Cmv
User Manual: cmv NITRA Pneumatic Inserts
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Compact Modular Valves INSTALLATION AND MAINTENANCE INSTRUCTIONS, KEEP FOR FUTURE REFERENCE. For Technical Assistance Call 770-844-4200 Assembly And Pneumatic Testing: 1. 2. Align first valve with left end plate. Tighten the rear locking set screw with hex key 2.5 mm to a torque of 1.5 Nm (13 lb-in) 3. Tighten the front locking set screw with hex key 2.5 mm to a torque of 1.5 Nm (13 lb-in) 4. Continue in the same way to assemble the other valves as far as the end plate. Make sure that the contact fingers of each valve engages with the successive ones and with the relevant seat in end plate, verifying also that the gasket is in its seat. When complete it is necessary to perform a pneumatic test on the assembly to check general tightness. Plug the valve output fittings and connect the terminal input fittings marked with identification numbers 1, 11, X to the supply. The pressure used for the test must always be between 45-100 psi [3.1-6.9 bar]. Manual Controls: Locking Manual Override Port 2 or 4 pilot-assisted • Press the manual control in to operate valve then turn it clockwise 90 degrees to lock. • To unlock rotate the manual control 90 degrees counter clockwise and then release it. • The valve returns to the home position with the exception of CMV-B2L-XX which remains switched. Compact Modular Valves Rev. 1-20-17 General Wiring: Dual Solenoid Pin 25 Single Solenoid Single Solenoid red green/white brown blue/white white yellow/black green orange/white orange red/green yellow yellow/white light blue red/orange brown/white red/black white/red black/brown yellow/red black/orange red/blue white/black red/brown blue/black Pin 1 green/black Common LINK/ACT IN / OUT M12 CONNECTOR 1 = TD+ 2 = RD+ 3 = TD4 = RD2 OUT IN 3 NS 1 LINK/ACT MS 4 DETAIL A SCALE 2 : 1 SECOND INLET IF APPLICABLE 4 3 2 DETAIL B SCALE 2 : 1 1 POWER SUPPLY M8 CONNECTOR 1 = +24V BUS 2 = +24V VALVE 3 = GND 4 = GND EtherNet/IP enabled inlet plates: • Use 4-pole M12 cables for both In and Out Ethernet connections and a 4-pole M8 cable for power. • Each valve manifold assembly can have a maximum of 16 solenoids. • Solenoids from left to right (1 through 16) equal bits 0 through 15. i.e. Solenoid 1 will be bit 0. • Any number of valve manifold assemblies can be “daisy chained” together on the same network. A OUT P2 B IN P1 POWER SUPPLY EXHAUST INLET Mounting the Base: A. Top mount using (2) M4-0.7x45mm socket head cap screws (5.8 Nm [51 lb-in]). B. / C. Bottom or rear mounting using (2) M5-0.8 (length as needed), (12Nm [106 lb-in]). D. Face mounting using (2) M5-0.8 (length as needed), (12Nm [106 lb-in]). An opening for the pipes is needed in the plate. E. DIN rail mounting using 35mm DIN bracket (CMV-ACC04 (2 required) - hardware included). F. Side mounting using the blind end plate, and (4) M4-0.7 (length as needed), (5.8 Nm [51 lb-in]) threads on the side. Note: Other mounting positions not recommended. General Assembly Instructions: A B C D www.AutomationDirect.com - 3505 Hutchinson Rd., Cumming, GA 30040 - 1-800-633-0405 Fitting the DIN brackets (CMV-ACC04 - 2 required): Fix the brackets onto both end plates (A and B) using the screws supplied with the brackets (12Nm [106 lb-in]). Brackets can be positioned facing either direction as shown on C or D.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c011 79.156289, 2014/03/31-23:39:12 Create Date : 2017:02:24 13:32:48-05:00 Metadata Date : 2017:02:24 13:33:14-05:00 Modify Date : 2017:02:24 13:33:14-05:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:7c51aca0-0daf-4336-b3d0-069a7e5364de Original Document ID : xmp.did:9fe74061-604d-a546-8016-dee653dca92f Document ID : xmp.id:12f5f0d4-474f-e447-9c03-04f90ef89647 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:92e8d865-199f-054c-a292-ebe7527194cc Derived From Document ID : xmp.did:c64bbd6b-c247-7148-b754-0dc76c28cf46 Derived From Original Document ID: xmp.did:9fe74061-604d-a546-8016-dee653dca92f Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2017:02:24 13:32:48-05:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2014 (Windows)EXIF Metadata provided by EXIF.tools