CHROMA METER CR 400/410 400 Cr400 Catalog Eng

User Manual: 400

Open the PDF directly: View PDF PDF.
Page Count: 5

DownloadCHROMA METER CR-400/410 400 Cr400 Catalog Eng
Open PDF In BrowserView PDF
CHROMA METER

CR-400/410
25

CR-410
CR-400

Introducing the successor to the Konica Minolta CR-300/310,
our best-selling colorimeter globally accepted as the standard
in a wide range of industries.

CR-400

Measurement area Ø 8mm

CR-410

Measurement area Ø 50mm

CR-400

CR-410

Data Processor DP-400

The measuring head can perform
measurement alone.

Easy-to-understand the name on the buttons, ensure
smooth measurement and setting operations.

The measuring head is detachable from the data processor.
Now, you can take measurements directly with the head
alone. What's more, you can connect the measuring head
directly to a PC. Simply install our optional software, and
your PC can function as the data processor.

Achieves exceptional accuracy
Inter-instrument agreement : CR-400: 6E*ab within 0.6
CR-410: 6E*ab within 0.8
Repeatability : within 6E*ab 0.07

User-defined evaluation formulas
freely set up.
The CR-400 Series features a User Index function that
allows you to configure the evaluation formula and colorcalculation formula as desired. This feature is intended to
meet the needs of color-control applications in which
industry-specific or customized evaluation formulas are
used instead of the versatile color system and standard
evaluation formula such as L*a*b*.
(Settings can be configured via a PC with optional software installed.)

Abundant accessories applicable to
various materials.
A varied selection of accessories is available to
accommodate various types of targets including powder,
paste and opaque liquids.

User calibration function ensures higher accuracy.
(Settings can be configured with the data processor or via a PC with optional software
installed.)

Color difference tolerance can be set to perform
PASS/WARN/FAIL
(Settings can be configured with the data processor or via a PC with optional software
installed.)

Offers a wider range of color systems than the CR300/310 Series.
The measuring head alone can store up to 1,000
measurements. When the data processor is connected,
up to 2,000 measurements can be stored.(The measuring
head can store up to 100 color-difference target colors with
or without the data processor connected.)
Capable of displaying color-difference graphs that
provide a visual representation of the color difference.
(When connected to data processor)

Compact data processor incorporates a high-speed printer.
The compact, lightweight data processor is batteryoperated* and features a built-in high-speed printer. Its size
and weight are approximately one-half those of the
conventional DP-300 Series. In addition, the CR-400 Series
is designed with a detachable shoulder strap for easier
portability. *An AC adapter is included as a standard accessory.

Full data compatibility with the
CR-300/310 series
To ensure data compatibility, the CR-400 Series utilizes the
same illumination-viewing optical system as the
conventional CR-300/310 Series. As a result, those
upgrading from the preceding model can make full use of
their existing data.

A simple, cellular-phone-type text entry system is
provided for entering the names of color-difference
target colors and calibration channels.
(When connected to data processor)

Features a large, easy-to-see LCD with a built-in
backlight.
The LCD offers six user-selectable languages for the
display mode, including English and Japanese.
(When connected to data processor)

Can be powered with rechargeable batteries for reduced
operating costs.

Denotes a new feature not available with the previous CR-300/310 Series.

The CR-400/410 Series really shows its abilities in these applications.
When measuring
powders or pastes

When color control
is performed with
a customized
evaluation formula,
instead of the versatile
color system

W
d

U
y
U
-E
E
N

When a compact
colorimeter
is needed in the field

When measurements
need to be printed
on-site for labeling
of samples

T
p
li

Spec

System Diagram

Name
Model
Illumina

RS232C Cable(for PC)

CR-A102

Data Processor
DP-400

Detecto
Display
Light so
Measu
Minimum
Battery

Measuring Head

(includes one Roll Paper)

CR-410

CR-400

RS232C Cable
(Head-DP)

PC
(commercially available)

CR-A101

Shoulder Strap SS-01

Measure
Repeat
SpectraMagic NX
TM

Wrist Strap

AC Adapter

Roll Paper DP-A22
(five rolls)

CM-S100w

CR-A73

AAA Size
Battery (x4)

AA Size
Battery (x4)

