.75/(Vout-5) - 12.69
*3 Ra = 48.4/(Vout-12) - 16.18
*4 Ra = 54.7/(Vout-12) - 18
Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Rb = 1.69/(3.3-Vout) - 3.66
*6 Rb = 12.78/(5-Vout) - 17.79
*7 Rb = 184.1/(12-Vout) - 35.54
*8 Rb = 470.3/(12-Vout) - 61.75
41.giF31.giF
61.giF51.giF
+Vout
TRM
–Vout
Load Ra
3.3∼3.67V、5∼6V、12∼15V Load
Rb
+Vout
TRM
–Vout
3.15∼3.3V、4.75∼5V、11.4∼12V
+Vout
TRM
–Vout
Load Load
COM
Ra
+12∼+15V –12∼–15V
+Vout
TRM
–Vout
Load Load
COM
Rb
+11.4∼+12V
–11.4∼–12V
*1,*2, *3 *5, *6,*7
*4 *8
1-4. Over current protection
1.5-10W type
An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered. By removing the over current and shorted condi-
tions, the output voltage automatically resumes. Note that
if the over current status continues for 30 seconds or over,
the internal elements of the converter may be deteriorated
or damaged. The current value, from which it is judged as
an over current, is not to be lower than the nominal current
15/25W type
An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered and the converter is stopped and latched. The
output voltage does not automatically resume even after
removing the over current and shorted conditions.
To resume output voltage, restart input or reset remote on/
off.
The current value, from which it is judged as an over cur-
rent, is not to be lower than the nominal current value.
1-5. Over voltage protection
An over voltage protection function is not incorporated in
the model. Be careful if an external voltage over the nomi-
nal voltage is applied, damage may be caused.
1-6.
Low input voltage protection
This series is equipped with the low input voltage protec-
tion in order to prevent malfunction due to low input volt-
age. The converter stops operation if the input voltage
become lower than the set voltage. The set ranges are
shown in the table below.
Model name Input voltage range
Voltage range set for protection circuit
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
to to
to
to
to
to
to
to
to
to
to
to
1-7. Insulation withstand voltage
The insulation withstand voltage between input and output,
and between terminal and case, is AC500V.
1-8. Series/Parallel connections
Series connection
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
Load
Load
Parallel connection
Parallel connection is not applicable.
Serial connection is applicable by wiring as shown in the
figure below (left). If output voltage is not generated by this
connection, connect a Schottky barrier diode in which the
forward voltage is possibly low.
Also note that the Schottky barrier diode should have a
reverse voltage that is twice or over the value of the voltage
between +Vout and -Vout.
And the output current should be the same or lower than the
nominal current value, whichever is smaller in the convert-
ers.
The above setting value is fixed and cannot be adjusted
externally.
value. Due to fold back characteristics of OCP, the output
may not rise up steady with constant current load or induc-
tive load.
CC-E
・All specifications are subject to change without notice.
24
2-1.
Output ripple noise measurement method
The measured value of the converter noise may differ de-
pending on the measurement method. Measurement should
be conducted in a position close to the output terminal.
When connecting a prove, do not allow a loop to be config-
ured in order not to pick up flux.
As well, note that the spike voltage greatly differs depend-
ing on the ripple voltmeter and frequency band of the oscil-
loscope.
Our noise measurement is conducted by the wiring shown
in the figure below and in the frequency band of 50MHz.
+Vin
Vin Vout
Iin
+Vout
–Vin
–Vout
lout
1.5m
50Ω coaxial cable
50MHz
0.1µF
A
V
10mm 20mm
50MHz
V
A
Ripple
voltmeter
or
End-point: 50Ω+0.1µF
Oscilloscope
Load
2-2. Input ripple noise
This series is equipped with a built-in capacitor for input.
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
Load
Load
When the distance to the input of the converter from the
input power supply is long, attach a capacitor as close as
possible to the input terminal.
+Vin +Vout
–Vin –Vout
Load
When the distance to the input of the converter from the
input power supply is long, the impedance of the input line
can become high, causing high spike noise.