CR-400 Utility
Software CR-S4w

Inter-in

Observ
Illumina
Display
Toleranc
Colorim
indexes

Langua
Protective Cap

CR-A72

Protective Cap

CR-A104

White Calibration
Plate CR-A43

White Calibration
Plate CR-A44

Hard Case

CR-A103

Data m
Color dif
Calibrat
Display
Interfac
Power

Glass Light
Projection Tube

Glass Light
Projection Tube

CR-A33a

(with convex glass)

CR-A33f

(with concave glass)

Light
Projection Tube

CR-A33c
(no disc)

Light
Projection Tube

CR-A33d

(with φ22mm disc)

Pivoting Base CR-A12
(includes CR-A33c)

Color Tiles

Granular-Materials
Attachment CR-A50
Glass Light-Projection
Tube CR-A33e

Standard accessories
Optional accessories

Optional Accessories

Size (W
Weight

Operat
humidit
Storage te
Other

∗1 indica

that s

Granular-Materials Attachment
CR-A50
With the Granular-Materials Attachment
CR-A50, the color of powders, pastes,
grains, and other granular substances can
be easily and accurately measured.

Glass Light-Projection Tube
CR-A33f (For CR-400) and CR-A33e (For CR-410)

Glass Light-Projection Tube CR-A33f and CR-A33e
have a glass plate at the tip and can be used for
measuring wet surfaces or for ensuring that
materials such as textiles are flat during measurements.

SpectraMagic NX
TM

Supports Windows® Vista/7/8.1/10

SpectraMagic NX enables you to perform comprehensive color inspection and analysis of
incoming raw materials, in process production, and outbound color critical goods and
materials in virtually any industry. With SpectraMagic NX you can insert digital images with
measured data. Measure samples in any of 8 universally accepted color spaces. Select from 16
illuminants, and up to 40 indices to determine specific color and appearance properties, such
as brightness, haze, yellowness, opacity and strength. You can even configure up to 8
customized color equations. Reports range from simple Pass/Fail to trend charts, histograms,
color plots, and spectral graphs. SpectraMagic NX comes with predefined templates, or you
can create your own templates. For illustrations and explanations to understanding color and
color measurement technology, there is a link to Konica Minolta's well known and respected
“Precise Color Communication”.
TM

TM

TM

Specifications
Color space

Index

Color
difference
equation
Observer
Illuminant
Graph
display

L*a*b*, L*C*h, Lab99, LCh99, XYZ, Hunter Lab,
Yxy, L*u'v', L*u*v*, Munsell, and their color
differences (excluding Munsell)
WI (CIE 1982, ASTM E313-73, Hunter, Berger,
Taube, Stensby, Ganz), Tint(Ganz), YI (ASTM
D1925-70, ASTM E313-73, ASTM E313-96,
DIN6167), WB (B ASTM E313-73), Standard
Depth (ISO 105.A06), RXRYRZ,
Gray scale(ISO 105.A05)
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00
(CIE 2000), ΔE99 (DIN99), ΔE (Hunter), CMC
(I:c), FMC-2, NBS 100, NBS 200
2 Standard Observer
C, D65
L*a*b* absolute value, ΔL*a*b* (color difference
distribution), Hunter Lab absolute value, Hunter
ΔLab (color difference distribution), Trend chart and
histogram of each color space and color
difference equation, Pseudo Color display

Pivoting Base CR-A12 (For CR-400)

Attaching the Pivoting Base CR-A12 to the
Measuring head of the CR-400 ensures greater
stability and accuracy in measurements LightProjection Tube CR-A33c is also included.

CR-400 Utility Software

To take measurements or change the
measurement parameters of the CR400/410 Series, you can control the
unit with a PC.
Measurement data can be transferred
directly to a Microsoft Excel® file by
means of the OLE function.

・ The hardware of the computer system to be used must meet or
exceed the greater of the recommended system requirements
for the compatible OS being used or the following specifications.

CPU: Pentium® III 600 MHz equivalent or faster
Memory: 128 MB or more (256 MB or more recommended)
Hard disk: 450 MB or more of free space for installation

Display resolution: 1,024 x 768 dots or more/ 16-bit colors or more
Other: DVD-ROM drive (required for installation); one free
USB port for protection key; one free port (serial port
or additional USB port) for connection to instrument
when connecting via cable (or USB port for USB
Bluetooth® adapter when using a USB Bluetooth®
adapter for performing communication with CM-700d
or CM-600d via Bluetooth®); Internet Explorer Version.
5.01 or later.

Langua
Data m

Color diff

Calibrat

Page fu
Display
Printer
Statisti
Automa

Interfac
Power

(Excel® 97/2000/2002/2007 is required to use the Excel® transfer function.)

Calibration data and color-difference
reference color data can be uploaded
or modified.

Size (W
Weight
Operat
humidit
Storage te
Other

∗2 indic

System requirements
OS:

System requirements
OS: Windows® Vista Business 32-bit, 64-bit
Windows® 7 Professional 32-bit, 64-bit
Windows® 8.1 Pro 32-bit, 64-bit
Windows® 10 Pro 32-bit, 64-bit

CR-S4w

Name
Model
Display
Measur
Minimum
Battery
Illumina
Display
Toleran
Colorim
indexes

CPU:
Memory:
Hard disk:
Display resolution:

Windows® 7 Professional 32-bit, 64-bit
Windows® 8.1 Pro 32-bit, 64-bit
Windows® 10 Pro 32-bit, 64-bit

・ The hardware of the computer system to be
used must meet or exceed the greater of the
recommended system requirements for the
compatible OS being used or the following
specifications.

Pentium® 166MHz or higher
32MB or higher
100MB or more free space
VGA (640× 480) or higher

・ Windows® is a trademark or registered trademark of Microsoft
Corporation in the USA and other countries.
・ Pentium® is a trademark of Intel Corporation in the USA and
other countries.
・ Bluetooth® is a registered trademark of Bluetooth SIG, Inc. and
is used under license agreement.

©2002

Dimensions (Units: mm)

Measuring Head CR-400

Measuring Head CR-410

102

63

244
67.5

40.2
32
32

Data Processor DP-400

255

as
CR uring
H
-4
00 ead
Me
as
u
r
CR ing
H
-4
10 ead
Da
ta P
r
o
c
DP
e
-4 ssor
00

Standard/Optional
accessories

Me

∗

that some of the function are not available when the measuring head is not connected.

102

217

63

100

Name
Chroma Meter Measuring Head
Model
CR-400 Head
CR-410Head
Illumination/viewing system Diffuse illumination/0 viewing angle
Wide-area illumination/0 viewing angle
(Specular component included/Conforms (Specular component included)
to JIS Z 8722 condition c standard.)
Detector
Silicone photo cells (6)
Display range
Y: 0.01 to 160.00% (reflectance)
Light source
Pulsed xenon lamp
Measurement time
1 seconds.
Minimum measurement interval 3 seconds.
Battery performance
Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area φ8/φ11
φ50/φ53
Repeatability
Within ΔE*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter-instrument
ΔE*ab: within 0.6
ΔE*ab: within 0.8
agreement
Average of 12 BCRA series II colors
Observer
2 degrees Closely matches CIE 1931 Standard Observers: ( x2λ, yλ, zλ)
Illuminant ∗1
C, D65
Display ∗1
Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment ∗1
Color difference tolerance (box tolerance and elliptical tolerance)
XYZ, Y x y, L∗a∗b∗, Hunter Lab, L∗C∗h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
Colorimetric data/
indexes
LCh99, CIE2000, CIE WI•Tw (only illuminant D 65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages
Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Data memory
1,000 (measuring head and data processor save different data)
Color difference target colors 100
Calibration channels *1
20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface
RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power
4 AAA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D)
102 x 217 x 63 mm
102 x 244 x 63 mm
Weight
Approx. 550g
Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operation temperature/ 0 to 40 C, relative humidity 85% or less (at 35 C) with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation
Storage temperature/humidity range -20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation
Other
LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
∗1 indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,