In this case, it is recommended to connect a capacitor as
close as possible to the input of the DC-DC converter.
2-3. Output ripple & noise
To reduce Output ripple & noise, connect a capacitor to
the output of the converter. In addition, reduction can be
enhanced if a π type filter is incorporated as shown in the
figure below. In this case, use of a coil with around 100µH
is recommended.
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
Load
Load
When the distance to the load from the output of the con-
verter is long, connect the capacitor as close as possible
to the load.
To reduce output spike noise, connect a ceramic capacitor
with around 1µF to the output of the converter.
+Vin +Vout
–Vin –Vout
1F
Load
2-4. Capacity of external capaci-
tor connected to output
Note that if a capacitor with capacity over the value shown
in the table below is connected to the output, or several
capacitors with low impedance are connected in parallel,
operation of the converter may become unstable.
Model name
Electrostatic capacitance (µF) max.
2. Noise reduction methods
However, by connecting a capacitor with around 10
µ
F,
input ripple noise and input return noise can be reduced.
CC-E
・All specifications are subject to change without notice.
25
3-1. Soldering conditions
●Soldering conditions
DIP models / SIP models
Observe the following conditions in soldering board.
Solder dip 260°C, 10s max., 1 time
Soldering copper 380°C, 3s max., 1 time/PIN
SMD models
Lead-free soldering / High-temperature reflow process
150˚C
180˚C
225˚C min.
245˚C max.
Surface temperature of parts
40 to 100s1 to 3˚C/s 1 to 4˚C/s
30 20s
1 to 5˚C/s
3-2. Cleaning method
Board cleaning after soldering is not recommended. How-
ever, the cleaning fluids and conditions shown in the table
below have been tested and proved to have no problem.
These fluids and conditions can be used.
Cleaning fluids and test conditions
Cleanthrough 750H
(1) Cleaning (shaking) at 60°C for 4 minutes
(2) Rinsing (shaking in water) at 60°C for 4 minutes
(3) Rinsing (shaking in water) at ordinary temperature -
40°C for 4 minutes
(4) Drying at 70°C for 6 minutes
Pine alpha ST100S
(1) Cleaning (shaking) at 60°C for 5 minutes
(2) Rinsing (shaking in water) at 30°C for 3 minutes
(3) Drying at 70°C for 6 minutes
Terpene Cleaner EC-7R
(1) Cleaning (shaking) at 60°C for 5 minutes
(2) Rinsing (shaking in IPA) at 30°C for 10 minutes
(3) Drying at 70°C for 6 minutes
Isopropyl alcohol
(1) Ultrasonic waves at 60°C for 1 minute
(2) Cool bath cleaning R.T. for 1 minute
(3) Vapor cleaning at 83°C for 1 minutes
Asahiklin AK-225AES
(1) Ultrasonic waves at 50°C for 2 minutes
(2) Cool bath cleaning R.T. for 2 minutes
3. Soldering conditions/Cleaning conditions
2-5. Common mode noise
For products other than with 10W, capacitors are not con-
nected between the primary GND and the secondary GND.
To reduce common mode noise, connect a capacitor with
around 1000pF between the primary GND and the second-
ary GND, as shown in the figure below.
In this case, note that if the capacitor that is connected is
too large, coupling capacitance between input and output
becomes large.
Also be careful about the withstand voltage of the capacitor
(500V or over is desirable with consideration of the insula-
tion withstand voltage).
+Vin +Vout
–Vin –Vout
Load
For products with 10W, capacitors with 1000pF are inter-
nally connected between primary and secondary.
2-6. Radiation noise
Radiation noise of the converter can be reduced by con-
necting the case terminal to the input or output GND ter-
minal. The effectiveness varies depending on the device.
Check it on the actual device.
Regarding wiring, use GND line and solid pattern for the
bottom of the converter as much as possible.
- SMD models are not equipped with case terminals.
The reflow must be 1 time only.
(Do not reflow with the on-board module on the motherboard underside.)