73

Specifications

Color Data Software CM-S100w
Data Processor
SpectraMagic NX
DP-400
CR-400 Utility Software
Y : 0.01 to 160.00% (reflectance)
CR-S4w
1 Seconds.
White Calibration Plate
3 Seconds.
CR-A43
White Calibration Plate
Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
CR-A44
C, D65
Protective Cap
Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
CR-A72
Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Protective Cap
XYZ, Y x y, L∗a∗b∗, Hunter Lab, L∗C∗h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
CR-A104
LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
RS-232C Cable
CR-A101(Head-DP)
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
RS-232C Cable
User index (up to six registered in the Measuring Head can be used)
CR-A102(for PC)
Languages
Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
AC Adapter
Data memory
Max. 2,000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Wrist Strap
Color difference target colors ∗2 Only for the operating function (100 pieces of data when the measuring head is connected; input of
CR-A73
Shoulder Strap
measurement values or numeric) (independent of page function)
SS-01
∗
Calibration channels 2
Only for the operating function (20 channels when the measuring head is connected)
Hard Case
(ch00: white calibration; ch01 to ch19: user calibration)
CR-A103
Page function
100 pages
Roll Paper (one roll)
Display
Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer
384 dot line thermal printer (can also print graphs) Automatically prints out all measurement results (can be set not to print)
Roll Paper
DP-A22(five rolls)
Statistical function
Maximum, minimum, average, and standard deviation
Automatic measurement ∗2 Date and time display: year, month, day, hour, minute
4 AA Size Batteries
Timer: 3seconds. to 99 minutes.
4 AAA Size Batteries
(Some measurement modes require more than 3 seconds.)
Interface
RS-232C compliant
Baud rate (bps) : 19,200 fixed (when connected to PC)
Glass Light-Projection Tube
When measuring head is connected baud rate is automatically set to that of the measurement head
CR-A33a/f
Light-Projection Tube
Power
4 AA size alkaline or Ni-MH batteries,
CR-A33c/d
AC Adapter AC120V 50-60Hz (for N.America and Japan)
Glass Light-Projection Tube
AC230V 50-60Hz (for worldwide except N.America)
CR-A33e
Size (W x H x D)
100 x 73 x 255 mm
Granular-Materials Attachment
Weight
Approx. 600g (not including batteries and paper)
CR-A50
Operation temperature/
0 to 40 C, relative humidity 85% or less (at 35 C) with no condensation
Pivoting Base
CR-A12
Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation
humidity range
Storage temperature/humidity range -20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation
Color Tiles
Other
User calibration function (multi-calibration/manual calibration) ∗2, Measurements for automatic average
Standard accessory
function, Print ON/OFF function. CR-400 measurement data import function ∗2, All color space print ON/OFF
Optional accessory
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
∗2 indicates that part of or all functions are not available when the measurement head is not connected.
The specifications and appearance shown herein are subject to change without notice.

Name
Model
Display range
Measurement time ∗2
Minimum measurement interval ∗2
Battery performance
Illuminant
Display
Tolerance judgment ∗2
Colorimetric data/
indexes

TM

∗

SAFETY PRECAUTIONS

©2002-2017 KONICA MINOLTA, INC.

For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock.

9242-4889-11 BHBPK

Printed in Japan



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c320 44.284297, Sun Apr 15 2007 17:19:00
Instance ID                     : uuid:24841874-b11b-4151-8221-df1b271960d7
Document ID                     : adobe:docid:indd:e14fe234-515e-11e0-810e-b6005cc023d3
Rendition Class                 : proof:pdf
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:ba8bef62-3970-11e4-bcc1-000a95950262, uuid:c2c561f9-4f82-11e0-a820-000a959442e8, uuid:c2c561f9-4f82-11e0-a820-000a959442e8, uuid:ba8bef62-3970-11e4-bcc1-000a95950262, uuid:ba8bef62-3970-11e4-bcc1-000a95950262
Manifest Reference Document ID  : uuid:20A949DD3B3C11E49F89954674B844B8, uuid:c2c55ad0-4f82-11e0-a820-000a959442e8, uuid:c2c55ad0-4f82-11e0-a820-000a959442e8, uuid:20A949DD3B3C11E49F89954674B844B8, uuid:20A949DD3B3C11E49F89954674B844B8
Create Date                     : 2014:09:11 14:01:49+09:00
Modify Date                     : 2017:01:19 16:04:07+09:00
Metadata Date                   : 2017:01:19 16:04:07+09:00
Creator Tool                    : Adobe InDesign CS2_J (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10477 bytes, use -b option to extract)
Format                          : application/pdf
Creator                         : KONICA MINOLTA, INC.
Title                           : CHROMA METER CR-400/410
Description                     : ..
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Trapped                         : False
Item 0020code                   : 9242-4889-11
Print 0020code                  : BHBPK
Page Count                      : 5
Page Layout                     : SinglePage
Print Code                      : BHBPK
Subject                         : ..
Author                          : KONICA MINOLTA, INC.
Item Code                       : 9242-4889-11
EXIF Metadata provided by EXIF.tools

Navigation menu